[email protected]
800-683-8353
ROMII/ROMIII
Commercial grade reverse osmosis systems
for the home
The same commercial quality that makes Everpure® the overwhelming choice for water treatment in restaurants is also available for your
home. Everpure’s reverse osmosis systems deliver RO-quality water that reduces contaminants such asarsenic, lead, copper, sodium
nitrate/nitrite, fluoride, cysts and TDS. The ROM III provides added protection by reducing MTBE and volatile organic chemicals.
It’s water you can trust
the pure solution
Our products polish water to premium quality so that water is sparkling and free
of unwanted tastes and odors. You’ll taste the difference in every sip and
everything made with water will taste better, too.
the convenient solution
Everpure systems are easily installed using common household tools. Our
systems mount under your sink and are plumbed to a separate filter faucet.
And cartridge replacement is easy, too — just like changing a light bulb.
the practical solution
At only pennies per gallon, this system is less expensive per glass than bottled
water or other drinking water systems and provides about a year’s supply of
water, depending on the size of your family and the amount of water you drink.
the advanced solution
The ROM water processors provide maximum protection of your drinking water
against contaminants by blending up to three powerful technologies.
ROM II
The ROM II utilizes the S-101 carbon block prefilter to prepare the
water for the TFC cartridge. This prefilter reduces chlorine tastes
and odors and other particulate matter in the water. The TFC (thin
film composite) reverse osmosis cartridge then filters the water
down to .00001 microns. This method of filtration reduces
contaminants such as arsenic, fluoride, sodium, nitrates and TDS.
ROM III
The ROM III employs the same water filtering capabilities as the
ROM II, but adds another level of protection with the VOC #1
cartridge. The VOC #1 post filter reduces volitile organic
chemicals and MTBE that may exist in the water even after coming
from the TFC cartridge.
[email protected]
ROM II post filter GAC helps
reduce VOC’s and MTBE.
ROM II/III prefilter carbon block
reduces chlorine taste and odor
and particulate matter.
Everpure’s signature metal
canister delivers commercial
grade durability and quality
and protects the filter system
from splitting or bursting. It’s
lined with a food-grade
polymer that prevents the
water from coming in contact
with the metal.
800-683-8353
reverse osmosis process
Built-in water shut off to
storage tank.
Advanced TFC RO
membrane provides
92-94% reduction of TDS.
Quick change disposable
cartridges have metal walls
to resist water pressure
surges which are known to
crack or split some plastic
filter housings.
www.FridgeFilters.com
[email protected]
800-683-8353
product specifications
ROMII/ROMIII
Commercial grade reverse osmosis systems
for the home
ROM II Reverse Osmosis Drinking Water System ( EV9273-85)
ROM III Reverse Osmosis Drinking Water System (EV9273-86)
S-101 Prefilter Cartridge “A” (EV9273-77)
TFC RO Cartridge “B” (EV9273-70)
ROM III VOC #1 Cartridge “C” (EV9273-79)
Features:
This drinking water system must be
maintained according to the
manufacturer's instructions, including
replacement of filter cartridges. The
substances reduced or removed by this
system are not necessarily in your water.
Read the performance data sheet.
> Finely polishes treated water to premium quality for drinking and cooking.
> Reduces chlorine taste and odor.
> Reduces dirt, rust, asbestos fibers, and other particulates such as oxidized iron, manganese, and
sulfides.
> Reduces parasitic protozoan cysts such as Giardia, Entamoeba, and Cryptosporidium.
> Controls even extreme levels of common “off” tastes and odors, including those which are earthy,
moldy, and fishy.
> Reduces lead to below the Federal Action Level.
> Effectively reduces Volatile Organic Chemicals (VOCs), including Trihalomethanes (THMs).
> Effectively reduces methyl tertiary-butyl ether (MTBE).
> Inhibits limescale build-up in water-using applications.
General Installation/Operation/Maintenance Requirements:
> It is recommended that before purchasing a water treatment unit, you have your water tested to
determine your actual treatment needs.
> Space required: 12” wide x 17” high x 4” deep (30 x 43 x 10 cm), plus an additional 3 inches of
clear space under unit for cartridge change.
> Install vertically with cartridges hanging down.
> Use minimum length of tubing possible.
> Flush all cartridges,“A”, “B” and “C” per Installation and Use Manual provided with unit.
> S-101 Prefilter Cartridge “A” and VOC #1 Organics Cartridge “C” should be changed every 6
months. Properly maintained, TFC RO Cartridge “B” will last 2-3 years under average water
conditions. It is not possible to be specific about gallonage limits because turbidity and other aspects
of water quality are unpredictable.
> A separate drinking water faucet is required.
flow rate
Controlled at 0.5 gal./min. (1.9 L/min.)
minimum temperature
40-100° F (2-38° C) cold water use only
minimum pressure
40 psig. (280 kPa)
maximum pressure
125 psig. (860 kPa)
nominal production rate*
14.4 gal/day (54 Lpd)
* this may vary depending on specific water conditions
everpure warranty
Everpure Drinking Water Systems are
This system has been tested by Everpure for the reduction of the substances listed below.
Influent Challenge Max. Permissible Product
Substance
Concentration
Water Concentration
Arsenic
0.30 mg/L ± 10%
0.025 mg/L
Barium
10.0 mg/L ± 10%
2.0 mg/L
Cadmium
0.03 mg/L ± 10%
0.005 mg/L
Chromium (Hexavalent)
0.3 mg/L ± 10%
0.1 mg/L
Chromium (Trivalent)
0.3 mg/L ± 10%
0.1 mg/L
Copper
3.0 mg/L ± 10%
1.3 mg/L
Fluoride
8.0 mg/L ± 10%
1.5 mg/L
Lead
0.15 mg/L ± 10%
0.010 mg/L
Nitrate plus Nitrite (both as N) 30.0 mg/L ± 10%
10.0 mg/L
Nitrate(as N)
27.0 mg/L ± 10%
10.0 mg/L
Nitrite(as N)
3.0 mg/L ± 10%
1.0 mg/L
Selenium
0.10 mg/L ± 10%
0.05 mg/L
Radium 226/228
25 pCi/L ± 10%
5 p/Ci/L
Total Dissolved Solids
750 mg/L ± 40 ug/L
187 mg/L
Cyst
Minimum 50,000/L
MTBE*
0.015 mg/L ± 20%
0.005 mg/L
Chloroform
0.30 mg/L
0.15 mg/L
VOCs*
265 ppb
10 ppb
Reduction
Requirements
99.95%
Minimum
Reduction
96.6%
90.0%
90.0%
86.6%
85.7%
96.5%
89.9%
97%
Average
Reduction
98.0%
90.0%
96.4%
86.6%
85.7%
99.2%
95.2%
98.1%
74.3%
68.3%
93.0%
80.0%
92.4%
99.99%
77.8%
95.0%
96.0%
80.4%
75.8%
96.8%
80.0%
94.6%
99.99%
92.1%
99.0%
99.0%
warranted to be free of defects for a full
twelve (12) months after purchase. A
detailed warranty statement is provided
with each system.
Actual system performance may vary depending on water pressure, water temperature and other substances which may be found in water.
Everpure, Micro-Pure and the silver canister color are registered trademarks of Everpure, LLC © 2008
®
[email protected]
®
800-683-8353
www.FridgeFilters.com
">