Tranquility® 20 (TS) Series Submittal Data Models TSD/H/V 006 - 070 60Hz - HFC-410A English Language/I-P Units SUBMITTAL DATA - I-P UNITS Unit Designation: Job Name: Architect: Engineer: Contractor: PERFORMANCE DATA Cooling Capacity: Btuh EER: Rev.: 23 October, 2015 Heating Capacity: Btuh COP: Ambient Air Temp: °F Entering Water Temp (Clg): °F Entering Air Temp (Clg): °F Entering Water Temp (Htg): °F Entering Air Temp (Htg): °F Airflow: CFM Fan Speed or Motor/RPM/Turns: Operating Weight: (lb) ELECTRICAL DATA Power Supply: Volts Phase Minimum Circuit Ampacity: ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. *LC377* LC377 Rev.:23 October,2015 Maximum Overcurrent Protection: Hz Tranquility® 20 (TS) Series Submittal Data Models TSD/H/V 006 - 070 60Hz - HFC-410A English Language/S-I Units SUBMITTAL DATA - S-I UNITS Unit Designation: Job Name: Architect: Engineer: Contractor: PERFORMANCE DATA Cooling Capacity: kW EER: Rev.: 23 October, 2015 Heating Capacity: kW COP: Ambient Air Temp: °C Entering Water Temp (Clg): °C Entering Air Temp (Clg): °C Entering Water Temp (Htg): °C Entering Air Temp (Htg): °C Airflow: l/s Fan Speed or Motor/RPM/Turns: Operating Weight: (kg) ELECTRICAL DATA Power Supply: Volts Phase Minimum Circuit Ampacity: ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. *LC377* LC377 Rev.: :23 October,2015 Maximum Overcurrent Protection: Hz TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Table of Contents *Page Number Unit Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 TS Series Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Performance Data – AHRI/ASHRAE/ISO 13256-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Performance Data – Selection Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Performance Data – TS H/V 006A (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Performance Data – TS H/V 009B (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Performance Data – TS H/V 012A (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Performance Data – TS H/V/D 018B (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Performance Data – TS H/V/D 018B (ECM Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Performance Data – TS H/V/D 024 (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Performance Data – TS H/V/D 024 (ECM Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Performance Data – TS H/V/D 030 (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Performance Data – TS H/V/D 030 (ECM Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Performance Data – TS H/V/D 036 (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Performance Data – TS H/V/D 036 (ECM Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Performance Data – TS H/V/D 042 (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Performance Data – TS H/V/D 042 (ECM Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Performance Data – TS H/V/D 048 (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Performance Data – TS H/V/D 048 (ECM Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Performance Data – TS H/V/D 060 (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Performance Data – TS H/V/D 060 (ECM Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Performance Data – TS H/V/D 070 (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Performance Data – TS H/V/D 070 (ECM Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Air Flow Correction Table - Units with PSC Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Air Flow Correction Table - Units with ECM Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Entering Air Correction Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Correction Tables - Antifreeze and Water Pressure Drop Adder for Options . . . . . . . . . . . . . 32 Blower Performance Data – Standard Unit - No Reheat (PSC Motor) . . . . . . . . . . . . . . . . . . . 33 Blower Performance Data – Units with ClimaDry® (PSC Motor) . . . . . . . . . . . . . . . . . . . . . . . . 34 ECM Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Blower Performance Data – (ECM Motor) - Standard Unit - No Reheat . . . . . . . . . . . . . . . . . . 38 ClimaDry® II Option - Benefits and Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 ClimaDry® II Option - Sequence of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 TS - Horizontal – Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 TS - Horizontal Service Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 TS - Vertical Upflow – Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 TS - Vertical Service Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 TS - Vertical Downflow – Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Corner Weights for TSH Series Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Electrical Data – PSC Motor & ClimaDry® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Electrical Data – High Static PSC Motor & ClimaDry® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Electrical Data – ECM Motor & ClimaDry® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Electrical Data – PSC Motor & Secondary Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Electrical Data – High Static PSC Motor & Secondary Pump . . . . . . . . . . . . . . . . . . . . . . . . . 57 Electrical Data – ECM Motor & Secondary Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 TS Series Wiring Diagram Matrix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Typical Wiring Diagram – Single Phase TS Units with CXM Controller . . . . . . . . . . . . . . . . . . . 60 Typical Wiring Diagram – Three Phase TS Units with DXM Controller . . . . . . . . . . . . . . . . . . . . 61 Typical Wiring Diagram – Three Phase TS Units with CXM Controller and ECM Blower . . . . . . . 62 Typical Wiring Diagram – Single Phase TS Units with CXM, MPC, and ECM Controller . . . . . . . . 63 Typical Wiring Diagram – Single Phase TS Units with ClimaDry® II and ECM Blower . . . . . . . . . 64 Engineering Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Revision Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 *Document page number is shown next to part number (e.g. LC377 - 3 = page 3). Since not all pages are typically used in the submittals process, the page number in the lower right corner can still be used (page ____of_____). ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 3 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Unit Features THE TRANQUILITY® 20 SINGLE-STAGE (TS) SERIES UNIT FEATURES The award winning Tranquility Series raises the bar for water-source heat pump efficiencies, features and application flexibility. Not only does the Tranquility® 20 far exceed ASHRAE 90.1 efficiencies, but it also uses EarthPure® (HFC-410A) zero ozone depletion refrigerant, making it an extremely environmentally-friendly option. Tranquility® 20 is eligible for additional LEED® (Leadership in Energy and Environmental Design) points because of the “green” technology design. • • • • ® Available in sizes 1/2 tons (1.76 kW) through 6 tons (21.1 kW) with multiple cabinet options (vertical upflow, vertical downflow and horizontal) the Tranquility® 20 offers a wide range of units for most any installation. The Tranquility® 20 has an extended range refrigerant circuit, capable of ground loop (geothermal) applications as well as water loop (boilertower) applications. Standard features are many. Copeland scroll compressors, microprocessor controls, galvanized steel cabinet, polyester powder coat paint, stainless steel drain pan and foil-backed air handler insulation are just some of the features of the Tranquility® 20 Series. ClimateMaster’s exclusive double isolation compressor mounting system makes the Tranquility® 20 the quietest unit on the market. Compressors are mounted on specially engineered sound tested EPDM grommets to a heavy gauge mounting plate, which is then isolated from the cabinet base with rubber grommets for maximized vibration/sound attenuation. The unique low profile slanted control box makes installing and maintaining the unit easier than any other water-source heat pump currently in production. • • • • • • • • • • • • • • • • • Sizes 006 (1/2 ton, 1.76 kW) through 070 (6 tons, 21.1 kW) EarthPure® (HFC-410A) refrigerant Exceeds ASHRAE 90.1 efficiencies Galvanized steel construction with attractive black mat polyester powder coat paint and silver accents Stainless steel drain pan Foil-backed insulation in air handler section Unique double isolation compressor mounting with vibration isolation for quiet operation Insulated divider and separate compressor/air handler compartments Copeland scroll compressors TXV metering device Extended range (20 to 120°F, -6.7 to 48.9°C) operation Microprocessor controls standard (optional DXM and/or DDC controls) LonWorks, BACnet, Modbus and Johnson N2 compatibility options for DDC controls Field convertible discharge air arrangement for horizontal units High static blowers available ECM variable speed fan motor available Low profile slanted control box for easy access Flush securely-mounted corner post water connections (no backup wrench required) Unit Performance Sentinel performance monitoring system Eight Safeties Standard Wide variety of options including ClimaDry® modulating reheat, coated air coils and internal pumps Options such as ECM variable speed fan motor, coated air coil, DDC controls, internal pump and high efficiency MERV 11 two-inch (51mm) air filters allow customized design solutions. Optional high static fan motors help overcome some of the challenges associated with ductwork for retrofit installations. The Tranquility® 20 (TS) Series Water-Source Heat Pumps are designed to meet the challenges of today’s HVAC demands with one of the most innovative products available on the market. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 4 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Selection Procedure Reference Calculations Heating Cooling LWT = EWT - HE GPM x 500 LWT = EWT + LAT = EAT + HC CFM x1.08 LAT (DB) = EAT (DB) - HR GPM x 500 LC = TC - SC SC CFM x1.08 S/T = SC TC Legend and Glossary of Abbreviations BTUH = BTU( British Thermal Unit) per hour CFM = airflow, cubic feet/minute COP = coefficient of performance = BTUH output/BTUH input DB = dry bulb temperature °F EAT = entering air temperature, Fahrenheit (dry bulb/wet bulb) EER = energy efficiency ratio = BTUH output/Watt input MPT = male pipe thread ESP = external static pressure (inches w.g.) EWT = entering water temperature GPM = water flow in U.S. gallons/minute HE = total heat of extraction, BTUH HC = air heating capacity, BTUH HR = total heat of rejection, BTUH HWC FPT KW LAT LC LWT MBTUH S/T SC TC WB WPD = hot water generator (desuperheater) capacity, Mbtuh = female pipe thread = total power unit input, kilowatts = leaving air temperature, °F = latent cooling capacity, BTUH = leaving water temperature, °F = 1000 BTU per hour = sensible to total cooling ratio = sensible cooling capacity, BTUH = total cooling capacity, BTUH = wet bulb temperature °F = waterside pressure drop (psi & ft. of hd.) Conversion Table - to convert inch-pound (English) to S-I (Metric) Air Flow Water Flow Ext Static Pressure Water Pressure Drop Airflow (L/s) = CFM x 0.472 Water Flow (L/s) = gpm x 0.0631 ESP (Pa) = ESP (in of wg) x 249 PD (kPa) = PD (ft of hd) x 2.99 ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 5 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Selection Procedure Step 1 Determine the actual heating and cooling loads at the desired dry bulb and wet bulb conditions. Step 2 Obtain the following design parameters: Entering water temperature, water flow rate in GPM, air flow in CFM, water flow pressure drop and design wet and dry bulb temperatures. Air flow CFM should be between 300 and 450 CFM per ton. Unit water pressure drop should be kept as close as possible to each other to make water balancing easier. Go to the appropriate tables and find the proper indicated water flow and water temperature. Step 3 Select a unit based on total and sensible cooling conditions. Select a unit which is closest to, but no larger than, the actual cooling load. Step 4 Enter tables at the design water flow and water temperature. Read the total and sensible cooling capacities (Note: interpolation is permissible, extrapolation is not). Step 5 Read the heating capacity. If it exceeds the design criteria it is acceptable. It is quite normal for water source heat pumps to be selected on cooling capacity only since the heating output is usually greater than the cooling capacity. Step 6 Determine the correction factors associated with the variable factors of dry bulb and wet bulb. Corrected Total Cooling = tabulated total cooling x wet bulb correction. Corrected Sensible Cooling = tabulated sensible cooling x wet/dry bulb correction. Step 7 Compare the corrected capacities to the load requirements. Normally if the capacities are within 10% of the loads, the equipment is acceptable. It is better to undersize than oversize, as undersizing improves humidity control, reduces sound levels and extends the life of the equipment. Step 8 When completed, calculate water temperature rise and assess the selection. If the units selected are not within 10% of the load calculations, then review what effect changing the GPM, water temperature and/or air flow and air temperature would have on the corrected capacities. If the desired capacity cannot be achieved, select the next larger or smaller unit and repeat the procedure. Remember, when in doubt, undersize slightly for best performance. Example Equipment Selection For Cooling Step 1 Load Determination: Assume we have determined that the appropriate cooling load at the desired dry bulb 80°F and wet bulb 65°F conditions is as follows: Total Cooling...................................................23,000 BTUH Sensible Cooling.............................................17,000 BTUH Entering Air Temp.......80°F Dry Bulb / 65°F Wet Bulb Step 2 Design Conditions: Similarly, we have also obtained the following design parameters: Entering Water Temp....................................................90°F Water Flow (Based upon 10°F rise in temp.) .........6.0 GPM Air Flow...................................................................690 CFM Step 3, 4 & 5 HP Selection: After making our preliminary selection (TS024), we enter the tables at design water flow and water temperature and read Total Cooling, Sens. Cooling and Heat of Rej. capacities: Total Cooling...................................................25,200 BTUH Sensible Cooling.............................................18,400 BTUH Heat of Rejection.............................................31,100 BTUH Step 6 & 7 Entering Air and Airflow Corrections: Next, we determine our correction factors. Table Ent Air Air Flow Corrected Corrected Total Cooling = 25,200 x 0.9705 x 0.9724 = 23,782 Corrected Sens Cooling = 18,400 x 1.0809 x 0.8733 = 17,368 Corrected Heat of Reject = 31,100 x 0.9757 x 0.9728 = 29,519 Step 8 Water Temperature Rise Calculation & Assessment: Actual Temperature Rise..............................................9.8°F When we compare the Corrected Total Cooling and Corrected Sensible Cooling figures with our load requirements stated in Step 1, we discover that our selection is within +10% of our sensible load requirement. Furthermore, we see that our Corrected Total Cooling figure is within 1,000 Btuh of the actual indicated load. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 6 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P TS Series Nomenclature 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 TS V 0 2 4 A G C 3 0 C L T S Model Type Standard TS = Tranquility® 20 Single Stage Scroll (Rotary: Size 006-012) S = Standard Supply Air & Motor Option Configuration Option T D B S *V *U *Y *Z *K *N *P *W V = Vertical Upflow H = Horizontal D = Vertical Downflow Unit Size 006 - E,G 009 - E,G 012 - E,G 018 - E,G 024 - E,F,G,H 030 - E,F,G,H 036 - E,F,G,H 042 - E,F,G,H,N 048 - E,F,G,H,N 060 - E,F,G,H,N 070 - F,G,H,N Revision Level A = Current Revision Sizes 006-012 B = Current Revision Sizes 018 C = Current Revision Sizes 024-070 AVAILABLE VOLTAGES Voltage G = 208/230/60/1 E = 265/60/1 H = 208/230/60/3 F = 460/60/3 N = 575/60/3 * N/A for Sizes 006-012 Return Air L = Left Return R = Right Return Heat Exchanger Options Controls Control CXM DXM CXM w/LON DXM w/LON CXM w/MPC DXM w/MPC w/o Disconnect C D L M N P Supply Configuration Motor Top TSV PSC Down TSD PSC Back TSH PSC Straight TSH PSC Top TSV PSC Hi Static PSC Hi Static Down TSD PSC Hi Static Back TSH PSC Hi Static Straight TSH Top TSV ECM Down TSD ECM Back TSH ECM Straight TSH ECM w/ Disconnect A B E K R S Tin Plated Air Coil / Microchannel Air Coil* Cupro-Nickel Copper Cupro-Nickel N A J P D F Non Coated Air Coil Standard ClimaDry® Reheat Copper C E Motorized Valve T S U W ClimaDry® reheat coil not coated *Microchannel On Sizes 024-048 Cabinet OPTION RANGE 1 A J K 2 C L M 3 E N P 4 G R S ULTRA QUIET NO YES NO YES 1” FILTER 2” FILTER 1” FILTER 2” FILTER RAIL RAIL FRAME FRAME YES NO NO YES NO NO YES NO NO YES YES NO NO YES NO YES NO NO NO YES YES NO NO YES NO YES NO NO NO YES NO YES NO YES NO NO YES YES NO NO Water Circuit Options 0 = None 2 = HWG (Coil Only) 5 = Secondary Circulating Pump 6 = HWG (Coil Only) w/Auto Flow Regulator 2.5 GPM/Ton 7 = HWG (Coil Only) w/Auto Flow Regulator 3.0 GPM/Ton 8 = Auto Flow Regulator 2.5 GPM/Ton 9 = Auto Flow Regulator 3.0 GPM/Ton ClimaDry® II Option Notes: 1. Unit must have DXM control option. 460 volt unit units require a four wire power supply with neutral. 2. ClimaDry® II may not be combined with motorized water valve, internal secondary circulating pump, or automatic flow regulator options. 3. Unit minimum entering air temperature while in the dehumidification, cooling, or continuous fan modes is 65ºF DB/55ºF WB. Operation below this minimum may result in nuisance faults. 4. A thermostat with dehumidification mode or thermostat and separate humidistat/dehumidistat is required for activation and control of ClimaDry® II. 5. Downflow and 575 volt units are not eligible for ClimaDry® II ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 7 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – AHRI/ASHRAE/ISO 13256-1 ASHRAE/AHRI/ISO 13256-1. English (I-P) Units Water Loop Heat Pump Model Fan Motor Cooling 86°F Capacity Btuh EER Btuh/W Ground Water Heat Pump Heating 68°F Capacity Btuh COP Cooling 59°F Capacity Btuh EER Btuh/W Ground Loop Heat Pump Heating 50°F Capacity Btuh COP Cooling 77°F Capacity Btuh EER Btuh/W Heating 32°F Capacity Btuh COP TSH/V006 PSC 6,300 15.7 8,000 5.4 7,400 25.5 6,300 4.4 6,700 18.5 4,800 3.4 TSH/V009 PSC 9,300 15.3 11,100 4.8 11,100 25.2 9,400 4.3 10,000 18.1 7,100 3.4 TSH/V012 PSC 11,700 15.4 13,800 4.5 13,300 24.6 11,800 4.0 12,300 18.1 9,500 3.5 TSH/V/D 018 PSC 18,600 15.0 23,000 5.2 21,300 24.8 18,600 4.5 19,500 18.4 14,500 3.6 ECM 19,200 16.5 23,300 5.9 22,100 26.3 18,900 4.9 20,200 19.4 14,500 3.9 PSC 23,800 16.9 30,800 5.9 26,500 26.4 24,100 5.0 25,300 18.9 19,200 4.0 ECM 23,900 17.9 30,400 6.1 26,900 28.5 23,800 5.2 25,500 20.9 19,100 4.2 PSC 28,000 16.3 35,500 5.5 31,000 24.9 28,400 4.7 29,200 18.5 22,200 3.9 ECM 28,000 17.3 35,100 5.8 30,800 26.7 28,000 4.9 29,200 19.4 22,000 4.1 PSC 33,400 17.0 40,400 5.6 35,400 23.2 33,200 4.7 34,300 19.2 25,900 4.1 ECM 33,500 18.1 39,900 5.9 35,400 24.9 32,600 4.9 34,600 20.4 25,600 4.3 PSC 38,500 17.2 46,300 5.6 43,700 25.4 36,200 4.7 40,100 19.4 28,700 3.8 ECM 39,400 19.6 45,100 6.0 44,400 29.5 35,200 5.2 40,700 21.9 27,400 4.1 PSC 47,100 14.8 58,000 4.7 53,600 21.3 47,500 4.0 49,600 16.8 36,600 3.4 ECM 48,900 17.2 57,700 5.2 53,700 23.9 45,700 4.4 50,600 18.8 36,100 3.7 PSC 62,400 15.9 73,900 5.0 68,500 23.1 58,200 4.2 63,900 17.2 46,900 3.7 ECM 63,200 17.2 73,200 5.4 68,900 24.9 58,200 4.6 64,400 18.4 46,400 3.9 PSC 71,000 14.6 82,100 4.6 78,000 21.1 66,100 4.0 72,900 16.2 53,800 3.4 ECM 71,100 15.7 82,000 4.8 78,100 23.0 65,200 4.1 73,000 17.2 53,000 3.6 TSH/V/D 024 TSH/V/D 030 TSH/V/D 036 TSH/V/D 042 TSH/V/D 048 TSH/V/D 060 TSH/V/D 070 Cooling capacities based upon 80.6°F DB, 66.2°F WB entering air temperature Heating capacities based upon 68°F DB, 59°F WB entering air temperature All ratings based upon operation at lower voltage of dual voltage rated models ASHRAE/AHRI/ISO 13256-1. Metric (S-I) Units Water Loop Heat Pump Model Fan Motor Cooling 30°C Capacity kW EER W/W Ground Water Heat Pump Heating 20°C Capacity kW COP Cooling 15°C Capacity kW EER Watts Ground Loop Heat Pump Heating 10°C Capacity kW COP Cooling 25°C Capacity kW EER W/W Heating 0°C Capacity kW COP TSH/V006 PSC 1.85 4.6 2.34 5.4 2.17 7.5 1.85 4.4 1.96 5.4 1.41 3.4 TSH/V009 PSC 2.74 4.5 3.26 4.8 3.26 7.4 2.76 4.3 2.94 5.3 2.09 3.4 TSH/V012 PSC 3.43 4.5 4.05 4.5 3.90 7.2 3.46 4.0 3.60 5.3 2.78 3.5 TSH/V/D 018 PSC 5.47 4.4 6.76 5.2 6.26 7.3 5.45 4.5 5.74 5.4 4.27 3.6 ECM 5.65 4.8 6.85 5.9 6.50 7.7 5.56 4.9 5.94 5.7 4.43 3.9 PSC 6.98 4.9 9.03 5.9 7.77 7.7 7.06 5.0 7.42 5.5 5.63 4.0 ECM 7.00 5.2 8.91 6.1 7.88 8.4 6.98 5.2 7.47 6.1 5.60 4.2 PSC 8.21 4.8 10.40 5.5 9.09 7.3 8.32 4.7 8.56 5.4 6.51 3.9 ECM 8.21 5.1 10.29 5.8 9.03 7.8 8.21 4.9 8.56 5.7 6.45 4.1 PSC 9.79 5.0 11.84 5.6 10.38 6.8 9.73 4.7 10.05 5.6 7.59 4.1 TSH/V/D 024 TSH/V/D 030 TSH/V/D 036 TSH/V/D 042 TSH/V/D 048 TSH/V/D 060 TSH/V/D 070 ECM 9.82 5.3 11.69 5.9 10.38 7.3 9.55 4.9 10.14 6.0 7.50 4.3 PSC 11.28 5.0 13.57 5.6 12.81 7.4 10.61 4.7 11.75 5.7 8.41 3.8 ECM 11.55 5.7 13.22 6.0 13.01 8.6 10.32 5.2 11.93 6.4 8.03 4.1 PSC 13.80 4.3 17.00 4.7 15.71 6.2 13.92 4.0 14.54 4.9 10.73 3.4 ECM 14.33 5.1 16.91 5.2 15.74 7.0 13.39 4.4 14.83 5.5 10.58 3.7 PSC 18.29 4.7 21.66 5.0 20.08 6.8 17.06 4.2 18.73 5.0 13.75 3.7 ECM 18.52 5.0 21.45 5.4 20.19 7.3 17.06 4.6 18.87 5.4 13.60 3.9 PSC 20.81 4.3 24.06 4.6 22.86 6.2 19.37 4.0 21.37 4.8 15.77 3.4 ECM 20.84 4.6 24.03 4.8 22.89 6.7 19.10 4.1 21.40 5.0 15.53 3.6 Cooling capacities based upon 27°C DB, 19°C WB entering air temperature Heating capacities based upon 20°C DB, 15°C WB entering air temperature All ratings based upon operation at lower voltage of dual voltage rated models ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 8 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – Selection Notes For operation in the shaded area when water is used in lieu of an antifreeze solution, the LWT (Leaving Water Temperature) must be calculated. Flow must be maintained to a level such that the LWT is maintained above 40°F [4.4°C] when the JW3 jumper is not clipped (see example below). Otherwise, appropriate levels of a proper antifreeze solution should be used in systems with leaving water temperatures of 40ºF [4.4°C] or below and the JW3 jumper should be clipped. This is due to the potential of the refrigerant temperature being as low as 32°F [0°C] with 40°F [4.4°C] LWT, which may lead to a nuisance cutout due to the activation of the Low Temperature Protection. JW3 should never be clipped for standard range equipment or systems without antifreeze. Example: At 50°F EWT (Entering Water Temperature) and 1.5 gpm/ton, a 3 ton unit has a HE of 22,500 Btuh. To calculate LWT, rearrange the formula for HE as follows: HE = TD x GPM x 500, where HE = Heat of Extraction (Btuh); TD = temperature difference (EWT - LWT) and GPM = U.S. Gallons per Minute. TD = HE / (GPM x 500) Heating - EAT 70°F R EER Airflow CFM HC kW HE LAT COP A A 3 2 4 3 6 5 0 9 0 0 N/A N/A 26.9 27.1 28.1 28.3 28.8 29.0 25.5 25.7 26.8 27.0 27.6 27.8 22.3 22.4 24.1 24.3 25.0 25.2 19.1 19.2 20.9 21 0 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 11.5 11.8 12.8 13.1 13.2 13.6 13.5 13.8 14.7 15.1 15.3 15.7 15.6 16.0 16.8 17.2 17.5 18.0 17.9 18.3 18.9 19.4 19.7 20 3 1.31 1.20 1.34 1.23 1.35 1.23 1.35 1.24 1.38 1.26 1.39 1.27 1.39 1.27 1.41 1.29 1.42 1.30 1.43 1.30 1.44 1.32 1.45 1 33 7.3 7.8 8.5 9.0 8.9 9.4 9.1 9.7 10.2 10.9 10.8 11.4 11.0 11.7 12.1 12.9 12.8 13.5 13.1 13.9 14.1 14.9 14.8 15 7 94 88 96 90 97 91 98 91 100 93 101 94 102 95 105 97 106 98 107 98 109 100 111 101 2.57 2.89 2.80 3.14 2.87 3.23 2.92 3.27 3.14 3.52 3.23 3.63 3.29 3.69 3.49 3.92 3.61 4.05 3.67 4.12 3.84 4.32 3.98 4 47 9 8 2 4 3 7 6 TD = 22,500 / (4.5 x 500) TD = 10°F LWT = EWT - TD LWT = 50 - 10 = 40°F In this example, as long as the EWT does not fall below 50°F, the system will operate as designed. For EWTs below 50°F, higher flow rates will be required (open loop systems, for example, require at least 2 gpm/ton when EWT is below 50°F). ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 9 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TS H/V 006A (PSC Blower) 240 CFM Nominal (Rated) Airflow Cooling, 240 CFM Nominal (Rated) Airflow Heating WPD EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 GPM 2.0 2.0 1.0 1.0 1.5 1.5 2.0 2.0 1.0 1.0 1.5 1.5 2.0 2.0 1.0 1.0 1.5 1.5 2.0 2.0 1.0 1.0 1.5 1.5 2.0 2.0 1.0 1.0 1.5 1.5 2.0 2.0 1.0 1.0 1.5 1.5 2.0 2.0 1.0 1.0 1.5 1.5 2.0 2.0 1.0 1.0 1.5 1.5 2.0 2.0 1.0 1.0 1.5 1.5 2.0 2.0 1.0 1.0 1.5 1.5 2.0 2.0 1.0 1.0 1.5 1.5 2.0 2.0 PSI FT 3.2 3.2 0.3 0.3 1.6 1.6 3.0 3.0 0.3 0.3 1.5 1.5 2.8 2.8 0.3 0.3 1.4 1.4 2.6 2.6 0.2 0.2 1.3 1.3 2.4 2.4 0.2 0.2 1.2 1.2 2.2 2.2 0.2 0.2 1.1 1.1 2.0 2.0 0.2 0.2 1.1 1.1 1.9 1.9 0.2 0.2 1.0 1.0 1.8 1.8 0.1 0.1 0.8 0.8 1.6 1.6 0.1 0.1 0.7 0.7 1.4 1.4 0.1 0.1 0.6 0.6 1.2 1.2 7.4 7.4 0.7 0.7 3.7 3.7 6.9 6.9 0.7 0.7 3.5 3.5 6.5 6.5 0.7 0.7 3.2 3.2 6.0 6.0 0.5 0.5 3.0 3.0 5.5 5.5 0.5 0.5 2.8 2.8 5.1 5.1 0.5 0.5 2.5 2.5 4.6 4.6 0.5 0.5 2.4 2.4 4.4 4.4 0.5 0.5 2.3 2.3 4.2 4.2 0.2 0.2 1.8 1.8 3.7 3.7 0.2 0.2 1.6 1.6 3.2 3.2 0.2 0.2 1.4 1.4 2.8 2.8 Performance capacities shown in thousands of Btuh Cooling - EAT 80/67°F Airflow CFM TC SC Sens/ Tot Ratio kW Heating - EAT 70°F HR EER Operation not recommended 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 6.7 7.0 6.9 7.2 7.0 7.3 7.0 7.3 7.0 7.3 7.1 7.4 6.9 7.2 7.0 7.3 7.1 7.4 6.7 7.0 6.9 7.2 6.9 7.2 6.4 6.6 6.6 6.8 6.7 6.9 5.9 6.2 6.1 6.4 6.3 6.5 5.7 5.9 5.9 6.2 6.0 6.3 5.4 5.6 5.7 5.9 5.8 6.0 4.9 5.1 5.2 5.4 5.3 5.5 4.4 4.6 4.6 4.8 4.8 5.0 3.9 4.1 4.1 4.3 4.2 4.4 3.9 4.7 3.9 4.7 4.0 4.8 4.2 5.0 4.2 5.0 4.2 5.0 4.4 5.2 4.4 5.2 4.4 5.2 4.4 5.3 4.5 5.3 4.5 5.3 4.4 5.2 4.4 5.3 4.4 5.3 4.2 5.0 4.3 5.1 4.3 5.2 4.1 4.9 4.2 5.0 4.2 5.1 4.0 4.8 4.1 4.9 4.2 5.0 3.7 4.5 3.9 4.6 3.9 4.7 3.5 4.1 3.6 4.3 3.7 4.4 3.2 3.8 3.3 3.9 3.4 4.0 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.7 0.8 0.6 0.7 0.6 0.7 0.7 0.8 0.7 0.8 0.7 0.8 0.7 0.8 0.7 0.8 0.7 0.8 0.7 0.8 0.7 0.8 0.7 0.8 0.7 0.8 0.7 0.8 0.7 0.8 0.8 0.9 0.8 0.9 0.7 0.9 0.8 0.9 0.8 0.9 0.8 0.9 0.8 0.9 0.8 0.9 0.8 0.9 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.5 0.4 0.4 0.4 0.4 0.5 0.5 0.4 0.5 0.4 0.4 0.5 0.5 0.5 0.5 0.4 0.5 0.5 0.6 0.5 0.5 0.5 0.5 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.6 0.6 0.6 0.6 7.6 7.9 7.8 8.1 7.9 8.2 7.9 8.2 8.0 8.3 8.0 8.3 8.0 8.3 8.0 8.4 8.1 8.4 7.9 8.2 8.0 8.3 8.0 8.3 7.7 8.0 7.8 8.1 7.9 8.2 7.4 7.7 7.5 7.8 7.6 7.9 7.2 7.5 7.4 7.7 7.5 7.8 7.1 7.3 7.2 7.5 7.3 7.6 6.7 7.0 6.9 7.2 7.0 7.3 6.4 6.7 6.6 6.8 6.6 6.9 6.1 6.4 6.3 6.5 6.3 6.6 25.6 25.8 26.9 27.1 27.7 27.9 24.8 25.0 25.9 26.1 26.7 26.9 22.2 22.4 23.9 24.0 24.7 24.9 19.4 19.6 21.1 21.3 21.9 22.1 16.5 16.6 18.0 18.2 18.9 19.0 13.7 13.8 15.1 15.2 15.8 16.0 12.5 12.6 13.8 13.9 14.5 14.6 11.3 11.4 12.4 12.5 13.1 13.2 9.2 9.3 10.2 10.2 10.7 10.8 7.5 7.6 8.2 8.3 8.6 8.7 6.1 6.1 6.7 6.7 7.0 7.0 Airflow CFM HC kW HE LAT COP 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 180 240 3.8 3.9 4.6 4.7 4.8 4.9 4.9 5.0 5.4 5.6 5.6 5.8 5.7 5.9 6.1 6.3 6.4 6.5 6.5 6.7 6.8 7.0 7.0 7.2 7.2 7.4 7.4 7.6 7.7 7.9 7.9 8.1 8.1 8.4 8.5 8.7 8.7 8.9 8.5 8.7 8.9 9.2 9.2 9.4 8.9 9.1 9.4 9.6 9.7 9.9 0.48 0.44 0.50 0.45 0.50 0.46 0.50 0.46 0.51 0.47 0.51 0.47 0.51 0.47 0.52 0.48 0.52 0.48 0.52 0.48 0.53 0.48 0.53 0.48 0.53 0.48 0.53 0.49 0.53 0.49 0.53 0.49 0.54 0.49 0.54 0.49 0.54 0.49 0.54 0.49 0.54 0.49 0.54 0.50 0.54 0.49 0.54 0.50 0.55 0.50 2.3 2.4 3.0 3.1 3.2 3.3 3.3 3.5 3.7 4.0 3.9 4.2 4.1 4.3 4.4 4.7 4.6 4.9 4.7 5.0 5.0 5.3 5.3 5.6 5.4 5.7 5.6 6.0 5.9 6.3 6.1 6.4 6.3 6.7 6.6 7.0 6.8 7.2 6.7 7.1 7.0 7.5 7.3 7.7 7.0 7.5 7.5 7.9 7.7 8.2 89.6 85.1 93.4 88.0 94.5 88.9 95.0 89.3 97.8 91.4 98.9 92.3 99.5 92.7 101.6 94.3 102.7 95.2 103.3 95.7 105.0 96.9 106.2 97.9 106.9 98.4 108.3 99.5 109.8 100.6 110.6 101.2 111.8 102.2 113.7 103.6 114.7 104.4 113.8 103.8 115.9 105.4 117.2 106.3 115.8 105.3 118.2 107.1 119.6 108.2 2.3 2.6 2.7 3.0 2.8 3.1 2.8 3.2 3.1 3.5 3.2 3.6 3.3 3.7 3.5 3.9 3.6 4.0 3.6 4.1 3.8 4.2 3.9 4.4 4.0 4.5 4.1 4.6 4.2 4.8 4.3 4.9 4.4 5.0 4.6 5.2 4.7 5.3 4.6 5.2 4.8 5.4 5.0 5.6 4.8 5.4 5.1 5.7 5.2 5.8 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 10 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TS H/V 009B (PSC Blower) Performance capacities shown in thousands of Btuh 350 CFM Nominal (Rated) Airflow Cooling, 350 CFM Nominal (Rated) Airflow Heating EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 WPD GPM 2.8 2.8 1.4 1.4 2.1 2.1 2.8 2.8 1.4 1.4 2.1 2.8 2.8 1.4 1.4 2.1 2.1 2.8 2.8 1.4 1.4 2.1 2.1 2.8 2.8 1.4 1.4 2.1 2.1 2.8 2.8 1.4 1.4 2.1 2.1 2.8 2.8 1.4 1.4 2.1 2.1 2.8 2.8 1.4 1.4 2.1 2.1 2.8 2.8 1.4 1.4 2.1 2.1 2.8 2.8 1.4 1.4 2.1 2.1 2.8 2.8 1.4 1.4 2.1 2.1 2.8 2.8 PSI FT 2.8 2.8 0.8 0.8 1.5 1.5 2.7 2.7 0.8 0.8 1.5 2.6 2.6 0.7 0.7 1.4 1.4 2.4 2.4 0.7 0.7 1.3 1.3 2.3 2.3 0.6 0.6 1.2 1.2 2.2 2.2 0.6 0.6 1.1 1.1 2.0 2.0 0.6 0.6 1.1 1.1 1.9 1.9 0.6 0.6 1.1 1.1 1.9 1.9 0.5 0.5 1.0 1.0 1.7 1.7 0.5 0.5 0.9 0.9 1.6 1.6 0.4 0.4 0.8 0.8 1.5 1.5 6.5 6.5 1.8 1.8 3.5 3.5 6.2 6.2 1.7 1.7 3.4 5.9 5.9 1.6 1.6 3.2 3.2 5.6 5.6 1.5 1.5 3.0 3.0 5.3 5.3 1.5 1.5 2.8 2.8 5.0 5.0 1.4 1.4 2.6 2.6 4.7 4.7 1.3 1.3 2.5 2.5 4.5 4.5 1.3 1.3 2.5 2.5 4.3 4.3 1.2 1.2 2.3 2.3 4.0 4.0 1.1 1.1 2.1 2.1 3.7 3.7 1.0 1.0 1.9 1.9 3.4 3.4 Cooling - EAT 80/67°F Airflow CFM TC SC Sens/Tot Ratio kW Heating - EAT°F HR EER Airflow CFM HC kW HE LAT COP 225 300 225 300 225 300 225 300 225 300 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 5.7 5.8 6.6 6.7 6.9 7.0 7.0 7.2 7.7 8.0 8.3 8.3 8.5 8.9 9.1 9.2 9.5 9.4 9.7 9.9 10.2 10.3 10.6 10.5 10.8 10.9 11.2 11.3 11.6 11.6 11.9 11.9 12.2 12.3 12.7 12.6 12.9 12.3 12.7 12.8 13.2 13.1 13.5 12.8 13.2 13.3 13.7 13.6 14.0 0.69 0.63 0.71 0.65 0.72 0.66 0.72 0.66 0.74 0.67 0.68 0.75 0.68 0.76 0.69 0.76 0.70 0.77 0.70 0.77 0.71 0.78 0.71 0.78 0.71 0.79 0.72 0.79 0.72 0.80 0.73 0.80 0.73 0.81 0.74 0.81 0.74 0.81 0.74 0.82 0.75 0.82 0.75 0.82 0.75 0.83 0.76 0.83 0.76 3.5 3.7 4.3 4.6 4.5 4.8 4.7 5.0 5.3 5.7 6.0 5.8 6.2 6.4 6.7 6.7 7.1 6.9 7.3 7.3 7.8 7.7 8.2 7.9 8.4 8.2 8.7 8.6 9.2 8.9 9.4 9.1 9.7 9.6 10.2 9.8 10.4 9.6 10.2 10.0 10.6 10.3 10.9 10.0 10.6 10.5 11.1 10.7 11.4 93.3 88.0 97.0 90.8 98.2 91.7 98.8 92.2 101.9 94.5 95.6 104.0 96.2 106.4 98.0 107.9 99.2 108.8 99.8 110.7 101.4 112.4 102.7 113.3 103.3 114.9 104.5 116.7 105.9 117.6 106.7 118.9 107.6 120.8 109.1 121.9 109.9 120.8 109.1 122.8 110.7 123.9 111.5 122.8 110.6 124.9 112.3 126.0 113.1 2.4 2.7 2.7 3.0 2.8 3.1 2.8 3.2 3.1 3.5 3.6 3.2 3.6 3.4 3.8 3.5 4.0 3.6 4.0 3.8 4.2 3.9 4.4 3.9 4.4 4.1 4.6 4.2 4.7 4.3 4.8 4.3 4.9 4.5 5.0 4.5 5.1 4.5 5.0 4.6 5.2 4.7 5.2 4.6 5.2 4.7 5.3 4.8 5.4 Operation not recommended 225 300 225 300 225 300 225 300 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 225 300 11.6 12.1 11.9 12.4 12.0 12.5 11.3 11.7 12.0 11.6 12.1 10.8 11.3 11.1 11.6 11.2 11.7 10.3 10.7 10.6 11.1 10.8 11.2 9.7 10.1 10.1 10.5 10.3 10.7 9.1 9.5 9.5 9.9 9.7 10.1 8.8 9.1 9.2 9.5 9.3 9.7 8.4 8.8 8.8 9.2 9.0 9.4 7.7 8.0 8.1 8.4 8.3 8.7 6.9 7.2 7.3 7.6 7.5 7.9 6.1 6.4 6.5 6.8 6.7 7.0 6.5 7.8 6.6 7.9 6.7 8.0 6.3 7.6 7.7 6.5 7.8 6.2 7.4 6.3 7.5 6.3 7.6 6.0 7.2 6.1 7.3 6.1 7.4 5.8 6.9 5.9 7.1 6.0 7.1 5.6 6.7 5.7 6.8 5.8 6.9 5.5 6.6 5.6 6.7 5.7 6.8 5.4 6.4 5.5 6.6 5.6 6.7 5.1 6.2 5.3 6.3 5.3 6.4 4.9 5.8 5.0 6.0 5.1 6.1 4.5 5.4 4.7 5.6 4.8 5.7 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.6 0.6 0.6 0.6 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.7 0.8 0.7 0.7 0.6 0.7 0.7 0.8 0.7 0.8 0.7 0.8 0.7 0.9 0.7 0.8 0.7 0.8 0.37 0.38 0.34 0.35 0.32 0.33 0.42 0.44 0.40 0.37 0.39 0.48 0.49 0.44 0.46 0.42 0.44 0.53 0.55 0.50 0.51 0.48 0.5 0.59 0.61 0.56 0.58 0.54 0.56 0.66 0.68 0.62 0.64 0.60 0.62 0.69 0.71 0.65 0.67 0.63 0.65 0.72 0.75 0.69 0.71 0.67 0.69 0.79 0.82 0.75 0.78 0.74 0.76 0.86 0.89 0.83 0.85 0.81 0.84 0.94 0.97 0.90 0.93 0.88 0.91 12.9 13.4 13.0 13.5 13.1 13.6 12.7 13.2 13.3 12.9 13.4 12.4 12.9 12.6 13.1 12.7 13.2 12.1 12.6 12.3 12.8 12.4 12.9 11.8 12.2 12.0 12.5 12.1 12.6 11.4 11.8 11.6 12.1 11.7 12.2 11.1 11.6 11.4 11.8 11.5 12.0 10.9 11.3 11.2 11.6 11.3 11.7 10.4 10.8 10.7 11.1 10.8 11.2 9.9 10.3 10.2 10.6 10.3 10.7 9.3 9.7 9.6 10.0 9.7 10.1 31.4 31.6 34.9 35.2 36.9 37.2 26.7 26.9 29.8 31.2 31.5 22.7 22.9 25.1 25.3 26.5 26.7 19.3 19.5 21.3 21.5 22.5 22.6 16.4 16.5 18.1 18.2 19.0 19.2 13.9 14.0 15.3 15.4 16.1 16.2 12.8 12.9 14.1 14.2 14.8 14.9 11.7 11.8 12.9 13 13.5 13.6 9.7 9.8 10.8 10.8 11.3 11.4 8 8.1 8.9 8.9 9.3 9.4 6.5 6.6 7.2 7.3 7.6 7.7 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 11 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TS H/V 012A (PSC Blower) 350 CFM Nominal (Rated) Airflow Cooling, 350 CFM Nominal (Rated) Airflow Heating WPD EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 GPM 3.5 3.5 1.8 1.8 2.6 2.6 3.5 3.5 1.8 1.8 2.6 2.6 3.5 3.5 1.8 1.8 2.6 2.6 3.5 3.5 1.8 1.8 2.6 2.6 3.5 3.5 1.8 1.8 2.6 2.6 3.5 3.5 1.8 1.8 2.6 2.6 3.5 3.5 1.8 1.8 2.6 2.6 3.5 3.5 1.8 1.8 2.6 2.6 3.5 3.5 1.8 1.8 2.6 2.6 3.5 3.5 1.8 1.8 2.6 2.6 3.5 3.5 1.8 1.8 2.6 2.6 3.5 3.5 PSI FT 4.0 4.0 0.6 0.6 2.1 2.1 3.8 3.8 0.6 0.6 2.0 2.0 3.6 3.6 0.5 0.5 1.9 1.9 3.4 3.4 0.4 0.4 1.8 1.8 3.2 3.2 0.4 0.4 1.6 1.6 3.0 3.0 0.3 0.3 1.5 1.5 2.8 2.8 0.3 0.3 1.5 1.5 2.7 2.7 0.3 0.3 1.4 1.4 2.6 2.6 0.2 0.2 1.3 1.3 2.4 2.4 0.1 0.1 1.2 1.2 2.2 2.2 0.1 0.1 1.1 1.1 2.0 2.0 9.2 9.2 1.4 1.4 4.8 4.8 8.8 8.8 1.3 1.3 4.6 4.6 8.3 8.3 1.1 1.1 4.3 4.3 7.9 7.9 1.0 1.0 4.1 4.1 7.4 7.4 0.9 0.9 3.8 3.8 6.9 6.9 0.7 0.7 3.5 3.5 6.5 6.5 0.7 0.7 3.4 3.4 6.3 6.3 0.6 0.6 3.3 3.3 6.0 6.0 0.5 0.5 3.0 3.0 5.6 5.6 0.3 0.3 2.7 2.7 5.1 5.1 0.2 0.2 2.5 2.5 4.6 4.6 Airflow CFM TC Cooling - EAT 80/67°F Sens/ SC Tot kW Ratio Performance capacities shown in thousands of Btuh Heating - EAT 70°F HR EER Operation not recommended 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 12.1 12.6 12.3 12.8 12.7 13.3 12.7 13.2 12.8 13.3 12.9 13.5 12.7 13.2 12.9 13.4 12.9 13.5 12.5 13.0 12.7 13.3 12.8 13.4 12.0 12.5 12.3 12.8 12.5 13.0 11.3 11.7 11.7 12.2 11.9 12.4 10.9 11.3 11.3 11.8 11.5 12.0 10.4 10.9 10.9 11.4 11.1 11.6 9.5 9.9 10.0 10.4 10.2 10.7 8.5 8.9 9.0 9.4 9.3 9.6 7.5 7.8 8.0 8.3 8.2 8.6 6.5 7.8 6.6 7.9 6.8 8.1 6.9 8.2 6.9 8.3 6.9 8.3 6.9 8.3 7.0 8.3 7.0 8.4 6.9 8.2 6.9 8.3 7.0 8.4 6.7 8.0 6.8 8.1 6.9 8.2 6.5 7.8 6.6 7.9 6.7 8.0 6.4 7.6 6.5 7.8 6.5 7.8 6.2 7.5 6.4 7.6 6.4 7.7 6.0 7.2 6.1 7.3 6.2 7.4 5.7 6.9 5.9 7.0 5.9 7.1 5.5 6.6 5.6 6.7 5.7 6.8 0.5 0.6 0.5 0.6 0.5 0.6 0.5 0.6 0.5 0.6 0.5 0.6 0.5 0.6 0.5 0.6 0.5 0.6 0.5 0.6 0.5 0.6 0.5 0.6 0.6 0.6 0.6 0.6 0.5 0.6 0.6 0.7 0.6 0.6 0.6 0.6 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.6 0.7 0.7 0.8 0.7 0.7 0.6 0.7 0.7 0.8 0.7 0.8 0.7 0.8 0.50 0.51 0.48 0.49 0.47 0.48 0.55 0.56 0.52 0.53 0.50 0.52 0.61 0.63 0.57 0.59 0.55 0.57 0.67 0.69 0.63 0.65 0.61 0.63 0.75 0.77 0.70 0.73 0.68 0.70 0.83 0.85 0.78 0.81 0.76 0.78 0.87 0.90 0.82 0.85 0.80 0.83 0.91 0.94 0.87 0.89 0.84 0.87 1.00 1.04 0.96 0.99 0.93 0.96 1.10 1.14 1.05 1.09 1.03 1.06 1.20 1.24 1.15 1.19 1.13 1.16 13.8 14.4 13.9 14.5 14.3 14.9 14.6 15.2 14.6 15.2 14.6 15.2 14.8 15.4 14.8 15.4 14.8 15.4 14.8 15.4 14.9 15.5 14.9 15.5 14.5 15.1 14.7 15.3 14.8 15.4 14.1 14.7 14.3 14.9 14.5 15.0 13.8 14.4 14.1 14.7 14.2 14.8 13.5 14.1 13.9 14.4 14.0 14.6 12.9 13.4 13.3 13.8 13.4 14.0 12.3 12.8 12.6 13.1 12.8 13.3 11.6 12.0 11.9 12.4 12.1 12.5 24.4 24.6 25.9 26.1 27.3 27.5 23.3 23.5 24.8 25.0 25.6 25.8 21.0 21.2 22.6 22.7 23.4 23.5 18.6 18.8 20.2 20.3 20.9 21.1 16.1 16.2 17.5 17.7 18.3 18.4 13.6 13.7 15.0 15.1 15.7 15.8 12.5 12.6 13.8 13.9 14.5 14.6 11.4 11.5 12.6 12.7 13.2 13.3 9.5 9.5 10.5 10.5 11.0 11.1 7.7 7.8 8.6 8.6 9.0 9.1 6.2 6.3 6.9 7.0 7.3 7.3 Airflow CFM HC kW HE LAT COP 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 265 350 7.7 8.0 8.9 9.1 9.3 9.5 9.5 9.7 10.3 10.6 10.7 11.0 10.9 11.2 11.5 11.8 11.9 12.2 12.0 12.4 12.5 12.8 12.8 13.1 12.9 13.3 13.2 13.5 13.4 13.8 13.5 13.9 13.7 14.0 13.8 14.2 13.8 14.2 13.8 14.1 13.8 14.2 13.9 14.2 13.9 14.3 13.9 14.3 13.9 14.3 0.89 0.82 0.92 0.85 0.94 0.86 0.94 0.86 0.97 0.88 0.98 0.89 0.98 0.90 1.00 0.92 1.01 0.93 1.02 0.93 1.03 0.94 1.04 0.95 1.05 0.96 1.06 0.97 1.06 0.97 1.07 0.98 1.07 0.98 1.08 0.98 1.08 0.98 1.08 0.98 1.08 0.98 1.08 0.98 1.08 0.99 1.08 0.98 1.07 0.98 4.9 5.2 5.9 6.3 6.2 6.6 6.4 6.8 7.2 7.6 7.5 8.0 7.7 8.1 8.2 8.7 8.5 9.0 8.7 9.2 9.0 9.6 9.3 9.9 9.4 10.0 9.7 10.3 9.9 10.5 9.9 10.6 10.1 10.7 10.2 10.8 10.2 10.9 10.2 10.8 10.2 10.9 10.3 10.9 10.3 10.9 10.3 10.9 10.3 10.9 97.1 91.0 101.0 94.1 102.4 95.1 103.1 95.7 106.0 98.0 107.4 99.1 108.1 99.6 110.2 101.2 111.5 102.2 112.1 102.7 113.6 103.9 114.6 104.7 115.1 105.1 116.1 105.8 116.9 106.4 117.2 106.7 117.8 107.1 118.2 107.4 118.3 107.6 118.1 107.4 118.4 107.6 118.5 107.7 118.5 107.7 118.6 107.7 118.6 107.8 2.5 2.8 2.8 3.2 2.9 3.3 2.9 3.3 3.1 3.5 3.2 3.6 3.2 3.6 3.4 3.8 3.4 3.9 3.5 3.9 3.5 4.0 3.6 4.0 3.6 4.1 3.7 4.1 3.7 4.1 3.7 4.2 3.7 4.2 3.8 4.2 3.8 4.2 3.8 4.2 3.8 4.2 3.8 4.2 3.8 4.2 3.8 4.3 3.8 4.3 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 12 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TS H/V/D 018B (PSC Blower) Performance capacities shown in thousands of Btuh 600 CFM Nominal (Rated) Airflow Cooling, 600 CFM Nominal (Rated) Airflow Heating WPD EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 GPM 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 PSI FT 3.9 3.9 0.7 0.7 2.1 2.1 3.5 3.5 0.6 0.6 2.0 2.0 3.2 3.2 0.5 0.5 1.7 1.7 2.8 2.8 0.3 0.3 1.5 1.5 2.6 2.6 0.3 0.3 1.4 1.4 2.4 2.4 0.2 0.2 1.2 1.2 2.2 2.2 0.2 0.2 1.2 1.2 2.1 2.1 0.2 0.2 1.1 1.1 2.0 2.0 0.2 0.2 1.1 1.1 1.9 1.9 0.1 0.1 0.9 0.9 1.7 1.7 0.1 0.1 0.8 0.8 1.6 1.6 9.0 9.0 1.6 1.6 4.9 4.9 8.1 8.1 1.4 1.4 4.6 4.6 7.4 7.4 1.2 1.2 3.9 3.9 6.5 6.5 0.7 0.7 3.5 3.5 6.0 6.0 0.7 0.7 3.2 3.2 5.5 5.5 0.5 0.5 2.8 2.8 5.1 5.1 0.5 0.5 2.7 2.7 4.9 4.9 0.5 0.5 2.5 2.5 4.6 4.6 0.5 0.5 2.5 2.5 4.4 4.4 0.2 0.2 2.1 2.1 3.9 3.9 0.2 0.2 1.8 1.8 3.7 3.7 Airflow CFM TC Cooling - EAT 80/67°F Sens/ SC Tot kW HR Ratio Heating - EAT 70°F EER HWC Operation not recommended 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 20.7 21.5 21.0 21.8 21.2 22.0 20.8 21.7 21.0 21.8 21.2 22.1 20.6 21.5 21.0 21.8 21.1 21.9 19.9 20.7 20.4 21.2 20.6 21.4 18.9 19.7 19.5 20.3 19.8 20.6 17.7 18.5 18.4 19.2 18.7 19.5 17.1 17.8 17.8 18.5 18.1 18.9 16.5 17.2 17.2 17.9 17.5 18.3 15.2 15.9 15.9 16.6 16.3 16.9 14.0 14.6 14.6 15.2 15.0 15.6 12.9 13.4 13.4 14.0 13.7 14.3 16.8 14.0 16.8 14.1 16.8 14.1 17.2 14.4 17.2 14.4 17.3 14.5 17.3 14.5 17.5 14.6 17.5 14.6 16.8 14.1 17.2 14.3 17.3 14.4 16.2 13.5 16.6 13.8 16.8 14.0 15.4 12.9 15.9 13.2 16.1 13.4 15.0 12.6 15.5 12.9 15.7 13.1 14.7 12.3 15.1 12.6 15.3 12.8 14.0 11.7 14.3 12.0 14.5 12.1 13.4 11.2 13.7 11.4 13.8 11.6 13.1 10.9 13.2 11.0 13.3 11.1 0.81 0.65 0.80 0.64 0.80 0.64 0.83 0.66 0.82 0.66 0.82 0.66 0.84 0.67 0.83 0.67 0.83 0.67 0.85 0.68 0.84 0.68 0.84 0.67 0.86 0.69 0.85 0.68 0.85 0.68 0.87 0.70 0.86 0.69 0.86 0.69 0.88 0.70 0.87 0.70 0.86 0.69 0.89 0.71 0.88 0.70 0.87 0.70 0.92 0.74 0.90 0.72 0.89 0.72 0.96 0.77 0.94 0.75 0.93 0.74 1.02 0.82 0.99 0.79 0.97 0.78 0.78 0.80 0.74 0.76 0.72 0.75 0.85 0.88 0.81 0.83 0.79 0.81 0.95 0.98 0.89 0.92 0.86 0.89 1.05 1.09 0.99 1.02 0.96 0.99 1.17 1.21 1.10 1.14 1.07 1.10 1.31 1.35 1.23 1.27 1.19 1.23 1.39 1.43 1.30 1.35 1.26 1.30 1.46 1.51 1.38 1.42 1.33 1.38 1.64 1.69 1.54 1.59 1.50 1.55 1.84 1.90 1.73 1.79 1.68 1.74 2.06 2.13 1.94 2.01 1.89 1.95 23.3 24.3 23.5 24.4 23.6 24.6 23.7 24.6 23.7 24.7 23.9 24.8 23.9 24.8 24.0 25.0 24.0 25.0 23.5 24.4 23.7 24.7 23.8 24.8 22.9 23.8 23.2 24.2 23.4 24.3 22.2 23.1 22.6 23.5 22.8 23.7 21.9 22.7 22.2 23.1 22.4 23.3 21.5 22.4 21.9 22.8 22.1 23.0 20.8 21.7 21.2 22.0 21.4 22.2 20.3 21.1 20.5 21.4 20.7 21.5 19.9 20.7 20.1 20.8 20.2 21.0 26.6 26.8 28.4 28.6 29.3 29.6 24.5 24.7 26.0 26.2 26.9 27.1 21.8 22.0 23.5 23.7 24.4 24.6 18.9 19.1 20.6 20.8 21.5 21.7 16.1 16.2 17.7 17.9 18.6 18.7 13.6 13.7 15.0 15.1 15.7 15.9 12.4 12.5 13.7 13.8 14.4 14.6 11.3 11.4 12.5 12.6 13.1 13.2 9.3 9.4 10.3 10.4 10.9 10.9 7.6 7.7 8.4 8.5 8.9 9.0 6.2 6.3 6.9 7.0 7.3 7.3 0.6 0.6 0.5 0.6 0.5 0.5 0.9 1.0 0.9 0.9 0.8 0.8 1.5 1.5 1.3 1.4 1.2 1.3 2.0 2.1 1.8 1.9 1.6 1.7 2.7 2.8 2.4 2.5 2.1 2.2 3.2 3.3 3.0 3.1 2.7 2.9 3.6 3.7 3.3 3.5 3.1 3.2 4.1 4.3 3.8 3.9 3.5 3.6 4.5 4.6 4.3 4.4 4.2 4.3 5.3 5.4 5.2 5.3 5.0 5.1 6.3 6.4 6.1 6.2 5.9 6.0 Airflow CFM HC kW HE LAT COP HWC 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 12.2 12.5 13.7 14.0 14.2 14.6 14.5 14.9 15.8 16.3 16.5 16.9 16.8 17.3 18.0 18.5 18.7 19.2 19.2 19.7 20.1 20.7 21.0 21.6 21.5 22.1 22.3 22.9 23.4 24.0 23.9 24.6 24.6 25.2 25.8 26.5 26.5 27.2 25.8 26.4 27.1 27.8 27.8 28.6 26.9 27.7 28.4 29.1 29.1 29.9 1.36 1.24 1.40 1.28 1.41 1.29 1.42 1.30 1.44 1.32 1.45 1.33 1.46 1.33 1.47 1.35 1.48 1.35 1.49 1.36 1.50 1.37 1.51 1.38 1.52 1.39 1.54 1.40 1.56 1.43 1.57 1.44 1.59 1.46 1.63 1.49 1.66 1.52 1.63 1.49 1.69 1.54 1.72 1.58 1.68 1.53 1.74 1.60 1.79 1.63 7.8 8.3 9.2 9.7 9.6 10.2 9.9 10.5 11.1 11.8 11.7 12.4 12.0 12.8 13.1 13.9 13.8 14.6 14.2 15.1 15.1 16.0 15.9 16.9 16.4 17.4 17.1 18.1 18.0 19.1 18.5 19.7 19.1 20.3 20.2 21.4 20.7 22.0 20.1 21.3 21.2 22.5 21.8 23.2 21.1 22.4 22.3 23.6 22.9 24.3 95.0 89.3 98.1 91.7 99.3 92.5 99.9 93.0 102.6 95.1 103.9 96.1 104.7 96.7 107.0 98.5 108.6 99.7 109.4 100.4 111.4 101.9 113.3 103.3 114.3 104.1 115.9 105.4 118.1 107.0 119.3 107.9 120.6 108.9 123.1 110.9 124.5 111.9 123.0 110.8 125.7 112.9 127.2 114.1 125.4 112.7 128.3 114.9 130.0 116.2 2.6 2.9 2.9 3.2 2.9 3.3 3.0 3.4 3.2 3.6 3.3 3.7 3.4 3.8 3.6 4.0 3.7 4.2 3.8 4.2 3.9 4.4 4.1 4.6 4.1 4.7 4.3 4.8 4.4 4.9 4.5 5.0 4.5 5.1 4.6 5.2 4.7 5.3 4.6 5.2 4.7 5.3 4.7 5.3 4.7 5.3 4.8 5.3 4.8 5.4 1.4 1.5 1.7 1.7 1.8 1.8 1.8 1.9 1.9 2.0 2.0 2.1 2.1 2.1 2.2 2.3 2.3 2.4 2.4 2.4 2.5 2.6 2.6 2.6 2.7 2.7 2.8 2.8 2.9 2.9 3.0 3.1 3.0 3.1 3.1 3.2 3.2 3.3 3.1 3.2 3.3 3.3 3.4 3.5 3.3 3.4 3.4 3.5 3.5 3.6 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 13 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TS H/V/D 018B (ECM Blower) 750 CFM Nominal (Rated) Airflow Cooling, 750 CFM Nominal (Rated) Airflow Heating EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 WPD GPM 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 2.8 2.8 4.1 4.1 5.5 5.5 PSI FT 3.9 3.9 0.7 0.7 2.1 2.1 3.5 3.5 0.6 0.6 2 2 3.2 3.2 0.5 0.5 1.7 1.7 2.8 2.8 0.3 0.3 1.5 1.5 2.6 2.6 0.3 0.3 1.4 1.4 2.4 2.4 0.2 0.2 1.2 1.2 2.2 2.2 0.2 0.2 1.15 1.15 2.1 2.1 0.2 0.2 1.1 1.1 2 2 0.2 0.2 1.1 1.1 1.9 1.9 0.1 0.1 0.9 0.9 1.7 1.7 0.1 0.1 0.8 0.8 1.6 1.6 9.0 9.0 1.6 1.6 4.9 4.9 8.1 8.1 1.4 1.4 4.6 4.6 7.4 7.4 1.2 1.2 3.9 3.9 6.5 6.5 0.7 0.7 3.5 3.5 6.0 6.0 0.7 0.7 3.2 3.2 5.5 5.5 0.5 0.5 2.8 2.8 5.1 5.1 0.5 0.5 2.7 2.7 4.9 4.9 0.5 0.5 2.5 2.5 4.6 4.6 0.5 0.5 2.5 2.5 4.4 4.4 0.2 0.2 2.1 2.1 3.9 3.9 0.2 0.2 1.8 1.8 3.7 3.7 Performance capacities shown in thousands of Btuh Cooling - EAT 80/67°F Airflow CFM TC SC Sens/ Tot Ratio kW HR Heating - EAT 70°F EER HWC Operation not recommended 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 20.3 21.1 20.7 21.5 21.3 22.1 20.8 21.6 21.3 22.1 21.5 22.4 21.3 22.1 21.5 22.3 21.6 22.5 20.6 21.5 21.1 22.0 21.3 22.2 19.6 20.4 20.3 21.1 20.6 21.4 18.4 19.2 19.1 19.9 19.5 20.3 17.8 18.5 18.5 19.2 18.9 19.6 17.2 17.8 17.9 18.6 18.2 19.0 15.9 16.5 16.6 17.2 16.9 17.6 14.7 15.3 15.3 15.9 15.6 16.3 13.8 14.4 14.3 14.8 14.5 15.1 12.4 14.5 12.6 14.7 12.9 15.0 12.9 15.0 13.1 15.2 13.2 15.3 13.5 15.7 13.5 15.7 13.5 15.7 13.6 15.8 13.6 15.9 13.6 15.9 13.4 15.6 13.5 15.7 13.6 15.8 13.1 15.2 13.3 15.4 13.4 15.5 12.9 15.0 13.1 15.2 13.2 15.3 12.7 14.8 12.9 15.0 13.0 15.2 12.3 14.3 12.5 14.6 12.6 14.7 12.0 13.9 12.1 14.1 12.2 14.2 11.5 13.4 11.8 13.7 11.9 13.9 0.61 0.68 0.61 0.68 0.61 0.68 0.62 0.70 0.61 0.69 0.61 0.69 0.63 0.71 0.63 0.70 0.62 0.70 0.66 0.74 0.65 0.72 0.64 0.72 0.68 0.76 0.67 0.75 0.66 0.74 0.71 0.79 0.69 0.78 0.69 0.77 0.72 0.81 0.71 0.79 0.70 0.78 0.74 0.83 0.72 0.81 0.71 0.80 0.77 0.87 0.76 0.85 0.75 0.84 0.81 0.91 0.79 0.89 0.78 0.88 0.83 0.93 0.83 0.92 0.82 0.92 0.75 0.79 0.71 0.75 0.70 0.74 0.81 0.86 0.77 0.81 0.75 0.79 0.90 0.95 0.84 0.89 0.82 0.87 0.99 1.05 0.93 0.99 0.90 0.96 1.11 1.17 1.04 1.10 1.00 1.06 1.24 1.31 1.16 1.23 1.12 1.19 1.32 1.40 1.24 1.31 1.20 1.26 1.40 1.48 1.31 1.38 1.27 1.34 1.58 1.67 1.48 1.56 1.43 1.51 1.79 1.89 1.67 1.77 1.62 1.71 2.03 2.14 1.90 2.01 1.83 1.94 22.8 23.8 23.1 24.1 23.6 24.6 23.5 24.5 23.9 24.9 24.0 25.1 24.3 25.3 24.3 25.4 24.4 25.4 24.0 25.0 24.3 25.3 24.4 25.4 23.4 24.4 23.8 24.8 24.0 25.0 22.7 23.6 23.1 24.1 23.3 24.3 22.3 23.3 22.7 23.7 22.9 23.9 21.9 22.9 22.3 23.3 22.6 23.5 21.3 22.2 21.6 22.6 21.8 22.8 20.9 21.8 21.1 22.0 21.2 22.1 20.8 21.7 20.8 21.7 20.8 21.7 27.3 26.8 29.1 28.6 30.5 30.0 25.5 25.1 27.6 27.2 28.6 28.1 23.7 23.3 25.5 25.1 26.4 26.0 20.8 20.4 22.7 22.3 23.6 23.2 17.7 17.4 19.5 19.2 20.5 20.1 14.8 14.6 16.5 16.2 17.3 17.0 13.5 13.3 15.1 14.8 15.9 15.6 12.3 12.1 13.7 13.4 14.4 14.2 10.1 9.9 11.2 11.0 11.8 11.6 8.3 8.1 9.2 9.0 9.7 9.5 6.8 6.7 7.5 7.4 7.9 7.8 0.6 0.6 0.5 0.6 0.5 0.5 0.9 1.0 0.9 0.9 0.8 0.8 1.5 1.5 1.3 1.4 1.2 1.3 2.0 2.1 1.8 1.9 1.6 1.7 2.7 2.8 2.4 2.5 2.1 2.2 3.2 3.3 3.0 3.1 2.7 2.9 3.6 3.7 3.3 3.5 3.1 3.2 4.1 4.3 3.8 3.9 3.5 3.6 4.5 4.6 4.3 4.4 4.2 4.3 5.3 5.4 5.2 5.3 5.0 5.1 6.3 6.4 6.1 6.2 5.9 6.0 Airflow CFM HC kW HE LAT COP HWC 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 550 750 11.9 12.3 13.2 13.6 13.7 14.1 14.0 14.4 15.3 15.8 16.0 16.5 16.3 16.8 17.5 18.1 18.4 18.9 18.8 19.4 19.8 20.4 20.8 21.4 21.3 22.0 22.1 22.8 23.2 23.9 23.8 24.5 24.3 25.1 25.5 26.3 26.0 26.8 25.4 26.2 26.5 27.3 27.0 27.9 26.4 27.2 27.5 28.4 28.0 28.9 1.25 1.16 1.29 1.20 1.31 1.21 1.31 1.21 1.33 1.23 1.34 1.24 1.34 1.24 1.35 1.25 1.36 1.26 1.36 1.26 1.37 1.27 1.38 1.28 1.39 1.28 1.40 1.29 1.42 1.31 1.43 1.32 1.45 1.34 1.49 1.38 1.52 1.40 1.49 1.38 1.55 1.43 1.59 1.47 1.54 1.42 1.61 1.49 1.66 1.53 7.9 8.4 9.0 9.6 9.5 10.1 9.7 10.3 10.9 11.6 11.5 12.3 11.9 12.6 13.0 13.8 13.8 14.6 14.2 15.1 15.2 16.1 16.1 17.1 16.6 17.6 17.3 18.4 18.3 19.4 18.8 20.0 19.3 20.5 20.3 21.5 20.7 22.0 20.2 21.4 21.1 22.4 21.5 22.8 21.0 22.4 21.9 23.2 22.3 23.6 90.0 85.1 92.3 86.8 93.1 87.5 93.6 87.8 95.8 89.5 96.9 90.3 97.5 90.8 99.5 92.3 100.9 93.4 101.7 93.9 103.4 95.2 105.0 96.5 105.9 97.1 107.2 98.2 109.0 99.5 110.0 100.2 111.0 101.0 112.9 102.4 113.8 103.1 112.7 102.3 114.6 103.7 115.5 104.4 114.5 103.6 116.3 105.0 117.2 105.7 2.8 3.1 3.0 3.3 3.1 3.4 3.1 3.5 3.4 3.8 3.5 3.9 3.6 4.0 3.8 4.2 4.0 4.4 4.0 4.5 4.2 4.7 4.4 4.9 4.5 5.0 4.6 5.2 4.8 5.3 4.9 5.4 4.9 5.5 5.0 5.6 5.0 5.6 5.0 5.6 5.0 5.6 5.0 5.6 5.0 5.6 5.0 5.6 5.0 5.5 1.4 1.5 1.7 1.7 1.8 1.8 1.8 1.9 1.9 2.0 2.0 2.1 2.1 2.1 2.2 2.3 2.3 2.4 2.4 2.4 2.5 2.6 2.6 2.6 2.7 2.7 2.8 2.8 2.9 2.9 3.0 3.1 3.0 3.1 3.1 3.2 3.2 3.3 3.1 3.2 3.3 3.3 3.4 3.5 3.3 3.4 3.4 3.5 3.5 3.6 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 14 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TS H/V/D 024 (PSC Blower) 950 CFM Nominal (Rated) Airflow Cooling, 950 CFM Nominal (Rated) Airflow Heating WPD EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 GPM 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 PSI FT 1.9 1.9 0.9 0.9 1.2 1.2 1.7 1.7 0.7 0.7 1.0 1.0 1.6 1.6 0.5 0.5 0.9 0.9 1.5 1.5 0.4 0.4 0.8 0.8 1.4 1.4 0.3 0.3 0.7 0.7 1.3 1.3 0.2 0.2 0.7 0.7 1.2 1.2 0.2 0.2 0.6 0.6 1.1 1.1 0.1 0.1 0.6 0.6 1.1 1.1 0.1 0.1 0.5 0.5 1.0 1.0 0.0 0.0 0.5 0.5 0.8 0.8 0.0 0.0 0.3 0.3 0.6 0.6 4.4 4.4 2.1 2.1 2.7 2.7 4.0 4.0 1.5 1.5 2.4 2.4 3.6 3.6 1.2 1.2 2.1 2.1 3.3 3.3 0.9 0.9 1.8 1.8 3.1 3.1 0.6 0.6 1.7 1.7 2.9 2.9 0.5 0.5 1.5 1.5 2.7 2.7 0.4 0.4 1.5 1.5 2.6 2.6 0.3 0.3 1.4 1.4 2.5 2.5 0.2 0.2 1.2 1.2 2.2 2.2 0.1 0.1 1.0 1.0 1.9 1.9 0.0 0.0 0.8 0.8 1.5 1.5 Airflow CFM TC Cooling - EAT 80/67°F Sens/ SC Tot kW HR Ratio Performance capacities shown in thousands of Btuh Heating - EAT 70°F EER HWC Operation not recommended 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 28.1 30.4 27.5 29.7 26.9 29.1 28.1 30.4 28.2 30.5 28.1 30.4 27.4 29.6 28.0 30.3 28.2 30.5 26.2 28.3 27.1 29.3 27.5 29.8 24.6 26.6 25.7 27.8 26.3 28.4 22.8 24.7 24.0 26.0 24.7 26.7 21.9 23.7 23.1 25.0 23.7 25.7 21.0 22.7 22.2 24.0 22.8 24.7 19.1 20.7 20.3 21.9 20.9 22.6 17.5 18.9 18.5 20.0 19.0 20.5 16.2 17.5 16.9 18.3 17.3 18.7 16.5 19.4 15.6 18.3 14.9 17.6 17.1 20.2 16.7 19.7 16.4 19.3 17.2 20.2 17.2 20.2 17.1 20.1 16.8 19.7 17.1 20.1 17.2 20.2 16.1 19.0 16.6 19.5 16.8 19.8 15.3 18.1 15.9 18.7 16.2 19.0 14.9 17.6 15.5 18.2 15.8 18.5 14.5 17.1 15.1 17.7 15.4 18.1 13.8 16.2 14.2 16.7 14.5 17.1 13.2 15.5 13.5 15.9 13.7 16.1 12.9 15.1 13.0 15.3 13.1 15.4 0.59 0.64 0.57 0.62 0.56 0.60 0.61 0.66 0.59 0.65 0.58 0.64 0.63 0.68 0.61 0.67 0.61 0.66 0.64 0.70 0.63 0.69 0.62 0.68 0.66 0.71 0.65 0.70 0.64 0.70 0.67 0.73 0.66 0.72 0.66 0.71 0.68 0.74 0.67 0.73 0.66 0.72 0.69 0.75 0.68 0.74 0.67 0.73 0.72 0.78 0.70 0.76 0.69 0.76 0.75 0.82 0.73 0.80 0.72 0.78 0.79 0.86 0.77 0.84 0.76 0.82 0.89 0.94 0.83 0.87 0.80 0.84 1.00 1.05 0.92 0.97 0.88 0.93 1.10 1.16 1.02 1.07 0.98 1.03 1.23 1.29 1.13 1.19 1.09 1.15 1.36 1.43 1.26 1.33 1.22 1.28 1.51 1.59 1.41 1.48 1.36 1.43 1.6 1.68 1.49 1.57 1.44 1.51 1.68 1.77 1.57 1.65 1.51 1.59 1.88 1.98 1.76 1.85 1.69 1.78 2.10 2.21 1.97 2.07 1.90 2.00 2.36 2.48 2.21 2.32 2.13 2.24 32.0 33.6 31.0 32.7 30.3 31.9 32.3 34.0 32.1 33.8 31.9 33.5 31.9 33.6 32.3 34.0 32.3 34.0 31.0 32.7 31.7 33.4 32.0 33.7 29.9 31.5 30.7 32.4 31.1 32.8 28.6 30.1 29.5 31.0 30.0 31.5 27.9 29.4 28.8 30.3 29.3 30.8 27.3 28.7 28.1 29.6 28.6 30.1 26.1 27.4 26.8 28.2 27.2 28.6 25.1 26.5 25.7 27.0 26.0 27.3 24.7 26.0 24.9 26.2 25.1 26.4 31.5 32.4 33.2 34.1 33.7 34.6 28.2 29.0 30.6 31.5 31.7 32.6 24.8 25.5 27.5 28.3 28.8 29.6 21.3 21.9 24.0 24.6 25.2 25.9 18.1 18.6 20.4 20.9 21.6 22.2 15.1 15.5 17.1 17.6 18.1 18.6 13.8 14.2 15.6 16.0 16.6 17.1 12.4 12.8 14.1 14.5 15.1 15.5 10.2 10.5 11.5 11.8 12.3 12.7 8.3 8.6 9.4 9.6 10.0 10.3 6.9 7.1 7.7 7.9 8.1 8.4 0.8 0.8 0.7 0.7 0.6 0.6 1.0 1.1 0.9 0.9 0.8 0.8 1.4 1.5 1.1 1.2 1.0 1.1 1.8 1.9 1.5 1.6 1.3 1.4 2.3 2.4 1.9 2.0 1.8 1.9 2.9 3.0 2.5 2.6 2.3 2.4 3.2 3.4 2.8 2.9 2.6 2.7 3.5 3.7 3.0 3.2 2.9 3.0 4.2 4.4 3.7 3.9 3.5 3.7 5.0 5.3 4.6 4.8 4.3 4.5 6.0 6.3 5.4 5.7 5.1 5.4 Airflow CFM HC kW HE LAT COP HWC 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 15.7 16.4 17.4 18.2 18.3 19.1 18.8 19.6 20.2 21.1 21.2 22.2 21.8 22.8 22.9 24.0 24.2 25.3 24.9 26.0 25.7 26.9 27.2 28.4 28.0 29.2 28.6 29.8 30.2 31.6 31.2 32.6 31.4 32.9 33.4 34.9 34.5 36.0 32.9 34.4 35.0 36.6 36.2 37.8 34.4 36.0 36.6 38.3 37.9 39.6 1.69 1.50 1.69 1.50 1.70 1.51 1.70 1.51 1.71 1.52 1.71 1.52 1.71 1.52 1.72 1.53 1.73 1.54 1.73 1.54 1.74 1.55 1.75 1.56 1.75 1.56 1.76 1.57 1.79 1.59 1.80 1.60 1.80 1.60 1.83 1.63 1.85 1.65 1.83 1.6 1.9 1.7 1.9 1.7 1.85 1.65 1.90 1.69 1.92 1.71 10.7 11.3 12.3 13.1 13.2 14.0 13.6 14.5 15.0 15.9 16.0 17.0 16.6 17.6 17.7 18.8 18.9 20.0 19.5 20.7 20.4 21.6 21.7 23.1 22.5 23.9 23.1 24.5 24.7 26.2 25.5 27.1 25.8 27.4 27.6 29.3 28.6 30.4 27.2 28.9 29.1 30.9 30.2 32.1 28.6 30.4 30.6 32.5 31.8 33.8 91.4 86.0 93.7 87.8 94.9 88.6 95.6 89.1 97.5 90.6 98.9 91.6 99.7 92.2 101.2 93.4 102.9 94.6 103.9 95.3 105.0 96.2 107.0 97.7 108.1 98.5 108.9 99.1 111.2 100.8 112.4 101.7 112.8 102.0 115.5 104.0 116.9 105.1 114.9 103.5 117.7 105.7 119.3 106.9 116.9 105.1 119.9 107.3 121.6 108.6 2.7 3.2 3.0 3.6 3.2 3.7 3.2 3.8 3.5 4.1 3.6 4.3 3.7 4.4 3.9 4.6 4.1 4.8 4.2 4.9 4.3 5.1 4.5 5.3 4.7 5.5 4.7 5.6 5.0 5.8 5.1 6.0 5.1 6.0 5.3 6.3 5.4 6.4 5.3 6.2 5.5 6.5 5.6 6.6 5.4 6.4 5.7 6.6 5.8 6.8 1.7 1.5 2.0 1.8 2.1 1.9 2.1 1.9 2.4 2.1 2.6 2.3 2.6 2.3 2.8 2.5 2.9 2.6 3.0 2.7 3.1 2.8 3.4 3.0 3.5 3.1 3.6 3.2 3.8 3.4 3.9 3.5 3.9 3.5 4.2 3.7 4.3 3.8 4.1 3.7 4.3 3.9 4.4 4.0 4.3 3.8 4.5 4.0 4.6 4.1 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 15 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TS H/V/D 024 (ECM Blower) 950 CFM Nominal (Rated) Airflow Cooling, 950 CFM Nominal (Rated) Airflow Heating WPD EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 GPM 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 PSI FT Airflow CFM 1.9 1.9 0.9 0.9 1.2 1.2 1.7 1.7 0.7 0.7 1.0 1.0 1.6 1.6 0.5 0.5 0.9 0.9 1.5 1.5 0.4 0.4 0.8 0.8 1.4 1.4 0.3 0.3 0.7 0.7 1.3 1.3 0.2 0.2 0.7 0.7 1.2 1.2 0.2 0.2 0.6 0.6 1.1 1.1 0.1 0.1 0.6 0.6 1.1 1.1 0.1 0.1 0.5 0.5 1.0 1.0 0.0 0.0 0.5 0.5 0.8 0.8 0.0 0.0 0.3 0.3 0.6 0.6 4.4 4.4 2.1 2.1 2.7 2.7 4.0 4.0 1.5 1.5 2.4 2.4 3.6 3.6 1.2 1.2 2.1 2.1 3.3 3.3 0.9 0.9 1.8 1.8 3.1 3.1 0.6 0.6 1.7 1.7 2.9 2.9 0.5 0.5 1.5 1.5 2.7 2.7 0.4 0.4 1.5 1.5 2.6 2.6 0.3 0.3 1.4 1.4 2.5 2.5 0.2 0.2 1.2 1.2 2.2 2.2 0.1 0.1 1.0 1.0 1.9 1.9 0.0 0.0 0.8 0.8 1.5 1.5 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 TC Cooling - EAT 80/67°F Sens/ SC Tot kW HR Ratio Performance capacities shown in thousands of Btuh Heating - EAT 70°F EER HWC 32.5 33.4 34.4 35.3 34.9 35.9 29.3 30.1 31.9 32.8 32.8 33.7 25.5 26.2 28.3 29.1 29.6 30.5 21.8 22.5 24.6 25.3 26.1 26.8 18.5 19.0 21.0 21.6 22.3 22.9 15.4 15.8 17.4 17.9 18.7 19.2 14.0 14.4 15.9 16.4 17.0 17.5 12.7 13.0 14.4 14.8 15.4 15.8 10.4 10.7 11.8 12.1 12.5 12.9 8.5 8.7 9.6 9.8 10.2 10.5 7.0 7.2 7.8 8.0 8.2 8.5 0.8 0.8 0.7 0.7 0.6 0.6 1.0 1.1 0.9 0.9 0.8 0.8 1.4 1.5 1.1 1.2 1.0 1.1 1.8 1.9 1.5 1.6 1.3 1.4 2.3 2.4 1.9 2.0 1.8 1.9 2.9 3.0 2.5 2.6 2.3 2.4 3.2 3.4 2.8 2.9 2.6 2.7 3.5 3.7 3.0 3.2 2.9 3.0 4.2 4.4 3.7 3.9 3.5 3.7 5.0 5.3 4.6 4.8 4.3 4.5 6.0 6.3 5.4 5.7 5.1 5.4 Operation not recommended 28.1 30.4 27.5 29.7 26.9 29.1 28.1 30.4 28.2 30.5 28.1 30.4 27.4 29.6 28.0 30.3 28.2 30.5 26.2 28.3 27.1 29.3 27.5 29.8 24.6 26.6 25.8 27.8 26.3 28.4 22.8 24.7 24.1 26.0 24.7 26.7 21.9 23.7 23.1 25.0 23.7 25.7 21.0 22.7 22.2 24.0 22.8 24.7 19.2 20.7 20.3 21.9 20.9 22.6 17.5 18.9 18.5 20.0 19.0 20.5 16.2 17.5 16.9 18.3 17.3 18.7 16.5 19.4 15.6 18.3 14.9 17.6 17.1 20.2 16.7 19.7 16.4 19.3 17.2 20.2 17.2 20.2 17.1 20.1 16.8 19.7 17.1 20.1 17.2 20.2 16.1 19.0 16.6 19.5 16.8 19.8 15.4 18.1 15.9 18.7 16.2 19.0 14.9 17.6 15.5 18.2 15.8 18.5 14.5 17.1 15.1 17.7 15.4 18.1 13.8 16.2 14.2 16.7 14.5 17.1 13.2 15.5 13.5 15.9 13.7 16.1 12.9 15.1 13.0 15.3 13.1 15.4 0.59 0.64 0.57 0.62 0.56 0.60 0.61 0.66 0.59 0.65 0.58 0.64 0.63 0.68 0.61 0.67 0.61 0.66 0.64 0.70 0.63 0.69 0.62 0.68 0.66 0.71 0.65 0.70 0.64 0.70 0.67 0.73 0.66 0.72 0.66 0.71 0.68 0.74 0.67 0.73 0.66 0.72 0.69 0.75 0.68 0.74 0.67 0.73 0.72 0.78 0.70 0.76 0.69 0.76 0.75 0.82 0.73 0.80 0.72 0.78 0.79 0.86 0.77 0.84 0.76 0.82 0.87 0.91 0.80 0.84 0.77 0.81 0.96 1.01 0.88 0.93 0.86 0.90 1.07 1.13 0.99 1.04 0.95 1.00 1.20 1.26 1.10 1.16 1.06 1.11 1.33 1.40 1.23 1.29 1.18 1.24 1.48 1.56 1.38 1.45 1.32 1.39 1.6 1.65 1.46 1.54 1.40 1.48 1.65 1.74 1.54 1.62 1.48 1.56 1.84 1.94 1.72 1.81 1.66 1.75 2.07 2.18 1.93 2.03 1.86 1.96 2.32 2.44 2.17 2.28 2.10 2.21 31.8 33.5 30.9 32.5 30.2 31.8 32.2 33.9 32.0 33.7 31.7 33.4 31.8 33.5 32.2 33.8 32.2 33.9 30.9 32.6 31.6 33.3 31.9 33.6 29.8 31.4 30.6 32.3 31.0 32.7 28.5 30.0 29.4 30.9 29.8 31.4 27.8 29.3 28.7 30.2 29.2 30.7 27.2 28.6 28.0 29.5 28.5 30.0 26.0 27.3 26.7 28.1 27.1 28.5 25.0 26.4 25.6 26.9 25.9 27.2 24.6 25.8 24.8 26.1 25.0 26.3 Airflow CFM HC kW HE LAT COP HWC 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 680 950 15.4 16.1 17.1 17.8 17.9 18.7 18.4 19.2 19.8 20.7 20.8 21.7 21.3 22.3 22.5 23.5 23.7 24.7 24.3 25.4 25.2 26.4 26.6 27.8 27.4 28.6 28.0 29.3 29.6 31.0 30.5 31.9 30.9 32.2 32.7 34.2 33.8 35.3 32.3 33.8 34.4 35.9 35.5 37.1 33.8 35.3 36.0 37.6 37.2 38.9 1.64 1.46 1.65 1.47 1.65 1.47 1.65 1.47 1.66 1.48 1.66 1.48 1.67 1.49 1.67 1.49 1.69 1.50 1.69 1.50 1.70 1.51 1.71 1.52 1.72 1.53 1.72 1.53 1.74 1.55 1.75 1.56 1.76 1.57 1.80 1.60 1.81 1.61 1.79 1.6 1.8 1.6 1.8 1.6 1.81 1.61 1.85 1.65 1.89 1.68 10.4 11.1 12.1 12.8 12.9 13.7 13.3 14.2 14.7 15.6 15.7 16.7 16.2 17.2 17.3 18.4 18.5 19.6 19.1 20.3 20.0 21.2 21.3 22.6 22.0 23.4 22.6 24.0 24.2 25.7 25.0 26.6 25.3 26.9 27.1 28.8 28.1 29.8 26.7 28.4 28.6 30.4 29.6 31.5 28.1 29.8 30.1 31.9 31.2 33.1 90.9 85.7 93.3 87.4 94.4 88.2 95.0 88.7 96.9 90.1 98.3 91.2 99.0 91.7 100.6 92.9 102.2 94.1 103.1 94.8 104.3 95.7 106.2 97.1 107.3 97.9 108.1 98.5 110.3 100.2 111.6 101.1 112.0 101.4 114.6 103.3 116.0 104.4 114.0 102.9 116.8 105.0 118.3 106.1 116.0 104.4 119.0 106.6 120.7 107.9 2.7 3.2 3.0 3.6 3.2 3.7 3.3 3.8 3.5 4.1 3.7 4.3 3.7 4.4 3.9 4.6 4.1 4.8 4.2 5.0 4.4 5.1 4.6 5.4 4.7 5.5 4.8 5.6 5.0 5.9 5.1 6.0 5.1 6.0 5.3 6.3 5.5 6.4 5.3 6.2 5.5 6.5 5.6 6.6 5.5 6.4 5.7 6.7 5.8 6.8 1.7 1.5 2.0 1.8 2.1 1.9 2.1 1.9 2.4 2.1 2.6 2.3 2.6 2.3 2.8 2.5 2.9 2.6 3.0 2.7 3.1 2.8 3.4 3.0 3.5 3.1 3.6 3.2 3.8 3.4 3.9 3.5 3.9 3.5 4.2 3.7 4.3 3.8 4.1 3.7 4.3 3.9 4.4 4.0 4.3 3.8 4.5 4.0 4.6 4.1 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 16 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TS H/V/D 030 (PSC Blower) 1000 CFM Nominal (Rated) Airflow Cooling,1000 CFM Nominal (Rated) Airflow Heating WPD EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 GPM 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 PSI FT Airflow CFM 2.7 2.7 0.9 0.9 1.6 1.6 2.5 2.5 0.8 0.8 1.5 1.5 2.3 2.3 0.8 0.8 1.4 1.4 2.2 2.2 0.7 0.7 1.3 1.3 2.1 2.1 0.7 0.7 1.3 1.3 2.0 2.0 0.7 0.7 1.3 1.3 2.0 2.0 0.7 0.7 1.3 1.3 2.0 2.0 0.7 0.7 1.3 1.3 2.0 2.0 0.7 0.7 1.3 1.3 1.9 1.9 0.7 0.7 1.2 1.2 1.9 1.9 0.7 0.7 1.2 1.2 1.9 1.9 6.2 6.2 2.0 2.0 3.6 3.6 5.7 5.7 1.8 1.8 3.4 3.4 5.3 5.3 1.8 1.8 3.2 3.2 5.0 5.0 1.7 1.7 3.1 3.1 4.8 4.8 1.7 1.7 3.0 3.0 4.7 4.7 1.7 1.7 3.0 3.0 4.6 4.6 1.7 1.7 2.9 2.9 4.6 4.6 1.7 1.7 2.9 2.9 4.5 4.5 1.7 1.7 2.9 2.9 4.5 4.5 1.7 1.7 2.8 2.8 4.4 4.4 1.6 1.6 2.8 2.8 4.3 4.3 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 TC Cooling - EAT 80/67°F Sens/ SC Tot kW HR Ratio Performance capacities shown in thousands of Btuh Heating - EAT 70°F EER HWC Operation not recommended 31.8 34.4 30.9 33.4 30.2 32.6 32.1 34.7 32.0 34.6 31.8 34.4 31.5 34.0 32.0 34.6 32.1 34.7 30.2 32.6 31.1 33.7 31.5 34.1 28.5 30.8 29.7 32.1 30.2 32.7 26.5 28.7 27.8 30.1 28.5 30.8 25.5 27.6 26.8 29.0 27.4 29.7 24.5 26.5 25.8 27.9 26.4 28.6 22.5 24.3 23.7 25.6 24.3 26.3 20.7 22.4 21.7 23.5 22.2 24.0 19.3 20.9 20.0 21.7 20.5 22.1 18.2 21.4 17.3 20.4 16.7 19.7 18.8 22.1 18.4 21.7 18.1 21.3 18.8 22.1 18.8 22.2 18.8 22.1 18.4 21.6 18.7 22.0 18.8 22.1 17.7 20.9 18.2 21.4 18.4 21.7 16.9 19.9 17.5 20.5 17.7 20.9 16.5 19.4 17.0 20.0 17.3 20.4 16.1 18.9 16.6 19.5 16.9 19.9 15.3 18.0 15.8 18.5 16.0 18.8 14.7 17.3 15.0 17.7 15.2 17.9 14.4 17.0 14.5 17.1 14.6 17.2 0.57 0.62 0.56 0.61 0.55 0.60 0.58 0.64 0.58 0.63 0.57 0.62 0.60 0.65 0.59 0.64 0.58 0.64 0.61 0.66 0.60 0.65 0.60 0.65 0.62 0.68 0.61 0.67 0.61 0.66 0.64 0.69 0.63 0.68 0.62 0.68 0.65 0.70 0.64 0.69 0.63 0.69 0.66 0.71 0.64 0.70 0.64 0.70 0.68 0.74 0.67 0.72 0.66 0.72 0.71 0.77 0.69 0.75 0.68 0.74 0.75 0.81 0.73 0.79 0.72 0.78 1.14 1.20 1.07 1.13 1.05 1.10 1.26 1.32 1.18 1.24 1.14 1.20 1.39 1.46 1.29 1.36 1.26 1.32 1.52 1.60 1.43 1.50 1.38 1.45 1.68 1.77 1.58 1.66 1.52 1.60 1.86 1.96 1.74 1.83 1.68 1.77 2.0 2.07 1.84 1.93 1.78 1.87 2.06 2.17 1.93 2.03 1.87 1.97 2.28 2.40 2.15 2.26 2.08 2.19 2.55 2.68 2.40 2.52 2.32 2.44 2.84 2.99 2.67 2.81 2.60 2.73 36.6 38.5 35.4 37.2 34.6 36.4 37.3 39.2 36.9 38.9 36.5 38.5 37.1 39.0 37.3 39.3 37.3 39.2 36.2 38.1 36.8 38.8 37.1 39.0 35.0 36.8 35.9 37.7 36.2 38.1 33.6 35.4 34.5 36.3 35.0 36.8 32.9 34.6 33.8 35.6 34.3 36.1 32.2 33.9 33.1 34.8 33.5 35.3 30.9 32.5 31.6 33.3 32.0 33.7 29.9 31.5 30.4 32.0 30.7 32.4 29.5 31.1 29.7 31.2 29.8 31.4 27.9 28.7 28.7 29.5 28.9 29.7 25.6 26.3 27.2 27.9 27.9 28.6 22.7 23.3 24.7 25.4 25.6 26.3 19.8 20.4 21.8 22.4 22.9 23.5 16.9 17.4 18.8 19.3 19.9 20.4 14.2 14.6 16.0 16.4 16.9 17.4 13.1 13.4 14.7 15.1 15.5 15.9 11.9 12.2 13.3 13.7 14.1 14.5 9.9 10.1 11.0 11.3 11.7 12.0 8.1 8.4 9.1 9.3 9.6 9.9 6.8 7.0 7.5 7.7 7.9 8.1 0.8 0.8 0.7 0.7 0.6 0.6 1.0 1.1 0.9 0.9 0.8 0.8 1.3 1.4 1.1 1.2 1.0 1.0 1.7 1.8 1.4 1.5 1.3 1.4 2.2 2.3 1.9 2.0 1.7 1.8 2.8 2.9 2.4 2.5 2.2 2.3 3.1 3.3 2.7 2.9 2.5 2.7 3.4 3.6 3.0 3.2 2.9 3.0 4.1 4.3 3.7 3.9 3.5 3.7 4.9 5.2 4.5 4.7 4.3 4.5 5.9 6.2 5.3 5.6 5.1 5.4 Airflow CFM 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 HC kW HE LAT COP HWC 18.6 19.4 20.7 21.6 21.6 22.6 22.1 23.1 23.9 25.0 25.1 26.2 25.7 26.8 27.2 28.4 28.5 29.8 29.3 30.6 30.4 31.8 32.0 33.4 32.8 34.3 33.7 35.2 35.4 37.0 36.4 38.0 36.9 38.6 38.8 40.6 39.9 41.7 38.5 40.2 40.5 42.3 41.6 43.5 40.1 41.9 42.2 44.1 43.3 45.3 2.06 1.83 2.10 1.87 2.11 1.88 2.12 1.89 2.15 1.91 2.16 1.92 2.17 1.93 2.18 1.94 2.20 1.96 2.20 1.96 2.21 1.97 2.24 1.99 2.25 2.00 2.26 2.01 2.28 2.03 2.29 2.04 2.30 2.05 2.34 2.08 2.36 2.10 2.33 2.1 2.4 2.1 2.4 2.1 2.36 2.10 2.42 2.15 2.45 2.18 12.4 13.2 14.3 15.2 15.2 16.2 15.7 16.7 17.4 18.5 18.5 19.6 19.1 20.3 20.5 21.8 21.8 23.1 22.5 23.9 23.6 25.1 25.1 26.6 25.9 27.5 26.7 28.4 28.3 30.1 29.2 31.0 29.8 31.6 31.5 33.5 32.5 34.5 31.2 33.2 33.1 35.1 34.1 36.2 32.7 34.7 34.6 36.8 35.6 37.8 93.9 88.0 96.6 90.0 97.8 90.9 98.4 91.4 100.8 93.1 102.2 94.2 103.0 94.9 105.0 96.3 106.7 97.6 107.6 98.3 109.1 99.5 111.1 100.9 112.2 101.8 113.3 102.6 115.5 104.3 116.8 105.2 117.5 105.7 119.9 107.6 121.3 108.6 119.5 107.3 122.1 109.2 123.5 110.2 121.6 108.8 124.3 110.8 125.7 111.9 2.6 3.1 2.9 3.4 3.0 3.5 3.1 3.6 3.3 3.8 3.4 4.0 3.5 4.1 3.7 4.3 3.8 4.5 3.9 4.6 4.0 4.7 4.2 4.9 4.3 5.0 4.4 5.1 4.5 5.3 4.6 5.5 4.7 5.5 4.9 5.7 4.9 5.8 4.8 5.7 5.0 5.9 5.1 6.0 5.0 5.9 5.1 6.0 5.2 6.1 1.7 1.5 1.9 1.7 2.0 1.8 2.1 1.9 2.2 2.0 2.5 2.2 2.6 2.3 2.7 2.4 2.9 2.6 3.0 2.7 3.0 2.7 3.3 2.9 3.4 3.0 3.4 3.0 3.7 3.3 3.8 3.4 3.8 3.4 4.0 3.6 4.2 3.7 4.0 3.6 4.2 3.8 4.4 3.9 4.2 3.7 4.4 3.9 4.6 4.1 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 17 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TS H/V/D 030 (ECM Blower) 1,000 CFM Nominal (Rated) Airflow Cooling, 1,100 CFM Nominal (Rated) Airflow Heating WPD EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 GPM 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 PSI FT Airflow CFM 2.7 2.7 0.9 0.9 1.6 1.6 2.5 2.5 0.8 0.8 1.5 1.5 2.3 2.3 0.8 0.8 1.4 1.4 2.2 2.2 0.7 0.7 1.3 1.3 2.1 2.1 0.7 0.7 1.3 1.3 2.0 2.0 0.7 0.7 1.3 1.3 2.0 2.0 0.7 0.7 1.3 1.3 2.0 2.0 0.7 0.7 1.3 1.3 2.0 2.0 0.7 0.7 1.3 1.3 1.9 1.9 0.7 0.7 1.2 1.2 1.9 1.9 0.7 0.7 1.2 1.2 1.9 1.9 6.2 6.2 2.0 2.0 3.6 3.6 5.7 5.7 1.8 1.8 3.4 3.4 5.3 5.3 1.8 1.8 3.2 3.2 5.0 5.0 1.7 1.7 3.1 3.1 4.8 4.8 1.7 1.7 3.0 3.0 4.7 4.7 1.7 1.7 3.0 3.0 4.6 4.6 1.7 1.7 2.9 2.9 4.6 4.6 1.7 1.7 2.9 2.9 4.5 4.5 1.7 1.7 2.9 2.9 4.5 4.5 1.7 1.7 2.8 2.8 4.4 4.4 1.6 1.6 2.8 2.8 4.3 4.3 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 720 1000 TC Cooling - EAT 80/67°F Sens/ SC Tot kW HR Ratio Performance capacities shown in thousands of Btuh Heating - EAT 70°F EER HWC Operation not recommended 31.8 34.4 30.9 33.4 30.2 32.6 32.1 34.7 32.0 34.6 31.8 34.4 31.5 34.0 32.0 34.6 32.1 34.7 30.2 32.7 31.1 33.7 31.5 34.1 28.5 30.8 29.7 32.1 30.2 32.7 26.6 28.7 27.8 30.1 28.5 30.8 25.5 27.6 26.8 29.0 27.5 29.7 24.5 26.5 25.8 27.9 26.4 28.6 22.5 24.3 23.7 25.6 24.3 26.3 20.7 22.4 21.7 23.5 22.2 24.1 19.3 20.9 20.0 21.7 20.5 22.1 18.2 21.4 17.3 20.3 16.7 19.7 18.8 22.1 18.4 21.7 18.1 21.3 18.8 22.1 18.8 22.2 18.8 22.1 18.4 21.6 18.7 22.0 18.8 22.1 17.7 20.9 18.2 21.4 18.4 21.7 16.9 19.9 17.5 20.6 17.7 20.9 16.5 19.4 17.0 20.1 17.3 20.4 16.1 18.9 16.6 19.6 16.9 19.9 15.3 18.0 15.8 18.5 16.0 18.8 14.7 17.3 15.0 17.7 15.2 17.9 14.4 17.0 14.5 17.1 14.6 17.2 0.57 0.62 0.56 0.61 0.55 0.60 0.58 0.64 0.58 0.63 0.57 0.62 0.60 0.65 0.59 0.64 0.58 0.64 0.61 0.66 0.60 0.65 0.60 0.65 0.62 0.68 0.61 0.67 0.61 0.66 0.64 0.69 0.63 0.68 0.62 0.68 0.65 0.70 0.64 0.69 0.63 0.69 0.66 0.71 0.64 0.70 0.64 0.70 0.68 0.74 0.67 0.72 0.66 0.72 0.71 0.77 0.69 0.75 0.68 0.74 0.75 0.81 0.72 0.79 0.71 0.78 1.10 1.16 1.04 1.09 1.01 1.06 1.22 1.28 1.14 1.20 1.10 1.16 1.35 1.42 1.26 1.32 1.22 1.28 1.48 1.56 1.39 1.46 1.34 1.41 1.65 1.73 1.54 1.62 1.48 1.56 1.82 1.91 1.70 1.79 1.65 1.73 1.9 2.02 1.80 1.89 1.74 1.83 2.02 2.12 1.89 1.99 1.84 1.93 2.24 2.36 2.11 2.22 2.04 2.15 2.51 2.64 2.36 2.48 2.28 2.40 2.81 2.95 2.63 2.77 2.55 2.68 36.4 38.4 35.2 37.1 34.4 36.2 37.2 39.1 36.8 38.7 36.4 38.3 36.9 38.9 37.2 39.1 37.1 39.1 36.1 38.0 36.7 38.7 36.9 38.9 34.9 36.7 35.7 37.6 36.1 38.0 33.5 35.2 34.4 36.2 34.9 36.7 32.8 34.5 33.7 35.4 34.1 35.9 32.1 33.8 32.9 34.7 33.4 35.2 30.8 32.4 31.5 33.2 31.9 33.6 29.8 31.4 30.3 31.9 30.6 32.2 29.4 31.0 29.6 31.1 29.7 31.3 28.8 29.6 29.8 30.6 29.9 30.8 26.4 27.1 28.1 28.9 28.8 29.6 23.3 24.0 25.5 26.2 26.4 27.1 20.4 20.9 22.4 23.1 23.5 24.2 17.3 17.8 19.3 19.8 20.4 21.0 14.6 15.0 16.4 16.8 17.3 17.8 13.4 13.8 15.0 15.4 15.9 16.3 12.2 12.5 13.6 14.0 14.4 14.8 10.0 10.3 11.2 11.5 11.9 12.2 8.3 8.5 9.2 9.5 9.7 10.0 6.9 7.1 7.6 7.8 8.0 8.3 0.8 0.8 0.7 0.7 0.6 0.6 1.0 1.1 0.9 0.9 0.8 0.8 1.3 1.4 1.1 1.2 1.0 1.0 1.7 1.8 1.4 1.5 1.3 1.4 2.2 2.3 1.9 2.0 1.7 1.8 2.8 2.9 2.4 2.5 2.2 2.3 3.1 3.3 2.7 2.9 2.5 2.7 3.4 3.6 3.0 3.2 2.9 3.0 4.1 4.3 3.7 3.9 3.5 3.7 4.9 5.2 4.5 4.7 4.3 4.5 5.9 6.2 5.3 5.6 5.1 5.4 Airflow CFM 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 790 1100 HC kW HE LAT COP HWC 18.8 19.7 20.9 21.9 21.9 22.9 22.4 23.4 24.2 25.3 25.4 26.5 26.0 27.2 27.5 28.7 28.9 30.2 29.6 31.0 30.8 32.2 32.4 33.8 33.2 34.7 34.1 35.6 35.8 37.4 36.8 38.5 37.3 39.0 39.3 41.0 40.3 42.1 38.9 40.7 41.0 42.8 42.1 44.0 40.6 42.4 42.7 44.6 43.8 45.8 2.09 1.86 2.12 1.89 2.15 1.91 2.15 1.91 2.18 1.94 2.19 1.95 2.20 1.96 2.21 1.97 2.23 1.98 2.24 1.99 2.25 2.00 2.27 2.02 2.27 2.02 2.28 2.03 2.30 2.05 2.33 2.07 2.33 2.07 2.37 2.11 2.39 2.13 2.36 2.1 2.4 2.1 2.4 2.2 2.39 2.13 2.45 2.18 2.48 2.21 12.6 13.3 14.5 15.4 15.4 16.4 15.9 16.9 17.6 18.7 18.7 19.9 19.3 20.5 20.7 22.0 22.1 23.4 22.8 24.2 23.9 25.4 25.4 26.9 26.2 27.8 27.0 28.7 28.7 30.4 29.6 31.4 30.1 31.9 31.9 33.9 32.9 34.9 31.6 33.5 33.4 35.5 34.5 36.6 33.1 35.1 35.0 37.2 36.0 38.2 92.1 86.6 94.5 88.4 95.7 89.3 96.3 89.7 98.4 91.3 99.7 92.3 100.5 92.9 102.2 94.2 103.8 95.4 104.7 96.1 106.1 97.1 107.9 98.5 108.9 99.2 109.9 100.0 112.0 101.5 113.1 102.4 113.8 102.8 116.0 104.5 117.3 105.5 115.6 104.3 118.0 106.0 119.3 107.0 117.5 105.7 120.0 107.5 121.3 108.5 2.6 3.1 2.9 3.4 3.0 3.5 3.1 3.6 3.3 3.8 3.4 4.0 3.5 4.1 3.6 4.3 3.8 4.5 3.9 4.6 4.0 4.7 4.2 4.9 4.3 5.0 4.4 5.1 4.6 5.4 4.6 5.4 4.7 5.5 4.9 5.7 4.9 5.8 4.8 5.7 5.0 5.9 5.1 5.9 5.0 5.8 5.1 6.0 5.2 6.1 1.7 1.5 1.9 1.7 2.0 1.8 2.1 1.9 2.2 2.0 2.5 2.2 2.6 2.3 2.7 2.4 2.9 2.6 3.0 2.7 3.0 2.7 3.3 2.9 3.4 3.0 3.4 3.0 3.7 3.3 3.8 3.4 3.8 3.4 4.0 3.6 4.2 3.7 4.0 3.6 4.2 3.8 4.4 3.9 4.2 3.7 4.4 3.9 4.6 4.1 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 18 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TS H/V/D 036 (PSC Blower) 1,200 CFM Nominal (Rated) Airflow Cooling, 1,200 CFM Nominal (Rated) Airflow Heating WPD EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 GPM 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 PSI FT Airflow CFM 4.3 4.3 1.2 1.2 2.4 2.4 3.8 3.8 1.0 1.0 2.1 2.1 3.4 3.4 0.9 0.9 1.9 1.9 3.2 3.2 0.8 0.8 1.8 1.8 3.0 3.0 0.8 0.8 1.7 1.7 2.9 2.9 0.8 0.8 1.7 1.7 2.8 2.8 0.8 0.8 1.6 1.6 2.8 2.8 0.8 0.8 1.6 1.6 2.7 2.7 0.8 0.8 1.6 1.6 2.7 2.7 0.7 0.7 1.6 1.6 2.6 2.6 0.6 0.6 1.5 1.5 2.5 2.5 9.9 9.9 2.8 2.8 5.5 5.5 8.8 8.8 2.3 2.3 4.8 4.8 7.9 7.9 2.0 2.0 4.4 4.4 7.3 7.3 1.8 1.8 4.1 4.1 6.9 6.9 1.8 1.8 3.9 3.9 6.6 6.6 1.8 1.8 3.8 3.8 6.4 6.4 1.8 1.8 3.8 3.8 6.4 6.4 1.8 1.8 3.8 3.8 6.3 6.3 1.8 1.8 3.7 3.7 6.2 6.2 1.7 1.7 3.6 3.6 6.1 6.1 1.5 1.5 3.3 3.3 5.8 5.8 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 TC Cooling - EAT 80/67°F Sens/ SC Tot kW HR Ratio Performance capacities shown in thousands of Btuh Heating - EAT 70°F EER HWC Operation not recommended 33.1 35.8 31.2 33.7 30.0 32.5 34.9 37.8 34.0 36.8 33.3 36.0 35.4 38.3 35.2 38.1 35.0 37.8 34.8 37.7 35.3 38.2 35.4 38.3 33.6 36.3 34.5 37.3 34.8 37.6 31.9 34.5 33.0 35.7 33.5 36.3 30.9 33.4 32.1 34.7 32.6 35.3 29.9 32.3 31.1 33.7 31.8 34.3 27.7 30.0 29.0 31.4 29.7 32.1 25.6 27.6 26.8 29.0 27.4 29.7 23.6 25.5 24.7 26.6 25.2 27.3 18.6 21.9 17.2 20.2 16.5 19.4 20.3 23.9 19.4 22.8 18.8 22.1 21.3 25.0 20.7 24.4 20.4 24.0 21.6 25.4 21.5 25.2 21.3 25.0 21.5 25.3 21.6 25.5 21.6 25.4 21.0 24.7 21.4 25.1 21.5 25.3 20.6 24.2 21.0 24.8 21.2 25.0 20.2 23.8 20.7 24.4 21.0 24.7 19.2 22.6 19.8 23.3 20.1 23.7 18.0 21.2 18.7 22.0 19.0 22.4 16.9 19.9 17.5 20.6 17.9 21.0 0.56 0.61 0.55 0.60 0.55 0.60 0.58 0.63 0.57 0.62 0.56 0.61 0.60 0.65 0.59 0.64 0.58 0.63 0.62 0.68 0.61 0.66 0.60 0.65 0.64 0.70 0.63 0.68 0.62 0.68 0.66 0.72 0.65 0.70 0.64 0.70 0.67 0.73 0.66 0.71 0.65 0.71 0.68 0.74 0.67 0.72 0.66 0.72 0.69 0.75 0.68 0.74 0.68 0.74 0.71 0.77 0.70 0.76 0.69 0.76 0.72 0.78 0.71 0.77 0.71 0.77 1.31 1.38 1.26 1.32 1.23 1.29 1.44 1.51 1.36 1.43 1.32 1.39 1.59 1.67 1.49 1.57 1.45 1.52 1.76 1.85 1.65 1.73 1.59 1.67 1.94 2.04 1.82 1.91 1.76 1.85 2.15 2.26 2.02 2.12 1.95 2.05 2.3 2.38 2.13 2.24 2.06 2.17 2.38 2.50 2.23 2.35 2.17 2.28 2.62 2.76 2.47 2.60 2.40 2.52 2.90 3.05 2.74 2.88 2.66 2.80 3.20 3.37 3.03 3.19 2.95 3.10 38.5 40.5 36.3 38.2 35.0 36.9 40.8 42.9 39.6 41.6 38.8 40.8 41.8 44.0 41.3 43.4 40.9 43.0 41.8 44.0 41.8 44.1 41.8 44.0 41.1 43.3 41.6 43.8 41.8 44.0 40.1 42.2 40.8 42.9 41.1 43.3 39.4 41.5 40.2 42.3 40.5 42.7 38.8 40.8 39.6 41.7 40.0 42.1 37.4 39.4 38.2 40.2 38.6 40.7 36.2 38.1 36.9 38.8 37.2 39.2 35.2 37.0 35.7 37.5 36.0 37.9 25.2 25.9 24.8 25.5 24.5 25.2 24.3 25.0 25.0 25.7 25.2 25.9 22.3 22.9 23.6 24.3 24.2 24.9 19.8 20.4 21.5 22.1 22.3 22.9 17.3 17.8 19.0 19.5 19.8 20.3 14.8 15.3 16.4 16.8 17.2 17.7 13.7 14.1 15.2 15.6 15.9 16.4 12.6 12.9 13.9 14.3 14.6 15.1 10.6 10.9 11.7 12.1 12.4 12.7 8.8 9.1 9.8 10.1 10.3 10.6 7.4 7.6 8.1 8.4 8.6 8.8 1.0 1.0 0.8 0.8 0.8 0.8 1.2 1.3 1.0 1.1 1.0 1.0 1.7 1.8 1.4 1.5 1.2 1.3 2.4 2.5 1.9 2.0 1.7 1.8 3.1 3.3 2.6 2.7 2.4 2.5 4.0 4.2 3.4 3.6 3.1 3.3 4.5 4.7 3.9 4.1 3.6 3.8 4.9 5.2 4.4 4.6 4.0 4.2 6.1 6.4 5.4 5.7 5.0 5.3 7.3 7.7 6.7 7.0 6.3 6.6 8.7 9.2 8.0 8.4 7.6 8.0 Airflow CFM 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 HC kW HE LAT COP HWC 22.3 23.3 24.4 25.5 25.3 26.5 25.9 27.1 27.9 29.2 29.2 30.5 29.9 31.3 31.8 33.2 33.3 34.8 34.2 35.8 35.7 37.3 37.6 39.2 38.6 40.3 39.6 41.4 41.6 43.5 42.7 44.6 43.4 45.3 45.4 47.5 46.4 48.5 45.1 47.1 47.0 49.1 48.0 50.1 46.8 48.9 48.6 50.8 49.5 51.8 2.37 2.11 2.38 2.12 2.39 2.13 2.41 2.14 2.43 2.16 2.45 2.18 2.46 2.19 2.48 2.21 2.52 2.24 2.53 2.25 2.55 2.27 2.59 2.30 2.61 2.32 2.63 2.34 2.66 2.37 2.69 2.39 2.70 2.40 2.74 2.44 2.77 2.46 2.74 2.4 2.8 2.5 2.8 2.5 2.78 2.47 2.81 2.50 2.83 2.52 15.2 16.1 17.2 18.2 18.1 19.2 18.6 19.8 20.5 21.8 21.8 23.1 22.4 23.8 24.1 25.6 25.6 27.2 26.5 28.1 27.8 29.6 29.6 31.4 30.5 32.4 31.5 33.5 33.4 35.4 34.4 36.5 35.0 37.1 36.9 39.1 37.8 40.1 36.6 38.8 38.4 40.7 39.2 41.6 38.1 40.5 39.8 42.3 40.7 43.2 94.0 88.0 96.2 89.7 97.3 90.4 97.9 90.9 100.1 92.5 101.5 93.6 102.2 94.1 104.2 95.6 105.9 96.9 106.8 97.6 108.5 98.8 110.4 100.3 111.5 101.1 112.7 102.0 114.8 103.6 116.0 104.4 116.7 105.0 118.9 106.6 120.0 107.4 118.5 106.4 120.6 107.9 121.7 108.7 120.4 107.7 122.4 109.2 123.3 109.9 2.8 3.2 3.0 3.5 3.1 3.6 3.2 3.7 3.4 4.0 3.5 4.1 3.6 4.2 3.7 4.4 3.9 4.6 4.0 4.7 4.1 4.8 4.3 5.0 4.3 5.1 4.4 5.2 4.6 5.4 4.7 5.5 4.7 5.5 4.9 5.7 4.9 5.8 4.8 5.7 5.0 5.8 5.0 5.9 4.9 5.8 5.1 6.0 5.1 6.0 2.4 2.1 2.7 2.4 2.9 2.6 3.0 2.7 3.3 2.9 3.5 3.1 3.6 3.2 3.8 3.4 4.0 3.6 4.2 3.7 4.4 3.9 4.6 4.1 4.7 4.2 4.9 4.4 5.2 4.6 5.3 4.7 5.4 4.8 5.7 5.1 5.8 5.2 5.7 5.1 6.0 5.3 6.1 5.5 6.0 5.3 6.2 5.5 6.4 5.7 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 19 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TS H/V/D 036 (ECM Blower) 1,200 CFM Nominal (Rated) Airflow Cooling, 1,200 CFM Nominal (Rated) Airflow Heating WPD EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 GPM 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 PSI FT Airflow CFM 4.3 4.3 1.2 1.2 2.4 2.4 3.8 3.8 1.0 1.0 2.1 2.1 3.4 3.4 0.9 0.9 1.9 1.9 3.2 3.2 0.8 0.8 1.8 1.8 3.0 3.0 0.8 0.8 1.7 1.7 2.9 2.9 0.8 0.8 1.7 1.7 2.8 2.8 0.8 0.8 1.6 1.6 2.8 2.8 0.8 0.8 1.6 1.6 2.7 2.7 0.8 0.8 1.6 1.6 2.7 2.7 0.7 0.7 1.6 1.6 2.6 2.6 0.6 0.6 1.5 1.5 2.5 2.5 9.9 9.9 2.8 2.8 5.5 5.5 8.8 8.8 2.3 2.3 4.8 4.8 7.9 7.9 2.0 2.0 4.4 4.4 7.3 7.3 1.8 1.8 4.1 4.1 6.9 6.9 1.8 1.8 3.9 3.9 6.6 6.6 1.8 1.8 3.8 3.8 6.4 6.4 1.8 1.8 3.8 3.8 6.4 6.4 1.8 1.8 3.8 3.8 6.3 6.3 1.8 1.8 3.7 3.7 6.2 6.2 1.7 1.7 3.6 3.6 6.1 6.1 1.5 1.5 3.3 3.3 5.8 5.8 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 TC Cooling - EAT 80/67°F Sens/ SC Tot kW HR Ratio Performance capacities shown in thousands of Btuh Heating - EAT 70°F EER HWC Operation not recommended 34.1 36.9 32.2 34.8 31.0 33.5 36.0 39.0 35.1 37.9 34.4 37.2 36.5 39.4 36.3 39.3 36.1 39.0 35.9 38.9 36.4 39.3 36.5 39.4 34.7 37.5 35.6 38.5 35.9 38.8 32.9 35.6 34.1 36.8 34.6 37.4 31.9 34.4 33.1 35.8 33.7 36.4 30.8 33.3 32.1 34.7 32.8 35.4 28.6 30.9 29.9 32.4 30.6 33.1 26.3 28.4 27.6 29.8 28.3 30.6 24.1 26.1 25.3 27.3 25.9 28.0 19.3 22.7 17.5 20.6 16.5 19.5 21.5 25.3 20.3 23.9 19.6 23.0 22.7 26.7 22.0 25.9 21.6 25.4 23.1 27.2 22.9 27.0 22.7 26.7 22.9 27.0 23.1 27.2 23.1 27.2 22.3 26.3 22.8 26.8 22.9 27.0 21.9 25.7 22.4 26.3 22.6 26.6 21.4 25.2 22.0 25.9 22.3 26.2 20.4 24.0 21.0 24.7 21.3 25.1 19.2 22.6 19.9 23.4 20.2 23.8 18.2 21.4 18.8 22.1 19.1 22.4 0.57 0.62 0.54 0.59 0.53 0.58 0.60 0.65 0.58 0.63 0.57 0.62 0.62 0.68 0.61 0.66 0.60 0.65 0.64 0.70 0.63 0.69 0.62 0.68 0.66 0.72 0.65 0.71 0.64 0.70 0.68 0.74 0.67 0.73 0.66 0.72 0.69 0.75 0.68 0.74 0.67 0.73 0.70 0.76 0.68 0.75 0.68 0.74 0.71 0.78 0.70 0.76 0.70 0.76 0.73 0.80 0.72 0.78 0.72 0.78 0.75 0.82 0.74 0.81 0.74 0.80 1.08 1.14 1.01 1.06 0.98 1.03 1.22 1.28 1.13 1.19 1.09 1.15 1.37 1.44 1.26 1.33 1.22 1.28 1.53 1.61 1.42 1.49 1.37 1.44 1.72 1.81 1.60 1.68 1.53 1.61 1.92 2.02 1.79 1.88 1.72 1.81 2.0 2.14 1.90 2.00 1.83 1.92 2.15 2.26 2.01 2.11 1.93 2.03 2.40 2.52 2.24 2.36 2.17 2.28 2.67 2.81 2.51 2.64 2.43 2.55 2.98 3.13 2.81 2.95 2.72 2.86 38.7 40.8 36.5 38.4 35.2 37.0 41.1 43.3 39.9 41.9 39.0 41.1 42.1 44.3 41.6 43.8 41.2 43.4 42.1 44.3 42.2 44.4 42.1 44.4 41.5 43.6 42.0 44.2 42.1 44.3 40.3 42.5 41.1 43.3 41.4 43.6 39.7 41.7 40.5 42.6 40.8 43.0 39.0 41.0 39.8 41.9 40.3 42.4 37.5 39.5 38.4 40.4 38.8 40.9 36.1 38.0 36.9 38.8 37.3 39.3 34.9 36.8 35.5 37.4 35.9 37.8 31.5 32.4 31.9 32.8 31.7 32.5 29.6 30.4 31.0 31.8 31.4 32.3 26.6 27.4 28.7 29.5 29.6 30.5 23.5 24.1 25.7 26.4 26.6 27.4 20.1 20.7 22.3 22.9 23.5 24.1 17.1 17.6 19.1 19.6 20.1 20.7 15.7 16.2 17.5 18.0 18.5 19.1 14.3 14.7 16.0 16.5 17.0 17.5 11.9 12.3 13.3 13.7 14.1 14.5 9.8 10.1 11.0 11.3 11.7 12.0 8.1 8.3 9.0 9.3 9.5 9.8 1.0 1.0 0.8 0.8 0.8 0.8 1.2 1.3 1.0 1.1 1.0 1.0 1.7 1.8 1.4 1.5 1.2 1.3 2.4 2.5 1.9 2.0 1.7 1.8 3.1 3.3 2.6 2.7 2.4 2.5 4.0 4.2 3.4 3.6 3.1 3.3 4.5 4.7 3.9 4.1 3.6 3.8 4.9 5.2 4.4 4.6 4.0 4.2 6.1 6.4 5.4 5.7 5.0 5.3 7.3 7.7 6.7 7.0 6.3 6.6 8.7 9.2 8.0 8.4 7.6 8.0 Airflow CFM 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 860 1200 HC kW HE LAT COP HWC 21.7 22.7 23.7 24.8 24.7 25.8 25.3 26.4 27.3 28.5 28.6 29.9 29.3 30.6 31.1 32.5 32.7 34.1 33.5 35.0 35.0 36.6 36.8 38.5 37.8 39.5 38.9 40.6 40.9 42.7 41.9 43.8 42.6 44.5 44.6 46.6 45.7 47.7 44.3 46.3 46.3 48.4 47.3 49.4 46.0 48.1 47.9 50.1 48.9 51.0 2.08 1.85 2.10 1.87 2.11 1.88 2.12 1.89 2.15 1.91 2.16 1.92 2.17 1.93 2.20 1.96 2.23 1.98 2.24 1.99 2.26 2.01 2.29 2.04 2.32 2.06 2.33 2.07 2.37 2.11 2.38 2.12 2.41 2.14 2.44 2.17 2.46 2.19 2.43 2.2 2.5 2.2 2.5 2.2 2.46 2.19 2.51 2.23 2.53 2.25 15.4 16.3 17.4 18.4 18.3 19.4 18.8 20.0 20.7 22.0 21.9 23.3 22.6 24.0 24.3 25.8 25.8 27.4 26.6 28.2 28.0 29.7 29.7 31.5 30.6 32.5 31.6 33.5 33.5 35.5 34.4 36.6 35.1 37.2 37.0 39.2 37.9 40.3 36.7 38.9 38.5 40.9 39.4 41.8 38.2 40.6 40.0 42.5 40.9 43.4 93.4 87.5 95.6 89.1 96.6 89.9 97.2 90.4 99.4 92.0 100.8 93.0 101.5 93.6 103.5 95.1 105.2 96.3 106.1 97.0 107.7 98.2 109.6 99.7 110.7 100.5 111.9 101.3 114.0 102.9 115.1 103.8 115.9 104.3 118.1 106.0 119.2 106.8 117.7 105.7 119.8 107.3 120.9 108.1 119.5 107.1 121.6 108.6 122.6 109.4 3.1 3.6 3.3 3.9 3.4 4.0 3.5 4.1 3.7 4.4 3.9 4.6 4.0 4.6 4.1 4.9 4.3 5.1 4.4 5.2 4.5 5.3 4.7 5.5 4.8 5.6 4.9 5.8 5.0 5.9 5.2 6.1 5.2 6.1 5.4 6.3 5.4 6.4 5.3 6.3 5.5 6.4 5.6 6.5 5.5 6.4 5.6 6.6 5.7 6.6 2.4 2.1 2.7 2.4 2.9 2.6 3.0 2.7 3.3 2.9 3.5 3.1 3.6 3.2 3.8 3.4 4.0 3.6 4.2 3.7 4.4 3.9 4.6 4.1 4.7 4.2 4.9 4.4 5.2 4.6 5.3 4.7 5.4 4.8 5.7 5.1 5.8 5.2 5.7 5.1 6.0 5.3 6.1 5.5 6.0 5.3 6.2 5.5 6.4 5.7 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 20 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TS H/V/D 042 (PSC Blower) 1,400 CFM Nominal (Rated) Airflow Cooling, 1,400 CFM Nominal (Rated) Airflow Heating WPD EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 GPM 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 PSI FT Airflow CFM 3.7 3.7 1.0 1.0 2.0 2.0 3.4 3.4 0.9 0.9 1.9 1.9 3.2 3.2 0.8 0.8 1.7 1.7 3.1 3.1 0.8 0.8 1.7 1.7 3.0 3.0 0.8 0.8 1.6 1.6 2.9 2.9 0.8 0.8 1.6 1.6 2.9 2.9 0.8 0.8 1.6 1.6 2.9 2.9 0.8 0.8 1.6 1.6 2.9 2.9 0.8 0.8 1.6 1.6 2.8 2.8 0.8 0.8 1.6 1.6 2.8 2.8 0.7 0.7 1.5 1.5 2.7 2.7 8.5 8.5 2.3 2.3 4.6 4.6 7.9 7.9 2.0 2.0 4.3 4.3 7.5 7.5 1.8 1.8 4.0 4.0 7.1 7.1 1.8 1.8 3.9 3.9 6.9 6.9 1.7 1.7 3.8 3.8 6.7 6.7 1.8 1.8 3.7 3.7 6.7 6.7 1.8 1.8 3.7 3.7 6.6 6.6 1.8 1.8 3.7 3.7 6.6 6.6 1.8 1.8 3.6 3.6 6.5 6.5 1.7 1.7 3.6 3.6 6.4 6.4 1.6 1.6 3.5 3.5 6.3 6.3 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 TC Cooling - EAT 80/67°F Sens/ SC Tot kW HR Ratio Performance capacities shown in thousands of Btuh Heating - EAT 70°F EER HWC Operation not recommended 39.5 42.7 36.4 39.4 34.6 37.4 42.3 45.7 40.9 44.2 39.9 43.1 42.7 46.2 42.7 46.1 42.3 45.8 41.7 45.1 42.5 46.0 42.7 46.2 39.8 43.0 41.1 44.5 41.7 45.1 37.3 40.4 38.9 42.1 39.7 42.9 36.0 38.9 37.6 40.7 38.4 41.5 34.6 37.5 36.3 39.2 37.1 40.1 32.0 34.6 33.5 36.2 34.3 37.1 29.8 32.2 31.0 33.5 31.6 34.2 28.2 30.5 28.9 31.3 29.4 31.8 23.0 27.1 20.1 23.7 18.6 21.8 26.1 30.7 24.5 28.8 23.4 27.5 27.2 32.0 26.7 31.4 26.1 30.8 27.1 31.9 27.3 32.1 27.2 32.0 26.2 30.8 26.8 31.6 27.1 31.9 24.8 29.2 25.7 30.2 26.1 30.7 24.0 28.3 25.0 29.4 25.4 29.9 23.3 27.4 24.2 28.5 24.7 29.0 21.9 25.8 22.7 26.7 23.1 27.2 20.9 24.6 21.4 25.2 21.7 25.5 20.6 24.3 20.7 24.3 20.8 24.4 0.58 0.63 0.55 0.60 0.54 0.58 0.62 0.67 0.60 0.65 0.59 0.64 0.64 0.69 0.63 0.68 0.62 0.67 0.65 0.71 0.64 0.70 0.64 0.69 0.66 0.72 0.65 0.71 0.65 0.71 0.66 0.72 0.66 0.72 0.66 0.72 0.67 0.73 0.66 0.72 0.66 0.72 0.67 0.73 0.67 0.73 0.66 0.72 0.68 0.74 0.68 0.74 0.67 0.73 0.70 0.76 0.69 0.75 0.69 0.75 0.73 0.80 0.71 0.78 0.71 0.77 1.35 1.42 1.26 1.33 1.24 1.30 1.50 1.58 1.41 1.48 1.36 1.43 1.66 1.75 1.56 1.64 1.50 1.58 1.84 1.93 1.72 1.81 1.66 1.75 2.04 2.14 1.90 2.00 1.84 1.94 2.25 2.37 2.11 2.22 2.04 2.15 2.4 2.51 2.23 2.35 2.16 2.27 2.51 2.64 2.35 2.47 2.27 2.39 2.80 2.94 2.62 2.76 2.54 2.67 3.13 3.29 2.94 3.09 2.84 2.99 3.52 3.70 3.30 3.47 3.20 3.36 45.2 47.6 41.7 43.9 39.7 41.8 48.6 51.1 46.8 49.3 45.6 48.0 49.6 52.2 49.1 51.7 48.6 51.2 49.1 51.7 49.5 52.1 49.6 52.2 47.8 50.3 48.7 51.3 49.1 51.7 46.0 48.5 47.2 49.7 47.7 50.3 45.1 47.5 46.2 48.7 46.8 49.3 44.1 46.5 45.3 47.7 45.9 48.3 42.4 44.6 43.4 45.7 43.9 46.2 41.2 43.4 41.8 44.0 42.2 44.4 41.0 43.1 41.0 43.1 41.1 43.2 29.3 30.1 28.8 29.6 28.0 28.7 28.1 28.9 29.1 29.9 29.3 30.2 25.7 26.4 27.3 28.1 28.2 29.0 22.7 23.4 24.7 25.4 25.7 26.4 19.6 20.1 21.6 22.2 22.6 23.2 16.6 17.0 18.4 19.0 19.4 20.0 15.2 15.6 16.9 17.4 17.9 18.4 13.8 14.2 15.4 15.9 16.3 16.8 11.5 11.8 12.8 13.1 13.5 13.9 9.5 9.8 10.5 10.8 11.1 11.4 8.0 8.2 8.8 9.0 9.2 9.5 1.7 1.8 1.8 1.9 1.8 1.9 1.8 1.9 1.7 1.8 1.7 1.8 2.2 2.3 1.9 2.0 1.9 2.0 2.7 2.8 2.4 2.5 2.2 2.3 3.3 3.5 2.9 3.1 2.7 2.8 4.2 4.4 3.6 3.8 3.4 3.6 4.7 4.9 4.1 4.3 3.8 4.1 5.1 5.4 4.6 4.8 4.3 4.5 6.4 6.7 5.6 5.9 5.3 5.6 7.7 8.1 6.9 7.3 6.6 6.9 9.3 9.8 8.4 8.8 8.0 8.4 Airflow CFM 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 HC kW HE LAT COP HWC 26.1 27.2 28.7 30.0 29.9 31.3 30.6 32.0 33.0 34.5 34.6 36.1 35.5 37.1 37.5 39.2 39.4 41.2 40.5 42.3 42.2 44.1 44.4 46.4 45.7 47.7 46.9 49.0 49.5 51.8 51.0 53.3 51.7 54.0 54.7 57.1 56.3 58.8 54.1 56.6 57.2 59.8 58.9 61.6 56.6 59.1 59.8 62.5 61.6 64.4 2.77 2.46 2.75 2.45 2.74 2.44 2.74 2.44 2.74 2.44 2.74 2.44 2.74 2.44 2.75 2.45 2.77 2.46 2.77 2.46 2.79 2.48 2.81 2.50 2.83 2.52 2.84 2.53 2.89 2.57 2.92 2.60 2.93 2.61 3.01 2.68 3.06 2.72 3.00 2.7 3.1 2.7 3.1 2.8 3.06 2.72 3.16 2.81 3.23 2.87 17.7 18.8 20.4 21.6 21.6 23.0 22.3 23.7 24.7 26.2 26.2 27.8 27.1 28.7 29.1 30.9 30.9 32.8 31.9 33.9 33.5 35.6 35.7 37.9 36.9 39.2 38.0 40.4 40.5 43.0 41.8 44.4 42.5 45.1 45.2 48.0 46.7 49.6 44.7 47.5 47.5 50.5 49.1 52.1 46.9 49.8 49.8 52.9 51.4 54.6 94.1 88.0 96.6 89.8 97.7 90.7 98.4 91.2 100.6 92.8 102.0 93.9 102.8 94.5 104.7 95.9 106.5 97.3 107.5 98.0 109.0 99.1 111.1 100.7 112.3 101.6 113.4 102.4 115.9 104.2 117.2 105.2 117.9 105.7 120.6 107.8 122.1 108.9 120.1 107.4 123.0 109.6 124.6 110.7 122.4 109.1 125.4 111.3 127.0 112.6 2.8 3.2 3.1 3.6 3.2 3.8 3.3 3.8 3.5 4.1 3.7 4.3 3.8 4.5 4.0 4.7 4.2 4.9 4.3 5.0 4.4 5.2 4.6 5.4 4.7 5.6 4.8 5.7 5.0 5.9 5.1 6.0 5.2 6.1 5.3 6.2 5.4 6.3 5.3 6.2 5.4 6.4 5.5 6.5 5.4 6.4 5.6 6.5 5.6 6.6 3.7 3.3 3.9 3.5 4.0 3.6 4.0 3.6 4.3 3.8 4.3 3.8 4.4 3.9 4.6 4.1 4.7 4.2 4.7 4.2 4.9 4.4 5.2 4.6 5.3 4.7 5.4 4.8 5.6 5.0 5.7 5.1 6.0 5.3 6.2 5.5 6.4 5.7 6.2 5.6 6.5 5.8 6.7 6.0 6.5 5.8 6.9 6.1 7.1 6.3 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 21 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TS H/V/D 042 (ECM Blower) 1,400 CFM Nominal (Rated) Airflow Cooling, 1,400 CFM Nominal (Rated) Airflow Heating WPD EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 GPM 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 PSI FT Airflow CFM 3.7 3.7 1.0 1.0 2.0 2.0 3.4 3.4 0.9 0.9 1.9 1.9 3.2 3.2 0.8 0.8 1.7 1.7 3.1 3.1 0.8 0.8 1.7 1.7 3.0 3.0 0.8 0.8 1.6 1.6 2.9 2.9 0.8 0.8 1.6 1.6 2.9 2.9 0.8 0.8 1.6 1.6 2.9 2.9 0.8 0.8 1.6 1.6 2.9 2.9 0.8 0.8 1.6 1.6 2.8 2.8 0.8 0.8 1.6 1.6 2.8 2.8 0.7 0.7 1.5 1.5 2.7 2.7 8.5 8.5 2.3 2.3 4.6 4.6 7.9 7.9 2.0 2.0 4.3 4.3 7.5 7.5 1.8 1.8 4.0 4.0 7.1 7.1 1.8 1.8 3.9 3.9 6.9 6.9 1.7 1.7 3.8 3.8 6.7 6.7 1.8 1.8 3.7 3.7 6.7 6.7 1.8 1.8 3.7 3.7 6.6 6.6 1.8 1.8 3.7 3.7 6.6 6.6 1.8 1.8 3.6 3.6 6.5 6.5 1.7 1.7 3.6 3.6 6.4 6.4 1.6 1.6 3.5 3.5 6.3 6.3 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 TC Cooling - EAT 80/67°F Sens/ SC Tot kW HR Ratio Performance capacities shown in thousands of Btuh Heating - EAT 70°F EER HWC Operation not recommended 39.4 42.6 36.3 39.3 34.5 37.3 42.3 45.7 40.9 44.2 39.9 43.1 42.7 46.2 42.6 46.1 42.3 45.7 41.7 45.1 42.5 46.0 42.7 46.2 39.8 43.1 41.2 44.5 41.7 45.1 37.4 40.4 39.0 42.1 39.7 42.9 36.0 39.0 37.6 40.7 38.4 41.6 34.7 37.5 36.3 39.3 37.1 40.2 32.1 34.7 33.6 36.3 34.4 37.1 29.8 32.2 31.0 33.5 31.7 34.2 28.2 30.5 29.0 31.3 29.4 31.8 22.9 27.0 20.1 23.6 18.5 21.8 26.1 30.7 24.4 28.7 23.4 27.5 27.2 32.0 26.6 31.4 26.1 30.7 27.1 31.9 27.3 32.1 27.2 32.0 26.2 30.8 26.8 31.6 27.1 31.9 24.8 29.2 25.7 30.2 26.1 30.7 24.1 28.3 25.0 29.4 25.4 29.9 23.3 27.4 24.2 28.5 24.7 29.1 21.9 25.8 22.7 26.7 23.1 27.2 20.9 24.6 21.4 25.2 21.7 25.6 20.6 24.2 20.7 24.3 20.8 24.5 0.58 0.63 0.55 0.60 0.54 0.58 0.62 0.67 0.60 0.65 0.59 0.64 0.64 0.69 0.62 0.68 0.62 0.67 0.65 0.71 0.64 0.70 0.64 0.69 0.66 0.72 0.65 0.71 0.65 0.71 0.66 0.72 0.66 0.72 0.66 0.72 0.67 0.73 0.66 0.72 0.66 0.72 0.67 0.73 0.67 0.73 0.66 0.72 0.68 0.74 0.68 0.74 0.67 0.73 0.70 0.76 0.69 0.75 0.69 0.75 0.73 0.79 0.71 0.78 0.71 0.77 1.20 1.26 1.12 1.18 1.08 1.14 1.35 1.42 1.26 1.32 1.22 1.28 1.51 1.59 1.41 1.48 1.36 1.43 1.69 1.78 1.57 1.65 1.52 1.60 1.88 1.98 1.76 1.85 1.69 1.78 2.11 2.22 1.97 2.07 1.90 2.00 2.2 2.35 2.09 2.20 2.02 2.12 2.36 2.48 2.21 2.32 2.13 2.24 2.64 2.78 2.47 2.60 2.40 2.52 2.98 3.13 2.79 2.93 2.69 2.83 3.37 3.54 3.15 3.31 3.04 3.20 44.6 47.0 41.1 43.3 39.1 41.2 48.0 50.5 46.3 48.7 45.1 47.5 49.1 51.6 48.6 51.2 48.1 50.6 48.6 51.2 49.0 51.6 49.1 51.6 47.3 49.8 48.3 50.8 48.6 51.2 45.6 48.0 46.7 49.2 47.3 49.7 44.6 47.0 45.8 48.2 46.3 48.8 43.7 46.0 44.8 47.2 45.4 47.8 41.9 44.2 42.9 45.2 43.4 45.7 40.7 42.9 41.3 43.5 41.7 43.9 40.5 42.6 40.5 42.6 40.6 42.7 32.9 33.8 32.4 33.3 31.8 32.7 31.3 32.2 32.6 33.5 32.7 33.7 28.3 29.1 30.3 31.1 31.1 32.0 24.7 25.4 27.1 27.9 28.1 28.9 21.2 21.8 23.4 24.0 24.6 25.3 17.7 18.2 19.8 20.3 20.9 21.5 16.2 16.7 18.1 18.6 19.2 19.7 14.7 15.1 16.5 16.9 17.4 17.9 12.1 12.5 13.6 14.0 14.3 14.7 10.0 10.3 11.1 11.4 11.8 12.1 8.4 8.6 9.2 9.5 9.7 9.9 1.7 1.8 1.8 1.9 1.8 1.9 1.8 1.9 1.7 1.8 1.7 1.8 2.2 2.3 1.9 2.0 1.9 2.0 2.7 2.8 2.4 2.5 2.2 2.3 3.3 3.5 2.9 3.1 2.7 2.8 4.2 4.4 3.6 3.8 3.4 3.6 4.7 4.9 4.1 4.3 3.8 4.1 5.1 5.4 4.6 4.8 4.3 4.5 6.3 6.6 5.6 5.9 5.3 5.6 7.7 8.1 6.9 7.3 6.6 6.9 9.3 9.8 8.4 8.8 8.0 8.4 Airflow CFM 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 1000 1400 HC kW HE LAT COP HWC 24.5 25.6 27.0 28.3 28.1 29.4 28.7 30.0 31.1 32.5 32.5 34.0 33.3 34.8 35.4 37.0 37.1 38.8 38.1 39.8 39.8 41.6 41.9 43.8 43.0 45.0 44.4 46.4 46.8 48.9 48.1 50.3 49.0 51.3 51.8 54.1 53.3 55.7 51.4 53.7 54.3 56.7 55.9 58.4 53.8 56.2 56.8 59.4 58.5 61.1 2.59 2.30 2.57 2.29 2.56 2.28 2.56 2.28 2.56 2.28 2.56 2.28 2.56 2.28 2.57 2.29 2.59 2.30 2.60 2.31 2.61 2.32 2.63 2.34 2.65 2.36 2.68 2.38 2.72 2.42 2.74 2.44 2.77 2.46 2.83 2.52 2.88 2.56 2.83 2.5 2.9 2.6 3.0 2.6 2.90 2.58 2.99 2.66 3.06 2.72 16.7 17.7 19.3 20.5 20.4 21.6 21.0 22.3 23.3 24.8 24.7 26.2 25.5 27.0 27.5 29.2 29.2 31.0 30.1 31.9 31.7 33.7 33.7 35.8 34.8 36.9 36.1 38.3 38.3 40.6 39.5 41.9 40.4 42.8 42.8 45.5 44.2 46.9 42.5 45.1 45.1 47.9 46.5 49.4 44.6 47.4 47.4 50.3 48.8 51.8 92.6 86.9 95.0 88.7 96.1 89.4 96.6 89.9 98.8 91.5 100.1 92.5 100.8 93.0 102.8 94.5 104.4 95.7 105.3 96.3 106.9 97.5 108.8 98.9 109.8 99.7 111.1 100.7 113.3 102.3 114.5 103.2 115.4 103.9 117.9 105.8 119.3 106.8 117.6 105.5 120.3 107.5 121.7 108.6 119.8 107.2 122.6 109.3 124.1 110.4 2.8 3.3 3.1 3.6 3.2 3.8 3.3 3.9 3.6 4.2 3.7 4.4 3.8 4.5 4.0 4.7 4.2 4.9 4.3 5.0 4.5 5.3 4.7 5.5 4.8 5.6 4.9 5.7 5.0 5.9 5.1 6.0 5.2 6.1 5.4 6.3 5.4 6.4 5.3 6.2 5.5 6.4 5.5 6.5 5.4 6.4 5.6 6.5 5.6 6.6 3.7 3.3 3.9 3.5 4.0 3.6 4.0 3.6 4.3 3.8 4.3 3.8 4.4 3.9 4.6 4.1 4.7 4.2 4.7 4.2 4.9 4.4 5.2 4.6 5.3 4.7 5.4 4.8 5.6 5.0 5.7 5.1 6.0 5.3 6.2 5.5 6.4 5.7 6.2 5.6 6.5 5.8 6.7 6.0 6.5 5.8 6.9 6.1 7.1 6.3 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 22 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TS H/V/D 048 (PSC Blower) 1,600 CFM Nominal (Rated) Airflow Cooling, 1,600 CFM Nominal (Rated) Airflow Heating WPD EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 GPM 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 PSI FT Airflow CFM 4.2 4.2 1.1 1.1 2.3 2.3 3.8 3.8 0.9 0.9 2.1 2.1 3.5 3.5 0.8 0.8 1.9 1.9 3.3 3.3 0.8 0.8 1.8 1.8 3.1 3.1 0.8 0.8 1.8 1.8 3.1 3.1 0.8 0.8 1.7 1.7 3.0 3.0 0.8 0.8 1.7 1.7 3.0 3.0 0.8 0.8 1.7 1.7 3.0 3.0 0.8 0.8 1.7 1.7 3.0 3.0 0.7 0.7 1.7 1.7 2.9 2.9 0.7 0.7 1.6 1.6 2.8 2.8 9.6 9.6 2.6 2.6 5.3 5.3 8.7 8.7 2.1 2.1 4.8 4.8 8.0 8.0 1.9 1.9 4.4 4.4 7.6 7.6 1.8 1.8 4.2 4.2 7.3 7.3 1.7 1.7 4.1 4.1 7.1 7.1 1.7 1.7 4.0 4.0 7.0 7.0 1.7 1.7 4.0 4.0 6.9 6.9 1.8 1.8 4.0 4.0 6.9 6.9 1.8 1.8 4.0 4.0 6.8 6.8 1.7 1.7 3.9 3.9 6.7 6.7 1.5 1.5 3.7 3.7 6.5 6.5 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 TC Cooling - EAT 80/67°F Sens/ SC Tot kW HR Ratio Performance capacities shown in thousands of Btuh Heating - EAT 70°F EER HWC Operation not recommended 47.8 51.7 44.4 48.0 42.4 45.9 50.7 54.8 49.1 53.1 47.9 51.8 51.3 55.4 51.0 55.2 50.6 54.7 50.3 54.4 51.1 55.3 51.3 55.4 48.4 52.3 49.8 53.9 50.4 54.5 45.7 49.4 47.6 51.5 48.5 52.4 44.2 47.8 46.2 49.9 47.1 51.0 42.7 46.2 44.8 48.4 45.8 49.5 39.6 42.8 41.6 45.0 42.7 46.1 36.6 39.5 38.4 41.5 39.4 42.6 33.9 36.6 35.4 38.3 36.3 39.3 26.4 31.0 23.5 27.7 22.0 25.9 29.3 34.5 27.6 32.4 26.5 31.1 30.6 36.0 29.8 35.1 29.2 34.4 30.8 36.3 30.8 36.2 30.6 36.0 30.2 35.6 30.7 36.1 30.8 36.3 29.2 34.3 29.9 35.2 30.3 35.6 28.5 33.5 29.3 34.5 29.7 35.0 27.8 32.7 28.7 33.8 29.2 34.3 26.3 31.0 27.3 32.1 27.8 32.7 25.0 29.4 25.8 30.4 26.3 30.9 24.0 28.2 24.5 28.9 24.9 29.3 0.55 0.60 0.53 0.58 0.52 0.56 0.58 0.63 0.56 0.61 0.55 0.60 0.60 0.65 0.58 0.64 0.58 0.63 0.61 0.67 0.60 0.66 0.60 0.65 0.63 0.68 0.62 0.67 0.61 0.67 0.64 0.69 0.63 0.68 0.62 0.68 0.64 0.70 0.64 0.69 0.63 0.69 0.65 0.71 0.64 0.70 0.64 0.69 0.67 0.72 0.66 0.71 0.65 0.71 0.68 0.74 0.67 0.73 0.67 0.72 0.71 0.77 0.69 0.75 0.69 0.75 2.01 2.11 1.85 1.95 1.79 1.88 2.23 2.35 2.08 2.19 2.01 2.11 2.46 2.59 2.30 2.42 2.23 2.34 2.71 2.85 2.54 2.67 2.45 2.58 2.98 3.13 2.79 2.93 2.69 2.83 3.27 3.44 3.06 3.22 2.97 3.12 3.4 3.62 3.22 3.39 3.11 3.28 3.60 3.79 3.38 3.55 3.26 3.43 3.98 4.18 3.73 3.92 3.60 3.79 4.40 4.63 4.13 4.34 3.99 4.20 4.90 5.15 4.58 4.82 4.44 4.67 56.0 58.9 52.0 54.7 49.7 52.3 59.7 62.8 57.5 60.5 56.0 59.0 61.1 64.3 60.3 63.5 59.6 62.7 60.9 64.1 61.1 64.4 61.0 64.2 59.8 63.0 60.7 63.9 61.0 64.2 58.1 61.2 59.4 62.5 59.9 63.0 57.1 60.2 58.4 61.5 59.0 62.1 56.2 59.1 57.5 60.5 58.2 61.2 54.2 57.1 55.5 58.4 56.1 59.1 52.5 55.3 53.5 56.3 54.1 57.0 51.5 54.2 52.0 54.8 52.4 55.2 23.8 24.5 24.0 24.6 23.7 24.4 22.7 23.3 23.6 24.2 23.9 24.5 20.8 21.4 22.2 22.8 22.7 23.4 18.6 19.1 20.1 20.7 20.9 21.5 16.2 16.7 17.9 18.4 18.7 19.3 14.0 14.4 15.5 16.0 16.3 16.8 12.9 13.3 14.4 14.8 15.2 15.6 11.9 12.2 13.3 13.6 14.0 14.4 10.0 10.2 11.2 11.5 11.8 12.2 8.3 8.5 9.3 9.6 9.9 10.1 6.9 7.1 7.7 8.0 8.2 8.4 1.7 1.8 1.8 1.9 1.8 1.9 1.9 2.0 1.7 1.8 1.7 1.8 2.3 2.4 2.0 2.1 1.9 2.0 2.8 2.9 2.4 2.5 2.2 2.3 3.5 3.7 2.9 3.1 2.8 2.9 4.4 4.6 3.7 3.9 3.4 3.6 4.9 5.2 4.2 4.4 3.9 4.1 5.4 5.7 4.7 4.9 4.4 4.6 6.6 6.9 5.8 6.1 5.4 5.7 8.0 8.4 7.1 7.5 6.7 7.0 9.5 10.0 8.6 9.0 8.1 8.5 Airflow CFM 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 1150 1600 HC kW HE LAT COP HWC 34.6 36.1 37.3 39.0 38.9 40.7 39.8 41.6 42.3 44.2 44.3 46.3 45.4 47.5 47.6 49.7 50.0 52.2 51.3 53.6 52.9 55.3 55.7 58.2 57.2 59.8 58.4 61.0 61.5 64.2 63.2 66.0 63.8 66.6 67.1 70.1 68.9 72.0 66.4 69.4 69.8 73.0 71.7 74.9 69.0 72.1 72.6 75.8 74.4 77.8 3.78 3.36 3.78 3.36 3.79 3.37 3.80 3.38 3.82 3.40 3.84 3.42 3.86 3.43 3.89 3.46 3.93 3.50 3.96 3.52 3.99 3.55 4.05 3.60 4.08 3.63 4.11 3.66 4.18 3.72 4.23 3.76 4.24 3.77 4.33 3.85 4.37 3.89 4.30 3.8 4.4 3.9 4.4 4.0 4.37 3.89 4.46 3.97 4.51 4.01 23.2 24.6 26.0 27.6 27.5 29.2 28.3 30.1 30.8 32.7 32.6 34.7 33.7 35.8 35.7 37.9 37.9 40.3 39.2 41.6 40.7 43.2 43.3 45.9 44.7 47.4 45.7 48.5 48.5 51.5 50.1 53.2 50.6 53.8 53.7 57.0 55.4 58.8 53.0 56.3 56.2 59.6 57.9 61.4 55.5 58.9 58.7 62.3 60.4 64.1 97.8 90.9 100.1 92.6 101.3 93.5 102.1 94.1 104.1 95.6 105.7 96.8 106.6 97.5 108.3 98.8 110.2 100.2 111.3 101.0 112.6 102.0 114.9 103.7 116.1 104.6 117.0 105.3 119.5 107.2 120.9 108.2 121.3 108.6 124.0 110.6 125.5 111.7 123.5 110.2 126.2 112.2 127.7 113.3 125.6 111.7 128.4 113.9 129.9 115.0 2.7 3.2 2.9 3.4 3.0 3.5 3.1 3.6 3.2 3.8 3.4 4.0 3.5 4.1 3.6 4.2 3.7 4.4 3.8 4.5 3.9 4.6 4.0 4.7 4.1 4.8 4.2 4.9 4.3 5.1 4.4 5.1 4.4 5.2 4.5 5.3 4.6 5.4 4.5 5.3 4.7 5.5 4.7 5.6 4.6 5.4 4.8 5.6 4.8 5.7 3.7 3.3 3.9 3.5 3.9 3.5 4.0 3.6 4.2 3.7 4.3 3.8 4.4 3.9 4.5 4.0 4.6 4.1 4.7 4.2 4.8 4.3 5.1 4.5 5.2 4.6 5.3 4.7 5.6 5.0 5.7 5.1 5.8 5.2 6.2 5.5 6.3 5.6 6.1 5.5 6.5 5.8 6.6 5.9 6.4 5.7 6.7 6.0 7.0 6.2 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 23 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TS H/V/D 048 (ECM Blower) 1,550 CFM Nominal (Rated) Airflow Cooling, 1,650 CFM Nominal (Rated) Airflow Heating WPD EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 GPM 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 PSI FT Airflow CFM 4.2 4.2 1.1 1.1 2.3 2.3 3.8 3.8 0.9 0.9 2.1 2.1 3.5 3.5 0.8 0.8 1.9 1.9 3.3 3.3 0.8 0.8 1.8 1.8 3.1 3.1 0.8 0.8 1.8 1.8 3.1 3.1 0.8 0.8 1.7 1.7 3.0 3.0 0.8 0.8 1.7 1.7 3.0 3.0 0.8 0.8 1.7 1.7 3.0 3.0 0.8 0.8 1.7 1.7 3.0 3.0 0.7 0.7 1.7 1.7 2.9 2.9 0.7 0.7 1.6 1.6 2.8 2.8 9.6 9.6 2.6 2.6 5.3 5.3 8.7 8.7 2.1 2.1 4.8 4.8 8.0 8.0 1.9 1.9 4.4 4.4 7.6 7.6 1.8 1.8 4.2 4.2 7.3 7.3 1.7 1.7 4.1 4.1 7.1 7.1 1.7 1.7 4.0 4.0 7.0 7.0 1.7 1.7 4.0 4.0 6.9 6.9 1.8 1.8 4.0 4.0 6.9 6.9 1.8 1.8 4.0 4.0 6.8 6.8 1.7 1.7 3.9 3.9 6.7 6.7 1.5 1.5 3.7 3.7 6.5 6.5 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 1100 1550 TC Cooling - EAT 80/67°F Sens/ SC Tot kW HR Ratio Performance capacities shown in thousands of Btuh Heating - EAT 70°F EER HWC Operation not recommended 47.7 51.5 44.3 47.9 42.3 45.7 50.6 54.7 49.0 53.0 47.8 51.7 51.3 55.4 51.0 55.2 50.6 54.7 50.4 54.5 51.1 55.3 51.3 55.4 48.4 52.4 49.9 53.9 50.4 54.5 45.8 49.6 47.7 51.5 48.5 52.5 44.3 47.9 46.3 50.0 47.2 51.0 42.8 46.3 44.9 48.5 45.8 49.6 39.7 42.9 41.7 45.1 42.7 46.2 36.6 39.6 38.5 41.6 39.5 42.7 34.0 36.7 35.5 38.4 36.4 39.3 26.3 30.9 23.4 27.6 21.9 25.8 29.2 34.4 27.5 32.3 26.4 31.0 30.6 36.0 29.8 35.1 29.2 34.3 30.8 36.3 30.8 36.2 30.6 36.0 30.3 35.6 30.7 36.1 30.8 36.3 29.2 34.3 30.0 35.3 30.3 35.6 28.5 33.5 29.4 34.5 29.7 35.0 27.8 32.8 28.8 33.8 29.2 34.4 26.4 31.0 27.3 32.1 27.8 32.7 25.0 29.4 25.8 30.4 26.3 30.9 24.0 28.2 24.6 28.9 24.9 29.3 0.55 0.60 0.53 0.58 0.52 0.56 0.58 0.63 0.56 0.61 0.55 0.60 0.60 0.65 0.58 0.64 0.58 0.63 0.61 0.67 0.60 0.65 0.60 0.65 0.62 0.68 0.62 0.67 0.61 0.67 0.64 0.69 0.63 0.68 0.62 0.68 0.64 0.70 0.63 0.69 0.63 0.69 0.65 0.71 0.64 0.70 0.64 0.69 0.66 0.72 0.65 0.71 0.65 0.71 0.68 0.74 0.67 0.73 0.67 0.72 0.71 0.77 0.69 0.75 0.69 0.75 1.71 1.80 1.57 1.65 1.50 1.58 1.95 2.05 1.80 1.89 1.72 1.81 2.18 2.29 2.02 2.12 1.94 2.04 2.43 2.55 2.25 2.37 2.17 2.28 2.69 2.83 2.50 2.63 2.41 2.53 2.98 3.13 2.78 2.92 2.68 2.82 3.1 3.31 2.93 3.09 2.83 2.98 3.31 3.48 3.09 3.25 2.98 3.13 3.68 3.87 3.43 3.61 3.32 3.49 4.11 4.32 3.83 4.03 3.71 3.90 4.60 4.84 4.30 4.52 4.15 4.36 54.8 57.7 50.8 53.5 48.6 51.1 58.6 61.7 56.5 59.4 55.0 57.9 60.1 63.2 59.3 62.4 58.6 61.6 60.0 63.2 60.2 63.4 60.0 63.2 58.9 62.0 59.8 62.9 60.0 63.2 57.2 60.2 58.4 61.5 59.0 62.1 56.3 59.2 57.5 60.5 58.1 61.2 55.3 58.2 56.6 59.6 57.2 60.3 53.3 56.1 54.5 57.4 55.2 58.1 51.6 54.4 52.6 55.4 53.2 56.0 50.6 53.2 51.1 53.8 51.5 54.2 27.9 28.6 28.2 29.0 28.2 28.9 26.0 26.7 27.3 28.0 27.8 28.6 23.5 24.2 25.3 26.0 26.1 26.8 20.8 21.4 22.7 23.3 23.6 24.3 18.0 18.5 19.9 20.5 21.0 21.6 15.4 15.8 17.2 17.7 18.1 18.6 14.2 14.6 15.8 16.3 16.7 17.2 12.9 13.3 14.5 14.9 15.4 15.8 10.8 11.1 12.1 12.5 12.9 13.2 8.9 9.2 10.0 10.3 10.6 10.9 7.4 7.6 8.3 8.5 8.8 9.0 1.7 1.8 1.8 1.9 1.8 1.9 1.9 2.0 1.7 1.8 1.7 1.8 2.3 2.4 2.0 2.1 1.9 2.0 2.8 2.9 2.4 2.5 2.2 2.3 3.5 3.7 2.9 3.1 2.8 2.9 4.4 4.6 3.7 3.9 3.4 3.6 4.9 5.2 4.2 4.4 3.9 4.1 5.4 5.7 4.7 4.9 4.4 4.6 6.6 6.9 5.8 6.1 5.4 5.7 8.0 8.4 7.1 7.5 6.7 7.0 9.5 10.0 8.6 9.0 8.1 8.5 Airflow CFM 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 1200 1650 HC kW HE LAT COP HWC 31.7 33.1 34.4 36.0 35.8 37.4 36.6 38.2 39.1 40.9 40.8 42.7 41.8 43.7 44.1 46.0 46.2 48.2 47.3 49.4 49.2 51.4 51.6 53.9 52.9 55.3 54.3 56.8 57.1 59.7 58.6 61.2 59.5 62.2 62.5 65.3 64.1 67.0 62.0 64.8 65.1 68.0 66.7 69.7 64.5 67.4 67.7 70.7 69.3 72.5 3.45 3.07 3.45 3.07 3.46 3.08 3.46 3.08 3.50 3.11 3.52 3.13 3.53 3.14 3.56 3.17 3.61 3.21 3.63 3.23 3.68 3.27 3.73 3.32 3.77 3.35 3.80 3.38 3.87 3.44 3.90 3.47 3.92 3.49 4.00 3.56 4.05 3.60 3.99 3.6 4.1 3.6 4.1 3.7 4.06 3.61 4.15 3.69 4.18 3.72 21.3 22.7 24.0 25.5 25.4 26.9 26.1 27.7 28.5 30.3 30.2 32.0 31.1 33.0 33.2 35.2 35.1 37.3 36.2 38.4 37.9 40.2 40.1 42.6 41.4 43.9 42.6 45.3 45.1 47.9 46.5 49.4 47.3 50.2 50.1 53.1 51.5 54.7 49.6 52.7 52.4 55.6 53.9 57.2 51.9 55.1 54.8 58.2 56.3 59.8 94.5 88.6 96.6 90.2 97.6 91.0 98.2 91.4 100.2 92.9 101.5 94.0 102.3 94.5 104.0 95.8 105.6 97.1 106.5 97.7 107.9 98.8 109.8 100.3 110.9 101.0 111.9 101.9 114.1 103.5 115.2 104.4 115.9 104.9 118.2 106.6 119.5 107.6 117.9 106.4 120.2 108.2 121.5 109.1 119.8 107.8 122.2 109.7 123.5 110.7 2.7 3.2 2.9 3.4 3.0 3.6 3.1 3.6 3.3 3.9 3.4 4.0 3.5 4.1 3.6 4.3 3.7 4.4 3.8 4.5 3.9 4.6 4.1 4.8 4.1 4.8 4.2 4.9 4.3 5.1 4.4 5.2 4.4 5.2 4.6 5.4 4.6 5.5 4.6 5.3 4.7 5.5 4.8 5.6 4.7 5.5 4.8 5.6 4.9 5.7 3.7 3.3 3.9 3.5 3.9 3.5 4.0 3.6 4.2 3.7 4.3 3.8 4.4 3.9 4.5 4.0 4.6 4.1 4.7 4.2 4.8 4.3 5.1 4.5 5.2 4.6 5.3 4.7 5.6 5.0 5.7 5.1 5.8 5.2 6.2 5.5 6.3 5.6 6.1 5.5 6.5 5.8 6.6 5.9 6.4 5.7 6.7 6.0 7.0 6.2 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 24 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TS H/V/D 060 (PSC Blower) 1,950 CFM Nominal (Rated) Airflow Cooling, 1,950 CFM Nominal (Rated) Airflow Heating WPD EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 GPM 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 PSI FT Airflow CFM 7.2 7.2 1.3 1.3 3.5 3.5 6.1 6.1 0.9 0.9 2.9 2.9 5.3 5.3 0.6 0.6 2.5 2.5 4.7 4.7 0.5 0.5 2.2 2.2 4.3 4.3 0.5 0.5 2.1 2.1 4.1 4.1 0.5 0.5 2.0 2.0 4.0 4.0 0.5 0.5 2.0 2.0 4.0 4.0 0.5 0.5 2.0 2.0 3.9 3.9 0.5 0.5 1.9 1.9 3.9 3.9 0.4 0.4 1.8 1.8 3.8 3.8 0.1 0.1 1.6 1.6 3.7 3.7 16.6 16.6 3.0 3.0 8.1 8.1 14.1 14.1 2.0 2.0 6.7 6.7 12.2 12.2 1.4 1.4 5.7 5.7 10.9 10.9 1.1 1.1 5.1 5.1 10.0 10.0 1.1 1.1 4.8 4.8 9.5 9.5 1.1 1.1 4.6 4.6 9.2 9.2 1.1 1.1 4.6 4.6 9.1 9.1 1.2 1.2 4.5 4.5 9.1 9.1 1.1 1.1 4.5 4.5 9.0 9.0 0.8 0.8 4.2 4.2 8.8 8.8 0.3 0.3 3.8 3.8 8.5 8.5 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 TC Cooling - EAT 80/67°F Sens/ SC Tot kW HR Ratio Performance capacities shown in thousands of Btuh Heating - EAT 70°F EER HWC Operation not recommended 68.4 74.0 66.0 71.4 64.2 69.5 69.5 75.1 68.9 74.5 68.2 73.7 68.6 74.1 69.4 75.0 69.5 75.1 66.3 71.7 68.1 73.6 68.8 74.3 63.2 68.3 65.5 70.9 66.6 72.0 59.5 64.4 62.2 67.2 63.5 68.6 57.6 62.3 60.3 65.1 61.6 66.6 55.7 60.2 58.3 63.1 59.7 64.5 51.9 56.1 54.4 58.8 55.7 60.2 48.6 52.5 50.7 54.8 51.8 56.1 46.1 49.8 47.6 51.4 48.5 52.4 43.6 51.3 41.7 49.0 40.4 47.6 44.8 52.8 44.0 51.8 43.4 51.0 45.0 52.9 45.0 52.9 44.8 52.7 44.3 52.2 44.9 52.8 45.0 53.0 43.2 50.8 44.1 51.9 44.4 52.3 41.8 49.1 42.8 50.4 43.3 51.0 41.0 48.2 42.0 49.5 42.6 50.1 40.2 47.3 41.3 48.6 41.8 49.2 38.7 45.5 39.7 46.7 40.2 47.3 37.6 44.2 38.3 45.0 38.7 45.5 37.2 43.7 37.3 43.9 37.6 44.2 0.64 0.69 0.63 0.69 0.63 0.69 0.65 0.70 0.64 0.70 0.64 0.69 0.66 0.71 0.65 0.71 0.64 0.70 0.67 0.73 0.66 0.72 0.65 0.71 0.68 0.74 0.67 0.73 0.67 0.73 0.70 0.76 0.69 0.75 0.68 0.74 0.71 0.77 0.70 0.76 0.69 0.75 0.72 0.79 0.71 0.77 0.70 0.76 0.75 0.81 0.73 0.79 0.72 0.79 0.77 0.84 0.76 0.82 0.75 0.81 0.81 0.88 0.78 0.85 0.77 0.84 2.41 2.53 2.26 2.38 2.20 2.31 2.63 2.77 2.46 2.59 2.39 2.51 2.89 3.04 2.69 2.83 2.61 2.74 3.18 3.34 2.96 3.11 2.85 3.00 3.52 3.70 3.26 3.43 3.15 3.31 3.90 4.10 3.62 3.81 3.49 3.67 4.1 4.33 3.83 4.03 3.69 3.88 4.34 4.56 4.03 4.24 3.88 4.08 4.85 5.10 4.51 4.74 4.34 4.56 5.45 5.73 5.05 5.31 4.86 5.11 6.15 6.47 5.69 5.98 5.48 5.76 78.5 82.6 75.5 79.5 73.5 77.4 80.3 84.6 79.2 83.4 78.2 82.3 80.3 84.5 80.5 84.7 80.2 84.4 78.9 83.1 80.0 84.2 80.3 84.6 76.9 80.9 78.4 82.6 79.1 83.3 74.4 78.3 76.2 80.2 77.1 81.1 73.2 77.1 74.9 78.9 75.8 79.8 72.0 75.8 73.7 77.5 74.5 78.5 69.9 73.5 71.2 75.0 72.0 75.8 68.5 72.1 69.3 72.9 69.8 73.5 68.3 71.9 68.2 71.8 68.4 72.0 28.4 29.2 29.2 30.0 29.2 30.1 26.4 27.1 28.0 28.8 28.6 29.4 23.7 24.4 25.8 26.5 26.7 27.4 20.9 21.5 23.0 23.7 24.1 24.8 18.0 18.5 20.1 20.7 21.2 21.8 15.3 15.7 17.2 17.6 18.2 18.7 14.1 14.4 15.8 16.3 16.8 17.3 12.8 13.2 14.5 14.9 15.4 15.8 10.7 11.0 12.1 12.4 12.8 13.2 8.9 9.2 10.0 10.3 10.7 11.0 7.5 7.7 8.4 8.6 8.8 9.1 1.9 2.0 1.7 1.8 1.7 1.8 2.2 2.3 1.9 2.0 1.8 1.9 2.8 2.9 2.3 2.4 2.2 2.3 3.4 3.6 2.9 3.1 2.7 2.8 4.3 4.5 3.6 3.8 3.3 3.5 5.3 5.6 4.6 4.8 4.2 4.4 5.9 6.2 5.1 5.4 4.7 5.0 6.5 6.8 5.7 6.0 5.2 5.5 7.9 8.3 6.9 7.3 6.5 6.8 9.4 9.9 8.4 8.8 7.9 8.3 11.3 11.9 10.1 10.6 9.5 10.0 Airflow CFM 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 HC kW HE LAT COP HWC 39.4 41.2 43.0 44.9 44.8 46.8 45.8 47.8 49.3 51.5 51.7 54.0 53.0 55.4 56.2 58.7 59.1 61.8 60.8 63.5 63.3 66.2 66.9 69.9 68.8 71.9 70.7 73.8 74.7 78.1 76.9 80.4 78.0 81.5 82.4 86.1 84.8 88.7 81.5 85.2 86.1 90.0 88.6 92.5 85.1 88.9 89.8 93.8 92.3 96.4 4.45 3.96 4.55 4.05 4.60 4.09 4.62 4.11 4.71 4.19 4.75 4.23 4.79 4.26 4.84 4.31 4.91 4.37 4.93 4.39 4.99 4.44 5.06 4.50 5.10 4.54 5.14 4.57 5.23 4.65 5.27 4.69 5.31 4.72 5.41 4.81 5.47 4.87 5.40 4.8 5.5 4.9 5.6 5.0 5.49 4.88 5.62 5.00 5.71 5.08 26.1 27.7 29.3 31.1 30.9 32.8 31.8 33.8 35.1 37.3 37.3 39.6 38.5 40.9 41.4 44.0 44.2 46.9 45.7 48.5 48.1 51.0 51.4 54.5 53.2 56.4 54.9 58.2 58.6 62.2 60.7 64.4 61.6 65.4 65.7 69.7 67.9 72.0 64.9 68.8 69.0 73.2 71.2 75.6 68.1 72.3 72.3 76.8 74.5 79.1 96.1 89.6 98.4 91.3 99.6 92.2 100.3 92.7 102.6 94.5 104.2 95.6 105.0 96.3 107.1 97.9 109.1 99.3 110.2 100.2 111.9 101.4 114.2 103.2 115.5 104.2 116.7 105.1 119.4 107.1 120.9 108.2 121.6 108.7 124.5 110.9 126.1 112.1 123.9 110.5 127.0 112.7 128.6 113.9 126.3 112.2 129.4 114.6 131.0 115.8 2.6 3.0 2.8 3.3 2.9 3.4 2.9 3.4 3.1 3.6 3.2 3.7 3.2 3.8 3.4 4.0 3.5 4.1 3.6 4.2 3.7 4.4 3.9 4.6 4.0 4.6 4.0 4.7 4.2 4.9 4.3 5.0 4.3 5.1 4.5 5.2 4.5 5.3 4.4 5.2 4.6 5.4 4.6 5.5 4.5 5.3 4.7 5.5 4.7 5.6 4.3 3.8 4.5 4.0 4.6 4.1 4.6 4.1 4.8 4.3 4.9 4.4 5.1 4.5 5.2 4.6 5.4 4.8 5.5 4.9 5.6 5.0 5.8 5.2 6.0 5.3 6.1 5.4 6.4 5.7 6.6 5.9 6.6 5.9 7.1 6.3 7.3 6.5 7.0 6.2 7.4 6.6 7.6 6.8 7.3 6.5 7.8 6.9 8.0 7.1 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 25 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TS H/V/D 060 (ECM Blower) 1,950 CFM Nominal (Rated) Airflow Cooling, 2,050 CFM Nominal (Rated) Airflow Heating WPD EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 GPM 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 PSI FT Airflow CFM 7.2 7.2 1.3 1.3 3.5 3.5 6.1 6.1 0.9 0.9 2.9 2.9 5.3 5.3 0.6 0.6 2.5 2.5 4.7 4.7 0.5 0.5 2.2 2.2 4.3 4.3 0.5 0.5 2.1 2.1 4.1 4.1 0.5 0.5 2.0 2.0 4.0 4.0 0.5 0.5 2.0 2.0 4.0 4.0 0.5 0.5 2.0 2.0 3.9 3.9 0.5 0.5 1.9 1.9 3.9 3.9 0.4 0.4 1.8 1.8 3.8 3.8 0.1 0.1 1.6 1.6 3.7 3.7 16.6 16.6 3.0 3.0 8.1 8.1 14.1 14.1 2.0 2.0 6.7 6.7 12.2 12.2 1.4 1.4 5.7 5.7 10.9 10.9 1.1 1.1 5.1 5.1 10.0 10.0 1.1 1.1 4.8 4.8 9.5 9.5 1.1 1.1 4.6 4.6 9.2 9.2 1.1 1.1 4.6 4.6 9.1 9.1 1.2 1.2 4.5 4.5 9.1 9.1 1.1 1.1 4.5 4.5 9.0 9.0 0.8 0.8 4.2 4.2 8.8 8.8 0.3 0.3 3.8 3.8 8.5 8.5 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 TC Cooling - EAT 80/67°F Sens/ SC Tot kW HR Ratio Performance capacities shown in thousands of Btuh Heating - EAT 70°F EER HWC Operation not recommended 68.4 74.0 66.0 71.4 64.2 69.5 69.5 75.1 68.9 74.5 68.2 73.7 68.6 74.1 69.4 75.0 69.5 75.1 66.3 71.7 68.1 73.6 68.8 74.3 63.2 68.3 65.5 70.9 66.6 72.0 59.5 64.4 62.2 67.2 63.5 68.6 57.6 62.3 60.3 65.1 61.6 66.6 55.7 60.2 58.3 63.1 59.7 64.5 51.9 56.1 54.4 58.8 55.7 60.2 48.6 52.5 50.7 54.8 51.8 56.1 46.1 49.8 47.6 51.4 48.5 52.4 43.6 51.3 41.7 49.0 40.4 47.6 44.8 52.8 44.0 51.8 43.4 51.0 45.0 52.9 45.0 52.9 44.8 52.7 44.3 52.2 44.9 52.8 45.0 53.0 43.2 50.8 44.1 51.9 44.4 52.3 41.8 49.1 42.8 50.4 43.3 51.0 41.0 48.2 42.0 49.5 42.6 50.1 40.2 47.3 41.3 48.6 41.8 49.2 38.7 45.5 39.7 46.7 40.2 47.3 37.6 44.2 38.3 45.0 38.7 45.5 37.2 43.7 37.3 43.9 37.6 44.2 0.64 0.69 0.63 0.69 0.63 0.69 0.65 0.70 0.64 0.70 0.64 0.69 0.66 0.71 0.65 0.71 0.64 0.70 0.67 0.73 0.66 0.72 0.65 0.71 0.68 0.74 0.67 0.73 0.67 0.73 0.70 0.76 0.69 0.75 0.68 0.74 0.71 0.77 0.70 0.76 0.69 0.75 0.72 0.79 0.71 0.77 0.70 0.76 0.75 0.81 0.73 0.79 0.72 0.79 0.77 0.84 0.76 0.82 0.75 0.81 0.81 0.88 0.78 0.85 0.77 0.84 2.41 2.53 2.26 2.38 2.20 2.31 2.63 2.77 2.46 2.59 2.39 2.51 2.89 3.04 2.69 2.83 2.61 2.74 3.18 3.34 2.96 3.11 2.85 3.00 3.52 3.70 3.26 3.43 3.15 3.31 3.90 4.10 3.62 3.81 3.49 3.67 4.1 4.33 3.83 4.03 3.69 3.88 4.34 4.56 4.03 4.24 3.88 4.08 4.85 5.10 4.51 4.74 4.34 4.56 5.45 5.73 5.05 5.31 4.86 5.11 6.15 6.47 5.69 5.98 5.48 5.76 78.5 82.6 75.5 79.5 73.5 77.4 80.3 84.6 79.2 83.4 78.2 82.3 80.3 84.5 80.5 84.7 80.2 84.4 78.9 83.1 80.0 84.2 80.3 84.6 76.9 80.9 78.4 82.6 79.1 83.3 74.4 78.3 76.2 80.2 77.1 81.1 73.2 77.1 74.9 78.9 75.8 79.8 72.0 75.8 73.7 77.5 74.5 78.5 69.9 73.5 71.2 75.0 72.0 75.8 68.5 72.1 69.3 72.9 69.8 73.5 68.3 71.9 68.2 71.8 68.4 72.0 28.4 29.2 29.2 30.0 29.2 30.1 26.4 27.1 28.0 28.8 28.6 29.4 23.7 24.4 25.8 26.5 26.7 27.4 20.9 21.5 23.0 23.7 24.1 24.8 18.0 18.5 20.1 20.7 21.2 21.8 15.3 15.7 17.2 17.6 18.2 18.7 14.1 14.4 15.8 16.3 16.8 17.3 12.8 13.2 14.5 14.9 15.4 15.8 10.7 11.0 12.1 12.4 12.8 13.2 8.9 9.2 10.0 10.3 10.7 11.0 7.5 7.7 8.4 8.6 8.8 9.1 1.9 2.0 1.7 1.8 1.7 1.8 2.2 2.3 1.9 2.0 1.8 1.9 2.8 2.9 2.3 2.4 2.2 2.3 3.4 3.6 2.9 3.1 2.7 2.8 4.3 4.5 3.6 3.8 3.3 3.5 5.3 5.6 4.6 4.8 4.2 4.4 5.9 6.2 5.1 5.4 4.7 5.0 6.5 6.8 5.7 6.0 5.2 5.5 7.9 8.3 6.9 7.3 6.5 6.8 9.4 9.9 8.4 8.8 7.9 8.3 11.3 11.9 10.1 10.6 9.5 10.0 Airflow CFM 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 HC kW HE LAT COP HWC 38.5 40.2 42.0 43.9 43.7 45.7 44.7 46.7 48.2 50.4 50.6 52.9 51.9 54.2 55.1 57.5 58.0 60.6 59.7 62.4 62.2 65.0 65.8 68.7 67.8 70.8 69.5 72.7 73.6 76.9 75.8 79.2 76.8 80.2 81.1 84.7 83.4 87.2 80.2 83.8 84.6 88.4 86.9 90.8 83.7 87.4 88.1 92.1 90.4 94.4 4.07 3.62 4.14 3.68 4.17 3.71 4.19 3.73 4.25 3.78 4.29 3.82 4.33 3.85 4.38 3.90 4.44 3.95 4.47 3.98 4.52 4.02 4.60 4.09 4.63 4.12 4.68 4.16 4.77 4.24 4.81 4.28 4.83 4.30 4.95 4.40 5.01 4.46 4.92 4.4 5.0 4.5 5.1 4.6 5.01 4.46 5.15 4.58 5.22 4.64 26.2 27.8 29.5 31.3 31.1 33.0 32.0 34.0 35.3 37.5 37.5 39.8 38.7 41.1 41.7 44.2 44.4 47.2 46.0 48.8 48.3 51.3 51.6 54.8 53.4 56.7 55.1 58.5 58.8 62.4 60.8 64.6 61.7 65.5 65.7 69.7 67.8 72.0 64.9 68.9 68.8 73.1 70.9 75.3 68.0 72.2 72.0 76.4 74.0 78.6 94.2 88.2 96.3 89.8 97.5 90.6 98.1 91.1 100.3 92.8 101.8 93.9 102.6 94.5 104.6 96.0 106.4 97.4 107.5 98.2 109.1 99.4 111.3 101.1 112.5 102.0 113.7 102.8 116.2 104.7 117.6 105.8 118.2 106.2 120.9 108.3 122.4 109.4 120.4 107.9 123.1 109.9 124.5 111.0 122.5 109.5 125.3 111.6 126.7 112.6 2.8 3.3 3.0 3.5 3.1 3.6 3.1 3.7 3.3 3.9 3.5 4.1 3.5 4.1 3.7 4.3 3.8 4.5 3.9 4.6 4.0 4.7 4.2 4.9 4.3 5.0 4.4 5.1 4.5 5.3 4.6 5.4 4.7 5.5 4.8 5.6 4.9 5.7 4.8 5.6 4.9 5.8 5.0 5.8 4.9 5.7 5.0 5.9 5.1 6.0 4.3 3.8 4.5 4.0 4.6 4.1 4.6 4.1 4.8 4.3 4.9 4.4 5.1 4.5 5.2 4.6 5.4 4.8 5.5 4.9 5.6 5.0 5.8 5.2 6.0 5.3 6.1 5.4 6.4 5.7 6.6 5.9 6.6 5.9 7.1 6.3 7.3 6.5 7.0 6.2 7.4 6.6 7.6 6.8 7.3 6.5 7.8 6.9 8.0 7.1 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 26 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TS H/V/D 070 (PSC Blower) 2,100 CFM Nominal (Rated) Airflow Cooling, 2,100 CFM Nominal (Rated) Airflow Heating WPD EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 GPM 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 PSI FT Airflow CFM 9.5 9.5 2.7 2.7 5.2 5.2 8.1 8.1 2.1 2.1 4.4 4.4 7.1 7.1 1.7 1.7 3.8 3.8 6.4 6.4 1.6 1.6 3.5 3.5 5.9 5.9 1.5 1.5 3.3 3.3 5.7 5.7 1.5 1.5 3.2 3.2 5.5 5.5 1.5 1.5 3.2 3.2 5.5 5.5 1.6 1.6 3.2 3.2 5.5 5.5 1.6 1.6 3.2 3.2 5.4 5.4 1.4 1.4 3.1 3.1 5.3 5.3 1.2 1.2 2.9 2.9 5.2 5.2 22.0 22.0 6.3 6.3 12.0 12.0 18.8 18.8 4.9 4.9 10.1 10.1 16.4 16.4 4.0 4.0 8.8 8.8 14.8 14.8 3.6 3.6 8.1 8.1 13.7 13.7 3.5 3.5 7.6 7.6 13.1 13.1 3.5 3.5 7.5 7.5 12.8 12.8 3.6 3.6 7.5 7.5 12.7 12.7 3.6 3.6 7.4 7.4 12.6 12.6 3.6 3.6 7.4 7.4 12.5 12.5 3.3 3.3 7.1 7.1 12.3 12.3 2.7 2.7 6.6 6.6 11.9 11.9 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 TC Cooling - EAT 80/67°F Sens/ SC Tot kW HR Ratio Performance capacities shown in thousands of Btuh Heating - EAT 70°F EER HWC Operation not recommended 76.3 82.5 74.8 80.9 73.7 79.6 76.8 83.0 76.6 82.8 76.2 82.4 75.6 81.7 76.6 82.8 76.8 83.0 73.3 79.2 75.0 81.1 75.7 81.9 70.1 75.8 72.4 78.3 73.4 79.4 66.4 71.7 69.0 74.6 70.2 75.9 64.3 69.5 67.0 72.4 68.3 73.8 62.3 67.3 65.0 70.3 66.4 71.7 58.1 62.8 60.8 65.7 62.2 67.2 54.1 58.5 56.6 61.2 57.9 62.6 50.4 54.5 52.6 56.8 53.8 58.1 43.4 51.0 41.4 48.7 40.2 47.3 45.0 52.9 44.0 51.8 43.3 50.9 45.4 53.4 45.2 53.2 44.9 52.8 45.0 52.9 45.4 53.4 45.4 53.4 43.9 51.7 44.7 52.6 45.0 52.9 42.5 50.0 43.5 51.2 43.9 51.7 41.7 49.0 42.7 50.3 43.2 50.8 40.9 48.1 41.9 49.4 42.5 50.0 39.3 46.2 40.3 47.4 40.8 48.0 37.8 44.5 38.7 45.5 39.2 46.1 36.8 43.3 37.4 44.0 37.7 44.4 0.57 0.62 0.55 0.60 0.55 0.59 0.59 0.64 0.57 0.62 0.57 0.62 0.60 0.65 0.59 0.64 0.59 0.64 0.61 0.67 0.60 0.66 0.60 0.65 0.63 0.68 0.62 0.67 0.61 0.67 0.64 0.70 0.63 0.69 0.63 0.68 0.65 0.71 0.64 0.69 0.63 0.69 0.66 0.71 0.65 0.70 0.64 0.70 0.68 0.74 0.66 0.72 0.66 0.71 0.70 0.76 0.68 0.74 0.68 0.74 0.73 0.79 0.71 0.77 0.70 0.76 3.27 3.44 3.10 3.26 3.02 3.18 3.56 3.74 3.36 3.53 3.26 3.43 3.87 4.07 3.64 3.83 3.54 3.72 4.22 4.44 3.97 4.17 3.85 4.05 4.63 4.87 4.35 4.57 4.20 4.42 5.09 5.35 4.77 5.02 4.62 4.86 5.3 5.62 5.01 5.27 4.85 5.11 5.60 5.89 5.25 5.52 5.09 5.35 6.18 6.50 5.80 6.10 5.62 5.91 6.85 7.20 6.43 6.76 6.22 6.54 7.60 7.99 7.13 7.50 6.90 7.26 89.5 94.2 87.4 92.0 86.0 90.5 90.9 95.7 90.1 94.9 89.4 94.1 90.8 95.6 91.0 95.8 90.9 95.7 89.7 94.4 90.6 95.3 90.9 95.7 87.8 92.4 89.1 93.8 89.7 94.5 85.5 90.0 87.1 91.7 87.8 92.5 84.3 88.7 85.9 90.4 86.7 91.2 83.1 87.4 84.7 89.1 85.5 90.0 80.8 85.0 82.2 86.5 83.0 87.4 78.9 83.0 80.0 84.2 80.6 84.9 77.7 81.8 78.3 82.4 78.7 82.9 23.3 24.0 24.1 24.8 24.4 25.0 21.6 22.2 22.8 23.5 23.4 24.0 19.5 20.1 21.0 21.6 21.7 22.3 17.4 17.8 18.9 19.5 19.7 20.2 15.1 15.6 16.7 17.1 17.5 18.0 13.0 13.4 14.4 14.9 15.2 15.6 12.1 12.4 13.4 13.8 14.1 14.5 11.1 11.4 12.4 12.7 13.0 13.4 9.4 9.7 10.5 10.8 11.1 11.4 7.9 8.1 8.8 9.0 9.3 9.6 6.6 6.8 7.4 7.6 7.8 8.0 3.5 3.7 3.5 3.7 3.5 3.7 3.7 3.9 3.5 3.7 3.5 3.7 4.3 4.5 3.9 4.1 3.7 3.9 5.2 5.5 4.6 4.8 4.3 4.5 6.4 6.7 5.5 5.8 5.1 5.4 7.9 8.3 6.8 7.2 6.4 6.7 8.8 9.3 7.6 8.1 7.1 7.5 9.7 10.2 8.5 8.9 7.9 8.3 11.8 12.4 10.4 10.9 9.7 10.2 14.2 14.9 12.6 13.3 11.9 12.5 16.9 17.8 15.2 16.0 14.3 15.1 Airflow CFM 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 1500 2100 HC kW HE LAT COP HWC 45.8 47.9 49.9 52.1 51.7 54.0 52.7 55.1 56.7 59.3 59.2 61.8 60.5 63.2 64.2 67.1 67.2 70.2 68.8 71.9 71.9 75.1 75.3 78.7 77.2 80.6 79.5 83.1 83.2 87.0 85.2 89.0 86.8 90.7 90.6 94.7 92.6 96.7 90.1 94.2 93.8 98.0 95.6 99.9 93.5 97.7 97.0 101.4 98.7 103.1 5.35 4.76 5.44 4.84 5.47 4.87 5.50 4.89 5.59 4.97 5.64 5.02 5.68 5.05 5.77 5.13 5.83 5.19 5.88 5.23 5.96 5.30 6.06 5.39 6.10 5.43 6.17 5.49 6.28 5.59 6.34 5.64 6.38 5.68 6.51 5.79 6.56 5.84 6.49 5.8 6.6 5.9 6.7 5.9 6.60 5.87 6.72 5.98 6.79 6.04 29.8 31.6 33.5 35.6 35.2 37.4 36.2 38.4 39.9 42.3 42.1 44.7 43.3 46.0 46.7 49.6 49.4 52.4 50.9 54.0 53.7 57.0 56.8 60.3 58.5 62.1 60.6 64.3 64.0 67.9 65.8 69.8 67.2 71.3 70.6 74.9 72.3 76.8 70.2 74.5 73.4 78.0 75.0 79.7 73.1 77.7 76.3 81.0 77.8 82.6 98.3 91.1 100.8 93.0 101.9 93.8 102.5 94.3 105.0 96.1 106.5 97.3 107.3 97.9 109.6 99.6 111.5 100.9 112.5 101.7 114.4 103.1 116.5 104.7 117.6 105.5 119.1 106.6 121.4 108.4 122.6 109.3 123.6 110.0 125.9 111.7 127.1 112.6 125.6 111.5 127.9 113.2 129.0 114.1 127.7 113.1 129.9 114.7 130.9 115.5 2.5 2.9 2.7 3.2 2.8 3.3 2.8 3.3 3.0 3.5 3.1 3.6 3.1 3.7 3.3 3.8 3.4 4.0 3.4 4.0 3.5 4.2 3.6 4.3 3.7 4.4 3.8 4.4 3.9 4.6 3.9 4.6 4.0 4.7 4.1 4.8 4.1 4.9 4.1 4.8 4.2 4.9 4.2 4.9 4.2 4.9 4.2 5.0 4.3 5.0 5.6 5.0 6.0 5.3 6.1 5.4 6.2 5.5 6.5 5.8 6.7 6.0 6.9 6.1 7.2 6.4 7.5 6.7 7.6 6.8 8.0 7.1 8.4 7.5 8.7 7.7 9.0 8.0 9.6 8.5 9.8 8.7 10.1 9.0 10.8 9.6 11.1 9.9 10.7 9.6 11.5 10.2 11.9 10.6 11.4 10.1 12.1 10.8 12.7 11.3 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 27 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TS H/V/D 070 (ECM Blower) 1,950 CFM Nominal (Rated) Airflow Cooling, 2,100 CFM Nominal (Rated) Airflow Heating WPD EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 GPM 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 9.0 9.0 13.5 13.5 18.0 18.0 PSI FT Airflow CFM 9.5 9.5 2.7 2.7 5.2 5.2 8.1 8.1 2.1 2.1 4.4 4.4 7.1 7.1 1.7 1.7 3.8 3.8 6.4 6.4 1.6 1.6 3.5 3.5 5.9 5.9 1.5 1.5 3.3 3.3 5.7 5.7 1.5 1.5 3.2 3.2 5.5 5.5 1.5 1.5 3.2 3.2 5.5 5.5 1.6 1.6 3.2 3.2 5.5 5.5 1.6 1.6 3.2 3.2 5.4 5.4 1.4 1.4 3.1 3.1 5.3 5.3 1.2 1.2 2.9 2.9 5.2 5.2 22.0 22.0 6.3 6.3 12.0 12.0 18.8 18.8 4.9 4.9 10.1 10.1 16.4 16.4 4.0 4.0 8.8 8.8 14.8 14.8 3.6 3.6 8.1 8.1 13.7 13.7 3.5 3.5 7.6 7.6 13.1 13.1 3.5 3.5 7.5 7.5 12.8 12.8 3.6 3.6 7.5 7.5 12.7 12.7 3.6 3.6 7.4 7.4 12.6 12.6 3.6 3.6 7.4 7.4 12.5 12.5 3.3 3.3 7.1 7.1 12.3 12.3 2.7 2.7 6.6 6.6 11.9 11.9 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 1400 1950 TC Cooling - EAT 80/67°F Sens/ SC Tot kW HR Ratio Performance capacities shown in thousands of Btuh Heating - EAT 70°F EER HWC Operation not recommended 77.0 83.2 75.9 82.1 75.0 81.1 77.1 83.4 77.2 83.5 77.0 83.2 75.8 82.0 76.9 83.1 77.1 83.4 73.5 79.5 75.2 81.3 75.9 82.1 70.5 76.2 72.6 78.5 73.6 79.6 66.9 72.3 69.3 74.9 70.5 76.2 64.9 70.1 67.4 72.9 68.7 74.2 62.9 68.0 65.5 70.8 66.8 72.2 58.8 63.6 61.4 66.4 62.8 67.8 54.8 59.2 57.3 61.9 58.6 63.3 51.0 55.2 53.3 57.6 54.5 58.9 44.8 52.7 43.6 51.3 42.8 50.3 45.6 53.6 45.2 53.1 44.8 52.7 45.4 53.5 45.6 53.7 45.6 53.6 44.6 52.5 45.2 53.2 45.5 53.5 43.4 51.0 44.3 52.1 44.7 52.5 41.8 49.2 42.9 50.4 43.4 51.0 41.0 48.2 42.1 49.5 42.6 50.1 40.2 47.3 41.3 48.5 41.8 49.2 38.5 45.3 39.6 46.5 40.1 47.2 37.0 43.6 37.9 44.6 38.4 45.2 35.9 42.2 36.5 43.0 36.9 43.4 0.58 0.63 0.57 0.63 0.57 0.62 0.59 0.64 0.59 0.64 0.58 0.63 0.60 0.65 0.59 0.65 0.59 0.64 0.61 0.66 0.60 0.65 0.60 0.65 0.62 0.67 0.61 0.66 0.61 0.66 0.63 0.68 0.62 0.67 0.62 0.67 0.63 0.69 0.62 0.68 0.62 0.68 0.64 0.69 0.63 0.69 0.63 0.68 0.65 0.71 0.64 0.70 0.64 0.70 0.68 0.74 0.66 0.72 0.66 0.71 0.70 0.76 0.69 0.75 0.68 0.74 2.86 3.01 2.67 2.81 2.58 2.71 3.16 3.32 2.95 3.10 2.85 3.00 3.47 3.65 3.25 3.42 3.15 3.31 3.82 4.02 3.58 3.76 3.46 3.64 4.21 4.43 3.94 4.14 3.81 4.01 4.66 4.90 4.36 4.58 4.21 4.43 4.9 5.17 4.59 4.83 4.44 4.67 5.17 5.44 4.83 5.08 4.67 4.91 5.76 6.06 5.37 5.65 5.19 5.46 6.44 6.77 6.01 6.32 5.80 6.10 7.24 7.61 6.74 7.09 6.50 6.84 88.8 93.5 87.1 91.6 85.8 90.4 90.0 94.7 89.3 94.0 88.8 93.4 89.7 94.5 90.0 94.8 89.9 94.7 88.6 93.2 89.5 94.2 89.8 94.5 86.7 91.3 88.0 92.7 88.6 93.3 84.5 89.0 86.0 90.6 86.8 91.3 83.4 87.8 84.9 89.4 85.6 90.1 82.2 86.6 83.7 88.2 84.5 89.0 80.1 84.3 81.4 85.7 82.1 86.5 78.2 82.4 79.3 83.5 79.9 84.1 77.1 81.1 77.7 81.8 78.1 82.2 26.9 27.7 28.4 29.2 29.1 29.9 24.4 25.1 26.2 26.9 27.0 27.7 21.8 22.5 23.6 24.3 24.5 25.2 19.2 19.8 21.0 21.6 21.9 22.6 16.7 17.2 18.5 19.0 19.3 19.9 14.3 14.8 15.9 16.4 16.7 17.2 13.3 13.6 14.7 15.2 15.5 16.0 12.2 12.5 13.6 13.9 14.3 14.7 10.2 10.5 11.4 11.8 12.1 12.4 8.5 8.8 9.5 9.8 10.1 10.4 7.1 7.3 7.9 8.1 8.4 8.6 3.5 3.7 3.5 3.7 3.5 3.7 3.7 3.9 3.5 3.7 3.5 3.7 4.3 4.5 3.9 4.1 3.7 3.9 5.2 5.5 4.6 4.8 4.3 4.5 6.4 6.7 5.5 5.8 5.1 5.4 7.9 8.3 6.8 7.2 6.4 6.7 8.8 9.3 7.6 8.1 7.1 7.5 9.7 10.2 8.5 8.9 7.9 8.3 11.8 12.4 10.4 10.9 9.7 10.2 14.2 14.9 12.6 13.3 11.9 12.5 16.9 17.8 15.2 16.0 14.3 15.1 Airflow CFM 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 1475 2050 HC kW HE LAT COP HWC 44.7 46.7 48.7 50.9 50.5 52.7 51.5 53.8 55.5 58.0 57.9 60.5 59.2 61.9 62.9 65.8 65.9 68.9 67.5 70.6 70.6 73.8 74.1 77.4 75.9 79.3 78.3 81.8 82.0 85.7 84.0 87.8 85.6 89.5 89.5 93.5 91.4 95.5 89.0 93.0 92.7 96.8 94.5 98.7 92.3 96.5 95.9 100.2 97.6 102.0 4.97 4.42 5.06 4.50 5.10 4.54 5.13 4.56 5.23 4.65 5.28 4.70 5.32 4.73 5.41 4.81 5.49 4.88 5.52 4.91 5.61 4.99 5.70 5.07 5.75 5.12 5.82 5.18 5.93 5.28 6.00 5.34 6.06 5.39 6.18 5.50 6.26 5.57 6.18 5.5 6.3 5.6 6.4 5.7 6.29 5.60 6.45 5.74 6.53 5.81 29.8 31.6 33.4 35.5 35.1 37.3 36.0 38.2 39.7 42.2 41.9 44.5 43.1 45.8 46.5 49.4 49.2 52.2 50.7 53.8 53.5 56.8 56.6 60.1 58.3 61.9 60.4 64.1 63.8 67.7 65.6 69.6 67.0 71.1 70.4 74.7 72.1 76.5 69.9 74.3 73.2 77.7 74.7 79.3 72.9 77.4 75.9 80.6 77.4 82.1 98.1 91.1 100.5 93.0 101.7 93.8 102.3 94.3 104.8 96.2 106.4 97.3 107.2 98.0 109.5 99.7 111.4 101.1 112.4 101.9 114.3 103.3 116.5 105.0 117.7 105.8 119.2 107.0 121.5 108.7 122.7 109.7 123.8 110.4 126.2 112.2 127.4 113.1 125.9 112.0 128.2 113.7 129.3 114.6 128.0 113.6 130.2 115.3 131.3 116.1 2.6 3.1 2.8 3.3 2.9 3.4 2.9 3.5 3.1 3.7 3.2 3.8 3.3 3.8 3.4 4.0 3.5 4.1 3.6 4.2 3.7 4.3 3.8 4.5 3.9 4.5 3.9 4.6 4.1 4.8 4.1 4.8 4.1 4.9 4.2 5.0 4.3 5.0 4.2 5.0 4.3 5.1 4.3 5.1 4.3 5.1 4.4 5.1 4.4 5.1 5.6 5.0 6.0 5.3 6.1 5.4 6.2 5.5 6.5 5.8 6.7 6.0 6.9 6.1 7.2 6.4 7.5 6.7 7.6 6.8 8.0 7.1 8.4 7.5 8.7 7.7 9.0 8.0 9.6 8.5 9.8 8.7 10.1 9.0 10.8 9.6 11.1 9.9 10.7 9.6 11.5 10.2 11.9 10.6 11.4 10.1 12.1 10.8 12.7 11.3 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 28 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Air Flow Correction Table - Units with PSC Fan TS006-018 with PSC Fan Motor Airflow Cooling % of Rated Total Capacity Sensible Capacity S/T 75 0.9602 0.8350 81.25 0.9724 87.50 0.9831 93.75 100 Heating Power Heat of Rejection Heating Capacity Power Heat of Extraction 0.8696 0.9675 0.9617 0.9740 1.0936 0.9425 0.8733 0.8981 0.9744 0.9728 0.9810 1.0635 0.9592 0.9149 0.9306 0.9821 0.9829 0.9876 1.0379 0.9744 0.9923 0.9578 0.9653 0.9906 0.9920 0.9940 1.0167 0.9880 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 106.25 1.0062 1.0392 1.0328 1.0102 1.0070 1.0057 0.9878 1.0105 112.50 1.0109 1.0733 1.0617 1.0211 1.0130 1.0112 0.9800 1.0194 118.75 1.0141 1.1001 1.0848 1.0329 1.0180 1.0163 0.9705 1.0284 125 1.0159 1.1174 1.0999 1.0455 1.0220 1.0211 0.9614 1.0368 TS024-070 with PSC Fan Motor Airflow Cooling Heating % of Rated Total Capacity Sensible Capacity S/T Power Heat of Rejection Heating Capacity Power Heat of Extraction 72 0.925 0.850 0.919 0.951 0.950 0.957 1.124 0.942 80 0.954 0.903 0.946 0.966 0.968 0.973 1.072 0.963 88 0.974 0.941 0.966 0.977 0.982 0.984 1.037 0.979 0.994 96 0.992 0.981 0.989 0.992 0.995 0.995 1.010 100 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 104 1.007 1.018 1.011 1.009 1.005 1.005 0.993 1.006 112 1.017 1.052 1.035 1.027 1.013 1.012 0.986 1.015 120 1.023 1.082 1.058 1.047 1.019 1.019 0.990 1.022 ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 29 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Air Flow Correction Table - Units with ECM Fan TS018 with ECM Fan Motor Airflow Cooling % of Rated Total Capacity Sensible Capacity S/T 75 0.9619 0.8593 81.25 0.9747 87.50 0.9853 93.75 100 Heating Power Heat of Rejection Heating Capacity Power Heat of Extraction 0.8933 0.9455 0.9587 0.9700 1.0822 0.9410 0.8943 0.9175 0.9564 0.9711 0.9775 1.0536 0.9579 0.9302 0.9441 0.9691 0.9821 0.9851 1.0304 0.9733 0.9938 0.9659 0.9719 0.9837 0.9918 0.9925 1.0125 0.9874 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 106.25 1.0041 1.0313 1.0271 1.0181 1.0069 1.0074 0.9928 1.0112 112.50 1.0060 1.0584 1.0522 1.0381 1.0123 1.0148 0.9909 1.0210 118.75 1.0070 1.0815 1.0740 1.0598 1.0174 1.0222 0.9622 1.0377 125 1.0076 1.0998 1.0916 1.0834 1.0225 1.0295 0.8681 1.0712 TS024-070 with ECM Fan Motor Airflow Cooling Heating % of Rated Total Capacity Sensible Capacity S/T Power Heat of Rejection Heating Capacity Power Heat of Extraction 72 0.925 0.850 0.919 0.951 0.950 0.957 1.124 0.942 80 0.954 0.903 0.946 0.966 0.968 0.973 1.072 0.963 88 0.974 0.941 0.966 0.977 0.982 0.984 1.037 0.979 96 0.992 0.981 0.989 0.992 0.995 0.995 1.010 0.994 100 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 104 1.007 1.018 1.011 1.009 1.005 1.005 0.993 1.006 112 1.017 1.052 1.035 1.027 1.013 1.012 0.986 1.015 120 1.023 1.082 1.058 1.047 1.019 1.019 0.990 1.022 ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 30 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Entering Air Correction Tables Unit Sizes 006-018 Unit Sizes 024-070 Heating Heating Entering Heat Heating Air DB Power of Capacity Extraction °F 1.0514 0.7749 1.1240 45 Entering Heat Heating Air DB Power of Capacity Extraction °F 1.032 0.777 1.089 45 50 1.0426 0.8113 1.1032 50 1.029 0.817 1.077 55 1.0329 0.8525 1.0802 55 1.025 0.859 1.062 60 1.0224 0.8980 1.0551 60 1.018 0.903 1.044 65 1.0114 0.9473 1.0282 65 1.010 0.950 1.024 68 1.0046 0.9786 1.0115 70 1.000 1.000 1.000 1.0000 75 0.988 1.052 0.974 80 0.974 1.107 0.944 70 1.0000 1.0000 75 0.9883 1.0556 0.9706 80 0.9764 1.1135 0.9404 Unit Sizes 006-018 Cooling Entering Air WB°F Total Capacity Sensible Cooling Capacity Multiplier Entering DB °F 60 65 Power 70 75 80 80.6 85 90 95 Heat of Rejection 50 0.7432 0.9111 * * * * * * * * 0.9866 0.7901 55 0.8202 0.7709 0.8820 1.0192 * * * * * * 0.9887 0.8527 60 0.8960 0.6702 0.8540 1.0473 * * * * * 0.9924 0.9146 65 0.9705 0.6491 0.8657 1.0809 1.1066 * * * 0.9975 0.9757 66.2 0.9882 0.5939 0.8152 1.0333 1.0592 1.2481 * * 0.9990 0.9903 67 1.0000 0.5559 0.7801 1.0000 1.0261 1.2158 * * 1.0000 1.0000 70 1.0438 0.6377 0.8645 0.8913 1.0847 1.2983 * 1.0042 1.0362 75 1.1159 0.6008 0.6289 0.8323 1.0578 1.2773 1.0123 1.0959 Power Heat of Rejection Operation not recommended Unit Sizes 024-070 Cooling Entering Air WB°F Total Capacity Sensible Cooling Capacity Multiplier Entering DB °F 60 65 70 75 80 80.6 85 90 95 50 0.7491 0.7663 * * * * * * * * 0.9894 0.8389 55 0.8265 0.5937 0.8724 1.0816 * * * * * * 0.9927 0.8886 60 0.9040 0.6709 0.8826 1.1211 * * * * * 0.9959 0.9383 65 0.9814 0.6624 0.8850 1.0986 1.1140 * * * 0.9992 0.9881 66.2 1.0000 0.6065 0.8268 1.0394 1.0536 1.2294 * * 1.0000 1.0000 67 1.0124 0.5685 0.7879 1.0000 1.0133 1.1891 1.3838 * 1.0005 1.0080 70 1.0589 0.6391 0.8521 0.8599 1.0361 1.2347 1.4461 1.0025 1.0378 75 1.1363 0.6056 0.5981 0.7783 0.9861 1.2256 1.0058 1.0875 Operation not recommended * = Sensible capacity equals total capacity AHRI/ISO/ASHRAE 13256-1 uses entering air conditions of Cooling - 80.6°F DB/66.2°F WB, 1 and Heating - 68°F DB/59°F WB entering air temperature For ClimaDry® equipped units the minimum entering air temperature when cooling is 65ºF DB / 55ºF WB. Operation below this minimum may result in nuisance faults. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 31 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Correction Tables - Antifreeze and Water Pressure Drop Adder for Options Cooling Heating EWT 90°F EWT 30°F Antifreeze Type Antifreeze % Total Cap Sens Cap Power Htg Cap Power WPD Corr. Fct. EWT 30°F Water 0 1.000 1.000 1.000 1.000 1.000 1.000 5 0.995 0.995 1.003 0.989 0.997 1.070 15 0.986 0.986 1.009 0.968 0.990 1.210 25 0.978 0.978 1.014 0.947 0.983 1.360 5 0.997 0.997 1.002 0.989 0.997 1.070 15 0.990 0.990 1.007 0.968 0.990 1.160 25 0.982 0.982 1.012 0.949 0.984 1.220 5 0.998 0.998 1.002 0.981 0.994 1.140 15 0.994 0.994 1.005 0.944 0.983 1.300 25 0.986 0.986 1.009 0.917 0.974 1.360 5 0.998 0.998 1.002 0.993 0.998 1.040 15 0.994 0.994 1.004 0.980 0.994 1.120 25 0.988 0.988 1.008 0.966 0.990 1.200 Propylene Glycol Methanol Ethanol Ethylene Glycol ClimaDry® II Option Corrections (When Operating in Non-ClimaDry® Mode) Motorized Water Valve Option Corrections Model Cv 4.9 006 009 012 018 024 030 036 042 048 060 070 MOPD 150 WPD Adders GPM PSI FT 1.0 0.04 0.10 4.9 150 1.5 0.09 0.22 4.9 150 2.0 0.17 0.38 4.9 150 1.4 0.08 0.19 4.9 150 2.1 0.18 0.42 4.9 150 2.8 0.33 0.75 4.9 150 1.8 0.13 0.31 4.9 150 2.6 0.28 0.65 4.9 150 3.5 0.51 1.18 10.3 125 2.8 0.07 0.16 10.3 125 4.1 0.16 0.37 10.3 125 5.5 0.29 0.66 10.3 125 4.0 0.15 0.35 10.3 125 6.0 0.34 0.78 10.3 125 8.0 0.60 1.39 10.3 125 4.0 0.15 0.35 10.3 125 6.0 0.34 0.78 10.3 125 8.0 0.60 1.39 10.3 125 4.5 0.19 0.44 10.3 125 6.8 0.43 0.99 10.3 125 9.0 0.76 1.76 10.3 125 5.5 0.29 0.66 10.3 125 8.3 0.64 1.48 10.3 125 11.0 1.14 2.63 10.3 125 6.0 0.34 0.78 10.3 125 9.0 0.76 1.76 10.3 125 12.0 1.36 3.14 8.9 125 7.5 0.71 1.64 8.9 125 11.3 1.60 3.69 8.9 125 15.0 2.84 6.56 8.9 125 8.3 0.86 1.98 8.9 125 12.4 1.93 4.47 8.9 125 16.5 3.44 7.94 Model 018 024 030 036 042 048 060 070 GPM 2.8 4.1 4.0 6.0 4.0 6.0 4.5 6.8 5.5 8.3 6.0 9.0 7.5 11.3 8.3 WPD Adders PSI 0.77 1.65 1.57 3.53 0.69 1.55 0.87 1.99 1.30 6.75 1.55 3.49 1.49 3.39 1.83 FT 1.77 3.80 3.62 8.14 1.59 3.58 2.02 4.60 3.01 15.58 3.58 8.06 3.45 7.82 4.22 12.4 4.08 9.42 ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 32 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Blower Performance Data – Standard Unit - No Reheat (PSC Motor) Airflow in CFM with wet coil and clean air filter Model Fan Speed Rated Airflow Min CFM HI 006 MED 240 150 LO HI 009 MED 012 225 0.50 0.60 0.70 271 250 230 203 168 260 245 230 214 190 167 216 201 189 156 393 378 364 346 325 253 366 353 341 326 310 230 316 303 290 274 500 479 453 403 347 459 447 428 411 368 317 LO 371 368 358 345 315 HI 704 711 693 690 675 640 598 602 599 581 585 573 547 492 350 600 300 450 531 527 517 506 495 462 894 877 841 812 760 728 659 765 755 738 711 668 640 602 683 661 636 596 571 549 1111 1105 1066 1006 934 854 765 662 890 879 854 818 770 708 686 623 024 MED 450 HI 950 655 LO 759 745 730 704 662 627 1374 1351 1296 1228 1159 1090 1016 919 775 1146 1151 1128 1091 1047 997 934 844 705 1011 1015 999 945 911 863 785 656 1374 1351 1296 1228 1159 1090 1016 919 775 1146 1151 1128 1091 1047 997 934 844 705 1011 1015 999 945 911 863 785 HS MED 030 MED 950 655 HS LO HI 1000 685 LO HS HI 1342 1316 1249 1166 1083 1006 927 830 688 1298 1250 1183 1110 1039 969 894 796 652 HS LO 1213 1172 1112 1046 982 919 850 758 623 HI 1375 1387 1377 1350 1307 1251 1182 1099 1003 890 992 1013 1013 1002 986 967 941 900 832 719 887 900 897 886 872 853 826 785 HS MED MED 1000 1200 685 825 LO HS HI 1751 1717 1664 1592 1503 1399 1285 1163 1039 919 1538 1520 1485 1432 1361 1271 1165 1049 926 804 HS LO 1321 1294 1263 1226 1182 1130 1064 980 871 729 HI 1808 1759 1723 1680 1617 1524 1399 1247 1075 1001 HS MED MED 1200 1537 1518 1494 1459 1408 1338 1247 1134 LO 1323 1309 1284 1246 1192 1122 1036 936 824 HS HI 1805 1791 1760 1720 1674 1620 1552 1457 1318 1116 1296 1297 1299 1299 1293 1276 1240 1176 1072 915 991 998 1013 1019 1004 963 894 804 705 042 HS HS MED 048 MED 1400 825 1400 960 960 HS LO HI 1.00 635 HS HI 024 HS 0.90 515 LO 600 0.80 312 HS HI HS LO 042 0.40 285 326 HS MED 036 HS 0.30 305 520 MED 036 0.20 317 HI 018 HS 030 HS 0.10 LO MED 018 300 Airflow (cfm) at External Static Pressure (in. wg) 0.00 1805 1791 1760 1720 1674 1620 1552 1457 1318 1116 1600 1100 1296 1297 1299 1299 1293 1276 1240 1176 1072 915 1871 1889 1873 1833 1777 1706 1617 1504 1353 1150 1600 1100 1663 1680 1686 1678 1650 1599 1520 1409 1262 1075 LO 048 HS HS HI HS MED 060 060 HS HS LO 1479 1508 1521 1516 1492 1446 1376 1249 1148 981 HI 2311 2300 2279 2257 2209 2140 2088 1990 1901 1856 1752 2058 2039 2016 1983 1949 1920 1874 1807 1750 1670 1582 MED 1950 1500 LO 1868 1858 1858 1838 1806 1792 1749 1699 1636 1570 HS HI 2510 2486 2455 2424 2377 2318 2247 2161 2078 1986 1855 2171 2162 2162 2153 2117 2085 2024 1971 1891 1823 1691 HS MED 070 Operation not recommended 1950 1500 HS LO 2010 2006 2006 2006 1977 1947 1892 1851 1782 1705 1600 HI 2510 2486 2455 2424 2377 2318 2247 2161 2078 1986 1855 2171 2162 2162 2153 2117 2085 2024 1971 1891 1823 2010 2006 2006 2006 1977 1947 1892 1851 MED LO 2100 1800 Black areas denote ESP where operation is not recommended. Units factory shipped on medium speed. Other speeds require field selection. All airflow is rated and shown above at the lower voltage if unit is dual voltage rated, e.g. 208V for 208-230V units. Only two speed fan (H & M) available on 575V units. Performance stated is at the rated power supply, performance may vary as the power supply varies from the rated. HS = High static fan option ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 33 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Blower Performance Data – Units with ClimaDry® (PSC Motor) Coil Face Velocity FPM TSH/V/D with Reheat ESP Loss TSH/V/D 018 In. of Water TSH/V/D 024, 030 In. of Water TSH/V/D 036 In. of Water TSH/V/D 042, 048 In. of Water TSH/V/D 060, 070 In. of Water 200 0.037 0.033 0.031 0.028 0.026 250 0.052 0.046 0.042 0.038 0.034 300 0.077 0.066 0.059 0.051 0.044 350 0.113 0.096 0.085 0.073 0.061 400 0.181 0.160 0.145 0.131 0.117 450 0.242 0.226 0.215 0.205 0.194 500 0.360 0.345 0.335 0.326 0.316 For TS units with ClimaDry® Reheat coil applications, calculate face velocity of the entering air. From the table above, find ESP for Reheat application. The loss includes wet coil loss. Example: Reheat coil loss can be determined from the above table. Coil velocity (FPM) = Airflow (CFM) / Face Area (sq. ft.) 1. 2. 3. 4. TSH036 has a face area of 4.86 sq. ft. (see physical data table). At 1,100 cfm, coil velocity (FPM) = 1,100 / 4.86 = 226 FPM From above table, it will be necessary to subtract 0.037 from the blower performance ESP. On medium speed, the TSH036 (without reheat - see blower table) can deliver 1,100 CFM at 0.28 in. wg. with the standard PSC motor; with the reheat coil, it now delivers 1,085 CFM at 0.28 in. wg. or 1,100 CFM at 0.24 in. wg. 5. If the decrease in airflow is acceptable, no changes are necessary. Otherwise, high speed fan should be used to overcome the pressure drop of the reheat coil. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 34 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P ECM Control The ECM fan is controlled by an interface board that converts thermostat inputs and field selectable CFM settings to signals used by the ECM motor controller. Units manufactured after July 2005 have version II (P/N 17B0019N01). Fan speeds are selected with a nine position DIP switch for version II. To take full advantage of the ECM motor features, a multi-stage thermostat should be used (2-stage heat/2-stage cool or 3-stage heat/2-stage cool). HFC-410A packaged units built after May 2009 have ECM controller version III (P/N 17B0034N01). This controller includes logic and a relay to control the HWG functions. Note: Power must be off to the unit for at least three seconds before the ECM motor will recognize a speed change. The motor will recognize a change in the CFM Adjust or dehumidification mode settings while the unit is powered. There are four different airflow settings from lowest airflow rate (speed tap 1) to the highest airflow rate (speed tap 4). The charts below indicate settings for both versions of the ECM interface board, followed by detailed information for each setting. WARNING! When the disconnect switch is closed, high voltage is present in some areas of the electrical panel. Exercise caution when working with energized equipment. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 35 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P ECM Control The ECM motor includes “soft start” and “ramp down” features. The soft start feature is a gentle increase of motor rpm at blower start up. This creates a much quieter blower start cycle. The ramp down feature allows the blower to slowly decrease rpm to a full stop at the end of each blower cycle. This creates a much quieter end to each blower cycle and adds overall unit efficiency. The ramp down feature may be eliminated during an ESD (Emergency Shut Down) situation when using a DXM unit controller. A DPDT relay is required to break the line voltage to the ECM motor during ESD. This relay can be wired as shown below to eliminate the ramp down (and operation) of the ECM blower motor. To ‘ESD’ on DXM To ‘R’ on DXM ESD Signal (field input) Cooling Settings: The cooling setting determines the cooling (normal) CFM for all units with ECM motor. Cooling (normal) setting is used when the unit is not in dehumidification mode. Tap 1 is the lowest CFM setting, while tap 4 is the highest CFM setting. To avoid air coil freeze-up, tap 1 may not be used if the dehumidification mode is selected. Consult submittal data or specifications catalog for the specific unit series and model to correlate speed tap setting to airflow in CFM. Heating Settings: The heating setting determines the heating CFM for Tranquility® 30 (TT) and Tranquility® 20 (TS) units. Tap 1 is the lowest CFM setting, while tap 4 is the highest CFM setting. Consult submittal data or specifications catalog for the specific unit series and model to correlate speed tap setting to airflow in CFM. Auxiliary/Emergency Heat Settings: The auxiliary/emergency heat setting determines the CFM when the unit is in auxiliary heat or emergency heat mode. This setting is used for residential units with internal electric heat. When auxiliary electric heat is energized (i.e. compressor and electric heat), the greater of the auxiliary/emergency or heating setting will be used. A “G” (fan) signal must be present from the thermostat for electric heat to operate. Consult the submittal data or specifications catalog for the specific unit series and model to correlate speed tap setting to airflow in CFM. CFM Adjust Settings: The CFM adjust setting allows four selections. The NORM setting is the factory default position. The + or – settings adjust the airflow by +/- 5%. The +/- settings are used to “fine tune” airflow adjustments. The TEST setting runs the ECM motor at 400 cfm/ton, which causes the motor to operate like a standard PSC motor, and disables the CFM counter. Dehumidification Mode Settings: The dehumidification mode setting provides field selection of humidity control. When operating in ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 36 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P ECM Control the normal mode, the cooling airflow settings are determined by the cooling tap setting above. When dehumidification is enabled there is a reduction in airflow in cooling to increase the moisture removal of the heat pump. Consult submittal data or specifications catalog for the specific unit series and model to correlate speed tap to airflow in CFM. The dehumidification mode can be enabled in two ways. 1. 2. Constant Dehumidification Mode: When the dehumidification mode is selected (via DIP switch or jumper setting), the ECM motor will operate with a multiplier applied to the cooling CFM settings (approx. 20-25% lower airflow). Any time the unit is running in the cooling mode, it will operate at the lower airflow to improve latent capacity. The “DEHUM” LED will be illuminated at all times. Heating airflow is not affected. NOTE: Do not select dehumidification mode if cooling setting is tap 1. Automatic (Humidistat-controlled) Dehumidification Mode: When the dehumidification mode is selected (via DIP switch or jumper setting) AND a humidistat is connected to terminal DH (version II) or HUM (version I), the cooling airflow will only be reduced when the humidistat senses that additional dehumidification is required. The DH (or HUM) terminal is reverse logic. Therefore, a humidistat (not dehumidistat) is required. The “DEHUM” LED will be illuminated only when the humidistat is calling for dehumidification mode. Heating airflow is not affected. NOTE: Do not select dehumidification mode if cooling setting is tap 1. G Y1 Y2 O W R 1/4" Spade Connections to CXM or DXM Board G G G G R Thermostat Input LEDs C TB1 CFM CFM Counter 1 flash per 100 CFM Y ECM Motor Low Voltage Connector J1 DEHUM AL1 S1 SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 SW9 OFF ON G A Dehumidification LED Y2 Y1 G O W C R DH AL1 A Thermostat Connections Fan Speed Selection DIP Switch ECM Interface Board version II (P/N 17B0019N01) ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 37 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Blower Performance Data – (ECM Motor) - Standard Unit - No Reheat Residential Units Only Airflow in CFM with wet coil and clean air filter Model 018 024 030 036 042 048 060 070 Max ESP (in. wg) 1.0 1.0 1.0 0.90 0.90 1.0 0.75 0.75 Fan Motor (hp) 1/2 1/2 1/2 1/2 1/2 1 1 1 Cooling Mode Tap Setting Stg 1 4 3 Dehumid Mode Heating Mode Aux/ Emerg Mode Stg 2 Fan Stg 1 Stg 2 Fan Stg 1 Stg 2 Fan AUX CFM 640 800 400 500 620 400 640 800 400 4 800 600 750 375 470 590 375 600 750 375 3 750 2 525 650 330 400 500 330 525 650 330 2 650 1 450 550 280 450 550 280 1 650 4 900 1100 470 Operation not recommended 610 740 470 900 1100 470 4 1100 3 780 950 420 540 660 420 780 950 420 3 950 2 670 825 360 490 600 360 670 825 390 2 820 1 550 675 300 550 675 340 1 690 4 920 1130 560 720 880 560 1000 1230 560 4 1230 3 820 1000 500 640 780 500 900 1100 500 3 1100 2 740 900 450 580 700 450 800 950 450 2 950 1 660 800 400 640 780 400 1 780 4 1150 1400 700 900 1090 700 1150 1400 700 4 1400 3 1020 1250 630 800 980 630 1020 1250 630 3 1350 2 890 1080 540 690 840 540 890 1080 540 2 1350 1 740 900 450 750 920 450 1 1350 4 1290 1580 790 1010 1230 790 1290 1580 790 4 1580 3 1150 1400 700 900 1090 700 1150 1400 700 3 1400 2 1050 1280 640 820 1000 640 1020 1240 640 2 1350 1 920 1120 560 900 1080 560 1 1350 4 1420 1730 870 1110 1350 870 1520 1850 865 4 1850 3 1270 1550 780 990 1210 780 1350 1650 775 3 1650 2 1180 1440 720 920 1120 720 1110 1350 720 2 1350 1 1050 1280 640 980 1250 640 1 1200 4 1680 2050 1030 3 1500 1830 2 1400 1700 1 1300 1580 790 4 1830 2230 1100 1420 1740 3 1600 1950 980 1250 2 1440 1750 880 1120 1 1200 1580 790 1310 1600 1030 1870 2280 1030 4 2280 910 1170 1420 910 1680 2050 910 3 2050 850 1090 1330 850 1480 1800 850 2 1800 1270 1550 790 1 1550 1100 1830 2230 1100 4 2230 1520 980 1720 2100 980 3 2100 1360 880 1670 1950 880 2 1950 1460 1780 790 1 1780 See ECM control section for details on setting taps. Bold numbers indicate factory settings. During Auxiliary operation the CFM will run at the higher of the Heating (Delay jumper) or AUX settings. Airflow is controlled within 5% up to the Max ESP shown with wet coil. Do not select Dehumidification mode if HP CFM is on setting 1. All units AHRI/ISO/ASHRAE 13256-1 rated HP CFM Setting 3. Tranquility® 20 (TS) Series with ClimaDry® Reheat Option (ECM Motor) All Tranquility® 20 (TS) units with optional ECM fan motor automatically adjusts for the reheat coil. The small additional pressure drop of the reheat coil causes the ECM motor to slightly increase RPM to overcome the added pressure drop, and maintain selected CFM up to the maximum ESP. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 38 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P ClimaDry® II Option - Benefits and Application ClimaDry® II Modulating Reheat Option ClimateMaster’s patented ClimaDry® II Dehumidification option is an innovative means of providing modulating reheat without the complication of refrigeration controls. ClimaDry® II is hot gas generated reheat, which utilizes one of the biggest advantages of a Water-Source Heat Pump (WSHP), the transfer of energy through the water piping system. ClimaDry® II simply diverts condenser water through a water-to-air coil that is placed after the evaporator coil. If condenser water is not warm enough, the internal “run-around” loop increases the water temperature with each pass through the condenser coil (see figure 1, below). ClimaDry® II Benefits ClimaDry® II is like no other reheat option on the market. Proportional reheat is controlled to the desired leaving air temperature setpoint (factory setpoint of 72°F, 22°C), no matter what the water loop temperature is. Since dehumidification operation will occur under less than full load cooling conditions a good percentage of the time, it is important to have a reheat function that provides 100% reheat in the spring and fall when the water loop is cool. Supply air temperature is field adjustable to +/- 3°F [+/- 1.7°C] for even greater flexibility with the optional potentiometer. It is recommended that the ClimaDry® supply air temperature be set to match the space cooling setpoint so that ClimaDry® does not impact room temperature. Competitors without ClimaDry® II typically use an on/off (non-modulating) refrigeration based reheat circuit, typically referred to as “Hot gas reheat” (HGR). HGR needs higher condensing temperatures to work well, typically 85°F [29°C] entering water temperature (EWT). With HGR, cooler water temperatures produce cooler supply air temperatures, which could overcool the space, requiring additional space heating from another source or a special auto-change-over relay to allow the unit to switch back and forth between reheat and heating. Rarely does HGR provide 100% reheat, like ClimaDry® II. ClimaDry® II has a simple and easy to troubleshoot refrigerant circuit. No switching valves or hard to diagnose leaky check valves are utilized. No unusual refrigerant pressures occur during the reheat mode. The ClimaDry® II refrigerant circuit is like every other ClimateMaster unit (without reheat), so everything the technician already knows applies to troubleshooting the ClimaDry® II refrigeration circuit. Plus, the water loop portion of the ClimaDry® II option is easy to understand and diagnose. ClimaDry® II Applications ClimaDry® II can be applied to a number of common applications, such as: • Classrooms. • Condominiums. • Apartments. • Computer rooms. • Spaces with high latent loads like auditoriums, theaters, convention centers, etc. • Most applications where humidity is a problem. (Note: ClimaDry® is not for use in high fraction outdoor air applications or in applications with corrosive atmospheres, such as pool rooms.) Figure 1: ClimaDry® II Schematic WATER OUT (TO WATER LOOP) MODULATING MIXING VALVE REFRIGERANT IN (COOLING) WATER IN (FROM WATER LOOP) INTERNAL PUMP COAX REFRIGERANT OUT (COOLING) 1RWH $OOFRPSRQHQWVVKRZQ DUHLQWHUQDOWRWKHKHDW SXPSXQLW ENTERING AIR EVAPORATOR COIL LEAVING AIR REHEAT COIL ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 39 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P ClimaDry® II Option - Benefits and Application With the ClimaDry® II option, return air from the space is cooled by the air-to-refrigerant (evaporator) coil, and then reheated by the water-to-air (reheat) coil to dehumidify the air, but maintain the same space temperature (thus operating as a dehumidifier). The moisture removal capability of the heat pump is determined by the unit’s latent capacity rating. Latent capacity equals Total capacity minus Sensible capacity. Using unit performance data from submittals (http://www. climatemaster.com/) select the correct model, use your maximum entering water temperature (EWT) and flow rate to select TC and SC. For example, at 80°F [26.7°C] EWT and 6.8 GPM, the moisture removal capability (latent capacity) of a ClimateMaster TS036 is 8.1 Mbtuh [2.4kW] as shown below. Most ClimateMaster heat pumps have a sensible-to-total (S/T) ratio of 0.72 to 0.82. Therefore, approximately, 25% of the cooling capacity is dedicated to latent cooling capacity (moisture removal). When selecting a unit with ClimaDry® II, the space sensible and latent loads should be calculated. If the unit will be used for space cooling, a unit with at least enough capacity to satisfy the building sensible load should be selected. If the latent cooling load is not satisfied by the selection, a larger unit with enough latent capacity will be required. If the unit will be used for dehumidification purposes only, the latent capacity is the only consideration necessary. In this case, sensible load is immaterial. Dividing the latent capacity by 1,069 BTU/LB of water vapor at 80°F DB and 67°F WB [26.7°C DB and 19.4°C WB] moist air enthalpy, converts the amount of moisture removal to pounds per hour (multiply pounds per hour by 0.4536 to obtain kg/hr). Calculations are shown below. Example TS036 PSC Blower Performance LC = TC - SC = 32.3 - 24.2 = 8.1 Mbtuh 8,100 Btuh ÷ 1069 = 7.6 lbs/hr EWT °F 70 80 85 90 WPD Cooling - EAT 80/67°F Heating - EAT 70°F GPM 4.5 4.5 6.8 6.8 4.5 4.5 6.8 6.8 4.5 4.5 6.8 6.8 4.5 4.5 6.8 6.8 PSI FT Airflow CFM TC SC Sens/Tot Ratio kW HR EER Airflow CFM HC kW HE LAT COP 1.1 1.1 2.9 2.9 1.0 1.0 2.8 2.8 1.0 1.0 2.7 2.7 0.9 0.9 2.6 2.6 2.5 2.5 6.7 6.7 2.3 2.3 6.5 6.5 2.2 2.2 6.2 6.2 2.1 2.1 6.0 6.0 940 1250 940 1250 940 1250 940 1250 940 1250 940 1250 940 1250 940 1250 32.8 34.2 34.0 35.4 30.8 32.1 32.0 33.4 29.8 31.1 31.0 32.3 28.9 30.1 30.0 31.2 21.0 25.1 21.4 25.6 20.2 24.1 20.6 24.7 19.8 23.7 20.2 24.2 19.4 23.3 19.8 23.7 0.64 0.73 0.63 0.72 0.65 0.75 0.64 0.74 0.66 0.76 0.65 0.75 0.67 0.77 0.66 0.76 2.06 2.13 1.96 2.02 2.25 2.32 2.13 2.21 2.36 2.44 2.24 2.31 2.47 2.55 2.34 2.42 39.9 41.4 40.7 42.3 38.5 40.0 39.3 40.9 37.9 39.4 38.6 40.2 37.3 38.8 38.0 39.5 15.9 16.0 17.4 17.5 13.7 13.8 15.0 15.1 12.7 12.8 13.9 14.0 11.7 11.8 12.8 12.9 940 1250 940 1250 940 1250 940 1250 940 1250 940 1250 940 1250 940 1250 37.9 38.9 39.7 40.7 41.6 42.7 43.6 44.8 43.4 44.6 45.6 46.8 45.3 46.5 47.6 48.9 2.65 2.42 2.68 2.45 2.72 2.48 2.75 2.52 2.75 2.52 2.79 2.55 2.79 2.55 2.83 2.59 28.9 30.6 30.5 32.3 32.2 34.2 34.1 36.1 33.9 36.0 35.9 38.1 35.6 37.8 37.7 40.0 107 99 109 100 111 102 113 103 113 103 115 105 115 104 117 106 4.19 4.70 4.33 4.87 4.48 5.04 4.64 5.21 4.63 5.20 4.79 5.38 4.77 5.35 4.93 5.54 Dividing the latent capacity by 1,069 BTU/LB of water vapor at 80°F DB and 67°F WB [26.7°C DB and 19.4°C WB] moist air enthalpy, converts the amount of moisture removal to pounds per hour (multiply pounds per hour by 0.4536 to obtain kg/hr). Note: Minimum entering air temperature ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 40 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P ClimaDry® II Option - Sequence of Operation ClimaDry® II Sequence of Operation - A heat pump equipped with ClimaDry® II can operate in three modes; cooling, cooling with reheat (dehumidification), and heating. The cooling/heating modes are like any other ClimateMaster WSHP. The reversing valve (“O” signal) is energized in cooling, along with the compressor contactor(s) and blower relay. In the heating mode the reversing valve is de-energized. Almost any thermostat will activate the heat pump in heating or cooling modes. The DXM microprocessor board, which is required with the ClimaDry® II option, will accept either heat pump (Y,O) thermostats or non-heat pump (Y,W) thermostats. The reheat mode requires either a separate humidistat/ dehumidistat or a thermostat that has an integrated dehumidification function for activation. The DXM board is configured to work with either a humidistat or dehumidistat input to terminal “H”. Upon receiving an “H” input, the DXM board will activate the cooling mode and engage reheat. Table 4 shows the relationship between thermostat input signals and unit operation.There are four operational inputs for single stage units and six operational inputs for dual stage units: -Fan Only -1st Stage Cooling -2nd Stage Cooling -1st Stage Heating -2nd Stage Heating -Reheat Mode Fan Only: A (G) call from the thermostat to the (G) terminal of the DXM control board will bring the unit on in fan only mode. 1st Stage Cooling: A simultaneous call from (G), (Y1), and (O) to the (G), (Y1), (O/W2) terminals of the DXM control board will bring the unit on in 1st Stage Cooling. 2nd Stage Cooling: A simultaneous call from (G), (Y1), (Y2), and (O) to the (G), (Y1), (Y2), and (O/W2) terminals of the DXM control board will bring the unit on in 2nd Stage Cooling. When the call is satisfied at the thermostat the unit will continue to run in 1st Stage Cooling until the 1st Stage Cooling call is removed or satisfied, shutting down the unit. NOTE: Not all units have two-stage cooling functionality. 1st Stage Heating: A simultaneous call from (G) and (Y1) to Table 2: Humidistat/Dehumidistat Logic and DXM (2.1, 2.2., 2.3) DIP Settings Sensor 2.1 2.2 2.3 Logic Reheat (ON) - H Reheat (OFF) - H Humidistat OFF OFF OFF Reverse 0 VAC 24 VAC Dehumidistat OFF ON OFF Standard 24 VAC 0 VAC Table 3: ClimaDry® II Operating Modes Input Mode Output O G Y1 Y23 H O G Y1 Y23 Reheat No Demand ON/OFF OFF OFF OFF OFF ON/OFF OFF OFF OFF OFF Fan Only ON/OFF ON OFF OFF OFF ON/OFF ON OFF OFF OFF Cooling 1st Stage ON ON ON OFF OFF ON ON ON OFF OFF ON ON ON ON OFF ON ON ON ON OFF Cooling & Dehumidistat ON ON ON ON/OFF ON ON ON ON ON/OFF OFF Dehumidistat Only ON/OFF OFF OFF OFF ON ON ON ON ON ON Heating 1st Stage OFF ON ON OFF OFF OFF ON ON OFF OFF OFF ON ON ON OFF OFF ON ON ON OFF OFF ON ON ON/OFF ON OFF ON ON ON/OFF OFF Cooling 2nd Stage 1 Heating 2nd Stage 2 Heating & Dehumidistat 1 Cooling input takes priority over dehumidify input. DXM is programmed to ignore the H demand when the unit is in heating mode. 3 N/A for single stage units; Full load operation for dual capacity units. 4 ON/OFF = Either ON or OFF. 2 ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 41 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P ClimaDry® II Option - Sequence of Operation the (G) and (Y1) terminals of the DXM control board will bring the unit on in 1st Stage Heating. 2nd Stage Heating: A simultaneous call from (G), (Y1), and (Y2) to the (G), (Y1), and (Y2) terminals of the DXM control board will bring the unit on in 2nd Stage Heating. When the call is satisfied at the thermostat the unit will continue to run in 1st Stage Heating until the call is removed or satisfied, shutting down the unit. NOTE: Not all units have two-stage heating functionality (e.g. TLV084-150 units). Reheat Mode: A call from the Humidistat/Dehumidistat to the (H) terminal of the DXM control board will bring the unit on in Reheat Mode if there is no call for cooling at the thermostat. When the Humidistat/Dehumidification call is removed or satisfied the unit will shut down. NOTE: Cooling always overrides Reheat Mode. In the Cooling mode, the unit cools and dehumidifies. If the cooling thermostat is satisfied but there is still a call for dehumidification, the unit will continue to operate in Reheat Mode. Note: Care must be taken when using a humidistat to operate ClimaDry®. When the DIP switch on the DXM controller is set for ‘humidistat’ it reverses the control logic so that an “open” control circuit initiates a ClimaDry® run cycle. If a humidistat is not connected, or if a manual switch on the humidistat is set to “off”, ClimaDry® will see the open circuit and call for dehumidification. ClimaDry® II Component Functions The ClimaDry® II option consists of the following components: Motorized Valve/Proportional Controller Supply Air Sensor Loop Pump Hydronic Coil Low Air Temperature Switch The Loop Pump circulates condenser water through the hydronic reheat coil during the reheat mode of operation. In this application, the loop pump is only energized during the reheat mode of operation. The Hydronic Coil is utilized during the reheat mode of operation to reheat the air to the setpoint of the proportional controller. Condenser water is diverted by the motorized valve and pumped through the hydronic coil by the loop pump in proportion to the control setpoint. The amount of reheating is dependent on the setpoint and how far from setpoint the supply air temperature is. The factory setpoint is 72°F [22°C], generally considered “neutral” air. ClimaDry® II Application Considerations The reheat coil adds a small amount of resistance to the air stream. In some cases the high static option may be required for applications with higher static ductwork. Consult the submittal data or the Installation/Operation/ Maintenance (I.O.M.) manual for the specific heat pump to review blower tables. Unlike most hot gas reheat options, the ClimaDry® II option will operate over a wide range of EWTs. Special flow regulation (water regulating valve) is not required for low EWT conditions. Unit minimum entering air temperature while in the dehumidification, cooling, or continuous fan modes is 65ºF DB/55ºF WB. Operation below this minimum may result in nuisance faults. Water-source heat pumps with ClimaDry® II should not be used as make-up air units. These applications should use equipment specifically designed for makeup air. The Proportional Controller operates on 24 VAC power supply and automatically adjusts the water valve based upon the Supply Air Sensor. The Supply Air Sensor senses supply air temperature at the blower inlet providing the input signal necessary for the proportional control to drive the motorized valve during the reheat mode of operation. The Motorized Valve is a proportional actuator/three-way valve combination used to divert the condenser water from the coax to the hydronic reheat coil during the reheat mode of operation. The proportional controller signals the motorized valve based on the supply air temperature of the supply air sensor. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 42 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Physical Data Model 006 009 Compressor (1 Each) 012 018 024 030 036 Rotary Factory Charge HFC-410A (oz) [kg] 042 048 060 070 Scroll 24 [0.68] 32 [0.91] 34 [0.96] 50 [1.13] 41 [1.16] 41 [1.16] 48 [1.36] 68 [1.93] 68 [1.93] 136 [3.86] 141 [4.0] N/A N/A N/A 9x7 [229 x 178] 9x7 [229 x 178] 9x7 [229 x 178] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 6X5 [152 X 127] 6X5 [152 X 127] 6X5 [152 X 127] 9x7 [229 x 178] 9x7 [229 x 178] 9x7 [229 x 178] 10 x 10 [254 x 254] 10 x 10 [254 x 254] 10 x 10 [254 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 1/2” 1/2” 1/2” 3/4” 3/4” 3/4” 3/4” 1” 1” 1” 1” N/A N/A N/A 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 0.17 [0.64] 0.29 [1.10] 0.45 [1.70] 0.56 [2.12] 0.76 [2.88] 0.76 [2.88] 0.92 [3.48] 1.24 [4.69] 1.24 [4.69] 1.56 [5.91] 1.56 [5.91] Air Coil Dimensions (h x w) (in) [mm] 16 x 16 [406 x 406] Upflow Only 16 x 16 [406 x 406] Upflow Only 16 x 16 [406 x 406] Upflow Only 24 x 20 [610 x 508] 28 x 20 [711 x 508] 28 x 20 [711 x 508] 28 x 25 [711 x 635] 32 x 25 [813 x 635] 32 x 25 [813 x 635] 36 x 25 [914 x 635] 36 x 25 [914 x 635] Standard Filter - 1” [25.4mm] Throwaway, qty (in) [mm] 16 x 20 [406 x 508] 16 x 20 [406 x 508] 16 x 20 [406 x 508] 24 x 24 [610 x 610] 28 x 24 [711 x 610] 28 x 24 [711 x 610] 28 x 30 [711 x 762] 2 - 16 x 30 [2 - 406 x 762] 2 - 16 x 30 [2 - 406 x 762] 1 - 16 x 30; 1 - 20 x 30 [1 - 406 x 762; 1 - 508 x 762] 1 - 16 x 30; 1 - 20 x 30 [1 - 406 x 762; 1 - 508 x 762] Weight - Operating, (lbs) [kg] 136 [62] 156 [71] 160 [73] 257 [117] 266 [121] 268 [122] 327 [148] 414 [188] 416 [189] 441 [200] 443 [201] Weight - Packaged, (lbs) [kg] 146 [66] 166 [75] 170 [77] 267 [121] 276 [125] 278 [126] 337 [153] 424 [192] 426 [193] 451 [205] 453 [205] Air Coil Dimensions (h x w) (in) [mm] 16 x 16 [406 x 406] 16 x 16 [406 x 406] 16 x 16 [406 x 406] 18 x 27 [457 x 686] 18 x 31 [457 x 787] 18 x 31 [457 x 787] 20 x 35 [508 x 889] 20 x 40 [508 x 1016] 20 x 40 [508 x 1016] 20 x 45 [508 x 1143] 20 x 45 [508 x 1143] Standard Filter - 1” [25.4mm] Throwaway, qty (in) [mm] 16 x 20 [406 x 508] 16 x 20 [406 x 508] 16 x 20 [406 x 508] 2 - 18 x 18 [2 - 457 x 457] 2 - 18 x 18 [2 - 457 x 457] 2 - 18 x 18 [2 - 457 x 457] 1 - 12 x 20; 1- 20 x 25 [1 - 305 x 508; 1 - 508 x 635] 1 - 18 x 20; 1 - 20 x 24 [1 - 457 x 508; 1 - 508 x 610] 1 - 18 x 20; 1 - 20 x 24 [1 - 457 x 508; 1 - 508 x 610] 2 - 20 x 24 [2 - 508 x 610] 2 - 20 x 24 [2 - 508 x 610] Weight - Operating, (lbs) [kg] 136 [62] 156 [71] 160 [73] 257 [117] 266 [121] 268 [122] 327 [148] 414 [188] 416 [189] 441 [200] 443 [201] Weight - Packaged, (lbs) [kg] 146 [66] 166 [75] 170 [77] 267 [121] 276 [125] 278 [126] 337 [153] 424 [192] 426 [193] 451 [205] 453 [205] ECM Fan Motor & Blower Blower Wheel Size (dia x w) (in) [mm] PSC Fan Motor & Blower (3 Speeds) Blower Wheel Size (dia x w) (in) [mm] Water Connection Size FPT (in) HWG Connection Size FPT (in) Coax Volume Volume (US Gallons) [liters] Vertical Upflow/Downflow Horizontal Notes: All units have TXV expansion device and 1/2” & 3/4” electrical knockouts. 575 volt motors are two speed. For units with ClimaDry® II option add 66lbs (30kg) to weights. Unit Maximum Water Working Pressure Options Max Pressure PSIG [kPa] Base Unit Internal Secondary Pump (ISP) ClimaDry ® 500 [3,447] 145 [999] 145 [999] Internal Motorized Water Valve (MWV) 300 [2,068] Internal Auto Flow Valve 300 [2,068] Use the lowest maximum pressure rating when multiple options are combined. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 43 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P TS - Horizontal – Dimensional Data Horizontal Model Overall Cabinet *A Width B Length C Height 006 012 in cm 22.4 56.8 43.1 107.8 17.3 43.1 018 in cm 22.4 56.8 62.2 158.0 19.3 48.9 024 030 in cm 22.4 56.8 62.2 158.0 19.3 48.9 036 in cm 25.4 64.5 71.2 180.8 21.3 54.0 042 048 in cm 25.4 64.5 76.2 193.5 21.3 54.0 060 070 in cm 25.4 64.5 81.2 206.2 21.3 54.0 *Does not include air filter supports. Add 2” (5.1cm) when a 1” (25.4mm) filter is used, add 3” (7.6cm) when a 2” (50.8mm) filter is used. Water Connections Units with ClimaDry® Water Connections Horizontal Model 1 2 3 4 5 Loop In D Loop Out E HWG In F HWG Out G H Water Loop FPT HWG FPT 1 2 Loop In D Loop Out E 006 012 in cm 3.7 9.3 9.7 24.2 N/A N/A 0.8 2.0 1/2” N/A N/A N/A 018 in cm 2.1 5.2 10.0 25.4 13.9 35.2 16.9 42.9 0.6 1.5 3/4” 1/2” 2.1 5.2 10.0 25.4 024 030 in cm 2.1 5.2 10.0 25.4 13.9 35.2 16.9 42.9 0.6 1.5 3/4” 1/2” 5.96 15.14 13.13 33.35 036 in cm 3.4 8.6 10.8 27.5 15.6 39.7 18.9 47.9 0.6 1.5 3/4” 1/2” 5.96 15.14 13.13 33.35 042 048 in cm 3.4 8.6 10.8 27.5 15.6 39.7 18.9 47.9 0.6 1.5 1” 1/2” 5.96 15.14 13.13 33.35 060 070 in cm 3.4 8.6 10.8 27.5 15.6 39.7 18.9 47.9 0.6 1.5 1” 1/2” 5.96 15.14 13.13 33.35 Electrical Knockouts Horizontal Model J 1/2” K 1/2” L 3/4” Low Voltage External Pump Power Supply 006 012 in cm 3.8 9.4 6.3 15.6 8.8 21.9 018 in cm 3.6 9.2 6.1 15.6 8.6 21.9 024 030 in cm 3.6 9.2 6.1 15.6 8.6 21.9 036 in cm 3.6 9.2 6.1 15.6 8.6 21.9 042 048 in cm 3.6 9.2 6.1 15.6 8.6 21.9 060 070 in cm 3.6 9.2 6.1 15.6 8.6 21.9 Notes: 1. While clear access to all removable panels is not required, installer should take care to comply with all building codes and allow adequate clearance for future field service. 2. Horizontal units shipped with filter bracket only. This bracket should be removed for return duct connection 3. Discharge flange and hanger brackets are factory installed. 4. Condensate is 3/4” NPT. 5. CCP and BSP requires 2’ service access. 6. Blower service access is through back panel on straight discharge units or through panel opposite air coil on back discharge units. Legend: CCP = Control/Compressor Access Panel BSP = Blower Service Panel *ASP = Additional Service Panel (not required) Note: *ASP are removable panels that provide additional access to the units interior. Clear access to ASP panels is not required and they are not to be used in place of the mandatory CCP and BSP panels. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 44 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P TS - Horizontal – Dimensional Data Discharge Connection Duct Flange Installed Horizontal Model M N O P Supply Supply Height Width Return Connection Using Return Air Opening Return Connection Using Optional Air Filter Frame Q R S Return Width T Return Height U V S Return Width T Return Height U V 006 - 012 in cm 5.3 13.4 4.1 10.3 9.0 22.5 9.0 22.5 5.3 13.4 4.1 10.3 17.1 43.4 15.3 38.9 2.1 5.3 1.0 2.5 17.7 45.0 14.2 36.1 2.3 5.8 1.7 4.3 018 in cm 3.6 9.3 2.0 5.1 15.5 39.4 12.5 31.8 3.6 9.2 2.0 5.2 28.1 71.4 17.3 43.9 6.2 15.7 1.0 2.5 33.8 85.8 16.2 41.0 2.3 5.8 1.7 4.3 024 - 030 in cm 3.6 9.3 2.0 5.1 15.5 39.4 12.5 31.8 3.6 9.2 2.0 5.2 32.1 81.5 17.3 43.9 2.3 5.8 1.0 2.5 33.8 85.8 16.2 41.0 2.3 5.8 1.7 4.3 036 in cm *3.1 7.9 1.2 3.1 19.0 48.3 17.5 44.5 *3.1 7.9 1.0 2.6 36.1 91.7 19.3 49.0 2.3 5.7 1.0 2.5 34.8 88.3 18.2 46.1 3.1 7.8 1.7 4.3 042 - 048 in cm 3.1 7.9 1.2 3.1 19.0 48.3 17.5 44.5 3.1 7.9 1.0 2.6 41.1 104.4 19.3 49.0 2.3 5.7 1.0 2.5 39.8 101.0 18.2 46.1 3.1 7.8 1.7 4.3 060 - 070 in cm 3.1 7.9 1.2 3.1 19.0 48.3 17.5 44.5 3.1 7.9 1.0 2.6 46.1 117.1 19.3 49.0 2.3 57 1.0 2.5 44.8 113.7 18.2 46.1 3.1 7.8 1.7 4.3 *For units with modulating reheat option this dimension is 2.9” (7.4 cm). All dimensions +/- 0.20 in. (5.1 mm). LEFT RETURN CCP ASP* Front Power Supply 3 / 4” [19.1mm] Knockout Left Return ASP* Straight Discharge 5 1.6 [40.6mm] 1.6 [40.6mm] 1 / 2” [12.7mm] Knockout 3.25 [82.6mm] 4 Low Voltage 3 1 / 2” [12.7mm] L Knockout CCP K J 2 H CCP ASP* Front Right Return ASP* 3.25 [82.6mm] G F 1 D H E Straight Discharge 5 A Front-View Condensate Back Discharge 3 / 4” NPT Note: Choose either back or straight discharge RIGHT RETURN Note: *ASP are removable panels that provide additional access to the units interior. Clear access to ASP panels is not required and they are not to be used in place of the mandatory CCP and BSP panels. Condensate 3 / 4” NPT Back Discharge BSP O Blower Outlet Y C 006-012 018-030 036 042-048 060-070 X in. 43.1 62.1 71.1 76.1 81.1 Y cm. 109.5 157.7 180.6 193.3 206.0 in. 24.5 24.5 27.5 27.5 27.5 P R Blower Outlet O Z cm. 62.2 62.2 69.9 69.9 69.9 in. 20.3 20.3 23.3 23.3 23.3 cm. 51.5 51.5 59.1 59.1 59.1 Z C Air Coil Side P Front Q Air Coil Side Unit Hanger Detail Model Note: Choose either back or straight discharge BSP Q R A A X Right Return Back Discharge Left Return Back Discharge P M Blower Outlet O N CCP ASP* BSP P BSP Blower Outlet CCP ASP* O N Front Front Right Return Straight Discharge M Left Return Straight Discharge 1.1 [27.9mm] V U S Air Coil S Air Coil ASP* C T C Front ASP* V U T Front B Left Return Left View Air Coil Opening B Right Return Right View Air Coil Opening Filter Rails Removed See Aff ---- for accessory air filter frame with duct collar ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 45 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P TS - Horizontal Service Access Right Return Back Discharge Left Return Back Discharge Supply Air Flow Supply Air Flow Air Coil Return Air Flow BSP Air Coil BSP Front Front ASP ASP ASP ASP CCP CCP Left Return Straight Discharge Right Return Straight Discharge BSP Supply Air Flow Air Coil Air Coil BSP Return Air Flow Return Air Flow Supply Air Flow Front Return Air Flow Front ASP ASP ASP ASP CCP CCP Notes: 1. While clear access to all removable panels is not required, installer should take care to comply with all building codes and allow adequate clearance for future field service. 2. CCP and BSP requires 2’ service access. 3. Blower service access is through back panel on straight discharge units or through panel opposite air coil on back discharge units. 4. ASP are removable panels that provide additional access to the units interior. Clear access to ASP panels is not required and they are not to be used in place of the mandatory CCP and BSP panels. = mandatory 2Ⱦ service access = (optional) additional 2Ⱦ service access Legend: CCP = Control/Compressor Access Panel BSP = Blower Service Panel ASP = Additional Service Panel (not required) ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 46 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P TS - Vertical Upflow – Dimensional Data Overall Cabinet Vertical Upflow Model *A Width B Depth C Height Water Connections Vertical Upflow Model 1 2 3 4 5 Loop In D Loop Out E HWG In F HWG Out G H Water Loop FPT HWG FPT 006 012 in cm 22.4 56.8 21.6 54.9 34.5 87.6 018 in cm 22.4 56.8 25.6 65.1 44.6 113.3 006 012 in cm 3.7 9.4 9.7 24.6 N/A N/A 7.4 18.7 1/2” N/A 024 030 in cm 22.4 56.8 25.6 65.1 48.5 123.2 018 in cm 2.1 5.2 10.0 25.4 13.9 35.2 16.9 42.9 7.8 19.8 3/4” 1/2” 036 in cm 25.4 64.5 30.6 77.8 50.5 128.3 024 030 in cm 2.1 5.2 10.0 25.4 13.9 35.2 16.9 42.9 7.8 19.8 3/4” 1/2” 042 048 in cm 25.4 64.5 30.6 77.8 54.5 138.4 036 in cm 3.4 8.6 10.8 27.5 15.6 39.7 18.9 47.9 7.8 19.8 3/4” 1/2” 060 070 in cm 25.4 64.5 30.6 77.8 58.5 148.6 042 048 in cm 3.4 8.6 10.8 27.5 15.6 39.7 18.9 47.9 7.8 19.8 1” 1/2” 060 070 in cm 3.4 8.6 10.8 27.5 15.6 39.7 18.9 47.9 7.8 19.8 1” 1/2” *Does not include air filter supports. Add 2” (5.1cm) when a 1” (25.4mm) filter is used, add 3” (7.6cm) when a 2” (50.8mm) filter is used. Electrical Knockouts Vertical Upflow Model J 1/2” K 1/2” L 3/4” Low Voltage External Pump Power Supply 006 012 in cm 3.8 9.5 6.3 15.9 8.8 22.2 018 in cm 3.6 9.2 6.1 15.6 8.6 21.9 024 030 in cm 3.6 9.2 6.1 15.6 8.6 21.9 036 in cm 3.6 9.2 6.1 15.6 8.6 21.9 042 048 in cm 3.6 9.2 6.1 15.6 8.6 21.9 060 070 in cm 3.6 9.2 6.1 15.6 8.6 21.9 Notes: 1. While clear access to all removable panels is not required, installer should take care to comply with all building codes and allow adequate clearance for future field service. 2. Front & Side access is preferred for service access. However, all components may be serviced from the front access panel if side access is not available. 3. Discharge flange is field installed. 4. Condensate is 3/4” NPT. Legend: CCP = Control/Compressor Access Panel BSP = Blower Service Panel ASP = Additional Service Panel (not required) ‡ Recommended Minimum Installation Clearances for Vertical Units* 1” † Back of unit 1” Side opposite return air Front if hard piped 1” Return Air Side Ducted return 1” Air Coil Side 6” 1” - ‡ Add for duct width - † Add 2” for 1” filter frame/rail or 3” for 2” filter frame/rail Front Free (open) return - calculate required dimension for a maximum velocity of 600 fpm 6” *Field installed accessories (hoses, air cleaners, etc.) may require additional space. Top supply air is shown, the same clearances apply to bottom supply air units. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 47 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P TS - Vertical Upflow – Dimensional Data Discharge Connection Duct Flange Installed Vertical Upflow Model Return Connection Using Return Air Opening Return Connection Using Optional Air Filter Frame M N O Supply Width P Supply Depth Q R S Return Depth T Return Height U R S Return Depth T Return Height U 006 012 in cm 6.7 17.0 6.3 16.0 9.0 22.9 9.0 22.9 6.7 17.0 2.3 5.8 17.1 43.3 15.3 38.9 1.0 2.5 1.7 4.3 17.7 45.0 14.2 36.1 1.7 4.3 018 in cm 7.2 18.3 5.8 14.8 14.0 35.6 14.0 35.6 4.9 12.4 2.3 5.8 21.1 53.6 23.7 60.2 1.0 2.5 1.7 4.3 22.2 56.4 22.2 66.5 1.7 4.3 024 030 in cm 7.2 18.3 5.8 14.8 14.0 35.6 14.0 35.6 4.9 12.4 2.3 5.8 21.1 53.6 27.7 70.4 1.0 2.5 1.7 4.3 22.2 56.4 26.2 66.5 1.7 4.3 036 in cm 6.4 16.1 6.3 16.0 18.0 45.7 18.0 45.7 5.3 13.5 2.3 5.8 26.1 66.3 27.7 70.4 1.0 2.5 1.7 4.3 27.2 69.1 26.2 66.5 1.7 4.3 042 048 in cm 6.4 16.1 6.3 16.0 18.0 45.7 18.0 45.7 5.3 13.5 2.3 5.8 26.1 66.3 30.5 77.5 1.0 2.5 1.7 4.3 27.2 69.1 30.2 76.7 1.7 4.3 060 070 in cm 6.4 16.1 6.3 16.0 18.0 45.7 18.0 45.7 5.3 13.5 2.3 5.8 26.1 66.3 35.7 90.7 1.0 2.5 1.7 4.3 27.2 69.1 34.2 86.9 1.7 4.3 All dimensions +/- .20 in, (+/- 5.1mm). Field Installed Discharge Flange Filter Rails Air Coil N N P BSP Front O B Front P ASP* O A ASP* Q Air Coil Side Air Coil Side Top View-Right Return Top View-Left Return S R R U CCP M S Isometric (Left Return) View 1.00 [25.4 mm] U Air Coil Air Coil T T 1.68 [42.7 mm] C C 1.18 [30.0 mm] ASP* Condensate 3/4" FPT Power Supply 3 / 4" [19.1mm] HV Knockout 1 / 2" [12.7mm] Knockout Low Voltage 1 / 2" [12.7mm] LV Knockout ASP* 1.63 [41.4 mm] Back Right Return Right View - Air Coil Opening Back Front Left Return Left View - Air Coil Opening 4 3 2 ASP* Front CCP H J K L F 5 1 D H G E Front-View Note: *ASP are removable panels that provide additional access to the units interior. Clear access to ASP panels is not required and they are not to be used in place of the mandatory CCP and BSP panels. Filter Rails Removed See Aff ---- for accessory air filter frame with duct collar ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 48 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P TS - Vertical Service Access Vertical Units Left Return Air Coil Supply Air Opening Front ASP ASP CCP and BSP Right Return Air Coil Supply Air Opening Front ASP ASP CCP and BSP Notes: 1. While clear access to all removable panels is not required, installer should take care to comply with all building codes and allow adequate clearance for future field service. 2. Front & Side access is preferred for service access. However, all components may be serviced from the front access panel if side access is not available. 3. ASP are removable panels that provide additional access to the units interior. Clear access to ASP panels is not required and they are not to be used in place of the mandatory CCP and BSP panels. 4. Top supply air is shown, the same clearances apply to bottom supply air units. = mandatory 2Ⱦ service access = (optional) additional 2Ⱦ service access Legend: CCP = Control/Compressor Access Panel BSP = Blower Service Panel ASP = Additional Service Panel (not required) ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 49 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P TS - Vertical Downflow – Dimensional Data Vertical Downflow Model Electrical Knockouts Overall Cabinet *A Width B Depth C Height Vertical Downflow Model J 1/2” K 1/2” L 3/4” Low Voltage External Pump Power Supply 018 in cm 22.4 56.8 25.6 65.1 48.4 122.9 024 030 in cm 22.4 56.8 25.6 65.1 52.5 133.4 018 in cm 3.6 9.2 6.1 15.6 8.6 21.9 036 in cm 25.4 64.5 30.6 77.8 54.5 138.4 024 030 in cm 3.6 9.2 6.1 15.6 8.6 21.9 042 048 in cm 25.4 64.5 30.6 77.8 58.5 148.6 036 in cm 3.6 9.2 6.1 15.6 8.6 21.9 060 070 in cm 25.4 64.5 30.6 77.8 62.5 158.8 042 048 in cm 3.6 9.2 6.1 15.6 8.6 21.9 060 070 in cm 3.6 9.2 6.1 15.6 8.6 21.9 *Does not include air filter supports. Add 2” (5.1cm) when a 1” (25.4mm) filter is used, add 3” (7.6cm) when a 2” (50.8mm) filter is used. Water Connections Vertical Downflow Model 1 2 3 4 5 Loop In D Loop Out E HWG In F HWG Out G H Water Loop FPT HWG FPT 018 in cm 17.2 43.7 9.3 23.6 5.4 13.7 2.4 6.1 3.6 9.2 3/4” 1/2” 024 030 in cm 17.9 45.5 10.5 26.7 5.7 14.5 2.4 6.1 3.6 9.2 3/4” 1/2” 036 in cm 17.9 45.5 10.5 26.7 5.7 14.5 2.4 6.1 3.6 9.2 3/4” 1/2” 042 048 in cm 17.9 45.5 10.5 26.7 5.7 14.5 2.4 6.1 3.6 9.2 1” 1/2” 060 070 in cm 17.9 45.5 10.5 26.7 5.7 14.5 2.4 6.1 3.6 9.2 1” 1/2” Recommended Minimum Installation Clearances for Vertical Units* ‡ 1” † Back of unit 1” Side opposite return air Front if hard piped 1” Return Air Side Air Coil Side 6” 1” Ducted return 1” - ‡ Add for duct width Front - † Add 2” for 1” filter frame/rail or 3” for 2” filter frame/rail Free (open) return - calculate required dimension for a maximum velocity of 600 fpm 6” *Field installed accessories (hoses, air cleaners, etc.) may require additional space. Top supply air is shown, the same clearances apply to bottom supply air units. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 50 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P TS - Vertical Downflow – Dimensional Data Discharge Connection Duct Flange Installed Vertical Downflow Model Return Connection Using Return Air Opening Return Connection Using Optional Air Filter Frame M N O Supply Width P Supply Depth Q R S Return Depth T Return Height U R S Return Depth T Return Height U 018 in cm 6.7 17.1 8.4 21.4 10.1 25.7 9.1 23.0 10.8 27.4 2.2 5.6 21.1 53.6 23.7 60.2 21.2 53.8 1.7 4.3 22.2 56.4 22.2 56.4 21.9 55.6 024 030 in cm 6.7 17.1 8.4 21.4 10.1 25.7 9.1 23.0 10.8 27.4 2.2 5.6 21.1 53.6 27.7 70.4 21.2 53.8 1.7 4.3 22.2 56.4 26.2 66.5 21.9 55.6 036 in cm 7.2 18.3 9.0 22.9 13.4 34.0 12.9 32.7 10.4 26.5 2.2 5.6 26.1 66.3 27.7 70.4 23.2 58.9 1.7 4.3 27.2 69.1 26.2 66.5 23.9 60.7 042 048 in cm 7.2 18.3 9.0 22.9 13.4 34.0 12.9 32.7 10.4 26.5 2.2 5.6 26.1 66.3 30.5 77.5 23.2 58.9 1.7 4.3 27.2 69.1 30.2 76.7 23.9 60.7 060 070 in cm 7.2 18.3 9.0 22.9 13.4 34.0 12.9 32.7 10.4 26.5 2.2 5.6 26.1 66.3 35.7 90.7 23.2 58.9 1.7 4.3 27.2 69.1 34.2 86.9 23.9 60.7 All dimensions +/- .20 in, (+/- 5.1mm). Legend: CCP = Control/Compressor Access Panel BSP = Blower Service Panel ASP = Additional Service Panel (not required) P Filter Rail ASP* N N ASP* CCP ASP* P O Blower Opening O A Front A Blower Opening BSP Front Condensate 3/4” Q FPT M Air Coil Side Air Coil Side B B Left Return Discharge Floor Foot Print Right Return Discharge Floor Foot Print 1.1 [27.9mm] ASP* U ASP* U Isometric View (Right Return) Power Supply 3 / 4” [19.1mm] HV Knockout 1.6 [40.6mm] 1 / 2” [12.7mm] Knockout L Low Voltage 1 / 2” [12.7mm] LV Knockout K 1.6 [40.6mm] 4 J CCP 3 2 G F E D 1 Air Coil T Air Coil C BSP Condensate 3 / 4” FPT Right Return T Condensate 3 / 4” FPT Left Return Front Back Back S R Right Return Right View - Air Coil Opening Front R Filter Rails Removed See Aff ---- for accessory air filter frame with duct collar 5 Front-View S Left Return Left View - Air Coil Opening 5 H Notes: 1. While clear access to all removable panels is not required, installer should take care to comply with all building codes and allow adequate clearance for future field service. 2. Front & Side access is preferred for service access. However, all components may be serviced from the front access panel if side access is not available. 3. Condensate is 3/4” FPT PVC. 4. ASP are removable panels that provide additional access to the units interior. Clear access to ASP panels is not required and they are not to be used in place of the mandatory CCP and BSP panels. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 51 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Corner Weights for TSH Series Units Model 006 009 012 018 024 030 036 042 048 060 070 Lbs Total Left-Front* Right-Front* Left-Back* Right-Back* 136 45.0 30.0 33.0 28.0 kg 62 20.4 13.6 15.0 12.7 Lbs 156 55.0 33.0 36.0 32.0 kg 71 24.9 15.0 16.3 14.5 Lbs 160 56.0 34.0 37.0 33.0 kg 73 25.4 15.4 16.8 15.0 Lbs 257 78.1 64.6 66.2 47.5 kg 117 35.4 29.3 30.0 21.6 Lbs 266 78.8 67.2 69.9 50.2 kg 122 35.7 30.5 31.7 22.7 Lbs 268 79.4 67.7 70.4 50.5 kg 122 36.0 30.7 31.9 22.9 Lbs 327 104.4 74.9 83.7 64.0 kg 148 47.4 34.0 38.0 29.0 Lbs 414 144.3 92.1 97.7 79.9 kg 188 65.4 41.8 44.3 36.2 Lbs 416 145.0 92.6 98.1 80.3 kg 189 65.8 42.0 44.5 36.4 Lbs 441 182.3 72.5 78.4 107.8 kg 200 82.7 32.9 35.6 48.9 Lbs 443 183.1 72.8 78.8 108.3 kg 201 83.1 33.0 35.7 49.1 *Front is control box end. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 52 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Electrical Data – PSC Motor & ClimaDry® All TS Units with Standard PSC Motor Model 018 024 030 036 042 048 060 070 Compressor Voltage Code Rated Voltage Voltage Min/Max G 208/230/60/1 197/254 1 E 265/60/1 239/292 1 G 208/230/60/1 197/254 1 TS Units with PSC Fan Motor and ClimaDry® TS Units (PSC) LRA Fan Motor FLA Total Unit FLA Min Circuit Amp Max Fuse/ HACR Reheat Pump FLA Total Unit FLA Min Circuit Amp Max Fuse/ HACR 9.0 48.0 1.0 10.0 12.3 20 0.8 10.8 13.1 20 8.4 40.0 0.9 9.3 11.4 15 0.7 10.0 12.1 20 13.5 58.3 1.6 15.1 18.5 30 0.8 15.9 19.3 30 QTY RLA E 265/60/1 239/292 1 9 54.0 1.1 10.1 12.4 20 0.7 10.8 13.1 20 H 208/230/60/3 197/254 1 7.1 55.4 1.6 8.7 10.5 15 0.8 9.5 11.3 15 F* 460/60/3* 414/506 1 3.5 28.0 0.9 4.4 5.3 15 0.7 5.1 6.0 15 G 208/230/60/1 197/254 1 12.8 64.0 1.8 14.6 17.8 30 0.8 15.4 18.6 30 E 265/60/1 239/292 1 10.9 60.0 1.4 12.3 15.0 25 0.7 13.0 15.7 25 H 208/230/60/3 197/254 1 8.3 58.0 1.8 10.1 12.2 20 0.8 10.9 13.0 20 F* 460/60/3* 414/506 1 5.1 28.0 1.0 6.1 7.4 15 0.7 6.8 8.1 15 G 208/230/60/1 197/254 1 16.0 77.0 1.8 17.8 21.8 35 0.8 18.6 22.6 35 E 265/60/1 239/292 1 12.2 72.0 2.0 14.2 17.3 25 0.7 14.9 18.0 30 H 208/230/60/3 197/254 1 10 71.0 1.8 11.8 14.3 20 0.8 12.6 15.1 25 F* 460/60/3* 414/506 1 4.7 38.0 1.0 5.7 6.9 15 0.7 6.4 7.6 15 G 208/230/60/1 197/254 1 16.7 79.0 2.2 18.9 23.1 35 0.8 19.7 23.9 40 E 265/60/1 239/292 1 13.5 72.0 1.7 15.2 18.6 30 0.7 15.9 19.3 30 H 208/230/60/3 197/254 1 10.4 73.0 2.2 12.6 15.2 25 0.8 13.4 16.0 25 F* 460/60/3* 414/506 1 5.8 38.0 1.0 6.8 8.3 15 0.7 7.5 9.0 15 N 575/60/3 518/633 1 3.8 36.5 0.8 4.6 5.6 15 N/A N/A N/A N/A G 208/230/60/1 197/254 1 21.8 117.0 2.7 24.5 30.0 50 1.1 25.6 31.0 50 E 265/60/1 239/292 1 16.3 98.0 2.9 19.2 23.3 35 1.3 20.5 24.6 40 30 H 208/230/60/3 197/254 1 13.7 83.1 2.7 16.4 19.8 30 1.1 17.5 20.9 F* 460/60/3* 414/506 1 6.2 41.0 1.7 7.9 9.5 15 1.3 9.0 10.6 15 N 575/60/3 518/633 1 4.8 33.0 1.4 6.2 7.4 15 N/A N/A N/A N/A G 208/230/60/1 197/254 1 26.4 134.0 3.8 30.2 36.8 60 1.1 31.3 37.9 60 H 208/230/60/3 197/254 1 16 110.0 3.8 19.8 23.8 35 1.1 20.9 24.9 40 F* 460/60/3* 414/506 1 7.8 52.0 1.3 9.1 11.1 15 1.3 10.4 12.4 20 N 575/60/3 518/633 1 5.7 38.9 2.2 7.9 9.3 15 N/A N/A N/A N/A G 208/230/60/1 197/254 1 30.8 178.0 4.0 34.8 42.5 70 1.1 35.9 43.6 70 H 208/230/60/3 197/254 1 19.6 138.0 4.0 23.6 28.5 45 1.1 24.7 29.6 45 F* 460/60/3* 414/506 1 8.2 66.1 2.6 10.8 12.9 20 1.3 12.1 14.2 20 N 575/60/3 518/633 1 6.6 55.3 1.5 8.1 9.8 15 N/A N/A N/A N/A * NEUTRAL CONNECTION REQUIRED! All F Voltage (460 vac) units with ClimaDry® require a four wire power supply with neutral. Reheat pump is rated 265 vac and is wired between one hot leg and neutral. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 53 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Electrical Data – High Static PSC Motor & ClimaDry® All TS Units with High Static PSC Fan Motor Model 018 024 030 036 042 048 060 TS (H.S. PSC) Units TS Units with H.S. PSC Fan Motor and ClimaDry® LRA Fan Motor FLA Total Unit FLA Min Circuit Amp Max Fuse/ HACR Reheat Pump FLA Total Unit FLA Min Circuit Amp Max Fuse/ HACR 9.0 48.0 1.1 10.1 12.4 20 0.8 10.9 13.2 20 8.4 40.0 0.9 9.3 11.4 15 0.7 10.0 12.1 20 13.5 58.3 1.8 15.3 18.7 30 0.8 16.1 19.5 30 Compressor Voltage Code Rated Voltage Voltage Min/Max QTY RLA G 208/230/60/1 197/254 1 E 265/60/1 239/292 1 G 208/230/60/1 197/254 1 E 265/60/1 239/292 1 9 54.0 1.4 10.4 12.7 20 0.7 11.1 13.4 20 H 208/230/60/3 197/254 1 7.1 55.4 1.8 8.9 10.7 15 0.8 9.7 11.5 15 F* 460/60/3* 414/506 1 3.5 28.0 1 4.5 5.4 15 0.7 5.2 6.1 15 G 208/230/60/1 197/254 1 12.8 64.0 2.2 15.0 18.2 30 0.8 15.8 19.0 30 E 265/60/1 239/292 1 10.9 60.0 1.7 12.6 15.3 25 0.7 13.3 16.0 25 H 208/230/60/3 197/254 1 8.3 58.0 2.2 10.5 12.6 20 0.8 11.3 13.4 20 F* 460/60/3* 414/506 1 5.1 28.0 1.0 6.1 7.4 15 0.7 6.8 8.1 15 G 208/230/60/1 197/254 1 16.0 77.0 2.2 18.2 22.2 35 0.8 19.0 23.0 35 E 265/60/1 239/292 1 12.2 72.0 1.7 13.9 17.0 25 0.7 14.6 17.7 25 25 H 208/230/60/3 197/254 1 10 71.0 2.2 12.2 14.7 25 0.8 13.0 15.5 F* 460/60/3* 414/506 1 4.7 38.0 1.0 5.7 6.9 15 0.7 6.4 7.6 15 G 208/230/60/1 197/254 1 16.7 79.0 2.7 19.4 23.6 35 0.8 20.2 24.4 40 E 265/60/1 239/292 1 13.5 72.0 2.9 16.4 19.8 30 0.7 17.1 20.5 30 H 208/230/60/3 197/254 1 10.4 73.0 2.7 13.1 15.7 25 0.8 13.9 16.5 25 F* 460/60/3* 414/506 1 5.8 38.0 1.7 7.5 9.0 15 0.7 8.2 9.7 15 N 575/60/3 518/633 1 3.8 36.5 1.4 5.2 6.2 15 N/A N/A N/A N/A G 208/230/60/1 197/254 1 21.8 117.0 2.6 24.4 29.9 50 1.1 25.5 31.0 50 H 208/230/60/3 197/254 1 13.7 83.1 2.6 16.3 19.7 30 1.1 17.4 20.8 30 F* 460/60/3* 414/506 1 6.2 41.0 1.8 8.0 9.6 15 1.3 9.3 10.9 15 N 575/60/3 518/633 1 4.8 33.0 1.4 6.2 7.4 15 N/A N/A N/A N/A G 208/230/60/1 197/254 1 26.4 134.0 4.0 30.4 37.0 60 1.1 31.5 38.1 60 40 H 208/230/60/3 197/254 1 16 110.0 4.0 20.0 24.0 35 1.1 21.1 25.1 F* 460/60/3* 414/506 1 7.8 52.0 2.6 10.4 12.4 15 1.3 11.7 13.7 20 N 575/60/3 518/633 1 5.7 38.9 1.5 7.2 8.6 15 N/A N/A N/A N/A * NEUTRAL CONNECTION REQUIRED! All F Voltage (460 vac) units with ClimaDry® require a four wire power supply with neutral. Reheat pump is rated 265 vac and is wired between one hot leg and neutral. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 54 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Electrical Data – ECM Motor & ClimaDry® All TS Units with ECM Fan Motor Model 018 024 030 036 042 048 060 070 TS Units with ECM Fan Motor and ClimaDry® TS Units (ECM) LRA Fan Motor FLA Total Unit FLA Min Circuit Amp Max Fuse/ HACR Reheat Pump FLA Total Unit FLA Min Circuit Amp Max Fuse/ HACR 9.0 48.0 3.9 12.9 15.2 20 0.8 13.7 16.0 20 8.4 40.0 3.2 11.6 13.7 20 0.7 12.3 14.4 20 13.5 58.3 3.9 17.4 20.8 30 0.8 18.2 21.6 35 Compressor Voltage Code Rated Voltage Voltage Min/Max QTY RLA G 208/230/60/1 197/254 1 E 265/60/1 239/292 1 G 208/230/60/1 197/254 1 E 265/60/1 239/292 1 9 54.0 3.2 12.2 14.5 20 0.7 12.9 15.2 20 H 208/230/60/3 197/254 1 7.1 55.4 3.9 11.0 12.8 15 0.8 11.8 13.6 20 F* 460/60/3* 414/506 1 3.5 28.0 3.2 6.7 7.6 15 0.7 7.4 8.3 15 G 208/230/60/1 197/254 1 12.8 64.0 3.9 16.7 19.9 30 0.8 17.5 20.7 30 E 265/60/1 239/292 1 10.9 60.0 3.2 14.1 16.8 25 0.7 14.8 17.5 25 H 208/230/60/3 197/254 1 8.3 58.0 3.9 12.2 14.3 20 0.8 13.0 15.1 20 F* 460/60/3* 414/506 1 5.1 28.0 3.2 8.3 9.6 15 0.7 9.0 10.3 15 G 208/230/60/1 197/254 1 16.0 77.0 3.9 19.9 23.9 35 0.8 20.7 24.7 40 E 265/60/1 239/292 1 12.2 72.0 3.2 15.4 18.5 30 0.7 16.1 19.2 30 H 208/230/60/3 197/254 1 10 71.0 3.9 13.9 16.4 25 0.8 14.7 17.2 25 F* 460/60/3* 414/506 1 4.7 38.0 3.2 7.9 9.1 15 0.7 8.6 9.8 15 G 208/230/60/1 197/254 1 16.7 79. 3.9 20.6 24.8 40 0.8 21.4 25.6 40 E 265/60/1 239/292 1 13.5 72.0 3.2 16.7 20.1 30 0.7 17.4 20.8 30 H 208/230/60/3 197/254 1 10.4 73.0 3.9 14.3 16.9 25 0.8 15.1 17.7 25 F* 460/60/3* 414/506 1 5.8 38.0 3.2 9.0 10.5 15 0.7 9.7 11.2 15 G 208/230/60/1 197/254 1 21.8 117.0 6.9 28.7 34.2 50 1.1 29.8 35.3 50 E 265/60/1 239/292 1 16.3 98.0 6.0 22.3 26.4 40 1.3 23.6 27.7 40 H 208/230/60/3 197/254 1 13.7 83.1 6.9 20.6 24.0 35 1.1 21.7 25.1 35 F* 460/60/3* 414/506 1 6.2 41.0 6.0 12.2 13.8 20 1.3 13.5 15.1 20 G 208/230/60/1 197/254 1 26.4 134.0 6.9 33.3 39.9 60 1.1 34.4 41.0 60 E 265/60/1 239/292 1 19.9 130.0 6.0 25.9 30.9 50 1.3 27.2 32.2 50 H 208/230/60/3 197/254 1 16 110.0 6.9 22.9 26.9 40 1.1 24.0 28.0 40 F* 460/60/3* 414/506 1 7.8 52.0 6.0 13.8 15.8 20 1.3 15.1 17.1 20 G 208/230/60/1 197/254 1 30.8 178.0 6.9 37.7 45.4 70 1.1 37.9 45.6 70 H 208/230/60/3 197/254 1 19.6 138.0 6.9 26.5 31.4 50 1.1 27.6 32.5 50 F* 460/60/3* 414/506 1 8.2 66.1 6.0 14.2 16.3 20 1.3 15.5 17.6 25 ® * NEUTRAL CONNECTION REQUIRED! All F Voltage (460 vac) units with ECM motors/ClimaDry require a four wire power supply with neutral. ECM motors/reheat pumps are rated 265 vac and are wired between one hot leg and neutral. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 55 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Electrical Data – PSC Motor & Secondary Pump All TS Units with Standard PSC Motor Model 006 009 012 018 024 030 036 042 048 060 070 Voltage Code Rated Voltage Voltage Min/ Max QTY RLA G 208/230/60/1 197/254 1 3.1 TS Units with PSC Fan Motor and Secondary Pump TS Units (PSC) LRA Fan Motor FLA Total Unit FLA Min Circuit Amp Max Fuse/ HACR Pump FLA Total Unit FLA Min Circuit Amp Max Fuse/ HACR 17.7 0.4 3.5 4.3 15 0.4 3.9 4.7 15 Compressor E 265/60/1 239/292 1 2.6 13.5 0.4 3.0 3.6 15 0.7 3.7 4.3 15 G 208/230/60/1 197/254 1 3.9 21.0 0.4 4.3 5.3 15 0.4 4.7 5.7 15 E 265/60/1 239/292 1 3.7 22.0 0.4 4.1 5.0 15 0.7 4.8 5.7 15 G 208/230/60/1 197/254 1 5.0 25.0 0.7 5.7 7.0 15 0.4 6.1 7.4 15 E 265/60/1 239/292 1 4.5 22.0 0.7 5.2 6.4 15 0.7 5.9 7.0 15 G 208/230/60/1 197/254 1 9.0 48.0 1.0 10.0 12.3 20 0.4 10.4 12.7 20 E 265/60/1 239/292 1 8.4 40.0 0.9 9.3 11.4 15 0.7 10.0 12.1 20 G 208/230/60/1 197/254 1 13.5 58.3 1.6 15.1 18.5 30 0.4 15.5 18.9 30 E 265/60/1 239/292 1 9 54.0 1.1 10.1 12.4 20 0.7 10.8 13.1 20 H 208/230/60/3 197/254 1 7.1 55.4 1.6 8.7 10.5 15 0.4 9.13 10.9 15 F* 460/60/3* 414/506 1 3.5 28.0 0.9 4.4 5.3 15 0.7 5.1 6.0 15 G 208/230/60/1 197/254 1 12.8 64.0 1.8 14.6 17.8 30 0.8 15.4 18.6 30 E 265/60/1 239/292 1 10.9 60.0 1.4 12.3 15.0 25 0.7 13.0 15.7 25 H 208/230/60/3 197/254 1 8.3 58.0 1.8 10.1 12.2 20 0.8 10.9 13.0 20 F* 460/60/3* 414/506 1 5.1 28.0 1.0 6.1 7.4 15 0.7 6.8 8.1 15 G 208/230/60/1 197/254 1 16.0 77.0 1.8 17.8 21.8 35 0.8 18.6 22.6 35 E 265/60/1 239/292 1 12.2 72.0 2.0 14.2 17.3 25 0.7 14.9 18.0 30 H 208/230/60/3 197/254 1 10 71.0 1.8 11.8 14.3 20 0.8 12.6 15.1 25 F* 460/60/3* 414/506 1 4.7 38.0 1.0 5.7 6.9 15 0.7 6.4 7.6 15 G 208/230/60/1 197/254 1 16.7 79.0 2.2 18.9 23.1 35 0.8 19.7 23.9 40 E 265/60/1 239/292 1 13.5 72.0 1.7 15.2 18.6 30 0.7 15.9 19.3 30 H 208/230/60/3 197/254 1 10.4 73.0 2.2 12.6 15.2 25 0.8 13.4 16.0 25 F* 460/60/3* 414/506 1 5.8 38.0 1.0 6.8 8.3 15 0.7 7.5 9.0 15 N 575/60/3 518/633 1 3.8 36.5 0.8 4.6 5.6 15 N/A N/A N/A N/A G 208/230/60/1 197/254 1 21.8 117.0 2.7 24.5 30.0 50 0.8 25.3 30.8 50 E 265/60/1 239/292 1 16.3 98.0 2.9 19.2 23.3 35 0.7 19.9 24.0 40 H 208/230/60/3 197/254 1 13.7 83.1 2.7 16.4 19.8 30 0.8 17.2 20.6 30 F* 460/60/3* 414/506 1 6.2 41.0 1.7 7.9 9.5 15 0.7 8.6 10.2 15 N 575/60/3 518/633 1 4.8 33.0 1.4 6.2 7.4 15 N/A N/A N/A N/A G 208/230/60/1 197/254 1 26.4 134.0 3.8 30.2 36.8 60 1.1 31.3 37.9 60 40 H 208/230/60/3 197/254 1 16 110.0 3.8 19.8 23.8 35 1.1 20.9 24.9 F* 460/60/3* 414/506 1 7.8 52.0 1.3 9.1 11.1 15 1.3 10.4 12.4 20 N 575/60/3 518/633 1 5.7 38.9 2.2 7.9 9.3 15 N/A N/A N/A N/A G 208/230/60/1 197/254 1 30.8 178.0 4.0 34.8 42.5 70 1.1 35.9 43.6 70 45 H 208/230/60/3 197/254 1 19.6 138.0 4.0 23.6 28.5 45 1.1 24.7 29.6 F* 460/60/3* 414/506 1 8.2 66.1 2.6 10.8 12.9 20 1.3 12.1 14.2 20 N 575/60/3 518/633 1 6.6 55.3 1.5 8.1 9.8 15 N/A N/A N/A N/A * NEUTRAL CONNECTION REQUIRED! All F Voltage (460 vac) units with internal secondary circulators require a four wire power supply with neutral. Internal secondary circulators are rated 265 vac and are wired between one hot leg and neutral. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 56 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Electrical Data – High Static PSC Motor & Secondary Pump All TS Units with High Static PSC Fan Motor Model 018 024 030 036 042 048 060 Voltage Code Rated Voltage Voltage Min/ Max QTY RLA G 208/230/60/1 197/254 1 E 265/60/1 239/292 1 G 208/230/60/1 197/254 1 TS (H.S. PSC) Units TS Units with H.S. PSC Fan Motor and Secondary Pump LRA Fan Motor FLA Total Unit FLA Min Circuit Amp Max Fuse/ HACR Pump FLA Total Unit FLA Min Circuit Amp Max Fuse/ HACR 9.0 48.0 1.1 10.1 12.4 20 0.4 10.5 12.8 20 8.4 40.0 0.9 9.3 11.4 15 0.7 10.0 12.1 20 13.5 58.3 1.8 15.3 18.7 30 0.4 15.7 19.1 30 Compressor E 265/60/1 239/262 1 9 54.0 1.4 10.4 12.7 20 0.7 11.1 13.4 20 H 208/230/60/3 197/254 1 7.1 55.4 1.8 8.9 10.7 15 0.4 9.3 11.1 15 F* 460/60/3* 414/506 1 3.5 28.0 1 4.5 5.4 15 0.7 5.2 6.1 15 G 208/230/60/1 197/254 1 12.8 64.0 2.2 15.0 18.2 30 0.8 15.8 19.0 30 E 265/60/1 239/292 1 10.9 60.0 1.7 12.6 15.3 25 0.7 13.3 16.0 25 H 208/230/60/3 197/254 1 8.3 58.0 2.2 10.5 12.6 20 0.8 11.3 13.4 20 F* 460/60/3* 414/506 1 5.1 28.0 1.0 6.1 7.4 15 0.7 6.8 8.1 15 G 208/230/60/1 197/254 1 16.0 77.0 2.2 18.2 22.2 35 0.8 19.0 23.0 35 E 265/60/1 239/292 1 12.2 72.0 1.7 13.9 29.2 25 0.7 14.6 17.7 25 H 208/230/60/3 197/254 1 10 71.0 2.2 12.2 14.7 25 0.8 13.0 15.5 25 F* 460/60/3* 414/506 1 4.7 38.0 1.0 5.7 6.9 15 0.7 6.4 7.6 15 G 208/230/60/1 197/254 1 16.7 79.0 2.7 19.4 23.6 35 0.8 20.2 24.4 40 E 265/60/1 239/292 1 13.5 72.0 2.9 16.4 19.8 30 0.7 17.1 20.5 30 H 208/230/60/3 197/254 1 10.4 73.0 2.7 13.1 15.7 25 0.8 13.9 16.5 25 F* 460/60/3* 414/506 1 5.8 38.0 1.7 7.5 9.0 15 0.7 8.2 9.7 15 N 575/60/3 518/633 1 3.8 36.5 1.4 5.2 6.2 15 N/A N/A N/A N/A G 208/230/60/1 197/254 1 21.8 117.0 2.6 24.4 29.9 50 0.8 25.2 30.7 50 H 208/230/60/3 197/254 1 13.7 83.1 2.6 16.3 19.7 30 0.8 17.1 20.5 30 F* 460/60/3* 414/506 1 6.2 41.0 1.8 8.0 9.6 15 0.7 8.7 10.3 15 N/A N 575/60/3 518/633 1 4.8 33.0 1.4 6.2 7.4 15 N/A N/A N/A G 208/230/60/1 197/254 1 26.4 134.0 4.0 30.4 37.0 60 1.1 31.5 38.1 60 H 208/230/60/3 197/254 1 16 110.0 4.0 20.0 24.0 35 1.1 21.1 25.1 40 F* 460/60/3* 414/506 1 7.8 52.0 2.6 10.4 12.4 15 1.3 11.7 13.7 20 N 575/60/3 518/633 1 5.7 38.9 1.5 7.2 8.6 15 N/A N/A N/A N/A * NEUTRAL CONNECTION REQUIRED! All F Voltage (460 vac) units with internal secondary circulators require a four wire power supply with neutral. Internal secondary circulators are rated 265 vac and are wired between one hot leg and neutral. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 57 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Electrical Data – ECM Motor & Secondary Pump All TS Units with ECM Fan Motor Model 018 024 030 036 042 048 060 070 TS Units (ECM) TS Units with ECM Fan Motor and Secondary Pump LRA Fan Motor FLA Total Unit FLA Min Circuit Amp Max Fuse/ HACR Pump FLA Total Unit FLA Min Circuit Amp Max Fuse/ HACR 9.0 48.0 3.9 12.9 15.2 20 0.4 13.3 15.6 20 8.4 40.0 3.2 11.6 13.7 20 0.7 12.3 14.4 20 13.5 58.3 3.9 17.4 20.8 30 0.4 17.8 21.2 30 Compressor Voltage Code Rated Voltage Voltage Min/Max QTY RLA G 208/230/60/1 197/254 1 E 265/60/1 239/292 1 G 208/230/60/1 197/254 1 E 265/60/1 239/292 1 9 54.0 3.2 12.2 14.5 20 0.7 12.9 15.2 20 H 208/230/60/3 197/254 1 7.1 55.4 3.9 11.0 12.8 15 0.4 11.4 13.2 20 F* 460/60/3* 414/506 1 3.5 28.0 3.2 6.7 7.6 15 0.7 7.4 8.3 15 G 208/230/60/1 197/254 1 12.8 64.0 3.9 16.7 19.9 30 0.8 17.5 20.7 30 E 265/60/1 239/292 1 10.9 60.0 3.2 14.1 16.8 25 0.7 14.8 17.5 25 H 208/230/60/3 197/254 1 8.3 58.0 3.9 12.2 14.3 20 0.8 13.0 15.1 20 F* 460/60/3* 414/506 1 5.1 28.0 3.2 8.3 9.6 15 0.7 9.0 10.3 15 G 208/230/60/1 197/254 1 16.0 77.0 3.9 19.9 23.9 35 0.8 20.7 24.7 40 E 265/60/1 239/292 1 12.2 72.0 3.2 15.4 30.7 30 0.7 16.1 19.2 30 H 208/230/60/3 197/254 1 10 71.0 3.9 13.9 16.4 25 0.8 14.7 17.2 25 F* 460/60/3* 414/506 1 4.7 38.0 3.2 7.9 9.1 15 0.7 8.6 9.8 15 G 208/230/60/1 197/254 1 16.7 79.0 3.9 20.6 24.8 40 0.8 21.4 25.6 40 E 265/60/1 239/292 1 13.5 72.0 3.2 16.7 20.1 30 0.7 17.4 20.8 30 H 208/230/60/3 197/254 1 10.4 73.0 3.9 14.3 16.9 25 0.8 15.1 17.7 25 F* 460/60/3* 414/506 1 5.8 38.0 3.2 9.0 10.5 15 0.7 9.7 11.2 15 G 208/230/60/1 197/254 1 21.8 117.0 6.9 28.7 34.2 50 0.8 29.5 35.0 50 E 265/60/1 239/292 1 16.3 98.0 6.0 22.3 26.4 40 0.7 23. 27.1 40 H 208/230/60/3 197/254 1 13.7 83.1 6.9 20.6 24.0 35 0.8 21.4 24.8 35 F* 460/60/3* 414/506 1 6.2 41.0 6.0 12.2 13.8 20 0.7 12.9 14.5 20 G 208/230/60/1 197/254 1 26.4 134.0 6.9 33.3 39.9 60 1.1 34.4 41.0 60 E 265/60/1 239/292 1 19.9 130.0 6.0 25.9 30.9 50 1.3 27.2 32.2 50 H 208/230/60/3 197/254 1 16 110.0 6.9 22.9 26.9 40 1.1 24.0 28.0 40 F* 460/60/3* 414/506 1 7.8 52.0 6.0 13.8 15.8 20 1.3 15.1 17.1 20 G 208/230/60/1 197/254 1 30.8 178.0 6.9 37.7 45.4 70 1.1 37.9 45.6 70 H 208/230/60/3 197/254 1 19.6 138.0 6.9 26.5 31.4 50 1.1 27.6 32.5 50 F* 460/60/3* 414/506 1 8.2 66.1 6.0 14.2 16.3 20 1.3 15.5 17.6 25 * NEUTRAL CONNECTION REQUIRED! All F Voltage (460 vac) units with ECM motors/internal secondary circulators require a four wire power supply with neutral. ECM motors/internal secondary circulators are rated 265 vac and are wired between one hot leg and neutral. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 58 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P TS Series Wiring Diagram Matrix Only CXM and DXM diagrams, with a representative diagram of LON and MPC Options are presented in this submittal. Other diagrams can be located online at climatemaster.com using the part numbers presented below. Model Refrigerant Wiring Diagram Part Number Electrical EarthPure® HFC-410A DDC 96B0006N28 - 96B0006N16 LON 96B0006N14 TS Series Single Phase Control - 96B0006N22 LON 96B0006N20 MPC 96B0006N17 ECM MPC CXM 96B0006N24 96B0006N19 Fan Motor PSC - 208/230-60-1 265-60-1 LON ECM 96B0006N15 MPC ClimaDry® 96B0038N66 DXM 96B0006N25 - 96B0006N23 LON 96B0006N21 MPC 96B0006N33 ClimaDry® PSC 96B0007N18 - 96B0007N16 LON 96B0007N14 MPC ECM CXM TS Series Three Phase (230 Style) EarthPure® HFC-410A 96B0007N24 - 96B0007N22 LON 96B0007N20 MPC 96B0007N19 PSC - 208/230-60-3 96B0007N17 LON 96B0007N15 MPC ECM ClimaDry® 96B0007N29 DXM 96B0007N25 - 96B0007N23 LON 96B0007N21 MPC 96B0007N30 ClimaDry® PSC 96B0008N18 - 96B0008N16 LON 96B0008N14 MPC ECM CXM TS Series Three Phase (460 Style) EarthPure® HFC-410A 96B0008N24 - 96B0008N22 LON 96B0008N20 MPC 96B0008N19 460-60-3 PSC - 96B0008N17 LON 96B0008N15 MPC ECM 96B0216N22 DXM ClimaDry® 96B0008N25 - 96B0008N23 LON 96B0008N21 MPC PSC All wiring diagrams available at climatemaster.com. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 59 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Typical Wiring Diagram – Single Phase TS Units with CXM Controller ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 60 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Typical Wiring Diagram – Three Phase TS Units with DXM Controller ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 61 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Typical Wiring Diagram – Three Phase TS Units with CXM Controller and ECM Blower ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 62 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Typical Wiring Diagram – Single Phase TS Units with CXM, MPC, and ECM Controller ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 63 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Typical Wiring Diagram – Single Phase TS Units with ClimaDry® II and ECM Blower ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 64 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Tranquility® 20 (TS) Series 60Hz Engineering Specifications – Page 1 General: Furnish and install ClimateMaster Tranquility® “TS” Water Source Heat Pumps, as indicated on the plans. Equipment shall be completely assembled, piped and internally wired. Capacities and characteristics as listed in the schedule and the specifications that follow. Units shall be supplied completely factory built capable of operating over an entering water temperature range from 20° to 120°F (-6.7° to 48.9°C) as standard. Equivalent units from other manufacturers may be proposed provided approval to bid is given 10 days prior to bid closing. All equipment listed in this section must be rated and certified in accordance with Air-Conditioning, Heating and Refrigeration Institute/International Standards Organization (AHRI/ISO 13256-1). All equipment must be tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL-1995 for the United States and CAN/CSA-C22.2 NO.236 for Canada, by Intertek Testing Laboratories (ETL). The units shall have AHRI/ISO and ETL-US-C labels. All units shall be fully quality tested by factory run testing under normal operating conditions as described herein. Quality control system shall automatically perform via computer: triple leak check, pressure tests, evacuation and accurately charge system, perform detailed heating and cooling mode tests, and quality cross check all operational and test conditions to pass/fail criteria. Detailed report card will ship with each unit displaying status for critical tests and components. Note: If unit fails on any cross check, it shall not be allowed to ship. Serial numbers will be recorded by factory and furnished to contractor on report card for ease of unit warranty status. Units tested without water flow are not acceptable. Basic Construction: Horizontal Units shall have one of the following air flow arrangements: Left Inlet/Straight (Right) Discharge; Right Inlet/Straight (Left) Discharge; Left Inlet/Back Discharge; or Right Inlet/Back Discharge as shown on the plans. Units must have the ability to be field convertible from straight to back or back to straight discharge with no additional parts or unit structure modification. Horizontal units will have factory installed hanger brackets with rubber isolation grommets packaged separately. Vertical Units shall have one of the following air flow arrangements: Left Return/Top Discharge, Right Return/Top Discharge, Left Return/Bottom Discharge, Right Return/Bottom Discharge as shown on the plans. If units with these arrangements are not used, the contractor is responsible for any extra costs incurred by other trades. All units (horizontal and vertical) must have a minimum of three access panels for serviceability of compressor compartment. Units having only one access panel to compressor/heat exchangers/expansion device/refrigerant piping shall not be acceptable. Compressor section interior surfaces shall be lined with 1/2 inch (12.7mm) thick, 1-1/2 lb/ft3 (24 kg/m3) acoustic type glass fiber insulation. Air handling section interior surfaces shall be lined with 1/2 in (12.7mm) thick, 1-1/2 lb/ft3 (24 kg/m3) foil faced fiber insulation for ease of cleaning. Insulation placement shall be designed in a manner that will eliminate any exposed edges to prevent the introduction of glass fibers into the air stream. Units without foil faced insulation in the air handling section will not be accepted. The heat pumps shall be fabricated from heavy gauge galvanized steel with powder coat paint finish. Both sides of the steel shall be painted for added protection. Standard cabinet panel insulation must meet NFPA 90A requirements, air erosion and mold growth limits of UL-181, stringent fungal resistance test per ASTM-C1071 and ASTM G21, and shall meet zero level bacteria growth per ASTM G22. Unit insulation must meet these stringent requirements or unit(s) will not be accepted. All horizontal units to have factory installed 1” (25.4mm) discharge air duct collars, 1” (25.4mm) filter rails with 1” (25.4mm) filters factory installed, and factory installed unit-mounting brackets. Vertical units to have field installed discharge air duct collar, shipped loose and 1” (25.4mm) filter rails with 1” (25.4mm) filters factory installed. If units with these factory-installed provisions are not used, the contractor is responsible for any extra costs to field install these provisions, and/or the extra costs for his subcontractor to install these provisions. All units must have an insulated panel separating the fan compartment from the compressor compartment. Units with the compressor in the air stream are not acceptable. Units shall have a factory installed 1 inch (25.4mm) wide filter bracket for filter removal from either side. Units shall have a 1 inch (25.4mm) thick throwaway type glass fiber filter. The contractor shall purchase one spare set of filters and replace factory shipped filters on completion of start-up. Filters shall be standard sizes. If units utilize non-standard filter sizes then the contractor shall provide 12 spare filters for each unit. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 65 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Tranquility® 20 (TS) Series 60Hz Engineering Specifications – Page 2 Cabinets shall have separate holes and knockouts for entrance of line voltage and low voltage control wiring. All factory-installed wiring passing through factory knockouts and openings shall be protected from sheet metal edges at openings by plastic ferrules. Supply and return water connections shall be copper FPT fittings, and shall be securely mounted flush to the cabinet corner post allowing for connection to a flexible hose without the use of a back-up wrench. Water connections that protrude through the cabinet or require the use of a backup wrench shall not be allowed. All water connections and electrical knockouts must be in the compressor compartment corner post as to not interfere with the serviceability of unit. Contractor shall be responsible for any extra costs involved in the installation of units that do not have this feature. Contractor must ensure that units can be easily removed for servicing and coordinate locations of electrical conduit and lights with the electrical contractor. Option: Contractor shall install 2-inch (50.8mm) filter racks with removable access door and 2 inch (50.8mm) MERV11 pleated throwaway filters on all units. Option: UltraQuiet package (available on TS018-070 Units) shall consist of high technology sound attenuating material that is strategically applied to the compressor and air handling compartment casings and fan scroll in addition to the standard ClimaQuiet system design, to further dampen and attenuate sound transmissions Option: The unit will be supplied with internally factory mounted two-way water valve for variable speed pumping requirements. A factory-mounted or field-installed high pressure switch shall be installed in the water piping to disable compressor operation in the event water pressures build due to water freezing in the piping system. Option: The unit will be supplied with internally factory mounted automatic water flow regulators. Option: The unit will be supplied with internally mounted secondary pump for primary/secondary applications, including one-pipe systems. Option: The unit shall be supplied with extended range Insulation option, which adds closed cell insulation to internal water lines, and provides insulation on suction side refrigeration tubing including refrigerant to water heat exchanger. Fan and Motor Assembly: Blower shall have inlet rings to allow removal of wheel and motor from one side without removing housing. Units shall have a directdrive centrifugal fan. The fan motor shall be 3-speed (2-speed for 575V), permanently lubricated, PSC type, with internal thermal overload protection. Units supplied without permanently lubricated motors must provide external oilers for easy service. The fan motor on small and medium size units (006-048) shall be isolated from the fan housing by a torsionally flexible motor mounting system with rubber type grommets to inhibit vibration induced high noise levels associated with “hard wire belly band” motor mounting. The fan motor on larger units (060 & 070) shall be isolated with flexible rubber type isolation grommets only. The fan and motor assembly must be capable of overcoming the external static pressures as shown on the schedule. Airflow / Static pressure rating of the unit shall be based on a wet coil and a clean filter in place. Ratings shall NOT be acceptable based on a dry coil and/or no air filter. Option: ECM motors (sizes 018 to 070): The fan motor shall be an ECM variable speed ball bearing type motor. The ECM fan motor shall provide soft starting, maintain constant CFM over its static operating range and provide airflow adjustment on its control board. The fan motor shall be isolated from the housing by rubber grommets. The motor shall be permanently lubricated and have thermal overload protection. A special dehumidification mode shall be provided to allow lower airflows in cooling for better dehumidification. The dehumidification mode shall be selectable via a dip switch on the control board or may be controlled externally from a humidistat. Option: High static PSC motors (sizes 018-060). Refrigerant Circuit: All units shall contain an EarthPure® (HFC-410A) sealed refrigerant circuit including a high efficiency scroll or rotary compressor designed for heat pump operation, a thermostatic expansion valve for refrigerant metering, an enhanced corrugated aluminum lanced fin and rifled copper tube or all aluminum micro channel refrigerant to air heat exchanger, reversing valve, coaxial (tube in tube) refrigerant to water heat exchanger, and safety controls including a high pressure switch, low pressure switch (loss of charge), water coil low temperature sensor, and air coil low temperature sensor. Access fittings shall be factory installed on high and low pressure refrigerant lines to facilitate field service. Activation of any safety device shall prevent compressor operation via a microprocessor lockout circuit. The lockout circuit shall be reset at the thermostat or at the contractor supplied disconnect switch. Units that cannot be reset at the thermostat shall not be acceptable. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 66 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Tranquility® 20 (TS) Series 60Hz Engineering Specifications – Page 3 Hermetic compressors shall be internally sprung. The compressor shall have a dual level vibration isolation system. The compressor will be mounted on specially engineered sound-tested EPDM vibration isolation grommets to a large heavy gauge compressor mounting plate, which is then isolated from the cabinet base with rubber grommets for maximized vibration attenuation. All units (except units with rotary compressors) shall include a discharge muffler to further enhance sound attenuation. Compressor shall have thermal overload protection. Compressor shall be located in an insulated compartment away from air stream to minimize sound transmission. Refrigerant to air heat exchangers shall utilize enhanced corrugated lanced aluminum fins and rifled copper tube or all aluminum micro channel construction rated to withstand 625 PSIG (4309 kPa) refrigerant working pressure. Refrigerant to water heat exchangers shall be of copper inner water tube and steel refrigerant outer tube design, rated to withstand 625 PSIG (4309 kPa) working refrigerant pressure and 500 PSIG (3445 kPa) working water pressure. The refrigerant to water heat exchanger shall be “electro-coated” with a low cure cathodic epoxy material a minimum of 0.4 mils thick (0.4 – 1.5 mils range) on all surfaces. The black colored coating shall provide a minimum of 1000 hours salt spray protection per ASTM B117-97 on all external steel and copper tubing. The material shall be formulated without the inclusion of any heavy metals and shall exhibit a pencil hardness of 2H (ASTM D3363-92A), crosshatch adhesion of 4B-5B (ASTM D3359-95), and impact resistance of 160 in-lbs (184 kg-cm) direct (ASTM D2794-93). Refrigerant metering shall be accomplished by thermostatic expansion valve only. Expansion valves shall be dual port balanced types with external equalizer for optimum refrigerant metering. Units shall be designed and tested for operating ranges of entering water temperatures from 20° to 120°F (-6.7° to 48.9°C). Reversing valve shall be four-way solenoid activated refrigerant valve, which shall default to heating mode should the solenoid fail to function. If the reversing valve solenoid defaults to cooling mode, an additional low temperature thermostat must be provided to prevent over-cooling an already cold room. Option: The unit shall be supplied with a hot water generator (desuperheater). Option: The unit will be supplied with cupro-nickel coaxial water to refrigerant heat exchanger. Option: The refrigerant to air heat exchanger shall be coated. Option: Unit shall include ClimaDry®II reheat option. Only modulating reheat that will adjust capacity based upon supply air temperature to provide “neutral” (72ºF, 22.2ºC) constant air temperature will be accepted. “Neutral” supply air temperature shall be provided regardless of entering loop water temperatures (above 55ºF, 12.8ºC) or refrigerant condensing pressures. Control of reheat must be accomplished via a humidistat or dehumidistat contact closure. Refrigerant circuit must be AHRI certified. Approved equal manufacturers may provide pre-engineered integrated modulating hot gas reheat within the unit cabinet, or the installing contractor in conjunction with the “approved equal” unit manufacturer can provide for approval (during the submittal phase) an engineered system consisting of: a duct mounted hot water coil, small circulating pump, modulating control valve, and associated piping using the discharge condenser water off of the unit as the heating medium. All design costs and costs of field installed items including additional power wiring to pump, and control wiring to and from pump and control valve to unit shall be borne by mechanical contractor. Refrigerant circuits that are not AHRI certified when the reheat option is applied will not be accepted. Drain Pan: The drain pan shall be constructed of 201LN Stainless Steel to inhibit corrosion. This corrosion protection system shall meet the stringent 1000 hour salt spray test per ASTM B117. If plastic type material is used, it must be HDPE (High Density Polyethylene) to avoid thermal cycling shock stress failure over the lifetime of the unit. Drain pan shall be fully insulated. Drain outlet shall be located at pan as to allow unobstructed drainage of condensate. Drain outlet for horizontal units shall be connected from pan directly to FPT fitting. No hidden internal tubing extensions from pan outlet extending to unit casing (that can create drainage problems) will be accepted. The unit as standard will be supplied with solid-state electronic condensate overflow protection. Mechanical float switches will NOT be accepted. Vertical units shall be furnished with a PVC FPT condensate drain connection and an internal factory installed condensate trap. If units without an internal trap are used, the contractor is responsible for any extra costs to field install these provisions, and/or the extra costs for his sub-contractor to install these provisions. Electrical: A control box shall be located within the unit compressor compartment and shall contain a 50VA transformer, 24 volt activated, 2 or 3 pole compressor contactor, terminal block for thermostat wiring and solid-state controller for complete unit operation. Reversing valve and fan motor wiring shall be routed through this electronic controller. Units shall be name-plated for use with time delay fuses or HACR circuit breakers. Unit controls shall be 24 Volt and provide heating or cooling as required by the remote thermostat/sensor. Option: Units shall be supplied with factory installed non-fused electrical service disconnect switch. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 67 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Tranquility® 20 (TS) Series 60Hz Engineering Specifications – Page 4 Solid State Control System (CXM): Units shall have a solid-state control system. Units utilizing electro-mechanical control shall not be acceptable. The control system microprocessor board shall be specifically designed to protect against building electrical system noise contamination, EMI, and RFI interference. The control system shall interface with a heat pump type thermostat. The control system shall have the following features: a. b. c. d. e. f. g. h. i. j. k. l. m. n. o. p. Anti-short cycle time delay on compressor operation. Random start on power up mode. Low voltage protection. High voltage protection. Unit shutdown on high or low refrigerant pressures. Unit shutdown on low water temperature. Condensate overflow electronic protection. Option to reset unit at thermostat or disconnect. Automatic intelligent reset. Unit shall automatically reset the unit 5 minutes after trip if the fault has cleared. If a fault occurs 3 times sequentially without thermostat meeting temperature, then lockout requiring manual reset will occur. Ability to defeat time delays for servicing. Light emitting diode (LED) on circuit board to indicate high pressure, low pressure, low voltage, high voltage, low water/air temperature cut-out, condensate overflow, and control voltage status. The low-pressure switch shall not be monitored for the first 120 seconds after a compressor start command to prevent nuisance safety trips. 24V output to cycle a motorized water valve or other device with compressor contactor. Unit Performance Sentinel (UPS). The UPS warns when the heat pump is running inefficiently. Water coil low temperature sensing (selectable for water or antifreeze). Air coil low temperature sensing. NOTE: Units not providing the 8 safety protections of anti-short cycle, low voltage, high voltage, high refrigerant pressure, low pressure (loss of charge), air coil low temperature cut-out, water coil low temperature cut-out, and condensate overflow protections will not be accepted. Solid State ECM Fan Control Board (60 Hz Units with ECM Fan Option Only): Airflow selection shall be accomplished via 3 jumper switches on the ECM control board. Actual airflow shall be indicated by the CFM LED with each 100 CFM being represented by one flash of the LED. Airflow shall be automatically maintained (±5%) by the ECM motor regardless of external static pressure up to its maximum output capacity. A jumper shall allow selection of a special dehumidification mode, which reduces airflow in cooling by 25% to increase the latent capacity of the unit. A terminal shall be provided on the control board to allow an external humidistat to activate dehumidification mode. Option: Enhanced solid state control system (DXM) This control system features two stage control of cooling and two stage control of heating modes for exacting temperature and dehumidification purposes. This control system coupled with a multi-stage thermostat will better dehumidify room air by automatically running the heat pump’s fan at lower speed on the first stage of cooling thereby implementing low sensible heat ratio cooling. On the need for higher cooling performance the system will activate the second stage of cooling and automatically switch the fan to the higher fan speed setting. This system may be further enhanced with a humidistat. Units not having automatic low sensible heat ratio cooling will not be accepted; as an alternate a hot gas reheat coil may be provided with control system for automatic activation. Control shall have all of the above mentioned features of the CXM control system along with the following expanded features: a. b. c. d. e. f. g. h. i. Removable thermostat connector. Night setback control. Random start on return from night setback. Minimized reversing valve operation (Unit control logic shall only switch the reversing valve when cooling is demanded for the first time. The reversing valve shall be held in this position until the first call for heating, ensuring quiet operation and increased valve life.). Override temperature control with 2-hour timer for room occupant to override setback temperature at the thermostat. Dry contact night setback output for digital night setback thermostats. Ability to work with heat pump or heat/cool (Y,W) type thermostats. Ability to work with heat pump thermostats using O or B reversing valve control. Emergency shutdown contacts. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 68 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Tranquility® 20 (TS) Series 60Hz Engineering Specifications – Page 5 j. k. l. m. n. o. Boilerless system heat control at low loop water temperature. Ability to allow up to 3 units to be controlled by one thermostat. Relay to operate an external damper. Ability to automatically change fan speed from multistage thermostat. Relay to start system pump. 75 VA control transformer. Control transformer shall have load side short circuit and overload protection via a built in circuit breaker. Digital Night Setback with Pump Restart (DXM w/ ATP32U03/04) The unit will be provided with a Digital Night Setback feature using an accessory relay on the DXM controller with an ATP32U03/04 thermostat and an external, field-provided time clock. The external time clock will initiate and terminate the night setback period. The thermostat will have a night setback override feature with a programmable override time period. An additional accessory relay on the unit DXM controller will energize the building loop pump control for the duration of the override period. (Note: this feature requires additional low voltage wiring. Consult Application Drawings for details.) Remote Service Sentinel (CXM/DXM): Solid state control system shall communicate with thermostat to display (at the thermostat) the unit status, fault status, and specific fault condition, as well as retrieve previously stored fault that caused unit shutdown. The Remote Service Sentinel allows building maintenance personnel or service personnel to diagnose unit from the wall thermostat. The control board shall provide a signal to the thermostat fault light, indicating a lockout. Upon cycling the G (fan) input 3 times within a 60 second time period, the fault light shall display the specific code as indicated by a sequence of flashes. A detailed flashing code shall be provided at the thermostat LED to display unit status and specific fault status such as over/under voltage fault, high pressure fault, low pressure fault, low water temperature fault, condensate overflow fault, etc. Units that do not provide this remote service sentinel shall not be acceptable. Option: Lonworks interface system Units shall have all the features listed above (either CXM or DXM) and the control board will be supplied with a LONWORKS interface board, which is LONMark certified. This will permit all units to be daisy chained via a 2-wire twisted pair shielded cable. The following points must be available at a central or remote computer location: a. b. c. d. e. f. g. h. i. j. k. l. m. n. o. p. q. r. space temperature leaving water temperature discharge air temperature command of space temperature setpoint cooling status heating status low temperature sensor alarm low pressure sensor alarm high pressure switch alarm condensate sensor alarm hi/low voltage alarm fan “ON/AUTO” position of space thermostat as specified above unoccupied/occupied command cooling command heating command fan “ON/AUTO” command fault reset command itemized fault code revealing reason for specific shutdown fault (any one of 7) This option also provides the upgraded 75VA control transformer with load side short circuit and overload protection via a built in circuit breaker. Option: MPC (Multiple Protocol Control) interface system Units shall have all the features listed above (either CXM or DXM) and the control board will be supplied with a Multiple Protocol interface board. Available protocols are BACnet MS/TP, Modbus, or Johnson Controls N2. The choice of protocol shall be field selectable/changeable via the use of a simple selector switch. Protocol selection shall not require any additional programming or special external hardware or software tools. This will permit all units to be daisy chain connected by a 2-wire twisted pair shielded cable. The following points must be available at a central or remote computer location: ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 69 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Tranquility® 20 (TS) Series 60Hz Engineering Specifications – Page 6 a. b. c. d. e. f. g. h. i. j. k. l. m. n. o. p. q. r. space temperature leaving water temperature discharge air temperature command of space temperature setpoint cooling status heating status low temperature sensor alarm low pressure sensor alarm high pressure switch alarm condensate overflow alarm hi/low voltage alarm fan “ON/AUTO” position of space thermostat as specified above unoccupied / occupied command cooling command heating command fan “ON/AUTO” command fault reset command itemized fault code revealing reason for specific shutdown fault (any one of 7) This option also provides the upgraded 75VA control transformer with load side short circuit and overload protection via a built in circuit breaker. Warranty: Climate Master shall warranty equipment for a period of 12 months from start up or 18 months from shipping (which ever occurs first). Option: Extended 4-year compressor warranty covers compressor for a total of 5 years. Option: Extended 4-year refrigeration circuit warranty covers coils, reversing valve, expansion valve and compressor for a total of 5 years. Option: Extended 4-year control board warranty covers the CXM/DXM control board for a total of 5 years. FIELD INSTALLED OPTIONS Hose Kits: All units shall be connected with hoses. The hoses shall be 2 feet (61cm) long, braided stainless steel; fire rated hoses complete with adapters. Only fire rated hoses will be accepted. Valves: The following valves are available and will be shipped loose: a. Ball valve; bronze material, standard port full flow design, FPT connections. b. Ball valve with memory stop and PT port. c. “Y” strainer with blowdown valve; bronze material, FPT connections. d. Motorized water valve; slow acting, 24v, FPT connections. Hose Kit Assemblies: The following assemblies ship with the valves already assembled to the hose described: a. Supply and return hoses having ball valve with PT port. b. Supply hose having ball valve with PT port; return hose having automatic flow regulator valve with PT ports, and ball valve. c. Supply hose having “Y” strainer with blowdown valve, and ball valve with PT port; return hose having automatic flow regulator with PT ports, and ball valve. d. Supply hose having “Y” strainer with blowdown valve, and ball valve with PT port; return hose having ball valve with PT port. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 70 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Tranquility® 20 (TS) Series 60Hz Engineering Specifications – Page 7 Thermostats: The thermostat shall be a ClimateMaster mechanical or electronic type thermostat as selected below with the described features: a. Single Stage Standard Manual Changeover (ATM11C11) Thermostat shall be a single-stage, horizontal mount, manual changeover with HEAT-OFF-COOL system switch and fan ON-AUTO switch. Thermostat shall have a mechanical temperature set point indicator. Thermostat shall only require 4 wires for connection. Mercury bulb thermostats are not acceptable. b. Single Stage Digital Auto or Manual Changeover (ATA11U01) Thermostat shall be a single-stage, digital, auto or manual changeover with HEAT-OFF-COOL-AUTO system switch and fan ONAUTO switch. Thermostat shall have an LCD display with temperature and set-point(s) in ºF or ºC. The Thermostat shall provide permanent memory of set-point(s) without batteries. A fault LED shall be provided to display specific fault condition. Thermostat shall provide temperature display offset for custom applications. c. Single Stage Digital Auto or Manual Changeover and Manual Two Fan Speed Selections (ATA11U03) Thermostat shall be a single-stage, digital, auto or manual changeover with HEAT-OFF-COOL-AUTO system settings, high and low fan settings and fan ON-AUTO settings. Thermostat shall have an LCD display with temperature, setpoint(s), mode, and status indication. The temperature indication shall be selectable for ºF or ºC. The thermostat shall provide permanent memory of setpoint(s) without batteries. Thermostat shall provide heating setpoint range limit, cooling setpoint range limit, temperature display offset, keypad lockout, dead-band range setting, and inter-stage differential settings. Thermostat shall allow the use of an accessory remote temperature sensor (17B0008N05). Thermostat navigation shall be accomplished via 4 push buttons. d. Multistage Digital Automatic Changeover (ATA22U01) Thermostat shall be multi-stage (2H/2C), manual or automatic changeover with HEAT-OFF-COOL-AUTO-EM HEAT system settings and fan ON-AUTO settings. Thermostat shall have an LCD display with temperature, set-point(s), mode, and status indication. The temperature indication shall be selectable for ºF or ºC. The thermostat shall provide permanent memory of set-point(s) without batteries. A fault LED shall be provided to indicate specific fault condition(s). Thermostat shall provide temperature display offset for custom applications. Thermostat shall allow unit to provide better dehumidification with optional DXM controller by automatically using lower fan speed on stage 1 cooling (higher latent cooling) as main cooling mode, and automatically shifting to high speed fan on stage 2 cooling. e. Multistage Manual Changeover Programmable 5/2 Day (ATP21U01) Thermostat shall be 5 day/2 day programmable (with up to 4 set points per day), multi-stage (2H/1C), manual changeover with HEAT-OFF-COOL-EM HEAT system settings and fan ON-AUTO settings. Thermostat shall have an LCD display with temperature, set-point(s), mode, and status indication. The temperature indication shall be selectable for ºF or ºC. The thermostat shall provide permanent memory of set-point(s) without batteries. Thermostat shall provide convenient override feature to temporarily change setpoint. f. Multistage Automatic or Manual Changeover Programmable 7 Day (ATP32U03C) Thermostat shall be 7 day programmable (with up to 4 set points per day), multi-stage (3H/2C), automatic or manual changeover with HEAT-OFF-COOL-AUTO-EM HEAT system settings and fan ON-AUTO settings. Thermostat shall have a blue backlit dot matrix LCD display with temperature, set-points, mode, and status indication. The temperature indication shall be selectable for ºF or ºC. Time display shall be selectable for 12 or 24 hour clock. Fault identification shall be provided (when used with ClimateMaster CXM or DXM controls) to simplify troubleshooting by providing specific unit fault at the thermostat with red backlit LCD during unit lockout. The thermostat shall provide permanent memory of set-points without batteries. Thermostat shall provide heating set-point range limit, cooling set-point range limit, temperature display offset, keypad lockout, dead-band range setting, and interstage differential settings. Thermostat shall provide progressive recovery to anticipate time required to bring space temperature to the next programmed event. Thermostat shall provide an installer setup for configuring options and for setup of servicing contractor name and contact information. Thermostat shall allow the use of an accessory remote and/or outdoor temperature sensor (AST008). Thermostat navigation shall be accomplished via five buttons (up/down/right/left/select) with menu-driven selections for ease of use and programming. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 71 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Tranquility® 20 (TS) Series 60Hz Engineering Specifications – Page 8 g. Multistage Automatic or Manual Changeover Programmable 7 Day with Humidity Control (ATP32U04C) Thermostat shall be 7 day programmable (with up to 4 set points per day), multi-stage (3H/2C), automatic or manual changeover with HEAT-OFF-COOL-AUTO-EM HEAT system settings and fan ON-AUTO settings. Separate dehumidification and humidification set points shall be configurable for discreet outputs to a dehumidification option and/or an external humidifier. Installer configuration mode shall allow thermostat dehumidification mode to operate with ClimaDry® reheat or with ECM fan dehumidification mode via settings changes. Thermostat shall have a blue backlit dot matrix LCD display with temperature, relative humidity, set-points, mode, and status indication. The temperature indication shall be selectable for ºF or ºC. Time display shall be selectable for 12 or 24 hour clock. Fault identification shall be provided (when used with ClimateMaster CXM or DXM controls) to simplify troubleshooting by providing specific unit fault at the thermostat with red backlit LCD during unit lockout. The thermostat shall provide permanent memory of set-points without batteries. Thermostat shall provide heating set-point range limit, cooling set-point range limit, temperature display offset, keypad lockout, dead-band range setting, and inter-stage differential settings. Thermostat shall provide progressive recovery to anticipate time required to bring space temperature to the next programmed event. Thermostat shall provide an installer setup for configuring options and for setup of servicing contractor name and contact information. Thermostat shall allow the use of an accessory remote and/or outdoor temperature sensor (AST008). Thermostat navigation shall be accomplished via five buttons (up/down/right/left/select) with menu-driven selections for ease of use and programming. DDC Sensors: ClimateMaster wall mounted DDC sensor to monitor room temperature and interfaces with optional interface system described above. Several types as described below: a. Sensor only with no display (LON and MPC). b. Sensor with override (LON only). c. Sensor with setpoint adjustment and override (MPC only). d. Sensor with setpoint adjustment and override, LCD display, status/fault indication (LON and MPC). ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 72 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Notes: ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 73 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Notes: ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 74 Rev.: 23 October,2015 Page ______ of ______ TS Series 60Hz - HFC-410A Submittal Data Eng/I-P Notes: ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 75 Rev.: 23 October,2015 Page ______ of ______ Revision Log TS Series 60Hz - HFC-410A Submittal Data Date 10/22/15 08/04/15 07/22/15 06/17/15 03/25/15 03/05/15 01/23/15 12/16/14 09/30/14 08/15/14 06/12/14 05/12/14 03/31/14 03/24/14 02/10/14 01/27/14 7/17/13 02/26/13 01/07/13 09/27/12 02/20/12 02/02/12 12/14/11 11/02/11 10/19/11 08/09/11 08/03/11 06/17/11 05/16/11 04/07/11 02/11/11 01/03/11 09/29/10 09/28/10 09/07/10 09/01/10 08/24/10 07/26/10 07/26/10 06/11/10 06/11/10 06/01/10 03/30/10 05/27/09 04/29/09 04/29/09 11/17/08 09/19/08 08/26/08 08/01/08 08/0407 05/14/07 04/19/07 04/19/07 12/14/06 11/16/06 11/16/06 11/16/06 11/19/06 11/19/06 07/19/06 07/19/06 07/19/06 12/23/05 11/30/05 11/30/05 11/30/05 11/30/05 08/15/05 08/15/05 08/15/05 08/15/05 08/15/05 06/20/05 06/20/05 06/20/05 06/20/05 03/30/05 03/30/05 03/30/05 Item: Pages 48 and 51 Engineering Specifications and Unit Features Page 13 & 14 Decoder - Page 7; Tables - Pages 13 & 53-58 Table - Page 43 Decoder - Page 7 Table - Page 56 Edits - Page 45 & 47 Text Edit - Page 67 TS060 E Voltage Elec. Tables Rev. C Size 036 E Voltage Air Coil Description page 66-67 Illustration - Page 48 ECM Blower Data - Page 38 Page 41 All EAT Minimum Limit ClimaDry AHRI Table Physical Data Table TS Vertical Upflow - Dimensional Data - TSV Right Return EAT Limits Recommended Minimum Installation Clearances for Vertical Units * Engineering Specifications ClimaDry® II option Information ECM Control Decoder Dimensional Data, Optional Filter Frame Unit Maximum Working Water Pressure Engineering Specifications Coated Air Coil Option Electrical Data 018E and 024F ISP Engineering Specification NOTICE Performance Data Selection Notes Format - All Pages ECM Electrical Data Engineering Specifications ECM Blower Control Engineering Specifications Horizontal Units Wiring Diagrams Compressor Mounting Information and Graphics Format - All Pages Engineering Specifiations TSH S.A. Dimensions Performance Data/Blower Data Stand-Alone and Big Book Submittals Electrical Data Table (High Static PSC Motor & Secondary Pump) Performance Data IP Table Corrected TS HorizontaL Data Table Engineering Specifications Physical Data Table Electrical Data Table All All Table of Contents Specifications Dimensional Data Electrical Data Dimensional Data Performance Data/Blower Data Specifications Wiring Diagrams Electrical Data ECM Blower Performance Performance Data Motorized Valves Tables Dimensional data Physical Data Blower Data, Electrical Data, Unit Specifications Correction Factors Physical Data Dimensional Data Electrical Data Specifications Entire Document Electrical Data ECM Motor Specifications Electrical Data Horizontal Dimensions Added Revision Log Eng/I-P Action: Edited dimensions “T” on sizes 42,48 Updated, ECM Options Text, Edited Compressors Mount Text, Fan and Motor Assembly Text Updated HWC Data Updated Updated Maximum Working Water Pressure Updated Updated Updated Updated Added ECM with ISP and CWR Added Updated Updated Updated Max ESP Updated Table 2 Updated Sizes 024-070 to Rev. C, added service clearances Updated Size 018 PSC Updated Updated Updated Blower Orientation Updated Updated Merge data from ClimaDry® II Submittal Updated CFM adjust settings Updated Added Updated to Reflect New Safeties Added Digital Night Setback with Pump Restart (DXM w/ ATP32U03/04) Changed Description Added Updated Updated Updated Updated Updated Added Ramp Down Feature Updated Supply Air Dimension M and Q updated Updated Updated to Reflect Spring/Grommet Change Updated Updated Dimension M & Q changed Size 018 data changes Consolidated 036 E Data Corrected Data Corrected ClimaDry® Note Added Max Working Pressure Table Added Asterisks Added Added Sizes 006, 009, & 012 Updated Size 018 for Rev.: B Added Table of Contents Updated Specifications for new Safety Agency Corrected TSH18-030 Supply dimensions Various updates Updated dimensional data to new format Added new rated voltage note Updated thermostat offering Added pressure switch for motorized valve option Added secondary pump data, updated ClimaDry® data, various formatting changes Updated CFM data Added low temperature selection notes Added Cv, MOPD, and WPD data Updated all tables to new format Added new dimensional drawings and installation and service notes Added Coax volumes Added ClimaDry® Reheat option Updated verbiage - No data changes Added Coax volume chart Added corner weights - Horizontal units Updated 030 “E” voltage total unit FLA & MCA Updated verbiage in CXM section Updated to Adobe Acrobat 7.0 Removed TS024 265V data Added Information on new interface board Updated specs to include mufflers Updated 018, 024, 030 Updated dim. “H” ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC377 - 76 Rev.: 23 October,2015 Page ______ of ______
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement