TSQ Series TSQ Quantum XLS and TSQ Quantum GC User Guide 70111-97220 Revision A March 2010 © 2009 Thermo Fisher Scientific Inc. All rights reserved. Swagelok™ is a trademark of the Crawford Fitting Company. Dranetz™ is a trademark of Dranetz Technologies, Inc. Styrofoam™ is a trademark of Dow Chemical Company. Teflon™ is a trademark of E. I. du Pont de Nemours & Co. Tygon™ is a trademark of Norton Company. Dust-Off™is a trademark of Falcon™ Safety Products. Micro-Blast™ is a trademark of MicroCare™ Corporation. Restek™ is a trademark of Restek Corporation. Dremel, Vespel Thermo Fisher Scientific Inc. provides this document to its customers with a product purchase to use in the product operation. This document is copyright protected and any reproduction of the whole or any part of this document is strictly prohibited, except with the written authorization of Thermo Fisher Scientific Inc. The contents of this document are subject to change without notice. All technical information in this document is for reference purposes only. System configurations and specifications in this document supersede all previous information received by the purchaser. Thermo Fisher Scientific Inc. makes no representations that this document is complete, accurate or errorfree and assumes no responsibility and will not be liable for any errors, omissions, damage or loss that might result from any use of this document, even if the information in the document is followed properly. This document is not part of any sales contract between Thermo Fisher Scientific Inc. and a purchaser. This document shall in no way govern or modify any Terms and Conditions of Sale, which Terms and Conditions of Sale shall govern all conflicting information between the two documents. Release history: Revision A March 2010 Software version: Xcalibur 2.1, TSQ 2.3 For Research Use Only. Not for use in diagnostic procedures. Regulatory Compliance Thermo Fisher Scientific performs complete testing and evaluation of its products to ensure full compliance with applicable domestic and international regulations. When the system is delivered to you, it meets all pertinent electromagnetic compatibility (EMC) and safety standards as described in the next section or sections by product name. Changes that you make to your system may void compliance with one or more of these EMC and safety standards. Changes to your system include replacing a part or adding components, options, or peripherals not specifically authorized and qualified by Thermo Fisher Scientific. To ensure continued compliance with EMC and safety standards, replacement parts and additional components, options, and peripherals must be ordered from Thermo Fisher Scientific or one of its authorized representatives. TSQ Quantum XLS (not reviewed) EMC Directive 89/336/EEC as amended by 92/31/EEC and 93/68/EEC EMC compliance has been evaluated by TUV Rheinland of North America Inc. EN 55011 1998, 1999, 2002 EN 61000-4-3 2002 EN 61000-3-2 1995, A1; 1998, A2; 1998, A14; 2000 EN 61000-4-4 1995, A1; 2000, A2; 2001 EN 61000-3-3 1998, 2001 EN 61000-4-5 1995, A1; 2001 EN 61326-1 1998, 2001, 2003 EN 61000-4-6 1996, A1; 2003 EN 61000-4-2 2001 EN 61000-4-11 1994, A1; 2001 CISPR 11 1998 FCC Class A, CFR 47 Part 15 TSQ Quantum GC EMC Directive 89/336/EEC as amended by 92/31/EEC and 93/68/EEC EMC compliance has been evaluated by TUV Rheinland of North America Inc. EN 55011 1998, 1999, 2002 EN 61000-4-3 2002 EN 61000-3-2 1995, A1; 1998, A2; 1998, A14; 2000 EN 61000-4-4 1995, A1; 2000, A2; 2001 EN 61000-3-3 1998, 2001 EN 61000-4-5 1995, A1; 2001 EN 61326-1 1998, 2001, 2003 EN 61000-4-6 1996, A1; 2003 EN 61000-4-2 2001 EN 61000-4-11 1994, A1; 2001 CISPR 11 1998 FCC Class A, CFR 47 Part 15 Low Voltage Safety Compliance Compliance with safety issues is declared under Thermo Fisher Scientific sole responsibility. This device complies with Low Voltage Directive 73/23/EEC and harmonized standard EN 61010-1:2001. Changes that you make to your system may void compliance with one or more of these EMC and safety standards. Changes to your system include replacing a part or adding components, options, or peripherals not specifically authorized and qualified by Thermo Fisher Scientific. To ensure continued compliance with EMC and safety standards, replacement parts and additional components, options, and peripherals must be ordered from Thermo Fisher Scientific or one of its authorized representatives. FCC Compliance Statement THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTErfERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTErfERENCE RECEIVED, INCLUDING INTErfERENCE THAT MAY CAUSE UNDESIRED OPERATION. CAUTION Read and understand the various precautionary notes, signs, and symbols contained inside this manual pertaining to the safe use and operation of this product before using the device. Notice on Lifting and Handling of Thermo Fisher Scientific San Jose Instruments For your safety, and in compliance with international regulations, the physical handling of this Thermo Fisher Scientific San Jose instrument requires a team effort to lift and/or move the instrument. This instrument is too heavy and/or bulky for one person alone to handle safely. Notice on the Proper Use of Thermo Fisher Scientific San Jose Instruments In compliance with international regulations: Use of this instrument in a manner not specified by Thermo Fisher Scientific San Jose could impair any protection provided by the instrument. Notice on the Susceptibility to Electromagnetic Transmissions Your instrument is designed to work in a controlled electromagnetic environment. Do not use radio frequency transmitters, such as mobile phones, in close proximity to the instrument. WEEE Compliance This product is required to comply with the European Union’s Waste Electrical & Electronic Equipment (WEEE) Directive 2002/96/EC. It is marked with the following symbol: Thermo Fisher Scientific has contracted with one or more recycling or disposal companies in each European Union (EU) Member State, and these companies should dispose of or recycle this product. See www.thermo.com/ WEEERoHS for further information on Thermo Fisher Scientific’s compliance with these Directives and the recyclers in your country. WEEE Konformität Dieses Produkt muss die EU Waste Electrical & Electronic Equipment (WEEE) Richtlinie 2002/96/EC erfüllen. Das Produkt ist durch folgendes Symbol gekennzeichnet: Thermo Fisher Scientific hat Vereinbarungen mit Verwertungs-/Entsorgungsfirmen in allen EU-Mitgliedsstaaten getroffen, damit dieses Produkt durch diese Firmen wiederverwertet oder entsorgt werden kann. Mehr Information über die Einhaltung dieser Anweisungen durch Thermo Fisher Scientific, über die Verwerter, und weitere Hinweise, die nützlich sind, um die Produkte zu identifizieren, die unter diese RoHS Anweisung fallen, finden sie unter www.thermo.com/WEEERoHS. Conformité DEEE Ce produit doit être conforme à la directive européenne (2002/96/EC) des Déchets d'Equipements Electriques et Electroniques (DEEE). Il est marqué par le symbole suivant: Thermo Fisher Scientific s'est associé avec une ou plusieurs compagnies de recyclage dans chaque état membre de l’union européenne et ce produit devrait être collecté ou recyclé par celles-ci. Davantage d'informations sur la conformité de Thermo Fisher Scientific à ces directives, les recycleurs dans votre pays et les informations sur les produits Thermo Fisher Scientific qui peuvent aider la détection des substances sujettes à la directive RoHS sont disponibles sur www.thermo.com/WEEERoHS. CAUTION Symbol CAUTION VORSICHT ATTENTION PRECAUCION AVVERTENZA Electric Shock: This instrument uses high voltages that can cause personal injury. Before servicing, shut down the instrument and disconnect the instrument from line power. Keep the top cover on while operating the instrument. Do not remove protective covers from PCBs. Elektroschock: In diesem Gerät werden Hochspannungen verwendet, die Verletzungen verursachen können. Vor Wartungsarbeiten muß das Gerät abgeschaltet und vom Netz getrennt werden. Betreiben Sie Wartungsarbeiten nicht mit abgenommenem Deckel. Nehmen Sie die Schutzabdeckung von Leiterplatten nicht ab. Choc électrique: L’instrument utilise des tensions capables d’infliger des blessures corprelles. L’instrument doit être arrêté et débranché de la source de courant avant tout intervention. Ne pas utiliser l’instrument sans son couvercle. Ne pas elensver les étuis protecteurs des cartes de circuits imprimés. Descarga eléctrica: Este instrumento utiliza altas tensiones, capaces de producir lesiones personales. Antes de dar servicio de mantenimiento al instrumento, éste debera apagarse y desconectarse de la línea de alimentacion eléctrica. No opere el instrumento sin sus cubiertas exteriores quitadas. No remueva las cubiertas protectoras de las tarjetas de circuito impreso. Shock da folgorazione. L’apparecchio è alimentato da corrente ad alta tensione che puo provocare lesioni fisiche. Prima di effettuare qualsiasi intervento di manutenzione occorre spegnere ed isolare l’apparecchio dalla linea elettrica. Non attivare lo strumento senza lo schermo superiore. Non togliere i coperchi a protezione dalle schede di circuito stampato (PCB). Chemical: This instrument might contain hazardous chemicals. Wear gloves when handling toxic, carcinogenic, mutagenic, or corrosive or irritant chemicals. Use approved containers and proper procedures to dispose waste oil. Chemikalien: Dieses Gerät kann gefährliche Chemikalien enthalten. Tragen Sie Schutzhandschuhe beim Umgang mit toxischen, karzinogenen, mutagenen oder ätzenden/reizenden Chemikalien. Entsorgen Sie verbrauchtes Öl entsprechend den Vorschriften in den vorgeschriebenen Behältern. Chimique: Des produits chemiques dangereux peuven se trouver dans l’instrument. Proted dos gants pour manipuler tous produits chemiques toxiques, cancérigènes, mutagènes, ou corrosifs/irritants. Utiliser des récipients et des procédures homologuées pour se débarrasser des déchets d’huile. Química: El instrumento puede contener productos quimicos peligrosos. Utilice guantes al manejar productos quimicos tóxicos, carcinogenos, mutagenos o corrosivos/irritantes. Utilice recipientes y procedimientos aprobados para deshacerse del aceite usado. Prodotti chimici. Possibile presenza di sostanze chimiche pericolose nell’apparecchio. Indossare dei guanti per maneggiare prodotti chimici tossici, cancerogeni, mutageni, o corrosivi/irritanti. Utilizzare contenitori aprovo e seguire la procedura indicata per lo smaltimento dei residui di olio. Heat: Before servicing the instrument, allow any heated components to cool. Hitze: Warten Sie erhitzte Komponenten erst nachdem diese sich abgekühlt haben. Haute Temperature: Permettre aux composants chauffés de refroidir avant tout intervention. Altas temperaturas: Permita que lop componentes se enfríen, ante de efectuar servicio de mantenimiento. Calore. Attendere che i componenti riscaldati si raffreddino prima di effetturare l’intervento di manutenzione. Fire: Use care when operating the system in the presence of flammable gases. Feuer: Beachten Sie die einschlägigen VorsichtsmaBnahmen, wenn Sie das System in Gegenwart von entzündbaren Gasen betreiben. Incendie: Agir avec précaution lors de l’utilisation du système en présence de gaz inflammables. Fuego: Tenga cuidado al operar el sistema en presencia de gases inflamables. Incendio. Adottare le dovute precauzioni quando si usa il sistema in presenza di gas infiammabili. Eye Hazard: Eye damage could occur from splattered chemicals or flying particles. Wear safety glasses when handling chemicals or servicing the instrument. Verletzungsgefahr der Augen: Verspritzte Chemikalien oder kleine Partikel können Augenverletzungen verursachen. Tragen Sie beim Umgang mit Chemikalien oder bei der Wartung des Gerätes eine Schutzbrille. Danger pour les yeux: Dex projections chimiques, liquides, ou solides peuvent être dangereuses pour les yeux. Porter des lunettes de protection lors de toute manipulationde produit chimique ou pour toute intervention sur l’instrument. Peligro par los ojos: Las salicaduras de productos químicos o particulas que salten bruscamente pueden causar lesiones en los ojos. Utilice anteojos protectores al mnipular productos químicos o al darle servicio de mantenimiento al instrumento. Pericolo per la vista. Gli schizzi di prodotti chimici o delle particelle presenti nell’aria potrebbero causare danni alla vista. Indossare occhiali protettivi quando si maneggiano prodotti chimici o si effettuano interventi di manutenzione sull’apparecchio. General Hazard: A hazard is present that is not included in the above categories. Also, this symbol appears on the instrument to refer the user to instructions in this manual. Allgemeine Gefahr: Es besteht eine weitere Gefahr, die nicht in den vorstehenden Kategorien beschrieben ist. Dieses Symbol wird im Handbuch auBerdem dazu verwendet, um den Benutzer auf Anweisungen hinzuweisen. Danger général: Indique la présence d;un risque n’appartenant pas aux catégories citées plus haut. Ce symbole figure également sur l’instrument pour renvoyer l’utilisateur aux instructions du présent manuel. Peligro general: Significa que existe un peligro no incluido en las categorias anteriores. Este simbolo también se utiliza en el instrumento par referir al usuario a las instrucciones contenidas en este manual. Pericolo generico. Pericolo non compreso tra le precedenti categorie. Questo simbolo è utilizzato inoltre sull’apparecchio per segnalare all’utente di consultare le istruzioni descritte nel presente manuale. When the safety of a procedure is questionable, contact your local Technical Support organization for Thermo Fisher Scientific San Jose Products. Wenn Sie sich über die Sicherheit eines Verfahrens im unklaren sind, setzen Sie sich, bevor Sie fortfahren, mit Ihrer lokalen technischen Unterstützungsorganisation für Thermo Fisher Scientific San Jose Produkte in Verbindung. Si la sûreté d’un procédure est incertaine, avant de continuer, contacter le plus proche Service Clientèle pour les produits de Thermo Fisher Scientific San Jose. Cuando la certidumbre acerca de un procedimiento sea dudosa, antes de proseguir, pongase en contacto con la Oficina de Asistencia Tecnica local para los productos de Thermo Fisher Scientific San Jose. Quando e in dubbio la misura di sicurezza per una procedura, prima di continuare, si prega di mettersi in contatto con il Servizio di Assistenza Tecnica locale per i prodotti di Thermo Fisher Scientific San Jose. CAUTION Symbol CAUTION Electric Shock: This instrument uses high voltages that can cause personal injury. Before servicing, shut down the instrument and disconnect the instrument from line power. Keep the top cover on while operating the instrument. Do not remove protective covers from PCBs. Chemical: This instrument might contain hazardous chemicals. Wear gloves when handling toxic, carcinogenic, mutagenic, or corrosive or irritant chemicals. Use approved containers and proper procedures to dispose waste oil. Heat: Before servicing the instrument, allow any heated components to cool. Fire: Use care when operating the system in the presence of flammable gases. Eye Hazard: Eye damage could occur from splattered chemicals or flying particles. Wear safety glasses when handling chemicals or servicing the instrument. General Hazard: A hazard is present that is not included in the above categories. Also, this symbol appears on the instrument to refer the user to instructions in this manual. When the safety of a procedure is questionable, contact your local Technical Support organization for Thermo Fisher Scientific San Jose Products. C Contents Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .v Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Safety and Special Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Solvent and Gas Purity Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viii Service Philosophy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viii Level of Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viii Contacting Us . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ix Thermo Scientific Chapter 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Ionization Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Electron Ionization Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Chemical Ionization Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Ion Polarity Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Scan Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Q1MS and Q3MS Scan Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Product Scan Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Parent Scan Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Neutral Loss Scan Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Data-Dependent Scan Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Scan Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Full Scan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Selected Ion Monitoring (SIM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Selected Reaction Monitoring (SRM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Highly-Selective Reaction Monitoring (H-SRM) . . . . . . . . . . . . . . . . . . . . . 13 Intelligent Selected Reaction Monitoring (iSRM) . . . . . . . . . . . . . . . . . . . . . 13 Quantitation-Enhanced, Data-Dependent MS (QED MS) . . . . . . . . . . . . . . 14 AutoSIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Data Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Profile Data Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Centroid Data Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Mass/Charge Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Chapter 2 Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Autosampler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Gas Chromatograph . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 TSQ Quantum XLS and TSQ Quantum GC User Guide i Contents Direct Sample Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Transfer Line. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Mass Spectrometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Controls and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 EI CI Ion Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Inlet Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Ion Optics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Mass Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Ion Detection System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Vacuum System and Inlet Gasses Hardware . . . . . . . . . . . . . . . . . . . . . . . . . 41 Electronic Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Data System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Computer Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Data System / Mass Spectrometer / GC Interface . . . . . . . . . . . . . . . . . . . . . 48 Data System / Local Area Network Interface . . . . . . . . . . . . . . . . . . . . . . . . . 49 ii Chapter 3 System Shutdown, Startup, and Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 Shutting Down the System in an Emergency. . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Placing the System in Standby Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Shutting Down the System Completely. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Starting Up the System after a Complete Shutdown . . . . . . . . . . . . . . . . . . . . . 55 Restoring Power to the TSQ Quantum XLS or TSQ Quantum GC system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Starting Up the GC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Starting Up the Data System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Starting Up the Mass Spectrometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Starting Up the Autosampler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Setting Up Conditions for Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Resetting the Mass Spectrometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Resetting the Data System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Turning Off Selected Mass Spectrometer Components . . . . . . . . . . . . . . . . . . . 60 Chapter 4 Tuning and Calibrating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63 Displaying the FC-43 Mass Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Running Auto Tune and Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Saving the Tune and Calibration Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Chapter 5 Changing Ionization Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73 Removing the Ion Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Installing the Ion Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific Contents Thermo Scientific Chapter 6 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83 Cleaning Ion Source Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Cleaning Ion Volumes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Cleaning Lenses of the TSQ Quantum XLS Ion Source . . . . . . . . . . . . . . . . 88 Cleaning the Lenses of the TSQ Quantum GC Ion Source . . . . . . . . . . . . . . 95 Reinstalling the Ion Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 Replacing the Filament of the TSQ Quantum XLS Ion Source . . . . . . . . . . . . 102 Replacing the Filament of the TSQ Quantum GC Ion Source . . . . . . . . . . . . 105 Disassembling and Reassembling the TSQ Quantum XLS Ion Source Completely . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 Disassembling and Reassembling the TSQ Quantum GC Ion Source Completely . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 Cleaning Stainless Steel Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 Cleaning Non-Stainless Steel or Hybrid Part . . . . . . . . . . . . . . . . . . . . . . . . 115 Maintaining the Forepump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 Adding Calibration Compound. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 Replacing the Ball Valve Seal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Removing and Installing a GC Capillary Column . . . . . . . . . . . . . . . . . . . . . . 122 Removing a GC Capillary Column . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 Installing a GC Capillary Column. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 Chapter 7 Diagnostics and Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129 TSQ Quantum XLS System Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131 Communication Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131 Contamination Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 Filament and Lens Control Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135 Heated Zone Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 High Vacuum Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 Linearity Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 Power Supply Issues. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 Sensitivity Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 Stability Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 Tuning Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 Replacing a Fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 Replacing PCBs and Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146 Appendix 8 Using the Direct Sample Probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .147 Creating an Instrument Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 Creating a Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 Preparing the Probe and Inlet Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 Preparing the Mass Spectrometer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 Running the Sequence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 Examining the Raw Data in Qual Browser . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 Removing the Probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158 TSQ Quantum XLS and TSQ Quantum GC User Guide iii Contents Chapter 9 Replaceable Parts and Consumables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161 Accessory Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 Chemicals Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163 iv TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific P Preface The Thermo Scientific TSQ Quantum XLS™ and TSQ Quantum GC™ systems are members of the TSQ™ Quantum family of mass spectrometers. This TSQ Quantum XLS and TSQ Quantum GC User Guide contains a description of the modes of operation and principle hardware components of your TSQ Quantum XLS or TSQ Quantum GC system. In addition, this manual provides step-by-step instructions for cleaning and maintaining your mass spectrometer. Related Documentation In addition to this manual, Thermo Fisher provides the following for the TSQ Quantum XLS and TSQ Quantum GC: • Preinstallation Requirements Guide • Help available from within the software Safety and Special Notices Make sure you follow the precautionary statements presented in this guide. The safety and other special notices appear in boxes. Safety and special notices include the following: CAUTION Highlights hazards to humans, property, or the environment. Each CAUTION notice is accompanied by an appropriate CAUTION symbol. IMPORTANT Highlights information necessary to prevent damage to software, loss of data, or invalid test results; or might contain information that is critical for optimal performance of the system. Note Highlights information of general interest. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide v Preface Tip Highlights helpful information that can make a task easier. vi TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific Preface Safety Precautions Observe the following safety precautions when you operate or perform service on the mass spectrometer. CAUTION Do Not Perform Any Servicing Other Than That Contained in the TSQ Quantum XLS and TSQ Quantum GC User Guide. To avoid personal injury or damage to the instrument, do not perform any servicing other than that contained in the TSQ Quantum XLS and TSQ Quantum GC User Guide or related manuals unless you are authorized to do so. CAUTION Shut Down the Mass Spectrometer and Disconnect It From Line Power Before You Service It. High voltages capable of causing personal injury are used in the instrument. Some maintenance procedures require that the mass spectrometer be shut down and disconnected from line power before service is performed. Do not operate the mass spectrometer with the top or side covers off. Do not remove protective covers from PCBs. CAUTION Respect Heated Zones. Treat heated zones with respect. The ion source and transfer line might be very hot and might cause severe burns if they are touched. Allow heated components to cool before you service them. CAUTION Provide and Adequate Fume Exhaust System. It is your responsibility to provide an adequate fume exhaust system. Samples and solvents that are introduced into the mass spectrometer will eventually be exhausted from the forepump. Therefore, the forepump should be connected to a fume exhaust system. Consult local regulations for the proper method of exhausting the fumes from your system. CAUTION Use Care When Changing Vacuum Pump Oil. Treat drained vacuum pump oil and pump oil reservoirs with care. Hazardous compounds introduced into the system might have become dissolved in the pump oil. Always use approved containers and procedures for disposing of waste oil. Whenever a pump has been operating on a system used for the analysis of toxic, carcinogenic, mutagenic, or corrosive/irritant chemicals, the pump must be decontaminated by the user and certified to be free of contamination before repairs or adjustments are made by a Thermo Fisher Scientific San Jose Customer Support Engineer or before it is sent back to the factory for service. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide vii Preface Solvent and Gas Purity Requirements Use the highest purity solvents available. The TSQ Quantum XLS and TSQ Quantum GC mass spectrometers are extremely sensitive to solvent impurities. Liquid chromatography grade is the minimum acceptable purity. Higher grade solvents are preferred. Distilled water is recommended. Deionized water contains chemicals and is not recommended. For a wide variety of solvents and consumables, visit www.FisherLCMS.com. The TSQ Quantum XLS and TSQ Quantum GC mass spectrometers use argon as a collision gas. The argon must be high purity (99.995%). The required gas pressure is 135 ± 70 kPa (20 ± 10 psig). Thermo Fisher has found that particulate filters are often contaminated and are therefore not recommended. Service Philosophy Servicing the TSQ Quantum XLS and TSQ Quantum GC systems consists of performing procedures required to maintain system performance standards, prevent system failure, restore the system to an operating condition, or all of the above. Routine and preventive maintenance procedures are documented in this manual. The user is responsible for routine and preventive maintenance during and after the warranty period. Regular maintenance increases the life of the system, maximizes the up-time of your system, and allows you to achieve optimum system performance. Only a Thermo Fisher Scientific Customer Support Engineer can perform services not described in this manual. Level of Repair Thermo Fisher Scientific’s service philosophy for the TSQ Quantum XLS and TSQ Quantum GC systems calls for troubleshooting to the lowest part, assembly, printed circuit board (PCB), or module listed in the “Replaceable Parts” chapter of this manual. For mechanical failures: A mechanical assembly typically is to be repaired to the level of the smallest item listed in the “Replaceable Parts” chapter of this manual. For electronic failures: PCBs are not repaired to the component level except in certain cases of fuses, relays, and so on. When these exceptions occur, component information can be found in the “Replaceable Parts” chapter. viii TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific Preface Contacting Us There are several ways to contact Thermo Fisher Scientific. Y To contact Technical Support Phone Fax E-mail Knowledge base 800-685-9535 561-688-8736 [email protected] www.thermokb.com Find software updates and utilities to download at www.mssupport.thermo.com. Y To contact Customer Service for ordering information Phone Fax Web site 800-532-4752 561-688-8731 www.thermo.com/finnigan Y To suggest changes to documentation or to Help • Fill out a reader survey online at www.thermo.com/lcms-techpubs. • Send an e-mail message to the Technical Publications Editor at [email protected] Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide ix 1 Introduction The TSQ Quantum XLS™ and TSQ Quantum GC™ are members of the TSQ™ Quantum family of Thermo Scientific mass spectrometers. The TSQ Quantum XLS and the TSQ Quantum GC are advanced analytical instrument that includes a mass spectrometer, liquid chromatograph, and the Xcalibur™ data system. See Figure 1. Contents • Ionization Modes • Ion Polarity Modes • Scan Modes • Scan Types • Data Types • Mass/Charge Range In a typical analysis, an autosampler (AS) introduces a sample into the gas chromatograph (GC). The GC separates the sample into its various components. The components elute from the GC and pass into the mass spectrometer where they are analyzed. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 1 1 Introduction Figure 1. TSQ Quantum GC mass spectrometer, TriPlus autosampler, and TRACE GC Ultra gas chromatograph The TSQ Quantum XLS and TSQ Quantum GC mass spectrometers include an electron ionization/chemical ionization (EI/CI) ion source, ion optics, a triple-stage mass analyzer, and an ion detection system, all of which are enclosed in a vacuum manifold. Ionization of the sample takes place in the ion source. The specific process used to ionize the sample is known as the ionization mode. The ion optics transmit the ions produced in the ion source into the mass analyzer, where they are filtered according to their mass-to-charge ratio. The polarity of the potentials applied to the lenses in the ion source and ion optics determines whether positively charged ions or negatively charged ions are transmitted to the mass analyzer. You can configure the mass spectrometer to analyze positively or negatively charged ions (called the positive or negative ion polarity mode). The mass spectrometer’s triple-stage mass analyzer performs either one or two stages of mass analysis: • The mass spectrometer is operated as a conventional mass spectrometer with one stage of mass analysis. The ion source ionizes the sample and the ion products are subjected to mass analysis in the first rod assembly. The second and third rod assemblies transmit the resulting mass-selected ions to the ion detection system.1 2 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 1 Introduction Ionization Modes • The mass spectrometer is operated as a tandem mass spectrometer with two stages of mass analysis. The ion source ionizes the sample and the ion products are mass analyzed by the first rod assembly. In this case, however, mass-selected ions exiting the first rod assembly collide with an inert gas in the second rod assembly and fragment to produce a set of ions known as product ions. (A chamber called the collision cell surrounds the second rod assembly. The collision cell can be pressurized with an inert gas.) The product ions undergo further mass analysis in the third rod assembly to detect selected ions. Two stages of mass analysis yield far greater chemical specificity than a single stage can achieve, because of the system’s ability to select and determine two discrete but directly related sets of masses. In a first stage of mass analysis the mass spectrometer can be used to elucidate the structures of pure organic compounds and the structures of the components within mixtures. Furthermore, in a second stage of mass analysis, the mass spectrometer can fragment and separate each ionic fragment of a molecule formed in the ion source to build up an entire structure for the molecule, piece by piece. Thus, TSQ Quantum XLS and TSQ Quantum GC systems make investigating all pathways for the formation and fragmentation of each ion in the mass spectrum possible. The two stages of mass analysis, with resultant reduction of chemical noise in the final mass spectrum, allow for very selective and sensitive analysis. Each sequence of single or triple-stage mass analysis of the ions is called a scan. The mass spectrometer uses several different scan modes and different scan types to filter, fragment, or transmit ions in the mass analyzer. Along with the ionization and ion polarity modes, the ability to vary the scan mode and scan type affords the user great flexibility in the instrumentation for solving complex analytical problems. Ionization Modes The specific process used to ionize the analyte is referred to as the ionization mode. You can operate the TSQ Quantum XLS and TSQ Quantum GC mass spectrometers in either of two ionization modes: • Electron ionization mode • Chemical ionization mode 1 Thermo Scientific The instrument can also be used as a single-stage mass spectrometer by transmitting the ions through the first and second rod assemblies followed by mass analysis in the third rod assembly. TSQ Quantum XLS and TSQ Quantum GC User Guide 3 1 Introduction Ionization Modes Electron Ionization Mode In electron ionization (EI) mode, electrons are emitted by a heated, wire filament that has electric current running through it, by thermionic emission. The filament and its reflector are typically maintained at a -70 V potential relative to the ion source block. This potential accelerates the electrons through the ionization space, called the ion volume. These energetic electrons interact with neutral, gas-phase analyte molecules present in the ion volume and cause the analyte to lose an electron and produce a radical cation: M + e - --> M+ + 2e Frequently, numerous cleavage reactions give rise to fragment ions, which provide structural information about the analyte. EI positive-ion mode is the only commonly used EI mode. Chemical Ionization Mode In chemical ionization (CI) mode, ionization of the sample molecules is a multi-step process: 1. Reagent gas is introduced into the CI ion volume at a flow (for methane) of about 2 mL/min, along with sample vapors typically present at partial pressures of less than one-thousandth that of the reagent gas. 2. The energetic (typically 100 eV) electrons emitted by the heated filament interact to ionize the reagent gas and form a plasma. This reaction also produces thermal electrons. 3. Reagent gas ions react with reagent gas molecules to form a variety of secondary ions that are stable with respect to further reaction with reagent gas. For example, for methane: CH4 + e - ----> CH4+. + 2e CH4 + e - ----> CH3+ + e - + HCH4+. + CH4 ----> CH5+ +CH3. CH3+ + CH4 ----> C2H5+ + H2 4. Positive sample ions are formed by one of the following: • The transfer of a proton from a secondary reagent gas ion to a sample molecule • The abstraction of an electron by a reagent gas ion • An ion association reaction in which an adduct ion is formed between a reagent gas ion and a sample molecule In methane positive ion mode CI, the relevant peaks observed are MH+, [M+CH5]+, and [M+C2H5]+; but mainly MH+. 4 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 1 Introduction Ion Polarity Modes In isobutane positive ion mode CI, the main peak observed is MH+. In ammonia positive ion mode CI, the main peaks observed are MH+ and [M+NH4]+. Negative sample ions are most commonly formed by one of the following: • Sample molecules capture the secondary thermal electrons present in the ion source • Electron transfer from ionized reagent gas (e.g. NH2-) • Proton abstraction Molecular ions observed in negative ion chemical ionization mass spectra are usually M- or [M-H]-. Ion Polarity Modes You can operate the TSQ Quantum XLS and TSQ Quantum GC mass spectrometers in either of two ion polarity modes: positive or negative. Both positively charged and negatively charged ions form in the ion source of the mass spectrometer. The mass spectrometer controls whether positive ions or negative ions are transmitted to the mass analyzer for mass analysis by changing the polarity of the potentials applied to the ion source and ion optics. The ion optics deliver the ions produced in the ion source, in a collimated beam, to the mass analyzer. The mass spectrometer can switch between positive and negative polarity modes in under 95 ms. The information obtained from a positive-ion mass spectrum is different from and complementary to the information from a negative-ion spectrum. Thus, the ability to obtain both positive-ion and negative-ion mass spectra aids you in the qualitative analysis of your sample. You can choose the ion polarity mode and ionization mode to obtain maximum sensitivity for the particular analyte of interest. Scan Modes You can operate the TSQ Quantum XLS and TSQ Quantum GC mass spectrometers in a variety of scan modes. The most commonly used scan modes can be divided into two categories: single mass spectrometry (MS) scan modes and MS/MS scan modes. The scan modes in each category are as follows: • MS scan modes: Q1MS and Q3MS scan modes • MS/MS scan modes: Product scan mode, Parent scan mode, Neutral Loss scan mode • Data-dependent scan mode The scan modes that can be employed depend on the number and type of rod assemblies and the voltages applied to the rod assemblies. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 5 1 Introduction Scan Modes The mass analyzer or the mass spectrometer has three rod assemblies.2 The first and third rod assemblies, Q1 and Q3, are quadrupoles, and the second rod assembly, Q2, is a square-profile quadrupole. Rod assemblies can operate in either of two capacities: • As ion transmission devices • As mass analyzers If only RF voltage is applied, a rod assembly serves as an ion transmission device that passes all ions within a large range of mass-to-charge ratios (that is, virtually all ions present). When you apply both RF and dc voltages to a rod assembly, the separation of ions of different mass-to-charge ratios occurs. This separation allows the rod assembly to serve as a mass analyzer. On the TSQ Quantum XLS and TSQ Quantum GC mass spectrometers, the quadrupole rod assemblies can operate with rf and dc voltages or with only rf voltage. That is, Q1 and Q3 can act either as mass analyzers or ion transmission devices. The Q2 rod assembly operates exclusively with rf voltage. Thus, Q2 is always an ion transmission device. Surrounding Q2 is a collision cell where fragmentation can take place if the argon collision gas is present in the cell. For a summary of how the rod assemblies function in several of the major scan modes, see Table 1. . Table 1. Summary of scan modes Scan mode Q1 quadrupole Q2 collision cell Q3 quadrupole Q1MS Scana Pass all ionsb Pass all ions Q3MS Pass all ions Pass all ions Scan Product Setd Fragment ionsc, then pass all fragments Scan Parent Scan Fragment ions, then pass all fragments Set Neutral Loss Scan Fragment ions, then pass all fragments Scan a Scan = full scan or transmission of selected ions Pass all ions or fragments = pass ions or fragments within a wide range of mass-to-charge ratios c Fragment ions = collisions with argon gas cause ions to fragment d Set = set to pass ions of a single mass-to-charge ratio or a set of mass-to-charge ratios b 2A rod assembly is a regular array of metal rods. Refer to “Mass Analyzer” on page 32 for a discussion of the rod assemblies used on the TSQ Quantum XLS instrument. 6 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 1 Introduction Scan Modes Q1MS and Q3MS Scan Modes In the Q1MS and Q3MS scan modes, only one stage of mass analysis is performed. The mass spectrum obtained is equivalent to the mass spectrum obtained from an instrument with a single mass analyzer. In the one stage of analysis, ions formed in the ion source enter the analyzer assembly. One of the mass analyzers (Q1 or Q3) is scanned to obtain a complete mass spectrum. The other rod assemblies (Q2 and Q3, or Q1 and Q2, respectively) act as ion transmission devices. In the Q1MS scan mode, Q1 is used as the mass analyzer; in the Q3MS scan mode, Q3 is used as the mass analyzer. Product Scan Mode Product scan mode performs two stages of analysis. In the first stage, ions formed in the ion source enter Q1, which is set to transmit ions of one mass-to-charge ratio. Ions selected by this first stage of mass analysis are called parent ions. (As a result, Q1 is referred to as the parent mass analyzer, and the mass-to-charge ratio of ions transmitted by the parent mass analyzer is referred to as the parent set mass.) Parent ions selected by Q1 then enter Q2, which is surrounded by the collision cell. Note When referring to the first, second, and third rod assemblies as pieces of hardware, it is convenient to call them Q1, Q2, and Q3, respectively. However, when discussing their function in MS/MS scan modes, it often adds clarity to refer to them as the parent mass analyzer, collision cell (ion transmission device surrounded by the collision cell), and product mass analyzer, respectively. In the second stage of analysis, ions in the collision cell can fragment further to produce product ions. Two processes produce product ions: by unimolecular decomposition of metastable ions or by interaction with argon collision gas present in the collision cell. This latter step is known as collision-induced dissociation (CID). Ions formed in the collision cell enter Q3 (the product mass analyzer) for the second stage of mass analysis. Q3 is scanned to obtain a mass spectrum that shows the product ions produced from the fragmentation of the selected parent ion. A mass spectrum obtained in the Product scan mode (product mass spectrum) is the mass spectrum of a selected parent ion. The Product scan mode is illustrated in Figure 2. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 7 1 Introduction Scan Modes Figure 2. Illustration of Product scan mode Q1 Set Q2 RF Only + Ar Q3 Scanning Q3 m/z Parent Scan Mode The Parent scan mode also uses two stages of analysis. In the first stage, ions formed in the ion source are introduced into the parent mass analyzer, which is scanned to transmit parent ions sequentially into the collision cell. In the second stage of analysis, in the collision cell, parent ions can fragment to produce product ions by unimolecular decomposition of metastable ions or by collision-induced dissociation. Ions formed in the collision cell enter the product mass analyzer, which transmits a selected product ion. (The product set mass is the mass-to-charge ratio of ions transmitted by the product mass analyzer.) The resultant spectrum shows all the parent ions that fragment to produce the selected product ion. Note that for a mass spectrum obtained in the Parent scan mode (parent mass spectrum), data for the mass-to-charge ratio axis are obtained from Q1 (the parent ions), whereas data for the ion intensity axis are obtained from Q3 (from monitoring the product ion). The Parent scan mode is illustrated in Figure 3. 8 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 1 Figure 3. Introduction Scan Modes Illustration of the Parent scan mode Q1 Scanning Q2 RF Only + Ar Q3 Set Q1 m/z Experiments that employ the parent scan mode (parent experiments) can be used in structure and fragmentation studies as well as in survey analyses of mixtures. In general, parent experiments detect all compounds that decompose to a common fragment. The experiments are useful for the rapid detection of a series of structural homologs that have a common fragment ion (for example, m/z 149 for the phthalates). Neutral Loss Scan Modes In the Neutral Loss scan mode, the two mass analyzers (Q1 and Q3) are linked together so that they are scanned at the same rate over mass ranges of the same width. The respective mass ranges, however, are offset by a selected mass, such that the product mass analyzer scans a selected number of mass units lower than the parent mass analyzer. Thus, in the Neutral Loss scan mode, there are two stages of mass analysis. In the first stage, the parent mass analyzer separates ions formed in the ion source by mass-to-charge ratio. Then the ions are introduced sequentially into the collision cell. In the second stage of analysis, ions admitted to the collision cell can fragment further by metastable ion decomposition or by CID to produce product ions. The product mass analyzer then separates these product ions by mass-to-charge ratio. Neutral Loss scan mode is illustrated in Figure 4. Examples of compounds with a common neutral loss fragment appear in Figure 5. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 9 1 Introduction Scan Modes To detect an ion, between the time the ion leaves Q1 and enters Q3, it must lose a neutral moiety whose mass (the neutral loss mass) is equal to the difference in the mass ranges being scanned by the two mass analyzers. Thus, a neutral loss mass spectrum is a spectrum that shows all the parent ions that lose a neutral species of a selected mass. Note that a neutral gain (or association) experiment can also be performed in which the mass range scanned by Q3 is offset by a selected mass above the mass range scanned by Q1. For a neutral loss (or neutral gain) mass spectrum, as for a parent mass spectrum, data for the mass-to-charge ratio axis are obtained from Q1 (the parent ion), whereas data for the ion intensity axis are obtained from Q3 (the product ion being monitored). Experiments that use the Neutral Loss scan mode (neutral loss experiments) are useful when a large number of compounds are being surveyed for common functionality. Neutral moieties are frequently lost from substituent functional groups (for example, CO2 from carboxylic acids, CO from aldehydes, HX from halides, and H2O from alcohols). Figure 4. Illustration of the Neutral Loss scan mode Q2 Q1 Scanning R F O nly + A r Q3 = Q1 - Δ Q1 m/z 10 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 1 Figure 5. Introduction Scan Modes Examples of compounds with a common neutral-loss fragment NH2 N N H2 N N HO N N N N H2 N N N H2 N N N Data-Dependent Scan Mode The TSQ Quantum XLS and TSQ Quantum GC mass spectrometers use the information in a data-dependent scan mode experiment to make automatic decisions about the next step of the experiment without input from a user. In data-dependent scan mode you specify criteria to select one or more ions of interest on which to perform subsequent scans, such as MS/MS. You can approach the setup of data-dependent experiments in either of two ways: • If you have some idea of what the parent ion is, or if you expect a certain kind of parent ion, you can set up a list of possible parent ions. Then, when one of the parent ions you specified is detected, you can acquire product spectra and analyze the information. Conversely, you can also set up a list of ions that you do not want selected for fragmentation. • If you have little information about your compound, you can set up the parameters of a data-dependent experiment so that if the intensity of the ion signal is above a specified threshold, the mass spectrometer generates product spectra. Later, you can decide if the information is useful. Because a data-dependent scan needs to use a target ion from a previous scan, the first scan event cannot be a data-dependent scan. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 11 1 Introduction Scan Types Scan Types You can operate the TSQ Quantum XLS and TSQ Quantum GC systems with a variety of scan types. The most common scan types are as follows: • Full Scan • Selected Ion Monitoring (SIM) • Selected Reaction Monitoring (SRM) • Intelligent Selected Reaction Monitoring (iSRM) • Quantitation-Enhanced, Data-Dependent MS (QED MS) • AutoSIM Full Scan The full-scan scan type provides a full mass spectrum of each analyte. With full scan, the scanning mass analyzer is scanned from the first mass to the last mass, without interruption, in a given scan time. Full-scan experiments are used to determine or confirm the identity of unknown compounds or the identity of each component in a mixture of unknown compounds. (Generally, a full mass spectrum is needed to determine the identity of an unknown compound.) The full-scan scan type gives you more information about an analyte than does SIM, but a full scan does not yield the sensitivity that the other two scan types can achieve. With full scan, you spend less time monitoring the signal for each ion than you do in SIM or SRM. Full scan provides greater information but lower sensitivity than the other two scan types. To use the SIM or SRM, you need to know what ions or reactions you are looking for before you can perform an experiment with these scan types. Thus, you might use a full scan for SIM to determine the identity of an analyte and to obtain its mass spectrum and a full scan for SRM to determine the mass spectrum and product mass spectra for parent ions of interest. Then, you might use SIM or SRM to do routine quantitative analysis of the compound. Selected Ion Monitoring (SIM) Selected ion monitoring (SIM) monitors a particular ion or set of ions. SIM experiments are useful in detecting small quantities of a target compound in a complex mixture when you know the mass spectrum of the target compound. Thus, SIM is useful in trace analysis and in the rapid screening of a large number of samples for a target compound. 12 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 1 Introduction Scan Types Because SIM monitors only a few ions, it can provide lower detection limits and greater speed than the full-scan modes. SIM achieves lower detection limits because more time is spent monitoring significant ions that are known to occur in the mass spectrum of the target analyte. SIM can achieve greater speed because it monitors only a few ions of interest; SIM does not monitor regions of the spectrum that are empty or have no ions of interest. SIM can improve the detection limit and decrease analysis time, but it can also reduce specificity. Because SIM monitors only specific ions, any compound that fragments to produce those ions will appear to be the target compound. The result could be a false positive. Selected Reaction Monitoring (SRM) Selected reaction monitoring (SRM) monitors a particular reaction or set of reactions, such as the fragmentation of an ion or the loss of a neutral moiety. SRM monitors a limited number of parent/product-ion pairs. In product-type experiments, a parent ion is selected as usual, but generally only one product ion is monitored. SRM experiments are normally conducted with the product scan mode. As does SIM, SRM provides for the very rapid analysis of trace components in complex mixtures. However, because SRM selects two sets of ions, it obtains specificity that is much greater than what SIM can obtain. Any interfering compound would not only have to form an ion source product (parent ion) of the same mass-to-charge ratio as the selected parent ion from the target compound, but that parent ion would also have to fragment to form a product ion of the same mass-to-charge ratio as the selected product ion from the target compound. Highly-Selective Reaction Monitoring (H-SRM) Highly-selective reaction monitoring (H-SRM) is SRM performed at higher resolution (0.4 u FWHM versus 0.7 u FWHM for SRM). Intelligent Selected Reaction Monitoring (iSRM) In intelligent selected reaction monitoring (iSRM) experiments, the TSQ Quantum XLS and TSQ Quantum GC mass spectrometers perform multiple “primary” selected reaction monitoring (SRM) scans for each analyte (parent ion) of interest. The mass spectrometer uses for quantification the sum of the intensities of an analyte’s primary SRM scans. You specify a trigger threshold for each primary SRM scan. If the intensities of all the listed primary SRM reactions for an analyte are above their trigger thresholds, and if all these scans are within a specified retention time window, then the mass spectrometer performs “secondary” SRM scans to confirm the identity of the analyte. The maximum number of secondary SRM reactions is 12400. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 13 1 Introduction Data Types The mass spectrometer uses reference SRM scans to adjust the acquisition time window of subsequent SRM scans. It uses the time difference between the expected and observed retention times of reference SRM reactions to correct the retention times that it uses to make procedural decisions. The mass spectrometer still records data with the true retention times. You should specify two to four reference reactions spaced throughout the LC run. The mass spectrometer uses the preceeding two retention time corrections to calculate a piecewise linear retention time correction for the primary SRM scans that follow. As with primary SRM scans, reference SRM scans may trigger secondary SRM scans. The maximum number of primary plus reference SRM transitions is 3600. Quantitation-Enhanced, Data-Dependent MS (QED MS) Quantitation-enhanced, data-dependent MS (QED MS) scan type provides simultaneous quantitation (SRM) and structural confirmation (full-scan MS/MS product ion spectra). If the intensity of an SRM reaction that you specify for a parent ion is above its trigger threshold, the mass spectrometer performs a full-scan MS/MS product ion scan to confirm the identity of the analyte. AutoSIM In the scan type known as AutoSIM, the mass spectrometer automatically selects the most intense masses (m/z values) in a survey scan, builds a SIM scan list for them, and then acquires and records ion current at only these selected masses. AutoSIM scans can be performed on any full scan in any scan mode, but not on data-dependent scans. Data Types You can acquire and display mass spectral data (intensity versus mass-to-charge ratio) with the TSQ Quantum XLS and TSQ Quantum GC mass spectrometers in one of two data types: • Profile data type • Centroid data type Profile Data Type In the profile data type, you can see the shape of the peaks in the mass spectrum. Each atomic mass unit is divided into many sampling intervals. The intensity of the ion current is determined at each of the sampling intervals. The profile data type displays the intensity at each sampling interval with the intensities connected by a continuous line. In general, use the profile scan data type when you tune and calibrate the mass spectrometer so that you can easily see and measure mass resolution. 14 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 1 Introduction Mass/Charge Range Centroid Data Type The centroid data type displays the mass spectrum as a bar graph and sums the intensities of each set of multiple sampling intervals. This sum is displayed versus the integral center of mass of the sampling intervals. In general, use the centroid scan data type for data acquisition for faster scan speed. Data processing is also much faster for centroid data. Mass/Charge Range The TSQ Quantum XLS and TSQ Quantum GC mass spectrometers can operate in a mass/charge range of 10 to 3000 Da. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 15 2 Functional Description This chapter describes the principal components of the TSQ Quantum XLS and TSQ Quantum GC systems and their respective functions. Contents • Autosampler (optional) • Gas Chromatograph • Direct Sample Probes (optional) • Transfer Line • Mass Spectrometer • Data System A functional block diagram of the TSQ Quantum XLS or TSQ Quantum GC system is shown in Figure 6. A sample transfer line connects the gas chromatograph (GC) to the mass spectrometer. The autosampler and GC are installed on the left side of the mass spectrometer. In analysis by GC/MS, a sample is injected into a GC column. The sample then separates into its various components. The components elute from the GC column and pass through the transfer line into the mass spectrometer where they are analyzed. You can also use a direct sample probe to introduce sample into the mass spectrometer. Electron ionization (EI) or chemical ionization (CI) ionize sample molecules upon entering the mass spectrometer. The ion optics focus and accelerate the resulting sample ions into the mass analyzer where they are filtered according to their mass-to-charge ratios. An ion detection system then produces a signal proportional to the number of ions detected. The system electronics receive and amplify the ion current signal from the ion detection system. That signal is then passed on to the data system for further processing, storage, and display. The data system provides the primary mass spectrometer user interface. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 17 2 Functional Description Autosampler Figure 6. Functional block diagram of the TSQ Quantum XLS or TSQ Quantum GC system Sample flow Electrical connection Mass spectrometer Data system Autosampler (Optional) Printer (optional) Gas chromatograph Ion source Ion optics Mass analyzer Ion detection system Transfer line Vacuum system Instrument control electronic assemblies Personal computer Video monitor Autosampler The (optional) Thermo Scientific TriPlus autosampler is used to inject samples automatically into the GC inlet. With an autosampler, you can automate your GC/MS/MS analyses. The TriPlus autosampler is shown in Figure 1 on page 2. Autosampler Start/Stop signals with the mass spectrometer are provided by contact closure. You configure the TriPlus autosampler from the data system computer. Select the TriPlus instrument button in the Instrument Configuration window, which is available by choosing Start > All Programs > Xcalibur > Instrument Configuration. Refer to Xcalibur Help for a description of TriPlus configuration options. You also use the data system to set up the TriPlus autosampler to inject samples. Choose Start > All Programs > Xcalibur > Xcalibur and click Instrument Setup to open the Instrument Setup window. Then, click the TriPlus icon to open the TriPlus Autosampler page. Refer to the Help for instructions on running the TriPlus autosampler. Refer to the documentation provided with the autosampler for maintenance procedures. 18 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 2 Functional Description Gas Chromatograph Gas Chromatograph The Thermo Scientific TRACE GC Ultra gas chromatograph (GC)) separates a sample mixture into its chemical components by gas chromatography. In gas chromatography, the sample mixture is partitioned between a solid stationary phase and a mobile gas. The stationary phase is adhered to the inside of a small-diameter glass tube: the capillary column. The molecular structure of each component of the mixture determines in which order each component elutes from the GC and enters the mass spectrometer. The TRACE GC Ultra gas chromatograph is shown in Figure 1 on page 2. Gas chromatography is widely used in analytical chemistry, though the high temperatures used in GC make it unsuitable for high molecular weight biopolymers, frequently encountered in biochemistry. It is well suited for use in the petrochemical, environmental monitoring, and industrial chemical fields. It is also used extensively in chemistry research. You configure the TRACE GC Ultra gas chromatograph from the data system computer. Select the TRACE GC Ultra instrument button in the Instrument Configuration window, which is available by choosing Start > All Programs > Xcalibur > Instrument Configuration. Refer to Xcalibur Help for a description of TRACE GC Ultra configuration options. The TSQ Quantum XLS and TSQ Quantum GC data system computers can directly control the TRACE GC Ultra. Choose Start > Programs > Xcalibur > Xcalibur and click Instrument Setup to open the Instrument Setup window. Click the TRACE GC Ultra icon to open the TRACE GC Ultra page. Refer to the Help for instructions for operating the TRACE GC Ultra. Front-panel (keypad) operation of the GC and maintenance procedures for the GC are described in the documentation provided with the GC. To replace the GC capillary column, see “Removing and Installing a GC Capillary Column” on page 122. Direct Sample Probes With the (optional) direct sample probes you can introduce compounds directly into the ion source without GC column separation. See Figure 7. The direct sample probes are ideal for qualitative or semi-quantitative analysis of materials that don't require a GC column separation, or are difficult, if not impossible, to elute chromatographically, such as solids. The direct sample probes introduce samples directly into the ion source via a vacuum interlock. A single controller box (Figure 7) with interchangeable probe tools makes it easy to select the best method of sample introduction. The direct sample probe system includes two probe tools: • Direct exposure probe • Direct insertion probe Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 19 2 Functional Description Transfer Line The direct exposure probe (DEP) has a heated filament that rapidly vaporizes liquids or solutions. The DEP is ideal for rapid molecular weight confirmation of liquids or solids dissolved in a suitable solvent. The DEP can vaporize compounds with a high boiling point. The direct insertion probe (DIP) has a temperature-controlled, heated capillary tube that slowly vaporizes solid samples. You can use the DIP for rapid analysis of solids or trace components in solid matrices, such as forensic samples or tissue. Figure 7. Direct sample probe and controller Transfer Line The transfer line is the interface between the GC and mass spectrometer. The transfer line heats the capillary column as it passes from the GC into the ion source in the mass spectrometer. This prevents the sample from condensing. The transfer line includes an inlet for calibration gas and chemical ionization gas. 20 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 2 Figure 8. Functional Description Mass Spectrometer Transfer line GC end Inlet for calibration gas and CI gas Mass spectrometer ion source end Mass Spectrometer The TSQ Quantum XLS mass spectrometer provides sample ionization and mass analysis of samples introduced from a gas chromatograph or direct insertion probe. The mass spectrometer uses a triple-quadrupole mass analyzer with an ion source external to the mass analyzer. Several important features of the TSQ Quantum XLS and TSQ Quantum GC mass spectrometers are as follows: • High sensitivity and resolution • m/z 10 to 3000 mass range • EI and CI ionization modes • Positive and negative ion polarity modes • MS and MS/MS scan modes • Full-scan, SIM, SRM, iSRM, QED MS, AutoSIM, and data-dependent scan types The mass spectrometer includes the following components: • Controls and Indicators • EI CI Ion Source • Ion Optics • Mass Analyzer Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 21 2 Functional Description Mass Spectrometer • Ion Detection System • Vacuum System and Inlet Gasses Hardware • Electronic Assemblies • Data System Controls and Indicators Five light-emitting diodes (LEDs) are located at the upper right side of the front panel of the mass spectrometer. See Figure 9. The Power LED illuminates green whenever power is supplied to the vacuum system and electronic assemblies of the mass spectrometer. The Vacuum LED illuminates yellow when the turbomolecular pump is nearly at speed (80% of its operating speed of 750 MHz) and it is safe to turn on the ion gauge. The Vacuum LED is off if the turbomolecular pump is not at speed. The Vacuum LED illuminates green whenever the pressure in the analyzer chamber, as measured by the ion gauge, is at or below the value required to enable high voltages to the mass analyzer. See Table 2. Figure 9. Front panel LEDs of the mass spectrometer Power Vacuum System Communication Scan Table 2. Maximum allowed pressure to turn on high voltages Carrier gas Ar collision gas Maximum pressure (Torr) He Off 6 × 10-6 He On 5 × 10-5 H2 Off 5 × 10-5 H2 On 1 × 10-4 The Communication LED illuminates yellow when the mass spectrometer and the data system are trying to establish a communication link. The Communication LED illuminates green when the Ethernet communication link between the mass spectrometer and the data system has been made. 22 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 2 Functional Description Mass Spectrometer The System LED illuminates yellow whenever the mass spectrometer is in Standby—that is, high voltage is not supplied to the ion source, mass analyzer, or ion detection system, but the mass spectrometer power is on. The System LED illuminates green whenever the high voltage is enabled and the system is in the On state. High voltage is enabled if the pressure of the analyzer chamber is below the values listed in Table 2. The Scan LED flashes blue whenever the mass spectrometer is on and is scanning ions. The System Power Off button, located on the front of the electronics module, turns off power to the mass spectrometer, gas chromatograph, and autosampler. See Figure 10. You must use the main power circuit breaker, located on the back of the electronics module, to restore power to the mass spectrometer, gas chromatograph, and autosampler. CAUTION In an emergency, to shut off all power to the mass spectrometer, gas chromatograph, and autosampler, press the System Power Off button located at the front of the instrument. Figure 10. Front panel System Power Off button System System Power Off The main power circuit breaker switch (labeled Main Power) is located on the power panel at the back of the electronics module. See Figure 11. In the Off (O) position, the circuit breaker removes all power to the mass spectrometer, gas chromatograph, and autosampler. In the On (|) position, power is supplied to the mass spectrometer, gas chromatograph, and autosampler. In the standard operational mode, the circuit breaker is kept in the On (|) position. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 23 2 Functional Description Mass Spectrometer Figure 11. Rear power panel of the electronics module GC Power Out Power In Quantum Power Out A/S Power Out ! ! V~230 Hz, 30A MAX V~230 50/60 Hz, 16A MAX V~230 50/60 Hz, 10A MAX V~230 50/60 Hz, 2A MAX The mass spectrometer main power circuit breaker switch (labeled Main Power) is located on the mass spectrometer power panel in the lower corner of the right-side panel of the mass spectrometer. See Figure 12. In the Off position, the circuit breaker removes all power to the mass spectrometer, including the vacuum pumps. In the On position, power is supplied to the mass spectrometer. In the standard operational mode, the circuit breaker is kept in the On position. The electronics service switch (labeled Electronics) is located next to the main power circuit breaker on the mass spectrometer power panel (Figure 12). In the Service Mode position the switch removes power to all components of the mass spectrometer other than the vacuum system. The Operating Mode position supplies power to all non-vacuum system components of the mass spectrometer. The vacuum service switch (labeled Vacuum) is located next to the electronics service switch on the mass spectrometer power panel (Figure 12). In the Service Mode position the switch removes power to all components of the vacuum system, including the forepump, turbomolecular pump, and turbomolecular pump controller. The switch in the Operating Mode position supplies power to all vacuum system components of the mass spectrometer. The System Reset button is also located on the mass spectrometer power panel. Pressing the System Reset button takes the 5 V logic to ground and causes the embedded computer on the System Control PCB to reboot. The mass spectrometer software is then reloaded from the data system. See “Resetting the Mass Spectrometer” on page 59 for information on how to reset the mass spectrometer. Three LEDs are located on the power panel: The Pump On LED is green when the rough pump current sensor detects current to the forepump. The LED is off when the rough-pump current sensor does not detect current to the forepump. If the current sensor detects a loss of current when the mass spectrometer is on, the vacuum system vents. The Vent Valve Closed LED is green whenever the vent valve current sensor detects current through the vent valve and the vent valve is closed. The LED is off when the vent valve is open. 24 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 2 Functional Description Mass Spectrometer The Ethernet Link OK LED is green when the System Control PCB is communicating with the data system PC. The LED is off when there is no communication between the System Control PCB and the data system PC. Figure 12. Right-side power panel of the mass spectrometer Pum p O n Electronics Vacuum Qualified Service Personnel Only ! EI CI Ion Source The ion source forms gas phase sample ions from sample molecules that elute from the GC or are introduced by the direct sample probe. You can operate the ion source in either the electron ionization (EI) or chemical ionization (CI) mode. See “Ionization Modes” on page 3. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 25 2 Functional Description Mass Spectrometer Figure 13. Ion source of the TSQ Quantum XLS Magnets and magnet yoke EI/CI Source PCB Filament Ion source block Heater ring Q00 quadrupole lens assembly L1, L2, L3, lens assembly 26 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 2 Functional Description Mass Spectrometer Figure 14. Ion source of the TSQ Quantum GC Magnets and magnet yoke EI/CI Source PCB Ion source block Filament Heater ring L1, L2, L3, and L4 lens assembly The ion volume, located in the center of the ion source, is the site where electrons interact with sample or reagent gas molecules to form ions. Three exchangeable ion volumes and ion volume holders are available for use in the ion source. See Figure 15. The choice of ion volume depends on the ionization mode. The open EI ion volume is open on the analyzer end, with a relatively large electron entrance hole. The closed EI ion volume has a smaller ion exit hole than the EI ion volume. This results in a higher pressure of analyte, and greater sensitivity, but less dynamic range. The CI ion volume is closed on the analyzer end, except for a small ion exit hole and a relatively small electron entrance hole. In the CI mode it is important to maintain a relatively high reagent gas pressure. The ion source block holds the ion volume in its center. Samples are introduced from the GC capillary column through an aperture on the side of the ion source block and then into the ion volume. Gases for calibration or chemical ionization enter the ion volume through a gas inlet tube. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 27 2 Functional Description Mass Spectrometer Figure 15. EI (left), closed EI (center), and CI (right) ion volumes and holders Ion volume holder Electron entrance hole Ion exit hole (front) GC effluent, CI gas, calibration gas entrance hole Electron exit hole Cartridge heaters heat the ion source block and lens assemblies to minimize the rate at which deposits form on the ions source block, ion volume, and lens assemblies. The ion source block is also heated to assist in the rapid temperature equilibration of the ion source block and ion volume after the filament is turned on. In EI mode, the ion source is typically maintained at 150 oC to 220 oC. However, lower or higher temperatures are sometimes used for certain applications. In the CI mode, the ion source is typically maintained at 180 oC to 200 oC. The ion source heater is feedback controlled. The filament assembly, positioned in a recess at the top of the ions source block, contains the filament, reflector, and electron lens. The filament is a rhenium wire that is electrically heated to produce electrons by thermionic emission. The reflector repels electrons emitted by the filament away from the filament toward the ion volume. The filament and its reflector are maintained at a negative potential relative to the ion volume. The electron lens prevents positive ions from traveling up the electron beam. In turn, this prevents positive ions from leaving the ion volume through the electron entrance hole. The difference in potential between the filament and the ion volume determines the electron energy. Two permanent magnets are held in a magnet yoke in the proper position above and below the ion source block. The permanent magnets collimate the electron beam and cause the beam to spiral through the ion volume. This ensures optimum ionization of the sample. Two ion source len assemblies, called the L1, L2, and L3 lens assembly and the Q00 quadrupole lens assembly, extract the ions formed in the ion source and transmit them to the ion optics. The lens L2 voltage is mass dependent. The rods of the Q00 quadrupole contact the rods of the Q0 quadrupole and share their rf and dc voltages. In positive ion mode, the lenses are adjusted to a negative potential, and in negative ion mode, the lenses are adjusted to a positive potential. The arrangement of the lenses and their spacers enables quick and efficient pump-out of the ion source. 28 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 2 Functional Description Mass Spectrometer Inlet Valve The inlet valve, which is attached to the front of the vacuum manifold, is a vacuum-sealed valve that allows you to change ion volumes or insert the direct exposure probe without venting the mass spectrometer to atmosphere. You use the insertion/removal (I/R) tool to insert or remove ion volumes. See Figure 16. The forepump evacuates the inlet valve. The ball valve is a ball with a hole in it, and it is located between the vacuum manifold and the inlet valve block. The ball valve is open when the hole in the ball is aligned with the opening between the vacuum manifold and the inlet valve. The ball valve lever opens and closes the ball valve. When the ball valve is closed, it prevents the vacuum manifold from venting to atmosphere. Figure 16. Inlet valve, I/R tool, guide bar, and ball valve lever Inlet valve I/R tool Ball valve lever Guide bar Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 29 2 Functional Description Mass Spectrometer Ion Optics The ion optics focus the ions produced in the ion source and transmit them to the mass analyzer. The ion optics includes the Q0 quadrupole and lenses L11 and L12. The Q0 quadrupole is a square array of square-profile rods that acts as an ion transmission device. See Figure 17. An rf voltage applied to the rods gives rise to an electric field that guides the ions along the axis of the quadrupole. The Q0 offset voltage increases the translational kinetic energy of ions emerging from the ion source. Figure 17. Q0 quadrupole Figure 18 gives a cross-sectional view of the transfer line, ion source, and Q0 quadrupole. 30 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 2 Functional Description Mass Spectrometer Figure 18. Cross-sectional view of the transfer line, ion source, and Q0 quadrupole of the TSQ Quantum XLS Lens L1 Q00 quadrupole Q0 quadrupole Ion source ion volume Lens L2 Lens L3 Transfer line Capillary column Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 31 2 Functional Description Mass Spectrometer Figure 19. Cross-sectional view of the transfer line, ion source, and Q0 quadrupole of the TSQ Quantum GC Lens L2 Q0 quadrupole Lens L1 Lens L3 Ion source ion volume Lens L4 Transfer line Capillary column The L11 and L12 lenses are metal disks with a circular hole in the center through which the ion beam can pass. Together they act as a two-element cone lens. An electrical potential can be applied to the lens to accelerate (or decelerate) ions as they approach the lens and to focus the ion beam as it passes through the lens. The value ranges between 0 and ±300 V. Lenses L11 and L12 also act as a vacuum baffle between the Q0 quadrupole chamber and the mass analyzer chamber. Mass Analyzer The mass analyzer separates ions according to their mass-to-charge ratio and then passes them to the ion detection system. The mass analyzer on the TSQ Quantum XLS and TSQ Quantum GC mass spectrometer consists of three quadrupole rod assemblies (Q1, Q2, and Q3) and three lens sets. The mass analyzer is discussed in detail in the following subtopics: • Quadrupole Rod Assemblies • rf and DC Fields Applied to the Quadrupoles 32 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 2 Functional Description Mass Spectrometer • Mass Analysis • Collision Cell and CID Efficiency • Quadrupole Offset Voltage • Mass Analyzer Lenses Quadrupole Rod Assemblies The three rod assemblies used in the mass spectrometer are numbered from the ion source end of the manifold and are designated Q1, Q2, and Q3. Q1 and Q3 are quadrupoles that enable high-resolution scans without signal loss. Q1 and Q3 are square arrays of precision-machined and precision-aligned, hyperbolic-profile round rods. Q1 or Q3 are shown in Figure 20. Quartz spacers act as electrical insulators between adjacent rods. Figure 20. Q1 or Q3 quadrupole Q2 is a square-profile quadrupole rod assembly. Q2 always acts as an ion transmission device. The Q2 quadrupole rods are bent through a 90-degree arc. In addition to reducing the footprint of the instrument, this prevents the transmission of unwanted neutral species to the detector and dramatically lowers the noise level in the data. Q2 has become synonymous with the term collision cell. Technically, the collision cell is the chamber that encloses Q2 where collision-induced dissociation can take place if the argon collision gas is present. See Figure 21. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 33 2 Functional Description Mass Spectrometer Figure 21. Collision cell, Q2 quadrupole, and lenses Lenses L21, L22, and L23 Lenses L31, L32, and L33 rf and DC Fields Applied to the Quadrupoles In a quadrupole rod assembly, because rods opposite each other in the array connect electrically, the four rods can be considered as two pairs of two rods each. Ac and dc voltages are applied to the rods and these voltages are ramped during the scan. Voltages of the same amplitude and sign are applied to the rods of each pair. However, the voltages applied to the different rod pairs are equal in amplitude but opposite in sign. See Figure 22. Figure 22. Polarity of the rf and dc voltages applied to the rods of the Q1 and Q3 mass analyzers RF voltage + dc voltage RF voltage 180° out of phase - dc voltage The ac voltage applied to the quadrupole rods is of constant frequency (1.123 MHz). The ac voltage applied to the rods varies from 0 to 10000 V P/P, and the dc voltage varies from 0 to ±840 V. Voltages of the same amplitude and sign are applied to each rod pair. However, the voltages applied to the other rod pair are equal in amplitude but opposite in sign. 34 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 2 Functional Description Mass Spectrometer Because the frequency of this ac voltage is in the radio frequency range, it is referred to as rf voltage. In Figure 23, the solid line represents the combined rf and dc voltage applied to one rod pair, and the dashed line represents the combined rf and dc voltage applied to the other rod pair. The ratio of rf voltage to dc voltage determines the ability of the mass spectrometer to separate ions of different mass-to-charge ratios. The first and third quadrupole rod assemblies (Q1 and Q3 quadrupoles) can act as mass analyzers or as ion transmission devices. When both rf and dc voltages are applied, Q1 and Q3 function as mass analyzers. When only rf voltage is applied, they act as ion transmission devices. In the ion transmission mode, the quadrupole rod assemblies allow ions in a wide window of mass-to-charge ratios to pass. The square quadrupole rod assembly (Q2) operates in the ion transmission mode only. Surrounding Q2 is a collision cell where collision-induced dissociation (CID) can take place if the argon collision gas is present in the cell. Figure 23. Magnitude of the rf and dc voltages applied to the rods of the Q1 and Q3 mass analyzers 10,000 V P/P 840 V DC VOLTAGE Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 35 2 Functional Description Mass Spectrometer Mass Analysis The Q1 and Q3 rods are charged with a variable ratio of rf voltage and dc voltage (Figure 23). These potentials give rise to an electrostatic field that gives stable oscillations to ions with a specific mass-to-charge ratio and unstable oscillations to all others. At any given instant, one particular set of rf and dc voltage values is being applied to the mass analyzer rods. Under these conditions, only ions of one mass-to-charge ratio (for example, m/z 180) are maintained within bounded oscillations as their velocity carries them through the mass analyzer. During this same time, all other ions undergo unbounded oscillations. These ions strike one of the rod surfaces, become neutralized, and are pumped away, or they are ejected from the rod assembly. Then, at a later time, both rf and dc voltages change, and ions of the next mass-to-charge ratio (for example, m/z 181) are allowed to pass, while all other ions (including m/z 180) become unstable and undergo unbounded oscillations. This process continues, with ions of one mass-to-charge ratio after another being transmitted, as the rf and dc voltages change in value. At the end of the scan, the rf and dc voltages are discharged to zero, and the process is repeated. The potentials on the quadrupole rods can be changed rapidly and precisely. The rf and dc voltages in the mass spectrometer can be scanned over the full mass range of the system, m/z 10 to 3000, in 0.6 s. The precision quadrupole rods of the mass spectrometer provide excellent sensitivity, peak shape, resolution, and high mass transmission. Collision Cell and CID Efficiency In the MS/MS scan modes, the mass spectrometer applies a large voltage of opposite polarity to the Q2 rod pairs between scans, which empties the collision cell. This process ensures that no ions remain in the collision cell from scan to scan. The collision cell quadrupole rod assembly (Q2), which always acts as an ion transmission device, is a quadrupole array of square-profile rods. A variable rf voltage charges the rods, which creates an electrostatic field that gives stable oscillations to ions in a wide window of mass-to-charge ratios. The collision cell surrounds Q2 and is usually pressurized from about 1 × 10-3 to 4 × 10-3 Torr with argon collision gas. The collision cell is where collision-induced dissociation (CID) takes place. CID is a process in which an ion collides with a neutral atom or molecule and then, because of the collision, dissociates into smaller fragments. The mechanism of dissociation involves converting some of the translational kinetic energy (TKE) of the ion into internal energy. This collision places the ion in an excited state. If the internal energy is sufficient, the ion fragments. 36 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 2 Functional Description Mass Spectrometer Three expression convey the efficiency of the CID process: • Collection efficiency • Fragmentation efficiency • Overall CID efficiency Collection efficiency The ion flux ratio measured at the exit of the collision cell and at its entrance. With no collision gas present, the mass spectrometer obtains virtually 100 percent collection efficiency. Collection efficiency is a mass-dependent parameter. For example, with mid-range collision gas pressure, the collection efficiency might vary from about 50 percent for comparatively less massive ions (which are more prone to scatter) up to 75 percent for comparatively more massive ions (which are less prone to scatter). Fragmentation efficiency The fraction of the ion flux at the exit of the collision cell that results from fragmented ions. Fragmentation efficiency depends directly on the stability of the ion and indirectly on the mass of the ion. The more stable the ion, the less likely a given collision will fragment the ion. Typically, low mass ions require a higher collision energy to dissociate than high mass ions. To compensate for this, the data system allows you to specify a mass-dependent collision energy ramp. With a mid-range collision gas pressure, fragmentation efficiency might vary from 15 percent to 65 percent for various compounds. As the collision gas pressure increases, the fragmentation efficiency for all compounds approaches 100 percent due to multiple collisions. The collection efficiency decreases, however, due to scattering. Overall CID efficiency The product of the collection efficiency and the fragmentation efficiency. The overall CID efficiency exhibits a maximum with intermediate pressure. As the pressure is increased beyond the optimum value, more and more collisions take place, the probability of scattering increases, and fewer and fewer ions pass through the collision cell. This results in the collection efficiency decreasing. The fragmentation efficiency also decreases as the pressure is decreased from its optimum value, because fewer and fewer collisions take place. Quadrupole Offset Voltage The quadrupole offset voltage is a dc potential applied to the quadrupole rods in addition to the ramping dc voltage. The offset voltage applied to the two rod pairs of the assemblies is equal in magnitude and equal in sign. The quadrupole offset voltage accelerates or decelerates ions and, therefore, sets theTKE of the ions as they enter the quadrupole rod assembly. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 37 2 Functional Description Mass Spectrometer In general, for a given experiment, the mass spectrometer has fixed offset voltages for Q1 and Q2. However, in MS/MS experiments, the quadrupole offset voltage applied to Q3 usually varies as a scan proceeds. The mass spectrometer automatically computes the Q3 quadrupole offset voltage necessary and then varies the voltage, as appropriate, as each scan proceeds. The offset voltage applied to Q2 (which contains the collision cell) is responsible for the collision energy. The collision energy is the difference in potential between the ion source (where parent ions are formed) and Q2 (where they collide with collision gas). As the offset voltage on Q2 increases, the TKE of the parent ions also increases. As a result, increases in the Q2 offset voltage increase the energy of ion/Ar collisions. The collision energy is usually ramped downward with m/z to promote the fragmentation of low mass ions. Before obtaining any mass spectra, the mass spectrometer tunes Q1 in the Q1MS scan mode (Q2 and Q3 rf voltage only), and tunes Q3 in the Q3MS scan mode (Q1 and Q2 rf voltage only). During tuning, the mass spectrometer determines the optimum quadrupole offset voltage for Q1 and for Q3. Mass Analyzer Lenses The TSQ Quantum XLS and TSQ Quantum GC mass analyzers have three lens sets. See Figure 21 on page 34. Those between Q1 and Q2 are designated L21, L22, L23; those between Q2 and Q3 are designated L31, L32, L33; and the lens between Q3 and the ion detection system is designated as L4 (or exit lens). All of the lenses have circular holes in their centers through which the ion beam passes. The lens assemblies also retain the three rod assemblies to ensure accurate and automatic axial alignment of the rod assemblies. The L2x lens set (between Q1 and Q2) and the L3x lens set (between Q2 and Q3) serve these functions: • To minimize the amount of collision gas that enters the mass analyzers (Q1 and Q3) from the collision cell (Q2). Lenses L22 and L21 on one side of Q2 and lenses L32 and L33 on the other side of Q2 act as baffles. (For high-mass transmission, it is important to maintain a low pressure in the mass analyzers.) • To retain the collision gas. Lenses L23 and L3 form two of the walls of the collision cell, so they tend to hold the collision gas in the collision cell. The collision gas escapes, however, through the same lens holes through which the ion beam passes. • To shield Q1 from the rf voltage applied to Q2 and vice versa (L2x lens set) and to shield Q3 from the rf voltage applied to Q2 and vice versa (L3x lens set). • To focus the ion beam. The three lenses between Q1 and Q2 (and those between Q2 and Q3) together form a three-element aperture lens. The first and third lenses are generally set to similar or identical values and the central lens is set to a value different (either higher or lower) from the other two. 38 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 2 Functional Description Mass Spectrometer The voltage applied to each of the lenses can vary from about -300 to +300 V. Typically, however, the voltage applied to the first and third elements of the L2x lens set is somewhat greater than the quadrupole offset voltage applied to Q1. Because the Q1 quadrupole offset voltage is generally set to about ±5 V (depending on the charge of the ions of interest), the voltage applied to lenses L21 and L23 is typically about -10 V for positive ions and +10 V for negative ions. The voltage applied to the central lens of the L2x lens set is typically about ±225 V. In the Q3MS scan mode, the voltage applied to the lenses of the L3x lens set is about the same as that applied to the corresponding lens in the L2x lens set. Note, however, that in the MS/MS scan modes, the voltage applied to the L3x lens set automatically varies with the quadrupole offset voltage applied to Q3. As the Q3 quadrupole offset voltage ramps, the voltages applied to the lenses ramp correspondingly. Lens L4 is located between Q3 and the ion detection system. L4 is held at ground potential. Its purpose is to shield Q3 from the high voltage applied to the ion detection system and to shield the ion detection system from the high rf voltages applied to Q3. Ion Detection System The TSQ Quantum XLS and TSQ Quantum GC mass spectrometers are equipped with a high-sensitivity, off-axis ion detection system. See Figure 24. This system produces a high signal-to-noise ratio and allows for voltage polarity switching between positive ion and negative ion modes of operation. The ion detection system includes a 15 kV conversion dynode and a channel electron multiplier. The ion detection system is located at the rear of the vacuum manifold behind the mass analyzer. The conversion dynode is a concave metal surface located at a right angle to the ion beam. The mass spectrometer applies to the conversion dynode a potential of +15 kV for negative ion detection or -15 kV for positive ion detection. When an ion strikes the surface of the conversion dynode, one or more secondary particles are produced. These secondary particles can include positive ions, negative ions, electrons, and neutrals. When positive ions strike a negatively charged conversion dynode, the secondary particles of interest are negative ions and electrons. When negative ions strike a positively charged conversion dynode, the secondary particles of interest are positive ions. The curved surface of the conversion dynode focuses these secondary particles and a voltage gradient accelerates the particles into the electron multiplier. The electron multiplier includes a cathode and an anode. The cathode of the electron multiplier is a lead-oxide, funnel-like resistor. The high voltage ring applies a potential of up to -2.5 kV to the cathode. The exit end of the cathode (at the anode) is near ground potential. The anode of the electron multiplier is a small cup located at the exit end of the cathode. The anode collects the electrons produced by the cathode. The anode screws into the anode feedthrough in the base plate. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 39 2 Functional Description Mass Spectrometer Figure 24. Ion detection system, showing the electron multiplier (top) and conversion dynode (bottom) Secondary particles from the conversion dynode strike the inner walls of the electron multiplier cathode with sufficient energy to eject electrons. The ejected electrons are accelerated farther into the cathode, drawn by the increasingly positive potential gradient. The funnel shape of the cathode causes the ejected electrons not to travel far before they again strike the inner surface of the cathode, which causes the emission of more electrons. A cascade of electrons is then created that finally results in a measurable current at the end of the cathode where the anode collects the electrons. The current collected by the anode is proportional to the number of secondary particles striking the cathode. Typically, the electron multiplier is set to a gain of about 3 × 105 (that is, for each ion or electron that enters, 3 × 105 electrons exit) in MS mode and 2 × 106 in MS/MS mode. The electrometer circuit converts the current that leaves the electron multiplier via the anode to a voltage and the data system records the voltage. The ion detection system of the mass spectrometer increases signal and decreases noise. The high voltage applied to the conversion dynode results in a high conversion efficiency and increased signal. That is, for each ion striking the conversion dynode, many secondary particles are produced. The increase in conversion efficiency is more pronounced for more massive ions than it is for less massive ions. Because of the off-axis orientation of the ion detection system relative to the mass analyzer, neutral molecules from the mass analyzer tend not to strike the conversion dynode or electron multiplier. As a result, noise from neutral molecules is reduced. 40 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 2 Functional Description Mass Spectrometer Vacuum System and Inlet Gasses Hardware The vacuum system evacuates the region around the ion source, ion optics, mass analyzer, and ion detection system. The principal components of the vacuum system include the following: • Vacuum Manifold • Turbomolecular Pump • Forepump • Convectron Gauges • Ion Gauges The inlet gasses hardware controls the flow of collision gas, CI reagent gas, calibration compound, and air (during venting) into the mass spectrometer. The inlet gasses hardware includes the following components: • Vent Valve • Collision Gas Flow Control Valves • Calibration Compound and CI Reagent Gas Flow Control Figure shows a functional block diagram of the vacuum system and inlet gasses hardware. Figure 25. Functional block diagram of the vacuum system and inlet gasses hardware Calibration compound vial Calibration compound valve CI reagent gas valve CI reagent gas port Air filter Ion gauge Gas chromatograph Transfer line Inlet valve Vent valve Ion source Q0 quadrupole chamber chamber (4 x 10 - 5 Torr) Analyzer chamber (3 x 10 - 6 Torr) Dual-inlet turbomolecular pump Convectron gauge Exhaust Collision cell Ion gauge Convectron gauge Collision gas divert valve Forepump Collision gas valve Thermo Scientific Argon gas port TSQ Quantum XLS and TSQ Quantum GC User Guide 41 2 Functional Description Mass Spectrometer Vacuum Manifold The vacuum manifold encloses the ion source, ion optics, mass analyzer, and ion detection system assemblies. The vacuum manifold is a thick-walled, aluminum chamber with two removable side cover plates, with openings on the front, sides, and top, and various electrical feedthroughs and gas inlets. The main vacuum manifold is divided into two chambers by a baffle. See Figure 26. The high vacuum port of the turbomolecular pump evacuates the region inside the first chamber, called the analyzer region, to less than 10-5 Torr. The turbomolecular pump then discharges into the forepump through the foreline. The region inside the second chamber, called the Q0 quadrupole region, is evacuated to 1 mTorr by the interstage port of the turbomolecular vacuum pump. A second vacuum manifold houses the ion source, which is open to the Q0 quadrupole chamber. The interstage port of the turbomolecular pump evacuates the ion source region. 42 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 2 Functional Description Mass Spectrometer Figure 26. Vacuum manifold (interior) O-ring Ion gauge Turbomolecular pump Baffle Collision cell chamber Analyzer chamber Ion gauge Q0 quadrupole chamber Ion source chamber When CID is turned on, the collision cell chamber, inside the analyzer chamber, has a user controlled argon pressure of between 1 and 4 mTorr. The forepump evacuates the argon in the collision cell when CID is turned off. Two removable side cover plates on the left side of the vacuum manifold allow access to the Q0 ion optics, mass analyzer, and ion detection system. Two electrically conductive O-rings provide a vacuum-tight seal between the side cover plates and the vacuum manifold. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 43 2 Functional Description Mass Spectrometer Turbomolecular Pump A Leybold TW220/150/15S double-inlet turbomolecular pump provides the vacuum for the ion source, Q0 quadrupole region, and analyzer region of the vacuum manifold. The turbomolecular pump mounts onto the top of the vacuum manifold (Figure 26). The turbomolecular pump has two pumping inlets: • A high-vacuum inlet at the top of the rotor stack, which evacuates the analyzer chamber • An interstage inlet about halfway down the rotor stack, which evacuates the ion source and Q0 quadrupole chambers The turbomolecular pump is controlled by a Leybold TDS controller and powered by a +24 V dc (250 W) power supply. The mass spectrometer circuit breaker switch and the vacuum service switch, but not the electronics service switch, turn power for the turbomolecular pump off and on. A fan draws air in from the front of the instrument cools the pump. Power to the turbomolecular pump shuts off if the foreline pressure, as measured by the Convectron gauge, is too high, or if the turbomolecular temperature is too high. Forepump An Edwards E2M30 forepump (or roughing pump) establishes the vacuum necessary for the proper operation of the turbomolecular pump. The forepump also evacuates the inlet valve and the collision cell. The pump has a maximum displacement of 650 L/min and maintains a minimum pressure of approximately 1 Pa (0.01 Torr). The forepump is connected to the turbomolecular pump by a section of reinforced PVC tubing. The power cord of the forepump is plugged into the outlet labeled Forepump on the power panel (see Figure 12 on page 25). This outlet supplies power to the pump and is controlled by the main power circuit breaker switch and vacuum service switch, not by the electronics service switch. CAUTION Always plug the forepump power cord into the outlets labeled Forepump on the right side power panel of the mass spectrometer. Never plug it directly into a wall outlet. 44 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 2 Functional Description Mass Spectrometer Convectron Gauges A Convectron™ gauge measures the pressure in the inlet valve and the foreline, which connects the turbomolecular pump and the forepump. A second Convectron gauge measures the pressure of argon collision gas in the collision cell. The Convectron gauge uses a Wheatstone bridge with a temperature dependent resistor to measure pressure down to a fraction of a milliTorr. The voltage present at the top of the bridge depends on how fast the resistor can radiate heat, which is related to the pressure. The pressure measured by the Convectron gauge is monitored by vacuum protection circuitry on the Source PCB, which in turn is monitored by the embedded computer on the System Control PCB. The vacuum protection circuitry detects whether the foreline pressure is too high for the proper operation of the turbomolecular pump. Ion Gauges A Granville-Phillips® 342™ mini ion gauge measures the pressures in the analyzer region of the vacuum manifold and the Q0/ion source region. The ion gauge produces energetic electrons that cause the ionization of molecules in the ion gauge. Positive ions formed in the ion gauge are attracted to a collector. The collector current is related to the pressure in the vacuum manifold. The ion gauge is also involved in vacuum protection. Vent Valve The vent valve, located in the area of Q2, allows the vacuum manifold to be vented to air that has been filtered through a sintered nylon filter. The vent valve is a solenoid-operated valve, which is controlled by the Vent Delay PCB. When the solenoid is energized, the vent valve closes. If the power fails or the main power circuit breaker is placed in the Off (O) position, a 4-farad capacitor located in the Power Entry Module keeps the solenoid in the closed position for several minutes. If power is not restored in this time, then the solenoid opens and the system is vented with filtered air. The vent valve closes after power is restored to the mass spectrometer. Collision Gas Flow Control Valves The collision gas flow control valves control the flow of argon collision gas into and out of the Q2 collision cell. A solenoid valve acts to shut off argon gas flow to the cell. The collision gas pressure is regulated by a proportional valve that is controlled by the data system. You can set the collision gas pressure (0 to 5 milliTorr) in the Define Scan dialog box of the EZ Tune window. Ions enter the Q2 collision cell, collide with the argon collision gas, and then, because of the collision, dissociate into smaller fragments. See “Collision Cell and CID Efficiency” on page 36. Argon enters the mass spectrometer through a 1/8 in. port on the left side of the mass spectrometer. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 45 2 Functional Description Mass Spectrometer A second proportional valve allows the forepump to evacuate the Q2 collision cell of argon and waste gasses when CID is turned off. The mass spectrometer automatically opens and closes the collision gas evacuation valve, depending on whether Q2 is acting as an ion transmission device or a collision cell. Calibration Compound and CI Reagent Gas Flow Control The calibration compound gas flow control valve controls the flow of calibration compound gas into the ion source, via the transfer line. The calibration gas flow can be either high or low. Normally low flow is used, but high flow might be necessary for negative ion CI calibration. The CI gas flow control valve controls the flow of chemical ionization reagent gas into the ion source, via the transfer line. The maximum CI gas flow rate is about 4 mL/min, depending on the gas. Electronic Assemblies The electronic assemblies that control the operation of the mass spectrometer are distributed among various PCBs and other modules located in the tower, in the embedded computer, and on or around the vacuum manifold of the mass spectrometer. The Power Entry Module provides mass spectrometer power control, a contact closure interface, vent valve control, an Ethernet 100 base-T connection from the System Control PCB to the data system PC, a mechanical pump failure protection circuit (linked to vent valve control), a system reset button, status LEDs, and service ports. The right-side power panel, shown in Figure 12 on page 25, is part of the Power Entry Module. The Power Entry Module accepts line power, filters it, and provides it to various components of the mass spectrometer. The Power Module includes the following components: • Main power circuit breaker switch • Surge suppressor • Line filter • Electronics service switch • Vacuum service switch The “brains” of the TSQ Quantum XLS and TSQ Quantum GC mass spectrometers are the System Control PCB. The System Control PCB and embedded computer include the following: • PowerPC processor • Serial Peripheral Interconnect (SPI) bus • I/O coprocessor • Super Harvard Architecture Computer (Sharc) bus 46 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 2 Functional Description Mass Spectrometer • Scan generator DSP • Acquisition processor DSP • Interbus bridge • 100 base-T Ethernet port The rf voltage generation electronic assemblies produce the Q0, Q1, Q2, and Q3 rf voltages that enable ion transmission and mass analysis. All rf voltages are controlled by the Analyzer Control PCB and the System Control PCB. The Q1 and Q3 rf voltage amplifier circuits are identical, and the circuits for Q0 and Q2 are similar. The rf voltage generation electronic assemblies include the following components: • rf oscillator • rf Voltage Amplifier PCB • Low Pass Filter PCB • rf voltage coil • rf voltage detector • Mass DAC • Integrating amplifier The ion detection system electronic assemblies provide high voltage to the electron multiplier and conversion dynode of the ion detection system. They also receive the electron multiplier output current signal, convert it to a voltage (by the electrometer circuit), and pass it to the embedded computer. The ion detection system electronic assemblies include the following: • Electron multiplier power supply • Conversion dynode power supply • Electrometer PCB • Acquisition DSP The Analyzer Control PCB contains circuitry for controlling and monitoring the operation of the ion source, ion optics, mass analyzer, and ion detection system. These circuits are in turn monitored by the PowerPC processor of the System Control PCB via the SPI bus. The Analyzer Control PCB controls and monitors the rf voltages for Q0, Q1, Q2, and Q3 quadrupoles. It also has lens voltage drivers that convert ±330 V dc power from the DC Rod Driver PCB to dc voltages that are applied to the lenses Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 47 2 Functional Description Data System Data System The data system controls and monitors the TSQ Quantum XLS and TSQ Quantum GC mass spectrometers. The data system also processes data that the mass spectrometer acquires. The data system is composed of the following: • Computer Hardware • Data System / Mass Spectrometer / GC Interface • Data System / Local Area Network Interface Computer Hardware The data system computer has the following major features: • Intel® Pentium® IV processor • High capacity hard disk drive • Recordable/rewriteable CD drive • Primary Ethernet port (data system to mass spectrometer) • Secondary Ethernet port (data system to local area network) • High performance video graphics card • CDRW drive • DVD drive • 1280×1024 resolution color monitor • Keyboard and mouse For more information about the computer, refer to the appropriate manuals. Data System / Mass Spectrometer / GC Interface The data system computer contains a 100 base-T Ethernet adapter (called the primary Ethernet adapter) that is dedicated to data system/mass spectrometer/GC communications. This primary Ethernet adapter communicates with the mass spectrometer and GC modules via a 10/100 base-T Ethernet switch. The Ethernet adapter on the mass spectrometer resides on the System Control PCB. A twisted pair, Ethernet cable connects the primary Ethernet adapter of the data system to the Ethernet switch, which is connected to the Ethernet connector on the power panel of the mass spectrometer and to the GC. 48 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 2 Functional Description Data System Data System / Local Area Network Interface The data system computer contains a secondary Ethernet adapter. This secondary Ethernet adapter is not involved in data system/mass spectrometer or GC communications. You can use this secondary Ethernet adapter to access your local area network. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 49 3 System Shutdown, Startup, and Reset Many maintenance procedures for the TSQ Quantum XLS and TSQ Quantum GC systems require that the mass spectrometer be shut down completely. In addition, you can place the mass spectrometer in Standby mode if the system is not to be used for 12 hours or more. Contents • Shutting Down the System in an Emergency • Placing the System in Standby Mode • Shutting Down the System Completely • Starting Up the System after a Complete Shutdown • Resetting the Mass Spectrometer • Resetting the Data System • Turning Off Selected Mass Spectrometer Components Shutting Down the System in an Emergency You can turn off all power to the mass spectrometer, gas chromatograph, and autosampler by pressing the System Power Off button, located on the front of the electronics module, or the main power circuit breaker, located on the rear of the electronics module. You can turn on the system power only with the main power circuit breaker on the rear of the electronics module and not the System Power Off switch. Y To turn off the mass spectrometer in an emergency CAUTION Press the System Power Off button located on the front of the electronics module. See Figure 27. The System Power Off button turns off all power to the mass spectrometer (including the vacuum pumps), gas chromatograph, and autosampler. Although removing power abruptly does no harm to any component within the system, under normal conditions do not shut down the system with the System Power Off button. For the recommended procedure, see “Shutting Down the System Completely” on page 53. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 51 3 System Shutdown, Startup, and Reset Placing the System in Standby Mode Figure 27. System Power Off button on the front of the electronics module System Power Off button Figure 28. Power panel on the rear of the electronics module Power In GC Power Out Quantum Power Out A/S Power Out ! ! V~230 Hz, 30A MAX V~230 50/60 Hz, 16A MAX V~230 50/60 Hz, 10A MAX V~230 50/60 Hz, 2A MAX Placing the System in Standby Mode If you are not going to use the TSQ Quantum XLS or TSQ Quantum GC system for a short period of time, such as overnight or over weekends, it does not need to be shut down completely. When you are not going to operate the system for 12 hours or more, you can leave the system in standby mode. Y To place the TSQ Quantum XLS or TSQ Quantum GC system in standby mode 1. Wait until data acquisition, if any, is complete. On 52 Off Standby 2. From the TSQ EZ Tune window, choose Control > Standby (or click the On/Standby button) to put the mass spectrometer in standby. TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 3 System Shutdown, Startup, and Reset Shutting Down the System Completely When you choose Control > Standby, the TSQ Quantum XLS or TSQ Quantum GC system turns off the electron multiplier, the conversion dynode, the ion source filament and lenses (but not the heater), and the mass analyzer and ion optics rf voltages. See Table 4 on page 60 for the On/Off status of mass spectrometer components when the mass spectrometer is in standby mode. The System LED on the front panel of the mass spectrometer illuminates yellow when the system is in standby. 3. Leave the mass spectrometer power on. 4. Leave the GC power on with column flow. 5. Leave the autosampler power on. 6. Leave the data system power on. Shutting Down the System Completely Shut down the TSQ Quantum XLS or TSQ Quantum GC system completely only if it is to be unused for an extended period or if it must be shut down for a maintenance or service procedure. For a short period of time, such as overnight or over weekends, you can place the system in standby mode. See “Placing the System in Standby Mode.” Y To shut down the TSQ Quantum XLS or TSQ Quantum GC system completely 1. Cool the GC, transfer line, and ion source: • GC oven 30 oC • Injector off • Transfer line off • Ion source 30 oC Note If you do not plan to change the column or perform maintenance on the gas chromatograph, you do not have to lower the injector temperature. 2. From the TSQ EZ Tune window, choose Control > Standby (or click the On/Standby button) to put the mass spectrometer in standby. 3. Place the electronics service switch, located on the right-side power panel, in the Service Mode. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 53 3 System Shutdown, Startup, and Reset Shutting Down the System Completely Figure 29. Right-side power panel of the mass spectrometer Pum p O n Electronics Vacuum Qualified Service Personnel Only ! 4. Place the vacuum service switch, located on the right-side power panel, in the Service Mode position. 5. Place the mass spectrometer main power circuit breaker switch, located on the right-side power panel, in the Off position. When you place the main power circuit breaker switch in the Off position, the following occurs: • All power to the mass spectrometer is turned off. (All LEDs on the front panel of the mass spectrometer are off.) • A capacitor on the Vent Delay PCB provides power to the vent valve for two to four minutes (to allow the turbomolecular pump to spin down). After the capacitor discharges, power to the vent valve solenoid shuts off. When power to the vent valve solenoid shuts off, the vent valve opens and the vacuum manifold vents to filtered air. You can hear a hissing sound as the air passes through the air filter. • After about two minutes, the pressure of the vacuum manifold reaches atmospheric pressure. 6. Unplug the power cord for the mass spectrometer. CAUTION Allow heated components to cool before servicing them. 54 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 3 System Shutdown, Startup, and Reset Starting Up the System after a Complete Shutdown Note If you plan to perform routine or preventive system maintenance on the mass spectrometer only, you can leave the argon, data system, GC, and autosampler on. In this case, the shutdown procedure is complete. However, if you do not plan to operate your system for an extended period of time, Thermo Fisher Scientific recommends that you turn off the GC, data system, and autosampler as described in steps 7 through 12 below. 7. Turn off the GC. Follow the procedure described in the manual that came with the GC. 8. Turn off the autosampler by using the main power on/off switch. 9. Press the System Power Off button (Figure 27) to remove all power from the TSQ Quantum XLS or TSQ Quantum GC system. 10. If the system is not to be used for an extended period, turn off the argon collision gas supply at the tank. 11. Turn off the data system: a. Choose Start > Shut Down from the Windows® task bar. The Shut Down Windows dialog box appears. b. To start the Windows shutdown procedure, select Shut down and click OK. 12. Turn off the (optional) printer by using the on/off switch. CAUTION Burn Hazard. The ion source, GC oven, injector, and transfer line are hot. Allow them to cool to room temperature before touching them. Starting Up the System after a Complete Shutdown Starting the TSQ Quantum XLS or TSQ Quantum GC system after it has been shut down completely requires the following: • Restoring Power to the TSQ Quantum XLS or TSQ Quantum GC system • Starting Up the GC • Starting Up the Data System • Starting Up the Mass Spectrometer • Starting Up the Autosampler (autosampler is optional) • Setting Up Conditions for Operation Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 55 3 System Shutdown, Startup, and Reset Starting Up the System after a Complete Shutdown Restoring Power to the TSQ Quantum XLS or TSQ Quantum GC system Y To restore power to the TSQ Quantum XLS or TSQ Quantum GC system Place the main power circuit breaker, located on the rear of the electronics module (Figure 28), in the On position. Starting Up the GC Y To start the GC Follow the startup procedure described in the manual that came with the GC. Verify that the gas chromatograph is on and there is carrier gas flowing through the column into the mass spectrometer. Starting Up the Data System Y To start the data system 1. Turn on the monitor, computer, and printer. 2. Observe the Windows startup procedure on the monitor and press CONTROL+ALT+DELETE when you are prompted to do so. To complete the startup procedure, click OK or enter your password (if you have one) in the Logon Information dialog box. Starting Up the Mass Spectrometer Y To start the mass spectrometer CAUTION If you turn on the mass spectrometer without column flow, air can damage the GC column. This large air leak into the TSQ Quantum GC also causes the ion source to require cleaning. 1. Turn on the flow of argon at the tank if it is off. IMPORTANT The data system must be running before you start the mass spectrometer. The mass spectrometer will not operate until it receives software from the data system. 2. Make sure that the mass spectrometer main power circuit breaker switch, located on the right side power panel (Figure 29), is in the Off (O) position and the electronics service switch and the vacuum service switch are both in the Service Mode position. 56 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 3 System Shutdown, Startup, and Reset Starting Up the System after a Complete Shutdown 3. Plug in the power cord for the mass spectrometer. 4. Place the mass spectrometer main power circuit breaker switch in the On (|) position. When you place the main power circuit breaker switch in the On (|) position, power is supplied to those mass spectrometer components that are not affected by the vacuum service switch and the electronics service switch. 5. Place the vacuum service switch in the Operational position. 6. Place the electronics service switch in the Operational position. When you place the electronics service switch in the Operational position, the following occurs: • The Power LED on the mass spectrometer front panel illuminates green to indicate that power is provided to the mass spectrometer electronics. (The electron multiplier, conversion dynode, ion source, and mass analyzer and ion optics rf voltages remain off.) • The embedded computer reboots. After several seconds the Communication LED on the front panel illuminates yellow to indicate that the data system and the mass spectrometer have started to establish a communication link. • After several more seconds, the Communication LED illuminates green to indicate that the data system and the mass spectrometer have established a communication link. Software for the operation of the mass spectrometer is then transferred from the data system to the mass spectrometer. • After three minutes, the System LED illuminates yellow to indicate that the software transfer from the data system to the mass spectrometer is complete and that the instrument is in standby. • The Vacuum LED on the front panel of the mass spectrometer remains off until the turbomolecular pump reaches 80 percent of its operational speed of 750 Hz. At this time the ion gauge is turned on and the Vacuum LED illuminates yellow. The Vacuum LED illuminates green, and the high voltage can be turned on, only if the pressure in the mass analyzer region of the vacuum manifold is less than the appropriate value listed in Table 3. Table 3.Maximum allowed pressure to turn on high voltage Thermo Scientific Carrier gas Ar collision gas Maximum pressure (Torr) He Off 6 × 10-6 He On 5 × 10-5 H2 Off 5 × 10-5 H2 On 1 × 10-4 TSQ Quantum XLS and TSQ Quantum GC User Guide 57 3 System Shutdown, Startup, and Reset Starting Up the System after a Complete Shutdown Figure 30. Front panel LEDs of the mass spectrometer Power Vacuum System Communication Scan If you have an autosampler, go to Starting Up the Autosampler. If you do not have an autosampler, go to Setting Up Conditions for Operation. Starting Up the Autosampler Y To start the autosampler Place the main power switch on the autosampler in the On position. If necessary, configure the autosampler. For procedures for placing sample vials, preparing solvent and waste bottles, installing syringes, and so on, refer to the manual that came with the autosampler. Setting Up Conditions for Operation Y To set up your TSQ Quantum XLS or TSQ Quantum GC mass spectrometer for operation 1. Before you begin data acquisition with your TSQ Quantum XLS system, allow the system to pump down for at least one hour. Operation of the system with excessive air and water in the vacuum manifold can cause reduced sensitivity, tuning problems, and reduced lifetime of the electron multiplier. 2. Ensure that the argon pressure is within the operational limits [argon: 135 ±70 kPa (20 ±10 psig)]. Note Air in the argon line must be purged or given sufficient time to be purged for normal TSQ Quantum XLS mass spectrometer performance. 3. In the TSQ EZ Tune window, choose View > Instrument Status. Look at the Status view. Check that the pressure measured by the ion gauge is below about 3 × 10-6 Torr (2 × 10-5 Torr with H2 carrier gas) with the collision gas turned off. Note You do not need to calibrate and tune the mass spectrometer each time you restart the TSQ Quantum XLS or TSQ Quantum GC system. To tune and calibrate the mass spectrometer, see Chapter 4, “Tuning and Calibrating.” 58 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 3 System Shutdown, Startup, and Reset Resetting the Mass Spectrometer Resetting the Mass Spectrometer If communication between the mass spectrometer and data system computer is lost, it might be necessary to reset the mass spectrometer using the System Reset button on the right-side power panel. Pressing the System Reset button creates an interrupt in the embedded computer. This causes the embedded computer to restart in a known (default) state. See Figure 29 on page 54 for the location of the System Reset button. The procedure given here assumes that the mass spectrometer and data system computer are both powered on and operational. If the mass spectrometer, data system computer, or both are off, go to “Starting Up the System after a Complete Shutdown” on page 55. Y To reset the mass spectrometer Press the System Reset button located on the right-side power panel. Make sure the Communication LED is extinguished before releasing the System Reset button. When you press the Reset button, the following occurs: • An interrupt on the embedded computer causes the CPU to reboot. All LEDs on the front panel of the mass spectrometer are off except the Power LED. • After several seconds, the Communication LED illuminates yellow to indicate that the data system and the mass spectrometer are starting to establish a communication link. • After several more seconds, the Communication LED illuminates green to indicate that the data system and the mass spectrometer have established a communication link. Software for the operation of the mass spectrometer is then transferred from the data system to the mass spectrometer. • After three minutes the software transfer is complete. The System LED illuminates either green to indicate that the instrument is functional and the high voltages are on, or yellow to indicate that the instrument is functional, and it is in standby. Resetting the Data System If possible, use the Windows shutdown and restart procedure to shut down and restart the data system so that Windows can properly close programs and save changes to files. Y To reset the data system by using the Windows shutdown and restart procedure 1. Choose Start > Shut Down from the Windows task bar. The Shut Down Windows dialog box appears. 2. Select Restart and click OK to start the Windows shutdown and restart procedure. 3. Observe the Windows shutdown and restart procedure on the monitor. Press CTRL+ALT+DELETE when you are prompted to do so. To complete the shutdown and Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 59 3 System Shutdown, Startup, and Reset Turning Off Selected Mass Spectrometer Components restart procedure, click OK or enter your password (if you have one) in the Logon Information dialog box. Note The communications link between the data system and the mass spectrometer should automatically reestablish after you reset the data system. When this occurs the Communication LED on the front panel of the mass spectrometer illuminates yellow and then green. If the system is unable to reestablish the communications link, press the System Reset button on the power panel of the mass spectrometer. Turning Off Selected Mass Spectrometer Components There are different ways that you can turn off some or all of the mass spectrometer components: • Turn off individual mass spectrometer components from the TSQ EZ Tune window. Turning off individual mass spectrometer components might be necessary when you are troubleshooting or when you are running certain diagnostic procedures. • Place the mass spectrometer in Standby mode. Standby is the normal condition to leave the mass spectrometer in when it is not in use. Choose Control > Standby (or toggle the On/Standby button) from the TSQ EZ Tune window to place the mass spectrometer in standby. • Place the mass spectrometer in the Off condition. The Off condition is similar to Standby, except all high voltage components of the mass spectrometer are turned off. Choose Control > Off from the TSQ EZ Tune window to place the mass spectrometer in the Off condition. • Place the electronics service switch in the Service Mode position. The electronics service switch turns off all components in the mass spectrometer other than the +24 V power supply, forepump, turbomolecular pump, Vent Delay PCB, and fans. • Place the vacuum service switch in the Service Mode position. The vacuum service switch turns off all vacuum system components, including the +24 V power supply, forepump, turbomolecular pump, Vent Delay PCB, and fans. • Place the right-side power panel circuit breaker switch in the Off position. Placing the right-side power panel circuit breaker switch in the Off position removes all power to the mass spectrometer, including the vacuum system. • Press the System Power Off button. Pressing the System Power Off button removes all power to the mass spectrometer, gas chromatograph, and autosampler. Table 4 summarizes the on/off status of mass spectrometer components, voltages, and gas flows. 60 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 3 System Shutdown, Startup, and Reset Turning Off Selected Mass Spectrometer Components Table 4. On/Off status of mass spectrometer components and voltages (Sheet 1 of 2) Standby Off Mass spectrometer component Electronics service switch in Service Mode position Vacuum service switch in Service Mode position MS Main power circuit breaker switch in Off position Electron multiplier Off Off Off Off Off Conversion dynode Off Off Off Off Off Mass analyzer rf voltage Off Off Off Off Off Mass analyzer dc offset voltage Off Off Off Off Off Q0 ion optics rf voltage Off Off Off Off Off Q0 ion optics dc offset voltage Off Off Off Off Off Ion source filament Off Off Off Off Off Ion source heater On On Off Off Off Ion source lenses Off Off Off Off Off Argon collision gas Off Off Off Off Off Vent valve Closed Closed Closed Open (after 2 to 4 min) Open (after 2 to 4 min) Turbomolecular pump On On On Off Off Forepump On On On Off Off Vent Delay PCB On On On On Off Embedded computer On On Off On Off Turbomolecular pump controller On On On Off Off Power supply, electron multiplier Off and conversion dynode Off Off On Off Power supply, 8 kV Off Off Off On Off PS1 power supply, +24 V On On On Off Off PS2 power supply, +5, ±15, ±24 V dc On On Off Off Off PS3 power supply, +36, -28 V dc On On Off Off Off Fan, turbomolecular pump On On On Off Off Fan, above manifold On On On Off Off Fan, center wall On On On Off Off Convectron gauge, foreline On On On On Off Convectron gauge, collision cell On On Off On Off Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 61 Table 4. On/Off status of mass spectrometer components and voltages (Sheet 2 of 2) Standby Off Mass spectrometer component Ion gauge On On Electronics service switch in Service Mode position Vacuum service switch in Service Mode position MS Main power circuit breaker switch in Off position Off Off Off 4 Tuning and Calibrating Tune parameters are instrument parameters that affect the intensity of the ion signal. Calibration parameters are instrument parameters that affect the mass accuracy and resolution of the mass spectrum. Tuning and calibrating the TSQ Quantum XLS or TSQ Quantum GC mass spectrometer automatically with TSQ EZ Tune uses perfluorotributylamine (FC-43) as the tuning and calibration compound. FC-43 resides in a vial inside the mass spectrometer. Contents • Displaying the FC-43 Mass Spectrum • Running Auto Tune and Calibration • Saving the Tune and Calibration Report Record the ion signal intensity of FC-43 (see Figure 32) just after you tune and calibrate the mass spectrometer. Periodically check the FC-43 ion signal. Re-tune and calibrate the mass spectrometer if the FC-43 ion signal falls below 50% of the tuned value. Also, re-tune and calibrate after switching between EI and CI modes or between positive and negative polarity modes. Note You may need to calibrate more often if you operate in H-SRM mode (as opposed to SRM mode only). Table 5 lists typical peaks that are observed in the FC-43 mass spectrum in EI, positive polarity mode. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 63 4 Tuning and Calibrating Displaying the FC-43 Mass Spectrum Table 5. Typically observed FC-43 peaks in EI, positive polarity mode m/z 69 m/z 100 m/z 114 m/z 119 m/z 131 m/z 169 m/z 219 m/z 264 m/z 314 m/z 352 m/z 402 m/z 414 m/z 464 m/z 502 m/z 614 Displaying the FC-43 Mass Spectrum The first step in tuning and calibrating the mass spectrometer is to display the FC-43 mass spectrum. Y To display the FC-43 mass spectrum 1. Choose Start > All Programs > Thermo Instruments > TSQ > TSQ Tune to open the EZ Tune window. 2. Choose a polarity mode. In this example the mass spectrometer is in positive polarity mode. If necessary, toggle the polarity button. Positive Negative Note For EI negative polarity mode, you might have to set the calibration gas flow to high. 3. Click the Define Scan button to display the Define Scan dialog box. 4. In the Define Scan dialog box, select or enter the following settings: • Scan type: Full Scan • Scan mode: Q1MS • Scan range entry mode: FM/LM 64 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 4 Tuning and Calibrating Displaying the FC-43 Mass Spectrum • First mass: 50 • Last mass: 650 • Scan time: 0.500 Figure 31. Define Scan dialog box 5. Click Apply to apply the settings. 6. Click the Calibration Gas button in the EZ Tune toolbar to turn on the flow of calibration gas into the ion source. .......... ..Cal Gas Off .........On 7. Click the Filament button in the EZ Tune toolbar to turn on the filament. .............Filament Off. . ....On 8. Choose Control > On to start the mass spectrometer scanning. 9. Observe the mass spectrum. If your mass spectrum looks very different from the one in Figure 32, see “Diagnostics and Troubleshooting” on page 129. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 65 4 Tuning and Calibrating Running Auto Tune and Calibration Figure 32. EZ Tune - EZ Workspace, showing the FC-43 mass spectrum in EI, positive polarity mode before tuning and calibrating. Running Auto Tune and Calibration Run the tune and calibration procedure after you obtain a good FC-43 ion signal. Y To tune and calibrate your mass spectrometer automatically in the EI, positive ion mode 1. Display the FC-43 positive ion mass spectrum as described in the previous section. 2. Click the System Tune and Calibration button (or choose Setup > System Tune and Calibration) to display the System Tune and Calibration dialog box. 66 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 4 Tuning and Calibrating Running Auto Tune and Calibration Figure 33. System Tune and Calibration dialog box 3. In the Compound list, select FC43 pos. ions. This automatically selects the positively charged FC-43 ions to be used for automatic tuning and calibrating. 4. Select Tune A as the tune algorithm. Note Tune A is the first choice of tune algorithm if there is a regular EI or CI ion volume installed in the ion source. Tune B is the first choice of tune algorithm if there is a closed EI ion volume installed. 5. Click Start to start the automatic tuning and calibration procedure. The Status box displays real-time messages about the system tune and calibration so that you can monitor the progress of each sub-procedure. After a sub-procedure is complete, the result is reported (for example, whether it passed or failed). At the end of the entire procedure, it displays a summary. • If errors occur during the automatic tuning and calibration procedure, go to step 6. • If the automatic tuning and calibration procedure finishes without errors, go to step 7. 6. If errors occur during the automatic tuning and calibration procedure, restore the previous mass spectrometer device settings and perform the tuning and calibration procedure again by completing the following steps: a. To restore the prior tuning and calibration settings, click Undo. b. To reload the prior tuning and calibration settings to the mass spectrometer, click Accept. c. Troubleshoot and correct the problem that caused the tuning and calibration procedure to fail. See “Tuning Issues” on page 143. d. Go to step 5 and restart the tuning and calibration procedure. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 67 4 Tuning and Calibrating Running Auto Tune and Calibration Figure 34. Typical parameter optimization plot 7. Click Accept to accept the results of the tuning and calibration procedure. After you accept the results of the tuning and calibration procedure, a message box asks whether you want to copy the positive ion tuning and calibration settings to the negative ion mode. • If you have already tuned and calibrated the instrument successfully in the negative ion mode, click No. (Do not copy the positive ion mode parameters to the negative ion mode.) • If you have not tuned and calibrated the instrument in the negative ion mode, click Yes. Note If you intend to perform high-sensitivity, negative-ion mass spectrum analysis, Thermo Fisher Scientific recommends that you also perform a full tune and calibration of the instrument in the negative ion mode. 8. Save the calibration file as follows: a. Click Save Calib. As to open the Save Calibration File dialog box. b. In the File Name box, enter a name for your calibration file. 68 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 4 Tuning and Calibrating Saving the Tune and Calibration Report c. Click Save to save the calibration file. The Save As dialog box appears. 9. Save the tune method file as follows: a. In the File Name box, enter a name for your tune method file. b. Click Save to save the tune method file. The mass spectrometer is now tuned and calibrated in the positive ion mode. Saving the Tune and Calibration Report You can save the information that appears in the Status box and in the parameter optimization plots as a PDF file. Examples of status information and parameter optimization plots from the tune and calibration report follow. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 69 4 Tuning and Calibrating Saving the Tune and Calibration Report Figure 35. Tune and calibration report, status page Quantum Tune Master - Tune and Calibration Results from System Tune and Calibration using FC43 Pos. Ions: Q1 and Q3 Tuning & Calibrating 10:55:29: 10:55:39: 10:55:41: 10:55:42: 10:56:02: 10:56:02: 10:56:07: 10:56:08: 10:56:12: 10:56:14: 10:56:20: 10:56:20: 10:56:20: 10:56:20: 10:56:26: 10:56:26: 10:56:26: 10:56:26: 10:56:32: 10:56:32: 10:56:32: 10:56:32: 10:56:38: 10:56:38: 10:56:38: 10:56:38: 10:56:45: 10:56:45: 10:56:45: 10:56:45: 10:56:47: 10:56:48: 10:57:04: 10:57:04: 10:57:10: 10:57:11: 10:57:16: 10:57:18: 10:57:24: 10:57:24: 10:57:24: 10:57:24: 10:57:30: 10:57:30: 10:57:30: 10:57:30: Tuning and Calibrating Q1 Tuning Q1MS at mass 69.00 m/z Opening resolution Adjusting resolution The adjusted resolution is -13.33 at the width 0.78 Coarse resolution done - Quick calibration The adjusted calibration of mass 69.0 is -0.88 Averaging Stopping Curve... Q1 Quadrupole Offset set to -0.85 for all reswidths Optimizing Lens 2 for ion 69.00 m/z Previous Setting = -7.00, New Setting = -0.80 Maximum Intensity = 1.04e+06 322 % Improvement Optimizing Lens 4 for ion 69.00 m/z Previous Setting = -10.00, New Setting = -46.55 Maximum Intensity = 1.61e+06 60 % Improvement Optimizing Lens 1-1 for ion 69.00 m/z Previous Setting = -5.00, New Setting = -0.86 Maximum Intensity = 1.93e+06 15 % Improvement Optimizing Lens 1-2 for ion 69.00 m/z Previous Setting = -21.90, New Setting = -5.00 Maximum Intensity = 2.43e+06 41 % Improvement Optimizing Lens 2-1 for ion 69.00 m/z Previous Setting = -8.45, New Setting = 3.92 Maximum Intensity = 2.56e+06 17 % Improvement Tuning Q1MS at mass 501.97 m/s Opening resolution Adjusting resolution The adjusted resolution is -14.38 at the width 0.78 Coarse resolution done - Quick calibration The adjusted calibration of mass 502.0 is -0.16 Averaging Stopping Curve... Q1 Quadrupole Offset set to -2.00 for all reswidths Optimizing Lens 2 for ion 501.97 m/z Previous Setting = -7.00, New Setting = -2.70 Maximum Intensity = 2.97e+05 223 % Improvement Optimizing Lens 1-2 for ion 501.97 m/z Previous Setting = -50.14, New Setting = -51.11 Maximum Intensity = 4.35e+05 6 % Improvement Optimizing Lens 2-1 for ion 501.97 m/z Signature: __________________________________________ May 09, 2007 11:17:28 70 TSQ Quantum XLS and TSQ Quantum GC User Guide Page 1 of 10 Thermo Scientific 4 Tuning and Calibrating Saving the Tune and Calibration Report Figure 36. Tune and calibration report, parameter optimization plots Quantum Tune Master - Tune and Calibration Optimizing Lens 2 for Q1MS 80 60 40 20 Mass 501.97m/z : 223 % Improvement Mass 218.99m/z : 94 % Improvement Mass 69.00m/z : 322 % Improvement 0 -50 -40 -30 -20 Lens 2 Voltage (V) Previous Setting Optimum Setting 100 R e la t iv e Int e ns it y R e la t iv e Int e ns it y Optimizing Lens 2 for Q3MS Previous Setting Optimum Setting 100 80 60 40 20 Mass 501.97m/z : 281 % Improvement Mass 218.99m/z : 57 % Improvement Mass 69.00m/z : 235 % Improvement 0 -10 0 -50 Optimizing Lens 4 for Q1MS 60 40 20 Mass 69.00m/z : 60 % Improvement -50 -40 -30 -20 Lens 4 Voltage (V) 60 40 20 Mass 69.00m/z : 15 % Improvement 0 -10 0 -10 40 20 Mass 69.00m/z : 6 % Improvement -6 -4 Lens 1-1 Voltage (V) -2 0 May 9, 2007 Previous Setting Optimum Setting 100 R e la t iv e Int e ns it y R e la t iv e Int e ns it y 60 -8 -6 -4 Lens 1-1 Voltage (V) Optimizing Lens 1-2 for Q1MS 80 -10 -8 May 9, 2007 Previous Setting Optimum Setting 0 0 May 9, 2007 80 Optimizing Lens 1-1 for Q3MS 100 -10 Previous Setting Optimum Setting 100 R e la t iv e Int e ns it y R e la t iv e Int e ns it y 80 0 -30 -20 Lens 2 Voltage (V) Optimizing Lens 1-1 for Q1MS Previous Setting Optimum Setting 100 -40 May 9, 2007 80 60 40 20 Mass 501.97m/z : 6 % Improvement Mass 218.99m/z : No Improvement Mass 69.00m/z : 41 % Improvement 0 -2 0 -250 -200 May 9, 2007 -150 -100 Lens 1-2 Voltage (V) -50 0 May 9, 2007 Y To save the tune and calibration report 1. In the System Tune and Calibration dialog box, click Save Report. The Save As dialog box appears. 2. Enter the name and the path of the report, and click Save. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 71 5 Changing Ionization Modes You can operate the TSQ Quantum XLS and TSQ Quantum GC mass spectrometers in either EI or CI ionization mode. Changing ionization modes requires changing ion volumes. It is not necessary to shut down the mass spectrometer to change ion volumes. The following sections describe how to change the ionization mode. Contents • Removing the Ion Volume • Installing the Ion Volume Removing the Ion Volume Tools Needed • Gloves, clean, lint- and powder-free • Insert/removal (I/R) tool and guide bar Frequency When you change ionization modes or as needed to clean the ion volume Y To remove the ion volume 1. Install the guide bar. a. With the guide ball track facing left, insert the guide bar into the entry housing. See Figure 37. b. Push the guide bar in as far as it will go; then rotate it 90° clockwise to lock the guide bar in the entry housing. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 73 5 Changing Ionization Modes Removing the Ion Volume Figure 37. Insertion/removal (I/R) tool and guide bar I/R tool Guide ball Guide ball hole First stop Guide ball track Guide bar Bayonet lock 2. Prepare the inlet valve and I/R tool for insertion. a. Make sure the inlet valve is closed. Figure 38 shows the inlet valve lever is down for closed. b. Loosen the inlet valve knob counter-clockwise and remove the inlet valve plug. The inlet valve plug prevents air from entering the vacuum manifold in case the inlet valve is inadvertently opened. c. Turn the I/R tool to the unlock position in position to accept the ion volume. 74 TSQ Quantum XLS and TSQ Quantum GC User Guide , which indicates the I/R tool is Thermo Scientific 5 Changing Ionization Modes Removing the Ion Volume Figure 38. Inlet valve components Inlet valve knob Inlet valve plug Entry housing Inlet valve lever (down is closed, up is open) 3. Choose Start > All Programs > Thermo Instruments > TSQ > TSQ Tune to open the EZ Tune window. 4. Click the Probe appears (Figure 39). button in the EZ Tune toolbar. The Insert Probe message Figure 39. Insert Probe message Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 75 5 Changing Ionization Modes Removing the Ion Volume 5. Inset the I/R tool into the inlet valve. a. Insert the guide ball into the guide ball hole. b. Slide the I/R tool forward into the inlet valve until the guide ball is at the guide bar’s first stop (see Figure 40). c. Tighten the inlet valve knob clockwise to ensure a leak-tight seal. Figure 40. I/R tool at the first stop on guide bar and the inlet valve knob tightened I/R tool 76 First stop of guide bar TSQ Quantum XLS and TSQ Quantum GC User Guide Inlet valve knob Thermo Scientific 5 Changing Ionization Modes Removing the Ion Volume 6. Click OK. The forepump evacuates the inlet valve. Wait until the safe to insert probe message appears, and then click OK. Figure 41. Safe to insert the probe message 7. Once evacuation is complete, pull the inlet valve lever up to open the inlet valve. Figure 42. I/R tool at first stop and inlet valve lever up I/R tool Thermo Scientific First stop of guide bar Inlet valve lever TSQ Quantum XLS and TSQ Quantum GC User Guide 77 5 Changing Ionization Modes Removing the Ion Volume 8. Remove the ion volume. a. Slide the I/R tool into the vacuum manifold until the tip of the I/R tool is fully inserted into the ion volume holder. The head of the arrow on the I/R tool (Figure 44), when viewed through the window of the ion source manifold, should not be visible. Figure 43. I/R tool inserted into the inlet valve b. Turn the I/R tool handle counterclockwise to put the I/R tool into lock position . Listen for a click, which indicates that the handle is fully engaged in the lock position and is holding the ion volume. c. Withdraw the I/R tool (with the ion volume attached) until the guide ball reaches the first stop (see Figure 42). d. Pull the lever down to close the inlet valve. 78 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 5 Changing Ionization Modes Removing the Ion Volume CAUTION Do not withdraw the I/R tool beyond the point where the guide ball reaches the first stop in the guide bar. Close the inlet valve first. Otherwise, the system vents to the atmosphere. e. Loosen the inlet valve knob by turning it counterclockwise to release the seal. f. Continue withdrawing the I/R tool completely from the inlet valve by sliding the I/R tool through the guide ball track in the guide bar. CAUTION Because the ion volume might be too hot to touch, let it cool to room temperature before handling it. 9. Remove the ion volume from the I/R tool. See Figure 44. a. Wearing clean gloves, press the ion volume forward into the tip of the I/R tool and rotate it to disconnect the bayonet pins from the pin guides. b. Pull the ion volume out of the I/R tool. Figure 44. Ion volume, ion volume holder, and I/R tool Arrow Bayonet pin Bayonet lock Arrow I/R tool Bayonet pin guide Ion volume holder Spring washer Ion volume 10. To clean the ion volume, use the instructions in “Cleaning Stainless Steel Parts” on page 113. If you are cleaning a CI ion volume, be sure to clean out the small electron entrance hole. Aluminum oxide can get trapped in this hole, which can adversely affect sensitivity. Use a dental pick or old syringe needle to clean the hole. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 79 5 Changing Ionization Modes Installing the Ion Volume Installing the Ion Volume You install an ion volume after cleaning or to change ionization modes. Y To install the ion volume Note Wear clean, lint- and powder- free gloves when you handle a clean ion volume. 1. Place the clean ion volume on the I/R tool with the arrows aligned. See Figure 44. CAUTION Make sure the arrows on the I/R tool and ion volume are aligned to avoid damage to the ion source. 2. Turn the I/R tool handle to the lock position . 3. Install the guide bar. a. With the guide ball track facing left, insert the guide bar into the entry housing (see Figure 37). b. Push the guide bar in as far as it will go, and then rotate it 90° clockwise to lock the guide bar in the entry housing. 4. Prepare the inlet valve for insertion. a. Make sure the inlet valve is closed. Figure 38 shows the inlet valve lever is down for closed. b. Loosen the inlet valve knob counter-clockwise and remove the inlet valve plug. Remove the inlet valve plug. The inlet valve plug prevents air from entering the vacuum manifold in case the inlet valve is inadvertently opened. 5. Choose Start > All Programs > Thermo Instruments > TSQ > TSQ Tune to open the EZ Tune window. 6. Click the Probe appears. See Figure 39. button in the EZ Tune toolbar. The Insert Probe message 7. Inset the I/R tool into the inlet valve. a. Insert the guide ball into the guide ball hole. b. Slide the I/R tool forward into the inlet valve until the guide ball is at the guide bar’s first stop. See Figure 40. c. Tighten the inlet valve knob clockwise to ensure a leak-tight seal. 8. Click OK. The forepump evacuates the inlet valve. Wait for the safe to insert probe message to appear (Figure 41); then click OK. 9. Once evacuation is complete, pull the inlet valve lever up to open the inlet valve. 80 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 5 Changing Ionization Modes Installing the Ion Volume 10. Install the ion volume. a. Slide the I/R tool and ion volume assembly into the vacuum manifold until the ion volume assembly is fully inserted and seated into the ion source block. Listen for a click, which indicates that the ion volume has connected with the ion source block. b. Turn the I/R tool handle to the unlock position volume from the I/R tool. to release the ion Figure 45. Ion volume seated in the ion source block Ion source block Ion volume 11. Verify that the ion volume is fully seated in the ion source block: • Withdraw the I/R tool away from the ion volume about 2.5 cm (1 in.), and turn the I/R tool handle to the lock position. • Slide the I/R tool back into the vacuum manifold until the end of the I/R tool just touches the ion volume. • Test that the I/R tool does not go into the inlet valve completely, which indicates that the ion volume is seated properly. 12. Remove the I/R tool. a. Withdraw the I/R tool until the guide ball reaches the first stop (see Figure 42). b. Close the inlet valve by pulling the inlet valve lever down (see Figure 40). CAUTION Do not withdraw the I/R tool beyond the point where the guide ball reaches the first stop in the guide bar. Close the inlet valve first. Otherwise, the system vents to the atmosphere. c. Loosen the inlet valve knob by turning it counter-clockwise. d. Continue withdrawing the I/R tool completely from the inlet valve by sliding the I/R tool through the guide ball track in the guide bar. 13. Remove the guide bar by rotating it 90° counter-clockwise and sliding it out of the entry housing. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 81 5 Changing Ionization Modes Installing the Ion Volume 14. Replace the inlet valve plug. Orient the plug to indicate whether an EI or CI ion volume is installed. 15. Tighten the inlet valve knob clockwise to create a leak-tight seal. 16. (Optional) To prevent the inlet valve from being opened accidentally, pull free and remove the inlet valve lever. 82 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Maintenance This chapter describes routine maintenance procedures that you must perform to ensure optimum performance of the TSQ Quantum XLS or TSQ Quantum GC mass spectrometer. Optimum performance of the mass spectrometer depends on the maintenance of all parts of the instrument. You are responsible for maintaining your instrument properly by performing the maintenance procedures on a regular basis. Note When you perform maintenance procedures, be methodical; always wear clean, lint-free gloves when handling the components of the ion source; always place the components on a clean, lint-free surface; and never overtighten a screw or use excessive force. Table 6 lists routine and infrequent mass spectrometer maintenance procedures. For instructions on maintaining the GC or autosampler, refer to the manuals that come with the GC or autosampler. Table 6. Maintenance procedures (Sheet 1 of 2) Mass spectrometer component Procedure Frequency Procedure location Ion source Cleaning the ion volume As needed* Page 87 Ion source Cleaning the lenses As needed* Page 88 (TSQ Quantum XLS), page 95 (TSQ Quantum GC) Ion source Cleaning the entire ion As needed* source Page 107(TSQ Quantum XLS), page 110 (TSQ Quantum GC) Ion source Replacing the filament Inlet valve Replacing the ball valve If there is an air seal leak in the inlet valve Calibration compound Adding calibration compound Thermo Scientific If the filament fails Page 102 (TSQ Quantum XLS), page 105 (TSQ Quantum GC) Page 120 If EZ Tune error Page 117 message indicates low intensity of calibration gas ions TSQ Quantum XLS and TSQ Quantum GC User Guide 83 6 Maintenance Table 6. Maintenance procedures (Sheet 2 of 2) Mass spectrometer component Procedure location Procedure Frequency Gas chromatograph Replacing the capillary column If chromatographic Page 122 separation is bad or if a different stationary phase is needed for the application Q0 ion optics Cleaning the Q0 quadrupole and L11 and L12 lenses** As needed* Mass analyzer Cleaning the Q1, Q2, and Q3 quadrupoles and lenses** As needed* Forepump Purging the forepump pump oil If pump oil is cloudy Forepump Adding pump oil If pump oil level is Manufacturer’s low documentation Forepump Changing the pump oil Every 4 months or if pump oil is cloudy and discolored Ion detection system Replacing the electron multiplier assembly** Electronic modules Replacing an electronic If electronic module** module fails PCBs Replacing a PCB** Manufacturer’s documentation Manufacturer’s documentation If noise in spectrum is excessive or proper electron multiplier gain cannot be achieved If PCB fails *The frequency of cleaning the components of the mass spectrometer depends on the types and amounts of samples and solvents that are introduced into the instrument. Cleaning of the Q0, Q1, Q2, and Q3 quadrupoles is rarely (if ever) required. **A Thermo Fisher Scientific Field Service Engineer must perform this maintenance procedure. 84 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Cleaning Ion Source Components Contents • Cleaning Ion Source Components • Replacing the Filament of the TSQ Quantum XLS Ion Source • Replacing the Filament of the TSQ Quantum GC Ion Source • Disassembling and Reassembling the TSQ Quantum XLS Ion Source Completely • Disassembling and Reassembling the TSQ Quantum GC Ion Source Completely • Maintaining the Forepump • Adding Calibration Compound • Replacing the Ball Valve Seal • Removing and Installing a GC Capillary Column Cleaning Ion Source Components An important part of maintaining your TSQ Quantum XLS or TSQ Quantum GC mass spectrometer is making sure that the ion source components are clean. Follow the cleaning procedures in this section to clean stainless steel and non-stainless steel parts. When your mass spectrometer is clean and in good working order, perform benchmark tests and record the results. When the tested performance of your system decreases significantly from your benchmark test results, clean the ion volume. If this does not restore performance, clean the lenses. How often you clean the ion source depends on the types and amounts of samples and solvents you introduce into the system. In general, the closer a component is to the sample introduction point, the more rapidly the component becomes dirty. For example, you clean the ion volume more often than other parts. If you just want to change or clean the ion volumes, you do not need to shut down the system. Most parts can be removed and disassembled by hand. Make sure you have all the tools needed before starting each procedure. Figure 46 shows an exploded view of the ion source assembly. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 85 Figure 46. Ion source assembly of the TSQ Quantum XLS, exploded and assembled views 86 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific Figure 47. Ion source assembly of the TSQ Quantum GC, exploded and assembled views 87 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Cleaning Ion Source Components Cleaning Ion Volumes You do not need to vent the mass spectrometer to atmosphere to clean the ion volume. Y To clean the ion volume 1. Remove the ion volume. See “Removing the Ion Volume” on page 73. CAUTION Burn Hazard. The ion volume might be hot. Allow the ion volume to cool to room temperature before touching it. 2. Clean the ion volume. See “Cleaning Stainless Steel Parts” on page 113. If you are cleaning a CI ion volume, be sure to clean out the small electron entrance hole. Aluminum oxide can get trapped in this hole, which can adversely affect sensitivity. Use a dental pick or old syringe needle to clean the hole. 3. Reinstall the ion volume. See“Installing the Ion Volume” on page 80. Cleaning Lenses of the TSQ Quantum XLS Ion Source If cleaning the ion volume does not restore system performance, clean the ion source lenses. Y To clean the ion source lenses 1. Shut down and vent the system. See “Shutting Down the System Completely” on page 53. CAUTION Shock Hazard. Unplug the TSQ Quantum XLS mass spectrometer before proceeding. CAUTION Burn Hazard. The ion source might be hot. Allow the ion source to cool to room temperature before touching it. 2. Remove the ion source. See “Removing the TSQ Quantum XLS Ion Source” on page 89. 3. Remove the ion source lens assemblies from the ion source and disassemble it. See “Removing the L1, L2, L3 Lens Assembly and the Q00 Quadrupole Lens Assembly” on page 91. 4. Clean the lenses and the spacers. See “Cleaning Stainless Steel Parts” on page 113 and “Cleaning Non-Stainless Steel or Hybrid Part” on page 115, respectively. 5. Reassemble L1, L2, L3 lens assembly and install it and the Q00 quadrupole onto the ion source. See “Reassembling the L1, L2, L3 Lens Assembly” on page 93. 88 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Cleaning Ion Source Components 6. Reinstall the ion source into the mass spectrometer. See “Reinstalling the TSQ Quantum XLS Ion Source” on page 94. 7. Restart the system. See “Starting Up the System after a Complete Shutdown” on page 55. Removing the TSQ Quantum XLS Ion Source Remove the ion source to clean the lenses or replace the filament. Tools Needed • Gloves, cleanroom grade (P/N 23827-0008 and 23827-0009) • Lint-free cloth Frequency As needed to perform ion source maintenance Y To remove the ion source CAUTION Do not remove the ion source without first pulling back the GC capillary column, or else the capillary column might break. 1. Shut down and vent the TSQ Quantum XLS mass spectrometer. See “Shutting Down the System Completely” on page 53. CAUTION Shock Hazard. Unplug the TSQ Quantum XLS mass spectrometer before proceeding. 2. Pull back the capillary column. a. Lower the oven, injector, and transfer line temperatures to 30 °C and allow them to cool before continuing. CAUTION Burn Hazard. The GC oven, injector, and transfer line are hot. Allow them to cool to room temperature before touching them. b. Once the oven, injector, and transfer line are cool, turn off the gas chromatograph. c. Loosen the transfer line nut. See Figure 64 on page 123. d. Pull back the column. (You can first mark the column’s position with white out or something similar.) 3. Prepare a clean work area by covering the area with lint-free cloth. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 89 6 Maintenance Cleaning Ion Source Components 4. Undo the two latches that secure the lid of the ion source vacuum manifold, and open the lid. 5. Disconnect the connectors from the lead pins at the EI/CI Source PCB, and L1, L2, L3 lens assembly. Figure 48. TSQ Quantum XLS ion source, installed Q0 quadrupole mount Lens L1, L2, L3 connector EI/CI Source PCB connector Thumbscrew Transfer line Thumbscrew CAUTION Burn Hazard. The ion source might be hot. Allow the ion source to cool to room temperature before touching it. Note Wear clean, lint- and powder- free gloves when you handle the ion source. 6. While holding the ion source assembly, loosen the two thumbscrews that secure the ion source assembly to the Q0 quadrupole mount. 7. Pull the ion source assembly away from the Q0 quadrupole mount and 2 mm to the right to clear the transfer line bellows. 8. Slide the ion source off the magnet yoke. 90 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Cleaning Ion Source Components 9. Place the ion source and magnet yoke on a clean, lint-free cloth. 10. Close the lid of the ion source vacuum manifold. Removing the L1, L2, L3 Lens Assembly and the Q00 Quadrupole Lens Assembly The ion source includes the L1, L2, L3 lens assembly and the Q00 quadrupole lens assembly. You must remove and disassemble the L1, L2, L3 lens assembly to clean the lenses. A retainer clip fastens the L1, L2, L3 lens assembly and the Q00 quadrupole lens assembly to the ion source block. To remove the ion source lens assemblies 1. Wearing clean, lint- and powder- free gloves, unscrew the threaded hexagonal standoff and remove the retainer clip that secures the lens assembly to the ion source block. See Figure 49. 2. Remove the Q00 quadrupole lens assembly and the L1, L2, L3 lens assembly from the heater cartridges of the ion source. Place them on a clean surface. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 91 6 Maintenance Cleaning Ion Source Components Figure 49. L1, L2, L3 lens assembly and Q00 quadrupole lens assembly removed from the ion source Q00 quadrupole lens assembly L1, L2, L3 lens assembly Ion source Retainer clip Threaded standoff Disassembling the L1, L2, L3 Lens Assembly Y To disassemble the L1, L2, L3 lens assembly 1. Remove the lens retainer clip by pinching the ends with your fingers or a pair of tweezers. See Figure 50. 2. Remove the lenses and spacers from the lens holder. 3. Place the components on a clean surface. 92 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Cleaning Ion Source Components Figure 50. L1, L2, L3 lens assembly, exploded and assembled views Lens holder Lens L3 Spacer Lens L2 Spacer Lens L1 Lens retainer clip Note To clean the ion source lenses, follow the procedure in “Cleaning Stainless Steel Parts” on page 113. To clean the remaining parts, follow the procedure in “Cleaning Non-Stainless Steel or Hybrid Part” on page 115. Reassembling the L1, L2, L3 Lens Assembly Ensure that the lenses are clean and dry before you reassemble the lens assembly. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 93 6 Maintenance Cleaning Ion Source Components Y To reassemble the L1, L2, L3 lens assembly 1. Wearing clean, lint- and powder- free gloves, reinstall the lenses and spacers in the lens holder in the order and orientation shown in Figure 50, starting with lens L3. 2. Reinstall the lens clip by pinching the ends with your fingers or a pair of tweezers and seating it in the lens holder. 3. Insert the lens alignment tool (in the TSQ Quantum XLS Accessory Kit) into the lens assembly and align the lenses Reinstalling the Ion Source Lens Assemblies Y To reinstall the ion source lens assemblies onto the ion source 1. Wearing clean, lint- and powder- free gloves, insert the three heater cartridges of the ion source through their corresponding holes in the L1, L2, L3 lens assembly. See Figure 49. 2. Insert the three heater cartridges of the ion source through their corresponding holes in the Q00 quadrupole lens assembly. Verify the correct orientation of the guide pin hole and the retainer clip groove on the Q00 quadrupole lens assembly. 3. Use the retainer clip and threaded standoff to secure the lens assemblies to the ion source. IMPORTANT For accurate temperature readings of the heater block, fully screw the threaded standoff into the ion source to ensure contact between the temperature sensor with the heater block. Reinstalling the TSQ Quantum XLS Ion Source Y To reinstall the ion source into the vacuum manifold 1. Wearing clean, lint- and powder- free gloves, place the ion source onto the magnet yoke. 2. Position the ion source in the vacuum manifold and ensure the following: • The transfer line is seated in the sample inlet aperture in the ion source. • The guide pin on the Q0 quadrupole mount inserts into the guide pin groove on the Q00 lens assembly. • The two thumbscrews are aligned with the screw holes in the Q0 quadrupole mount. See Figure 48. 3. Secure the ion source to the Q0 quadrupole mount by alternately tightening each thumbscrew one-half turn at a time. Make sure there is no play in the ion source. 4. Align and reconnect the 8-pin connector to the lead pins on the EI/CI Source PCB. See Figure 48. 5. Align the 3-pin connector such that the side with the beveled edge is closest to the L3 lead pin and the side with the rounded corners is closest to the L1 lead pin. 94 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Cleaning Ion Source Components 6. Reconnect the 3-pin connector to the lead pins on the L1, L2, and L3 lenses. See Figure 48. 7. Reinsert the capillary column into the ion source. a. Using the I/R tool, remove the ion volume. See “Removing the Ion Volume” on page 73. b. Push the capillary column in until you can see it in the ion source. c. Pull the column back just far enough that you cannot see it. d. Tighten the transfer line nut and transfer line union. e. Using the I/R tool, install the ion volume. See “Installing the Ion Volume” on page 80. 8. Close and secure the cover to the ion source vacuum manifold. Cleaning the Lenses of the TSQ Quantum GC Ion Source If cleaning the ion volume does not restore system performance, clean the ion source lenses. Note Lens L4 requires cleaning less often than lens L1, L2, and L3. Y To clean the ion source lenses 1. Shut down and vent the system. See “Shutting Down the System Completely” on page 49. CAUTION Shock Hazard. Unplug the TSQ Quantum GC before proceeding. CAUTION Burn Hazard. The ion source might be hot. Allow the ion source to cool to room temperature before touching it. 2. Remove the ion source. See “Removing the TSQ Quantum XLS Ion Source” on page 89. 3. Remove the ion source lens assembly from the ion source and disassemble it. See “Removing the L1, L2, L3 Lens Assembly and the Q00 Quadrupole Lens Assembly” on page 91. 4. Clean the lenses and the spacers. See “Cleaning Stainless Steel Parts” on page 113 and “Cleaning Non-Stainless Steel or Hybrid Part” on page 115, respectively. 5. Reassemble the ion source lens assembly and install it onto the ion source. See “Reassembling the L1, L2, L3 Lens Assembly” on page 93. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 95 6 Maintenance Cleaning Ion Source Components 6. Reinstall the ion source into the mass spectrometer. See “Reinstalling the TSQ Quantum XLS Ion Source” on page 94. 7. Restart the system. See “Starting Up the System after a Complete Shutdown” on page 51. Removing the TSQ Quantum GC Ion Source Remove the ion source to clean the lenses or replace the filament. Tools Needed • Gloves, cleanroom grade (P/N 23827-0008 and 23827-0009) • Lint-free cloth Frequency As needed to perform ion source maintenance Y To remove the ion source CAUTION Do not remove the ion source without first pulling back the capillary column, or else the capillary column might break. 1. Shut down and vent the TSQ Quantum GC mass spectrometer. See “Shutting Down the System Completely” on page 49. CAUTION Shock Hazard. Unplug the TSQ Quantum GC mass spectrometer before proceeding. 2. Pull back the capillary column. a. Lower the oven, injector, and transfer line temperatures to 30 °C and allow them to cool before continuing. CAUTION Burn Hazard. The GC oven, injector, and transfer line are hot. Allow them to cool to room temperature before touching them. b. Once the oven, injector, and transfer line are cool, turn off the gas chromatograph. c. Loosen the transfer line nut. See Figure 64 on page 123. d. Pull back the column. (You can first mark the column’s position with white out or something similar.) 3. Prepare a clean work area by covering the area with lint-free cloth. 4. Undo the two latches that secure the lid of the ion source vacuum manifold, and open the lid. 96 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Cleaning Ion Source Components 5. Disconnect the connectors from the lead pins at the EI/CI Source PCB, lens L1, L2, L3 assembly, and lens L4 assembly. See Figure 48. Figure 51. TSQ Quantum GC ion source, installed Q0 quadrupole mount Lens L4 connector Lens L1, L2, L3 connector EI/CI Source PCB connector Thumbscrew Transfer line Thumbscrew CAUTION Burn Hazard. The ion source might be hot. Allow the ion source to cool to room temperature before touching it. Note Wear clean, lint- and powder- free gloves when you handle the ion source. 6. While holding the ion source assembly, loosen the two thumbscrews that secure the ion source assembly to the Q0 quadrupole. 7. Pull the ion source assembly away from the Q0 quadrupole and 2 mm to the right to clear the transfer line bellows. 8. Slide the ion source off the magnet yoke. 9. Place the ion source and magnet yoke on a clean, lint-free cloth. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 97 6 Maintenance Cleaning Ion Source Components 10. Close the lid of the ion source vacuum manifold. Removing the Ion Source Lens Assembly The ion source lens assembly includes lens L1, L2, L3, and L4. You must remove and disassemble the ion source lens assembly to clean the lenses. A retainer clip fastens the lens assembly to the ion source block. To remove the ion source lens assembly 1. Wearing clean, lint- and powder- free gloves, unscrew the threaded hexagonal standoff and remove the retainer clip that secures the lens assembly to the ion source block. See Figure . 2. Pull the lens assembly out of the ion source. 3. Place the ion source and lens assembly on a clean surface. Figure 52. Lens assembly removed from the ion source Lens assembly Ion source Retainer clip Threaded standoff Disassembling the Ion Source Lens Assembly Y To disassemble the lens assembly 1. Pull the L1, L2, L3 lens assembly from the L4 lens assembly. 98 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Cleaning Ion Source Components Figure 53. Ion source lens assembly separated into L1, L2, L3 lens assembly (left) and L4 lens assembly (right) L1, L2, L3 lens assembly L4 lens assembly 2. Disassemble the L1, L2, L3 lens assembly. a. Remove the lens clip by pinching the ends with your fingers or a pair of tweezers. b. Remove the lenses and spacers from the lens holder. c. Place the components on a clean surface. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 99 6 Maintenance Cleaning Ion Source Components Figure 54. L1, L2, L3 lens assembly, exploded and assembled views Lens holder Lens L3 Spacer Lens L2 Spacer Lens L1 Lens retainer clip 3. Disassemble the L4 lens assembly. a. Remove the lens clip by pinching the ends with your fingers or a pair of tweezers. b. Remove the lens L4 from the lens holder. c. Place the components on a clean surface. 100 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Cleaning Ion Source Components Figure 55. L4 lens assembly, exploded view Lens clip Lens L4 Lens holder Note To clean the ion source lenses, follow the procedure in “Cleaning Stainless Steel Parts” on page 113. Reassembling the Ion Source Lens Assembly Ensure that the lenses are clean and dry before you reassemble the lens assembly. Y To reassemble the ion source lens assembly 1. Wearing clean, lint- and powder- free gloves, reassemble the L4 lens assembly. a. Insert lens L4 into the lens holder. See Figure 55. b. Install the lens clip by pinching the ends with your fingers or a pair of tweezers. Seat the lens clip in the lens holder. 2. Reassemble the L1, L2, L3 lens assembly. See Figure 54. a. Reinstall the lenses and spacers in the lens holder in the order and orientation shown in Figure 54. b. Reinstall the lens clip by pinching the ends with your fingers or a pair of tweezers and seating it in the lens holder. c. Insert the lens alignment tool (in the TSQ Quantum GC Accessory Kit) into the lens assembly and align the lenses 3. Insert the L4 lens assembly into the L1, L2, L3 lens assembly. Align the lead pins. See Figure 53. Reinstalling the Ion Source Lens Assembly Y To reinstall the ion source lens assembly onto the ion source 1. Wearing clean, lint- and powder- free gloves, insert the lens assembly into the ion source. See Figure 53. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 101 6 Maintenance Replacing the Filament of the TSQ Quantum XLS Ion Source 2. Use the retainer clip and threaded standoff to secure the lens assembly to the ion source. See Figure . IMPORTANT For accurate temperature readings of the heater block, fully screw the threaded standoff into the ion source to ensure contact between the temperature sensor with the heater block. Reinstalling the Ion Source Y To reinstall the ion source into the vacuum manifold 1. Wearing clean, lint- and powder- free gloves, place the ion source onto the magnet yoke. 2. Position the ion source in the vacuum manifold and ensure the following: • The transfer line is seated in the sample inlet aperture in the ion source. • The two thumbscrews are aligned with the screw holes in the Q0 quadrupole mount. See Figure 48. 3. Secure the ion source to the Q0 quadrupole mount by alternately tightening each thumbscrew one-half turn at a time. Make sure there is no play in the ion source. 4. Reconnect the connectors to the lead pins on the EI/CI Source PCB, lens L1, L2, L3 assembly (the orientation is not important), and lens L4 assembly. See Figure 48. 5. Reinsert the capillary column into the ion source. a. Using the I/R tool, remove the ion volume. See “Removing the Ion Volume” on page 69. b. Push the column in until you can see it through the inlet valve. c. Pull the column back just far enough that you cannot see it. d. Tighten the transfer line nut and transfer line union. e. Using the I/R tool, install the ion volume. See “Installing the Ion Volume” on page 76. 6. Close and secure the cover to the ion source vacuum manifold. Replacing the Filament of the TSQ Quantum XLS Ion Source The number of ions produced in the ion source is approximately proportional to the filament emission current. If ion production is lacking, you might have to replace the filament. If the measured emission current is substantially less than the value that the emission current is set to, or if the measured emission current decreases over time, then the filament has failed or is failing and requires replacement. 102 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Replacing the Filament of the TSQ Quantum XLS Ion Source See Figure 46 on page 86 and Figure 56 on page page 104 for the location of the ion source components. Tools Needed • Filament (P/N 120320-0030) • Gloves, cleanroom grade (P/N 23827-0008 and 23827-0009) • Lint-free cloth Frequency If filament fails Y To replace the ion source filament 1. Prepare a clean work area by covering the area with lint-free cloth. 2. Shut down and vent the TSQ Quantum XLS mass spectrometer. See “Shutting Down the System Completely” on page 53. CAUTION Shock Hazard. Unplug the TSQ Quantum XLS mass spectrometer before proceeding. 3. Remove the ion source. See “Removing the TSQ Quantum XLS Ion Source” on page 89. 4. Wearing clean, lint- and powder- free gloves, remove the ion source from the magnet yoke. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 103 6 Maintenance Replacing the Filament of the TSQ Quantum XLS Ion Source Figure 56. Disassembling the TSQ Quantum XLS ion source to replace the filament Filament retainer clip Filament Centering ring Heater ring and lens assemblies Heater ring and lens assemblies retainer clip Ion source block and EI/CI Source PCB Threaded standoff 5. Unscrew the threaded standoff and remove the retainer clip that secures the heater ring and lens assemblies to the ion source block. See Figure 56. 6. Pull the heater ring and lens assemblies off of the cartridge heaters on the ion source block. Place them on a clean surface. 7. Remove the retainer clip that secures the filament and centering ring to the ion source block. 8. Remove the filament and centering ring from the ion source block. Note Now is a good time to clean the ion source block and lenses. Use the procedure described in “Cleaning Stainless Steel Parts” on page 113 to clean the ion source block and lenses. 9. Inspect and install a new filament (P/N 120320-0030, in the TSQ Quantum XLS Accessory Kit). a. Verify that the filament wire is centered in the electron lens hole. b. Insert the filament into the centering ring. 104 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Replacing the Filament of the TSQ Quantum GC Ion Source c. Align the filament leads with the EI/CI Source PCB connectors and gently press the leads into the connectors. Normally, there is a small gap (about 0.016 in.) between the filament and the connectors. The gap allows the ceramic centering ring to properly position and align the electron lens hole with the ion volume. d. Secure the filament and centering ring with the retainer clip. 10. Press the heater ring and lens assemblies onto the cartridge heaters on the ion source block. 11. Use the retainer clip and threaded standoff to secure the lens assemblies to the ion source. IMPORTANT For accurate temperature readings of the heater block, fully screw the threaded standoff into the ion source to ensure contact between the temperature sensor with the heater block. 12. Reinstall the ion source onto the magnet yoke. 13. Reinstall the ion source into the vacuum manifold. See “Reinstalling the TSQ Quantum XLS Ion Source” on page 94. Restart the system. See “Starting Up the System after a Complete Shutdown” on page 55. Replacing the Filament of the TSQ Quantum GC Ion Source The number of ions produced in the ion source is approximately proportional to the filament emission current. If ion production is lacking, you might have to replace the filament. If the measured emission current is substantially less than the value that the emission current is set to, or if the measured emission current decreases over time, then the filament has failed or is failing and requires replacement. See Figure 46 on page 86 and Figure 56 on page page 104 for the location of the ion source components.To replace the ion source filament Tools Needed • Filament (P/N 120320-0030) • Gloves, cleanroom grade (P/N 23827-0008 and 23827-0009) • Lint-free cloth Frequency If filament fails 1. Prepare a clean work area by covering the area with lint-free cloth. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 105 6 Maintenance Replacing the Filament of the TSQ Quantum GC Ion Source 2. Shut down and vent the TSQ Quantum GC. See “Shutting Down the System Completely” on page 49. CAUTION Shock Hazard. Unplug the TSQ Quantum GC before proceeding. 3. Remove the ion source. See “Removing the TSQ Quantum GC Ion Source” on page 96. 4. Wearing clean, lint- and powder- free gloves, remove the ion source from the magnet yoke. Figure 57. Disassembling the ion source to replace the filament Filament retainer clip Filament retainer clip Filament Centering ring Filament Centering ring Heater ring and lens assembly Heater ring and lens assembly retainer clip Ion source block and EI/CI Source PCB Threaded standoff 5. Unscrew the threaded standoff and remove the retainer clip that secures the heater ring and lens assembly to the ion source block. See Figure 56. 6. Pull the heater ring and lens assembly out of the ion source block. 7. Remove the retainer clip that secures the filament and centering ring to the ion source block. 106 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Disassembling and Reassembling the TSQ Quantum XLS Ion Source Completely 8. Remove the filament and centering ring from the ion source block. Note Now is a good time to clean the ion source block. Use the procedure described in “Cleaning Stainless Steel Parts” on page 113 to clean the ion source block. 9. Inspect and install a new filament (P/N 120320-0030, in the TSQ Quantum GC Accessory Kit). a. Verify that the filament wire is centered in the electron lens hole. b. Insert the filament into the centering ring. c. Seat the filament on the EI/CI Source PCB. d. Secure the filament with the retainer clip. 10. Press the heater ring and lens assembly onto the ion source block. 11. Use the retainer clip and threaded standoff to secure the lens assembly to the ion source. See Figure 56. IMPORTANT For accurate temperature readings of the heater block, fully screw the threaded standoff into the ion source to ensure contact between the temperature sensor with the heater block. 12. Reinstall the ion source onto the magnet yoke. 13. Reinstall the ion source into the vacuum manifold. See “Reinstalling the TSQ Quantum XLS Ion Source” on page 94. 14. Restart the system. See “Starting Up the System after a Complete Shutdown” on page 51. Disassembling and Reassembling the TSQ Quantum XLS Ion Source Completely Disassemble the ion source completely to clean the ion source block or to replace the EI/CI Source PCB. See Figure 58 for the location of the ion source components. Tools Needed • Gloves, cleanroom grade (P/N 23827-0008 and 23827-0009) • Lint-free cloth Frequency As needed Y To disassemble the ion source completely 1. Prepare a clean work area by covering the area with lint-free cloth. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 107 6 Maintenance Disassembling and Reassembling the TSQ Quantum XLS Ion Source Completely 2. Shut down and vent the TSQ Quantum XLS. See“Shutting Down the System Completely” on page 49. CAUTION Shock Hazard. Unplug the TSQ Quantum XLS mass spectrometer before proceeding. 3. Wearing clean, lint- and powder- free gloves, remove the ion source. See “Removing the TSQ Quantum XLS Ion Source” on page 89. 4. Remove the ion source from the magnet yoke. Figure 58. TSQ Quantum XLS ion source, disassembled Filament retainer clip Q00 quadrupole lens assembly Filament Heater ring Centering ring Ion source block L1, L2, L3 lens assembly Threaded standoff Heater ring and lens assemblies retainer clip EI/CI Source PCB Base studs 5. Pull the Q00 quadrupole lens assembly and the L1, L2, L3 lens assembly off the ion source. 6. Pull the heater ring off the ion source. 7. Unscrew and remove the three base studs. 108 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Disassembling and Reassembling the TSQ Quantum XLS Ion Source Completely CAUTION Do not pull the EI/CI Source PCB out of the ion source block. This might damage the EI/CI Source PCB. 8. Remove the EI/CI Source PCB. a. Place the ion source on a clean surface with the cartridge heaters down and the EI/CI Source PCB up. b. Press down on the ion source block to separate it from the EI/CI Source PCB. 9. Remove the retainer clip that secures the filament and centering ring to the ion source block. 10. Remove the filament and centering ring from the ion source block. 11. Clean the ion source block and lenses. See “Cleaning Stainless Steel Parts” on page 113. Clean non-stainless steel parts as described in “Cleaning Non-Stainless Steel or Hybrid Part” on page 115. Y To reassemble the ion source 1. Reinstall the EI/CI Source PCB and filament. a. Align and insert the cartridge heaters and temperature sensor on the EI/CI Source PCB with the corresponding holes in the ion source block. IMPORTANT Ensure that the temperature sensor is seated snugly. b. Reinstall the three base studs. c. Align the filament leads with the EI/CI Source PCB connectors and gently press the leads into the connectors. Normally, there is a small gap (about 0.016 in.) between the filament and the connectors. The gap allows the ceramic centering ring to properly position and align the electron lens hole with the ion volume. 2. Press the heater ring and lens assemblies onto the ion source block. 3. Use the retainer clip and threaded standoff to secure the lens assembly to the ion source. See Figure 58. IMPORTANT For accurate temperature readings of the heater block, fully screw the threaded standoff into the ion source to ensure contact between the temperature sensor with the heater block. 4. Reinstall the ion source into the vacuum manifold. See “Reinstalling the TSQ Quantum XLS Ion Source” on page 94. 5. Restart the system. See “Starting Up the System after a Complete Shutdown” on page 51. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 109 6 Maintenance Disassembling and Reassembling the TSQ Quantum GC Ion Source Completely Disassembling and Reassembling the TSQ Quantum GC Ion Source Completely Disassemble the ion source completely to clean the ion source block or replace the EI/CI Source PCB. See Figure 58 for the location of the ion source components. Tools Needed • Gloves, cleanroom grade (P/N 23827-0008 and 23827-0009) • Lint-free cloth Frequency As needed Y To disassemble the ion source completely 1. Prepare a clean work area by covering the area with lint-free cloth. 2. Shut down and vent the TSQ Quantum XLS. See“Shutting Down the System Completely” on page 49. CAUTION Shock Hazard. Unplug the TSQ Quantum XLS before proceeding. 3. Wearing clean, lint- and powder- free gloves, remove the ion source. See “Removing the TSQ Quantum XLS Ion Source” on page 89. 4. Remove the ion source from the magnet yoke. 110 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Disassembling and Reassembling the TSQ Quantum GC Ion Source Completely Figure 59. Disassembling the ion source Filament retainer clip Filament Heater ring Centering ring Ion source block Lens assembly Threaded standoff Heater ring and lens assembly retainer clip EI/CI Source PCB Base studs 5. Pull the lens assembly off the ion source. 6. Pull the heater ring off the ion source. 7. Unscrew and remove the three base studs. CAUTION Shock Hazard. Do not pull the EI/CI Source PCB out of the ion source block. This might damage the EI/CI Source PCB. 8. Remove the EI/CI Source PCB. a. Place the ion source on a clean surface with the cartridge heaters down and the EI/CI Source PCB up. b. Press down on the ion source block to separate it from the EI/CI Source PCB. 9. Remove the retainer clip that secures the filament and centering ring to the ion source block. 10. Remove the filament and centering ring from the ion source block. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 111 6 Maintenance Disassembling and Reassembling the TSQ Quantum GC Ion Source Completely 11. Clean the ion source block and lenses. See “Cleaning Stainless Steel Parts” on page 113. Clean non-stainless steel parts as described in “Cleaning Non-Stainless Steel or Hybrid Part” on page 115. Y To reassemble the ion source 1. Reinstall the EI/CI Source PCB and filament. a. Align and insert the cartridge heaters and temperature sensor on the EI/CI Source PCB with the corresponding holes in the ion source block. IMPORTANT Ensure that the temperature sensor is seated snugly. b. Reinstall the three base studs. c. Align the filament leads with the EI/CI Source PCB connectors and gently press the leads into the connectors. Normally, there is a small gap (about 0.016 in.) between the filament and the connectors. The gap allows the ceramic centering ring to properly position and align the electron lens hole with the ion volume. 2. Press the heater ring and lens assembly onto the ion source block. 3. Use the retainer clip and threaded standoff to secure the lens assembly to the ion source. See Figure 58. IMPORTANT For accurate temperature readings of the heater block, fully screw the threaded standoff into the ion source to ensure contact between the temperature sensor with the heater block. 4. Reinstall the ion source into the vacuum manifold. See “Reinstalling the TSQ Quantum XLS Ion Source” on page 94. 5. Restart the system. See “Starting Up the System after a Complete Shutdown” on page 51. 112 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Disassembling and Reassembling the TSQ Quantum GC Ion Source Completely Cleaning Stainless Steel Parts Tools Needed • Acetone, reagent grade (or other suitable polar solvent) • Aluminum oxide abrasive, number 600 (P/N 32000-60340) • Applicators, cotton-tipped (P/N 00301-01-00015) • Beaker, 450 mL • Clean, dry gas • De-ionized water • Detergent (Alconox, Micro, or equivalent) • Dremel rotary tool or equivalent (recommended) • Foil, aluminum • Forceps (P/N 76360-0400) • Gloves, cleanroom grade (P/N 23827-0008 and 23827-0009) • Glycerol, reagent grade • Lint-free cloth • Protective eyewear • Tap water • Toothbrush, soft • Ultrasonic cleaner Frequency As needed to clean these stainless steel parts: • Ion volumes • Ion source block • Ion source lenses CAUTION Material and Eye Hazard. Wear impermeable laboratory gloves and eye protection when performing cleaning procedures. Y To clean stainless-steel parts 1. Remove contamination from all the surfaces you are cleaning. a. Use a slurry of number 600 aluminum oxide in glycerol and a cleaning brush or cotton-tipped applicator. Contamination appears as dark or discolored areas, but often is not visible. The heaviest contamination is usually found around the apertures, such as the electron entrance hole on an ion volume. b. Clean each part thoroughly, even if no contamination is visible. c. To clean the inside corners, use the wooden end of an applicator cut at an angle. d. Use a Dremel® tool with the polishing swab at its lowest speed to increase cleaning efficiency, as well as decrease the time required to clean the items. To prevent personal injury, be sure to keep the Dremel tool away from possible hazards, such as standing water or flammable solvents. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 113 6 Maintenance Disassembling and Reassembling the TSQ Quantum GC Ion Source Completely 2. Rinse the parts with clean water. Use a clean applicator or toothbrush to remove the aluminum oxide slurry. Do not let the slurry dry on the metal; dried aluminum oxide is difficult to remove. 3. Sonicate the parts in a warm detergent solution. a. Using forceps, place the parts in a beaker containing warm detergent solution. b. Place the beaker and contents in an ultrasonic bath for five minutes. c. Rinse the parts with tap water to remove the detergent. 4. Sonicate the parts in deionized water. a. Using forceps, place the parts in a beaker containing deionized water. b. Place the beaker and contents in an ultrasonic bath for five minutes. c. If the water is cloudy after sonicating, pour off the water, add fresh water, and place the beaker and its contents in an ultrasonic bath again for five minutes. Repeat until the water is clear. 5. Sonicate the parts in acetone. a. Using forceps, place the parts in a beaker containing acetone. b. Using forceps, transfer the parts to a beaker containing fresh acetone. c. Place the beaker and contents in an ultrasonic bath again for five minutes. 6. Blow-dry the parts immediately. Use clean, dry gas to blow the acetone off the parts. 7. Using forceps, place the parts in a beaker, cover the beaker with aluminum foil, and put the beaker in the oven. 8. Dry the parts in an oven set at 100 oC for 30 minutes. 9. Allow the parts to cool before putting them back together. 114 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Disassembling and Reassembling the TSQ Quantum GC Ion Source Completely Cleaning Non-Stainless Steel or Hybrid Part Tools Needed • Acetone, reagent grade (or other suitable polar solvent) • Aluminum oxide abrasive, number 600 (P/N 32000-60340) • Applicators, cotton-tipped (P/N 00301-01-00015) • Beaker, 450 mL • Clean, dry gas • De-ionized water • Detergent (Alconox, Micro, or equivalent) • Dremel rotary tool or equivalent (recommended) • Forceps (P/N 76360-0400) • Gloves, cleanroom grade (P/N 23827-0008 and 23827-0009) • Glycerol, reagent grade • Lint-free cloth • Protective eyewear • Tap water • Toothbrush, soft Frequency As needed to clean non-stainless steel parts (such as aluminum, ceramic, or gold-plated), or to clean hybrid parts that are partially made of stainless steel: • Lens holder and spacers • Filament spacer • Heater ring CAUTION Material and Eye Hazard. Wear impermeable laboratory gloves and eye protection when performing cleaning procedures. Y To clean non-stainless steel or hybrid parts 1. Remove contamination from stainless steel surfaces. It is only necessary to clean a surface that comes in contact with the ion beam. a. Use a slurry of number 600 aluminum oxide in glycerol and a cleaning brush or cotton-tipped applicator. Contamination appears as dark or discolored areas, but often is not visible. b. Clean each part thoroughly, even if no contamination is visible. c. To clean the inside corners, use the wooden end of an applicator cut at an angle. d. Use a Dremel tool with the polishing swab at its lowest speed to increase cleaning efficiency, as well as decrease the time required to clean the items. To prevent personal injury, be sure to keep the tool away from possible hazards, such as standing water or flammable solvents. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 115 6 Maintenance Maintaining the Forepump 2. Rinse the parts with clean water. Use a clean applicator or toothbrush to remove the aluminum oxide slurry. Do not let the slurry dry on the metal; dried aluminum oxide is difficult to remove. 3. Scrub all of the parts with a warm detergent solution. a. Scrub the parts with a toothbrush or clean applicator. Do not soak or sonicate the parts in detergent. b. Using forceps, rinse the parts thoroughly with tap water to remove the detergent. CAUTION Do not leave aluminum parts, such as the heater ring, in the detergent. Basic solutions, like detergent, discolor aluminum. 4. Rinse the parts in deionized water. Using forceps, dip the parts in a beaker of deionized water. Change the water if it becomes cloudy. Do not soak or sonicate the parts. 5. Rinse the parts with acetone. Using forceps, dip the parts in a beaker of acetone. Change the acetone if it becomes cloudy. Do not soak or sonicate the parts. 6. Blow-dry the parts immediately. Use clean, dry gas to blow the acetone off the parts. Maintaining the Forepump Inspecting, adding, purging, and changing the forepump oil are all that is required to maintain the forepump. Forepump oil is a translucent, light amber color, which you must check often. During normal operation, oil must always be visible in the oil level sight glass between the MIN and MAX marks. If the oil level is below the MIN mark, add oil. If the oil is cloudy or discolored, purge the oil to decontaminate dissolved solvents. If the pump oil is still discolored, change it. You should change the pump oil every 3000 hours (about four months) of operation. Refer to the manufacturer’s documentation for procedures for purging, adding, and changing the forepump oil. CAUTION If you use ammonia as a chemical ionization reagent gas, change the oil every month. Ammonia is highly basic and quickly damages seals in the forepump. Purging the oil with the Gas Ballast Control helps remove dissolved ammonia from the oil. 116 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Adding Calibration Compound Adding Calibration Compound Tools Needed • Calibration compound (P/N 50010-02500) • Syringe (P/N 36502019) • 9/16 in., open-ended wrench Frequency Yearly or as needed The calibration compound is a liquid whose mass spectrum of ions is used to tune and calibrate the TSQ Quantum XLS and TSQ Quantum GC mass spectrometers. The mass spectrometer uses FC-43 as its calibration compound. Although you cannot visually determine when a calibration compound needs to be added, Xcalibur Automatic Tune produces an error message indicating that “the intensity of calibration gas ions is too low.” This message indicates that calibration compound must be added. However, there are many factors other than a decrease in the calibration compound that can cause a shortage of calibration gas ions. As a rule, add calibration compound once a year. Y To add calibration compound 1. Shut down and vent the mass spectrometer. See “Shutting Down the System Completely” on page 53. 2. Lower the GC oven and transfer line temperatures to 30 °C and allow them to cool before continuing. CAUTION The transfer line is hot. Allow it to cool to room temperature before moving the GC. 3. Move the GC far enough from the mass spectrometer to access the calibration compound vial compartment. See the location of the calibration compound vial compartment in Figure 60. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 117 6 Maintenance Adding Calibration Compound Figure 60. Location of the calibration compound vial compartment Calibration compound vial compartment 4. Remove the cover to the calibration compound vial compartment. 5. Remove the calibration compound vial from the calibration gas flow module. See Figure 61. a. Use a 9/16 in. wrench to remove the nut from the calibration compound vial. b. Slide the vial away from the calibration valve fitting with the ferrule and nut attached. c. Remove the ferrule and nut. CAUTION Having more than 0.1 mL of the calibration compound can damage the calibration gas flow module. Be sure that there is less than 0.1 mL of the calibration compound in the vial. 6. Add the calibration compound. a. Draw up no more than 0.1 mL of calibration compound into a clean syringe. b. Insert the syringe in the calibration compound vial until it comes in contact with the white frit at the bottom of the vial. c. Inject no more than 0.1 mL of calibration compound into the white frit. The frit absorbs the calibration compound, so if the calibration compound is pooled (calibrant covers the top of the frit), then you have too much in the vial. Immediately pour out the excess calibrant according to local environmental regulations. 118 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Adding Calibration Compound 7. Remove the syringe from the calibration compound vial. Figure 61. Calibration compound vial Ferrule Nut Calibration compound vial 8. Inspect the 1/4 in. ferrule for damage. Replace it if necessary (P/N 95001-20310). 9. Reinstall the calibration compound vial (P/N 96000-40013) into the module. a. Hold the vial vertically and place the nut on the neck of the vial. b. Place the 1/4 in. ferrule over the neck of the vial and into the nut. c. Connect the vial to the calibration valve fitting with the nut and ferrule. 10. Reinstall the cover to the calibration compound vial compartment. 11. Position the GC next to the mass spectrometer. 12. Restart your system. See “Starting Up the System after a Complete Shutdown” on page 55. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 119 6 Maintenance Replacing the Ball Valve Seal Replacing the Ball Valve Seal Tools Needed • Ball valve seal kit (P/N 119265-0003) Frequency If the ball valve seal leaks air after you insert the direct insertion probe or I/R tool into the inlet valve and tighten the inlet valve knob The ball valve seal in the inlet valve can become worn over time. Replace the ball valve seal if it leaks air after you insert the direct insertion probe or I/R tool and tighten the inlet valve knob. The ball valve seal kit (P/N 119265-0003) is included in the TSQ Quantum XLS Accessory Kit. The ball valve seal consists of a Teflon® spool and two O-rings. See Figure 62. Figure 62. Components of the ball valve seal and inlet valve Inlet valve housing Ball valve seal components Inlet valve insert Inlet valve knob You use the ball valve seal extraction tool (part of the ball valve seal kit, P/N 119265-0003) to remove the ball valve seal. See Figure 63. 120 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Replacing the Ball Valve Seal Y To remove the ball valve seal 1. Loosen the inlet valve knob counter-clockwise until you can remove it. 2. Remove the inlet valve knob, plug, and insert. 3. Insert the not-engaged ball valve seal extraction tool into the inlet valve housing. 4. Engage the ball valve seal by pushing the plunger of the ball valve seal extraction tool forward. 5. Remove the seal and tool. 6. Pull the plunger back to disengage the seal. Figure 63. Ball valve seal extraction tool and ball valve seal, not engaged (left) and engaged (right) Y To install the ball valve seal 1. Obtain the ball valve seal kit (P/N 119265-0003) from the Accessory Kit. 2. Assemble the ball valve seal by installing the two O-rings onto the Teflon™ spool. 3. Insert the ball valve seal into the ball valve manifold with your finger. 4. Install the inlet valve knob and insert. 5. Install the inlet valve plug and tighten the inlet valve knob clockwise. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 121 6 Maintenance Removing and Installing a GC Capillary Column Removing and Installing a GC Capillary Column You replace the GC capillary column if the chromatographic separation is bad or if it does not have the appropriate stationary phase for your application. Tools Needed • Gloves, cleanroom grade (P/N 23827-0008 and 23827-0009) • Wrench, open-ended, 5/16 in. • Wrench, open-ended, 7/16 in. • Wrench, open-ended, 6 mm Frequency As needed for maintenance or column replacement Removing a GC Capillary Column Y To remove a GC capillary column 1. Shut down the TSQ Quantum XLS or TSQ Quantum GC and the gas chromatograph. a. Shut down and vent the mass spectrometer. See “Shutting Down the System Completely” on page 53. b. Lower the oven, injector, and transfer line temperatures to 30 °C and allow them to cool before continuing. CAUTION The oven, injector, and transfer line are hot. Allow them to cool to room temperature before touching them. c. Once the oven, injector, and transfer line are cool, turn off the gas chromatograph. 2. Remove the column from the transfer line. See Figure 64. a. Unscrew the transfer line nut. b. Remove the column from the transfer line. 122 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Removing and Installing a GC Capillary Column Figure 64. GC injector and transfer line unions 3. Remove the column from the injector. Refer to the Column chapter of the TRACE GC Ultra Operating Manual for instructions. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 123 6 Maintenance Removing and Installing a GC Capillary Column Installing a GC Capillary Column Tools Needed • Capillary column • Gloves, cleanroom grade (P/N 23827-0008 and 23827-0009) • Injector ferrule, for 0.25 mm column (P/N 290 134 88) • Leak detector, hand-held electronic (GL Sciences, Inc., model LD-228, or equivalent) • Lint-free tissue • Magnifying glass • Methanol or other suitable solvent • Scoring wafer (or sapphire scribe) to cut capillary column • Transfer line ferrule, 0.4 mm ID (P/N A0101-18100) • Wrench, open-ended, 5/16 in. • Wrench, two, open-ended, 7/16 in. • Wrench, open-ended, 6 mm Frequency As needed Refer to the TRACE GC Ultra Operating Manual and the TRACE GC Ultra Maintenance and Troubleshooting Manual for additional GC column installation information. Y To install a GC capillary column CAUTION Burn Hazard. The injector, oven, and transfer line might be hot. Allow them to cool to room temperature before touching them. Note Wear clean, lint- and powder-free gloves when you handle the column and injector ferrule. 1. Connect the column to the injector. Refer to the Column chapter of the TRACE GC Ultra Operating Manual for instructions. Refer to the TRACE GC Ultra Quick Reference card for the column depth length for your injector. 2. Set up the gas chromatograph. a. Turn on the gas chromatograph. b. Set the oven and injector temperatures to 30 °C. c. Set the injector flow to 1.0 mL/min. d. Turn off vacuum compensation (under the Right or Left Carrier menu). 124 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Removing and Installing a GC Capillary Column e. Dip the column outlet in a small vial of methanol. Bubbles indicate there is flow through the column. f. Allow the column to purge for at least 10 minutes. 3. Perform a manual column leak check. Refer to the Ensuring Tightness chapter of the TRACE GC Ultra Maintenance and Troubleshooting Manual for instructions. 4. Perform a column evaluation. Refer to the Column chapter of the TRACE GC Ultra Operating Manual for instructions. Refer to the K-Factor Quick Reference card for expected K factors for various column diameters, column lengths, and carrier gases. Note The K factor is a measure of the resistance of the column. A K factor that is too low might indicate a leak in the system, while a K factor that is too high might indicate a blockage. 5. Perform an automatic column leak check. a. Run an automatic leak check. Refer to the Column chapter of the TRACE GC Ultra Operating Manual for instructions. b. If the report indicates a leak, look for leaks and use the leak detector to fix leaks at all the fittings in the GC. c. Repeat column evaluation and leak check procedures until no leaks can be found. CAUTION Do not raise the oven temperature until you are sure the system is leak-free. At temperatures above 100 °C, oxygen exposure will destroy the column. 6. Condition the capillary column according to the manufacturer’s instructions. New columns must be conditioned before inserting them in the mass spectrometer. CAUTION Do not insert the column into the transfer line during the co. The material released from the column during the conditioning (column bleed) will contaminate the ion source. You must then clean the ion source. CAUTION Never exceed the column manufacturer’s maximum operating temperature. 7. Connect the column to the transfer line. a. Shut down and vent the mass spectrometer. See“Shutting Down the System Completely” on page 53. b. Lower the GC oven temperature to 30 °C and allow it to cool before continuing. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 125 6 Maintenance Removing and Installing a GC Capillary Column CAUTION Burn Hazard. The GC oven and transfer line might be hot. Allow them to cool to room temperature before touching them. Do not touch the injector when it is hot. c. Wearing clean, lint- and powder-free gloves, unwind about one turn of the capillary column (shown in Figure 64) from the column outlet end. d. Wipe about 450 mm (18 in.) of the column with a tissue soaked in methanol. Note Sliding a septum on the column before the transfer line nut helps you measure the proper distance between the nut and the end of the column. The column should extend approximately 1 to 2 mm past the end of the transfer line. e. Insert the column through the transfer line nut and ferrule. Wipe the column again with a tissue soaked in methanol. f. Score and break the end of the column with a scoring wafer. With the magnifying glass, check for an even, flat cut. Repeat if necessary. g. Insert the column into the transfer line. i. Open the lid of the ion source vacuum chamber so that you can get a better view of the column. ii. Using the I/R tool, remove the ion volume. See “Removing the Ion Volume” on page 73. iii. Insert the column into the transfer line and tighten the transfer line nut by hand. iv. Push the column in until you can see it through the inlet valve. v. Pull the column back just far enough that you cannot see it. vi. Tighten the transfer line nut and transfer line union. vii. Using the I/R tool, replace the ion volume. See “Installing the Ion Volume” on page 80. 8. Condition the transfer line ferrule. Graphite/Vespel™ ferrules like the transfer line ferrule require conditioning to ensure a leak-tight seal. a. Raise the oven temperature to the maximum temperature at which you will operate the column (normally 300 °C). b. Wait 10 minutes. c. Lower the oven temperature to 30 °C and allow it to cool before continuing. CAUTION The oven might be hot. Allow it to cool to room temperature before opening it. Do not touch the injector, which will still be hot. d. Re-tighten the transfer line nut and the transfer line union. 126 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 6 Maintenance Removing and Installing a GC Capillary Column 9. Set up the gas chromatograph. a. Make sure the column does not have any sharp bends and that it does not touch any metal objects or walls inside the oven. b. Raise the oven temperature to the initial temperature that you will use (normally 40 °C). c. Turn on the vacuum compensation (under the Right or Left Carrier menu). Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 127 7 Diagnostics and Troubleshooting The TSQ Quantum XLS and TSQ Quantum GC system diagnostics can test many components of the TSQ Quantum XLS and TSQ Quantum GC mass spectrometers. If there is a problem with the instrument electronics, the diagnostics can often locate the problem. Replacing a faulty PCB or assembly can usually correct the problem. After the PCB or assembly is replaced, the diagnostic tests are rerun to verify the instrument is functioning properly. Contents • TSQ Quantum XLS and TSQ Quantum GC System Diagnostics • Troubleshooting • Replacing a Fuse • Replacing PCBs and Power Supplies TSQ Quantum XLS and TSQ Quantum GC System Diagnostics The TSQ Quantum XLS and TSQ Quantum GC system diagnostics are used to test the major electronic circuits within the instrument and indicate whether the circuits pass or fail the tests. If there is a problem with the instrument electronics, the system diagnostics can often locate the problem. The system diagnostics do not diagnose problems that are not electrical in nature. For example, they do not diagnose poor sensitivity due to misaligned or dirty components or to improper tuning. Therefore, it is important that the person running the diagnostics be familiar with system operation and basic hardware theory as well as the details of the diagnostics. IMPORTANT Typically, only a Thermo Fisher Scientific Field Service Engineer runs diagnostic tests because certain tests can overwrite system parameters. Before calling a Thermo Fisher Scientific Field Service Engineer to run diagnostics, consider the following: • Did the system fail when you were running samples? Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 129 7 Diagnostics and Troubleshooting TSQ Quantum XLS and TSQ Quantum GC System Diagnostics • Did problems occur after you performed maintenance on the instrument, data system, or peripherals? • Did you change the configuration of the system, cables, or peripherals just before the problem occurred? If the answer is yes to the first item above, there is the possibility of a hardware failure, and running the diagnostics is appropriate. If the answer is yes to either of the last two questions above, the problem is probably mechanical, not electrical. Reverify that alignment, configurations, and cable connections are correct before you call the Thermo Fisher Scientific Field Service Engineer. Keep careful notes documenting the nature of the problem and the corrective steps you have taken. If you are not successful in correcting the problem, you can e-mail this information to Field Service engineer. Field Service can then do a preliminary evaluation of the problem before the Field Service engineer arrives at your site. 130 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 7 Diagnostics and Troubleshooting Troubleshooting Troubleshooting The following topics discuss possible TSQ Quantum XLS and TSQ Quantum GC system problems and solutions. Communication Issues Communication issues likely involve links between the data system and the mass spectrometer, gas chromatograph, or autosampler. This section does not address communication issues with other devices. Communication issues can occur during the following: • Data transfer between the mass spectrometer and the data system • Mass spectrometer, gas chromatograph, and autosampler current status readbacks • Instrument control, method downloading, and uploading • Start, stop, pause, and initialize functions • Error messages How does the MS communication work? The flow of digital information in the TSQ Quantum XLS and TSQ Quantum GC systems is bi-directional; the data system downloads analytical methods to the instrument and activates functions to start, stop, shut down, start up, and initialize. The TSQ Quantum XLS and TSQ Quantum GC systems report their readiness state, current tasks, various voltages, heated zones, and pressure readings. It also delivers a steady stream of mass spectral data during acquisition. Why does the MS have communication issues? Some communication issues are due to mechanical faults—for instance, a cable might be unplugged, or a device might be turned off. In other cases, the instrument method could be incorrect for TSQ Quantum XLS or TSQ Quantum GC system operations. Less common communication issues are due to defective electronic hardware components. How do I detect communication issues? You might detect communication issues from an error message delivered by the data system, or you might notice the failure of the data system to perform some expected task. Issue: Data system is unable to initiate communication with the mass spectrometer. Thermo Scientific Possible causes/solutions • The software is not configured correctly. Select and configure the mass spectrometer from the Instrument Configuration window. TSQ Quantum XLS and TSQ Quantum GC User Guide 131 7 Diagnostics and Troubleshooting Troubleshooting • The Ethernet cable is unplugged. Verify that the Ethernet cable is connected to the Ethernet port on the mass spectrometer. See Figure 12 on page page 25. • The Ethernet card in the PC is not configured or is faulty. Check the configuration or replace the Ethernet card if necessary. • The mass spectrometer is in Service Mode. Return the electronics service switch to operating position. • An incorrect Ethernet cable is used for the mass spectrometer. Use the supplied 10 Base-T Category 5 crossover cable (P/N 76396-0052, in TSQ Quantum XLS Accessory Kit). Note You can extend the length of the Ethernet cable by plugging a standard Category 5 cable in series with the supplied crossover cable. Issue: Computer intermittently loses communication with the mass spectrometer. Possible cause/solution Issue: Unable to download methods to the mass spectrometer. Possible cause/solution Issue: Acquisition does not begin as expected. • The Ethernet cable is loose or damaged. Inspect the cable and replace it if necessary. • The software is not properly configured. Verify the correct settings in Instrument Configuration. Possible causes/solutions • The TSQ Quantum XLS or TSQ Quantum GC start mode is not properly configured. Verify that the instrument is configured properly. Refer to Xcalibur Help for more information. • The TSQ Quantum XLS or TSQ Quantum GC Instrument Setup file has incorrect settings. Check the start time in the Instrument Setup file. • The forepressure is too high due to solvent peak. Reduce injection volume or extend filament/multiplier delay time until after solvent peak. • The remote start cable to the GC is disconnected. Connect the remote start cable. • The GC did not start. Verify GC instrument method and configuration. Verify the connection between the autosampler and GC. • The autosampler did not start. Verify autosampler instrument method and configuration. Verify that the sample is present. • The heated zone stipend is not attained. See “Heated Zone Issues” on page 136. 132 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 7 Issue: Acquisition terminates unexpectedly. Diagnostics and Troubleshooting Troubleshooting Possible causes/solutions • The end run time in the TSQ Quantum XLS or TSQ Quantum GC instrument method is incorrect. Check the instrument method for the GC and the MS. • The data system is out of disk space. Check disk space; back up and remove files. Issue: Unable to initialize the gas chromatograph. Possible causes/solutions • The GC is not turned on. Turn on the GC. • The GC is not configured properly in Xcalibur. Check Instrument Configuration. • The cable between COM1 and GC is disconnected. Verify connection. • COM1 is not configured properly. Verify COM port configuration. Issue: Unable to download methods to the gas chromatograph. Possible causes/solutions • There is a discrepancy between the instrument method and configuration. Verify consistency between method and instrument configuration. • COM1 is not configured properly. Verify COM port configuration. Issue: Unable to initialize the autosampler. Possible causes/solutions • The autosampler is not turned on. Turn on autosampler. • The autosampler is not configured properly in Xcalibur. Check Instrument Configuration. • The cable between the GC and autosampler is disconnected. Verify connection. • The autosampler instrument configuration is not set to the correct port. Verify connection and configuration. Issue: Unable to download methods to the autosampler. Possible cause/solution • There is a discrepancy between instrument method and configuration. Verify consistency between instrument method and instrument configuration. Contamination Issues Chemical noise is always present in any mass spectrometer. As a result, the high sensitivity of the mass spectrometer can cause new users to confuse background with a contamination problem. Additionally, the spectra shown in Xcalibur Tune and Real-Time Display are auto-normalized, which can make the background appear high-level. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 133 7 Diagnostics and Troubleshooting Troubleshooting Some chemical noise does occur, such as septum bleed after a series of injections, vial sample bleed (which occurs if more than one injection is made from a sample vial), and siloxane peaks that appear in the chromatogram at regular intervals from focusing at the head of the column or in the injector. Other possible contamination sources include hydrocarbon contamination of the carrier gas, pump oil, or instrument cleaning solvents. Always wear clean, lint- and powder- free gloves when handling ion source and mass analyzer components, and ensure that the carrier gas filter, carrier gas lines, and gas regulators are free of contamination and leaks. Issue: Excessive chemical background due to a column bleed (m/z 429, 355, 281). Possible causes/solutions • The capillary column has not been properly conditioned. Condition the capillary column. • The capillary column is damaged as a result of exposure to oxygen. Find the source of the oxygen in the carrier gas or air leak. Recondition or replace the capillary column. Issue: Excessive injection port septum bleed (Typical m/z 207, 429, 355, 281). Possible causes/solutions Issue: Phthalate background (m/z 149, 167, 279). Possible causes/solutions • The septum is worn out or damaged. Replace the septum. • Small pieces of septum are in the injection port liner. Replace the injection port liner; condition the capillary column. • Phthalate contamination has occurred due to sample handling or solvent contamination. • Packaging materials could be the source of phthalates. • Isolate source of phthalates such as vial lids or plastic solvent containers and remedy. Issue: Excessive hydrocarbon contamination (Typical ions are m/z 43, 57, 71, 85, 99). Possible causes/solutions • Carrier gas tubing is contaminated. • Isolate source of hydrocarbon contamination and remedy. • Replace carrier gas tubing. • Change carrier gas filters. 134 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 7 Issue: Chemical background due to rhenium oxide (m/z 185/187, 201/203, 217/219, 233/235, 250/252). Issue: Spectra are observed due to the following solvents: Diagnostics and Troubleshooting Troubleshooting Possible causes/solutions • These series of rhenium oxide ions come from oxidation of the rhenium filament wire due to the introduction of air into the ion source while the filament is on. • Check for air leaks and remedy. See “High Vacuum Issues” on page 138 for more information. Solvent Spectra Acetone (m/z 43, 58, 59) Hexane (m/z 41, 43, 56, 57, 58, 85, 86) Methanol (m/z 31) Methylene chloride (m/z 84, 83) Toluene (m/z 91, 92) Trichloroethane (m/z 151, 153) Xylene (m/z 105, 106) Possible causes/solutions • There is residual solvent from a cleaning procedure or laboratory background contamination. When you finish performing a cleaning procedure, allow cleaned components to dry thoroughly. Warm parts in the GC oven to drive off residual solvent. • The observed compounds have been introduced through sample injection. The ultimate source is either a sample solvent or the autosampler rinsing solvent. Optimize GC method to separate solvent peak from the area of interest in the chromatogram. Filament and Lens Control Issues The lifetime of a filament depends on its exposure to oxygen and solvent vapors. The filament assembly protects the filament and increases its lifetime for many months. Xcalibur diagnostics test the filament for continuity and current regulation. Testing the filament for continuity before each acquisition ensures that an open filament condition will stop an autosampler sequence and generate an error message. Diagnostics test the lenses of the TSQ Quantum XLS and TSQ Quantum GC mass spectrometers. A flat line, which represents voltage readback versus the predicted voltage ramp, indicates a lens or other control fault. Contamination causes lens performance to deteriorate over time; the amount of time depends on what type of sample and ionization mode you use. Be careful to handle the lenses with care, and do not use harsh cleaning techniques. Damaged lenses cause short circuits, which in turn can cause damage to the lens drivers. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 135 7 Diagnostics and Troubleshooting Troubleshooting Issue: Diagnostics indicate that the filament is open. Possible cause/solution Issue: Unstable emission current. Possible cause/solution Issue: Short filament lifetime. • The filament is open. Vent the system and remove the filament. Normal resistance is 1.0 Ω. Replace if open. • The filament is near the end of its life span. Replace the filament. Possible causes/solutions • There is an air leak contributing to short filament lifetime. Check for leaks; repair if any are found. See “High Vacuum Issues” on page 138 for more information. • The filament is on during the solvent peak. Increase acquisition delay time until the solvent peak has passed. • High emission current is being used. Use lower emission current to extend lifetime. Issue: Diagnostics indicate a flat lens response. Possible causes/solutions • The power supply to the lens has a fault. Contact Thermo Fisher Scientific Technical Support. • There is a fault with the lens drivers. Contact Thermo Fisher Scientific Technical Support. Heated Zone Issues The ion source and transfer line are heated zones. The ion source heater is controlled by the mass spectrometer and the transfer line heater is controlled by the Aux1 heated zone of the TRACE GC. A heated zone problem is often the result of downloading an instrument method to the instrument that has a different setpoint than the current setting, causing a delay while the heated zone heats or cools. Component failures are less common but can occur. These are usually related to open circuits in heater cartridges or faulty temperature sensors. This manual does not discuss heated zones in the gas chromatograph. Issue: Excessive chromatographic peak tailing. 136 Possible causes/solutions • The ion source, transfer line, or both are not hot enough. Increase the transfer line temperature. It should be at least as hot as the highest GC oven temperature. Then, try increasing the ion source temperature. TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 7 Diagnostics and Troubleshooting Troubleshooting • The sample analyte is adsorbing in the GC injector. Clean and deactivate the injection liner. You can also try liners made of different materials. • The GC oven is not ramped to a high enough temperature. Extend upper oven temperature. • The GC column must be replaced or does not have the appropriate stationary phase for your application. Change the GC column. See “Removing and Installing a GC Capillary Column” on page 122. • The GC column does not extend far enough past the end of the transfer line tip. If the end of the column is inside the tip, an excessive amount of GC effluent will contact the inside wall of the tip. Follow the procedure described in “Installing a GC Capillary Column” on page 124. Issue: Source heater will not heat. Possible causes/solutions • No contact between the ion source temperature sensor and the heater block. For accurate temperature readings of the heater block, fully screw the threaded standoff into the ion source to ensure contact between the temperature sensor and the heater block. See “Reassembling the L1, L2, L3 Lens Assembly” on page 93. • One or more heater cartridges on the EI/CI Source PCB is defective. Replace the EI/CI Source PCB. See “Disassembling and Reassembling the TSQ Quantum XLS Ion Source Completely” on page 107 (TSQ Quantum XLS), or “Disassembling and Reassembling the TSQ Quantum GC Ion Source Completely” on page 110 (TSQ Quantum GC). • The ion source temperature sensor (RTD) is defective. Replace the EI/CI Source PCB. See “Disassembling and Reassembling the TSQ Quantum XLS Ion Source Completely” on page 107 (TSQ Quantum XLS), or “Disassembling and Reassembling the TSQ Quantum GC Ion Source Completely” on page 110 (TSQ Quantum GC). Issue: Source heater overheats. Possible cause/solution Issue: Transfer line will not heat. Possible causes/solutions • The ion source temperature sensor (RTD) is defective. Replace the EI/CI Source PCB if necessary. See “Disassembling and Reassembling the TSQ Quantum XLS Ion Source Completely” on page 107 (TSQ Quantum XLS), or “Disassembling and Reassembling the TSQ Quantum GC Ion Source Completely” on page 110 (TSQ Quantum GC). • Aux1 zone of the GC is not configured for MS Transfer Line. Configure Aux1 zone of the GC and set transfer line temperature in the GC Method Editor. • Transfer line heater elements are defective. Replace the transfer line. • The transfer line temperature sensor (RTD) is defective. Replace the transfer line. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 137 7 Diagnostics and Troubleshooting Troubleshooting Issue: Transfer line overheats. Possible cause/solution • The transfer line temperature sensor is defective. Replace the transfer line. High Vacuum Issues High vacuum problems can manifest themselves in two ways: • An intermittent vacuum condition (the vacuum pressure in the vacuum manifold fluctuates intermittently) can cause chromatographic signals to drop out, or, if the pressures exceed the maximum allowed pressures set in Xcalibur (See Table 3 on page 57), then the TSQ Quantum XLS or TSQ Quantum GC turns off. • If the vacuum is consistent enough that it does not exceed the maximum allowed pressure and avoids the Xcalibur automatic shutdown, non-reproducible false chromatographic peaks can be generated in the chromatogram. Typical forepressure readbacks are 30 to 40 mTorr (in EI mode), and typical manifold pressure (ion gauge readback) is 2 × 10-5 Torr with argon collision gas on, and 2 × 10-6 Torr with Ar collision gas off. The most reliable way to find vacuum leaks is to spray a gas around the vacuum manifold and look for the characteristics ions in full-scan EI mode. Argon produces m/z 40. Alternatively, you can use compressed electronic dusting spray containing an HFC. For example, Falcon® Dust-Off®and MicroCare® Micro-Blast™ contain tetrafluoroethane, which produces ions at m/z 69 and 83. Issue: Forepump will not turn on. Possible causes/solutions • The forepump is off. Check the forepump switch. • The vacuum service switch is in the Off position. Place the vacuum service switch in the operating position. • The forepump power cable from the TSQ Quantum XLS or TSQ Quantum GC is not connected. Connect the power cable. • The forepump is faulty. Replace the forepump. Issue: Forepump powers on, but will not pump down. Possible causes/solutions • The oil level in the forepump is insufficient. Check oil level; add oil if necessary. • The foreline is leaking. Check the clamps and connectors. Replace the foreline hose if a hole is found. • The vacuum manifold cover is leaking. • The forepump is faulty. Replace the forepump. 138 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 7 Issue: Turbo pump shuts off during operation. Issue: Unexpected full ventilation occurs. Diagnostics and Troubleshooting Troubleshooting Possible cause/solution • The foreline pressure is too high. Check for leaks in the foreline. Possible causes/solutions • A gross leak is present. Check for leaks. • The system was vented through the inlet valve. Close and plug the inlet valve. • The GC column broke at the transfer line. Replace the GC column. See “Removing and Installing a GC Capillary Column” on page 122. • The foreline was cut. Replace the foreline hose. Issue: Vacuum is faulty. Possible Solutions • A gross leak is present. Check for leaks. • The pressure in the analyzer region of the vacuum manifold, as measured by the ion gauge, must be below the pressures listed in Table 3 on page 57. Linearity Issues Linearity issues occur when a plot of intensity versus concentration of a known compound is not linear. Poor instrument operating conditions can cause linearity problems. Additionally, certain compounds do not give a desired linear response due to chromatographic activity. A well-maintained instrument provides good linear response over a wide range of concentrations for most compounds. Like any instrument, however, the TSQ Quantum XLS and TSQ Quantum GC has a saturation point. Perform routine injector and column maintenance to minimize linearity problems. Usually, a hardware fault that affects linearity shows different issues than those that might be attributed to linearity. Issue: Calibration plots not sufficiently linear. Possible causes/solutions • High-end standards are too concentrated for the MS. Use the split injection technique to decrease the amount of sample or lower emission current to reduce MS sensitivity. • The ion volume and lenses are dirty. Clean ion volume and lenses as described in “Cleaning Ion Source Components” on page 85. • The electron multiplier setting is incorrect. Run Auto Tune - Calibration as described in “Tuning and Calibrating” on page 63. • The injection port liner or capillary column is dirty. Change the injection port liner and trim the capillary column. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 139 7 Diagnostics and Troubleshooting Troubleshooting • The capillary column stationary phase is too thin for high concentration samples. Use a higher capacity capillary column with a thicker stationary phase, or use a split injection technique. • The capillary column is bad. Replace the capillary column. See “Removing and Installing a GC Capillary Column” on page 122. Power Supply Issues Xcalibur diagnostics detect most power supply issues. Power supply problems often involve a blown fuse, faulty electronic components, or something as simple as a disconnected cable. Fuses should be replaced by a Thermo Fisher Scientific Field Service Engineer. Issue: TSQ Quantum XLS will not power on. Possible causes/solutions • The power cord is disconnected. Verify that the power cord is plugged in. • Voltage is not coming from the electrical outlet. Verify that the electrical outlet is operational. • The Power Module is faulty. Contact Thermo Fisher Scientific Technical Support. Issue: The TSQ Quantum XLS powers on, but trips the circuit breaker. Possible causes/solutions • The Power Module is faulty. Contact Thermo Fisher Scientific Technical Support. • The forepump causes the circuit breaker to trip. Check forepump; replace it if necessary. Sensitivity Issues If you observe a drop in instrument sensitivity, you should determine if the sensitivity drop was sudden or if it occurred gradually. A sudden loss of sensitivity can be the result of sudden component failure or an unnoticed change in the analytical method. Simple errors such as a plugged autosampler syringe or too low sample level in the sample vial can give the appearance of instrument failure. Gradual drops in sensitivity are usually the result of ion volume or lens contamination, and are easily remedied by cleaning the ion volume or lenses. The electron multiplier influences sensitivity and has a limited lifetime. Eventually the electron multiplier must be replaced. Improper GC maintenance is another cause of diminished sensitivity. It is important to establish a routine maintenance program for the GC. See the TRACE GC Maintenance Manual for more information on establishing a maintenance program. 140 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 7 Issue: The chromatogram has a low total ion current signal. Diagnostics and Troubleshooting Troubleshooting Possible causes/solutions • The GC temperature ramp does not continue to a high enough temperature to elute high boiling point compounds. Multiple injections cause these compounds to accumulate in a column, reducing sensitivity. Extend upper temperature or the time at upper temperature in the GC oven ramp. • The instrument is out of tune, or the tune file is incorrect. Select correct tune file for the method or run automatic tune as described in “Tuning and Calibrating” on page 63. • The ion volume is contaminated. Clean the ion volume. • The ion volume is incorrectly positioned. Position the ion volume properly. • The magnets above and below the ion source are installed incorrectly. Position both magnets so the south pole is on top. Electrons will not focus into the ion volume if one magnet is upside down. • Dust has collected in the electron multiplier or on the conversion dynode. Contact Thermo Fisher Scientific Technical Support. • The emission current is set too low. Check the setting listed for the emission current. Choose Tune > Manual and select the Controls tab. • The ground connection between the electrometer PCB and anode feedthrough is faulty. Contact Thermo Fisher Scientific Technical Support. • There is a problem with the filament or lens control. See “Filament and Lens Control Issues” on page 135 for more information. • The EI/CI Source PCB is faulty, allowing emission current to leak to ground. Contact Thermo Fisher Scientific Technical Support. • Reagent gas is leaking into the analyzer, suppressing EI signal. Check for presence of CI reagent ions in spectrum. Replace CI Gas Flow Module if necessary. Issue: Poor compound sensitivity. Possible causes/solutions • The syringe, injection port liner, and column depth in injector are incorrectly matched. See TRACE GC Ultra Operators Manual for the correct combination. • Sample delivery is insufficient due to a plugged syringe needle. Clean or replace the syringe. • The injection port liner is contaminated. Clean or replace the injection port liner. • Graphite or septa particles contaminate the injection port. Clean the injection port. • The injector or septum is leaking. Replace septum and perform leak check on the GC. • The capillary column is at the end of its life span. Replace the capillary column. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 141 7 Diagnostics and Troubleshooting Troubleshooting • Method development problems are present. Contact Thermo Fisher Scientific Technical Support. Issue: Sensitivity is unstable or shows decrease with repeated injections. Possible causes/solutions • The GC temperature ramp does not continue to a high enough temperature to elute high boiling point compounds. Multiple injections cause these compounds to accumulate in a column, reducing sensitivity. Extend the upper temperature or the time at upper temperature in the GC oven ramp. • The ion volume or lenses are contaminated. Clean the ion volume and lenses as described in “Cleaning Ion Source Components” on page 85. • The ion source temperature is too low and causes the ion source to contaminate too quickly. Clean ion volume and lenses as described in “Cleaning Ion Source Components” on page 85 and then raise ion source temperature. • There is a problem with the filament emission current control. See “Filament and Lens Control Issues” on page 135 for more information. • The electron multiplier is faulty. Contact Thermo Fisher Scientific Technical Support. • The injection port liner or capillary column is contaminated. Replace the injection port liner and trim the capillary column. Issue: Poor sensitivity in CI mode. Possible causes/solutions • An EI ion volume is installed. Install a CI ion volume as described in “Changing Ionization Modes” on page 73. • The small hole in the CI ion volume is plugged. Use a dental pick or old syringe needle to clear it. • The filament is not aligned. Remove the ion volume and check if the ion burn is centered around the small electron entrance hole. Be sure the filament is properly inserted into the connector. Carefully bend the filament wire to better align it with the ion volume. • The ion volume is not inserted properly. While running the instrument, you can push on the ion volume with the I/R tool. Be sure to monitor the pressure to ensure that you get a good seal around the I/R tool. Otherwise, you may damage the filament. An increase in signal calibration gas as you push on the ion volume usually indicates that the filament is not aligned properly. Stability Issues Stability helps provide consistent instrument precision and the reproducibility of accurate results. Good operating conditions for the mass spectrometer, gas chromatograph, and autosampler contribute to instrument stability. 142 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 7 Diagnostics and Troubleshooting Troubleshooting Sample preparation, spiking errors, sample injection errors, and lack of routine maintenance on the instruments can cause false stability issues. When hardware faults affect instrument stability, investigate simple solutions first, such as cleaning the ion volume and lenses, or checking for air leaks. Usually, a hardware fault that affects stability shows different issues than those which might be attributed to stability. Issue: The signal response is unstable or drops out unexpectedly. Possible causes/solutions • There is a problem with the filament or lens control. See “Filament and Lens Control Issues” on page 135 for more information. • There is an air leak. Check for leaks. See “High Vacuum Issues” on page 138 for more information. • There is a high vacuum problem. See “High Vacuum Issues” on page 138 for more information. • There is a contamination problem. See “Contamination Issues” on page 133 for more information. • Dust has collected in the electron multiplier or on the conversion dynode. Contact Thermo Fisher Scientific Technical Support. Tuning Issues You can suspect a tuning problem when Xcalibur Auto Tune - Calibration fails. Auto Tune Calibration performs several functions, and issues or error messages indicate different problems. Diagnostics can usually uncover a tuning problem. Issue: “Cannot find Calibration Gas” error message received. Possible causes/solutions • There is a mechanical problem with the ion source or lenses. Verify that an EI ion volume is installed. Verify correct orientation and cleanliness of ion volume. Verify cleanliness and correct operation of lenses. • Tune file settings are out of usable range. Restore default tune settings and calibration settings. Run Auto Tune - Calibration. See “Tuning and Calibrating” on page 63. • The calibration gas vial is empty. Add 100 μL (max) of calibration compound to calibration gas vial. See “Adding Calibration Compound” on page 117. Issue: The electron multiplier gain calibration fails. Possible causes/solutions • The electron multiplier has not been given sufficient time to outgas since venting. Allow more time to pump out. • The GC column flow is too high. Lower it to1 mL/min. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 143 7 Diagnostics and Troubleshooting Troubleshooting • The multiplier is near the end of its lifetime. Multipliers typically last about 2 to 3 years before they are too noisy for the gain to be set accurately. Contact Thermo Fisher Scientific Technical Support. • The multiplier power supply is faulty. Contact Thermo Fisher Scientific Technical Support. • The filament is the source of too much background noise. See “Filament and Lens Control Issues” on page 135 for more information. • Chemical background in the manifold is elevated. Remedy leaks or sources of water contamination in carrier gas. See “High Vacuum Issues” on page 138 for more information. • The difference between the electron energy and the setpoint is greater than 5 V. Contact Thermo Fisher Scientific Technical Support for assistance. Issue: Poor high mass response. Possible causes/solutions • Poor high m/z ion intensity because the ion source temperature is too high. Reduce the ion source temperature to reduce the amount of thermal decomposition and fragmentation of your analyte. • Poor high m/z ion intensity because of bad ion source lens settings. Run Auto Tune Calibration. See “Tuning and Calibrating” on page 63. • Helium pressure in the ion source is too high or low. Set flow to 1.0 mL per minute for most applications. • There is a vacuum leak. Find and repair any leaks. Be sure to check the transfer line fitting in the GC oven. See “High Vacuum Issues” on page 138 for more information. • An excess amount of low m/z ions, such as hydrocarbons or column bleed. Remedy the source of these low m/z ions. • The ion volume or lenses are contaminated. Clean the ion volume or lenses. See “Cleaning Ion Source Components” on page 85. • m/z 131 is not base peak because the multiplier gain is too low. The multiplier gain calibration may set the multiplier voltage too low for a noisy multiplier. Electron multipliers older than 2 to 3 years are often noisy. Contact Thermo Fisher Scientific Technical Support. • There is poor high m/z intensity and poor resolution of low m/z ions because the conversion dynode is faulty. Contact Thermo Fisher Scientific Technical Support. • The injection rf is not calibrated. Run Auto Tune - Calibration as described in “Tuning and Calibrating” on page 63. • There is a problem with the filament or lens control. See “Filament and Lens Control Issues” on page 135 for more information. 144 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 7 Diagnostics and Troubleshooting Replacing a Fuse • Reagent gas is leaking into the analyzer, suppressing EI signal. Check for the presence of CI Reagent ions in spectrum. Replace the CI Reagent Gas Flow Module if necessary. Issue: Weak signal. Possible causes/solutions • The ion volume or ion source lenses are dirty. Clean the contaminated components as described in “Cleaning Ion Source Components” on page 85. • The multiplier is set too low. Run multiplier gain calibration in Auto Tune - Calibration as described in “Tuning and Calibrating” on page 63. An electron multiplier older than 2–3 years may be too noisy for the multiplier gain calibration to accurately set the voltage. The electron multiplier might need to be replaced. Contact Thermo Fisher Scientific Technical Support. • The wrong type of ion volume is installed. EI and CI require different ion volumes. They may not be used interchangeably. Change the ion volume as described in “Changing Ionization Modes” on page 73. • The ion volume is absent or incorrectly positioned. Verify that the ion volume is positioned correctly. • There is a filament or lens control problem. See “Filament and Lens Control Issues” on page 135 for more information. • The electron multiplier is faulty. Contact Thermo Fisher Scientific Technical Support. Replacing a Fuse CAUTION Fuses protect the various circuits by opening the circuits whenever overcurrent occurs. On the TSQ Quantum XLS and TSQ Quantum GC mass spectrometers, a failed fuse indicates a failed board or electronic module that must be replaced by a Thermo Fisher Scientific Field Service Engineer. Replacing PCBs and Power Supplies CAUTION The TSQ Quantum XLS and TSQ Quantum GC mass spectrometer electronic assemblies are close-packed to minimize the size of the system. Due to the complexity of removing and reinstalling the mass spectrometer electronic assemblies, only a Thermo Fisher Scientific Field Service Engineer can replace electronic assemblies. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 145 7 Diagnostics and Troubleshooting Replacing PCBs and Power Supplies 146 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 8 Using the Direct Sample Probe With the direct sample probes (direct insertion probe and direct exposure probe) you can introduce compounds directly into the ion source without GC column separation. This chapter covers, step-by-step, a direct insertion probe (DIP) experiment using perfluorotetracosane (CF3(CF2)22CF3, molecular weight 1238.18, melting point 190 ºC). You can perform a similar experiment using your compound. P Contents • Creating an Instrument Method • Creating a Sequence • Preparing the Probe and Inlet Valve • Preparing the Mass Spectrometer • Running the Sequence • Examining the Raw Data in Qual Browser • Removing the Probe Creating an Instrument Method An instrument method contains the settings that the TSQ Quantum XLS or TSQ Quantum GC mass spectrometer uses during an experiment. Use the Instrument Setup view to create the instrument method. Y To create an instrument method 1. On the Xcalibur Home Page, click the Instrument Setup icon to open the Instrument Setup view. 2. Click the TSQ icon in the viewbar. 3. Choose TSQ > Regular Method to open the regular method Scan Editor page. 4. On the Scan Editor page, create a one segment, one scan event instrument method. In this example, the segment is 8 minutes long (see Figure 65). Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 147 8 Using the Direct Sample Probe Creating an Instrument Method 5. Specify the mass spectrometer settings, for this example, full-scan scan type, Q1MS scan mode, and positive polarity. Figure 65. Scan Editor page of Instrument Setup 6. Click the EI/CI tab to display the EI/CI page (see Figure 66). 148 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 8 Using the Direct Sample Probe Creating an Instrument Method Figure 66. EI/CI page of Instrument Setup 7. Enter or select the following settings: • Number of States: 1 • State at Start of Run: On • Calibration Gas Setting: Off • Use DIP/DEP Probe: This example is an EI experiment with a 200 μA emission current. 8. Save the instrument method. a. Choose File > Save As to open the Save As dialog box. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 149 8 Using the Direct Sample Probe Creating a Sequence b. Save the instrument method as a .meth file. In this example we name the instrument method Dip test.meth. Creating a Sequence A sequence contains sample information—one sample per row. In this example the sequence has one sample. Note If the sequence has more than one sample, Xcalibur prompts you to reload the probe after each sample. Y To create a sequence 1. On the Xcalibur Home Page, click the Sequence Setup icon to open the Sequence Setup view (see Figure 67). 2. Enter the name and path of the instrument method. In this example, it is C:\Xcalibur\methods\DIP test. 3. Enter a file name and path for the raw file that contains the acquired data. In this example, it is C:\Xcalibur\Data\data01. Figure 67. Sequence Setup view, showing one sample in the sequence 150 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 8 Using the Direct Sample Probe Preparing the Probe and Inlet Valve Preparing the Probe and Inlet Valve Y To prepare the probe and inlet valve 1. Connect the direct sample probe controller to the mass spectrometer by contact closure with the probe start cable (P/N 70111-63627, in TSQ Quantum XLS or TSQ Quantum GC Accessory Kit). 2. Create a probe method on the controller. Refer to the probe manual. This example uses the following DIP settings: • Initial temperature: 50 ºC • Initial time: 5 s • Ramp rate: 100 ºC/min • Final temperature: 200 ºC • Ramp hold time: 200 s 3. Load sample on the probe. 4. Install the guide bar. a. With the guide ball track facing left, insert the guide bar into the entry housing. See Figure 16 on page 29. b. Push the guide bar in as far as it goes. Rotate it 90° clockwise to lock the guide bar in the entry housing. 5. Prepare the inlet valve. a. Make sure the inlet valve is closed with the inlet valve lever down, as shown in Figure 16 on page 29. b. Loosen the inlet valve knob counter-clockwise, and remove the inlet valve plug. Preparing the Mass Spectrometer Y To prepare the TSQ Quantum XLS for the experiment 1. Choose Start > All Programs > Thermo Instruments > TSQ > TSQ Tune to open the EZ Tune window if it is not already open. IMPORTANT The TSQ EZ Tune window must be open for the mass spectrometer to initiate the probe insertion sequence. 2. Ensure that the TSQ Quantum XLS or TSQ Quantum GC mass spectrometer is the only instrument in use and that there are no start instruments. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 151 8 Using the Direct Sample Probe Preparing the Mass Spectrometer a. On the Xcalibur Home Page, click the Sequence Setup icon to open Sequence Setup, if it is not already open. b. In Sequence Setup, choose Actions > Run Sequence. The Run Sequence dialog box opens (see Figure 68). Figure 68. Run Sequence dialog box, showing instruments in use c. Click Change Instruments to open the Change Instruments In Use dialog box. 152 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 8 Using the Direct Sample Probe Running the Sequence Figure 69. Change Instruments In Use dialog box, showing the TSQ Quantum mass spectrometer in use and no start instruments d. Click any Yes in the In Use column to clear all instruments other than the TSQ Quantum. e. Ensure that the TSQ Quantum has a Yes in the In Use column. Click the area if necessary. f. Click any Yes in the Start Instrument column to clear all start instruments. g. Click OK to save your settings and close the Change Instruments In Use dialog box. Running the Sequence You acquire data by running the sequence. Xcalibur saves the acquired data in a raw file. Note You must have the TSQ EZ Tune or QuickQuan application running so that Xcalibur can display instrument methods. Y To run the sequence 1. In the Run Sequence dialog box (see Figure 68 on page 152), click OK to start the acquisition. Xcalibur displays the Insert Probe message. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 153 8 Using the Direct Sample Probe Running the Sequence Figure 70. Insert Probe message 2. Inset the probe into the inlet valve. a. Insert the guide ball on the DIP probe into the guide ball hole on the guide bar. b. Slide the probe forward into the inlet valve until the guide ball is at the guide bar’s first stop. See Figure 71. c. Tighten the inlet valve knob clockwise to ensure a leak-tight seal. Figure 71. Probe at the first stop on guide bar 3. Click OK. The forepump evacuates the inlet valve. 4. When the Safe to Open Valve message to appears, click OK. 154 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 8 Using the Direct Sample Probe Running the Sequence Figure 72. Safe to Open Valve message 5. Pull the inlet valve lever up to open the inlet valve. 6. Slide the probe into the vacuum manifold until the tip of the probe is fully inserted into the ion volume holder. See Figure 73. Figure 73. Probe inserted into the inlet valve 7. When you receive the Acquisition Ready message, click OK. The TSQ Quantum XLS is now waiting for contact closure. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 155 8 Using the Direct Sample Probe Running the Sequence Figure 74. Acquisition Ready message . 8. In Sequence Setup, choose View > Real Time Plot View to display the mass spectrum and chromatogram. 9. Start the probe method from the probe controller to initiate data acquisition. See Figure 75 and Figure 76. Figure 75. Perfluorotetracosane mass spectrum at 0.56 minute retention time 156 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 8 Using the Direct Sample Probe Examining the Raw Data in Qual Browser Figure 76. Perfluorotetracosane chromatogram Examining the Raw Data in Qual Browser You can use Qual Browser to display the mass spectrum at various times in the chromatogram. Y To examine the raw data 1. On the Xcalibur Home Page, click the Qual Browser icon to open the Qual Browser window. 2. Click on the chromatogram to display the mass spectrum at that retention time. See Figure 77. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 157 8 Using the Direct Sample Probe Removing the Probe Figure 77. Raw file displayed in Qual Browser Removing the Probe Y To remove the probe 1. Withdraw the probe until the guide ball on the probe reaches the first stop on the guide bar (Figure 71). 2. Close the inlet valve by pushing the lever down. CAUTION Close the inlet valve first. Otherwise, the system vents to the atmosphere. Do not withdraw the probe beyond the point where the guide ball reaches the first stop in the guide bar. 3. Loosen the inlet valve knob by turning it counter-clockwise. 4. Continue withdrawing the probe completely from the inlet valve by sliding it through the guide ball track in the guide bar. 158 TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific 8 Using the Direct Sample Probe Removing the Probe 5. Store the probe in its case. 6. Remove the guide bar by rotating it 90° counter-clockwise and sliding it out of the entry housing. 7. Replace the inlet valve plug and tighten the inlet valve knob clockwise to form a seal. The inlet valve plug prevents air from entering the vacuum manifold in case the inlet valve is accidentally opened. You can also remove the inlet valve lever by pulling it free. Thermo Scientific TSQ Quantum XLS and TSQ Quantum GC User Guide 159 9 Replaceable Parts and Consumables This chapter contains TSQ Quantum XLS and TSQ Quantum GC part numbers for replaceable parts and consumables. To ensure proper results in servicing the TSQ Quantum XLS or TSQ Quantum GC mass spectrometer, order only the parts listed or their equivalent. Contact Thermo Fisher Scientific San Jose and have your TSQ Quantum XLS or TSQ Quantum GC serial number ready. These kits with replaceable parts and consumables are available for the TSQ Quantum XLS and TSQ Quantum GC: Contents • Accessory Kit • Chemicals Kit Accessory Kit Table 7. Accessory Kit (P/N 70111-62077) (Sheet 1 of 2) Description Thermo Scientific Function Part number Fitting, ferrule, SWG, 1/8 in., brass, set 00101-08-00009 Fitting, connection, 1/4 to 1/8 in. 00101-01709 Fitting, connection, 1/4 to 1/8 in. 00101-01712 Fitting, ferrule, SWG, front, 3/8 in., brass 00101-11500 Ferrule, 0.4mm ID × 1/16 00101-18100 Restek® capillary-grade hydrocarbon trap For removing hydrocarbons from the GC carrier gas 00106-99-00001 Restek high-capacity oxygen trap For removing oxygen from the GC carrier gas 00106-99-00002 Cotton swabs For applying cleaning paste to stainless steel parts 00301-01-00015 Tubing, 1/8 in., copper, pre-cleaned Gas lines 00301-22701 Ball valve seal kit (replacement) For replacing the ball valve seal in the inlet valve 119265-0003 TSQ Quantum XLS and TSQ Quantum GC User Guide 161 9 Replaceable Parts and Consumables Chemicals Kit Table 7. Accessory Kit (P/N 70111-62077) (Sheet 2 of 2) Description Function Part number Lens alignment tool For aligning ion source lenses 1, 2, and 3 120271-0001 Filament assembly For replacing a failed filament in the ion source 120320-0030 Nitrile gloves medium For handling clean parts that are under vacuum 23827-0008 Nitrile gloves large For handling clean parts that are under vacuum 23827-0009 Syringe, 10 uL, 80mm For adding calibration compound 36502019 Tee union, 1/8 in. 00101-01-00012 Cable, start, probe Contact closure cable between the direct sample probe and the mass spectrometer 70111-63627 Cable, start, GC Contact closure cable between the GC and the mass spectrometer 70111-63626 Forceps, 10 in., stainless steel For handling ion volumes and clean components 76360-0400 Cable, 10 base-T, crossover, 15-ft, shielded 76396-0052 Chemicals Kit Table 8. Chemicals Kit (P/N 70111-62078) 162 Description Function Part number Perfluorotributylamine (FC-43) Tuning and calibration compound 50010-02500 Aluminum Oxide Cleaning stainless steel parts 32000-60340 Benzohexane Performance testing 120150-TEST Octafluoronaphthalene Performance testing 120150-TEST TSQ Quantum XLS and TSQ Quantum GC User Guide Thermo Scientific I Index Symbols 133 A Accessory Kit 161 aluminum oxide 162 analyzer assembly, lenses, voltages applied to 39 analyzer chamber,location (figure) 43 Analyzer Control PCB, discussion 47 analyzer region, vacuum manifold, description 42 analyzer region, vacuum manifold, location 42 and 41 anode, electron multiplier, description 39 Auto Tune - Calibration 66 automatically 66 autosampler cofiguration 18 photo 2 power outlet 24 startup 55, 58 TriPlus 18 troubleshooting communication problems 133 AutoSIM scan type 14 B ball valve extraction tool (figure) 121 extraction tool, using 121 seal, replacing 121 ball valve seal kit 161 benzohexane 162 C cables 162 calibrating and H-SRM (note) 63 discussed 63 frequency (note) 63 Thermo Scientific running 66 tune and calibration report 69 calibration compound adding 117 flow control, description 46 mass spectrum, displaying 64 observed peaks 64 on, off 64 spectrum, positive EI mode 66 calibration compound vial location (figure) 118 removing and reinstalling 118 calibration gas valve, description 46 capillary column conditioning 125 installing 124 removing 122 removing ion source (Caution) 89, 96 cathode, electron multiplier, description 39 Cautions emergency shutdown 23, 51 forepump and line power 44 I/R tool removal, withdrawing 79 Ion Source PCB removal 109, 111 removing ion source and capillary column 89, 96 replacing fuses 145 replacing PCBs and power supplies 145 centroid scan, defined 15 chemical ionization (CI) discussed 4 gas valve, description 46 methane 4 removing ion volume 73 Chemicals Kit 162 circuit breaker 23–24 cleaning aluminum parts 115 ceramic parts 115 frequency 83 ion volumes 88 lenses L1, L2, L3, L4 88, 95 TSQ Quantum XLS User Guide 163 Index: D list (table) 83 stainless steel parts 113 collision cell figure 34 location (figure) 43 collision energy (Q2 offset voltage) 38 collision gas description 36 collision gas valve, description 45 collision-induced dissociation discussion 36 column bleed contamination 133 Communication LED description 22 figure 22 mass spectrometer reset 59 mass spectrometer startup 57 compliance regulatory iii WEEE vii computer, features 48 consumables 161 contamination column bleed 133 septum bleed 133 solvent ions 135 troubleshooting 133 Convectron gauge, description 45 conversion dynode description 39 figure 40 D data dependent scan mode, discussed 11 data system description 48 GC interface 48 instrument interface 48 LAN interface 49 personal computer 48 primary Ethernet adapter 48 shutdown 55 data types, discussed 14 detector system 39 diagnostics 129 running 129 DIP, example procedure 1 creating an instrument method 147 2 creating a sequence 150 3 preparing the probe and inlet valve 151 4 preparing the mass spectrometer 151 164 TSQ Quantum XLS User Guide 5 running the sequence 153 6 examining the data 157 perfluorotetracosane 147 direct insertion probe (DIP) perfluorotetracosane example procedure 147 direct sample probe and inlet valve 151 direct exposure probe (DEP) 20 direct insertion probe (DIP) 20 inserting into inlet valve (figure) 154 mass spectrometer, preparing 151 photo 20 using 147 dynode 39 E electron ionization (EI) discussed 4 removing ion volume 73 electron multiplier anode, description 39 description 39 figure 40 electronic assemblies description 46 ion detection system 47 Power Entry Module, description 46 RF voltage generation, description 47 electronics service switch description 24 location (figure) 24–25 mass spectrometer components On/Off status 60 embedded computer description 46 resetting 58 emergency shutdown Caution 23 front panel system power off button 23 procedure 51 system power off button 51 Ethernet 48 Ethernet Link OK LED 25 F FC-43 adding 117 mass spectrum, displaying 64 observed peaks 64 on, off 64 part number 162 spectrum, positive EI mode 66 Thermo Scientific Index: G ferules 161 filament description 28 location (figure) 26–27, 104, 106 on, off 64 part number 102, 105 problems, troubleshooting 135 replaceable parts 162 replacing 102, 105 filters 46 fittings 161 forepump description 44 maintainence 116 power cord (Caution) 44 forpump power outlet (figure) 25 front panel LEDs Communication 22 description 22 figure 22 Power 22 Scan 23 System 23 Vacuum 22 front panel system power off button figure 23 full scan type 12 functional description autosampler 18 data system 48 direct sample probes 20 gas chromatograph (GC) 19 inlet valve 29 ion optics 30 mass analyzer 32 mass spectrometer 21 Q0 quadrupole 30 transfer line 20 TSQ Quantum GC 17 fuses, mass spectrometer, replacing 145 G gas chromatograph (GC) capillary column, installing 124 capillary column, removing 122 column installation 124 communication with data system 48 configuring 19 functional description 19 leak check 125 photo 2 Thermo Scientific power outlet 24 startup 55–56 troubleshooting communication problems 133 guide bar figure 29, 74 intalling 73 H hydrocarbon trap 161 I inlet gasses hardware calibration compound 46 CI gas valve 46 collision gas valve 45 description 41 functional block diagram 41 inlet valve and direct sample probe 151 Caution 79 components (figure) 75 description 29 figure 29 guide bar 29 Insert Probe message 75 insertion/removal (I/R) tool, inserting 76 ion volumes, installing 80 lever, removing 82 plug orientation 82 procedure 74 Safe to Insert Probe message 77 Insert Probe message (figure) 75 insertion/removal (I/R) tool figure 29, 74 inserting 76 ion volumes, removing and installing 79 lock position 78 unlock position 74 withdrawal (Caution) 79 Instrument Configuration window, opening 18–19 instrument method, creating 147 intelligent selected reaction monitoring (iSRM) 13 ion detection system conversion dynode 39 description 39 electron multiplier 39 electron multiplier gain 40 electronic assemblies 47 ion gauge description 45 location (figure) 43 TSQ Quantum XLS User Guide 165 Index: L ion optics description 30 ion polarity modes,discussed 5 ion source cleaning 102, 105 cleaning components 85 cross sectional view (figure) 31 description 25 dissassembling completely 107, 110 electrical connections 89, 96 exploded view (figure) 86–87 figure 26–27 filament, replacing 102, 105 filament,replacing 102, 105 ion source lenses, reinstalling 94, 101 Ion Source PCB, location (figure) 108, 111 lens assembly, disassembling 92, 98 lens assembly, removing 91, 98 lenses, cleaning 88, 95 lenses, reassembling 93, 101 less assembly, exploded view 93, 100 location (figure) 89, 96 reinstalling 94, 102 removing 89, 96 ion source block location (figure) 26–27 ion source chamber location (figure) 43 Ion Source PCB location (figure) 26–27, 89, 96, 107, 110 reinstalling 109, 112 removal 109, 111 removal (Caution) 109, 111 ion transmission device defined 6 rod assembly 6 ion volumes attaching and removing from I/R tool 79 cleaning 88 figure 28 installing 80 location (figure) 81 removing 73 ionization modes changing 73 chemical ionization (CI) 3 discussed 3 electron ionization (EI) 3 iSRM scan type 13 L leak check, GC 125 166 TSQ Quantum XLS User Guide leak checking 138 LEDs Communication LED 22 Communication LED, mass spectrometer reset 59 Communication LED, mass spectrometer startup 57 Ethernet Link OK 24–25 Forepump On 24 Power LED 22 Power LED, mass spectrometer reset 59 Power LED, mass spectrometer startup 57 Pump On, location (figure) 25 Scan LED 23 System LED 23 System LED, mass spectrometer reset 59 System LED, mass spectrometer startup 57 Vacuum LED 22 Vent Valve Closed 24 Vent Valve Closed (figure) 25 lens alignment tool 161 lens L1, L2, L3, and L4 location (figure) 26–27 lenses analyzer assembly, voltages applied to 39 ion source lenses exploded view 93, 100 ion source lenses, reassembling 93, 101 ion source lenses, reinstalling 94, 101 L1, L2, L3 exploded view 93, 100 L1, L2, L3, L4 figure (TSQ Quantum XLS) 26 L1, L2, L3, L4 location (figure) 27 L1, L2, L3, L4, cleaning 88, 95 L21, L22, L23, figure 34 L31, L32, L33, figure 34 linearity problems, troubleshooting 139 M main power circuit breaker description 23–24 location (figure) 24 Maintaining 116 maintenance ball valve seal, replacing 120 forepump 116 frequency 83 GC column installation 124 ion source filament, replacing 105 ion source lenses, cleaning 88 ion volumes, cleaning 88 procedures (table) 83 mass analysis collision-induced dissociation 36 discussion 34 mass analyzer Thermo Scientific Index: N defined 6 description 32 quadrupole rod assembly, functional description 33 mass anaysis RF and dc fields (figure) 34 mass range 15 mass spectrometer and direct sample probe 151 CI gas valve 46 circuit breaker, location (figure) 25 collision gas valve 45 diagnostics 129 electronic assemblies 46 electronics service switch, location (figure) 25 emergency shutdown 51 front panel LEDs 22 functional description 21 fuses, replacing 145 inlet gasses hardware 41 inlet valve (figure) 29 ion detection system 39 ion detection system electronic assemblies 47 ion gauge 45 ion optics 30 ion source 26–27 LEDs and system startup 59 maintenance procedures (table) 83 mass analyzer 32 Off condition 60 On/Off status of components 60 Power Entry Module, description 46 power outlet 24 Q0 quadrupole 30 resetting 58 RF voltage generation electronic assemblies 47 right-side power panel 54 shutdown 53 Standby condition 52, 60 startup 55 turbomolecular pump 44 vacuum manifold 42 vacuum service switch, location (figure) 25 vacuum system 41 vent valve 45 mass spectrometer circuit breaker location (figure) 25 mechanical pump 44 MS main power circuit breaker mass spectrometer components On/Off status 60 MS/MS scan modes Neutral Loss 9 Parent 8 Product 7 Thermo Scientific N Neutral Loss scan mode discussed 9 example (figure) 11 illustration (figure) 10 O octafluoronaphthalene 162 Off condition, mass spectrometer components On/Off status 60 offset voltage, quadrupole 37 oxygen trap 161 P Parent 9 Parent scan mode discussed 8 illustration (figure) 8 Perfluorotetracosane 157 personal computer, features 48 phthalate contamination 133 power cord, forepump (Caution) 44 Power Entry Module, description 46 Power LED description 22 figure 22 mass spectrometer reset 59 mass spectrometer startup 57 power supply problems, troubleshooting 140 pressure, maximim allowed (table) 57 probe button 75 procedures adding calibration compound 117 changing ionization modes 73 cleaning ion source components 85 cleaning ion source lenses 88, 95 cleaning ion volumes 88 cleaning stainless steel parts 113 complete system shutdown 53 conditioning capillary columns 125 disassembling ion source lens assembly 92, 98 displaying FC-43 spectrum 64 dissassembling ion source completely 107, 110 emergency shutdown 51 GC leak checking 125 installing capillary column 124 installing the ion volume 80 maintaining forepump 116 operating the inlet valve 73 placing system in standby 52 reassembly ion source lenses 93, 101 TSQ Quantum XLS User Guide 167 Index: Q reinstalling ion source 94, 102 reinstalling ion source lenses 94, 101 reinstalling Ion Source PCB 109, 112 removing capillary column 122 removing ion source 89, 96 removing ion source lens assembly 91, 98 removing the ion volume 73 replacing filament 102, 105 replacing ion source filament 102, 105 resetting mass spectrometer 58 saving tune and calibration report 71 starting mass spectrometer 56 system startup 55 tuning and calibrating 66 Product scan mode discussed 7 illustration (figure) 8 profile scan, defined 14 pumps forepump 44 turbomolecular pump 44 Q Q0 30 Q0 quadrupole cross sectional view (figure) 31 description 30 figure 30 location (figure) 43 Q1 33 Q1 quadrupole figure 33 scan modes 6 Q1MS and Q3MS scan modes 7 Q2 rod assembly figure 34 scan modes 6 Q3 quadrupole figure 33 scan modes 6 QED MS scan type 14 quadrupole 30 quadrupole mass analyzer functional description 33 quadrupole offset voltage 37 quadrupoles mass analysis 33 Q0, description 30 Q1 and Q3 33 RF and dc fields 34 RF and dc fields (figure) 34–35 Qual Browser 168 TSQ Quantum XLS User Guide direct sample probe data 157 reviewing data 157 quantitation-enhanced data-dependent MS (QED MS) scan type 14 R rear power panel location (figure) 52 reference SRM reactions 14 regulatory compliance iii removed 98 Replaceable 161 replaceable parts 161 Replacing 120 RF / dc voltages applied to mass analyzer, discussion 33 RF voltage generation, discussion 47 right side power panel figure 25 right-side power panel description 54 figure 54 rod assemblies description 34 ion transmission 6 mass analysis 6 mass analyzer(s), quadrupole 33 Q1, Q2, and Q3 (note) 7 roughing pump 44 S Safe to Open Valve message direct sample probe 154 safety precautions vii safety standards iii Save 68 scan data types centroid scan 15 profile scan 14 Scan LED description 23 figure 22 scan modes data dependent 11 discussed 5 mass spectrometer 5 Neutral Loss 9 Neutral Loss, example (figure) 11 Neutral Loss, illustrated (figure) 10 Parent 8 Parent, illustrated (figure) 9 Product 7 Thermo Scientific Index: T Product, illustrated (figure) 8 Q1MS and Q3MS 7 summary (table) 6 scan types AutoSIM 14 discussed 12 full scan 12 intelligent selected reaction monitoring (iSRM) 13 quantitation-enhanced data-dependent MS (QED MS) 14 selected ion monitoring (SIM) 12 selected reaction monitoring (SRM) 13 sectional 31–32 selected ion monitoring (SIM) scan type 12 selected reaction monitoring (SRM) scan type 13 sensitivity problems, troubleshooting 140 septum bleedcontamination 133 sequence 150 creating 150 direct sample probe, running 153 Sequence Setup view 150 shutdown data system 55 emergency procedure 51 emergency, front panel system power off button 23 mass spectrometer 53 non-emergency 53 side cover plate (vacuum manifold), description 43 solvent ions masses 135 solvents purity requirements viii spectrometer 14 square 33 stability problems, troubleshooting 143 stainless steel, cleaning 113 Standby condition mass spectrometer components On/Off status 60 placing system in 52 startup 55 autosampler 58 gas chromatograph (GC) 56 operating conditions, setting 58 switch 24 System Control PCB, description 46 System LED figure 22 mass spectrometer reset 59 mass spectrometer startup 57 system power off button emergency shutdown 23 location (figure) 52 system reset button description 24 Thermo Scientific location (figure) 24 mass spectrometer reset 59 system shutdown emergency procedure 51 System Tune and Calibration workspace figure 66 T tables Accessory Kit 161 Chemicals Kit 162 mass spectrometer components on/off status 60 mass spectrometer maintenance procedures 83 maximum allowed pressures 57 summary of scan modes 6 the 46 TRACE GC Ultra gas chromatograph configuration 19 photo 2 transfer line capillary column, removing 123 cross sectional view (figure) 31 figure 21 functional description 20 location (figure) 89, 96 union (figure) 123 TriPlus autosampler cofiguration 18 photo 2 troubleshooting autosampler communication 133 communication 131 contamination 133 filament and lens control 135 gas chromatograph communication 133 heated zones 136 high vacuum 138 leak checking 138 linearity 139 power supplies 140 sensitivity 140 stability 143 tuning 143 TSQ Quantum GC autosampler 18 calibrating 63 data system 48 data types 14 diagnostics 129 front panel LEDs 22 functional block diagram (figure) 17 functional description 17 TSQ Quantum XLS User Guide 169 Index: V gas chromatograph 19 ion polarity modes 5 LEDs and system startup 59 mass range 15 mass spectrometer 21 operating conditions, setting 58 overview 1 photo 2 scan modes 5 scan types 12 shutdown 55 Standby condition 52–53 startup 55 tuning 63 TSQ Tune Master Application diagnostics 129 tune and calibration report figure 70 saving 69 tuning discussed 63 frequency (note) 63 running 66 tune and calibration report 69 tuning problems, troubleshooting 143 turbomolecular pump, description 44 powering off 24 problems, troubleshooting 138 turbomolecular pump 44 Vacuum LED 22 vacuum service switch 24 vent valve 45 vent valve description 45 LED 24 Vent Valve Closed LED 24 voltages conversion dynode 39 Q0 offset 30 quadrupole RF and DC 34 W WEEE compliance vii V Vacuum LED and analyzer region pressure 22 description 22 figure 22 vacuum manifold description 42 location (figure) 43 side cover plate, description 43 vacuum pumps forepump 44 turbomolecular pump 44 vacuum service switch description 24 location (figure) 25 On/Off status of mass spectrometer components 60 vacuum system collision gas valve 45 Convectron gauge 45 description 41 forepump 44 functional block diagram (figure) 42 ion gauge 45 leak checking 138 maximim allowed pressures 57 170 TSQ Quantum XLS User Guide Thermo Scientific
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement