Ekey home CP WM 1, CP WM 3, CP IN 1, CP IN 2 Access control system, Finger scanner, home keypad integra 2.0 Code pad Operating instructions

Ekey home CP WM 1, CP WM 3, CP IN 1, CP IN 2 Access control system, Finger scanner, home keypad integra 2.0 Code pad Operating instructions
Add to My manuals

Below you will find brief information for Access control system ekey home CP WM 1, Access control system ekey home CP WM 3, Access control system ekey home CP IN 1, Access control system ekey home CP IN 2. This document describes how to install, configure and operate the ekey access control system. The access control system can be programmed for opening doors, using either fingerprint authentication or PIN codes. It also features a variety of settings to customize its operation, including relay switching times, LED intensity, and the ability to create individual user profiles with multiple access methods. The document provides detailed information on all aspects of the system, including troubleshooting tips and maintenance instructions.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

ekey home CP WM 1, CP WM 3, CP IN 1, CP IN 2 Operating Instructions | Manualzz

ekey home

en

OPERATING INSTRUCTIONS

01

English

Translation of the original instructions - ID171/497/0/339

Table of contents

General ..........................................................................................3

Note ........................................................................................... 3

Product liability and limitation of liability ......................................... 3

Warranty and manufacturer's guarantee ......................................... 3

Notices, symbols, and abbreviations ..............................................3

Safety information .........................................................................5

Risk of electrocution ..................................................................... 5

Tamper-proofing .......................................................................... 5

Product description .......................................................................5

System overview .......................................................................... 5

Scope of delivery.......................................................................... 6

Proper use and area of application .................................................. 6

Finger scanner ............................................................................. 6

Code pad..................................................................................... 9

Control panels............................................................................ 10

Technical specifications ...............................................................13

Installation ..................................................................................15

Commissioning ............................................................................15

Commissioning devices and establishing normal mode .................... 15

Performing test mode ................................................................. 17

Operating concept .......................................................................20

Usage of the finger scanner with the control panel menu ............20

Entering the security code ........................................................... 21

Changing the security code .......................................................... 22

Setting the LED intensity ............................................................. 23

Setting relay switching times ....................................................... 24

Setting the digital input ............................................................... 25

Storing fingers and RFID transponders .......................................... 26

Opening a door .......................................................................... 31

Deleting users ............................................................................ 33

Deleting RFID transponders ......................................................... 33

Performing demo mode ............................................................... 34

Performing trade fair mode .......................................................... 34

Calling the serial and version numbers .......................................... 36

Usage of the finger scanner with the app ....................................37

Downloading the app .................................................................. 37

en│1

2│en

Coupling the smartphone/ tablet for the first time .......................... 38

Deactivating Bluetooth ................................................................ 39

Coupling additional smartphones/ tablets ...................................... 39

Managing multiple Bluetooth finger scanners ................................. 40

Storing a user coupling code ....................................................... 40

Resetting the app security code ................................................... 41

Protecting the system in the event that the smartphone/ tablet is lost

............................................................................................... 41

Opening a door .......................................................................... 42

Usage of the code pad with shortcuts .......................................... 43

Entering the admin code ............................................................. 43

Changing the admin code ............................................................ 44

Setting the automatic back-illumination ........................................ 46

Setting the brightness of the back-illumination .............................. 47

Setting the signaling that indicates when a button has been pressed 48

Setting an acoustic signal for opening ........................................... 49

Storing a user code .................................................................... 50

Opening a door .......................................................................... 52

Deleting the user code ................................................................ 53

Performing demo mode ............................................................... 54

Performing trade fair mode ......................................................... 55

Reset the system to default settings ........................................... 56

Via the control panel .................................................................. 57

Via the code pad ........................................................................ 58

Via the app ............................................................................... 59

Updating the software ................................................................. 59

Error displays and troubleshooting .............................................. 60

Control panel ............................................................................. 60

Finger scanner ........................................................................... 61

Code pad .................................................................................. 62

Maintenance ................................................................................ 63

Disposal ....................................................................................... 63

Declaration of conformity ............................................................ 63

Copyright ..................................................................................... 63

General

ekey biometric systems GmbH operates a quality management system in compliance with EN ISO 9001:2008 and is certified accordingly.

These instructions form a component of the product. Ensure that they are stored in a safe place. Please contact your dealer for further information about the product.

Safe operation and function of the devices can be impaired in the following situations. Liability due to malfunctioning is transferred to the operator/user in such cases:

□ The system devices are not installed, used, maintained, or cleaned in accordance with the instructions

□ The system devices are not used within the scope of proper use

□ Unauthorized modifications are carried out on the system devices by the operator.

These operating instructions are not subject to updating. We reserve the right to make technical modifications and change the product's appearance; any liability for errors and misprints is excluded.

The version of our general terms and conditions in force on the date of purchase shall apply. See http://www.ekey.net

.

Note

Product liability and limitation of liability

Warranty and manufacturer's guarantee

Notices, symbols, and abbreviations

NOTICE

Denotes additional information and useful tips.

DANGER

Denotes imminent danger which could lead to death or serious injuries.

ATTENTION

Denotes possible property damage which cannot result in injuries. en│3

4│en

Symbols:

1. Step-by-step instructions

References to sections of these instructions

References to the mounting instructions

Displayed value

References to the wiring diagram

Listing without specified order, 1st level

Displayed values

ekey home

FS OM

MENU ITEM

Button

Product names

Menu items

Buttons

Abbreviations and terminology:

WM

FAR

FRR

FS

IN

RFID

CP

Sn.

OM

Vn.

Wall-mounted

False Acceptance Rate

False Rejection Rate

Finger scanner integra

Radio-Frequency Identification

Control panel

Serial number

Outlet-mounted

Version number

Fingerprint The biometric information extracted from the fingerprint

Safety information

DANGER

All ekey home devices are to be operated with safety extra-low voltage (SELV). Only use power supplies rated protection class 2 according to VDE 0140-1.

Failure to do so will create a risk of fatal electrocution.

Only certified electricians are authorized to carry out the electrical installation work!

Mount the control panel in a secure internal area. This prevents tampering from the outside.

Risk of electrocution

Tamperproofing

Product description

System overview

Fig. 1: Overview of the system

1 Connecting cable from registration unit to control panel

2 Power supply

3 Registration unit (finger scanner or code pad)

4 Control panel

5 Distributor

6 Motorized lock

7 Cable transfer

8 Connecting cable from control panel to motorized lock en│5

Scope of delivery

Proper use and area of application

Finger scanner

□ Registration unit (finger scanner or code pad)

□ RFID transponder for finger scanners with RFID function

□ Control panel

□ Operating instructions, mounting instructions, wiring diagram

□ Optional: matching accessories (cable transfer, power supply, connecting cable, covers, etc.).

This product is an access control system with a biometric or mental identification feature (finger scan or pin code). The system is comprised of a registration unit and control panel. It is available in various models and component combinations.

The finger scan access control system detects the characteristics of the fingerprint contours, compares them to the stored fingerprint image, and opens the door in the event of a match. One particular makeup allows the user to be identified and the door opened by means of an RFID transponder.

The non-physical access control system detects the pin codes which are entered, compares them to the stored reference codes, and opens the door in the event of a match.

The system is primarily designed for opening house doors, apartment doors, and garage doors in homes and businesses.

Function of the finger scanner

1 Front phalanx

2 Fingerprint

Fig. 2: Fingerprint

The finger scanner detects the fingerprint by means of a line sensor and subsequently processes it. It then compares the result with the stored fingerprint image. The finger scanner only works correctly and reliably with the front phalanx print. Swipe your finger steadily and evenly over the sensor in the correct position.

The makeup with RFID function detects and identifies RFID transponders.

6│en

Finger scanner controls

Controls Function

Finger swipe area

Sensor

Store fingers by 'swiping the finger' evenly downward over the sensor.

Identification by 'holding up the RFID transponder', which involves holding an RFID transponder over the finger swipe area of the finger scanner.

System programming by 'Finger Touch', a short, rapid touch of the sensor with the finger.

Finger scanner controls Table 1:

1 Right guiding edge

2 Sensor

3 Left guiding edge

Fig. 3: Finger swipe area

Correct operation of the finger scanner

Incorrect operation will impair the function of the finger scanner.

'Swiping the finger':

Step

1st

Figure Description

Hold your finger straight and place it centrally between the guiding edges. Do not twist the finger.

2nd

3rd

4th

Place the joint of the front phalanx directly onto the sensor. Place your finger flat onto the finger swipe area.

Stretch out the neighboring fingers.

Move your finger evenly downward over the sensor. Move the whole hand simultaneously. Swipe the front phalanx fully over the sensor in order to achieve optimal results. The movement takes approx. 1 second. en│7

General hints for achieving a good-quality fingerprint

8│en

□ Recommended finger numbering: .

□ The index, middle, and ring fingers work best. The thumb and small finger work marginally or not at all.

□ If the fingers are frequently wet, store the images with wet fingers.

□ Children's fingerprints work from approx. 5 years of age.

'Finger Touch':

Step Figure

1st

Description

Briefly touch the sensor with your finger.

'Holding up the RFID transponder':

NOTICE

The 'holding up the RFID transponder' option is only available for finger scanners with an RFID function.

Step

1st

Figure Description

Hold the RFID transponder face parallel to the finger swipe area of the finger scanner at a distance of 1 to 5 cm.

Optical signals on the finger scanner

There are 2 types of LED:

□ Status LED for operating status

□ Function LED for indicating the function of the overall system.

1 Status LED

2 Function LEDs

Fig. 4: Optical signals on the finger scanner

Function of the code pad

The code pad captures the pin code by means of the capacitive keypad. It compares what has been entered with the stored reference codes. The code pad can handle pin codes containing 4 to 8 digits. The digits in the pin code cannot all be the same; at least one of them must be different.

There are 2 types of pin code: The admin code for configuring the system and the user code for opening the door.

Controls, optical signals, and acoustic signals on the code pad

The code pad has 2 sections with controls.

Controls Function

Input buttons

Enter pin code; select menu item.

Confirmation buttons Confirm pin code input as positive or negative; start menu.

Table 2: Code pad controls

2 status LEDs signal the operating statuses (pin code correct, pin code incorrect, menu item, etc.). An acoustic signal transmitter signals that the button has been pressed and that access has been enabled.

1 Left status LED

2 Right status LED

3 Input buttons

4 Confirmation buttons

Code pad

Fig. 5: Code pad overview

The back-illumination of the keypad is blue, dimmable, and switches on or off according to the lighting conditions. en│9

Control panels

Admin menu for the code pad

There is a range of menu items available in the Admin menu for programming purposes. These can be called via the buttons.

Button Menu item

Change admin code

Reset the system to default settings

Set the code pad (back-illumination, acoustic and optical signal when button is pressed, acoustic signal on opening)

Table 3: Admin menu for the code pad

The control panels are available in 2 models, each with 2 relay variants.

You can only operate a single registration unit per control panel. Any registration unit works with any control panel.

Product name

ekey home

CP WM 1 ekey home

CP WM 3 ekey home

CP IN 1 ekey home

CP IN 2

Figure

Mounting type

Wall mounting,

1 relay

Wall mounting,

3 relays

Can be integrated,

1 relay,

1 digital input

Can be integrated,

2 relays,

1 digital input

Table 4:

Controls

Control panel models and variants

Function of the control panel

The control panel is the actuator of the system. It serves to switch one or more relays.

Control panel controls

Function

Seven-segment display and 4 buttons

Table 5:

Programming and configuring, relay control.

Control panel controls

10│en

1 Seven-segment display

2 Keypad

Fig. 6: Overview of the ekey home CP WM and the ekey home CP

IN

Button

Name

OK Arrow pointing to the left

Function

Table 6:

Save values, jump to the next menu level.

Navigate in the menu, set values.

Control panel programming buttons

Arrow pointing to the right

Navigate in the menu, set values.

ESC

Leave a menu level, cancel input. en│11

12│en

Menu items

The control panel offers various menu items:

Enroll user Stores users, fingers, RFID transponders, and user codes.

Delete user Deletes all data for a user.

Security code Changes the security code.

Information

Reset

Calls the serial and version number.

Resets the system to default settings.

Sets the relay switching times. Relay time

Input

LED intensity

Sets the digital input (only for ekey

home control panel integra)

Sets the LED intensity (does not apply for the ekey keypad)

Performs test mode Test mode

Demo mode Performs demo mode

Trade fair mode Performs trade fair mode

Technical specifications

Name

Supply voltage

Unit

VDC

Values

8-24

Power

W Minimal (heating off): 1

Maximal (heating on): 4 (WM,

OM), 3 (IN)

-25 to +70

Operating temperature

Memory

°C

Security

Fingers 99

RFID transponders

99 (only for FS with RFID function)

FAR

FRR

1:10,000,000

1:100

IP code

IP WM: 44

IN: 54 (front side)

Typical recognition period

s

OM: 44 (with ekey frame OM)

1

RFID (only for finger scanners with RFID function)

Table 7:

Range

Standard

30 mm

ISO14443A

Transponder type

MIFARE DESFire EV1 with at least

1 KB of memory

Technical specifications: ekey home finger scanner en│13

14│en

Name

Supply voltage

Power rating

Operating temperature

Memory

Unit

VDC

W

°C

Pin codes

Values

8-24

1

-25 to +70

99

Pin code length

Quantity 4-8 digits

IP code

Table 8:

Name

IP 54 (front side)

Technical specifications: ekey home keypad integra 2.0

Unit Values

ekey home

CP WM ekey home

CP IN

Supply voltage

Power rating

VDC

W

Relay

Quantity

Switching voltage relay VDC

8-12

1

1 (3)

42

8-24

1

1 (2)

42

Switching current relay A 2 2

Operating temperature °C

IP code

IP

-20 to +70

20

-20 to +70

20

Digital inputs

Table 9:

Quantity - 1 (potential free)

Technical specifications: ekey home control panel WM/IN

Installation

ATTENTION

Mount and cable the product correctly before connecting power.

Failure to do so will create a risk of possible property damage!

Do not connect the power supply beforehand!

Mount the system in accordance with the supplied mounting instructions.

Cable the system in accordance with the supplied wiring diagram.

Step Action

1st Ensure safe installation of the devices.

Close the covers.

Display

-

Commissioning

Commissioning the devices couples the control panel and the registration unit with one another.

Step

1st

2nd

Action Description

Connect the power supply to the mains.

No action required.

Default setting.

Display

The control panel counts backwards.

3rd

4th

5th

No action required.

Default setting.

Press

Press

OK .

ESC . The control panel is ready to store a finger, user code, or RFID transponder.

The status LED of the finger scanner flashes orange and the status

LEDs of the code pad flash yellow alternately.

2 points light up.

1 point lights up on the right.

For a finger scanner.

For a code pad.

Commissioning devices and establishing normal mode

en│15

16│en

Step

6th

Action Description

Variant a For a new installation: Press

ESC .

Display

-

Variant b

/

/ or

For an installation after the control panel has been replaced:

Swipe a pre-stored finger over the finger scanner;

OR enter a pre-stored user code on the keypad;

OR hold a stored RFID transponder in front of the finger swipe area on the finger scanner.

Fingers, user codes, and

RFID transponders are not deleted.

OR press ESC : All existing fingers, user codes, and

RFID transponders are deleted.

7th No action required.

- 1 point flashes on the left.

The devices have now been commissioned and are in normal mode.

If you are using a Bluetooth finger scanner, the finger scanner is ready to create the coupling between the finger scanner and smartphone/tablet.

NOTICE

The control panel automatically detects whether the finger scanner attached to it is a Bluetooth finger scanner. The control panel shows you whether your finger scanner is a Bluetooth finger scanner when you enter the security code.

See Entering the security code, page 21.

Test mode tests the overall system ( tG ) and the lock after it has been installed in the door ( tS ). It switches the relay(s) on and off and checks the electrical connections to the motorized lock.

NOTICE

A test can only take place if no smartphone/tablet has been coupled.

Testing the overall system

The test of the overall system is performed via the main menu. To get to the main menu, enter the security code.

See Entering the security code, page 21.

The system displays the main menu.

With a finger scanner

Step

1st

Action Description

Press < or displayed

> until tE is

Display

2nd

Press OK .

3rd

Press OK .

4th Swipe any finger over the sensor. All of the relays switch one after another for the defined relay switching time

(default setting: 3 s).

The finger scanner lights up red.

5th

Press ESC twice. 1 point flashes on the left.

The entire system has been tested. The system is in normal mode.

NOTICE

Test mode is terminated in the following cases:

□ If the finger scanner is not operated for around 1 minute

□ If the system is disconnected from the power supply

Performing test mode

en│17

18│en

With a code pad

Step Action Description

1st

Press < or > until tE is displayed

2nd

Press OK .

3rd

Press OK .

4th Press any two buttons.

Display

-

5th Status

LEDs light up red.

6th

Press ESC twice.

The entire system has been tested. The system is in normal mode.

1 point flashes on the left.

NOTICE

Test mode is terminated in the following cases:

□ If the code pad is not operated for around 1 minute

□ If the system is disconnected from the power supply

Press

. All of the relays switch one after another for the defined relay switching time (default setting: 3 s).

Testing the lock

You can switch the relays individually. The test of the lock is performed via the main menu. To get to the main menu, enter the security code.

See Entering the security code, page 21.

The system displays the main menu.

Step

1st

Action Description

Press < or > until tE is displayed.

2nd Press OK .

3rd

Press < or > until tS is displayed.

4th

Press OK .

5th

Press OK . Relay 1 switches for the defined relay switching time (default setting: 3 s).

6th

Press < or > until o2 is displayed.

7th

Press OK . Relay 2 switches for the defined relay switching time (default setting: 3 s).

8th (Only for ekey home control panel 3)

Press < or > until o3 is displayed.

Display

9th

Press OK . Relay 3 switches for the defined relay switching time (default setting: 3 s).

10th

Press ESC 3 times.

The relays have been tested. The system is in normal mode.

NOTICE

Test mode is terminated in the following cases:

□ If the registration unit is not operated for around 1 minute

□ If the system is disconnected from the power supply

1 point flashes on the left.

en│19

20│en

Operating concept

Different operating concepts are available, depending on the registration unit:

□ ekey control panel menu – administration of the finger scanner by means of the control panel

ekey home app – administration of the Bluetooth finger scanner by means of a smartphone/tablet

□ ekey admin code – administration of the code pad by means of shortcuts.

Go to the operating concept that relates to the registration unit you have purchased.

See Usage of the finger scanner with the control panel menu, page 20.

See Usage of the finger scanner with the app, page 37.

See Usage of the code pad with shortcuts, page 43.

Usage of the finger scanner with the control panel menu

The devices must have been commissioned before you start your system administration.

See Commissioning devices and establishing normal mode, page 15.

The system is in normal mode. The control panel menu is used for programming the system.

Entering the security code grants you access to the main menu. The main menu is used to configure the system. The default security code is 99 .

You can also determine whether your finger scanner is a Bluetooth finger scanner by entering the security code.

ATTENTION

Change the default security code immediately after commissioning!

If you do not change the security code, it may be possible for unauthorized persons to get into your main menu and then gain access to your premises.

Choose a new security code and keep it secret.

See Changing the security code, page 22.

The system is in normal mode.

Step

1st

Action Description

Press OK .

2nd

Press < or > to select the first digit of the security code.

3rd Press OK .

4th

Press < or > to select the second digit of the security code.

Display

5th

Press OK . bt will only be displayed if your finger scanner is a Bluetooth finger scanner.

The system displays the main menu. It automatically switches back to normal mode if you do not press a button within 90 s.

NOTICE

If your finger scanner is a Bluetooth finger scanner, you can now choose a particular operating concept.

See Operating concept, page 20.

Entering the security code

en│21

Changing the security code

The security code can be changed via the main menu. To get to the main menu, enter the security code.

See Entering the security code, page 21.

The system displays the main menu.

Step Action Description

1st

Press < or > until Sc is displayed.

2nd

Press OK .

3rd

Press < or > to select the first digit of the new security code. E.g.: 2 .

4th Press OK .

5th

Press < or > to select the second digit of the new security code. E.g.: 5 .

6th Press OK .

The new security code is stored. The system is in normal mode.

Display

22│en

This function defines the intensity of the status LEDs on the finger scanner when in idle mode.

The LED intensity is set via the main menu. To get to the main menu, enter the security code.

Setting the

LED intensity

See Entering the security code, page 21.

The system displays the main menu.

Step Action Description

1st

Press < or > until LE is displayed.

2nd

Press OK .

3rd

Press < or > to select the desired

LED intensity. E.g.: 2 .

0 = LED off

1 = LED dimmed (default setting)

2 = LED on

4th

Press OK .

5th

Press ESC to return to the main menu.

Display

1 point flashes on the left.

The LED intensity is stored. The system is in normal mode. en│23

Setting relay switching times

The switching time for each individual relay can be set anywhere between

1 and 99 s. By default, the switching time is set to 3 s. When the time is set to 0 s, the relay operates as a switch: The relay changes its switching status when a finger is detected and it remains in that status until another finger is detected.

NOTICE

When controlling an intrusion alarm system with relay switching time =

0 , a power failure or reset will deactivate the intrusion alarm system. A reset is generated when you swipe an unrecognized finger over the finger scanner 10 times in a row.

The relay switching times are set via the main menu. To get to the main menu, enter the security code.

See Entering the security code, page 21.

The system displays the main menu.

Step

1st

Action Description

Press < or > until rt is displayed.

2nd

Press OK .

3rd

Press < or > to select the relay number.

Relay selection is available on control panels with more than one relay.

4th Press OK .

5th

Press < or > to set the relay switching time. E.g.: 10 .

Display

6th Press OK .

The relay switching times are stored. The system is in normal mode.

24│en

NOTICE

This function is only available for ekey home control panel integra.

The digital input of the control panel enables the following functions:

Request-to-exit button

The digital input functions as a remote opener for relay 1. In this case, the relay switches for the defined relay switching time or for as long as the digital input is enabled (e.g., request-to-exit button, permanent opening).

Feedback

The LEDs on the finger scanner indicate the status of the digital input for

30 seconds when an authorized finger is swiped over the sensor. If the digital input is enabled, the function LEDs light up red. If the digital input is disabled, the function LEDs light up green. If the status of the digital input changes within 30 seconds, this change is also signaled in the same way. This enables you to see that the alarm system is still appropriately sensitive, for example.

Block for relay 1

Relay 1 cannot be switched if the digital input is enabled (e.g., entrance blocking while the alarm system is enabled). The function LEDs on the finger scanner indicate the status of the digital input for 30 seconds when an authorized finger is swiped over the sensor. If the digital input is enabled, the function LEDs light up red. If the digital input is disabled, the function LEDs light up green. If the status of the digital input changes within 30 seconds, this change is also signaled in the same way. However, the relay does not switch automatically when the digital input changes from enabled to disabled.

The digital input is set via the main menu. To get to the main menu, enter the security code.

See Entering the security code, page 21.

Setting the digital input

en│25

Storing fingers and RFID transponders

The system displays the main menu.

Step Action Description

1st

Press < or > until IP is displayed.

2nd

Press OK .

3rd

Press < or > to select the desired function:

Fr = Request-to-exit button for relay 1;

A = Feedback for relay 1;

Ar = Block for relay 1.

E.g.: A .

Display

4th

Press OK .

The digital input has been set. The system is in the main menu.

The system enables a maximum of 99 fingers and 99 RFID transponders for a maximum of 99 users to be stored.

Storing fingers

Storing fingers allows the following actions to be taken:

□ Assigning a memory space to a user

□ Assigning a number to the finger ( F1 , F2 , ..., F9 , F0 )

□ Assigning a relay to the finger on the ekey home CP WM 3 and the ekey home CP IN 2

NOTICE

□ Store at least 2 fingers – one from each hand.

□ Create a list of users.

Fingers are stored via the main menu. To get to the main menu, enter the security code.

See Entering the security code, page 21.

26│en

The system displays the main menu.

Step Action Description

1st

Press < or > until Eu is displayed.

2nd

Press OK .

3rd

4th

Press < or > to select the user number. If the user has already stored a finger, a point lights up on the right.

Only for finger scanners with an RFID function:

Press OK .

5th

Press OK .

6th

Press < or > to select the finger number. If there is already a finger stored under this finger number, a point lights up on the right. The finger can be overwritten.

7th

Press OK .

8th

Press < or > to select the relay. od = double relay (relay 1 +

2). Relay selection is available on control panels with more than one relay.

Display

9th

Press OK . The control panel is ready to store the finger.

Status LED lights up orange en│27

28│en

Step

10th

11th

Action

or

Description

Swipe the finger over the sensor. Repeat this step at least twice. Between each individual finger swipe, the finger scanner lights up orange if the finger storing process is not complete.

The quality of the fingerprint is acceptable. However, it may be possible to improve the quality by swiping the finger again. Press OK if you want to end the finger storing process.

-

Display

/

/

Status LED lights up green/All

LEDs light up green.

Status LED and lefthand function

LED light up green.

Status LED lights up red/All

LEDs light up red.

Status LED lights up green, function

LEDs light up red.

Status LED lights up green, lefthand function

LED lights up red.

-

No action required.

The quality of the fingerprint is poor or the finger was not recognized. Swipe the finger over the sensor again.

-

-

Status LED lights up blue.

12th No action required.

To store more fingers or users, start again from step

1.

The fingers are stored. The system is in normal mode.

Storing RFID transponders

NOTICE

You can only store an RFID transponder for finger scanners with an RFID function.

An RFID transponder is able to trigger an action on the control panel, e.g., opening a door. You need a separate RFID transponder for each relay. The double relay function also requires a separate RFID transponder.

RFID transponders are stored via the main menu. To get to the main menu, enter the security code.

See Entering the security code, page 21.

The system displays the main menu.

Step

1st

Action Description

Press < or > until Eu is displayed.

2nd Press OK .

3rd

4th

Press < or > to select the user number. If the user has already stored a finger or an

RFID transponder, a point lights up on the right.

Press OK .

5th

6th

Press < or > until EC is displayed.

Press OK .

Display

en│29

30│en

Step

7th

Action Description

Press < or > to select the relay. o1 = relay 1 o2 = relay 2 o3 = relay 3 od = double relay (relay 1 +

2).

E.g.: o2 .

Relay selection is available on control panels with more than one relay. If there is already an RFID transponder stored under this relay, a point lights up on the right. The relay can be overwritten.

Display

8th

Press OK . The control panel is ready to store the RFID transponder.

Status LED lights up orange

9th Hold the RFID transponder over the finger swipe area of the finger scanner at a distance of 1 to 5 cm.

All LEDs light up green.

Short beep.

Status LED lights up orange.

Function

LEDs light up green.

Long beep.

Status LED lights up red. Long beep.

The RFID transponder was not stored. Either you did not hold the RFID transponder over the finger scanner for long enough, or it was not close enough, or this RFID transponder has already been stored. Repeat the procedure beginning at step 1.

-

10th No action required.

-

The RFID transponder is stored. The system is in normal mode.

Status LED lights up blue.

NOTICE

When a finger scanner or the control panel is replaced, the RFID transponders must be stored again.

The primary purpose of the product is to open doors. This can be carried out using the finger scanner, an RFID transponder, or the digital input.

The system is in normal mode.

Using the finger scanner

Step

1st

Action Description

Swipe a stored finger over the sensor.

Display

Status LED lights up green.

Status LED lights up red.

2nd No action required.

The finger was not recognized. Repeat step

1.

The door opens.

-

Status LED lights up blue.

The system is in normal mode.

Opening a door

en│31

32│en

Using an RFID transponder

NOTICE

You can only open a door using an RFID transponder for finger scanners with an RFID function.

Step

1st

Action Description

Hold a stored RFID transponder up to the finger swipe area of the finger scanner.

Display

Status LED lights up green. Short beep.

Status LED lights up red. Long beep.

2nd No action required.

The RFID transponder was not recognized.

Repeat step 1 with a valid RFID transponder.

Alternatively, hold the

RFID transponder closer to the finger scanner or for a longer period of time.

The door opens.

- -

Status LED lights up blue.

The system is in normal mode.

Using the digital input (request-to-exit button)

NOTICE

You can only open a door using the digital input with the control panel

ekey home CP IN.

You can also open the door using the request-to-exit button for the digital input on the ekey home CP IN. The relay switches for the defined relay switching time. If the digital input is enabled for longer than the defined relay switching time, the relay switches for as long as the digital input is enabled.

Deleting a user will delete all fingers and all RFID transponders stored under their user number. It is not possible to delete individual fingers or

RFID transponders from a user.

Users are deleted via the main menu. To get to the main menu, enter the security code.

See Entering the security code, page 21.

The system displays the main menu.

Step Action Description

1st

Press < or > until du is displayed.

2nd

Press OK .

3rd

Press < or

E.g.: 3 .

> to select the user number.

Display

4th

Press OK .

The user has been deleted. The system is in normal mode.

You cannot delete individual RFID transponders. You can only delete users. Deleting a user also deletes the RFID transponders.

See Deleting user, page 33.

Deleting users

Deleting RFID transponders

en│33

Performing demo mode

Performing trade fair mode

Demo mode makes it possible to attract the attention of visitors to trade fairs and in exhibition halls by means of finger scanner LEDs lighting up or flashing, constant switching of the control panel display, and relays switching.

Demo mode is executed via the main menu. To get to the main menu, enter the security code.

See Entering the security code, page 21.

The system displays the main menu.

Step Action Description

1st

Press < or > until dE is displayed.

2nd

Press OK .

3rd

Press < or > to select the desired demo variant: dL = demo LEDs – the LEDs light up and flash, and the control panel display switches constantly dr = demo relays – the LEDs light up and flash, the control panel display switches constantly, and the relays switch.

E.g.: dr .

Display

4th

Press OK . The selected demo variant starts.

5th

Press ESC twice to terminate demo mode and return to the main menu.

Demo mode has been executed. The system displays the main menu.

Trade fair mode simplifies the user storing process for demo purposes.

NOTICE

□ Operation is not possible once trade fair mode is enabled

□ The system automatically returns to trade fair mode after a power failure

□ Trade fair mode only switches relay 1

Trade fair mode is executed via the main menu. To get to the main menu, enter the security code.

See Entering the security code, page 21.

34│en

The system displays the main menu.

Step Action Description

1st

Press < or > until MM is displayed.

2nd

Press OK .

3rd

Press < or > to select the desired variant:

M1 = fingers deleted after detection or 10 minutes

M2 = fingers are stored for

10 minutes.

E.g.: M2 .

Display

4th

5th

6th

Press OK .

No action required.

The selected trade fair mode has been enabled.

Swipe the finger over the sensor.

-

Carry out a Finger Touch on the sensor.

/

Status LED lights up orange.

7th Status LED lights up green.

Status LED lights up red.

The quality of the fingerprint is poor or the finger was not recognized. Swipe the finger over the sensor again.

-

8th No action required.

- Status LED flashes blue.

9th

Press ESC twice to terminate trade fair mode and return to the main menu.

1 point flashes on the left.

Trade fair mode has been set and terminated again. The fingers stored while in trade fair mode have been deleted. The system displays the main menu. en│35

Calling the serial and version numbers

The serial ( Sn ) and version ( US ) numbers of the control panel ( CU ) and finger scanner ( FS ) are called via the main menu. To get to the main menu, enter the security code.

See Entering the security code, page 21.

The system displays the main menu.

Step

1st

Action Description

Press < or > until In is displayed.

2nd Press OK .

Sn.: No action required.

Go to step 3.

Vn.: Press > .

3rd Press OK .

4th

Press OK . The serial or version number of the control panel is displayed.

Display

-

/

5th

Press > 6 or 3 times until you have read the entire serial or version number.

-

6th

7th

Press ESC to return to the screen for selecting the serial or version number.

Press > .

8th

Press OK . The serial or version number of the finger scanner is displayed.

/

9th

Press > 6 or 3 times until you have read the entire serial or version number.

-

10th

Press ESC 3 times to return to the main menu.

The serial or version number has been displayed. The system displays the main menu.

36│en

Usage of the finger scanner with the app

NOTICE

The ekey home app can only be used in conjunction with the Bluetooth finger scanner.

The devices must have been commissioned before you start your system administration.

See Commissioning devices and establishing normal mode, page 15.

The finger scanner is ready to create the coupling between the Bluetooth finger scanner and the smartphone/tablet. The ekey home app is used for programming the system. Doors can also be opened via the app.

The app is available for Apple iOS and Google Android. Download the ekey

home app from the App Store or Google Play. To find it, enter the search term ekey home app .

Downloading the app

en│37

Coupling the smartphone/ tablet for the first time

You need security codes for the coupling. The default admin coupling code and app security code is 9999 .

NOTICE

For security reasons, you must change the admin coupling code to a 6digit code the first time you perform the system admin coupling process.

Make a note of this code, as you will need it to couple additional smartphones/tablets.

Step

1st

Action Description

Start the ekey home app.

Display

- -

2nd Follow the instructions on the display

Couple the smartphone/tablet with the finger scanner using the default admin coupling code

9999 .

Status LED lights up blue, left-hand function LED lights up orange.

The coupling between the finger scanner and the smartphone or tablet is established. The system is in normal mode. You can now start programming and managing the finger scan access control system via the

ekey home app.

NOTICE

The intuitive ekey home app is now all you need for the administration of your Bluetooth finger scanner. Tap the required functions in the app and follow the instructions on the display.

38│en

The Bluetooth functionality can be disabled (default setting: enabled).

Step Instruction

1st Start the ekey home app.

2nd Select

ADMINISTRATION

.

3rd Select

SYSTEM STATUS

.

Deactivating

Bluetooth

4th

Under

BLUETOOTH SETTINGS

, enable the setting Disable BT on finger scanner after 15 minutes of idleness.

This setting disables Bluetooth on the finger scanner after 15 minutes if one of the following situations arises:

□ No smartphone/tablet is connected

□ No finger is enrolled

You can re-enable Bluetooth by entering the security code in the control panel.

You can couple additional smartphones/tablets with the Bluetooth finger scanner using the 6-digit admin/user coupling code you have chosen.

Coupling additional smartphones/ tablets

See Storing a user coupling code, page 40.

Step

1st

Action Description

Start the ekey home app.

Display

- -

2nd Follow the instructions on the display

Couple the smartphone/tablet with the finger scanner using the

6-digit admin/user coupling code you have chosen.

Status LED lights up blue, left-hand function LED lights up orange.

The coupling between the finger scanner and the smartphone or tablet is established. You can now start programming and managing the finger scan access control system via the ekey home app. en│39

Managing multiple

Bluetooth finger scanners

Storing a user coupling code

The ekey home app allows you to manage multiple Bluetooth finger scanners. To switch between two finger scanners, you must reset the coupling between the finger scanner and the smartphone/tablet.

NOTICE

When you reset the coupling, any relay names and user images that have been stored will be deleted. User names and rights will remain stored on the finger scanner.

Step Instruction

1st Start the ekey home app.

2nd Select

ADMINISTRATION

.

3rd Select

RESET COUPLING

.

4th Confirm that you wish to carry out the reset by selecting

Continue .

The coupling between the finger scanner and the smartphone/tablet has been reset. You can now couple another Bluetooth finger scanner.

See Coupling additional smartphones/ tablets, page 39.

The option is available to store a user coupling code. This can be passed on to a person of your choosing, who can then use it to perform the following actions with their smartphone/tablet:

□ Open a door

□ Enable/disable the app security code

□ Change the app security code

□ Reset the coupling between the finger scanner and their smartphone/tablet

Step Instruction

1st Start the ekey home app.

2nd Select

ADMINISTRATION

.

3rd Select

CHANGE SECURITY CODES

.

4th Enter the required user coupling code in the corresponding field.

5th Confirm by selecting Change .

The user coupling code was stored.

40│en

If you have forgotten the app security code, you can use the app to reset the coupling between the finger scanner and the smartphone/tablet.

When this reset is performed, the app security code is also reset to the default value of 9999 .

Step Instruction

1st Start the ekey home app.

2nd Enter an incorrect app security code.

3rd

Confirm by selecting Next .

4th Select

RESET COUPLING

.

5th Confirm that you wish to carry out the reset by selecting

Continue .

The coupling between the finger scanner and the smartphone/tablet has been reset and the app security code set to 9999 . You can now recouple the Bluetooth finger scanner.

See Coupling additional smartphones/ tablets, page 39.

If you have lost your smartphone/tablet, you can use a second smartphone/tablet to change the admin/user coupling code. This new code will stop any connections being established using the lost smartphone/tablet.

Step Instruction

1st Start the ekey home app on the second smartphone/tablet.

2nd Couple the second smartphone/tablet with the finger scanner.

3rd Select

ADMINISTRATION

.

4th Select

CHANGE SECURITY CODES

.

5th Enter a new 6-digit admin/user coupling code.

6th Confirm by selecting Change .

The admin/user coupling code in the system has now been changed. This means that the lost smartphone/tablet is no longer able to establish a connection to the Bluetooth finger scanner. Your system is protected against access by unauthorized persons once again.

Resetting the app security code

Protecting the system in the event that the smartphone/ tablet is lost

en│41

Opening a door

The primary purpose of the product is to open doors. This can be carried out using the finger scanner, an RFID transponder, the app, or the digital input. The system is in normal mode.

Using the finger scanner

Step

1st

Action Description

Swipe a stored finger over the sensor.

Display

Status LED lights up green.

Status LED lights up red.

2nd No action required.

The finger was not recognized. Repeat step

1.

-

The door opens.

-

Status LED lights up blue.

The system is in normal mode.

Using an RFID transponder

NOTICE

You can only open a door using an RFID transponder for finger scanners with an RFID function.

Step

1st

Action Description

Hold a stored RFID transponder up to the finger swipe area of the finger scanner.

Display

Status LED lights up green. Short beep.

Status LED lights up red.

Long beep.

2nd

No action required.

The RFID transponder was not recognized.

Repeat step 1 with a valid RFID transponder.

The door opens.

- -

Status LED lights up blue.

The system is in normal mode.

42│en

Using the app

Step Instruction

1st Start the ekey home app.

2nd Connect to the Bluetooth finger scanner.

3rd Select

ACCESSES

.

4th

Slide the slider of the door to be opened to the right.

5th The door opens.

The system is in normal mode.

Using the digital input (request-to-exit button)

You can also open the door using the digital input on the ekey home CP

IN. The relay switches for the defined relay switching time. If the digital input is enabled for longer than the defined relay switching time, the relay switches for as long as the digital input is enabled.

Usage of the code pad with shortcuts

The devices must have been commissioned before you start your system administration.

See Commissioning devices and establishing normal mode, page 15.

The system is in normal mode. The keypad is used for programming the system.

Entering the admin code grants you access to the Admin menu. The

Admin menu is used to configure the system. The default admin code is

9999 .

ATTENTION

Change the default admin code immediately after commissioning.

If you do not make this change, you risk making it easier for unauthorized persons to access not only your Admin menu, but also your home.

Choose a new admin code and keep it secret.

See Changing the admin code, page 44.

Entering the admin code

en│43

Changing the admin code

The system is in normal mode.

Step Action Description

1st Press

to start the process of entering the admin code.

2nd Enter the admin code on the keypad.

Display

-

3rd Press

.

Status LED lights up yellow on the left.

-

Status LED lights up green on the left.

Status LEDs light up red.

- The admin code was not recognized.

Repeat the procedure beginning at step 1.

The system is in the Admin menu.

-

NOTICE

The system automatically switches back to normal mode if you do not press a button within 10 s.

This function allows you to change the existing admin code. The admin code may contain between 4 and 8 digits. The digits cannot all be the same; at least one of them must be different.

The admin code can be changed via the Admin menu. To get to the Admin menu, enter the admin code.

See Entering the admin code, page 43.

The system is in the Admin menu.

Step

1st

Action Description

Press 3 .

Display

2nd

3rd

Press

.

Enter the old admin code on the keypad.

-

Status LED lights up green on the left.

Status LEDs light up green on the left and yellow on the right.

-

44│en

Step

4th

Action Description

Press

.

Display

Status LEDs light up yellow.

Status LEDs light up red.

-

5th

The old admin code was not recognized.

Enter the admin code from the beginning again.

-

Enter the new admin code on the keypad.

- -

6th

Press

.

Status LEDs light up yellow on the left and green on the right.

Status LEDs light up red.

The desired admin code has already been assigned as a user code. Enter the admin code from the beginning again.

-

7th Enter the new admin code again on the keypad.

Press

.

- -

8th Status LEDs light up green.

-

-

Status LEDs light up red.

The two entries do not match. The new admin code was not saved. Enter the admin code from the beginning again.

-

-

9th No action required.

-

The new admin code is saved. The system is in normal mode.

Status LEDs are off.

en│45

Setting the automatic backillumination

The brightness threshold for switching on the automatic back-illumination can be set using percentage values. By default, the brightness threshold is set to 10%. Enter the required percentage value:

□ 0 = automatic back-illumination off

□ 1 to 100 = brightness threshold settings between highly insensitive and highly sensitive.

NOTICE

Alter the setting gradually to approach the required brightness threshold.

The system responds very sensitively.

The automatic back-illumination is set via the Admin menu. To get to the

Admin menu, enter the admin code.

See Entering the admin code, page 43.

The system is in the Admin menu.

Step

1st

Action Description

Press 5 , 1 , and the value of the required brightness threshold.

E.g.: 7 , 0 for 70%.

Display

Status LED lights up green on the left.

2nd Press

. Status LEDs light up green.

Status LEDs light up red.

- Something has been entered incorrectly.

The brightness threshold was not changed. Enter the admin code from the beginning again.

-

3rd No action required.

- Status LEDs are off.

The automatic back-illumination was set. The system is in normal mode.

46│en

The brightness of the back-illumination can be set using 4 predefined modes. By default, the back-illumination is set to 100%. Enter the number of the required illumination:

□ 0 = back-illumination off

□ 1 = back-illumination at 33%

□ 2 = back-illumination at 66%

□ 3 = back-illumination at 100%

The back-illumination brightness is set via the Admin menu. To get to the

Admin menu, enter the admin code.

See Entering the admin code, page 43.

The system is in the Admin menu.

Step

1st

Action Description

Press 5 , 2 , and the number of the required mode. E.g.: 1 for 33%.

Display

Status LED lights up green on the left.

2nd Press

. Status LEDs light up green.

Status LEDs light up red.

- Something has been entered incorrectly.

The brightness was not changed. Enter the admin code from the beginning again.

-

3rd No action required.

- Status LEDs are off.

The back-illumination brightness was set. The system is in normal mode.

Setting the brightness of the backillumination

en│47

Setting the signaling that indicates when a button has been pressed

4 predefined modes can be used to set the acoustic and optical signaling that indicates when a button has been pressed. By default, the acoustic and optical signals indicating that a button has been pressed are enabled.

Enter the number of the required mode:

□ 0 = acoustic and optical signals disabled

□ 1 = acoustic signals on and optical signals disabled

□ 2 = acoustic signals off and optical signals enabled

□ 3 = acoustic and optical signals enabled

The signaling to indicate that a button has been pressed is set via the

Admin menu. To get to the Admin menu, enter the admin code.

See Entering the admin code, page 43.

The system is in the Admin menu.

Step

1st

Action Description

Press 5 , 4 , and the number of the required mode. E.g.: 0 for acoustic and optical signals disabled.

Display

Status LED lights up green on the left.

2nd Press

. Status LEDs light up green.

Status LEDs light up red.

- Something has been entered incorrectly.

The signaling was not changed. Enter the admin code from the beginning again.

-

3rd No action required.

- Status LEDs are off.

The optical and acoustic signaling to indicate that a button has been pressed was set. The system is in normal mode.

48│en

The acoustic signal for opening can be enabled or disabled. By default, the acoustic signal is enabled. Enter the number of the required status:

□ 0 for disabled

□ 1 for enabled

The acoustic signal for opening is set via the Admin menu. To get to the

Admin menu, enter the admin code.

See Entering the admin code, page 43.

The system is in the Admin menu.

Step

1st

Action Description

Press 5 , 5 , and the number of the required status.

Display

Status LED lights up green on the left.

2nd Press

. Status LEDs light up green.

Status LEDs light up red.

- Something has been entered incorrectly.

The signaling was not changed. Enter the admin code from the beginning again.

-

3rd No action required.

- Status LEDs are off.

The acoustic signal for opening was set. The system is in normal mode.

Setting an acoustic signal for opening

en│49

Storing a user code

The system enables a maximum of 99 user codes to be enrolled.

A user code is any pin code which is used for triggering an action on the control panel, e.g., opening a door. The user code may contain between 4 and 8 digits. The digits cannot all be the same; at least one of them must be different.

NOTICE

To ensure the access control system remains secure, please remember the following when selecting a user code:

□ Use long user codes

□ Use only numbers if possible

□ Do not use trivial codes

User codes are stored via the control panel main menu. To get to the main menu, enter the security code.

See Entering the security code, page 21.

The system displays the main menu.

Step

1st

Action Description

Press < or > is displayed.

until Eu

2nd Press OK .

Display

3rd Press < or > to select the user number. If the user has already stored a user code, a point lights up on the right.

4th

Press OK .

5th

Press < or > to select the relay. od = double relay

(relay 1 + 2). Relay selection is available on control panels with more than one relay.

50│en

Step

6th

Action Description

Press OK .

Display

Status LEDs light up green.

7th Enter the required user code on the keypad.

Press

.

-

8th Status LED lights up green on the right.

Status LEDs light up red.

-

9th

The user code is already present. Start again at step 1.

-

Enter the required user code again on the keypad.

-

Press

.

-

10th

The two entries do not match. The user code was not stored. Start again at step 1.

-

11th No action required.

-

The user code is stored. The system is in normal mode.

Status LEDs light up green.

Status LEDs light up red.

-

Status LEDs are off.

en│51

Opening a door

The primary purpose of the product is to open doors. This can be carried out using the code pad or even – in the case of the ekey home control

panel integra – using the digital input. The system is in normal mode.

Using the code pad

Step

1st

Action Description

Enter a stored user code on the keypad.

Press

.

Display

- -

2nd Status LEDs light up green.

Status LEDs light up red.

- The user code was not recognized. Repeat the procedure beginning at step 1.

-

3rd No action required.

The door opens. Status LEDs are off.

The system is in normal mode.

NOTICE

If the code is entered incorrectly three times, there will be a 1-minute lock. If the code is entered incorrectly another 3 times, there will be a 15minute lock. Each additional incorrect entry will result in a further 15minute lock. You can unlock the code pad again by entering the admin code twice instead of the user code.

Using the digital input (request-to-exit button)

You can also open the door using the digital input on the

ekey home CP

IN. The relay switches for the defined relay switching time. If the digital input is enabled for longer than the defined relay switching time, the relay switches for as long as the digital input is enabled.

52│en

You can only delete individual users. Once you have deleted a user, the user code saved for this user is also deleted.

Users are deleted via the main menu. To get to the main menu, enter the security code.

See Entering the security code, page 21.

The system displays the main menu.

Step Action Description

1st

Press < or > is displayed.

until du

2nd

Press OK .

3rd

Press < or > to select the user number. E.g.:

3 .

Display

4th

Press OK .

The user has been deleted. The system is in normal mode.

Deleting the user code

en│53

Performing demo mode

Demo mode makes it possible to attract the attention of visitors to trade fairs and in exhibition halls by means of code pad LEDs lighting up and flashing, constant switching of the control panel display, and relays switching.

Demo mode is executed via the control panel main menu. To get to the main menu, enter the security code.

See Entering the security code, page 21.

The system displays the main menu.

Step Action Description

1st

Press < or > until dE is displayed.

2nd

Press OK .

3rd

Press < or > to select the desired demo variant: dL = demo LEDs – the LEDs light up and flash, and the control panel display switches constantly dr = demo relays – the LEDs light up and flash, the control panel display switches constantly, and the relays switch.

E.g.: dr .

Display

4th

Press OK . The selected demo variant starts.

5th

Press ESC twice to terminate demo mode and return to the main menu.

Demo mode has been executed. The system displays the main menu.

1 point flashes on the left.

54│en

Trade fair mode simplifies the user storing process for demo purposes.

NOTICE

□ Operation is not possible once trade fair mode is enabled

□ The system automatically returns to trade fair mode after a power failure

□ Trade fair mode only switches relay 1

Trade fair mode is executed via the main menu. To get to the main menu, enter the security code.

See Entering the security code, page 21.

The system displays the main menu.

Step

1st

Action Description

Press < or > is displayed.

until MM

2nd

Press OK .

3rd

Press OK .

4th No action required.

Trade fair mode has been enabled.

5th Enter a 4-digit user code on the keypad.

Display

6th Press

.

Status LEDs light up yellow.

-

Status LEDs light up green.

Status LEDs light up red.

-

7th No action required.

The user code was entered incorrectly.

Repeat the procedure beginning at step 1.

- Status LEDs are off.

8th

Press ESC to terminate trade fair mode and return to the main menu.

Performing trade fair mode

en│55

56│en

Trade fair mode has been set and terminated again. The user codes stored while in trade fair mode have been deleted. The system displays the main menu.

Reset the system to default settings

You can reset the system to its default settings via the control panel, the code pad, or the app (Bluetooth finger scanners only). Use whichever device is most easily accessible.

NOTICE

□ All fingers, user codes, and RFID transponders are permanently deleted. The admin code is reset to its default setting of 9999 using the code pad.

□ The security code is set to 99.

□ The control panel and registration unit are no longer coupled together.

□ The relay switching times are set to 3 s.

□ The LED intensity of the finger scanner is reset to 1 (LED dimmed).

□ For a Bluetooth finger scanner, the admin coupling code is reset to the default setting of 9999.

□ The brightness threshold of the automatic back-illumination is reset to 10% and the brightness value of the back-illumination to 100% using the code pad.

□ The acoustic and optical signaling that indicates when a button has been pressed, and the acoustic signal for door opening, are both enabled again using the code pad.

Resetting to default settings permanently deletes all rights and resets the system settings to their defaults. Your system is then in the condition in which it was delivered to you once more.

Settings are reset to the default via the main menu. To get to the main menu, enter the security code.

See Entering the security code, page 21.

The system displays the main menu.

Step Action Description

1st

Press < or > until rr is displayed.

2nd

Press OK .

3rd

Press < or > to select the first digit of your security code. E.g.: 9 .

Display

4th Press OK .

5th

6th

Press < or > to select the second digit of your security code. E.g.: 9 .

Press OK . 2 points light up.

The system has been reset to its default settings. You can now recommission the system.

Via the control panel

See step 3 of Commissioning devices and establishing normal mode, page 15.

en│57

Via the code pad

The process of resetting to the default settings is initiated via the Admin menu of the code pad. To get to the Admin menu, enter the admin code.

See Entering the admin code, page 43.

The system is in the Admin menu.

Step Action Description

1st

Press 4 .

Display

2nd Press

.

Status LED lights up green on the left.

Status LEDs light up red.

3rd Enter the admin code on the keypad.

- -

4th Press

. Status LEDs are off.

Status LEDs light up red.

- The admin code was not recognized. The system was not reset.

Enter the admin code from the beginning again.

-

5th No action required.

- Status LEDs flash yellow alternately.

The system has been reset to its default settings. You can now recommission the system.

See step 3 of Commissioning devices and establishing normal mode, page 15.

58│en

The process of resetting to the default settings is initiated via the app.

NOTICE

The app can only be used for resetting in the case of Bluetooth finger scanners.

Step Instruction

1st Start the ekey home app.

2nd Connect to the Bluetooth finger scanner.

3rd Select

ADMINISTRATION

.

4th Select

RESET SYSTEM

.

5th Confirm that you wish to carry out the reset by selecting

Continue .

The system has been reset to its default settings. You can now recommission the system.

See step 3 of Commissioning devices and establishing normal mode, page 15.

Updating the software

We are working to improve our products and add new functions all the time. Correspondingly, updates are made available for the registration unit and control panel software. More information about this can be obtained from your dealer.

Via the app

en│59

Control panel

Error displays and troubleshooting

Display Meaning Remedy

No data connection to the registration unit.

Check the wiring and the power supply.

99 fingers, pin codes, or

RFID transponders have already been stored. The memory is full.

Delete some fingers.

An incorrect security code has been entered 3 times. The system is locked for 30 minutes.

After 30 minutes, enter the correct security code.

The 30-minute lock will only count down if the power supply and data connection are present throughout.

Incorrect device coupling Perform the coupling process again. One of the devices has been tampered with.

Need update The control panel requires a firmware update.

If these remedies do not solve the problem, contact your dealer. If the system has to be returned to ekey biometric systems GmbH, ensure that it is correctly packaged. Improper packaging can lead to the warranty being voided.

60│en

Display

Status LED lights up red.

Meaning

The finger or RFID transponder was not recognized.

Remedy

Swipe the finger over the sensor again.

Check that your RFID transponder is the valid one.

Store a minimum of one finger or RFID transponder.

Status LED instantly lights up red.

No fingers or RFID transponders are stored.

Status LED flashes orange.

Status LED flashes red/green.

No bus connection to the control panel.

The sensor of the finger scanner without RFID function is soiled or broken.

Check the wiring or commission the device.

Clean the sensor.

Status LED lights up blue, lefthand function

LED flashes red/green.

The sensor of the finger scanner with RFID function is soiled or broken, but the RFID function still works.

Clean the sensor.

If these remedies do not solve the problem, contact your dealer. If the system has to be returned to ekey biometric systems GmbH, ensure that it is correctly packaged. Improper packaging can lead to the warranty being voided.

Finger scanner

en│61

Code pad

Display

Status

LEDs light up red.

Status

LEDs light up red.

Status

LEDs light up red.

Meaning

The user code was not recognized.

Remedy

Enter the user code on the keypad again.

The numbers in the desired user code are all the same. E.g.:

1111, 3333.

Enter a new user code containing at least one number that is different from the others. E.g.:

1115, 3733.

The desired user code is too short or too long.

E.g.: 321, 987654321.

Enter a new user code with a minimum of 4 digits and a maximum of

8 digits. E.g.: 4321,

87654321.

Status

LEDs light up red.

An error occurred when entering menu items or values.

Carefully read the description of the required function again.

Status LED lights up red on the right.

An incorrect user code has been entered 3 times. 1-minute or 15minute system lock.

After the 1-minute or 15minute lock, enter a correct user code. The 1minute or 15-minute lock will only count down if the power supply and data connection are present throughout.

Status

LEDs flash yellow alternately.

No bus connection to the control panel.

Check the wiring or commission the device.

If these remedies do not solve the problem, contact your dealer. If the system has to be returned to ekey biometric systems GmbH, ensure that it is correctly packaged. Improper packaging can lead to the warranty being voided.

62│en

Maintenance

The system is largely maintenance-free.

The sensor surface of the finger scanner is essentially self-cleaning due to repeated use (swiping of fingers). However, if the finger scanner becomes soiled, clean it with a damp (not wet), non-abrasive cloth. Q-tips, microfiber cloths, and glasses-cleaning cloths are suitable for this purpose. Cotton-containing materials, paper towels, tissues, kitchen sponges, damp dish towels, and kitchen roll are not suitable. Use clean water without adding detergent. Treat the sensor surface with care.

For safety, clean fingerprints and dirt off the code pad from time to time using a damp (not wet), non-abrasive cloth. Use clean water without adding detergent.

Disposal

Pursuant to Directive 2002/96/EC of the European Parliament and Council of January 27, 2003 on the sale, return, and environmentally friendly disposal of waste electrical and electronic equipment (WEEE), electrical and electronic equipment supplied after August 13, 2005 is to be recycled.

It must not be disposed of with household waste. As disposal regulations within the EU can differ from country to country, please contact your dealer for further information as necessary.

Declaration of conformity

ekey biometric systems GmbH hereby declares that the product conforms to the relevant European Union directives. The declarations of conformity for the individual products can be downloaded from http://www.ekey.net/downloads .

Copyright

Copyright © 2016 ekey biometric systems GmbH.

All content, artwork, and any ideas contained in these operating instructions are subject to applicable copyright laws. Any transmission, relinquishment, or transfer of this content or parts thereof to any third party requires the prior written consent of ekey biometric systems GmbH.

Translation of the original documentation. en│63

Austria

ekey biometric systems GmbH

Lunzerstraße 89, A-4030 Linz

Tel.: +43 732 890 500 2500 [email protected]

Switzerland & Liechtenstein

ekey biometric systems Est.

Landstrasse 79, FL-9490 Vaduz

Tel.: +41 71 560 54 80 [email protected]

Italy

ekey biometric systems Srl.

Via del Vigneto, 35/A, I-39100 Bolzano

Tel.: +39 0471 922 712 [email protected]

www.ekey.net

Germany

ekey biometric systems Deutschland GmbH

Liebigstraße 18, D-61130 Nidderau

Tel.: +49 6187 906 960 [email protected]

Eastern Adriatic region

ekey biometric systems d.o.o.

Vodovodna cesta 99, SLO-1000 Ljubljana

Tel.: +386 1 530 94 95 [email protected]

ID 171/497/0/339: Version 3, 09.12.2015

Made in Austria

advertisement

Key Features

  • Fingerprint authentication
  • PIN code authentication
  • Relay switching times
  • LED intensity
  • User profiles
  • Troubleshooting tips
  • Maintenance instructions
  • Digital input for request-to-exit button, feedback and block for relay 1

Frequently Answers and Questions

What is the default security code?
The default security code is 99. You should change this immediately after commissioning to prevent unauthorized access.
How do I store a fingerprint?
You can store up to 99 fingerprints in the system. Instructions for storing fingerprints can be found on page 26 of the manual.
How do I open a door using the finger scanner?
Simply swipe a stored finger over the sensor on the finger scanner and the door will open.
What is the difference between the ekey home CP WM and ekey home CP IN control panels?
The ekey home CP WM control panel is wall-mounted, while the ekey home CP IN control panel can be integrated into a wall. The ekey home CP IN control panel also features a digital input for additional functionality.
What is trade fair mode?
Trade fair mode simplifies the user storing process for demo purposes. It allows visitors to quickly and easily store their fingerprints to test the product.
How do I reset the system to default settings?
You can reset the system to default settings via the control panel, code pad, or app. Instructions can be found on page 56 of the manual.

Related manuals

Download PDF

advertisement

Table of contents