Transmission Format Between DACT and Receiver Ademco Contact ID Format Event Code Descriptions
APPENDIX A
Ademco Contact ID Format
Event Code Descriptions
This appendix describes the various Event Codes and their messages which are available for the
Ademco Contact ID Format.
A.1 Transmission Format Between DACT and Receiver
The transmission string for the Ademco Contact ID Format is as follows:
SSSS 18 QXYZ GG CCC where
SSSS = Four digit Subscriber ID Account Code
18
Q
= Identifies transmission as Contact ID to the receiver at the Central Station
= Event Qualifier where 1 = New Event and 3 = New Restore
XYZ = Event code
GG = Group number
CCC = Zone number
Notes:
1. 18, which is used in the reporting structure to identify the transmission as Contact ID, is not printed out in the alarm and trouble report.
2. GG Group Number is fixed at '00' and cannot be changed.
3. CCC for Zone Number is transmitted as ‘001’ for zone 1 up to ‘010’ for zone 10
A.2 Ademco Contact ID Typical Printout
A typical printout from a Central Station receiver (such as the Ademco 685) of alarm and trouble reports in the Ademco Contact ID Reporting Structure follows:
Time
11:28
11:28
11:28
11:28
11:28
11:28
11:28
11:28
11:28
11:28
Date
03/25
03/25
03/25
03/25
03/25
03/25
03/25
03/25
03/25
03/25
Rcvr/Line ID
11
11
11
11
11
11
11
11
11
11
SSSS
7777
7777
7777
7777
7777
7777
7777
7777
7777
7777
QXYZ
E110
E111
E380
E570
R110
R111
R380
R570
E158
E151
GG
00
00
00
00
00
00
00
00
00
00
CCCC
C001 - general fire alarm on zone one
C002 - smoke detector alarm on zone two
C003 - fault on zone three
C009 - Zone nine disabled
C001 - Zone one alarm restored
C002 - smoke detector zone two restored
C003 - zone three fault restored
C009 - zone nine reenabled
C006 - high temperature, zone six
C007 - gas detected, zone seven
Notes:
1. 11 is an example of a Receiver/Line Card, showing which receiver and line card the message was transmitted to.
2. Q, which is the Event Qualifier for the reporting structure, is printed out in the report as an E for New Event or R for New Restore.
MS-5UD/MS-10UD Series PN 52626:A1 5/11/2007 127
Ademco Contact ID Format Event Code Descriptions Ademco Contact ID Typical Printout
EVENT CODE CLASSIFICATIONS
128
100
ALARMS
Medical Fire
Panic Burglary General 24
Hour
200
SUPERVISORY
300
TROUBLES
Fire
System Sounder/
Relay System
Peripheral Communication Protective
Loop Sensor
400
OPEN/CLOSE
REMOTE ACCESS
Open/Close Remote
Access Access Control
500
DISABLES/
BYPASSES
System Sounder/
Relay System
Peripheral Communication
Test
600
TEST/
MISC.
EVENT
Medical Alarms - 100
100 Medical
101 Pendant transmitter
102 Fail to report in
Fire Alarms - 110
110 Fire Alarm
111 Smoke
112 Combustion
113 Waterflow
114 Heat
115 Pull station
116 Duct
117 Flame
118 Near Alarm
Panic Alarms - 120
120 Panic Alarm
121 Duress
122 Silent
123 Audible
Burglar Alarms - 130
130 Burglary
131 Perimeter
132 Interior
133 24-Hour
134 Entry/Exit
135 Day/Night
136 Outdoor
137 Tamper
138 Near Alarm
General Alarms - 140
140 General Alarm
141 Polling loop open
142 Polling loop short
143 Expansion module failure
144 Sensor tamper
145 Expansion module tamper
MESSAGE
EMERG - Personal Emergency - #
EMERG - Personal Emergency - #
EMERG - Fail to Check-in - #
FIRE - Fire Alarm - #
FIRE - Smoke Detector - #
FIRE - Combustion - #
FIRE - Waterflow - #
FIRE - Heat Sensor - #
FIRE - Pull Station - #
FIRE - Duct Sensor - #
FIRE - Flame Sensor - #
FIRE - Near Alarm - #
PANIC - Panic - #
PANIC - Duress
PANIC - Silent Panic - #
PANIC - Audible Panic - #
BURG - Burglary - #
BURG - Perimeter - #
BURG - Interior - #
BURG - 24-Hour - #
BURG - Entry/Exit - #
BURG - Day/Night - #
BURG - Outdoor - #
BURG - Tamper - #
BURG - Near Alarm - #
ALARM - General Alarm - #
ALARM - Polling Loop Open - #
ALARM - Polling Loop Short - #
ALARM - Exp. Module Fail - #
ALARM - Sensor Tamper - #
ALARM - Exp. Module Tamper - #
MS-5UD/MS-10UD Series PN 52626:A1 5/11/2007
Ademco Contact ID Typical Printout Ademco Contact ID Format Event Code Descriptions
EVENT
24 Hour Non-Burglary - 150 and 160
MESSAGE
150 24-Hour Non-Burg
151 Gas detected
ALARM - 24-Hr. Non-Burg - #
ALARM - Gas Detected - #
152 Refrigeration
153 Loss of heat
154 Water leakage
155 Foil break
ALARM - Refrigeration - #
ALARM - Heating System - #
ALARM - Water Leakage - #
ALARM - Foil Break - #
156 Day trouble
157 Low bottled gas level
158 High temp
159 Low temp
161 Loss of air flow
ALARM - Day Zone - #
ALARM - Low Gas Level - #
ALARM - High Temperature - #
ALARM - Low Temperature - #
ALARM - Air Flow - #
Fire Supervisory - 200 and 210
200 Fire supervisory
201 Low water pressure
202 Low CO2
203 Gate valve sensor
204 Low water level
205 Pump activated
206 Pump failure
SUPER. - Fire Supervisory - #
SUPER. - Low Water Pressure - #
SUPER. - Low CO2
SUPER. - Gate Valve - #
SUPER. - Low Water Level - #
SUPER. - Pump Activation - #
SUPER. - Pump Failure - #
System Troubles - 300 and 310
300 System trouble
301 AC loss
302 Low system battery
303 RAM checksum bad
304 ROM checksum bad
305 System reset
306 Panel program changed
307 Self-test failure
308 System shutdown
309 Battery test failure
310 Ground fault
311 No battery
TROUBLE - System Trouble
TROUBLE - AC Power
TROUBLE - System Low Battery
TROUBLE - Bad RAM Checksum (restore not applicable)
TROUBLE - Bad ROM Checksum (restore not applicable)
TROUBLE - System Reset (restore not applicable)
TROUBLE - Programming Changed (restore not applicable)
TROUBLE - Self Test Failure
TROUBLE - System Shutdown
TROUBLE - Battery Test Failure
TROUBLE - Ground Fault - #
TROUBLE - No Battery
Sounder/Relay Troubles - 320
320 Sounder/Relay
321 Bell 1
322 Bell 2
323 Alarm relay
324 Trouble relay
325 Reversing
326 Bell 3
327 Bell 4
TROUBLE - Sounder Relay - #
TROUBLE - Bell/Siren #1
TROUBLE - Bell/Siren #2
TROUBLE - Alarm Relay
TROUBLE - Trouble Relay
TROUBLE - Reversing Relay
TROUBLE - Bell/Siren #3
TROUBLE - Bell/Siren #4
System Peripheral Troubles - 330 and 340
330 System peripheral TROUBLE - Sys. Peripheral - #
331 Polling loop open
332 Polling loop short
TROUBLE - Polling Loop Open
TROUBLE - Polling Loop Short
333 Expansion module failure
334 Repeater failure
335 Local printer paper out
336 Local printer failure
TROUBLE - Exp. Module Fail - #
TROUBLE - Repeater Failure - #
TROUBLE - Printer Paper Out
TROUBLE - Local Printer
MS-5UD/MS-10UD Series PN 52626:A1 5/11/2007 129
Ademco Contact ID Format Event Code Descriptions Ademco Contact ID Typical Printout
EVENT MESSAGE
Communication Troubles - 350 and 360
350 Communication
351 Telco 1 fault
TROUBLE - Communication Trouble
TROUBLE - Phone Line #1
352 Telco 2 fault TROUBLE - Phone Line #2
353 Long range radio xmitter fault TROUBLE - Radio Transmitter
354 Fail to communicate
355 Loss of radio supervision
356 Loss of central polling
TROUBLE - Fail to Communicate
TROUBLE - Radio Supervision
TROUBLE - Central Radio Polling
Protection Loop Troubles - 370
370 Protection loop
371 Protection loop open
372 Protection loop short
373 Fire Trouble
TROUBLE - Protection Loop - #
TROUBLE - Protection Loop Open - #
TROUBLE - Protection Loop Short - #
TROUBLE - Fire Loop - #
Sensor Troubles - 380
380 Sensor trouble
381 Loss of supervision - RF
382 Loss of supervision - RPM
383 Sensor tamper
384 RF transmitter low battery
Open/Close - 400
400 Open/Close
401 Open/Close by user
402 Group Open/Close
403 Automatic Open/Close
404 Late Open/Close
405 Deferred Open/Close
406 Cancel
407 Remote arm/disarm
408 Quick arm
409 Keyswitch Open/Close
Remote Access - 410
411 Callback request made
412 Success - download/access
413 Unsuccessful access
414 System shutdown
415 Dialer shutdown
416 Success - upload/access
Access Control - 420
421 Access denied
422 Access report by user
System Disables - 500 and 510
TROUBLE - Sensor Trouble - #
TROUBLE - RF Sensor Supervision - #
TROUBLE - RPM Sensor Supervision - #
TROUBLE - Sensor Tamper - #
TROUBLE - RF Sensor Batt. - #
OPENING
OPENING - User #
OPENING - Group User # CLOSING - Group User #
OPENING - Automatic CLOSING - Automatic
OPENING - Late
Opening not used
OPENING - Cancel
OPENING - Remote
CLOSING
CLOSING - User #
CLOSING - Late
Closing not used
Closing not used
CLOSING - Remote
Opening not applicable CLOSING - Quick arm
OPENING - Keyswitch CLOSING - Keyswitch
REMOTE - Callback Requested
REMOTE - Successful Access
(restore not applicable)
(restore not applicable)
REMOTE - Unsuccessful Access (restore not applicable)
REMOTE - System Shutdown
REMOTE - Dialer Shutdown
REMOTE - Successful Access (restore not applicable)
ACCESS - Access Denied - User # (restore not used)
ACCESS - Access Gained - User # (restore not used)
130 MS-5UD/MS-10UD Series PN 52626:A1 5/11/2007
Ademco Contact ID Typical Printout Ademco Contact ID Format Event Code Descriptions
EVENT
Sounder/Relay Disables - 520
520 Sounder/Relay disable
521 Bell 1 disable
522 Bell 2 disable
523 Alarm relay disable
524 Trouble relay disable
525 Reversing relay disable
526 Bell 3 disable
527 Bell 4 disable
MESSAGE
DISABLE - Sounder/Relay - #
DISABLE - Bell/Siren - #1
DISABLE - Bell/Siren - #2
DISABLE - Alarm Relay
DISABLE - Trouble Relay
DISABLE - Reversing Relay
DISABLE - Bell/Siren - #3
DISABLE - Bell/Siren - #4
System Peripheral Disables - 530 and 540
Communication Disables - 550 and 560
551 Dialer disabled DISABLE - Dialer Disable
552 Radio transmitter disabled DISABLE - Radio Disable
Bypasses - 570
570 Zone bypass
571 Fire bypass
572 24-Hour zone bypass
573 Burglar bypass
574 Group bypass
Test Misc. - 600
601 Manual trigger test
602 Periodic test report
603 Periodic RF transmission
604 Fire test
605 Status report to follow
606 Listen-in to follow
607 Walk test mode
608 System abnormal test
BYPASS - Zone Bypass - #
BYPASS - Fire Bypass - #
BYPASS - 24-Hour Bypass - #
BYPASS - Burg. Bypass - #
BYPASS - Group Bypass - #
TEST - Manually Triggered
TEST - Periodic (restore not applicable)
TEST - Periodic Radio (restore not applicable)
TEST - Fire Test (restore not used)
STATUS - Status Follows (restore not applicable)
LISTEN - Listen-in Active (restore not applicable)
TEST - Walk Test Mode
TEST - System Abnormal Test
(restore not applicable)
MS-5UD/MS-10UD Series PN 52626:A1 5/11/2007 131