FlexPoint

GX/T

10/100/1000 UTP to 100/1000X

Ethernet Media Converter

User Manual

DESCRIPTION:

The FlexPoint GX/T is a 10/100/1000BASE-T UTP to

1000BASE-X fiber media converter that supports jumbo frames up to 10,240 bytes. The GX/T features Small

Form Pluggable (SFP) transceivers that support both

100BASE-FX and 1000BASE-X for interoperability with

Gigabit and Fast Ethernet fiber equipment.

Both the fiber port and the UTP port support autonegotiation, an IEEE standard which defines how all the communicating devices automatically perform their configuration functions.

The auto-negotiation feature can be disabled on both ports

(for manual configuration) using DIP-switches on the product. This is useful in a situation where the GX/T is connected to a non-negotiating device and the configuration parameters must be set manually.

Page 1

setting the DIP-switch to “Off” causes the unit to advertise no Pause capability. In the manual mode, this DIPswitch determines the Symmetrical Pause behavior.

Loopback “Off/On” DIP-Switch:

Setting this DIP-switch “On” enables loopback on the fiber and UTP ports (see Figure 1).

Link Modes:

See the following table for configuring link modes:

SW9

"LS/LP"

LS

LP

LS

LP

SW10

"RFD/Normal"

Normal

Normal

Result

Enables Link Segment mode (LS).

Enables Link Propagate mode (LP).

RFD

RFD

Enables Remote Fault Detection mode plus

Link Segment mode (RFD+LS).

Enables Remote Fault Detection mode plus

Link Propagation mode (RFD+LP).

NOTE: RFD is only available when the fiber port is operating in manual mode.

REMOTE FAULT

Each port will generate an “IEEE remote_fault indicator” when the incoming signal to the port is lost. When a port is configured for auto-negotiation, it will set the remote fault bit “high” in the AN advertisement when the port detects a loss of incoming signal. See LED Indicators table on page 9 for specifics on how the unit reports the detection of this signal.

When the fiber port is operating in 100BASE-FX, a loss of incoming signal will cause the port to generate a Far-End-

Fault indicator pattern. See LED Indicators table on page

9 for specifics on how the unit reports the detection of this signal.

Connector Type

Fiber Type Distance

SFP

MM

SM

SM

SM

SM

-

220 / 550m

12km

34km

80km

110km

1

ST

-

4706-x

4707-x

-

-

-

SC

-

4700-x

4701-x

4702-x

4703-x

4704-x

SFP

4719-x

-

-

-

-

-

SM 140km 4705-x -

SM-SF

1310/1550

20km

SM-SF

1550/1310

20km

SM-SF

40km

1310/1550

SM-SF

40km

1550/1310

Power Adapter Kits (-x):

-0 = No power adapter included

-

-

-

-

4710-x

4711-x

4712-x

4713-x

Š

Š

Š

Š

-

-

-

-

-1 = 110-120 VAC/60 Hz (US plug)

-2 = 100-240 VAC/50-60 Hz (IEC plug, no power cord)

For other power and fiber configurations, contact the factory.

1 62.5/125µm, 100/140µm multimode fiber up to 220m, 50/125µm

multimode fiber up to 550m. Refer to the fiber cable manufacturer for

multimode distance specifications.

ŠSingle-Fiber converters must be used in pairs. The Tx wavelength

on one end has to match the Rx wavelength on the other.

POWER ADAPTER NOTICE:

1. This product should only be used with Omnitron Supplied

Power Unit model numbers 9113-PS [US] or 9115-PS

[Universal].

2. When used in a standalone configuration, this product must be used with a Listed Direct Plug-In Power Unit marked “Class 2” and rated at 9VDC, 1 Amp.

NOTE: If mounting with a safety ground attachment, use the safety ground screw at the rear of the unit.

NOTE: Remove safety ground screw when installing the module in the 14-Module Chassis or when using

Page 2

UTP MODES

SW3

AN/MAN

SW4

10/100/

1000

1000

SW5

10/100

SW6

FDx/HDx

UTP Mode of Operation

AN

AN

AN

AN

AN

AN

MAN

1000

10-100

10-100

10-100

10-100

1000

NA

NA

100

100

10

10

NA

FDX

HDX

FDX

HDX

FDX

HDX

FDX

Configured for Auto Negotiation.

(1000F, 1000H, 100F, 100H, 10F,

10H)

Configured for Auto Negotiation.

(1000H, 100F, 100H, 10F, 10H)

Configured for Auto Negotiation.

(100F, 100H, 10F, 10H)

Configured for Auto Negotiation.

(100H, 10F, 10H)

Configured for Auto Negotiation.

(10F, 10H)

Configured for Auto Negotiation.

(10H)

Configured for Auto Negotiation.

(1000F)

MAN 1000 NA HDX

When the port is set to 1000, it is always in AN mode.

Configured for Auto Negotiation.

(1000H)

MAN

MAN

MAN

10-100

10-100

10-100

100

100

10

FDX

HDX

FDX

When the port is set to 1000, it is always in AN mode.

Port forced to 100 FDX

Port forced to 100 HDX

Port forced to 10 FDX

MAN 10-100 10 HDX Port forced to 10 HDX

When the module is configured for auto-negotiation, the module will advertise in the order shown in the parenthesis.

Page 7 Page 8

it with the DC-DC Converter (Model # 4384)

WARNING!

Before inserting the Power Adapter, verify that the power on the unit is appropriate for your AC line voltage source.

INSTALLATION PROCEDURE

1.) Configure the appropriate FlexPoint GX/T DIP-Switch settings.

2.) Connect the UTP port via a Category 5 or better cable to a 10BASE-T, 100BASE-TX or 1000BASE-T Ethernet device.

3.) When using fixed fiber port models, connect the appropriate multimode or single-mode fiber cable to the fiber port of the installed module. It is important to ensure that the transmit (Tx) is attached to the receive side of the device at the other end and the receive (Rx) is attached to the transmit side. Single-fiber (SF) media converter models operate in pairs. The Tx wavelength must match the Rx wavelength at the other end and the Rx wavelength must match the Tx wavelength at the other end.

4.) When using a GX/T SFP model, insert the SFP Fiber transceiver into the Port 1 SFP receptacle on the GX/T.

NOTE: The release latch of the SFP Fiber transceiver must be in the closed (up) position before insertion.

LOOPBACK

The FlexPoint GX/T has the capability to provide loopback to aid in installation and maintenance. A DIP-switch is used to enable loopback on the module (see page 7).

Figure 1 shows the module in normal and loopback modes.

Page 3

LED INDICATORS

LED Function

"Legend"

Color

Power / Test

"Power"

F/O AN

"F/O-Auto-Neg"

F/O Speed 100*

"F/O-100"

F/O Speed 1000

"F/O-1000"

UTP Duplex

"UTP-FDX"

UTP AN

"UTP-Auto-Neg"

UTP Speed 100

"UTP-100"

Off State

On / Blinking State

Green

Green

No power

Port configured for manual negotiation

On: Module has power

Blinking: Module in loopback mode

On: Fiber port configured for AN

Blinking: Fiber port configured for

AN but in manual mode

On: Fiber port linked at 100Mbps

Blinking (10Hz): Link activity at

100Mbps

Green

Not connected at

100Mbps

Blinking (1Hz): Signal detected but port unable to establish a link

On: Fiber port linked at 1000Mbps

Blinking (10Hz): Link activity at

1000Mbps

Green

Not connected at

1000Mbps Blinking (1Hz): Signal detected but port unable to establish a link

Pattern Blinking: AN remote Fault bit detected

Green Half-Duplex On: UTP port in Full-Duplex

Green

Port configured for manual negotiation

On: UTP port configured for AN

Blinking: UTP port configured for

AN but in manual mode

Green

Not connected at

100Mbps

On: UTP port linked at 100Mbps

Blinking (10Hz): Link activity

UTP Speed 1000

"UTP-1000"

UTP Speed 10

"UTP-100"

+

"UTP-1000"

Green

Not connected at

1000Mbps

Green

Not connected at

10Mbps

On: UTP port linked at 1000Mbps

Blinking (10Hz): Link activity

On: UTP port linked at 10Mbps

Blinking (10Hz): Link activity

Pattern Blinking: (1Hz): Detecting

"remote_fault" (AN) on UTP port

"UTP Auto-Neg"

+

"UTP-100"

+

"UTP-1000"

*SFP models only

Green -

Blinking (1Hz): Unable to establish

AN link on the UTP port

FlexPoint GX/T

RX

UTP

TX

TX

RX

Fiber

RX

UTP

TX

TX

RX

Fiber

Normal Mode Loopback Mode

Figure 1: Loopback Mode

LINK MODES

In order to accommodate different user needs, the GX/T supports four different link modes (see Fig. 2).

In Link Segment (LS), a port transmits a Link signal independently of any received Link at any other port. For example, the UTP transmits a Link regardless of the fiber receiving a Link [Fig. 2(a) & (b)].

In Link Propagate (LP), a port transmits a Link signal only when receiving a Link at its other port. For example, the

UTP transmits a Link only when receiving a Link at the fiber port [Fig. 2(c)].

In Remote Fault Detection + Link Segment (RFD+LS), the fiber port transmits a Link signal only when receiving a Link at the fiber port. As a result, fiber faults (no Link received at the fiber) are looped-back and can be reported to the network core [Fig. 2(d)].

In Remote Fault Detection + Link Propagate (RFD+LP), the UTP port transmits a Link signal only when receiving a Link at the fiber port. The fiber port transmits a Link signal only when receiving Link signals at both the fiber port and the UTP port. As a result, fiber faults (no Link received at the fiber) are propagated forward and looped back for fault reporting at both the network core and the customer location [Fig. 2(e)].

NOTE: Connecting two converters with both set to RFD mode is not supported and will cause a “deadly embrace” lockup.

Page 4

SPECIFICATIONS

Model Type

Protocols

Frame Size

UTP Cable

Fiber Cables

UTP Connectors

Fiber Connectors

DIP-Switches

LED Displays

Dimensions

Weight

Compliance**

Power

Requirements

Temperature

Humidity

Altitude

MTBF (Hours)

GX/T

IEEE 802.3

10BASE-T, 100BASE-TX, 1000BASE-T, 100BASE-FX,

1000BASE-X

10,240 byte max. frame size

RJ-45, Category 5 and higher

Multimode: 50/125, 62.5/125, 100/140µm

Single-mode: 9/125µm

RJ-45

ST, SC, LC (SFP)

Fiber: Auto-Neg, 1000, 100

UTP: Auto-Neg, 10, 100, 1000, FDX/HDX, Pause En/Dis

Loopback, Link Seg, Link Prop, Remote Fault Det.

Power, Fiber AN, Fiber Speed/Activity, UTP Speed/Activity,

Full/Half-Duplex

W: 3.0" x D: 4.0" x H: 1.0"

6 oz. (without power adapter)

UL, CE, FCC Class A

Barrel

Connector

Molex

Connector

Nominal Voltage:

Voltage Range:

Nominal Power:

Maximum Power:

9VDC

5.0 to 32.0VDC

0.3A @ 9VDC

1A @ 9VDC

0 to 50 o C

5VDC

5.0 to 32.0VDC

0.5A @ 5VDC

0.75A @ 5VDC

5 to 95% (non-condensing)

-100m to 4000m

Module without Power Adapter: 900,000

Module with Power Adapter -1: 250,000

Module with Power Adapter -2: 100,000

Page 9 Page 10

LS LS

Fiber

(a) UTP

Switch 1 Converter A

LS

UTP

Fiber

Converter B Switch 2

LS

(b)

(c)

Switch 1 Converter A

LP

Converter B Switch 2

LP

(d)

Switch 1 Converter A

LP

Switch 1 Converter A

LP

Converter B Switch 2

RFD+LS

Converter B Switch 2

RFD+LP

(e)

Switch 1 Converter A Converter B Switch 2

LED On LED Off

LED Status depends on connected device

Figure 2: Link Modes

Page 5

Warning

The operating description in this Instruction Manual is for use by qualified personnel only. To avoid electrical shock, do not perform any servicing of this unit other than that contained in the operating instructions, unless you are qualified and certified to do so by Omnitron Systems

Technology, Inc.

Caution

All user-required operations can be performed without opening the unit. Never attempt to open or remove the cover or tamper with the unit.

Warranty

This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO

YEARS from the date of shipment. A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment.

TO REGISTER, COMPLETE AND MAIL OR FAX THE

REGISTRATION PORTION OF THIS INSTRUCTION

MANUAL TO THE INDICATED ADDRESS. Or you may register your product on the internet at http://www.omnitron-systems.com. During the warranty period, Omnitron will, at its option, repair or replace a product which is proven to be defective.

For warranty service, the product must be sent to an Omnitron designated facility, at Buyer’s expense. Omnitron will pay the shipping charge to return the product to Buyer’s designated

US address using Omnitron’s standard shipping method.

Limitation of Warranty

The foregoing warranty shall not apply to defects resulting from improper or inadequate use and/or maintenance of the equipment by Buyer, Buyer-supplied equipment, Buyersupplied interfacing, unauthorized modifications or tampering with equipment (including removal of equipment

Page 11

DIP-SWITCHES

F/O Manual/Auto “MAN/AN” DIP-Switch:

Setting this DIP-Switch to P1 Auto-Negotiate “AN” (factory setting) enables the Fiber Port to determine duplex mode automatically. If the connected device cannot provide the proper signal to indicate its own mode of operation, this DIP-Switch should be set to P1 Manual “MAN.” This feature allows connections with legacy devices that do not support auto-negotiation.

NOTE: When the fiber port is in Manual Mode, a link-up may not occur with other devices. Both devices must be set to the same mode (either Manual or Auto-Negotiate) for the link-up to occur.

When set to auto-negotiation, the fiber port will automatically reconfigure to manual mode when an autonegotiation connection cannot be established.

F/O Speed “100/1000” DIP-Switch:

The GX/T supports 100BASE-FX and 1000BASE-X SFPs.

This DIP-switch is used to configure the unit for the speed of SFP used. Setting this DIP-switch to “1000” enables the fiber port is accept 1000BASE-X SFPs. Setting this DIP-switch to “100” enables the fiber port to accept

100BASE-FX SFPs. This DIP-switch is only available on the SFP model.

This DIP-switch is ignored when using Omnitron branded

SFPs. The GX/T automatically configures the fiber port to the correct speed.

UTP Configuration DIP-Switches:

See the UTP Modes table on page 8.

Pause “On/Off” DIP-Switch:

In auto-negotiation mode, setting this DIP-switch to “On” allows the unit to advertise as Symmetrical and

Asymmetrical Pause capability. In auto-negotiation mode,

Page 6

cover by personnel not specifically authorized and certified by Omnitron), or misuse, or operating outside the environmental specification of the product (including but not limited to voltage, ambient temperature, radiation, unusual dust, etc.), or improper site preparation or maintenance.

No other warranty is expressed or implied. Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose.

Exclusive Remedies

The remedies provided herein are the Buyer’s sole and exclusive remedies. Omnitron shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any legal theory.

TECHNICAL SUPPORT:

For help with this product, contact our Tech. Support:

Phone:

Fax:

(949) 250-6510

(949) 250-6514

Address: Omnitron Systems Technology, Inc.

140 Technology Drive, #500

E-mail:

URL:

Irvine, CA 92618 USA [email protected]

http://www.omnitron-systems.com

Form: 040-04700-001A 8/08

Page 12

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement