96M0747 ??? 3. Amplifier Expansion Up to 16 sub units can be connected to each main unit. 1) Remove the expansion protective cover from the main unit. DUAL DIGITAL FIBER SENSOR FS-V22/22G/22R(P)/22X 2) Mount each amplifier to the DIN rail. Instruction Manual 3) Press the two claws of each sub unit to the grooves on the main unit until the claws snap. 4) Mount the end units to the left- and right-hand sides of the whole amplifiers in the method shown in the figure at step 2. 5) Check that the amplifiers are securely sandwiched by the end units. Use a Phillips screwdriver and securely tighten the screws on the end units (i.e., two screws on each end unit). 4. Connecting Fiber Unit 1) Open the dust cover in the direction shown by arrow ➀. 2) Move down the fiber lock lever in the direction shown by arrow ➁. 3) Insert a fiber unit into the fiber insertion holes to a length of the fiber insertion sign (i.e., approximately 14 mm). 4) Move up and return the fiber lock lever in the direction shown by arrow ➃. 1. Safety Precautions WARNING • This product is used to detect targets. Do not apply the product to safety circuits for human protection. • This product is not of explosion-proof construction. Do not use the products in places with flammable gas, liquid, or dust. Fiber insertion sign • This product is a sensor of DC power supply type. Do not apply AC power. The product may explode or burn if 100 VAC or a higher voltage is applied. Note:If a thin fiber unit is used, an adapter provided with the thin fiber unit will be required. Unless the right adapter is connected, the thin fiber unit will not detect targets correctly. Check that all the accessories are ready before use. • Accessories Instruction End units (x2) Expansion Sticker (x1) manual (x1) Slide the unit to the right to remove it. Cable outer dia. Adapter ø1.3 Adapter A Appearance ø1.0 Adapter B • To connect the coaxial reflective type fiber unit to the amplifier, connect the single-core fiber to the transmitter side, and connect the multiplecore fiber to the receiver side. 2. Part Names Transmitter Single-core fiber Fiber lock lever Multi-core fiber Operation indicator* Set button Digital monitor Manual button Receiver • To remove the amplifiers added, take the steps opposite to the mounting procedure. • Put the provided sticker close to the sensor. Preset value (PV) green indicator Note • The FS-V22/22G/22R(P)/22X incorporates a mutual interference prevention function, thus allowing the close mounting of a number of fiber units in the following modes. Current value (CV) red indicator Expansion protective cover Expansion connector Mode button Power mode FINE TURBO SUPER TURBO ULTRA TURBO Number of units connected 4 8 8 8 5. I/O Cricuit Output selector Refer to the following I/O circuit diagram when connecting the unit to peripheral devices. ● FS-V22/22G/22R/22X ● FS-V22RP Cable Dust cover Black 0V 1 (Control output) DC 5 to 40V Overcurrent protection circuit Overcurrent protection circuit Photoelectric sensor main circuit Max. 100mA Load Photoelectric sensor main circuit DC 12 to 24V * The operation indicator of the FS-V22X (infrared model) will not be lit. Black Max. 100mA Load (Control output) DC 5 to 40V 6. Making Sensitivity Settings ● Full Auto Calibration In this mode, the PV will be set to the mean value of the maximum and minimum incident values obtained within a certain period. Use this mode to detect moving workpieces. 1) Press the set button for a minimum of three seconds while the target workpiece is passing the sensing area of the fiber unit. • While the set button is pressed, the sensitivity of the sensor will be set according to the incident values. ● Manua| Calibration In this mode, make manual PV settings. PV The PV value decreases by pressing this side of the manual button. The PV value increases by pressing this side of the manual button. Workpiece ● Positioning Calibration In this mode, a workpiece will be detected when the front edge of the workpiece has reached a preset position. 1) Press the set button for a moment without the workpiece in the sensing area (i.e., in front of the fiber unit). Workpiece The display will 3 s min. flash when the settings are completed. • When the setting is finished, the digital monitor will display the PV in green. The display will be lit when the workpiece is detected. PV (green) 2) Locate the front edge of the workpiece in the sensing area. Then press the set button for a minimum of three seconds. CV (red) Workpiece ● Two-point Calibration In this mode, the PV used will be the mean value of two sensing values obtained with and without a workpiece. 1) Press the set button for a moment without the workpiece in the sensing area (i.e., in front of the fiber unit). Front edge 3 s min. Workpiece The display will flash for a moment when the setting is finished. Then the PV will be displayed. 7. Selecting Output The display will be lit when the workpiece is detected. Either light-ON mode or dark-ON mode is selectable. Press the mode button. 2) Locate the workpiece in the sensing area (i.e., in front of the fiber unit). Then press the set button for a moment. Workpiece The display indicates that the sensor is in dark-ON mode. The CV will be displayed if no buttons are operated for approximately five seconds. The PV will appear when the settings are completed. * If there is extremely little difference in sensitivity between the sensing values, the display will flash on completion of tuning. Press the manual button within five seconds after pressing the mode button . • Take the same steps to set the sensor to light-ON mode again. ● Maximum Sensitivity Setting If the sensing performance of the sensor drops due to dust or dirt, set the sensitivity of the sensor to maximum. 1) Press the set button without a workpiece if the fiber unit is a reflective model. Press the set button with a workpiece if the fiber unit is a through-beam model. In both cases, press the set button for a minimum of three seconds. 8. User-friendly Functions ● Access Mode Selection Two modes are available to the display of values and menu items. EASY Only basic functions are displayed. FULL All available functions are displayed. “Reflective model” “Through-beam model” 3 s min. The display will flash for a moment when the setting is finished. Then the PV will be displayed. Press 3 s min. Select Completion of selection FULL Press 3 s min. • The mode is set to EASY before shipping. * If the sensing distance is insufficient, make sensitivity settings in the sensor in two-point tuning mode. 2 EASY ● Menu Selection (Access Mode: FULL) ● Display Selection (Access Mode: EASY) PV CV Press the mode button 3 s min Access mode selection Press Press Excess gain Press CV • The CV is displayed in percent based on the PV. Normal operation use Power mode selection Output Power status mode status FINE Select • The current value will be displayed if no keys are operated for approximately 30 s. • If the timer function is set, the output status with power mode and the timer mode with set time will be displayed alternately. Press Timer function setting ● Display Selection (Access Mode: FULL) PV Press Select CV Press Press Press Excess gain Output status Other than Power mode status Press CV Power mode , Press Peak excess gain S-APC mode setting Bottom excess gain Press LED bar indicator CV Select Press Peak value Bottom value ● Menu Selection (Access Mode: EASY) Access mode selection Press Power mode selection Press manual button to select Press Timer function setting Press manual button to select Press Normal FINE operation use Used if the sensing TURBO distance is insufficient while the sensor is in fine mode. Used if the sensing SUPER environment is bad TURBO due to dust or other obstacles. Select OFF (for normal operation use) ECO half ECO all Other than Power mode Select Press OFF (for normal operation use) Shift ON Timer OFF (for normal operation use) OFF-delay timer ON-delay timer One-shot timer Shift value adjustment Press Shift value Other than Press OFF (for normal operation use) Rising edge Falling edge Press Power mode Shift function setting Select Press Power save function setting Press the mode button 3 s min Timer adjustment range 1~30ms 1-ms increments 30~50ms 2-ms increments 50~200ms 10-ms increments 200~500ms 50-ms increments * A maximum error of ±10% of the PV. OFF (for normal operation use) Used to detect sensing objects highly precisely under clean environments. Edge detection mode selection Press Timer OFF (for normal operation use) OFF-delay timer ON-delay timer One-shot timer Timer adjustments Other than Power mode , Press Used if the sensing distance is insufficient TURBO while the sensor is in fine mode. Used if the sensing environment is SUPER TURBO bad due to dust or other obstacles. Used if the incident is insufficient while ULTRA TURBO the sensor is in SUPER TURBO mode. Used to detect sensing objects HIGH SPEED moving at high speed. Used to detect delicate differences HIGH RESO- within a short sensing distance. LUTION CV Sensitivity Settings in Edge Detection Mode The sensitivity of the sensor will be set to maximum by pressing the while the sensor is in edge detection mode. Make fine sensitivity adjustments by pressing the . Press to manual button to make timer adjustments * For timer values, refer to the corresponding table under FULL mode. Note: • Press the mode button ( ) for a minimum of three seconds to return to the display of the CV from any menu selection stage. To return to the previous ) of the manual button ( ). display, press the mode button ( ) first, and press the left side ( • When the power mode is set to HIGH RESOLUTION, the S-APC mode will be always turned ON. • When the power mode is set to HIGH SPEED, the S-APC mode will be always turned ON in the case of the R model, or otherwise the S-APC mode will be always turned OFF. 3 9. Key Lock 13. List of Digital Display Items The key lock function disables the operation of all keys. Press the manual button for three seconds while pressing the mode button. Indicates that the keys are locked. • Take the same step to unlock the keys. 10. Mode Settings before Shipping (Initialization) The following factory settings are made before shipping. Access mode EASY Power mode FINE Timer function OFF Output selection Light-ON • To extend the cable length, use a cable with at least a 0.3 mm2 crosssection area. Limit the length of cable extension to no more than 100 m. (To connect several units, contact Keyence for further information.) • Do not wire the amplifier line along with power lines or high-tension lines, or otherwise the sensor may malfunction or receive damage due to noise. • When using a commercially available switching regulator, ground the frame ground terminal and ground terminal. • Do not use the FS series outdoors, or in a place where extraneous light can enter the light receiving surface directly. • Due to the individual dispersion of characteristics and the difference in fiber unit model, the maximum sensing distance or displayed value of all the units are not the same. • If the sensor is used in S-APC mode for a long time, the LED indicators will be imposed with a heavy load. In that case, the sensor will be automatically set to ACC mode where the current consumption of the sensor for light emission will be constant, and “END APC” will be displayed. The sensor can be continuously used in this case. Replace the sensor, however, if highly precise detection is required. Control output Supply voltage Current consumption Rating Environment resistance Mode Other than Normal R model ECO half ECO all R model Normal ECO half ECO all Ambient illumination Ambient temperature Relative humidity Vibration Shock resistance Housing material Size Weight Output selection (Light-ON) Timer function setting (One-shot timer) Access mode selection (EASY) S-APC mode setting (S-APC OFF) Access mode selection (FULL) S-APC mode setting (S-APC ON) Excess gain display Edge detection mode (OFF) LED bar display Edge detection mode (Rising edge) Hold display Edge detection mode (Falling edge) ECO mode setting (ECO mode OFF) Power mode selection (TURBO) ECO mode setting (ECO half) Power mode selection (SUPER TURBO) ECO mode setting (ECO all) Power mode selection (ULTRA TURBO) Shift function setting (Shift OFF) Power mode selection (HIGH SPEED) Shift function setting (Shift ON) Power mode selection (HIGH RESOLUTION) Key lock setting Timer function setting (Timer OFF) Key unlock WARRANTIES (MUST ACCOMPANY THE PRODUCTS): KEYENCE, at its sole option, will refund, repair or replace at no charge any defective Products within 1year from the date of shipment. Unless stated otherwise herein, the Products should not be used internally in humans, for human transportation, as safety devices or fail-safe systems. EXCEPT FOR THE FOREGOING, ALL EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. KEYENCE SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES, EVEN IF DAMAGES RESULT FROM THE USE OF THE PRODUCTS IN ACCORDANCE WITH ANY SUGGESTIONS OR INFORMATION PROVIDED BY KEYENCE. In some jurisdictions, some of the foregoing warranty disclaimers or damage limitations may not apply. FS-V22*1 FS-V22G FS-V22R(P) FS-V22X Red LED Greed LED 4-element red LED Infrared (950 nm) 250µs (FINE)/500µs (TURBO)/1ms (SUPER TURBO)/ 4ms (ULTRA TURBO)/500µs (HIGH RESOLUTION)/ 50µs (HIGH SPEED) Max. ±1999 (variable) Timer OFF, OFF-delay timer, ON-delay timer, and one-shot timer 1 to 500 ms NPN open collector with 100 mA max at 40 V with a max, Residual voltage of 1 V. DC12-24V ±10% with a maximum ripple (peak to peak) of 10% Model Timer function setting (ON-delay timer) Forecast maintenance warning (END APC) 12. Specifications Display shift function Timer function Output selection (Dark ON) button for a minimum of 11. Hints On Correct Use Response time Timer function setting (OFF-delay timer) Power mode selection (FINE) * Returning to factory settings: Press the five seconds while pressing the button. Model Light source Preset value/Current value display KEYENCE CORPORATION 1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku, Osaka, 533-8555, Japan PHONE: +81-6-6379-2211 FAX: +81-6-6379-2131 S-APC S-APC mode turned ON or when mode OFF the HIGH SPEED mode is selected. 580 mW 720 mW 480 mW 600 mW 430 mW 550 mW 650 mW 720 mW 530 mW 600 mW 480 mW 550 mW AFFILIATED COMPANIES KEYENCE CORPORATION OF AMERICA KEYENCE (THAILAND) CO., LTD. PHONE: 201-930-0100 PHONE: 02-369-2777 FAX: 201-930-0099 FAX: 02-369-2775 Incandescent lamp: 20,000 Rx max. Sunlight: 30,000 Rx max. -10°C to 55°C (No freezing)*2 35% to 85% RH (No condensation) 10 to 55 Hz, 1.5-mm double amplitude, each in X, Y, and Z directions for two hours 500 m/s2 Three times each in X, Y, and Z directions Unit and cover are both polycarbonate made W 9 mm x L70 mm x H 30 mm Approximately 80 g (including 2-m Cable) KEYENCE DEUTSCHLAND GmbH PHONE: 06102-36 89-0 FAX: 06102-36 89-100 KEYENCE TAIWAN CO., LTD. PHONE: 02-2627-3100 FAX: 02-2798-8925 KEYENCE (UK) LIMITED PHONE: 01908-696900 FAX: 01908-696777 KEYENCE (HONG KONG) CO., LTD. PHONE: 3104-1010 FAX: 3104-1080 KEYENCE FRANCE S.A. PHONE: 01 47 92 76 76 FAX: 01 47 92 76 77 *1. The model is sold only in Japan. Consult your KEYENCE representative if the model is required outside Japan. *2. Ambient operating temperature with amplifier expansion 1 to 2 units: -10°C to 55°C 3 to 10 units: -10°C to 50°C 11 to 16 units: -10°C to 45°C KEYENCE SINGAPORE PTE LTD. PHONE: 6392-1011 FAX: 6392-5055 KEYENCE (MALAYSIA) SDN BHD PHONE: 03-252-2211 FAX: 03-252-2131 4 KEYENCE INTERNATIONAL TRADING (SHANGHAI) CO., LTD. PHONE: 021-68757500 FAX: 021-68757550 KEYENCE KOREA CORPORATION PHONE: 02-563-1270 FAX: 02-563-1271 Printed in Japan
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement