CO1709
CO1709 MISTING Timer.indd 1 23/11/12 12:10 PM
Table of Contents
Technical Data..................................................................p1
Glossary............................................................................p2
Applications & Safety Instructions................................ p3
Connecting to the Tap..................................................... p4
Timer Control Glossary................................................... p5
Programming the Timer - AUTO RUN............................ p6
Programming the Timer - Manual ON or OFF................p7
Hints & Tips...................................................................... p8
Troubleshooting / Misting System Range..................... p9
Warranty / QR Code.........................................................Back Page
CO1709 MISTING Timer.indd 2 23/11/12 12:10 PM
Technical Data
Table of Contents
CO1709 MISTING Timer.indd 3
Technical Data
Tap Connection: 20mm BSP Female
Hose Connection: 12mm Hose
Snap-on or 20mm BSP Male
Water pressures: 100kPa - 500kPa
Water Temperature: Max. 40ºC
Irrigation Medium: Clean Water
Batteries: 2 x 1.5V AAA Alkaline
Batteries (Not Supplied) Change every 12 months.
1
23/11/12 12:10 PM
Glossary
1 2 3
2
1. Universal Tap Adaptor
2. Tap Connection
3. Union Nut
4. LCD Display
4
7
5
6
8
5. Control Keys
6. Battery Compartment
7. Clear Screw-on Cover
8. Snap-on Hose
Connection
Applications & Safety Instructions
The HOLMAN Misting Timer is designed for applications where you want to turn water “OFF” and “ON” at regular intervals. The timer will run “ON” for a minimum of 5 seconds and “OFF” for a minimum of 5 seconds. The maximum “OFF” time is 96 hours, 59 minutes, 59 seconds and the maximum “ON” time is 24 hours, 59 minutes, 59 seconds. Any time in 1 second intervals can be set between these limits.
Safety Instructions
For reasons of long life reliability, only use good quality ALKALINE batteries. Use only clean water.
To prevent the tap timer failing through weak batteries during a prolonged absence, the batteries must be replaced before re-use. The functional reliability of the tap timer depends on the functional capability of the batteries. Programme the tap timer before connecting to the water tap with the tap closed.
Use the tap timer in outdoor areas only. Before the start of the frost period the tap timer must be stored away from frost and damp. The temperature of water through the tap timer must not exceed 40ºC.
CO1709 MISTING Timer.indd 4 23/11/12 12:10 PM
Glossary
5. Control Keys
6. Battery Compartment
7. Clear Screw-on Cover
8. Snap-on Hose
Connection
Applications & Safety Instructions
The HOLMAN Misting Timer is designed for applications where you want to turn water “OFF” and “ON” at regular intervals. The timer will run “ON” for a minimum of 5 seconds and “OFF” for a minimum of 5 seconds. The maximum “OFF” time is 96 hours, 59 minutes, 59 seconds and the maximum “ON” time is 24 hours, 59 minutes, 59 seconds. Any time in 1 second intervals can be set between these limits.
Safety Instructions
For reasons of long life reliability, only use good quality ALKALINE batteries. Use only clean water.
To prevent the tap timer failing through weak batteries during a prolonged absence, the batteries must be replaced before re-use. The functional reliability of the tap timer depends on the functional capability of the batteries. Programme the tap timer before connecting to the water tap with the tap closed.
Use the tap timer in outdoor areas only. Before the start of the frost period the tap timer must be stored away from frost and damp. The temperature of water through the tap timer must not exceed 40ºC.
3
CO1709 MISTING Timer.indd 5 23/11/12 12:10 PM
Connecting to the Tap
Note: Firstly program the timer to the settings you require.
(See Programming on opposite page)
For connection you need a water tap with a 20mm or 25mm thread.
1. Unscrew the union nut (3) to enable the water tap connection (2) to move freely.
2. Screw the tap timer firmly onto the water tap by the tap connection. Turn the unit to face you so the
LCD Display (4) and Control Keys (5) can be easily seen.
3. Screw the Union Nut (3) up tight.
4. Connect your hose to the Snap-on Hose Connection (8) or unscrew the Hose Connection and screw on a misting filter or irrigation piping directly to the misting timer thread at the base of the unit.
Note: Screw the connection by hand. DO NOT use a wrench. Always keep the Clear Screw-on Cover
4
The Misting Timer is very easy to programme:
Note: Fit 2 x 1.5V AAA
ALKALINE Batteries
(Ensure they are good quality)
CO1709 MISTING Timer.indd 6 23/11/12 12:10 PM
Timer Controls Glossary
Connecting to the Tap
Note: Firstly program the timer to the settings you require.
(See Programming on opposite page)
For connection you need a water tap with a 20mm or 25mm thread.
1. Unscrew the union nut (3) to enable the water tap connection (2) to move freely.
2. Screw the tap timer fi rmly onto the water tap by the tap connection. Turn the unit to face you so the
LCD Display (4) and Control Keys (5) can be easily seen.
3. Screw the Union Nut (3) up tight.
4. Connect your hose to the Snap-on Hose Connection (8) or unscrew the Hose Connection and screw on a misting fi lter or irrigation piping directly to the misting timer thread at the base of the unit.
Note: Screw the connection by hand. DO NOT use a wrench. Always keep the Clear Screw-on Cover
(7) closed on the unit to prevent dirt from getting into the mechanism, preventing operation.
The Misting Timer is very easy to programme:
“OFF” Time
“ON” Time
Timer “ON” Manual
Auto Run
Note: Fit 2 x 1.5V AAA
ALKALINE Batteries
Reset Auto / Manual Operation
Increase
Decrease
Timer “OFF”
Set Time
5
CO1709 MISTING Timer.indd 7 23/11/12 12:10 PM
Programming the Timer - AUTO RUN Programming the Timer - Manual ON or OFF
Note: OFF & ON time is set in hours, minutes and seconds. Factory setting on power up is OFF 30 minutes & ON 3 Minutes.
Programming is easy, simply scroll through the digits and adjust them up or down. When setting “ AUTO” cycle, the LCD must show “ OFF”. Press the ON/AUTO/OFF button until “OFF” is shown.
STEP 1 - SET “OFF” TIME
Next
- SET “ON” TIME
A) Push SET Button - Adjust Hours Up or Down
B) Push SET Button - Adjust Minutes Up or Down
C) Push SET Button - Adjust Seconds Up or Down
A) Push SET Button - Adjust Hours Up or Down
B) Push SET Button - Adjust Minutes Up or Down
C) Push SET Button - Adjust Seconds Up or Down
STEP 2 - SET TO “AUTO RUN”
6
ON / AUTO / OFF Button until “AUTO” shows on the LCD. The unit will start watering.
Push ON / AUTO / OFF Button until “ON” or “OFF” shows on the LCD.
Notes:
- If in “ON” position the timer will stay OPEN.
- If in “OFF” position the timer is CLOSED.
- If in “AUTO” position the timer will sequentially run “OFF” time & then “ON” time.
- If you set “ON” or “OFF” time to less than 5 seconds the timer will stay “ON” or “OFF”
for 5 seconds.
- The timer will continue to turn “ON” & “OFF” as per the settings while in the “AUTO” mode.
CO1709 MISTING Timer.indd 8 23/11/12 12:10 PM
Programming the Timer - AUTO RUN Programming the Timer - Manual ON or OFF
Note: OFF & ON time is set in hours, minutes and seconds. Factory setting on power up is OFF 30 minutes & ON 3 Minutes.
Programming is easy, simply scroll through the digits and adjust them up or down. When setting “ AUTO” cycle, the LCD must show “ OFF”. Press the ON/AUTO/OFF button until “OFF” is shown.
STEP 1 - SET “OFF” TIME - SET “ON” TIME
A) Push SET Button - Adjust Hours Up or Down
B) Push SET Button - Adjust Minutes Up or Down
C) Push SET Button - Adjust Seconds Up or Down
A) Push SET Button - Adjust Hours Up or Down
B) Push SET Button - Adjust Minutes Up or Down
C) Push SET Button - Adjust Seconds Up or Down
STEP 2 - SET TO “AUTO RUN”
Push ON / AUTO / OFF Button until “AUTO” shows on the LCD. The unit will start watering.
Push ON / AUTO / OFF Button until “ON” or “OFF” shows on the LCD.
Notes:
- If in “ON” position the timer will stay OPEN.
- If in “OFF” position the timer is CLOSED.
- If in “AUTO” position the timer will sequentially run “OFF” time & then “ON” time.
- If you set “ON” or “OFF” time to less than 5 seconds the timer will stay “ON” or “OFF”
for 5 seconds.
- The timer will continue to turn “ON” & “OFF” as per the settings while in the “AUTO” mode.
7
CO1709 MISTING Timer.indd 9 23/11/12 12:10 PM
Hints & Tips
1. CHANGING BATTERIES
- Always wait for 5 minutes after you remove the batteries & install new ones.
- This allows time for the electronic circuit to “ RESET & CLEAR” itself.
- Always change batteries regularly. If using on rapid “ ON” & “OFF” cycles you may need to change
batteries more often.
2. RESET
- The “ RESET” Button can be used to “REBOOT” the electronic circuit.
- This will cancel all settings. Use a paperclip or small screwdriver to push the button through
the “ RESET” hole in the timer decal.
8
Troubleshooting Misting System Range
Troubleshooting Batteries
If battery power becomes low, the valve closes automatically. In this case please insert new ALKALINE batteries.
Checking Functionality Faults
Have batteries been correctly inserted?
Are the batteries flat?
Is the water tap open?
Is the program data correct?
has the unit been set to Manual OFF?
CO1709 MISTING Timer.indd 10 23/11/12 12:10 PM
Hints & Tips
1. CHANGING BATTERIES
- Always wait for 5 minutes after you remove the batteries & install new ones.
- This allows time for the electronic circuit to “ RESET & CLEAR” itself.
- Always change batteries regularly. If using on rapid “ ON” & “OFF” cycles you may need to change
batteries more often.
2. RESET
- The “ RESET” Button can be used to “REBOOT” the electronic circuit.
- This will cancel all settings. Use a paperclip or small screwdriver to push the button through
the “ RESET” hole in the timer decal.
Troubleshooting Misting System Range
Troubleshooting Batteries
If battery power becomes low, the valve closes automatically. In this case please insert new ALKALINE batteries.
Checking Functionality Faults
Have batteries been correctly inserted?
Are the batteries flat?
Is the water tap open?
Is the program data correct?
has the unit been set to Manual OFF?
MS20001 - Universal Misting Tap Adaptor (Qty x 1)
MS20002 - Misting Tee (Qty x 2)
MS20003 - Misting Elbow (Qty x 2)
MS20004 - Threaded Misting Tee with Jet (Qty x 2)
MS20005 - Threaded Misting Elbow with Jet (Qty x 2)
MS20006 - Mounting Clip with Masonry Nail (Qty x 10)
MS20007 - Misting Tube (5 Metres Flexible PVC)
MS20008 - Misting Tube Lengths 60cm (Qty x 5)
MS20009 - Brass & Stainless Steel Misting Jets (Qty x 5)
MS20010 - Brass Anti-Drain Valve (Qty x 1)
MS20011 - Plastic Misting Tube Cutter (Qty x 1)
MS20012 - Misting Filter (Qty x 1)
MK21013 - Misting System (Comprehensive Pack)
MK21014 - Misting System (Expansion Kit)
9
CO1709 MISTING Timer.indd 11 23/11/12 12:10 PM
Warranty
Warranty: We will honour all statutory
guarantees that this product is of acceptable quality.
(including that it is fi t for purpose)
HOLMAN Industries:
47 Walters Drive,
Osborne Park, WA 6017.
Ph: +61 8 9204 1011
www.holmanindustries.com.au
Scan the QR Code above to see more information on the
Misting System - including a product guide video.
CO1709 MISTING Timer.indd 12 23/11/12 12:10 PM