Moxa IMC-101-M-SC network media converter Installation guide

Add to my manuals
16 Pages

advertisement

Moxa IMC-101-M-SC network media converter Installation guide | Manualzz

Moxa Industrial Media Converter

IMC-101

Hardware Installation Guide

Fifth Edition, April 2010

 2010 Moxa Inc. All rights reserved.

Reproduction without permission is prohibited.

Fl.4, No.135, Lane 235, Pao-Chiao Rd. Shing Tien City, Taipei, Taiwan,

R.O.C.

TEL: +886-2-8919-1230

P/N: 1802001014024

Overview

Moxa Industrial Media Converter, which is specially designed for reliable and stable operation in harsh industrial environments, provides industrial grade media conversion between 10/100BaseT(X) and 100BaseFX. IMC-101’s reliable industrial design is excellent for keeping your industrial automation applications running continuously, and comes with a relay output warning alarm to help prevent damages and losses.

This product has a wide operating temperature range, from -40 to 75°C, and is designed to withstand a high degree of vibration and shock. The rugged hardware design makes IMC-101 perfect for ensuring that your Ethernet equipment can withstand critical industrial applications, such as in hazardous locations (Class 1 Division 2/Zone 2), and complies with FCC, TÜV, UL, and

CE Standards

NOTE Throughout this Hardware Installation Guide, we often use

IMC as an abbreviation for Moxa Industrial Media

Converter:

IMC = Moxa Industrial Media Converter

Package Checklist

Moxa Industrial Media Converter is shipped with the following items. If any of these items is missing or damaged, please contact your customer service representative for assistance.

 Moxa Industrial Media Converter

 Hardware Installation Guide

 Moxa Product Warranty booklet

Features

 Supports 10/100Base-TX auto-negotiation and auto-MDI/MDI-X

 Multi mode, single mode with SC or ST fiber connector available

 Supports Link Fault Pass-Through

 Relay Output alarm when a port breaks or the power fails

 Redundant 24 VDC (12 to 48 VDC) power inputs, DIN-Rail or panel mountable

 Operating temperature range from 0 to 60°C, or extended operating temperature from –40 to 75°C for (-T) models

- 2 -

Panel Layout of IMC-101 Series

Top Panel View

1

2

V2+

V2-

PWR2

FAULT

V1+

V1-

PWR1

V1 V2 INPUTS: 24 VDC

2. Terminal block for power input PWR1/PWR2 and relay

3 output

3. Heat dissipation orifices

PORT ALARM

4

5. Power input PWR1 LED

Front Panel View (IMC-101-M-ST)

2

5

6

7

6. Power input PWR2 LED

Port

9. FX port’s 100 Mbps LED

8

9

10

FDX/COL

10. FX port’s Full

Duplex/Collision LED

11. TP port’s 100 Mbps LED

12

14

11

13

12. 10/100BaseT(X)

13. TP port’s 10 Mbps LED

Front Panel View (IMC-101-M-SC)

2

5

6

7

Port

16. Screw hole for wall mounting kit

17. DIN-Rail mounting kit

15

9

10

FDX/COL

12

14

Rear Panel View

11

13

16

17

16

- 3 -

Mounting Dimensions

(Unit = mm)

30.00

9.50

54.00

13.10

15.10

25.40

135.00

135.00

25.71

39.37

Side View

+ +

Front View

13.90

18.20

13.90

3.5

6

3.5

6

+

+

+

7.75

13

+

+

+

+

+

30.50

18 13

10

10

5

6

57.05

66.80

7.75

46.77

+ +

23.15

10.65

30.50

10.65

Back View

+

+

+

+

+

+

Panel Mount Kit

- 4 -

DIN-Rail Mounting

The aluminum DIN-Rail attachment plate should be fixed to the back panel of

IMC when you take it out of the box. If you need to reattach the DIN-Rail attachment plate to IMC, make sure the stiff metal spring is situated towards the top, as shown in the figures below .

STEP 1:

Insert the top of the DIN-Rail into the slot just below the stiff metal spring.

STEP 2:

The DIN-Rail attachment unit will snap into place as shown below. metal spring metal spring

DIN-Rail

DIN-Rail

To remove Moxa Industrial Media Converter from the DIN-Rail, simply reverse Steps 1 and 2 above.

Wall Mounting (Optional)

For some applications, you will find it convenient to mount Moxa Industrial

Media Converter on the wall, as illustrated below.

STEP 1:

Remove the aluminum DIN-Rail attachment plate from Moxa Industrial Media

Converter, and then attach the wall mount plates, as shown in the diagrams below.

Top plate

Bottom plate

- 5 -

STEP 2:

Mounting Moxa Industrial Media Converter on the wall requires 4 screws. Use the IMC, with wall mount plates attached, as a guide to mark the correct locations of the 4 screws. The heads of the screws should be less than 6.0 mm in diameter, and the shafts should be less than 3.5 mm in diameter, as shown in the figure at the right.

6.0 mm

NOTE Test the screw head and shank size by inserting the screw into one of the keyhole shaped apertures of the Wall Mounting Plates, before it is screwed into the wall.

3.5 mm

Do not screw the screws in all the way—leave a space of about 2 mm to allow room for sliding the wall mount panel between the wall and the screws.

STEP 3:

Once the screws are fixed in the wall, insert the four screw heads through the large parts of the keyhole-shaped apertures, and then slide Moxa Industrial

Media Converter downwards, as indicated below. Tighten the four screws for added stability.

II 3G

ATEX Information

1. Certification number DEMKO 09 ATEX0812123x

2. Ambient range (-40°C ≤ Tamb ≤ 75°C)

3. Certification string (Ex nC nL IIC T4)

4. Standards covered ( EN60079-0:2006, EN60079-15:2005)

5. The conditions of safe usage:

 The Ethernet Communication Devices are to be mounted in an IP54 enclosure and used in an area of not more than pollution degree 2 as defined by IEC60664-1. A 4mm2 conductor must be used when a connection to the external grounding screw is used. Conductors suitable for use in an ambient temperature of 93°C must be used for the

Power Supply Terminal.

 Provisions shall be made, either in external to the apparatus, to prevent the rated voltage being exceeded by the transient disturbances of more than 40%.

- 6 -

Wiring Requirements

WARNING Do not disconnect modules or wires unless power has been switched off or the area is known to be non hazardous.

The devices may only be connected to the supply voltage shown on the type plate.

The devices are designed for operation with a safety extra-low voltage. Thus, they may only be connected to the supply voltage connections and to the signal contact with the safety extra-low voltages (SELV) in compliance with

IEC950/ EN60950/ VDE0805.

WARNING

Substitution of components may impair suitability for Class

I, Division 2 and Zone 2.

These devices must be supplied by a SELV source as defined in the Low Voltage Directive 73/23/EEC and 93/68/EEC.

WARNING This equipment has been evaluated as EEx nC IIC T4 equipment under DEMKO Certificate No. 03 ATEX

0324537U. Each module is marked with II 3G and is suitable for use in Zone 2 Explosive Atmospheres. Devices must be installed in a minimum IP 54 enclosure as defined in

IEC 60529 and EN 60529.

ATTENTION This unit is a built-in type. During installation into certain end equipment, it must comply with fire enclosure stipulations of IEC 60950/EN60950, or similar statements.

ATTENTION

Safety First!

Be sure to disconnect the power cord before installing and/or wiring your Moxa Industrial Media Converter.

ATTENTION

Safety First!

Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size.

If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your equipment.

- 7 -

You should also pay attention to the following points:

 Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross, make sure the wires are perpendicular at the intersection point.

NOTE: Do not run signal or communications wiring and power wiring in the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately.

 You can use the type of signal transmitted through a wire to determine which wires should be kept separate. The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together.

 Keep input wiring and output wiring separated.

 It is strongly advised that you label wiring to all devices in the system when necessary.

Grounding Moxa Industrial Media

Converter

Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the ground screw to the grounding surface prior to connecting devices.

ATTENTION This product is intended to be mounted to a well-grounded mounting surface such as a metal panel.

Wiring the Alarm Contact

The Alarm Contact is made up of the two middle contacts of the terminal block on IMC’s top panel. Refer to the next section for detailed instructions on how to connect the wires to the terminal block connector, and how to attach the terminal block connector to the terminal block receptor.

In this section, we explain the meaning of the two contacts used to connect the

Alarm Contact.

Top View

FAULT

FAULT: The two middle contacts of the

6-contact terminal block connector are used to detect both power faults and port faults. The two wires attached to the Fault contacts form an open circuit when:

FAULT

1. IMC has lost power from one of the DC power inputs.

OR

Front View

2. One of the ports for which the corresponding

PORT ALARM Dip Switch is set to ON is not properly connected.

If neither of these two conditions occurs, the Fault circuit will be closed.

- 8 -

Wiring the Redundant Power Inputs

The top two contacts and the bottom two contacts of the 6-contact terminal block connector on IMC’s top panel are used for IMC’s two DC inputs. Top and front views of one of the terminal block connectors are shown here.

Top View

Front View

STEP 1: Insert the negative/positive DC wires into the V-/V+ terminals.

STEP 2: To keep the DC wires from pulling loose, use a small flat-blade screwdriver to tighten the wire-clamp screws on the front of the terminal block connector.

STEP 3: Insert the plastic terminal block connector prongs into the terminal block receptor, which is located on IMC’s top panel.

ATTENTION

Before connecting IMC to the DC power inputs, make sure the DC power source voltage is stable.

Communication Connections

IMC-101 models have one 10/100BaseT(X) Ethernet port, and one 100BaseFX

(SC or ST type connector) fiber port.

10/100BaseT(X) Ethernet Port Connection

The 10/100BaseT(X) ports located on IMC’s front panel are used to connect to

Ethernet-enabled devices.

Below we show pinouts for both MDI (NIC-type) ports and MDI-X

(HUB/Switch-type) ports, and also show cable wiring diagrams for straight-through and cross-over Ethernet cables.

RJ45 (8-pin, MDI) Port Pinouts RJ45 (8-pin, MDI-X) Port Pinouts

Pin

3

6

1

2

Signal

Tx+

Tx-

Rx+

Rx-

1 8

Pin

3

6

1

2

Signal

Rx+

Rx-

Tx+

Tx-

1 8

RJ45 (8-pin) to RJ45 (8-pin) Straight-Through Cable Wiring

Switch Port

RJ45

Connector

Tx+

Tx-

Rx+

Rx-

Straight-Through Cable

3

6

1

2

RJ45 Plug Pin 1

Cable Wiring

3

6

1

2

NIC Port

RJ45

Connector

Rx+

Rx-

Tx+

Tx-

- 9 -

RJ45 (8-pin) to RJ45 (8-pin) Cross-Over Cable Wiring

Switch Port

(NIC Port)

RJ45

Connector

(Rx+)

(Rx-)

(Tx+)

(Tx-)

Tx+

Tx-

Rx+

Rx-

Cross-Over Cable

3

6

1

2

RJ45 Plug Pin 1

Cable Wiring

1

2

3

6

Switch Port

(NIC Port)

RJ45

Connector

Rx+

Rx-

Tx+

Tx-

(Tx+)

(Tx-)

(Rx+)

(Rx-)

100BaseFX Ethernet Port Connection

The concept behind the SC port and cable is quite straightforward. Suppose you are connecting devices I and II. Contrary to electrical signals, optical signals do not require a circuit in order to transmit data. Consequently, one of the optical lines is used to transmit data from device I to device II, and the other optical line is used transmit data from device II to device I, for full-duplex transmission.

All you need to remember is to connect the Tx (transmit) port of device I to the

Rx (receive) port of device II, and the Rx (receive) port of device I to the Tx

(transmit) port of device II. If you are making your own cable, we suggest labeling the two sides of the same line with the same letter (A-to-A and B-to-B, as shown below, or A1-to-A2 and B1-to-B2).

SC-Port Pinouts SC-Port to SC-Port Cable Wiring

A A

Tx

B B

Rx

ST-Port Pinouts

A

B

Cable Wiring

A

B

ST-Port to ST-Port Cable Wiring

A A

Tx

B B

Rx

A

B

Cable Wiring

A

B

ATTENTION

This is a Class 1 Laser/LED product. Do not stare into the

Laser Beam.

- 10 -

Redundant Power Inputs

Both power inputs can be connected simultaneously to live DC power sources.

If one power source fails, the other live source acts as a backup, and automatically supplies all of Moxa Industrial Media Converter’s power needs.

Alarm Contact

Moxa Industrial Media Converter has one Alarm Contact located on the top panel. For detailed instructions on how to connect the Alarm Contact power wires to the two middle contacts of the 6-contact terminal block connector, see the “Wiring the Alarm Contact” section above. A typical scenario would be to connect the Fault circuit to a warning light located in the control room. The light can be set up to switch on when a fault is detected.

The Alarm Contact has two terminals that form a Fault circuit for connecting to an alarm system. The two wires attached to the Fault contacts form an open circuit when (1) IMC has lost power from one of the DC power inputs, or (2) one of the ports for which the corresponding PORT ALARM Dip Switch is set to ON is not properly connected.

If neither of these two conditions occurs, the Fault circuit will be closed.

Dip Switch Setting

IMC-101 series DIP switch

ON DIP

1 2 3

Dip Switch 1 (Default: Off )

ON: Enables the PORT Alarm. If the port’s link fails, the relay will form an open circuit and the fault LED will light up.

Off: Disables the corresponding PORT Alarm. The relay will form a closed circuit and the Fault LED will never light up.

Dip Switch 2 (Default: ON )

ON: Enables full duplex for 100BaseFX

Off: Disables full duplex for 100BaseFX

Dip Switch 3

Reserved for future use

To activate the updated DIP switch setting, power off and then power on the

IMC.

- 11 -

LED Indicators

The front panel of Moxa Industrial Media Converter contains several LED indicators. The function of each LED is described in the table below.

LED Color State Description

Power is being supplied to power input PWR1

PWR1 AMBER

On

Off

Power is not being supplied to power input PWR1

PWR2

AMBER

FAULT

RED

On

Off

On

Off

Power is being supplied to power input PWR2

Power is not being supplied to power input PWR2

When the corresponding PORT alarm is enabled, and the port’s link is inactive.

When the corresponding PORT alarm is enabled and the port’s link is active, or when the corresponding PORT alarm is disabled.

On

10M

GREEN Blinking

Off

On

TP port’s 10 Mbps link is active

Data is being transmitted at 10

Mbps

TP Port’s 10 Mbps link is inactive

TP port’s 100 Mbps link is active

100M

(TP)

GREEN Blinking

Data is being transmitted at 100

Mbps

100M

(FX)

GREEN

Off

On

Blinking

Off

On

100BaseTX Port’s link is inactive

FX port’s 100 Mbps is active

Data is being transmitted at 100

Mbps

100BaseFX port is inactive

100BaseFX port is being transmitted at full duplex

FDX/

COL

GREEN

Off

100BaseFX port is being transmitted at half duplex

- 12 -

Auto MDI/MDI-X Connection

The Auto MDI/MDI-X function allows users to connect Moxa Industrial Media

Converter’s 10/100BaseTX ports to any kind of Ethernet device, without paying attention to the type of Ethernet cable being used for the connection.

This means that you can use either a straight-through cable or cross-over cable to connect IMC to Ethernet devices.

Dual Speed Functionality and

Switching

Moxa Industrial Media Converter’s 10/100 Mbps RJ45 switched port auto negotiates with the connected device for the fastest data transmission rate supported by both devices. All models of Moxa Industrial Media Converter are plug-and-play devices, so that software configuration is not required at installation, or during maintenance. The half/full duplex mode for the RJ45 switched ports is user dependent and changes (by auto-negotiation) to full or half duplex, depending on which transmission speed is supported by the attached device.

Auto-Negotiation and Speed Sensing

All of Moxa Industrial Media Converter’s RJ45 Ethernet ports independently support auto-negotiation for transmission speed in the 10BaseT and

100BaseTX modes, with operation according to the IEEE 802.3u standard.

This means that some nodes could be operating at 10 Mbps, while at the same time, other nodes are operating at 100 Mbps.

Auto-negotiation takes place when an RJ45 cable connection is made, and then each time a LINK is enabled. Moxa Industrial Media Converter advertises its capability for using either 10 Mbps or 100 Mbps transmission speeds, with the device at the other end of the cable expected to advertise similarly. Depending on what type of device is connected, this will result in agreement to operate at a speed of either 10 Mbps or 100 Mbps.

If a Moxa Industrial Media Converter RJ45 Ethernet port is connected to a non-negotiating device, it will default to 10 Mbps speed and half-duplex mode, as required by the IEEE 802.3u standard.

- 13 -

Specifications

Technology

Standards

Interface

RJ45 ports

Fiber ports

LED Indicators

Dip Switch

Alarm Contact

Optical Fiber

IEEE802.3, 802.3u, Link Fault Pass-Through

10/100BaseT(X)

100BaseFX (SC, ST connectors available)

Power, Fault, 10/100M, Full Duplex/Collision,

Port break alarm mask, 100BaseFx Full/Half duplex selection

One relay output with current carrying capacity of

1A @ 24 VDC

Multi mode

Single mode, 15

Single mode, 40

Single mode, 80

Distance, km

Wavelength, nm

Min. TX Output, dBm

Max. TX Output, dBm

Sensitivity, dBm -34 to -30 -36 to -32 -36 to -32 -36 to -32

Recommended Diameter 62.5/125 9/125 9/125 9/125

Power

Input Voltage

800 MHz  km)

24 VDC (12 to 48 VDC); Redundant inputs

Input Current (@24V)

Connection

0.16 A

Removable Terminal Block

Overload Current Protection1.1 A

Reverse Polarity Protection Present

Mechanical

Casing IP30 protection, aluminum case

Dimensions (W x H x D) 53.6 x 135 x 105 mm

Weight 0.63 kg

Environmental

Operating Temperature

Storage Temperature -40 to 85 ( o F),

-40 to 75 o C (-40 to 167 o F) for – T models

-40 to 185 o F)

Ambient Relative Humidity 5 to 90% (non-condensing)

Regulatory Approvals

Safety UL60950, UL 508, CSA C22.2 No. 60950,

EN60950

Hazardous Location UL/cUL Class I, Division 2, Groups A, B, C and D

ATEX Class I, Zone 2, EEx nC IIC

EMI

EMS

FCC Part 15, CISPR (EN55022) class A

EN61000-4-2 (ESD), level 3

- 14 -

EN61000-4-3 (RS), level 3

EN61000-4-4 (EFT), level 3

EN61000-4-5 (Surge), level 2

EN61000-4-2 (CS), level 3

IEC 60068-2-32 Free Fall

WARRANTY 5 years

Revision History

Document Edition Revision Date

2nd June 15, 2004 1.

Revision Details

Updated the edition of this manual on the title page.

2. Changed the Moxa logo on the title page.

3. Added several “Attention” messages

4. Added one product feature:

Operating temperature ranges from 0 to 60°C, or extended operting temperature from –40 to

75°C for (-T) models.

3rd

4th

July 1, 2004 1. Revise 100BaseFX for fiber optic port of ST connector.

Nov. 15, 2004 1. Modify Optical Fiber specs.

2. Improve resolution of figures.

- 15 -

Serial Number

The serial number of a product is made up of 12 alphanumeric characters and includes the region in which the product was manufactured, the year and month the product was manufactured, the product category, and the production number.

Position in Serial

Number

Meaning Possible

Values

Example(s)

2 and 3

4

Region

Year

Month

0 to 9, or “T” means Taiwan

D to Z

Z = 0,

A = 1,

B = 2,

......

I = 9

ZH = 2008,

II = 2009

A = JAN,

B = FEB,

C = MAR,

......

L = DEC

5 ---

6 and 7 Product

Category

0 Reserved for future use

B-type: 00, 01, ..., 09

E-type: 10, 11, ..., 99

8 to 12 Production B-type: 00001 to 65535

Number E-type: 00001 to 99999

For example, a product with serial number TZDL012012456 was manufactured in Taiwan in December of 2004, is an E-type 12 product, and is the 12,456 th product of this type that has been manufactured.

Technical Support Contact Information

www.moxa.com/support

Moxa Americas:

Toll-free: 1-888-669-2872

Tel: +1-714-528-6777

Fax: +1-714-528-6778

Moxa China (Shanghai office):

Toll-free: 800-820-5036

Tel: +86-21-5258-9955

Fax: +86-10-6872-3958

Moxa Europe:

Tel: +49-89-3 70 03 99-0

Fax: +49-89-3 70 03 99-99

Moxa Asia-Pacific:

Tel: +886-2-8919-1230

Fax: +886-2-8919-1231

- 16 -

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement