electronic time switches
First Generation
Next Generation
ELECTRONIC TIME SWITCHES
ELECTRONIC TIME SWITCHES
ELECTRONIC TIME SWITCHES
Full Year
ET70115C
ET70115CR
ET70215C
ET70215CR
Independent Circuit(s)
1
Switch
SPDT
Programming Events (minimum)
1,000
Astro (sunrise/sunset)**
•
•
Pulse (momentary 1 to 127 sec.)**
Interval (time of day)**
•
Interval (user selectable override)**
Remote†††
Holiday Programming (up to 99)
•
Holiday Duration (any length)
•
Auto Daylight Savings Adjustment
•
Lifetime Memory for Program Data
•
8-Year Battery Backup Timekeeping
•
Isolated Logic Board/6,000V Transient Protection
•
Power Input 120/208/240/277 VAC 50/60Hz
•
Power Input 24 VAC 60 Hz (add “24” suffix)
20
Amps (general purpose) 12–277V†
20
Amps ballast 120–277V†
2/1
HP 240V† / HP 120V†
5
Amps Tungsten/TV 120–240V†
470VA
Pilot Duty 12–240V†
Lockable Steel Enclosure
NEMA 1
1
SPDT
1,000
•
•
•
Remote†††
•
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
2
SPDT
1,000
•
•
•
Remote†††
•
•
•
•
•
•
•
2
SPDT
1,000
•
•
•
Remote†††
•
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
Next Generation
20
20
2/1
5
470VA
NEMA 1
ET70415CR‡ ET70815CR‡ ET71615CR‡
4
SPDT
1,000
•
•
•
Remote††
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
8
SPDT
4,000
•
•
•
Remote††
•
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
16
SPDT
4,000
•
•
•
Remote††
•
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
* Depends on data entry type **All circuits, independently programmable †Switch ratings per pole–normally open contacts
††
Includes remote override for 4 circuits (up to 1,000 ft. away). To expand to max. # of circuits, order accessory #156ET9402A for ET70815CR or #156ET9403A for ET71615CR.
†††
For remote override, order accessory #ET7232M (flush or raintight) or #ET7232M1 (surface mount).
First Generation
Independent Circuit(s)
Switch
Power Input
Program Events
3-Year Battery Backup
Amps
HP 240V (Watts)
HP 120V (Watts)
Enclosure
Water Heater
EH10
EH40
1
SPST
120V
12
•
30
(3600)
NEMA 1
1
DPST
240V
12
•
30
(7200)
NEMA 1
Low Cost 24 Hour w/ 3R
EP101CP3
EP104CP3
1
SPST
120V
8
•
30
2
1
NEMA 3R
1
DPST
240V
8
•
30
2
1
NEMA 3R
24 Hour
ET100C
ET101C
ET102C
ET103C
ET104C
ET105C
1
SPST
120V
8
•
30
2
1
NEMA 1
1
SPST
120V
8
•
30
2
1
NEMA 1
1
SPST
120–277V
8
•
30
2
1
NEMA 1
1
DPST
120V
8
•
30
2
1
NEMA 1
1
DPST
120–277V
8
•
30
2
1
NEMA 1
1
SPDT
120V
8
•
30
2
1
NEMA 1
7 Day
First Generation
THE ULTIMATE IN APPLICATION-SPECIFIC CONTROL
Our first generation of electronic time switches provides
dependable, to-the-minute control and reduced energy costs for a
wide variety of basic applications. As a snap-in upgrade or for new
installations, these models offer ease of programming and a 3-year
battery backup, at a modest cost compared to mechanical time
switches.
STANDARD FEATURES
• To-the-minute programming
• Up to 28 set points
• 3 year battery backup
• Slide switch or push-button programming
• 120, 240 or 277V input
• 1 and 2 circuit models
Independent Circuit(s)
Switch
Power Input
Special Features
Program Events*
Battery Backup
Amps
HP 240V†
HP 120V†
Enclosure
Inwall
7 Day/24 hr
7 Day with Features
ET171C ET171CR E173C
E174C ET175C ET279C
1
SPST
120V
1
DPST
240V
1
SPST
120V
1
DPST
120V
1
SPDT
120V
2
SPST
120V
ET715C ET718C ET728C
1
SPST
120V
Pulse Output
1
4PDT
120V
1
4PDT
120V
ET799C ET716CK EI20 /EI40
1
2PST
120V
SM Series Lighting Control Panels provide control for billboards or other lighting control applications. They include an electronic or mechanical time switch, a main disconnect and up to nine
20 Amp 120V breakers. One and two circuit models are available as are photo control, lightning
arrestor and stainless enclosure options. Request Form # 300SM10001 for more information.
CONTROL
JUST ABOUT
E V E RY T H I N G
1
DPDT
1
SP & 3 way
120/240/277V 12–277V
Multi-Zone Soft Start Pulse Output Photo Sensor Prog./Countdown
20
20
20
20
20
20
28
28
28
28
3 yr
3 yr
3 yr
3 yr
3 yr
3 yr
5 yr
5 yr
5 yr
5 yr
30
30
30
30
30
30
5
5
5
5
2
2
2
2
2
2
1
1
1
1
1
1
NEMA 1 NEMA 3R NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1
Lighting Control Panels
ELECTRONIC TIME SWITCHES
28
5 yr
5
6/NA
3 yr
16
2
1
NEMA 1 wall mount
Intermatic Incorporated
Spring Grove, Illinois 60081-9698
www.intermatic.com
www.energycontrols.com
©2002 Intermatic, Inc.
Printed in U.S.A. 300ET10011
THE ULTIMATE IN APPLICATION-SPECIFIC CONTROL
The Next Generation design is the result of a collaboration of
electrical contractors, engineers, distributors and product
designers. . .backed by the control expertise of the world's leading
time switch manufacturer. These microprocessor-controlled models
offer the ultimate in control and application flexibility. New remote
override and network connection options move the Next Generation
even further ahead of the competition.
www.intermatic.com/energycontrols
STANDARD FEATURES
• Daily, weekly or yearly scheduling
• Fixed, astro, pulse and interval
• Holiday programming (to 99 schedules)
• Lifetime memory for program data
• 8 year battery maintains timekeeping
• 120, 208, 240 or 277V input
• 1, 2, 4, 8 and 16 circuit models
• Auto review for easy program review,
with help messages for omissions.
First Generation
Next Generation
ELECTRONIC TIME SWITCHES
ELECTRONIC TIME SWITCHES
ELECTRONIC TIME SWITCHES
Full Year
ET70115C
ET70115CR
ET70215C
ET70215CR
Independent Circuit(s)
1
Switch
SPDT
Programming Events (minimum)
1,000
Astro (sunrise/sunset)**
•
•
Pulse (momentary 1 to 127 sec.)**
Interval (time of day)**
•
Interval (user selectable override)**
Remote†††
Holiday Programming (up to 99)
•
Holiday Duration (any length)
•
Auto Daylight Savings Adjustment
•
Lifetime Memory for Program Data
•
8-Year Battery Backup Timekeeping
•
Isolated Logic Board/6,000V Transient Protection
•
Power Input 120/208/240/277 VAC 50/60Hz
•
Power Input 24 VAC 60 Hz (add “24” suffix)
20
Amps (general purpose) 12–277V†
20
Amps ballast 120–277V†
2/1
HP 240V† / HP 120V†
5
Amps Tungsten/TV 120–240V†
470VA
Pilot Duty 12–240V†
Lockable Steel Enclosure
NEMA 1
1
SPDT
1,000
•
•
•
Remote†††
•
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
2
SPDT
1,000
•
•
•
Remote†††
•
•
•
•
•
•
•
2
SPDT
1,000
•
•
•
Remote†††
•
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
Next Generation
20
20
2/1
5
470VA
NEMA 1
ET70415CR‡ ET70815CR‡ ET71615CR‡
4
SPDT
1,000
•
•
•
Remote††
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
8
SPDT
4,000
•
•
•
Remote††
•
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
16
SPDT
4,000
•
•
•
Remote††
•
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
* Depends on data entry type **All circuits, independently programmable †Switch ratings per pole–normally open contacts
††
Includes remote override for 4 circuits (up to 1,000 ft. away). To expand to max. # of circuits, order accessory #156ET9402A for ET70815CR or #156ET9403A for ET71615CR.
†††
For remote override, order accessory #ET7232M (flush or raintight) or #ET7232M1 (surface mount).
First Generation
Independent Circuit(s)
Switch
Power Input
Program Events
3-Year Battery Backup
Amps
HP 240V (Watts)
HP 120V (Watts)
Enclosure
Water Heater
EH10
EH40
1
SPST
120V
12
•
30
(3600)
NEMA 1
1
DPST
240V
12
•
30
(7200)
NEMA 1
Low Cost 24 Hour w/ 3R
EP101CP3
EP104CP3
1
SPST
120V
8
•
30
2
1
NEMA 3R
1
DPST
240V
8
•
30
2
1
NEMA 3R
24 Hour
ET100C
ET101C
ET102C
ET103C
ET104C
ET105C
1
SPST
120V
8
•
30
2
1
NEMA 1
1
SPST
120V
8
•
30
2
1
NEMA 1
1
SPST
120–277V
8
•
30
2
1
NEMA 1
1
DPST
120V
8
•
30
2
1
NEMA 1
1
DPST
120–277V
8
•
30
2
1
NEMA 1
1
SPDT
120V
8
•
30
2
1
NEMA 1
7 Day
First Generation
THE ULTIMATE IN APPLICATION-SPECIFIC CONTROL
Our first generation of electronic time switches provides
dependable, to-the-minute control and reduced energy costs for a
wide variety of basic applications. As a snap-in upgrade or for new
installations, these models offer ease of programming and a 3-year
battery backup, at a modest cost compared to mechanical time
switches.
STANDARD FEATURES
• To-the-minute programming
• Up to 28 set points
• 3 year battery backup
• Slide switch or push-button programming
• 120, 240 or 277V input
• 1 and 2 circuit models
Independent Circuit(s)
Switch
Power Input
Special Features
Program Events*
Battery Backup
Amps
HP 240V†
HP 120V†
Enclosure
Inwall
7 Day/24 hr
7 Day with Features
ET171C ET171CR E173C
E174C ET175C ET279C
1
SPST
120V
1
DPST
240V
1
SPST
120V
1
DPST
120V
1
SPDT
120V
2
SPST
120V
ET715C ET718C ET728C
1
SPST
120V
Pulse Output
1
4PDT
120V
1
4PDT
120V
ET799C ET716CK EI20 /EI40
1
2PST
120V
SM Series Lighting Control Panels provide control for billboards or other lighting control applications. They include an electronic or mechanical time switch, a main disconnect and up to nine
20 Amp 120V breakers. One and two circuit models are available as are photo control, lightning
arrestor and stainless enclosure options. Request Form # 300SM10001 for more information.
CONTROL
JUST ABOUT
E V E RY T H I N G
1
DPDT
1
SP & 3 way
120/240/277V 12–277V
Multi-Zone Soft Start Pulse Output Photo Sensor Prog./Countdown
20
20
20
20
20
20
28
28
28
28
3 yr
3 yr
3 yr
3 yr
3 yr
3 yr
5 yr
5 yr
5 yr
5 yr
30
30
30
30
30
30
5
5
5
5
2
2
2
2
2
2
1
1
1
1
1
1
NEMA 1 NEMA 3R NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1
Lighting Control Panels
ELECTRONIC TIME SWITCHES
28
5 yr
5
6/NA
3 yr
16
2
1
NEMA 1 wall mount
Intermatic Incorporated
Spring Grove, Illinois 60081-9698
www.intermatic.com
www.energycontrols.com
©2002 Intermatic, Inc.
Printed in U.S.A. 300ET10011
THE ULTIMATE IN APPLICATION-SPECIFIC CONTROL
The Next Generation design is the result of a collaboration of
electrical contractors, engineers, distributors and product
designers. . .backed by the control expertise of the world's leading
time switch manufacturer. These microprocessor-controlled models
offer the ultimate in control and application flexibility. New remote
override and network connection options move the Next Generation
even further ahead of the competition.
www.intermatic.com/energycontrols
STANDARD FEATURES
• Daily, weekly or yearly scheduling
• Fixed, astro, pulse and interval
• Holiday programming (to 99 schedules)
• Lifetime memory for program data
• 8 year battery maintains timekeeping
• 120, 208, 240 or 277V input
• 1, 2, 4, 8 and 16 circuit models
• Auto review for easy program review,
with help messages for omissions.
First Generation
Next Generation
ELECTRONIC TIME SWITCHES
ELECTRONIC TIME SWITCHES
ELECTRONIC TIME SWITCHES
Full Year
ET70115C
ET70115CR
ET70215C
ET70215CR
Independent Circuit(s)
1
Switch
SPDT
Programming Events (minimum)
1,000
Astro (sunrise/sunset)**
•
•
Pulse (momentary 1 to 127 sec.)**
Interval (time of day)**
•
Interval (user selectable override)**
Remote†††
Holiday Programming (up to 99)
•
Holiday Duration (any length)
•
Auto Daylight Savings Adjustment
•
Lifetime Memory for Program Data
•
8-Year Battery Backup Timekeeping
•
Isolated Logic Board/6,000V Transient Protection
•
Power Input 120/208/240/277 VAC 50/60Hz
•
Power Input 24 VAC 60 Hz (add “24” suffix)
20
Amps (general purpose) 12–277V†
20
Amps ballast 120–277V†
2/1
HP 240V† / HP 120V†
5
Amps Tungsten/TV 120–240V†
470VA
Pilot Duty 12–240V†
Lockable Steel Enclosure
NEMA 1
1
SPDT
1,000
•
•
•
Remote†††
•
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
2
SPDT
1,000
•
•
•
Remote†††
•
•
•
•
•
•
•
2
SPDT
1,000
•
•
•
Remote†††
•
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
Next Generation
20
20
2/1
5
470VA
NEMA 1
ET70415CR‡ ET70815CR‡ ET71615CR‡
4
SPDT
1,000
•
•
•
Remote††
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
8
SPDT
4,000
•
•
•
Remote††
•
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
16
SPDT
4,000
•
•
•
Remote††
•
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
* Depends on data entry type **All circuits, independently programmable †Switch ratings per pole–normally open contacts
††
Includes remote override for 4 circuits (up to 1,000 ft. away). To expand to max. # of circuits, order accessory #156ET9402A for ET70815CR or #156ET9403A for ET71615CR.
†††
For remote override, order accessory #ET7232M (flush or raintight) or #ET7232M1 (surface mount).
First Generation
Independent Circuit(s)
Switch
Power Input
Program Events
3-Year Battery Backup
Amps
HP 240V (Watts)
HP 120V (Watts)
Enclosure
Water Heater
EH10
EH40
1
SPST
120V
12
•
30
(3600)
NEMA 1
1
DPST
240V
12
•
30
(7200)
NEMA 1
Low Cost 24 Hour w/ 3R
EP101CP3
EP104CP3
1
SPST
120V
8
•
30
2
1
NEMA 3R
1
DPST
240V
8
•
30
2
1
NEMA 3R
24 Hour
ET100C
ET101C
ET102C
ET103C
ET104C
ET105C
1
SPST
120V
8
•
30
2
1
NEMA 1
1
SPST
120V
8
•
30
2
1
NEMA 1
1
SPST
120–277V
8
•
30
2
1
NEMA 1
1
DPST
120V
8
•
30
2
1
NEMA 1
1
DPST
120–277V
8
•
30
2
1
NEMA 1
1
SPDT
120V
8
•
30
2
1
NEMA 1
7 Day
First Generation
THE ULTIMATE IN APPLICATION-SPECIFIC CONTROL
Our first generation of electronic time switches provides
dependable, to-the-minute control and reduced energy costs for a
wide variety of basic applications. As a snap-in upgrade or for new
installations, these models offer ease of programming and a 3-year
battery backup, at a modest cost compared to mechanical time
switches.
STANDARD FEATURES
• To-the-minute programming
• Up to 28 set points
• 3 year battery backup
• Slide switch or push-button programming
• 120, 240 or 277V input
• 1 and 2 circuit models
Independent Circuit(s)
Switch
Power Input
Special Features
Program Events*
Battery Backup
Amps
HP 240V†
HP 120V†
Enclosure
Inwall
7 Day/24 hr
7 Day with Features
ET171C ET171CR E173C
E174C ET175C ET279C
1
SPST
120V
1
DPST
240V
1
SPST
120V
1
DPST
120V
1
SPDT
120V
2
SPST
120V
ET715C ET718C ET728C
1
SPST
120V
Pulse Output
1
4PDT
120V
1
4PDT
120V
ET799C ET716CK EI20 /EI40
1
2PST
120V
SM Series Lighting Control Panels provide control for billboards or other lighting control applications. They include an electronic or mechanical time switch, a main disconnect and up to nine
20 Amp 120V breakers. One and two circuit models are available as are photo control, lightning
arrestor and stainless enclosure options. Request Form # 300SM10001 for more information.
CONTROL
JUST ABOUT
E V E RY T H I N G
1
DPDT
1
SP & 3 way
120/240/277V 12–277V
Multi-Zone Soft Start Pulse Output Photo Sensor Prog./Countdown
20
20
20
20
20
20
28
28
28
28
3 yr
3 yr
3 yr
3 yr
3 yr
3 yr
5 yr
5 yr
5 yr
5 yr
30
30
30
30
30
30
5
5
5
5
2
2
2
2
2
2
1
1
1
1
1
1
NEMA 1 NEMA 3R NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1
Lighting Control Panels
ELECTRONIC TIME SWITCHES
28
5 yr
5
6/NA
3 yr
16
2
1
NEMA 1 wall mount
Intermatic Incorporated
Spring Grove, Illinois 60081-9698
www.intermatic.com
www.energycontrols.com
©2002 Intermatic, Inc.
Printed in U.S.A. 300ET10011
THE ULTIMATE IN APPLICATION-SPECIFIC CONTROL
The Next Generation design is the result of a collaboration of
electrical contractors, engineers, distributors and product
designers. . .backed by the control expertise of the world's leading
time switch manufacturer. These microprocessor-controlled models
offer the ultimate in control and application flexibility. New remote
override and network connection options move the Next Generation
even further ahead of the competition.
www.intermatic.com/energycontrols
STANDARD FEATURES
• Daily, weekly or yearly scheduling
• Fixed, astro, pulse and interval
• Holiday programming (to 99 schedules)
• Lifetime memory for program data
• 8 year battery maintains timekeeping
• 120, 208, 240 or 277V input
• 1, 2, 4, 8 and 16 circuit models
• Auto review for easy program review,
with help messages for omissions.
Next Generation
First Generation
ELECTRONIC TIME SWITCHES
ELECTRONIC TIME SWITCHES
Factory
Pre-Programming
Pre-installation of your
specific program requirements
available on quantity orders
of 50 + (ET70000CR Series.)
EI20C
ET279C *
ET70215C & ET70215CR
ET70115C & ET70115CR
ET70415CR
ET70815CR
New Connectivity Features
Full Year
Water Heater 7 day
ET100C SERIES
EP100C SERIES
EH10 / EH40
ET71615CR
Low Cost 24hr. with 3R
ET170C SERIES *
7 Day
24 Hour
EI40C
ET700C SERIES *
7 Day with Features
In Wall
Remote override for
1 and 2 circuit
FOR CONTROLLING
• Water heaters
• HVAC
• Commercial ovens
• Lighting
• Fans, blowers and
pumps
• Bells and signals
• Process equipment
• Poultry equipment
• Livestock feeders
NEMA 1 installation with
surface mount junction box
RS232 Interface
NEMA 3R installation with
flush or raintight junction box
SPECIFICATIONS
SPECIFICATIONS
1 or 2 circuit
SPECIFICATIONS
4 circuit
NEMA 3R enclosure option
Lifetime memory with 1,000+ events
Astronomic or pulse programming
20 Amp ballast @ 120–277V
120–277V 50/60 Hz
SPDT contacts
Remote override option
CIRCUIT #1
CIRCUIT #2
TIMER
POWER
EQUIPMENT
GROUND
1
2
3
4
5
6
7
8
NEUTRAL
277 VAC
CLOSE
HOT
COM
OPEN
Latching
Relay
OUTDOOR
LIGHTING
8 circuit
Independent control
Lifetime memory with 1,000+ events
Astronomic or pulse programming
20 Amp ballast @ 120–277V
120–277V input 50/60 Hz
Remote override
E
Independent control
Lifetime memory with 4,000+ events
Astronomic or pulse programming
20 Amp ballast @ 120–277V
120–277V 50/60 Hz
Remote override
SPECIFICATIONS
REMOTE OVERRIDE
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
16 circuit
Allows for manual control of loads using
remotely-located switches (up to 1,000 ft.
from time switch). Uses interface hardware
shown above. For 1 and 2 circuit.
• Residential
• Commercial,
industrial,
institutional and
military facilities
Up to 12 events
3 year alkaline backup
3,600 Watts @ 120V
7,200 Watts @ 240V
120–240V 50/60 Hz
• Pools and spas
• HVAC
• Commercial ovens
• Lighting
Up to 8 events
3 year alkaline backup
3,600 Watts @ 120V
7,200 Watts @ 240V
120–240V 50/60 Hz
Remote override
capable
• HVAC
• Commercial ovens
• Lighting
• Fans, blowers
and pumps
Up to 8 events
3 year alkaline backup
30 Amp rated
120, 120–277V 50/60 Hz
SPST, SPDT, DPST
contacts
• HVAC
• Lighting
• Fans, blowers
and pumps
• Bells and signals
Up to 20 events
1 or 2 circuit
Pulse option
3 year alkaline backup
30 Amp rated
120 & 240V 50/60 Hz
2 SPST contacts
• HVAC
• Commercial ovens
• Lighting
• Fans, blowers
and pumps
• Bells and signals
Up to 28 events
Ni Cadmium
rechargeable backup
Pulse and photo
sensor models
5 Amps rated for
pilot duty
SPST, DPST Contacts
120V 60 Hz
• Bathroom fans
• Whole house fans
• Ceiling fans
• Fluorescent lights
• Heaters
Countdown or 7 day
programmable
3 year alkaline backup
120–277V 50/60 Hz
12–28 VDC
Single pole, 3 or 4-way
Junction box mounted
Independent control
Lifetime memory with 4,000+ events
Astronomic or pulse programming
20 Amp ballast @ 120–277V
120–277V 50/60 Hz
Remote override
L1
L2
L3
277 VAC
COM
N.C.
CIRCUIT
1
N.O.
NEUTRAL
N.O.
COM
N.O.
COM
CIRCUIT
6
N.O.
COM
N.C.
#1
Neutral
Hot
Timer
Power
1
2
120 VAC
3
Circuit #1
4
5
6
Circuit #2
7
Photo Control
Black
Red
Relay
Coil
White
Astronomic with photo control override
8
3
4
COM
N.C.
N.O.
N.O.
COM
5
#3
CIRCUIT
13
#6
EQUIPMENT
GROUND
CLOSE COM
OPEN
Latching Lighting
Contactor
1
2
CIRCUIT #2
#7
COM
N.C.
N.O.
3
4
5
6
7
8
9
10
11
12
13
14
Control of latching contactor
N.O.
N.O.
CIRCUIT
14
N.C.
COM
N.O.
N.O.
CIRCUIT
16
LINE 2
N.C.
277
240
208
120
LINE 1
LINE 2
TIMER POWER
E
8
1
EQUIP M ENT
GROUN D
TM ER POW ER
120 VAC
OUTDOOR
LIGHTING
INDOOR LIGHTING
AC MOTOR
E
Multi-function
controlling lights, HVAC and signal alarms
NEUTRAL
A
A
Multi-function controlling lights, HVAC and signal alarms
Neutral
H OT
LINE 2
TIMER POWER
240 VAC
Input
INPUT
VOLTAGE
SELECTOR
LINE 1
NEUTRAL
USE 10 TO 16 GUAGE
COPPER W IRE ONL Y
H OT
1
Timer
Power
2
3
LINE 1
Hot
4
5
6
LINE 2
WATER
HTR.
NEUTRAL
Multi-function controlling lights, HVAC and signal alarms
Single 240V water heater control
4
Neutral
E
Hot
LOAD
LINE 2
240 VAC
Input
LINE 1
Timer
Power
1
2
3
LINE 1
Direct 240V load control
Timer
Power
1
2
4
3
E
1
LINE 2
Timer
Power
2
240 VAC
Input
4
LINE 1
120 VAC
Input
5
LINE 2
LOAD
6
LINE 2
240 VAC
Input
LINE 1
3
LINE 1
Direct 240V load control
4
5
6
LINE 2
LOAD
LOAD
Timer
Power
1
2
3
LINE 1
Direct 240V load control
Direct 120V load control
Direct 120V load control
4
5
6
Neutral
1
Timer
Power
2
CIRCUIT 1
3
4
CIRCUIT 2
5
LOAD
Hot
Latching
Relay
277 VAC
LOAD
Latching contactor control
3
4
LOAD
rem
iT
rew
oP
1
2
Direct
120V load control
E
120 VAC
Input
Hot
Timer
Power
2
120 VAC
Input
6
CLOSE COM OPEN
LINE 2
1
Neutral
Neutral
120 VAC
Input
Hot
1
Timer
Power
2
CIRCUIT 1
3
4
5
6
Neutral
120 VAC
Input
Hot
LOAD
1
LOAD
2
Dual load control on separate schedules
Low Voltage
Supply
4
5
4
5
55o
F
6
7
8
40o
F
73o
F
24 VAC
Zone # 1
9
10
11
12 13
60o
F
60o
F
24 VAC
Zone # 2
14
7 8
10 11
120C
VA
tu
p
n
I
24 VAC
Zone # 3
M
Mulitzone
HVAC control
O
L
CE
S
65o
F
24 VAC
Zone # 4
d
aoL
Su
pply
13
COM OP
EN
ctaLhign
yaleR# 1
O
L
C SE COM
ctaLhign
yaleR# 2
O
LD
A
1
Latching contactor control
O
LD
A
2
Timer
Neutral
Blue
or Black
Red
(Cap and do not use.)
Single pole wiring
H
Hot
OP
EN
d
aoL
Su
pply
Black
or Blue
14
120 V
Su
gr e
Su
pprseso
r
Typ. (4)
toH
35o
F
73o
F
Hot
On
slu
Pe
lartu
eN
Timer
Power
1
2
3
CIRCUIT 2
Off slu
Pe
Black
Timer
Install Jumper
Neutral
Blue
Red
Common
Load
3 way wiring
For Hmore information
go to
T
www.intermatic.com/energycontrols
www.intermatic.com/energycontrols
• Copy & paste specifier text
• Competitive comparisons
• Downloadable programming help
and wiring diagrams
3
120 VAC
Input
For more information go to
Certified under Title 24, Part 6, Section 131(D) of the California Code of Regulations
Timer
Power
1
2
Single 120V water heater control
CIRCUIT
10
CIRCUIT
12
HOT
HOT
Outdoor
Lighting
COM
N.C.
N.C.
277
240
208
120
LINE 1
4
WATER
HTR.
N.C.
COM
N.C.
COM
INPUT
VOLTAGE
SELECTOR
USE 10 TO 16
HOT
TIMER
GAUGE COPPER
EQUIPMENT POWER NEUTRAL
WIRE ONLY
120 VAC
GROUND
TO REMOTE
SWITCH(S)
NEUTRAL
277 VAC
N.O.
COM
#8
Hot
N.O.
120 VAC
Neutral
CIRCUIT
15
N.C.
CIRCUIT #4
CIRCUIT #3
3
120 VAC
Input
N.C.
COM
N.C.
N.O.
COM
N.O.
N.O.
CIRCUIT #1
TIMER
POWER
N.O.
COM
N.C.
COM
N.C.
COM
Neutral
120
VAC
Hot
Neutral
Timer
Power
2
N.C.
COM
N.C.
CIRCUIT
9
N.O.
CIRCUIT
11
1
CIRCUIT
8
N.O.
COM
TO REMOTE
SWITCH(S)
#4
N.O.
N.O.
COM
#5
#2
N.C.
COM
N.C.
Allows for easy input of complex programs
via a graphical user interface on your PC.
Uses interface hardware shown above.
Coming soon.
COM
N.C.
CIRCUIT
7
N.O.
Circuit #1
CIRCUIT
4
N.C.
COM
N.C.
CIRCUIT
5
N.O.
Timer
Power
1
2
CIRCUIT
2
N.C.
COM
N.C.
CIRCUIT
3
N.O.
Latching contactor with pulse output
PC NETWORK CONNECTION
C
US
*Certified under Title 24, Part 6, Section 131(D) of the California Code of Regulations
• Copy & paste specifier text
• Competitive comparisons
• Downloadable programming help
and wiring diagrams
D
Next Generation
First Generation
ELECTRONIC TIME SWITCHES
ELECTRONIC TIME SWITCHES
Factory
Pre-Programming
Pre-installation of your
specific program requirements
available on quantity orders
of 50 + (ET70000CR Series.)
EI20C
ET279C *
ET70215C & ET70215CR
ET70115C & ET70115CR
ET70415CR
ET70815CR
New Connectivity Features
Full Year
Water Heater 7 day
ET100C SERIES
EP100C SERIES
EH10 / EH40
ET71615CR
Low Cost 24hr. with 3R
ET170C SERIES *
7 Day
24 Hour
EI40C
ET700C SERIES *
7 Day with Features
In Wall
Remote override for
1 and 2 circuit
FOR CONTROLLING
• Water heaters
• HVAC
• Commercial ovens
• Lighting
• Fans, blowers and
pumps
• Bells and signals
• Process equipment
• Poultry equipment
• Livestock feeders
NEMA 1 installation with
surface mount junction box
RS232 Interface
NEMA 3R installation with
flush or raintight junction box
SPECIFICATIONS
SPECIFICATIONS
1 or 2 circuit
SPECIFICATIONS
4 circuit
NEMA 3R enclosure option
Lifetime memory with 1,000+ events
Astronomic or pulse programming
20 Amp ballast @ 120–277V
120–277V 50/60 Hz
SPDT contacts
Remote override option
CIRCUIT #1
CIRCUIT #2
TIMER
POWER
EQUIPMENT
GROUND
1
2
3
4
5
6
7
8
NEUTRAL
277 VAC
CLOSE
HOT
COM
OPEN
Latching
Relay
OUTDOOR
LIGHTING
8 circuit
Independent control
Lifetime memory with 1,000+ events
Astronomic or pulse programming
20 Amp ballast @ 120–277V
120–277V input 50/60 Hz
Remote override
E
Independent control
Lifetime memory with 4,000+ events
Astronomic or pulse programming
20 Amp ballast @ 120–277V
120–277V 50/60 Hz
Remote override
SPECIFICATIONS
REMOTE OVERRIDE
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
16 circuit
Allows for manual control of loads using
remotely-located switches (up to 1,000 ft.
from time switch). Uses interface hardware
shown above. For 1 and 2 circuit.
• Residential
• Commercial,
industrial,
institutional and
military facilities
Up to 12 events
3 year alkaline backup
3,600 Watts @ 120V
7,200 Watts @ 240V
120–240V 50/60 Hz
• Pools and spas
• HVAC
• Commercial ovens
• Lighting
Up to 8 events
3 year alkaline backup
3,600 Watts @ 120V
7,200 Watts @ 240V
120–240V 50/60 Hz
Remote override
capable
• HVAC
• Commercial ovens
• Lighting
• Fans, blowers
and pumps
Up to 8 events
3 year alkaline backup
30 Amp rated
120, 120–277V 50/60 Hz
SPST, SPDT, DPST
contacts
• HVAC
• Lighting
• Fans, blowers
and pumps
• Bells and signals
Up to 20 events
1 or 2 circuit
Pulse option
3 year alkaline backup
30 Amp rated
120 & 240V 50/60 Hz
2 SPST contacts
• HVAC
• Commercial ovens
• Lighting
• Fans, blowers
and pumps
• Bells and signals
Up to 28 events
Ni Cadmium
rechargeable backup
Pulse and photo
sensor models
5 Amps rated for
pilot duty
SPST, DPST Contacts
120V 60 Hz
• Bathroom fans
• Whole house fans
• Ceiling fans
• Fluorescent lights
• Heaters
Countdown or 7 day
programmable
3 year alkaline backup
120–277V 50/60 Hz
12–28 VDC
Single pole, 3 or 4-way
Junction box mounted
Independent control
Lifetime memory with 4,000+ events
Astronomic or pulse programming
20 Amp ballast @ 120–277V
120–277V 50/60 Hz
Remote override
L1
L2
L3
277 VAC
COM
N.C.
CIRCUIT
1
N.O.
NEUTRAL
N.O.
COM
N.O.
COM
CIRCUIT
6
N.O.
COM
N.C.
#1
Neutral
Hot
Timer
Power
1
2
120 VAC
3
Circuit #1
4
5
6
Circuit #2
7
Photo Control
Black
Red
Relay
Coil
White
Astronomic with photo control override
8
3
4
COM
N.C.
N.O.
N.O.
COM
5
#3
CIRCUIT
13
#6
EQUIPMENT
GROUND
CLOSE COM
OPEN
Latching Lighting
Contactor
1
2
CIRCUIT #2
#7
COM
N.C.
N.O.
3
4
5
6
7
8
9
10
11
12
13
14
Control of latching contactor
N.O.
N.O.
CIRCUIT
14
N.C.
COM
N.O.
N.O.
CIRCUIT
16
LINE 2
N.C.
277
240
208
120
LINE 1
LINE 2
TIMER POWER
E
8
1
EQUIP M ENT
GROUN D
TM ER POW ER
120 VAC
OUTDOOR
LIGHTING
INDOOR LIGHTING
AC MOTOR
E
Multi-function
controlling lights, HVAC and signal alarms
NEUTRAL
A
A
Multi-function controlling lights, HVAC and signal alarms
Neutral
H OT
LINE 2
TIMER POWER
240 VAC
Input
INPUT
VOLTAGE
SELECTOR
LINE 1
NEUTRAL
USE 10 TO 16 GUAGE
COPPER W IRE ONL Y
H OT
1
Timer
Power
2
3
LINE 1
Hot
4
5
6
LINE 2
WATER
HTR.
NEUTRAL
Multi-function controlling lights, HVAC and signal alarms
Single 240V water heater control
4
Neutral
E
Hot
LOAD
LINE 2
240 VAC
Input
LINE 1
Timer
Power
1
2
3
LINE 1
Direct 240V load control
Timer
Power
1
2
4
3
E
1
LINE 2
Timer
Power
2
240 VAC
Input
4
LINE 1
120 VAC
Input
5
LINE 2
LOAD
6
LINE 2
240 VAC
Input
LINE 1
3
LINE 1
Direct 240V load control
4
5
6
LINE 2
LOAD
LOAD
Timer
Power
1
2
3
LINE 1
Direct 240V load control
Direct 120V load control
Direct 120V load control
4
5
6
Neutral
1
Timer
Power
2
CIRCUIT 1
3
4
CIRCUIT 2
5
LOAD
Hot
Latching
Relay
277 VAC
LOAD
Latching contactor control
3
4
LOAD
rem
iT
rew
oP
1
2
Direct
120V load control
E
120 VAC
Input
Hot
Timer
Power
2
120 VAC
Input
6
CLOSE COM OPEN
LINE 2
1
Neutral
Neutral
120 VAC
Input
Hot
1
Timer
Power
2
CIRCUIT 1
3
4
5
6
Neutral
120 VAC
Input
Hot
LOAD
1
LOAD
2
Dual load control on separate schedules
Low Voltage
Supply
4
5
4
5
55o
F
6
7
8
40o
F
73o
F
24 VAC
Zone # 1
9
10
11
12 13
60o
F
60o
F
24 VAC
Zone # 2
14
7 8
10 11
120C
VA
tu
p
n
I
24 VAC
Zone # 3
M
Mulitzone
HVAC control
O
L
CE
S
65o
F
24 VAC
Zone # 4
d
aoL
Su
pply
13
COM OP
EN
ctaLhign
yaleR# 1
O
L
C SE COM
ctaLhign
yaleR# 2
O
LD
A
1
Latching contactor control
O
LD
A
2
Timer
Neutral
Blue
or Black
Red
(Cap and do not use.)
Single pole wiring
H
Hot
OP
EN
d
aoL
Su
pply
Black
or Blue
14
120 V
Su
gr e
Su
pprseso
r
Typ. (4)
toH
35o
F
73o
F
Hot
On
slu
Pe
lartu
eN
Timer
Power
1
2
3
CIRCUIT 2
Off slu
Pe
Black
Timer
Install Jumper
Neutral
Blue
Red
Common
Load
3 way wiring
For Hmore information
go to
T
www.intermatic.com/energycontrols
www.intermatic.com/energycontrols
• Copy & paste specifier text
• Competitive comparisons
• Downloadable programming help
and wiring diagrams
3
120 VAC
Input
For more information go to
Certified under Title 24, Part 6, Section 131(D) of the California Code of Regulations
Timer
Power
1
2
Single 120V water heater control
CIRCUIT
10
CIRCUIT
12
HOT
HOT
Outdoor
Lighting
COM
N.C.
N.C.
277
240
208
120
LINE 1
4
WATER
HTR.
N.C.
COM
N.C.
COM
INPUT
VOLTAGE
SELECTOR
USE 10 TO 16
HOT
TIMER
GAUGE COPPER
EQUIPMENT POWER NEUTRAL
WIRE ONLY
120 VAC
GROUND
TO REMOTE
SWITCH(S)
NEUTRAL
277 VAC
N.O.
COM
#8
Hot
N.O.
120 VAC
Neutral
CIRCUIT
15
N.C.
CIRCUIT #4
CIRCUIT #3
3
120 VAC
Input
N.C.
COM
N.C.
N.O.
COM
N.O.
N.O.
CIRCUIT #1
TIMER
POWER
N.O.
COM
N.C.
COM
N.C.
COM
Neutral
120
VAC
Hot
Neutral
Timer
Power
2
N.C.
COM
N.C.
CIRCUIT
9
N.O.
CIRCUIT
11
1
CIRCUIT
8
N.O.
COM
TO REMOTE
SWITCH(S)
#4
N.O.
N.O.
COM
#5
#2
N.C.
COM
N.C.
Allows for easy input of complex programs
via a graphical user interface on your PC.
Uses interface hardware shown above.
Coming soon.
COM
N.C.
CIRCUIT
7
N.O.
Circuit #1
CIRCUIT
4
N.C.
COM
N.C.
CIRCUIT
5
N.O.
Timer
Power
1
2
CIRCUIT
2
N.C.
COM
N.C.
CIRCUIT
3
N.O.
Latching contactor with pulse output
PC NETWORK CONNECTION
C
US
*Certified under Title 24, Part 6, Section 131(D) of the California Code of Regulations
• Copy & paste specifier text
• Competitive comparisons
• Downloadable programming help
and wiring diagrams
D
Next Generation
First Generation
ELECTRONIC TIME SWITCHES
ELECTRONIC TIME SWITCHES
Factory
Pre-Programming
Pre-installation of your
specific program requirements
available on quantity orders
of 50 + (ET70000CR Series.)
EI20C
ET279C *
ET70215C & ET70215CR
ET70115C & ET70115CR
ET70415CR
ET70815CR
New Connectivity Features
Full Year
Water Heater 7 day
ET100C SERIES
EP100C SERIES
EH10 / EH40
ET71615CR
Low Cost 24hr. with 3R
ET170C SERIES *
7 Day
24 Hour
EI40C
ET700C SERIES *
7 Day with Features
In Wall
Remote override for
1 and 2 circuit
FOR CONTROLLING
• Water heaters
• HVAC
• Commercial ovens
• Lighting
• Fans, blowers and
pumps
• Bells and signals
• Process equipment
• Poultry equipment
• Livestock feeders
NEMA 1 installation with
surface mount junction box
RS232 Interface
NEMA 3R installation with
flush or raintight junction box
SPECIFICATIONS
SPECIFICATIONS
1 or 2 circuit
SPECIFICATIONS
4 circuit
NEMA 3R enclosure option
Lifetime memory with 1,000+ events
Astronomic or pulse programming
20 Amp ballast @ 120–277V
120–277V 50/60 Hz
SPDT contacts
Remote override option
CIRCUIT #1
CIRCUIT #2
TIMER
POWER
EQUIPMENT
GROUND
1
2
3
4
5
6
7
8
NEUTRAL
277 VAC
CLOSE
HOT
COM
OPEN
Latching
Relay
OUTDOOR
LIGHTING
8 circuit
Independent control
Lifetime memory with 1,000+ events
Astronomic or pulse programming
20 Amp ballast @ 120–277V
120–277V input 50/60 Hz
Remote override
E
Independent control
Lifetime memory with 4,000+ events
Astronomic or pulse programming
20 Amp ballast @ 120–277V
120–277V 50/60 Hz
Remote override
SPECIFICATIONS
REMOTE OVERRIDE
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
16 circuit
Allows for manual control of loads using
remotely-located switches (up to 1,000 ft.
from time switch). Uses interface hardware
shown above. For 1 and 2 circuit.
• Residential
• Commercial,
industrial,
institutional and
military facilities
Up to 12 events
3 year alkaline backup
3,600 Watts @ 120V
7,200 Watts @ 240V
120–240V 50/60 Hz
• Pools and spas
• HVAC
• Commercial ovens
• Lighting
Up to 8 events
3 year alkaline backup
3,600 Watts @ 120V
7,200 Watts @ 240V
120–240V 50/60 Hz
Remote override
capable
• HVAC
• Commercial ovens
• Lighting
• Fans, blowers
and pumps
Up to 8 events
3 year alkaline backup
30 Amp rated
120, 120–277V 50/60 Hz
SPST, SPDT, DPST
contacts
• HVAC
• Lighting
• Fans, blowers
and pumps
• Bells and signals
Up to 20 events
1 or 2 circuit
Pulse option
3 year alkaline backup
30 Amp rated
120 & 240V 50/60 Hz
2 SPST contacts
• HVAC
• Commercial ovens
• Lighting
• Fans, blowers
and pumps
• Bells and signals
Up to 28 events
Ni Cadmium
rechargeable backup
Pulse and photo
sensor models
5 Amps rated for
pilot duty
SPST, DPST Contacts
120V 60 Hz
• Bathroom fans
• Whole house fans
• Ceiling fans
• Fluorescent lights
• Heaters
Countdown or 7 day
programmable
3 year alkaline backup
120–277V 50/60 Hz
12–28 VDC
Single pole, 3 or 4-way
Junction box mounted
Independent control
Lifetime memory with 4,000+ events
Astronomic or pulse programming
20 Amp ballast @ 120–277V
120–277V 50/60 Hz
Remote override
L1
L2
L3
277 VAC
COM
N.C.
CIRCUIT
1
N.O.
NEUTRAL
N.O.
COM
N.O.
COM
CIRCUIT
6
N.O.
COM
N.C.
#1
Neutral
Hot
Timer
Power
1
2
120 VAC
3
Circuit #1
4
5
6
Circuit #2
7
Photo Control
Black
Red
Relay
Coil
White
Astronomic with photo control override
8
3
4
COM
N.C.
N.O.
N.O.
COM
5
#3
CIRCUIT
13
#6
EQUIPMENT
GROUND
CLOSE COM
OPEN
Latching Lighting
Contactor
1
2
CIRCUIT #2
#7
COM
N.C.
N.O.
3
4
5
6
7
8
9
10
11
12
13
14
Control of latching contactor
N.O.
N.O.
CIRCUIT
14
N.C.
COM
N.O.
N.O.
CIRCUIT
16
LINE 2
N.C.
277
240
208
120
LINE 1
LINE 2
TIMER POWER
E
8
1
EQUIP M ENT
GROUN D
TM ER POW ER
120 VAC
OUTDOOR
LIGHTING
INDOOR LIGHTING
AC MOTOR
E
Multi-function
controlling lights, HVAC and signal alarms
NEUTRAL
A
A
Multi-function controlling lights, HVAC and signal alarms
Neutral
H OT
LINE 2
TIMER POWER
240 VAC
Input
INPUT
VOLTAGE
SELECTOR
LINE 1
NEUTRAL
USE 10 TO 16 GUAGE
COPPER W IRE ONL Y
H OT
1
Timer
Power
2
3
LINE 1
Hot
4
5
6
LINE 2
WATER
HTR.
NEUTRAL
Multi-function controlling lights, HVAC and signal alarms
Single 240V water heater control
4
Neutral
E
Hot
LOAD
LINE 2
240 VAC
Input
LINE 1
Timer
Power
1
2
3
LINE 1
Direct 240V load control
Timer
Power
1
2
4
3
E
1
LINE 2
Timer
Power
2
240 VAC
Input
4
LINE 1
120 VAC
Input
5
LINE 2
LOAD
6
LINE 2
240 VAC
Input
LINE 1
3
LINE 1
Direct 240V load control
4
5
6
LINE 2
LOAD
LOAD
Timer
Power
1
2
3
LINE 1
Direct 240V load control
Direct 120V load control
Direct 120V load control
4
5
6
Neutral
1
Timer
Power
2
CIRCUIT 1
3
4
CIRCUIT 2
5
LOAD
Hot
Latching
Relay
277 VAC
LOAD
Latching contactor control
3
4
LOAD
rem
iT
rew
oP
1
2
Direct
120V load control
E
120 VAC
Input
Hot
Timer
Power
2
120 VAC
Input
6
CLOSE COM OPEN
LINE 2
1
Neutral
Neutral
120 VAC
Input
Hot
1
Timer
Power
2
CIRCUIT 1
3
4
5
6
Neutral
120 VAC
Input
Hot
LOAD
1
LOAD
2
Dual load control on separate schedules
Low Voltage
Supply
4
5
4
5
55o
F
6
7
8
40o
F
73o
F
24 VAC
Zone # 1
9
10
11
12 13
60o
F
60o
F
24 VAC
Zone # 2
14
7 8
10 11
120C
VA
tu
p
n
I
24 VAC
Zone # 3
M
Mulitzone
HVAC control
O
L
CE
S
65o
F
24 VAC
Zone # 4
d
aoL
Su
pply
13
COM OP
EN
ctaLhign
yaleR# 1
O
L
C SE COM
ctaLhign
yaleR# 2
O
LD
A
1
Latching contactor control
O
LD
A
2
Timer
Neutral
Blue
or Black
Red
(Cap and do not use.)
Single pole wiring
H
Hot
OP
EN
d
aoL
Su
pply
Black
or Blue
14
120 V
Su
gr e
Su
pprseso
r
Typ. (4)
toH
35o
F
73o
F
Hot
On
slu
Pe
lartu
eN
Timer
Power
1
2
3
CIRCUIT 2
Off slu
Pe
Black
Timer
Install Jumper
Neutral
Blue
Red
Common
Load
3 way wiring
For Hmore information
go to
T
www.intermatic.com/energycontrols
www.intermatic.com/energycontrols
• Copy & paste specifier text
• Competitive comparisons
• Downloadable programming help
and wiring diagrams
3
120 VAC
Input
For more information go to
Certified under Title 24, Part 6, Section 131(D) of the California Code of Regulations
Timer
Power
1
2
Single 120V water heater control
CIRCUIT
10
CIRCUIT
12
HOT
HOT
Outdoor
Lighting
COM
N.C.
N.C.
277
240
208
120
LINE 1
4
WATER
HTR.
N.C.
COM
N.C.
COM
INPUT
VOLTAGE
SELECTOR
USE 10 TO 16
HOT
TIMER
GAUGE COPPER
EQUIPMENT POWER NEUTRAL
WIRE ONLY
120 VAC
GROUND
TO REMOTE
SWITCH(S)
NEUTRAL
277 VAC
N.O.
COM
#8
Hot
N.O.
120 VAC
Neutral
CIRCUIT
15
N.C.
CIRCUIT #4
CIRCUIT #3
3
120 VAC
Input
N.C.
COM
N.C.
N.O.
COM
N.O.
N.O.
CIRCUIT #1
TIMER
POWER
N.O.
COM
N.C.
COM
N.C.
COM
Neutral
120
VAC
Hot
Neutral
Timer
Power
2
N.C.
COM
N.C.
CIRCUIT
9
N.O.
CIRCUIT
11
1
CIRCUIT
8
N.O.
COM
TO REMOTE
SWITCH(S)
#4
N.O.
N.O.
COM
#5
#2
N.C.
COM
N.C.
Allows for easy input of complex programs
via a graphical user interface on your PC.
Uses interface hardware shown above.
Coming soon.
COM
N.C.
CIRCUIT
7
N.O.
Circuit #1
CIRCUIT
4
N.C.
COM
N.C.
CIRCUIT
5
N.O.
Timer
Power
1
2
CIRCUIT
2
N.C.
COM
N.C.
CIRCUIT
3
N.O.
Latching contactor with pulse output
PC NETWORK CONNECTION
C
US
*Certified under Title 24, Part 6, Section 131(D) of the California Code of Regulations
• Copy & paste specifier text
• Competitive comparisons
• Downloadable programming help
and wiring diagrams
D
Next Generation
First Generation
ELECTRONIC TIME SWITCHES
ELECTRONIC TIME SWITCHES
Factory
Pre-Programming
Pre-installation of your
specific program requirements
available on quantity orders
of 50 + (ET70000CR Series.)
EI20C
ET279C *
ET70215C & ET70215CR
ET70115C & ET70115CR
ET70415CR
ET70815CR
New Connectivity Features
Full Year
Water Heater 7 day
ET100C SERIES
EP100C SERIES
EH10 / EH40
ET71615CR
Low Cost 24hr. with 3R
ET170C SERIES *
7 Day
24 Hour
EI40C
ET700C SERIES *
7 Day with Features
In Wall
Remote override for
1 and 2 circuit
FOR CONTROLLING
• Water heaters
• HVAC
• Commercial ovens
• Lighting
• Fans, blowers and
pumps
• Bells and signals
• Process equipment
• Poultry equipment
• Livestock feeders
NEMA 1 installation with
surface mount junction box
RS232 Interface
NEMA 3R installation with
flush or raintight junction box
SPECIFICATIONS
SPECIFICATIONS
1 or 2 circuit
SPECIFICATIONS
4 circuit
NEMA 3R enclosure option
Lifetime memory with 1,000+ events
Astronomic or pulse programming
20 Amp ballast @ 120–277V
120–277V 50/60 Hz
SPDT contacts
Remote override option
CIRCUIT #1
CIRCUIT #2
TIMER
POWER
EQUIPMENT
GROUND
1
2
3
4
5
6
7
8
NEUTRAL
277 VAC
CLOSE
HOT
COM
OPEN
Latching
Relay
OUTDOOR
LIGHTING
8 circuit
Independent control
Lifetime memory with 1,000+ events
Astronomic or pulse programming
20 Amp ballast @ 120–277V
120–277V input 50/60 Hz
Remote override
E
Independent control
Lifetime memory with 4,000+ events
Astronomic or pulse programming
20 Amp ballast @ 120–277V
120–277V 50/60 Hz
Remote override
SPECIFICATIONS
REMOTE OVERRIDE
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
FOR CONTROLLING
SPECIFICATIONS
16 circuit
Allows for manual control of loads using
remotely-located switches (up to 1,000 ft.
from time switch). Uses interface hardware
shown above. For 1 and 2 circuit.
• Residential
• Commercial,
industrial,
institutional and
military facilities
Up to 12 events
3 year alkaline backup
3,600 Watts @ 120V
7,200 Watts @ 240V
120–240V 50/60 Hz
• Pools and spas
• HVAC
• Commercial ovens
• Lighting
Up to 8 events
3 year alkaline backup
3,600 Watts @ 120V
7,200 Watts @ 240V
120–240V 50/60 Hz
Remote override
capable
• HVAC
• Commercial ovens
• Lighting
• Fans, blowers
and pumps
Up to 8 events
3 year alkaline backup
30 Amp rated
120, 120–277V 50/60 Hz
SPST, SPDT, DPST
contacts
• HVAC
• Lighting
• Fans, blowers
and pumps
• Bells and signals
Up to 20 events
1 or 2 circuit
Pulse option
3 year alkaline backup
30 Amp rated
120 & 240V 50/60 Hz
2 SPST contacts
• HVAC
• Commercial ovens
• Lighting
• Fans, blowers
and pumps
• Bells and signals
Up to 28 events
Ni Cadmium
rechargeable backup
Pulse and photo
sensor models
5 Amps rated for
pilot duty
SPST, DPST Contacts
120V 60 Hz
• Bathroom fans
• Whole house fans
• Ceiling fans
• Fluorescent lights
• Heaters
Countdown or 7 day
programmable
3 year alkaline backup
120–277V 50/60 Hz
12–28 VDC
Single pole, 3 or 4-way
Junction box mounted
Independent control
Lifetime memory with 4,000+ events
Astronomic or pulse programming
20 Amp ballast @ 120–277V
120–277V 50/60 Hz
Remote override
L1
L2
L3
277 VAC
COM
N.C.
CIRCUIT
1
N.O.
NEUTRAL
N.O.
COM
N.O.
COM
CIRCUIT
6
N.O.
COM
N.C.
#1
Neutral
Hot
Timer
Power
1
2
120 VAC
3
Circuit #1
4
5
6
Circuit #2
7
Photo Control
Black
Red
Relay
Coil
White
Astronomic with photo control override
8
3
4
COM
N.C.
N.O.
N.O.
COM
5
#3
CIRCUIT
13
#6
EQUIPMENT
GROUND
CLOSE COM
OPEN
Latching Lighting
Contactor
1
2
CIRCUIT #2
#7
COM
N.C.
N.O.
3
4
5
6
7
8
9
10
11
12
13
14
Control of latching contactor
N.O.
N.O.
CIRCUIT
14
N.C.
COM
N.O.
N.O.
CIRCUIT
16
LINE 2
N.C.
277
240
208
120
LINE 1
LINE 2
TIMER POWER
E
8
1
EQUIP M ENT
GROUN D
TM ER POW ER
120 VAC
OUTDOOR
LIGHTING
INDOOR LIGHTING
AC MOTOR
E
Multi-function
controlling lights, HVAC and signal alarms
NEUTRAL
A
A
Multi-function controlling lights, HVAC and signal alarms
Neutral
H OT
LINE 2
TIMER POWER
240 VAC
Input
INPUT
VOLTAGE
SELECTOR
LINE 1
NEUTRAL
USE 10 TO 16 GUAGE
COPPER W IRE ONL Y
H OT
1
Timer
Power
2
3
LINE 1
Hot
4
5
6
LINE 2
WATER
HTR.
NEUTRAL
Multi-function controlling lights, HVAC and signal alarms
Single 240V water heater control
4
Neutral
E
Hot
LOAD
LINE 2
240 VAC
Input
LINE 1
Timer
Power
1
2
3
LINE 1
Direct 240V load control
Timer
Power
1
2
4
3
E
1
LINE 2
Timer
Power
2
240 VAC
Input
4
LINE 1
120 VAC
Input
5
LINE 2
LOAD
6
LINE 2
240 VAC
Input
LINE 1
3
LINE 1
Direct 240V load control
4
5
6
LINE 2
LOAD
LOAD
Timer
Power
1
2
3
LINE 1
Direct 240V load control
Direct 120V load control
Direct 120V load control
4
5
6
Neutral
1
Timer
Power
2
CIRCUIT 1
3
4
CIRCUIT 2
5
LOAD
Hot
Latching
Relay
277 VAC
LOAD
Latching contactor control
3
4
LOAD
rem
iT
rew
oP
1
2
Direct
120V load control
E
120 VAC
Input
Hot
Timer
Power
2
120 VAC
Input
6
CLOSE COM OPEN
LINE 2
1
Neutral
Neutral
120 VAC
Input
Hot
1
Timer
Power
2
CIRCUIT 1
3
4
5
6
Neutral
120 VAC
Input
Hot
LOAD
1
LOAD
2
Dual load control on separate schedules
Low Voltage
Supply
4
5
4
5
55o
F
6
7
8
40o
F
73o
F
24 VAC
Zone # 1
9
10
11
12 13
60o
F
60o
F
24 VAC
Zone # 2
14
7 8
10 11
120C
VA
tu
p
n
I
24 VAC
Zone # 3
M
Mulitzone
HVAC control
O
L
CE
S
65o
F
24 VAC
Zone # 4
d
aoL
Su
pply
13
COM OP
EN
ctaLhign
yaleR# 1
O
L
C SE COM
ctaLhign
yaleR# 2
O
LD
A
1
Latching contactor control
O
LD
A
2
Timer
Neutral
Blue
or Black
Red
(Cap and do not use.)
Single pole wiring
H
Hot
OP
EN
d
aoL
Su
pply
Black
or Blue
14
120 V
Su
gr e
Su
pprseso
r
Typ. (4)
toH
35o
F
73o
F
Hot
On
slu
Pe
lartu
eN
Timer
Power
1
2
3
CIRCUIT 2
Off slu
Pe
Black
Timer
Install Jumper
Neutral
Blue
Red
Common
Load
3 way wiring
For Hmore information
go to
T
www.intermatic.com/energycontrols
www.intermatic.com/energycontrols
• Copy & paste specifier text
• Competitive comparisons
• Downloadable programming help
and wiring diagrams
3
120 VAC
Input
For more information go to
Certified under Title 24, Part 6, Section 131(D) of the California Code of Regulations
Timer
Power
1
2
Single 120V water heater control
CIRCUIT
10
CIRCUIT
12
HOT
HOT
Outdoor
Lighting
COM
N.C.
N.C.
277
240
208
120
LINE 1
4
WATER
HTR.
N.C.
COM
N.C.
COM
INPUT
VOLTAGE
SELECTOR
USE 10 TO 16
HOT
TIMER
GAUGE COPPER
EQUIPMENT POWER NEUTRAL
WIRE ONLY
120 VAC
GROUND
TO REMOTE
SWITCH(S)
NEUTRAL
277 VAC
N.O.
COM
#8
Hot
N.O.
120 VAC
Neutral
CIRCUIT
15
N.C.
CIRCUIT #4
CIRCUIT #3
3
120 VAC
Input
N.C.
COM
N.C.
N.O.
COM
N.O.
N.O.
CIRCUIT #1
TIMER
POWER
N.O.
COM
N.C.
COM
N.C.
COM
Neutral
120
VAC
Hot
Neutral
Timer
Power
2
N.C.
COM
N.C.
CIRCUIT
9
N.O.
CIRCUIT
11
1
CIRCUIT
8
N.O.
COM
TO REMOTE
SWITCH(S)
#4
N.O.
N.O.
COM
#5
#2
N.C.
COM
N.C.
Allows for easy input of complex programs
via a graphical user interface on your PC.
Uses interface hardware shown above.
Coming soon.
COM
N.C.
CIRCUIT
7
N.O.
Circuit #1
CIRCUIT
4
N.C.
COM
N.C.
CIRCUIT
5
N.O.
Timer
Power
1
2
CIRCUIT
2
N.C.
COM
N.C.
CIRCUIT
3
N.O.
Latching contactor with pulse output
PC NETWORK CONNECTION
C
US
*Certified under Title 24, Part 6, Section 131(D) of the California Code of Regulations
• Copy & paste specifier text
• Competitive comparisons
• Downloadable programming help
and wiring diagrams
D
First Generation
Next Generation
ELECTRONIC TIME SWITCHES
ELECTRONIC TIME SWITCHES
ELECTRONIC TIME SWITCHES
Full Year
ET70115C
ET70115CR
ET70215C
ET70215CR
Independent Circuit(s)
1
Switch
SPDT
Programming Events (minimum)
1,000
Astro (sunrise/sunset)**
•
•
Pulse (momentary 1 to 127 sec.)**
Interval (time of day)**
•
Interval (user selectable override)**
Remote†††
Holiday Programming (up to 99)
•
Holiday Duration (any length)
•
Auto Daylight Savings Adjustment
•
Lifetime Memory for Program Data
•
8-Year Battery Backup Timekeeping
•
Isolated Logic Board/6,000V Transient Protection
•
Power Input 120/208/240/277 VAC 50/60Hz
•
Power Input 24 VAC 60 Hz (add “24” suffix)
20
Amps (general purpose) 12–277V†
20
Amps ballast 120–277V†
2/1
HP 240V† / HP 120V†
5
Amps Tungsten/TV 120–240V†
470VA
Pilot Duty 12–240V†
Lockable Steel Enclosure
NEMA 1
1
SPDT
1,000
•
•
•
Remote†††
•
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
2
SPDT
1,000
•
•
•
Remote†††
•
•
•
•
•
•
•
2
SPDT
1,000
•
•
•
Remote†††
•
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
Next Generation
20
20
2/1
5
470VA
NEMA 1
ET70415CR‡ ET70815CR‡ ET71615CR‡
4
SPDT
1,000
•
•
•
Remote††
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
8
SPDT
4,000
•
•
•
Remote††
•
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
16
SPDT
4,000
•
•
•
Remote††
•
•
•
•
•
•
•
•
20
20
2/1
5
470VA
NEMA 3R
* Depends on data entry type **All circuits, independently programmable †Switch ratings per pole–normally open contacts
††
Includes remote override for 4 circuits (up to 1,000 ft. away). To expand to max. # of circuits, order accessory #156ET9402A for ET70815CR or #156ET9403A for ET71615CR.
†††
For remote override, order accessory #ET7232M (flush or raintight) or #ET7232M1 (surface mount).
First Generation
Independent Circuit(s)
Switch
Power Input
Program Events
3-Year Battery Backup
Amps
HP 240V (Watts)
HP 120V (Watts)
Enclosure
Water Heater
EH10
EH40
1
SPST
120V
12
•
30
(3600)
NEMA 1
1
DPST
240V
12
•
30
(7200)
NEMA 1
Low Cost 24 Hour w/ 3R
EP101CP3
EP104CP3
1
SPST
120V
8
•
30
2
1
NEMA 3R
1
DPST
240V
8
•
30
2
1
NEMA 3R
24 Hour
ET100C
ET101C
ET102C
ET103C
ET104C
ET105C
1
SPST
120V
8
•
30
2
1
NEMA 1
1
SPST
120V
8
•
30
2
1
NEMA 1
1
SPST
120–277V
8
•
30
2
1
NEMA 1
1
DPST
120V
8
•
30
2
1
NEMA 1
1
DPST
120–277V
8
•
30
2
1
NEMA 1
1
SPDT
120V
8
•
30
2
1
NEMA 1
7 Day
First Generation
THE ULTIMATE IN APPLICATION-SPECIFIC CONTROL
Our first generation of electronic time switches provides
dependable, to-the-minute control and reduced energy costs for a
wide variety of basic applications. As a snap-in upgrade or for new
installations, these models offer ease of programming and a 3-year
battery backup, at a modest cost compared to mechanical time
switches.
STANDARD FEATURES
• To-the-minute programming
• Up to 28 set points
• 3 year battery backup
• Slide switch or push-button programming
• 120, 240 or 277V input
• 1 and 2 circuit models
Independent Circuit(s)
Switch
Power Input
Special Features
Program Events*
Battery Backup
Amps
HP 240V†
HP 120V†
Enclosure
Inwall
7 Day/24 hr
7 Day with Features
ET171C ET171CR E173C
E174C ET175C ET279C
1
SPST
120V
1
DPST
240V
1
SPST
120V
1
DPST
120V
1
SPDT
120V
2
SPST
120V
ET715C ET718C ET728C
1
SPST
120V
Pulse Output
1
4PDT
120V
1
4PDT
120V
ET799C ET716CK EI20 /EI40
1
2PST
120V
SM Series Lighting Control Panels provide control for billboards or other lighting control applications. They include an electronic or mechanical time switch, a main disconnect and up to nine
20 Amp 120V breakers. One and two circuit models are available as are photo control, lightning
arrestor and stainless enclosure options. Request Form # 300SM10001 for more information.
CONTROL
JUST ABOUT
E V E RY T H I N G
1
DPDT
1
SP & 3 way
120/240/277V 12–277V
Multi-Zone Soft Start Pulse Output Photo Sensor Prog./Countdown
20
20
20
20
20
20
28
28
28
28
3 yr
3 yr
3 yr
3 yr
3 yr
3 yr
5 yr
5 yr
5 yr
5 yr
30
30
30
30
30
30
5
5
5
5
2
2
2
2
2
2
1
1
1
1
1
1
NEMA 1 NEMA 3R NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1
Lighting Control Panels
ELECTRONIC TIME SWITCHES
28
5 yr
5
6/NA
3 yr
16
2
1
NEMA 1 wall mount
Intermatic Incorporated
Spring Grove, Illinois 60081-9698
www.intermatic.com
www.energycontrols.com
©2002 Intermatic, Inc.
Printed in U.S.A. 300ET10011
THE ULTIMATE IN APPLICATION-SPECIFIC CONTROL
The Next Generation design is the result of a collaboration of
electrical contractors, engineers, distributors and product
designers. . .backed by the control expertise of the world's leading
time switch manufacturer. These microprocessor-controlled models
offer the ultimate in control and application flexibility. New remote
override and network connection options move the Next Generation
even further ahead of the competition.
www.intermatic.com/energycontrols
STANDARD FEATURES
• Daily, weekly or yearly scheduling
• Fixed, astro, pulse and interval
• Holiday programming (to 99 schedules)
• Lifetime memory for program data
• 8 year battery maintains timekeeping
• 120, 208, 240 or 277V input
• 1, 2, 4, 8 and 16 circuit models
• Auto review for easy program review,
with help messages for omissions.
Was this manual useful for you? yes no