FUJITSU XG2000, C, CR network switch User's Guide
Below you will find brief information for network switch XG2000 XG2000, network switch XG2000 XG2000C, network switch XG2000 XG2000CR. This guide provides a comprehensive overview of the XG2000 series, a compact, 20-port 10 Gigabit Ethernet layer 2 switch, covering its functions, installation procedures, configuration operations, and maintenance procedures.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
XG2000 series
User's Guide
P3N1-E152-01ENZ0
XG2000 series User's Guide
Preface
You have purchased the XG2000 series, a compact, 20-port 10 Gigabit Ethernet layer 2 switch that achieves unsurpassed standards of high throughput and low-latency performance.
This guide describes the XG2000 series (XG2000 / XG2000C / XG2000CR) functions, installation procedures, configuration operations, and maintenance procedures and should be read and understood before you start using your XG2000 series.
March, 2008
Linux is a registered trademark or trademark of Linus Torvalds in the United States and/or other countries.
All Rights Reserved, Copyright © PFU LIMITED 2007-2008
2/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
About this Manual
This section describes target readers, contents, notations, etc. of this guide.
Target Readers and Required Knowledge
This guide was written for administrators, who are in charge of network construction, maintenance, and management.
To use this guide, the following knowledge is required.
Basic knowledge of networks, the Internet, and intranets
Basic knowledge of system security
This guide omits explanations of network protocol terms.
Contents
This guide to the XG2000 series is composed of the following chapters.
Chapter 1. Features and Functions
Describes the features and functions.
Chapter 2. Using the CLI
Describes operating environment of CLI and how to operate CLI.
Chapter 3. Installation
Describes the necessary installation procedures.
Chapter 4. Functions and Procedures for Setting Functions
Describes how to use the console screen.
Chapter 5. Command References
Describes how to use the commands.
Chapter 6. Managing the Device
Describes the management of the device.
Chapter 7. Troubleshooting
Describes how to solve problems in the device.
Appendix A. Event Logs
Describes the contents of messages reported by the device and actions to be taken for each message.
Appendix B. SNMP Traps
Describes message format of SNMP traps.
Appendix C. List of MIBs
Describes the list of MIBs supported by the SNMP agent
Related Manuals
The following are XG2000 series related manuals. Use these manuals as necessary.
XG2000 Series Hardware Guide
Describes the hardware of the XG2000 series.
Symbols Used in This Guide
The symbols used in this guide have the following meanings. indicates useful information related to using the XG2000 series. indicates precautions to take when using the XG2000 series. indicates supplementary information. indicates related matters such as operation procedures, etc.
3/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Contents
4/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
6/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
7/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
8/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Chapter 1 Features and Functions
This chapter describes the features and functions of the device.
9/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
1.1 Features
The XG2000 series is a compact, 20-port 10 Gigabit Ethernet Layer 2 switch, which provides the world's highest level throughput and least delay.
Special features of the XG2000 series are shown below:
Item Function Features
Basic Switch Functions
Scalability
Throughput 400Gbit/s
Latency 350ns (Exclude latency of XFPs)
Switching mode
MAC address learning table size
Either store-and-forward or cut-through is selectable.
16384 entries
MAC address learning
Jumbo frame support
Flow control
SVL (Shared VLAN Learning), IVL (Independent VLAN Learning), user selectable.
Up to 16KB (16128 bytes).
IEEE802.3x compliant pause frame control. Possible to specify flow control options for each port: send/receive or receive only.
Storm control
Port security
Ingress rate control
Port mirroring
Link pass through
Link aggregation
(Static and LACP)
Detects the broadcast storm status to prevent the traffic from overflowing the network and avoid degrading overall system performance.
Possible to restrict port access based on a source MAC address.
Supports by-port ingress rate control.
Possible to monitor the incoming/outgoing traffic by port mirroring.
Possible to synchronize the link state of a monitored port with the link state of a single or multiple ports.
Possible to increase bandwidth and redundancy. (Up to 10 ports for each link).
Also supports IEE802.3ad LACP.
VLAN support
Uplink Filter
IEEE802.1w RSTP
Filtering multicast, broadcast and unlearned unicast frames from leaf nodes to uplink. Possible to configure fat tree using several XG series.
Possible to make a redundant and loop-free network using Rapid
Spanning Tree Protocol (upward compatible with Spanning Tree
Protocol).
Max. 128 groups. IEEE802.1Q VLAN
Filtering Ingress/egress filtering
Multiple VLAN Possible to create multiple tag-based VLAN, with user VLAN tag identifier.
Multi-cast support
Network Management
Operation management
DiffServ
IGMP snooping
Traffic statistics
SNMP agent
Console by serial/management LAN
CLI
DSCP (DiffServ Code Point) of IPv4/IPv6.
Prevents unnecessary forwarding of multicast traffic to ports to reduce unnecessary multicast traffic.
Possible to analyze traffic and errors, using traffic statistics.
Can be used in conjunction with an SNMP manager, supporting
MIBs, including Standard MIB, Bridge MIB, and RMON MIB.
The security of the device is maintained from the serial interface or dedicated management LAN interface that is independent from the
10 Gigabit ports.
Allows the user to provide environment settings and operation management using command line interface (CLI).
10/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Chapter 2 Using the CLI
This chapter describes how to use the command line interface (CLI) to operate the device.
11/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
2.1 Overview of the CLI
This section describes how to use the command line interface (CLI) for the XG Series.
2.1.1 Operating Environment for the CLI
There are two ways to access the device to run commands. Up to 5 terminal sessions can access the device concurrently.
Serial connection
Connect to the serial port of the device using RS232C cable.
The available terminal emulation type is VT100.
When initially connecting a terminal to the device, configure the serial port on the client side as shown below.
Item Setting value
Baud rate 9600 bps (can be changed)
Character size 8 bit
Parity None
Stop bits 1 bit
Flow control None
Emulation VT100
Character set
Line feed code
ASCII
Transmission: CR (carriage return) only
Reception: LF is added
The baud rate can be changed to one of 9600, 19200, 38400 and 57600 (bps) using the "baud-rate" command.
Remote connection via management LAN port
Connect a terminal or host computer using a telnet or ssh client to the management LAN port of the device TCP port of 23(telnet) or 22(ssh) is used for the default telnet or ssh connection
The following tables list the factory defaults.
Management LAN Interface initial settings
Item
IP address
Subnet mask
192.168.0.2
255.255.255.0
Setting value
Telnet server initial settings
Item Setting value
Use telnet Disable (can be changed)
Port number 23 (TCP)
Emulation VT100/VT200/xterm
BackSpace key
Character set
Delete
ASCII
SSH server initial settings
Item Setting value
Use ssh
Port number
Disable (can be changed)
22 (TCP)
Emulation VT100/VT200/xterm
BackSpace key Delete
Character set
SSH Protocol
ASCII
Version 2 (not support version 1)
To use the remote connection via the management LAN port, use the "management-lan ip" command to configure the management LAN port for the device and use the "telnet-server" or “ssh-server” command to enable the telnet or ssh service.
A VT100, VT200, or xterm can be used as a terminal.
12/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
2.1.2 Command Modes and Mode Switching
The following table shows a hierarchy of command modes and mode switching.
Command Modes and Prompt Text
(host name for the device: xg)
Outline
Operator class
Operator EXEC mode
Prompt: xg>
Administrator class
Administrator EXEC mode
Prompt: xg#
Global configuration mode
Prompt: xg(config)#
Interface edit mode
Prompt: xg(config-if)#
xg(config-agg)# or
xg(config-vlan)#
Terminal edit mode
Prompt: xg(config-line)#
The initial-level operating mode entered upon logging into the system.
Allows access to commands that have no effect on the switch operations.
With the device, this mode is mainly used to view its status.
The prompt changes to "xg>".
To enter this level, use the "enable" command in the operator class or type the administrator's authentication password.
Allows users to perform operations that are related to the system management of the device, such as date/time setting and firmware update, in addition to those operations that are performed in the operator EXEC mode.
The prompt changes to "xg#".
To switch to the global configuration mode, enter the "configure terminal" command in the administrator EXEC mode.
This mode allows the user to define the environment settings for the device that are to be saved in a configuration file.
The prompt changes to "xg(config)#".
To enter the interface edit mode, enter the "interface" command in the global configuration mode.
This mode allows the user to configure each port or VLAN of the switch.
The interface edit mode is represented by prompt "xg(config-if)#", while the edit mode for a port that is created with link aggregation function is represented by prompt "xg(config-agg)#". Also, The edit mode for VLAN is represented by prompt “xg(config-vlan)#”.
To enter the serial terminal edit mode, enter the "line console" command in the global configuration mode.
The prompt changes to "xg(config-line)#".
Baud rate of the serial terminal and screen display size can be set.
13/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Entering a specific command allows switching from one mode to another. Entering the "exit" command returns program control to the previous mode.
Entering "end" command or pressing [Ctrl] and [Z], or [C] simultaneously in the global configuration, interface edit or terminal edit mode transfers program control to the administrator EXEC mode.
An example is given below.
Login: admin password: ******** xg> enable xg# configure terminal xg(config)# interface port 1 xg(config-if)# exit xg(config)# exit xg# copy running-config startup-config xg# exit
Switch to operator EXEC mode by performing a login operation.
By default, the login username is "admin" and password "password".
Use the "enable" command to switch to administrator EXEC mode.
Use the "configure terminal" command to switch to global configuration mode.
Use the "interface" command to switch to interface edit mode.
Use the "exit" command to return to global configuration mode.
Use the "exit" command to return to administrator EXEC mode.
Copy the current configuration file in memory to the startup-config in the nonvolatile memory.
User is logged out and session is disconnected.
Multiple users can use the operator and administrator EXEC modes concurrently. (Up to 5 terminals)
Only one terminal can switch to global configuration, interface edit or terminal edit modes at a time. It is not possible for multiple terminals to simultaneously switch to global configuration mode.
Pressing [Ctrl] and [C] simultaneously in the global configuration, interface edit or terminal edit mode transfers program control to the administrator EXEC mode when “- -more- -“ is displayed in the last line in the console screen.
(“- -more- -“ is displayed when display command, such as “show”, is executed and information exceed the console screen)
14/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
2.1.3 startup-config and running-config
The configuration information is saved to startup-config and running-config files.
This section describes the functions of the startup-config and running-config files. startup-config
Startup-config is the configuration file that stores the environment settings that are enabled upon device startup. The startup-config is saved in non-volatile memory and read the next time the device is reset or power cycled. running-config
Running-config is a file stored in volatile memory that represents the operating environment of the current running system. The information stored in the running-config file will be lost when the system is restarted.
To assure the system configuration that is active in the current running-config file is enabled the next time the system is started, use the "copy" command to save it to the startup-config file. xg# copy running-config startup-config
The contents of the startup-config and running-config match immediately after the device is started.
How to upload and save the startup-config and running-config files
This procedure can only be run from a host computer running a TFTP server and connected via a telnet or ssh session. To upload the configuration information to the TFTP server, run the "show" command. xg# show running-config | tftp HOST REMOTE-FILE or xg# show startup-config | tftp HOST REMOTE-FILE
How to download startup-config
To download the configuration information that was uploaded to the TFTP server as startup-config, run the "copy" command. xg# copy tftp HOST REMOTE-FILE startup-config
To enable the settings downloaded to the startup-config file, restart the device using the
"reset" command.
Be sure to upload the contents of the startup-config file to a TFTP server because the contents could be lost if the startup-config file is accidentally overwritten.
Refer to "
Uploading/Downloading a Configuration File " for details on uploading and downloading
configurations.
15/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
2.2 Using the CLI
2.2.1 How to Enter Commands
Command Entry Format
Separate each command, subcommand and argument with a single space.
<command> <subcommand> <argument 1> <argument 2> ... (" " indicates a space.) xg(config)# management-interface ip 192.168.1.10/24 default-gw 192.168.1.150 xg(config)# management-interface dns-server 192.168.1.150
Characters that can be entered:
− Any letter (A-Z, a-z) and digit (0-9)
− Space (ASCII code: 0x20)
− Symbols: !, ". #, $, %, `, ', (, ), _, -, ~, ^, ¥, {, }, :, +, ,, ., @, =, [, ], &, *, ;, /, ?, |, >
Command and option separators are recognized as one or more space characters (ASCII code:
0x20). Enclose a parameter in quotes if it contains a blank space.
The commands are not case-sensitive. Note that some entries (password, etc.) are case-sensitive.
2.2.2 Context-Sensitive Help
Entering a question mark "?" at the command prompt displays a list of commands available for each command mode. A list of command's associated with the keywords and parameters will be displayed.
A list of commands that are available in the current mode
Entering a question mark "?" at the system prompt displays a list of commands and brief descriptions available for the current command mode. xg # ?
Exec commands:
boot-system Change firmware to boot
clear Reset functions
configure Enter configuration mode
copy Copy from one file to another
date Manage the system date and time
delete Delete files on current system
dir List files on current system
:
(The rest is omitted.) xg# _
Word help
Entering a question mark "?" in the middle of a command name, will list the possible command options required to complete the command. The prompt will show the letters previously typed.
Enter the rest of the letters to complete the command entry. xg # co?
Exec commands:
configure Enter configuration mode
copy Copy from one file to another xg# co_
The CLI lists all possible commands that begin with "co".
A list of options that are available in the current entry position
Entering a question mark "?" followed by a space after typing a command name, will cause the CLI to list the possible commands or keywords that may be entered at the current option position. For option 2 and 3 positions, the CLI also lists options that can be entered at these positions. The prompt will show the letters previously typed.
Enter the rest of the letters to complete the command entry. xg# configure ? terminal Configure from the terminal xg# configure _
CLI lists possible options that follow the "configure" command.
The <cr> symbol may appear in the list to indicate that the command can be executed without entering any subsequent options. Parameters enclosed in square brackets can be omitted and, therefore, the <cr> symbol does not appear.
16/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
2.2.3 Command Completion
Entering part of a command or option and pressing the [Tab] key, causes the CLI to display the remaining command or option characters. xg# con<TAB>
↓ xg# configure _
For example, the only command that begins with "con" is "configure", so the CLI completes the command name as "configure".
Pressing the [Tab] key, causes the CLI to list all possible commands or option names. xg# co<TAB> configure copy xg# co_
Since there are two commands that begin with "co" - "configure" and "copy" - the CLI lists both commands.
2.2.4 Command Abbreviation
Commands and options can be abbreviated to the minimum number of characters as long as command or option names are unique and forward-match the entered letters. xg# con t
For example, the "configure" command may be abbreviated to "con" because "configure" is the only command that begins with
"con", and "terminal" may be abbreviated to "t" because "terminal" is the only command that begins with "t".
2.2.5 Command-Line Error Messages
The table below shows error messages that appear when a command is incorrectly entered. The "configure terminal" command is used as an example below:
Error Message Explanation
xg# co t
% Ambiguous command: "co t" xg# configure
% Incomplete command. xg# configure aerminal
^
% Invalid input detected at '^' marker xg# coc?
% Unrecognized command
Insufficient characters were entered for the CLI to recognize the command.
Re-enter the correct command string.
All of the options or values required by this command were not entered.
Enter all necessary options and values.
The command incorrectly entered. A caret symbol (^) indicates the incorrect entry.
Correct the entries and execute the command again.
Part of the command was incorrectly entered.
Re-enter the correct command string.
2.2.6 Scrolling Down or Up a Line or a Page
When the information displayed by a command contains more lines than the console screen will display, a "--More--" prompt is displayed at the bottom of the screen and the CLI waits for a user entry. xg# show running-config
! interface port 1
:
:
(The rest is omitted.)
:
--More--
Scrolling Up a Line
To scroll up one line, press the [Enter] key.
Scrolling Up a Page
To scroll up one page, press the [Space] bar.
Finishing Displaying
To finish displaying, press the [q] or [Q] key.
The following table shows the combinations of shortcut keys, function keys and the [Ctrl] key used to edit commands.
17/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Combinations of keys
"
↑" or [Ctrl] + [P]
"
↓" or [Ctrl] + [N]
"
←" or [Ctrl] + [B]
"
→" or [Ctrl] + [F]
[Home] or [Ctrl] + [A]
[End] or [Ctrl] + [E]
[Esc] + [B]
[Esc] + [F]
[Backspace]
[Delete] or [Ctrl] + [D]
[Ctrl] + [W]
[Ctrl] + [U]
[Ctrl] + [K]
[Ctrl] + [Y]
[Ctrl] + [L]
[Ctrl] + [C]
[Enter], [Ctrl] + [J], or [Ctrl] + [M]
[Ctrl] + [T]
Description
Recalls the previous command.
Recalls the next command.
Moves the cursor back one character.
Moves the cursor forward one character.
Moves the cursor to the first character in line.
Moves the cursor to the last character in line.
Moves the cursor back one word (to the beginning of a parameter).
Moves the cursor forward one word (to the beginning of a parameter).
Erases the character to the left of the cursor and moves the cursor back one character.
Deletes the character to the right of the cursor.
Records the character to the left of the cursor before deleting.
Records the command line before deleting.
Records all characters to the left of the cursor before deleting.
Pastes a string recorded by [Ctrl]+[W], [U] or [K].
Erases the current screen.
Runs command result and aborts output.
Completes a command entry.
Transposes the character located at the cursor with the character to the left of the cursor.
If any of the above key combinations or command completion displays using the [Tab] key do not work correctly, the correct VT100, VT200 or xterm terminal emulation type may not be selected.
2.2.7 Command History
Command history is a function that records command lines previously entered so they can be reused.
It is useful for repeatedly entering the same command line or for entering a similar command.
To display the previous command line in the history:
Press the up arrow key or [Ctrl]+[P] to recall the previous command in the history to the prompt.
Repeat the key sequence to recall successively older commands.
To display a more recent command line:
Press the down arrow key or [Ctrl]+[N] to bring up the next line from the command history to the prompt.
Repeat the key sequence to bring up successively more recent commands.
To list the command history:
Use the "show history" command to view the list of commands saved in the history:
For each login up to 100 lines of command history can be registered.
2.2.8 Aborting Command
An executing command can be aborted by pressing [Ctrl]+[C]. Note that this key sequence may not be effective for some commands.
2.2.9 No Form of Commands
Almost every configuration command has a no form. In general, the no form is used to cancel the settings of a configuration command or restore default values.
Type "no" before entering a command name.
For details on using the no form, refer to the "
18/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
2.2.10 Filtering show Command Output
This function allows filtering the show command output so lines that only satisfy specific conditions (filter for strings) are displayed. This function is useful in excluding unnecessary information from a large amount of output.
To use it, a "show" command must be followed by a keyword (pipe (|), begin, include or exclude) and a regular expression
(filtering condition).
Syntax show | {begin | include | exclude} regular-expression
Keyword for filtering output Meaning begin exclude include
Begins output starting at the first line that contains matches to given regular expression parameters.
Does not display output lines that contain matches to given regular expression parameters.
Displays output lines that contain matches to given regular expression parameters. xg# show history | begin 2
...skipping
2 configure terminal
3 show running-config
4 show history
5 show history | begin 2 xg# show history | exclude 2
1 enable
3 show running-config
4 show history xg# show history | include 2
2 configure terminal
5 show history | begin 2
Regular expressions are case sensitive.
For example, if "| exclude strings" is entered, lines that include "String" are output, but those that include "strings" are not.
2.2.11 Redirecting show Command Output
Redirect the output of "show" commands to a file in volatile memory using ">" (pipe) or "|” (redirect).
Syntax (To redirect the output of a show command to a file in volatile memory:) show > FILE-NAME show | FILE-NAME
FILE-NAME
Specifies the file name in volatile memory that the output of the command is piped or redirected.
"| tftp" redirects the output of the show command to a file on a TFTP server.
Syntax (Redirect the output of a show command to a file on a TFTP server:) show | tftp HOST REMOTE-FILE
HOST
Specifies the host name or IP address of the TFTP server.
REMOTE-FILE
Specifies the file name in the TFTP server that the output of the command is redirected.
In the following example, the current startup-config is redirected as filename "startup_09302005", the running-config file is redirected as filename "running_09302005", and system information is redirected as filename "system_09302005".
The results of the redirection are confirmed with the "ls" command.
Then, using the "tftp" command, each of these files are moved to the TFTP server. xg# show startup-config > startup_09302005 xg# show running-config > running_09302005 xg# show system information > system_09302005 xg# ls
(ls command output)
Update-time File-size File-name
- 2005/09/30 11:57:27 872 system_09302005
- 2005/09/30 11:54:01 2,310 startup_09302005
- 2005/09/30 11:55:58 2,437 running_09302005 xg# tftp put remote-host1 startup_09302005 restore_startup_09302005 xg# tftp put remote-host1 running_09302005 restore_running_09302005 xg# tftp put remote-host1 system_09302005 restore_system_09302005
In the following example, show command output is redirected to TFTP server "remote-host1" using "| tftp". xg# show startup-config | tftp remote-host1 restore_ startup_09302005 xg# show running-config | tftp remote-host1 restore_running_09302005 xg# show system information | tftp remote-host1 restore_system_09302005
19/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
2.2.12 Using the monitor Command
The monitor command provides additional key commands to perform screen navigation.
The following table shows the keys used to perform screen-related operations.
Displayed item Meaning
ESC:exit
F:refresh
U:page up
Press the [Esc] key to close the monitor screen.
Press the [F] or [f] key to refresh the screen.
Press the [U] or [u] key to scroll up to the previous page.
If the current page is the first page of the display nothing occurs.
D:page down
L:page left
R:page right
Press the [D] or [d] key to scroll down to the next page.
If the current page is the last page of the display, nothing occurs.
Press the [L] or [l] key to scroll the screen to the left.
If there are no additional columns of data to the left to display, nothing occurs.
Press the [R] or [r] key to scroll the screen to the right.
If there are no additional columns of data to the right of the display, nothing occurs.
20/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Chapter 3 Installation
This chapter describes the installation procedures for the device.
Refer to "
Using the CLI " for details on using the CLI.
Refer to "
Command Reference " for details on commands.
21/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
3.1 Workflow for Initial Setup of the Device
This section describes the procedures to setup the device.
1. Prepare
Prepare a terminal for the initial configuration.
2.
Setting Up the Serial Interface
Connect the device and terminal with an RS232C cable. The initial baud rate setting is 9,600 bps.
3. Turn on the device to start the system.
Turn on the terminal and the device to start the system.
4.
Configure Management LAN Interface
The initial setting of the management LAN interface is disabled.
To use the following functions, set up the management LAN interface:
− Telnet connection
− SSH connection
− SNMP manager connection
− System log transmission
− Time synchronization using an NTP server
− Configuration file upload/download
− Firmware update
− Collection of maintenance information
5.
Telnet Connection via Management LAN Interface (Optional)
The initial setting of the Telnet connection via the management LAN interface is disabled.
(IP address: 192.168.0.2, subnet address: 255.255.255.0)
6. SSH Connection via Management LAN Interface (Optional)
The initial setting of the SSH connection via the management LAN interface is disabled.
7.
Initially, the SNMP agent configuration is not set.
Set the SNMP configuration as needed.
8. This is the end of the preparation procedure
Proceed with configuring the switch.
3.1.1 Setting Up the Serial Interface
Connect the device and terminal with an RS232C cable. The initial setting of baud rate setting is 9,600 bps.
Refer to "
Operating Environment for the CLI " for details on settings.
For serial interfaces, only the baud rate can be changed. To change the serial interface settings, carry out the following procedure.
Command
xg login: admin
Password: ******** xg> enable xg# configure terminal
Task
Log in to the device from the serial terminal. The default user name is "admin". The default password is "password".
Switch to administrator EXEC mode.
Switch to global configuration mode. xg(config)# line console xg(config-line)# baud-rate {9600 | 19200 |
38400 | 57600}
Switch to serial terminal edit mode.
Change serial baud rate.
The baud rate is changed after the logout. xg(config-line)# exit
Exit to global configuration mode. xg(config)# terminal timeout console MINUTES
(Optional)
If the terminal is idle after the timeout period (in minutes) expires the serial connection is terminated. The default is xg(config)# exit
10 minutes.
Exit to administrator EXEC mode.
22/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
3.1.2 Configure Management LAN Interface
The management LAN interface is initially enabled.
(IP address: 192.168.0.2, subnet address: 255.255.255.0)
To use the following functions, configure the management LAN interface.
− Telnet connection (enabled by default)
− SSH connection (disabled by default)
− SNMP manager connection
− System log transmission
− Time synchronization using an NTP server
− Configuration file upload/download
− Firmware update
− Collection of maintenance information
To configure the management LAN interface, carry out the following procedure.
Command
xg login: admin
Password: ******** xg> enable
Task
Log in to the device from the serial terminal. The default user name is "admin". The default password is "password."
Switch to administrator EXEC mode. xg# configure terminal xg(config)# management-lan ip A.B.C.D/M
[ default-gw A.B.C.D]
Switch to global configuration mode.
Change the IP address and subnet, and set the default gateway of the management LAN interface. xg(config)# management-lan dns-server A.B.C.D
(Optional)
Set up DNS servers. Up to 4 DNS servers can be set up.
Priority is assigned to DNS servers in the order they are defined. To change their order, delete them using the no command before doing so. xg(config)# management-lan domain DOMAIN-NAME
(Optional)
Set the name of the network domain. xg(config)# remote-host A.B.C.D HOST-NAME xg(config)# exit
(Optional)
Associate a remote host name with an IP address.
This allows referencing a remote IP address with a host name without relying on a DNS server.
Exit to administrator EXEC mode.
3.1.3 Telnet Connection via the Management LAN Interface (Optional)
The "Telnet server function" via the management LAN interface is initially disabled.
To change the monitoring time for the telnet connection, carry out the following procedure in the administrator EXEC mode.
Command Task
xg# configure terminal xg(config)# telnet-server xg(config)# terminal timeout vty <0-60> xg(config)# exit
Switch to global configuration mode.
Enable Telnet connection,
(Optional)
If the Telnet session timeout period (in minutes) expires the telnet connection is terminated.
Exit to administrator EXEC mode.
23/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
3.1.4 SSH Connection via the Management LAN Interface (Optional)
This device supports the “SSH server function”. This function is remote connection like “Telnet server function”.
After executing “ssh-server” command, the “SSH-server” is enabled and authentication key is generated (It takes some time to generate authentication key).
The following shows the “SSH-server function” supported by this device.
Function
Protocol Version
Method of authentication
Authentication key
Support
v2
Password
RSA(2048bits, fixed), DSA(1024bits, fixed)
Automatically generated, CLI Method to generate authentication key
Method of coding
Terminal sessions
Message authentication code aes128-cbc,3des-cbc,blowfish-cbc,cast128-cbc,arcfour128,ar cfour256,arcfour,aes192-cbc,aes256-cbc,aes128-ctr,aes192-c tr,aes256-ctr
Maximum 4
(both Serial and Telnet connections) hmac-md5,hmac-sha1,[email protected],hmac-ripemd
160,hmac-sha1-96,hmac-md5-96
The "SSH server function" via the management LAN interface is initially disabled.
To change the monitoring time for the ssh connection, carry out the following procedure in the administrator EXEC mode.
Command Task
sw# configure terminal sw(config)# ssh-server sw(config)# terminal timeout vty <0-60> sw(config)# exit
Switch to global configuration mode.
Enable SSH connection
(Optional)
If the SSH session timeout period (in minutes) expires the ssh connection is terminated.
Exit to administrator EXEC mode.
The “SSH-server function” supported by this device uses Open SSH free software that is published based on BSD licence.
Please refer to the following URL for more details. http://www.openssh.com/
24/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
3.1.5 SNMP Configuration (Optional)
To operate in conjunction with an SNMP manager, the SNMP agent must be configured.
To configure the SNMP agent, carry out the following procedures in the administrator EXEC mode.
Command
xg# configure terminal
Task
Switch to global configuration mode. xg(config)# hostname HOST-NAME xg(config)# snmp-server location
SYSTEM-LOCATION
Set the switch name (HOST-NAME), switch's location
(SYSTEM-LOCATION), and contact
(SYSTEM-CONTACT). xg(config)# snmp-server contact
SYSTEM-CONTACT xg(config)# snmp-server access host
{A.B.C.D|HOSTNAME} community COMMUNITY-NAME xg(config)# snmp-server trap host
{A.B.C.D|HOSTNAME} community COMMUNITY-NAME
[protocol {v1|v2c}] xg(config)# exit
Set the IP address (host name) of the SNMP manager and the community name.
Set the IP address (host name) of the host that is notified of SNMP traps and community name, if the SNMP trap notification is enabled.
Exit to administrator EXEC mode.
25/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Chapter 4 Switch Functions and their
Configuration
This chapter describes the functions of the device and how to configure them.
Refer to "
Operating Environment for the CLI " for details on using the CLI.
Refer to "
Command Reference " for details on commands.
26/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.1 Basic Switch Functions
This section describes the basic switch functions.
4.1.1 Switching Mode
The device provides the following two switching modes.
Store-and-forward switching mode
After the device finishes receiving a frame, it checks the FCS (Frame Check Sequence) and performs a validity check (on packet size, etc.) before forwarding the frame. If the switch receives a frame with an error frame, it discards it.
Cut-through switching mode
The device transmits the frame to the destination as soon as the first 64 bytes of the frame are received with no errors. Since the device starts transmitting the frame before it receives the entire frame, this mode allows forwarding at low latency.
To change the switching modes, carry out the following procedures in the administrator EXEC mode.
Command
xg# configure terminal xg(config)# bridge forward-mode
{cut-through | store-and-forward }
Task
Switch to global configuration mode.
Select the cut-through (or store-and-forward) for the switching mode. xg(config)# no bridge forward-mode xg(config)# exit
Exit to administrator EXEC mode.
4.1.2 MAC Address Table Management
The MAC address table is a database used for managing the association between address information and destination ports.
The device can learn up to 16384 entries of MAC addresses.
MAC address table management
The device has two methods for MAC address table management.
− SVL(Shared VLAN Learning)
The device learns MAC addresses common to all VLANs. Different VLANs with identical
MAC addresses are treated as identical entries.
− IVL(Independent VLAN Learning)
The device learns MAC addresses separately for each VLAN. Identical MAC addresses with different VLANs are treated as separate entries.
To change the MAC address table management modes, carry out the following procedures in the management EXEC mode.
Command
xg# configure terminal xg(config)# bridge learn-mode { ivl | svl } xg(config)# no bridge learn-mode
Task
Switch to the global configuration mode.
Select IVL or SVL for the MAC address table management mode. xg(config)# exit xg# copy running-config startup-config xg# reset
Exit to administrator EXEC mode.
Save the current settings of the device to nonvolatile memory.
If the MAC address table management mode is changed, the new setting becomes enabled after the device is restarted. xg(config)# interface port 1 2 3 xg(config-if)# suppress-address-learning
Dynamic MAC address learning
The device dynamically learns MAC addresses from received frames. If MAC addresses are not refreshed before the aging time expires, they will be removed from the MAC address table.
To disable the dynamic learning, carry out the following procedures in the administrator
EXEC mode.
Command
xg# configure terminal xg(config)# interface port range 1 3
Task
Switch to global configuration mode.
Switch to the interface edit mode to specify the port(s) to be configured.
In this example, the global interface configuration mode is selected for ports 1 through 3.
Enable (or disable) the dynamic MAC address learning. xg(config-if)# no suppress-address-learning xg(config-if)# exit xg(config)# exit
Exit to global configuration mode.
Exit to administrator EXEC mode.
27/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Static unicast address
By registering a unicast MAC address with the MAC address table, unicast frames are forwarded to a specified port. Static unicast addresses are not subject to MAC address removal controlled by the aging function.
To register, change or delete a static unicast address, carry out the following procedures in the administrator EXEC mode.
Command
xg# configure terminal xg(config)# bridge mac-address-table
static MAC [vlan <1-4094>]
Task
Switch to global configuration mode.
Register a static unicast address and destination port with the
MAC address table (or remove them from it).
{[port <1-20>] | [agg-port <1-10>]} xg(config)# no bridge mac-address-table
static MAC [vlan <1-4094>] xg(config)# exit
Exit to administrator EXEC mode.
Static multicast address
By registering a multicast MAC address with the MAC address table, a specific multicast frame will be forwarded to a designated port.
To register, change or delete a multicast address, carry out the following procedures in the administrator EXEC mode.
Command
xg# configure terminal xg(config)# bridge mac-address-table
static MAC [vlan <1-4094>]
[port <1-20> [<1-20> ]]
Task
Switch to global configuration mode.
Register (or remove) a static multicast address table and destination port.
For a multicast MAC address, multiple ports can be specified.
[agg-port <1-10> [<1-10> ]] xg(config)# no bridge mac-address-table
static MAC [vlan <1-4094>] xg(config)# exit
Exit to administrator EXEC mode.
4.1.3 Jumbo Frame Support
The device can transmit jumbo frames of up to 16KB (16128 bytes).
To configure jumbo frame support, carry out the following procedure in the administrator EXEC mode.
Command Task
xg# configure terminal xg(config)# bridge jumbo-frame
Switch to global configuration mode.
Enable (or disable) jumbo frame support.
[{9216 | 12288 | 15360 | 16128}] xg(config)# no bridge jumbo-frame xg(config)# exit
Exit to administrator EXEC mode.
4.1.4 Flow Control
Flow control is a function that prevents frame loss when the receive buffer in the switch overflows due to temporary traffic overload by using a PAUSE frame.
When the device receives a PAUSE frame, it temporarily stops sending frames at the receive port. If the receive buffer overflows, it is possible to restrict frame transmission from the connected device by sending a PAUSE frame.
For each port, it is possible to select whether or not to send a PAUSE frame. Select the mode depending on whether the destination responds to a PAUSE frame or not.
To change the flow control mode, carry out the following procedures in the administrator EXEC mode.
Command Task
xg# configure terminal xg(config)# interface port 1 2 3 xg(config)# interface port range 1 3 xg(config-if)# flowcontrol
Switch to global configuration mode.
Switch to the interface edit mode to specify the port(s) to be configured for flow control.
In this example, the global interface configuration mode is selected for ports 1 through 3.
Set the flow control mode.
{ only-receive | send-receive } xg(config-if)# exit xg(config)# exit
Exit to global configuration mode.
Exit to administrator EXEC mode.
28/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.1.5 Storm Control
The device discards broadcast frames when the number of received broadcast frames are over a given threshold to prevent unnecessary waste of bandwidth due to retained broadcast frames on the network. This function is called "Storm Control".
For each port, it is possible to configure storm control.
When broadcast frames are discarded by storm control, error logs are output, and storm control logging is disabled. To re-enabled logging, these violations must be cleared with "clear violation".
To configure storm control, carry out the following procedures in the administrator EXEC mode.
Command Task
xg# configure terminal xg(config)# interface port 1 2 3 xg(config)# interface port range 1 3 xg(config-if)# storm-control xg(config-if)# exit xg(config)# exit
Switch to global configuration mode.
Switch to the interface edit mode to specify the port(s) to be configured for storm control.
In this example, the global interface configuration mode is selected for ports 1 though 3.
Enable storm control.
Exit to global configuration mode.
Exit to administrator EXEC mode.
4.1.6 Port Security
Port security blocks connections attempted by unregistered hosts. When a host MAC address is registered, the device receives only those frames that use registered source addresses.
For each port, it is possible to configure port security. To register a MAC address for a host, use the "bridge mac-address-table static" command. The port that the host is connected must be registered as a member port. In Independent VLAN Learning mode, this must be done for all VLANs that permit transmission.
Either of the following two modes can be specified for a security-violating (unregistered) frame the device receives.
− Restrict mode
Filters violating frames only, forwarding permitted frames.
− Shutdown mode
Filters all frames upon reception of a violating frame, and the port goes link down.
Once a security violation is detected, an error log is recorded. No further detection of a violating frame will cause an error log to be recorded until security violations are reset by "clear violation".
To configure port security, carry out the following procedures in the administrator EXEC mode.
Command Task
xg# configure terminal xg(config)# interface port 1 2 3 xg(config)# interface port range 1 3 xg(config-if)# port-security violation
{restrict | shutdown} xg(config-if)# clear violation xg(config-if)# exit xg(config)# exit
Switch to global configuration mode.
Switch to the interface edit mode to specify the port(s) to be configured for port security.
In this example, the global interface configuration mode is selected for ports 1 though 3.
Enable Port Security.
Clear security violations.
Exit to global configuration mode.
Exit to administrator EXEC mode.
4.1.7 Ingress Rate Control
It is possible to set an ingress rate-limiting value for each port in approximately 40Mbps increments.
To set an ingress rate-limiting value, carry out the following procedures in the administrator EXEC mode.
Command Task
xg# configure terminal xg(config)# interface port 1 2 3 xg(config)# interface port range 1 3
Switch to global configuration mode.
Switch to the interface edit mode to specify the port(s) to be configured for ingress rate control.
In this example, the global interface configuration mode is selected for ports 1 though 3. xg(config-if)# ingress-bandwidth <40-10000>
Specify an ingress rate limiting value. xg(config-if)# exit xg(config)# exit
Exit to global configuration mode.
Exit to administrator EXEC mode.
The ingress rate is measured at 100us time intervals. Should burst transfers take place at intervals of 100us or over, the ingress rate the device actually allows may be less than the specified value.
29/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.2 Port Mirroring
It is possible to monitor the traffic by mirroring the frames sent or received by a port to another port. Multiple ports may not be mirrored to one port. However, multiple ports may be mirrored.
To configure port mirroring, carry out the following procedure in the administrator EXEC mode.
Command
xg# configure terminal xg(config)# mirror monitored-port <1-20>
[rx-mirroring-port <1-20>]
Task
Switch to global configuration mode.
Configure the port to be monitored and its mirror port to be mirrored.
[tx-mirroring-port <1-20>] xg(config)# exit xg# show mirror
Exit to administrator EXEC mode.
View the status of port mirroring.
30/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.3 Link Pass Through
Link pass through is a function that monitors the status of a specified port link and notifies the device connected to the port via link status notification of the link status of a monitored port by synchronizing the monitored port with the link status on the port.
This function allows the device to notify the port, after link status notification, of a link fault if detected at the monitored port.
Link pass through communicates the link fault status to the other port by sending a remote fault (RF) signal, as prescribed in
IEEE802.3ae LFS (Link Fault Signaling). When the link status of the monitored port is restored to normal, the other port is also restored to normal, thereby restoring the network link.
To configure Link pass through, carry out the following procedure in the administrator EXEC mode.
Command Task
xg# configure terminal xg(config)# link-pass-through { monitored-port
<1-20> | monitored-agg-port <1-10>}
Switch to global configuration mode.
Set the relationship between the ports to be monitored and ports link status notification were sent.
[domino-port <1-20> [<1-20> ]]
[domino-agg-port <1-10> [<1-10> ]] xg(config)# exit
Exit to administrator EXEC mode.
31/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.4 Link Aggregation
Link aggregation is a function that combines multiple ports into a single logical link. A set of ports that comprise a logical link is called an aggregation group.
Link aggregation provides:
Increased bandwidth
By grouping multiple physical ports into a single logical link (an aggregation group), network traffic (data sent and received) will be balanced across the physical ports, thereby providing increased bandwidth.
Redundancy
Multiplexing ports allows uninterrupted network operations should one of the multiple links fail. Since the link status of the logical aggregation groups remains unchanged, there are no fluctuations in network traffic, the effect of a fault having been minimized.
Up to 10 ports can be used to create a single link aggregation group using link aggregation. Up to 10 aggregation groups can be created.
32/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.4.1 Configuring Link Aggregation
Either static or dynamic (also known as LACP) configuration can be selected for Link Aggregation.
Static configuration
Configures aggregation groups statically.
LACP
Configures link aggregation using Link Aggregation Control Protocol (LACP). The LACP is a switch-to-switch control protocol that enables dynamic configuration of aggregation groups and is standardized by the IEEE802.3ad. The LACP facilitates load balancing across the individual links aggregated between the devices connected.
Either "active" or "passive" LACP mode can be selected.
− active
The device starts LACP negotiation. Since the active mode allows the reception of LACP control frames, it is possible to direct the device in "active" mode.
− passive
The device responds to LACP control frames but does not start LACP negotiation.
To configure static link aggregation, carry out the following procedure in the administrator EXEC mode.
Command Task
xg# configure terminal
Switch to global configuration mode. xg(config)# link-aggregation agg-port <1-10>
protocol none port <1-20> <1-20> xg(config)# interface agg-port <1-10> xg(config-agg)# port-vlan-id vlan 2 xg(config-agg)# exit xg(config)# exit
Assign a number to the aggregation group to be created
(agg-port) and the port numbers assigned to the link aggregation.
Specify "none" for static configuration.
To change the setting of the aggregation group created, switch to the interface edit mode for the aggregation group and specify the "interface agg-port" requiring change.
The prompt changes to "config-agg".
(Optional)
Change the setting of the aggregation group as required. In this example, default VLAN ID is set to 2.
Exit to global configuration mode.
Exit to administrator EXEC mode.
To configure LACP link aggregation, carry out the following procedure in the administrator EXEC mode.
Command
xg# configure terminal
Task
Switch to global configuration mode. xg(config)# link-aggregation agg-port <1-10>
protocol lacp lacp-mode {active | passive }
port <1-20> <1-20> xg(config)# interface agg-port <1-10> xg(config-agg)# port-vlan-id vlan 2 xg(config-agg)# exit xg(config)# exit
Assign a number to the aggregation group to be created
(agg-port) and the port numbers assigned to the link aggregation.
Specify "lacp" for LACP link aggregation. Specify the desired negotiation operational mode in "lacp-mode".
To change the setting of the aggregation group created, switch to the interface edit mode for the aggregation group and specify the "interface agg-port" requiring change.
The prompt changes to "config-agg".
(Optional)
Change the settings of the aggregation group as required. In this example, default VLAN ID is set to 2.
Exit to global configuration mode.
Exit to administrator EXEC mode.
33/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.4.2 Frame Distribution Methods in Link Aggregation
How frames are distributed across physical ports that make up an aggregation group are determined by the contents of a frame (source and destination MAC addresses).
There are three ways to specify how frames are distributed:
Frame distribution based on destination MAC address (dst-mac)
The destination port is determined based on the destination MAC address of the frames.
Frame distribution based on source MAC address (src-mac)
The destination port is determined based on the source MAC address of the frames.
Frame distribution based on destination and source MAC addresses (dst-src-mac)
The destination port is determined based on the destination and source MAC addresses of the frames.
If there are too few MAC addresses to be distributed across an aggregation group, the distribution of frames across the destination ports tends to become biased. To reduce such bias, use a distribution method that uses more MAC addresses.
For example, if a server is connected to an aggregation group and a client is connected to a different port, the "src-mac" or "dst-src-mac" parameters are recommended.
To set a distribution method, carry out the following procedure in the administrator EXEC mode.
Command
xg# configure terminal
Task
Switch to global configuration mode. xg(config)# link-aggregation agg-port <1-10> protocol {none | lacp}
Specify a distribution method in the load-balance parameter of the "link-aggregation" command. load-balance dst-mac|src-mac|dst-src-mac} port <1-20> <1-20> xg(config)# exit
Exit to administrator EXEC mode.
4.4.3 The Number of Ports That Require Linkup
It is possible to specify the number of ports that enable a linkup state for an aggregation group. If the number of active ports that make up an aggregation group in a linkup state is less than the specified number of ports, the aggregation group changes to a linkdown state.
For static link aggregation
If the number of ports that make up an aggregation group in a linkup state no longer satisfies the specified number of ports, the aggregation group changes to a linkdown state.
For LACP link aggregation
If the number of ports that make up an established LACP aggregation group changes, the aggregation group reverts to a linkdown state.
To set the number of ports in the aggregation group, carry out the following procedure in the administrator EXEC mode.
Command Task
xg# configure terminal xg(config)# link-aggregation agg-port
<1-10>
protocol {none | lacp} minimum-port <1-20>
Switch to global configuration mode.
Specify the required number of ports in "minimum-port" parameter of the "link-aggregation" command.
The default value for "minimum-port" parameter is 1.
port <1-20> <1-20> xg(config)# exit
Exit to administrator EXEC mode.
34/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.4.4 Notes on Link Aggregation
The smallest port number in an aggregation group serves as the master port.
Port settings established after defining an aggregation group inherit the same settings as those of the master port, with some exceptions. The settings that are not inherited from the master port are.
"link-pass-through"
Settings for these ports are cleared.
The information registered in MAC address table
All addresses related to ports configured are cleared.
"spanning-tree port-path-cost"
Port-path-cost will be re-adjusted to match the new configuration.
When changing the port settings for aggregation groups that have already been created, the aggregation group changes to a linkdown state, and then to a linkup state if one of the following conditions are satisfied.
A master port was removed
A master port changed
The "protocol" or "lacp-mode" parameter changed
35/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.5 Uplink Filter
When an uplink domain is defined, the domain's uplink domain ports filter (drops) multicast, broadcast and unlearned (flooding) unicast frames from non-membership downlink ports. However it does not filter learned unicast frames that are forwarded based on the MAC address table.
The uplink filter is useful in configuring large networks with multiple paths, such as a fat tree network, by cascading multiple
XG-series switches.
To configure an uplink filter, specify an uplink domain whose membership consists of one or more downlink ports and one or more uplink ports. For example, in a fat tree network, an uplink domain is configured such that ports connected to switches are designated as uplink ports, and leaf nodes as downlink ports. The uplink domain will then block multicast, broadcast and flooding unicast frames to other uplink domains configured within the switch and only distribute traffic from the downlink to the uplink ports within that domain.
If an uplink filter is specified to have multiple uplink ports, link aggregation and redundancy are provisioned within that domain.
The uplink filter differs from link aggregation in that the uplink ports within the uplink domain can be connected to different switches or equipment to ensure redundancy within the various uplink ports.
36/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
When specifying multiple uplink ports within an uplink domain, frame distribution among the uplink ports is performed equally from port to port and not by type of frame. Frame distribution changes automatically when a fail-over or fail-back occurs, thereby providing uplink redundancy.
37/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
The following is an example of a fat tree configuration with network redundancy.
To configure an uplink filter, carry out the following procedures in the administrator EXEC mode.
Command
xg# configure terminal
Task
Switch to global configuration mode. xg(config)# uplink-domain 1 port 11 12 xg(config)# interface port 1 2 3
(interface port range 1 3)
Create an uplink domain that consists of port 11 and 12.
Switch to interface edit mode to assign downlink ports.
In this example, the global interface configuration mode is selected for ports 1 through 3. xg(config-if)# downlink allowed uplink-domain 1
Register each port as a downlink member of the uplink domain. xg(config-if)# exit xg(config)# exit xg# show uplink
Exit to global configuration mode.
Exit to administrator EXEC mode.
View the state of the uplink.
Multicast, broadcast, and unlearned unicast frames are filtered by the uplink filter. But both statically and dynamically learned unicast frames forwarded to a specified port are not filtered.
An uplink port is not allowed to be a member of a link aggregation group.
STP must be disabled on uplink ports.
The IGMP snooping and uplink filter features cannot be used at the same time.
38/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.6 Spanning Tree Protocol (STP)
The Spanning Tree Protocol (STP) is a function that prevents loops from occurring on a network. It is also possible to provide network redundancy by intentionally creating a loop.
STP exclusively uses only one active path between network devices, and shuts out other paths, to avoid network loops. An active path is selected by comparing path costs defined on each path. After the comparison, the lowest cost path will be selected. If the selected path becomes disabled, STP will activate the lowest cost path amongst the paths remaining.
The device supports IEEE802.1w RSTP (Rapid Spanning Tree Protocol). The RSTP is upward compatible with IEEE802.1D
STP (Spanning Tree Protocol) and serves as a STP if the destination device only supports STP.
39/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.6.1 Port Roles Based on Spanning Tree
RSTP assigns one of these port roles to individual ports:
Root port
Provides the best path (lowest cost) when the switch forwards packets to the root switch.
Designated port
Connects to the designated switch toward the leaves of the spanning tree. The port specified connecting to the designated port serves as a root port.
Alternate Port
The alternative port with the second lowest path cost. In the event that the root port goes to a linkdown state, the alternate port serves as the root port. It does not always send or receive frames while in the blocking state.
Backup Port
Provides an alternative path to that specified. In the event that the specified port goes into a linkdown state, the backup port serves as the new designated port. It does not always send or receive frames while it is in the blocking state.
Disabled Port
Disabled port, it does not send or receive any frames.
4.6.2 Spanning Tree Protocol Port States
The port states defined by the STP are:
Discard
The port is in a "discarding state. BPDUs are only received.
Learn
The port is in a "learning" state. A port in the learning state learns the destination MAC address of the received frames but does not participate in frame forwarding.
Forward
The port is ready to transmit data traffic.
The STP states "blocking" and "listening" have been merged into a unique RSTP "discarding" state. The correspondence between STP port states and RSTP port states are shown below.
Display STP(IEEE802.1D) RSTP(IEEE802.1w)
Format
Discard Blocking
Discard Listening
Learn Learning
Forward Forwarding
Discarding
Discarding
Learning
Forwarding
4.6.3 Configuring Spanning Tree
To configure the spanning tree protocol, carry out the following procedure in the administrator EXEC mode.
Command Task
xg# configure terminal xg(config)# spanning-tree xg(config)# spanning-tree priority <0-61440> xg(config)# spanning-tree hello-time <1-10> xg(config)# spanning-tree max-age <6-40> xg(config)# spanning-tree forward-time <4-30> xg(config)# interface port 1 2 3 xg(config)# interface port range 1 3 xg(config-if)# spanning-tree port-priority
<0-240> xg(config-if)# spanning-tree port-path-cost
<1-200000000>
Switch to global configuration mode.
Enable Spanning Tree Protocol.
Configure Spanning Tree Protocol parameters on the device.
Switch priority
Hello time
Maximum aging time (max-age)
Forward delay time (forward-time)
Switch to interface edit mode to configure spanning tree-related parameters for a given port.
In this example, the global interface configuration mode is selected for ports 1 through 3.
Configure the following parameters related to the spanning tree topology:
Port priority
Path cost xg(config-if)# spanning-tree portfast xg(config-if)# exit xg(config)# exit xg# show spanning-tree [ detail ]
(Optional)
If the port is configured as an edge port(*), this setting can reduce the time taken to transition into the forwarding state.
* It is available only when the port is directly connected to an end terminal that has no influence on the spanning tree configuration.
Exit to global configuration mode.
Exit to administrator EXEC mode.
View the state of the spanning tree.
40/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.7 VLAN
VLAN (Virtual LAN) is a technology that divides a single network into virtually separated networks.
VLANs are separate logical networks within one physical network. A VLAN capable switch can change and define new LAN network configurations without changing physical cable connections. This creates a flexible and extensible network system.
The device provides for port-based or tag-based (IEEE802.1Q) VLANs.
4.7.1 Port-Based VLAN
Port-based VLAN is a method for configuring VLAN membership on a port basis. Forwarding is based on the destination MAC addresses and related port. xg(config)# vlan-statistics collection <1-4094>
[ <1-4094> ] xg(config)# interface port 1 2 3
(interface port range 1 3) xg(config-if)# port-vlan-id vlan <1-4094> xg(config-if)# ingress-filter tagged-frame xg(config-if)# ingress-filter untagged-frame xg(config-if)# exit xg(config)# exit xg# show interface xg# show vlan
To configure a port-based VLAN, carry out the following procedures in the administrator EXEC mode.
Command Task
xg# configure terminal xg(config)# vlan <1-4094> [ description
Switch to global configuration mode.
Create a VLAN to use.
VLAN_DESCRIPTION ]
(Optional)
Configure a VLAN that collects statistics.
Switch to interface edit mode to assign a port to the desired port-based VLAN.
In this example, the global interface configuration mode is selected for ports 1 through 3.
Set the default port VLAN ID for each port.
(Optional)
Define a filter on frames received (tagged and untagged frames) if necessary.
Exit to global configuration mode.
Exit to administrator EXEC mode.
Verify the port state.
Check the information displayed in [Port Default Vlan
ID] under command output [Vlan Information].
Verify the port VLAN membership.
41/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.7.2 Tag-Based (IEEE802.1Q) VLAN
Tag-based VLAN is a method of configuring VLANs so that the frame forwarding decision is based on a tag in the MAC header identifying the VLAN membership. 4 bytes of additional data in the header, called a VLAN tag, identifies the VLAN frame ownership. Using a VLAN tag enables configuring a single physical link that shares multiple VLANs.
The device’s tag-based VLAN function is based on the IEEE 802.1Q standard.
The following figure shows an Ethernet frame format including a VLAN tag as specified by the IEEE 802.1Q standard. xg(config)# vlan-statistics collection <1-4094>
[ <1-4094> ] xg(config)# interface port 1 2 3
(interface port range 1 3) xg(config-if)# vlan-member allowed vlan
To configure a tag-based VLAN, carry out the following procedures in the administrator EXEC mode.
Command Task
xg# configure terminal xg(config)# vlan <1-4094> [ description
Switch to global configuration mode.
Create a VLAN to use.
VLAN_DESCRIPTION ]
(Optional)
Configure a VLAN that collects statistics.
Switch to interface edit mode for the desired ports to be configured as tag-based VLAN members.
In this example, the global interface configuration mode is selected for ports 1 though 3.
Register VLAN port ownership.
{ <1-4094> | all }
{ egress-untagging | egress-tagging } xg(config-if)# ingress-filter tagged-frame xg(config-if)# ingress-filter untagged-frame xg(config-if)# exit xg(config)# exit xg# show vlan
(Optional)
Define a filter for frames received (tagged and untagged frames) at the ports, if necessary.
Exit to global configuration mode.
Exit to administrator EXEC mode.
View the port's VLAN membership state.
42/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.7.3 Multiple VLAN
With the user-defined VLAN tag protocol identifier, the IEEE 802.1Q standard tag can be replaced with a user-defined VPID, allowing for encapsulation of multiple tags for multiple-tagged VLANs. The standard tag identifier or TPID is 0x8100 as defined in IEEE 802.1Q.
For the frame format, refer to TPID (Tag Protocol Identifier) in "
Using multiple VLAN (also known as double tagging or Q-in-Q) allows a service provider to transparently forward customers'
VLAN traffic even if the service provider assigns customer traffic to different VLANs.
To configure multiple VLAN using a user-defined VLAN tag protocol identifier, carry out the following procedures in the administrator EXEC mode.
Command
xg# configure terminal xg(config)# vlan <1-4094> [ description
Create a VLAN to use.
Task
Switch to global configuration mode.
VLAN_DESCRIPTION ] xg(config)# vlan-statistics collection <1-4094>
[ <1-4094> ]
(Optional)
Configure a VLAN that collects statistics. xg(config)# interface port 1 xg(config-if)# user-vlan-protocol-id <0x05DD ~
Switch to interface edit mode to designate a port for multiple VLAN configuration.
In this example, the global interface configuration mode is selected for port 1.
Set the user-defined VLAN tag protocol identifier.
0xFFFF> xg(config-if)# vlan-member allowed vlan
{ <1-4094> | all }
{ egress-untagging | egress-tagging } xg(config-if)# ingress-filter tagged-frame xg(config-if)# ingress-filter untagged-frame xg(config-if)# exit xg(config)# exit xg# show interface xg# show vlan
Register the port to the VLAN.
Specify "egress-tagging" for tagged output at the port.
Specify "egress-untagging" for the port untagged output at the port.
(Optional)
Define a filter for frames received (tagged and untagged) for the port, if necessary.
Exit to global configuration mode.
Exit to administrator EXEC mode.
Verify the port state and VLAN membership state for each port.
43/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
An example of multiple VLAN and the movement of frames for a VLAN member outgoing port (VLAN-tagged frame), is shown below.
An example of multiple VLAN and the movement of frames for a VLAN member outgoing port (VLAN-untagged frame), is shown below.
44/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
An example of multiple VLAN and the movement of frames when the user-defined VPID of the incoming and outgoing port differ and the outgoing port is a VLAN member (VLAN-tagged frame), is shown below.
An example of multiple VLAN and the movement of frames when the user-defined VPID of the incoming and outgoing port differ and the outgoing port is not a VLAN member (VLAN-untagged frame), is shown below.
45/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.8 Quality of Service (QoS)
The device provides Quality of Service (QoS) that is based on the IEEE802.1p standard.
The device QoS determines the priority of frames at the ingress side using DiffServ, VLAN tag (including priority tag) or a port's default priority. Their priorities are mapped to 4 output queues. The queues are processed in the order of the QoS priority precedence.
The device priorities available are:
DiffServ
Select QoS using the IPv4 header or DiffServ Code Point included in the IPv6 header.
Default priority
Set a default priority of 0 to 7 for each port.
For frames whose priority was not set (VLAN-untagged frames), the default priority is assigned according to the value of the frame.
Mapping to output queues
The device is equipped with four output queues with different levels (0 to 3). Frames are transmitted in order of output queue priority.
Each priority is mapped to a specified output queue.
To set the default priority and output queue mapping, carry out the following procedure in the administrator EXEC mode.
Command Task
xg# configure terminal xg(config)# interface port 1 2 3 xg(config)# interface port range 1 3 xg(config-if)# qos default-priority <0-7>
Switch to global configuration mode.
Switch to interface edit mode and specify the port(s) to set with a default QoS priority.
In this example, the global interface configuration mode is selected for ports 1 though 3.
Set a default priority for frames whose priority was not set (VLAN-untagged frame) when received. xg(config-if)# exit
Exit to global configuration mode. xg(config)# bridge diffserv-tos {ipv4 | ipv6}
(Optional)
Used to enable QoS based on DiffServ Code Point. xg(config)# qos-map priority <0-7>
output-priority <0-3>
Set the level of output queue to map to each frame that has a priority value. xg(config)# exit xg# show qos [ qos-map ]
Exit to administrator EXEC mode.
Show the QoS setting status.
46/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.9 IGMP Snooping
IP multicast is often used to distribute multimedia data, including video and voice, over a network.
A layer 2 switch floods multicast frames, absorbing unnecessary network bandwidth. A layer 3 switch that supports Internet
Group Management Protocol (IGMP) manages multicast groups using IGMP packets. The device controls how IP multicast packets are forwarded to required ports by monitoring IGMP packets generated by layer 3 switches, thereby preventing unnecessary flooding. This function is called "IGMP Snooping".
The device supports IGMP snooping for IGMP v1/v2/v3.
IGMP v3 does not support source IP addressing and filtering.
IGMP snooping and the uplink filter function cannot be used at the same time.
The XG2000 series floods IGMP Report messages. When IGMP v1/v2 is used, it is necessary to connect a device, such as a L3 switch, that supports IGMP snooping between the XG2000 series and the IGMP hosts in order to avoid flooding.
It is necessary to set forward-unregistered-mac or filter-unregistered-mac when IGMP snooping is used.
47/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.9.1 Registering Group Members
On receiving an IGMP Report message, the device registers a multicast MAC address with the MAC address table for the port that received the IGMP Report message and the connecting multicast router port.
The following figure shows the relationship between the registered IP multicast address and the multicast MAC address.
MAC addresses that are registered with IGMP snooping are between 0100.5E00.0000 and 0100.5E7F.FFFF. An IP multicast address is 32 bits. The first 4 bits are always 1110 followed by 28 bits that represent the IP multicast address information. Of these 28 bits, the lower order 23 bits are mapped to a MAC address and the data in the higher order 5 bits is not used.
Therefore 32 IP multicast addresses are mapped to the same single MAC address.
48/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.9.2 Removing Group Members
The group members registered by IGMP snooping are removed under the following status.
If after receiving an IGMP Report message for group registration, the group member interval expires before the device receives another IGMP Report message, the switch removes that group member. The default setting for the group member interval is 260 seconds.
If an IGMP Leave message is sent from a host, the multicast router sends out an IGMP Specific Query (GSQ) message to determine that the host has left the group.
If after receiving the IGMP Leave message, the last member query interval expires before the device receives another
IGMP Report message, the switch removes that group member. The default setting for the last member query interval is 2 seconds.
49/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.9.3 Managing Group Members
When network congestion causes Leave message loss or there is a host that uses IGMPv1, the multicast router does not receive Leave messages. The multicast router sends out an IGMP General Query message to all hosts (IP address: 224.0.0.1) at intervals (query interval) to determine membership information.
Upon reception of an IGMP General Query message, the host, a member of the group, returns an IGMP Report message to maintain membership in the group.
In consideration of General Query or Report message loss caused by network congestion, it is recommended that the following equation be used to determine the group member interval for the device.
Group member interval = (query interval for multicast router)
× 2 + 10 (seconds)
Since RFC 3376 defines the default query interval for multicast routers as 125 seconds, the device uses 260 seconds for the default group member interval.
50/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.9.4 IGMP Querier
In a typical network configuration, the multicast router periodically sends out an IGMP General Query message to determine if any of the hosts on the network are members of any multicast groups. Receiving a response from a host ascertains its membership in a multicast group.
IGMP Querier is a function that acts as a proxy for a multicast router when one is not available in a network segment to send an IGMP General Query message to all hosts.
The frequency of Query messages issued is configured using the "ip snooping vlan send-query-count" command.
The frequency of the General Query messages sent (query interval) are automatically calculated by the following equation based on the send query count and the group membership interval.
Query interval = (Group membership interval - 10)/send query count (seconds)
The default setting for the Query interval is 125 seconds.
Upon reception of an IGMP Leave message, the device sends an IGMP Specific Query (GSQ) message to determine that the host is interested in leaving the group.
If an IGMP Specific Query message is sent as many times as specified by the send query count and the host does not respond with an IGMP Report message, that host is removed.
Generally, IGMP Querier uses "0.0.0.0" for the source IP address when sending a Query message.
Since some client software does not return a response for a Query message with the source IP address being set to "0.0.0.0", it is recommended that an address other than "0.0.0.0" be used.
If a multicast router exists on the network segment, the device does not send Query message even if
IGMP Querier is valid.
51/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.9.5 Configuring IGMP Snooping
To configure IGMP snooping, carry out the following procedure in the administrator EXEC mode.
Command Task
xg# configure terminal xg(config)# ip snooping protocol igmp
Switch to global configuration mode.
Enable global IGMP snooping on the device. xg(config)# ip snooping vlan <1-4094> xg(config)# ip snooping vlan <1-4094>
group-member-interval <60-600> xg(config)# ip snooping vlan <1-4094>
mrouter { port <1-20> | agg-port <1-10> } xg(config)# ip snooping vlan <1-4094>
mrouter suppress-learning xg(config)# ip snooping vlan <1-4094>
last-member-query-interval <1-9> xg(config)# ip snooping vlan <1-4094>
send-query-count <1-3> xg(config)# ip snooping vlan
max-group <10-128>
Enable IGMP snooping for each VLAN separately.
(Optional)
Change the group member interval.
(Optional)
Register the port the multicast router resides statically.
(Optional)
Suppress dynamic registration on the port the multicast router resides.
(Optional)
Change the last member query interval.
(Optional)
Change the frequency of Query messages sent.
(Optional)
Change the number of multicast addresses that can be registered with IGMP snooping for each VLAN. xg(config)# ip snooping vlan <1-4094>
fast-leave sw(config)# interface port range 1 20
(Optional)
Set the fast-leave mode used when receiving an IGMP Leave message.
Switch to interface edit mode to designate ports to specify the forwarding method for multicast frames.
All ports are selected in this example. sw(config-if)# multicast-forwarding Set forwarding method for multicast frames to
forward-unregsitered-mac xg(config)# exit forward-unregistered-mac.
Exit to administrator EXEC mode.
To enable IGMP query, carry out the following procedure in the administrator EXEC mode.
Command Task
xg# configure terminal xg(config)# ip snooping protocol igmp
Switch to global configuration mode.
Enable global IGMP snooping on the device. xg(config)# ip snooping vlan <1-4094> xg(config)# ip snooping vlan <1-4094>
group-member-interval <60-600> xg(config)# ip snooping vlan <1-4094>
last-member-query-interval <1-9> xg(config)# ip snooping vlan <1-4094>
send-query-count <1-3> xg(config)# ip snooping vlan <1-4094>
querier ip A.B.C.D xg(config)# exit
Enable IGMP snooping for each VLAN separately.
(Optional)
Change the group member interval.
(Optional)
Change the last member query interval.
(Optional)
Change the frequency of Query messages sent.
Enable IGMP query and set the source IP address for a Query message.
Exit to administrator EXEC mode.
52/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.10 Network Management
4.10.1 Traffic Statistics
The device can display traffic statistics to analyze network operations such as traffic bytes, errors, etc.
The following are the Traffic Statistics the device provides.
Displays traffic information on outgoing and incoming frames for each port.
Displays traffic information on incoming frames by frame size range for each port.
Displays traffic information on incoming frames for each VLAN.
Displays incoming traffic information by QoS priority for each port.
Displays information related to data flow for each port.
Displays information about errors that occur during transmission/reception for each port.
To display traffic statistics, monitor and show commands are provided.
"monitor" command
Displays real-time traffic statistics.
"show statistics" command
Outputs details of the current accumulated traffic statistics.
Enter this command followed by "> FILE_NAME" or "| redirect FILE_NAME" to output the results to a file in volatile memory.
To display traffic statistics, run the following commands in the operator EXEC mode or in the administrator EXEC mode.
Command
xg> monitor traffic-counts
{ current | total } [interval <3-60>]
Task
View incoming and outgoing traffic statistics (number of frames and number of bytes) for each port. xg> monitor traffic-bytes
{ current | total } [interval <3-60>] xg> show statistics traffic-counts xg> show statistics traffic-bytes xg> monitor framesize-traffic-counts
{ current | total } [interval <3-60>]
View traffic statistics (number of frames) by frame size range for each port. xg> show statistics framesize-traffic-counts xg> monitor vlan-traffic-counts
{ current | total } [interval <3-60>] xg> monitor vlan-traffic-bytes
{ current | total } [interval <3-60>]
View traffic statistics (number of frames and number of bytes) on incoming frames for each VLAN. xg> show statistics vlan-traffic-counts xg> show statistics vlan-traffic-bytes xg> monitor qos-priority-traffic-counts
{ current | total } [interval <3-60>] xg> monitor qos-priority-traffic-bytes
{ current | total } [interval <3-60>]
View incoming traffic statistics (number of frames and number of bytes) by QoS priority for each port. xg> show statistics
qos-priority-traffic-counts xg> show statistics
qos-priority-traffic-bytes xg> monitor dataflow
{ current | total } [interval <3-60>] xg> show statistics dataflow xg> monitor error
{ current | total } [interval <3-60>] xg> show statistics error xg> enable xg# clear statistics
View traffic statistics (number of frames) related to data flow during frame forwarding for each port.
View information about errors that occur during transmission/reception for each port.
Clear cumulative traffic statistics collected after system startup.
53/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
4.10.2 SNMP Agent
SNMP (Simple Network Management Protocol) is a protocol that monitors and manages devices on a network.
The device supports the SNMP (v1/v2c) function to collect management information blocks (MIBs) from a remote network manager (SNMP manager). For operations via SNMP manager, only read-only operations are allowed. For the MIBs supported, refer to Appendix C. The device can be configured for up to 4 SNMP managers and up to 4 SNMP trap destinations.
To configure the SNMP agent, carry out the following procedures in the administrator EXEC mode.
Command Task
xg# configure terminal xg(config)# hostname HOST-NAME xg(config)# snmp-server location SYSTEM-LOCATION
Switch to global configuration mode.
Set the system name (HOST-NAME), system's location
(SYSTEM-LOCATION), and contact (SYSTEM-CONTACT). xg(config)# snmp-server contact SYSTEM-CONTACT xg(config)# snmp-server access host HOST
community COMMUNITY-NAME xg(config)# snmp-server trap host HOST
community COMMUNITY-NAME [protocol {v1|v2c}] xg(config)# exit
Set the IP address (host name) of the SNMP manager and the community name.
Set the SNMP trap receiver IP address (host name) and the community name.
Exit to administrator EXEC mode.
4.10.3 RMON
Remote Monitoring (RMON) is a function provided to monitor communications over a network, such as traffic and errors.
RMON, used in conjunction with the SNMP agent, allows the remote monitoring of traffic on a LAN segment.
The device supports 4 RMON groups (Statistics, History, Alarm and Event).
Statistics group
Collects traffic statistics for each port.
History group
Records traffic statistics for each port at specified time intervals.
Alarm group
Monitors MIBs at specified time intervals and, if the monitored MIB object value exceeds or falls below a specified threshold, a RMON event is executed.
Event group
Specifies an event operation that is executed by an alarm. Possible event operations include creation of a log entry and generation of a SNMP trap.
To configure RMON, carry out the following procedure in the administrator EXEC mode.
Command
xg# configure terminal
Task
Switch to global configuration mode. xg(config)# rmon collection history <1-65535>
port <1-20> [buckets <1-20>] [interval <1-3600>]
(Optional)
Enable a RMON history group.
[owner OWNERNAME] xg(config)# rmon alarm <1-65535> VARIABLE
interval <2-65535> {absolute | delta}
(Optional)
Enable a RMON alarm group.
rising-threshold <0-2147483647> [<1-65535>]
falling-threshold <0-2147483647> [<1-65535>]
[owner OWNERNAME] xg(config)# rmon event <1-65535> [log]
[trap COMMUNITY] [description
(Optional)
Enable a RMON event group.
DESCRIPTION-STRING]
[owner OWNERNAME] xg(config)# exit
Exit to administrator EXEC mode.
54/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Chapter 5 Command Reference
55/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.1 About Command Reference
This section describes how to read command references.
5.1.1 Command System
The following is the system of commands provided in the device:
Item
Management LAN Interface Configuration commands
Serial/telnet/ssh configuration commands
Function
These are used to configure functions related to the management LAN interface.
These are used to configure functions related to serial, telnet and ssh connections.
System Basic Operation commands
Configuration Information Operation commands
Switch Basic Configuration commands
Link Aggregation Configuration commands
Switch Port Configuration commands
Spanning Tree Protocol (STP) Setup commands
These are necessary commands for system operation such as the system time setting, password setting, and file operations.
These are used for displaying or saving configuration information
(running-config and startup-config) in the device.
These are used to configure the basic functions of the device.
These are used to create/delete aggregation groups.
These are used to set the operating characteristics of each switch port.
These are used to configure STP (Spanning Tree Protocol).
Virtual LAN (VLAN) Configuration commands These are used to configure virtual LAN (VLAN).
Quality of Service (QoS) Setup commands These are used to configure QoS (Quality of Service) configuration.
Port Mirroring Setup commands
IGMP Snooping Setup commands
These are used to configure port mirroring.
These are used to configure IGMP Snooping.
Statistics commands
SNMP Configuration commands
RMON Configuration commands
System Status Display commands
Maintenance commands
These are used to display various operational statistics.
These are used to configure SNMP.
These are used to configure RMON.
These are used to display the system status of the device and the operational status of its hardware.
These are necessary for maintenance of the device.
56/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.1.2 Configuration of Command Reference
This section describes the configuration of command reference and descriptive content.
Function
Explains the functions of the commands.
Prompt
Indicates the prompt of the operational mode.
Command syntax
Describes the command syntax. The notation of the command syntax is as follows:
Notation
Lower-case characters
Meaning
Indicate fixed strings such as command names and keyword names.
Indicate parameters specifying any strings.
Indicate omissible parameters.
Example of description
enable delete FILE-NAME date [ YYYYMMDD-hhmmss ]
Upper-case characters
[ ]
(Enclosed in a pair of square brackets)
{ | }
(Enclosed in a pair of curly brackets with a vertical line in-between)
< >
(Enclosed in a pair of angle brackets)
Indicate parameters wherein at least one alternative must be chosen.
Indicate parameters with a condition of numerical range. baudrate
{ 9600|19200|38400|57600 } interface port <1-20>
Parameter
Explains how to specify command parameters, and their meanings.
Command type
Indicates configuration commands that retain configuration information in startup-config and running-config or operation management commands that are related to configuration of the device, such as status display or time setting.
Default
Indicates the factory default of this command.
Output form
Explains the meaning of output (or input) results, when there is a command output (or input).
Message
Explains messages displayed when executing a command, their solution, and significance.
Note
Explains notes for commands.
Example
Describes how to use commands, using examples.
57/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.2 Management LAN Interface Configuration Commands
This section explains configuration commands related to the Management LAN Interface.
5.2.1 show remote-host
Function
Displays the relationship between the remote hostname and IP address.
Prompt
xg> or xg#
Command syntax
show remote-host
Command type
Operation management commands.
Output form
sw# show remote-host
Remote Host 2008/02/05-11:37:34
================================
IP Address Host Name
--------------- --------------------------------------------------------------
11.22.33.45 HOST005
11.22.33.46 HOST006
IP Address
Display the IP address of remote host
Host Name
Display the hostname which is related to the IP address
Example
Display the list of hostname and the IP address. xg# show remote-host
58/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.2.2 management-lan ip
Function
Sets the IP address and default gateway, when the Management LAN Interface is used.
Use the no form to disable the Management LAN Interface.
Prompt
xg(config)#
Command syntax management-lan ip A.B.C.D/M [default-gw A.B.C.D] no management-lan ip
Parameter
ip A.B.C.D/M
Specifies the IP address and subnet mask bit length of the Management LAN Interface in the
A.B.C.D/M format.
Specifies an IP address of A.B.C.D, and a subnet mask bit length to M.
IP addresses that can be set are: 1.0.0.1 - 126.255.255.254, 128.0.0.1 - 191.255.255.254, and 192.0.0.1 - 223.255.255.254. default-gw A.B.C.D
Specifies the IP address of the default gateway.
Command type
Configuration command
Default
192.168.0.2/24
Message
% Invalid IP-address.
Explanation
The specified format of the IP address or specified content is incorrect.
Solution
Specify the IP address in a correct format and execute the command again.
Note
When the IP address is changed from a telnet/ssh terminal using this command, the telnet/ssh connection will be disconnected. Connect again with a new address.
Example
Make the Management LAN Interface usable by setting IP address to "12.34.56.25," subnet mask bit length to "24"
(255.255.255.0), and default gateway address to "12.34.56.1". xg(config)# management-lan ip 12.34.56.25/24 default-gw 12.34.56.1
59/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.2.3 management-lan dns-server
Function
Registers the IP address of a DNS (Domain Name Service) server used for host name resolution. Up to three DNS servers can be registered.
Use the no form to delete registered DNS servers.
Prompt
xg(config)#
Command syntax management-lan dns-server A.B.C.D no management-lan dns-server [A.B.C.D]
Parameter
dns-server A.B.C.D
Sets the IP address to register as a DNS server in A.B.C.D format.
IP addresses that can be set are: 1.0.0.1 - 126.255.255.254, 128.0.0.1 - 191.255.255.254, and 192.0.0.1 - 223.255.255.254.
(no management-lan) dns-server [A.B.C.D]
Deletes registered DNS server(s). Specifies IP address in A.B.C.D format.
When IP address is omitted, all registered DNS servers will be deleted.
Command type
Configuration command
Default
None
Message
% Not exist IP-address of DNS server
Explanation
The specified IP address is not found.
Solution
Specify the IP address of a registered DNS server.
% Number of DNS server is over (max=3)
Explanation
The upper limit of the number of registrable DNS servers was surpassed.
Solution
After deleting unnecessary DNS server information, execute the command again.
% Invalid IP-address.
Explanation
The specified format of the IP address or specified content is incorrect.
Solution
Specify the IP address in a correct format and execute the command again.
Note
Since DNS server(s) connect via the Management LAN Interface, the Management LAN Interface must be configured beforehand via the management-lan ip command.
If DNS server is registerd, the new setting becomes enabled after executing “copy running-config startup-config” command and restart the device.
Example
Register DNS servers with IP addresses "12.34.56.76" and "12.34.56.77". xg(config)# management-lan dns-server 12.34.56.76 xg(config)# management-lan dns-server 12.34.56.77
Delete all registered DNS servers. xg(config)# no management-lan dns-server
60/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.2.4 management-lan domain
Function
Sets the default domain name when referring to a DNS (Domain Name Service) server.
For example, when the host name is "hostname1," and "abc.jp" is specified as the default domain name, perform a search for the address with an FQDN (Fully Qualified Domain Name) of "hostname1.abc.jp."
Use the no form to delete the set domain name.
Prompt
xg(config)#
Command syntax management-lan domain DOMAIN-NAME no management-lan domain
Parameter
domain DOMAIN-NAME
Specifies the default domain name.
Follow these rules for specifying a domain name:
− Characters usable for the name
Alphabet ([a - z], [A - Z]), numerical characters ([0 - 9]), hyphen (-), and period (.)
− First character
Alphabet ([a - z], [A - Z])
− Last character
Alphabet ([a - z], [A - Z]), numerical characters ([0 - 9]), and period (.)
Command type
Configuration command
Default
None
Note
If the default domain name is changed, the new setting becomes enabled after executing “copy running-config startup-config” command and restart the device.
Example
Specify "corp.co.jp" for the default domain name of a DNS server.
Then, return to the operator exec mode, specify "hostname1" for a TFTP server name, and execute the "tftp" command. The default domain name is added to "hostname1," and the IP address can be referenced from the DNS server with the FQDN name of "hostname1.corp.co.jp." xg(config)# management-lan domain corp.co.jp xg(config)# exit xg# tftp get hostname1 remotefile localfile
61/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.2.5 hostname
Function
Changes the hostname of the device.
Use the no form to return to the default ("xg").
Prompt
xg(config)#
Command syntax hostname HOST-NAME no hostname
Parameter
HOST-NAME
Specifies the hostname of the device. Specify the hostname using 63 characters or less, with an alphabet character at the beginning.
Follow these rules for specifying the hostname:
− Characters usable for the name
Alphabet ([a - z], [A - Z]), numerical characters ([0 - 9]), hyphen (-), and period (.)
− First character
Alphabet ([a - z], [A - Z])
− Last character
Alphabet ([a - z], [A - Z]), numerical characters ([0 - 9]), and period (.)
Command type
Configuration command
Default
"xg"
Example
Specify the hostname of the device to be "xg2."
The prompt will change to "xg2."
Switching to the administrator exec mode and displaying the system status will confirm that the System Name was changed to
"xg2." xg(config)# hostname xg2 xg2(config)# exit xg2# show system information
System Information 2007/01/22-11:04:54
=======================================
System Name (hostname) : xg2
System Location : (none)
62/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.2.6 remote-host
Function
Registers remote host information and shows the relationship between the remote hostname and IP address.
By registering the IP address of a remote host that is used frequently, the name can be specified instead of the IP address. The relationship between the registered hostname and IP address is given priority over the DNS server configuration.
Use the no form to delete registered remote host information.
Prompt
xg(config)#
Command syntax remote-host A.B.C.D HOST-NAME no remote-host [ A.B.C.D ]
Parameter
A.B.C.D
Specifies the IP address of a remote host in A.B.C.D format.
IP addresses that can be set are: 1.0.0.1 - 126.255.255.254, 128.0.0.1 - 191.255.255.254, and 192.0.0.1 - 223.255.255.254.
HOST-NAME
Specifies the remote hostname to register. Specify the hostname using 63 characters or less, with an alphabet character at the beginning.
Follow the rules below for the hostname and domain name:
− Characters usable for the name
Alphabet ([a - z], [A - Z]), numerical characters ([0 - 9]), hyphen (-), and period (.)
− First character
Alphabet ([a - z], [A - Z])
− Last character
Alphabet ([a - z], [A - Z]), numerical characters ([0 - 9]), and period (.)
(no remote-host) [A.B.C.D]
Deletes the registered remote host. Specify the IP address in A.B.C.D format.
When IP address is omitted, all registered remote hosts will be deleted.
Command type
Configuration command
Default
None
Message
% Invalid IP-address.
Explanation
The specified format of the IP address or specified content is incorrect.
Solution
Specify the IP address in a correct format and execute the command again.
% Number of remote-host is over (max=10)
Explanation
The upper limit of the number of registrable remote hosts was surpassed.
Solution
After deleting unnecessary hosts, execute the command again.
% Already exist name of remote host
Explanation
A remote hostname with the same IP address was previously registered.
Solution
Change the remote hostname of the IP address to the correct name, or register it again after deleting it.
% Not exist IP-address of remote host
Explanation
The specified host definition is not registered.
Solution
Specify a registered IP address and execute the command again.
63/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Example
Register the IP address "11.22.33.45" as the hostname of "HOST005," and then "11.22.33.46" as the hostname of "HOST006."
Using the show remote-host command, registration of "HOST005" and "HOST006" can be confirmed. xg(config)# remote-host 11.22.33.45 HOST005 xg(config)# remote-host 11.22.33.46 HOST006 xg(config)# exit xg# show remote-host
Remote Host 2007/01/22-11:45:46
================================
IP Address Host Name
---------- -----------------------------------------
11.22.33.45 HOST005
11.22.33.46 HOST006
64/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.3 Serial/Telnet/ssh Configuration Commands
This section explains configuration commands related to a serial connection/telnet/ssh connection.
5.3.1 terminal pager
Function
Enables or disables the pager function of the serial/telnet/ssh terminal.
Prompt
xg> or xg#
Command syntax terminal pager { on | off }
Parameter
pager { on | off }
Specifies enable/disable of the pager.
− on
Enables the pager.
− off
Disables the pager.
Command type
Operation management commands
Default
on
Note
This command is effective until the terminal is disconnected.
5.3.2 line
Function
Switches to the terminal edit mode
Prompt
xg(config)#
Command syntax line console
Parameter
console
Switches to the terminal edit mode of the serial connection.
Command type
Configuration command
Example
Switch from the administrator exec mode to the terminal edit mode with the serial interface. xg# configure terminal xg(config)# line console
65/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.3.3 baud-rate
Function
Sets the serial baud rate (bps).
Prompt
xg(config-line)#
Command syntax baud-rate { 9600 | 19200 | 38400 | 57600 }
Parameter
{ 9600 | 19200 | 38400 | 57600 }
Specifies any of 9600/19200/38400/57600 as the serial baud rate (bps).
Command type
Configuration command
Default
9600
Note
When the serial baud rate is newly set, it will become valid after logging out of the serial terminal session and re-connecting.
Example
Switch from the global configuration mode to the terminal edit mode using the "line console" command. And then change the serial baud rate to 38400bps. xg(config)# line console xg(config-line)# baud-rate 38400
5.3.4 terminal timeout
Function
Sets the monitoring idle time for a serial connection, or telnet and ssh connections.
When there is no operation from the terminal within the monitoring time specified with this command, the terminal will be logged out automatically.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax terminal timeout { console | vty } <0-60> no terminal timeout { console | vty }
Parameter
timeout { console | vty }
Specifies the type of the terminal.
− console
Sets the monitoring idle time for a serial connection.
− vty
<0-60>
Sets the monitoring idle time for a telnet and ssh connections.
Specifies the monitoring idle time. Specified in the range of 0 to 60 minutes.
When 0 is specified, no-operation monitoring is performed, and the terminal will not be logged out automatically.
Command type
Configuration command
Default
10 minutes
Note
While the "monitor" command or the "update-system" command is being executed, no-operation monitoring is deterred.
Example
Set the monitoring idle time for the serial connection, and Telnet and ssh connections to 10 minutes and 5 minutes respectively. xg# configure terminal xg(config)# terminal timeout console 10 xg(config)# terminal timeout vty 5
66/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.3.5 telnet-server
Function
Enables telnet connections with the device.
Use the no form to disable telnet connections.
Prompt
xg(config)#
Command syntax telnet-server no telnet-server
Command type
Configuration command
Default
Disabled
Example
Enable telnet connections to the device. xg(config)# telnet-server
5.3.6 ssh-server
Function
Enables ssh connections with the device. Up to 4 terminal sessions can access the device concurrently.
Use the no form to disable ssh connections.
Prompt
xg(config)#
Command syntax ssh-server no ssh-server
Command type
Configuration command
Default
None
Note
The device supports only password authentication.
The device supports only version 2.
Example
Enable ssh connections to the device. xg(config)# ssh-server
5.3.7 ssh-auto-key-generation
Function
Regenerate authentication key when enables ssh connection.
Use the no form not to regenerate authentication key.
Prompt
xg(config)#
Command syntax ssh-auto-key-generation no ssh-auto-key-generation
Command type
Configuration command
Default
None
Example
The following enables to regenerate authentication key. xg(config)# ssh-auto-key-generation
67/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.3.8 show ssh-host-key
Function
Shows authentication key.
Prompt
xg> or xg#
Command syntax show ssh-host-key
Command type
Operation management commands
Output form
xg# show ssh-host-key
SSH Host Key 2007/09/07-17:10:33
=============================================================================== ssh-dss AAAAB3NzaC1kc3MAAACBALZunL9ymdBEx4QFOsKhwwCf7WpCwpLne6ZNgc7keG/2Yf0OY4Yx
MwOgf1Dm5SSaN/pSdfKotT/zN3ywpDQywlNVjNxF7IYk/p3Q/jABPa245A1Mu9l9a8IiOZhV+w0vMI8N vTi4Cqk2S+tSDzf2vXQ58KCAijeyGDrEi71bZPgbAAAAFQDjkiO5/EupRfrKMc2HHpM7OWtF+QAAAIBR c1CGq9Wt60LV6DkzrYhLNcRgkRNi/XFARzyyFX3TWm2LPBDd8/nbp3zc+N5poNKHBJ/61somWzqKVrTA nR/AQDEyftltVgr4vWn1IDEtu6IZzShZGfgFDk2aZIVP3jFr0BEz5GV+eoGkQb4Be3qJHKiomIjNi+As vrSYfBqSnQAAAIBj+rJ2lZcTRtzgkmeJvjf0q52sHFL+zSC27e24c/BU7V+Hr2xw50I+bVZNbxHGMWtb
Ma9mQmBbKmotWq8wRxHluBsQ/5ZktlQrT60M0F8zF+vBFYV3PPG+LvpA8MTYDvjXkZ7w0ZypU/ShRqiZ
R8X0wyVvA2GoBCiPlXj1VfmZHA== admin@xg ssh-rsa AAAAB3NzaC1yc2EAAAABIwAAAQEA1qtD/sBupdj89yRApm2o3pZCpaodDwljdmgW8iBfmtmO
SUnLYcszHW+dNTg7QXeoEyU+MyZMzYxQH1kABB3Wl+rfP0dZ7Ri4nCm+fYWN6QCX8M5hHVuALz5ITmBA sWxhQUvxDxI+VdpUB3ta4xgKiPOMFfVBjdr4M6Upr9+jaVG6pyWCDGtkEL4qbLUXTx1XqFsNtuLwembg
ZUWTXo3cU6BXZ2B+wo8mpgsvcabcN1gZiTycAs3WIj/0V8lp0hglQKsfOqIF8b9pNWEi2NqIMbDSG+yz
BzXNqwg6IbpCUMxdBMeij97YafJTl1+h5zJvxP2AsrannGlIdeYJxXYaWQ== admin@xg
===============================================================================
Example
The following shows authentication key. xg# show ssh-host-key
5.3.9 generate ssh-host-key
Function
Generate authentication key. If it has already been made, it is regenerated.
Prompt
xg#
Command syntax generate ssh-host-key
Command type
Operation management commands
Example
The following generates authentication key. xg# generate ssh-host-key
68/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.3.10 terminal window
Function
Sets the screen display size of the serial connection terminal.
Use the no form to return to the default setup.
For a telnet or ssh connection, the screen size will be obtained automatically from the client terminal.
Prompt
(config-line)#
Command syntax terminal window <50-200> <12-100>
Parameter
<50-200>
Specifies the number of columns (horizontal) of the screen. It can be set in the range of
50 to 200.
<12-100>
Specifies the number of lines (vertical) of the screen. It can be set in the range of 12 to 100.
Command type
Configuration command
Default
80 columns by 24 lines
69/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.4 System Basic Operation Commands
This section explains the basic commands of the device CLI (Command Line Interface).
5.4.1 enable
Function
Switches from the operator exec mode to the administrator exec mode.
When a password is set for the "enable" command, a password is required. When there is an error in entering the password, re-entering the password will be allowed up to three times. Additionally, after successful authentication of the password, for a given login session, the user will not be prompted for the password until they exit the administrator exec mode and re-enter the mode.
Prompt
xg>
Command syntax enable
Command type
Operation management commands
Example
Switch from the operator exec mode to the administrator exec mode using the "enable" command.
The prompt character will change to "xg#." xg> enable xg#
When a password is set for the "enable" command, enter the password.
When password authentication is successful, control switches to the administrator exec mode, and the prompt character will change to "xg#." xg> enable
Password:
←Enter the password to "enable." xg#
(The entered password is not displayed.)
70/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.4.2 show history
Function
Displays the history of executed commands since logged into the device.
Prompt
xg> or xg#
Command syntax show history
Command type
Operation management commands
Output form
xg# show history
1 enable
2 show system information
3 date
4 show system information
5 show history
Note
If the same command is executed continuously, it is treated as one command.
Up to 100 history will be displayed.
Example
Displays the history of executed commands. xg# show history
5.4.3 disable
Function
Switch from the administrator exec mode to the operator exec mode.
Prompt
xg#
Command syntax disable
Command type
Operation management commands
Example
Switch from the administrator exec mode to the operator exec mode using the "disable" command.
The prompt character will change to "xg>." xg# disable xg>
71/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.4.4 configure terminal
Function
Switch from the administrator exec mode to the global configuration mode.
Prompt
xg#
Command syntax configure
terminal
Command type
Operation management commands
Message
Configuration is locked by other.
Explanation
A switch in state is not possible because a terminal session in global configuration mode exists.
Solution
After switching the terminal session from global configuration mode to administrator
EXEC mode, re-execute the command.
Example
Switch from the administrator exec mode to the global configuration mode using the "configure terminal" command.
The prompt character will change to "xg(config)#." xg# configure terminal xg(config)#
5.4.5 exit
Function
Returns to the prior command mode level.
The relationship between the current command mode and the command mode status after executing the "exit" command is as follows:
Current command mode
Operator exec mode
Administrator exec mode
Global configuration mode
Interface
Terminal edit mode
Status after exit
Log out
Log out
Administrator exec mode
Global configuration mode
Global configuration mode
Prompt
xg>, xg#, xg(config)# , xg(config-if)# , xg(config-agg)# , xg(config-vlan)# , xg(config-line)#
Command syntax
Exit
Command type
Operation management commands
Example
Switch from the global configuration mode to the administrator exec mode using the "exit" command.
The prompt character will change to "xg#." xg#(config)# exit xg#
72/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.4.6 logout / quit
Function
Logs out and disconnects the terminal session.
Prompt
xg> or xg#
Command syntax
Logout
Command type
Operation management commands
Example
Log out and disconnect the terminal session. xg# logout
Connection closed by foreign host.
5.4.7 do
Function
Executes administrator exec mode commands from the global configuration mode.
Using this command saves the trouble of having to return to the administrator exec mode.
Prompt
xg(config)#
Command syntax do LINE
Parameter
LINE
Specifies the command line for the administrator exec mode to execute.
Command type
Operation management commands
Message
Can't execute this command.
Explanation
The specified command cannot be executed with the do command.
Solution
Execute the command in an appropriate mode without using the do command.
Example
Set "bridge aging-time" from the global configuration mode. And then, without returning to the administrator exec mode, check the setting status using the "show bridge" command. xg(config)# bridge aging-time 200 xg(config)# do show bridge
Switch Basic Information 2007/01/22-12:16:17
================================================================
Aging Time : 200 (sec)
Cut-through Switching : Enabled
Jumbo Frame Support : Enabled Max Frame Size: 9216 (byte)
Independent-vlan-learning: Enabled
DiffServ ToS : Disabled
================================================================
73/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.4.8 help
Function
Displays help on how to use the CLI.
Prompt
xg>, xg#, xg(config)# , xg(config-if)# , xg(config-agg)# , xg(config-vlan)# , xg(config-line)#
Command syntax
Help
Command type
Operation management commands
5.4.9 show account
Function
Displays information about the user.
Prompt
xg> or xg#
Command syntax show account
Command type
Operation management commands
Output form
xg# show account
Username Information 2007/10/04-14:33:42
=============================================================================
Username Class
-------------------------------- ---------- admin admin operator1 operator user0001 admin
=============================================================================
Username
Display the username.
Class
Display the class that the user can access to.
operator : The user can access operator class only. admin : The user can access both operator and administrator class.
Example
Display the user status. xg# show account
74/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.4.10 account
Function
Create a new user.
Use the no form to delete the specified user.
Prompt
xg#
Command syntax account USERNAME class { operator | admin }
no account USERNAME
Parameter
USERNAME
Specify a username with a length in the range of 2 to 16 characters, with an alphabet character at the beginning.
Follow these rules for specifying a username:
− Characters usable for the username
Alphabet ([a - z], [A - Z]), numerical characters ([0 - 9]), hyphen (-), underscore (_), and period (.)
− First character
Alphabet ([a - z], [A - Z]) class { operator | admin }
Specify the class that the user can access to.
− operator
The user can access operator class only.
− admin
The user can access both operator and administrator class.
Command type
Operation management commands
Default
admin (username) is admin class
Message
% The length of user name is invalid.
Explanation
The length of the username is invalid.
Solution
Specify the username between 2 and 16 characters.
% First character is invalid.
Explanation
The first character of the username is invalid.
Solution
Specify the first character of the username to be an alphabet.
% Invalid character is included.
Explanation
Invalid character is included in the username.
Solution
Specify characters usable for the username.
% USERNAME already exists.
Explanation
The user could not be added because specified username is already used.
Solution
Change the username or delete the user and execute the command again.
% cannot add user.
Explanation
The user could not be added.
Solution
Review the password and execute the command again.
% USERNAME does not exist.
Explanation
The user could not be deleted because it does not exist.
Solution
Review if the username exists.
% 4 users already exist.
Explanation
The maximum number of users was exceeded.
Solution
After deleting unnecessary users, execute the command again.
% The user name is reserved.
Explanation
Reserved username is specified.
Solution
Change the username and execute the command again.
75/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Note
Specify a password with a length in the range of 5 to 16 characters.
The maximum number of users that can register to this device is 4.
Example
Add user0001 as the username and specify operator class: xg# account user0001 class operator
Changing password for user0001
Enter the new password (minimum of 5, maximum of 16 characters)
Please use a combination of upper and lower case letters and numbers.
Enter new password:******
← Enter the password.
(The entered password is not displayed.)
Re-enter new password: ********
← Enter the new password again for confirmation
Password changed.
(The entered password is not displayed.)
5.4.11 password (Operator EXEC mode)
Function
Change the login password of logged in user to the device.
Prompt
xg>
Command syntax password
Command type
Operation management commands
Message
Bad password: too short.
Explanation
The password is too short.
Solution
Specify a password using five or more characters.
Bad password: too long.
Explanation
The password is too long.
Solution
Specify a password using 16 or less characters.
Note
This command (password command for Administrator exec mode) is executable only when the user can access operator class only (see account command for the details).
Specify a password with a length in the range of 5 to 16 characters.
Make a note of the changed password and retain it. Refer to Section 7.1.3, Restoring Factory Defaults for recovery of lost or forgotten passwords.
Login password information is not included in the configuration information. Therefore, even when the configuration information is downloaded to another device, the password information will not be displayed or transferred.
Example
operator1 that can access only operator class logged in the device and change own login password. xg> password
Changing password for operator1
Enter the new password (minimum of 5, maximum of 16 characters)
Please use a combination of upper and lower case letters and numbers.
Enter new password:
Re-enter new password:
Password changed.
76/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.4.12 password (Administrator EXEC mode)
Function
Change the login password of the device.
Prompt
xg#
Command syntax password
[USERNAME]
Parameter
USERNAME
Specify the username to change its login password. When USERNAME is omitted, the login password of own user is changed.
Command type
Configuration command
Message
Bad password: too short.
Explanation
The password is too short.
Solution
Specify a password using five or more characters.
Bad password: too long.
Explanation
The password is too long.
Solution
Specify a password using 16 or less characters.
Note
This command (password command for Global configuration mode) is executable only when the user can access both operator and administrator class (see account command for the details).
Specify a password with a length in the range of 5 to 16 characters.
Make a note of the changed password and retain it. Refer to Section 7.1.3, Restoring Factory Defaults for recovery of lost or forgotten passwords.
Login password information is not included in the configuration information. Therefore, even when the configuration information is downloaded to another device, the password information will not be displayed or transferred.
Example
Change the login password of the user that username is operator1. xg# password operator1
Changing password for operator1
Enter the new password (minimum of 5, maximum of 16 characters)
Please use a combination of upper and lower case letters and numbers.
Enter new password:
Re-enter new password:
Password changed.
77/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.4.13 reset
Function
Restarts the device.
Prompt
xg#
Command syntax reset
[ factory-default ]
Parameter
[ factory-default ]
When this parameter is specified, the contents of startup-config, log, and login password will be returned to the factory default.
Command type
Operation management commands
Note
When the system is restarted without having saved the running-config to startup-config, the information set in running-config will be lost.
When the device is restarted, the telnet and ssh sessions will be disconnected. Reconnect after restart of the system is complete.
Example
Restart the device using the "reset" command.
When the "reset" command is executed, the confirmation message is displayed. xg# reset
Do you restart system? (y/n) :
Confirmation message is displayed.
When "y" or "Y" is entered, the reboot process will be performed. When "n" or "N" is entered, the reboot process will be cancelled.
5.4.14 system shutdown
Function
Stops the device system and prepares it for power off.
After executing this command and the STATUS-LED goes out, turn off the power to the device.
Prompt
xg#
Command syntax system shutdown
Command type
Operation management commands
Note
When power to the device is turned off without executing the system shutdown command, the maintenance information will not be properly stored. Furthermore, if the power is turned off while data is being written to nonvolatile memory, it may be corrupted, and the system might not restart correctly on powerup.
When the system is shut down without saving running-config to startup-config, the information set in running-config will be lost.
Example
When the "system shutdown" command is executed, the confirmation message is displayed. xg# system shutdown
Do you shutdown system? (y/n) :
← Confirmation message is displayed.
When "y" or "Y" is entered, the system shutdown process will be performed. When "n" or "N" is entered, the system shutdown process will be canceled.
78/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.4.15 date
Function
Displays the date/time of the current system clock.
Prompt
xg> or xg#
Command syntax
Date
Command type
Operation management commands
Output form
The current date and time is displayed in the form of "year/month/date-hour:minutes:seconds." xg# date
2007/01/22-14:31:02
5.4.16 date set
Function
Changes the date/time of the current system clock.
Prompt
xg#
Command syntax date
set DATE-TIME
Parameter
DATE-TIME
Enter the date and time in the form of "MMDDhhmm[[CC]YY][.ss]."
− MM
Specify the month to set in the range of 1 to 12.
− DD
Specify the day to set in the range of 1 to 31.
− hh
Specify the hour to set in the range of 0 to 23.
− mm
Specify the minutes to set in the range of 0 to 59.
− [[CC]YY]
Specify the first two digits of the four digits of the year for CC. When it is omitted
20 will be specified.
Specify the last two digits of the four digits of the year for YY.
If CC and YY are both omitted, the year will not be changed.
− [.ss] (second <0 - 59>)
Specify the seconds to set in the range of 0 to 59.
Command type
Operation management commands
Message
% invalid date %1$.
Explanation
The specified parameter of the date and time is incorrect.
[[Inserted string]]%1$: specified date and time
Solution
Check that no mistakes have been made in the date and time parameter.
Example
Set the date and time of the system to 20:25:30, June 30, 2005. xg# date set 06302025.30
(Year omitted) or xg# date set 0630202505.30
(Year specified with the last two digits) or xg# date set 063020252005.30
(Year specified with four digits)
79/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.4.17 date timezone
Function
Sets the time zone of the device.
Use the no form to return to the default setup.
Prompt
xg#
Command syntax
Date timezone
gmt OFFSET
No date timezone
Parameter
gmt [ OFFSET ]
Specifies the time zone as the difference from GMT (Greenwich Mean Time).
The time difference from GMT is specified in the form of "+hhmm" (+ can be omitted) when setting forward from GMT.
It is specified in the form of "-hhmm" when setting backward from GMT.
− hh
Specifies the hour difference from GMT.
− mm
Specifies the minute difference from GMT.
It can be set in the range of -1200 to +1300.
Command type
Operation management commands
Default
0000
Message
% invalid input %1$.
Explanation
The specified parameter for the time difference is incorrect.
[[Inserted string]]%1$: specified time difference
Solution
Check that no mistakes have been made in the time difference parameter.
Note
The setting will be valid after restarting the system.
Use the "show system information" command to confirm the settings.
The setting will not be included in the configuration information. Therefore, even if the configuration information was restored by another device, the timezone setting will be invalid.
Example
Set the time zone to +9:00 (JST: Japan Standard Time) from GMT. xg# date timezone gmt +0900 or xg# date timezone gmt 0900
Then set the time zone to -1:30 from GMT. xg# date timezone gmt -0130
80/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.4.18 date summer-time
Function
Sets Daylight Saving Time.
Use the no form to return to the default setup.
Prompt
xg#
Command syntax date summer-time START_DAY[/TIME] END_DAY[/TIME] [OFFSET] no date summer-time
Parameter
START_DAY[/TIME]
Specifies the day/time to start Daylight Saving Time in any form of "Mm.w.d/hhmm," "Jn/hhmm," or "n/hhmm."
− Mm.w.d
Specifies the day to start Daylight Saving Time in m, w, and d.
Specify month for m (1 to 12), week for w (1 to 5), and the day of the week for d (0 to 6).
w = 1 means the first week where d exists, and w = 5 means the last week.
d = 0 means Sunday.
− Jn
Specifies the day to start Daylight Saving Time in day-of-year (Julian day). In leap years, February 29th is not counted. Specify a number in the range of 1 to 365 for n.
− n
Specifies the day to start Daylight Saving Time in day-of-year. In leap years, February
29th is counted. Specify a number in the range of 1 to 366 for n.
Specifies the following values, for the first day of each month in "Jn" specification and "n" specification.
Month/Day Jn specification specification
Common year Leap year
January 1st
February 1st
March 1st
April 1st
May 1st
June 1st
July 1st
J1
J32
J60
J91
J121
J152
J182
1
32
60
91
121
152
182
August 1st J213
September 1st J244
October 1st
November 1st
December 1st
J274
J305
J335
213
244
274
305
335
− hh
Specifies the hour to start Daylight Saving Time.
− mm
Specifies the minute to start Daylight Saving Time.
1
32
61
92
122
153
183
213
245
275
306
336
When hhmm is omitted, "0100" (an hour) is specified.
END_DAY[/TIME]
Specifies the day/time to end Daylight Saving Time. The description format is the same as
"START_DAY/TIME."
OFFSET
Specifies the time set forward during Daylight Saving Time in the form of "hhmm."
− hh
Specifies the hour set forward during Daylight Saving Time with a two-digit number.
It can be set in the range of 00 to 23.
− mm
Specifies the minute set forward during Daylight Saving Time with a two-digit number.
It can be set in the range of 00 to 59.
When this parameter is omitted, "0100" (an hour) is specified.
Command type
Operation management commands
Default
None
Message
% DATE '%1$' is invalid
Explanation
The specified date/time is incorrect.
[[Inserted string]]%1$: incorrect parameter value is displayed.
Solution
Correct the error in the parameter, and execute the command again.
81/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
% OFFSET '%1$' is invalid
Explanation
The specified OFFSET is incorrect.
[[Inserted string]]%2$: incorrect parameter value is displayed.
Solution
Correct the error in the parameter, and execute the command again.
% Parameter '%1$' is too long
Explanation
The parameter specified is too long.
[[Inserted string]]%1$: incorrect parameter value is displayed.
Solution
Correct the error in the parameter, and execute the command again.
% DATE '%1$' is too long
Explanation
The date specified is too long.
[[Inserted string]]%1$: incorrect parameter value is displayed.
Solution
Correct the error in the parameter, and execute the command again.
% Type of start-day and end-day is inconsistency
Explanation
Different formats are specified for start date and end date parameters of Daylight Saving
Time.
Solution
Make the formats of the start date and end date of Daylight Saving Time (Mm.w.d/ Jn/ n) consistent, and execute the command again.
Note
The setting will be valid after restarting the system.
Use the "show system information" command to confirm the settings.
The setting will not be included in the configuration information. Therefore, even if the configuration information was restored by another device, the timezone setting will be invalid.
Example
Set Daylight Saving Time period (from 2:00, Sunday, the first week in April, through to 02:00, Sunday, the fifth week in October, with a time difference of an hour). xg# date summer-time M4.1.0/0200 M10.5.0/0200 0100
82/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.4.19 ping
Function
Checks if communication with the specified host is possible by sending ICMP Echo Request packets to a specified host from the manage LAN interface and observing the reception of ICMP Echo Reply packets.
Prompt
xg> or xg#
Command syntax ping HOST [ count <1-100> ]
Parameter
HOST
Specifies the hostname or IP address to check. count <1-100>
Sets the count to transmit. 1 to 100. If omitted, 10 will be specified.
Press Ctrl + C to abort the ping process.
Command type
Operation management commands
Output form (when the host to check is working normally)
xg# ping white
PING white (192.168.1.1) from 192.168.1.2 : 56(84) bytes of data.
64 bytes from white (192.168.1.1): icmp_seq=1 ttl=64 time=0.780 ms
← There is a response.
64 bytes from white (192.168.1.1): icmp_seq=2 ttl=64 time=0.592 ms
← There is a response.
--- white ping statistics ---
← Displayed after aborting the process pressing Ctrl+ C.
5 packets transmitted, 5 received, 0% loss, time 4041ms rtt min/avg/max/mdev = 0.549/0.619/0.724/0.060 ms
Output form (when the host to check is in trouble)
xg# ping blue
PING blue (192.168.1.3) from 192.168.1.2 : 56(84) bytes of data.
← There is no response.
292 packets transmitted, 0 received, 100% loss, time 293516ms
← Displayed after aborting the process pressing Ctrl+ C.
Message
ping: unknown host %1$.
Explanation
The specified hostname is incorrect.
[[Inserted string]]%1$: specified hostname
Solution
Review the hostname, and execute the command again.
83/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.4.20 enable password
Function
Sets the password for the enable command.
Use the no form to disable the password protection.
Prompt
xg(config)#
Command syntax enable password no enable password
Parameter
password
Specifies the password to associate with the enable command.
After executing the command, entry of a password will be prompted. (Enter twice for confirmation.)
Specify a password with a length in the range of 5 to 16 characters.
Command type
Configuration command
Default
None
Note
The password will be encrypted and reflected in running-config.
The password will not be displayed by any means after executing the command. Make a note of the set password and retain it.
Example
Set the enable password from the global configuration mode using the "enable password" command.
Then, return to the administrator exec mode and execute "show running-config." The encoded password will be displayed. xg(config)# enable password
Enter password:
← Enter the password.
(The entered password is not displayed.)
Re-enter password:
← Enter the password again for confirmation.
(The entered password is not displayed.)
xg(config)# exit xg# show running-config enable encryption-password 4DUzjKbFg9.iU
← The password is encoded and output.
!
84/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.4.21 banner
Function
Sets the banner string to be displayed when logging in to the device.
Use the no form to delete the banner string.
Prompt
xg(config)#
Command syntax banner login LINE banner login default no banner
Parameter
login LINE
Sets a banner string. No need to enclose a parameter in quotes if it contains a blank space. login default
Returns the banner string to its default ("Product name firmware identification information").
Command type
Configuration command
Default
"Product name(XG2000, XG2000C or XG2000CR) firmware identification information"
The firmware identification information is the same information displayed in FirmWare[1] or FirmWare[2] of the "
show system information
Example
Set the banner string to "Welcome to XG2000." xg(config)# banner login Welcome to XG2000
85/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.4.22 ntp-server
Function
Synchronizes the system time to a specified NTP server’s time, using NTP (Network Time Protocol) Version3. Up to four NTP servers can be registered.
Use the no form to return the setting to its default.
Prompt
xg(config)#
Command syntax ntp-server host HOST ntp-server polling MINUTES ntp-server timeout SECONDS no ntp-server host HOST no ntp-server polling no ntp-server timeout
Parameter
host HOST
Specifies the hostname or IP address of an NTP server.
IP addresses that can be set are: 1.0.0.1 - 126.255.255.254, 128.0.0.1 - 191.255.255.254, and 192.0.0.1 - 223.255.255.254. polling MINUTES
Specifies the time interval for synchronizing the device time with an NTP server in minutes.
The value can be set in the range of 1 to 1440. timeout SECONDS
Specifies the response latency of an NTP server in seconds. The value can be set in the range of 1 to 4.
Command type
Configuration command
Default
host : None polling: 60 minutes timeout: 1 second
Message
% hostname can register up to 4.
Explanation
The number of hosts that can be set to an NTP server was exceeded.
Solution
After deleting unnecessary NTP servers, execute the command again.
% Cannot find %1$
Explanation
The specified host cannot be found.
[[Inserted string]]%1$: specified hostname
Solution
Check that the hostname is correct, or the hostname is registered.
% Hostname is too long
Explanation
The specified hostname is too long.
Solution
Check that the hostname is correct.
% Invalid IP-address.
Explanation
The specified format of the IP address or specified content is incorrect.
Solution
Specify the IP address in a correct format and execute the command again.
Note
Set the time zone and Daylight Saving Time to a correct value beforehand, and reboot the system. Then, NTP servers can be registered.
Example
Register an NTP server with IP address "192.168.1.1" and set the interval for time synchronization to 600 minutes. xg(config)# ntp-server host 192.168.1.1 xg(config)# ntp-server polling 600
86/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.5 Configuration File Operation Commands
This section explains the commands related to configuration files and file operations within volatile memory.
5.5.1 copy running-config startup-config
Function
Stores the configuration file (running-config) in volatile memory to the startup-config file in nonvolatile memory.
After changing running-config, use this command to use the same configuration file after restarting the system.
Prompt
xg#
Command syntax copy running-config startup-config
Command type
Operation management command
Note
When the system is restarted without saving the information of running-config into startup-config, the information set in running-config will be lost.
Be sure to upload the contents of the existing startup-config file to a TFTP server prior to saving running-config as the contents of startup-config will be overwritten.
Example
Store running-config in startup-config. Then, check the information in startup-config using the show command. xg# copy running-config startup-config xg# show startup-config
5.5.2 show running-config
Function
Displays the configuration information (running-config) currently operating in volatile memory.
Prompt
xg#
Command syntax show running-config
Command type
Operation management commands
Example
Display the contents of running-config. xg# show running-config
87/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.5.3 show running-config (redirect)
Function
Copies the configuration information (running-config) in the currently operating volatile memory to the volatile memory. Also, it can be copied directly to a file in the TFTP server using the "tftp" command.
Prompt
xg#
Command syntax show running-config > CONFIG-FILE show running-config | redirect CONFIG-FILE show running-config | tftp HOST REMOTE-FILE
Parameter
> CONFIG-FILE
Specifies the file name to copy in the volatile memory.
| redirect CONFIG-FILE
Specifies the file name to copy in the volatile memory. It means the same as "> CONFIG-FILE."
Follow the rules below in specifying file names:
− File names must start with alphabet ([a - z], [A - Z]).
− Characters usable for file names are: alphabet ([a - z], [A - Z]), numerical characters ([0 - 9]), underscore (_), and period (.)
| tftp
Redirects the copy to a file on the TFTP server.
HOST
Specifies the hostname of the TFTP server or IP address.
IP addresses that can be set are: 1.0.0.1 - 126.255.255.254, 128.0.0.1 - 191.255.255.254, and 192.0.0.1 - 223.255.255.254.
REMOTE-FILE
Specifies the file name to copy onto the TFTP server.
Command type
Operation management commands
Message
% tftp: %1$: Host name lookup failure
Explanation
The specified hostname does not exist.
[[Inserted string]]%1$: specified hostname
Solution
Check whether the specified hostname is correct.
% tftp: server says: %1$
Explanation
An error was received from the TFTP server.
[[Inserted string]]%1$: content of error message received from the TFTP server.
The content of message depends on the type of the TFTP server. For example, there is a message as below.
− File not found: There are no files in the TFTP server.
− Access violation: File permission error occurred in the TFTP server.
− Not allowed to overwrite existing files: The file in the TFTP server cannot be overwritten.
− Could not open requested file for reading: There are no files in the TFTP server.
− File already exists: There are files in the TFTP server.
− Unknown transfer ID: Process will be aborted in time out.
Solution
Take actions in accordance with the message received from the TFTP server.
% tftp: last timeout
Explanation
There is no response from the TFTP server. There is a possibility of network communication error with the management LAN, or the setting of time out of the TFTP server may be too short.
Solution
Check whether there is no problem in network connection with the TFTP server using the
"ping" command. If the problem persists, review the setting of time out of the TFTP server.
% Invalid IP-address.
Explanation
The specified format of the IP address or specified content is incorrect.
Solution
Specify the IP address in a correct format and execute it again.
88/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Note
When copied in the volatile memory, the information will be lost when the system is restarted.
If uploading is necessary, restart the system after storing the data in the TFTP server using the "tftp" command.
If there are no files in the TFTP server, or directories are specified, an error may occur. (it depends on the functionality of the TFTP server)
If timeout setting of the TFTP server is too short, an error may occur. (it depends on the functionality of the TFTP server)
Example
Copy the content of running-config to the file name "run_conf."
Then, upload the copied "run_conf" file with the file name "run_conf_20070122" in the TFTP server called "host1." xg# show running-config > run_conf xg# tftp put host1 run_conf run_conf_20070122
Copy the content of running-config directly to a file in the TFTP server "host1." xg# show running-config | tftp host1 run_conf run_conf_20070122
5.5.4 show startup-config
Function
Displays the configuration information (startup-config) stored in the nonvolatile memory of the device.
Prompt
xg#
Command syntax show startup-config
Command type
Operation management commands
Example
Display the content of startup-config. xg# show startup-config
89/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.5.5 show startup-config (redirect)
Function
Copies the startup-config file stored in nonvolatile memory to volatile memory. The configuration file can also be copied directly to a file on a TFTP server using the "tftp" command.
Prompt
xg#
Command syntax show startup-config > CONFIG-FILE show startup-config| redirect CONFIG-FILE show startup-config | tftp HOST REMOTE-FILE
Parameter
> CONFIG-FILE
Specifies the file name of the copy to be created in volatile memory.
| redirect CONFIG-FILE
Specifies the file name of the copy to be created in volatile memory. It means the same as
"> CONFIG-FILE."
Follow the rules below in specifying file names:
− File names must start with alphabet ([a - z], [A - Z]).
− Characters usable for file names are: alphabet ([a - z], [A - Z]), numerical characters ([0 - 9]), underscore (_), and period (.)
| tftp
Redirects the copy to a file on a TFTP server.
HOST
Specifies the hostname of the TFTP server or IP address.
IP addresses that can be set are: 1.0.0.1 - 126.255.255.254, 128.0.0.1 - 191.255.255.254, and 192.0.0.1 - 223.255.255.254.
REMOTE-FILE
Specifies the file name to copy onto the TFTP server.
Command type
Operation management commands
Message
% tftp: %1$: Host name lookup failure
Explanation
The specified hostname does not exist.
[[Inserted string]]%1$: specified hostname
Solution
Check whether the specified hostname is correct.
% tftp: server says: %1$
Explanation
An error was received from the TFTP server.
[[Inserted string]]%1$: content of error message received from the TFTP server.
The content of message depends on the type of TFTP server. For example, there is a message as below.
− File not found: There are no files on the TFTP server.
− Access violation: File permission error occurred in the TFTP server.
− Not allowed to overwrite existing files: The file in the TFTP server cannot be overwritten.
− Could not open requested file for reading: There are no files in the TFTP server.
− File already exists: There are files on the TFTP server.
− Unknown transfer ID: Process will be aborted in time out.
Solution
Take actions in accordance with the message(s) received from the TFTP server.
% tftp: last timeout
Explanation
There is no response from the TFTP server. A network communication error with the management LAN occurred, or the time out setting of the TFTP server may be too short.
Solution
Check the network connection with the TFTP server using the "ping" command. If the problem persists, review the time out setting of the TFTP server.
% Invalid IP-address.
Explanation
The specified format of the IP address or specified content is incorrect.
Solution
Specify the IP address in a correct format and execute the command again.
90/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Note
When copied into volatile memory, the file will be lost when the system is restarted.
If uploading is necessary, restart the system after storing the data on a TFTP server using the "tftp" command.
If there are no files on the TFTP server, or directories are not specified, an error may occur depending upon the functionality of the TFTP server.
If the timeout setting of the TFTP server is too short, an error may occur during transfer.
Example
Copy the content of running-config to a file named "run_conf."
Then, upload the copied "run_conf" file with the file name "run_conf_20070122" to the TFTP server called "host1." xg# show startup-config > start_conf xg# tftp put host1 start_conf start_conf_20070122
Copy the content of running-config directly to a file on the TFTP server "host1." xg# show startup-config | tftp host1 start_conf_20070122
91/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.5.6 copy startup-config
Function
Saves the configuration information stored in volatile memory to nonvolatile memory as startup-config. Also, startup-config can be loaded from a TFTP server using the "tftp" command.
After executing this command, it is necessary to restart the system using the "reset" command in order for the new startup-config to take effect.
Prompt
xg#
Command syntax copy local CONFIG-FILE startup-config copy tftp HOST REMOTE-FILE startup-config
Parameter
local CONFIG-FILE
Specifies the file name in volatile memory that data is copied.
Follow the rules below in specifying file names:
− File names must start with alphabet ([a - z], [A - Z]).
− Characters usable for file names are: alphabet ([a - z], [A - Z]), numerical characters ([0 - 9]), underscore (_), and period (.) tftp HOST
Transfers the file stored on the TFTP server.
Specifies the hostname of the TFTP server or IP address for HOST.
IP addresses that can be set are: 1.0.0.1 - 126.255.255.254, 128.0.0.1 - 191.255.255.254, and 192.0.0.1 - 223.255.255.254.
REMOTE-FILE
Specifies the file name stored on the TFTP server.
Command type
Operation management commands
Message
% Not found file: %1$
Explanation
The specified file cannot be found.
[[Inserted string]]%1$: specified file name
Solution
Check the file name, and execute the command again.
% Config-file(header) is invalid: %1$
Explanation
The specified file is not in a configuration file format.
[[Inserted string]]%1$: specified file name
Solution
Check the content of the file.
% Config-file(version/level) is invalid: %1$
Explanation
The configuration file firmware revision does not match the firmware revision installed on the device.
[[Inserted string]]%1$: specified file name
Solution
Check the content of the file.
% tftp: %1$: Host name lookup failure
Explanation
The specified hostname does not exist.
[[Inserted string]]%1$: specified hostname
Solution
Check whether the specified hostname is correct.
% tftp: server says: %1$
Explanation
An error was received from the TFTP server.
[[Inserted string]]%1$: content of error message received from the TFTP server.
The content of message depends on the type of TFTP server. For example:
− File not found: There are no files on the TFTP server.
− Access violation: File permission error occurred on the TFTP server.
− Not allowed to overwrite existing files: The file in the TFTP server cannot be overwritten.
− Could not open requested file for reading: There are no files in the TFTP server.
− File already exists: There are files in the TFTP server.
− Unknown transfer ID: Process will be aborted in time out.
Solution
Take actions in accordance with the message received from the TFTP server.
92/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
% tftp: write: No space left on device
Explanation
There is no free space for files to use as a work area on the device. Partial copies of the files being imported may remain in the device.
Solution
Delete the files on the device being processed for import, and unnecessary files using the "delete" command, and execute the command again.
% tftp: last timeout
Explanation
There is no response from the TFTP server. There is a possibility of network communication error with the management LAN, or the setting of time out of the TFTP server may be too short.
Solution
Check the network connection to the TFTP server using the "ping" command. If the problem persists, review the time out setting of the TFTP server.
% Invalid IP-address.
Explanation
The specified format of the IP address or specified content is incorrect.
Solution
Specify the IP address in a correct format and execute the command again.
Note
The startup-config uploaded using a new version of firmware may not be downloaded with an old version of firmware.
Example
Import the "start_conf_20070122" file stored on the TFTP server "host1" with the file name "start_conf."
Then copy the imported "start_conf" file to startup-config. xg# tftp get host1 start_conf_20070122 start_conf xg# copy local start_conf startup-config
Download the "start_conf_20070122" file stored on the TFTP server "host1 directly to startup-config. xg# copy tftp host1 start_conf_20070122 startup-config
93/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.5.7 dir/ls
Function
Lists the files in the volatile memory of the device.
Prompt
xg#
Command syntax dir ls
Command type
Operation management commands
Output form
xg# dir
Update-time File-size File-name
- 2007/01/22 19:23:03 913 system_info_20070122
- 2007/01/22 19:22:41 2,604 start_conf_20070122
- 2007/01/22 19:22:19 2,655 run_conf_20070122
unused: 14,639,104 bytes
Update-time
Displays the file update time.
File-size
Displays the file size (byte).
File-name
Displays the file name. unused
Displays the size of free memory.
Example
Copy running-config, startup-config and the system information to files in volatile memory, then list the files in volatile memory. xg# show running-config > run_conf_20070122 xg# show startup-config > start_conf_20070122 xg# show system information > system_info_20070122 xg# ls
Update-time File-size File-name
- 2007/01/22 19:23:03 913 system_info_20070122
- 2007/01/22 19:22:41 2,604 start_conf_20070122
- 2007/01/22 19:22:19 2,655 run_conf_20070122
unused: 14,639,104 bytes
94/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.5.8 delete
Function
Deletes the files in the volatile memory of the device.
Prompt
xg#
Command syntax delete FILE-NAMES
Parameter
FILE-NAMES
Specifies the name of the file to delete in the volatile memory.
Specify a generic designation with "*" (asterisk) for the file name, and files whose "*" part corresponds to the file name of arbitrary strings will be deleted.
Command type
Operation management commands
Message
% cannot remove `%1$': No such file or directory
Explanation
The specified file does not exist.
[[Inserted string]]%1$: specified file name
Solution
Check whether the specified file name is correct.
Example
Delete a file with the file name "run_conf_20070122". xg# delete run_conf_20070122
Specify a generic target for deletion with "run_conf_*". All files whose file name starts with "run_conf_" will be deleted. xg# delete run_conf_*
Specify "*" to delete all user files in the volatile memory. xg# delete *
95/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.5.9 rename
Function
Changes the file names in volatile memory.
Prompt
xg#
Command syntax rename FROM-NAME TO-NAME
Parameter
FROM-NAME
Specifies the file name to change.
TO-NAME
Specifies the new file name.
Follow the rules below in specifying file names:
− File names must start with alphabet ([a - z], [A - Z]).
− Characters usable for file names are: alphabet ([a - z], [A - Z]), numerical characters ([0 - 9]), underscore (_), and period (.)
Command type
Operation management commands
Message
% unable to rename `%1$': No such file or directory
Explanation
The specified file does not exist.
[[Inserted string]]%1$: specified file name
Solution
Check whether the specified file name is correct.
Example
Change a file with the file name "run_conf_20070122" to "run_conf." xg# rename run_conf_20070122 run_conf
96/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.5.10 tftp get
Function
Downloads files on the TFTP server into volatile memory.
Prompt
xg#
Command syntax tftp get HOST REMOTE-FILE [ LOCAL-FILE ]
Parameter
HOST
Specify the hostname of the TFTP server or IP address.
IP addresses that can be specified are: 1.0.0.1 - 126.255.255.254, 128.0.0.1 - 191.255.255.254, and 192.0.0.1 - 223.255.255.254.
REMOTE-FILE
Specifies the file name stored on the TFTP server.
[ LOCAL-FILE ]
Specifies the file name to save in volatile memory.
When this parameter is omitted, the "REMOTE-FILE" file name will be used.
Command type
Operation management commands
Message
% tftp: %1$: Host name lookup failure
Explanation
The specified hostname does not exist.
[[Inserted string]]%1$: specified hostname
Solution
Check whether the specified hostname is correct.
% tftp: server says: %1$
Explanation
An error was received from the TFTP server.
[[Inserted string]]%1$: content of error message received from the TFTP server.
The content of the message depends on the type of TFTP server. For example.
− File not found: There are no files in the TFTP server.
− Access violation: File permission error occurred in the TFTP server.
− Not allowed to overwrite existing files: The file in the TFTP server cannot be overwritten.
− Could not open requested file for reading: There are no files in the TFTP server.
− File already exists: There are files in the TFTP server.
− Unknown transfer ID: Process will be aborted in time out.
Solution
Take actions in accordance with the message received from the TFTP server.
% tftp: write: No space left on device
Explanation
There is not enough free space to store the files on the device. Portion of the files being imported may be present.
Solution
After deleting the files, processed for import, and unnecessary files using the "delete" command, execute the command again.
% tftp: last timeout
Explanation
There is no response from the TFTP server. A network communication error with the management LAN occurred, or the time out setting of the TFTP server may be too short.
Solution
Check the network connection with the TFTP server using the "ping" command. If the problem persists, review the time out setting of the TFTP server.
% local file: No such file or directory
Explanation
The specified file does not exist on the device.
Solution
Check the status of the file on the device.
% Invalid IP-address.
Explanation
The specified format of the IP address or specified content is incorrect.
Solution
Specify the IP address in a correct format and execute the command again.
Example
Copy the file "start_conf_20070122"on the TFTP server "host1", to the device using the file name "start_conf".
Then, check whether the file size of the file imported with the "tftp" command is consistent with the original using the dir/(ls) command. xg# tftp get host1 start_conf_20070122 start_conf xg# ls
Update-time File-size File-name
- 2007/01/22 19:22:41 2,604 start_conf
97/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.5.11 tftp put
Function
Uploads the files in volatile memory to the TFTP server.
Prompt
xg#
Command syntax tftp put HOST LOCAL-FILE [ REMOTE-FILE ]
Parameter
HOST
Specify the hostname of the TFTP server or IP address.
IP addresses that can be specified are: 1.0.0.1 - 126.255.255.254, 128.0.0.1 - 191.255.255.254, and 192.0.0.1 - 223.255.255.254.
LOCAL-FILE
Specifies a file name to upload.
[ REMOTE-FILE ]
Specifies the file name to use on the TFTP server.
When this parameter is omitted, the "LOCAL-FILE" file name will be used.
Command type
Operation management commands
Message
% tftp: %1$: Host name lookup failure
Explanation
The specified hostname does not exist.
[[Inserted string]]%1$: specified hostname
Solution
Check whether the specified hostname is correct.
% tftp: server says: %1$
Explanation
An error was received from the TFTP server.
[[Inserted string]]%1$: content of error message received from the TFTP server.
The content of the message depends on the type of TFTP server. For example.
− File not found: There are no files in the TFTP server.
− Access violation: File permission error occurred on the TFTP server.
− Not allowed to overwrite existing files: The file on the TFTP server cannot be overwritten.
− Could not open requested file for reading: There are no files in the TFTP server.
− File already exists: There are files on the TFTP server.
− Unknown transfer ID: Process will be aborted in time out.
Solution
Take actions in accordance with the message received from the TFTP server.
% tftp: last timeout
Explanation
There is no response from the TFTP server. A network communication error with the management LAN occurred, or the time out setting of the TFTP server may be too short.
Solution
Check the network connection with the TFTP server using the "ping" command. If the problem persists, review the time out setting of the TFTP server.
% local file: No such file or directory
Explanation
The specified file does not exist on the device.
[[Inserted string]]%1$: specified file name
Solution
Check the status of the file on the device.
% Invalid IP-address.
Explanation
The specified format of the IP address or specified content is incorrect.
Solution
Specify the IP address in a correct format and execute it again.
Note
If there are no specified files on the TFTP server, or incorrect directories are specified, an error may occur depending upon the functionality of the TFTP server.
When transferring a file with a large file size, if the time out is set short on the TFTP server, an error may occur.
In order to check whether the file was transferred successfully, check that the file size displayed by the "dir" or "ls" command is identical to the size of the file on the TFTP server.
Example
Copy the content of running-config to the file name "run_conf."
Then, upload the "run_conf" file to "run_conf_20070122" on the TFTP server called "host1." xg# show running-config > run_conf xg# tftp put host1 run_conf run_conf_20070122
98/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.6 Switch Basic Configuration Commands
This section explains configuration commands related to general operation of the switch.
5.6.1 clear bridge mac-address-table
Function
Deletes dynamically-learned MAC addresses from the MAC address table.
Prompt
xg#
Command syntax
#clear bridge mac-address-table dynamic { all | port <1-20> | agg-port <1-10> }
Parameter
dynamic { all | port <1-20> | agg-port <1-10> }
Specifies the port to delete the MAC address.
− all
Deletes MAC addresses dynamically-learned at every port.
− port <1-20>
Deletes MAC addresses dynamically-learned for a specific port.
− agg-port <1-10>
Deletes MAC addresses dynamically-learned for a specific aggregation group.
Command type
Operation management commands
Message
% Aggregation-port not bound to bridge
Explanation
The specified aggregation group was not created.
Solution
Check whether the specified aggregation group number is correct.
% Can't clear port which belongs to an aggregation port
Explanation
A port with link aggregation membership cannot be specified and deleted.
Solution
Specify an aggregation group and delete the MAC addresses.
Example
Delete all dynamically-learned MAC addresses. xg# clear bridge mac-address-table dynamic all
99/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.6.2 show bridge
Function
Displays the basic function configuration of the switch.
Prompt
xg> or xg#
Command syntax show bridge
Command type
Operation management commands
Output form
xg# show bridge
Switch Basic Information 2007/01/22-12:12:15
===============================================================================
Aging Time : {Disabled | <10-1756> } (sec)
Cut-through Switching : {Disabled | Enabled }
Jumbo Frame Support : {Disabled | Enabled Max Frame Size: 9216 (byte) }
Independent-vlan-learning : {Disabled | Enabled }
DiffServ ToS : {Disabled | Enabled }
===============================================================================
Aging Time
Displays the ageing time of the MAC address entries.
− Disabled
Aging is disabled.
− <10-1756> (sec)
Aging time (the time until a dynamically-learned MAC address expires) is displayed.
Cut-through Switching
The switching state is displayed.
− Disabled
The switching method is store-and-forward.
− Enabled
The switching method is cut-through.
Jumbo Frame Support
The jumbo frame support state is displayed.
− Disabled
Jumbo frames are not forwarded.
− Enabled Max Frame Size
Displays the maximum size of a jumbo frame that will be forwarded.
Independent-vlan-learning
The IVL (Independent Vlan Learning) is displayed.
− Disabled
The learning mode is SVL (Shared Vlan Learning).
− Enabled
The learning mode is IVL (Independent Vlan Learning).
DiffServ ToS
The DiffServ state based on ToS is displayed.
− Disabled
DiffServ is disabled.
− IPv4
DiffServ of IPv4 is enabled.
− IPv6
DiffServ of IPv6 is enabled.
Example
Display the basic function configuration of the switch. xg# show bridge
100/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.6.3 show bridge mac-address-table
Function
Displays the MAC address information registered in the MAC address table.
Prompt
xg> or xg#
Command syntax show bridge mac-address-table [ { static | dynamic | igmp-snooping
| port <1-20> | agg-port <1-10> | vlan <1-4094> } ]
Parameter
static
Displays only static MAC addresses. dynamic
Displays only dynamic MAC addresses.
igmp-snooping
Displays MAC addresses registered in IGMP snooping. port <1-20>
Specifies the port number of the switch to display. agg-port <1-10>
Specifies the aggregation group number of the switch to display.
Vlan <1-4094>
Specifies the vlan number of the switch to display.
When the parameters are omitted, all MAC addresses will be displayed.
Command type
Operation management commands
Output form
xg# show bridge mac-address-table
Mac Address Table Information 2007/01/22-12:12:15
Static Mac-address Table
------------------------------------------------------------------------
Mac-address Vlan-id Destination-port
-------------- -------- --------------------
0001.123a.4321 vlan-1 port 2
0002.123a.4321 vlan-1 port 4
0003.123a.4321 vlan-3 filter ef01.123a.4321 vlan-3 port 1 2 3 4 5 6 7 8
Dynamic Mac-address Table
----------------------------------------------------------------
Mac-address Vlan-id Destination-port
-------------- -------- --------------------
0004.123a.4321 vlan-1 port 4
IGMP snooping learning group Mac-address Table
----------------------------------------------------------------
Mac-address Vlan-id Destination-port
-------------- --------- -------------------------------------
(nothing)
================================================================
MAC addresses are sorted in the ascending order.
Mac-address
The destination MAC address is displayed.
Vlan-id
The associated VLAN ID is displayed.
When the learning mode of the MAC address table is SVL (Shared Vlan Learning), "-------" is displayed.
Destination-port
The associated destination port number is displayed.
− port <1-20>
The destination port number is shown. For multicast MAC addresses, multiple port numbers are displayed.
− filter
The MAC addresses are filtered.
Message
% IGMP snooping is not enabled.
Explanation
Since Global IGMP snooping is disabled, igmp-snooping cannot be specified.
Solution
After enabling IGMP snooping, specify igmp-snooping.
101/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Example
Display the content of all MAC address tables. xg# show bridge mac-address-table
Mac Address Table Information 2007/01/22-12:12:15
===================================================================
Static Mac-address Table
-------------------------------------------------------------------
Mac-address Vlan-id Destination-port
-------------- -------- --------------------
0001.123a.4321 vlan-1 port 2
0002.123a.4321 vlan-1 port 4
0003.123a.4321 vlan-3 filter ef01.123a.4321 vlan-3 port 1 2 3 4 5 6 7 8
Dynamic Mac-address Table
-------------------------------------------------------------------
Mac-address Vlan-id Destination-port
-------------- -------- --------------------
0004.123a.4321 vlan-1 port 4
IGMP snooping learning group Mac-address Table
-------------------------------------------------------------------
Mac-address Vlan-id Destination-port
-------------- --------- -----------------------------------------
(nothing)
===================================================================
By using the "| include" command, output lines which are matched with the parameter will be displayed. Display the information whose MAC address is 0002.123a.4321. xg# show bridge mac-address-table | include port 4
0002.123a.4321 vlan-1 port 4
View the MAC address information forwarded to port 4 among static MAC addresses. xg# show bridge mac-address-table static | include port 4
0002.123a.4321 vlan-1 port 4
0004.123a.4321 vlan-1 port 4
5.6.4 bridge forward-mode
Function
The device supports two types of frame forwarding, store-and-forward and cut-through.
Store-and-forward
After a full frame is received, an error check is performed before forwarding.
Cut-through
After reading the first 64 bytes of a received frame, forwarding is immediately performed.
Basically, FSC errors are not checked, allowing low latency forwarding.
Use the no form to return to store-and-forward.
Prompt
xg(config)#
Command syntax bridge forward-mode { cut-through | store-and-forward } no bridge forward-mode
Parameter
forward-mode { cut-through | store-and-forward }
Specifies the switching method.
− cut-through
Specifies Cut-through forwarding.
− store-and-forward
Specifies store-and-forward forwarding.
Command type
Configuration command
Default
cut-through
Note
The no form command does not return the forwarding mode to its default setting.
Example
Set the switching method to cut-through. xg(config)# bridge forward-mode cut-through
102/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.6.5 bridge jumbo-frame
Function
Sets the maximum frame size of jumbo frames. The maximum frame size that can be forwarded is 16128 byte.
Use the no form to disable jumbo frame.
Prompt
xg(config)#
Command syntax bridge jumbo-frame [ { 9216 | 12288 | 15360 | 16128 } ] no bridge jumbo-frame
Parameter
jumbo-frame [ { 9216 | 12288 | 15360 | 16128 } ]
Specifies the maximum frame size of the jumbo frame.
− 9216
Sets the permitted jumbo frame size to 9216 byte.
− 12288
Sets the permitted jumbo frame size to 12288 byte.
− 15360
Sets the permitted jumbo frame size to 15360 byte.
− 16128
Sets the permitted jumbo frame size to 16128 byte.
When this parameter is omitted, 9216 is specified.
Command type
Configuration command
Default
9216
Note
Forwardable frame sizes
The following shows the forwardable frame size when jumbo frame forwarding is disabled.
Frame status Forwardable frame size
User VLAN + VLAN-tagged 1526 bytes
When jumbo frame forwarding is permitted, the forwardable frame size will include the additional bytes required for VLAN tagged and user VLAN tagged frames.
Example
Set jumbo frame to permit up to 9216 byte frames. xg(config)# bridge jumbo-frame 9216
103/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.6.6 bridge learn-mode
Function
Sets the MAC address table learning mode.
The device supports two learning modes: SVL (Shared Vlan Learning) and IVL (Independent VLAN Learning).
SVL (Shared VLAN Learning)
Regardless of the VLAN of frame ownership, it is learned as a MAC address entry (mapping of MAC address to port) common to every VLAN.
IVL (Independent VLAN Learning)
A MAC address entry (mapping of MAC address for port) is learned for each VLAN.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax bridge learn-mode { ivl | svl } no bridge learn-mode
Parameter
learn-mode { ivl | svl }
Specifies the MAC address table learning mode.
− ivl
Specifies IVL (Independent Vlan Learning).
− svl
Specifies SVL (Shared Vlan Learning).
Command type
Configuration command
Default
svl
Note
When changing from SVL to IVL, MAC addresses registered statically in SVL will be registered in VLAN ID 1. Also, when changing from IVL to SVL, MAC addresses registered statically in IVL will be all cleared, except for the ones registered in VLAN ID 1.
Example
This example sets the MAC address table learning mode to IVL (Independent VLAN Learning). xg(config)# bridge learn-mode ivl
104/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.6.7 bridge mac-address-table
Function
By registering static MAC addresses to the MAC address table, frames with specific destination MAC addresses can be forwarded to a specified port.
When a unicast static MAC address is registered, dynamic MAC addresses will not be learned, even when frames sent from the same MAC address are received from a different port. Also, by registering multicast static MAC addresses, frames to be sent to specific multicast nodes can be assigned so that they will be forwarded only to the port specified. In this case, set the multicast forwarding mode to "forward-unregistered-mac" or "filter-unregistered-mac" using the "multicast-forwarding" command.
Use the no form to delete registered static MAC addresses.
Prompt
xg(config)#
Command syntax bridge mac-address-table static MAC [ vlan <1-4094> ] [ port <1-20> [ <1-20> ] ]
[ agg-port <1-10> [ <1-10> ] ] no bridge mac-address-table static MAC [ vlan <1-4094> ]
Parameter
static MAC
Specifies static MAC addresses. When a frame with this destination address is received, it will be forwarded to the port specified.
The MAC address format is "HHHH.HHHH.HHHH," a 12-digit hexadecimal number with a period (.) inserted between every four digits.
A unicast MAC address can register the information for only one port in the MAC address table. (As for IVL, one port per VLAN) Therefore, if the same unicast MAC address is already assigned to a different port, the entry will be replaced if the same MAC address and different port are specified in a subsequent “mac-address-table static” command.
A multicast MAC address can registered for multiple ports in the MAC address table. If the same multicast MAC address is already set to a port, subsequent assignments of the MAC address to additional ports will be appended to the address table.
A broadcast address (FFFF.FFFF.FFFF) can be registered to multiple ports. However, the entry will be replaced with subsequent commands registering non-broadcast addresses to the ports previously assigned.
The following reserved multicast addresses, prescribed in IEEE802.1D, cannot be registered.
− In the range of 0180.C200.0000 - 0180.C200.0010
− In the range of 0180.C200.0020 - 0180.C200.002F vlan <1-4094>
Specifies a VLAN to register with the MAC address. Specify a VLAN in the range of 1 to 4094.
This parameter is valid only when the learning mode of the MAC address table is IVL (Independent
Vlan Learning). For SVL (Shared Vlan Learning), this parameter is not necessary. port <1-20> [ <1-20> ]
Specifies the port number for the forwarded frame. This parameter is specified in the range of 1 to the maximum number of ports (=20).
Additionally, when static multicast MAC addresses are registered (including broadcast addresses), multiple ports can be specified by separating the port numbers with a " " (space). agg-port <1-10> [ <1-10> ]
Specifies the aggregation group number for the forwarded frame. This parameter is specified in the range of 1 to 10.
Additionally, when static multicast MAC addresses are registered (including broadcast addresses), multiple aggregation groups can be specified by separating the aggregation group numbers with a " " (space).
Command type
Configuration command
Default
Only broadcast address (FFFF.FFFF.FFFF) is registered.
Message
% Unable to translate mac address %1$
Explanation
The specified format of the MAC address is incorrect.
[[Inserted string]]%1$: specified MAC address
Solution
After reviewing the specified format of the MAC address, execute the command again.
% Can't set vlan in case of shared-vlan-learning.
Explanation
When the bridge learn-mode is SVL, VLANs cannot be specified.
Solution
Omit the vlan parameter, and execute the command again.
% Vlan id is not found. vid=%1$
Explanation
The specified VLAN is not created.
105/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
[[Inserted string]]%1$: VLAN ID
Solution
Review the vlan specified then execute the command again.
% Port is not vlan member. port %1$ vid=%2$
Explanation
The port is not a member of the specified VLAN.
[[Inserted string]]%1$: port number
[[Inserted string]]%2$: VLAN ID
Solution
Assign the specified port to the intended vlan then execute the command again.
% Aggregation port is not vlan member. agg-port %1$ vid=%2$
Explanation
The specified aggregation group is not a VLAN member.
[[Inserted string]]%1$: port number
[[Inserted string]]%2$: VLAN ID
Solution
Assign the specified aggregation group to the intended vlan then execute the command again.
% Can't set mac-address-table. %1$ vid=%2$
Explanation
The maximum number of table entries was exceeded.
[[Inserted string]]%1$: specified port number
[[Inserted string]]%2$: VLAN ID
Solution
After deleting unnecessary MAC addresses, execute the command again.
% In case of a unicast address, can set only one port.
Explanation
For a unicast MAC address, only one port can be specified.
Solution
After the specified port information then execute the command again.
% port is a member of aggregation group. port %1$
Explanation
A port with link aggregation membership cannot be specified.
[[Inserted string]]%1$: port number
Solution
Specify an aggregation group then execute the command again.
% Aggregation port is not found. agg-port %1$
Explanation
The specified aggregation group does not exist.
[[Inserted string]]%1$: specified aggregation group number
Solution
Review the specified aggregation group number then execute the command again.
% MAC address is reserved by IEEE802.1D %s.
Explanation
MAC addresses reserved under the IEEE802.1D cannot be specified.
[[Inserted string]]%1$: MAC address
Solution
Review the specified MAC address.
% Can't remove mac-address from static forwarding-table.
Explanation
The specified MAC address cannot be deleted.
Solution
Review the specified VLAN or MAC address.
Note
The maximum number of unicast MAC addresses or multicast MAC addresses that can be statically registered to the device are 128 addresses for each types of address. Additionally, since MAC addresses are managed with a hash table, a message saying an address cannot be registered may be displayed before reaching the maximum number.
Example
The following example shows how to add a static MAC address 0001.2300.4567. xg(config)# bridge mac-address-table static 0001.2300.4567 port 2
Register a static MAC address c1b1.123a.4321 belonging to VLAN3. When a frame with this MAC address as its destination is received from VLAN3, it will be forwarded to the specified port. xg(config)# bridge mac-address-table static c1b1.123a.4321 vlan 3 port 4
All registered MAC address information can be checked using the show mac address-table command. Combine with the "| include" command, information for a specific MAC address can be output. xg# show bridge mac-address-table static
Static Mac-address Table
--------------------------------------------------------------
Mac-address Vlan-id Destination-port
-------------- --------- -------------------------------------
0001.123a.4321 vlan-1 port 2
0002.123a.4321 vlan-1 port 4
0100.5e00.1001 vlan-1 port 1 2 3 4 5 6 7 8 ffff.ffff.ffff vlan-1 port 1 2 3 4 5 6 7 8 9 10 11 12
0003.123a.4321 vlan-2 port 4 ffff.ffff.ffff vlan-2 port 1 2 3 4 5 6 7 8 9 10 11 12 xg# show bridge mac-address-table static | include 0001.123a.4321
0001.123a.4321 vlan-1 port 2
106/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.6.8 bridge mac-address-table filter
Function
By registering a MAC address to filter, a frame with a specific destination MAC address will be discarded.
When filtering of a MAC address is specified, dynamic learning of the MAC address will not be performed, even when frames sent from the same MAC address are received on a different port.
Use the no form to delete the MAC address to filter.
Prompt
xg(config)#
Command syntax bridge mac-address-table static MAC [ vlan <1-4094> ] filter no bridge mac-address-table static MAC [ vlan <1-4094> ]
Parameter
static MAC
Specifies the destination MAC address to filter.
The MAC address format is "HHHH.HHHH.HHHH," a 12-digit hexadecimal number, with a period
(.) inserted between every four digits. vlan <1-4094>
Specifies the VLAN to filter. Specify a VLAN in the range of 1 to 4094.
This parameter is valid only when the learning mode of the MAC address table is IVL (Independent
Vlan Learning). For SVL (Shared Vlan Learning), this parameter is not necessary.
Command type
Configuration command
Default
None
Message
% Unable to translate mac address %1$
Explanation
The specified format of the MAC address is incorrect. Broadcast addresses cannot be registered.
[[Inserted string]]%1$: specified MAC address
Solution
After edit the specified format of the MAC address, execute the command again.
% Can't set vlan in case of shared-vlan-learning.
Explanation
When bridge learn-mode is SVL, a VLAN cannot be specified.
Solution
Omit the specified vlan and parameter then execute the command again.
% Vlan id is not found. vid=%1$
Explanation
The specified VLAN does not exist.
[[Inserted string]]%1$: VLAN ID
Solution
Review the specified vlan then execute the command again.
% port is a member of aggregation group. port %1$
Explanation
A port with membership in a link aggregation group cannot be specified.
[[Inserted string]]%1$: port number
Solution
Specify an aggregation group then execute the command again.
% Aggregation port is not found. agg-port %1$
Explanation
The specified aggregation group does not exist.
[[Inserted string]]%1$: specified aggregation group number
Solution
Review the specified aggregation group number then execute the command again.
% MAC address is reserved by IEEE802.1D %s.
Explanation
MAC addresses reserved under the IEEE802.1D cannot be specified.
[[Inserted string]]%1$: MAC address
Solution
Review the specified MAC address.
% Can't set mac-address-table. vid=%1$
Explanation
The maximum number of table entries was exceeded.
[[Inserted string]]%1$: VLAN ID
Solution
After deleting unnecessary MAC addresses, execute the command again.
Note
The maximum number of unicast MAC addresses or multicast MAC addresses that can be statically registered to the device are 128 addresses for each type of address including filtered addresses also included in these. Additionally, since MAC addresses are managed with a hash table, a message saying an address cannot be registered may be displayed before reaching the maximum number.
Example
The following example filters MAC address 0001.2300.4567.
107/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide xg(config)# bridge mac-address-table static 0001.2300.4567 filter
Filter MAC address c1b1.123a.4321 belonging to VLAN3. Frames, with this MAC address destination are discarded. xg(config)# bridge mac-address-table static c1b1.123a.4321 vlan 3 filter
Using the show mac address-table command, filtered MAC address and all registered MAC address information will be displayed. Combined with the "| include" command, information for filtered MAC addresses can be output. xg# show bridge mac-address-table static
Mac Address Table Information 2005/06/23-07:18:06
==================================================================
Static Mac-address Table
----------------------------------------------------------------------------
---
Mac-address Type Vlan-id Destination-port
-------------- ------- -------- --------------------
0001.123a.4321 static vlan-1 port 2
0002.123a.4321 static vlan-1 port 4
0003.123a.4321 static vlan-3 filter ef01.123a.4321 static vlan-3 port 1 2 3 4 5 6 7 8
================================================================== xg# show bridge mac-address-table static | include filter
0003.123a.4321 static vlan-3 filter
5.6.9 bridge aging-time
Function
Sets the aging time (the remaining time before the MAC address dynamically learned in the MAC address table expires and then is deleted). The aging time is applied to all VLANs.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax bridge aging-time { 0 | <10-1756> } no bridge aging-time
Parameter
aging-time 0
Dynamically learned MAC addresses will not expire, and will be permanently retained in the
MAC address table. aging-time <10-1756>
Specifies the aging time for a dynamically learned MAC address in seconds. It can be set to a value in the range of 10 to 1756 (seconds).
Command type
Configuration command
Default
300 seconds
Note
The maximum error between the value of aging time and the time a MAC address actually expires in the device is
±1.7 seconds.
Example
Set the aging time to 400 seconds. xg(config)# bridge aging-time 400
Disable the aging time. xg(config)# bridge aging-time 0
108/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.7 Link Aggregation Configuration Commands
This section explains the commands associated with link aggregation.
5.7.1 show link-aggregation
Function
Displays the state of an aggregation group.
Prompt
xg> or xg#
Command syntax show link-aggregation [ agg-port <1-10> ]
Parameter
agg-port <1-10>
Specifies the aggregation group number. The value can be set in the range of 1 to 10.
When this parameter is omitted, the state of all aggregation groups will be displayed.
Command type
Operation management commands
Output form (in case of static link aggregation)
xg# show link-aggregation
Link Aggregation Information 2007/01/22-14:30:35
===============================================================================
System Priority : 32768
System ID : 0080.17c2.2144
-------------------------------------------------------------------------------
[agg-port 1]
Master port : port <1-20>
Management packet send port : port <1-20>
Mac address : 0080.17c2.2144
Protocol : None
Distribution algorithm : { Destination address | Source address
| Destination address & Source address
| Vlan | IP Hash }
{ Destination IP | Source IP
| Destination port | Source port }
Distribution parameter : <0-3>
The minimum number of ports : 1
[port 1]
Port Status : {Active | Inactive }
[port 2]
Port Status : {Active | Inactive }
-------------------------------------------------------------------------------
[agg-port 2]
================================================================================
Link aggregation group common information
Link aggregation information related to the switch in general will be displayed.
System Priority
The system priority used by LACP is displayed.
System ID
The identification information used by LACP is displayed.
The state of each aggregation group will be displayed.
[agg-port 1]
Indicates the aggregation group number being displayed.
Master port
Displays the master port number of the aggregation group.
Of the ports belonging to a link aggregation group, the one with the smallest port number will be the master port.
Management packet send port
The port number, transmitting the control protocol between switches such as BPDU and IGMP, are displayed.
Normally, of the ports belonging to an aggregation group, the one with the smallest port number among the ports in a link up state will be the management packet send port.
Mac address
Displays the MAC address of the aggregation group. This MAC address will be the same value as that of the master port.
109/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Protocol
The control protocol utilized by the link aggregation group is displayed.
− None
A static link aggregation group.
− LACP - Active
Uses LACP as the control protocol for link aggregation in Active mode.
− LACP - Passive
Uses LACP as the control protocol for link aggregation in Passive mode.
Distribution algorithm
Displays the distribution method for frame forwarding across the aggregated ports.
− Destination address
This is a distribution method based on the destination MAC address of a frame.
− Source address
This is a distribution method based on the transmitted frame MAC address.
− Destination address & Source address
This is a distribution method based on the information of the destination MAC address of a frame and the transmitted frame MAC address.
− Vlan
This is a distribution method based on the VLAN membership of a frame.
− IP Hash
This is a distribution method based on the following frame information.
− Destination IP
Frames are distributed based on destination IP address.
− Source IP
Frames are distributed based on source IP address.
− Destination port
Frames are distributed based on destination TCP/UDP port.
− Source port
Frames are distributed based on source TCP/UDP port.
Distribution parameter
Displays the parameter used to calculate the distribution of frames.
The minimum number of ports
Displays the port minimum number of ports that must be in a link up required to maintain a link up state for the aggregation group.
Static link aggregation specific information
The state of each port belonging to a static link aggregation group is then listed.
[port 1]
Indicates the port number being displayed.
Port Status
The status of the port is displayed.
− Active
The port is usable.
− Inactive
The port is not usable.
110/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Output form (in case of LACP link aggregation)
xg# show link-aggregation
Link Aggregation Information 2005/04/24-16:16:36
===============================================================================
System Priority : 32768
System ID : 0080.17c2.05e2
-------------------------------------------------------------------------------
[agg-port 1]
Master port : port <1-20>
Management packet send port : port <1-20>
Mac address : 0080.17c2.2144
Protocol : { LACP - Active | LACP - Passive }
Distribution algorithm : { Destination address | Source address
| Destination address & Source address
| Vlan | IP Hash }
{ Destination IP | Source IP
| Destination port | Source port }
The minimum number of ports : 1
System Key : 1
Partner System Priority : 32768
System ID : 0080.17c2.05e2
Key : 2
[port 1]
Port Status : {Active | Inactive }
Port Priority : 32768
Synchro State : { Sync | No Sync }
Receive State : { Invalid | Initialize | Port Disabled | LACP Disabled| Expired
| Defaulted| Current}
Periodic Tx State : { Invalid | No Periodic | Fast Periodic | Slow Periodic }
Partner Port Priority : 32768
Partner Port Number : 10011
Partner Synchro State : { Sync | No Sync }
[port 2]
Port Status : { Active | Inactive }
Port Priority : 32768
Synchro State : { Sync | No Sync }
Receive State : { Invalid | Initialize | Port Disabled | LACP Disabled | Expired
| Defaulted| Current}
Periodic Tx State : { No Periodic | Fast Periodic | Slow Periodic }
Partner Port Priority : 32768
Partner Port Number : 11
Partner Synchro State : { Sync | No Sync }
[agg-port 2]
===============================================================================
Link aggregation common information
Link aggregation information related to the switch in general will be displayed. The display content is the same as the case of a static link aggregation group.
LACP Link aggregation specific information
Items common to each aggregation group that will be displayed.
System Key
The system key used by LACP is displayed.
Partner
The LACP destination device connection type is displayed.
− System Priority
LACP system priority for the destination device connection is displayed.
− System ID
LACP system identification for the destination device connection is displayed.
− Key
The LACP system key for the destination device connection is displayed.
The state of each port belonging to an LACP link aggregation group is then listed.
[port 1]
Indicates the port number being displayed.
Port Priority
The status of the port is displayed.
− Active
The port is usable.
− Inactive
The port is not usable.
Synchro State
The synchronization status of the port is displayed.
− Sync
The link state of LACP with the destination device connection is in a synchronized state.
− No Sync
The link state of LACP with the destination device connection is not in a synchronized state.
111/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Receive State
Displays the reception status of LACP protocol.
− Invalid
The LACP port destination device connection is in trouble.
− Initialize
The LACP port destination device connection is in initializing.
− Port Disabled
The LACP port of the destination device connection is disabled.
− LACP Disabled
LACP at the connection destination device is disabled.
− Expired
LACP information with for destination device connection expired.
− Defaulted
The LACP port of the destination device is about to be connected.
− Current
The LACP port of the destination device is an LACP connected state.
Periodic Tx State
The state of the LACP transmit interval control frame is displayed.
− No Periodic
An LACP control frame will not be sent.
− Fast Periodic
LACP control frames are sent at short intervals.
− Slow Periodic
LACP control frames are sent at long intervals.
Partner Port Priority
The port priority value of the connection's destination device is displayed.
Partner Port Number
The port number of the connection's destination device is displayed.
Partner Synchro State
The port synchronization status of the connection destination device is displayed.
− Sync
The LACP link state is synchronized.
− No Sync
The LACP link state is not synchronized.
Example
Display the state of all aggregation groups. xg> show link-aggregation
112/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.7.2 link-aggregation
Function
Link aggregation is a function wherein multiple ports within a switch act as one logical link (aggregated group). This command is used to set up a link aggregation group.
There are two types of link aggregation: static link and LACP.
Static link aggregation
An aggregation group is created statically.
LACP link aggregation
An aggregation group in compliance with IEEE802.3ad LACP (Link Aggregation Control Protocol) is created. LACP is a control protocol among switches for dynamically assembling an aggregation group.
Use the no form to delete an aggregation group.
Prompt
xg(config)#
Command syntax link-aggregation agg-port <1-10> [protocol {none | lacp}] [lacp-mode {active | passive}]
[load-balance {dst-mac | src-mac | dst-src-mac | vlan | ip-hash}]
[ distribution-parameter <0-3> ]
[minimum-port <1-10>] port <1-20> <1-20> [ <1-20> ] no link-aggregation agg-port <1-10>
Parameter
agg-port <1-10>
Specifies the aggregation group number to create. Specify a number in the range of 1 to 10. protocol {none | lacp}
Specifies the protocol type of the link aggregation.
− none
A static link aggregation group.
− lacp
A link aggregation group using IEEE802.3ad LACP as the control protocol between switches.
When this parameter is omitted, "none" is assumed. lacp-mode {active | passive}
Specifies the operational mode of LACP negotiation.
− active
Negotiation of LACP is started from the device. Also, since the active mode can receive
LACP packets, a connection between two LACP active mode enabled switches is possible.
− passive
The device will be in the passive mode of the LACP protocol. The switch responds to
LACP packets, but will not start negotiation.
This parameter can be specified only when "lacp" is specified as the "protocol" parameter.
When this parameter is omitted, "active" is assumed. load-balance { dst-mac | src-mac | dst-src-mac | vlan | ip-hash }
Specifies the frame distribution method for each port in the aggregation group
− dst-mac
Determines the forwarding destination port, based on the destination MAC address of the frames.
− src-mac
Determines the forwarding destination port, based on the source MAC address.
− dst-src-mac
Determines the forwarding destination port, based on the destination MAC address of a frame and the source MAC address.
− vlan
Determines the forwarding destination port, based on VLAN membership.
− Ip-hash
Determines the forwarding destination port, based on the IP hash information.
When this parameter is omitted, "dst-mac" is assumed.
If there are not many MAC addresses to be distributed across an aggregation group, the distribution among the destination ports tends to become biased. To reduce such bias, use a distribution method that uses more MAC addresses.
If a server is connected to an aggregation group and a client is connected to a different port, it is recommended that either "src-mac" or "dst-src-mac" be used.
If the load balancing of frame forwarding is questioned, the traffic state of each port can be checked by using the "monitor traffic-bytes" or the "monitor traffic-counts" commands.
113/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide distribution-parameter <0-3>
Specifies a parameter used in calculating of frame distribution method.
When this parameter is omitted, "0" is assumed.
Under certain circumstances, load balance bias may not be resolved, when the distribution method is changed. By changing the distribution parameter value, the bias can be minimized.
However, this value affects the distribution patterns only. Changing the value does not guarantee resolution of frame distribution bias. minimum-port <1-10>
Specifies the minimum number of ports in a link up state required to maintain the link up state of the aggregation group.
When the number of ports in a link up state within an aggregation group is less than the minimum number of ports specified, the aggregation group changes to a link down state.
When this parameter is omitted, 1 is assumed. port <1-20> <1-20> [ <1-20> ]
Assigns port numbers to an aggregation group. Separate each port number with a " " (space).
Specify two or more port numbers.
Command type
Configuration command
Default
None
Message
% agg-port %1$ already exists
Explanation
An aggregation group with the same number already exists.
[[Inserted string]]%1$: specified aggregation group number
Solution
Review the specified aggregation group number, and execute the command again.
% protocol is not LACP
Explanation
Although the protocol specified was not lacp, lacp-mode was specified.
Solution
When the protocol is not lacp, do not specify lacp-mode.
% The maximum number of member ports is 10
Explanation
The number of specified ports was more than 10.
Solution
Set the number of ports to 10 or less.
% port %1$ is already member of aggregation group
Explanation
The specified port already belongs to another aggregation group.
[[Inserted string]]%1$: specified port number
Solution
Specify a port not belonging to any aggregation groups.
% Same port number is found %1$
Explanation
The duplicate port numbers were specified.
[[Inserted string]]%1$: port number duplicated
Solution
Edit the port numbers then execute the command again.
% Minimum-port is too large %1$
Explanation
The number of ports specified in minimum-port surpasses the number of ports constituting the aggregation group.
[[Inserted string]]%1$: specified number of ports
Solution
Specify a minimum-port value equal to or less than the total number of ports within the aggregation group. Then execute the command again.
% port %1$ is membership of uplink-domain %2$.
Explanation
The specified port already belongs to an uplink domain.
[[Inserted string]]%1$: specified port number
[[Inserted string]]%2$: uplink domain number
Solution
Specify a port not belonging to any uplink domains. Or remove the port from an uplink domain.
114/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Note
Among the ports belonging to an aggregation group, the port with the smallest port number will be the master port.
Ports added to an aggregation group immediately after a link aggregation group is initially created will inherit the same settings as that of the master port. The values different from the master port are as follows:
− "link-pass-through" settings for each appended port will be cleared.
− The MAC address table entries for each appended port will be cleared.
− The values for "spanning-tree port-path-cost" will change in accordance with the number of member ports.
When changing the setting of an aggregation group already created, if the following conditions are met, the aggregation group will change temporarily to a link down state and then to link up again and the port setting becomes default.
− When the master port is deleted.
− When the master port is changed.
− When protocol or lacp-mode parameters are changed.
A port belonging to an uplink domain cannot be assigned to a link aggregation group.
Example
Set up a static link aggregation group with ports 1 and 2 as aggregation group number 1.
Then move to the interface edit mode of the aggregation group, and assign a VLAN ID of 2. xg(config)# link-aggregation agg-port 1 protocol none port 1 2 xg(config)# interface agg-port 1 xg(config-agg)# port-vlan-id vlan 2
Set up an LACP link aggregation group of LACP with ports 3, 4, and 5 as aggregation group number 2.
− Port Members : 3, 4, 5
− LACP mode : active
− Distribution method : distribution by destination MAC
− Link up condition minimum number of ports: 2 xg(config)# link-aggregation agg-port 2 protocol lacp lacp-mode active load-balance dst-mac minimum-port 2 port 3 4 5
5.7.3 lacp system-priority
Function
Sets the system priority used by LACP.
The system priority is used as information for identifying switches via LACP. Typically, it is not necessary to change its value from the default.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax lacp system-priority <1-65535> no lacp system-priority
Parameter
system-priority <1-65535>
Assigns the LACP system priority value in the range of 1 to 65535.
Command type
Configuration command
Default
32768
Example
Set the LACP system priority to 10000. xg(config)# lacp system-priority 10000
115/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.7.4 lacp port-priority
Function
Sets the priority of LACP ports.
The LACP port priority is used as information for identifying ports via LACP. Typically, it is not necessary to change its value from the default.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax lacp port-priority port <1-20> priority <1-65535> no lacp port-priority port <1-20>
Parameter
port <1-20>
Specifies a port number in the range of 1 to 20 to assign an LACP port priority. priority <1-65535>
Specifies an LACP port priority value in the range of 1 to 65535.
Command type
Configuration command
Default
32768
Example
Set LACP port priority to 10000 for Port 2. xg(config)# lacp port-priority port 2 priority 10000
5.7.5 link-aggregation load-balance ip-hash-selection
Function
Set the parameter(s) used by the link aggregation IP hash frame distribution function.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax link-aggregation load-balance ip-hash-selection {src-ip | dst-ip | src-port | dst-port} no link-aggregation load-balance ip-hash-selection
Parameter
ip-hash-selection {src-ip | dst-ip | src-port | dst-port}
Specifies the IP hash parameter used for frame distribution function within a link aggregation group. These parameters can be combined. src-ip
Frames are distributed based on source IP address. dst-ip
Frames are distributed based on destination IP address. src-port
Frames are distributed based on TCP/UDP source port number. dst-port
Frames are distributed based on TCP/UDP destination port number.
Command type
Configuration command
Default
src-ip
Message
% Cannot set same IP-Hash method.
Explanation
Parameters are duplicated.
Solution
Set non-duplicate parameters.
Example
Specifies destination IP address for the IP hash frame distribution function. xg(config)# link-aggregation load-balance ip-hash-selection src-ip
116/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.8 Uplink Filter Commands
This section explains the commands related to uplink filter configuration.
5.8.1 show uplink
Function
Display the configuration of uplink domains and the state of downlink member ports.
Prompt
xg>, or xg#
Command syntax show uplink
Command Type
Operation management command
Output form
xg(config)# show uplink
Uplink Domain Information 2006/03/17-14:35:25
===============================================================================
Domain Port-Function Ports-Membership
------ ---------------- -------------------------------------------------------
1 Uplink(Active) port 1 10 11
Uplink(Inactive) port 2
Downlink port 5 6
agg-port 2 3
2 Uplink(Active) port 3 4
Uplink(Inactive) None
Downlink port 5
agg-port 2
===============================================================================
Domain
The domain ID of the uplink group is displayed.
Port-Function
The port state belonging to the uplink domain is displayed.
Display Meaning
Uplink(Active)
Uplink(Inactive)
Downlink
Port-Membership
Defined Uplink port and link status is good.
Defined Uplink port and is NOT working. When the port becomes active, the port status will change.
Describes the member of downlink ports.
Display the port membership of the uplink domain.
Example
Display the uplink domain configuration. xg# show uplink
117/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.8.2 uplink-domain
Function
Create an uplink domain and assign member uplink ports.
Use the no form to release the domain membership.
Prompt
xg(config)#
Command syntax uplink-domain <1-20> port <1-20> [ <1-20> ] no uplink-domain <1-20>
Parameter
uplink-domain <1-20>
Specify a domain ID. The domain ID can be an integer of 1 to 20. port <1-20> [ <1-20> ]
Register or delete member uplink ports.
When specifying multiple ports, list them separated with " "(space).
Command type
Configuration command
Default
None
Message
% STP is enabled on uplink port. port %1$
Explanation
Uplink port assignments are not allowed for ports with STP enabled.
[[Inserted string]]%1$:port number
Solution
After disabling STP or configuring the port as portfast, execute the command again.
% port %1$ is member of aggregation-group.
Explanation
Uplink port assignments are not allowed for aggregation ports.
[[Inserted string]]%1$:port number
Solution
After releasing the ports from the aggregation group, execute the command again.
% port %1$ is included another uplink-domain.
Explanation
This uplink port is already a member of another uplink domain.
[[Inserted string]]%1$:port number
Solution
After releasing the uplink domain that includes the specified port, execute the command again.
% port %1$ is already downlink port in same uplink-domain.
Explanation
This port is a member of the downlink.
[[Inserted string]]%1$:port number
Solution
After releasing the member from the downlink, execute the command again.
% IGMP snooping is enabled.
Explanation
IGMP snooping is enabled.
Solution
After disabling IGMP snooping, execute the command again.
Note
Use this function only for ports to be configured after STP is disabled or portfast is enabled.
The member of an uplink domain is not permitted to be a member of an aggregation group.
When releasing an uplink domain using the no form, the members of downlink are also released.
IGMP snooping and the uplink function cannot be used at the same time. Execute "no ip snooping protocol igmp" command before configuring an uplink domain.
118/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Example
The following is an example of configuring port 3 and 4 as uplink ports of domain 3, and then, displaying the uplink domain information by using "show" command. xg(config)# uplink-domain 3 port 3 4 xg# show uplink
Uplink Domain Information 2006/03/17-14:35:25
===============================================================================
Domain Port-Function Ports-Membership
------ ---------------- -------------------------------------------------------
3 Uplink(Active) port 3 4
Uplink(Inactive) None
Downlink None
===============================================================================
119/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.8.3 downlink allowed uplink-domain
Function
Configure the downlink ports belonging to the uplink domain.
Use the no form to release the membership.
Prompt
xg(config-if)#, or xg(config-agg)#
Command syntax
downlink allowed uplink-domain { <1-20> | all } no downlink allowed uplink-domain { <1-20> | all }
Parameter
uplink-domain { <1-20> | all }
Specify the uplink domain ID for the member downlink ports.
− <1-20>
Specify a domain ID. The domain ID can be an integer of 1 to 20.
− all
Register or delete all uplink domains.
Command type
Configuration command
Default
None
Message
% Uplink-Domain %1$ is not configured. port %2$
Explanation
the uplink domain does not exist.
[[Inserted string]]%1$:uplink domain number
[[Inserted string]]%2$:port number
Solution
Create the uplink domain before executing this command.
% port %1$ is already uplink port in same uplink-domain.
Explanation
This port is a member of another uplink domain.
[[Inserted string]]%1$:port number
Solution
After releasing the port from the other uplink domain, execute the command again.
Note
The member of an uplink domain is not allowed to be the member of the corresponding downlink.
Aggregation groups can be assigned as a member of downlink.
If adding ports that are members of an aggregation group all port members of the aggregation group will automatically be made members of downlink.
When removing ports from an aggregation group that are also members of downlink, downlink membership does not automatically change.
Example
The following is an example of configuring port 3 as a member of uplink domain 1 and register port 4 as a downlink member of domain 1 then display the uplink domain information by using "show" command. xg(config)# uplink-domain 1 port 3 xg(config)# interface port 4 xg(config-if)# downlink allowed uplink-domain 1 xg(config-if)# exit xg(config)# exit xg# show uplink
Uplink Domain Information 2006/03/17-14:35:25
===============================================================================
Domain Port-Function Ports-Membership
------ ---------------- -------------------------------------------------------
1 Uplink(Active) port 3
Uplink(Inactive) None
Downlink port 4
===============================================================================
120/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.9 Switch Port Configuration Commands
This section explains the port specific commands of the switch.
5.9.1 show interface
Function
Displays the port state of the specified switch.
Prompt
xg> or xg#
Command syntax show interface [ { port <1-20> | agg-port <1-10> } ]
Parameter
port <1-20>
Specifies the port number of the switch to display.
agg-port <1-10>
Specifies the aggregation group number of the switch to display.
When the "port" parameter or "agg-port" parameter are omitted, the state of all ports will be displayed.
Command type
Operation management commands
Output form
xg# show interface
Interface Information 2007/01/22-12:12:15
===============================================================================
[port 1]
Generic Information
Description : port_name1
MAC Address : 000C.123a.4321
Link State : { Link-up | Link-down }
Link Status Detail : detail information
STP State : { Discard | Learn | Forward }
Flow Control : { Rx Only | Rx and Tx }
Address Learning : { Enabled | Disabled }
Multicast Forwarding : { Forward-all | Forward-unregistered-mac
| Filter-unregistered-mac }
Port Security : { Shutdown | Restrict | Disabled }
Storm Control : { Enabled | Disabled }
Default Qos Priority : <0-7>
Qos Egress Scheduling : { Strict | DRR | DRR-Strict }
Qos Bandwidth
Output Priority 0 : <0-10000>
Output Priority 1 : <0-10000>
Output Priority 2 : <0-10000>
Output Priority 3 : <0-10000>
Ingress Bandwidth : <40-10000> (total:<400-100000>)
Vlan Information
Port Default Vlan ID : <1-4094>
Vlan Member(tagged frame) : { None | Vlan-1 Vlan-2 }
Vlan Member(untagged frame) : { None | Vlan-1 Vlan-2 }
User Vlan Protocol ID : <0x05DD ~ 0xFFFF>
Filter Information
Ingress Filter(no vlan member): {Disabled | Enabled}
Ingress Filter(tagged frame) : {Disabled | Enabled}
Ingress Filter(untagged frame): {Disabled | Enabled}
-------------------------------------------------------------------------------
[port 2]
===============================================================================
The configuration and status of each switch port will be displayed.
[port 1]
The number of the switch port for the following information is displayed.
In the case of an aggregation group, the aggregation group number such as [agg-port 1] is displayed.
Generic Information
Description
Port description is displayed.
MAC Address
The MAC address of the port is displayed.
Link State
− Link-up
Shows the port is in a link down state.
− Link-down
Shows the port is in a link up state.
121/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Link Status Detail
Details of the port are displayed:
Display
PLUG-OUT The XFP is not installed.
LOW-PWR
PHY
CLI
The XFP is in low power state.
Access to the XFP failed.
The shutdown command was executed.
Meaning
TMR
AGG-MIN
LF
RF
LPT
SDL
PSL
LAL
Since the shutdown command and link-aggregation command were executed, the port is down for a certain period of time.
The number of ports in a link up state comprising an aggregation group became less than the minimum number of ports required to maintain a link up state.
A local fault was detected.
A remote fault was detected.
A link down state notification through the link pass through function occurred.
Frame discarding due to broadcast storm control was detected.
Frame discarding due to a port security violation was detected.
Frame discarding due to a loop back alert was detected.
SYS An internal system contradiction was detected.
STP State
− Disabled
The port is in a state to discard data traffic.
− Learn
The port is in the learning state. It prepares for forwarding data traffic. It discards data traffic.
− Forward
The port is ready to transmit data traffic.
Flow Control
− Rx Only
PAUSE flow control receive only is enabled.
− Rx and TX
PAUSE flow control send-receive is enabled.
Address Learning
− Enabled
Dynamic MAC address learning is enabled.
− Disabled
Dynamic MAC address learning is disabled.
Multicast Forwarding
− Forward-all
All multicast frames will be forwarded (flooded).
− Forward-unregistered-mac
Multicast addresses yet to be registered in the static MAC address table, and multicast addresses registered will be forwarded (flooded).
− Filter-unregistered-mac
Only Multicast addresses registered in the static MAC address table will be forwarded.
Port Security
− Shutdown
When a violating frame is detected, the port enters a violation state and goes link down.
− Restrict
When a violating frame is detected, the port enters a violation state, and the violating frame is discarded.
− Disabled
Port security is disabled.
Storm Control
− Enabled
Broadcast storm control is enabled.
− Disabled
Broadcast storm control is disabled.
Default Qos Priority
The QoS priority <0-7> is displayed.
Qos Egress Scheduling
− Strict
Forwarding is scheduled using strict priority.
− DRR
Forwarding is scheduled using round robin.
− DRR-Strict
Forwarding is scheduled using both strict priority and round robin.
Qos Bandwidth
Bandwidth for each output queue priority is displayed
Ingress Bandwidth
The ingress rate limiting value of the port is displayed in Mbps.
For an aggregation group, the ingress rate limiting value total "(total:<240-60000>)," is displayed.
122/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Vlan Information
Port Default Vlan ID
The default VLAN ID of the port is displayed.
Vlan Member (tagged frame)
Registered VLAN membership (tagged), is displayed.
If not registered as a VLAN member (tagged), "None" is displayed.
Vlan Member (untagged frame)
Registered VLAN membership (untagged), is displayed.
If not registered as a VLAN member (untagged), "None" is displayed.
User Vlan Protocol ID
User defined VLAN protocol identifier (User VLAN Protocol ID) is displayed as a hexadecimal value starting with 0x.
Filter Information
Ingress Filter (no vlan member)
The state of ingress filtering by VLAN ID is displayed.
− Disabled
The ingress filtering by VLAN ID is disabled.
− Enabled
The ingress filtering by VLAN ID is enabled.
Discards frames with VLAN ID that are not members, when received.
Ingress Filter (tagged frame)
The state of ingress filtering of a tagged frame is displayed.
− Disabled
The ingress filtering of a tagged frame is disabled.
− Enabled
The ingress filtering of a tagged frame is enabled.
Discards tagged frames when received.
Ingress Filter (untagged frame)
The state of ingress filtering of an untagged frame is displayed.
− Disabled
The ingress filtering of an untagged frame is disabled.
− Enabled
The ingress filtering of an untagged frame is enabled.
Discards untagged frames when they received.
Example
Display the state of the switch port 3. xg> show interface port 3
123/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.9.2 show port-description
Function
Displays information about port description.
Prompt
xg> or xg#
Command syntax
show port-description
Command type
Operation management commands.
Output form
xg# show port-description
Port Description Information 2007/05/10-17:50:54
===============================================================================
[agg-port 1]
Description: agg_name1
[agg-port 2]
Description: agg_name2
[port 1]
Description: port_nam1
[port 2]
Description: port_name2
[port 3]
Description: port_name3
===============================================================================
[port 1]
The number of the switch port for the following information is displayed.
In the case of an aggregation group, the aggregation group number such as [agg-port 1] is displayed.
Description
Port description is displayed
Example
Display the list of port description. xg> show port-description
124/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.9.3 shutdown (Administrator exec mode)
Function
Shuts down the port of a switch from the administrator exec mode, and turns off the optical signal at the XFP.
Use the no form to enable the port again.
Prompt
xg#
Command syntax shutdown port <1-20> [ <1-20> ] no shutdown port <1-20> [ <1-20> ]
Parameter
port <1-20> [ <1-20> ]
Specifies the port number to shut down or enable.
When specifying multiple port numbers, list them separated with " " (space).
Command type
Operation management commands
Example
Shut down switch ports 3 and 4. Then, make them usable again. xg# shutdown port 3 4 xg# no shutdown port 3 4
5.9.4 clear violation
Function
When a violation due to port security, loop back alert, and broadcast storm control is detected, an error log entry for the violation is output only once, and the target port will be set to a violation state. Violations can be checked with the "Link Status
Detail" displayed by the "show interface" command.
By using this command, the violation state of the port will be cleared.
If a violation state occurs, execute this command after eliminating the cause of the violation. If the cause of the violation is not fully eliminated, the violation state will recur.
Prompt
xg#
Command syntax clear violation { all | port <1-20> | agg-port <1-10> }
Parameter
all
Clears the violation state of all ports. port <1-20>
Specifies the port to be cleared. agg-port <1-10>
Specifies the aggregation group number to be cleared.
Command type
Operation management commands
Example
Clear the violation state of all ports. xg# clear violation all
125/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.9.5 interface port
Function
Switches from the global configuration mode to the interface edit mode wherein ports are configured.
Multiple ports can be configured collectively.
Prompt
xg(config)#
Command syntax interface port <1-20> [ <1-20> ] interface port range <1-20> <1-20> interface agg-port <1-10>
Parameter
port <1-20> [ <1-20> ]
Specifies the port to configure. When specifying multiple ports, list them separated with
" " (space). port range <1-20> <1-20>
Specifies the range of multiple ports to configure by separating with " " (space). agg-port <1-10>
Specifies the aggregation group number to configure. Multiple aggregation groups cannot be specified.
Command type
Configuration command
Message
% duplicate port number: %1$
Explanation
The specified port number was duplicated.
[[Inserted string]]%1$: specified switch port number
Solution
Specify a switch unique port numbers.
Note
When multiple ports are collectively configured, their settings are individually displayed when using such commands as
"copy running-config startup-config" or "show running-config".
Example
Switch to the collective interface edit mode using port numbers in the range of 1 to 8. xg(config)# interface port range 1 8 xg(config-if)#
Switch to the collective interface edit mode using port numbers 1, 3, 5, and 7. xg(config)# interface port 1 3 5 7 xg(config-if)#
Switch to the interface edit mode using aggregation group number 1. xg(config)# interface agg-port 1 xg(config-agg)#
When configuring an aggregation group, the prompt is displayed as (config-agg).
126/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.9.6 description
Function
Describes the port.
Use the no form to delete the port description.
Prompt
xg(config-if)# or xg(config-agg)#
Command syntax
description DESCRIPTION no description
Parameter
description_DESCRIPTION
Describes the port using ASCII characters. The description can be up to 64 alphanumeric characters in length.
No need to enclose a parameter in quotes if it contains a blank space.
Command type
Configuration command.
Default
None.
Message
% Port description length is max over.
Explanation
The port description length exceeded 64 characters.
Solution
Specify a port description consisting of up to 64 alphanumeric characters.
Note
Port descriptions are not checked for duplication.
Example
Describes port 3 as “port_name3”. xg(config)# interface port 3 xg(config-if)# description port_name3
127/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.9.7 flowcontrol
Function
Sets flow control transmission and reception modes pause frames. The receive only mode of flow control is always enabled.
Use the no form to return to the default setup.
Prompt
xg(config-if)# or xg(config-agg)#
Command syntax flowcontrol { only-receive | send-receive } no flowcontrol
Parameter
only-receive
Enables the receive only mode of flow control for the designated switch ports. send-receive
Enables the send-receive mode of flow control for the designated switch ports. If set, a pause frame is transmitted when the frame transmission buffer space runs out.
Command type
Configuration command
Default
only-receive
Example
Enable flow control for sending and receiving pause frames. xg(config-if)# flowcontrol send-receive
128/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.9.8 storm-control
Function
Enables broadcast storm control for the designated ports.
Use the no form to disable storm control.
Prompt
xg(config-if)# or xg(config-agg)#
Command syntax storm-control no storm-control
Command type
Configuration command
Default
None
Note
When a broadcast storm condition is detected, the port will be in a violation state. After eliminating the cause of the condition, clear the violation state with the "clear violation" command.
Example
Enable broadcast storm control for Port 3 of the switch. xg(config)# interface port 3 xg(config-if)# storm-control
5.9.9 suppress-address-learning
Function
Disables the dynamic learning of the MAC address table for switch ports.
Use the no form to enable learning.
Prompt
xg(config-if)#, or xg(config-agg)#
Command syntax suppress-address-learning no suppress-address-learning
Command type
Configuration command
Default
None
Example
Disable dynamic learning for the MAC address table. xg(config-if)# suppress-address-learning
129/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.9.10 shutdown (Interface edit mode)
Function
Shuts down the ports so that they cannot be used.
Use the no form to enable the ports again.
Prompt
xg(config-if)# or xg(config-agg)#
Command syntax shutdown no shutdown
Command type
Configuration command
Default
None
Note
When this command is invoked, the port becomes disabled but the optical signal from the XFP is not stopped.
Example
Shut down switch port 3. Then, make it usable again. xg(config)# interface port 3 xg(config-if)# shutdown xg(config-if)# no shutdown
5.9.11 shutdown (Global configuration mode)
Function
Shuts down the ports from the global configuration mode so that they cannot be used.
Use the no form to enable the ports again.
Prompt
xg(config)#
Command syntax shutdown port <1-20> [ <1-20> ] no shutdown port <1-20> [ <1-20> ]
Parameter
port <1-20> [ <1-20> ]
Specifies the port number to shut down or enable.
When specifying multiple ports, list them separated with " " (space).
Command type
Configuration command
Default
None
Note
When this command is invoked, the port becomes disabled, but the optical signal from the XFP is not stopped.
To shut down an aggregation group, use the interface edit mode shutdown command.
Example
Shut down switch ports 3 and 4 then, make them usable again. xg(config)# shutdown port 3 4 xg(config)# no shutdown port 3 4
130/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.9.12 port-security
Function
Sets port security based on the source MAC address.
When port security is enabled, register the MAC addresses permitted using the "bridge mac-address-table" command.
Use the no form to disable port security.
Prompt
xg(config-if)# or xg(config-agg)#
Command syntax port-security violation { restrict | shutdown } no port-security
Parameter
violation { restrict | shutdown }
Specifies the action when receiving a violating frame.
− restrict
When a violating frame is detected an error log entry is recorded, and an SNMP trap message is sent.
The violating frame is discarded, and the port set to a violation state.
− shutdown
When a violating frame is detected an error log entry is recorded, and an SNMP trap message is sent.
The port is set to a violation state then goes link down.
Command type
Configuration command
Default
None
Note
When a security violation is detected, the port is set to a in violation state. The "Link Status Detail" of the "show interface" command will display "PSL".
After eliminating the cause of the violation, clear the violation state with the "clear violation" command to return the port to usable state.
When port security is enabled, throughput decreases by about 10%, since the forwarding overhead increases. Also, receiving a frame that causes a security violation affects transmission from the port. Therefore, in an environment where security violations occur frequently, a decrease in the transmission rate should be anticipated.
Example
Set port security to switch port 3.
Then, when port 3 is in violation, check the port state using the "show interface" command.
After eliminating the cause of violation, make it usable again using the "clear violation" command. xg(config)# interface port 3 xg(config-if)# port-security violation shutdown xg(config-if)#exit xg(config)#exit
-
← When the port is in violation state. xg#show interface port 3
-
← When link Status Detail is "PSL." xg# clear violation port 3
131/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.9.13 link-pass-through
Function
Link pass through is a function that monitors the link state of a specific port, and, by synchronizing the link state of the specified port, promptly notifies changes of the link state to devices connected to the notification (domino) port.
This command specifies the link state monitoring port and the notification port.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax link-pass-through { monitored-port <1-20> | monitored-agg-port <1-10>}
[domino-port <1-20> [<1-20> ]] [domino-agg-port <1-10> [<1-10> ]] no link-pass-through { monitored-port <1-20> | monitored-agg-port <1-10>}
Parameter
monitored-port <1-20>
Specifies a port to monitor the link state.
monitored-agg-port <1-10>
Specifies an aggregation group to monitor the link state.
domino-port <1-20> [<1-20> ]
Specifies the port number for the link state notification.
When specifying multiple port numbers, list them separated with " " (space). domino-agg-port <1-10> [<1-10> ]
Specifies the aggregation group number for the link state notification.
When specifying multiple aggregation group numbers, list them separated with " " (space).
Command type
Configuration command
Default
None
Message
% Agg-port %1$ does not exist.
Explanation
The specified aggregation group is not created.
[[Inserted string]]%1$: specified aggregation group number
Solution
Review the specified aggregation group numbers.
% monitored-port and domino-port cannot specify a port belonging to an aggregation port. port=%d¥n
Explanation
Ports within a link aggregation group cannot be specified as monitored and domino ports.
[[Inserted string]]%1$: port number specified to monitored-port or domino-port
Solution
Review the ports specified as monitored and domino ports.
% Cannot set same port number in monitored-port and domino-port. port %1$
Explanation
The same port number cannot be set to a monitored port and a domino port.
[[Inserted string]]%1$: port number
Solution
Review the parameter specified for the monitored port or domino port.
% Cannot set same aggregation port number in monitored-agg-port and domino-agg-port. agg-port %1$
Explanation
The same aggregation group number cannot be set to a monitored port and a domino agg-port.
[[Inserted string]]%1$: aggregation group number
Solution
Review the parameters specified for the monitored port or domino agg-port.
% Cannot set same port number in domino-port. port %1$
Explanation
The same port number cannot be set as the domino port.
[[Inserted string]]%1$: port number
Solution
Review the parameter specified for the domino port.
% Cannot set same aggregation port number in domino-agg-port. agg-port %1$
Explanation
The same aggregation group number cannot be set as the domino agg-port.
[[Inserted string]]%1$: aggregation group number
Solution
Review the parameter specified for the domino agg-port.
Example
Monitor the link state of aggregation group 1 and set ports 4 and 5 to receive link state notification. xg(config)# link-pass-through monitored-agg-port 1 domino-port 4 5
132/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.9.14 ingress-bandwidth
Function
Sets the ingress rate limiting value for the designated ports.
When reception traffic exceeds the ingress rate limiting value, received frames will be discarded.
Use the no form to return to the default setup.
Prompt
xg(config)# or xg(config-agg)#
Command syntax ingress-bandwidth <40-10000> no ingress-bandwidth
Parameter
<40-10000>
Specifies the ingress rate limiting value in the range of 40 to 10000 Mbps. The value must be an integer divisible by 40.
For an aggregation group, the specified ingress rate limiting value applies to each port comprising the aggregation group. The total ingress rate limiting value for the aggregation group will be the specified ingress rate limiting value multiplied by the number of ports.
Command type
Configuration command
Default
10000
Message
% The set value is not step of 40.
Explanation
The specified ingress rate limiting value is not an integer divisible by 40.
Solution
Specify the ingress rate limiting value with an integer divisible by 40.
Note
For the specified ingress rate limiting value x, the actual ingress rate limiting value used is expressed in the approximation below.
Actual ingress rate limiting value = {integral part of (rate 256 / 10000)} 10000 / 256
Measurement of the ingress rate is done in increments of 100
µs. Therefore, when burst transfers are performed that exceed 100
µs, the actual permitted ingress rate will be smaller than the specified value.
Example
Set the ingress rate of port 3 to 5Gbps. xg(config)# interface port 3 xg(config-if)# ingress-bandwidth 5000
133/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.9.15 multicast-forwarding
Function
Sets the forwarding method for multicast frames.
Use the no form to return to the default setup.
Prompt
xg(config)# or xg(config-agg)#
Command syntax multicast-forwarding { forward-all | forward-unregistered-mac | filter-unregistered-mac } no multicast-forwarding
Parameter
{ forward-all | forward-unregistered-mac | filter-unregistered-mac }
Specifies the forwarding method for multicast frames.
− Forward-all
All multicast frames will be forwarded (flooded).
− Forward-unregistered-mac
Multicast addresses yet to be registered in the static MAC address table, and multicast addresses registered will be forwarded (flooded). Multicast addresses registered as non-member ports will be filtered.
− Filter-unregistered-mac
Only Multicast addresses registered as member ports in the static MAC address table will be forwarded.
Command type
Configuration command
Default
forward-all
Example
Enter the interface edit mode using switch ports 1 to 3, then set them to the unregistered multicast forwarding mode. xg(config)# interface port range 1 3 xg(config-if)# multicast-forwarding forward-unregistered-mac
134/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.10 Spanning Tree Protocol (STP) Configuration
Commands
This section explains the commands related to the Spanning Tree Protocol.
5.10.1 show spanning-tree
Function
Displays the state of the Spanning Tree Protocol.
Prompt
xg> or xg#
Command syntax show spanning-tree [ detail [ { port <1-20> | agg-port <1-10> } ] ]
Parameter
detail
Displays the state of the Spanning Tree Protocol configuration in detail.
When this parameter is omitted, the display will be simplified. port <1-20>
Specifies the ports to display. agg-port <1-10>
Specifies the aggregation groups to display.
When "port" parameter and "agg-port" parameter are omitted, the state of all ports will be displayed.
Command type
Operation management commands
Output form (simplified display)
xg# show spanning-tree
Spanning Tree Information 2007/01/22-12:12:15
===============================================================================
Switch Information for Spanning Tree
-----------------------------------------------------------------
Spanning Tree : {Enabled | Disabled}
Root Switch Priority: 32768
Root Switch ID : 8000.0080.17C2.0511
Root Path Cost : 0
Root Port : port1
Switch Priority : 32768
Switch ID : 8001.0080.17C2.0512
Max Age : 20 (sec)
Hello Time : 2 (sec)
Forward Time : 15 (sec)
Topology Changes : 0
Last Topology Change: 2007/01/22-12:12:15
portfast errdisable : {enabled | disabled}
timeout
portfast errdisable : 300 sec
timeout interval
-----------------------------------------------------------------
Ports Information for Spanning Tree
-----------------------------------------------------------------
Port State Mode Cost Pri PortID Flags Designated Switch
---- ---------- ---- ------ ------ ------ -------------------
1 Forward RSTP 2000 128 32769 Rpp-w 8000.0080.17C2.0511
2 Discard RSTP 2000 128 32770 Bpp-w 8000.0080.17C2.0511
3 Learn RSTP 2000 128 32771 Bpp-w 8001.0080.17C2.0512
4 Forward RSTP 2000 128 32772 Dpp-- 8001.0080.17C2.0512
5 Down RSTP 0 128 32773 ----- 0000.0000.0000.0000
6 Down None 0 128 32774 ----- 0000.0000.0000.0000
7 Down None 0 128 32775 ----- 0000.0000.0000.0000
8 Down None 0 128 32776 ----- 0000.0000.0000.0000
9 Down None 0 128 32777 ----- 0000.0000.0000.0000
10 Down None 0 128 32778 ----- 0000.0000.0000.0000
11 Down None 0 128 32779 ----- 0000.0000.0000.0000
12 Down None 0 128 32780 ----- 0000.0000.0000.0000
-----------------------------------------------------------------
Flags
1: (Port role) R=Root, D=Designated, A=Alternate, B=Backup
2: (Config type) p=Point-to-point, s=Shared
3: (Oper. type) p=Point-to-point, s=Shared
4: (Proposal state) p=Proposing
5: (Received BPDU) d=802.1d, w=802.1w
===============================================================================
135/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Switch Information for Spanning Tree
General Spanning Tree Protocol information is displayed.
Spanning Tree
The operational state of the Spanning Tree Protocol is displayed.
− Disabled
Spanning Tree Protocol is disabled.
− Enabled
Spanning Tree Protocol is enabled.
Root Switch Priority
The priority value for the switch selected as the root switch is displayed as a decimal number.
Root Switch ID
The switch identifier selected as the root switch is displayed.
The first four digits representing the priority of the root switch are displayed as a hexadecimal number.
The remaining 12 digits representing the MAC address of the root switch are displayed as a hexadecimal number.
Root Path Cost
The path cost value from the device to the root switch.
When the device is the root switch, "0" is displayed.
Root Port
The switch port number of the root port of the device is displayed.
When the device is the root switch, "---" is displayed.
Switch Priority
The priority value of the device is displayed as a decimal number.
Switch ID
The switch identifier priority for the device is displayed.
The first four digits representing the priority of the device are displayed as a hexadecimal number.
The remaining 12 digits representing the MAC address of the device are displayed as a hexadecimal number.
Max Age
The maximum valid time (seconds) for BPDU's are displayed.
Hello Time
The transmit interval (seconds) for BPDU's are displayed.
Forward Time
The time a port requires to switch states.
Topology Changes
The number of times the topology changed is displayed.
Last Topology Change
The latest date and time the topology change occurred is displayed. portfast errdisable timeout
The state of errdisable-timeout function is displayed.
− disabled
The errdisable-timeout function is disabled.
− enabled
The errdisable-timeout function is enabled. portfast errdisable timeout interval
The timeout value (seconds) for canceling a port down condition when the errdisable-timeout function is enabled is displayed.
Ports Information for Spanning Tree
The Spanning Tree Protocol information for each switch port is displayed.
Port
The switch port number is displayed.
Port State
The STP state of the switch port is displayed.
− Down
Indicates that the switch port is in link down state.
− Discard
The switch port does not send/receive frames other than BPDUs.
− Learn
The switch port is in learning state. The source MAC address for received frames is learned, but frames are not forwarded.
− Forward
The switch port is ready to transmit data traffic.
For RSTP (IEEE802.1w), "Blocking" and "Listening" states of STP are merged as the "Discarding"
State. The port states between STP (IEEE802.1D) and RSTP (IEEE802.1w) correspond as follows:
Display format
STP(IEEE802.1D)
Block Blocking
RSTP(IEEE802.1w)
Discarding
Listen Listening
Learn Learning
Forward Forwarding
Discarding
Learning
Forwarding
For a switch port that does not use STP, the state will be either "Forward" or "Down."
136/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Mode
The switch port mode of the Spanning Tree Protocol is displayed.
− STP
The switch port is operating in STP (IEEE 802.1D Spanning Tree Protocol) mode.
− RSTP
The switch port is operating in RSTP (IEEE 802.1w Rapid Spanning Tree Protocol) mode.
− None
STP is not applicable to the switch port.
Cost
The path cost value of the port is displayed.
Pri
The priority value of the switch port is displayed.
PortID
The port ID of the switch port is displayed.
Flags
Flags indicating the state of the switch port are displayed. Each flag has the following meaning:
− First flag (Port role)
Indicates the role of the port.
− R
The Root port.
− D
The Designated port.
− A
The Alternate port.
− B
The Backup port.
− Second flag (Config link type)
Indicates the link type of the line configured in the device.
− p
A point-to-point link.
− s
A shared line.
In the device Point-to point "p" is always used.
− Third flag (Oper link type)
Indicates the link type in operation.
− p
A point-to-point link.
− s
A shared link.
− Fourth flag (Proposal state)
Indicates a Spanning Tree was proposed by an adjacent switch.
− p
Building a Spanning Tree was proposed.
− (None)
Building a Spanning Tree request was accepted by the adjacent switch.
− Fifth flag (Received BPDU)
The Spanning Tree Protocol mode for the received BPDU.
− d
STP(IEEE802.1D).
− w
RSTP(IEEE802.1w).
If the destination switch port is operating in STP (IEEE802.1D) mode, the connected device switch port will operate in STP mode regardless of its setting.
Designated Switch
Displays the switch identifier for the specified switch that sent a BPDU to the specified port.
The first four digits representing the priority of the designated switch are displayed as a hexadecimal number. The remaining 12 digits representing the MAC address of the designated switch are displayed as a hexadecimal number.
137/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Output form (detailed display)
xg# show spanning-tree detail
Spanning Tree Information 2007/01/22-12:12:15
===============================================================================
Switch Information for Spanning Tree
---------------------------------------------------------------
Spanning Tree : {Enable | Disable}
Root Switch Priority: 32768
Root Switch ID : 8000.0080.17C2.0511
Root Path Cost : 6
Root Port : port-1
Switch Priority : 32769
Switch ID : 8001.0080.17C2.0512
Max Age : 20 (sec)
Hello Time : 2 (sec)
Forward Time : 15 (sec)
Topology Changes : 0
Last Topology Change: 2007/01/22-12:12:15
portfast errdisable : {enabled | disabled}
timeout
portfast errdisable : 300 sec
timeout interval
----------------------------------------------------------------
Ports Information for Spanning Tree
-----------------------------------------------------------------------------
[Port 1]
STP State : {Down | Discard | Learn | Forward }
STP Mode : {STP | RSTP | None}
Port ID : 32772
Role : {Root | Designated | Alternate | Backup}
Path Cost : 2
Link Type : { Point-to-point | Shared }
Forward-Transitions : 0
Portfast : {Disabled | Enabled}
Portfast bpdu-guard : {Disabled | Enabled}
Portfast bpdu-filter: {Disabled | Enabled}
BPDU Parameter
Designated Path Cost: 0
Designated Port ID : 0
Designated Priority : 128
Designated Root ID : 0000.0000.0000.0000
Designated Switch ID: 0000.0000.0000.0000
Max Age : 20 (sec)
Message Age : 0 (sec)
Message Age Timer : 0 (sec)
Hello Time : 2 (sec)
Hello Timer : 0 (sec)
Forward Time : 15 (sec)
Forward Timer : 0 (sec)
Received STP Protocol: None
[Port 2]
-----------------------------------------------------------------------------
=============================================================================
Switch Information for Spanning Tree
General Spanning Tree Protocol information is displayed.
The display content is the same as that of the simplified display except for some additional items.
Port Information for Spanning Tree
Spanning Tree Protocol information for each port is displayed.
[Port 1]
The switch port number is displayed.
STP State
The state of the port is displayed.
The display content is the same as that of the simplified display.
STP Mode
The Spanning Tree Protocol mode is displayed. The display content is the same as that of the simplified display.
Port ID
The Port ID of the switch port is displayed.
Role
The role of the port is displayed.
− Root
The root Port.
− Designated
The designated port.
− Alternate
The alternate port.
− Backup
The backup port.
Path Cost
The path cost for the port is displayed.
138/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Link Type
Indicates the state of the current link.
− Point-to-point
A point-to-point link.
− Shared
A shared link.
Forward-Transitions
Displays the number of times the port changed to forwarding state.
Portfast
The Portfast state is displayed.
− Disabled
The Portfast function is disabled.
− Enabled
The Portfast function is enabled.
Portfast bpdu-guard
The state of the BPDU guard function is displayed.
− Disabled
The BPDU guard function is disabled.
− Enabled
The BPDU guard function is enabled.
Portfast bpdu-filter
The state of the BPDU filter function is displayed.
− Disabled
The BPDU filter function is disabled.
− Enabled
The BPDU filter function is enabled.
BPDU Parameter
Displays the information about the BPDU send/receive.
This is only displayed when the "STP State" of the specified port is not "Down".
Designated Path Cost
The root path cost to the destination port is displayed.
Designated Port ID
The Port ID of the destination port is displayed.
Designated Priority
The priority value of the destination port is displayed,
Designated Root ID
The switch identifier of the root switch registered in the destination switch is displayed.
The first four digits representing the priority of the root switch are displayed as a hexadecimal number. The remaining 12 digits representing the MAC address of the root switch are displayed as a hexadecimal number.
Designated Switch ID
The switch identifier of the destination switch is displayed.
The first four digits representing the priority of the designated switch are displayed as a hexadecimal number.
If the "Designated Root ID" and the "Designated Switch ID" are the same, the destination switch is the root switch.
Max Age
The maximum valid time (seconds) for BPDU's for the destination switch is displayed.
Message Age
Displays the time (seconds) lapsed since the last BPDU message from the destination switch was received.
Message Age Timer
Displays the timeout value (seconds) for BPDU messages sent form the destination switch.
Hello Time
Displays the hello time (seconds) sent from the destination switch.
Hello Timer
Displays the remaining seconds for the Hello Timer. When it decrements to 0, a BPDU is sent.
Forward Time
Displays the Forward Time (seconds) sent from the destination switch.
Forward Timer
Displays the remaining seconds for the Forward Timer. When it decrements to 0, the status of the port is changed.
Received STP Protocol
Displays the Spanning Tree Protocol (STP) mode of the destination switch.
− STP
The connection destination switch is operating in STP (IEEE 802.1D) mode.
− RSTP
The connection destination switch is operating in RSTP (IEEE 802.1w) mode.
− None
STP is not enabled on the destination switch.
Example
Displays the detailed information for the Spanning Tree Protocol state: xg# show spanning-tree detail
139/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.10.2 spanning-tree
Function
Enables the Spanning Tree Protocol (STP).
Use the no form to disable Spanning Tree Protocol.
Prompt
xg(config)#
Command syntax spanning-tree no spanning-tree
Command type
Configuration command
Default
None
Message
% port %1$ is membership of uplink-domain %2$.
Explanation
The specified port already belongs to an uplink domain.
[[Inserted string]]%1$: specified port number
[[Inserted string]]%2$: uplink domain number
Solution
Specify a port not belonging to an uplink domain or remove the port from an uplink domain.
Note
STP cannot be used on uplink ports. STP port fast, however, is allowed on uplink ports.
Example
Enable Spanning Tree Protocol. xg(config)# spanning-tree
140/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.10.3 spanning-tree priority
Function
Sets the switch priority of the Spanning Tree Protocol.
Whichever switch priority is smallest is selected as the root switch for the Spanning Tree.
Use the no form to return to the default state.
Prompt
xg(config)#
Command syntax spanning-tree priority <0-61440> no spanning-tree priority
Parameter
priority <0-61440>
Sets the switch priority value. It must be an integer divisible by 4096. Values can be set in the range of 0 to 61440.
Command type
Configuration command.
Default
32768
Message
% Priority is not step of 4096
Explanation
The priority is not a multiple of 4096.
Solution
Specify an integer divisible by 4096.
Example
Set the switch priority to 4096. xg(config)# spanning-tree priority 4096
141/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.10.4 spanning-tree hello-time
Function
The hello time is a time interval between BPDUs. Periodic BPDUs inform all the other switches on the network of the root switch routing information.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax spanning-tree hello-time <2-10> no spanning-tree hello-time
Parameter
hello-time <2-10>
Specify a hello time in seconds.
Command type
Configuration command
Default
2 seconds
Message
% Can't set hello-time
Explanation
An unsettable value was specified. The settable range of "hello-time" differs depending on the values of "forward-time" and "max-age".
Solution
Set a value which satisfies the conditions specified in this Section's Notes.
Note
If the hello time is short, topology changes can be detected more quickly, but STP traffic and STP processing overhead will increase.
The settable range of hello-time differs depending on the values set with the "spanning-tree max-age" command and the "spanning-tree forward-time" command. The value must also satisfy the following conditions:
2 (forward_time - 1)
≥ max_age max_age
≥ 2 (hello_time + 1)
Example
Set the hello time value of the Spanning Tree switch to 3 seconds. xg(config)# spanning-tree hello-time 3
142/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.10.5 spanning-tree max-age
Function
The maximum age (max-age) of the Spanning Tree is the maximum valid time interval between received BPDUs. When
BPDUs are not received within that time, the topology of the Spanning Tree will be recalculated, and the switch that timed out will send BPDUs acting as a root switch.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax spanning-tree max-age <6-40> no spanning-tree max-age
Parameter
max-age <6-40>
Sets the timeout value for the received BPDUs. When the switch does not receive BPDUs within this period, the topology of the Spanning Tree will be recalculated. Values can be set in the range of 6 to 40 seconds.
Command type
Configuration command
Default
20 seconds
Message
% Can't set max-age.
Explanation
An unsettable value was specified. The settable range of max-age differs depending on the values of "hello-time" and "forward-time".
Solution
Set a value, which satisfies the conditions as detailed in this Section's Notes.
Note
The settable range of maximum age differs depending on the value set with the "spanning tree hello-time" command and the "spanning tree forward-time" command. The value must also satisfy the following conditions:
2 (forward_time -1)
≥ max_age max_age
≥ 2 (hello_time + 1)
Example
Specify the maximum age (max-age) value of the Spanning Tree to 30 seconds. xg(config)# spanning-tree max-age 30
143/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.10.6 spanning-tree forward-time
Function
The forward delay time of the Spanning Tree is the time required for the ports to change to a forwarding state.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax spanning-tree forward-time <4-30> no spanning-tree forward-time
Parameter
forward-time <4-30>
Specifies the forward delay time for the Spanning Tree in seconds. Values can be set in the range of 4 to 30 seconds.
Command type
Configuration command
Default
15 seconds
Message
% Can't set forward-time.
Explanation
An unsettable value was specified. The settable range of "forward-time" differs depending on the values of "hello-time" and "max-age".
Solution
Set a value, which satisfies the conditions in this Section's Notes.
Note
The settable range of forward delay time differs depending on the values set with the "spanning-tree hell-time" command and the "spanning-tree max-age" command. The value must also satisfy the following conditions:
2 (forward_time - 1)
≥ max_age max_age
≥ 2 (hello_time + 1)
Example
Specify the forward delay time value to 17 seconds. xg(config)# spanning-tree forward-time 17
144/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.10.7 spanning-tree port-priority
Function
Sets a port priority within the Spanning Tree.
A smaller value has a higher priority.
Use the no form to return to the default setup.
Prompt
xg(config-if)# or xg(config-agg)#
Command syntax spanning-tree port-priority <0-240> no spanning-tree port-priority
Parameter
port-priority <0-240>
Specifies a port priority value within the Spanning Tree. Specify a value divisible by 16.
It can be within the range of 0 to 240.
Command type
Configuration command
Default
128
Message
% Priority is not step of 16
Explanation
The priority value specified is not an integer divisible by 16.
Solution
Specify a priority value divisible by 16.
Example
Set the priority of port2 to 160. xg(config)# interface port 2 xg(config-if)# spanning-tree port-priority 160
5.10.8 spanning-tree port-path-cost
Function
Sets a path cost for each port.
Use the no form to return to the default setup.
Prompt
xg(config-if)# or xg(config-agg)#
Command syntax spanning-tree port-path-cost <1-200000000> no spanning-tree port-path-cost
Parameter
port-path-cost <1-200000000>
Sets a path cost for each port. It can be within the range of 1 to 200000000.
The following path cost values are recommended by IEEE802.1D.
Link speed IEEE802.1D (16bit) IEEE802.1D (32bit)
Recommended range
20000 - 2000000
2000 - 200000
200 - 20000
Recommended value
200000
20000
2000
100M bps
1G bps
10G bps
Recommended range
10 - 60
3 - 10
1 - 5
Recommended value
19
4
2
Command type
Configuration command
Configuration command Default
2 (16bit)
2000 (32bit)
Example
Set the path cost for port 2 to 3: xg(config)# interface port 2 xg(config-if)# spanning-tree port-path-cost 3
145/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.10.9 spanning-tree path-cost-default
Function
Sets the version of path cost (IEEE802.1D: 16bits or IEEE802.1D:32bits) to be used for the Spanning Tree Protocol.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax spanning-tree path-cost-default { 16bit | 32bit } no spanning-tree path-cost-default
Parameter
path-cost-default { 16bit | 32bit }
− 16bit
IEEE802.1D (16bits) will be used for the path cost. The default path cost is 2.
− 32bit
IEEE802.1D (32bits) will be used for the path cost. The default path cost is 2000.
Command type
Configuration command
Default
32bit
Message
% The Setting becomes an availableness by doing REBOOT.
Explanation
The settings changed will become valid when the system is restarted.
Solution
To make the settings valid, issue the “copy running-config startup-config” command first.
Then, issue the “reset” command to restart the system.
Example
Use the 32-bit path cost: xg(config)# spanning-tree path-cost-default 32bit
146/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.10.10 spanning-tree portfast
Function
The “portfast” function reduces the transition time required to transition to a "Forwarding" state. When the function is enabled, the port state is directly changed from "Discarding" to "Forwarding" and does not transition to a "Listening" or Learning" state.
This function can only be used with an edge port that is directly connected to a terminal node.
Use the no form to return to the default setup.
Prompt
xg(config-if)# or xg(config-agg)#
Command syntax spanning-tree portfast no spanning-tree portfast
Parameter
portfast
Enables the portfast function.
Command type
Configuration command
Default
None
Message
% port %1$ is membership of uplink-domain %2$.
Explanation
The specified port already belongs to an uplink domain.
[[Inserted string]]%1$: specified port number
[[Inserted string]]%2$: uplink domain number
Solution
Specify a port not belonging to an uplink domain or remove the port from its uplink domain.
Note
Use this function only for ports connected as an edge switch or for a port directly connected to a terminal node.
If this function is applied to other ports, an unrecoverable loop condition will occur thereby affecting the switch and network operations may be affected.
The port must be removed from an uplink domain before enabling the STP portfast function.
Example
Enable portfast for switch port 2. xg(config)# interface port 2 xg(config-if)# spanning-tree portfast
147/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.10.11 spanning-tree portfast bpdu-guard
Function
Enable the BPDU guard function for a port within portfast enabled.
When BPDU guard enabled port receives a BPDU, the port is shut down and its communication fails. During this time, the received BPDU is not processed.
If the port is shut down, re-enable the communication either by using the “no shutdown” command or the “spanning-tree portfast errdisable-timeout” command thereby automatically restarting the communication after the err-disable timeout.
Use the no form to return to the default setup.
Prompt
xg(config-if)# or xg(config-agg)#
Command syntax spanning-tree portfast bpdu-guard no spanning-tree portfast bpdu-guard
Parameter
portfast bpdu-guard
Enables the BPDU guard.
Command type
Configuration command
Default
None
Note
The function is enabled for the port only if portfast was previously enabled on the port.
Example
Enables the portfast function and BPDU guard function for port 2. xg(config)# interface port 2 xg(config-if)# spanning-tree portfast xg(config-if)# spanning-tree portfast bpdu-guard
5.10.12 spanning-tree portfast errdisable-timeout
Function
Starts the timer that automatically releases a port from a shutdown state. This function is only valid for ports in wherein the portfast function and the BPDU guard function is enabled. This command is also used to specify a timer value.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax spanning-tree portfast errdisable-timeout [ interval <10-1000000> ] no spanning-tree portfast errdisable-timeout
Parameter
errdisable-timeout
Enables the timer to release the port automatically from the shutdown status using the BPDU card. interval <10-1000000>
Specifies the timeout value that automatically releases the port from a shutdown state. The value must be within the range of 10 to 1000000 seconds.
If this parameter is omitted, the value is set to 300 seconds.
Command type
Configuration command
Default
None
Note
Use this function only for ports connected to as an edge switch or for ports directly connected to a terminal node.
If this function is applied to other ports an unrecoverable loop condition will occur thereby affecting the switch and network operations.
Example
Enable the automatic release timer for the port in a shutdown state. xg(config)# spanning-tree portfast errdisable-timeout
148/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.10.13 spanning-tree portfast bpdu-filter
Function
Enable the BPDU filter for a portfast enabled port.
If BPDU filtering in enabled, the port does not send or receive a BPDU.
Use the no form to return to the default setup.
Prompt
xg(config-if)# or xg(config-agg)#
Command syntax spanning-tree portfast bpdu-filter no spanning-tree portfast bpdu-filter
Parameter
portfast bpdu-filter
Enables the BPDU filter for the port specified.
Command type
Configuration command
Default
None
Note
This function is only valid for portfast enabled ports.
Example
Enable BPDU filtering for port 2: xg(config)# interface port 2 xg(config-if)# spanning-tree portfast xg(config-if)# spanning-tree portfast bpdu-filter
149/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.11 Virtual LAN (VLAN) Setup Commands
This section explains the configuration commands related to Virtual LANs (VLAN).
5.11.1 show vlan
Function
Displays information about available VLANs and their member ports.
Prompt
xg> or xg#
Command syntax show vlan
[ <1-4094> ]
Parameter
vlan <1-4094>
Display specified VLAN and its total VLAN description.
When parameter is omitted, the state of all VLANs will be displayed. (VLAN description is displayed up to 19 characters)
Command type
Operation management command
Output form (no parameter)
xg# show vlan
Vlan Information 2007/01/22-14:35:25
===================================================================================
VID Vlan-Description Tag Ports-Membership
---- ------------------- ----- ----------------------------------------------------
1 default TAG agg-port 1 2 3 4 5 6
port 1 2 3 4 5 6 7 8 9 10
UNTAG port 11 12 13 14 15 16 17 18 19 20
2 VLAN002 TAG port 1 2 3
3 VLAN003 UNTAG port 1 2 3
4 VLAN004 --- None
===================================================================================
Output form (parameter is specified)
xg# show vlan 2
Vlan Information 2007/01/22-14:35:25
===================================================================================
VID 2
Vlan-Description: VLAN0002
Tag Ports-Membership
----- -------------------------------------------------------
TAG port 1 2 3
===================================================================================
VID
Displays the VLAN ID (VID).
Vlan-Description
Displays the description assigned to the VLAN. If no description is set, a description consisting of “VLAN” and a 4-digit VID number will be assigned.
Tag
Displays the VLAN tag configuration.
Items displayed
Meaning
TAG VLAN member (with a tag)
A frame having a VLAN tag will be forwarded.
UNTAG VLAN member (without a tag)
A frame having no VLAN tag will be forwarded.
Ports-Membership
Displays the member ports. If there are no member ports, "None" is displayed.
Example
Display the VLAN status. xg# show vlan
150/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.11.2 vlan
Function
Creates a VLAN. Also, a VLAN description may be specified to allow easy identification.
Up to 128 VLANs can be created.
Use the no form to delete the VLAN.
Prompt
xg(config)#
Command syntax vlan <1-4094> [ {description|name} VLAN_DESCRIPTION ] no vlan <2-4094>
Parameter
vlan <1-4094>
Specifies an ID for the VLAN to be created. The VLAN ID (or VID) can be an integer in the range of 1 to 4094.
The default VLAN ( VID = 1 and description “default”) cannot be deleted. description|name VLAN_DESCRIPTION
Describes the VLAN using ASCII characters. The description can be up to 256 alphanumeric characters in length.
The default VLAN description is “VLAN****” (where, **** is the VID). No need to enclose a parameter in quotes if it contains a blank space.
Command type
Configuration command
Default
The default VLAN (VID=1, VLAN description =default) is initially registered with all ports as members.
Message
% Argument is too long
Explanation
The VLAN description length exceeded 256 characters.
Solution
Specify a VLAN description consisting of up to 256 alphanumeric characters.
% Can't add vlan. Max entry over.
Explanation
No more VLANs can be created. The maximum VLAN entries (128 entries) allowed are registered on the system.
Solution
Delete unnecessary VLANs and reissue the command.
% Can't delete vlan. same pvid entry
Explanation
The VLAN cannot be deleted because the specified port was set to port VLAN ID
(“port-vlan-id”).
Solution
Make sure that each port VID is not the same as the VLAN ID. If not required, delete the port VID using the “no port-vlan-id” command. Then, delete the VLAN.
Note
VLAN descriptions are not checked for duplication. Specify a unique description for each VLAN on the network.
Example
First, create a VLAN having VID 2 and VLAN description “vlan-floor1”. Second, create a VLAN having VID 3 and VLAN description “vlan-floor2”.
Finally, check the VLAN descriptions using the “show vlan” command. xg(config)# vlan 2 description vlan-floor1 xg(config)# vlan 3 name vlan-floor2 xg(config)# exit xg# show vlan
Vlan Information 2007/01/22-16:20:15
==================================================================================
VID Vlan-Description Tag Ports-Membership
---- ------------------- ----- ----------------------------------------------------
1 default UNTAG port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
20
2 vlan-floor1 --- None
3 vlan-floor2 --- None
==================================================================================
151/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.11.3 Interface vlan
Function
Switches from the global configuration mode to the interface edit mode wherein VLANs are configured.
Multiple VLANs can be configured collectively.
Prompt
xg(config)#
Command syntax
interface vlan <1-4094> [ <1-4094> ]
Parameter
vlan <1-4094> [ <1-4094> ]
Specifies the VLAN to configure. When specifying multiple VLANs, list them separated with
" " (space). Up to 8 VIDs can be specified.
Command type
Configuration command
Message
% duplicate vlan number: %1$
Explanation
The specified VID was duplicated.
[[Inserted string]]%1$: duplicated VID
Solution
Specify a unique VID.
% Can't set vlan id. Over max entry number. [8]
Explanation
The maximum number of VID was exceeded.
Solution
Specify no more than 8 VIDs and execute the command again..
% VLAN %1$ not configured.
Explanation
The specified VLAN is not created.
[[Inserted string]]%1$: specified VID
Solution
Review the VLAN specified then execute the command again.
Note
Every command wherein VLAN edit mode is not displayed in “show running-config” command since equivalent commands are already exist.
Example
Switch to the collective interface edit mode using VLANs. xg(config)# interface vlan 1 2 3 xg(config-vlan)#
152/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.11.4 egress
Function
Registers a port as a VLAN member.
Use the no form to release the VLAN membership.
Prompt
xg(config-vlan)#
Command syntax egress { untagging | tagging } { port <1-20> | agg-port <1-10> } no egress { port <1-20> | agg-port <1-10> }
Parameter
untagging
Deletes a VLAN tag during frame transmission. tagging
Adds a VLAN tag during frame transmission. port <1-20>
Specifies a port for membership registration or deletion. agg-port <1-10>
Specifies an aggregation group for membership registration or deletion.
Command type
Configuration command
Default
Registers all ports with “egress-untagging” (the default VLAN).
Not set (except for the default VLAN)
Message
% cannot found port interface: %$1
Explanation
The specified port number is not found.
[[Inserted string]]%1$: Port number
Solution
Assign the specified port not to be a member of an aggregation group.
% cannot found agg-port interface: %$1
Explanation
The specified aggregation group is not found.
[[Inserted string]]%1$: Aggregation group number
Solution
Check whether the specified aggregation group number is correct.
% duplicate port number: %1$
Explanation
The specified port number was duplicated.
[[Inserted string]]%1$: specified switch port number
Solution
Specify a switch unique port numbers.
% duplicate agg-port number: %1$
Explanation
The specified aggregation group number was duplicated.
[[Inserted string]]%1$: specified aggregation group number
Solution
Specify an unique aggregation group number.
% Can't remove vlan from port. Same pvid entry. %1$
Explanation
The specified VID cannot be deleted because it is identical to the default PVID.
[[Inserted string]]%1$: Port number
Solution
Change the default PVID and reissue the command.
Example
The following example shows registering port 20 as members of VLAN 1, 2 and 3 (with untag). xg(config)# interface vlan 1 2 3 xg(config-vlan)# egress untagging port 20
153/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.11.5 port-vlan-id
Function
The port-vlan-id command allows assigning a port to explicitly belong to a VLAN and configure the VLAN as a group of ports.
However, when a frame with VLAN tags is received, the VLAN tag information has precedent over the port VID.
This command sets the default port VID (PVID) of the switch port. Also, the command registers it as a VLAN member port
(without a tag).
Use the no form to return to the default value.
Prompt
xg(config-if)# or xg(config-agg)#
Command syntax port-vlan-id vlan <1-4094> no port-vlan-id
Parameter
vlan <1-4094>
Specifies the default port VLAN ID (PVID). The PVID can be an integer of 1 to 4094.
Command type
Configuration command
Default
1
Message
% VLAN %1$ not configured. %2$
Explanation
The specified VLAN was not created.
[[Inserted string]]%1$: VID
[[Inserted string]]%2$: Port number
Solution
Create the VLAN first then reissue the command.
Note
When this command is issued, the port is registered as a member of the specified VLAN (having no tag). The frame having no tag is sent during egressing. To change the rule during egressing to “transfer tagged frames,” issue “vlan-member allowed vlan
<1-4094> egress-tagging”.
Example
Set the default PVID of switch ports 2 and assign it to “vlan-floor2”, VID=3.
Then, display the VLAN information using the “show vlan” command and make sure that VID 3 was registered with port 2 as a member (untagged frames during egressing). xg(config)# interface port 2 xg(config-if)# port-vlan-id vlan 3 xg(config-if)# exit xg(config)# exit xg# show vlan
Vlan Information 2007/01/22-16:20:15
==================================================================================
VID Vlan-Description Tag Ports-Membership
---- ------------------- ----- ----------------------------------------------------
1 default UNTAG port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
20
2 vlan-floor1 --- None
3 vlan-floor2 UNTAG port 2
==================================================================================
154/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.11.6 vlan-member allowed
Function
Registers a port as a VLAN member.
Use the no form to release the VLAN membership.
Prompt
xg(config-if)# or xg(config-agg)#
Command syntax vlan-member allowed vlan { <1-4094> | all } { egress-untagging | egress-tagging } no vlan-member allowed vlan { <1-4094> | all }
Parameter
vlan <1-4094>
Specifies a VLAN ID (or VID) for membership registration or VLAN ID deletion. The VID can be an integer of 1 to 4094. vlan all
Registers or deletes member ports for all registered VLANs. egress-untagging
Deletes a VLAN tag during frame transmission. egress-tagging
Adds a VLAN tag during frame transmission.
Command type
Configuration command
Default
Registers all ports with “egress-untagging” (the default VLAN).
Not set (except for the default VLAN)
Message
% VLAN %1$ not configured. %2$
Explanation
The specified VLAN was not created.
[[Inserted string]]%1$: VID
[[Inserted string]]%2$: Port number
Solution
Create a VLAN first then reissue the command.
% Can't remove vlan from port. Same pvid entry. %1$
Explanation
The specified VID cannot be deleted because it is identical to the default PVID.
[[Inserted string]]%1$: Port number
Solution
Change the default PVID and reissue the command.
Example
Enter the interface edit mode for ports 1 to 3 and register the ports as VLAN members (with tags) of VID 3.
Then, use the “show vlan” command to display the VLAN information. Check that ports 1 to 3 have been registered as members of the VLAN (VID 3). xg(config)# interface port range 1 3 xg(config-if)# vlan-member allowed vlan 3 egress-tagging xg(config-if)# exit xg(config)# exit xg# show vlan
Vlan Information 2007/01/22-16:20:15
==================================================================================
VID Vlan-Description Tag Ports-Membership
---- ------------------- ----- ----------------------------------------------------
1 default UNTAG port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
20
2 vlan-floor1 --- None
3 vlan-floor2 TAG port 1 2 3
==================================================================================
155/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.11.7 user-vlan-protocol-id
Function
The VLAN tag protocol ID (VPID or TPID) used for VLAN tag identification can be changed to the user-defined value of each port.
The standard VLAN tag protocol ID was defined as 0x8100 in IEEE 802.1Q. However, the standard IEEE 802.1Q tag for multiple-tag VLAN encapsulated with the user-defined VPID (or TPID) tag (*) can be used.
*: Similar functions are called Stacked VLAN, Nested VLAN, VLAN tunneling and 802.1Q in 802.1Q (Q-in-Q).
For the frame format, see the TPID (Tag Protocol Identifier) in "
For the multiple-tag VLAN setup example and the frame flow, see "
Prompt
xg(config-if)# or xg(config-agg)#
Command syntax user-vlan-protocol-id <0x05DD ~ 0xFFFF> no user-vlan-protocol-id
Parameter
user-vlan-protocol-id <0x05DD ~ 0xFFFF>
Specify the VPID (or TPID) using a hexadecimal integer beginning with 0x. It can be an integer in the range of 0x05DD to 0xFFFF.
Command type
Configuration command
Default
0x8100
Example
Enter the interface edit mode for ports 1 to 3 and set the VPID (or TPID) to 0x2000. xg(config)# interface port range 1 3 xg(config-if)# user-vlan-protocol-id 0x2000
5.11.8 ingress-filter no-vlan-member-frame
Function
Enables VLAN ingress filtering. If the VLAN ingress filter is enabled, frames from non-member ports of a VLAN are discarded.
Use the no form to disable the ingress filtering.
Prompt
xg(config-if)# or xg(config-agg)#
Command syntax ingress-filter no-vlan-member-frame no ingress-filter no-vlan-member-frame
Parameter
no-vlan-member-frame
Discards frames from non-member ports of a VLAN.
Command type
Configuration command
Default
None
Example
Enter the Edit Interface mode for switch ports 1 to 3 and enable VLAN ingress filtering. xg(config)# interface port range 1 3 xg(config-if)# ingress-filter no-vlan-member-frame
156/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.11.9 ingress-filter tagged-frame
Function
Specifies that designated port VLAN-tagged frames will be discarded.
Use the no form to disable frame discarding.
Prompt
xg(config-if)# or xg(config-agg)#
Command syntax ingress-filter tagged-frame no ingress-filter tagged-frame
Parameter
tagged-frame
Discards VLAN-tagged frames when they are received.
Command type
Configuration command
Default
None
Note
If the user VPID is specified by the “user-vlan-protocol-id,” a tag having the same tag ID as the user VPID is considered to be the VLAN tag.
If both “ingress-filter tagged-frame” and “ingress-filter untagged-frame” are specified, all frames received at this switch port are discarded.
Example
Enter the interface edit mode for ports 1 to 3 and specify to discard VLAN-tagged frames. xg(config)# interface port range 1 3 xg(config-if)# ingress-filter tagged-frame
5.11.10 ingress-filter untagged-frame
Function
Specifies that designated port VLAN untagged frames will be discarded.
Use the no form to disable frame discarding.
Prompt
xg(config-if)# or xg(config-agg)#
Command syntax ingress-filter untagged-frame no ingress-filter untagged-frame
Parameter
untagged-frame
Discards VLAN untagged frames when they are received.
Command type
Configuration command
Default
None
Note
If the user VPID is specified by the “user-vlan-protocol-id,” a tag having the same tag ID as the user VPID is considered to be the VLAN tag.
If both “ingress-filter tagged-frame” and “ingress-filter untagged-frame” are specified, all frames received at this port are discarded.
When using the Spanning Tree Protocol (STP), do not specify the “ingress-filter untagged-frame” command.
Example
Enter the interface edit mode for ports 1 to 3 and specify to discard VLAN untagged frames. xg(config)# interface port range 1 3 xg(config-if)# ingress-filter untagged-frame
157/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.11.11 vlan-statistics collection
Function
Configures the specified VLANs to collect statistics information. Up to 32 VLANs can be set.
Use the no form to cancel collecting the VLAN statistics information.
Prompt
xg(config)#
Command syntax vlan-statistics collection <1-4094> [ <1-4094> ] no vlan-statistics
Parameter
collection <1-4094> <1-4094>
Specifies the ID of the VLAN to collect statistics information.
To collect the statistics information on multiple VLANs, specify multiple VIDs by separating them with a “ ” (space). Up to 32 VLANs can be specified.
Command type
Configuration command
Default
None
Message
% Can't set vlan id. Over max entry number. [%1$]
Explanation
No more VLANs can be specified for collection. The maximum allowed VLANs (32) have been specified.
[[Inserted string]]%1$: Limit value
Solution
Delete VLANs whose information is no longer required then reissue the command.
Note
If a VID of an uncreated VLAN is specified, the command is terminated normally. However, the statistics information of an uncreated VLAN is not collected.
Example
Specify VIDs 1, 10, 20, 30 and 40 for VLAN statistics collection.
Then, change the VIDs to 1, 10, 20 and 30 only to collect their VLAN statistics information. xg(config)# vlan-statistics collection 1 10 20 30 40 xg(config)# vlan-statistics collection 1 10 20 30
158/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.12 QoS Setup Commands
This section explains the Quality of Service (QoS) configuration commands.
5.12.1 show qos
Function
Displays the current Quality of Service (QoS) status.
Prompt
xg> or xg#
Command syntax show qos [ qos-map ]
Parameter
qos-map
Displays the QoS priority mapping information (that is, the output queue information for each priority).
There are four levels of output queues (levels 0 to 3). A higher value has the higher output priority.
If this parameter is omitted, all QoS information is displayed.
Command type
Operation management command
Output form
xg# show qos
QoS Information 2007/01/22-12:12:15
===============================================================================
Priority Output Queue Mapping
-----------------------------------------
Qos Priority: 0 1 2 3 4 5 6 7
----------------- -- -- -- -- -- -- -- --
Output Priority: 1 0 0 1 2 2 3 3
-----------------------------------------
==============================================================================
QoS Priority Mapping Information
Qos Priority
Displays the QoS priority (0 to 7).
Output Priority
Displays the output queue level for each priority (0 to 3).
Example
Display the QoS status: xg# show qos
159/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.12.2 qos default-priority
Function
Sets the default priority for frames having no priority information (such as VLAN untagged frames).
Use the no form to return to the default setup.
Prompt
xg(config-if)# or xg(config-agg)#
Command syntax qos default-priority <0-7> no qos default-priority
Parameter
default-priority <0-7>
Sets the default priority for frames having no priority information.
Command type
Configuration command
Default
0
Example
Enter the interface edit mode for switch ports 1 and 3, and set the default priority to 1. xg(config)# interface port 1 3 xg(config-if)# qos default-priority 1
5.12.3 qos-map priority
Function
The system has four priority levels of output queues for frame transmission processing.
This command maps the frame priorities to the output queue levels.
Use the no form to reset the entire mapping information to the default setup.
Prompt
xg(config)#
Command syntax qos-map priority <0-7> output-priority <0-3> no qos-map
Parameter
priority <0-7>
Specifies a frame priority within the range of 0 to 7. output-priority <0-3>
Specifies the output queue level to be associated with the specified priority within the range of 0 to 3.
Command type
Configuration command
Default priority output-priority
0 1
1 0
2 0
3 1
4 2
5 2
6 3
7 3
Example
Map the priority “0” to the output queue “2”. xg(config)# qos-map priority 0 output-priority 2
160/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.12.4 bridge diffserv-tos
Function
Enables Quality of Service using the DiffServ code point.
When priority control by DiffServ codes is enabled, any priority included in a VLAN tag and the default priority are ignored.
Use the no form to disable DiffServ code control.
Prompt
xg(config)#
Command syntax bridge diffserv-tos { ipv4 | ipv6 } no bridge diffserv-tos
Parameter
diffserv-tos { ipv4 | ipv6 }
Enables Quality of Service using the DiffServ code point.
− ipv4
Enables IPv4 Quality of Service.
− ipv6
Enables IPv6 Quality of Service.
Command type
Configuration command
Default
None
Example
Enable Quality of Service using the DiffServ code point for IPv4. xg(config)# bridge enable-diffserv-tos ipv4
161/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.12.5 qos egress-scheduling
Function
Sets the egress scheduling algorithm.
Use the no form to reset to default.
Prompt
xg(config-if)# or xg(config-agg)#
Command syntax qos egress-scheduling {strict | drr | drr-strict} no qos egress-scheduling
Parameter
egress-scheduling
Specify the egress scheduling algorithm
− strict
Frames are forwarded based on strict priority scheduling. Higher priority frames always precede those of lower priority.
− drr
Frames are forwarded based on deficit round robin (DRR) algorithm. Minimum bandwidth for each output queue can be specified by "qos bandwidth" command.
− Drr-strict
Frames are forwarded based on the combination of strict priority scheduling and DRR algorithm. Strict priority scheduling is used for output queue "0" and "1", and DRR algorithm for output queue "2" and "3".
Command type
Configuration command
Default
Strict
Example
Sets strict method to the algorithm that schedules priority. xg(config-if)# qos egress-scheduling strict
162/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.12.6 qos bandwidth
Function
Sets a band width value for an output queue. Each output queue can be assured sufficient output traffic rate.
Use the no form to reset to default.
Prompt
xg(config-if)# or xg(config-agg)#
Command syntax qos bandwidth <0-10000> output-priority <0-3> no qos bandwidth
Parameter
bandwidth <0-10000>
Specifies the bandwidth of an output queue in the range of 0 to 10000 Mbps. The value must be an integer divisible by 100. output-priority <0-3>
Specifies the output queue within the range of 0 to 3 to associate with the bandwidth value.
Command type
Configuration command
Default
0 (Sets the band width of the output queue to be equal)
Message
% The set value is not step of 100
Explanation
The specified the band width value is not an integer divisible by 100.
Solution
Sets a band width value with an integer divisible by 100.
% The total value exceeded 10000
Explanation
The sum of the bandwidth values of each output queue is exceeds 10Gbps.
Solution
Changes the bandwidth values so the total does not exceed 10Gbps.
Note
Residual bandwidth is assigned to each output queue without specified bandwidth. Enabling jumbo frames and the frame size established affects minimum bandwidth assignments across all output queues. The "The total value exceeded 10000" error message may be displayed despite the fact the total bandwidth assigned a given queue does not exceed 10Gbps.
Setting bandwidth 0 is same as no form, so the configuration is cleared.
Example
Sets 4Gbps for output queue "0" s. xg(config-if)# no qos bandwidth xg(config-if)# qos bandwidth 4000 output-priority 0
163/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.13 Port Mirroring Setup Commands
This section explains the configuration commands for port mirroring.
5.13.1 show mirror
Function
Displays the current mirroring configuration for send and receive frames.
Prompt
xg> or xg#
Command syntax show mirror
Command type
Operation management command
Output form
xg# show mirror
Mirror Information 2007/01/22-12:12:15
===============================================================================
Monitored Port Rx Mirroring Port
-------------- -----------------
Port-1 ===> Port-2
Monitored Port Tx Mirroring Port
-------------- -----------------
Port-1 ===> Port-3
===============================================================================
Monitored Port
Displays the port number of the monitored switch.
Rx Mirroring Port
Displays the destination port number for mirroring of frames received at the monitored port.
Tx Mirroring Port
Displays the destination port number for mirroring of frames sent from the monitored port.
Example
Display the port mirroring status. xg> show mirror
164/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.13.2 mirror
Function
Configures port mirroring for specific ports.
Use the no form to cancel the port mirroring setup.
Prompt
xg(config)#
Command syntax mirror monitored-port <1-20> [rx-mirroring-port <1-20>] [tx-mirroring-port <1-20>] no mirror
Parameter
monitored-port <1-20>
Specifies a port number to be monitored. rx-mirroring-port <1-20>
Specifies the destination port number for mirroring of received frames. It must be different from the port specified by “monitored-port/tx-mirroring-port”. tx-mirroring-port <1-20>
Specifies the destination port number for mirroring of sent frames. It must be different from the port specified by “monitored-port/rx-mirroring-port”.
Command type
Configuration command
Default
None
Message
% Cannot set same port.
Explanation
Identical port numbers for the “monitored-port”, “rx-mirroring-port” or
“tx-mirroring-port” have been specified.
Solution
Specify different port numbers by reviewing the “monitored-port”, “rx-mirroring-port” and “tx-mirroring-port” values then reissue the command.
Note
If port mirroring was enabled before issuing this command, the impacted ports are reassigned in accordance with the most recent command.
Example
Mirror the frames received at port 1 to port 2, and mirror the frames sent from port 1 to port 3. xg(config)# mirror monitored-port 1 rx-mirroring-port 2 tx-mirroring-port 3
Mirror the frames received at port 1 to port 2. xg(config)# mirror monitored-port 1 rx-mirroring-port 2
165/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.14 IGMP Snooping Setup Commands
This section explains the IGMP snooping configuration commands.
5.14.1 show ip snooping
Function
Displays the IGMP snooping configuration.
Prompt
xg> or xg#
Command syntax show ip snooping [vlan <1-4094> ] show ip snooping mrouter [vlan <1-4094>] show ip snooping group [vlan <1-4094>]
Parameter
[vlan <1-4094>]
Displays the IGMP snooping configuration for the specified VLAN.
If this parameter is omitted, all of the VLANs configuration information is displayed. mrouter [vlan <1-4094>]
Displays only the multicast router information for the IGMP snooping configuration.
If "vlan" is omitted, all of the VLANs’ configuration information is displayed. group [vlan <1-4094>]
Displays only the registered multicast group information for the IGMP snooping configuration.
If "vlan" is omitted, all of the VLANs’ configuration information is displayed.
Command type
Operation management command
Output form
xg# show ip snooping
IGMP Snooping Information 2007/01/22-22:17:04
===============================================================================
Global IGMP snooping : { Enabled | Disabled }
[vlan-1]
IGMP snooping : { Enabled | Disabled }
Registered group number : 0 (Current) / 32 (Maximum)
Multicast router auto learning: { Enabled | Disabled }
Fast leave : { Enabled | Disabled }
Group Membership interval : 260 (sec)
Last Member Query interval : 2 (sec)
Send Query count : 2 (times)
IGMP snooping querier : { Enabled | Disabled }
General Query interval : 125 (sec)
Querier IP address : 0.0.0.0
Multicast Router Information
----------------------------------------------------------------------------
Vlan Type Mrouter ports
---- ------- -------------
1 static port 5
----------------------------------------------------------------------------
Multicast Group Information
----------------------------------------------------------------------------
Vlan Multicast Group Ver Member ports
---- --------------- --- ---------------------------------------------------
1 225.10.10.1 2 port 1 5
------------------------------------------------------------------------------
[vlan-2]
Global IGMP snooping
The operational state of IGMP snooping for the device is displayed.
− Enabled
IGMP snooping is enabled.
− Disabled
IGMP snooping is disabled.
166/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
[vlan 1]
The VIDs of applicable VLANs are displayed.
IGMP snooping
The IGMP operational state for the applicable VLANs are displayed.
− Enabled
IGMP snooping is enabled.
− Disabled
IGMP snooping is disabled.
Registered group number
The number of registered multicast groups detected through IGMP snooping are displayed.
− (Current)
The number of currently registered groups is displayed.
− (Maximum)
The maximum number of groups that can be registered for the applicable VLANs is displayed.
Multicast router auto learning
The status of the Automatic Learning mode for the multicast router is displayed.
− Enabled
Automatic learning for the multicast router is enabled.
− Disabled
Automatic learning for the multicast router is disabled.
Fast leave
The status of the Immediate Leave mode is displayed.
− Enabled
The Immediate Leave mode is enabled.
− Disabled
The Immediate Leave mode is disabled.
Group Membership interval
The valid interval time (in seconds) for the registered multicast group is displayed.
Last Member Query interval
The monitoring time (in seconds) for leaving confirmation when an IGMP Leave message is received is displayed.
Send Query count
The transmission frequency of query messages by the IGMP query function is displayed.
IGMP snooping querier
The operation state of IGMP query function is displayed.
− Enabled
The IGMP query function is enabled.
− Disabled
The IGMP query function is disabled.
General Query interval
The transmission interval (in seconds) of query messages sent by the IGMP query function is displayed.
Querier IP address
Source IP address of the query message sent by the IP querier is displayed.
Multicast Router Information
The multicast router status is displayed.
Vlan
The ID of the applicable VLAN is displayed.
Type
The identified type of multicast router is displayed.
− static
This is a multicast router statically set by the CLI.
− dynamic
This is a multicast router port dynamically learned by IGMP snooping.
Mrouter ports
The port numbers registered with the multicast router are displayed.
For an aggregation group, the group number is displayed immediately after the “agg-port” information.
Multicast Group Information
The state of the registered multicast groups detected through IGMP snooping are displayed.
Vlan
The ID of the applicable VLAN is displayed.
Multicast Group
The addresses of registered IP multicast groups are displayed.
Ver
The version of the received IGMP protocol is displayed.
Member ports
The port numbers of the registered multicast group is displayed.
For an aggregation group, the group number is displayed immediately after the “agg-port” information.
167/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Output form (if “mrouter” is specified)
Only the multicast router information is extracted from the IGMP snooping information and displayed. xg# show ip snooping mrouter
IGMP Snooping Information(Multicast Router) 2005/04/24-22:19:52
===============================================================================
Vlan Type Mrouter ports
---- ------- -------------
1 static port 5
2 dynamic port 6
----------------------------------------------------------------------------
===============================================================================
Output form (if “group” is specified)
Only the multicast group information is extracted from the IGMP snooping information and displayed. xg# show ip snooping group
IGMP Snooping Information(Multicast Group) 2005/04/24-22:20:56
===============================================================================
Vlan Multicast Group Ver Member ports
---- --------------- --- ---------------------------------------------------
1 225.0.0.1 2 port 1 5
2 225.0.0.2 2 port 1 5
----------------------------------------------------------------------------
===============================================================================
5.14.2 ip snooping protocol
Function
Enables global IGMP snooping.
Use the no form to disable the snooping.
Prompt
xg(config)#
Command syntax ip snooping protocol igmp no ip snooping protocol igmp
Parameter
protocol igmp
Enables global IGMP snooping for the device.
Command type
Configuration command
Default
None
Message
% port %1$ is membership of uplink-domain %2$.
Explanation
The displayed port is used as an uplink.
[[Inserted string]]%1$: Port number
[[Inserted string]]%2$: Uplink domain number
Solution
Clear the uplink domain before enabling IGMP snooping.
Note
IGMP snooping and the uplink filter function cannot be used at the same time.
Example
Enable IGMP snooping of the device. xg(config)# ip snooping protocol igmp
168/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.14.3 ip snooping vlan
Function
Enables IGMP snooping for a specified VLAN.
IGMP snooping can be enabled for each VLAN only after enabling global IGMP snooping using the “ip snooping protocol” command.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax ip snooping vlan <1-4094> no ip snooping vlan <1-4094>
Parameter
vlan <1-4094>
Enables IGMP snooping for the specified VLAN.
Command type
Configuration command
Default
Enabled (for the default VLAN)
Disabled (for all VLANs other than the default VLAN)
Message
% Global IGMP snooping is not enabled.
Explanation
Global IGMP snooping on the device is disabled.
Solution
Enable global IGMP snooping using the “ip snooping protocol” command first then reissue the “ip snooping vlan” command.
% Vlan id is not found. vid=%1$
Explanation
The specified VLAN was not created.
[[Inserted string]]%1$: VID of the specified VLAN
Solution
Create a VLAN using the “vlan” command first then reissue the “ip snooping vlan” command.
% More than 128 total max-group per system.
Explanation
The registration number of multicast addresses allowed on the entire system exceeded the limit (128 addresses).
Solution
Reduce the maximum number of VLANs using the “ip snooping vlan max-group” command, or disable the IGMP snooping function for other VLANs.
Example
Enable IGMP snooping of VLAN 2: xg(config)# ip snooping vlan 2
169/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.14.4 ip snooping vlan max-group
Function
Defines the number of multicast groups that can be registered for IGMP snooping on each VLAN.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax ip snooping vlan <1-4094> max-group <10-128> no ip snooping vlan <1-4094> max-group
Parameter
vlan <1-4094>
Changes the IGMP snooping setup for the specified VLAN. max-group <10-128>
Sets the maximum number of multicast groups that can be registered. It can be any integer between 10 and 128.
Command type
Configuration command
Default
32
Message
% Global IGMP snooping is not enabled.
Explanation
Global IGMP snooping on the device is disabled.
Solution
Enable global IGMP snooping using the “ip snooping protocol” command first, then reissue the “ip snooping vlan” command.
% Vlan id is not found. vid=%1$
Explanation
The specified VLAN was not created.
[[Inserted string]]%1$: VID of the specified VLAN
Solution
Create a VLAN using the “vlan” command first then reissue the “ip snooping vlan” command.
% IGMP snooping vlan-%1$ is not enabled.
Explanation
IGMP snooping for the specified VLAN is disabled.
[[Inserted string]]%1$: VID of the specified VID
Solution
Enable the IGMP snooping for the VLAN using the “ip snooping vlan” command first then reissue the “ip snooping vlan max-group” command.
% More than 128 total max-group per system.
Explanation
The registrated number of multicast addresses allowed on the entire system exceeded the limit (128 addresses).
Solution
Reduce the maximum number of VLANs using the “ip snooping vlan max-group” command, or disable the IGMP snooping function for other VLANs.
Note
Up to 128 multicast MAC addresses can be registered on the entire system.
Therefore, if IGMP snooping is used by multiple VLANs, care must be taken not to exceed the limit number of multicast
MAC addresses.
Sets the maximum number of multicast groups not to exceed the number of multicast groups that Is registered currently.
Example
Set the number of groups that can be registered for IGMP snooping on VLAN 2 to 50. xg(config)# ip snooping vlan 2 max-group 50
170/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.14.5 ip snooping vlan mrouter
Function
Automatically learns the IGMP query message receiving port as a multicast router port.
This command can statically set multicast router ports. Also, it can change the automatic learning mode of multicast router ports.
Set multicast router ports statically to register more than one multicast router port.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax ip snooping vlan <1-4094> mrouter { port <1-20> | agg-port <1-10> } no ip snooping vlan <1-4094> mrouter { port <1-20> | agg-port <1-10> } ip snooping vlan <1-4094> mrouter suppress-learning no ip snooping vlan <1-4094> mrouter suppress-learning
Parameter
vlan <1-4094>
Specifies the VLAN to change. mrouter port <1-20>
Specifies a port number to be set statically as the multicast router port. mrouter agg-port <1-10>
Specifies an aggregation group number to be set statically as the multicast router port. mrouter suppress-learning
Disables automatic learning on the multicast router ports.
Command type
Configuration command
Default
None
Message
% Global IGMP snooping is not enabled.
Explanation
Global IGMP snooping on the device is disabled.
Solution
Enable global IGMP snooping using the “ip snooping protocol” command first then reissue the “ip snooping vlan” command.
% Vlan id is not found. vid=%1$
Explanation
The specified VLAN was not created.
[[Inserted string]]%1$: Specified VID
Solution
Create a VLAN using the “vlan” command first then reissue the “ip snooping vlan” command.
% IGMP snooping vlan-%1$ is not enabled.
Explanation
IGMP snooping of the specified VLAN is disabled.
[[Inserted string]]%1$: Specified VID
Solution
Enable IGMP snooping on the VLAN using the “ip snooping vlan” command first, then reissue the “ip snooping vlan max-group” command.
% Port is not vlan member. vid=%1$
Explanation
The specified port is not a VLAN member.
[[Inserted string]]%1$: Specified VID
Solution
Set the port as a VLAN member using the “vlan-member allowed” command first, then reissue the “ip snooping vlan mrouter” command.
% Aggregation-port is not vlan member. vid=%1$
Explanation
The specified aggregation group is not a VLAN member.
[[Inserted string]]%1$: Specified VLAN ID
Solution
Set the aggregation group as a VLAN member using the “vlan-member allowed” command first, then reissue the “ip snooping vlan mrouter” command.
% Aggregation-port not bound to bridge.
Explanation
The specified aggregation group does not exist.
Solution
Configure a link aggregation group by using the “link-aggregation” command first then specify the “agg-port” using the “ip snooping vlan mrouter” command.
171/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
% Can't set mrouter on a port which belongs to an aggregation port.
Explanation
A port belonging to a link aggregation group cannot be specified as an mrouter port.
Solution
Review the specified port number and reissue the command. When registering an aggregation group specify “agg-port”.
% Multicast router port %1$ could not be deleted
Explanation
The specified port is not set to be an multicast router port.
[[Inserted string]]%1$: Specified port number
Solution
Review multicast router information and execute the command again.
Example
Set aggregation group 1 as a multicast router port: xg(config)# ip snooping vlan 2 mrouter agg-port 1
5.14.6 ip snooping vlan group-member-interval
Function
Sets a valid time interval (in seconds) for the IP multicast group which was registered for IGMP snooping.
The registered IP multicast group is deleted if an IGMP Report message is not received within the valid time.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax ip snooping vlan <1-4094> group-member-interval <60-600> no ip snooping vlan <1-4094> group-member-interval
Parameter
vlan <1-4094>
Specifies a VLAN to change. group-member-interval <60-600>
Specifies the valid time period in seconds for the registered IP multicast group.
It is recommended "group member interval" be set by considering the message transmission interval of the multicast router connected to the system. (This interval is called the "query interval" and its default is 125 seconds in RFC.) The recommended value is as follows.
Group-member-interval = Query Interval 2 + 10 (seconds)
Command type
Configuration command
Default
260 seconds
Message
% Global IGMP snooping is not enabled.
Explanation
Global IGMP snooping on the device is disabled.
Solution
Enable global IGMP snooping using the “ip snooping protocol” command first then reissue the “ip snooping vlan group-member-interval” command.
% Vlan id is not found. vid=%1$
Explanation
The specified VLAN was not created.
[[Inserted string]]%1$: Specified VID
Solution
Create a VLAN using the “vlan” command first then reissue the “ip snooping vlan group-member-interval” command.
% IGMP snooping vlan-%1$ is not enabled.
Explanation
IGMP snooping on the specified VLAN is disabled.
[[Inserted string]]%1$: Specified VID
Solution
Enable IGMP snooping on the VLAN using the “ip snooping vlan” command first, then reissue the “ip snooping vlan group-member-interval” command.
Example
Set the valid time interval for the IP multicast group learned at VLAN 1 to 300 seconds (5 minutes). xg(config)# ip snooping vlan 1 group-member-interval 300
172/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.14.7 ip snooping vlan fast-leave
Function
Set the Fast Leave mode on the IP multicast group port where the IGMP Leave message is received. In the Fast Leave mode, the exit is not checked when the IGMP Leave message is received.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax ip snooping vlan <1-4094> fast-leave no ip snooping vlan <1-4094> fast-leave
Parameter
vlan <1-4094>
Specifies a VLAN to change. fast-leave
Enables the Fast Leave mode.
Command type
Configuration command
Default
None
Message
% Global IGMP snooping is not enabled.
Explanation
Global IGMP snooping on the device is disabled.
Solution
Enable global IGMP snooping using the “ip snooping protocol” command first then reissue the “ip snooping vlan fast-leave” command.
% Vlan id is not found. vid=%1$
Explanation
The specified VLAN was not created.
[[Inserted string]]%1$: Specified VID
Solution
Create a VLAN using the “vlan” command first then reissue the “ip snooping vlan fast-leave” command.
% IGMP snooping vlan-%1$ is not enabled.
Explanation
IGMP snooping of the specified VLAN is disabled.
[[Inserted string]]%1$: Specified VID
Solution
Enable IGMP snooping on the VLAN using the “ip snooping vlan” command first then reissue the “ip snooping vlan fast-leave” command.
Example
Enable the Fast Leave mode on VLAN 1. xg(config)# ip snooping vlan 1 fast-leave
173/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.14.8 ip snooping vlan last-member-query-interval
Function
Sets the monitoring time (in seconds) for checking on the exit of the last member of a IP multicast group. If an IGMP Report message is not issued within the monitoring time after reception of an IGMP Leave message, the IP multicast group is deleted.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax ip snooping vlan <1-4094> last-member-query-interval <1-9> no ip snooping vlan <1-4094> last-member-query-interval
Parameter
vlan <1-4094>
Specifies a VLAN to change. last-member-query-interval <1-9>
Specifies the monitoring time (in seconds) to check for member exit.
Command type
Configuration command
Default
2 seconds
Message
% Global IGMP snooping is not enabled.
Explanation
Global IGMP snooping on the device is disabled.
Solution
Enable global IGMP snooping using the “ip snooping protocol” command first then reissue the “ip snooping vlan last-member-query-interval” command.
% Vlan id is not found. vid=%1$
Explanation
The specified VLAN was not created.
[[Inserted string]]%1$: Specified VID
Solution
Create a VLAN using the “vlan” command first then reissue the “ip snooping vlan” command.
% IGMP snooping vlan-%1$ is not enabled.
Explanation
IGMP snooping of the specified VLAN is disabled.
[[Inserted string]]%1$: Specified VID
Solution
Enable IGMP snooping on the VLAN using the “ip snooping vlan” command first, then reissue the “ip snooping vlan last-member-query-interval” command.
Example
Set the monitoring time to check for member exit on VLAN 2 to 3 seconds. xg(config)# ip snooping vlan 2 last-member-query-interval 3
174/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.14.9 ip snooping vlan send-query-count
Function
Sets a query message transmission frequency.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax ip snooping vlan <1-4094> send-query-count <1-3> no ip snooping vlan <1-4094> send-query-count
Parameter
vlan <1-4094>
Specifies a VLAN to change. send-query-count <1-3>
Sets a query message transmission frequency.
Command type
Configuration command
Default
2
Message
% Global IGMP snooping is not enabled.
Explanation
Global IGMP snooping on the device is disabled.
Solution
Enable global IGMP snooping using the “ip snooping protocol” command first then reissue the “ip snooping vlan send-query-count” command.
% Vlan id is not found. vid=%1$
Explanation
The specified VLAN was not created.
[[Inserted string]]%1$: Specified VID
Solution
Create a VLAN using the “vlan” command first then reissue the “ip snooping vlan send-query-count” command.
% IGMP snooping vlan-%1$ is not enabled.
Explanation
IGMP snooping of the specified VLAN is disabled.
[[Inserted string]]%1$: Specified VID
Solution
Enable IGMP snooping on the VLAN using the “ip snooping vlan” command first, then reissue the “ip snooping vlan send-query-count” command.
Example
Set the query message transmission frequency on VLAN 2 to 3: xg(config)# ip snooping vlan 2 send-query-count 3
175/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.14.10 ip snooping vlan querier
Function
The IGMP Querier function sends an IGMP General Query message to each terminal node instead of the multicast router if no multicast router exists on the network segment.
This command enables the IGMP querier. The query message transmission interval (called “Query interval”) is calculated based on the query message transmission frequency and the group valid time interval (called “Group member interval”) as follows.
Query interval = (Group-membership-interval – 10) / send-query-count (seconds)
The device does not send Query messages when there is a multicast router on the network.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax ip snooping vlan <1-4094> querier ip A.B.C.D no ip snooping vlan <1-4094> querier
Parameter
vlan <1-4094>
Specifies a VLAN to change. querier
Enables the IGMP querier function. ip A.B.C.D
Specifies the source IP address of Query messages to be sent by the IGMP querier.
The IP address can be 0.0.0.0 or within the range of 1.0.0.1 to 126.255.255.254, 128.0.0.1 to 191.255.255.254, or 192.0.0.1 to 223.255.255.254.
Command type
Configuration command
Default
None
Message
% Global IGMP snooping is not enabled.
Explanation
Global IGMP snooping is disabled on the system.
Solution
Enable global IGMP snooping using the “ip snooping protocol” command first then reissue the “ip snooping vlan querier” command.
% Vlan id is not found. vid=%1$
Explanation
The specified VLAN was not created.
[[Inserted string]]%1$: Specified VLAN ID
Solution
Create a VLAN using the “vlan” command first then reissue the “ip snooping vlan querier” command.
% IGMP snooping vlan-%1$ is not enabled.
Explanation
IGMP snooping on the specified VLAN is disabled.
[[Inserted string]]%1$: Specified VID
Solution
Enable IGMP snooping on the VLAN using the “ip snooping vlan” command first, then reissue the “ip snooping vlan querier” command.
% Invalid IP-address.
Explanation
The IP address was specified in an incorrect format or an incorrect address was specified.
Solution
Specify the IP address in the correct format and reissue the command.
Example
Enable an IGMP querier on VLAN 1 and set the query transmission source IP address to "192.168.1.200.” xg(config)# ip snooping vlan 1 querier ip 192.168.1.200
176/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.14.11 ip snoop
Function
Enables IGMP snooping for specified VLANs. This command is enabled after enabling global IGMP snooping using the “ip snooping protocol” command.
Use the no form to return to the default setup.
Prompt
xg(config-vlan)#
Command syntax ip snooping no ip snooping
Command type
Configuration command
Default
Enabled (for the default VLAN)
Disabled (for all VLANs other than the default VLAN)
Message
% Global IGMP snooping is not enabled.
Explanation
Global IGMP snooping on the device is disabled.
Solution
Enable global IGMP snooping using the “ip snooping protocol” command first then execute the command again.
% More than 128 total max-group per system.
Explanation
The registered number of multicast addresses allowed on the entire system exceeded the limit (128 addresses).
Solution
Reduce the maximum number of VLANs using a command such as “ip snooping vlan max-group”, or disable the IGMP snooping function for other VLANs.
Example
Enable IGMP snooping of VLAN 2 and 3. xg(config)# interface vlan 2 3 xg(config-vlan)# ip snooping
177/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.14.12 ip snooping max-group
Function
Defines the number of multicast groups that can be registered for IGMP snooping on specified VLANs.
Use the no form to return to the default setup.
Prompt
xg(config-vlan)#
Command syntax max-group <10-128>
no ip snooping max-group
Parameter
max-group <10-128>
Sets the maximum number of multicast groups that can be registered. It can be any integer between 10 and 128.
Command type
Configuration command
Default
32
Message
% Global IGMP snooping is not enabled.
Explanation
Global IGMP snooping on the device is disabled.
Solution
Enable global IGMP snooping using the “ip snooping protocol” command first then execute the command again.
% More than 128 total max-group per system.
Explanation
The registered number of multicast addresses allowed on the entire system exceeded the limit (128 addresses).
Solution
Reduce the maximum number of VLANs using a command such as “ip snooping vlan max-group”, or disable the IGMP snooping function for other VLANs.
Note
Up to 128 multicast MAC addresses can be registered on the entire system.
Therefore, if IGMP snooping is used by multiple VLANs, care must be taken not to exceed the limit number of multicast
MAC addresses.
Sets the maximum number of multicast groups not to exceed the number of multicast groups that Is registered currently.
Example
Set the number of groups, that can be registered for IGMP snooping on VLAN 2 and 3, to 30. xg(config)# interface vlan 2 3 xg(config-vlan)# ip snooping max-group 30
178/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.14.13 ip snooping mrouter
Function
Automatically learns the IGMP query message receiving port as a multicast router port.
This command can statically set multicast router ports. Also, it can change the automatic learning mode of multicast router ports.
Set multicast router ports statically to register more than one multicast router port.
Use the no form to return to the default setup.
Prompt
xg(config-vlan)#
Command syntax ip snooping mrouter { port <1-20> | agg-port <1-10> } no ip snooping mrouter { port <1-20> | agg-port <1-10> } ip snooping mrouter suppress-learning
no ip snooping mrouter suppress-learning
Parameter
mrouter port <1-20>
Specifies a port number to be set statically as the multicast router port. mrouter agg-port <1-10>
Specifies an aggregation group number to be set statically as the multicast router port. mrouter suppress-learning
Disables automatic learning on the multicast router ports.
Command type
Configuration command
Default
None
Message
% Global IGMP snooping is not enabled.
Explanation
Global IGMP snooping on the device is disabled.
Solution
Enable global IGMP snooping using the “ip snooping protocol” command first then execute the command again.
% IGMP snooping vlan-%1$ is not enabled.
Explanation
IGMP snooping of the specified VLAN is disabled.
[[Inserted string]]%1$: Specified VID
Solution
Enable IGMP snooping on the VLAN using the “ip snooping vlan” command first, then execute the command again.
% Port is not vlan member. vid=%1$
Explanation
The specified port is not a VLAN member.
[[Inserted string]]%1$: Specified VID
Solution
Set the port as a VLAN member using the “vlan-member allowed” command first, then execute the command again.
% Aggregation-port is not vlan member. vid=%1$
Explanation
The specified aggregation group is not a VLAN member.
[[Inserted string]]%1$: Specified VLAN ID
Solution
Set the aggregation group as a VLAN member using the “vlan-member allowed” command first, then execute the command again.
% Aggregation-port not bound to bridge.
Explanation
The specified aggregation group does not exist.
Solution
Configure a link aggregation group by using the “link-aggregation” command first then execute the command again.
179/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
% Can't set mrouter on a port which belongs to an aggregation port.
Explanation
A port belonging to a link aggregation group cannot be specified as an mrouter port.
Solution
Review the specified port number and reissue the command. When registering an aggregation group specify “agg-port”.
% Multicast router port %1$ could not be deleted
Explanation
The specified port is not set to be an multicast router port.
[[Inserted string]]%1$: Specified port number
Solution
Review multicast router information and execute the command again.
Example
Set port 1 as a multicast router port at VLAN 2 and 3 xg(config)# interface vlan 2 3 xg(config-vlan)# ip snooping mrouter port 1
5.14.14 ip snooping group-member-interval
Function
Sets a valid time interval (in seconds) for the IP multicast group which was registered for IGMP snooping.
The registered IP multicast group is deleted if an IGMP Report message is not received within the valid time.
Use the no form to return to the default setup.
Prompt
xg(config-vlan)#
Command syntax ip snooping group-member-interval <60-600>
no ip snooping group-member-interval
Parameter
group-member-interval <60-600>
Specifies the valid time period in seconds for the registered IP multicast group.
It is recommended "group member interval" be set by considering the message transmission interval of the multicast router connected to the system. (This interval is called the "query interval" and its default is 125 seconds in RFC.) The recommended value is as follows.
Group-member-interval = Query Interval 2 + 10 (seconds)
Command type
Configuration command
Default
260 seconds
Message
% Global IGMP snooping is not enabled.
Explanation
Global IGMP snooping on the device is disabled.
Solution
Enable global IGMP snooping using the “ip snooping protocol” command first then execute the command again.
% IGMP snooping vlan-%1$ is not enabled.
Explanation
IGMP snooping on the specified VLAN is disabled.
[[Inserted string]]%1$: Specified VID
Solution
Enable IGMP snooping on the VLAN using the “ip snooping vlan” command first, then execute the command again.
Example
Set the valid time interval for the IP multicast group learned at VLAN 2 and 3 to 300 seconds (5 minutes). xg(config)# interface vlan 2 3 xg(config-vlan)# ip snooping group-member-interval 300
180/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.14.15 ip snooping fast-leave
Function
Set the Fast Leave mode on the IP multicast group port where the IGMP Leave message is received. In the Fast Leave mode, the exit is not checked when the IGMP Leave message is received.
Use the no form to return to the default setup.
Prompt
xg(config-vlan)#
Command syntax ip snooping fast-leave
no ip snooping fast-leave
Parameter
fast-leave
Enables the Fast Leave mode.
Command type
Configuration command
Default
None
Message
% Global IGMP snooping is not enabled.
Explanation
Global IGMP snooping on the device is disabled.
Solution
Enable global IGMP snooping using the “ip snooping protocol” command first then execute the command again.
% IGMP snooping vlan-%1$ is not enabled.
Explanation
IGMP snooping of the specified VLAN is disabled.
[[Inserted string]]%1$: Specified VID
Solution
Enable IGMP snooping on the VLAN using the “ip snooping vlan” command first then execute the command again.
Example
Enable the Fast Leave mode on VLAN 2 and 3. xg(config)# interface vlan 2 3 xg(config-vlan)# ip snooping fast-leave
181/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.14.16 ip snooping last-member-interval
Function
Sets the monitoring time (in seconds) for checking on the exit of the last member of a IP multicast group. If an IGMP Report message is not issued within the monitoring time after reception of an IGMP Leave message, the IP multicast group is deleted.
Use the no form to return to the default setup.
Prompt
xg(config-vlan)#
Command syntax ip snooping last-member-interval <1-9>
no ip snooping last-member-interval
Parameter
last-member-interval <1-9>
Specifies the monitoring time (in seconds) to check for member exit.
Command type
Configuration command
Default
2 seconds
Message
% Global IGMP snooping is not enabled.
Explanation
Global IGMP snooping on the device is disabled.
Solution
Enable global IGMP snooping using the “ip snooping protocol” command first then execute the command again.
% IGMP snooping vlan-%1$ is not enabled.
Explanation
IGMP snooping of the specified VLAN is disabled.
[[Inserted string]]%1$: Specified VID
Solution
Enable IGMP snooping on the VLAN using the “ip snooping vlan” command first, then execute the command again.
Example
Set the monitoring time to check for member exit on VLAN 2 to 3 seconds. xg(config)# interface vlan 2 xg(config-vlan)# ip snooping last-member-interval 3
182/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.14.17 ip snooping send-query-count
Function
Sets a query message transmission frequency.
Use the no form to return to the default setup.
Prompt
xg(config-vlan)#
Command syntax ip snooping send-query-count <1-3>
no ip snooping send-query-count
Parameter
send-query-count <1-3>
Sets a query message transmission frequency.
Command type
Configuration command
Default
2
Message
% Global IGMP snooping is not enabled.
Explanation
Global IGMP snooping on the device is disabled.
Solution
Enable global IGMP snooping using the “ip snooping protocol” command first then execute the command again.
% IGMP snooping vlan-%1$ is not enabled.
Explanation
IGMP snooping of the specified VLAN is disabled.
[[Inserted string]]%1$: Specified VID
Solution
Enable IGMP snooping on the VLAN using the “ip snooping vlan” command first, then execute the command again.
Example
Set the query message transmission frequency on VLAN 2 to 3: xg(config)# interface vlan 2 xg(config-vlan)# ip snooping send-query-count 3
183/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.14.18 ip snooping querier
Function
The IGMP Querier function sends an IGMP General Query message to each terminal node instead of the multicast router if no multicast router exists on the network segment.
This command enables the IGMP querier. The query message transmission interval (called “Query interval”) is calculated based on the query message transmission frequency and the group valid time interval (called “Group member interval”) as follows.
Query interval = (Group-membership-interval – 10) / send-query-count (seconds)
The device does not send Query messages when there is a multicast router on the network.
Use the no form to return to the default setup.
Prompt
xg(config-vlan)#
Command syntax ip snooping querier ip A.B.C.D
no ip snooping querier
Parameter
querier
Enables the IGMP querier function. ip A.B.C.D
Specifies the source IP address of Query messages to be sent by the IGMP querier.
The IP address can be 0.0.0.0 or within the range of 1.0.0.1 to 126.255.255.254, 128.0.0.1 to 191.255.255.254, or 192.0.0.1 to 223.255.255.254.
Command type
Configuration command
Default
None
Message
% Global IGMP snooping is not enabled.
Explanation
Global IGMP snooping is disabled on the system.
Solution
Enable global IGMP snooping using the “ip snooping protocol” command first then execute the command again.
% IGMP snooping vlan-%1$ is not enabled.
Explanation
IGMP snooping on the specified VLAN is disabled.
[[Inserted string]]%1$: Specified VID
Solution
Enable IGMP snooping on the VLAN using the “ip snooping vlan” command first, then execute the command again.
% Invalid IP-address.
Explanation
The IP address was specified in an incorrect format or an incorrect address was specified.
Solution
Specify the IP address in the correct format and execute the command.
Example
Enable an IGMP querier on VLAN 2 and set the query transmission source IP address to "192.168.1.200.” xg(config)# interface vlan 2 xg(config-vlan)# ip snooping querier ip 192.168.1.200
184/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15 Statistics Commands
The device provides a wide variety of statistical displays.
Statistics can be displayed using the “monitor” command, which periodically updates the display information, or by using the
“show statistics” command which displays a snapshot.
The transmission byte statistics information does not include preambles (framing bytes).
Set the terminal screen size to 50 columns by 12 lines or more when issuing the “monitor” command.
If the terminal screen size is too small, the following message is displayed.
% terminal line is too small
or
% terminal width is too short
The number of statistics display lines vary depending upon the counter used.
If the line length exceeds the limit, the following unit is displayed at the right of the displayed value. The unit indicates a multiplier for the value displayed.
K: 1,000
M: 1,000,000
G: 1,000,000,000
T: 1,000,000,000,000
185/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15.1 monitor traffic-bytes
Function
Displays the transmission frame length (in bytes) at each port.
Prompt
xg> or xg#
Command syntax monitor traffic-bytes { current | total } [interval <3-60>]
Parameter
{ current | total }
Specifies the statistics to be displayed.
− current
Displays the accumulated byte count of transmission frames after startup of this command.
− total
Displays the accumulated byte count of transmission frames after startup of the system. interval <3-60>
Specifies the update interval (in seconds).
The default interval is 3 seconds.
Command type
Operation management command
Output form (if "current" is specified)
xg# monitor traffic-bytes current
Traffic Statistics(Current Frame Bytes) 2007/01/22-12:12:15
====================================================================>
Port Link State/ Tx Rate Rx Rate Tx-Frame Rx-Frame
STP State Bits/Sec Bits/Sec Bytes Bytes
---- ------------- ---------- ---------- ------------ -----------
1 Up/Discard 12345678K 12345678K 1234567890K 1234567890K
2 Down 0 0 0 0
3 Up/Discard 923 923 1234567890K 1234567890K
4 Up/Learn 999123K 999123K 1234567890M 1234567890M
5 Up/Forward 999 999 1234567890G 1234567890G
6 Up/Forward 999999K 999999K 1234567890T 1234567890T
7 Down 0 0 0 0
8 Down 0 0 0 0
===================================================================>
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
(continues)
Traffic Statistics(Current Frame Bytes) 2007/01/22-12:12:15
<======================================================================
Port-Description
------------------------------------ port_name1 port_name2 port_name3 port_name4 port_name5 port_name6 port_name7
<======================================================================
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
Port
Displays port numbers. Statistics for each port are displayed on one line.
Link State/STP State
Displays the port state in the Link State or STP State format.
The Link State may indicate one of the following link states.
− Down
The port link is down.
− Up
The port link is up.
The STP State displays the current port status based on the STP (Spanning Tree Protocol).
Note that the STP State is not displayed if the Link State is down.
For port status details, see “Spanning Tree Protocol Port States".
Tx Rate Bits/Sec
Displays the transmission rate (in bps) using an 8-digit, right-justified value.
Rx Rate Bits/Sec
Displays the receive rate (in bps) using an 8-digit, right-justified value.
Tx-Frame Bytes
Displays the accumulated transmission byte count after execution of this command, using a
10-digit, right-justified value.
Rx-Frame Bytes
Displays the accumulated receive byte count after execution of this command, using a 10-digit, right-justified value.
186/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Port-Description
Displays port descriptions. If the port is not described, it will not display anything.
Up to 33 characters can be displayed.
Output form (if "total" is specified)
xg# monitor traffic-bytes total
Traffic Statistics(Total Frame Bytes) 2007/01/22-12:12:15
==============================================================================
Port Link State/ Tx-Frame Rx-Frame Port-Description
STP State Bytes Bytes
---- ------------- ----------- ------------ ---------------------------------
1 Up/Discard 1234567890K 1234567890K port_name1
2 Down 1234567890G 1234567890G port_name2
3 Up/Discard 1234567890M 1234567890M port_name3
4 Up/Learn 1234567890T 1234567890T port_name4
5 Up/Forward 1234567890 1234567890 port_name5
6 Up/Forward 1234567890 1234567890 port_name6
7 Down 1234567890 1234567890 port_name7
8 Down 1234567890 1234567890
==============================================================================
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
Port
Same as the display description for the “current” option
Link State/STP State
Same as the display description for the “current” option
Tx-Frame Bytes
Displays the accumulated transmission byte count after system startup, using a 10-digit, right-justified value.
Rx-Frame Bytes
Displays the accumulated receive byte count after system startup, using a 10-digit, right-justified value.
Port-Description
Same as the display description for the “current” option
187/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15.2 monitor traffic-counts
Function
Displays the transmission frame count at each port.
Prompt
xg> or xg#
Command syntax monitor traffic-counts { current | total } [interval <3-60>]
Parameter
{ current | total }
Specifies the statistics to be displayed.
− current
Displays the number of accumulated transmission frames after startup of this command.
− total
Displays the number of accumulated transmission frames after startup of the system. interval <3-60>
Specifies the update interval (in seconds).
The default interval is 3 seconds.
Command type
Operation management command
Output form (if "current" is specified)
xg# monitor traffic-counts current
Traffic Statistics(Current Frame Counts) 2007/01/22-12:12:15
===============================================================================>
Port Link State/ Tx-Frame Rx-Frame Tx-Frame Rx-Frame Rx-Bcast
STP State Counts/S Counts/S Counts Counts Counts
---- ---------- ---------- ---------- ---------- ------------ -----------
1 Up/Discard 12345678K 12345678K 1234567890K 1234567890K 1234567890K
2 Down 0 0 0 0 0
3 Up/Discard 923 923 1234567890K 1234567890K 1234567890K
4 Up/Learn 999123 999123 1234567890M 256M 256M
5 Up/Forward 999 999 1234567890G 256G 256G
6 Up/Forward 999999 999999 1234567890T 256T 256T
===============================================================================>
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
(continues)
Traffic Statistics(Current Frame Counts) 2007/01/22-12:12:15
<=================================================================================
Rx-Mcast Port-Description
Counts
----------- ------------------------------------
1234567890K port_name1
0 port_name2
1234567890K port_name3
256M port_name4
256G port_name5
256T
<=================================================================================
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
Port
Displays the port numbers. Statistics for each port are displayed on one line.
Link State/STP State
Displays the port state in the Link State or STP State format.
The Link State may indicate one of the following link states.
− Down
The port link is down.
− Up
The port link is up.
The STP State displays the current port status based on the STP (Spanning Tree Protocol).
Note that the STP State is not displayed if the Link State is down.
For port status details, see “
Spanning Tree Protocol Port States ”.
Tx-Frame Counts/S
Displays the transmission frame rate (in fps) using an 8-digit, right-justified value.
Rx-Frame Counts/S
Displays the receive frame rate (in fps) using an 8-digit, right-justified value.
Tx-Frame Counts
Displays the number of accumulated transmission frames after execution of this command, using a 10-digit, right-justified value.
Rx-Frame Counts
Displays the number of accumulated receive frames after execution of this command, using a 10-digit, right-justified value.
Rx-Bcast Counts
Displays the number of accumulated receive broadcast frames after execution of this command,
188/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide using a 10-digit, right-justified value.
Rx-Mcast Counts
Displays the number of accumulated receive multicast frames after execution of this command, using a 10-digit, right-justified value.
Port-Description
Displays port descriptions. If the port is not described, it will not display anything.
Up to 36 characters can be displayed.
Output form (if “total” is specified)
xg# monitor traffic-counts total
Traffic Statistics(Total Frame Counts) 2007/01/22-12:12:15
=======================================================================>
Port Link State/ Tx-Frames Rx-Frames Rx-Bcast Rx-Mcast
STP State Counts Counts Counts Counts
---- ------------ ----------- ----------- ----------- -----------
1 Up/Discard 1234567890K 1234567890K 1234567890K 1234567890K
2 Down 0 0 0 0
3 Up/Discard 1234567890K 1234567890K 1234567890K 1234567890K
4 Up/Learn 1234567890K 1234567890K 1234567890K 1234567890K
5 Up/Forward 1234567890K 1234567890K 1234567890K 1234567890K
6 Up/Forward 1234567890K 1234567890K 1234567890K 1234567890K
7 Down 1234567890K 1234567890K 1234567890K 1234567890K
8 Down 1234567890K 1234567890K 1234567890K 1234567890K
======================================================================>
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
(continues)
Traffic Statistics(Total Frame Counts) 2007/01/22-12:12:15
<======================================================================
Port-Description
------------------------------------ port_name1 port_name2 port_name3 port_name4 port_name5 port_name6 port_name7
<======================================================================
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
Port
Same as the display described for the “current” option
Link State/STP State
Same as the display described for the “current” option
Tx-Frame Counts
Displays the number of accumulated transmission frames after system startup, using a 10-digit, right-justified value.
Rx-Frame Counts
Displays the number of accumulated receive frames after system startup, using a 10-digit, right-justified value.
Rx-Bcast Counts
Displays the number of accumulated receive broadcast frames after system startup, using a
10-digit, right-justified value.
Rx-Mcast Counts
Displays the number of accumulated receive multicast frames after system startup, using a
10-digit, right-justified value.
Port-Description
Same as the display description for the “current” option
189/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15.3 monitor framesize-traffic-counts
Function
Displays a frame count and size range for frames which have been sent or received at each port.
Prompt
xg> or xg#
Command syntax monitor framesize-traffic-counts { current | total } [interval <3-60>]
Parameter
{ current | total }
Specifies the statistics to be displayed.
− current
Displays the number of accumulated frames after startup of this command.
− total
Displays the number of accumulated frames after startup of the system. interval <3-60>
Specifies the update interval (in seconds).
The default interval is 3 seconds.
Command type
Operation management command
Output form (if "current" is specified)
xg# monitor framesize-traffic-counts current
Framesize Traffic Statistics(Current Frame Counts) 2007/01/22-12:12:15
===============================================================================>
Port Link State/ FrameSize FrameSize FrameSize FrameSize FrameSize
STP State 0-64 65-127 128-255 256-511 512-1023
---- --------- ---------- ---------- ----------- ----------- -----------
1 Up/Discard 1234567890K 1234567890K 1234567890K 1234567890K 1234567890K
2 Down 0 0 0 0 0
3 Up/Discard 1234567890K 1234567890K 1234567890K 1234567890K 1234567890K
4 Up/Learn 1234567890M 25690M 25690M 25690M 25690M
5 Up/Forward 1234567890G 25690G 25690G 25690G 25690G
6 Up/Forward 1234567890T 25690T 25690T 25690T 25690T
7 Down 0 0 0 0 0
8 Down 0 0 0 0 0
===============================================================================>
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
(continues)
Framesize Traffic Statistics(Current Frame Counts) 2007/01/22-12:12:15
<==========================================================================
FrameSize Port-Description
1024-1518
----------- --------------------------------------------
1234567890K port_name1
0 port_name2
1234567890K port_name3
25690 port_name4
25690G port_name5
25690T port_name6
0 port_name7
0
<==========================================================================
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
Port
Displays the port numbers. Statistics for each port are displayed on one line.
Link State/STP State
Displays the port state in the Link State or STP State format.
The Link State may indicate one of the following link states.
− Down
The port link is down.
− Up
The port link is up.
The STP State displays the current port status based on the STP (Spanning Tree Protocol).
Note that the STP State is not displayed if the Link State is down.
For port status details, see “
Spanning Tree Protocol Port States .”
FrameSize 0-64
Displays the number of accumulated 64-byte frames sent or received after the command execution.
FrameSize 65-127
Displays the number of accumulated 65- to 127-byte frames sent or received after the command execution.
FrameSize 128-255
Displays the number of accumulated 128- to 255-byte frames sent or received after the command execution.
FrameSize 256-511
Displays the number of accumulated 256- to 511-byte frames sent or received after the command
190/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide execution.
FrameSize 512-1023
Displays the number of accumulated 512- to 1023-byte frames sent or received after the command execution.
FrameSize 1024-1518
Displays the number of accumulated 1024- to 1518-byte frames sent or received after the command execution.
Port-Description
Displays port descriptions. If the port is not described, it will not display anything.
Up to 44 characters can be displayed.
Output form (if "total" is specified)
xg# monitor framesize-traffic-counts total
Framesize Traffic Statistics(Total Frame Counts) 2007/01/22-12:12:15
=============================================================================>
Port Link State/ FrameSize FrameSize FrameSize FrameSize Framesize
STP State 0-64 65-127 128-255 256-511 512-1023
---- ----------- ----------- ----------- ----------- ----------- -----------
1 Up/Discard 1234567890K 1234567890K 1234567890K 1234567890K 1234567890K
2 Down 0 0 0 0 0
3 Up/Discard 1234567890K 1234567890K 1234567890K 1234567890K 1234567890K
4 Up/Learn 1234567890M 25690M 25690M 25690M 25690M
5 Up/Forward 1234567890G 25690G 25690G 25690G 25690G
6 Up/Forward 1234567890T 25690T 25690T 25690T 25690T
7 Down 0 0 0 0 0
8 Down 0 0 0 0 0
=============================================================================>
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
(continues)
Framesize Traffic Statistics(Total Frame Counts) 2007/01/22-12:12:15
<==========================================================================
FrameSize Port-Description
1024-1518
----------- --------------------------------------------
1234567890K port_name1
0 port_name2
1234567890K port_name3
25690 port_name4
25690G port_name5
25690T port_name6
0 port_name7
0
<==========================================================================
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
The displayed values are the ones accumulated after the system startup. Other values are the same as those displayed if the “current” option were specified.
191/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15.4 monitor qos-priority-traffic-bytes
Function
Displays the number of bytes received at each port for each QoS priority.
Prompt
xg> or xg#
Command syntax monitor qos-priority-traffic-bytes { current | total } [interval <3-60>]
Parameter
{ current | total }
Specifies the statistics to be displayed.
− current
Displays the number of bytes in each QoS priority received after startup of this command.
− total
Displays the number of bytes in each QoS priority received after the system startup. interval <3-60>
Specifies the update interval (in seconds).
The default interval is 3 seconds.
Command type
Operation management command
Output form (if "current" is specified)
xg# monitor qos-priority-traffic-bytes current
Qos Priority Traffic Statistics(Current Frame Bytes) 2007/01/22-12:12:15
===================================================================================>
Port Priority-0 Priority-1 Priority-2 Priority-3 Priority-4 Priority-5 Priority-6
Bytes Bytes Bytes Bytes Bytes Bytes Bytes
---- ----------- ----------- ----------- ----------- ----------- ----------- -----------
1 1234567890K 1234567890K 1234567890 1234567890 1234567890 1234567890 1234567890
2 0 0 0 0 0 0 0
3 1234567890K 1234567890K 1234567890K 1234567890K 1234567890K 1234567890K 1234567890K
4 1234567890M 256890M 256890M 256890M 256890M 256890M 256890M
5 1234567890G 256890G 256890G 256890G 256890G 256890G 256890G
6 1234567890T 256890T 256890T 256890T 256890T 256890T 256890T
7 0 0 0 0 0 0 0
8 0 0 0 0 0 0 0
===================================================================================>
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
(continues)
Qos Priority Traffic Statistics(Current Frame Bytes) 2007/01/22-12:12:15
<================================================================================
Priority-7 Port-Description
Bytes
----------- ---------------------------------------------------
1234567890 port_name1
0 port_name2
1234567890K port_name3
256890M port_name4
256890G port_name5
256890T port_name6
0 port_name7
0
<================================================================================
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
Port
Displays the port numbers. Statistics for each port are displayed on one line.
Priority-0 Bytes - Priority-7 Bytes
Display the accumulated number of bytes for each of priority 0 through 7 received at each port after the command execution, using 10-digit, right-justified values.
Port-Description
Displays port descriptions. If the port is not described, it will not display anything.
Up to 51 characters can be displayed.
192/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Output form (if "total" is specified)
xg# monitor qos-priority-traffic-bytes total
Qos Priority Traffic Statistics(Total Frame Bytes) 2007/01/22-12:12:15
===================================================================================>
Port Priority-0 Priority-1 Priority-2 Priority-3 Priority-4 Priority-5 Priority-6
Bytes Bytes Bytes Bytes Bytes Bytes Bytes
---- ----------- ----------- ----------- ----------- ----------- ----------- -----------
1 1234567890K 1234567890K 1234567890 1234567890 1234567890 1234567890 1234567890
2 0 0 0 0 0 0 0
3 1234567890K 1234567890K 1234567890K 1234567890K 1234567890K 1234567890K 1234567890K
4 1234567890M 256890M 256890M 256890M 256890M 256890M 256890M
5 1234567890G 256890G 256890G 256890G 256890G 256890G 256890G
6 1234567890T 256890T 256890T 256890T 256890T 256890T 256890T
7 0 0 0 0 0 0 0
8 0 0 0 0 0 0 0
===================================================================================>
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
(continues)
Qos Priority Traffic Statistics(Total Frame Bytes) 2007/01/22-12:12:15
<================================================================================
Priority-7 Port-Description
Bytes
----------- ---------------------------------------------------
1234567890 port_name1
0 port_name2
1234567890K port_name3
256890M port_name4
256890G port_name5
256890T port_name6
0 port_name7
0
<================================================================================
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
The bytes displayed in the “Bytes” column are the ones accumulated after the system startup. Other values are the same as those displayed if the “current” option were specified.
193/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15.5 monitor qos-priority-traffic-counts
Function
Displays the number of frames received at each port for each QoS priority.
Prompt
xg> or xg#
Command syntax monitor qos-priority-traffic-counts { current | total } [interval <3-60>]
Parameter
{ current | total }
Specifies the statistics to be displayed.
− current
Displays the accumulated number of frames in each QoS priority received after startup of this command.
− total
Displays the accumulated number of frames in each QoS priority received after the system startup. interval <3-60>
Specifies the update interval (in seconds).
The default interval is 3 seconds.
Command type
Operation management command
Output form (if "current" is specified)
xg# monitor qos-priority-traffic-counts current
Qos Priority Traffic Statistics(Current Frame Counts) 2007/01/22-12:12:15
===================================================================================>
Port Priority-0 Priority-1 Priority-2 Priority-3 Priority-4 Priority-5 Priority-6
Counts Counts Counts Counts Counts Counts Counts
---- ----------- ----------- ----------- ----------- ----------- ----------- -----------
1 1234567890K 1234567890K 1234567890 1234567890 1234567890 1234567890 1234567890
2 0 0 0 0 0 0 0
3 1234567890K 1234567890K 1234567890K 1234567890K 1234567890K 1234567890K 1234567890K
4 1234567890M 256890M 256890M 256890M 256890M 256890M 256890M
5 1234567890G 256890G 256890G 256890G 256890G 256890G 256890G
6 1234567890T 256890T 256890T 256890T 256890T 256890T 256890T
7 0 0 0 0 0 0 0
8 0 0 0 0 0 0 0
===================================================================================>
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
(continues)
Qos Priority Traffic Statistics(Current Frame Counts) 2007/01/22-12:12:15
<==============================================================================
Priority-7 Port-Description
Counts
----------- ---------------------------------------------------
1234567890 port_name1
0 port_name2
1234567890K port_name3
256890M port_name4
256890G port_name5
256890T port_name6
0 port_name7
0
<==============================================================================
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
Port
Displays the port numbers. Statistics for each port are displayed on one line.
Priority-0 Counts to Priority-7 Counts
Display the accumulated number of frames for each priority 0 through 7 received at each port after the command execution, using 10-digit, right-justified values.
Port-Description
Displays port descriptions. If the port is not described, it will not display anything.
Up to 51 characters can be displayed.
194/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Output form (if "total" is specified)
xg# monitor qos-priority-traffic-counts total
Qos Priority Traffic Statistics(Total Frame Counts) 2007/01/22-12:12:15
===================================================================================>
Port Priority-0 Priority-1 Priority-2 Priority-3 Priority-4 Priority-5 Priority-6
Counts Counts Counts Counts Counts Counts Counts
---- ----------- ----------- ----------- ----------- ----------- ----------- -----------
1 1234567890K 1234567890K 1234567890 1234567890 1234567890 1234567890 1234567890
2 0 0 0 0 0 0 0
3 1234567890K 1234567890K 1234567890K 1234567890K 1234567890K 1234567890K 1234567890K
4 1234567890M 256890M 256890M 256890M 256890M 256890M 256890M
5 1234567890G 256890G 256890G 256890G 256890G 256890G 256890G
6 1234567890T 256890T 256890T 256890T 256890T 256890T 256890T
7 0 0 0 0 0 0 0
8 0 0 0 0 0 0 0
===================================================================================>
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
(continues)
Qos Priority Traffic Statistics(Total Frame Counts) 2007/01/22-12:12:15
<==========================================================================
Priority-7 Port-Description
Counts
----------- ---------------------------------------------------
1234567890 port_name1
0 port_name2
1234567890K port_name3
256890M port_name4
256890G port_name5
256890T port_name6
0 port_name7
0
<==========================================================================
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
The values displayed in the “Counts” column are the ones accumulated after the system startup. Other values are the same as those displayed if the “current” option were specified.
195/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15.6 monitor vlan-traffic-bytes
Function
Displays the received byte count of each VLAN.
Prompt
xg> or xg#
Command syntax monitor vlan-traffic-bytes { current | total } [interval <3-60>]
Parameter
{ current | total }
Specifies the statistics to be displayed.
− current
Displays the accumulated byte count of received frames for each VLAN after startup of this command.
− total
Displays the accumulated byte count of received frames for each VLAN after the system startup. interval <3-60>
Specifies the update interval (in seconds).
The default interval is 3 seconds.
Command type
Operation management command
Output form (if "current" is specified)
xg# monitor vlan-traffic-bytes current
VLAN Traffic Statistics(Current Frame Bytes) 2007/01/22-12:12:15
================================================================
VID Rx-Frame Rx-NonUcast
Bytes Bytes
---- ----------- ------------
1 1234567890 1234567890
10 0 0
20 1234567890K 1234567889K
30 25690M 25690M
40 25690G 25690G
4094 0 0
================================================================
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
VID
Displays the VID of the VLAN set for statistics collection. Statistics of each VLAN are displayed on one line.
Specify the VLAN to collect its statistics using the "vlan-statistics collection" command.
Rx-Frame Bytes
Displays the accumulated byte count of frames received at the specified VLAN after the startup of this command, using a 10-digit, right-justified value.
Rx-NonUcast Bytes
Displays the accumulated byte count of multicast or broadcast frames received at the specified
VLAN after the startup of this command, using a 10-digit, right-justified value.
Output form (if "total" is specified)
xg# monitor qos-priority-traffic-bytes total
VLAN Traffic Statistics(Total Frame Bytes) 2007/01/22-12:12:15
==============================================================
VID Rx-Frame Rx-NonUcast
Bytes Bytes
---- ----------- ------------
1 1234567890 1234567890
10 0 0
20 1234567890K 1234567889K
30 25690M 25690M
40 25690G 25690G
4094 0 0
==============================================================
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
The bytes displayed in the “Bytes” column are the ones accumulated after the system startup. Other values are the same as those displayed if the “current” option were specified.
196/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15.7 monitor vlan-traffic-counts
Function
Displays the received frame count of each VLAN.
Prompt
xg> or xg#
Command syntax monitor vlan-traffic-counts { current | total } [interval <3-60>]
Parameter
{ current | total }
Specifies the statistics to be displayed.
− current
Displays the accumulated number of frames for each VLAN received after startup of this command.
− total
Displays the accumulated number of frames for each VLAN received after the system startup. interval <3-60>
Specifies the update interval (in seconds).
The default interval is 3 seconds.
Command type
Operation management command
Output form (if "current" is specified)
xg# monitor vlan-traffic-counts current
VLAN Traffic Statistics(Current Frame Counts) 2007/01/22-12:12:15
=================================================================
VID Rx-Frame Rx-NonUcast
Counts Counts
---- ----------- -----------
1 1234567890 1234567890
10 0 0
20 1234567890K 1234567890K
30 25690M 25690M
40 25690G 25690G
4094 0 0
=================================================================
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
VID
Displays the VID of the VLAN set for statistics collection. Statistics for each VLAN are displayed on one line.
Specify the VLAN to collect its statistics using the "vlan-statistics collection" command.
Rx-Frame Counts
Displays the accumulated number of frames received at the specified VLAN after the startup of this command, using a 10-digit, right-justified value.
Rx-NonUcast Counts
Displays the accumulated number of multicast or broadcast frames received at the specified
VLAN after the startup of this command, using a 10-digit, right-justified value.
Output form (if "total" is specified)
xg# monitor vlan-traffic-counts total
VLAN Traffic Statistics(Total Frame Counts) 2007/01/22-12:12:15
===============================================================
VID Rx-Frame Rx-NonUcast
Counts Counts
---- ----------- -----------
1 1234567890 1234567890
10 0 0
20 1234567890K 1234567890K
30 25690M 25690M
40 25690G 25690G
4094 0 0
===============================================================
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
The values displayed in the “Counts” column are the ones accumulated after the system startup. Other values are the same as those displayed if the “current” option were specified.
197/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15.8 monitor dataflow
Function
Displays statistics including both pause frame transmission to and from each port and the results of transmission processing.
Prompt
xg> or xg#
Command syntax monitor dataflow { current | total } [interval <3-60>]
Parameter
{ current | total }
Specifies the statistics to be displayed.
− current
Displays the accumulated data count after startup of this command.
− total
Displays the accumulated data count after the system startup. interval <3-60>
Specifies the update interval (in seconds).
The default interval is 3 seconds.
Command type
Operation management command
Output form (if "current" is specified)
xg# monitor dataflow current
Dataflow Statistics(Current Counts) 2007/01/22-12:12:15
======================================================================>
Port Link State/ Flow-Ctl Forward Flood Rx-Pause Tx-Pause
STP State Mode Counts Counts Counts Counts
---- ------------- ------- ----------- ----------- ----------- -----------
1 Up/Discard Rx & Tx 1234567890 1234567890 1234567890 1234567890
2 Down Rx 0 0 0 0
3 Up/Discard Rx & Tx 1234567890K 1234567890K 1234567890K 1234567890K
4 Up/Learn Rx & Tx 1234567890M 25690M 25690M 25690M
5 Up/Forward Rx & Tx 1234567890G 25690G 25690G 25690G
6 Up/Forward Rx & Tx 1234567890T 25690T 25690T 25690T
7 Down Rx 0 0 0 0
8 Down Rx 0 0 0 0
======================================================================>
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
(continues)
Dataflow Statistics(Current Counts) 2007/01/22-12:12:15
<======================================================================
Full-Drop VLAN-Drop Port-Description
Counts Counts
----------- ----------- -----------------------------
1234567890 1234567890 port_name1
0 0 port_name2
1234567890K 1234567890K port_name3
25690M 25690M port_name4
25690G 25690G port_name5
25690T 25690T port_name6
0 0 port_name7
0 0
<======================================================================
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
Port
Displays the port numbers. Statistics for each port are displayed on one line.
Link State/STP State
Displays the port state in the Link State or STP State format.
The Link State may indicate one of the following link states.
− Down
The port link is down.
− Up
The port link is up.
The STP State indicates the current port status based on the STP (Spanning Tree Protocol).
Note that the STP State is not displayed if the Link State is down.
For port status details, see “
Spanning Tree Protocol Port States ”.
Flow-Ctl Mode
Displays the flow control setup for each port.
− Rx & Tx
Both transmission and reception of pause frames are enabled.
− Rx
Only the reception of pause frames is enabled.
Forward Counts
Displays the accumulated number of frames forwarded normally (the unicast frames received at each port after the startup of this command).
Flood Counts
Displays the accumulated number of flooded frames among the unicast frames received at each
198/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide port after the startup of this command.
Rx-Pause Counts
Displays the accumulated number of pause frames received at each port after the startup of this command.
Tx-Pause Counts
Displays the accumulated number of pause frames sent from each port after the startup of this command.
Full-Drop Counts
Displays the number of frames discarded due to the saturated port input buffer of the system after startup of this command.
VLAN-Drop Counts
Displays the number of frames discarded due to the reception of non-VLAN member frames that are not allowed to be forwarded among those received at each port after the startup of this command.
Port-Description
Displays port descriptions. If the port is not described, it will not display anything.
Up to 29 characters can be displayed.
Output form (if "total" is specified)
xg# monitor dataflow total
Dataflow Statistics(Total Counts) 2007/01/22-12:12:15
=====================================================================>
Port Link State/ Flow-Ctl Forward Flood Rx-Pause Tx-Pause
STP State Mode Counts Counts Counts Counts
---- ----------- -------- ----------- ----------- ----------- -----------
1 Up/Discard Rx & Tx 1234567890 1234567890 1234567890 1234567890
2 Down Rx 0 0 0 0
3 Up/Discard Rx & Tx 1234567890K 1234567890K 1234567890K 1234567890K
4 Up/Learn Rx & Tx 1234567890M 25690M 25690M 25690M
5 Up/Forward Rx & Tx 1234567890G 25690G 25690G 25690G
6 Up/Forward Rx & Tx 1234567890T 25690T 25690T 25690T
7 Down Rx 0 0 0 0
8 Down Rx 0 0 0 0
=====================================================================>
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
(continues)
Dataflow Statistics(Total Counts) 2007/01/22-12:12:15
<======================================================
Full-Drop VLAN-Drop Port-Description
Counts Counts
----------- ----------- -----------------------------
1234567890 1234567890 port_name1
0 0 port_name2
1234567890K 1234567890K port_name3
25690M 25690M port_name4
25690G 25690G port_name5
25690T 25690T port_name6
0 0 port_name7
0 0
<======================================================
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
The values displayed in the “Counts” column are the ones accumulated after the system startup. Other values are the same as those displayed if the “current” option were specified.
199/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15.9 monitor error
Function
Displays error traffic statistics for each port.
Prompt
xg> or xg#
Command syntax monitor error { current | total } [interval <3-60>]
Parameter
{ current | total }
Specifies the statistics to be displayed.
− current
Displays the accumulated error count after startup of this command.
− total
Displays the accumulated error count after the system startup.
If the error count reaches 4294967295, it is returned to 0 when incremented. interval <3-60>
Specifies the update interval (in seconds).
The default interval is 3 seconds.
Command type
Operation management command
Output form (if "current" is specified)
xg# monitor error current
Error Statistics(Current Counts) 2007/01/22-12:12:15
==================================================================================>
Port Rx Rx & Tx Rx & Tx Rx & Tx Rx & Tx Rx Total
CRC Over Under Fragment Jabber Align Lost
--- ---------- ---------- ---------- ---------- ---------- ---------- ----------
1 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890
2 123 12 34 34 56 78 90
3 123 12 34 34 56 78 90
4 123 12 34 34 56 78 90
5 123 12 34 34 56 78 90
6 123 12 34 34 56 78 90
7 123 12 34 34 56 78 90
8 123 12 34 34 56 78 90
=================================================================================>
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
(continues)
Error Statistics(Current Counts) 2007/01/22-12:12:15
<======================================================================
Port-Description
------------------------------------ port_name1 port_name2 port_name3 port_name4 port_name5 port_name6 port_name7
<=======================================================================
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
Port
Displays the port numbers. Statistics for each port are displayed on one line.
Rx CRC
Displays the accumulated number of FCS (Frame Check Sequence) error frames received after startup of this command.
Rx & Tx Over
Displays the accumulated number of frames whose size exceeds 1518 bytes (excluding the VLAN tag) after startup of this command.
Rx & Tx Under
Displays the accumulated number of transmission frames whose size is less than 64 bytes after startup of this command.
Rx & Tx Fragment
Displays the accumulated number of FCS (Frame Check Sequence) error frames whose size is less than 64 bytes sent or received after startup of this command.
200/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Rx & Tx Jabber
Displays the accumulated number of FCS (Frame Check Sequence) error frames whose size exceeds
1518 bytes (excluding the VLAN tag) sent or received after startup of this command.
Rx Align
Displays the accumulated number of 64- to 1518-byte alignment error frames whose bit size is not a multiple of 8 received after startup of this command.
Total Lost
Displays the accumulated number of frames received but discarded at each port after startup of this command.
Port-Description
Displays port descriptions. If the port is not described, it will not display anything.
Up to 31 characters can be displayed.
Output form (if "total" is specified)
xg# monitor error total
Error Statistics(Total Counts) 2007/01/22-12:12:15
==================================================================================>
Port Rx Rx & Tx Rx & Tx Rx & Tx Rx & Tx Rx Total
CRC Over Under Fragment Jabber Align Lost
---- -------- --------- --------- --------- --------- --------- ----------
1 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890
2 123 12 34 34 56 78 90
3 123 12 34 34 56 78 90
4 123 12 34 34 56 78 90
5 123 12 34 34 56 78 90
6 123 12 34 34 56 78 90
7 123 12 34 34 56 78 90
8 123 12 34 34 56 78 90
==================================================================================>
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
(continues)
Error Statistics(Current Counts) 2007/01/22-12:12:15
<======================================================================
Port-Description
------------------------------------ port_name1 port_name2 port_name3 port_name4 port_name5 port_name6 port_name7
<=======================================================================
ESC:exit F:refresh
U:page up D:page down L:page left R:page right
The displayed values are the ones accumulated after the system startup. Other values are the same as those displayed if the
“current” option were specified.
201/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15.10 show statistics traffic-bytes
Function
Displays the accumulated number of bytes sent or received to and from each port after the system startup.
Prompt
xg> or xg#
Command syntax show statistics traffic-bytes
Command type
Operation management command
Output form
xg# show statistics traffic-bytes
Traffic Statistics(Total Frame Bytes) 2007/01/22-19:22:55
==========================================================
[No.1]
Port : 1
Link State/ STP State : Up/Forward
Tx-Frame Bytes : 71872
Rx-Frame Bytes : 63424
Port-Description : port_name1
[No.2]
[No. ]
Displays statistics for each port.
Port
Displays the port numbers.
Link State/STP State
Displays the port state in the Link State or STP State format.
The Link State may indicate one of the following link states.
− Down
The port link is down.
− Up
The port link is up.
The STP State displays the current port status based on the STP (Spanning Tree Protocol).
Note that the STP State is not displayed if the Link State is down.
For port status details, see “
Spanning Tree Protocol Port States ”.
Tx-Frame Bytes
Displays the accumulated number of bytes sent after the system startup.
Rx-Frame Bytes
Displays the accumulated number of bytes received after the system startup.
Port-Description
Displays port descriptions. If the port is not described, it will not display anything.
Up to 33 characters can be displayed.
202/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15.11 show statistics traffic-counts
Function
Displays the accumulated number of frames sent or received to and from each port after the system startup.
Prompt
xg> or xg#
Command syntax show statistics traffic-counts
Command type
Operation management command
Output form
xg# show statistics traffic-counts
Traffic Statistics(Total Frame Counts) 2007/01/22-19:41:39
=============================================================
[No.1]
Port : 1
Link State/ STP State: Up/Forward
Tx-Frame Counts : 367
Rx-Frame Counts : 300
Rx-Bcast Counts : 0
Rx-Mcast Counts : 300
Port-Description : port_name1
[No.2]
[No.]
Displays statistics for each port.
Port
Displays the port numbers.
Link State/STP State
Displays the port state in the Link State or STP State format.
The Link State may indicate one of the following link states.
− Down
The port link is down.
− Up
The port link is up.
The STP State displays the current port status based on the STP (Spanning Tree Protocol).
Note that the STP State is not displayed if the Link State is down.
For port status details, see “
Spanning Tree Protocol Port States ”.
Tx-Frame Counts
Displays the accumulated number of frames sent after the system startup.
Rx-Frame Counts
Displays the accumulated number of frames received after the system startup.
Rx-Bcast Counts
Displays the accumulated number of broadcast frames received after the system startup.
Rx-Mcast Counts
Displays the accumulated number of multicast frames received after the system startup.
Port-Description
Displays port descriptions. If the port is not described, it will not display anything.
Up to 36 characters can be displayed.
203/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15.12 show statistics framesize-traffic-counts
Function
Displays traffic statistics for each port in different frame size groups.
Prompt
xg> or xg#
Command syntax show statistics framesize-traffic-counts
Command type
Operation management command
Output form
xg# show statistics framesize-traffic-counts
Framesize Traffic Statistics(Total Frame Counts) 2007/01/22-19:44:11
=====================================================================
[No.1]
Port : 1
Link State/ STP State: Up/Forward
FrameSize 0-64 : 805
FrameSize 65-127 : 0
FrameSize 128-255 : 0
FrameSize 256-511 : 0
FrameSize 512-1023 : 0
FrameSize 1024-1518 : 0
Port-Description : port_name1
[No.2]
[No.]
Displays statistics for each port.
Port
Displays the port numbers.
Link State/STP State
Displays the port state in the Link State or STP State format.
The Link State may indicate one of the following link states.
− Down
The port link is down.
− Up
The port link is up.
The STP State displays the current port status based on the STP (Spanning Tree Protocol).
Note that the STP State is not displayed if the Link State is down.
For port status details, see “
Spanning Tree Protocol Port States ”.
FrameSize 0-64
Displays the accumulated number of 64-byte frames sent or received at each port after the system startup.
FrameSize 65-127
Displays the accumulated number of 65- to 127-byte frames sent or received at each port after the system startup.
FrameSize 128-255
Displays the accumulated number of 128- to 255-byte frames sent or received at each port after the system startup.
FrameSize 256-511
Displays the accumulated number of 256- to 511-byte frames sent or received at each port after the system startup.
FrameSize 512-1023
Displays the accumulated number of 512- to 1023-byte frames sent or received at each port after the system startup.
FrameSize 1024-1518
Displays the accumulated number of 1024- to 1518-byte frames sent or received at each port after the system startup.
Port-Description
Displays port descriptions. If the port is not described, it will not display anything.
Up to 44 characters can be displayed.
204/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15.13 show statistics qos-priority-traffic-bytes
Function
Displays the traffic (the number of frames) for each port with different QoS priorities after system startup.
Prompt
xg> or xg#
Command syntax show statistics qos-priority-traffic-bytes
Command type
Operation management command
Output form
xg# show statistics qos-priority-traffic-bytes
Qos Priority Traffic Statistics(Total Frame Bytes) 2007/01/22-19:46:24
=======================================================================
[No.1]
Port : 1
Priority-0 Bytes : 26560
Priority-1 Bytes : 145366784370
Priority-2 Bytes : 234554675423423
Priority-3 Bytes : 34346331246523
Priority-4 Bytes : 1234114235453466
Priority-5 Bytes : 0
Priority-6 Bytes : 0
Priority-7 Bytes : 0
Port-Description : port_name1
[No.2]
[No.]
Displays statistics for each port.
Port
Displays the port numbers.
Priority-0 Bytes to Priority-7 Bytes
Displays the accumulated number of frames with different QoS priorities received from the startup of this command.
Port-Description
Displays port descriptions. If the port is not described, it will not display anything.
Up to 51 characters can be displayed.
205/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15.14 show statistics qos-priority-traffic-counts
Function
Displays the traffic (the number of frames) for each port with different QoS priorities after system.
Prompt
xg> or xg#
Command syntax show statistics qos-priority-traffic-counts
Command type
Operation management command
Output form
xg# show statistics qos-priority-traffic-counts
Qos Priority Traffic Statistics(Total Frame Counts) 2007/01/22-19:49:53
========================================================================
[No.1]
Port : 1
Priority-0 Counts : 12345678901234567890
Priority-1 Counts : 2354235234
Priority-2 Counts : 235434250
Priority-3 Counts : 12314657
Priority-4 Counts : 235477689352374
Priority-5 Counts : 246364564564546
Priority-6 Counts : 1234453456
Priority-7 Counts : 1436434623
Port-Description : port_name1
[No.2]
[No.]
Displays statistics for each port.
Port
Displays the port numbers.
Priority-0 Counts to Priority-7 Counts
Displays the accumulated number of frames with different QoS priorities received from the startup of this command.
Port-Description
Displays port descriptions. If the port is not described, it will not display anything.
Up to 51 characters can be displayed.
206/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15.15 show statistics vlan-traffic-bytes
Function
Displays the traffic (the number of bytes) for each VLAN after system startup.
Prompt
xg> or xg#
Command syntax show statistics vlan-traffic-bytes
Command type
Operation management command
Output form
xg# show statistics vlan-traffic-bytes
VLAN Traffic Statistics(Total Frame Bytes) 2007/01/22-19:55:34
===============================================================
[No.1]
VID : 40
Rx-Frame Byte : 0
Rx-NonUcast Byte: 0
[No.2]
[No.]
Displays statistics for each VLAN.
VID
Displays the VID of the VLAN set for statistics collection.
Specify the VLAN for statistics collection using the "vlan-statistics collection" command.
Rx-Frame Bytes
Displays the accumulated byte count of frames received at the specified VLAN (after the startup of this command), using a 10-digit, right-justified value.
Rx-NonUcast Bytes
Displays the accumulated byte count of multicast/broadcast frames received at the specified
VLAN after the startup of this command, using a 10-digit, right-justified value.
207/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15.16 show statistics vlan-traffic-counts
Function
Displays the traffic (the number of frames) for each VLAN after system startup.
Prompt
xg> or xg#
Command syntax show statistics vlan-traffic-counts
Command type
Operation management command
Output form
xg# show statistics vlan-traffic-counts
VLAN Traffic Statistics(Total Frame Counts) 2007/01/22-19:58:31
================================================================
[No.1]
VID : 40
Rx-Frame Counts : 0
Rx-NonUcast Counts: 0
[No.2]
[No.]
Displays statistics for each VLAN.
VID
Displays the VID of the VLAN set for statistics collection.
Specify the VLAN for statistics collection using the "vlan-statistics collection" command.
Rx-Frame Counts
Displays the accumulated count of frames received at the specified VLAN (after the system startup), using a 10-digit, right-justified value.
Rx-NonUcast Counts
Displays the accumulated count of non-unicast frames received at the specified VLAN after the system startup, using a 10-digit, right-justified value.
208/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15.17 show statistics dataflow
Function
Displays statistics including the transmission and reception of pause frames at each port and the data transmission type.
Prompt
xg> or xg#
Command syntax show statistics dataflow
Command type
Operation management command
Output form
xg# show statistics dataflow
Dataflow Statistics(Total Counts) 2007/01/22-19:59:17
[No.1]
Port : 1
Link State/ STP State: Up/Forward
Flow-Ctl Mode : disabled
Forward Counts : 0
Flood Counts : 0
Rx-Pause Counts : 0
Tx-Pause Counts : 0
Full-Drop Counts : 0
VLAN-Drop Counts : 0
Port-Description : port_name1
[No.2]
[No.]
Displays statistics for each port.
Port
Displays the port numbers.
Link State/STP State
Displays the port state in the Link State or STP State format.
The Link State may indicate one of the following link states.
− Down
The port link is down.
− Up
The port link is up.
The STP State displays the current port status based on the STP (Spanning Tree Protocol).
Note that the STP State is not displayed if the Link State is down.
For port status details, see “
Spanning Tree Protocol Port States ”.
Flow-Ctl Mode
Displays the flow control setup for each port.
− Rx & Tx
Both transmission and reception of pause frames are enabled.
− Rx
Only the reception of pause frames is enabled.
Forward Counts
Displays the accumulated number of frames forwarded normally (among the unicast frames received at each port after the system startup).
Flood Counts
Displays the accumulated number of flooded frames (among the unicast frames received at each port after the system startup).
Rx-Pause Counts
Displays the accumulated number of pause frames received at each port after the system startup.
Tx-Pause Counts
Displays the accumulated number of pause frames sent from each port after the system startup.
Full-Drop Counts
Displays the number of frames discarded due to the saturated port input buffer of the system after the system startup.
VLAN-Drop Counts
Displays the number of frames discarded due to the reception of non-VLAN member frames that are not allowed to be forwarded among those received at each port after the system startup.
Port-Description
Displays port descriptions. If the port is not described, it will not display anything.
Up to 29 characters can be displayed.
209/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15.18 show statistics error
Function
Displays statistics for errors occurring at each port after system startup.
Prompt
xg> or xg#
Command syntax show statistics error
Command type
Operation management command
Output form
xg# show statistics error
Error Statistics(Total Counts) 2007/01/22-20:21:35
===================================================
[No.1]
Port : 1
Rx CRC : 0
Rx & Tx Over : 0
Rx & Tx Under : 0
Rx & Tx Fragment : 0
Rx & Tx Jabber : 0
Rx Align : 0
Total Lost : 0
Port-Description : port_name1
[No.2]
[No.]
Displays statistics for each port.
Port
Displays the port numbers.
Rx CRC
Displays the accumulated number of FCS (Frame Check Sequence) error frames received after the system startup.
Rx & Tx Over
Displays the accumulated number of transmission frames whose size exceeds 1518 bytes
(excluding the VLAN tag) after the system startup.
Rx & Tx Under
Displays the accumulated number of transmission frames whose size is less than 64 bytes after the system startup.
Rx & Tx Fragment
Displays the accumulated number of FCS (Frame Check Sequence) error frames whose size is less than 64 bytes sent or received after the system startup.
Rx & Tx Jabber
Displays the accumulated number of FCS (Frame Check Sequence) error frames whose size exceeds
1518 bytes (excluding the VLAN tag) sent or received after the system startup.
Rx Align
Displays the accumulated number of 64- to 1518-byte alignment error frames whose bit size is not a multiple of 8 received after the system startup.
Total Lost
Displays the accumulated number of frames received but discarded at each port after the system startup.
If the error count reaches 4294967295, the value is reset to 0 when incremented.
Port-Description
Displays port descriptions. If the port is not described, it will not display anything.
Up to 31 characters can be displayed.
210/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.15.19 clear statistics
Function
Clears all statistics stored since system startup.
The following statistics are cleared.
Traffic statistics: traffic-bytes, traffic-counts and framesize-traffic-counts
QoS traffic statistics: qos-priority-traffic-bytes and qos-priority-traffic-counts
VLAN traffic statistics: vlan-traffic-bytes and vlan-traffic-counts
Data flow statistics: dataflow
Error traffic statistics: error
Prompt
xg#
Command syntax clear statistics
Command type
Operation management command
Note
If this command is issued during execution of the “monitor” command in “current” mode, the “monitor” command may temporarily display incorrect statistics. If this occurs, reissue the “monitor” command. The “monitor” command will then display the correct statistics.
Example
Clear all statistics stored since system startup. xg# clear statistics
211/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.16 SNMP Setup Commands
This section explains the SNMP configuration settings.
5.16.1 show snmp-server
Function
Displays the current SNMP settings.
Prompt
xg> or xg#
Command syntax show snmp-server
Command type
Operation management command
Output form
xg# show snmp-server
SNMP Information 2007/01/22-06:04:41
===============================================================================
SNMP Manager Information
-------------------------------------------------------------------------------
[No.1]
Host : 192.168.41.24
Community : public
[No.2]
Host : 192.168.41.29
Community : public
-------------------------------------------------------------------------------
SNMP Trap Manager Information
-------------------------------------------------------------------------------
[No.1]
Host : 192.168.41.24
Community : public
Version : { v1 | v2c }
[No.2]
Host : 192.168.41.29
Community : public
Version : { v1 | v2c }
===============================================================================
SNMP Manager Information
Displays the current settings of the SNMP manager.
[No.1]
Indicates the number of the SNMP manager displayed. A maximum of four may be defined.
Host
Displays the host name or the IP address of the SNMP manager.
Community
Displays the community name of the SNMP manager.
SNMP Trap Manager Information
Displays the destination SNMP trap being set from the system.
[No.1]
Indicates the number of the SNMP trap item displayed.
Host
Displays the host name or the IP address of the SNMP manager for trap notification.
Community
Displays the community name of the SNMP manager for trap notification.
Version
Displays the SNMP protocol version to be used for trap notification as follows:
− v1
The SNMP v1 protocol is used for trap notification.
− V2
The SNMP v2 protocol is used for trap notification.
212/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.16.2 snmp-server location
Function
Sets the installation location for the device.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax snmp-server location SYSTEM-LOCATION no snmp-server location
Parameter
SYSTEM-LOCATION
Specifies the installation location of the device. The location name can be up to 255 alphanumeric characters.
No need to enclose a parameter in quotes if it contains a blank space.
Command type
Configuration command
Default
None
Message
% SYSTEM-LOCATION is too long.
Explanation
The location name specified by SYSTEM-LOCATION exceeded the length limit.
Solution
Reduce the length of system location name and reissue the command.
% SYSTEM-LOCATION cannot be used.
Explanation
An illegal character was used in the SYSTEM-LOCATION name.
Solution
Review the system location name setting and reissue the command.
Example
Specify the system installation location as “3F West”: xg(config)# snmp-server location 3F West
213/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.16.3 snmp-server contact
Function
Sets the installation contact name for the device.
Use the no form to return to the default setup.
Prompt
xg(config)#
Command syntax snmp-server contact SYSTEM-CONTACT no snmp-server contact
Parameter
SYSTEM-CONTACT
Specifies the system contact name for the device. The contact name can be up to 255 alphanumeric characters.
No need to enclose a parameter in quotes if it contains a blank space.
Command type
Configuration command
Default
None
Message
% SYSTEM-CONTACT is too long.
Explanation
The contact name specified by "SYSTEM-CONTACT" exceeded the length limit.
Solution
Reduce the length of the system contact name and reissue the command.
% SYSTEM-CONTACT cannot be used.
Explanation
An illegal character was used in the "SYSTEM-CONTACT" name.
Solution
Review the system contact name setting and reissue the command.
Example
Specify the system contact address as “administrator tel: 012-3456-7890.” xg(config)# snmp-server contact administrator tel:012-3456-7890
214/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.16.4 snmp-server access
Function
Sets an SNMP agent. The SNMP manager has read-only access privileges. Up to four access-enabled SNMP managers can be registered.
Use the no form to delete the existing SNMP managers.
Prompt
xg(config)#
Command syntax snmp-server access host HOSTNAME community COMMUNITY-NAME no snmp-server access host HOSTNAME
Parameter
host HOSTNAME
Specifies the host name or the IP address of the SNMP manager.
The IP address can be within the range of 1.0.0.1 to 126.255.255.254, 128.0.0.1 to
191.255.255.254, or 192.0.0.1 to 223.255.255.254. community COMMUNITY-NAME
Specifies a community name for the SNMP manager. The community name can be up to 255 alphanumeric characters.
Command type
Configuration command
Default
None
Message
% SNMP Manager can register up to 4.
Explanation
Four SNMP managers have already been registered.
Solution
Delete unnecessary SNMP managers then reissue the command.
% Cannot find %1$
Explanation
The name cannot be resolved. An incorrect host name was specified.
[[Inserted string]]%1$: Specified host name
Solution
Review the host name then reissue the command by specifying a correct host name or IP address.
% Hostname is too long.
Explanation
The specified host name exceeded the length limit.
Solution
Reduce the host name length then reissue the command.
% COMMUNITY-NAME is too long.
Explanation
The specified community name exceeded the length limit.
Solution
Reduce the community name length then reissue the command.
% COMMUNITY-NAME cannot be used.
Explanation
An illegal character was used in the community name.
Solution
Review the community name setting then reissue the command.
% Invalid IP-address.
Explanation
The IP address was specified in an incorrect format or an incorrect address was specified.
Solution
Specify the correct IP address in the correct format then reissue the command.
Note
If a previously defined host name is specified with a new community name the prior community name is overwritten.
Example
Allow access from the SNMP manager having the IP address “192.168.1.10” and the community name “xgpublic”. xg(config)# snmp-server access host 192.168.1.10 community xgpublic
215/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.16.5 snmp-server trap
Function
Sets the destination for SNMP trap notifications. Up to four (4) destinations can be registered.
Use the no form to delete the existing destination names.
Prompt
xg(config)#
Command syntax snmp-server trap host HOSTNAME community COMMUNITY-NAME [ protocol {v1|v2c} ] no snmp-server trap host HOSTNAME
Parameter
host HOSTNAME
Specifies a host name or an IP address for the destination SNMP manager.
The IP address can be within the range of 1.0.0.1 to 126.255.255.254, 128.0.0.1 to
191.255.255.254, or 192.0.0.1 to 223.255.255.254. community COMMUNITY-NAME
Specifies a community name for the destination SNMP manager. The community name can be up to 255 alphanumeric characters.
[ protocol {v1|v2c} ]
Specifies the SNMP protocol to be used.
− v1
The SNMP v1 protocol is used for trap notification.
− v2c
The SNMP v2c protocol is used for trap notification.
The SNMP v2c protocol is the default if not specified.
Command type
Configuration command
Default
None
Message
% SNMP Trap Manager can register up to 4.
Explanation
Four SNMP trap managers have already been registered.
Solution
Delete unnecessary SNMP trap managers then reissue the command.
% Cannot find %1$
Explanation
The name cannot be resolved. An incorrect host name was specified.
[[Inserted string]]%1$: Specified host name
Solution
Review the host name then reissue the command by specifying the correct hostname or IP address.
% Hostname is too long.
Explanation
The specified host name exceeded the length limit.
Solution
Reduce the host name length then reissue the command.
% COMMUNITY-NAME is too long.
Explanation
The specified community name exceeded the limit length.
Solution
Review the community name length then reissue the command.
% COMMUNITY-NAME cannot be used.
Explanation
An illegal character was used in the community name.
Solution
Review the community name setting then reissue the command.
% Invalid IP-address.
Explanation
The IP address was specified in an incorrect format or an incorrect address was specified.
Solution
Specify the correct IP address in the correct format then reissue the command.
Note
If a previously defined host name is specified with new parameters the prior parameters are overwritten.
Example
Specify trap notification using the SNMP v2c protocol for the SNMP manager with the IP address “192.168.1.10” and the community name “xgpublic”. xg(config)# snmp-server trap host 192.168.1.10 community xgpublic protocol v2c
216/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.17 RMON Setup Commands
This section explains the RMON configuration settings.
5.17.1 show rmon
Function
Displays the current RMON settings.
Prompt
xg> or xg#
Command syntax show rmon
Command type
Operation management command
Output form
xg# show rmon
RMON Information 2007/01/22-06:03:09
===============================================================================
History Information
-------------------------------------------------------------------------------
[History 1]
Port : port-1
Buckets : 10
Interval: 1800
Owner : Administer
-------------------------------------------------------------------------------
Alarm Information
-------------------------------------------------------------------------------
[Alarm 1]
Monitored OID : .1.3.6.1.2.1.16.1.1.1.7.1
Monitoring Interval: 10
Sample Type : { Absolute | Delta }
Rising Threshold : 1000
Rising Event : 1
Falling Threshold : 0
Falling Event : 0
Owner : Administer
-------------------------------------------------------------------------------
Event Information
-------------------------------------------------------------------------------
[Event 1]
Event Type
Log : { Enabled | Disabled }
Trap : { Enabled | Disabled }
Trap Community : public
Description : Traffic alarm event
Owner : Admin
===============================================================================
History Information
Displays the current RMON history settings.
[History 1]
Indicates an index number that identifies the history group (historyControlTable).
Port
Displays the port number for the collected RMON history group information.
Buckets
Indicates the stored data unit count for the RMON history group.
Interval
Indicates an interval (in seconds) for collecting the RMON history group data.
Owner
Displays the owner name of the RMON history group.
Alarm Information
Displays the current RMON alarm settings.
[Alarm 1]
Indicates a unique ID assigned to the RMON alarm.
Monitored OID
Indicates an OID within the MIB object to be monitored.
Monitoring Interval
Indicates an interval (in seconds) for threshold check of the MIB to be monitored.
217/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Sample Type
Displays the threshold evaluation method.
− Absolute
The value obtained from the MIB is evaluated based on the absolute value.
− Delta
The difference between the value obtained from the previous MIB and the value obtained from the current MIB is evaluated.
Rising Threshold
Indicates the threshold upper limit (or the rising threshold).
Rising Event
Indicates a number for the event notification if the value obtained exceeded the threshold limit.
Event does not occur if the value is 0.
Falling Threshold
Indicates the threshold lower limit (or the falling threshold).
Falling Event
Indicates a number for the event notification if the value obtained dropped below the threshold limit.
Event does not occur if the value is 0.
Owner
Displays the owner name of the RMON alarm group.
Event Information
Displays the contents of the RMON event.
[Event 1]
Indicates an index number that identifies the RMON event entry.
Event Type log
Displays the status of the RMON log entry creation when a RMON event occurred.
− Enabled
A RMON log entry was created.
− Disabled
No RMON log entry was created.
Trap
Displays the trap notification status.
− Enabled
SNMP trap notification occurs.
− Disabled
No SNMP trap notification occurs.
Trap Community
Displays a community name for the SNMP trap.
Description
Displays a character string that explains the RMON event entry.
Owner
Displays the owner name of the RMON event entry.
218/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.17.2 rmon collection history
Function
Sets an RMON history. Up to 40 entries can be set.
Use the no form to delete the information set.
Prompt
xg(config)#
Command syntax rmon collection history INDEX { port <1-20> | agg-port <1-10> }
[buckets BUCKET-NUM] [interval SECOND] [owner OWNERNAME] no rmon collection history INDEX
Parameter
INDEX
Specifies an entry index number for the history within the range of 1 to 65535. port <1-20>
Specifies a port number for collection of the RMON history group. agg-port <1-10>
Specifies an aggregation group number for collecting of the RMON history group. buckets BUCKET-NUM
Specifies the data storage unit count of the RMON history entry group within the range of
1 to 20.
If omitted, the default storage count is 10 data sets. interval SECOND
Specifies a time interval for collecting the RMON history group data within the range of
1 to 3600 seconds.
If omitted, the default interval is 1800 seconds (or 30 minutes). owner OWNERNAME
Specifies an owner name of the entry using up to 127 characters.
If omitted, no owner name is set.
Command type
Configuration command
Default
None
Message
% RMON collection history can register up to 40
Explanation
The RMON history group data entry registration limit was exceeded.
Solution
Delete unnecessary RMON history groups then reissue the command.
% RMON collection history %1$ is not set.
Explanation
An attempt was made to delete a non-existing RMON history group.
[[Inserted string]]%1$: Index number
Solution
Review the specified index then reissue the command.
% OWNERNAME is too long.
Explanation
The specified “ownername” exceeded the length limit.
Solution
Reduce the “ownername” length then reissue the command.
% Agg-port %1$ does not exist
Explanation
The specified aggregation group was not created.
[[Inserted string]]%1$: Specified aggregation group number
Solution
Review the “agg-port” settings then reissue the command.
% OWNERNAME cannot be used.
Explanation
An illegal character was specified in the "ownername".
Solution
Review the specified “ownername” then reissue the command.
% It failed in the snmpset command.
Explanation
It fails to set RMON because the command was executed while the SNMP manager was accessing.
Solution
While the SNMP is not accessing, execute the no command and set RMON again.
Example
Set the data collection interval to 30 minutes (default value) and the data storage count to 20 data sets for the RMON history for port 1. The 10-hour history statistics will be logged. xg(config)# rmon collection history 1 port 1 buckets 20
219/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.17.3 rmon alarm
Function
Sets RMON alarms. Up to 30 entries can be set.
Use the no form to delete entries previously set.
Prompt
xg(config)#
Command syntax rmon alarm INDEX VARIABLE interval VALUE {absolute | delta}
rising-threshold VALUE [EVENT-NUM] falling-threshold VALUE [EVENT-NUM]
[owner OWNERNAME] no rmon alarm INDEX
Parameter
INDEX
Specifies an entry index number for the RMON alarm within the range of 1 to 65535.
VARIABLE
Specifies an OID for the MIB object to be monitored.
A name such as “ifEntry.10.2” cannot be set for the OID. The OID must be a string of decimal integers separated by a period (.). An example: “1.3.6.1.2.1.1.2.2.1.10.2”.
interval VALUE
Specifies an interval (in seconds) for threshold checks on the MIB to be monitored. The VALUE can be an integer of 2 to 65535.
{absolute | delta}
Specifies a threshold evaluation method as follows.
− absolute
The value obtained from the MIB is evaluated based on the absolute value.
− delta
The difference between the value obtained from the previous MIB and the value obtained from the current MIB is evaluated. rising-threshold VALUE [EVENT-NUM]
The VALUE specifies the threshold upper limit or the “rising threshold.”
The EVENT-NUM specifies an index for the event to be executed if the rising threshold is exceeded.
If EVENT-NUM is omitted, event will not occur. falling-threshold VALUE [EVENT-NUM]
The VALUE specifies the threshold lower limit or the “falling threshold.”
The EVENT-NUM specifies an index for the event to be executed if the falling threshold is exceeded.
If EVENT-NUM is omitted, event will not occur. owner OWNERNAME
Specifies an owner name for the entry using up to 127 alphanumeric characters.
If omitted, no owner name is set.
Command type
Configuration command
Default
None
Message
% RMON alarm can register up to 30
Explanation
The RMON alarm group data entry registration limit was exceeded.
Solution
Delete unnecessary RMON alarm groups then reissue the command.
% RMON alarm %1$ is not set.
Explanation
An attempt to delete a non-existing RMON alarm group occurred.
[[Inserted string]]%1$: Specified index
Solution
Review the specified index then reissue the command.
% OWNERNAME is too long.
Explanation
The “ownername” length limit was exceeded.
Solution
Reduce the “ownername” length then reissue the command.
% OID cannot be used.
Explanation
An illegal character was specified in the OID.
Solution
Review the specified OID then reissue the command.
% OWNERNAME cannot be used.
Explanation
An illegal character was specified in the "ownername".
Solution
Review the specified “ownername” then reissue the command.
220/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
% It failed in the snmpset command.
Explanation
It fails to set RMON because the command was executed while the SNMP manager was accessing.
Solution
While the SNMP is not accessing, execute the no command and set RMON again.
Example
Set RMON alarms: xg(config)# rmon alarm 10 .1.3.6.1.2.1.16.1.1.1.7.1 interval 60 absolute
rising-threshold 15 1 falling-threshold 0 1 owner "admin"
221/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.17.4 rmon event
Function
Sets an RMON event. Up to 60 entries can be set.
Use the no form to delete the information set.
Prompt
xg(config)#
Command syntax rmon event INDEX [ log ] [ trap COMMUNITY ] [ description DESCRIPTION-STRING ]
[owner OWNERNAME] no rmon event INDEX
Parameter
INDEX
Specifies an entry index number for the RMON event within the range of 1 to 65535. log
Delete unnecessary RMON events then reissue the command. trap COMMUNITY
This option notifies a trap if an event occurred. The COMMUNITY name can be up to 127 alphanumeric characters.
If omitted, no traps are notified. description DESCRIPTION-STRING
Specifies a character string that explains the events. The description string can be up to
127 alphanumeric characters. owner OWNERNAME
Specifies an owner name for the entry using up to 127 alphanumeric characters.
If omitted, no owner name is set.
Command type
Configuration command
Default
None
Message
% RMON event can register up to 60
Explanation
The RMON event group data entry registration limit was exceeded.
Solution
Delete unnecessary RMON events then reissue the command.
% RMON event %1$ is not set.
Explanation
An attempt to delete a non-existing RMON event group occurred.
[[Inserted string]]%1$: Specified index
Solution
Review the specified index then reissue the command.
% OWNERNAME is too long.
Explanation
The “ownername” length limit was exceeded.
Solution
Reduce the “ownername” length then reissue the command.
% COMMUNITY is too long.
Explanation
The specified “community” name length limit was exceeded.
Solution
Reduce the “community” name length then reissue the command.
% DESCRIPTION is too long.
Explanation
The “description” specified exceeded the length limit.
Solution
Review the “description” length and reissue the command.
% COMMUNITY cannot be used.
Explanation
An illegal character was specified in the “community” name.
Solution
Review the specified “community” name then reissue the command.
% DESCRIPTION cannot be used.
Explanation
An illegal character was specified in the "description".
Solution
Review the specified “description” then reissue the command.
% OWNERNAME cannot be used.
Explanation
An illegal character was specified in the "ownername".
Solution
Review the specified “ownername” then reissue the command.
222/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
% It failed in the snmpset command.
Explanation
It fails to set RMON because the command was executed while the SNMP manager was accessing.
Solution
While the SNMP is not accessing, execute the no command and set RMON again.
Note
An RMON event entry must be created using the "rmon event" command for log creation or SNMP trap notification to occur.
Example
Set RMON events: xg(config)# rmon event 1 log trap public description "event test1" owner "admin" xg(config)# rmon event 2 log description "event test2" owner "admin"
223/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.18 System Operation Display Commands
This section explains commands that display the system’s operational status.
5.18.1 show system status
Function
Displays the hardware operational status.
For explanations and actions to be taken for each item, see the "
Prompt
xg> or xg#
Command syntax show system status
Command type
Operation management command
Output form
xg# show system status
System Status Information 2007/01/25-12:16:19
==============================================
[Temperature]
Internal : good
[Power Supply]
PWR-0 : good
PWR-1 : good
[Voltage]
Voltage : good
[Fan]
Rear Fan-0 : good (normal-speed)
Rear Fan-1 : good (normal-speed)
PWR-0 Fan : good
PWR-1 Fan : good
[XFP]
port 1 (VENDER-NAME. :S ) : good
port 2 (VENDER-NAME. :L ) : good
port 3 (VENDER-NAME. :S ) : good
port 4 (VENDER-NAME. :L ) : good
port 5 (VENDER-NAME. :S ) : good
port 6 (VENDER-NAME. :L ) : good
port 7 (VENDER-NAME. :S ) : good
port 8 (VENDER-NAME. :L ) : good
port 9 (VENDER-NAME. :S ) : good
port 10 (VENDER-NAME. :L ) : good
port 11 (VENDER-NAME. :S ) : good
port 12 (VENDER-NAME. :L ) : good
port 13 (VENDER-NAME. :S ) : good
port 14 (VENDER-NAME. :L ) : good
port 15 (VENDER-NAME. :S ) : good
port 16 (VENDER-NAME. :L ) : good
port 17 (VENDER-NAME. :S ) : good
port 18 (VENDER-NAME. :L ) : good
port 19 (VENDER-NAME. :S ) : good
port 20 (VENDER-NAME. :L ) : good
Temperature
Displays the temperature status of the system hardware.
− Internal
Internal temperature sensor
Power Supply
Displays the operational status of the power supplies.
− PWR-0
Displays the operational status of power supply 0.
− PWR-1
Voltage
Displays the operational status of power supply 1.
Displays the supply voltage status. If all the voltages are normal, no information is displayed.
− VDP
Displays the VDP voltage status.
− VDE
Displays the VDE voltage status.
− VDR
Displays the VDR voltage status.
− VDD
Displays the VDD voltage status.
− VDN
Displays the VDN voltage status.
224/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
− 1.5V
Displays the 1.5V voltage status on the CPU board.
− 3.3V
Displays the 3.3V voltage status on the CPU board.
− 12V
Displays the 12V voltage status on the CPU board.
− 3.3V
Displays the 3.3V voltage status on the switch ASIC board.
− 12V
Displays the 12V voltage status on the switch ASIC board.
Fan
Displays the fan operational status.
− Rear Fan-0
Displays the operational status of rear fan 0.
− Rear Fan-1
Displays the operational status of rear fan 1.
− PWR-0 Fan
Displays the operational status of the fan mounted in power supply 0.
− PWR-1 Fan
Displays the operational status of the fan mounted in power supply 1.
XFP
Displays the XFP status for each port.
− port xx (yy-zz)
Displays the XFP status of port xx. The vender name, yy, and PHY type, zz, are also displayed.
The number of displayed ports is depend on the device. 20 ports are displayed for XG2000 and 4 ports for XG2000C and XG2000CR.
225/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.18.2 show system information
Function
Displays the operational status of the device.
Prompt
xg> or xg#
Command syntax show system information
Command type
Operation management command
Output form
xg# show system information
System Information 2007/01/22-21:06:11
=======================================
System Name (hostname) : xg
System Location : (none)
System Contact : (none)
Default Banner : XG2000 E10L11 Z01
Startup Time : 2007/01/22-19:28:24
Startup-config Modified : 2007/01/22-19:54:01
Firmware Information
Firmware[1] : E10L10 Z01 2007/01/21-18:42:52
Updated Time : 2007/01/21-22:08:12
Firmware[2] : E10L11 Z01 2007/01/22-19:27:12
Updated Time : 2007/01/23-10:57:53
Current Firmware : [2]
Next Startup Firmware : [2]
Boot Loader : E10L10 Z01
Timezone : gmt +0900
(Next Boot) : gmt -800
Summer-Time : (none)
(Next Boot) : M4.1.0/0200 M10.5.0/0200 0100
RS232C Baud-Rate : 9600
Management LAN Information
MAC Address : 0080.17c2.0500
IP Address/Mask : 192.168.41.22/24
Default Gateway : 192.168.41.1
DNS Server : 192.168.77.20
Domain Name : abc.efg.com
System Load Information
CPU Used Ratio : 1%
Memory Used Size : 36,429,824 bytes (57%)
System Name (hostname)
Displays the system name (host name) of the device.
System Location
Displays the installation location of the device.
System Contact
Displays the contact information of the device.
Default Banner
Displays the default banner string displayed during user login.
Startup Time
Displays the date and time when the system was started up.
Startup-config Modified
Displays the date and time when the “startup-config” setup was last updated.
Firmware Information
Displays the firmware status of the device.
The system retains up to two sets of firmware information (old and new firmware information) and firmware images.
− Firmware[1] / Firmware[2]
Displays the firmware information of firmware partitions 1 and 2 and the firmware update status.
(No display other than revision and revision date)
The new firmware is not being updated.
(writing)
The new firmware is being updated.
(new)
The firmware was updated.
(incomplete)
The switch fails to update the new firmware.
Retry to update the new firmware.
− Updated Time
Displays the date and time when the firmware was last updated.
− Current Firmware
Displays the partition number of the firmware currently being used for system startup.
− Next Startup Firmware
Displays the partition number of the firmware to be used for the next system startup.
− Boot Loader
Displays boot loader revision.
Timezone
Displays the current time zone settings.
226/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
If the time zone settings were changed, the new settings are displayed in the “Next Boot” area. Once the system is restarted the new settings appear as the Timezone setting.
Summer-Time
Displays the current summer time settings.
If the summer time settings were changed, the new settings are displayed in the “Next Boot” area. Once the system is restarted the new settings appear as the Summer-time setting.
RS232C Baud-Rate
Displays the serial (RS-232C) baud rate.
Management LAN Information
Displays the current status of the management LAN interface.
− MAC Address
Displays the MAC address.
− IP Address/Mask
Displays the IP address and the subnet mask bit length.
− Default Gateway
Displays the IP address of the default gateway.
− DNS Server
Displays the IP address of the DNS server.
− Domain Name
Displays the domain name.
System Load Information
− CPU Used Ratio
Displays the CPU usage ratio.
− Memory Used Size
Displays both the currently used size of memory and the current memory usage ratio.
227/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.19 System Maintenance Commands
5.19.1 clear log
Function
Initializes the system log.
Prompt
xg#
Command syntax clear log [ { info | warning | error | critical } ]
Parameter
{ info | warning | error | critical }
Specifies the type of system log to be initialized.
− info
Initializes the INFO log.
The INFO log stores informational (INFO) messages that report on the system status of the device.
− warning
Initializes the WARNING log.
The WARNING log stores warning (WARNING) messages that report on the system status of the device.
− error
Initializes the ERROR log.
The ERROR log stores error (ERROR) messages that report on the system status of the device.
− critical
Initializes the CRITICAL log.
The CRITICAL log stores critical (CRITICAL) messages that report on the system status of the device.
If this log-type parameter is omitted, all logs are initialized.
Command type
Operation management command
Example
Initialize the INFO log: xg# clear log info
228/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.19.2 show log
Function
Displays system logs.
Prompt
xg#
Command syntax show log { info | warning | error | critical } [ latest <1-10000> ]
Parameter
{ info | warning | error | critical }
Specifies the type of system log to be displayed.
− info
Displays the INFO log.
The INFO log stores informational (INFO) messages that report on the system status of the device.
− warning
Displays the WARNING log.
The WARNING log stores warning (WARNING) messages that report on the system status of the device.
− error
Displays the ERROR log.
The ERROR log stores error (ERROR) messages that report on the system status of the device.
− critical
Displays the CRITICAL log.
The CRITICAL log stores critical (CRITICAL) messages that report on the system status of the device. latest <1-10000>
Specifies the number of most current log entries to be displayed within the range of 1 to
10000.
If omitted, all logs are displayed.
Command type
Operation management command
Output form
xg# show log info latest 1
May 25 22:08:33 xghost xgsh: XG INFO[P4001]: cmd-exec[3388]: show log info
| | | | | | | |
Month
|
Hours Min Sec
|
Function name Severity | Message text
Day The device's MessageID
Host name
Month
Displays the month when the event occurred.
Day
Displays the day when the event occurred.
Hours Min Sec
Displays the time (hours, minutes and seconds) when the event occurred.
Host name of the device
Displays the host name of the XG2000 series.
Function name
Displays the function name.
Severity
Indicates the severity of the message.
− CRITICAL
Critical level.
The system failed to continue its operation. Follow the instructions given by the message.
− ERROR
Error level.
A portion of the system functions have failed although the system can continue operation.
Follow the instructions given by the message.
− WARNING
Warning level.
There is no problem with the system operations although an error or a warning event was detected. Check the message information and determine the actions necessary to take.
− INFO
Informational level.
This is an informational message displaying a system status change. No response is necessary.
MessageID
Displays the message ID in the “S message number” or “P message number” format.
− S
Indicates that the message is an SNMP trap notification.
− P
Indicates that the message is not an SNMP trap notification.
− Message number
Displays a unique number for message identification. Read this message number to locate
229/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide the message and take necessary actions.
Message text
Displays the message text.
Example
Display 10 entries of the latest INFO log: xg# show log info latest 10
5.19.3 log send
Function
Transfers the system log from the device to a remote host.
Prompt
xg(config)#
Command syntax log send HOST { info | warning | error | critical } [ { udp | tcp } ] no log send
Parameter
HOST
Specifies the host name, domain name or IP address of the system log destination.
When specifying the host name or the domain name, set the DNS server or register the host name in advance.
The IP address can be within the range of 1.0.0.1 to 126.255.255.254, 128.0.0.1 to
191.255.255.254, or 192.0.0.1 to 223.255.255.254.
If transferring system logs to a Linux host, log information can be received by specifying “–syslogd -r”.
{ info | warning | error | critical }
Specifies the type of system logs to be transferred.
− info
Transfers the CRITICAL, ERROR, WARNING and INFO messages.
− warning
Transfers the CRITICAL, ERROR and WARNING messages.
− error
Transfers the CRITICAL and ERROR messages.
− critical
Transfers the CRITICAL level messages.
{ udp | tcp }
Selects a protocol for transmission of system logs. The “udp” (User Datagram Protocol) is selected by default.
Command type
Operation management command
Message
% Invalid IP-address.
Explanation
The IP address was specified in an incorrect format or an incorrect address was specified.
Solution
Specify the correct IP address in the correct format then reissue the command.
230/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.19.4 save maintenance
Function
Stores the current internal system status in non-volatile memory.
Prompt
xg#
Command syntax save maintenance
Command type
Operation management command
Note
Up to 5 maintenance information is saved, and the oldest maintenance information is overwritten when exceeded.
The detail of 5 maintenance information is following.
− system dump: 1
− process dump: 1
− system state: 1
5.19.5 show maintenance
Function
Displays the maintenance information.
Prompt
xg#
Command syntax show maintenance
Command type
Operation management command
Output form (if "current" is specified)
xg# show maintenance
Maintenance Information 2007/01/22-20:58:17
====================================================
NO Type Occurred Time
--- -------------------------- ---------------------
1 system dump 2007/01/22-18:21:23
2 system dump(dump switch) 2007/01/22-19:57:58
3 system dump(machine check) 2007/01/22-19:58:14
====================================================
NO
Displays the maintenance information number. The oldest maintenance information is displayed first.
Type
Displays the maintenance information type.
− system dump
A system dump was logged during system failure
− system dump(dump switch)
A system dump was forcibly logged by the “dump” switch
− system dump(machine check)
A system dump was logged due to a hardware machine check
− process dump
The process dump was logged during a partial system failure
− system state
The system operational status information output by the “save maintenance” command
Occurred Time
Displays the date and time when the maintenance information was logged.
Nothing is displayed if maintenance information does not exist.
231/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.19.6 tftp put-maintenance
Function
Transfers the system maintenance information to a TFTP server.
The file size of the maintenance information is displayed on the screen.
Prompt
xg#
Command syntax tftp put-maintenance HOST [ REMOTE-FILE ]
Parameter
HOST
Specifies the host name or the IP address of the TFTP server.
The IP address can be within the range of 1.0.0.1 to 126.255.255.254, 128.0.0.1 to
191.255.255.254, or 192.0.0.1 to 223.255.255.254.
REMOTE-FILE
Specifies the path and file name the maintenance information will reside in once transferred to the TFTP server. If the file name is omitted, the following file name is generated automatically:
"mainte_2007_01_31_13_30_59” (date and time when obtained).
Command type
Operation management command
Message
% tftp: %1$: Host name lookup failure
Explanation
The specified host name does not exist.
[[Inserted string]]%1$: Specified host name
Solution
Check the host name for an error.
% tftp: server says: %1$
Explanation
An error was reported from the TFTP server.
[[Inserted string]]%1$: Error messages sent from the FTP server
The message contents vary depending on the TFTP server type used. Typical messages are as follows.
− File not found: No file is found on the TFTP server.
− Access violation: An error of file access authority occurred on the TFTP server.
− Not allowed to overwrite existing files: The file in the TFTP server cannot be overwritten.
− Could not open requested file for reading: There are no files in the TFTP server.
− File already exists: The specified file already exists on the TFTP server.
− Unknown transfer ID: The process is interrupted due to the timeout.
Solution
Take actions by following the message instructions sent from the TFTP server.
% tftp: last timeout
Explanation
There is no response by the TFTP server. The network communication with the management
LAN may have failed or too short a timeout was set on the TFTP server.
Solution
Issue a “ping” command to check the network connection to the TFTP server. If an error recurs, change the timeout value of the TFTP server.
% Invalid IP-address.
Explanation
The IP address was specified in an incorrect format or an incorrect address was specified.
Solution
Specify the correct IP address in the correct format then reissue the command.
Note
If the file or directory specified by REMOTE-FILE does not exist on the TFTP server, an error may occur (it depends on the TFTP server functions).
If too short a timeout was set on the TFTP server, an error may occur (it depends on the TFTP server functions).
To ensure the transmission of all the maintenance information, compare the file size displayed on the screen and the size of the file saved on the TFTP server.
232/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Example
Save the current system status data as a maintenance information file in non-volatile memory then check the logged status of the maintenance information using the “show maintenance” command.
Transfer the maintenance information to the “host1” TFTP server by naming it as the “mainte_collected date and time” file.
Compare the file size of the maintenance information displayed on the screen to the size of the file stored on the TFTP server. xg# save maintenance xg# show maintenance
Maintenance Information 2007/01/22-20:58:17
==================================================
NO Type Occurred Time
--- -------------------------- -------------------
1 system dump 2007/01/22-18:21:23
2 system dump(dump switch) 2007/01/22-20:57:58
3 system dump(machine check) 2007/01/22-20:58:14
================================================== xg# tftp put-maintenance host1
Total file size: 480711 (bytes)
5.19.7 clear maintenance
Function
Clears the maintenance information from non-volatile memory on the device.
Prompt
xg#
Command syntax clear maintenance
Command type
Operation management command
Note
Issue the “clear maintenance” command only after checking for a successful file transfer to the TFTP server using the
“tftp put-maintenance” command.
Example
Clear the maintenance information from non-volatile memory: xg# clear maintenance
233/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.19.8 update-system
Function
Updates the firmware on the device.
The device stores two firmware images. This command updates the standby firmware. The updated firmware is made valid after the next system startup.
Prompt
xg#
Command syntax update-system local FILE-NAME update-system tftp HOST REMOTE-FILE
Parameter
local FILE-NAME
Specifies the firmware image file that was downloaded from the TFTP server to non-volatile memory in the device. tftp HOST
Directly updates the firmware from the firmware image file stored on the TFTP server.
To do so, specify the host name or the IP address of the TFTP server.
The IP address must be within the range of 1.0.0.1 to 126.255.255.254, 128.0.0.1 to
191.255.255.254, or 192.0.0.1 to 223.255.255.254.
REMOTE-FILE
Specifies the firmware image file residing on the TFTP server.
Command type
Operation management command
Message
% File not found.
Explanation
The specified file was not found.
Solution
Check the file name for an error.
% Reading the file failed.
Explanation
The specified file could not be read.
Solution
Check that the file is read enabled.
% Checksum error: %1$ in the file
Explanation
A data error was detected in the specified file.
[[Inserted string]]%1$: Firmware configuration module
Solution
Check the file for an error in its contents.
If the file contents are OK, an error may have occurred during file transmission. Transfer the file again.
% Checksum error: whole file
Explanation
A data error (a checksum error of the entire file) was detected.
Solution
Check the file for an error in its contents.
If the file contents are OK, an error may have occurred during file transmission. Transfer the file again.
% Version of the format of the file is not suitable for this system.
Explanation
The firmware revision of the specified file cannot be used with the system hardware.
Solution
Specify the correct file to update the system firmware.
% The file is not for this system.
Explanation
The firmware revision of the specified file cannot be used with the system hardware.
Solution
Specify the correct file to update the system firmware.
% Reading boot loader partition in FlashROM failed.
Explanation
An error occurred during a read of flash ROM data.
Solution
Retry firmware updating.
If the error recurs, contact the sales representative.
% Writing %1$ into FlashROM failed.
Explanation
An error occurred while writing to flash ROM.
[[Inserted string]]%1$: Firmware configuration module
Solution
Retry firmware updating.
If the error recurs, contact the sales representative.
% Checksum error: %1$ in FlashROM
Explanation
An error occurred while writing to flash ROM.
[[Inserted string]]%1$: Firmware configuration module
Solution
Retry firmware updating.
234/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
If the error recurs, contact the sales representative.
% %1$ in SRAM is invalid.
Explanation
An inconsistency in non-volatile (SRAM) memory data was detected.
[[Inserted string]]%1$: Abnormal memory contents
Solution
Restart the system using the “reset” command. Then, retry firmware updating.
If the error recurs, contact the sales representative.
% tftp: %1$: Host name lookup failure
Explanation
The specified host name does not exist.
[[Inserted string]]%1$: Specified host name
Solution
Check the host name for an error.
% tftp: server says: %1$
Explanation
An error was reported from the TFTP server.
[[Inserted string]]%1$: Error messages sent from the FTP server
The message contents vary depending on the TFTP server type used. Typical messages are as follows.
− File not found: No file is found on the TFTP server.
− Access violation: A file access violation occurred on the TFTP server.
− Not allowed to overwrite existing files: The file in the TFTP server cannot be overwritten.
− Could not open requested file for reading: The file does not exist on the TFTP server.
− File already exists: There are files in the TFTP server.
− Unknown transfer ID: Process will be aborted in time out.
Solution
Take actions by following the message instructions sent from the TFTP server.
% tftp: write: No space left on device
Explanation
The non-volatile memory on the device has insufficient work area. A portion of the file being downloaded may remain in the non-volatile memory.
Solution
Delete the downloaded file and unnecessary files on the system using the “delete” command.
Then, reissue the “update-system” command.
% tftp: last timeout
Explanation
There is no response from the TFTP server. The network may have failed or too short a timeout was set on the TFTP server.
Solution
Issue a “ping” command to check the network connection to the TFTP server. If the error recurs, change the timeout value on the TFTP server.
% Invalid IP-address.
Explanation
The IP address was specified in an incorrect format or an incorrect address was specified.
Solution
Specify the correct IP address in the correct format then reissue the command.
Example
Download the firmware image file into the system volatile memory using the “tftp get” command. Check the size of the downloaded firmware image file using the “ls” command.
Then, update the firmware using the “update-system” command. xg# tftp get tftp-host1 firm_upd_file xg# ls
Update-time File-size File-name
- 2007/01/31 13:52:54 5,754,559 firm_upd_file
unused: 8,888,320 bytes xg# update-system local firm_upd_file
Update the firmware directly from the TFTP server. xg# update-system tftp tftp-host1 firm_upd_file
After the firmware was updated successfully, check the firmware version (E/L) and make sure that the system firmware was set to “(new)” using the “show system information” command.
Also, check the “Next Startup Firmware” value. This firmware image will be booted during the next system startup. xg# show system information
Firmware Information
Firmware[1] : E10L10 Z01 2007/01/21-18:42:52
Updated Time : 2007/01/21-22:08:12
Firmware[2] : E10L11 Z01 2007/01/22-19:27:12 {(writing)|(new)}
Updated Time : 2007/01/23-10:57:53
↑
Current Firmware : [1]
The updating status is displayed.
Next Startup Firmware
: [2]
After the updating process completes, restart the system hardware. xg# reset
235/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
5.19.9 boot-system
Function
Switches the firmware image to be used for the next system startup.
Use this command only if a problem occurred using new firmware.
Prompt
xg#
Command syntax boot-system { 1 | 2 }
Parameter
{ 1 | 2 }
Specifies the number of the firmware partition to be used during the next system startup.
The applicable firmware version can be checked by the “show system information” command.
− 1
Uses firmware 1 for the next system startup.
− 2
Uses firmware 2 for the next system startup.
Command type
Operation management command
Message
% Attempted to change to invalid firmware. Command failed.
Explanation
The previous firmware update may not have completed successfully. The firmware partition is unusable.
Solution
Update the firmware again.
If the error recurs, contact the sales representative.
% 1$ in SRAM is invalid.
Explanation
An inconsistency in non-volatile (SRAM) memory data was detected.
[[Inserted string]]%1$: Abnormal memory contents
Solution
"Restart the system using the “reset” command. Then, retry the firmware update.
If the error recurs, contact the sales representative.
Example
Change the firmware to be used for the next system startup using the “boot-system” command.
Check that the firmware information (Next Startup Firmware) to be used for the next system startup changed using the “show system information” command. xg# boot-system 1 xg# show system information
Firmware Information
Firmware[1] : E10L10 Z01 2007/01/23-18:42:52
Updated Time
: 2007/01/21-22:08:12
Firmware[2] : E10L11 Z01 2007/01/31-19:27:12
Updated Time
: 2007/01/31-19:57:53
Current Firmware : [2]
Next Startup Firmware: [1]
236/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Chapter 6 Managing the Device
This chapter describes the management of the device.
237/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
6.1 Verifying the Device Operations
This chapter describes the management of the device.
Hardware status
System status
Log messages
6.1.1 Verifying Hardware Status
Verify the status of hardware by entering the "
show system status " command in the operator EXEC mode or in the
administrator EXEC mode. The following example shows the information that is displayed when the "
command is entered. xg# show system status
System Status Information 2007/01/25-12:16:19
==============================================
[Temperature]
Internal : good
[Power Supply]
PWR-0 : good
PWR-1 : good
[Voltage]
Voltage : good
[Fan]
Rear Fan-0 : good (normal-speed)
Rear Fan-1 : good (normal-speed)
PWR-0 Fan : good
PWR-1 Fan : good
[XFP]
port 1 (VENDER-NAME. :S ) : good
port 2 (VENDER-NAME. :L ) : good
port 3 (VENDER-NAME. :S ) : good
port 4 (VENDER-NAME. :L ) : good
port 5 (VENDER-NAME. :S ) : good
port 6 (VENDER-NAME. :L ) : good
port 7 (VENDER-NAME. :S ) : good
port 8 (VENDER-NAME. :L ) : good
port 9 (VENDER-NAME. :S ) : good
port 10 (VENDER-NAME. :L ) : good
port 11 (VENDER-NAME. :S ) : good
port 12 (VENDER-NAME. :L ) : good
port 13 (VENDER-NAME. :S ) : good
port 14 (VENDER-NAME. :L ) : good
port 15 (VENDER-NAME. :S ) : good
port 16 (VENDER-NAME. :L ) : good
port 17 (VENDER-NAME. :S ) : good
port 18 (VENDER-NAME. :L ) : good
port 19 (VENDER-NAME. :S ) : good
port 20 (VENDER-NAME. :L ) : good
238/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Item
The following table provides descriptions of items displayed when the "show system status" command is entered and an explanation of each error message.
Item displayed
Temperature
Internal (internal temperature sensor)
Message explanation/Solution
Displays the temperature inside the chassis. good
The temperature is within normal operating range. caution
The temperature is high, but within normal operating range. The system will be shutdown if it reaches the alarm threshold.
− Check that the air vent is not blocked.
− Check that the temperature of the switch location is within the limits specified.
Temperature is out of range. (xx yy)
The temperature is out of normal operating range. If the temperature exceeds high alarm threshold, the system will be shutdown.
− Check that the air vent is not blocked.
− Check that the temperature of the set up location is within the limits set out by the operation guarantee.
If the same message is displayed after re-examining the set up of the device, contact the sales representative.
Power Supply
PWR - 0 (status of power supply unit 0)
Voltage
PWR - 1 (status of power supply unit 1)
Display the status of power supply unit. good
The power supply unit 0 is properly installed and functional.
Removed
The power supply unit 0 was removed. If this message appears with the power supply unit 0 installed, check that the unit is properly installed.
Off Line
Power is not reaching the power supply unit 0. Check the AC inputs.
Alarm Detected.
A power supply error was detected. Replace the unit.
Displays the status of power supply unit 1.The messages and actions to take are the same as those described for power supply unit 0.
Displays status of the CPU board supply voltages.
Voltage Good
The voltage supplies are within normal operating range.
VDP: Out of range. (xx)
A VDP voltage error was detected. Contact the sales representative.
VDE: Out of range. (xx)
A VDE voltage error was detected. Contact the sales representative.
VDR: Out of range. (xx)
A VDR voltage error was detected. Contact the sales representative.
VDD: Out of range. (xx)
A VDD voltage error was detected. Contact the sales representative.
VDN: Out of range. (xx)
A VDN voltage error was detected. Contact the sales representative.
1.5V : Out of range. (xx)
A 1.5V power supply error was detected on the CPU board. Contact the sales representative.
3.3V : Out of range. (xx)
A 3.3V power supply error was detected on the CPU board. Contact the sales representative.
12V : Out of range. (xx)
A 12V power supply error was detected on the CPU board. Contact the sales representative.
3.3V (I/F): Out of range. (xx)
A 3.3V power supply error was detected on the switch board.
Contact the sales representative.
12V (I/F): Out of range. (xx)
A 12V power supply error was detected on the switch board.
Contact the sales representative.
239/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Fan
XFP
Rear Fan-0
Rear Fan-1
PWR-0 Fan (fan installed in power supply unit 0)
Displays the status of the fans. good (normal-speed)
The fan is working at a normal speed. good (high-speed)
The fan is working at a high speed.
Removed
The fan was removed.
Check that the fan is installed.
Speed is below the Low Limit. (xx yy)
The fan speed is below the low limit. Replace the fan unit.
Messages other than those above
The fan is not working properly. Replace the fan unit.
Status of rear fan 1
The messages and actions to take are the same as those described for Rear Fan-0
Good
The fan is working properly.
Speed is below the Low Limit. (xx yy)
The fan speed is below the low limit. It is also displayed when the
PSU is removed. Replace the power supply unit if the message is displayed even though it is working properly.
PWR-1 Fan (fan installed in power supply unit 1) Status of the fan installed in power supply unit 1
The messages are the same as those described for PWR-0 fan. port xx (status of port xx)
(The number of ports are depend on the device.)
Displays the vender name, PHY type and status for each XFP.
The vender name is read from the XFP device while the PHY type is based of "XFP MSA4.5".
Good
The XFP is working properly.
Low Power
The XFP is in power down mode.
Alarm (xx)
An XFP alarm was detected. If high temperature alarm is detected, the device shut down the XFP. Check the XFP insertion and the temperature around the XFP. If the same message is displayed after taking appropriate action, note the message contents and contact the sales representative.
PHY Device Error
An XFP access error occurred. Check the XFP insertion. If the same message is displayed after taking appropriate action, note the message contents and contact the sales representative.
No messages
An XFP was removed. If this message appears with the XFP in the slot, check that it is properly installed.
240/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
6.1.2 Verifying System Status
Verify the system status by entering the "
show system information " command in the operator EXEC mode or in the
administrator EXEC mode.
The following example shows the information that is displayed when the "
show system information " command is entered.
xg# show system information
System Information 2007/02/22-21:06:11
=======================================
System Name (hostname) : xg
System Location : (none)
System Contact : (none)
Default Banner : XG2000 E10L11 Z01
Startup Time : 2007/02/22-19:28:24
Startup-config Modified: 2007/02/22-19:54:01
Firmware Information
Firmware[1] : E10L10 Z01 2007/01/21-18:42:52
Updated Time : 2007/01/21-22:08:12
Firmware[2] : E10L11 Z01 2007/02/22-19:27:12
Updated Time : 2007/02/23-10:57:53
Current Firmware : [2]
Next Startup Firmware : [2]
Boot Loader : E10L10 Z01
Timezone : gmt +0900
(Next Boot) : gmt -800
Summer-Time : (none)
(Next Boot) : M4.1.0/0200 M10.5.0/0200 0100
RS232C Baud-Rate : 9600
Management LAN Information
MAC Address : 0080.17c2.0500
IP Address/Mask : 192.168.41.22/24
Default Gateway : 192.168.41.1
DNS Server : 192.168.77.20
Domain Name : abc.efg.com
System Load Information
CPU Used Ratio : 1%
Memory Used Size : 36,429,824 bytes (28%)
Check the version of firmware. Verify the system status based on CPU load and memory usage.
6.1.3 Reviewing Log Messages
Log messages from the device are classified into 4 levels -- CRITICAL, ERROR, WARNING, and INFO -- in accordance with the severity of events.
To display event logs, run the "
show log " command in the operator EXEC mode or in the administrator EXEC mode.
241/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
6.1.3.1 Format of Log Message
An example of the format of a log message displayed by the "
show log " command is shown below.
xg# show log info latest 1
May 25 22:08:33 xghost xgsh: XG INFO[P4001]: cmd-exec[3388]: show log info latest 1
| | | | | | | |
Month
|
HH:MM:SS | Function name Severity | Message text
Day Host name Message ID
for the device
Month
Displays the date (month) of the event.
Day
Displays the date (day) of the event.
HH:MM:SS
Displays the time (hours:minutes:seconds) of the event.
Host name of the device
Displays the host name.
Function name
Indicates the function name.
Severity
Indicates the severity of the message.
− CRITICAL
The system encountered a serious condition that prevented it from continuing its operation. Take appropriate action in response to this message.
− ERROR
Does not stop system operation but some functions are inoperable. Take appropriate action in response to this message.
− WARNING
An error or critical condition was detected, but it does not affect normal operation of the device. Determine whether an action must be taken by examining the message.
− INFO
A message provides information about the system status. No action is necessary.
Message ID
Message ID is displayed in a form that begins with an "S" or "P".
− S
A message that receives SNMP trap notification.
− P
A message that does not receive SNMP trap notification.
− Message number
Displays a unique number used to identify a message within the device.
Verify the meaning of the message and actions to take based on the message number.
Message text
Displays message text.
6.1.3.2 Reviewing Fault Logs
If a fault occurred, review the fault log to check fault messages (CRITICAL, ERROR, or WARNING).
To review fault logs, enter the "
show log " command in the operator EXEC mode or in the administrator EXEC mode. For the
meaning of messages and actions to take for the errors, refer to "
Appendix A.2 List of Event Logs ".
The following examples show the information that is displayed when the "
show log " command is entered.
xg# show log critical
Aug 22 03:33:51 xg kernel: XG CRITICAL[S1000]: Abnormal reset occurred (WatchDog Reset: code=1)
Aug 22 03:33:51 xg kernel: XG CRITICAL[S1900]: Core dumped 359 xg# show log error
Aug 22 03:33:51 xg env: XG ERROR[S0101]: Internal Temperature is out of rage. (65)
Aug 22 03:33:51 xg env: XG ERROR[S0115]: port 1 is not present. xg# show log warning
Aug 22 03:33:51 xg env: XG WARNING[S0109]: Front Fan-1 Speed is below the Low Limit. (2150 6675)
Aug 22 03:33:51 xg npm: XG WARNING[S3005]: port 1 detected port security violation.
Aug 22 03:33:51 xg npm: XG WARNING[S3202]: Received IGMP packet without IP header.
242/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
6.1.3.3 Verifying the Device Status Change
To verify changes in the device status, review INFO log messages.
Enter the "
refer to "List of System Logs". The following examples show the information that is displayed when the "
entered. xg# show log info
Aug22 10:07:57 xg xgsh: XG INFO[P4001]: cmd-exec[893]: show system information
Aug22 10:08:01 xg xgsh: XG INFO[P4002]: cmd-result[893]: success
Aug22 10:08:01 xg xgsh: XG INFO[P4001]: cmd-exec[893]: show spanning-tree
Aug22 10:08:01 xg xgsh: XG INFO[P4002]: cmd-result[893]: success
Aug22 10:08:02 xg xgsh: XG INFO[P4001]: cmd-exec[893]: show remote-host
Aug22 10:08:02 xg xgsh: XG INFO[P4002]: cmd-result[893]: success
Aug22 10:08:34 xg ntp : XG INFO[P8602]: time server 192.168.41.1 offset -0.000543 sec
Aug22 10:08:34 xg xgsh: XG INFO[P4002]: cmd-result[893]: success
Aug22 10:10:34 xg ntp : XG INFO[P8602]: time server 192.168.41.1 offset -0.000660 sec
Aug22 10:45:32 xg xgsh: XG INFO[P4001]: cmd-exec[592]: exit
Aug22 10:45:32 xg xgsh: XG INFO[P4002]: cmd-result[592]: success
Display log for each component
To display a log associated with a specific component only, specify the name of that component with "| include " after entering "
In the following example, the CLI displays only messages that include "cmd-exec". xg# show log info | include cmd-exec
Aug22 10:07:57 xg xgsh: XG INFO[P4001]: cmd-exec[893]: show system information
Aug22 10:08:01 xg xgsh: XG INFO[P4001]: cmd-exec[893]: show spanning-tree
Aug22 10:08:02 xg xgsh: XG INFO[P4001]: cmd-exec[893]: show remote-host
Aug22 10:45:32 xg xgsh: XG INFO[P4001]: cmd-exec[592]: exit
243/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
6.2 Uploading/Downloading a Configuration File
The configuration file, generated in the device, can be uploaded to a TFTP server. Also, when an uploaded configuration file is downloaded from a TFTP server, the configuration of the device can be restored.
This section describes the procedures involved in uploading/downloading a configuration file.
6.2.1 Preparing the TFTP Server
Before uploading and/or downloading configuration files using a TFTP server, carry out the following procedures.
Check that the management LAN and the workstation or other machine operating as the TFTP server is set up appropriately. Verify communication between the TFTP server and the management LAN is error-free.
Check that the access privilege of the root directory is readable/writable in the TFTP server.
When downloading the configuration file, check that the configuration file uploaded to the TFTP server is located in the correct directory.
6.2.2 Uploading a Configuration File
This section describes the procedure for uploading the configuration (startup-config) file to a TFTP server.
1. After logging into the device, use the "
enable " command to switch to administrator EXEC mode.
xg> enable
2. Upload the configuration (startup-config) file to the TFTP server "host1" as filename "start_conf". xg# show startup-config | tftp host1 start_conf
3. Check that the size of configuration file uploaded to a TFTP server is the same as that of the source configuration file.
6.2.3 Downloading a Configuration File
This section describes the procedure for downloading the configuration file from a TFTP server to the device as the startup-config file.
1. After logging into the device, use the "
enable " command to switch to administrator EXEC mode.
xg> enable
2. Using the "
copy tftp startup-config " command, download the saved file from the TFTP server to the device.
In the following example, "start_conf" file saved on the TFTP server "host1" is downloaded to the startup-config file in the device. xg# copy tftp host1 start_conf startup-config
3. Using the "
show startup-config " command, check that the contents of the startup-config changed.
Using the "
the startup-config file changed. xg# show startup-config xg# show system information
System Information 2007/01/22-15:02:54
=======================================
System Name (hostname) : xg
System Location : (none)
System Contact : (none)
Default Banner : XG2000 E10L10 Z01
Startup Time : 2007/01/22-19:28:24
Startup-config Modified: 2007/01/22-19:54:01
← Last updated date and time
4. To enable the downloaded startup-config, reboot the device using the "
xg# reset
Do you restart system? (y/n) :
← A confirmation message is displayed.
244/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
6.3 Updating Firmware
The device can hold two versions of firmware. If a firmware update is performed, the inactive firmware will be updated. The device automatically uses the new firmware (updated version) during reboot after the firmware update. If the switch fails to start the new firmware, it automatically uses the old version (the one that was not updated). If problems occur with the new version, the old version can be manually selected.
First, prepare and update the firmware.
Then, select the firmware to use.
6.3.1 Updating Firmware
This section describes the procedure involved when updating firmware using a TFTP server.
1. After logging into the device, use the "
enable " command to switch to administrator EXEC mode.
xg> enable
2. Using the "
update-system " command, perform a firmware update.
If a firmware update is performed, the inactive firmware will be updated.
In the following example, the firmware is updated using the firmware file "XF10100" stored on the TFTP server "host1". xg# update-system tftp host1 XF10100
3. Upon successful completion of the firmware update, verify the version number of the updated firmware (E#/L#)
When the firmware update completes successfully, the updated firmware selection number is displayed in "Next
Startup Firmware". xg# show system information
Firmware Information
Firmware[1] : E10L10 Z01 2007/01/21-18:42:52
Updated Time : 2007/01/21-22:08:12
Firmware[2] : E10L11 Z01 2007/02/22-19:27:12
Updated Time : 2007/02/23-10:57:53
↑
Current Firmware : [1]
Displays the status of update.
Next Startup Firmware : [2]
4. Upon completion of the firmware update, reboot the device using the "
xg# reset
Do you restart system? (y/n) :
← A confirmation message is displayed.
If the reboot (starting the new firmware) fails, the old version is automatically selected and booted. If this is the case, the following message is output to the log.
XG WARNING[S7520]: init-firmup: Booting new firmware failed. Old firmware '%1$' is now running.
Explanation
Old firmware was run because the new updated firmware can not successfully initialize.
[[Inserted string]]%1$: Firmware version information
245/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
6.3.2 Selecting Firmware
This section describes the procedures for selecting the firmware to use.
1. After logging into the device, use the "
enable " command to switch to administrator EXEC mode.
xg> enable
2. Using the "
show system information " command, check the status of the firmware.
Note the firmware information (Firmware[1] and [2]), the currently active firmware (Current
Firmware), and firmware that will run the next time (Next Startup Firmware) the switch is rebooted. xg# show system information
Firmware Information
Firmware[1] : E10L10 Z01 2007/01/21-18:42:52
Updated Time : 2007/01/21-22:08:12
Firmware[2] : E10L11 Z01 2007/02/22-19:27:12
Updated Time : 2007/02/23-10:57:53
Current Firmware : [2]
Next Startup Firmware: [2]
Boot Loader : E10L10 Z01
3. Using the "
boot-system " command, change the Next Startup Firmware image.
Using the "
show system information " command again, check that the "Next Startup Firmware"
changed. xg# boot-system 1 xg# show system information
Firmware Information
Firmware[1] : E10L10 Z01 2007/01/21-18:42:52
Updated Time : 2007/01/21-22:08:12
Firmware[2] : E10L11 Z01 2007/02/22-19:27:12
Updated Time : 2007/02/23-10:57:53
Current Firmware : [2]
Next Startup Firmware: [1]
4. Reboot the device using the "
xg# reset
Do you restart system? (y/n) :
← A confirmation message is displayed.
246/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
6.4 Extracting of Maintenance Information
If a fault occurred, maintenance information may be requested by the device sales representative to investigate the cause of the fault. This section provides procedures for extracting maintenance information.
Depending on the situations shown below, extract maintenance information using the described procedures.
System/Subsystem failure
If an unrecoverable error occurred in the device's system or subsystem, the system automatically saves maintenance information and restarts the system operations.
System loop
If the system entered an endless loop and CLI command entry is not accessible, use the "dump" switch on the front panel to save maintenance information and restart the system.
The device malfunctions
If a function configured for the device malfunctions, save maintenance information using the Extract Information command.
6.4.1 Procedure for Extracting Maintenance Information when a System
/Subsystem Failure Occurred
This section describes the procedures for extracting maintenance information when a system or subsystem failure occurred.
A system/subsystem failure occurred.
If an unrecoverable error, including a system or subsystem failure, occurred in the device, the system automatically saves maintenance information and restarts the system operations.
If a system failure occurred, a system dump file and a process dump file are generated.
System logs and SNMP traps
After the system restarts, a system log entry is generated to indicate that a system/subsystem failure generated a dump file. Configuring an SNMP trap in advance causes the system/subsystem failure to be reported to a system administrator.
Viewing maintenance information history
Using the "
show maintenance " command, check that the maintenance information was saved.
xg# show maintenance
Maintenance Information 2007/01/22-15:55:20
==================================================
NO Type Occurred Time
--- -------------------------- -------------------
1 system dump 2007/01/22-18:21:23
2 process dump 2007/01/22-20:57:58
==================================================
The "
show maintenance " command displays one of the following types of maintenance information
in "Type".
− system dump
System dump recorded when a system failure occurred.
− system dump(dump switch)
Forced system dump caused by the "dump" switch.
− system dump(machine check)
System dump triggered by a hardware machine check.
− process dump
Process dump generated when a failure occurred in a subsystem.
Extracting maintenance information
Using the "
tftp put-maintenance " command, forward the maintenance information to an external
TFTP server.
Contact the sales representative.
247/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
6.4.2 Procedure for Extracting Maintenance Information when an endless System Loop Occurred
This section describes the procedures for extracting maintenance information when an endless system loop occurs.
A system loop occurred.
If a CLI command entry is not accepted for an extended period of time, a system loop may exist.
Press the "dump" switch on the device's front panel.
The maintenance information is automatically saved when the "dump" switch is pressed, and then the system restarts.
***Reporting system logs on dump outputs/Reporting traps
After the system retorts, a system log is issued to indicate that a forced system dump was generated. Configuring an SNMP trap in advance causes a trap indicating the occurrence of a system failure to be reported to a system administrator.*** Use previously edited bullet***
Viewing maintenance information history
Using the "
show maintenance " command, check that the maintenance information was saved.
xg# show maintenance
Maintenance Information 2007/01/22-15:55:20
==================================================
NO Type Occurred Time
--- -------------------------- -------------------
1 system dump(Dump switch) 2007/01/22-18:21:23
==================================================
The maintenance information that was saved by the "dump" switch is represented by "system dump(Dump switch)" under the "Type" column.
Extracting maintenance information
Using the "
tftp put-maintenance " command, forward the maintenance information to a TFTP
server.
Contact the sales representative.
6.4.3 Procedure for Extracting Maintenance Information when a
Malfunction Occurs
This section describes the procedures for extracting maintenance information when a malfunction occurs.
A malfunction occurred.
When a function configured for the device fails to operate properly, the maintenance information can be extracted.
Using the "
save maintenance " command, save the maintenance information.
Viewing maintenance information history
Using the "
show maintenance " command, check that the maintenance information was saved.
xg# show maintenance
Maintenance Information 2007/01/22-15:55:20
==================================================
NO Type Occurred Time
--- -------------------------- -------------------
1 system state 2007/01/22-20:58:14
==================================================
The maintenance information that was saved by the "
save maintenance " command is represented
by "system state" under the "Type" column.
Extracting maintenance information
Using the "
tftp put-maintenance " command, forward the maintenance information to a TFTP
server.
Contact the sales representative.
248/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Chapter 7 Troubleshooting
This chapter describes how to solve problems that might be encountered when using the device.
249/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
7.1 Restoring Factory Defaults
7.1.1 Resetting startup-config to Factory Defaults
To reset all settings in the device's startup-config file to the factory defaults:
Using the "reset factory-default" command, reset the contents of the startup-config file to the factory defaults.
When the command is executed, a message appears requesting confirmation of the restart. xg# reset factory-default
Do you restart system with setting to factory-default? (y/n) :
← A confirmation message is displayed.
If the response is "y" or "Y", the contents of the startup-config file are reset to the factory defaults and the system restarts. To cancel the process, respond to this question with any keys other than "y " and "Y".
The login password is not stored in the startup-config file. To change the login password, the "password" command must be used.
Timezone and summer time settings will be re-initialized. After restarting the system set the timezone and summer time settings as necessary.
7.1.2 Selecting the Alternate Firmware Image
When the system successfully starts up, the firmware image to be run can be selected by following the procedure described in
"
If the system fails to start up, select the alternate firmware for reboot by executing the following sequence immediately after turning on the device.
Connect the device to an active serial terminal.
Turn on the device.
Hold down the [#] key and the following message will appear on the serial terminal screen.
Preparing to boot
At the XG_LOADER> prompt, type "boot", and then specify the firmware image number to run.
XG_LOADER> boot { 1 | 2 }
To determine the firmware number to specify, use the "firminfo" command. The "firminfo" command allows checking the firmware versions (E#/L#) and the number that corresponds to the firmware image to run.
For the firmware versions (E#/L#), check the "Firm EL of region 1" and "Firm EL of region
2" fields. For the number that corresponds to the firmware image to run, check the number that appears in the "Region being used now" field. Specify the other firmware number in the
"boot" command.
In the following example, 2 is specified for the firmware number in the "boot" command (1 is assigned to the firmware image that is to be run).
XG_LOADER> firminfo
Firm EL of region 1 : 10.11 Z01 (1121772145)
Firm EL of region 2 : 10.10 Z01 (1121770019)
Boot loader version : 10.10 Z01
Region being used now : 1
Region to be used next : 1
Status flag of region 1: CURRENT FIRM
Status flag of region 2: OLD FIRM
250/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
7.1.3 Restoring Factory Defaults
If the system still fails to start up with another firmware image selected, perform the following procedure to restore the device to factory defaults.
(Step 1)
Connect the device to a serial terminal.
Turn on the device.
Hold down the [#] key and the following message will appear on the serial terminal screen.
Preparing to boot
At the XG_LOADER> prompt, enter the following command.
XG_LOADER> boot init
When the above command is executed, the startup-config, time zone and summer time settings, and password of the device are restored to the factory defaults and the system restarts,
If the system still fails to start up, perform the following procedure.
(Step 2)
Turn off the device and on again.
Hold down the [#] key and the following message will appear on the serial terminal screen.
Preparing to boot
At the XG_LOADER> prompt, enter the following command.
XG_LOADER> clear setup
When Step 2 is executed following Step 1, all settings in the device are re-initialized.
The system then restarts. Entering the "clear setup" command displays the following message:
Are you sure to continue [y/<n>]?
Explanation
If the response is "y" or "Y", the device's all settings are reset to the factory defaults and the system restarts. To cancel the process, respond to this message with any keys other than "y" and "Y".
The following message appears while the system is rebooting. Note that it does not indicate a failure if it appears after the command was executed.
*** Warning - bad CRC, using default environment
Explanation
The boot loader's system startup data area was initialized.
XG WARNING[S7521]: init-firmup: Firmware update information is initialized for region %1$.
Explanation
The firmware update information area was initialized.
[[Inserted string]]%1$: Firmware number
Timezone and summer time settings will be re-initialized. After restarting the system, set the timezone and summer time settings as necessary.
251/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
APPENDICES
252/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Appendix A Event Logs
This appendix describes event logs that are extracted from the device, including message IDs, severities, message content details, and actions to take.
The severities of the event logs are classified into 4 levels -- CRITICAL, ERROR, WARNING, and INFO.
To display event logs, run the "
show log " command in the operator EXEC mode or in the administrator EXEC mode.
A.1 Overview of Event Logs
This section summarizes messages that are written to logs.
The message ID format is defined as described in "
− Message numbers, each starting with an "S", are events that received SNMP trap notifications
− Message numbers, each starting with a "P", are events that did not receive SNMP trap notifications
The following table lists the abbreviated function names and message numbers.
Abbreviated function name
Message number range Description
env kernel swc npm
0 - 999
1000 - 1999
2000 - 2999
3000 - 3299
Health monitoring
Basic control
Layer 2 basic control
Network protocol control clim xgsh rstp lacp sys update snmp ntp
3300 - 3999
4000 - 4499
4500 - 4999
5000 - 5499
7400 - 7499
7500 - 7999
8500 - 8599
8600 - 8699
Basic CLI control
CLI command history
Rapid Spanning Tree (RSTP) control
LACP control
Maintenance support function
Firmware update
SNMP control
NTP (Network Time Protocol) control
253/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
A.2 List of Event Logs
This section provides an explanation of message contents and actions to take for the associated message ID and severity in ascending numerical order. There is no solution provided for messages that do not required action.
A.2.1 env (Health Monitoring: 0-999)
Message ID
Severity
S0101
ERROR
S0102
WARNING
S0104
WARNING
P0105
INFO
S0106
INFO
P0107
INFO
S0108
ERROR
Message/Explanation/Solution
%1$ Temperature is out of range. (%2$ %3$)
Explanation
The temperature is out range for normal operation.
[[Inserted string]]%1$: Location of detected temperature error.
Internal: The temperature inside the chassis
[[Inserted string]]%2$, %3$: Temperature value
Solution
Confirm the following checks on the device:
Check that the air vent is not blocked.
Check that the temperature of the switch environment is within the limits specified.
If there is no air vent blockage and the ambient temperature is within specifications, note the message contents and contact the sales representative.
PWR-%1$ ALARM is detected.
Explanation
A power supply error was detected.
[[Inserted string]]%1$: Power supply unit number
Solution
Replace the power supply unit.
PWR-%1$ is Off Line.
Explanation
AC power is not reaching one of the power supply units.
[[Inserted string]]%1$: Power supply unit number
Solution
Check the AC cable and plugs.
PWR-%1$ is On Line.
Explanation
Power was restored to the power supply unit.
[[Inserted string]]%1$: Power supply unit number
PWR-%1$ is Removed.
Explanation
The power supply unit was removed.
[[Inserted string]]%1$: Power supply unit number
Solution
If this message is received at times other than during hot swap, check for proper installation.
PWR-%1$ is Inserted.
Explanation
A power supply unit was installed.
[[Inserted string]]%1$: Power supply unit number
Solution
If this message is received at times other than during hot swap, check for proper installation.
%1$ is out of range. (%2$)
Explanation
A supply voltage error was detected.
[[Inserted string]]%1$: Displays the types of power supply fault(s) (VDP/VDE/VDR/VDD/VDN/3.3V
Main/12V/3.3V(IF)/12V(IF)).
[[Inserted string]]%2$: Value that represents the power supply fault
Solution
Note the message contents and contact the sales representative.
254/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Message ID
Severity
S0109
WARNING
Message/Explanation/Solution
%1$ Speed is below the Low Limit. (%2$ %3$)
Explanation
The speed of a fan is below limit.
[[Inserted string]]%1$: Displays the location of the detected fan speed error.
Rear Fan-0: Rear fan 0
Rear Fan-1: Rear fan 1
P0110
INFO
PWR-0 Fan: Fan installed in power supply unit 0
PWR-1 Fan: Fan installed in power supply unit 1
[[Inserted string]]%2$, %3$: Fan speed.
Solution
Replace the fan unit.
%1$ Speed is good.
Explanation
The speed of a fan returned to normal.
[[Inserted string]]%1$: Identifies the fan whose normal speed was restored.
Rear Fan-0: Rear fan 0
Rear Fan-1: Rear fan 1
S0111
INFO
P0112
INFO
PWR-0 Fan: Fan installed in power supply unit 0
PWR-1 Fan: Fan installed in power supply unit 1
%1$ is Removed.
Explanation
A fan was removed.
[[Inserted string]]%1$: Identifies the fan removed.
Rear Fan-0: Rear fan 0
Rear Fan-1: Rear fan 1
%1$ is Inserted.
Explanation
A fan was installed.
[[Inserted string]]%1$: Identifies the fan installed.
Rear Fan-0: Rear fan 0
Rear Fan-1: Rear fan 1
P0113
INFO port %1$ Plug-In.
Explanation
An XFP was installed.
[[Inserted string]]%1$: The port number of the installed XFP
P0114
INFO port %1$ Plug-Out.
Explanation
An XFP was removed.
[[Inserted string]]%1$: The port number of the XFP removed
P0120
INFO
Fan Speed was changed into high speed.
Explanation
The fan speed changed from normal to high speed.
P0121
INFO
S0122
ERROR
S0123
WARNING
Fan Speed was changed into normal speed.
Explanation
The fan speed changed from high to normal speed. port %1$ PHY Alarm is detected. (%2$)
Explanation
An XFP alarm was detected. If a high temperature is detected, the device will shut down the XFP.
[[Inserted string]]%1$: Number assigned to the port that detected the alarm.
[[Inserted string]]%2$: Displays additional information on the alarm.
Solution
Check the XFP connection and temperature around the XFP.
If the same message is displayed after taking appropriate action, note the message contents and contact the sales representative. port %1$ PHY Warning is detected. (%2$)
Explanation
An XFP warning was detected.
[[Inserted string]]%1$: Number assigned to the port that detected the warning.
[[Inserted string]]%2$: Displays additional information on the warning.
Solution
The XFP is still good, but a failure may occur if the condition persists. Check the XFP connection and temperature around the XFP.
If the same message is displayed after taking appropriate action, note the message contents and contact the sales representative.
255/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Message ID
Severity
S0124
Info
S0125
CRITICAL
Message/Explanation/Solution
Internal Temperature is high. (%1$ %2$)
Explanation
The temperature is high. The system will be shut down if the temperature rises.
[[Inserted string]]%1$, %2$: Temperature value
Solution
Perform the following checks on the device:
Check that the air vent is not blocked.
Check the temperature of the switch environment is within the limits specified.
Shutdown the system because of high temperature alarm. (%1$ %2$)
Explanation
The system was shut down because of high temperature alarm.
[[Inserted string]]%1$, %2$: Temperature value
Solution
Perform the following checks on the device:
Check that the air vent is not blocked.
Check the temperature of the switch environment is within the limits specified.
If the message is displayed even though the device was properly installed, note the message contents and contact the sales representative.
A.2.2 kernel (Basic Control: 1000-1999)
Message ID
Severity
S1000
CRITICAL
Message/Explanation/Solution
S1001
CRITICAL
P1100
INFO
P1101
INFO
S1900
CRITICAL
S1950
CRITICAL
Abnormal reset occurred (WatchDog Reset: code=%1$)
Explanation
The fault monitor control detected an error and rebooted the device.
[[Inserted string]]%1$: Additional information that indicates the cause of the reset.
Solution
Obtain maintenance information using the "
tftp put-maintenance " command after restarting the system then
note the message content before contacting the sales representative.
MAC address in EEPROM is invalid.
Explanation
An error occurred in the device that stores the device's MAC addresses.
Solution
Note the message contents and contact the sales representative.
%1$: config: auto-negotiation on, %2$
Explanation
Management LAN auto-negotiation is being performed.
[[Inserted string]]%1$: Name of target network interface
[[Inserted string]]%2$: Displays supported features (speed and duplex).
%1$: status: link %2$
Explanation
The link status of the management LAN changed.
[[Inserted string]]%1$: Name of target network interface
[[Inserted string]]%2$: Displays details of the current link state.
Core dumped %1$
Explanation
A critical firmware error was detected and a process dump was output.
[[Inserted string]]%1$: Process number
Solution
Obtain maintenance information using the "
tftp put-maintenance " command then take note of the message
content before contacting the sales representative.
Oops: %1$, sig: %2$
Explanation
An unhandled exception caused a system panic.
[[Inserted string]]%1$: Details about error
[[Inserted string]]%2$: Signal number
Solution
Note this message and those displayed above and below it then contact the sales representative. This type of message may not be recorded in the log.
256/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Message ID
Severity
S1951
CRITICAL
S1952
CRITICAL
S1960
ERROR
S1970
WARNING
Message/Explanation/Solution
Kernel panic: %1$
Explanation
The software detected a status error during processing and raised a system panic.
[[Inserted string]]%1$: Details about error
Solution
Note this message and those displayed above and below it then contact the sales representative. This message type may not be recorded in the log.
DRAM MBE detected.
Explanation
The software detected a DRAM multi-bit error or too many single bit errors(256 times or more every 2 seconds).
The system is rebooted automatically.
Solution
Note this message and those displayed above and below it then contact the sales representative. This message type may not be recorded in the log.
Too many DRAM SBE detected.(%1$)
Explanation
The software detected too many DRAM single bit errors. No more events will be logged.
[[Inserted string]]%1$: Details about error
Solution
The device supports single bit ECC, so the error is corrected. But a failure may occur if the error happens again after a system reset. Note this message and those displayed above and below it then contact the sales representative. This message type may not be recorded in the log.
DRAM SBE detected.
Explanation
The software detected DRAM single bit error.
Solution
The device supports single bit ECC, so the error is corrected.
A.2.3
S2104
ERROR
S2105
ERROR
S2106
ERROR
swc (Layer 2 Basic Control: 2000-2999)
Message ID
Severity
S2103
ERROR
Message/Explanation/Solution
Output Queue MBE detected. %1$
Explanation
An uncorrectable error was detected in the switch chip.
[[Inserted string]]%1$: Supplementary code for the error
Solution
Note the message contents and contact the sales representative.
Disabling port %1$.
Explanation
A failure occurred on the switch chip communication port. The port was disabled.
[[Inserted string]]%1$: Port number
Solution
Note the message contents and contact the sales representative.
Tag Memory MBE detected. %1$
Explanation
An uncorrectable error was detected in the switch chip.
[[Inserted string]]%1$: Port number
Solution
Note the message contents and contact the sales representative.
Input Buffer Tag Memory MBE detected. %1$
Explanation
An uncorrectable error was detected in the switch chip.
[[Inserted string]]%1$: Port number
Solution
Note the message contents and contact the sales representative.
257/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Message ID
Severity
S2107
ERROR
S2110
ERROR
S2111
ERROR
S2112
ERROR
S2200
WARNING
S2201
WARNING
S2202
WARNING
S2203
WARNING
S2204
WARNING
Message/Explanation/Solution
Too Many Input Queue Tag Memory MBE Errors. LOG Disabled.
Explanation
An uncorrectable error was repeatedly detected in the switch chip. Logging for this event is disabled.
Solution
Note the message contents and contact the sales representative.
CM Buffer MBE detected. %1$
Explanation
An uncorrectable error was detected in the switch chip.
[[Inserted string]]%1$: Supplementary code for the error
Solution
Note the message contents and contact the sales representative.
Drop Queue MBE detected. %1$
Explanation
An uncorrectable error was detected in the switch chip.
[[Inserted string]]%1$: Supplementary code for the error
Solution
Note the message contents and contact the sales representative.
ME Halt detected. %1$
Explanation
An uncorrectable error was detected in the switch chip.
[[Inserted string]]%1$: Supplementary code for the error
Solution
Note the message contents and contact the sales representative.
MAC Table Error detected. %1$
Explanation
An uncorrectable error was detected in the MAC address management table.
[[Inserted string]]%1$: Supplementary code for the error
Solution
Note the message contents and contact the sales representative.
Too Many MAC Table Error. Reset Switch LSI.
Explanation
An uncorrectable error was repeatedly detected in the MAC address management table. The switch chip was reset.
Solution
Note the message contents and contact the sales representative.
VLAN Table MBE detected. %1$
Explanation
An uncorrectable error was detected in the VLAN management table.
[[Inserted string]]%1$: Supplementary code for the error
Solution
Note the message contents and contact the sales representative.
VLAN Table SBE detected. %1$
Explanation
An uncorrectable error was detected in the VLAN management table. It is automatically corrected by hardware.
[[Inserted string]]%1$: Supplementary code for the error
Solution
If the same message reappears after restarting the switch, note the message contents and contact the sales representative.
Too Many VLAN Table MBE Errors. Reset Switch LSI.
Explanation
An uncorrectable error was repeatedly detected in the VLAN management table. The switch chip was reset.
Solution
If the same message reappears after restarting the switch, note the message contents and contact the sales representative.
258/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Message ID
Severity
S2205
WARNING
S2206
WARNING
S2207
WARNING
S2208
WARNING
S2209
WARNING
S2210
WARNING
S2211
WARNING
S2212
WARNING
S2213
WARNING
S2214
WARNING
Message/Explanation/Solution
Too Many VLAN Table SBE Error. Log Disabled.
Explanation
A correctable error was repeatedly detected in the switch chip. Logging for this event is disabled.
Solution
Note the message contents and contact the sales representative.
Multicast State Table Error detected. %1$
Explanation
An uncorrectable error was detected in the switch chip.
[[Inserted string]]%1$: Supplementary code for the error
Solution
Note the message contents and contact the sales representative.
Too Many MST Errors. Reset Switch LSI.
Explanation
An uncorrectable error was repeatedly detected in the switch chip. The switch chip was reset.
Solution
Note the message contents and contact the sales representative.
Stream Memory Tag MBE detected. %1$
Explanation
An uncorrectable error was detected in the switch chip.
[[Inserted string]]%1$: Supplementary code for the error
Solution
Note the message contents and contact the sales representative.
Too Many SMT MBE Errors. LOG Disabled.
Explanation
An uncorrectable error was repeatedly detected in the switch chip. Logging for this event is disabled.
Solution
If the same message reappears after restarting the switch, note the message contents and contact the sales representative.
Stream Memory Tag SBE detected. %1$
Explanation
A correctable error was detected in the switch chip. It is automatically corrected by hardware.
[[Inserted string]]%1$: Supplementary code for the error
Solution
If the same message reappears after restarting the switch, note the message contents and contact the sales representative.
Too Many SMT SBE Errors. LOG Disabled.
Explanation
A correctable error was repeatedly detected in the switch chip. Logging for this event is disabled.
Solution
Note the message contents and contact the sales representative.
Output Queue SBE detected. %1$
Explanation
A correctable error was detected in the switch chip. It is automatically corrected by hardware.
[[Inserted string]]%1$: Supplementary code for the error
Solution
Note the message contents and contact the sales representative.
Too Many Output Queue SBE Errors. LOG Disabled.
Explanation
A correctable error was repeatedly detected in the switch chip. Logging for this event is disabled.
Solution
Note the message contents and contact the sales representative.
Tag Memory SBE detected. %1$
Explanation
A correctable error was detected in the switch chip. It is automatically corrected by hardware.
[[Inserted string]]%1$: Supplementary code for the error
Solution
If the same message reappears after restarting the switch, note the message contents and contact the sales representative.
259/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Message ID
Severity
S2215
WARNING
S2216
WARNING
S2217
WARNING
S2218
WARNING
S2219
WARNING
S2220
WARNING
S2221
WARNING
S2222
WARNING
S2223
WARNING
Message/Explanation/Solution
Too Many Tag Memory SBE Errors. LOG Disabled.
Explanation
A correctable error was repeatedly detected in the switch chip. Logging for this event is disabled.
Solution
Note the message contents and contact the sales representative.
Input Buffer Tag Memory SBE detected. %1$
Explanation
A correctable error was detected in the switch chip. It is automatically corrected by hardware.
[[Inserted string]]%1$: Supplementary code for the error
Solution
If the same message reappears after restarting the switch, note the message contents and contact the sales representative.
Too Many Input Queue Tag Memory SBE Errors. LOG Disabled.
Explanation
A correctable error was repeatedly detected in the switch chip. Logging for this event is disabled.
Solution
Note the message contents and contact the sales representative.
MAC address learning failed.
Explanation
Failed to learn the MAC address.
Solution
Delete the unused static MAC address. Since MAC addresses are managed with a hashing algorithm, a message stating the address cannot be registered may be displayed even though the number of addresses registered is less than the number that can be registered. If the message is displayed even though no static
MAC address is unregistered, note the message contents and contact the sales representative.
Drop Queue SBE detected. %1$
Explanation
A correctable error was detected in the switch chip. It is automatically corrected by hardware.
[[Inserted string]]%1$: Supplementary code for the error
Solution
If the same message reappears after restarting the switch, note the message contents and contact the sales representative.
Too Many Drop Queue SBE Errors. LOG Disabled.
Explanation
A correctable error was repeatedly detected in the switch chip. Logging for this event is disabled.
Solution
Note the message contents and contact the sales representative.
MAC Table SBE detected. %1$
Explanation
A correctable error was detected in the switch chip. It is automatically corrected by hardware.
[[Inserted string]]%1$: Supplementary code for the error
Solution
If the same message reappears after restarting the switch, note the message contents and contact the sales representative.
Too Many MAC Table SBE Error. LOG Disabled.
Explanation
A correctable error was repeatedly detected in the switch chip. Logging for this event is disabled.
Solution
Note the message contents and contact the sales representative.
Multicast State Table SBE detected. %1$
Explanation
A correctable error was detected in the switch chip. It is automatically corrected by hardware.
[[Inserted string]]%1$: Supplementary code for the error
Solution
If the same message reappears after restarting the switch, note the message contents and contact the sales representative.
260/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Message ID
Severity
S2224
WARNING
S2225
WARNING
S2226
WARNING
S2401
ERROR
Message/Explanation/Solution
Too Many MST SBE Errors. LOG Disabled.
Explanation
A correctable error was repeatedly detected in the switch chip. Logging for this event is disabled.
Solution
Note the message contents and contact the sales representative.
CM Buffer SBE detected. %1$
Explanation
A correctable error was detected in the switch chip. It is automatically corrected by hardware.
[[Inserted string]]%1$: Supplementary code for the error
Solution
If the same message reappears after restarting the switch, note the message contents and contact the sales representative.
Too Many CM Buffer SBE Errors. LOG Disabled.
Explanation
A correctable error was repeatedly detected in the switch chip. Logging for this event is disabled.
Solution
Note the message contents and contact the sales representative.
System Error: %1$
Explanation
A system error of Layer2 basic management module was detected.
[[Inserted string]]%1$: Supplementary code for the error
Solution
Note the message contents and contact the sales representative.
A.2.4 npm (Network Protocol Control: 3000-3299)
Message ID
Severity
S3001
INFO
S3002
INFO
S3003
INFO
S3004
WARNING
S3005
WARNING
Message/Explanation/Solution
Cold Start or Warm Start.
Explanation
The system was turned on.
Link down %1$. (%2$)
Explanation
Port status changed from a link up to a link down state.
[[Inserted string]]%1$: Information on the port whose status changed to a link down.
[[Inserted string]]%2$: Cause of link down.
For details, refer to "Link Status Detail" of the "show interface" command.
Link up %1$.
Explanation
Port status changed to a link up state.
[[Inserted string]]%1$: Information on the port whose status changed to link up.
%1$ detected storm drop.
Explanation
A broadcast storm was detected.
[[Inserted string]]%1$: Information on the port that dropped broadcast frames.
Solution
A loop topology may exist on the network. Review the network configuration.
%1$ detected port security violation.
Explanation
A violating packet was detected by Port Security enabled.
[[Inserted string]]%1$: Information on the port that detected the violating packet.
Solution
Investigate the cause for receiving violating packets.
261/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Message ID
Severity
S3006
WARNING
P3009
INFO
P3010
INFO
P3011
INFO
P3012
INFO
P3013
INFO
P3100
INFO
P3101
INFO
P3102
INFO
P3103
INFO
P3200
INFO
P3201
INFO
Message/Explanation/Solution
%1$ detected loopback alert.
Explanation
A packet loop was detected.
[[Inserted string]]%1$: Information on the port that detected the loop.
Solution
A loop topology may exist on the network. Review the network configuration.
A loopback alert can occur when the destination MAC address of a received frame was registered in the MAC address table with the receiving port registered as a destination. In other words, a loopback alert can occur even if there is no loop in the network.
%1$ has been attached to %2$.
Explanation
The physical port was attached to a link aggregation group.
[[Inserted string]]%1$: Physical port information
[[Inserted string]]%2$: Aggregation group information
%1$ has been detached.
Explanation
The physical port was detached from a link aggregation group.
[[Inserted string]]%1$: Information on physical port detached
%1$ link status details change %2$.
Explanation
The link status of the port changed.
[[Inserted string]]%1$: Port information
[[Inserted string]]%2$: New status of the port
%1$ state is changed to %2$.
Explanation
The STP port state changed.
[[Inserted string]]%1$: Port information
[[Inserted string]]%2$: New state of the STP port
Change ingress-bandwidth %1$ %2$
Explanation
The value set in "ingress-bandwidth" changed.
[[Inserted string]]%1$: Port information
[[Inserted string]]%2$: New value of "ingress-bandwidth"
%1$ has been created.
Explanation
A link aggregation group was added.
[[Inserted string]]%1$: Aggregation group information
%1$ has been deleted.
Explanation
A link aggregation group was deleted.
[[Inserted string]]%1$: Aggregation group information
Initialize LPT setting %1$.
Explanation
The link pass through setting was initialized.
[[Inserted string]]%1$: Port information
Released LPT setting %1$ from %2$.
Explanation
The link pass through setting configured for the port was removed when the port was configured as a member of a link aggregation group.
[[Inserted string]]%1$: Information on the removed port (link status information was sent)
[[Inserted string]]%2$: Information on the monitored port that was removed.
Learned an IGMP multicast router automatically. vlan-%1$ agg-port %2$
Explanation
IGMP snooping learned a multicast router.
[[Inserted string]]%1$: VLAN ID
[[Inserted string]]%2$: Learned aggregation group information
Learned an IGMP multicast router automatically. vlan-%1$ port %2$
Explanation
IGMP snooping learned a multicast router.
262/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Message ID
Severity
P 3202
WARNING
P
WARNING
P
3204
WARNING
P
WARNING
P
WARNING
P
WARNING
P
3208
WARNING
P
WARNING
P
3203
3205
3206
3207
3209
3210
WARNING
P3211
INFO
Message/Explanation/Solution
Received IGMP packet without IP header.
Explanation
Received a frame with a size smaller than that described in the IP header.
Solution
Investigate the cause of faulty frames being sent to the device.
Received IGMP packet with illegal IP version.
Explanation
Received a frame with an illegal IP header version.
Solution
Investigate the cause of faulty frames being sent to the device.
Received IGMP packet with wrong checksum in IP header.
Explanation
Received a frame with an incorrect IP header checksum.
Solution
Investigate the cause of faulty frames being sent to the device.
Received IGMP packet with wrong checksum in IGMP header.
Explanation
Received a frame with an incorrect IGMP header checksum.
Solution
Investigate the cause of faulty frames being sent to the device.
Destination IP-address doesn't match with IGMP group address in IGMP report message.
Explanation
Received a frame containing at destination IP address that does not match the IGMP group address in an IGMP
Report message.
Solution
Investigate the cause of faulty frames being sent to the device.
Received illegal IGMP packet.
Explanation
Received a frame from an undefined IGMP type.
Solution
Investigate the cause of faulty frames being sent to the device.
Bad destination IP-address in IGMP leave message.
Explanation
Received a frame containing an incorrect destination address in an IGMP Leave message.
Solution
Investigate the cause of faulty frames being sent to the device.
Received invalid multicast group address in IGMP packet. group address(%1$) from(%2$)
Explanation
Received a frame containing a non-multicast group address in an IGMP Report message.
[[Inserted string]]%1$: IP group address
[[Inserted string]]%2$: Source IP address
Solution
Investigate the cause of faulty frames being sent to the device.
Cannot register group address more than max-group($1$) per VLAN(%2$) by IGMP snooping.
Explanation
Since the number of group addresses that can be registered using IGMP Snooping reached the upper limit specified in "max-group", no more group addresses can be registered.
[[Inserted string]]%1$: The maximum number of groups that can be registered using the relevant VLAN
[[Inserted string]]%2$: VLAN ID
Solution
Increase the maximum number of groups using the "ip snooping vlan max-group" command.
IGMP snooping has added multicast group address. group(%1$) vlan-%2$ agg-port %3$
Explanation
IGMP snooping added a multicast group MAC address.
[[Inserted string]]%1$: Registered IP group address
[[Inserted string]]%2$: Registered VLAN ID
[[Inserted string]]%3$: Learned aggregation group information
263/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Message ID
Severity
P3212
INFO
P3213
INFO
P3214
INFO
P3215
INFO
P3216
INFO
P3217
INFO
P3218
INFO
P 3219
WARNING
Message/Explanation/Solution
IGMP snooping has added multicast group address. group(%1$) vlan-%2$ port %3$
Explanation
IGMP snooping added a multicast group MAC address.
[[Inserted string]]%1$: Registered IP group address
[[Inserted string]]%2$: Registered VLAN ID
[[Inserted string]]%3$: Registered port number
IGMP snooping has added multicast group address of mrouter. group(%1$) vlan-%2$ agg-port %3$
Explanation
IGMP snooping added a multicast group MAC address to a multicast router port.
[[Inserted string]]%1$: Registered IP group address
[[Inserted string]]%2$: Registered VLAN ID
[[Inserted string]]%3$: Aggregation group number assigned to the registered multicast router
IGMP snooping has added multicast group address of mrouter. group(%1$) vlan-%2$ port %3$
Explanation
IGMP snooping added a multicast group MAC address to a multicast router port.
[[Inserted string]]%1$: Registered IP group address
[[Inserted string]]%2$: Registered VLAN ID
[[Inserted string]]%3$: Port number assigned to the registered multicast router
IGMP snooping has deleted multicast group address. group(%1$) vlan-%2$ agg-port %3$
Explanation
IGMP snooping deleted a multicast group MAC address.
[[Inserted string]]%1$: Deleted IP group address
[[Inserted string]]%2$: Deleted VLAN ID
[[Inserted string]]%3$: Deleted aggregation group number
IGMP snooping has deleted multicast group address. Group(%1$) vlan-%2$ port %3$
Explanation
IGMP snooping deleted a multicast group MAC address.
[[Inserted string]]%1$: Deleted IP group address
[[Inserted string]]%2$: Deleted VLAN ID
[[Inserted string]]%3$: Deleted port number
IGMP snooping has deleted multicast group address of mrouter. group(%1$) vlan-%2$ agg-port %3$
Explanation
IGMP snooping deleted a multicast group MAC address from a multicast router port.
[[Inserted string]]%1$: Deleted IP group address
[[Inserted string]]%2$: Deleted VLAN ID
[[Inserted string]]%3$: Aggregation group number assigned to the deleted multicast router
IGMP snooping has deleted multicast group address of mrouter. group(%1$) vlan-%2$ port %3$
Explanation
IGMP snooping deleted a multicast group MAC address from a multicast router port.
[[Inserted string]]%1$: Deleted IP group address
[[Inserted string]]%2$: Deleted VLAN ID
[[Inserted string]]%3$: Port number assigned to the deleted multicast router
Cannot register group address more than %1$ per system by IGMP snooping. vlan($2$)
Explanation
Since the number of group addresses that can be registered using IGMP Snooping reached the upper limit, no more group addresses can be registered.
[[Inserted string]]%1$: The maximum number of groups that can be registered for the entire switch
[[Inserted string]]%2$: Failed VLAN registration
Solution
Review the registered multicast group addresses using the "show bridge mac-address-table" command to delete unnecessary multicast addresses.
264/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Message ID
Severity
P3300
INFO
P3301
INFO
P3302
INFO
P3303
INFO
P3304
INFO
P3305
INFO
P3306
INFO
P3307
INFO
P3308
INFO
P3309
INFO
P3310
WARNING
Message/Explanation/Solution
cmd-exec[startup]: %1$
Explanation
The command in the startup-config was executed.
[[Inserted string]]%1$: Command string executed in the startup-config. cmd-result[startup]: success
Explanation
The command in the startup-config was successfully completed. cmd-result[startup]: error
Explanation
The command in the startup-config failed. startup-config start.
Explanation
Starts startup-config file processing. startup-config end.
Explanation
Startup-config file processing was successfully completed.
Line has connected. line-ID=%1$
Explanation
The telnet or ssh terminal was connected.
[[Inserted string]]%1$: Terminal ID startup-config end(none).
Explanation
The startup-config file was not found. startup-config end(error).
Explanation
Startup-config file processing failed. cmd-result[startup]: skip
Explanation
Since the attempt to execute the previous command in startup-config resulted in an error, execution of the next command was skipped.
Line has disconnected. line-ID=%1$
Explanation
The telnet or ssh terminal was disconnected.
[[Inserted string]]%1$: Terminal ID
Cannot find host %1$.
Explanation
Failed to find an IP address for the host name specified with the "log send" command.
[[Inserted string]]%1$: Host name specified with the "log send" command
Solution
Review the host name defined.
Check that DNS was configured.
265/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
A.2.6 xgsh (CLI Command History: 4000-4499)
Message ID
Severity
P4001
INFO
P4002
INFO
P4003
INFO
A.2.7
Message/Explanation/Solution
%1$ cmd-exec[%2$]: %3$
Explanation
The command was executed.
[[Inserted string]]%1$: Username
[[Inserted string]]%2$: Terminal ID
[[Inserted string]]%3$: Command string to be executed
%1$ cmd-result[%2$]: success
Explanation
The command was successfully completed.
[[Inserted string]]%1$: Username
[[Inserted string]]%2$: Terminal ID
%1$ cmd-result[%2$]: error
Explanation
The command failed.
[[Inserted string]]%1$: Username
[[Inserted string]]%2$: Terminal ID
rstp (Rapid Spanning Tree Control: 4500-4999)
Message ID
Severity
S4501
WARNING
S4502
WARNING
S4503
WARNING
P4504
WARNING
P4505
WARNING
S4507
WARNING
Message/Explanation/Solution
Root bridge changed.
Explanation
The root bridge changed.
Topology changed.
Explanation
The topology changed.
Received BPDU on PortFast enable port. shutting down %1$.
Explanation
A BPDU was received on a Port Fast-enabled port.
[[Inserted string]]%1$: Name of the port that received the BPDU
Solution
Review the port connection.
Invalid "Forward delay time" relationship 2*(%1$ - 1) >= %2$.
Explanation
The setting of STP Forward Delay is invalid.
[[Inserted string]]%1$: Attempted Forward Delay value change
[[Inserted string]]%2$: The current Max Age value
Solution
Check that the setting of Forward Delay satisfies the following condition.
2 x ((Forward Delay) - 1)
≥ (Max Age)
Invalid "Max age" relationship 2*(%1$ - 1) >= %2$.
Explanation
The setting of STP Max Age is invalid.
[[Inserted string]]%1$: The current Forward Delay value
[[Inserted string]]%2$: Attempted Max Age value change
Solution
Check that the setting of Max Age satisfies the following condition.
2 x ((Forward Delay) - 1)
≥ (Max Age)
Invalid BPDU received on %1$, Bridge becoming root.
Explanation
The reception of an invalid BPDU triggered a topology change that caused the device to become a root switch.
[[Inserted string]]%1$: Name of the port that received the BPDU
Solution
Review the network environment for the port connection.
266/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Message ID
Severity
P4508
WARNING
P4509
WARNING
Message/Explanation/Solution
Invalid "Max age" relationship 2*(%1$ + 1) <= %2$.
Explanation
The setting of STP Max Age is invalid.
[[Inserted string]]%1$: The current Hello Time value
[[Inserted string]]%2$: Attempted Max Age value change
Solution
Check that the setting of Max Age satisfies the following condition.
Max Age
≥ 2 x (Hello Time + 1)
Invalid "Hello time" relationship 2*(%1$ + 1) <= %2$.
Explanation
The setting of Hello Time is invalid.
[[Inserted string]]%1$: Attempted Hello Time value change
[[Inserted string]]%2$: The current Max Age value
Solution
Check that the setting of Hello Time satisfies the following condition.
Max Age
≥ 2 x (Hello Time + 1)
A.2.8 lacp (LACP Control: 5000-5499)
Message ID
Severity
P5001
WARNING
Message/Explanation/Solution
%1$ detects loopback packet.
Explanation
Ports being members of the same link aggregation group are connected.
[[Inserted string]]%1$: Port information
Solution
Review the connection between port being members of the link aggregation.
A.2.9 sys (Maintenance Support Function: 7400-7499)
Message ID
Severity
P7400
INFO
S7410
WARNING
S7411
ERROR
S7490
CRITICAL
S7491
CRITICAL
Message/Explanation/Solution
Dump configuration succeeded.
Explanation
The maintenance support function was successfully initialized.
Could not save a system-dump file.
Explanation
An error occurred while storing the system dump file.
Solution
Note the message contents and contact the sales representative.
Could not execute system-dump.
Explanation
An error occurred while storing the system dump file.
Solution
Note the message contents and contact the sales representative.
A system-dump has been saved. Cause: critical system error occurred.
Explanation
An error occurred while storing the system dump file.
Solution
Obtain maintenance information using the "
tftp put-maintenance " command then take note of the message
content before contacting the sales representative.
A system-dump has been saved. Cause: dump switch was pressed.
Explanation
As the Dump switch was pressed, the system dump was saved.
Solution
Obtain maintenance information using the "
tftp put-maintenance " command then take note of the message
content before contacting the sales representative.
267/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Message ID
Severity
S7492
CRITICAL
S7493
CRITICAL
S7494
CRITICAL
S7495
CRITICAL
Message/Explanation/Solution
A system-dump has been saved. Cause: machine check occurred (memory or bus data error).
Explanation
A machine check error occurred and a system dump saved.
Solution
Obtain maintenance information using the "
tftp put-maintenance " command then take note of the message
content before contacting the sales representative.
A system-dump has been saved. Cause: machine check occurred (bus timeout).
Explanation
A machine check error occurred and a system dump saved.
Solution
Obtain maintenance information using the "
tftp put-maintenance " command then take note of the message
content before contacting the sales representative.
A system-dump has been saved. Cause: machine check occurred (memory or bus data error, bus timeout).
Explanation
A machine check error occurred and a system dump saved.
Solution
Obtain maintenance information using the "
tftp put-maintenance " command then take note of the message
content before contacting the sales representative.
A system-dump has been saved. Cause: machine check occurred.
Explanation
A machine check error occurred and a system dump saved.
Solution
Obtain maintenance information using the "
tftp put-maintenance " command then take note of the message
content before contacting the sales representative.
A.2.10 update (Firmware Update: 7500-7999)
Message ID
Severity
S7500
INFO
S7501
INFO
S7520
WARNING
S7521
WARNING
S7530
CRITICAL
Message/Explanation/Solution
init-firmup: New firmware '%1$' is running.
Explanation
New updated firmware was initialized.
[[Inserted string]]%1$: Firmware version information init-firmup: Firmware '%1$' is running.
Explanation
New firmware was initialized after "boot" command was issued.
[[Inserted string]]%1$: Firmware version information init-firmup: Booting new firmware failed. Old firmware '%1$' is now running.
Explanation
Old firmware was invoked because new updated firmware could not initialize.
[[Inserted string]]%1$: Firmware version information
Solution
Reattempt the update process to boot the new updated firmware.
If the message is repeatedly displayed, contact the sales representative. init-firmup: Firmware update information is initialized for region %1$.
Explanation
The firmware information was initialized.
[[Inserted string]]%1$: Firmware number
Solution
No action is required if this message appears in Step 2 of "
If the message is displayed every time the system is booted, contact the sales representative. init-firmup: Internal error occurred (inconsistency in firmware update information).
Explanation
An error occurred while processing the firmware update information.
[[Inserted string]]%1$: Firmware version information
Solution
Note the message contents and contact the sales representative.
268/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Message ID
Severity
S7531
CRITICAL
S7532
CRITICAL
S7533
CRITICAL
P7600
INFO
P7601
INFO
S7620
ERROR
S7621
CRITICAL
S7622
CRITICAL
S7623
CRITICAL
S7624
ERROR
Message/Explanation/Solution
init-firmup: Internal error occurred (SRAM access error).
Explanation
An error occurred while processing the firmware update information.
Solution
Note the message contents and contact the sales representative. init-firmup: Internal error occurred (FlashROM access error).
Explanation
An error occurred while processing the firmware update information.
Solution
Note the message contents and contact the sales representative. init-firmup: Internal error occurred (SRAM data error: invalid boot parameter).
Explanation
An error occurred while processing the firmware update information.
Solution
Note the message contents and contact the sales representative. firm-update: succeeded (%1$).
Explanation
The firmware update completed successfully.
[[Inserted string]]%1$: Firmware version information firm-update: succeeded (%1$), boot loader updated (%2$).
Explanation
The firmware update completed successfully.
[[Inserted string]]%1$: Firmware version information
[[Inserted string]]%2$: Boot loader version information firm-update: failed (reading file error).
Explanation
An error occurred while updating firmware (failed to read the specified file).
Solution
Check whether the specified file is readable. firm-update: failed (reading FlashROM error: boot loader).
Explanation
An error occurred while updating firmware.
Solution
Reattempt the update process.
If the message is repeatedly displayed, note the message contents and contact the sales representative. firm-update: failed (writing to FlashROM error: boot loader).
Explanation
An error occurred while updating firmware.
Solution
Reattempt the update process.
If the message is repeatedly displayed, note the message contents and contact the sales representative. firm-update: failed (verification error: boot loader).
Explanation
An error occurred while updating firmware.
Solution
Reattempt the update process.
If the message is repeatedly displayed, note the message contents and contact the sales representative. firm-update: failed (writing to FlashROM error: kernel).
Explanation
An error occurred while updating firmware.
Solution
Reattempt the update process.
If the message is repeatedly displayed, note the message contents and contact the sales representative.
269/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Message ID
Severity
S7625
ERROR
S7626
ERROR
S7627
ERROR
S7628
ERROR
S7629
CRITICAL
S7630
CRITICAL
S7631
CRITICAL
S7632
CRITICAL
S7699
CRITICAL
Message/Explanation/Solution
firm-update: failed (verification error: kernel).
Explanation
An error occurred while updating firmware.
Solution
Reattempt the update process.
If the message is repeatedly displayed, note the message contents and contact the sales representative. firm-update: failed (writing to FlashROM error: rootfs).
Explanation
An error occurred while updating firmware.
Solution
Reattempt the update process.
If the message is repeatedly displayed, note the message contents and contact the sales representative. firm-update: failed (verification error: rootfs).
Explanation
An error occurred while updating firmware.
Solution
Reattempt the update process.
If the message is repeatedly displayed, note the message contents and contact the sales representative. firm-update: failed (writing to FlashROM error: EL).
Explanation
An error occurred while updating firmware.
Solution
Reattempt the update process.
If the message is repeatedly displayed, note the message contents and contact the sales representative. firm-update: failed (SRAM access error).
Explanation
An error occurred while updating firmware.
Solution
Reattempt the update process.
If the message is repeatedly displayed, note the message contents and contact the sales representative. firm-update: failed (SRAM data error: invalid firmware update information).
Explanation
An error occurred while updating firmware.
Solution
Reattempting the update process after rebooting the device using the "
If the message is repeatedly displayed, note the message contents and contact the sales representative. firm-update: failed (SRAM data error: invalid boot parameter).
Explanation
An error occurred while updating firmware.
Solution
Reattempting the update process after rebooting the device using the "
If the message is repeatedly displayed, note the message contents and contact the sales representative. firm-update: failed (SRAM data error: no boot command).
Explanation
An error occurred while updating firmware.
Solution
Reattempting the update process after rebooting the device using the "
If the message is repeatedly displayed, note the message contents and contact the sales representative. firm-update: failed (unknown error).
Explanation
An error occurred while updating firmware.
Solution
Note the message contents and contact the sales representative.
270/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
A.2.11 snmp (SNMP Control: 8500-8599)
Message ID
Severity
S8500
INFO
S8501
INFO
S8502
INFO
P8510
WARNING
Message/Explanation/Solution
SNMP authentication failure.
Explanation
The device denied an SNMP request from a SNMP manager.
Solution
Review the SNMP permission from the SNMP manager using the "snmp access" command.
RMON alarm
by rising-threshold.
index:%1$ OID:%2$ sample:%3$ value:%4$ rising-threshold:%5$
Explanation
The current sampled value was greater than the upper threshold defined by the "rmon alarm" command. A
SNMP trap for the corresponding RMON event was generated.
[[Inserted string]]%1$: RMON alarm index
[[Inserted string]]%2$: OID of MIB object to be monitored
[[Inserted string]]%3$: Method of determining threshold
1: An absolute value is used when determining threshold (absolute)
2: The difference between the previous and current values is used when determining threshold (delta)
[[Inserted string]]%4$: Value of MIB object to be monitored
[[Inserted string]]%5$: Upper threshold of MIB object to be monitored
RMON alarm by falling-threshold.
index:%1$ OID:%2$ sample:%3$ value:%4$ falling-threshold:%5$
Explanation
The current sampled value was less than the lower threshold defined by the "rmon alarm" command, and a
SNMP trap for the corresponding RMON event was generated.
[[Inserted string]]%1$: RMON alarm index
[[Inserted string]]%2$: OID of MIB object to be monitored
[[Inserted string]]%3$: Method of determining threshold
1: An absolute value is used when determining threshold (absolute)
2: The difference between the previous and current values is used when determining threshold (delta)
[[Inserted string]]%4$: Value of MIB object to be monitored
[[Inserted string]]%5$: Lower threshold of MIB object to be monitored
Cannot find host %1$.
Explanation
Failed to find an IP address for the host name specified with the "snmp-server trap" command.
[[Inserted string]]%1$: Host name specified with the "snmp-server trap" command
Solution
Review the host name defined. Check that DNS was configured.
271/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
A.2.12 ntp (NTP Control: 8600-8699)
Message ID
Severity
P8601
WARNING
P8602
INFO
P8603
WARNING
P8691
ERROR
Message/Explanation/Solution
No server suitable for synchronization found.
Explanation
No NTP server is found.
Solution
Check the NTP server host name defined by the "ntp-server" command as well as the NTP server operating status.
Time server %1$ offset %2$ sec.
Explanation
Time synchronization using a NTP server was performed to correct the time.
[[Inserted string]]%1$: Host name or IP address of the NTP server that corrected the time
[[Inserted string]]%2$: Corrected time difference in seconds
Cannot find host %1$.
Explanation
Failed to find an IP address from the host name specified with the "ntp-server host" command.
[[Inserted string]]%1$: Host name specified with the "ntp-server host" command
Solution
Review the host name defined.
Check that DNS was configured.
System Error: %1$
Explanation
A system error occurred while NTP time synchronization was in progress.
[[Inserted string]]%1$: Additional information on the error
Solution
Note the message contents and contact the sales representative.
272/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
A.3 Message Format for Forwarding syslog
The logs output from the device can be forwarded to a syslog server. The device forwards logs in a message format that conforms to the RFC3164 The BSD Syslog Protocol.
The format the device uses to forward a syslog message to the syslog server is shown below.
Format of syslog message in XG2000 series
Description Format of syslog message in
RFC3164
Priority Priority string PRI part Priority
Time HEADER part TimeStamp
Host name
Device type
Function type
Severity
Message ID
The time the message was generated
(MM:DD:HH:MM:SS)
Host name of the device
XG
Abbreviated name for the control that output the message.
Severity of the message
The code that uniquely identifies the message
MSG part
HostName
Tag
Content
The device appends the Priority value at the beginning of the log message then inserts the Device type between the Host name and the Function type before forwarding the message to the specified syslog server.
The Priority value is used to identify the severity and facility of a log message.
It is added according to the following rules.
Priority must have three, four, or five characters. It starts with an angle bracket "<", followed by a number, followed by an angle bracket ">". Example: <14>
The Priority value is calculated from the Facility code (Facility) and the Severity code (Severity). The Priority value consists of one, two, or three decimal integers.
The Priority value is calculated by first multiplying the Facility code by 8 and then adding the numerical value of the
Severity code.
The Facility code defined in the device is:
Facility code Type of Facility
1 random user-level messages
The Severity codes defined in the device are:
Severity code Description of Severity
2
3
4
6
Critical : critical conditions
Error : error conditions
Warning : warning conditions
Informational : informational messages
273/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Appendix B SNMP Traps
This appendix lists the SNMP traps supported by the device.
Standard SNMP Traps
Trap name RFC Trap OID
Enterprise-specific traps that are specific to the device report the following information.
(OID becomes 1.3.6.1.4.1.211.1.127.61.108.* in case of XG2000C, and 1.3.6.1.4.1.211.1.127.61.109.* in case of XG2000CR)
Field OID Object name
Trap OID
Variable list
1.3.6.1.4.1.211.1.127.61.107.2.0."message number" xg2000***
1.3.6.1.4.1.211.1.127.61.107.2.10.1 xg2000TrapLevel
1.3.6.1.4.1.211.1.127.61.107.2.10.2 xg2000TrapMessage
"xg2000***" differs from one event to another.
"xg2000TrapLevel" indicates the severity of an event. The severities are defined as:
Severity Value
Critical 0
Error 1
Warning 2
Info 3
"xg2000TrapMessage" indicates a message that relates to an event.
The messages are the same as those for the event logs.
274/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Appendix C List of MIBs
This appendix lists the MIBs supported by the device.
For a definition of each object, refer to RFC.
MIB-II system group (RFC3418) iso(1).org(3).dod(6).internet(1).mgmt(2).mib-2(1).system(1)
Item number
Object identifier SYNTAX
DisplayString 1 sysDescr
{system 1}
2 sysObjectID
{system 2}
3 sysUpTime
{system 3}
4 sysContact
{system 4}
OBJECT IDENTIFIER
TimeTicks
DisplayString
5 sysName
{system 5}
6 sysLocation
{system 6}
7 sysServices
{system 7}
DisplayString
DisplayString
INTEGER
IF MIB (RFC2863) iso(1).org(3).dod(6).internet(1).mgmt(2).mib-2(1).interface(2)
Item Object identifier SYNTAX number
1 ifNumber
{interface 1}
INTEGER32
NOT-ACCESSIBLE 2 ifTable
{interface 2}
3 ifEntry
{ifTable 1}
4 ifIndex
{ifEntry 1}
5 ifDescr
{ifEntry 2}
6 ifType
{ifEntry 3}
NOT-ACCESSIBLE
InterfaceIndex
DisplayString
IANAifType
INTEGER32 7 ifMtu
{ifEntry 4}
8 ifSpeed
{ifEntry 5}
9 ifPhysAddress
{ifEntry 6}
10 ifAdminStatus
{ifEntry 7}
11 ifOperStatus
{ifEntry 8}
12 ifLastChange
{ifEntry 9}
Gauge32
PhysAddress
INTEGER
INTEGER
TimeTicks
13 ifInOctets
{ifEntry 10}
14 ifInUcastPkts
{ifEntry 11}
15 ifInNUcastPkts
{ifEntry 12}
16 ifInDiscards
{ifEntry 13}
17 ifInErrors
{ifEntry 14}
18 ifInUnknownProtos
{ifEntry 15}
19 ifOutOctets
{ifEntry 16}
20 ifOutUcastPkts
{ifEntry 17}
21 ifOutNUcastPkts
{ifEntry 18}
22 ifOutDiscards
{ifEntry 19}
23 ifOutErrors
{ifEntry 20}
24 ifOutQLen
{ifEntry 21}
25 ifSpecific
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Gauge32
275/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Item number
Object identifier SYNTAX
{ifEntry 22}
Ether-like MIB (RFC2665) iso(1).org(3).dod(6).internet(1).mgmt(2).mib-2(1).transmission(10).dot3(7)
Item number
Object identifier
1 dot3StatsTable
{dot3 2}
2 dot3StatsEntry
{dot3StatsTable 1}
SYNTAX
NOT-ACCESSIBLE
NOT-ACCESSIBLE
3 dot3StatsIndex
{dot3StatsEntry 1}
4 dot3StatsAlignmentErrors
{dot3StatsEntry 2}
5 dot3StatsFCSErrors
{dot3StatsEntry 3}
6 dot3StatsSingleCollisionFrames
{dot3StatsEntry 4}
7 dot3StatsMultipleCollisionFrames
{dot3StatsEntry 5}
InterfaceIndex
Counter32
Counter32
Counter32
Counter32
Counter32 8 dot3StatsSQETestErrors
{dot3StatsEntry 6}
9 dot3StatsDeferredTransmissions
{dot3StatsEntry 7}
10 dot3StatsLateCollisions
{dot3StatsEntry 8}
11 dot3StatsExcessiveCollisions
{dot3StatsEntry 9}
12 dot3StatsInternalMacTransmitErrors
{dot3StatsEntry 10}
13 dot3StatsCarrierSenseErrors
{dot3StatsEntry 11}
14 dot3StatsFrameTooLongs
{dot3StatsEntry 13}
15 dot3StatsInternalMacReceiveErrors
{dot3StatsEntry 16}
16 dot3StatsEtherChipSet
{dot3StatsEntry 17}
17 dot3StatsSymbolErrors
{dot3StatsEntry 18}
18 dot3StatsDuplexStatus
{dot3StatsEntry 19}
19 dot3ControlTable
{dot3 9}
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
OBJECT IDENTIFIER
Counter32
INTEGER
NOT-ACCESSIBLE
20 dot3ControlEntry
{dot3ControlTable 1}
21 dot3ControlFunctionsSupported
{dot3ControlEntry 1}
22 dot3ControlInUnknownOpcodes
{dot3ControlEntry 2}
23 dot3PauseTable
{dot3 10}
24 dot3PauseEntry
{dot3PauseTable 1}
25 dot3PauseAdminMode
{dot3PauseEntry 1}
26 dot3PauseOperMode
{dot3PauseEntry 2}
27 dot3InPauseFrames
{dot3PauseEntry 3}
28 dot3OutPauseFrames
{dot3PauseEntry 4}
NOT-ACCESSIBLE
BITS
Counter32
NOT-ACCESSIBLE
NOT-ACCESSIBLE
INTEGER
INTEGER
Counter32
Counter32
MIB-II snmp group (RFC1213) iso(1).org(3).dod(6).internet(1).mgmt(2).mib-2(1).snmp(11)
Item Object identifier number
Counter32 1 snmpInPkts
{snmp 1}
2 snmpOutPkts
{snmp 2}
Counter32
Counter32 3 snmpInBadVersions
{snmp 3}
4 snmpInBadCommunityNames
{snmp 4}
5 snmpInBadCommunityUses
Counter32
SYNTAX
Counter32
276/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Item number
Object identifier
{snmp 5}
6 snmpInASNParseErrs
{snmp 6}
7 snmpInTooBigs
{snmp 8}
8 snmpInNoSuchNames
{snmp 9}
9 snmpInBadValues
{snmp 10}
10 snmpInReadOnlys
{snmp 11}
11 snmpInGenErrs
{snmp 12}
12 snmpInTotalReqVars
{snmp 13}
13 snmpInTotalSetVars
{snmp 14}
14 snmpInGetRequests
{snmp 15}
15 snmpInGetNexts
{snmp 16}
16 snmpInSetRequests
{snmp 17}
17 snmpInGetSolutions
{snmp 18}
18 snmpInTraps
{snmp 19}
19 snmpOutTooBigs
{snmp 20}
20 snmpOutNoSuchNames
{snmp 21}
21 snmpOutBadValues
{snmp 22}
22 snmpOutGenErrs
{snmp 24}
23 snmpOutGetRequests
{snmp 25}
24 snmpOutGetNexts
{snmp 26}
25 snmpOutSetRequests
{snmp 27}
26 snmpOutGetSolutions
{snmp 28}
27 snmpOutTraps
{snmp 29}
28 snmpEnableAuthenTraps
{snmp 30}
29 snmpSilentDrops
{snmp 31}
30 snmpProxyDrops
{snmp 32}
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
INTEGER
Counter32
Counter32
SYNTAX
RMON MIB(statistics group) (RFC2819) iso(1).org(3).dod(6).internet(1).mgmt(2).mib-2(1).rmon(16).statistics(1)
Item number
Object identifier
1 etherStatsTable
{statistics 1}
2 etherStatsEntry
{etherStatsTable 1}
3 etherStatsIndex
{etherStatsEntry 1}
4 etherStatsDataSource
{etherStatsEntry 2}
5 etherStatsDropEvents
{etherStatsEntry 3}
NOT-ACCESSIBLE
NOT-ACCESSIBLE
Integer32
Counter32
SYNTAX
OBJECT IDENTIFIER
6 etherStatsOctets
{etherStatsEntry 4}
7 etherStatsPkts
{etherStatsEntry 5}
8 etherStatsBroadcastPkts
{etherStatsEntry 6}
9 etherStatsMulticastPkts
{etherStatsEntry 7}
10 etherStatsCRCAlignErrors
{etherStatsEntry 8}
Counter32
Counter32
Counter32
Counter32
Counter32
277/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Item number
Object identifier
11 etherStatsUndersizePkts
{etherStatsEntry 9}
12 etherStatsOversizePkts
{etherStatsEntry 10}
13 etherStatsFragments
{etherStatsEntry 11}
14 etherStatsJabbers
{etherStatsEntry 12}
15 etherStatsCollisions
{etherStatsEntry 13}
16 etherStatsPkts64Octets
{etherStatsEntry 14}
17 etherStatsPkts65to127Octets
{etherStatsEntry 15}
18 etherStatsPkts128to255Octets
{etherStatsEntry 16}
19 etherStatsPkts256to511Octets
{etherStatsEntry 17}
20 etherStatsPkts512to1023Octets
{etherStatsEntry 18}
21 etherStatsPkts1024to1518Octets
{etherStatsEntry 19}
22 etherStatsOwner
{etherStatsEntry 20}
23 etherStatsStatus
{etherStatsEntry 21}
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
OwnerString
EntryStatus
SYNTAX
RMON MIB (history group) (RFC2819) iso(1).org(3).dod(6).internet(1).mgmt(2).mib-2(1).rmon(16).history(2)
Item number
Object identifier
1 historyControlTable
{history 1}
2 historyControlEntry
{historyControlTable 1}
SYNTAX
NOT-ACCESSIBLE
NOT-ACCESSIBLE
3 historyControlIndex
{historyControlEntry 1}
4 historyControlDataSource
{historyControlEntry 2}
5 historyControlBucketsRequested
{historyControlEntry 3}
6 historyControlBucketsGranted
{historyControlEntry 4}
7 historyControlInterval
{historyControlEntry 5}
Integer32
OBJECT IDENTIFIER
Integer32
Integer32
Integer32
OwnerString 8 historyControlOwner
{historyControlEntry 6}
9 historyControlStatus
{historyControlEntry 7}
10 etherHistoryTable
{history 2}
11 etherHistoryEntry
{etherHistoryTable 1}
12 etherHistoryIndex
{etherHistoryEntry 1}
13 etherHistorySampleIndex
{etherHistoryEntry 2}
14 etherHistoryIntervalStart
{etherHistoryEntry 3}
15 etherHistoryDropEvents
{etherHistoryEntry 4}
16 etherHistoryOctets
{etherHistoryEntry 5}
17 etherHistoryPkts
{etherHistoryEntry 6}
18 etherHistoryBroadcastPkts
{etherHistoryEntry 7}
19 etherHistoryMulticastPkts
{etherHistoryEntry 8}
20 etherHistoryCRCAlignErrors
{etherHistoryEntry 9}
21 etherHistoryUndersizePkts
{etherHistoryEntry 10}
22 etherHistoryOversizePts
{etherHistoryEntry 11}
23 etherHistoryFragments
EntryStatus
NOT-ACCESSIBLE
NOT-ACCESSIBLE
Integer32
Integer32
TimeTicks
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
278/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Item number
Object identifier
{etherHistoryEntry 12}
24 etherHistoryJabbers
{etherHistoryEntry 13}
25 etherHistoryCollisions
{etherHistoryEntry 14}
26 etherHistoryUtilization
{etherHistoryEntry 15}
Counter32
Counter32
Integer32
SYNTAX
RMON MIB (alarm group) (RFC2819) iso(1).org(3).dod(6).internet(1).mgmt(2).mib-2(1).rmon(16).alarm(3)
Item number
Object identifier SYNTAX
NOT-ACCESSIBLE 1 alarmTable
{alarm 1}
2 alarmEntry
{alarmTable 1}
3 alarmIndex
{alarmEntry 1}
4 alarmInterval
{alarmEntry 2}
NOT-ACCESSIBLE
Integer32
Integer32
OBJECT IDENTIFIER 5 alarmVariable
{alarmEntry 3}
6 alarmSampleType
{alarmEntry 4}
7 alarmValue
{alarmEntry 5}
8 alarmStartupAlarm
{alarmEntry 6}
9 alarmRisingThreshold
{alarmEntry 7}
10 alarmFallingThreshold
{alarmEntry 8}
11 alarmRisingEventIndex
{alarmEntry 9}
12 alarmFallingEventIndex
{alarmEntry 10}
13 alarmOwner
{alarmEntry 11}
14 alarmStatus
{alarmEntry 12}
INTEGER
Integer32
INTEGER
Integer32
Integer32
Integer32
Integer32
OwnerString
EntryStatus
RMON MIB (event group) (RFC2819) iso(1).org(3).dod(6).internet(1).mgmt(2).mib-2(1).rmon(16).event(9)
Item number
Object identifier
1 eventTable
{event 1}
SYNTAX
NOT-ACCESSIBLE
NOT-ACCESSIBLE 2 eventEntry
{eventTable 1}
3 eventIndex
{eventEntry 1}
4 eventDescription
{eventEntry 2}
5 eventType
{eventEntry 3}
6 eventCommunity
{eventEntry 4}
7 evenvLastTimeSent
{eventEntry 5}
Integer32
DisplayString
INTEGER
OCTET STRING
TimeTicks
OwnerString 8 eventOwner
{eventEntry 6}
9 eventStatus
{eventEntry 7}
10 logTable
{event 2}
11 logEntry
{logTable 1}
12 logEventIndex
{logEntry 1}
13 logIndex
{logEntry 2}
14 logTime
{logEntry 3}
15 logDescription
{logEntry 4}
EntryStatus
NOT-ACCESSIBLE
NOT-ACCESSIBLE
Integer32
Integer32
TimeTicks
DisplaySting
279/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Bridge MIB (RFC1493) iso(1).org(3).dod(6).internet(1).mgmt(2).mib-2(1).dot1dBridge (17)
Item number
Object identifier
1 dot1dBase
{dot1dBridge 1}
2 dot1dBaseBridgeAddress
{dot1dBase 1}
3 dot1dBaseNumPorts
{dot1dBase 2}
MacAddress
INTEGER
SYNTAX
NOT-ACCESSIBLE
INTEGER 4 dot1dBaseType
{dot1dBase 3}
5 dot1dBasePortTable
{dot1dBase 4}
6 dot1dBasePortEntry
{dot1dBasaPortTable 1}
7 dot1dBasePort
{dot1dBasePortEntry 1}
8 dot1dBasePortIfIndex
{dot1dBasePortEntry 2}
9 dot1dBasePortCircuit
{dot1dBasePortEntry 3}
10 dot1dBasePortDelayExceededDiscards
{dot1dBasePortEntry 4}
11 dot1dBasePortMtuExceededDiscards
{dot1dBasePortEntry 5}
NOT-ACCESSIBLE
NOT-ACCESSIBLE
INTEGER
INTEGER
OBJECT IDENTIFIER
Counter32
Counter32
NOT-ACCESSIBLE 12 dot1dStp
{dot1dBridge 2}
13 dot1dStpProtocolSpecification
{dot1dStp 1}
14 dot1dStpPriority
{dot1dStp 2}
15 dot1dStpTimeSinceTopologyChange
{dot1dStp 3}
16 dot1dStpTopChanges
{dot1dStp 4}
17 dot1dStpDesignatedRoot
{dot1dStp 5}
18 dot1dStpRootCost
{dot1dStp 6}
19 dot1dStpRootPort
{dot1dStp 7}
20 dot1dStpMaxAge
{dot1dStp 8}
21 dot1dStpHelloTime
{dot1dStp 9}
22 dot1dStpHoldTime
{dot1dStp 10}
23 dot1dStpForwardDelay
{dot1dStp 11}
INTEGER
INTEGER
TimeTicks
Counter
BridgeID
INTEGER
INTEGER
Timeout
Timeout
INTEGER
Timeout
24 dot1dStpBridgeMaxAge
{dot1dStp 12}
25 dot1dStpBridgeHelloTime
{dot1dStp 13}
26 dot1dStpBridgeForwardDelay
{dot1dStp 14}
27 dot1dStpPortTable
{dot1dStp 15}
28 dot1dStpPortEntry
{dot1dStpPortTable 1}
29 dot1dStpPort
{dot1dStpPortEntry 1}
30 dot1dStpPortPriority
{dot1dStpPortEntry 2}
31 dot1dStpPortState
{dot1dStpPortEntry 3}
32 dot1dStpPortEnable
{dot1dStpPortEntry 4}
33 dot1dStpPortPathCost
{dot1dStpPortEntry 5}
34 dot1dStpPortDesignatedRoot
{dot1dStpPortEntry 6}
35 dot1dStpPortDesignatedCost
{dot1dStpPortEntry 7}
36 dot1dStpPortDesignatedBridge
{dot1dStpPortEntry 8}
37 dot1dStpPortDesignatedPort
{dot1dStpPortEntry 9}
Timeout
Timeout
Timeout
NOT-ACCESSIBLE
NOT-ACCESSIBLE
INTEGER
INTEGER
INTEGER
INTEGER
INTEGER
BridgeId
INTEGER
BridgeId
OCTET STRING
280/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Item number
Object identifier
38 dot1dStpPortForwardTransitions
{dot1dStpPortEntry 10}
39 dot1dTp
{dot1dBridge 4}
40 dot1dTpLearnedEntryDiscards
{dot1dTp 1}
41 dot1dTpAgingTime
{dot1dTp 2}
42 dot1dTpPortTable
{dot1dTp 4}
43 dot1dTpPortEntry
{dot1dTpPortTable 1}
44 dot1dTpPort
{dot1dTpPortEntry 1}
45 dot1dTpPortMaxInfo
{dot1dTpPortEntry 2}
46 dot1dTpPortInFrames
{dot1dTpPortEntry 3}
47 dot1dTpPortOutFrames
{dot1dTpPortEntry 4}
48 dot1dTpPortInDiscards
{dot1dTpPortEntry 5}
49 dot1dTpHCPortTable
{dot1dTp 5}
50 dot1dTpHCPortEntry
{dot1dTpHCPortTable 1}
51 dot1dTpHCPortInFrames
{dot1dTpHCPortEntry 1}
52 dot1dTpHCPortOutFrames
{dot1dTpHCPortEntry 2}
53 dot1dTpHCPortInDiscards
{dot1dTpHCPortEntry 3}
54 dot1dTpPortOverflowTable
{dot1dTp 6}
55 dot1dTpPortOverflowEntry
{dot1dTpPortOverflowTable 1}
56 dot1dTpPortInOverflowFrames
{dot1dTpPortOverflowEntry 1}
57 dot1dTpPortOutOverflowFrames
{dot1dTpPortOverflowEntry 2}
58 dot1dTpPortInOverflowDiscards
{dot1dTpPortOverflowEntry 3}
SYNTAX
Counter
NOT-ACCESSIBLE
Counter
INTEGER
NOT-ACCESSIBLE
NOT-ACCESSIBLE
INTEGER
INTEGER
Counter
Counter
Counter
NOT-ACCESSIBLE
NOT-ACCESSIBLE
Counter64
Counter64
Counter64
NOT-ACCESSIBLE
NOT-ACCESSIBLE
Counter32
Counter32
Counter32
P-Bridge MIB (RFC2674) iso(1).org(3).dod(6).internet(1).mgmt(2).mib-2(1).dot1dBridge(17).pBridgeMIB(6)
Item number
Object identifier
1 pBridgeMIBObjects
{pBridgeMIB 1}
2 dot1dExtBase
{pBridgeMIBObjects 1}
SYNTAX
NOT-ACCESSIBLE
NOT-ACCESSIBLE
BITS 3 dot1dDeviceCapabilities
{dot1dExtBase 1}
4 dot1dTrafficClassesEnabled
{dot1dExtBase 2}
5 dot1dPortCapabilitiesTable
{dot1dExtBase 4}
6 dot1dPortCapabilitiesEntry
{dot1dPortCapabilitiesTable 1}
7 dot1dPortCapabilities
{dot1dPortCapabilitiesEntry 1}
8 dot1dPriority
{pBridgeMIBObjects 2}
TruthValue
NOT-ACCESSIBLE
NOT-ACCESSIBLE
BITS
NOT-ACCESSIBLE
NOT-ACCESSIBLE 9 dot1dPortPriorityTable
{dot1dPriority 1}
10 dot1dPortPriorityEntry
{dot1dPortPriorityTable 1}
11 dot1dPortDefaultUserPriority
{dot1dPortPriorityEntry 1}
12 dot1dPortNumTrafficClasses
{dot1dPortPriorityEntry 2}
13 dot1dTrafficClassTable
{dot1dPriority 3}
14 dot1dTrafficClassEntry
{dot1dTrafficClassTable 1}
15 dot1dTrafficClassPriority
NOT-ACCESSIBLE
INTEGER
INTEGER
NOT-ACCESSIBLE
NOT-ACCESSIBLE
INTEGER
281/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
Item number
Object identifier
{dot1dTrafficClassEntry 1}
16 dot1dTrafficClass
{dot1dTrafficClassEntry 2}
INTEGER
SYNTAX
Q-Bridge MIB (RFC2674) iso(1).org(3).dod(6).internet(1).mgmt(2).mib-2(1).dot1dBridge(17).QBridgeMIB(7)
Item Object identifier SYNTAX number
1 qBridgeMIBObjects
{qBridgeMIB 1}
NOT-ACCESSIBLE
NOT-ACCESSIBLE 2 dot1qBase
{qBridgeMIBObjects 1}
3 dot1qVlanVersionNumber
{dot1qBase 1}
4 dot1qMaxVlanId
{dot1qBase 2}
5 dot1qMaxSupportedVlans
{dot1qBase 3}
6 dot1qNumVlans
{dot1qBase 4}
INTEGER
VlanId
Unsigned32
Unsigned32
EnabledStatus 7 dot1qGvrpStatus
{dot1qBase 5}
8 dot1qVlan
{qBridgeMIBObjects 4}
9 dot1qVlanNumDeletes
{dot1qVlan 1}
10 dot1qVlanCurrentTable
{dot1qVlan 2}
11 dot1qVlanCurrentEntry
{dot1qVlanCurrentTable 1}
12 dot1qVlanTimeMark
{dot1qVlanCurrentEntry 1}
NOT-ACCESSIBLE
Counter32
NOT-ACCESSIBLE
NOT-ACCESSIBLE
TimeFilter
VlanIndex 13 dot1qVlanIndex
{dot1qVlanCurrentEntry 2}
14 dot1qVlanFdbId
{dot1qVlanCurrentEntry 3}
15 dot1qVlanCurrentEgressPorts
{dot1qVlanCurrentEntry 4}
16 dot1qVlanCurrentUntaggedPorts
{dot1qVlanCurrentEntry 5}
17 dot1qVlanStatus
{dot1qVlanCurrentEntry 6}
18 dot1qVlanCreationTime
{dot1qVlanCurrentEntry 7}
19 dot1qVlanStaticTable
{dot1qVlan 3}
20 dot1qVlanStaticEntry
{dot1qVlanStaticTable 1}
21 dot1qVlanStaticName
{dot1qVlanStaticEntry 1}
22 dot1qVlanStaticEgressPorts
{dot1qVlanStaticEntry 2}
23 dot1qVlanForbiddenEgressPorts
{dot1qVlanStaticEntry 3}
24 dot1qVlanStaticUntaggedPorts
{dot1qVlanStaticEntry 4}
25 dot1qVlanStaticRowStatus
{dot1qVlanStaticEntry 5}
26 dot1qNextFreeLocalVlanIndex
{dot1qVlan 4}
27 dot1qPortVlanTable
{dot1qVlan 5}
28 dot1qPortVlanEntry
{dot1qPortVlanTable 1}
29 dot1qPvid
{dot1qPortVlanEntry 1}
30 dot1qPortAcceptableFrameTypes
{dot1qPortVlanEntry 2}
31 dot1qPortIngressFiltering
{dot1qPortVlanEntry 3}
32 dot1qPortGvrpStatus
{dot1qPortVlanEntry 4}
33 dot1qPortGvrpFailedRegistrations
{dot1qPortVlanEntry 5}
34 dot1qPortGvrpLastPduOrigin
{dot1qPortVlanEntry 6}
Unsigned32
PortList
PortList
INTEGER
TimeTicks
NOT-ACCESSIBLE
NOT-ACCESSIBLE
SnmpAdminString
PortList
PortList
PortList
RowStatus
INTEGER
NOT-ACCESSIBLE
NOT-ACCESSIBLE
VlanIndex
INTEGER
TruthValue
EnabledStatus
Counter32
MacAddress
282/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
IF MIB (RFC2863) iso(1).org(3).dod(6).internet(1).mgmt(2).mib-2(1). ifMIB (31)
Item Object identifier SYNTAX number
1 ifMIBObjects
{ifMIB 1}
NOT-ACCESSIBLE
NOT-ACCESSIBLE 2 ifXTable
{ifMIBObjects 1}
3 ifXEntry
{ifXTable 1}
4 ifName
{ifXEntry 1}
5 ifInMulticastPkts
{ifXEntry 2}
6 ifInBroadcastPkts
{ifXEntry 3}
NOT-ACCESSIBLE
DisplayString
Counter32
Counter32
Counter32 7 ifOutMulticastPkts
{ifXEntry 4}
8 ifOutBroadcastPkts
{ifXEntry 5}
9 ifHCInOctets
{ifXEntry 6}
10 ifHCInUcastPkt
{ifXEntry 7}
11 ifHCInMulticastPkts
{ifXEntry 8}
12 ifHCInBroadcastPkts
{ifXEntry 9}
Counter32
Counter64
Counter64
Counter64
Counter64
Counter64 13 ifHCOutOctets
{ifXEntry 10}
14 ifHCOutUcastPkts
{ifXEntry 11}
15 ifHCOutMulticastPkts
{ifXEntry 12}
16 ifHCOutBroadcastPkts
{ifXEntry 13}
17 ifLinkUpDownTrapEnable
{ifXEntry 14}
18 ifHighSpeed
{ifXEntry 15}
19 ifPromiscuousMode
{ifXEntry 16}
20 ifConnectorPresent
{ifXEntry 17}
21 ifAlias
{ifXEntry 18}
22 ifCounterDiscontinuityTime
{ifXEntry 19}
Counter64
Counter64
Counter64
INTEGER
Gauge32
TruthValue
TruthValue
DisplayString
TimeTicks
283/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
FUJITSU-XG2000-MIB iso(1).org(3).dod(6)internet(1).private(4).enterprises(1).fujitsu(211).
Item number
Product(1).nonos(127).xg-switch(61).xg2000(107)
(*.xg2000(107) becomes *.xg2000(108) in case of XG2000C, and *.xg2000(109) in case of XG2000CR)
Object identifier
1 xg2000Monitor
{xg2000 1}
2 xg2000InternalTemperature
{xg2000Monitor 1}
3 xg2000LoadAverage
{xg2000Monitor 3}
SYNTAX
NOT-ACCESSIBLE
Integer32
Integer32
Description
Object identifier of monitor information specific to the device.
Indicates the temperature inside the chassis (in degree Celsius).
Indicates the CPU usage (in %).
4 xg2000Event
{xg2000 2}
5 xg2000Traps
{xg2000Event 0}
6 xg2000***
{xg2000Traps X}
7 xg2000TrapInfo
{xg2000Event 10}
8 xg2000TrapLevel
{xg2000TrapInfo 1}
9 xg2000TrapMessage
{xg2000TrapInfo 2}
NOT-ACCESSIBLE
NOT-ACCESSIBLE
NOT-ACCESSIBLE
NOT-ACCESSIBLE
Integer32
DisplayString
Object identifier of trap information specific to the device.
Object identifier of trap information specific to the device.
Object identifier of message information trap.
"xg2000***" differs from one event to another. "X" indicates the message number to be reported.
Object identifier of additional information on message information trap.
Specifies the severity of message. critical(0) error(1) warning(2) info(3)
Displays message text when sending a trap.
284/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
A
Aborting Command ...................................................................... 18
About Command Reference......................................................... 56 account......................................................................................... 75
ï¼¢
Index
Extraction of Maintenance Information....................................... 247
F
Features ....................................................................................... 10
Filtering show Command Output.................................................. 19
Flow Control ................................................................................. 28 flowcontrol .................................................................................. 128
Format of Log Message ............................................................. 242
Frame Distribution Methods in Link Aggregation ......................... 34 banner .......................................................................................... 85 baud-rate ...................................................................................... 66 boot-system................................................................................ 236 bridge aging-time........................................................................ 108 bridge diffserv-tos....................................................................... 161 bridge forward-mode .................................................................. 102 bridge jumbo-frame .................................................................... 103 bridge learn-mode ...................................................................... 104 bridge mac-address-table........................................................... 105 bridge mac-address-table filter................................................... 107
G generate ssh-host-key.................................................................. 68
H help............................................................................................... 74 hostname ..................................................................................... 62
How to Enter Commands ............................................................. 16
ï¼£
I clear bridge mac-address-table.................................................... 99 clear log...................................................................................... 228 clear maintenance ...................................................................... 233 clear statistics..............................................................................211 clear violation ............................................................................. 125
Command Abbreviation................................................................ 17
Command Completion ................................................................. 17
Command History......................................................................... 18
Command Modes and Mode Switching ....................................... 13
Command Reference ................................................................... 55
Command System........................................................................ 56
Command-Line Error Messages .................................................. 17
Configuration File Operation Commands..................................... 87
Configuration of Command Reference......................................... 57
Configure Management LAN Interface......................................... 23 configure terminal......................................................................... 72
Configuring IGMP Snooping......................................................... 52
Configuring Link Aggregation ....................................................... 33
Configuring Spanning Tree........................................................... 40
Context-Sensitive Help................................................................. 16 copy startup-config ................................................................ 92 copy running-config startup-config ............................................... 87
Cut-through switching mode ........................................................ 27
D
IEEE802.1Q ................................................................................. 42
IGMP Querier ............................................................................... 51
IGMP Snooping ............................................................................ 47
IGMP Snooping Setup Commands ............................................ 166
Ingress Rate Control .................................................................... 29 ingress-bandwidth ...................................................................... 133 ingress-filter no-vlan-member-frame .......................................... 156 ingress-filter tagged-frame ......................................................... 157 ingress-filter untagged-frame ..................................................... 157 interface port .............................................................................. 126 interface vlan.............................................................................. 152 ip snooping................................................................................. 177 ip snooping fast-leave ................................................................ 181 ip snooping group-member-interval ........................................... 180 ip snooping last-member-interval ............................................... 182 ip snooping max-group............................................................... 178 ip snooping mrouter ................................................................... 179 ip snooping protocol ................................................................... 168 ip snooping querier..................................................................... 184 ip snooping send-query-count.................................................... 183 ip snooping vlan ......................................................................... 169 ip snooping vlan fast-leave......................................................... 173 ip snooping vlan group-member-interval.................................... 172 ip snooping vlan last-member-query-interval ............................. 174 ip snooping vlan max-group ....................................................... 170 ip snooping vlan mrouter............................................................ 171 ip snooping vlan querier ............................................................. 176 ip snooping vlan send-query-count ............................................ 175
IVL ................................................................................................ 27 date .............................................................................................. 79 date set......................................................................................... 79 date summer-time ........................................................................ 81 date timezone............................................................................... 80
Default priority .............................................................................. 46 delete............................................................................................ 95 description .................................................................................. 127
DiffServ......................................................................................... 46 dir ................................................................................................. 94 disable .......................................................................................... 71 do ................................................................................................. 73 downlink allowed uplink-domain................................................. 120
Downloading a Configuration File .............................................. 244
Dynamic MAC address learning................................................... 27
ï¼¥ egress......................................................................................... 153 enable........................................................................................... 70 enable password .......................................................................... 84
Event Logs ................................................................................. 253 exit................................................................................................ 72
J
Jumbo Frame Support ................................................................. 28
L lacp port-priority ..........................................................................116 lacp system-priority .....................................................................115
LFS............................................................................................... 31 line................................................................................................ 65
Link Aggregation .......................................................................... 32
Link Aggregation Configuration Commands............................... 109
Link Fault Signaling...................................................................... 31
Link Pass Through ....................................................................... 31 link-aggregation...........................................................................113 link-aggregation load-balance ip-hash-selection.........................116
285/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide link-pass-through........................................................................ 132
List of Event Logs....................................................................... 254
List of MIBs................................................................................. 275 log send...................................................................................... 230 logout / quit................................................................................... 73 ls ................................................................................................. 94
ï¼ password (Administrator EXEC mode)......................................... 77 password (Operator EXEC mode)................................................ 76 path costs ..................................................................................... 39 ping............................................................................................... 83
Port Mirroring................................................................................ 30
Port Mirroring Setup Commands................................................ 164
Port Roles Based on Spanning Tree ............................................ 40
Port Security................................................................................. 29
Port-Based VLAN ......................................................................... 41 port-security................................................................................ 131 port-vlan-id ................................................................................. 154
Preparing the TFTP Server ........................................................ 244 rename ......................................................................................... 96 reset ............................................................................................. 78
Resetting startup-config to Factory Defaults .............................. 250
Restoring Factory Defaults................................................. 250, 251
Reviewing Fault Logs................................................................. 242
Reviewing Log Messages .......................................................... 241
RMON .......................................................................................... 54 rmon alarm ................................................................................. 220 rmon collection history ............................................................... 219 rmon event ................................................................................. 222
RMON Setup Commands .......................................................... 217 running-config .............................................................................. 15
MAC Address Table Management................................................ 27 management LAN interface Configuration Commands................ 58 management-lan dns-server ........................................................ 60 management-lan domain ............................................................. 61 management-lan ip ...................................................................... 59
Managing Group Members .......................................................... 50
Managing the Device.................................................................. 237
Mapping to output queues............................................................ 46
Message Format for Forwarding syslog ..................................... 273 mirror .......................................................................................... 165 monitor dataflow ......................................................................... 198 monitor error............................................................................... 200 monitor framesize-traffic-counts ................................................. 190 monitor qos-priority-traffic-bytes................................................. 192 monitor qos-priority-traffic-counts............................................... 194 monitor traffic-bytes.................................................................... 186 monitor traffic-counts.................................................................. 188 monitor vlan-traffic-bytes ............................................................ 196 monitor vlan-traffic-counts .......................................................... 197 multicast-forwarding ................................................................... 134 multiple-tag VLAN ........................................................................ 43
ï¼®
No Form of Commands ................................................................ 18
Notes on Link Aggregation ........................................................... 35 ntp-server ..................................................................................... 86
O
Operating Environment for the CLI .............................................. 12
Overview of Event Logs ............................................................. 253
ï¼°
ï¼±
QoS .............................................................................................. 46 qos bandwidth ............................................................................ 163 qos default-priority...................................................................... 160 qos egress-scheduling ............................................................... 162
QoS Setup Commands .............................................................. 159 qos-map priority.......................................................................... 160
Quality of Service ......................................................................... 46
ï¼²
Redirecting show Command Output ............................................ 19
Registering Group Members ........................................................ 48 remote-host .................................................................................. 63
Removing Group Members .......................................................... 49
ï¼³ save maintenance ...................................................................... 231
Scrolling Down or Up a Line or a Page ........................................ 17
Selecting Firmware .................................................................... 246
Selecting the Alternate Firmware Image .................................... 250
Serial/Telnet Configuration Commands........................................ 65
Setting Up the Serial Interface ..................................................... 22 shortcut key.................................................................................. 17 show account ............................................................................... 74 show bridge ................................................................................ 100 show bridge mac-address-table ................................................. 101 show history ................................................................................. 71 show interface ............................................................................ 121 show ip snooping ....................................................................... 166 show link-aggregation ................................................................ 109 show log ..................................................................................... 229 show maintenance ..................................................................... 231 show mirror................................................................................. 164 show port-description ................................................................. 124 show qos .................................................................................... 159 show remote-host......................................................................... 58 show rmon.................................................................................. 217 show running-config ..................................................................... 87 show running-config (redirect)...................................................... 88 show snmp-server...................................................................... 212 show spanning-tree .................................................................... 135 show ssh-host-key ....................................................................... 68 show startup-config ...................................................................... 89 show startup-config (redirect)....................................................... 90 show statistics dataflow.............................................................. 209 show statistics error.................................................................... 210 show statistics framesize-traffic-counts...................................... 204 show statistics qos-priority-traffic-bytes...................................... 205 show statistics qos-priority-traffic-counts.................................... 206 show statistics traffic-bytes......................................................... 202 show statistics traffic-counts....................................................... 203 show statistics vlan-traffic-bytes................................................. 207 show statistics vlan-traffic-counts............................................... 208 show system information............................................................ 226 show system status .................................................................... 224 show uplink .................................................................................117 show vlan ................................................................................... 150 shutdown (Administrator exec mode)......................................... 125 shutdown (Global configuration mode) ...................................... 130 shutdown (Interface edit mode).................................................. 130
SNMP Agent................................................................................. 54
SNMP Configuration..................................................................... 25
SNMP Setup Commands ........................................................... 212
SNMP Traps ............................................................................... 274 snmp-server access ................................................................... 215 snmp-server contact................................................................... 214 snmp-server location.................................................................. 213 snmp-server trap ........................................................................ 216
Spanning Tree Protocol................................................................ 39
Spanning Tree Protocol (STP) Configuration Commands.......... 135
Spanning Tree Protocol Port States ............................................. 40 spanning-tree ............................................................................. 140 spanning-tree forward-time ........................................................ 144 spanning-tree hello-time............................................................. 142 spanning-tree max-age .............................................................. 143 spanning-tree path-cost-default.................................................. 146 spanning-tree portfast ................................................................ 147 spanning-tree portfast bpdu-filter ............................................... 149 spanning-tree portfast bpdu-guard ............................................. 148 spanning-tree portfast errdisable-timeout................................... 148
286/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide spanning-tree port-path-cost ...................................................... 145 spanning-tree port-priority .......................................................... 145 spanning-tree priority.................................................................. 141
SSH Connection via the Management LAN Interface .................. 24 ssh-auto-key-generation .............................................................. 67 ssh-server..................................................................................... 67 startup-config................................................................................ 15
Static multicast address................................................................ 28
Static unicast address .................................................................. 28
Statistics Commands.................................................................. 185
Store-and-forward switching mode............................................... 27
Storm Control ............................................................................... 29 storm-control .............................................................................. 129
STP .............................................................................................. 39 suppress-address-learning......................................................... 129
SVL............................................................................................... 27
Switch Basic Configuration commands........................................ 99
Switch Port Configuration Commands ....................................... 121
Switching Mode ............................................................................ 27
System Basic Operation Commands ........................................... 70
System Maintenance Commands .............................................. 228
System Operation Display Commands ...................................... 224 system shutdown.......................................................................... 78
ï¼´
Tag-Based VLAN.......................................................................... 42
Telnet Connection via the Management LAN Interface................ 23 telnet-server ................................................................................. 67 terminal pager .............................................................................. 65 terminal window............................................................................ 69 terminal-timeout............................................................................ 66 tftp get .......................................................................................... 97 tftp put .......................................................................................... 98 tftp put-maintenance................................................................... 232
The Number of Ports That Require Linkup................................... 34
Traffic Statistics ............................................................................ 53
Troubleshooting.......................................................................... 249
ï¼µ update-system............................................................................ 234
Updating Firmware..................................................................... 245
Uplink Filter .................................................................................. 36
Uplink Filter Commands..............................................................117 uplink-domain..............................................................................118
Uploading a Configuration File................................................... 244
Uploading/Downloading a Configuration File ............................. 244 user-vlan-protocol-id .................................................................. 156
Using the CLI ..........................................................................11, 16
V
Verifying Hardware Status.......................................................... 238
Verifying System Status ............................................................. 241
Verifying the Device Operations................................................. 238
Verifying the Device Status Change........................................... 243
Virtual LAN ................................................................................... 41
Virtual LAN (VLAN) Setup Commands....................................... 150 vlan............................................................................................. 151
VLAN ............................................................................................ 41
VLAN tag ...................................................................................... 42 vlan-member allowed ................................................................. 155 vlan-statistics collection.............................................................. 158
ï¼·
Workflow for Initial Setup of the Device........................................ 22
287/288
All Rights Reserved, Copyright (C) PFU LIMITED 2008
XG2000 series User's Guide
P3N1-E152-01ENZ0
Date of Issue: March 2008
Issuing authority: PFU LIMITED
The contents of this manual may be updated without notice.
PFU assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual.
Contents of this manual are not to be reproduced without permission from PFU
advertisement
Key Features
- 20-port 10 Gigabit Ethernet
- High throughput and low latency
- Compact design
- Layer 2 switching
- VLAN support
- Link aggregation
- Spanning Tree Protocol (STP)
- Quality of Service (QoS)
- IGMP Snooping
- Network Management
Frequently Answers and Questions
What is the XG2000 series?
What is the purpose of this guide?
What are some key features of the XG2000 series?
What are the models included in the XG2000 series?
What knowledge is required to use this guide?
Related manuals
advertisement
Table of contents
- 2 Preface
- 3 About this Manual
- 4 Contents
- 9 Features and Functions
- 10 1.1 Features
- 11 Using the CLI
- 12 2.1 Overview of the CLI
- 12 2.1.1 Operating Environment for the CLI
- 13 2.1.2 Command Modes and Mode Switching
- 15 2.1.3 startup-config and running-config
- 16 2.2 Using the CLI
- 16 2.2.1 How to Enter Commands
- 16 2.2.2 Context-Sensitive Help
- 17 2.2.3 Command Completion
- 17 2.2.4 Command Abbreviation
- 17 2.2.5 Command-Line Error Messages
- 17 2.2.6 Scrolling Down or Up a Line or a Page
- 18 2.2.7 Command History
- 18 2.2.8 Aborting Command
- 18 2.2.9 No Form of Commands
- 19 2.2.10 Filtering show Command Output
- 19 2.2.11 Redirecting show Command Output
- 20 2.2.12 Using the monitor Command
- 21 Installation
- 22 3.1 Workflow for Initial Setup of the Device
- 22 3.1.1 Setting Up the Serial Interface
- 23 3.1.2 Configure Management LAN Interface
- 23 3.1.3 Telnet Connection via the Management LAN Interface (Optional)
- 24 3.1.4 SSH Connection via the Management LAN Interface (Optional)
- 25 3.1.5 SNMP Configuration (Optional)
- 26 Switch Functions and their Configuration
- 27 4.1 Basic Switch Functions
- 27 4.1.1 Switching Mode
- 27 4.1.2 MAC Address Table Management
- 28 4.1.3 Jumbo Frame Support
- 28 4.1.4 Flow Control
- 29 4.1.5 Storm Control
- 29 4.1.6 Port Security
- 29 4.1.7 Ingress Rate Control
- 30 4.2 Port Mirroring
- 31 4.3 Link Pass Through
- 32 4.4 Link Aggregation
- 33 4.4.1 Configuring Link Aggregation
- 34 4.4.2 Frame Distribution Methods in Link Aggregation
- 34 4.4.3 The Number of Ports That Require Linkup
- 35 4.4.4 Notes on Link Aggregation
- 36 4.5 Uplink Filter
- 39 4.6 Spanning Tree Protocol (STP)
- 40 4.6.1 Port Roles Based on Spanning Tree
- 40 4.6.2 Spanning Tree Protocol Port States
- 40 4.6.3 Configuring Spanning Tree
- 41 4.7 VLAN
- 41 4.7.1 Port-Based VLAN
- 42 4.7.2 Tag-Based (IEEE802.1Q) VLAN
- 43 4.7.3 Multiple VLAN
- 46 4.8 Quality of Service (QoS)
- 47 4.9 IGMP Snooping
- 48 4.9.1 Registering Group Members
- 49 4.9.2 Removing Group Members
- 50 4.9.3 Managing Group Members
- 51 4.9.4 IGMP Querier
- 52 4.9.5 Configuring IGMP Snooping
- 53 4.10 Network Management
- 53 4.10.1 Traffic Statistics
- 54 4.10.2 SNMP Agent
- 54 4.10.3 RMON
- 55 Command Reference
- 56 5.1 About Command Reference
- 56 5.1.1 Command System
- 57 5.1.2 Configuration of Command Reference
- 58 5.2 Management LAN Interface Configuration Commands
- 58 5.2.1 show remote-host
- 59 5.2.2 management-lan ip
- 60 5.2.3 management-lan dns-server
- 61 5.2.4 management-lan domain
- 62 5.2.5 hostname
- 63 5.2.6 remote-host
- 65 5.3 Serial/Telnet/ssh Configuration Commands
- 65 5.3.1 terminal pager
- 65 5.3.2 line
- 66 5.3.3 baud-rate
- 66 5.3.4 terminal timeout
- 67 5.3.5 telnet-server
- 67 5.3.6 ssh-server
- 67 5.3.7 ssh-auto-key-generation
- 68 5.3.8 show ssh-host-key
- 68 5.3.9 generate ssh-host-key
- 69 5.3.10 terminal window
- 70 5.4 System Basic Operation Commands
- 70 5.4.1 enable
- 71 5.4.2 show history
- 71 5.4.3 disable
- 72 5.4.4 configure terminal
- 72 5.4.5 exit
- 73 5.4.6 logout / quit
- 73 5.4.7 do
- 74 5.4.8 help
- 74 5.4.9 show account
- 75 5.4.10 account
- 76 5.4.11 password (Operator EXEC mode)
- 77 5.4.12 password (Administrator EXEC mode)
- 78 5.4.13 reset
- 78 5.4.14 system shutdown
- 79 5.4.15 date
- 79 5.4.16 date set
- 80 5.4.17 date timezone
- 81 5.4.18 date summer-time
- 83 5.4.19 ping
- 84 5.4.20 enable password
- 85 5.4.21 banner
- 86 5.4.22 ntp-server
- 87 5.5 Configuration File Operation Commands
- 87 5.5.1 copy running-config startup-config
- 87 5.5.2 show running-config
- 88 5.5.3 show running-config (redirect)
- 89 5.5.4 show startup-config
- 90 5.5.5 show startup-config (redirect)
- 92 5.5.6 copy startup-config
- 94 5.5.7 dir/ls
- 95 5.5.8 delete
- 96 5.5.9 rename
- 97 5.5.10 tftp get
- 98 5.5.11 tftp put
- 99 5.6 Switch Basic Configuration Commands
- 99 5.6.1 clear bridge mac-address-table
- 100 5.6.2 show bridge
- 101 5.6.3 show bridge mac-address-table
- 102 5.6.4 bridge forward-mode
- 103 5.6.5 bridge jumbo-frame
- 104 5.6.6 bridge learn-mode
- 105 5.6.7 bridge mac-address-table
- 107 5.6.8 bridge mac-address-table filter
- 108 5.6.9 bridge aging-time
- 109 5.7 Link Aggregation Configuration Commands
- 109 5.7.1 show link-aggregation
- 113 5.7.2 link-aggregation
- 115 5.7.3 lacp system-priority
- 116 5.7.4 lacp port-priority
- 116 5.7.5 link-aggregation load-balance ip-hash-selection
- 117 5.8 Uplink Filter Commands
- 117 5.8.1 show uplink
- 118 5.8.2 uplink-domain
- 120 5.8.3 downlink allowed uplink-domain
- 121 5.9 Switch Port Configuration Commands
- 121 5.9.1 show interface
- 124 5.9.2 show port-description
- 125 5.9.3 shutdown (Administrator exec mode)
- 125 5.9.4 clear violation
- 126 5.9.5 interface port
- 127 5.9.6 description
- 128 5.9.7 flowcontrol
- 129 5.9.8 storm-control
- 129 5.9.9 suppress-address-learning
- 130 5.9.10 shutdown (Interface edit mode)
- 130 5.9.11 shutdown (Global configuration mode)
- 131 5.9.12 port-security
- 132 5.9.13 link-pass-through
- 133 5.9.14 ingress-bandwidth
- 134 5.9.15 multicast-forwarding
- 135 5.10 Spanning Tree Protocol (STP) Configuration Commands
- 135 5.10.1 show spanning-tree
- 140 5.10.2 spanning-tree
- 141 5.10.3 spanning-tree priority
- 142 5.10.4 spanning-tree hello-time
- 143 5.10.5 spanning-tree max-age
- 144 5.10.6 spanning-tree forward-time
- 145 5.10.7 spanning-tree port-priority
- 145 5.10.8 spanning-tree port-path-cost
- 146 5.10.9 spanning-tree path-cost-default
- 147 5.10.10 spanning-tree portfast
- 148 5.10.11 spanning-tree portfast bpdu-guard
- 148 5.10.12 spanning-tree portfast errdisable-timeout
- 149 5.10.13 spanning-tree portfast bpdu-filter
- 150 5.11 Virtual LAN (VLAN) Setup Commands
- 150 5.11.1 show vlan
- 151 5.11.2 vlan
- 152 5.11.3 Interface vlan
- 153 5.11.4 egress
- 154 5.11.5 port-vlan-id
- 155 5.11.6 vlan-member allowed
- 156 5.11.7 user-vlan-protocol-id
- 156 5.11.8 ingress-filter no-vlan-member-frame
- 157 5.11.9 ingress-filter tagged-frame
- 157 5.11.10 ingress-filter untagged-frame
- 158 5.11.11 vlan-statistics collection
- 159 5.12 QoS Setup Commands
- 159 5.12.1 show qos
- 160 5.12.2 qos default-priority
- 160 5.12.3 qos-map priority
- 161 5.12.4 bridge diffserv-tos
- 162 5.12.5 qos egress-scheduling
- 163 5.12.6 qos bandwidth
- 164 5.13 Port Mirroring Setup Commands
- 164 5.13.1 show mirror
- 165 5.13.2 mirror
- 166 5.14 IGMP Snooping Setup Commands
- 166 5.14.1 show ip snooping
- 168 5.14.2 ip snooping protocol
- 169 5.14.3 ip snooping vlan
- 170 5.14.4 ip snooping vlan max-group
- 171 5.14.5 ip snooping vlan mrouter
- 172 5.14.6 ip snooping vlan group-member-interval
- 173 5.14.7 ip snooping vlan fast-leave
- 174 5.14.8 ip snooping vlan last-member-query-interval
- 175 5.14.9 ip snooping vlan send-query-count
- 176 5.14.10 ip snooping vlan querier
- 177 5.14.11 ip snoop
- 178 5.14.12 ip snooping max-group
- 179 5.14.13 ip snooping mrouter
- 180 5.14.14 ip snooping group-member-interval
- 181 5.14.15 ip snooping fast-leave
- 182 5.14.16 ip snooping last-member-interval
- 183 5.14.17 ip snooping send-query-count
- 184 5.14.18 ip snooping querier
- 185 5.15 Statistics Commands
- 186 5.15.1 monitor traffic-bytes
- 188 5.15.2 monitor traffic-counts
- 190 5.15.3 monitor framesize-traffic-counts
- 192 5.15.4 monitor qos-priority-traffic-bytes
- 194 5.15.5 monitor qos-priority-traffic-counts
- 196 5.15.6 monitor vlan-traffic-bytes
- 197 5.15.7 monitor vlan-traffic-counts
- 198 5.15.8 monitor dataflow
- 200 5.15.9 monitor error
- 202 5.15.10 show statistics traffic-bytes
- 203 5.15.11 show statistics traffic-counts
- 204 5.15.12 show statistics framesize-traffic-counts
- 205 5.15.13 show statistics qos-priority-traffic-bytes
- 206 5.15.14 show statistics qos-priority-traffic-counts
- 207 5.15.15 show statistics vlan-traffic-bytes
- 208 5.15.16 show statistics vlan-traffic-counts
- 209 5.15.17 show statistics dataflow
- 210 5.15.18 show statistics error
- 211 5.15.19 clear statistics
- 212 5.16 SNMP Setup Commands
- 212 5.16.1 show snmp-server
- 213 5.16.2 snmp-server location
- 214 5.16.3 snmp-server contact
- 215 5.16.4 snmp-server access
- 216 5.16.5 snmp-server trap
- 217 5.17 RMON Setup Commands
- 217 5.17.1 show rmon
- 219 5.17.2 rmon collection history
- 220 5.17.3 rmon alarm
- 222 5.17.4 rmon event
- 224 5.18 System Operation Display Commands
- 224 5.18.1 show system status
- 226 5.18.2 show system information
- 228 5.19 System Maintenance Commands
- 228 5.19.1 clear log
- 229 5.19.2 show log
- 230 5.19.3 log send
- 231 5.19.4 save maintenance
- 231 5.19.5 show maintenance
- 232 5.19.6 tftp put-maintenance
- 233 5.19.7 clear maintenance
- 234 5.19.8 update-system
- 236 5.19.9 boot-system
- 237 Managing the Device
- 238 6.1 Verifying the Device Operations
- 238 6.1.1 Verifying Hardware Status
- 241 6.1.2 Verifying System Status
- 241 6.1.3 Reviewing Log Messages
- 244 6.2 Uploading/Downloading a Configuration File
- 244 6.2.1 Preparing the TFTP Server
- 244 6.2.2 Uploading a Configuration File
- 244 6.2.3 Downloading a Configuration File
- 245 6.3 Updating Firmware
- 245 6.3.1 Updating Firmware
- 246 6.3.2 Selecting Firmware
- 247 6.4 Extracting of Maintenance Information
- 247 6.4.1 Procedure for Extracting Maintenance Information when a System /Subsystem Failure Occurred
- 248 6.4.2 Procedure for Extracting Maintenance Information when an endless System Loop Occurred
- 248 6.4.3 Procedure for Extracting Maintenance Information when a Malfunction Occurs
- 249 Troubleshooting
- 250 7.1 Restoring Factory Defaults
- 250 7.1.1 Resetting startup-config to Factory Defaults
- 250 7.1.2 Selecting the Alternate Firmware Image
- 251 7.1.3 Restoring Factory Defaults
- 253 Overview of Event Logs
- 254 List of Event Logs
- 268 update (Firmware Update: 7500-7999)
- 271 snmp (SNMP Control: 8500-8599)
- 272 ntp (NTP Control: 8600-8699)
- 273 Message Format for Forwarding syslog