Hilti DEG 125-D/-P, DEG 150-D/-P angle grinder Bedienungsanleitung

Hilti DEG 125-D/-P, DEG 150-D/-P angle grinder Bedienungsanleitung

Below you will find brief information for angle grinder DEG 125-D/-P, angle grinder DEG 150-D/-P. These angle grinders are powerful tools designed for cutting and grinding a wide range of materials, including metal and mineral materials. They feature a range of safety features to protect the user, including a guard, a side handle, and a restart interlock. The tool also has a constant speed electronics system that keeps the speed constant even when the tool is under load.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Hilti DEG 125-D/-P Operating Instructions | Manualzz
DEG 125-D/-P /
DEG 150-D/-P
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
Bedienungsanleitung
de
Operating instructions
en
Mode d’emploi
fr
Manual de instrucciones
es
Istruzioni d’uso
it
Gebruiksaanwijzing
nl
Brugsanvisning
da
Bruksanvisning
no
Bruksanvisning
sv
Käyttöohje
fi
Manual de instruções
pt
Οδηγιες χρησεως
el
Инструкция по зксплуатации
ru
Lietošanas pamācība
lv
Instrukcija
lt
Kasutusjuhend
et
1
.ZLN/RFN
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
2
3
4
5
6
8
7
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
9
10
11
12
PP
•PP
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
13
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
Hilti DEG 125-D/-P, DEG 150-D/-P, Pos.1, Art. Nr.285965/A3, 18.09.2013
ORIGINAL OPERATING INSTRUCTIONS
DEG 125‑D / DEG 125‑P, DEG 150‑D / DEG 150‑P angle grinder
en
It is essential that the operating instructions
are read before the power tool is operated for
the first time.
Always keep these operating instructions together with the power tool.
Ensure that the operating instructions are
with the power tool when it is given to other
persons.
Contents
1 General information
2 Description
3 Accessories, consumables
4 Technical data
5 Safety instructions
6 Before use
7 Operation
8 Care and maintenance
9 Troubleshooting
10 Disposal
11 Manufacturer’s warranty - tools
12 EC declaration of conformity (original)
Page
18
19
22
23
24
28
29
31
31
32
32
33
1 These numbers refer to the corresponding illustrations. The illustrations can be found on the fold-out cover
pages. Keep these pages open while studying the operating instructions.
In these operating instructions, the designation “the
power tool” always refers to the DEG 125 or DEG 150
angle grinder.
Operating controls and parts 1
@ Ventilation slots
; On / off switch (hold to run)
= Vibration-absorbing side handle
% Spindle lockbutton
& Guard release button
( Spindle
) Guard
+ Clamping flange with O-ring
§ Abrasive cutting disc / abrasive grinding disc
/ Clamping nut
: Kwik‑Lock quick-release clamping nut (optional)
· Wrench
1 General information
1.1 Safety notices and their meaning
DANGER
Draws attention to imminent danger that will lead to
serious bodily injury or fatality.
WARNING
Draws attention to a potentially dangerous situation that
could lead to serious personal injury or fatality.
CAUTION
Draws attention to a potentially dangerous situation that
could lead to slight personal injury or damage to the
equipment or other property.
NOTE
Draws attention to an instruction or other useful information.
18
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
1.2 Explanation of the pictograms and other
information
Warning signs
General
warning
Warning:
electricity
Hilti DEG 125-D/-P, DEG 150-D/-P, Pos.1, Art. Nr.285965/A3, 18.09.2013
Obligation signs
Wear eye
protection
Wear a hard
hat
Wear ear
protection
Wear
protective
gloves
Location of identification data on the power tool
The type designation, item number, year of manufacture
and technical status can be found on the type identification plate on the machine or tool. The serial no. can be
found on the left side of the motor housing. Make a note
of this data in your operating instructions and always refer
to it when making an enquiry to your Hilti representative
or service department.
Type:
Serial no.:
Wear
breathing
protection
Symbols
Read the
operating
instructions
before use
Return waste
material for
recycling.
Volts
Amps
Alternating
current
Rated speed
Revolutions
per minute
Revolutions
per minute
Diameter
Double
insulated
2 Description
2.1 Use of the product as directed
The power tool is designed for cutting and grinding metal and mineral materials without use of water. Use of a guide
carriage is mandatory for cutting stone.
The working environment may be as follows: construction site, workshop, renovation, conversion or new construction.
The power tool may be operated only when connected to a power supply providing a voltage and frequency in
compliance with the information given on its type identification plate.
Working with metals: Cutting, grinding.
Working with mineral materials: Cutting and slitting using the corresponding guard (DC-EX), grinding using the
corresponding guard (DG-EX).
Use only discs (abrasive grinding discs, abrasive cutting discs, etc.) that are approved for use at a speed of at least
11000/min for a diameter of 125 mm and at least 9300/min for a diameter of 150 mm, with a maximum thickness of
6.4 mm (grinding discs) or 2.5 mm (cutting discs).
Use only synthetic resin-bonded, fiber-reinforced grinding discs or cutting discs approved for use at a permissible
peripheral speed of at least 80 m/sec.
The power tool may be used only for dry cutting or grinding.
When grinding stone, a vacuum cleaner equipped with a stone dust filter, e.g. a suitable Hilti vacuum cleaner, must be
used.
19
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
en
Hilti DEG 125-D/-P, DEG 150-D/-P, Pos.1, Art. Nr.285965/A3, 18.09.2013
en
Nationally applicable industrial safety regulations must be observed.
Working on materials hazardous to the health (e.g. asbestos) is not permissible.
Modification of the power tool or tampering with its parts is not permissible.
To avoid the risk of injury, use only genuine Hilti accessories and insert tools.
Observe the information printed in the operating instructions concerning operation, care and maintenance.
The power tool is designed for professional use and may be operated, serviced and maintained only by trained,
authorized personnel. This personnel must be informed of any special hazards that may be encountered. The power
tool and its ancillary equipment may present hazards when used incorrectly by untrained personnel or when used not
as directed.
Take the influences of the surrounding area into account. Do not use the power tool or appliance where there is a risk
of fire or explosion.
2.2 The items supplied in the cardboard box are:
1
Power tool with guard
1
Front cover (optional)
1
Kwik‑Lock quick-release clamping nut (optional)
1
1
1
1
1
1
Vibration-absorbing side handle
Flange
Nut
Wrench
Operating instructions
Cardboard box
2.3 Starting current limitation
The electronic starting current limiter reduces the starting current drawn by the power tool and thus prevents the
mains fuse blowing. It also allows the power tool to start smoothly, without a jolt.
2.4 Constant-speed electronics
Electronic speed control keeps running speed almost constant irrespective of whether the power tool is idling or
running under load. Constant running speed helps ensure maximum efficiency.
2.5 ATC (Active Torque Control)
The electronics in the power tool detect situations where there is a risk of the disc sticking and prevent further rotation
of the drive spindle by switching the power tool off (does not prevent kickback). The switch must be released and
pressed again to restart the power tool.
2.6 Restart interlock
The power tool does not restart by itself when the switch is locked in the on-position and the power returns after an
interruption in the electric supply. The switch must first be released and then pressed again to restart.
2.7 Temperature-dependent motor protection
The temperature-dependent motor protection system prevents the tool overheating by monitoring current input and
motor temperature.
In the event of motor overload due to application of excessive pressure to the disc, performance will drop noticeably
or the tool may stop running (avoid stalling the tool in this way).
Permissible tool overload cannot be given as a specific value as it depends on the temperature of the motor.
In the event of the tool being overloaded, release the pressure applied and allow the tool to run under no load for
approx. 30 seconds.
2.8 Using extension cords
Use only extension cords of a type approved for the application and with conductors of adequate cross section. The
power tool may otherwise loose performance and the extension cord may overheat. Check the extension cord for
damage at regular intervals. Replace damaged extension cords.
20
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
Hilti DEG 125-D/-P, DEG 150-D/-P, Pos.1, Art. Nr.285965/A3, 18.09.2013
Recommended minimum conductor cross section and max. cable lengths
Conductor cross
section
1.5 mm²
Mains voltage 100V
Mains voltage 110120 V
Mains voltage 220240 V
2 mm²
2.5 mm²
30 m
20 m
30 m
50 m
3.5 mm²
14 AWG
12 AWG
75 ft
125 ft
50 m
40 m
50 m
100 m
en
Do not use extension cords with 1.25 mm² or 16 AWG conductor cross sections.
2.9 Using extension cords outdoors
When working outdoors, use only extension cords that are approved and correspondingly marked for this application.
2.10 Using a generator or transformer
This power tool may be powered by a generator or transformer when the following conditions are fulfilled: The unit
must provide a power output in watts of at least twice the value printed on the type identification plate on the power
tool. The operating voltage must remain within +5% and -15% of the rated voltage at all times, frequency must be in
the 50 – 60 Hz range and never above 65 Hz, and the unit must be equipped with automatic voltage regulation and
starting boost.
Never operate other power tools or appliances from the generator or transformer at the same time. Switching other
power tools or appliances on and off may cause undervoltage and / or overvoltage peaks, resulting in damage to the
power tool.
2.11 DG-EX 125/5" dust removal hood for grinding 2
The tool is suitable only for occasional use with diamond cup wheels for grinding mineral materials.
CAUTION
Use of this guard for working on metal is not permissible.
NOTE
It is recommended that a dust removal system consisting of matched components, i.e. dust removal hood and a
suitable Hilti vacuum cleaner, are used for grinding mineral materials, such as concrete or stone. These serve to
protect the operator and increase the life of the power tool and disc used.
2.12 DC‑EX 125/5"‑M dust removal hood with guide carriage for cutting and slitting 3
Cutting and slitting work on mineral materials may be carried out only when the power tool is equipped with a dust
removal hood with guide carriage.
CAUTION
Use of this guard for working on metal is not permissible.
NOTE
It is recommended that a dust removal system consisting of matched components, i.e. dust removal hood and a
suitable Hilti vacuum cleaner, are used for cutting and slitting mineral materials, such as concrete or stone. These
serve to protect the operator and increase the life of the power tool and disc used.
2.13 DC‑EX 125/5"‑C compact dust removal hood for cutting 4
For cutting masonry and concrete.
CAUTION
Use of this guard for working on metal is not permissible.
NOTE
It is recommended that a dust removal system consisting of matched components, i.e. dust removal hood and a
suitable Hilti vacuum cleaner, are used for cutting and slitting mineral materials, such as concrete or stone. These
serve to protect the operator and increase the life of the power tool and disc used.
21
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
Hilti DEG 125-D/-P, DEG 150-D/-P, Pos.1, Art. Nr.285965/A3, 18.09.2013
2.14 Guard with side cover 5
CAUTION
When grinding with straight grinding discs and cutting with cutting discs in metalworking applications, use the
guard with cover plate.
2.15 Front cover for guard (DEG 125-D and DEG 125-P only) 7
en
CAUTION
When grinding with straight grinding discs and cutting with cutting discs in metalworking applications, use the
guard with front cover.
3 Accessories, consumables
Accessories for the DEG 125 and DEG 150
Designation
Description
Dust removal hood for grinding
DG-EX 125/5"
Dust removal hood with guide carriage for cutting /
slitting
DC‑EX 125/5"‑M
Accessories for the DEG 125
Designation
Description
Compact dust removal hood
DC-EX 125/5" C
Discs with a max. diameter of 125 mm and 11000/min or, respectively, 150 mm and 9300/min, and a peripheral
speed of 80 m/sec, a maximum thickness of 6.4 mm (abrasive grinding discs) or 2.5 mm (abrasive cutting
discs).
Discs
Application
Designation
Material
Abrasive cutting disc
Cutting, slitting
AC‑D
metal
mineral
Diamond cutting disc
Cutting, slitting
DC‑D
Abrasive grinding disc
Rough grinding
AG‑D, AF‑D, AN‑D
metal
Diamond grinding disc
Rough grinding
DG‑CW
mineral
Assignment of discs to the equipment used
Item
Equipment
AC‑D
AG-D
AF-D
AN-D
DG‑CW
DC‑D
A
Guard
X
B
Front cover for DEG
125-D/P only (optional
for A)
Guard with cover plate
(optional for A, B)
DG‑EX 125/5" surface
guard
DC‑EX 125/5"-C compact guard (in combination with A)
DG‑EX 125/5"M mineral cutting guard
DC‑EX SL cutting adapter (in combination
with F)
Side handle
X
X
-
X
-
X
-
X
-
X
-
X
-
-
-
-
X
-
-
-
-
X
-
-
-
-
-
-
X
-
-
-
-
-
X
-
-
-
-
-
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
C
D
E
F
G
H
I
K
22
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
DC BG 125 hoop
handle (optional for H)
Clamping nut
Hilti DEG 125-D/-P, DEG 150-D/-P, Pos.1, Art. Nr.285965/A3, 18.09.2013
Item
Equipment
AC‑D
AG-D
AF-D
AN-D
DG‑CW
DC‑D
L
Clamping flange
X
X
X
X
X
M
Kwick-Lock (optional
for K)
X
X
X
X
X
-
X
en
4 Technical data
Right of technical changes reserved.
Tool
DEG 125-D/-P
DEG 150-D/-P
Rated current / power input
Rated voltage
220 /230 V: 6.7 A / 1,400 W
Rated voltage 110 V: 12.2 A /
1,200 W
50 / 60 Hz
Rated voltage
220 /230 V: 6.7 A / 1,400 W
Rated voltage 110 V: 12.2 A /
1,200 W
50 / 60 Hz
Rated speed
11,000/min
9,300/min
Max. washer diameter
Diameter 125 mm
Diameter 150 mm
Dimensions (L x H x W) without
hood
Weight in accordance with EPTA
procedure 01/2003
360 mm x 103 mm x 80 mm
360 mm x 103 mm x 80 mm
2.3 kg
2.4 kg
Rated frequency
Information about the power tool and applications
Drive spindle thread (arbor size)
M 14
Spindle length
22 mm
Protection class
Protection class II (double insulated)
NOTE
The vibration emission level given in this information sheet has been measured in accordance with a standardised test
given in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment
of exposure. The declared vibration emission level represents the main applications of the tool. However if the tool is
used for different applications, with different accessories or poorly maintained, the vibration emission may differ. This
may significantly increase the exposure level over the total working period. An estimation of the level of exposure to
vibration should also take into account the times when the tool is switched off or when it is running but not actually
doing the job. This may significantly reduce the exposure level over the total working period. Identify additional safety
measures to protect the operator from the effects of vibration such as: maintain the tool and the accessories, keep
the hands warm, organisation of work patterns.
Noise information (as perEN 60745‑1):
Typical A-weighted noise power level
100 dB (A)
Typical A-weighted emission sound pressure level
89 dB (A)
Uncertainty for the given sound level
3 dB (A)
Vibration information in accordance with EN 60745
Triaxial vibration value (vibration vector sum), DEG 125D/-P
Surface grinding with the standard side handle, ah,AG
Measured in accordance with EN 60745‑2‑3
11.3 m/s²
Surface grinding with the vibration absorbing side
handle, ah,AG
7.0 m/s²
Uncertainty (K)
1.5 m/s²
Surface grinding with the hoop handle, ah,AG
9.9 m/s²
23
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
Hilti DEG 125-D/-P, DEG 150-D/-P, Pos.1, Art. Nr.285965/A3, 18.09.2013
Triaxial vibration value (vibration vector sum), DEG 150D/-P
Surface grinding with the standard side handle, ah,AG
8.9 m/s²
Surface grinding with the vibration absorbing side
handle, ah,AG
7.1 m/s²
Uncertainty (K)
1.5 m/s²
Additional information
Other applications, such as cutting, may produce vibration values that deviate from the given values.
Surface grinding with the hoop handle, ah,AG
en
Measured in accordance with EN 60745‑2‑3
8.7 m/s²
5 Safety instructions
protected supply. Use of an RCD reduces the risk
of electric shock.
5.1 General Power Tool Safety Warnings
a)
WARNING
Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result
in electric shock, fire and/or serious injury. Save all
warnings and instructions for future reference.
The term “power tool” in the warnings refers to
your mains-operated (corded) power tool or batteryoperated (cordless) power tool.
5.1.1 Work area safety
Keep work area clean and well lit. Cluttered or dark
areas invite accidents.
b) Do not operate power tools in explosive atmospheres, such as in the presence of flammable
liquids, gases or dust. Power tools create sparks
which may ignite the dust or fumes.
c) Keep children and bystanders away while operating a power tool. Distractions can cause you to lose
control.
a)
5.1.2 Electrical safety
Power tool plugs must match the outlet. Never
modify the plug in any way. Do not use any adapter plugs with earthed (grounded) power tools.
Unmodified plugs and matching outlets will reduce
risk of electric shock.
b) Avoid body contact with earthed or grounded
surfaces, such as pipes, radiators, ranges and
refrigerators. There is an increased risk of electric
shock if your body is earthed or grounded.
c) Do not expose power tools to rain or wet conditions. Water entering a power tool will increase the
risk of electric shock.
d) Do not abuse the cord. Never use the cord for
carrying, pulling or unplugging the power tool.
Keep cord away from heat, oil, sharp edges or
moving parts. Damaged or entangled cords increase
the risk of electric shock.
e) When operating a power tool outdoors, use an
extension cord suitable for outdoor use. Use of
a cord suitable for outdoor use reduces the risk of
electric shock.
f) If operating a power tool in a damp location is
unavoidable, use a residual current device (RCD)
a)
24
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
5.1.3 Personal safety
Stay alert, watch what you are doing and use
common sense when operating a power tool. Do
not use a power tool while you are tired or under
the influence of drugs, alcohol or medication. A
moment of inattention while operating power tools
may result in serious personal injury.
b) Use personal protective equipment. Always wear
eye protection. Protective equipment such as dust
mask, non-skid safety shoes, hard hat, or hearing
protection used for appropriate conditions will reduce
personal injuries.
c) Prevent unintentional starting. Ensure the switch
is in the off‐position before connecting to power
source and/or battery pack, picking up or carrying
the tool. Carrying power tools with your finger on the
switch or energising power tools that have the switch
on invites accidents.
d) Remove any adjusting key or wrench before turning the power tool on. A wrench or a key left attached to a rotating part of the power tool may result
in personal injury.
e) Do not overreach. Keep proper footing and balance at all times. This enables better control of the
power tool in unexpected situations.
f) Dress properly. Do not wear loose clothing or
jewellery. Keep your hair, clothing and gloves
away from moving parts. Loose clothes, jewellery
or long hair can be caught in moving parts.
g) If devices are provided for the connection of dust
extraction and collection facilities, ensure these
are connected and properly used. Use of dust
collection can reduce dust-related hazards.
a)
5.1.4 Power tool use and care
Do not force the power tool. Use the correct
power tool for your application. The correct power
tool will do the job better and safer at the rate for
which it was designed.
b) Do not use the power tool if the switch does not
turn it on and off. Any power tool that cannot be
controlled with the switch is dangerous and must be
repaired.
a)
Hilti DEG 125-D/-P, DEG 150-D/-P, Pos.1, Art. Nr.285965/A3, 18.09.2013
Disconnect the plug from the power source
and/or the battery pack from the power tool
before making any adjustments, changing
accessories, or storing power tools. Such
preventive safety measures reduce the risk of
starting the power tool accidentally.
d) Store idle power tools out of the reach of children and do not allow persons unfamiliar with the
power tool or these instructions to operate the
power tool. Power tools are dangerous in the hands
of untrained users.
e) Maintain power tools. Check for misalignment or
binding of moving parts, breakage of parts and
any other condition that may affect the power
tool’s operation. If damaged, have the power tool
repaired before use. Many accidents are caused by
poorly maintained power tools.
f) Keep cutting tools sharp and clean. Properly maintained cutting tools with sharp cutting edges are less
likely to bind and are easier to control.
g) Use the power tool, accessories and tool bits etc.
in accordance with these instructions, taking into
account the working conditions and the work to
be performed. Use of the power tool for operations different from those intended could result in a
hazardous situation.
c)
5.1.5 Service
a)
Have your power tool serviced by a qualified repair
person using only identical replacement parts.
This will ensure that the safety of the power tool is
maintained.
5.2 Safety warnings for abrasive cutting-off
operations
This power tool is intended to function as a cutoff tool. Read all safety warnings, instructions,
illustrations and specifications provided with this
power tool. Failure to follow all instructions listed
below may result in electric shock, fire and/or serious
injury.
b) Operations such as sanding, wire brushing or
polishing are not recommended to be performed
with this power tool Operations for which the power
tool was not designed may create a hazard and cause
personal injury.
c) Do not use accessories which are not specifically
designed and recommended by the tool manufacturer. Just because the accessory can be attached
to your power tool, it does not assure safe operation.
d) The rated speed of the accessory must be at
least equal to the maximum speed marked on the
power tool. Accessories running faster than their
rated speed can break and fly apart.
e) The outside diameter and the thickness of your
accessory must be within the capacity rating of
your power tool. Incorrectly sized accessories cannot be adequately guarded or controlled.
f) Threaded mounting of accessories must match
the grinder spindle thread. For accessories mounted by flanges, the arbour hole of the accessory
g)
h)
i)
j)
a)
k)
l)
m)
n)
o)
p)
must fit the locating diameter of the flange. Accessories that do not match the mounting hardware
of the power tool will run out of balance, vibrate
excessively and may cause loss of control.
Do not use a damaged accessory. Before each
use inspect the accessory such as abrasive
wheels for chips and cracks, backing pad for
cracks, tear or excess wear, wire brush for loose
or cracked wires. If power tool or accessory
is dropped, inspect for damage or install an
undamaged accessory. After inspecting and
installing an accessory, position yourself and
bystanders away from the plane of the rotating
accessory and run the power tool at maximum
no-load speed for one minute. Damaged
accessories will normally break apart during this test
time.
Wear personal protective equipment. Depending
on application, use face shield, safety goggles or
safety glasses. As appropriate, wear dust mask,
hearing protectors, gloves and workshop apron
capable of stopping small abrasive or workpiece
fragments. The eye protection must be capable of
stopping flying debris generated by various operations. The dust mask or respirator must be capable of
filtrating particles generated by your operation. Prolonged exposure to high intensity noise may cause
hearing loss.
Keep bystanders a safe distance away from
work area. Anyone entering the work area must
wear personal protective equipment. Fragments
of workpiece or of a broken accessory may fly
away and cause injury beyond immediate area of
operation.
Hold the power tool by insulated gripping surfaces
only, when performing an operation where the
cutting accessory may contact hidden wiring or
its own cord. Cutting accessory contacting a "live"
wire may make exposed metal parts of the power tool
"live" and could give the operator an electric shock.
Position the cord clear of the spinning accessory.
If you lose control, the cord may be cut or snagged
and your hand or arm may be pulled into the spinning
accessory.
Never lay the power tool down until the accessory has come to a complete stop. The spinning
accessory may grab the surface and pull the power
tool out of your control.
Do not run the power tool while carrying it at your
side. Accidental contact with the spinning accessory
could snag your clothing, pulling the accessory into
your body.
Regularly clean the power tool’s air vents. The
motor’s fan will draw the dust inside the housing
and excessive accumulation of powdered metal may
cause electrical hazards.
Do not operate the power tool near flammable
materials. Sparks could ignite these materials.
Do not use accessories that require liquid
coolants. Using water or other liquid coolants may
result in electrocution or shock.
25
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
en
Hilti DEG 125-D/-P, DEG 150-D/-P, Pos.1, Art. Nr.285965/A3, 18.09.2013
5.3 Kickback and related warnings
en
Kickback is a sudden reaction to a pinched or snagged
rotating wheel, backing pad, brush or any other accessory. Pinching or snagging causes rapid stalling of the
rotating accessory which in turn causes the uncontrolled
power tool to be forced in the direction opposite of the
accessory’s rotation at the point of the binding.
For example, if an abrasive wheel is snagged or pinched
by the workpiece, the edge of the wheel that is entering
into the pinch point can dig into the surface of the material
causing the wheel to climb out or kick out. The wheel may
either jump toward or away from the operator, depending
on direction of the wheel’s movement at the point of
pinching. Abrasive wheels may also break under these
conditions.
Kickback is the result of power tool misuse and/or incorrect operating procedures or conditions and can be
avoided by taking proper precautions as given below.
Maintain a firm grip on the power tool and position your body and arm to allow you to resist
kickback forces. Always use auxiliary handle, if
provided, for maximum control over kickback or
torque reaction during start-up. The operator can
control torque reactions or kickback forces, if proper
precautions are taken.
b) Never place your hand near the rotating accessory. Accessory may kickback over your hand.
c) Do not position your body in the area where power
tool will move if kickback occurs. Kickback will
propel the tool in direction opposite to the wheel’s
movement at the point of snagging.
d) Use special care when working corners, sharp
edges etc. Avoid bouncing and snagging the accessory. Corners, sharp edges or bouncing have a
tendency to snag the rotating accessory and cause
loss of control or kickback.
e) Do not attach a saw chain woodcarving blade or
toothed saw blade. Such blades create frequent
kickback and loss of control.
a)
5.4 Safety warnings specific for grinding and
abrasive cutting-off operations
Use only wheel types that are recommended for
your power tool and the specific guard designed
for the selected wheel. Wheels for which the power
tool was not designed cannot be adequately guarded
and are unsafe.
b) The grinding surface of centre depressed wheels
must be mounted below the plane of the guard lip.
An improperly mounted wheel that projects through
the plane of the guard lip cannot be adequately
protected.
c) The guard must be securely attached to the power
tool and positioned for maximum safety, so the
least amount of wheel is exposed towards the operator. The guard helps to protect operator from
broken wheel fragments, accidental contact with
wheel and sparks that could ignite clothing.
d) Wheels must be used only for recommended applications. For example: do not grind with the side
a)
26
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
e)
f)
of cut-off wheel. Abrasive cut-off wheels are intended for peripheral grinding, side forces applied to
these wheels may cause them to shatter.
Always use undamaged wheel flanges that are of
correct size and shape for your selected wheel.
Proper wheel flanges support the wheel thus reducing the possibility of wheel breakage. Flanges for
cut-off wheels may be different from grinding wheel
flanges.
Do not use worn down wheels from larger power
tools. Wheel intended for larger power tool is not
suitable for the higher speed of a smaller tool and
may burst.
5.5 Additional safety warnings specific for abrasive
cutting-off operations
Do not "jam" the cut-off wheel or apply excessive
pressure. Do not attempt to make an excessive
depth of cut. Overstressing the wheel increases the
loading and susceptibility to twisting or binding of
the wheel in the cut and the possibility of kickback or
wheel breakage.
b) Do not position your body in line with and behind
the rotating wheel. When the wheel, at the point
of operation, is moving away from your body, the
possible kickback may propel the spinning wheel
and the power tool directly at you.
c) When wheel is binding or when interrupting a cut
for any reason, switch off the power tool and hold
the power tool motionless until the wheel comes
to a complete stop. Never attempt to remove the
cut-off wheel from the cut while the wheel is in
motion otherwise kickback may occur.Investigate
and take corrective action to eliminate the cause of
wheel binding.
d) Do not restart the cutting operation in the workpiece. Let the wheel reach full speed and carefully
re-enter the cut. The wheel may bind, walk up or
kickback if the power tool is restarted in the workpiece.
e) Support panels or any oversized workpiece to
minimize the risk of wheel pinching and kickback.
Large workpieces tend to sag under their own weight.
Supports must be placed under the workpiece near
the line of cut and near the edge of the workpiece on
both sides of the wheel.
f) Use extra caution when making a "pocket cut"
into existing walls or other blind areas. The protruding wheel may cut gas or water pipes, electrical
wiring or objects that can cause kickback.
a)
5.6 Additional safety instructions
5.6.1 Personal safety
Always hold the tool securely with both hands on
the grips provided. Keep the grips dry, clean and
free from oil and grease.
b) Breathing protection must be worn if the power
tool is used without a dust extraction system for
work that creates dust.
a)
Hilti DEG 125-D/-P, DEG 150-D/-P, Pos.1, Art. Nr.285965/A3, 18.09.2013
Improve the blood circulation in your fingers by
relaxing your hands and exercising your fingers
during breaks between working.
d) Avoid touching rotating parts. Switch the power
tool on only after bringing it into position at the
workpiece. Touching rotating parts, especially rotating insert tools, may lead to injury.
e) Always lead the supply cord and extension cord
away from the power tool to the rear while working. This helps to avoid tripping over the cord while
working.
f) When grinding with straight grinding discs and
cutting with cutting discs in metalworking applications, use the guard with cover plate.
g) Children must be instructed not to play with the
power tool.
h) The power tool is not intended for use by children,
by debilitated persons or those who have received
no instruction or training.
i) Do not use the power tool if it starts with a jolt.This
may be an indication that the electronic control unit
is defective. Have the tool repaired at an authorized
Hilti service center right away.
j) Dust from material such as paint containing lead,
some wood species, minerals and metal may be
harmful. Contact with or inhalation of the dust may
cause allergic reactions and/or respiratory diseases
to the operator or bystanders. Certain kinds of dust
are classified as carcinogenic such as oak and beech
dust especially in conjunction with additives for wood
conditioning (chromate, wood preservative). Material
containing asbestos must only be treated by specialists. Where the use of a dust extraction device is
possible it shall be used. To achieve a high level
of dust collection, use a suitable vacuum cleaner
of the type recommended by Hilti for wood dust
and/or mineral dust together with this tool. Ensure
that the workplace is well ventilated. The use of a
dust mask of filter class P2 is recommended. Follow national requirements for the materials you
want to work with.
c)
5.6.2 Power tool use and care
Grinding discs must be stored and handled carefully in accordance with the manufacturer’s instructions.
b) Check that the grinding disc is fitted in accordance with the manufacturer's instructions.
c) If use of a spacer ring or other intermediate part is
specified and the part is supplied with the grinding
disc, check to ensure that the part is fitted.
d) Before use, check that the cutting disc has been
fitted correctly and the clamping nut tightened.
Then allow the power tool to run for 60 seconds
under no load while holding it securely. Switch off
the power tool immediately if significant vibration
or any other faults are noticed. Should this occur,
examine the power tool in order to determine the
cause.
e) Never use the power tool without the guard.
a)
Do not use separate reducing rings or adapters to
enable use of grinding discs with a larger mounting hole.
g) If the grinding disc (or cup wheel, etc.) is equipped
with a threaded insert, check that the threaded
section is long enough to take up the length of
the drive spindle.
h) The workpiece must be fixed securely in place.
i) Do not use cutting discs for grinding.
j) Take steps to ensure that flying sparks from the
tool do not present a hazard, i.e. by striking yourself or other persons or by igniting inflammable
substances. Adjust the position of the disc guard
accordingly.
k) When working in dusty conditions, check to ensure that the cooling air openings remain unobstructed. Should it become necessary to remove
dust deposits from the air openings, first unplug
the tool from the electric supply and then use a
non-metallic object to remove the dust, taking
care to avoid damaging parts inside the tool.
l) The disc continues to rotate after the power tool
has been switched off. Wait until the disc stops
rotating.
f)
5.6.3 Electrical safety
Before beginning work, check the working area
(e.g. using a metal detector) to ensure that no
concealed electric cables or gas and water pipes
are present. External metal parts of the power tool
may become live, for example, when an electric cable
is damaged accidentally. This presents a serious risk
of electric shock.
b) Check the power tool’s supply cord at regular
intervals and have it replaced by a qualified specialist if found to be damaged. If the power tool’s
supply cord is damaged it must be replaced with
a specially-prepared supply cord available from
Hilti Customer Service. Check extension cords
at regular intervals and replace them if found to
be damaged. Do not touch the supply cord or
extension cord if it is damaged while working.
Disconnect the supply cord plug from the power
outlet. Damaged supply cords or extension cords
present a risk of electric shock.
c) Dirty or dusty power tools which have been used
frequently for work on conductive materials
should be checked at regular intervals at a Hilti
Service Center. Under unfavorable circumstances,
dampness or dust adhering to the surface of
the power tool, especially dust from conductive
materials, may present a risk of electric shock.
d) When working outdoors with an electric tool
check to ensure that the tool is connected to the
electric supply by way of a ground fault circuit
a)
27
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
en
Hilti DEG 125-D/-P, DEG 150-D/-P, Pos.1, Art. Nr.285965/A3, 18.09.2013
e)
en
interrupter (RCD) with a rating of max. 30 mA
(tripping current). Use of a ground fault circuit
interrupter reduces the risk of electric shock.
Use of a ground fault circuit interrupter (RCD
residual current device) with a maximum tripping
current of 30 mA is recommended.
5.6.5 Personal protective equipment
5.6.4 Work area
a) Ensure that the workplace is well lit.
b) Ensure that the workplace is well ventilated. Exposure to dust at a poorly ventilated workplace may
result in damage to the health.
The user and any other persons in the vicinity must
wear suitable eye protection, a hard hat, ear protection, protective gloves and breathing protection while
the power tool is in use.
6 Before use
6.2.1 Fitting the guard or guard with cover plate 8
DANGER
Disconnect the plug from the power source before
making any adjustments, changing accessories, or
storing the tool. Such preventive safety measures
reduce the risk of starting the tool accidentally.
CAUTION
Wear gloves when fitting or removing parts, when
making adjustments or when remedying malfunctions.
WARNING
Never use the power tool without the guard.
CAUTION
Before using another accessory that is recommended for the angle grinder in conjunction with the
angle grinders mentioned above, read the operating instructions for the applicable angle grinder and
observe all instructions.
6.1 Fitting the side handle
NOTE
The keyed locating lug on the guard ensures that only
a guard designed for use with the power tool can be
fitted. The keyed locating lug also prevents the guard
from coming into contact with the disc.
1.
2.
6.2.2 Adjusting the guard 6
1.
2.
The side handle may be screwed onto the tool on the
right or left.
2.
CAUTION
The closed side of the guard must always face the
operator.
28
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
Press the guard release button and then rotate the
guard until the triangular marks on the guard and
the power tool are in alignment.
Lift off the guard.
6.2.4 Fitting and removing the front cover 9
1.
6.2 Guard
Press the guard release button and then rotate the
guard until it engages in the desired position.
6.2.3 Removing the guard or guard with cover plate
1.
WARNING
The side handle must be fitted for all types of work.
CAUTION
Adjust the position of the guard to suit the requirements of the work being done.
Fit the guard onto the drive spindle collar so that the
two triangular marks on the guard and on the power
tool in alignment.
Press the guard onto the drive spindle collar; press
the guard release button and then rotate the guard
until it engages and the guard release button jumps
back to its outset position.
Press the front cover onto the standard guard, with
the closed side positioned as shown in the illustration, until it engages.
To remove the front cover, release the catch and
then pull the front cover away from the standard
guard.
6.3 Fitting and removing the disc 10 11
DANGER
Check that the speed rating printed on the grinding
disc is equal to or higher than the rated speed of the
tool.
Hilti DEG 125-D/-P, DEG 150-D/-P, Pos.1, Art. Nr.285965/A3, 18.09.2013
DANGER
Check the condition of the grinding disc before using it. Do not use discs that are broken, cracked or
damaged in any way.
NOTE
Diamond discs must be replaced when the cutting or
grinding performance drops significantly. This generally
is the case when the segments reach a height of less
than 2 mm. Other discs must be replaced when the
cutting performance drops significantly or other parts of
the angle grinder (not the disc) come into contact with
the material you are working on. Abrasive discs generally
have to be replaced when the durability date has been
reached.
1.
2.
3.
4.
5.
6.
CAUTION The clamping flange is equipped with an
O-ring. The O-ring must be replaced if missing or
damaged.
Fit the clamping flange onto the drive spindle.
Fit the disc.
Screw on the clamping nut corresponding to the
type of disc fitted 11.
CAUTION Do not press the spindle lockbutton
before the drive spindle has stopped rotating.
Press the spindle lockbutton and hold it in this
position.
Use the wrench to tighten the clamping nut securely
and then release the spindle lockbutton.
To remove the disc from the power tool, follow the
instructions for fitting the disc but carry out the steps
in the reverse order.
6.4 Insert tool with Kwik-Lock quick-release nut
CAUTION
When operating the power tool, take care to ensure
that the Kwik-Lock nut does not come into contact
with the work surface. Do not use a damaged KwikLock nut.
NOTE
The Kwik-Lock nut may be used instead of the standard
clamping nut. No tools are then required for changing
cutting discs.
6.4.1 Fitting and removing the insert tool using the
Kwik-Lock quick-release nut 12
NOTE
The arrow on the upper surface of the nut must be within
the index marks. If the arrow is not within the index marks
when the nut is tightened, it will be impossible to release
the nut by hand. In this case, use the pin wrench to
release the Kwik-Lock nut (do not use a pipe wrench!).
1.
2.
3.
4.
5.
6.
7.
Clean the clamping flange and the quick release
clamping nut.
CAUTION The clamping flange is equipped with an
O-ring. The O-ring must be replaced if missing or
damaged.
Fit the clamping flange onto the drive spindle.
Fit the insert tool.
Screw the Kwik-Lock nut onto the spindle until it
contacts the insert tool (the side with the lettering
should be visible after the nut is screwed on).
CAUTION Do not press the spindle lockbutton
before the drive spindle has stopped rotating.
Press the spindle lockbutton and hold it in this
position.
Use the wrench to tighten the clamping nut or,
respectively, rotate the insert tool firmly by hand in a
clockwise direction until the Kwik‑Lock nut is tight,
and then release the spindle lockbutton.
To remove this, follow the instructions for fitting the
module but carry out the steps in the reverse order.
6.5 Rotating the gearing section 13
NOTE
To allow the tool to be used safely and without fatigue
in all positions (e.g. on / off switch facing upwards), the
gearing section can be rotated to one of four positions at
90° intervals.
1.
2.
3.
4.
5.
6.
Clean the tool.
Remove the side handle from the tool.
Remove the four screws from the gearing section.
Rotate the gearing section to the desired position
without pulling it away from the tool.
Secure the gearing section by inserting and tightening the four screws.
Fit the side handle.
7 Operation
CAUTION
The closed side of the guard must always face the
operator.
NOTE
Adjust the position of the guard to suit the requirements
of the work being done.
WARNING
Test new cutting or grinding discs by allowing them
to run at maximum speed in a protected area for at
least 30 seconds.
DANGER
Wear ear protectors. Exposure to noise can cause hearing loss.
WARNING
Do not use the power tool if it starts with a jolt.This
may be an indication that the electronic control unit is
29
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
en
Hilti DEG 125-D/-P, DEG 150-D/-P, Pos.1, Art. Nr.285965/A3, 18.09.2013
defective. Have the tool repaired at an authorized Hilti
service center right away.
en
WARNING
Slits cut in loadbearing walls of buildings or other structures may influence the statics of the structure, especially
when steel reinforcing bars or load-bearing components
are cut through. Consult the structural engineer, architect, or person in charge of the building project
before beginning the work.
WARNING
The electric supply voltage must comply with the information given on the type identification plate on the
power tool. 230 V power tools may also be connected
to a 220 V supply.
WARNING
Always use the side handle with the power tool (use
the hoop handle as an option).
WARNING
Use clamps or a vice to hold the workpiece securely.
WARNING
Breathing protection must be worn if the power tool
is used without a dust extraction system for work that
creates dust.
WARNING
Avoid touching rotating parts. Switch the power tool
on only after bringing it into position at the workpiece.
Touching rotating parts, especially rotating insert tools,
may lead to injury.
CAUTION
The insert tool may get hot during use. Wear protective
gloves when changing insert tools.
CAUTION
In accordance with the applications for which it is designed, the power tool produces a high torque. Always
use the side handle and hold the power tool with both
hands. The user must be prepared for sudden sticking
and stalling of the insert tool.
CAUTION
Working on the material may cause it to splinter. Wear
eye protection and protective gloves. Wear breathing
protection if no dust removal system is used. Splintering material presents a risk of injury to the eyes and
body.
WARNING
Reduce the load on the power tool by avoiding tilting
the disc in the kerf when cutting. The disc or wheel
may otherwise break, or the power tool may kick back or
stall.
30
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
CAUTION
Improve the blood circulation in your fingers by relaxing your hands and exercising your fingers during
breaks between working.
WARNING
Keep inflammable materials away from the working
area.
7.1 Rough grinding
CAUTION
Never use abrasive cutting discs for grinding.
Best results are obtained when the disc maintains an
angle of 5° to 30° with the working surface when grinding.
Move the power tool to and fro while applying moderate
pressure. This will avoid overheating and discoloration of
the workpiece and ensure an even surface finish.
7.2 Cutting
When cutting, apply moderate feed pressure and do not
tilt the power tool or, respectively, the cutting disc (hold
at approx. 90° to the surface being cut). For best results,
start cutting at the smallest cross section when cutting
profiles and square tube.
7.3 Switching on / off without locking the switch
(DEG 125-D or DEG 150-D)
7.3.1 Switching on
1.
2.
Plug the supply cord into the power outlet.
Slide the on / off switch forward and then press it as
far as it will go.
7.3.2 Switching off
Release the on / off switch.
7.4 Switching on / off (tools with switch lock: DEG
125-D or DEG 150-D)
NOTE
If the tool is unplugged from the electric supply while
the on / off switch is locked in the on position and
subsequently plugged back into the electric supply, the
tool will not restart. The switch lock must be released
while the tool is disconnected from the electric supply
before the supply cord is again plugged into the power
outlet.
7.4.1 Switching on and locking the switch
1.
2.
Plug the supply cord into the power outlet.
Slide the on / off switch forward slightly (3 mm) and,
while pressing it down, slide it further forward until
it locks in position.
Hilti DEG 125-D/-P, DEG 150-D/-P, Pos.1, Art. Nr.285965/A3, 18.09.2013
7.4.2 Switching off after locking the switch
Press the front part of the on / off switch down (the lock
then releases).
7.5 Restart interlock
NOTE
If the power tool is unplugged from the electric supply
while the on / off switch is locked in the on-position and
subsequently plugged back into the electric supply, it
will not restart. The switch lock must be released while
the power tool is disconnected from the electric supply
before the supply cord is again plugged into the power
outlet.
8 Care and maintenance
CAUTION
Disconnect the mains plug from the power outlet.
8.1 Care of the power tool
DANGER
Under extreme conditions, when used for working on
metal, conductive dust may accumulate inside the tool.
This may have an adverse effect on the tool’s protective
insulation. Under such conditions, the tool should be
plugged into a ground fault circuit interrupter (RCD)
and use of a stationary dust removal system and
frequent cleaning of the tool’s cooling air slots is
recommended.
The outer casing of the power tool is made from impactresistant plastic. Sections of the grip are made from a
synthetic rubber material.
Never operate the power tool when the air vents are
blocked. Regularly clean the power tool’s air vents carefully with a dry brush. Do not permit foreign objects to
enter the interior of the tool. The motor’s fan will draw
dust into the casing and an excessive accumulation of
conductive dust (e.g. metal, carbon fiber) may cause
electrical hazards. Clean the outside of the power tool at
regular intervals with a slightly damp cloth. Do not use
a spray, steam pressure cleaning equipment or running
water for cleaning. This may negatively affect the electrical safety of the tool. Always keep the grip surfaces
of the tool free from oil and grease. Do not use cleaning
agents which contain silicone.
NOTE
Frequent work on conductive materials (e.g. metal, carbon fiber) may make shorter maintenance intervals necessary. Take your individual work place risk assessment
into account.
8.2 Maintenance
WARNING
Do not operate the tool if parts are damaged or
when the controls do not function faultlessly. Have
the power tool repaired by Hilti Service.
WARNING
Repairs to the electrical section of the power tool may
be carried out only by trained electrical specialists.
Check all external parts of the power tool for damage
at regular intervals and check that all controls operate
faultlessly.
8.3 Checking the power tool after care and
maintenance
After carrying out care and maintenance work on the
power tool, check that all protective and safety devices
are fitted and that they function faultlessly.
9 Troubleshooting
Fault
Possible cause
Remedy
The power tool doesn’t start.
Interruption in the electric supply.
Plug in another electric appliance and
check whether it works.
Have the supply cord and plug
checked by an electrical specialist
and replaced if necessary.
Use an extension cord with an adequate conductor cross section.
Supply cord or plug defective.
The power tool doesn’t achieve
full power.
The extension cord’s conductor cross
section is inadequate.
31
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
en
Hilti DEG 125-D/-P, DEG 150-D/-P, Pos.1, Art. Nr.285965/A3, 18.09.2013
10 Disposal
en
Most of the materials from which Hilti power tools or appliances are manufactured can be recycled. The materials
must be correctly separated before they can be recycled. In many countries, Hilti has already made arrangements for
taking back your old power tools or appliances for recycling. Please ask your Hilti customer service department or
Hilti representative for further information.
For EC countries only
Disposal of electric tools together with household waste is not permissible.
In observance of the European Directive on waste electrical and electronic equipment and its implementation in accordance with national law, electrical appliances that have reached the end of their life
must be collected separately and returned to an environmentally compatible recycling facility.
11 Manufacturer’s warranty - tools
Hilti warrants that the tool supplied is free of defects in
material and workmanship. This warranty is valid so long
as the tool is operated and handled correctly, cleaned
and serviced properly and in accordance with the Hilti
Operating Instructions, and the technical system is maintained. This means that only original Hilti consumables,
components and spare parts may be used in the tool.
This warranty provides the free-of-charge repair or replacement of defective parts only over the entire lifespan
of the tool. Parts requiring repair or replacement as a
result of normal wear and tear are not covered by this
warranty.
32
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
Additional claims are excluded, unless stringent national rules prohibit such exclusion. In particular, Hilti
is not obligated for direct, indirect, incidental or consequential damages, losses or expenses in connection with, or by reason of, the use of, or inability to
use the tool for any purpose. Implied warranties of
merchantability or fitness for a particular purpose are
specifically excluded.
For repair or replacement, send the tool or related parts
immediately upon discovery of the defect to the address
of the local Hilti marketing organization provided.
This constitutes Hilti’s entire obligation with regard to
warranty and supersedes all prior or contemporaneous
comments and oral or written agreements concerning
warranties.
Hilti DEG 125-D/-P, DEG 150-D/-P, Pos.1, Art. Nr.285965/A3, 18.09.2013
12 EC declaration of conformity (original)
Designation:
Type:
Year of design:
angle grinder
DEG 125‑D / DEG 125‑P,
DEG 150‑D / DEG 150‑P
2005
We declare, on our sole responsibility, that this product
complies with the following directives and standards:
2006/42/EC, 2004/108/EC, 2011/65/EU, EN 60745‑1,
EN 60745‑2‑3, EN ISO 12100.
Technical documentation filed at:
Hilti Entwicklungsgesellschaft mbH
Zulassung Elektrowerkzeuge
Hiltistrasse 6
86916 Kaufering
Deutschland
en
Hilti Corporation, Feldkircherstrasse 100,
FL‑9494 Schaan
Paolo Luccini
Head of BA Quality and Process Management
Business Area Electric Tools & Accessories
01/2012
Jan Doongaji
Executive Vice President
Business Unit Power
Tools & Accessories
01/2012
33
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
Hilti Corporation
Hilti = registered trademark of Hilti Corp., Schaan
W 3089 | 1013 | 10-Pos. 1 | 1
Printed in Germany © 2013
Right of technical and programme changes reserved S. E. & O.
Printed: 21.11.2013 | Doc-Nr: PUB / 5162495 / 000 / 00
285965 / A3
285965
160992A0GZ
*285965*
LI-9494 Schaan
Tel.: +423 / 234 21 11
Fax:+423 / 234 29 65
www.hilti.com

advertisement

Key Features

  • Constant-speed electronics
  • ATC (Active Torque Control)
  • Restart interlock
  • Temperature-dependent motor protection
  • Electronic starting current limiter

Frequently Answers and Questions

What are the recommended minimum conductor cross sections and maximum cable lengths for extension cords used with this tool?
The recommended minimum conductor cross sections and maximum cable lengths are provided in the Operating Instructions document.
Can I use this tool to work on materials hazardous to health, such as asbestos?
No, working on materials hazardous to health is not permissible with this tool.
Can I use the DG-EX 125/5" dust removal hood to work on metal?
No, this guard is only for grinding mineral materials. Using it on metal is prohibited.
What is the maximum diameter of the disc that can be used with this tool?
The maximum disc diameter is 125 mm for the DEG 125-D/-P and 150 mm for the DEG 150-D/-P.
Can I use the power tool without the guard?
No, never use the power tool without the guard. This is a safety precaution and is essential for protecting the user from potential hazards.

Related manuals

Download PDF

advertisement