PURPOSE OF STAUS LIGHT
A visual warning system should be installed if a condition can
exist on an installation which may be hazardous for the helicopter
or its occupants. The system (Status Lights) should be a
flashing red light (or lights), visible to the pilot from any direction
of approach and on any landing heading. The aeronautical
meaning of a flashing red light is either “do not land, aerodrome
not available for landing” or “move clear of landing area”.
The system should be automatically initiated at the appropriate
hazard level (e.g. impending gas release) as well as being
capable of manual activation by the HLO.
COMPLIANCE STANDARDS
Tranberg Status Light System complies with the following
offshore standards:
• CAA UK CAP437:2013
• NORMAM-27/DPC:2015
• 2009 MODU Code:2010
NUMBER AND LOCATION OF LIGHT UNITS
TEF 9980 SYSTEM FEATURES
The number and location of light units should be considered in
cooperation with the helideck operator. Ref. CAA Paper 2008/01,
section 4.8 and 6.2 for further guidance.
• ATEX and IECEx certified for use in Zone 1, Zone 2 and safe
area.
• The helideck status light signalling system shall be installed either on or adjacent to the helideck.
• Height of light units <25cm. Allows for on-deck installation.
• The status light shall be visible from all approach angles, i.e.
360° in azimuth. In case of obstacles blocking visibility, additional lights may be added at other locations.
• Automatic monitoring of all light units. No need for redundancy.
• Maintenance free.
• Constructed with durable, high quality materials.
• Wide ambient temperature range; -40°C to +55°C.
• Control panel is delivered for connection to 18-32VDC and
100-240V 50/60Hz power supply.
• Low power consumption: Main light, 30W & Repeater light 2,6W.
• Wide input voltage range, 16-32V. Allows for longer cable
stretch with smaller cross section than any competitors.
• While the helicopter is landed on the helideck, intensity shall be
dimmed to maximum 60cd. At least one light shall be visible to
the pilot when the helicopter is on the helideck, regardless of its
orientation to the deck. Note: Output light characteristics are
the same for repeater light and main light when in “dim” mode.
Note: The light units when in combination with Tranberg control
system are automatically monitored. Of this reason, according to
CAA Paper 2008/01, redundancy light units and components can
be omitted.
• Flexible wiring methods.
• Prepared for remote control and monitoring.
• NVG (Night Vision Goggle) compatible
Subject to change without prior notice
Tranberg AS | P.O. Box 8033 | N-4068 Stavanger | Norway | Tel.: (47)51 57 89 00 | Fax.: (47)51 57 89 50
E-mail: [email protected] | www.tranberg.com
Tranberg Systems | Hjulmagervej 15C | 7100 Vejle | Denmark | Tel.: (45) 75 85 83 80
E-mail: [email protected] | www.tranbergsystems.com
TTP5709
TEF 9980 STATUS LIGHT SYSTEM
PROPOSED LOCATION OF LIGHT UNITS
M = Main light
SYSTEM WIRING
• The control cabinet is delivered with connections for up to two
main lights and two repeater lights as standard.
R = Repeater
light
• One main light, plus one or two repeater lights can be connected
to same output. This can in many cases save cabling.
M
6+PE
• Power and signals can be wired in a single multi cable orOption:
split up
in two cables, one for power and one for signals. Allows Remote
for using
large cross section for power wires and smaller cross section for
signals.
• The light units are delivered with flying lead
cable shall be terminated in an Ex approved
7+PE
JB
PE
M
6+PE
7+PE
JB
Power Supply
cable. This open2+PE
end Control
junction box.
system
PE
R
6+PE
• The Status Light System should be fed from an uninterrupted power supply (UPS) system.
7+PE
JB
PE
R
6+PE
7+PE
JB
EXAMPLES - SYSTEM WIRING
PE
M
6+PE
Option:
Remote
JB
M
7+PE
PE
Option:
Remote
PE
Power Supply
2+PE
8+PE
6+PE
JB
7+PE
7+PE
Control
system
R
6+PE
JB
7+PE
Control
system
PE
JB
JB
PE
7+PE
PE
EXAMPLES - WIRING
8+PE
Option:
Remote
M
JB
R
7+PE
PE
JB
systemsystem
6+PE
JB
7+PEPE
M
JB
7+PE
PE
PE
MAIN OR
REPEATER LIGHT
6+PE
Control
system
7+PE
R
7+PE
JB
MAIN OR
REPEATER
LIGHT
7+PE
Power Supply
ControlControl
6+PE
2+PE
2+PE (Pwr)
4+PE (Signal)
JB
7+PE
PE
PE
MAIN LIGHT
Control
system
REPEATER LIGHT
2+PE (Pwr)
5+PE (Signal)
JB
7+PE
7+PE
JB
PE
7+PE
PE
6+PE
R
7+PE
JB
PE
6+PE
M
6+PE
R
6+PE
JB
PE
M
Power Supply
2+PE
R
7+PE
JB
7+PE
PE
TEF 9980 STATUS LIGHT SYSTEM
CABLE DIMENSIONS
Voltage drop in cables should be calculated to ensure that voltage at lamp is minimum 16V. Use a current consumption of 6.15A for main lamp and
0.41A for repeater light to calculate voltage drop.
Note:
• The control cabinet incorporates a regulated power supply, and voltage out from cabinet can be considered to be 24VDC. Voltage drop in power
supply cable will be compensated in regulator.
• Voltage drop in the 3 meters flying lead cable from lamp can be omitted from calculations.
• If necessary the voltage at control cabinet can be adjusted up to 28.5V.
Recommendation
One Main Light, Power Lines Wire 1 and 2 (Voltage at control cabinet = 24V)
Dimension
Cable Length
<60 meter
2,5mm2
<100 meter
4mm2
<140 meter
6mm2
<230 meter
10mm2
Repeater light and signal lines: Recommendation: Min. 1.5mm2 regardless of cable length (<300m).
ORDERING INFORMATION
1
Determine No. and type of light units.
2
Select No. and type of junction box
3
4
Select type of control panel.
Options
Description
Part No.
TEF9980 Main Light
9980 000
TEF9980 Repeater Light
9980 005
TEF1058 for single lamp connection
1058 2089
TEF1058 for single lamp connection + cable
termination to next lamp
1058 2589
TEF9980 Ex outdoor 100-240VAC
9980 010
TEF9980 Ex outdoor 18-32VDC
9980 012
TEF9980 non-Ex indoor 100-240VAC
9980 020
TEF9980 non-Ex indoor 18-32VDC
9980 022
TEF9980 non-Ex outdoor 100-240VAC
9980 030
TEF9980 non-Ex outdoor 18-32VDC
9980 032
Ex Remote Panel, full control and monitoring
9980 040
Ex Remote Panel, “dim” signal only
9980 041
Eye bolt for fixing of security wire
Note 1:
The light units are delivered with flying lead cable. This open end cable
shall be terminated in an Ex approved junction box.
Note 2:
Tranberg also delivers integrated control systems for controlling
other helideck lights in addition to status lights. Contact Tranberg for
information.
Tranberg AS | P.O. Box 8033 | N-4068 Stavanger | Norway | Tel.: (47)51 57 89 00 | Fax.: (47)51 57 89 50
E-mail: [email protected] | www.tranberg.com
Tranberg Systems | Hjulmagervej 15C | 7100 Vejle | Denmark | Tel.: (45) 75 85 83 80
E-mail: [email protected] | www.tranbergsystems.com
0000 5838
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement