Panasonic FX-301 Series Digital Fiber Sensors

Panasonic FX-301 Series Digital Fiber Sensors
Digital Fiber Sensor
PNP output
type available
Timer
Light intensity Interference Automatic sensitivity
prevention setting
monitor
Fiber
Selection
FIBER SENSORS
FX-301 SERIES
FX-302
Digital Setting
FX-301
Superior performance and
advanced user-friendly
multi-functionality
enables expert usage on
the very first day
* Passed the UL 991 Environment Test
FZ-10
FX-11A
FX-CH
FX-311
Color Detection Analog Output Manually Set Bank Selection Unit
FX-303
http://www.fiber-sensor.com
* UL 61010C-1 compatible, Passed the UL 991 Environment Test based on SEMI S2-0200.
[Category applicable for semiconductor manufacturing: TWW2, Process Equipment]
[Applicable standards: UL 61010C-1]
[Additional test / evaluation standards as per intended use: UL 991, SEMI S2-0200]
Conforming to
EMC Directive
UL Recognition
Long-range sensing made possible with built-in optical lens
Stable long-term sensing
Enhanced worksite-friendly installability
For the first time in the industry, an
optical ‘double coupling lens’ has been
incorporated directly into the fiber
sensor itself. This lens maximizes the
light emission efficiency, resulting in a
tremendous improvement in the
sensing range. Sensing ranges with
small diameter fibers and ultra-small
diameter fibers, which have become
very popular in recent years due to the
miniaturization of chip components,
have been increased by 50 % over
previous values achieved with other
amplifiers.
The newly developed four-chemical
emitting element that uses the FX-301
(red LED type) suppresses changes
over long periods of time as much as
possible, so that a stable light emitting
level is maintained. There is very little
element deterioration so that stable
and accurate sensing can be
maintained over long periods.
Our new fiber cutter utilizes a specially
developed two-in-one fiber attachment
that now makes it possible to cut two
fibers simultaneously to exactly the
same length. Also, since the fibers can
be attached to the amplifier while
being fixed in position in the two-in-one
fiber attachment, sensitivity changes
due to variation in the amount of fiber
insertion do not occur.
FX-301 series
(Double coupling lens)
Selectable response time
Fiber cutter
We offer 4 selectable levels to
correspond with various applications:
the response time 150 !s FAST mode,
the LONG mode, perfect for adverse
environments, and the S-D mode,
especially made for minute detection.
Selectable sensing range as per the application
Ex.: the FX-301 fiber sensor
and the FT-B8 fiber
Emitting
element
LONG
Fiber
Double coupling lens
The lens concentrates the light, greatly
increasing emitting efficiency.
Conventional fiber sensors
(No lens)
STD
1,100 mm 43.307 in
Long range mode (LONG): Response time 2 ms
530 mm 20.866 in
Standard mode (STD): Response time 250 !s
FAST
400 mm 15.748 in
High-speed mode (FAST): Response time 150 !s
S-D
180 mm 7.087 in
Reduced light intensity mode (S-D): Response time 250 !s
Two-in-one fiber
attachment
Cut 2 equal
length fibers
simultaneously
mThe S-D mode can be set in the red LED type only.
Disperses the light reduces
emitting efficiency.
62 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Both main and sub units utilize the same
amplifier body. This feature allows for
easy mounting in the side-by-side
configuration. The main and sub unit
functions are distinguished only by the
proper use of 3-core main cable and the
1-core sub cable. Moreover, by utilizing
the same body for both main and sub
units, inventory management and
maintenance is simplified.
Up to sixteen amplifiers can be
connected in a side-by-side configuration.
As the sub cable contains only one output
line, a great amount of wiring and space
can be saved. Also, special ‘sliding’
connectors have been provided for all
main and sub cables, which can be
detached merely by releasing the lock
and pulling directly back, without having
to slide the amplifier body to the side.
Using this connector system, only a
minimal amount of space is required for
regular maintenance.
With regard to effects on the environment,
we only utilize the simplest of packaging
methods greatly contributing to the reduction
in wastes generated by your worksite.
Also, the bags are made of polyethylene, a
substance that doesn’t give off polluting
gases when burned.
Sliding connectors
are easy to insert
and remove
Sub cable
CN-71-C
Digital Setting
FX-302
Identical part numbers
eliminate the need for costly
inventory management labor
Environmentally friendly packaging
FIBER SENSORS
Wiring- and labor-saving design allows sideby-side configuration for up to sixteen units
FX-301
Easy maintenance, as main
and sub units are identical
Fiber
Selection
FX-301
Polyethylene packaging
Even beginners can quickly learn how to use the MODE NAVI
MODE NAVI uses six indicators to display the amplifier’s basic operations. The current operating mode can be confirmed at a
glance, so even a first time user can easily operate the amplifier without becoming confused.
RUN
TEACH
This is the sensing mode.
Incident light level is displayed in the
digital display.
ADJ
This mode is for setting the threshold
value.
PUSH
In this mode, the threshold value, once
set, may be fine-tuned.
PUSH
PUSH
PUSH
PRO
TIMER
This mode allows the selection of
further advanced functions, such as
the copying of individual settings
and the memory functions.
L/D ON
This mode allows the selection of
output operation as either Light-ON
or Dark-ON.
This mode permits the choice of using
or not using the timer.
PUSH
PUSH
The use of only two switches makes for very simple operations
Only two switches, the large jog switch and the large MODE key, are required for
operation. Depressing the large MODE key sets the ‘mode selection’ and ‘mode
cancel’ functions. The large jog switch is used to select from the detailed functions
available within each mode, as well as to change numerical values after the mode
has been chosen.
Large jog switch
Large MODE key
1
2
Pressing the switch selects or
cancels the operating mode
3
Moving the switch from side
to side allows items to be
selected
Pressing the switch then
confirms the selected
setting
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected] 63
Color Detection Analog Output Manually Set Bank Selection Unit
FX-311
FX-11A
FX-CH
FZ-10
FX-303
Main cable
CN-73-C
FIBER SENSORS
4 types of light sources available
In addition to our red LED (four-chemical
emitting element) type, the blue, green,
and infrared LED types are also provided
to correspond to your specific application.
Optical communication function lets
multiple sensors be adjusted all at once
The optical communication function
allows the data that is currently set to
be copied and saved all at once for all
amplifiers connected together from the
right side. This greatly reduces
troublesome setup tasks and makes
setup much smoother.
Single copy & save operation for all amplifiers
FX-301
Fiber
Selection
FX-301
These sensors are equipped with 3
types of timers, ON-delay, OFF-delay,
and ONE SHOT, for compatibility to
variegated environments.
ON-delay timer
This function is useful for sensing only
objects taking a long time travel.
OFF-delay timer
This function is useful when the
connected device has a slow response
time.
ONE SHOT timer
This function is useful when the input
specifications of the connected device
require a signal of fixed width.
Sensing condition
FX-302
Digital Setting
FX-303
FZ-10
FX-11A
FX-CH
FX-311
Color Detection Analog Output Manually Set Bank Selection Unit
Equipped with each type of timer
T1
ON-delay
T1
OFF-delay
ONE SHOT
T1
T1
T1
T1
T1 : Timer period
Easy code input setting
Every function can be directly set merely by the input of a four digit code (numbers) from the code table. This convenient
feature is easy to set up.
In the event that settings are accidentally changed at the operating site, merely entering the correct code can restore the
original settings. This results in easy and quick maintenance.
First digit:
Settings for response time
and hysteresis
Second digit:
Settings for L/D ON and
display mode
[Code setting table]
First digit
Second digit
Third digit
Direct
code Response time Hysteresis L/D ON Display mode Adjust lock Timer
H-02 (standard) L-ON
ON
OFF
STD
digit
Fourth digit: Timer settings
Third digit:
Settings for Adjust lock and timer
Fourth digit
Timer setting
OFF
STD
H-03 (large)
L-ON
%
ON
OFF-delay
1 ms
STD
H-01 (small)
L-ON
Peak hold
ON
ON-delay
3 ms
LONG
H-02 (standard)
L-ON
Bottom hold
ON
ONE SHOT
5 ms
LONG
H-03 (large)
D-ON
digit
OFF
OFF
10 ms
LONG
H-01 (small)
D-ON
%
OFF
OFF-delay
30 ms
FAST
H-02 (standard)
D-ON
Peak hold
OFF
ON-delay
50 ms
FAST
H-03 (large)
D-ON
Bottom hold
OFF
ONE SHOT
100 ms
FAST
H-01 (small)
S-D
300 ms
H-02 (standard)
500 ms
represents a description of the setting in the picture on the left.
Invertible digital display
Selectable cable length
The digital display can be inverted as per its orientation once mounted onto the amplifier.
Made available are 3 lengths, 1 m 3.281 ft,
2 m 6.562 ft, and 5 m 16.404 ft, to suit
your application requirements. This helps
reduce the waste caused by cutting cables
and lightens the installation workload.
Conventional model
FX-301 SERIES
Used for intermediate terminal block
To PLC
‘turn OFF’ status
Directly connected to the PLC
To PLC
5m 16.404 ft cable length type
5 m 16.404 ft
‘turn ON’ status
2 m 6.562 ft
1 m 3.281 ft
64 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Optional units for greater freedom and control when installing
Sensor-PLC connection system
SC SERIES
Without directly manipulating the
sensor itself, you can simultaneously
switch up to 16 fiber sensors’ settings
using an external emitted signal.
(Load and save)
mAlso possible with the FX-301 series’ databank
function
(Refer to p.144 l for details)
Inductive proximity
sensor
Morning Lot
All settings are changed in a single step
Signal for changing the settings
Photoelectric
sensor
PLC
Afternoon Lot
FX-301
(Refer to p.876 l for details)
Custom circuit board
FX-CH SERIES
Fiber
Selection
This wire-saving system enables the
collective connection of up to 16 I/O
devices with an MIL connector.
Scattered installation is also possible
with the help of a sensor separate
unit.
Bank selection unit
FIBER SENSORS
FX-301
Cylinder switch Micro photoelectric sensor
FX-CH
8-channel connector
input extension unit
1-channel connector
input extension unit
Main unit
Simultaneous
settings changes
Channel 1
OK
Channel 2
NG
OK
No cap present
NG
No cap present
APPLICATIONS
Workpieces detection
Sensing semi-transparent stickers
Sensing register marks
This standard type of FX-301 using red light
has a four-chemical emitting element for
stable sensing over long periods.
The blue LED type greatly reduces the
dampening rate, making it ideal for delicate
sensing.
The green LED type can accurately
discriminate between red and yellow, that
cannot be easily detected using red LED
type.
Yellow
FX-301B
FX-301G
Red
Sensing film meandering
Detecting chip component
Infrared LED type is ideal for sensing
environments with light restrictions, such as
places where light-sensitive film is being
handled. (The emission peak wavelength:
940 nm 0.037 mil.) It includes full-auto
teaching function which allows sensitivity to
be set without stopping the workpiece line.
Because of low light intensity fluctuations
when detecting minute moving objects,
decrease the hysteresis in PRO mode and
accurate sensing will be possible in highspeed mode. This method is optimal for chip
component verification in taping equipment.
Detecting register marks on a
transparent sheet
When detecting registration marks on
transparent film with a thru-beam type, the
S-D (reduced light intensity) mode will
enable minute light intensity fluctuation
sensing.
FX-301H
FT-FM2
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected] 65
Color Detection Analog Output Manually Set Bank Selection Unit
FX-311
FX-11A
FX-CH
FZ-10
FX-303
Separate unit
Digital Setting
FX-302
Simultaneous settings changes
FIBER SENSORS
FX-301
ORDER GUIDE
Amplifiers Quick-connection cable is not supplied with the amplifier. Please order it separately.
Appearance
FX-302
Digital Setting
PNP output
FX-301
Digital
NPN output
Fiber
Selection
Type
Quick-connection cables
Type
FX-303
FZ-10
FX-11A
FX-CH
FX-311
Color Detection Analog Output Manually Set Bank Selection Unit
Emitting element
FX-301
Red LED
FX-301B
Blue LED
FX-301G
Green LED
FX-301H
Infrared LED
FX-301P
Red LED
FX-301BP
Blue LED
FX-301GP
Green LED
FX-301HP
Infrared LED
Sub cable
Output
NPN open-collector
transistor
PNP open-collector
transistor
Quick-connection cable is not supplied with the amplifier. Please order it separately.
Model No.
Main cable
End plates
Model No.
Main cable
Description
CN-73-C1
Length: 1 m 3.281 ft
CN-73-C2
Length: 2 m 6.562 ft
CN-73-C5
Length: 5 m 16.404 ft
CN-71-C1
Length: 1 m 3.281 ft
CN-71-C2
Length: 2 m 6.562 ft
CN-71-C5
Length: 5 m 16.404 ft
• CN-73-C
0.15 mm2 3-core cabtyre cable, with connector on one end
Cable outer diameter: "3.0 mm "0.118 in
Sub cable
0.15 mm2 1-core cabtyre cable, with connector on one end
Cable outer diameter: "3.0 mm "0.118 in
• CN-71-C
End plates are not supplied with the amplifier. Please order separately when the amplifiers are mounted in cascade.
Appearance
Model No.
MS-DIN-E
Description
When cascading multiple amplifiers, or when it
moves depending on the way it is installed on a
DIN rail, these end plates ensure that all
amplifiers are mounted together in a secure and
fully connected manner.
Two pcs. per set
OPTIONS
Amplifier mounting bracket
Designation
Model No.
Amplifier mounting
bracket
MS-DIN-2
Mounting bracket for amplifier
FX-MB1
10 sets of 2 communication window seals and 1 connector seal
Communication window seal:
It prevents malfunction due to transmission signal from another
amplifier, as well as, prevents effect on another amplifier.
Connector seal:
It prevents contact of any metal, etc., with the pins of the quickconnection cable.
Fiber amplifier
protective seal
Description
• MS-DIN-2
Fiber amplifier protective seal
• FX-MB1
Communication
window seal
Connector seal
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
LIST OF FIBERS
Standard fibers [Thru-beam type (one pair set)]
"2.5
"0.098
Lens mountable
M4
M4
Lens mountable
Sleeve 90 mm 3.543 in
19,500 767,715 5,400 212.598 2,800 110.236 2.400 94.488 "0.4 mm
14,000 551.180 2,700 106.299 1,400 55.118 1,200 47.244
10 m
10,000 393.700 1,900 74.803 1,000 39.370 900 35.433 "0.016 in
(Note 3) opaque object 32.808 ft
3,800 149.606
1,600 62.992
400 15.748 200 7.874 155 6.102 "0.02 mm
800 31.496
200 7.874 100 3.937 77 3.031
2m
580 22.835
130 5.118 65 2.559 55 2.165 "0.0008 in
opaque object 6.562 ft R25 mm
280 11.024
R0.984 in
1,100 43.307
220 8.661 110 4.331 100 3.937 "0.04 mm
530 20.866
110 4.331 55 2.165 50 1.969
"0.0016
in
2m
400 15.748
75 2.953 40 1.575 30 1.181
opaque object 6.562 ft
180 7.087
1,000 39.370
200 7.874 100 3.937 90 3.543 "0.03 mm
480 18.898
100 3.937 50 1.969 45 1.772
2 m 6.562 ft
360 14.173
70 2.756 35 1.378 28 1.102 "0.0012 in
opaque object (Note 4)
168 6.614
M4
R25 mm
R0.984 in
M4
Fiber
R25 mm
R0.984 in
Sleeve
R10 mm
R0.394 in
"1.48 "0.058
Sleeve 40 mm 1.575 in
M4
"1.48 "0.058
Lens mountable
780 30.709
400 15.748
280 11.024
130 5.118
150 5.906
75 2.953
40 1.575
70 2.756
35 1.378
24 0.945
50 1.969 "0.03 mm
25 0.984
2m
18 0.709 "0.0012 in
opaque object 6.562 ft
M3
Standard
Sleeve 40 mm 1.575 in
M3
700 27.559
360 14.173
250 9.843
126 4.961
140 5.512
70 2.756
40 1.575
66 2.598
33 1.299
22 0.866
45 1.772 "0.03 mm
R25 mm
22 0.866
2 m 6.562 ft R0.984 in
17 0.669 "0.0012 in
opaque
object
(Note
4)
R25 mm
R0.984 in
270 10.630
140 5.512
100 3.937
49 1.929
50 1.969
25 0.984
16 0.630
24 0.945
12 0.472
8 0.315
16 0.630 "0.025 mm
8 0.315
2m
5 0.197 "0.0010 in
opaque object 6.562 ft
"0.88 "0.035
Elbow
"1.5
"0.059
Lens mountable
M4
FT-B8
FT-NB8
FT-FM2
FT-FM2S
FT-FM2S4
FT-SFM2
M3
"0.88 "0.035
FT-SFM2L
FT-T80
M3
Sleeve 90 mm 3.543 in
FT-FM10L
R25 mm
R0.984 in
"2.5
"0.098
M4
Model No.
530 20.866
230 9.055
150 5.906
80 3.150
85 3.346
42 1.654
28 1.102
400 15.748
200 7.874
130 5.118
80 3.150
40 1.575
28 1.102
50 1.969
25 0.984
16 0.630
28 1.102
14 0.551
10 0.394
44 1.732
22 0.866
16 0.630
200 7.874
100 3.937
65 2.559
40 1.575
20 0.787
14 0.551
26 1.024
13 0.512
8 0.315
14 0.551
7 0.276
5 0.197
32 1.260 "0.04 mm
16 0.630
2m
12 0.472 "0.0016 in
opaque object 6.562 ft
150 5.906 "0.05 mm
75 2.953
40 1.575 "0.0019 in
opaque object
2m
30 1.181
6.562 ft
15 0.591
12 0.472
44 1.732 "0.02 mm
1m
22 0.866
15 0.591 "0.0008 in
3.281 ft
opaque
object
10 0.394
5 0.197
2m
3 0.118
6.562 ft
Fiber
R25 mm
R0.984 in
Sleeve
FT-N8
FT-NFM2
FT-NFM2S
R10 mm
R0.394 in
FT-NFM2S4
R25 mm
R0.984 in
FT-SNFM2
R25 mm
R0.984 in
FT-R80
2,000 78.740
1,000 39.370
FT-V10
800 31.496
350 13.780
400 15.748
"1.5 "0.059
200 7.874
"2.5 "0.098
FT-SFM2SV2
0.8 0.031
140 5.512
70 2.756
Sleeve part cannot be bent.
R25 mm
390 15.354
R0.984 in
"1 "0.039
180 7.087
FT-V22
"2 "0.079
0.6 0.024
125 4.921
63 2.480
Sleeve part cannot be bent.
"1 "0.039
175 6.890
80 3.150
"2.5 "0.098
0.6 0.024
FT-V41
60 2.362
Sleeve part cannot be bent. 27 1.063
Notes: 1) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the infrared
type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can fluctuate.
Notes: 2) The minimum sensing object size is the value for red LED type. Please contact our office for information on the minimum sensing object size if using
amplifiers other than red LED type.
The optimum condition is the condition when the sensitivity is set so that the sensing output just changes to light incident operation in the object absent
condition.
Notes: 3) Sensing range for a 2 m 6.562 ft long fiber. A 10 m 32.808 ft long fiber will cause damping of the beam and cannot be used.
Notes: 4) The fiber cutter is not supplied as an accessory with FT-NB8 and FT-N8. Please order it separately.
"4 "0.157
Side-view
3
0.118
FX-301
With lens
Min. sensing object Fiber cable Allowable
under the optimum length
bending
Blue LED Green LED Infrared LED condition (Note 2)
: Free-cut radius
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected] 67
FX-303
M14
Red LED
:FAST
:S-D
Fiber
Selection
Long sensing range
With lens
:LONG
:STD
Sensing range (mm in ) (Note 1)
Digital Setting
FX-302
Shape of fiber head
(mm in)
Color Detection Analog Output Manually Set Bank Selection Unit
FX-311
FX-11A
FX-CH
FZ-10
Type
FIBER SENSORS
FX-301
LIST OF FIBERS
Sharp bending fibers / Flexible fibers [Thru-beam type (one pair set)]
Type
Rectangular head
Long sensing range Narrow beam
Sharp bending
Shape of fiber head
(mm in)
Wide area sensing
Sensing width
32 mm
1.260 in
W5H69D20
W0.197H2.717D0.787
Wide area sensing
Sensing width
11 mm
0.433 in
W4.2H31D13.5
W0.165H1.220D0.531
Easy mounting Top sensing
W3H8D12 W0.118H0.315D0.472
Easy mounting Side sensing
W3H12D8 W0.118H0.472D0.315
Easy mounting Front sensing
W8.5H12D3 W0.335H0.472D0.118
Side-view type with small light
dispersion "4 "0.157
3 0.118
With lens Long sensing range
"3 "0.118
Standard
Lens mountable
Sensing range (mm in) (Note 1)
Red LED
Side-view Small diameter
:FAST
:S-D
Min. sensing object Fiber cable Allowable
under the optimum length
bending
Blue LED Green LED Infrared LED condition (Note 2)
: Free-cut radius
FT-WA30
FT-WA8
3,500 137.795
1,500 59.055
1,100 43.307
750 29.528
600 23.622
300 11.811
220 8.661
300 11.811
150 5.906
110 4.331
220 8.661 "0.25 mm
110 4.331 "0.010 in
R1 mm
2m
80 3.150
R0.039 in
opaque object 6.562 ft
2,500 98.425
1,200 47.244
850 33.465
410 16.142
1,500 59.055
700 27.559
500 19.685
210 8.268
700 27.559
330 12.992
240 9.449
120 4.724
1,700 66.929
700 27.559
600 23.622
300 11.811
1,200 47.244
600 23.622
420 16.535
210 8.268
400 15.748
200 7.874
140 5.512
240 9.449
120 4.724
80 3.150
80 3.150
40 1.575
25 0.984
300 11.811
150 5.906
100 3.937
240 9.449
120 4.724
90 3.543
200 7.874
100 3.937
70 2.756
120 4.724
60 2.362
40 1.575
40 1.575
20 0.787
13 0.512
160 6.299
80 3.150
60 2.362
120 4.724
60 2.362
40 1.575
180 7.087 "0.08 mm
90 3.543 "0.003 in
65 2.559
opaque object
100 3.937 "0.05 mm
50 1.969 "0.0020 in
R1 mm
2m
30 1.181
R0.039 in
opaque
object
6.562
ft
570 22.441
290 11.417
200 7.874
100 3.937
M3
"1.5 "0.059
"1 "0.039
"2 "0.079
Sleeve part cannot be bent.
Easy mounting Top sensing
W3H8D12 W0.118H0.315D0.472
160 6.299
80 3.150
55 2.165
28 1.102
90 3.543
40 1.575
30 1.181
15 0.591
90 3.543
45 1.772
30 1.181
16 0.630
8 0.315
5 0.197
560 22.047
280 11.024
200 7.874
400 15.748
200 7.874
140 5.512
120 4.724
60 2.362
40 1.575
130 5.118
65 2.559
45 1.772
50 1.969
25 0.984
18 0.709
32 1.260
16 0.630
12 0.472
36 1.417
18 0.709
14 0.551
14 0.551
7 0.276
4 0.157
56 2.205
28 1.102
20 0.787
10 0.394
5 0.197
3 0.118
200 7.874
100 3.937
65 2.559
200 7.874
100 3.937
65 2.559
60 2.362
30 1.181
22 0.866
70 2.756
35 1.378
25 0.984
26 1.024
13 0.512
8 0.315
18 0.709
9 0.354
7 0.276
20 0.787
10 0.394
8 0.315
6 0.236
3 0.118
2 0.079
Model No.
800 31.496
400 15.748 "0.3 mm
R1 mm
240 9.449 "0.012 in
2m
opaque object 6.562 ft R0.039 in
36 1.417 "0.04 mm
18 0.709 "0.0016 in
12 0.472
opaque object
150 5.906 "0.06 mm
75 2.953 "0.0024 in
2m
45 1.772
opaque object 6.562 ft
110 4.331 "0.02 mm
55 2.165 "0.0008 in
2m
35 1.378
opaque object 6.562 ft
M4
"3
"0.118
1 0.039
:LONG
:STD
3,500 137.795 2,400 94.488 1,200 47.244
3,500 137.795 1,200 47.244 600 23.622
3,500 137.795 700 27.559 350 13.780
3,500 137.795
(Note 3)
"2.5
"0.098
42 1.654
21 0.827
15 0.591
FT-WZ8E
FT-WZ8
R1 mm
R0.039 in
FT-WKV8
R1 mm
R0.039 in
FT-WS8L
"0.03 mm
"0.0012 in
opaque object
"0.05 mm
R1 mm
"0.0020 in
2m
opaque object 6.562 ft R0.039 in
"0.03 mm
"0.0012 in
opaque object
8 0.315 "0.02 mm
4 0.157 "0.0008 in
2m
2.5 0.098
opaque object 6.562 ft
"0.02 mm
"0.0008 in
2m
opaque object 6.562 ft
FT-WZ8H
R1 mm
R0.039 in
R1 mm
R0.039 in
FT-W8
FT-WS3
FT-WS8
FT-W4
FT-WS4
FT-WV42
Small diameter
Standard
Rectangular head
180 7.087
2,700 106.299
90 3.543
1,400 55.118
FT-Z8H
65 2.559
1,000 39.370
490 19.291
Easy mounting Side sensing
140 5.512 "0.03 mm
1,600 62.992
W3H12D8 W0.118H0.472D0.315
70 2.756 "0.0012 in
800 31.496
R4 mm
FT-Z8E
2m
50 1.969
600 23.622
R0.157 in
opaque object 6.562 ft
280 11.024
Easy mounting Front sensing
46 1.811
800 31.496
W8.5H12D3 W0.335H0.472D0.118
23 0.906
400 15.748
FT-Z8
16 0.630
300 11.811
140 5.512
56 2.205
650 25.591
Lens mountable
M4
28 1.102
320 12.598
FT-P80
20 0.787
230 9.055
"0.04 mm
110 4.331
R4
mm
"0.0016 in
2m
R0.157 in
20 0.787 opaque object
400 15.748
Lens mountable
M4
6.562 ft
10 0.394
190 7.480
FT-P60
7 0.276
140 5.512
80 3.150
14 0.551
250 9.843
M3
7 0.276
100 3.937
FT-P40
2m
5 0.197
75 2.953
6.562 ft
35 1.378
18 0.709 "0.02 mm
280 11.024
"1.5
1m
9 0.354 "0.0008 in
120 4.724
R4 mm
"0.059
FT-P2
7 0.276
90 3.543
3.281 ft R0.157 in
opaque object
42 1.654
14 0.551
80 3.150
"1
500 mm
7 0.276
40 1.575
"0.039
FT-PS1
4 0.157
30 1.181
19.685 in
17 0.669
Notes: 1) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the infrared
type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can fluctuate.
Notes: 2) The minimum sensing object size is the value for red LED type. Please contact our office for information on the minimum sensing object size if using amplifiers other than red LED
type. The optimum condition is the condition when the sensitivity is set so that the sensing output just changes to light incident operation in the object absent condition.
Notes: 3) The fiber cable length practically limits the sensing range to 3,500 mm 137.795 in long.
Flexible
FZ-10
FX-11A
FX-CH
FX-311
Color Detection Analog Output Manually Set Bank Selection Unit
FX-303
FX-302
Digital Setting
FX-301
Wide beam
Fiber
Selection
FIBER SENSORS
FX-301
68 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
LIST OF FIBERS
Special use fibers [Thru-beam type (one pair set)]
W5H69D20
W0.197H2.717D0.787
Sensing width
11 mm
0.433 in
W4.2H31D13.5
W0.165H1.220D0.531
Top sensing
W5H15D15 W0.197H0.591D0.591
Side sensing
W5H15D15 W0.197H0.591D0.591
800 31.496
400 15.748 "0.3 mm
R10 mm
2m
240 9.449 "0.012 in
R0.394 in
opaque object 6.562 ft
3,500 137.795
1,500 59.055
1,100 43.307
750 29.528
650 25.591
330 12.992
220 8.661
115 4.528
590 23.228
290 11.417
200 7.874
100 3.937
600 23.622
300 11.811
220 8.661
120 4.724
60 2.362
40 1.575
120 4.724
60 2.362
40 1.575
300 11.811
150 5.906
110 4.331
60 2.362
30 1.181
20 0.787
60 2.362
30 1.181
20 0.787
220 8.661 "0.25 mm
110 4.331 "0.010 in
R10 mm
2m
80 3.150
R0.394 in
opaque object 6.562 ft
2,000 78.740
1,000 39.370
800 31.496
350 13.780
400 15.748
200 7.874
130 5.118
200 7.874
100 3.937
65 2.559
150 5.906 "0.06 mm
R25 mm
75 2.953 "0.0024 in
2m
R0.984 in
40 1.575
opaque
object
6.562
ft
80 3.150
35 1.378
10 0.394
3 0.118
2 0.079
1 0.039
14 0.551
7 0.276
4 0.157
130 5.118
64 2.520
45 1.772
0.039
0.236
0.118
0.079
2.520
1.260
0.866
48 1.890 Horizontal:
24 0.945 "0.025 mm
18 0.709 "0.0010 in
opaque object
R25 mm
2m
R0.984 in
48 1.890 Vertical:
6.562 ft
24 0.945 "0.45 mm
18 0.709 "0.018 in
opaque object
Model No.
FT-A30
FT-A8
FT-AFM2
FT-AFM2E
Narrow beam
Special use
"3.5
"0.138
"3.7
"0.146
Side-view
"4 "0.157
FT-KV8
3 0.118
Side-view
W2H1.5D20 W0.079H0.059D0.787
2
Tough flexible Ultra-small diameter
FT-K8
0.079
Beam diameter: "0.125 mm "0.005 in
"0.25 "3
"0.010 "0.118
Sleeve part cannot be bent.
Beam diameter: "0.25 mm "0.010 in
"0.4 "3
"0.016 "0.118
Sleeve part cannot be bent.
Lens mountable
M4
500 19.685
250 9.843
180 7.087
100 3.937
18 0.709
10 0.394
8 0.315
3 0.118
80 3.150
50 1.969
36 1.417
15 0.591
650 25.591
320 12.598
230 9.055
110 4.331
1
6
3
2
64
32
22
4
2
1.5
10
5
3
130
64
45
0.157
0.079
0.059
0.394
0.197
0.118
5.118
2.520
1.772
"0.02 mm
R10 mm
"0.0008 in
2m
R0.394 in
opaque object 6.562 ft
"0.02 mm
"0.0008 in
opaque object
500 mm
19.685 in
FT-KV1
FX-301
Min. sensing object Fiber cable Allowable
bending
under the optimum length
Blue LED Green LED Infrared LED condition (Note 2)
: Free-cut radius
3,500 137.795 2,400 94.488 1,200 47.244
3,500 137.795 1,200 47.244 600 23.622
3,500 137.795 700 27.559 350 13.780
3,500 137.795
(Note 3)
Sensing width
32 mm
1.260 in
:FAST
:S-D
FX-303
Red LED
:LONG
:STD
Fiber
Selection
Sensing range (mm in) (Note 1)
Digital Setting
FX-302
Shape of fiber head
(mm in)
FT-E12
R5 mm
R0.197 in
1m
3.281 ft
"0.05 mm
1m
R10 mm
"0.0020 in
3.281 ft R0.394 in
opaque object
FT-E22
FT-P81X
Notes: 1) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the
infrared type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can
fluctuate.
Notes: 2) The minimum sensing object size is the value for red LED type. Please contact our office for information on the minimum sensing object size if using
amplifiers other than red LED type.
The optimum condition is the condition when the sensitivity is set so that the sensing output just changes to light incident operation in the object absent
condition.
Notes: 3) The fiber cable length practically limits the sensing range to 3,500 mm 137.795 in long.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected] 69
Color Detection Analog Output Manually Set Bank Selection Unit
FX-311
FX-11A
FX-CH
FZ-10
Array
Wide beam
Type
FIBER SENSORS
FX-301
FIBER SENSORS
FX-301
LIST OF FIBERS
Environment resistant fibers [Thru-beam type (one pair set)]
Fiber
Selection
Type
Shape of fiber head
(mm in)
350 C 662 F
Lens mountable
M4
350 C 662 F
Sleeve 60 mm 2.362 in M4
Sensing range (mm in) (Note 1)
Red LED
550 21.654
280 11.024
200 7.874
90 3.543
Min. sensing object Fiber cable Allowable
under the optimum length
bending
Blue LED Green LED Infrared LED condition (Note 2)
: Free-cut radius
:LONG
:STD
:FAST
:S-D
R25 mm
R0.984 in
420 16.535 "0.04 mm
2m
210 8.268 "0.0016 in
Fiber
160 6.299
6.562 ft R25
mm
opaque object
R0.984 in
100 3.937
50 1.969
35 1.378
50 1.969
25 0.984
18 0.709
44 1.732
22 0.866
14 0.551
22 0.866
11 0.433
7 0.276
1m
3.281 ft
220 8.661 "0.02 mm
110 4.331 "0.0008 in
R10 mm
70 2.756
R0.394 in
opaque object
2m
6.562 ft
100 3.937
50 1.969
35 1.378
72 2.835
36 1.417
26 1.024
50 1.969
25 0.984
18 0.709
32 1.260
16 0.630
10 0.394
420 16.535 "0.04 mm
1m
210 8.268 "0.0016 in
160 6.299
3.281 ft
opaque
object
R25 mm
R0.984 in
70 2.756 "0.06 mm
35 1.378 "0.0024 in
2
m
25 0.984
opaque object 6.562 ft
320 12.598
160 6.299
120 4.724
160 6.299
80 3.150
60 2.362
320 12.598 "4 mm
R25 mm
160 6.299
2m
120 4.724 "0.157 in
6.562 ft R0.984 in
opaque
object
Sleeve
R10 mm
R0.394 in
Heat-resistant
Allows flexible wiring
200 C 392 F
Lens mountable
M4
M4
130 C 266 F
Lens mountable
M4
Easy mounting Rectangular head
SEMI S2 compliant
W7H15D13
W0.276H0.591D0.512
Chemical-resistant
Environment resistant
200 C 392 F
Lens mountable
310 12.205
140 5.512
100 3.937
50 1.969
550 21.654
280 11.024
200 7.874
90 3.543
880 34.646
440 17.323
300 11.811
155 6.102
3,500 137.795
1,500 59.055
1,000 39.370
530 20.866
FT-H35-M2
FT-H35-M2S6
FT-H20W-M1
FT-H20W-M2
FT-H20-M1
FT-H13-FM2
FT-Z802Y
3,500 137.795 160 6.299 160 6.299 400 15.748
80 3.150 80 3.150 200 7.874
1,500 59.055
FT-L8Y
50 1.969 50 1.969 150 5.906
1,000 39.370
"0.08 mm
530 20.866
2
m
R30
mm
"0.003 in
Side-view "5.5 "0.217
120 4.724 80 3.150 75 2.953 opaque object 6.562 ft R1.181 in
800 31.496
60 2.362 40 1.575 38 1.496
400 15.748
(Note 3)
FT-V8Y
35 1.378 25 0.984 24 0.945
280 11.024
140 5.512
Lens mountable
100 3.937 46 1.811 70 2.756
470 18.504
50 1.969 23 0.906 35 1.378
R200 mm
230 9.055
FT-6V
30 1.181 16 0.630 22 0.866
165 6.496
R7.874 in
M4
"0.02 mm
80 3.150
1m
"0.0008 in
36 1.417 18 0.709 28 1.102 opaque object 3.281 ft
220 8.661
18 0.709
9 0.354 14 0.551
R30 mm
100 3.937
FT-60V
12 0.472
6 0.236 10 0.394
75 2.953
R1.181 in
35 1.378
Notes: 1) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the infrared
type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can fluctuate.
Notes: 2) The minimum sensing object size is the value for red LED type. Please contact our office for information on the minimum sensing object size if using amplifiers other than red
LED type. The optimum condition is the condition when the sensitivity is set so that the sensing output just changes to light incident operation in the object absent condition.
Notes: 3) The allowable cutting range is 500 mm 19.685 in from the end that the amplifier inserted.
"5.5
"0.217
Vacuum
The vacuum type fiber must be used with the following products as a set.
FT-J6: Fiber at atmospheric side (one pair set) FV-BR1: Photo-terminal (one pair set)
Semi-standard fibers (Custom made per order)
The fiber cable length or sleeve length of the standard fibers can be modified at your request. Select the fiber cable length (symbol ) or the sleeve length
(symbol f ) from the table below.
Type
Basic model No.
Fiber cable length
(Unit: m ft)
f Sleeve length
(Unit: cm in)
Standard threaded
FT-FM head (free-cut)
3 9.843, 4 13.123, 5 16.404, 10 32.808,
15 49.213, 20 65.617,25 82.021, 30 98.425
2 6.562 (Note), 3 9.843, 4 13.123, 5 16.404, 1 0.394, 2 0.787, 3 1.181, 4 1.575, 5 1.969, 6 2.362,
With sleeve FT-FM -S f
10 32.808, 15 49.213, 20 65.617, 25 82.021, 30 98.425 7 2.756, 8 3.150, 9 3.543, 10 3.937, 11 4.331, 12 4.724
With large diameter lens FT-FM L
20 65.617, 30 98.425
Small diameter threaded
1 0.394, 2 0.787, 3 1.181, 4 1.575, 5 1.969, 6 2.362,
FT-NFM2-S
f
head with sleeve (free-cut)
7 2.756, 8 3.150, 9 3.543, 10 3.937, 11 4.331, 12 4.724
FT-WA30- FT-WA8- Wide beam
FT-A30- FT-A8- 200C 392F heat-resistant FT-H20-M 350C 662F heat-resistant FT-H35-M Chemical-resistant FT-Z80 Y
5 16.404
2 6.562, 3 9.843
3 9.843
5 16.404, 7 22.966
Note: The standard fiber has a 2 m 6.562 ft fiber cable length and a 4 cm 1.575 in or 9 cm 3.543 in sleeve length.
Correlation between sensing
range attenuation coefficient and
fiber cable length
The longer the fiber cable, the shorter the
sensing range.
1.2
1.0
Sensing range
attenuation coefficient
FZ-10
FX-11A
FX-CH
FX-311
Color Detection Analog Output Manually Set Bank Selection Unit
FX-303
FX-302
Digital Setting
FX-301
"2.1 "0.083
Model No.
0.8
0.6
0.4
0.2
0
5 10 15 20 25 30
16.404 32.808 49.213 65.617 82.021 98.425
Fiber cable length # (m ft)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
LIST OF FIBERS
Standard fibers (Reflective type)
80 3.150
40 1.575
26 1.024
46 1.811
23 0.906
15 0.591
46 1.811
23 0.906
15 0.591
42 1.654
21 0.827
14 0.551
24 0.945
12 0.472
8 0.315
24 0.945
12 0.472
8 0.315
26 1.654
13 0.827
9 0.551
90 3.543
45 1.772
30 1.181
20 0.787
10 0.394
7 0.276
"0.02 mm
"0.0008 in
gold wire
75 2.953
Coaxial
310 12.205
140 5.512
100 3.937
47 1.850
310 12.205
140 5.512
100 3.937
47 1.850
46 1.811
23 0.906
15 0.591
24 0.945
12 0.472
8 0.315
20 0.787
10 0.394
7 0.276
"0.02 mm
"0.0008 in
gold wire
46 1.811
23 0.906
15 0.591
16 0.630
8 0.315
5 0.197
46 1.811
23 0.906
15 0.591
46 1.811
23 0.906
15 0.591
16 0.630
8 0.315
5 0.197
24 0.945
12 0.472
8 0.315
8 0.315
4 0.157
2 0.079
24 0.945
12 0.472
8 0.315
24 0.945
12 0.472
8 0.315
8 0.315
4 0.157
2 0.079
20 0.787
10 0.394
7 0.276
6 0.236
3 0.118
2 0.079
20 0.787
10 0.394
7 0.276
20 0.787
10 0.394
7 0.276
4 0.157
2 0.079
1.5 0.059
"0.02 mm
"0.0008 in
gold wire
270 10.630
110 4.331
85 3.346
39 1.535
"2.5
"0.098
270 10.630
M4
Small diameter
M3
Standard
"3
"0.118
110 4.331
85 3.346
39 1.535
90 3.543
45 1.772
35 1.378
16 0.630
270 10.630
110 4.331
85 3.346
39 1.535
260 10.236
120 4.724
85 3.346
42 1.654
75 2.953
38 1.496
28 1.102
13 0.512
M6
M4
500 mm R25 mm
19.685 in R0.984 in
Fiber
R25 mm
R0.984 in
2m
Sleeve
6.562 ft R10 mm
R0.394 in
"0.02 mm
"0.0008 in
gold wire
R25 mm
2m
R0.984 in
6.562 ft
8 0.315
4 0.157
2 0.079
6 0.236
3 0.118
2 0.079
"0.02 mm
"0.0008 in
gold wire
"1.48
"0.058
2m
R25 mm
6.562 ft R0.984 in
(Note 4)
Fiber
R25 mm
R0.984 in
2m
Sleeve
6.562 ft
R10 mm
R0.394 in
Side-view
Elbow
"2.5
"0.098
M6
"2
"0.079
"5
0.8
0.0.31
"0.197
Sleeve part cannot be bent.
Small diameter
"1.5
"0.059
"3
0.7 0.028
"0.118
Sleeve part cannot be bent.
R25 mm
R0.984 in
185 7.283
85 3.346
60 2.362
30 1.181
100 3.937
45 1.772
32 1.260
16 0.630
55 2.165
25 0.984
17 0.669
9 0.354
32 1.260
16 0.630
10 0.394
14 0.551
7 0.276
4 0.157
6 0.236
3 0.118
16 0.630
8 0.315
5 0.197
7 0.276
3.5 0.138
3 0.118
10 0.472
5 0.197
3 0.118
4 0.157
FD-T40
FD-N8
"0.02 mm
"0.0008 in
gold wire
Sleeve 90 mm 3.543 in
M4
16 0.630
8 0.315
5 0.197
FD-FM2S4
FD-S80
R25 mm
R0.984 in
90 3.543
45 1.772
35 1.378
16 0.630
FD-FM2S
FD-T80
M4
"1.48
"0.058
Sleeve 40 mm 1.575 in
M4
FD-5
FD-FM2
2m
6.562 ft
Sleeve 90 mm 3.543 in
M6
"2.5
"0.098
Sleeve 40 mm 1.575 in
M6
FD-B8
2m
6.562 ft
"0.02 mm
"0.0008 in
gold wire
R25 mm
2m
R0.984 in
6.562 ft
"0.02 mm
"0.0008 in
gold wire
R25 mm
R0.984 in
FD-N4
FD-NFM2
FD-NFM2S
FD-NFM2S4
FD-SNFM2
FD-R80
FD-SFM2SV2
2m
6.562 ft
FX-301
480 18.898
220 8.661
160 6.299
Model No.
FD-V41
Notes: 1) The sensing range is specified for white non-glossy paper (FD-B8, FD-5, FD-FM2, FD-FM2S, FD-FM2S4, FD-N8, FD-T80, FD-S80 and FD-R80:
400400 mm 15.74815.748 in, FD-T40, FD-N4, FD-NFM2, FD-NFM2S, FD-NFM2S4, FD-SNFM2, FD-SFM2SV2 and FD-V41: 200200 mm
7.8747.874 in) as the object.
Notes: 2) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the
infrared type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can
fluctuate.
Notes: 3) The minimum sensing object size is the value for red LED type at maximum sensitivity. Please contact our office for information on the minimum
sensing object size if using amplifiers other than red LED type.
Also, note that the corresponding setting distance is different from the rated sensing distance.
Notes: 4) The fiber cutter is not supplied as an accessory with FD-N8 and FD-N4. Please order it separately.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected] 71
FX-303
Red LED
M6
M6
:FAST
:S-D
Fiber
Selection
Min. sensing object Fiber cable Allowable
at the maximum length
bending
Blue LED Green LED Infrared LED sensitivity (Note 3)
: Free-cut radius
:LONG
:STD
Sensing range (mm in ) (Note 1, 2)
Digital Setting
FX-302
Shape of fiber head
(mm in)
Color Detection Analog Output Manually Set Bank Selection Unit
FX-311
FX-11A
FX-CH
FZ-10
Long sensing range
Type
FIBER SENSORS
FX-301
FIBER SENSORS
FX-301
LIST OF FIBERS
Sharp bending fibers / Flexible fibers (Reflective type)
Long sensing range
Fiber
Selection
Type
Shape of fiber head
(mm in)
Long sensing range Rectangular head
W5.2H9.5D15
W5.2H9.5
W5.2
H9.5D15
D15 mm
W0.205H0.374D0.5911
W0.205H0.374
W0.205
H0.374D0.5911
D0.5911 in
M6
Min. sensing object Fiber cable Allowable
bending
at the maximum length
Blue LED Green LED Infrared LED sensitivity (Note 3)
: Free-cut radius
:LONG
:STD
:FAST
:S-D
23 0.906
11 0.433
8 0.315
14 0.551
7 0.276
4 0.157
11 0.433
5.5 0.217
3 0.118
5 0.197
2.5 0.098
1.5 0.059
3 0.118
1.5 0.059
1 0.039
2 0.079
1 0.039
Sensing range (mm in) (Note 1, 2)
Red LED
20 to 480 0.787 to 18.898
20 to 230 0.787 to 9.055
20 to 170 0.787 to 6.693
25 to 100 0.984 to 3.937
190 7.480
90 3.543
60 2.362
32 1.260
"0.3 mm
"0.012 in
copper wire
R1 mm
2m
R0.039 in
6.562 ft
M4
Standard
"1.48
"0.058
Sharp bending
"0.02 mm
"0.0008 in
gold wire
190 7.480
90 3.543
60 2.362
32 1.260
30 1.181
15 0.591
12 0.472
5 0.197
Side-view Fixed-focus reflective
High precision
M3
Standard
FD-W8
Fiber
R1 mm
R0.039 in
Sleeve
R10 mm
R0.394 in
FD-W44
2m
6.562 ft
23 0.906
11 0.433
8 0.315
14 0.551
7 0.276
4 0.157
11 0.433
5.5 0.217
3 0.118
5 0.197
2.5 0.098
1.5 0.059
3 0.118
1.5 0.059
1 0.039
2 0.079
1 0.039
M4
For sensing minute objects Coaxial
"3
"0.118
Glass substrate detection
W24H21D4
W0.945H0.8270.157
Specular object detection
W15H19D3
W0.591H0.7480.118
"2
"0.079
"3
1 0.039
"0.118
Sleeve part cannot be bent.
65 2.559
32 1.260
25 0.984
11 0.433
11 0.433
5 0.197
3 0.118
6 0.236
3 0.118
2 0.079
5 0.197
2.5 0.098
1.5 0.059
6.5 to 14 0.256 to 0.551 (Convergent point 8 0.315)
7 to 12 0.276 to 0.472 (Convergent point 8 0.315)
7.5 to 12 0.295 to 0.472 (Convergent point 8 0.315)
Cannot use
0.6 to 3.5 0.024 to 0.138 (Convergent point 2 0.079)
0.9 to 2.7 0.035 to 0.106 (Convergent point 2 0.079)
1 to 2.5 0.039 to 0.098 (Convergent point 2 0.079)
Cannot use
15 0.591
7 0.276
5 0.197
Cannot use
220 8.661
100 3.937
70 2.756
35 1.378
40 1.575
20 0.787
13 0.512
20 0.787
10 0.394
7 0.276
"1.9 mm
"0.075 in
metal pipe (gray)
2m
"0.08 mm
6.562 ft
"0.003 in
gold wire
"0.02 mm
2m
"0.0008 in
6.562 ft
gold wire
18 0.709
9 0.354
6 0.236
20 0.787
10 0.394
6 0.236
10 0.394
5 0.197
3 0.118
8 0.315
4 0.157
2.5 0.098
FD-WKZ1
R1 mm
R0.039 in
FD-WT8
R1 mm
R0.039 in
FD-WS8
FD-WT4
Small spot for sensing minute objects
Coaxial Lens mountable
M6
"0.02 mm
"0.0008 in
gold wire
FD-WG4
2m
6.562 ft
R2 mm
R0.079 in
FD-WSG4
FD-WL41
R1 mm
R0.039 in
FD-WL42
R1 mm
R0.039 in
FD-WV42
FD-P80
M4
"3
"0.118
Small diameter
30 1.181
15 0.591
12 0.472
5 0.197
M4
"3
"0.118
Flexible
FZ-10
FX-11A
FX-CH
FX-311
Color Detection Analog Output Manually Set Bank Selection Unit
FX-303
FX-302
Digital Setting
FX-301
Sleeve 40 mm 1.575 in
Model No.
M3
"1.5
"0.059
90 3.543
45 1.772
30 1.181
16 0.630
36 1.417
18 0.709
14 0.551
6 0.236
50 1.969
25 0.984
19 0.748
9 0.354
5 0.197
2.5 0.098
1.5 0.059
8 0.315
4 0.157
2.5 0.098
3 0.118
1.5 0.059
1 0.039
4 0.157
2 0.079
1.5 0.059
2 0.079
1 0.039
7 0.276
3.5 0.138
2 0.079
FD-P60
"0.02 mm
"0.0008 in
gold wire
2m
6.562 ft
R4 mm
R0.157 in
FD-P50
FD-P40
1m
3.281 ft
FD-P2
Notes: 1) The sensing range is specified for white non-glossy paper [100100 mm 3.9373.937 in (FD-WKZ1, FD-W8, FD-WT8, FD-WS8 and FD-P80:
400 400 mm 15.748 15.748 in, FD-WG4, FD-WSG4, FD-P60 and FD-P50: 200 200 mm 7.874 7.874 in, FD-WL41: glass substrate
100100t 2 mm 3.9373.937t 0.472 in)] as the object.
Notes: 2) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the
infrared type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can
fluctuate.
Notes: 3) The minimum sensing object size is the value for red LED type at maximum sensitivity. Please contact our office for information on the minimum
sensing object size if using amplifiers other than red LED type.
Also, note that the corresponding setting distance is different from the rated sensing distance. However, with the fixed-focus reflective type, when the
sensitivity is at MAX., it is only possible to detect the minimum size of the sensing object at a distance corresponding to the convergent point.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
LIST OF FIBERS
Special use fibers (Reflective type)
High precision
Ultra-small diameter
Fixed-focus reflective
"0.02 mm
"0.0008 in
gold wire
R25 mm
2m
R0.984 in
6.562 ft
220 8.661
110 4.331
78 3.071
40 1.575
20 0.787
13 0.512
18 0.709
9 0.354
5 0.197
12 0.472
6 0.236
4 0.157
"0.02 mm
"0.0008 in
gold wire
R25 mm
2m
R0.984 in
6.562 ft
22 0.866
11 0.433
8 0.315
12 0.472
6 0.236
4 0.157
7 0.276
3.5 0.138
2 0.079
39 1.535
110 4.331
55 2.165
42 1.654
19 0.748
"0.02 mm
"0.0008 in
gold wire
38 1.496
18 0.709
14 0.551
6 0.236
6 0.236
3 0.118
2 0.079
3 0.118
1.5 0.059
1 0.039
10 0.394
5 0.197
3 0.118
Coaxial Lens mountable
M3
25 0.984
12 0.472
9 0.354
5 0.197
5 0.197
2 0.079
1 0.039
2 0.079
1 0.039
6 0.236
3 0.118
2 0.079
2 0.079
1 0.039
1 0.039
3 0.118
1.5 0.059
1 0.039
2 0.079
1 0.039
1 0.039
1 0.039
6 0.236
3 0.118
2 0.079
3 0.118
1.5 0.059
1 0.039
6 0.236
3 0.118
2 0.079
6 0.236
3 0.118
2 0.079
3 0.118
1.5 0.059
1 0.039
4 0.157
2 0.079
1.5 0.059
(LCD glass)
2.5 to 18 0.098 to 0.709 (Convergent point 8 0.315)
3 to 16 0.118 to 0.630 (Convergent point 8 0.315)
3.5 to 15 0.138 to 0.591 (Convergent point 8 0.315)
Cannot use
"0.06 mm
"0.0024 in
gold wire
0.5 to 4 0.020 to 0.157 (Convergent point 2 0.079)
1 to 3.8 0.039 to 0.150 (Convergent point 2 0.079)
1.3 to 3.5 0.051 to 0.138 (Convergent point 2 0.079)
Cannot use
"0.03 mm
"0.0012 in
gold wire
5 to 9 0.197 to 0.354 4.5 to 9.5 0.177 to 0.374
5.5 to 8 0.217 to 0.315
"0.02 mm
"0.0008 in
gold wire
Sleeve part cannot be bent.
Coaxial "3 "0.65
"0.118 "0.026
Sleeve part cannot be bent.
"0.5
M3
"0.020
Sleeve part cannot be bent.
Coaxial
"0.8
M3 "0.031
Sleeve part cannot be bent.
Glass substrate detection SEMI S2 compliant
W17H29D3.8
W0.669H1.142D0.150
Glass substrate detection
W24H21D4
W0.945H0.827D0.157
Specular object detection W15H19D3
W0.591H0.748D0.118
W6H18D14
W0.236H0.709D0.551
11 0.433
6 0.236
4 0.157
1 0.039
45 1.772
23 0.906
17 0.669
7 0.276
5 0.197
3 0.118
2 0.079
Cannot use
38 1.496
18 0.709
14 0.551
6 0.236
0 to 20 0 to 0.787
2.5 to 18 0.098 to 0.709 (Convergent point 6 0.236) 4.5 to 9.5 0.177 to 0.374
4 to 12 0.157 to 0.472 (Convergent point 6 0.236) 5 to 9 0.197 to 0.354
4.5 to 11 0.177 to 0.433 (Convergent point 6 0.236) 5.5 to 8 0.217 to 0.315
4.8 to 9.5 0.189 to 0.374 (Convergent point 6 0.236)
Contact type
"6 "0.236
Mountable on pipe Standard
W25H13D20
W0.984H0.512D0.787
Mountable on pipe For PFA, wall
thickness 1 mm 0.039 in pipe
W25H13D20
W0.984H0.512D0.787
M6
Small spot for sensing minute objects
M3
Coaxial High precision
Applicable pipe diameter:
Outer dia. "6 to "26 mm "0.236 to "1.024 in transparent pipe
[PFA (fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in]
185 7.283
80 3.150
60 2.362
35 1.378
90 3.543
45 1.772
35 1.378
20 0.787
32 1.260
16 0.630
10 0.394
16 0.630
8 0.315
5 0.197
30 1.181
15 0.591
10 0.394
22 0.866
11 0.433
6 0.236
12 0.472
6 0.236
4 0.157
18 0.709
9 0.354
5 0.197
FD-AFM2E
2m
6.562 ft R25 mm
R0.984 in
FD-G6
FD-EG1
"0.04 mm
"0.0016 in
gold wire
500 mm
19.685 in
"0.02 mm
"0.0008 in
gold wire
(Liquid)
"0.02 mm
"0.0008 in
gold wire
FD-EG2
R10 mm
R0.394 in
FD-EG3
1m
3.281 ft
(Liquid)
Applicable pipe diameter:
Outer dia. "6 to "26 mm "0.236 to "1.024 in transparent pipe
[PVC, fluorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm 0.039 to 0.118 in]
FD-AFM2
FD-G4
Coaxial Lens mountable
M3
15 0.591
8 0.315
5 0.197
3 0.118
FD-A15
R10 mm
R0.394 in
FD-E12
FX-301
FX-303
Side sensing
W5H20D20
W0.197H0.787D0.787
Coaxial Lens mountable
M4
"1.5 "0.5
"0.059 "0.020
Liquid level sensing
25 0.984
15 0.591
Model No.
Fiber
Selection
Top sensing
W5H20D20
W0.197H0.787D0.787
:FAST
:S-D
200 7.874
150 5.906
100 3.937
50 1.969
Coaxial Lens mountable
M3
Tough flexible
Red LED
W7H15D30 W0.276H0.591D1.181
Coaxial Lens mountable
M3
Special use
Min. sensing object Fiber cable Allowable
at the maximum length
bending
Blue LED Green LED Infrared LED sensitivity (Note 3)
: Free-cut radius
:LONG
:STD
Sensing range (mm in) (Note 1, 2)
Digital Setting
FX-302
Shape of fiber head
(mm in)
FD-E22
500 mm R25 mm
19.685 in R0.984 in
FD-EN500S1
1m
3.281 ft
FD-ENM1S1
R4
R0.157
FD-L43
FD-L41
2m
6.562 ft R10 mm
R0.394 in
FD-L42
FD-L4
2 m 6.562 ft
(Note 4)
2m
6.562 ft
5m
16.404 ft
2m
6.562 ft
5m
16.404 ft
Protective tube
R40 mm R1.575 in
Fiber
R15 mm R0.591 in
FD-F8Y
FD-F41
R10 mm
R0.394 in
FD-F91
FD-F4
FD-F9
1m
3.281 ft
FD-P81X
R10 mm
R0.394 in
1 m 3.281 ft
FD-G6X
(Note 4)
Notes: 1) The sensing range is specified for white non-glossy paper [100100 mm 3.9373.937 in (FD-A15, FD-G4, FD-G6X: 200200 mm 7.8747.874 in,
FD-AFM2, FD-AFM2E, FD-P81X: 400400 mm 15.74815.748 in, FD-L43: glass substrate 7652t 1.1 mm 2.9922.047t 0.043 in, FD-L41:
glass substrate 100100t 2 mm 3.9373.937t 0.079 in)] as the object.
Notes: 2) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the
infrared type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can
fluctuate.
Notes: 3) The minimum sensing object size is the value for red LED type at maximum sensitivity. Please contact our office for information on the minimum
sensing object size if using amplifiers other than red LED type.
Also, note that the corresponding setting distance is different from the rated sensing distance. However, with the fixed-focus reflective type, when the
sensitivity is at MAX., it is only possible to detect the minimum size of the sensing object at a distance corresponding to the convergent point.
Notes: 4) Following is the allowable cutting range from the end that the amplifier is inserted FD-F8Y: 1,000 mm 39.370 in, FD-G6X: 700 mm 27.559 in.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected] 73
Color Detection Analog Output Manually Set Bank Selection Unit
FX-311
FX-11A
FX-CH
FZ-10
Array
Wide beam
Type
FIBER SENSORS
FX-301
LIST OF FIBERS
Environment resistant fibers (Reflective type)
Type
Min. sensing object Fiber cable Allowable
bending
at the maximum length
Blue LED Green LED Infrared LED sensitivity (Note 3)
: Free-cut radius
:LONG
:STD
Sensing range (mm in) (Note 1, 2)
Red LED
:FAST
:S-D
270 10.630
140 5.512
100 3.937
47 1.850
36 1.417
18 0.709
12 0.472
20 0.787
10 0.394
7 0.276
140 5.512
70 2.756
45 1.772
"0.02 mm
"0.0008 in
gold wire
200 C 392 F Coaxial
M6
Heat-resistant
350 C 662 F Sleeve 90 mm 3.543 in
Environment resistant
M4
"2.1
"0.083 in
200 C 392 F Coaxial
M4
180 C 356 F Glass substrate detection
Fixed-focus reflective type
W19H27D5
W0.748H1.063
D0.197
Vacuum
130 C 266 F
M6
M6
R25 mm
R0.984 in
FD-H35-M2
Fiber
R25 mm
R0.984 in
Sleeve
R10 mm
R0.394 in
FD-H35-M2S6
1 m R25 mm
3,281 ft R0.984 in
160 6.299
80 3.150
57 2.244
26 1.024
270 10.630
140 5.512
100 3.937
47 1.850
22 0.866
11 0.433
7 0.276
36 1.417
18 0.709
12 0.472
12 0.472
6 0.236
4 0.157
20 0.787
10 0.394
7 0.276
80 3.150
40 1.575
28 1.102
140 5.512
70 2.756
45 1.772
0 to 15 0 to 0.591
0 to 10 0 to 0.394
1 to 8 0.039 to 0.315
2 to 6 0.079 to 0.236
310 12.205
140 5.512
100 3.937
47 1.850
165 6.496
75 2.953
52 2.047
26 1.024
20 0.787
11 0.433
7 0.276
26 1.024
13 0.512
9 0.354
20 0.787
11 0.433
7 0.276
14 0.551
7 0.276
4 0.157
25 0.984
12 0.472
8 0.315
21 0.827
10 0.394
6 0.236
Fiber
R25 mm
R0.984 in
Sleeve
R10 mm
R0.394 in
FD-H20-M1
"0.02 mm
"0.0008 in
gold wire
1m
3,281 ft
"0.02 mm
"0.0008 in
gold wire
1 m R25 mm
3,281 ft R0.984 in
FD-H20-21
2m
6.562 ft
FD-H30-L32
300 C 572 F Glass substrate detection
Fixed-focus reflective type
W19H27D5
W0.748H1.063
D0.197
2m
6.562 ft
Model No.
"0.02 mm
"0.0008 in
gold wire
FD-H35-20S
R25 mm
R0.984 in
FD-H18-L31
2m
6.562 ft
"0.02 mm
"0.0008 in
gold wire
R25 mm
2 m R0.984 in
6.562 ft
FD-H13-FM2
"0.02 mm
"0.0008 in
gold wire
1 m R200 mm
3,281 ft R7.874 in
FD-6V
Notes: 1) The sensing range is specified for white non-glossy paper [400400 mm 15.74815.748 in (FD-H30-L32, FD-H18-L31: glass substrate 5050 mm 1.9691.969 in)] as the object.
Notes: 2) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the infrared
type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can fluctuate.
Notes: 3) The minimum sensing object size is the value for red LED type at maximum sensitivity. Please contact our office for information on the minimum sensing
object size if using amplifiers other than red LED type. Also, note that the corresponding setting distance is different from the rated sensing distance.
The vacuum type fiber must be used with the following products as a set.
FT-J6: Fiber at atmospheric side (one pair set)
FV-BR1: Photo-terminal (one pair set)
Semi-standard fibers (Custom made per order)
The fiber cable length or sleeve length of the standard fibers can be modified at your request. Select the fiber cable length (symbol ) or the sleeve length
(symbol f ) from the table below.
Type
Basic model No.
Standard threaded
FD-FM head (free-cut)
Fiber cable length
(Unit: m ft)
Correlation between sensing
range attenuation coefficient and
fiber cable length
The longer the fiber cable, the
shorter the sensing range.
f Sleeve length
(Unit: cm in)
3 9.843, 4 13.123, 5 16.404,
10 32.808, 15 49.213, 20 65.617
2 6.562 (Note), 3 9.843, 4 13.123, 1 0.394, 2 0.787, 3 1.181, 4 1.575,
With sleeve FD-FM -S f 5 16.404, 10 32.808, 15 49.213, 5 1.969, 6 2.362, 7 2.756, 8 3.150,
9 3.543, 10 3.937, 11 4.331, 12 4.724
20 65.617
Small diameter
threaded head with FD-NFM2-S f
sleeve (free-cut)
1 0.394, 2 0.787, 3 1.181, 4 1.575,
5 1.969, 6 2.362, 7 2.756, 8 3.150,
9 3.543, 10 3.937, 11 4.331, 12 4.724
200C 392F heat-resistant FD-H20-M 2 6.562, 3 9.843
350C 662F heat-resistant FD-H35-M 3 9.843
• FX-CT2
• FX-AT2
(for fixed-length fiber)
0.8
0.6
0.4
0.2
0
Note: The standard fiber has a 2 m 6.562 ft fiber cable length and a 4 cm 1.575 in or 9 cm 3.543 in sleeve length.
Accessories (attached with fibers)
Fiber cutter
Fiber attachment
1.2
1.0
Sensing range
attenuation coefficient
FX-301
FX-302
Digital Setting
350 C 662 F Sleeve 60 mm 2.362 in
"2.8
M6
"0.110 in
FX-303
FZ-10
FX-11A
FX-CH
FX-311
Color Detection Analog Output Manually Set Bank Selection Unit
Shape of fiber head
(mm in)
350 C 662 F Coaxial
M6
Fiber
Selection
FIBER SENSORS
FX-301
• FX-AT3
for "2.2 mm
"0.087 in fiber
(
)
5
10
15
20
16.404 32.808 49.213 65.617
Fiber cable length # (m ft)
• FX-AT4
(for "1 mm "0.039 in fiber)
• FX-AT5
(for "1.3 mm "0.051 in fiber)
• FX-AT6
for "1 mm "0.039 in and "1.3 mm
"0.051 in mixed fiber
(
)
Notes: 1) Fiber cutter is not supplied as accessory along with FT-NB8, FT-N8, FD-N8 and FD-N4. Please order it separately.
Notes: 2) The fiber attachment is not attached with FT-N8/NB8/P80 and FD-N8/P80. The previous FX-AT10 attachment is attached with FD-N4.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
FIBER OPTIONS
Lens (For thru-beam type fiber)
Description
Fiber
Mode
FT-B8
FT-FM2
FT-T80
FT-W8
FT-P80
FT-P60
FT-P81X
FT-H35-M2
FT-H20W-M1
FT-H20W-M2
FT-H20-M1
FX-SV1
Sensing range increases by 15 times or
more.
Expansion
lens for
vacuum
FV-LE1
fiber
(Note 1)
S-D
2,000
2,500
2,500
1,600
2,000
2,500
1,500
2,500
1,500
900
900
1,100
1,000
1,300
1,300
800
1,000
1,100
900
1,100
750
500
500
900
LONG
STD
FAST
S-D
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
1,600 (Note 3)
3,500 (Note 3)
1,600 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
1,600 (Note 3)
3,500 (Note 3)
1,600 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
1,600 (Note 3)
3,000
1,600 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
1,500
1,500
1,600 (Note 3)
3,500 (Note 3)
LONG
STD
FAST
S-D
1,100
1,200
1,200
900
1,200
650
1,200
550
310
310
550
530
600
600
450
600
300
600
280
140
140
280
400
440
440
330
440
200
440
200
100
100
200
186
210
210
160
210
130
200
90
50
50
90
Sensing range (mm) [Lens on both sides] (Note 2)
Mode
LONG
STD
FAST
S-D
Fiber
• Ambient temperature:
940
FT-6V
3,500 (Note 3)
2,700
1,800
40 to 120 C
490
FT-60V
2,800
1,450
1,000
40 to 248 F
Notes: 1) Be careful when installing the thru-beam type fiber equipped with the expansion lens, as the beam envelope becomes narrow and alignment is difficult.
Especially when installing a fiber with many cores (sharp bending fibers and heat-resistant glass fiber) please be sure to use it only after you have adjusted it sufficiently.
Notes: 2) The sensing ranges are the values for red LED type amplifier. Please contact our office for details on sensing ranges for other types of amplifiers.
Notes: 3) The fiber cable length practically limits the sensing range to 3.500 mm 137.795 in long (FT-H20W-M1 and FT-H20-M1: 1,600 mm 62.992 in).
Lens (For reflective type fiber)
Model No.
Designation
Pinpoint
spot lens
Description
Pinpoint spot of "0.5 mm "0.020 in. Enables detection of minute objects or small marks.
• Applicable fibers: FD-WG4, FD-G4
• Distance to focal point: 61 mm 0.236 0.039 in
• Ambient temperature:40 to 70 C 40 to 158 F
FX-MR1
Screw-in
depth
FX-MR2
For reflective type fiber
Zoom lens
Distance to
focal point
The spot diameter is adjustable from "0.7 mm
"0.028 in to "2 mm "0.079 in according to
how much the fiber is screwed in.
• Applicable fibers: FD-WG4, FD-G4
• Ambient temperature:40 to70 C 40 to 158 F
Spot
diameter • Accessory: MS-EX-3 (mounting bracket)
Sensing range (Note 1)
Extremely fine spot of "0.3 mm "0.012 in approx.
achieved.
• Applicable fibers: FD-WG4, FD-G4, FD-EG1,FD-EG2,
FD-EG3, FD-G6X, FD-G6
• Ambient temperature:40 to 70 C 40 to 158 F
Sensing range (Note 1)
Extremely fine spot of "0.1 mm "0.004 in approx.
achieved.
• Applicable fibers: FD-WG4, FD-G4, FD-EG1,FD-EG2,
FD-EG3, FD-G6X, FD-G6
• Ambient temperature:20 to 60 C 4 to 140 F
Sensing range (Note 1)
Finest spot
FX-MR3
lens
Distance to
focal point
Finest spot
FX-MR6
lens
Spot diameter
Screw-in depth
Zoom lens
Side-view
type
(
)
FX-MR5
Distance
to focal
point
Spot diameter
FX-MR2 is converted into a side-view type and
can be mounted in a very small space.
• Applicable fibers: FD-WG4, FD-G4
• Ambient temperature:40 to 70 C 40 to 158 F
Screw-in depth Distance to focal point
"18.5 mm approx.
7 mm
"27 mm approx.
12 mm
"43 mm approx.
14 mm
Fiber
Distance to focal point
FD-EG3
7.5 0.5 mm
FD-EG2
7.5 0.5 mm
FD-EG1
7.5 0.5 mm
FD-WG4/G4/G6X/G6
7.5 0.5 mm
Fiber
Distance to focal point
FD-EG3
7 0.5 mm
FD-EG2
7 0.5 mm
FD-EG1
7 0.5 mm
FD-WG4/G4/G6X/G6
7 0.5 mm
Spot diameter
"0.7 mm
"1.2 mm
"2.0 mm
Spot diameter
"0.15 mm approx.
"0.2 mm approx.
"0.3 mm approx.
"0.5 mm approx.
Spot diameter
"0.1 mm approx.
"0.15 mm approx.
"0.2 mm approx.
"0.4 mm approx.
Sensing range (Note 1)
Screw-in depth Distance to focal point
8 mm
13 mm approx.
10 mm
15 mm approx.
14 mm
30 mm approx.
Spot diameter
"0.5 mm
"0.8 mm
"3.0 mm
Note: The sensing ranges are the values when used in combination with red LED type amplifier. Please contact our office for details on sensing distances for other types of amplifier.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected] 75
FX-301
FAST
Sensing range (mm) [Lens on both sides] (Note 2)
• Ambient temperature:
60 to 300 C
76 to 572 F
Sideview
lens
Mode
FT-B8
FT-FM2
FT-R80
FT-W8
FT-P80
FT-P60
FT-P81X
FT-H35-M2
FT-H20W-M1
FT-H20W-M2
FT-H20-M1
FT-H13-FM2
Beam axis is bent by 90 .
STD
2,500
3,500 (Note 3)
3,500 (Note 3)
2,300
2,900
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
2,000
1,300
1,300
1,600 (Note 3)
Sensing range (mm) [Lens on both sides] (Note 2)
Fiber
• Ambient temperature:
60 to 350 C
76 to 662 F
LONG
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
3,500 (Note 3)
1,600 (Note 3)
2,600
1,600 (Note 3)
FX-303
For thru-beam type fiber
Tremendously increases the sensing
range with large diameter lenses.
Superexpansion
FX-LE2
lens
(Note 1)
Mode
FT-B8
FT-FM2
FT-T80
FT-R80
FT-W8
FT-P80
FT-P60
FT-P81X
FT-H35-M2
FT-H20W-M1
FT-H20W-M2
FT-H20-M1
Fiber
Selection
Fiber
• Ambient temperature:
60 to 350 C
76 to 662 F
Expansion
lens
FX-LE1
(Note 1)
Sensing range (mm) [Lens on both sides] (Note 2)
Digital Setting
FX-302
Increases the sensing range by 5 times or
more.
Color Detection Analog Output Manually Set Bank Selection Unit
FX-311
FX-11A
FX-CH
FZ-10
Designation Model No.
FIBER SENSORS
FX-301
FIBER OPTIONS
Others
Protective tube
Model No.
FTP-500 (0.5 m 1.640 ft)
FTP-1000 (1 m 3.281 ft)
Protective tube
For thru-beam
type fiber
(
)
FX-301
Fiber
Selection
Designation
FTP-1500 (1.5 m 4.921 ft)
For
FTP-N1000 (1 m 3.281 ft) M3
thread
FTP-N1500 (1.5 m 4.921 ft)
FX-303
FX-302
Digital Setting
FDP-1000 (1 m 3.281 ft)
Protective tube
For reflective
type fiber
(
)
FDP-1500 (1.5 m 4.921 ft)
FDP-N500 (0.5 m 1.640 ft)
For
M6
thread
For
FDP-N1000 (1 m 3.281 ft) M4
FDP-N1500 (1.5 m 4.921 ft)
Fiber bender
FB-1
Universal sensor
mounting stand
(Note 2)
MS-AJ1-F
thread
FT-B8
FT-FM2
FT-FM2S
FT-FM2S4
FT-P80
FT-P60
FT-H13-FM2
FT-T80
FT-NFM2
FT-NFM2S
FT-NFM2S4
FT-P40
FD-T40
FD-P40
FD-B8
FD-FM2
FD-FM2S
FD-FM2S4
FD-P80
FD-H13-FM2
Fiber bender
• FB-1
The protective
tube, made of
non-corrosive
stainless steel,
protects the
inner fiber cable
from any
external forces.
Universal sensor mounting stand
• MS-AJ1-F
• MS-AJ2-F
Using the arm which enables adjustment
in the horizontal direction, sensing can
also be done from above an assembly line.
FD-T80
FD-N4
FD-NFM2
FD-NFM2S
FD-NFM2S4
360 rotation
The fiber bender bends the sleeve part of the fiber head at the
proper radius. (Note 1)
MS-AJ2-F
Horizontal mounting type Mounting stand assembly for fiber
(For M3, M4 or M6 threaded head fiber)
Vertical mounting type
FX-CT1
The free-cut type fiber can be easily cut.
(Accessory for FT/FD-P80 only)
FX-CT2
The free-cut type fiber can be easily cut.
Accessory for the free-cut type fiber. Not attached with the
FT-N8/NB8/P80 and FD-N8/N4/P80
FX-AT2
This is the attachment for the fixed length fiber. (Accessory)
Fiber cutter
FZ-10
FX-11A
FX-CH
FX-311
Color Detection Analog Output Manually Set Bank Selection Unit
For
M4
thread
FTP-N500 (0.5 m 1.640 ft)
FDP-500 (0.5 m 1.640 ft)
• FTP-
• FDP-
Description
Applicable fibers
FIBER SENSORS
FX-301
(
)
360 rotation
20 20 Angle adjustment:20°
Height
adjustment:
150 mm
5.906 in
approx.
Mounting hole
for M6 screw
Mounting base (Note)
Attachment for fixedlength fiber
Attachment for "2.2 mm
FX-AT3
"0.087 in fiber
This is the attachment for the "2.2 mm "0.087 in fiber.
(Accessory. Does not attach with the FT-N8/NB8/P80 or the FD-N8/P80.)
(Note 3)
Attachment for "1 mm
FX-AT4
"0.039 in fiber
This is the attachment for the "1 mm "0.039 in fiber
(Accessory. Does not attach with the FD-N4.) (Note 3)
Attachment for "1.3 mm
FX-AT5
"0.051 in fiber
This is the attachment for the "1.3 mm "0.051 in fiber (Accessory)
Attachment for "1 mm
"0.039 in / "1.3 mm
FX-AT6
"0.051 in mixed fiber
This is the attachment for the "1 mm"0.039 in / "1.3 mm
"0.051 in mixed fiber. (Accessory)
Notes: 1) Do not bend the sleeve part of any side-view type fiber or ultra-small diameter head type fiber.
Notes: 2) Refer to p.332l for details of the universal sensor mounting stand.
Notes: 3) The conventional FX-AT10 fiber attachment is attached with the FD-N4.
Note: The above figure is MS-AJ1-F.
The mounting base of MS-AJ2-F
has a different shape.
Fiber cutter
• FX-CT2
• FX-CT1
Fiber attachment
It’s possible to simultaneously cut two fibers to the same length
Each fiber (with some exceptions) has a newly developed two-in-one fiber attachment (FX-AT3/AT4/AT5/AT6) which enables two fibers to be cut simultaneously
to the same length with the new fiber cutter (FX-CT2). Also, since the fibers can be attached to the amplifier while being fixed in position in the two-in-one fiber
attachment, sensitivity changes resulting from variation in the amount of fiber insertion do not occur.
FX-AT2
FX-AT3
FX-AT4/AT5/AT6
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
SPECIFICATIONS
Amplifiers
FX-301B
FX-301G
FX-301H
<Red LED / Infrared LED type>
(
(
(
Utilization category
FX-301P
FX-301BP
FX-301GP
)
)
)
Normal operation: 720 mW or less
Current consumption 30 mA or less at
24 V supply voltage
ECO mode: 430 mW or less
Current consumption 18 mA or less at 24 V
supply voltage
(
(
PNP open-collector transistor
• Maximum source current: 100 mA
50 mA, if five, or more, amplifiers
are connected in cascade.
• Applied voltage: 30 V DC or less (between output and V)
• Residual voltage: 1.5 V or less
at 100 mA (at 50 mA, if five, or more,
amplifiers are connected in cascade)
source current.
(
150 !s or less (FAST), 250 !s or less [STD / S-D (Red LED type only)], 2 ms or less (LONG) selectable with jog switch
2-level teaching / Limit teaching / Manual adjustment / Full auto-teaching (excluding red LED type)
Operation indicator
Green LED (lights up under stable light received condition or stable dark condition)
MODE indicator
RUN: Green LED, TEACH ADJ L/D ON TIMER PRO: Yellow LED
Digital display
4 digit red LED display
Fine sensitivity adjustment function
Incorporated
Incorporated with variable ON-delay / OFF-delay / ONE SHOT timer, switchable either effective or ineffective. (timer period: 0.5 to 500 ms approx.)
Automatic interference prevention function
Incorporated (Up to four sets of fiber heads can be mounted close together) (Note 1)
3 (Industrial environment)
Pollution degree
10 to 55 °C 14 to 131 °F
7 units are connected in cascade: 10 to 50 °C 14 to 122 °F,
(Ifif 84 toto 16
units are connected in cascade: 10 to 45 °C 14 to 113 °F )
Environmental resistance
Ambient temperature
(No dew condensation or icing allowed),
Storage: 20 to 70 °C 4 to 158 °F
Ambient humidity
35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance
Sunlight: 10,000?x at the light-receiving face, Incandescent light: 3,000?x at the light-receiving face
Red LED type: EN 50081-2, EN 50082-2, EN 60947-5-2
Blue / green / infrared LED type: EN 60947-5-2
EMC
Voltage withstandability
1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 2)
Insulation resistance
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 2)
Vibration resistance
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
Shock resistance
Connecting method
Cable extension
Weight
)
Orange LED (lights up when the output is ON)
Stability indicator
Material
)
FX-303
Incorporated
Sensitivity setting
Emitting element (modulated)
)
Selectable either Light-ON or Dark-ON, with jog switch
Short-circuit protection
Timer function
FX-301HP
DC-12 or DC-13
Output operation
Response time
Green LED Infrared LED
<Blue LED / Green LED type>
Normal operation: 960 mW or less
Current consumption 40 mA or less at
24 V supply voltage
ECO mode: 600 mW or less
Current consumption 25 mA or less at 24 V
supply voltage
NPN open-collector transistor
• Maximum sink current:100 mA
50 mA, if five, or more, amplifiers
are connected in cascade.
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less
at 100 mA (at 50 mA, if five, or more,
amplifiers are connected in cascade)
sink current.
Output
Blue LED
12 to 24 V DC10 % Ripple P-P 10 % or less
Supply voltage
Power consumption
Red LED
FX-301
FX-301
PNP output
Green LED Infrared LED
Fiber
Selection
Model No.
Blue LED
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each
Red LED
Blue LED
Green LED
Infrared LED
Red LED
Blue LED
Green LED
Infrared LED
Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, Switch: Acrylic
Connector (Note 3)
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
25 g approx.
Notes: 1) When the power supply is switched on, the emission timing are automatically set for interference prevention.
Notes: 2) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.
Notes: 3) The cable for amplifier connection is not supplied as an accessory. Make sure to use the optional quick-connection cable given below.
Main cable (3-core): CN-73-C1 (cable length 1 m 3.281 ft), CN-73-C2 (cable length 2 m 6.562 ft), CN-73-C5 (cable length 5 m 16.404 ft)
Sub cable (1-core): CN-71-C1 (cable length 1 m 3.281 ft), CN-71-C2 (cable length 2 m 6.562 ft), CN-71-C5 (cable length 5 m 16.404 ft)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected] 77
Color Detection Analog Output Manually Set Bank Selection Unit
FX-311
FX-11A
FX-CH
FZ-10
Item
Red LED
Digital Setting
FX-302
NPN output
Type
FIBER SENSORS
FX-301
FIBER SENSORS
FX-301
SPECIFICATIONS
Fibers
Item
Type
Fiber
Selection
Allowable bending radius
Standard
R25 mm R0.984 in or more [Sleeve of a head with sleeve:R10 mm R0.394 in or more (Note 1)]
(
Ambient temperature
40 to 70 °C 40 to 158 °F
FT-SFM2SV2: 20 to 70 °C 4 to 158 °F
FT-V22, FD-SFM2SV2: 20 to 60 °C 4 to 140 °F
FT-V41, FD-V41, FT-V10: 40 to 60 °C 40 to 140 °F
40 to 70 °C 40 to 158 °F
)
FT-Z8
, FT-P60, FT-PS1, FD-P60, FD-P50:
(
)
40 to 60 °C 40 to 140 °F
35 to 85%RH (No dew condensation or icing allowed)
Acrylic
Fiber core
Vinyl chloride (FT-PS1: Polyethylene, FD-P2: Vinyl chloride and Polyurethane)
Fiber head
Brass (Nickel plated)
FT-SFM2L/T80/SFM2/SNFM2/SFM2SV2/V22/V41,
FD-T80/T40/S80/SNFM2/SFM2SV2/V41 and Sleeve: Stainless steel (SUS)
FT-FM10L: ABS, Lens of FT-FM10L/SFM2L/V10: Acrylic
FT-V10: Stainless steel (SUS) and Polycarbonate
Stainless steel (SUS)
FT/FD-P80, FT-P60: Brass (Nickel plated)
Case of FT-Z8
: Polycarbonate
Lens of FT-Z8H/Z8E, Front film of FT-Z8: Polyester
Accessories (Note 2)
All fibers (except for FT-NB8/N8 and FD-N8/N4): 1 fiber attachment set
Free-cut type fibers (except for FT-NB8/N8 and FD-N8/N4): FX-CT2 (fiber cutter) 1 pc.
Threaded head fibers: Nuts 2 pcs. (thru-beam type: 4 pcs.) and toothed lock washer
1 pc. (thru-beam type: 2 pcs.)
All fibers: 1 fiber attachment set. (except for FT-P80 and FD-P80)
Free-cut type fibers: FX-CT2 (fiber cutter) 1 pc. (FT/FD-P80: FX-CT1 1 pc.)
Threaded head fibers: Nuts 2 pcs. (thru-beam type: 4 pcs.) and toothed lock
washer 1 pc. (thru-beam type: 2 pcs.), FT-Z8
: 1 set of mounting screw
Material
Polyethylene (FT-V22: Polyolefin)
Sheath
Notes: 1) Sleeve part of side-view fiber cannot be bent.
Notes: 2) The five types of attached fiber attachments (FX-AT2/AT3/AT4/AT5/AT6) described in this catalog are for use only with the FX-301/302/303/311 series.
Refer to p.76 for details ‘FIBER OPTIONS’. Fiber attachment accessories are also supplied along with conventional amplifiers. Please contact our
office for more details on these accessories.
Item
Type
Sharp bending
Allowable bending radius
R1 mm R0.039 in or more (FD-WG4/WSG4: R2 mm R0.079 in or more, Sleeve of FD-W44: R10 mm R0.394 in or more)
40 to 60 °C 40 to 140 °F (FT-WA30/WA8/WKV8: 40 to 55 °C 40 to 131 °F)
Ambient temperature
35 to 85 %RH (No dew condensation or icing allowed)
Ambient humidity
Acrylic
Fiber core
Polyethylene
Material
Sheath
(
Fiber head
Stainless steel (SUS) (including sleeve)
FT-W8/W4, FD-W8/W44/WG4: Brass (Nickel plated)
Case of FT-WA30/WA8/WZ8
, Lens of FT-WS8L and Resin part of FT-WKV8: Polycarbonate, Lens of FT-WA30: Norbornene resin
Lens of FT-WA8: Polyolefin, Lens of FT-WZ8H/WZ8E, Reflector of FT-WZ8E and Prism of FT-WKV8: Acrylic,
Reflector of FT-WZ8: Polycarbonate, FD-WL41: Heat-resistant ABS, Front film of FD-WL41: Polyester,
FD-WL42: Aluminum (Black ALMITE), Lens of FD-WKZ1: Optical lens
)
All fibers: 1 fiber attachment set and FX-CT2 (fiber cutter) 1 pc.
Threaded fibers: Nuts 2 pcs. (thru-beam type: 4 pcs.) and toothed lock washer 1 pc. (thru-beam type: 2 pcs.)
FT-WA30: 0.532 mm 0.0201.260 in seal type slit mask 2 pcs.
FT-WA8: 0.512 mm 0.0200.472 in seal type slit mask 2 pcs. and 112 mm 0.0390.472 in seal type slit mask 2 pcs.
FT-WZ8
: 1 set of mounting screw
FD-WKZ1: mounting bracket 1 pc.
Accessories (Note)
Note: The five types of attached fiber attachments (FX-AT2/AT3/AT4/AT5/AT6) described in this catalog are for use only with the FX-301/302/303/311 series. Refer to p.76 for details
‘FIBER OPTIONS’. Fiber attachment accessories are also supplied along with conventional amplifiers. Please contact our office for more details on these accessories.
Type
Special use
Item
Wide beam
Array
Allowable bending radius
FT-A30/A8: R10 mm R0.394 in or more
FD-A15: R25 mm R0.984 in or more
Ambient temperature
FT-A30, FD-A15: 40 to 60 °C 40 to 140 °F
FT-A8: 40 to 70 °C 40 to 158 °F
Ambient humidity
Accessories (Note)
High precision
R25 mm R0.984 in or more FD-EG2/EG3: R10 mm R0.394 in or more
(FT-KV1: R10 mm R0.394 in or more) FD-G4/G6/EG1: R25 mm R0.984 in or more
40 to 70 °C
40 to 158 °F
40 to 60 °C
40 to 140 °F
(
20 to 60°C 4 to 140 °F
FD-G4: 40 to 70 °C 40 to 158 °F
FD-G6: 40 to 60 °C 40 to 140 °F
)
35 to 85 %RH (No dew condensation or icing allowed)
Acrylic
Sheath
Fiber head
Narrow beam
R25 mm R0.984 in or more
Fiber core
Material
FX-301
FX-302
Digital Setting
FX-303
R4 mm R0.157 in or more
1 million times or more (at R10 mm R0.394 in, FT-P40/P2 and FD-P40/P2: at R4 mm R0.157 in)
Bending durability
Ambient humidity
FZ-10
FX-11A
FX-CH
FX-311
Color Detection Analog Output Manually Set Bank Selection Unit
Flexible
Polyolefin (FD-G4/G6: Polyethylene)
Polyethylene
(
Polycarbonate
Lens of FT-A30, FD-A15: Norbornene resin
Lens of FT-A8: Polyolefin
)
All fibers: 1 fiber attachment set and
FX-CT2 (fiber cutter) 1 pc.
FT-A30: 0.532 mm 0.0201.260 in
seal type slit mask 2 pcs.
FT-A8: 0.512 mm 0.0200.472 in
seal type slit mask 2 pcs. and
1 12 mm 0.039 0.472 in
seal type slit mask 2 pcs.
Brass (Nickel plated)
Stainless steel (SUS), Polycarbonate
Brass (Nickel plated)
Lens: Norbornene resin
Lens of FT-KV1: Polycarbonate, Prism of FT-KV8: Acrylic [FD-G6: Stainless steel (SUS)]
(
)
All fibers: 1 fiber attachment set
Free-cut type fibers: FX-CT2 (fiber cutter) 1 pc.
Threaded head fibers: Nuts 2 pcs. and toothed lock washer 1 pc.
Note: The five types of attached fiber attachments (FX-AT2/AT3/AT4/AT5/AT6) described in this catalog are for use only with the FX-301/302/303/311 series. Refer to p.76 for details
‘FIBER OPTIONS’. Fiber attachment accessories are also supplied along with conventional amplifiers. Please contact our office for more details on these accessories.
78 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Fibers
Type
Item
Special use
Fixed-focus reflective
Ultra-small diameter
Tough flexible
Allowable bending radius
FT-E12/E22: R5 mm R0.197 in or more (Note 1)
FD-E12: R10 mm R0.394 in or more (Note 1)
FD-E22/EN500S1/ENM1S1: R25 mm R0.984 in or more (Note 1)
Ambient temperature
FT-E12/E22, FD-E22: 40 to 70 °C 40 to 158 °F FD-L43: 0 to 70 °C 32 to 158 °F
40 to 60 °C 40 to 140 °F
FD-E12: 40 to 60 °C 40 to 140 °F FD-L41/L42: 40 to 60 °C 40 to 140 °F
(FD-P81X: 40 to 70 °C 40 to 158 °F)
FD-EN500S1/ENM1S1: 20 to 60 °C 4 to 140 °F FD-L4: 40 to 70 °C 40 to 158 °F
R10 mm R0.394 in or more
(FD-L43: R4 mm R0.157 in or more)
35 to 85 %RH (No dew condensation or icing allowed)
Ambient humidity
Polyethylene (FD-L42: Vinyl chloride)
Polyethylene [FT-P81X: Vinyl chloride,
Protective tube: Stainless steel (SUS)]
Brass (Nickel plated)
[Sleeve: Stainless steel (SUS)]
FD-L43/L41: Heat-resistant ABS
FD-L4: ABS
FD-L42: Aluminum (Black ALMITE)
Lens of FD-L43/L4: Acrylic
Front film of FD-L41: Polyester
FT-P81X, FD-P81X: Brass (Nickel plated)
FD-G6X: Stainless steel (SUS)
(
)
All fibers: 1 fiber attachment set and
All fibers: 1 fiber attachment set
FX-CT2 (fiber cutter) 1 pc.
Threaded head fibers: Nuts 2 pcs. and
FD-L4: M2.6 (length 12 mm 0.472 in)
toothed lock washer 1 pc.
screws with washers 2 pcs. and nuts 2 pcs.
Accessories (Note 2)
All fibers: 1 fiber attachment set , nuts 2
pcs. (thru-beam type: 4 pcs.) and toothed
lock washer 1 pc. (thru-beam type: 2 pcs.)
FD-G6X: FX-CT2 (fiber cutter) 1 pc.
Special use
Liquid level sensing
Type
Item
Model No.
Allowable bending radius
Ambient temperature
FD-F8Y
FD-F4
/F9
Protective tube: R40 mm R1.575 in or more
Fiber: R15 mm R0.591 in or more
R10 mm R0.394 in or more
40 to 125 °C 40 to 257 °F (Note 1)
40 to 100 °C 40 to 212 °F (Note 1)
35 to 85 %RH (No dew condensation or icing allowed)
Ambient humidity
Material
FX-303
Notes: 1) Sleeve part cannot be bent.
Notes: 2) The five types of attached fiber attachments (FX-AT2/AT3/AT4/AT5/AT6) described in this catalog are for use only with the FX-301/302/303/311 series. Refer to p.76 for
details ‘FIBER OPTIONS’. Fiber attachment accessories are also supplied along with conventional amplifiers. Please contact our office for more details on these accessories.
Polycarbonate
Fiber core
Sheath
Polyethylene
Polypropylene
(Protective tube: Fluorine resin)
Fiber head
Polyetherimide
(Lens: Polycarbonate)
1 fiber attachment set, FX-CT2 (fiber cutter) 1pc.
Tying bands 4 pcs., anti-slip tubes 2 pcs.
1 fiber attachment set
FX-CT2 (fiber cutter) 1 pc.
Accessories (Note 2)
Notes: 1) With the liquid sensing fiber, make sure that the temperature of the liquid is also within the ambient temperature range.
Notes: 2) The five types of attached fiber attachments (FX-AT2/AT3/AT4/AT5/AT6) described in this catalog are for use only with the FX-301/302/303/311 series. Refer to p.76 for
details ‘FIBER OPTIONS’. Fiber attachment accessories are also supplied along with conventional amplifiers. Please contact our office for more details on these accessories.
Type
Item
Environment resistant
Heat-resistant
Chemical-resistant
350 °C 662 °F type 300°C 572°F type 200°C 392°F type 180°C 356°F type 130°C 266°F type
Vacuum
Allowable bending radius
R30 mm R1.181 in or more R200 mm R7.874 in or more
R25 mm R0.984 in or more
(FT-H20W-
: R10 mm R0.394 in or more, Sleeve of a head with sleeve: R10 mm R0.394 in or more) (FT-Z802Y: R25 mm R0.984 in or more) (FT-60V: R30 mm R1.181 in or more)
Ambient temperature
60 to 350 °C 60 to 300 °C 60 to 200 °C 60 to 180 °C 60 to 130 °C 40 to 115 °C 40 to 239 °F
76 to 662 °F 76 to 572 °F 76 to 392 °F 76 to 356 °F 76 to 266 °F (FT-Z802Y: 0 to 60 °C 14 to 140 °F)
(Note 1, 2)
(Note 1, 2, 3) (Note 2)
(Note 2, 4)
Material
Fiber core
Multi-component glass (Note 3)
Sheath
Stainless steel (SUS)
Fiber head
Accessories (Note 5)
40 to 120 °C
40 to 248 °F
35 to 85 %RH (No dew condensation or icing allowed)
Ambient humidity
Silicone
Inside stainless steel
(SUS) spiral tube
FD-H20-21:
Stainless steel (sus)
FT-H20W-
:
Fluorine resin
Brass (Nickel plated)
FD-H20-21: Stainless steel (sus)
Silicone
Acrylic
Quartz glass (Note 3)
Fluorine resin
Fluorine resin
Protective tube: Fluorine resin
Sheath: Polypropylene
(Sheath of FT-Z802Y: Fluorine resin)
Stainless steel (SUS) Brass (Nickel plated)
FT-H20W-
, FD-H18-L31 and FT-H13-FM2: 1 fiber attachment set
Free-cut type fibers: FX-CT2 (fiber cutter) 1 pc.
Threaded head fibers: Nuts 2 pcs. (thru-beam type: 4 pcs.) and toothed lock washer 1 pc. (thru-beam type: 2 pcs.)
Digital Setting
FX-302
Fiber head
Polyolefin
Aluminum
Nuts 2 pcs. (thru-beam type: 4
1 fiber attachment set
pcs.) and toothed lock washer
FX-CT2 (fiber cutter) 1 pc.
1 pc. (thru-beam type: 2 pcs.)
Notes: 1) If the fiber is used below 30 °C 22 °F, its maximum resistable temperature drops to 200° C 392 °F. If the side-view lens FX-SV1 is put on the fiber head,
the allowable maximum temperature drops to 300 °C 572 °F. (The ambient temperature range of FX-SV1 is from 60 to 300 °C 76 to 572 °F.)
Notes: 2) The ambient temperature of heat-resistant 350 °C 662 °F type, 300 °C 572 °F type, 200 °C 392 °F type and 180 °C 356 °F type fibers are the value in dry
condition. In humid environment, the ambient temperature differs. (For a high humidity of 85 %RH, the ambient temperature is 0 to 40 °C 14 to 104 °F.)
Notes: 3) If the fiber material is quartz glass or multi-component glass, keep it away from vibration or impact.
Notes: 4) The normal temperature for continuous usage or storage should be 60 to 150 °C 76 to 302 °F.
Notes: 5) The five types of attached fiber attachments (FX-AT2/AT3/AT4/AT5/AT6) described in this catalog are for use only with the FX-301/302/303/311 series. Refer to p.76 for
details ‘FIBER OPTIONS’. Fiber attachment accessories are also supplied along with conventional amplifiers. Please contact our office for more details on these accessories.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected] 79
Color Detection Analog Output Manually Set Bank Selection Unit
FX-311
FX-11A
FX-CH
FZ-10
Sheath
FX-301
Acrylic
Fiber core
Material
R10 mm R0.394 in or more
FIBER SENSORS
SPECIFICATIONS
Fiber
Selection
FX-301
FIBER SENSORS
FX-301
I/O CIRCUIT AND WIRING DIAGRAMS
NPN output type
FX-302
Digital Setting
FX-301
Wiring diagram
Color code of quick-connection cable
Color code of quick-connection cable
(Brown) V (Note 1)
D
Sensor circuit
Fiber
Selection
I/O circuit diagram
Load
(Black) Output
Tr
ZD
100 mA max. (Note 2)
Brown (Note)
Load
Black
12 to 24 V DC
10 %
Note: The quick-connection sub cable does not have brown lead wire
and blue lead wire.
Users’ circuit
Notes: 1) The quick-connection sub cable does not have V (brown) and 0 V (blue).
Notes: 2) 50 mA max., if five amplifiers, or more, are connected together.
Terminal arrangement diagram
V
Symbols … D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr : NPN output transistor
Output
0V
PNP output type
FX-303
I/O circuit diagram
Wiring diagram
Color code of quick-connection cable
Color code of quick-connection cable
(Brown) V (Note 1)
Sensor circuit
FZ-10
FX-11A
FX-CH
FX-311
Color Detection Analog Output Manually Set Bank Selection Unit
12 to 24 V DC
10 %
Blue (Note)
(Blue) 0 V (Note 1)
Internal circuit
+
−
ZD
Tr
100 mA max. (Note 2)
(Black) Output
D
Internal circuit
Brown (Note)
Load
(Blue) 0 V (Note 1)
Users’ circuit
Notes: 1) The quick-connection sub cable does not have V (brown) and 0 V (blue).
Notes: 2) 50 mA max., if five amplifiers, or more, are connected together.
Symbols … D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr : PNP output transistor
Black
12 to 24 V DC
10 %
Load
+
−
12 to 24 V DC
10 %
Blue (Note)
Note: The quick-connection sub cable does not have brown lead wire
and blue lead wire.
Terminal arrangement diagram
V
Output
0V
80 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement