5100-EX Owner’s Guide
LEVEL 3 EMI/RFI Noise Filtration with Isolation Between Outlet Banks:
Your audio/video components are constantly being bombarded by electromagnetic interference (EMI) and radio frequency interference
(RFI) through their power cords. This contaminated power can affect audio/video equipment and will degrade the overall performance of your entire system. Common symptoms of contaminated power include pops, hisses, hums and visual artifacts.
The MAX 5100-EX is designed to filter this noise, supply clean power to your system and provide noise isolation between the outlet banks so that any noise created by an A/V component can not contaminate the power going to equipment plugged into the other outlet banks.
Model: M5100-EX
M5100-EX
BANK 1
ALWAYS ON
BANK 2
ON
BANK 3
ON
POWER AND
FILTRATION
WIRING
OK INDICATOR
LIGHTS
90V 95V 100V 105V 110V 115V 120V
125V 130V 135V
Home Theater Power Conditioner
Key Features
Sequential Startup/Shutdown:
Complex audio/video systems may be susceptible to voltage transients generated internally at start-up/shutdown if all of the equipment is powered on or off at the same time. This can cause speaker “thumps” which are not only annoying but can also damage the speakers.
The MAX® 5100-EX is designed to eliminate these transients by providing a “start-up” delay for the High-Current outlets and a “shutdown” delay for the Switched Outlet Bank. This allows the components plugged into the Switched
Outlet Bank to power-up and stabilize before any amplifiers and powered sub-woofers are turned on. This sequence is reversed during shutdown. The amplifiers and powered subwoofers turn off, their power supplies drain, and then the equipment plugged into the
Switched Outlet Bank is turned off.
Voltage Sense Trigger:
This feature provides an ON/OFF trigger for the
MAX® 5100-EX using a Direct Current voltage signal. Many components such as pre-amplifiers and receivers have a DC trigger built in, and will transmit a constant power signal when turned on and in use. The presence of this power signal will turn on the MAX® 5100-EX’s switched outlets. When the source component is turned off, the voltage trigger signal is also turned off and the MAX ® 5100-EX’s shutdown sequence is initiated. An AC Adapter of the appropriate voltage, plugged into a switched outlet, may also be used if a DC trigger is not built in.
The MAX® 5100-EX voltage sense trigger input uses a standard 3.5mm (1/8") mini-plug jack.
This jack has an electrically isolated switch built in. If nothing is inserted into the input jack, the voltage sense is bypassed and the Power
Button on the front panel has sole control of the startup/shutdown sequence. If a plug is inserted into the input jack, the front panel switch is bypassed and the voltage sense becomes the startup/shutdown trigger. IMPORTANT, Please
Note: The unit needs to be plugged in, and in the powered OFF state before inserting the DC input trigger mini-plug.
Automatic Over & Under Voltage Protection:
Panamax’s patent pending power monitoring circuitry constantly monitors the AC line voltage for unsafe voltage conditions such as prolonged over-voltages and under-voltages
(brownouts). These unsafe conditions pose a very dangerous threat to all electronic equipment within the home. If the MAX® 5100-EX senses an unsafe power condition, it will automatically disconnect your equipment from the power to protect equipment from damage.
Once the voltage returns to a safe level, the
MAX® 5100-EX will automatically reconnect the power.
Protect or Disconnect AC Surge Protection:
When the MAX® 5100-EX is subjected to a high voltage surge, its voltage output is limited to a safe level and the high levels of surge current are diverted away from the connected equipment.
• When subjected to a 6,000V (open circuit voltage) / 500A (short circuit current) surge, the MAX® 5100-EX limits its voltage output to less than 330V peak, UL’s best rating. The
MAX® 5100-EX will withstand, without damage, 20,000A surges, far exceeding the UL requirement of only 3000 Ampere surges.
• If the magnitude of the surge is greater than the capacity of the surge protection components, the MAX® 5100-EX's Protect or
Disconnect‘ Circuitry will disconnect your equipment in order to protect it. The MAX®
5100-EX will need to be repaired or replaced by
Panamax if this occurs.
Application Specific Coaxial Signal Line
Protection:
Panamax's exclusive SignalPerfect™ Technology provides application specific protection for your satellite and cable TV equipment. One line of protection is provided for each type. The satellite connection is for a coaxial cable connected to a DBS (single LNB) satellite dish. The antenna connection is for a non-amplified offair antenna or cable TV line.
The protection circuitry has been optimized for each application and is not interchangeable.
The jacks are not labeled In and Out. The circuitry is bidirectional in both signal transmission and protection capabilities, making it compatible with the latest digital cable and satellite technologies.
Cable TV (Including HDTV) – TV tuners operate at approximately 10 millivolts (0.01 V) and utilize the frequency spectrum up to 950 MHz.
The clamping level of the MAX® 5100-EX's cable TV protection circuitry is 1400 millivolts
(1.4 volts). That's less than 1 volt above normal operating levels. The circuitry is also shielded to prevent interference.
Satellite TV - Satellite dish LNB's can require up to 24 volts to operate and utilize the frequency range of 950 MHz to 2.2 GHz. The clamping level of the MAX® 5100-EX's satellite protection circuitry is 25 volts - just 1 volt above the maximum operating voltage. The circuitry is also shielded to prevent interference.
Telephone Line Protection:
Digital video recorders and satellite TV receivers require a telephone line connection for TV show scheduling and/or Pay-Per-View services. The MAX® 5100-EX also provides surge protection for this line. One pair of RJ-
11 telephone jacks is provided for this. The circuitry utilizes auto-resetting PTCRs and solidstate SIDACtors“ for reliability and unsurpassed protection. The clamping level of the
MAX 5100-EX's telephone protector is 260 volts. This will allow typical ring voltage (90-
130VAC) and operating battery voltage (-48DC) to pass through the circuit and still protect the modem in your satellite receiver from damage.
INS0785E Rev A 5/05
M5100 -EX Front Panel Features
Power Button
Press and hold for 2 seconds to turn Bank 2 and
Bank 3 outlets ON or OFF.
This switch is bypassed if the rear panel DC Trigger input is being used.
Power LEDs
Indicates the status of the rear panel outlets. LEDs for each outlet bank will be lit when the outlets are turned
ON. They will flash during the startup and shutdown process.
Wiring OK LED
Normally On. Indicates that the wall outlet is properly grounded and
Line/Neutral polarity is correct.
Meter Dimmer
Pushbutton control for meter LED brightness.
Cycles between Off,
Low, Medium and High.
Voltmeter
Ten segment LED voltmeter indicates voltages between 90–135VAC. If line voltage drops below 90VAC, the first LED will flash slowly to indicate an under-voltage condition. If line voltage exceeds
145VAC, the first 9 LED’s turn off and the last LED (Red) will flash slowly to indicate an over voltage condition
M5100-EX
BANK 1
ALWAYS ON
BANK 2
ON
POWER AND FILTRATION
BANK 3
ON
WIRING
OK
METER
LIGHTS 90V 95V 100V 105V 110V 115V 120V 125V 130V 135V
Home Theater Power Conditioner
Convenience
Outlet
Provides a quick convenient way to plug in components such as camcorders and video game systems.
M5100 -EX Back Panel Connection Features
Circuit Breaker
Automatically opens when the current load is greater than 15
Amps. Push to reset.
15 AMP CIRCUIT
BREAKER
BANK 3
Outlet Bank 2
Four switched outlets controlled by the front panel Power Button or the DC Trigger input. Bank 2 will turn on immediately and turn off after 10 seconds. EMI/RFI noise filtration is provided by a two-stage balanced
Pi filter which also provides noise isolation from Outlet Banks 1 and 3.
Outlet Bank 1
Four always on outlets. Power will only be turned off under a fault condition. (See specifications for over-voltage and under-voltage thresholds) Power is cleaned by a two-stage balanced Pi filter which also provides noise isolation from Outlet Banks 2 and 3.
BANK 2 BANK 1
GROUND
LUG
MAIN POWER
120 VAC/15A
DELAY ON
ALWAYS ON HIGH CURRENT SWITCHED
SAT
Satellite TV
Coax Jacks
Bidirectional protection circuit optimized for satellite
TV signal lines. Do not use for cable TV off-air antennas and cable modems.
Cable TV Coax Jacks
Bidirectional protection circuit optimized for cable TV, off-air antennas and cable modem signal lines. Do not use for Satellite TV.
CATV / ANT
VOLTAGE SENSE
TRIGGER INPUT
3 - 24VDC
LAN PHONE
LINE IN EQUIP. LINE IN EQUIP.
Main Power
Must be plugged into a properly wired & grounded 3-wire outlet
Ground Lug
Provides a common grounding point for equipment with separate ground leads.
Outlet Bank 3
Two switched, high current outlets controlled by the front panel Power Button or the DC
Trigger input. Bank 3 has a 5 second turn on delay and turns off immediately. The High
Current outlet provides power from a low impedance noise filtration circuit that does not limit the current to your equipment. Its output is noise isolated from all other outlet banks.
Voltage Sense Trigger Input
3.5mm (1/8”) Mini-Plug jack.
Connect to a remote trigger device that uses a DC output to trigger a startup/shutdown sequence. This bypasses the front panel power switch. Important, Please Note:
The unit needs to be plugged in, and in the powered OFF state before inserting the DC input trigger mini-plug.
LAN Jacks
Protection circuits for 10/100 baseT
Ethernet lines.
Incoming LAN line
MUST be plugged into the LINE jack.
Patch cord to the equipment MUST be plugged into the EQUIP jacks.
Phone Jacks
Protection circuits for standard telephone or payper-view lines. Phone circuit is auto-resetting.
Incoming phone cord
MUST be plugged into the
LINE jack. Patch cords to the equipment (satellite receiver, digital video recorder, telephone, etc.)
MUST be plugged into the
EQUIP jacks.
Note to CATV Installers:
This reminder is provided to call attention to Article 820-40 of the NEC. That article provides specific guidelines for proper grounding.It specifies that the cable ground shall be connected to the grounding system of the building and as close to the point of entry as practical.
M5100-EX Specifications
AC Power
Line Voltage:..............................................................................120V, 60Hz
Total Current Capacity:.........................................................................15 A
UL1449 Suppression Rating:..............................................................330V
Protection Modes:.................................................................L-N, L-G, N-G
Initial Clamping Level:.........................................................................200V
Energy Dissipation:..................................................................1815 Joules
Peak Impulse Current:............................................................73,000 Amps
Catastrophic Surge Circuit:....................................................................Yes
Thermal Fusing:.....................................................................................Yes
Over-voltage shutoff:.........................................................142 VAC ±5 VAC
Under-voltage shutoff:........................................................90 VAC ±3 VAC
EMI/RFI Noise Filtration
Banks 1 & 2:........................................................80 db, 100 KHz – 2 MHz
Bank 3, High Current Outlets:..............................60 db, 100 KHz – 2 MHz
DC Trigger Input
Jacks:....................................................................3.5mm (1/8”) mini-plug
Voltage and Polarity:.............................................3 - 24V DC, bidirectional
Current Requirement:........................................4.6 mA @3V, 58 mA @24V
LAN Circuit
Clamping Level:..............................................................................8V ± 2V
Jacks:................................................................................................RJ-45
Wires Protected:...................................................4-Wires, Pins 1, 2, 3 & 6
Telephone Circuit
Fuseless/Auto-resetting:........................................................................Yes
Clamping Level:..................................................................................260V
Capacitance:.........................................................................30pf (approx.)
Suppression Modes:...............................................Metallic & Longitudinal
Jacks:................................................................................................RJ-11
Wires Protected:.............................................................2-Wire, Pins 4 & 5
Satellite TV Circuit
Bidirectional:.........................................................................................Yes
Shielded:...............................................................................................Yes
Clamping Level:....................................................................................25V
Attenuation:.................................................< 1db from 950MHz -2.05GHz
< 2.4db @ 2.2GHz
Connections:..........................................................Female “F”, Gold Plated
Cable TV Circuit
Bidirectional:.........................................................................................Yes
Shielded:...............................................................................................Yes
Clamping Level:...................................................................................1.4V
Attenuation:.................................................................< 1db up to 950MHz
Connections:..........................................................Female “F”, Gold Plated
Specifications are subject to changes due to product upgrades and improvements.
Contacting Panamax Contents
Two coaxial cables
One telephone patch cord
Product warranty (see back panel)
Panamax
1690 Corporate Circle
Petaluma, CA 94954
Phone - 707-283-5900 or 800-472-5555
Fax - 707-283-5901
Web - www.panamax.com
Customer Relations
7:30 AM – 4:30 PM, M-F
Email - [email protected]
© 2005 Panamax. Panamax, MAX and the Panamax logo are registered US trademarks of Panamax. Protect or Disconnect and SignalPerfect are trademarks of Panamax.
SIDACtor is a registered US trademark of Teccor Electronics, Inc.
Panamax warrants to the purchaser of this
Panamax audio/video component style power conditioner, for a period of three (3) years from the date of purchase, that the unit shall be free of defects in design, material or workmanship, and Panamax will repair or replace any defective unit. For product replacement see "NOTIFI-
CATION" below.
CAUTION
Audio/Video, computer and/or telephone system installations can be very complex systems, which consist of many interconnected compo-
Panamax Power Conditioner Limited Product Warranty
nents. Due to the nature of electricity and surges, a single protector may not be able to completely protect complex installations. In those cases, a systemic approach using multiple protectors must be employed. Systemic protection requires professional design. AC power, satellite cables, CATV cables, telephone/network lines or any other signal lines entering the system that do not pass through this surge protector may render the Panamax
Connected Equipment Protection Policy null and void. For additional information on how to protect your system, please contact Panamax before connecting your equipment to the surge protector.
WARNING NOTICE
Panamax products purchased through the
Internet do not carry a valid Product Warranty or Connected Equipment Protection Policy unless purchased from an Authorized Panamax
Internet Dealer and the original factory serial numbers are intact (they must not have been removed, defaced or replaced in any way).
Authorized Panamax Internet Dealers have sufficient expertise to insure warranty compliant installations. For a list of Authorized Panamax
Internet Dealers go to www.panamax.com
More detailed information is available at www.panamax.com
If you have any questions regarding these requirements, please contact Panamax
Customer Relations
Panamax Power Conditioner Limited Connected Equipment Protection Warranty
Valid only in the United States and Canada.
It is the policy of Panamax that it will, at its election, either replace, pay to replace at fair market value, or pay to repair, up to the dollar amount specified below, equipment that is damaged by an AC power, cable, telephone, or lightning surge while connected to a properly installed Panamax power conditioner.
Panamax must determine that the power conditioner shows signs of surge damage or is operating outside of design specifications, relative to its surge protection capability, and under all of the circumstances failed to protect your connected equipment.
3. NOTIFICATION: You must notify Panamax within ten days of any event precipitating a request for product replacement or payment for connected equipment damage. A return merchandise authorization (RMA) number must first be obtained from the Panamax Customer
Relations Department at www.panamax.com/
support ** before returning the protector to
Panamax. At this time, you must notify
Panamax if you believe you have a claim for damaged connected equipment.
Panamax reserves the right to inspect the damaged connected equipment, parts, or circuit boards. Please note that you are responsible for any and all charges related to shipping the damaged equipment to Panamax. Panamax also reserves the right to inspect the customer’s facility. Damaged equipment deemed uneconomical to repair must remain available for inspection by Panamax until the claim is finalized.
or controversy between you and Panamax. The arbitration shall be held in any mutually agreed upon location in person, by telephone, or online. Any decision rendered in such arbitration proceedings will be final and binding on each of the parties, and judgment may be entered thereon in a court of competent jurisdiction. The arbitrator shall not award either party special, exemplary, consequential, punitive, incidental or indirect damages, or attorney's fees. The parties will share the costs of arbitration (including the arbitrator's fees, if any) in the proportion that the final award bears to the amount of the initial claim.
M4300-EX: $5,000,000
M5300-EX: $5,000,000
M5510-Pro: $5,000,000
M4310: $5,000,000
M5400-EX: $5,000,000
ML4200: $5,000,000
M4400: $5,000,000
M5410: $5,000,000
M5100-EX: $5,000,000
M5500-EX: $5,000,000
THIS WARRANTY IS SUBJECT TO THE FOLLOW-
ING CONDITIONS:
1. ORIGINAL OWNERSHIP REQUIREMENT:
Panamax’s connected equipment policy extends to the original purchaser of the
Panamax product only and is non-transferable.
Original purchase receipts must accompany any product return or claim for connected equipment damage.
2. PROPER INSTALLATION: Panamax AC protectors must be directly plugged into a properly grounded 3-wire AC outlet. Extension cords*, non-grounded two prong adapters, or other non-Panamax surge products must not be used. Building wiring and other connections to protected equipment must conform to applicable codes (NEC or CEC). No other ground wires or ground connections may be used. All wires (including, e.g., AC power lines, telephone lines, signal/data lines, coaxial cable, antenna lead-ins) leading into the protected equipment must first pass through a single
Panamax protector designed for the particular application. The protector and the equipment to be protected must be indoors in a dry location, and in the same building. Panamax installation instructions and diagrams must be followed.
Once you obtain an RMA number, please mark the number on the bottom of the unit and pack it in a shipping carton/box with enough packing material to protect it during transit. The RMA number must also be clearly marked on the outside of the carton. Ship the unit to
Panamax. Please note that you are responsible for any and all charges related to shipping the unit to Panamax.
If connected equipment damage was indicated on your RMA request, Panamax will mail you a claim kit to be completed and returned within
30 days. A connection diagram of your system will be required as part of the claim kit.
Be sure to note its configuration before disconnecting your equipment.
4. DETERMINATION OF FAILURE: Panamax will evaluate the protector for surge damage. The
Panamax protector must show signs of surge damage or must be performing outside (>10%) of design specifications relative to its surge protection capability. Opening the enclosure, tampering with, or modifying the unit in any way shall be grounds for an automatic denial of your request for payment. Panamax, after evaluating all information provided, shall determine whether or not your request is eligible for payment.
If the surge protector shows no signs of AC power or signal line surge damage and is working within design specifications, Panamax will return the unit to you with a letter explaining the test results and notifying you of the rejection of your claim. Exceptions: If a dealer or installer replaces the protector for the customer, a replacement will be returned to the dealer or installer; or if the protector is a pre-1996 model, it will be replaced; or, for a Canadian customer, the protector will be replaced.
5. REQUEST PAYMENTS: Once Panamax has determined that you are entitled to compensation, Panamax will, at its election, either pay you the present fair market value of the damaged equipment, or pay for the cost of the repair, or send you replacement equipment, or pay the equivalence of replacement equipment.
6. OTHER INSURANCE/WARRANTIES: This coverage is secondary to any existing manufacturer's warranty, implied or expressed, or any insurance and/or service contract that may cover the loss.
7. EXCLUSIONS: THE PANAMAX CONNECTED
EQUIPMENT PROTECTION POLICY DOES NOT
APPLY TO: THE PANAMAX CONNECTED
EQUIPMENT PROTECTION POLICY DOES NOT
APPLY TO: Service charges, installation costs, reinstallation costs; setup cost; diagnostic charges; periodic checkups; routine maintenance; loss of use of the product; costs or expenses arising out of reprogramming or loss of programming and/or data; shipping charges or fees; service calls; loss or damage occasioned by fire, theft, flood, wind, accident, abuse or misuse, and products subject to manufacturer's recall or similar event.
8. DISPUTE RESOLUTION: Any controversy or claim arising out of or relating to Panamax’s
Connected Equipment Protection Policy, or the alleged breach thereof, shall be settled by arbitration administered by the American
Arbitration Association under its Commercial
Arbitration Rules. You may file for arbitration at any AAA location in the United States upon the payment of the applicable filing fee. The arbitration will be conducted before a single arbitrator, and will be limited solely to the dispute
9. GENERAL: If you have any questions regarding the product warranty or the connected equipment protection warranty, please contact the Panamax Customer Relations Department at www.panamax.com/support. This warranty supersedes all previous warranties. THIS IS
THE ONLY WARRANTY PROVIDED WITH THE
PROTECTOR AND ANY OTHER IMPLIED OR
EXPRESSED WARRANTIES ARE NON-EXIS-
TENT. This warranty may not be modified except in writing, signed by an officer of the
Panamax Corporation.
* The use of a Panamax extension cord or equivalent (UL or CSA listed, minimum 14AWG, 3-wire grounded) will not invalidate the warranty
** Forms are available on the Panamax web site for requesting RMAs and opening a claim for connected equipment damage.
Effective Date 06/05 Q01L0049 Rev. A
Product Upgrade Program
Valid only in the United States and Canada
If your Panamax power conditioner sacrifices itself while protecting your connected equipment, you have an option to upgrade to the latest technology. Please go to our web site www.panamax.com/rma or contact Panamax
Customer Relations at 800-472-5555 for details.
www.panamax.com