INSTALLATION INSTRUCTIONS

30" (76.2 CM) FREESTANDING GAS RANGES

with standard clean oven

Table of Contents

RANGE SAFETY ............................................................................. 2

INSTALLATION REQUIREMENTS................................................ 3

Tools and Parts............................................................................ 3

Location Requirements................................................................ 3

Electrical Requirements............................................................... 5

Gas Supply Requirements........................................................... 5

INSTALLATION INSTRUCTIONS.................................................. 7

Unpack Range ............................................................................. 7

Install Anti-Tip Bracket ................................................................ 7

Make Gas Connection ................................................................. 8

Verify Anti-Tip Bracket Location.................................................. 9

Level Range ................................................................................. 9

Electronic Ignition System ......................................................... 10

Complete Installation ................................................................. 11

GAS CONVERSIONS ................................................................... 12

LP Gas Conversion.................................................................... 12

Complete Conversion ................................................................ 14

Natural Gas Conversion............................................................. 14

Complete Conversion ................................................................ 15

IMPORTANT:

Installer: Leave installation instructions with the homeowner.

Homeowner: Keep installation instructions for future reference.

W10032050B

RANGE SAFETY

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”

These words mean:

DANGER

You can be killed or seriously injured if you don't immediately follow instructions.

WARNING

You can be killed or seriously injured if you don't follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

2

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

WARNING: Gas leaks cannot always be detected by smell.

Gas suppliers recommend that you use a gas detector approved by UL or CSA.

For more information, contact your gas supplier.

If a gas leak is detected, follow the “What to do if you smell gas” instructions.

In the State of Massachusetts, the following installation instructions apply:

Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the State of Massachusetts.

If using a ball valve, it shall be a T-handle type.

A flexible gas connector, when used, must not exceed 3 feet.

WARNING

Tip Over Hazard

A child or adult can tip the range and be killed.

Connect anti-tip bracket to rear range foot.

Reconnect the anti-tip bracket, if the range is moved.

Failure to follow these instructions can result in death or serious burns to children and adults.

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation.

Read and follow the instructions provided with any tools listed here.

Tools needed

Level

³⁄₈" drive ratchet

Tape measure

Flat-blade screwdriver

Phillips screwdriver

Hand or electric drill

Wrench or pliers

7 mm combination wrench

Pipe wrench

¹⁄₈" (3.2 mm) drill bit (for wood floors)

³⁄₁₆" (4.8 mm) carbide-tipped masonry drill bit (for concrete/ ceramic floors)

Pipe-joint compound resistant to LP gas

Noncorrosive leak-detection solution

Parts supplied

Check that all parts are included.

A

B

C

A. Anti-tip bracket

B. Plastic anchors (2)

C. #10 x 1

¹⁄₂" screws (2)

Anti-tip bracket must be securely mounted to subfloor.

Thickness of flooring may require longer screws to anchor bracket to subfloor. Longer screws are available from your local hardware store.

Parts needed

Check local codes and consult gas supplier. Check existing gas and electrical supply. See “Electrical Requirements” and “Gas

Supply Requirements” section.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances. Do not obstruct flow of combustion and ventilation air.

It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located on the oven frame behind the left side of the broiler door.

A

A. Model/serial rating plate location

The range should be located for convenient use in the kitchen.

Recessed installations must provide complete enclosure of the sides and rear of the range.

To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets.

All openings in the wall or floor where range is to be installed must be sealed.

Do not seal the range to the side cabinets.

Cabinet opening dimensions that are shown must be used.

Given dimensions are minimum clearances.

The floor anti-tip bracket must be installed. To install the antitip bracket shipped with the range, see “Install Anti-Tip

Bracket” section.

Grounded electrical supply is required. See “Electrical

Requirements” section.

Proper gas supply connection must be available. See “Gas

Supply Requirements” section.

Contact a qualified floor covering installer to check that the floor covering can withstand at least 200°F (93°C).

Use an insulated pad or ¼" (0.64 cm) plywood under range if installing range over carpeting.

IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).

3

Mobile Home - Additional Installation Requirements

The installation of this range must conform to the Manufactured

Home Construction and Safety Standard, Title 24 CFR, Part 3280

(formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home

Installations, ANSI A225.1/NFPA 501A or with local codes.

In Canada, the installation of this range must conform with the current standards CAN/CSA-A240 - latest edition, or with local codes.

Mobile home installations require:

When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above.

Product Dimensions

Cabinet Dimensions

Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and

36" (91.4 cm) countertop height.

If the cabinet depth is greater than 24" (61.0 cm), oven frame must extend beyond cabinet fronts by ½" (13.0 mm) minimum.

IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.

C

B

D

A

E

H

G

A

B

J

I

N

L

M

L

K

C

F

E

D

A. 26¼" (67.9 cm)

B. 36" (91.4 cm)

C. 46¼" (117.5 cm)

D. 29

⁷⁄₈

" (75.9 cm)

E. 24¼" (61.6 cm)

A. 18" (45.7 cm) min. clearance upper side cabinet to countertop

B. 13" (33.0 cm) max. upper cabinet depth

C. 30" (76.2 cm) min. cabinet opening width

D. For minimum clearance to top of cooktop, see NOTE*.

E. 30

¹⁄₈" (76.5 cm) min. opening width

F. This shaded area recommended for installation of electrical outlet.

G. This shaded area recommended for installation of rigid gas pipe.

H. 2" (5.1 cm) min. countertop space to side wall or other combustible material

I. 24" (61.0 cm)

J.

10" (25.4 cm)

K. 8" (20.3 cm)

L. 5" (12.7 cm)

M. 2" (5.1 cm)

N. 3" (7.6 cm)

*NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is covered by not less than

¹⁄₄" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel,

0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or

0.020" (0.5 mm) copper.

30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.

4

Electrical Requirements

WARNING

Gas Supply Requirements

WARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

IMPORTANT: The range must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, latest edition.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this range be provided.

This range is equipped with a power supply cord having a

3 prong ground plug. To minimize possible shock hazard the cord must be plugged into a grounded 3 prong outlet.

Electronic ignition systems operate within wide voltage limits, but proper grounding and polarity are necessary. Check that the outlet provides 120-volt power and is correctly grounded.

This range is equipped with an electronic ignition system that will not operate if plugged into an outlet that is not properly polarized.

The wiring diagram is located on the back of the range in a clear plastic bag.

NOTE: The metal chassis of the range must be grounded in order for the control panel to work. If the metal chassis of the range is not grounded, no keypads will operate. Check with a qualified electrician if you are in doubt as to whether the metal chassis of the range is grounded.

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.

Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

Observe all governing codes and ordinances.

IMPORTANT: This installation must conform with all local codes and ordinances. In the absence of local codes, installation must conform with American National Standard, National Fuel Gas

Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest edition.

IMPORTANT: Leak testing of the range must be conducted according to the manufacturer’s instructions.

Type of Gas

Natural gas:

This range is design-certified by CSA International for use with

Natural gas or, after proper conversion, for use with LP gas.

This range is factory set for use with Natural gas. See “Gas

Conversions” section. The model/serial rating plate located behind the broiler door on the left-hand side oven door frame has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier.

LP gas conversion:

Conversion must be done by a qualified service technician.

No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. See “Gas

Conversions” section.

5

Gas Supply Line

Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. With LP gas, piping or tubing size can be ½" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system.

NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON ®† tape.

Flexible metal appliance connector:

If local codes permit, a new CSA design-certified,

4 to 5 ft (122 to 152.4 cm) long, ½" (1.3 cm) or

¾" (1.9 cm) I.D., flexible metal appliance connector may be used for connecting range to the gas supply line.

A ½" (1.3 cm) male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator.

Do not kink or damage the flexible metal tubing when moving the range.

Rigid pipe connection:

The rigid pipe connection requires a combination of pipe fittings to obtain an in-line connection to the range. The rigid pipe must be level with the range connection. All strains must be removed from the supply and fuel lines so range will be level and in line.

Must include a shutoff valve:

The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the range opening, such as an adjacent cabinet. It should be in a location that allows ease of opening and closing. Do not block access to shutoff valve. The valve is for turning on or shutting off gas to the range.

B

Gas Pressure Regulator

The gas pressure regulator supplied with this range must be used. The inlet pressure to the regulator should be as follows for proper operation:

Natural gas:

Minimum pressure: 5" WCP

Maximum pressure: 14" WCP

LP gas:

Minimum pressure: 11" WCP

Maximum pressure: 14" WCP

Contact local gas supplier if you are not sure about the inlet pressure.

Burner Input Requirements

Input ratings shown on the model/serial rating plate are for elevations up to 2,000 ft (609.6 m).

For elevations above 2,000 ft (609.6 m), ratings are reduced at a rate of 4% for each 1,000 ft (304.8 m) above sea level (not applicable for Canada).

Gas Supply Pressure Testing

Gas supply pressure for testing regulator must be at least

1" water column pressure above the manifold pressure shown on the model/serial rating plate.

Line pressure testing above ½ psi gauge (14" WCP)

The range and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa).

Line pressure testing at ½ psi gauge (14" WCP) or lower

The range must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).

A

C

A. Gas supply line

B. Shutoff valve “open” position

C. To range

†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

6

INSTALLATION INSTRUCTIONS

Unpack Range

WARNING

2. Place template on the floor in cabinet opening so that the left edge is against cabinet and top edge is against rear wall, molding or cabinet.

3. Tape template into place.

4. If countertop is not flush with cabinet opening edge, align template with overhang.

Excessive Weight Hazard

Use two or more people to move and install range.

Failure to do so can result in back or other injury.

1. Do not use oven door handle to lift or move the range

2. Remove shipping materials, tape and film from range. Keep cardboard bottom under range.

3. Remove oven racks and parts package from inside oven.

4. To place range on its back, take 4 cardboard corners from the carton. Stack one cardboard corner on top of another.

Repeat with the other 2 corners. Place them lengthwise on the floor behind the range to support the range when it is laid on its back.

5. Using 2 or more people, firmly grasp the range and gently lay it on its back on the cardboard corners.

6. Pull cardboard bottom firmly to remove.

7. Use an adjustable wrench to loosen the leveling legs. Adjust the leveling legs to the correct height. Leveling legs can be loosened to add up to a maximum of 1" (2.5 cm). A minimum of

³⁄₁₆" (0.5 cm) is needed to engage the anti-tip bracket.

NOTE: If height adjustment is made when range is standing, tilt the range back to adjust the front legs, then tilt forward to adjust the rear legs.

8. Place cardboard or hardboard in front of range. Using 2 or more people, stand range back up onto cardboard or hardboard.

Install Anti-Tip Bracket

WARNING

If cabinet opening is wider than that specified in the “Location

Requirements” section, adjust template so range will be centered in cabinet opening.

5. To mount anti-tip bracket to wood floor, drill two

¹⁄₈" (0.32 cm) holes at the positions marked on the bracket template.

Remove template from floor and move to Step 7.

To mount the anti-tip bracket to a concrete or ceramic floor, use a

³⁄₁₆" (0.5 cm) masonry drill bit to drill 2 holes at the positions marked on the bracket template. Remove the template from the floor. Tap plastic anchors into holes with a hammer.

6. Align the anti-tip bracket holes with the holes in the floor.

Fasten the anti-tip bracket with the screws provided.

Tip Over Hazard

A child or adult can tip the range and be killed.

Connect anti-tip bracket to rear range foot.

Reconnect the anti-tip bracket, if the range is moved.

Failure to follow these instructions can result in death or serious burns to children and adults.

Contact a qualified floor covering installer for the best procedure for drilling mounting holes through your type of floor covering.

Before moving range, slide range onto shipping base, cardboard or hardboard.

1. Remove template from the anti-tip bracket kit (found inside the oven cavity).

Depending on the thickness of your flooring, longer screws may be necessary to anchor the bracket to the subfloor.

Longer screws are available from your local hardware store.

7

8

7. Move range close enough to the opening to allow for final electrical connection. Remove shipping base, cardboard or hardboard from under range.

8. Open the broiler door. Use a

³⁄₈" drive ratchet to lower the rear leveling legs one-half turn. Use a wrench or pliers to lower the front leveling lets one-half turn.

B

Make Gas Connection

WARNING

A

A. Rear leveling leg

B Front leveling leg

A. Rear leveling leg

B. Front leveling leg

9. Adjust the leveling legs to the correct height. Leveling legs can be loosened to add up to a maximum of 1" (2.5 cm). A minimum of

³⁄₁₆" (0.5 cm) is needed to engage the anti-tip bracket.

10. Move range into its final location making sure rear leveling leg slides into anti-tip bracket.

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.

Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

11. If installing the range in a mobile home, you must secure the range to the floor. Any method of securing the range is adequate as long as it conforms to the standards in the

“Location Requirements” section.

12. Continue installing your range using the following installation instructions.

Typical rigid pipe connection

A combination of pipe fittings must be used to connect the range to the existing gas line. Your connections may be different, according to the supply line type, size and location.

1. Apply pipe-joint compound made for use with LP gas to all pipe thread connections.

2. Using a pipe wrench to tighten, connect the gas supply to the range.

B

A

C

D

E

F

G

A. Pressure regulator connection fitting

B. 90° elbow

C. Black iron pipe

D. Union

E. Nipple

F. Manual shutoff valve

G. ½" or ¾" gas pipe

Typical flexible connection

1. Apply pipe-joint compound made for use with LP gas to the smaller thread ends of the flexible connector adapters (see B and F in the following illustration).

2. Attach one adapter to the gas pressure regulator and the other adapter to the gas shutoff valve. Tighten both adapters.

3. Use a combination wrench and pliers to attach the flexible connector to the adapters. Check that connector is not kinked.

A

B

5. Close the broiler door.

6. Remove cooktop burner caps and grates from parts package. Align notches in burner caps with pins in burner base. Burner caps should be level when properly positioned.

If burner caps are not properly positioned, surface burners will not light. Place burners, burner caps and grates on the cooktop.

WARNING

D

C

E

F

G

H

A. Pressure regulator connection fitting

B. Use pipe-joint compound

C. Adapter

D. Flexible connector

E. Adapter

F. Use pipe-joint compound

G. Manual shutoff valve

H. ½" or ¾" gas pipe

Complete Connection

1. Locate gas pressure regulator in the broiler.

A

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

IMPORTANT: Do not remove the gas pressure regulator.

2. Check that the gas pressure regulator shutoff valve is in the

“on” position.

7. Plug into a grounded 3 prong outlet.

Verify Anti-Tip Bracket Location

1. Check that the anti-tip bracket is installed:

Look for the anti-tip bracket securely attached to the floor.

Slide the range back so the rear range foot is under the antitip bracket.

1. Place rack in oven.

Level Range

2. Place level on rack and check levelness of range, first side to side; then front to back.

Front

Side View

Shutoff valve

“ON” Position

3. Open the manual shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe.

A

B

A. Closed valve

B. Open valve

4. Test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak. Correct any leak found.

3. If range is not level, pull range forward until rear leveling leg is removed from the anti-tip bracket. Use

³⁄₈" drive ratchet and wrench or pliers to adjust leveling legs up or down until range is level.

4. Push range back into position.

5. Check that rear leveling leg is engaged in anti-tip bracket.

NOTE: Range must be level for satisfactory baking performance.

9

Electronic Ignition System

Initial lighting and gas flame adjustments

Cooktop and oven burners use electronic igniters in place of standing pilots. When the cooktop control knob is turned to the

“LITE” position, the system creates a spark to light the burner.

This sparking continues until the control knob is turned to the desired setting.

When the oven control is turned to the desired setting, a hot surface igniter heats to a bright orange and ignites the gas. No sparking occurs. The glow bar remains on while the burner operates.

If the low flame needs adjusting:

1. Turn control knob to the “Lo” setting and remove control knob.

2. Insert a small flat-blade screwdriver into the valve stem. Turn the valve adjusting screw to obtain the smallest flame that will not go out when the control of a cold burner is quickly turned from “HI” to “Lo.” Turn right to decrease flame height. Turn left to increase flame height. Repeat for other cooktop burners as needed.

Check Operation of Cooktop Burners

1. If control panel and knobs were removed earlier, reinstall knobs.

2. Push in and turn each surface unit control knob to “LITE” position. The flame should light within 4 seconds.

OFF

A

LITE

HI

MED

3. Turn control knob to “HI” position after burner lights.

4. Check each cooktop burner for proper flame. The small inner cone should have a very distinct blue flame ¼" (0.64 cm) to

½" (0.13 cm) long. The outer cone is not as distinct as the inner cone.

A

B

LO

A. Outer cone

B. Inner cone

5. Turn the control knob quickly to the “LO” position after the burner lights. If the flame goes out, turn the control knob to the “OFF” position.

6. Check each cooktop burner for proper low flame. The low flame should be a minimum, steady blue flame. The flame size should be ¼" to

³⁄₈" (0.64 cm to 0.95 cm) high.

A. Valve stem

3. Replace control knob.

Check Operation of Oven/Broil Burner

Electronic oven control:

1. Open broiler door.

2. Press the “BAKE” pad.

The “BAKE” indicator will light.

“350” will appear in the display.

3. Press the START/ENTER pad.

The “TEMP” and “ON” indicators will appear.

The display will show the automatic countdown time

(10 minutes) needed to preheat the oven for selected temperature.

The oven burner should light in 20-40 seconds; this delay is normal. The oven valve requires a certain time before it will open and allow gas to flow. The oven burner will burn until oven temperature has reached 350°F (177°C). After

20-40 seconds, the oven burner will begin to cycle on and off to maintain the 350°F (177°C) temperature.

Broil burner and oven burner are the same burner. Check the broil function as follows:

1. Press the “BROIL” pad.

“525” will appear in the display.

The “BROIL” indicator will light.

2. Press the START/ENTER pad.

The “TEMP” and “ON” indicators will light.

The oven burner should light in 20-40 seconds; this delay is normal. The oven valve requires a certain time before it will open and allow gas to flow.

To avoid damaging the hot surface igniter, do not insert any object into the openings of the shield that surrounds the igniter or clean that area.

3. Check the oven burner for proper flame. The flame should be

½" (0.13 cm) long, with inner cone of bluish-green. The outer mantle should be dark blue and should be clean and soft in character. No yellow tips (not enough air), blowing or lifting

(too much air) of flame should occur.

10

If the flame needs adjusting:

1. Turn the oven off. Wait for the oven burner to cool down.

2. Open oven door and remove oven racks, oven tray, flame spreader and set aside.

A

B

A. Oven tray (lift up at area shown to remove)

B. Screws

C. Flame spreader

3. Locate the air shutter near the rear wall of oven and loosen the shutter screw.

A

C

A

B

A. Shutter screw

B. Air shutter

4. Adjust the air shutter.

5. Turn the oven back on and check for proper flame. If the flame is still not properly adjusted, turn the oven off, wait for the oven burner to cool down and repeat step 4 until flame is properly adjusted.

6. When the flame has been properly adjusted, turn the oven off, wait for the burner to cool down.

7. Tighten the shutter screw.

8. Reinstall flame spreader and oven tray. Reinstall the oven racks and close oven door.

9. Close the broiler door.

Complete Installation

1. Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.

2. Check that you have all of your tools.

3. Dispose of/recycle all packaging materials.

4. Check that the range is level. See “Level Range.”

5. Use a mild solution of liquid household cleaner and warm water to remove waxy residue caused by shipping material.

Dry thoroughly with a soft cloth. For more information, see the “Range Care” section of the Use and Care Guide.

6. Read the Use and Care Guide.

7. Turn on surface burners and oven. See the Use and Care

Guide for specific instruction on range operation.

If range does not operate, check the following:

Household fuse is intact and tight, or circuit breaker has not tripped.

Range is plugged into a grounded 3 prong outlet.

Electrical supply is connected.

See “Troubleshooting” in the Use and Care Guide.

8. When the range has been on for 5 minutes, check for heat. If the range is cold, turn off the range and check that the gas supply line shutoff valve is open.

If the gas supply line shutoff valve is closed, open it, then repeat the 5-minute test as outlined above.

If the gas supply line shutoff valve is open, turn to closed position and contact a qualified technician.

If you need Assistance or Service:

Please reference the “Assistance or Service” section of the Use and Care Guide or contact the dealer from whom you purchased your range.

11

WARNING

GAS CONVERSIONS

2. Unplug range or disconnect power.

3. Open broiler door and remove broiler pan. The gas pressure regulator is located in the back right hand corner of the broiler compartment.

A

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.

Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

Gas conversions from Natural gas to LP gas or from LP gas to

Natural gas must be done by a qualified installer.

LP Gas Conversion

WARNING

A. Gas pressure regulator

IMPORTANT: Do not remove the gas pressure regulator.

NOTE: Do not remove the spring beneath the cap.

4. Remove the cap from the gas pressure regulator using a flat-blade screwdriver.

A

A. Cap

5. Turn the cap over so the LP is visible.

A

Tip Over Hazard

A child or adult can tip the range and be killed.

Connect anti-tip bracket to rear range foot.

Reconnect the anti-tip bracket, if the range is moved.

Failure to follow these instructions can result in death or serious burns to children and adults.

To Convert Gas Pressure Regulator

1. Turn manual shutoff valve to the “closed” position.

B

A

C

A. To range

B. Manual shutoff valve “closed“ position

C. Gas supply line

12

6. Reinstall the cap.

A. Cap

For models with 3 standard burners and 1 power burner:

To Convert Surface Burners

1. Remove burner grate, burner caps and burners.

A

Std burner 88

Power burner 96

Std burner 88

Std burner 88

B

A. Burner cap

B. Burner

2. Locate LP gas orifice spuds for top burners in the literature bag included with the range. Three LP gas spuds are stamped “88” and one “96.”

3. Remove Natural gas orifice spuds using a 7 mm combination wrench.

4. Install LP gas orifice spuds using a 7 mm combination wrench.

5. Place the Natural gas orifice spuds in the parts bag for future use and keep with the bag containing literature.

6. Reinstall burners, burner caps and burner grates.

To Convert Oven Burner

1. Open the oven door and remove oven racks, oven tray, flame spreader and set aside.

2. Lift oven burner. The orifice spud is behind the oven burner air shutter.

3. Locate LP gas orifice spud stamped “56” in the bag containing literature supplied with the range.

A

B

A

B

A. Air shutter

4. Use a

³⁄₈" combination wrench and remove the Natural gas orifice spud.

5. Install the number “56” LP gas spud.

IMPORTANT: Do not overtighten.

A. Spud

B. Holder

NOTE: Depending on model, the range cooktop may be equipped with 4 standard burners or 3 standard burners and

1 power burner. Spud size and location remain the same.

For models with 4 standard burners:

Std burner 88

Std burner 88

A

A. LP oven orifice spud stamped with “56”

6. Place Natural gas oven burner spud in plastic parts bag along with Natural gas cooktop burner spuds for future use and keep with the bag containing literature.

7. Reinstall oven burner.

8. Reinstall oven racks, oven tray and flame spreader.

Std burner 88 Std burner 88

13

Complete Conversion

1. Refer to the “Make Gas Connection” section for properly connecting the range to the gas supply.

2. Turn the manual shutoff valve in the gas supply line to the open position.

3. Refer to “Check Operation” in the “Electronic Ignition

System” section for proper burner ignition, operation and burner flame adjustments.

IMPORTANT: You may have to adjust the “LO” setting for each cooktop burner.

Checking for proper cooktop and oven burner flames is very important. The small inner cone should have a very distinct blue flame ¼" to ½" (0.64 cm to 0.13 cm) long. The outer cone is not as distinct as the inner cone. LP gas flames have a slightly yellow tip.

4. Close the broiler door and turn the knob to “OFF.”

5. Refer to the “Complete Installation” section to complete this procedure.

Natural Gas Conversion

WARNING

3. Open broiler door and remove broiler pan. The gas pressure regulator is located in the back right hand corner of the broiler compartment.

A

A. Gas pressure regulator

IMPORTANT: Do not remove the gas pressure regulator.

NOTE: Do not remove the spring beneath the cap.

4. Remove the cap from the gas pressure regulator using a flat-blade screwdriver.

A

A. Cap

5. Turn the cap over so that N or NAT is visible.

A

Tip Over Hazard

A child or adult can tip the range and be killed.

Connect anti-tip bracket to rear range foot.

Reconnect the anti-tip bracket, if the range is moved.

Failure to follow these instructions can result in death or serious burns to children and adults.

A. Cap

6. Reinstall the cap.

To Convert Gas Pressure Regulator

1. Turn manual shutoff valve to the “closed” position.

B

A

C

A. To range

B. Manual shutoff valve “closed” position

C. Gas supply line

2. Unplug range or disconnect power.

14

For models with 3 standard burners and 1 power burner:

To Convert Surface Burners

1. Remove burner grate, burner caps and burners.

A

Std Burner 149

Power Burner 165

Std Burner 149

Std Burner 149

B

A. Burner cap

B. Burner

2. Locate the Natural gas orifice spuds for top burners in the literature bag included with the range. Three natural gas spuds are stamped “149” and one “165.”

3. Remove the LP gas orifice spuds using a 7 mm combination wrench.

4. Install the Natural gas orifice spuds using a 7 mm combination wrench.

5. Place LP gas orifice spuds in the parts bag for future use and keep with the bag containing literature.

6. Reinstall burners, burner caps and burner grates.

To Convert Oven Burner

1. Open the oven door and remove oven racks, oven tray, flame spreader and set aside.

2. Lift oven burner. The orifice spud is behind the oven burner air shutter.

3. Locate Natural gas orifice spud stamped “47” in the bag containing literature supplied with the range.

4. Use a

³⁄₈" combination wrench and remove the LP gas orifice spud.

5. Install the number “47” LP gas spud.

A

A

Std Burner 149

Std Burner 149

Std Burner 149

Std Burner 149

B

A. Spud

B. Holder

NOTE: Depending on model, the range cooktop may be equipped with 4 standard burners or 3 standard burners and

1 power burner. Spud size and location remain the same.

For models with 4 standard burners:

A. Natural gas oven orifice spud stamped with “47”

IMPORTANT: Do not overtighten.

6. Place LP gas oven burner spud in plastic parts bag along with LP gas cooktop burner spuds for future use and keep with the bag containing literature.

7. Reinstall oven burner.

8. Reinstall oven racks, oven tray and flame spreader.

Complete Conversion

1. Refer to the “Make Gas Connection” section for properly connecting the range to the gas supply.

2. Turn the manual shutoff valve in the gas supply line to the open position.

3. Refer to “Check Operation” in the “Electronic Ignition

System” section for proper burner ignition, operation and burner flame adjustments.

IMPORTANT: You may have to adjust the “LO” setting for each cooktop burner.

Checking for proper cooktop and oven burner flames is very important. The small inner cone should have a very distinct blue flame ¼" to ½" (0.64 cm to 0.13 cm) long. The outer cone is not as distinct as the inner cone. Natural gas flames do not have yellow tips.

4. Close the broiler door and turn the knob to “OFF.”

5. Refer to the “Complete Installation” section to complete this procedure.

15

W10032050B

© 2009.

All rights reserved.

9/09

Printed in Mexico

advertisement