GoldLine GoldLine

1A
ELECTRIC WATER BOILER
EKW AsD-W
rok założenia
1992
c
1
2
3
4
5
6
c
11:53:33
12 05 2011 czw
ESC
GoldLine
e
n
i
L
d
l
Go
=
ON
OFF
Weather compensation included
Weekly HUW programming (optional)
Build-in room temp. controler (optional)
SilverLine
+
GSM module (optional)
For independent operation or
as alternative one
CH pump, HUW pump + hydraulic
armature
Intelligent Anti Stop system
WEATHER
COMPENSATION
WEEKLY
HUW
PROGRAMMING
WEEKLY
CH
PROGRAMMING
GSM
MODULE
LCD
DISPLAY
rok założenia
1992
Technical data:
1. Hanging boiler
2. Air temperature adjustment range – depending on the
type of room thermostat
3. Electronic system fuse – 500 mA
4. Hydraulic resistance – negligible, small
5. Factory test pressure – 12 at., design pressure – 6 at.
(safety valve 3 bar, other valve on request)
6. Weight: ~28kg (depending on power rating)
7. Water volume in tank - 3l
8. Efficiency 99.5%
9. IPX2 , class 1
10. Stepless temperature adjustment 5÷70°C (CH)
11. Stepless temperature adjustment 5÷65°C (HUW)
12. 100l hanging tank with 16kW coil
Complies with the following directives:
LVD
– low-voltage directive – electric safety,
RoHS – restrictions of hazardous substances
Electronic system functions:
1. Control: room, floor
2. Multi-functional LED display
3. Automatic power selection – by 1/6 (by 1/3)
4. Manual power reduction 33-67-100%
5. Heater operation time measurement – wear
optimization
6. Smooth on/off section switching
7. Pump operation time-lag
8. Water temperature measurement and stepless
adjustment
9. Diode boiler operation displays
10. Compatible with all types of room thermostats
(dry contact). Recommendation: ThermLine RT
EMC
– electromagnetic compatibility,
WEEE – waste electrical and electronic equipment
Inspection for Environmental Protection
register no.: E0001767W
Boiler power
electronic
modulation
Heated area (m2) Alternative
heating boiler
height 2,7m
(m2)
U=0,3
Power supply
230/400V
Fuse safety
devices
(A)
by 1/3
1 phase*
1 x 20
3 x 2,5
~ 50
~ 70
by 1/3
3 phases*
3x6
5 x 1,5
~ 50
~ 70
by 1/3
1 phase*
1 x 32
3x4
~ 70
~ 100
by 1/3
3 phases*
3 x 10
5 x 2,5
~ 70
~ 100
100% - 67% - 33%
by 1/6
1 phase*
1 x 40
3x6
~ 110
~ 150
Power
Manual power distribution
on the boiler
4 kW
100% - 67% - 33%
4 kW
100% - 67% - 33%
6 kW
100% - 67% - 33%
6 kW
100% - 67% - 33%
9 kW
Power cord
in mm2
9 kW
100% - 67% - 33%
by 1/6
3 phases*
3 x 16
5 x 2,5
~ 110
~ 150
12 kW
100% - 67% - 33%
by 1/6
3 phases
3 x 20
5x4
~ 150
~ 210
15 kW
100% - 67% - 33%
by 1/6
3 phases
3 x 25
5x4
~ 180
~ 250
18 kW
100% - 67% - 33%
by 1/6
3 phases
3 x 32
5x6
~ 220
~ 310
21 kW
100% - 67% - 33%
by 1/6
3 phases
3 x 40
5x6
~ 260
~ 360
by 1/6
~ 400
24 kW
100% - 67% - 33%
3 x 40
~ 300
3 phases
5 x 10
* Boilers EKW with 4, 6 and 9 kW are preset to work on 230V. In case 400V work is essential one should
protrude bridge out of clamp bar.
ELTERM M.M. Kaszuba Sp.J.
86-200 Chełmno, ul. Przemysłowa 5
tel.(+48 56) 686 93 05, 692 06 06
POLSKA
biuro@elterm.pl www.elterm.pl
ZŁOTY CERTYFIKAT
GRAND PRIX
EKO-BUD '97
ZŁOTY CERTYFIKAT
PRZEDSIĘBIORSTWO
FAIR PLAY
2001-2011
2001
2010
ELECTRIC WATER BOILER EKW AsD-W
rok założenia
1992
1
410
270
EKW AsD-W BOILER CIRCUIT DIAGRAM
G (1-6) – HEATERS
RT – SWITCHING UNIT
BZ - ELECTRONIC SYSTEM FUSE
WT-1 – THERMAL SWITCH 100°C
LZ – TERMINAL STRIP
WT-2 – THERMAL SWITCH 60°C
P-1…P-6 – HEATER RELAYS
W-1 – MAIN SWITCH
P7 – PUMP RELAY
All ELTERM boiler
subassemblies come
from reputable
manufacturers:
L1
L2
N
L3
PE
RT
ROOM
THERMOSTAT
LZ
680
PUMP
HUW
PUMP
CH
PROCESSOR
WT-1
W-1
BZ
WT-2
boiler insulation
– mineral wool
ROCKWOOL λ0,042W/mK
55
120
105
50
P.-1
G-1
SELFA stainless
steel heaters
P.-2
P-3
P.-4
P.-5
P.-6
G-2
G-3
G-4
G-5
G-6
21
ELEMENTS INSIDE THE EKW AsD-W BOILER
21
21 - one-way valves essential
10
13
8
7
2
EKW AsD-W boiler equipment
9
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
11
16
4
vent, manometer,
safety valve and
Flamco 8 l
membrane vessel
12
3
5
External case
Mounting plate
Automatics mounting bracket
LED display
Control panel
Room thermostat terminal strip
Boiler body (tank)
Boiler insulation
Heating unit
Automatic vent 3/8" male thread
TLZ 162 (102) terminal strip
Relays
4 bar manometers
3 bar safety valve
Central heating pump
8 l membrane vessel
Supply connector pipe GZ 3/4" male thread
Return connector pipe GZ 3/4"male thread
HUW pump
Return connector pipe GZ 3/4"male thread
One-way valves
460 mm
1
Grundfos pump
2
3
4
L
net weight
830 mm
50 kg
100 l 975 mm
53 kg
80 l
1.
2.
3.
4.
5.
6.
galvanized sheet case
(CNC pressed)
Insulation
CH hot water inflow.
Circulation
Sensor cover
CH water outflow
Spiral coil
7.
8.
9.
10.
11.
Neptun Kombi
tank diagram
Sensor cover
Magnesium anode
Cold water inflow
Safety valve
Hot domestic water outflow
5
3/4"
6
7
8
L
1/2"
9
10
11
1/2"
100 mm
Shower for max 2 people
TIMEL software
OMRON subassemblies
12
9
3
6
100 l
+
1,5 kW
coil
100l tank
heating time 3-4 h
∆t=40OC
12
9
100 l
3
6
EKW-AsD boiler 12 kW
heating time
several times shorter
∆t=40OC
600 mm
6
400 mm
17 14
325 mm
19 20
18
200 mm
15
The manufacturer reserves the right to make changes to the boiler design.
ø 114 x 3.6 steel body
long life
(Polish laser cut steel)