Quorum International 20543-908 is a ceiling fan with a unique design and a host of features that make it an ideal choice for any room in your home. It comes with a limited lifetime warranty, ensuring its durability and longevity. With its elegant design and efficient performance, this fan is perfect for any modern or contemporary home.
Advertisement
Advertisement
THE TRIMARK CEILING FAN
INSTALLATION INSTRUCTIONS
Please read and save these instructions
These instructions are to be used in the installation of the following
QUORUM INTERNATIONAL fans...
The Trimark
2009
P.O.Box 961008 Fort Worth, TX 76161 (817) 626-5483 FAX (817) 626-5540 IO185-05/10
QUORUM'S UNIQUE LIMITED
LIFETIME WARRANTY
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
WHAT IS COVERED-
Except as specified below, the manufacturer of this product warrants it to be free of all defects in workmanship and material.
WHAT IS NOT COVERED BY THIS
WARRANTY-
1. All costs of removal or reinstallation of the fan.
2. Damage resulting from failure to follow instructions contained herein.
3. Damage occurring during shipment of the product (claims must be presented to the carrier).
4. Damage resulting from accident, misuse, abuse, or neglect.
5. Damage resulting from the application of any exterior coating, or by the addition of any unapproved accessories.
6. Damage resulting from repair or attempted repair by anyone other than the manufacturer.
7. Damage resulting from causes other than product defects, including lack of technical skill, competence, or experience of the user.
8. Glass or acrylic components or accessories.
9. Minor occurrences of wobble are accepted as normal and should not necessarily be considered a defect.
WHO MAY ENFORCE WARRANTY-
This warranty may be enforced only by the original purchaser. The end user must possess a dated proof of purchase from an authorized Quorum dealer to establish a warranty claim.
LENGTH OF THE WARRANTY -
1. For the fan motor - for the lifetime of the original purchaser.
2. For everything else, except blades and finish - one year from the date of purchase.
3. For fan blades and finish - 90 days from the date pf purchase.
WHAT WE WILL PAY FOR -
We agree to correct defects outlined in the warranty without charge, or at our option replace the fan with an equivalent or superior product if the defective unit is returned prepaid to us.
TO GET WARRANTY SERVICE -
To obtain warranty service, the product must be returned prepaid to Quorum.
(This warranty is not enforceable outside the United States.) Details regarding return shipment are explained elsewhere in this manual. Whenever warranty service is required, you must present a copy of the original dated sales receipt as proof of coverage.
There is no other express warranty.
Quorum hereby disclaims any and all implied warranties, including but not limited to those of merchantability of fitness for a particular purpose to the extent permitted by law. Quorum shall not be liable for incidental, consequential, or special damages arising out of or in connection with the product use or performance except as may otherwise be accorded by law. The duration of any implied warranty which cannot be disclaimed is limited to the periods specified above in the express warranty.
WARRANTY SERVICE
1. Most problems can be handled by our customer service agents over the telephone. Customers seeking warranty repair or replacement for any fan or component are encouraged to call us for assistance. All returns must be issued a
Return Goods Authorization number
(RGA) prior to returning the defective unit or part. Call (817) 626-5483 -
Monday thru Friday 8:00 a.m. - 5:00 p.m.
CST to obtain a RGA number.
3. A dated proof of purchase must accompany any fan or component clearly indicating the name of the original purchaser.
4. To avoid damage in transit, the product should be returned in its original box and packaging. Quorum will not bear responsibility for any shipping damage.
5. Any return of a fan or component must be shipped freight and insurance prepaid.
2. Arriving shipments will be refused if they do not bear a valid RGA number on the outside packaging.
FOR YOUR RECORDS
Purchased From
City State
Fan Model No.
Date Purchased
Complete and mail the enclosed warranty card within 10 days to ensure your warranty is registered.
If you have any questions regarding the warranty, or the procedures for obtaining service, please call us at
(817) 626-5483 - Monday thru Friday
8:00 a.m. - 5:00 p.m. CST.
1. SAFETY RULES
Model #20543-xxx: 18.15 lbs
1. To avoid possible electric shock, turn
off the electricity at the main fuse box or circuit panel before you begin the fan installation or before servicing the fan or installing accessories.
5. The outlet box and ceiling support joist used must be securely mounted, and
capable of supporting at least 50 pounds.
To reduce the risk of fire, electric shock, or personal injury, use only an outlet box clearly labeled "Acceptable For Fan
Support".
2. Read all instructions and safety information carefully before installing your fan and save these instructions.
3. Make sure all electrical connections comply with local codes or ordinances as well as the National Electrical Code. If you are unfamiliar with electric wiring, please use a qualified and licensed electrician.
6. To reduce the risk of personal injury use only approved hanging brackets and screws supplied with the outlet box for mounting to the outlet box.
7. After installation is complete, check that all connections are absolutely secure.
8. Do not insert anything into the fan blades while they are rotating.
4. Make sure you have a location selected for your fan which allows clear space for the blades to rotate, and at lease seven (7) feet of clearance between the floor and the fan blade tips.
9. Do not operate the reverse switch until the fan has come to a complete stop.
10. Do not attempt to control the operation of the fan (or an optional light kit) from any wall control that is not approved by Quorum for use with its fans.
Do not use solid state wall controls. The use of any unapproved control voids the fan's warranty.
11. Federal regulations require all ceiling fans with light kits manufactured or imported after January 1, 2009, to limit total wattage consumed by the light kit to
190W. Therefore, this fan is equipped with a wattage limiting device.
TOOLS REQUIRED
FOR INSTALLAITON
Phillips Screwdriver
Wire Cutters
Electrical Tape
Step Ladder
2. UNPACKING YOUR FAN
Unpack your fan and check the contents. Do not discard the carton. If warranty replacement or repair is ever necessary the fan should be returned in original packaging.
Remove all parts and hardware. Do not lay motor housing on its side - because the decorative casing may shift. Check all visible screws, bolts and nuts for tightness.
Examine all parts. The following parts should be included:
1. Set of blades (a)
2. Hanger/mounting bracket (b)
3. Ceiling canopy (c)
4. Downrod assembly (4") and
Alternate downrod (6") (d)
5. Yoke cover (e)
6. Fan motor assembly (f)
7. Mounting plate (g)
8. Light kit (h)
9. Glass shade (i)
10. Receiver (j)
11. Transmitter (k)
12. 2 x 40 Watts candelabra bulbs (l)
13. Parts bags (m) containing:
Blade attachment hardware
(Screws/washers, washers may be attached to screws)
Mounting hardware (wire nuts, wood screws, machine screws, lock washers, spring washers, metal washers.)
14. Blade balancing kit (n) a.
b.
c.
f.
d.
e.
NOTE:
Some Quorum fan models will have slightly different parts than what is shown here depending upon the design you have chosen.
Basic installation procedures are similar for all models.
g.
k.
i.
j.
h.
m.
n.
l.
IF YOU FIND THAT PARTS ARE MISSING. CONTACT YOUR DEALER FOR REPLACEMENT, OR CALL QUORUM DIRECTLY AND WE WILL MAIL REPLACEMENTS TO YOU IMMEDIATELY.
3. MOUNTING OPTIONS
1. Disconnect the power by removing fuses or turning off circuit breakers.
2. If there is an existing outlet box, ensure it is clearly marked "Suitable for Fan Support".
If it is not so marked, it must be replaced with an approved one.
WARNING:
TO REDUCE THE RISK OF ELECTRIC SHOCK, FIRE, OR PERSONAL INJURY,
MOUNT THE FAN ONLY TO AN OUTLET MARKED ACCEPTABLE FOR FAN SUPPORT AND USE
MOUNTING SCREWS PROVIDED WITH THE OUTLET BOX.
Fig. 1
Ceiling Joists
Fig. 2
Ceiling Joists
3. Secure the outlet box (or make sure the existing box is secured) directly to the building structure. Use appropriate fasteners and building materials.
Outlet Boxes Outlet Boxes
4. Figures 1,2 and 3 are examples of different ways to mount the outlet box in different situations. A longer downrod may be required in sloped ceiling situations to maintain proper blade clearance.
Fig. 3
Ceiling Joists
Fig. 4
Ceiling Joist Hanger
Support Bar
Ceiling Joist
5. To hang the fan in locations where no ceiling joist is available, a hanger support bar may be required (Figure 4). Quorum distributes approved hanger support bars and outlet boxes.
Recessed outlet Boxes
Angled ceiling maximum
24º angle
(with 4" downrod)
Outlet Boxes
CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY, INSTALL THE PRIMARY MOUNTING MEANS AND USE ONLY THE HARDWARE
PROVIDED WITH THE FAN.
4. HANGING YOUR FAN
WARNING -Turn off the power!
DO NOT fasten the blades to the fan until it is assembled and hanging from the ceiling. To do so now will likely bend the blade arms and almost certainly cause wobble.
1. (Fig. 5) Remove the set screw, set pin and safety lock clip from the yoke on top of the motor assembly. Remove three screws with lock washers from the yoke on the top of the motor housing. Remove the motor top cover from the motor.
Fig. 5
Set pin
2. (Fig. 6) Insert the blade through the slot in housing. Align holes in blade and motor and secure with 3 screws with fiber washers provided. Repeat process with the other blades. Place the motor top cover onto the top of the motor, secure by tightening the 3 screws previously removed.
Fig. 6
3. If not already affixed to the hanger bracket, place the rectangular rubber isolators between the hanger bracket and outlet box.
Secure the hanger bracket to the outlet box using the 2 long steel screws supplied with the outlex box.
4. Slide the downrod through the canopy.
Slide the yoke cover onto the downrod (Fig.
7). Feed the wires from the fan motor through the downrod assembly.
5. (Fig. 8) Attach the downrod assembly
(downrod, yoke cover and canopy) to the motor by sliding the downrod into the yoke on top of the motor assembly. Slide the set pin through the hole in the yoke, downrod and secure it with the safety lock clip.
Tighten the set screws on yoke. The yoke cover will lower down to conceal the yoke.
Feed the wires through the downrod ball.
6. Lift the fan motor without the blades and place into the hanger bracket, rotating the ball until the groove engages the tab on the hanger bracket. This locks the ball mount and fan motor, preventing fan rotation during operation. (Fig. 9)
A certain amount of wobble may be considered normal, especially if the fan is on a downrod long than 12".
Fig. 7
Screws
Yoke
Screws
Motor top cover
Yoke
Motor top cover
Set screw
Safety lock clip
Screws
Fiber washers
Blades
Downrod assembly
Canopy
Yoke cover
Fig. 8
Set pin
Fig. 9
Yoke
Downrod
Canopy
Yoke cover
Set screw
Safety lock clip
Hanger bracket
Downrod
5. ELECTRICAL CONNECTIONS
REMEMBER -Turn off the power!
Use the wire nuts supplied with your fan when making connections. Secure the connectors with electrical tape and make sure there are no loose connections or wire strands.
1. Find the DIP switches located on the side of the receiver unit. Set the switches at random to set the frequency at which the unit will operate. At least one of the four switches must be in the "ON" position.
2. Make wire connections from the fan to the wall control receiver unit. For this step use the bundle of 3 wires on the receiver. (Fig. 10)
Connect the BLACK fan wire to the
BLACK receiver wire.
Connect the BLUE fan wire to the
BLUE receiver wire.
Connect the WHITE fan neutral wire to the WHITE receiver neutral wire.
Connect the other BLACK wire (labeled
"TO POWER SUPPLY") from the transmitter to the remaining BLACK wire from the wall (A/C supply source).
If your junction box has a ground wire
(green or bare copper), connect the transmitter's ground wire to it. Otherwise, connect the transmitter ground wire directly to one of the screws from the outlet box.
Find the DIP switches located on side of the wall control unit. Ensure the setting matches the switch setting on the receiver.
Carefully tuck the connected wires inside the junction box. Secure the transmitter with the two screws provided.
Attach the face plate over the transmitter with the two screws provided.
Fig. 10
5. The wall control and receiver unit has
16 different code combinations.
Your fan will not operate if the switch settings do not match.
If you have another remote operated fan in your home, make sure its combination of switch settings are different from those of your new fan.
6. Put the receiver unit inside the canopy.
Proceed to Step 7 - Completing the
Installation.
3. Connect the wiring from the ceiling to the receiver unit. (Use the 2 wire bundle on the receiver.) Secure with supplied wire nuts.
House supply wire
BLK
Outlet box
Connect the BLACK building supply wire to the BLACK receiver wire.
Connect the WHITE receiver neutral wire to the WHITE building neutral wire.
Connect the COPPER building ground wire to the GREEN fan ground wire.
4. Connect the wiring from the wall switch receptacle to wall transmitter unit.
Remove the existing wall plate and switch from the wall junction box.
Connect one BLACK wire from the wall to one BLACK wire (labeled "TO
FAN") from the wall transmitter.
HI
MED
LOW
FAN OFF
LIGHT
OFF
ON
Wall control
NOTE: It may be necessary to bind the house wires to the corresponding receiver wires with electrical tape before capping them with wire nuts.
This will prevent them from slipping apart during the rest of the installation.
ON
Receiver
GRN
Fan canopy
Ceiling
6. COMPLETING
THE
INSTALLATION
WARNING -Turn off the power!
Fig. 11
1. Make sure the wiring is safely inside the outlet box as instructed in Step 5 -
Electrical Connections. To install the canopy, removing the 1 of 2 screws from the bottom of the mounting bracket and loosening the other one a half turn from the screw head. Slide the canopy up to mounting bracket and place the key hole on the canopy over the screw on the mounting bracket, turn canopy until it locks in place at the narrow section of the key holes.
Secure tightening the two set screws. (Fig.
11)
Screws
Fig. 12
3. Attaching the Mounting Plate (Fig. 12)
Attach the mounting plate to the flange of the motor by using the three (3) screws provided that are preinstalled on the flange.
Outlet box
Hanger bracket
Canopy
Fig. 13
Wire connector
Light kit
Mounting plate
Screws
Fig. 14 4. Attaching the Light Kit (Fig. 13)
Connect the two wiring plugs from the motor assembly to the corresponding plugs in the light kit. Attach the light kit to the mounting plate by using the three (3) screws provided that are preinstalled on the mounting plate.
Mounting plate
Fiange
Screws
5. Attaching the light bulbs and glass shade
(Fig. 14)
Install two 40W candelabra base bulbs
(included). Raise glass shade up against mounting plate and secure it to the fan by turning clockwise until snug. DO NOT
OVERTIGHTEN.
NOTE: Federal regulations require all ceiling fans with light kits manufactured or imported after January 1, 2009, to limit total wattage consumed by the light kit to 190W.
Therefore, this fan is equipped with a wattage limiting device.
Bulbs
Glass shade
7. FAN OPERATION AND CARE
1. A ceiling fan is an environmentally smart choice to cool as well as to help warm your home or office. Adjust your
HVAC thermostat during fan use to save additional energy and money on your air conditioning and heating utility bills. You should see a significant reduction in both your heating and cooling costs by regular use of your fan.
3. Clean you fan periodically using only a cloth dampened with a mild detergent solution for all hardware - never use solvents. The finish plating is lacquered to prevent tarnishing. Use a lint-free cloth with clean water to clean blades.
4. You will never need to oil or lubricate your fan. Its permanently sealed bearings will provide trouble free, silent operation for many years.
Do not hesitate to use your fan during summer and winter months. In summer,
(Fig. 15) using the reverse switch(raise up the yoke cover), adjust the fan's direction so cool air is blown down, producing a cooling breeze. In winter, (Fig. 16) reverse the fan so that an upward airflow will push warm air off the ceiling and circulate it downwards into the living area. In winter months, use the fan at a lower speed than summer.
5. If repairs or servicing are ever required, to avoid possible electric shock,
turn off the electricity at the main fuse or circuit panel before you begin.
2. Periodically check tightness of all screws securing the blades to the blade arm attachment points. A clicking or a rattling noise is a sure indication of loosening screws. Since screws will invariably work loose over time, at least once a year, tighten all the screws attaching blades to blade arms. Do not bend blade arms when cleaning or servicing the fan.
Fig. 15
Fig. 16
WINTER
8. TROUBLESHOOTING
FAN WILL NOT START
1. Check that the electricity has been turned on at the circuit breaker which had probably been turned off during installation.
2. Turn off the electricity. Check all connections in the wiring of the fan at the ceiling and make sure it follows the wiring instructions outlined in this manual.
3. Be sure on/off power switch on the wall control is in the "on" position.
5. Check that the canopy in not touching the ceiling.
4. Check the DIP switches on the side of the wall control unit to ensure they are set to the same frequency as on the receiver unit. (Refer to Section 6 "Electrical
Connections")
3. Use of a standard light rheostat or an unapproved fan wall control to control the fan speed will always cause an annoying
"hum". Many fan motors do not work quietly with solid state variable speed controls.
4. Check that the rubber gasket on the mounting bracket has been installed if called for in the installation instructions.
6. Check that all screws on the motor housing and the bottom housing are tight.
FAN TURNS, BUT DOES NOT MOVE
MUCH AIR
1. The fan may be running in reverse.
The reverse switch located on top of fan motor housing. (see Fig. 17)
NOISE
Note: Always allow a day or two "run-in" time for any new fan at medium or high speed. When attempting to diagnose noise, listen carefully from several sides to try and isolate the location of the noise
(blade, upper end, motor, light kit, etc.)
2. The distance from the ceiling to the blades may be too small. For downrod fans, optimal placement would be 8-9 feet from the floor.
3. The room may contain items which obstruct the air flow.
1. Tighten all screws attaching blades to blade arms. Remember to tighten these screws at least once a year because they may loosen slowly over time and cause a clicking noise.
4. The fan may be too small for the size of the room.
Fig. 17
2. Turn off the power. Loosen the canopy and check that the wiring and/or wire nut connectors are not resting against the canopy, possibly vibrating while the fan is on.
Reverse switch
EXCESSIVE WOBBLE
Note: A small amount of wobble is considered acceptable and should not be considered a defect.
1. Make certain all blades are tightly attached to each blades' respective blade arm.
LIGHTS SHUT OFF AND WILL NOT
COME BACK ON
1. This unit is equipped with a wattage limiting device. Lamping in excess of 190 watts will disable your ceiling fan's light kit. To reset your light kit you must turn the power off and re lamp, keeping the wattage under 190 watts. Restore power to your ceiling fan and continue normal operation.
NOTE: Federal regulations require all ceiling fans with light kits manufactured or imported after January 1, 2009, to limit total wattage consumed by the light kit to 190W. Therefore, this fan is equipped with a wattage limiting device.
REPLACEMENT PARTS AVAILABLE
A full range of genuine replacement spare parts are available at reasonable cost directly form Quorum
International. Please call us at (817)
626-5483. Monday through Friday from 8:00 A.M. to 5:00 P.M. CST.
Advertisement