Rane CP64 Spec Sheet

Add to my manuals
6 Pages

advertisement

Rane CP64 Spec Sheet | Manualzz
DATA SHEET
CP 64
COMMERCIAL PROCESSOR
General Description
The CP 64 is a versatile commercial preamplifier designed
for use in restaurants, bars, health clubs and offices. The
CP 64 is capable of serving two independent Zones. Two
gated Paging inputs and four Program inputs are provided.
Ports are provided for expansion of Page, Program or Zone
signals. Four levels of priority are supported:
• Priority Page
• Non-Priority Page
• Priority Program
• Non-Priority Program
The versatility of the CP 64 allows a wide variety of
system configurations while providing simple and intuitive
controls.
Two gated Paging Inputs capable of receiving mic or line
level input are provided. Each features independent Mic/Line
Pad, Gain Trim, detector Threshold, Zone Assign and Zone
Level controls. Internally selectable phantom power is
provided for each input. Each Paging input may be summed
Pre- or Post- Zone Level control to allow setting Paging Level
independent of Zone Level. An internal Paging Priority
switch allows a “master” pager to override non-priority
paging in its assigned zones, while allowing true dual zone
independent paging. If no Paging Priority is selected, the
Paging inputs mix together for applications like karaoke.
Four stereo Program inputs are provided with independent
Input Level controls. Any one of the four Program inputs may
be independently assigned in each Zone. One of the Program
inputs is a gated Priority Program input. When signal is
detected at its input, it overrides any non-priority Program
selection in the assigned Zones. The Priority detector features
internal, adjustable Threshold and Release-Time controls.
The CP 64 has two Zone outputs: Zone 1 is stereo: Zone 2
is mono. Each Zone features independent
• Level
• Program Select
• Ducker On/Off
• Ducker Depth
• Servo-Locked-Limiter™
• 7 Band EQ (±12 dB)
Versatile wired remote control interface ports are provided
for Paging assignment, Zone Level and Zone Program source
selection. Paging Zone and Source/Volume remote controls
are available as accessories.
An optional security cover is available for the CP 64’s
front panel. Front Panel Ducker Depth controls are screw
driver adjust. All other front panel knobs can be removed and
replaced with hole plugs. The remote controls allow blank
Decora™ switch covers to act as remote control security
covers. The remote knobs can also be replaced with the
included hole plugs.
Features
•
•
•
•
•
•
New! Faster Page Mic Detection (.5 ms)
Two fully independent gated Mic/Line Paging Inputs
Paging Priority Assign
Page Ducking
Three Stereo Program Inputs
One gated Stereo Priority Program Input
•
•
•
•
•
•
Page/Program/Zone Expansion
7-Band Graphic EQ for Each Zone
Servo-Locked-Limiter™ for Each Zone
PR 2 Remote Page Assign Controller Available
ZR 1 Remote Zone Level/Program Select Controller Available
UL/CSA/CE and 100/120/230 VAC Remote Power Supplies
Data Sheet-1
Parameter
Specification
MIC/LINE PAGING INPUTS
..........Number of inputs
..........Input Type
..........RFI Filter
..........Gain range
..........Frequency Response
..........Input Referred Noise
..........CMR
..........THD+N
..........Phantom Power
..........Mic Input impedance
..........Line Pad
..........Line Input impedance
..........Signal Detector Range
..........Signal Detector Attack
..........Signal Detector Release
..........Overload Indicator
..........Front Panel Zone Assign
..........Remote Zone Assign
Two
Balanced
Yes
+30 to +60
30 Hz to 40 kHz
-125
40
.05
+15
500
30
14.5k
off to +4
.5
3
+16
Remote, Z1, Z2, Both
Off, Z1, Z2, Both
..........Pre/Post Paging assign
..........Page Priority Assign
..........Paging Zone Level Adjust
..........Page Remote Selector
PROGRAM INPUTS
..........Number of inputs
..........Input Type
..........Input Level adjust
..........Frequency Response
..........Input impedance
.....Priority Program Input
...............Input Detector Range
...............Release Time Range
...............Attack Time
...............Assign
EXPAND OUTPUTS
..........Number of Expand Outputs
..........Expand Selector
..........Output Type
..........Gain: Zone
....................Page/Program
..........Frequency Response
..........S/N
..........THD+N
..........Crosstalk
..........Output impedance
..........Maximum Output
Data Sheet-2
Summed with program Pre
VCA or Post VCA
P1 (Page 1)
NO (none)
P2 (Page 2)
off to 0
11 = Off
10 = Z1 (Zone 1)
01 = Z2 (Zone 2)
00 = Both
Four
Unbalanced
off to 0
10 Hz to 50 kHz
10 k
off to -35
5 to 20
50
OFF, Z1, Z2 or Both
Two
Zone
Program only
Page only
Balanced
12
6
10 Hz to 50 kHz
-84
.05
-75
100
+24 dBu
Limit
Units
Conditions/Comments
All controls duplicated for both inputs
Input connector: Euroblock
Instrumentation Amplifier
2
+0/-3
1
min
.01
4%
1%
1
1%
typ
typ
typ
1
dB
dB
dBu
dB
%
VDC
ohms
dB
ohms
dBu
msec
sec
dBu
Continuously adjustable
Maximum gain
Gain: 60 dB, Rs: 150 ohms, BW: 20 kHz
20 to 20 kHz
Gain: 30 dB, +4 dBu out, 1 kHz, BW: 80 kHz
Internal switch
Each leg to GND
1
dBu
1
dB
dBu
Priority pager overrides non-priority pager
only in assigned zones; Selecting NONE
allows the two pagers to mix.
Independent for each Zone
Internal pull-up. Active low; Switch closure to
GND or 5 volt TTL logic
Each leg to GND. Defeats phantom power
Continuously adjustable
Fixed
Fixed
4 dB before clipping
Z1 = Zone 1; Z2 = Zone 2
Internal pull-up; Active low; Switch closure to
GND or 5 volt TTL logic.
Internal switch
All controls duplicated for all four inputs
Stereo
RCA input connector
+0/-3
20%
dB
dB
ohms
typ
typ
typ
dBu
sec
msec
Internal trim, factory set to -50 dBu
Internal trim, factory set to 12 seconds
For a 20 dB step; Fixed
All controls duplicated for both zones
Z1 & Z2, both mono
Note: If a Page signal is summed Post-VCA,
it is not present on the Expand Zone output. It
is available for the Expand Page output.
Cross-coupled; Euroblock connector
1
1
+0/-3
1
.01
max
1%
typ
dB
dB
dB
dBr
%
dB
ohms
re +4 dBu. BW: 20 Hz-20 kHz
+4 dBu, 1 kHz, BW: 80 kHz
1 kHz, RS: 25W, ch/ch
Each leg
Ri: 2 k ohms
Parameter
ZONE OUTPUTS
..........Number of outputs
..........Output Type
..........Gain: From Program Inputs
....................From Page Inputs
..........Frequency Response
..........S/N
..........THD+N
..........Crosstalk
..........Output impedance
..........Maximum Output
..........Signal Present Indicator
..........Overload Indicator
..........Ducker: Enable
...............Depth Range
..........Limiter: Threshold Range
...............Attack Time
...............Release Time
...............Ratio
PROGRAM SELECTION
..........Local (Front Panel)
..........Zone RMT Selector
..........Zone RMT Volume
(RMT engaged)
..........Off Isolation
EQ CIRCUITS
..........Boost/Cut Range
..........ISO Center Frequencies
..........Filter Bandwidth
Unit: Agency Listing
..........120 VAC model
..........230 VAC model
Power Supply: Agency Listing
..........120 VAC model
..........230 VAC model
Power Supply Requirements
Maximum Current
Unit: Construction
..........Size
..........Weight
Shipping: Size
..........Weight
Note: 0 dBu = 0.775 Vrms
Specification
Two
Balanced
12
6
10 Hz to 50 kHz
-84
.05
-75
100
+20
-20
+16
ON/OFF
-50 to -6
-20 to +20
20
250
15:1
L1, L2, L3 or P (priority)
11 = L1
10 = L2
00 = L3
01 = P
Attenuation = 64 mV/dB
Range 0 V to +5 V
(0 dB to -78 dB)
-80
+12 to -12
40, 100, 250, 630, 1.6k
4k, 10k
2
Limit
Units
Conditions/Comments
Zone 1 Stereo, Zone 2 mono
Euroblock connectors; Cross-coupled
1
1
+0/-3
1
.01
max
1%
typ
typ
typ
dB
dB
dB
dBr
%
dB
ohms
dBu
dBu
dBu
typ
typ
typ
typ
typ
dB
dB
msec
msec
re +4 dBu. BW: 20 Hz-20 kHz
+4 dBu, 1 kHz, BW: 80 kHz
1 kHz, RS: 25 ohms, (L/R or ch/ch)
Each Leg
Rl = 600 ohms
Maximum
4 dB before clipping
Independently defeatable for each Zone
Continuously adjustable
Continuously adjustable
For a 10 dB step; Fixed
For a 10 dB step; Fixed
Soft knee
Independent for each Zone
Internal pull-up. Active low. Switch closure to
GND or 5 volt TTL. Gray Code logic.
Control element: 2k ohm pot, reverse-log taper;
Or any GND referenced 0-5 VDC control.
typ
dB
.5
3%
dB
Hz
3%
oct
1 kHz, Rs: 25 ohms
Zone 1: Stereo 7-band
Zone 2: Mono 7-band
Class 2 Equipment
UL
CSA
CE-EMC
CE-Safety Exempt
National Electrical Code
Exempt Class 2 equipment
Exempt Class 2 equipment
EMC directive 89/336/EEC
Per Article 1 of LVD 73/23/EEC
UL
CSA
CE-EMC
CE-Safety
18 VAC w/ center tap
750
All Steel
1.75""H x 19""W x 8.5""D
5 lb (w/o power supply)
4.5"" x 20.3"" x 13.75""
9 lb
File No. E88261
File No. LR58948
EMC directive 89/336/EEC
LVD directive 73/23/EEC
RS 1 (see data sheet)
RMS current from Remote Supply
.1
Vrms
mA
1U (4.4 cm x 48.3 cm x 21.6 cm)
(2.3 kg)
(11.5 cm x 52 cm x 35 cm)
(4.1 kg)
Data Sheet-3
CP 64 Block Diagram
Data Sheet-4
Remote Controlling the CP 64
Two optional wired remote control units are available.
The PR 2 allows remote control of Page 1 and Page 2 Zone
Assign selection. The ZR 1 allows remote control of Zone
Level and Zone Program selection. One PR 2 and two ZR 1
remotes may be used with each CP 64. The PR 2 and ZR 1
may be installed in standard electrical boxes (minimum depth
2.25"). The remotes connect to the CP 64 through 5-pin
Euroblock connectors.
The PR 2 is a 5-wire remote with 2 bits to select Page 1
Assign, one wire for shield/gnd and 2 bits for Page 2 Assign.
Selector logic is active low BCD with pull-up provided in the
CP 64. Control may be a simple switch closure to GND or 5
volt TTL. Page 1 and Page 2 bits may be paralleled so that
one switch controls both Page Assigns. Remote control is
initiated by setting the front panel Paging Zone Assign
selector to RMT.
The ZR 1 is a 5-wire remote with 2 bits for Zone Program
selection (active low Gray Code), a common shield/gnd and
two wires for ratiometric DC control of Zone Level. Zone 1
and Zone 2 ZR 1 remote ports may be paralleled so that a
single remote controls both Zones. Selector logic is active low
Gray Code with pull-up provided in the CP 64. Control may
be a simple switch closure to GND or 5 volt TTL. Remote
control for each zone is initiated by engaging the RMT switch
(located on the front panel) for that Zone.
Example System — Restaurant / Lounge
Data Sheet-5
CP 64
COMMERCIAL PROCESSOR
Rear Panel
Architectural Specifications
The Processor shall provide two fully independent gated
Paging inputs, three line-level Non-Priority Program inputs
and one gated line-level Priority Program input. Two Zones
shall be served. Zone 1 shall be a stereo zone with balanced,
cross-coupled outputs. Zone 2 shall be a mono zone with a
balanced cross-coupled output. Mono expansion ports for
Page, Program or Zone signals shall be provided for each
zone. Wired remote control ports shall be provided for Paging
Zone Assign, Zone Program Select and Zone Level.
Page inputs shall use 5 pin Euroblock connector. Paging
controls shall include:
• 30 dB Mic/Line Input Pad.
• Input Gain trim range of 30 dB to 60 dB.
• Mic gate Threshold (range -¥ to +4 dBu).
• 15 volt Phantom Power (internal switch).
• Paging Priority (Page 1, None, Page 2; internal switch).
• Pre- or Post- Zone Level summing (internal switch).
• Front panel Paging Zone Assign (RMT, Z1, Z2, Both).
• Remote Paging Zone Assign (Off, Z1, Z2, Both).
• Paging Zone Level.
Each Program input shall have stereo RCA input jacks and
Independent input Level control. The Priority Program Assign
switch shall provide Priority Program override to Zone 1,
Zone 2, Both, or neither (off). The gated Priority Program
input shall have internally adjustable Threshold and ReleaseTime controls.
Zone outputs shall use 5-pin Euroblock connectors. Zone
controls shall include:
• Ducker On/Off
• Ducker depth (-6 to -50 dB)
• Program Select (L1, L2, L3, P)
• Zone Level
• 7 Band Graphic EQ (±12 dB)
• Servo-Locked-Limiter™ Threshold (-20 to +20 dBu)
• Mono switch for Zone 1 (internal)
• Remote Engage switch
Wired Remote Ports shall use 5 pin Euroblock connectors.
Remote logic shall be active low with internal pull-up.
Remote Level control shall be ratiometric DC control with 5
volt reference.
The unit shall be exempt from agency safety requirements
and powered from a UL listed, CSA certified remote power
supply (meeting CE-EMC requirements for 230 VAC).
Components shall mount on double sided, through-holeplated, G10FR Epoxy board. The chassis shall be constructed
entirely from cold-rolled steel, and mount into a standard EIA
relay rack occupying one rack space.
Reliability and Efficiency are to be primary design
considerations.
The unit shall be a Rane Corporation CP 64 Commercial
Processor.
Available Accessories
•
•
•
•
SC 1.7 Security Cover
PR 2 Page Assign Remote Control
ZR 1 Zone Source/Volume Remote Control
Hole Plugs (6 Provided)
©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5098 TEL (425)355-6000 FAX (425)347-7757 WEB http://www.rane.com
Data Sheet-6
All features & specifications subject to change without notice. DOC 102906 P/N 08761

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement