- No category
advertisement
▼
Scroll to page 2
of 6
DATA SHEET CP 64 COMMERCIAL PROCESSOR General Description The CP 64 is a versatile commercial preamplifier designed for use in restaurants, bars, health clubs and offices. The CP 64 is capable of serving two independent Zones. Two gated Paging inputs and four Program inputs are provided. Ports are provided for expansion of Page, Program or Zone signals. Four levels of priority are supported: • Priority Page • Non-Priority Page • Priority Program • Non-Priority Program The versatility of the CP 64 allows a wide variety of system configurations while providing simple and intuitive controls. Two gated Paging Inputs capable of receiving mic or line level input are provided. Each features independent Mic/Line Pad, Gain Trim, detector Threshold, Zone Assign and Zone Level controls. Internally selectable phantom power is provided for each input. Each Paging input may be summed Pre- or Post- Zone Level control to allow setting Paging Level independent of Zone Level. An internal Paging Priority switch allows a “master” pager to override non-priority paging in its assigned zones, while allowing true dual zone independent paging. If no Paging Priority is selected, the Paging inputs mix together for applications like karaoke. Four stereo Program inputs are provided with independent Input Level controls. Any one of the four Program inputs may be independently assigned in each Zone. One of the Program inputs is a gated Priority Program input. When signal is detected at its input, it overrides any non-priority Program selection in the assigned Zones. The Priority detector features internal, adjustable Threshold and Release-Time controls. The CP 64 has two Zone outputs: Zone 1 is stereo: Zone 2 is mono. Each Zone features independent • Level • Program Select • Ducker On/Off • Ducker Depth • Servo-Locked-Limiter™ • 7 Band EQ (±12 dB) Versatile wired remote control interface ports are provided for Paging assignment, Zone Level and Zone Program source selection. Paging Zone and Source/Volume remote controls are available as accessories. An optional security cover is available for the CP 64’s front panel. Front Panel Ducker Depth controls are screw driver adjust. All other front panel knobs can be removed and replaced with hole plugs. The remote controls allow blank Decora™ switch covers to act as remote control security covers. The remote knobs can also be replaced with the included hole plugs. Features • • • • • • New! Faster Page Mic Detection (.5 ms) Two fully independent gated Mic/Line Paging Inputs Paging Priority Assign Page Ducking Three Stereo Program Inputs One gated Stereo Priority Program Input • • • • • • Page/Program/Zone Expansion 7-Band Graphic EQ for Each Zone Servo-Locked-Limiter™ for Each Zone PR 2 Remote Page Assign Controller Available ZR 1 Remote Zone Level/Program Select Controller Available UL/CSA/CE and 100/120/230 VAC Remote Power Supplies Data Sheet-1 Parameter Specification MIC/LINE PAGING INPUTS ..........Number of inputs ..........Input Type ..........RFI Filter ..........Gain range ..........Frequency Response ..........Input Referred Noise ..........CMR ..........THD+N ..........Phantom Power ..........Mic Input impedance ..........Line Pad ..........Line Input impedance ..........Signal Detector Range ..........Signal Detector Attack ..........Signal Detector Release ..........Overload Indicator ..........Front Panel Zone Assign ..........Remote Zone Assign Two Balanced Yes +30 to +60 30 Hz to 40 kHz -125 40 .05 +15 500 30 14.5k off to +4 .5 3 +16 Remote, Z1, Z2, Both Off, Z1, Z2, Both ..........Pre/Post Paging assign ..........Page Priority Assign ..........Paging Zone Level Adjust ..........Page Remote Selector PROGRAM INPUTS ..........Number of inputs ..........Input Type ..........Input Level adjust ..........Frequency Response ..........Input impedance .....Priority Program Input ...............Input Detector Range ...............Release Time Range ...............Attack Time ...............Assign EXPAND OUTPUTS ..........Number of Expand Outputs ..........Expand Selector ..........Output Type ..........Gain: Zone ....................Page/Program ..........Frequency Response ..........S/N ..........THD+N ..........Crosstalk ..........Output impedance ..........Maximum Output Data Sheet-2 Summed with program Pre VCA or Post VCA P1 (Page 1) NO (none) P2 (Page 2) off to 0 11 = Off 10 = Z1 (Zone 1) 01 = Z2 (Zone 2) 00 = Both Four Unbalanced off to 0 10 Hz to 50 kHz 10 k off to -35 5 to 20 50 OFF, Z1, Z2 or Both Two Zone Program only Page only Balanced 12 6 10 Hz to 50 kHz -84 .05 -75 100 +24 dBu Limit Units Conditions/Comments All controls duplicated for both inputs Input connector: Euroblock Instrumentation Amplifier 2 +0/-3 1 min .01 4% 1% 1 1% typ typ typ 1 dB dB dBu dB % VDC ohms dB ohms dBu msec sec dBu Continuously adjustable Maximum gain Gain: 60 dB, Rs: 150 ohms, BW: 20 kHz 20 to 20 kHz Gain: 30 dB, +4 dBu out, 1 kHz, BW: 80 kHz Internal switch Each leg to GND 1 dBu 1 dB dBu Priority pager overrides non-priority pager only in assigned zones; Selecting NONE allows the two pagers to mix. Independent for each Zone Internal pull-up. Active low; Switch closure to GND or 5 volt TTL logic Each leg to GND. Defeats phantom power Continuously adjustable Fixed Fixed 4 dB before clipping Z1 = Zone 1; Z2 = Zone 2 Internal pull-up; Active low; Switch closure to GND or 5 volt TTL logic. Internal switch All controls duplicated for all four inputs Stereo RCA input connector +0/-3 20% dB dB ohms typ typ typ dBu sec msec Internal trim, factory set to -50 dBu Internal trim, factory set to 12 seconds For a 20 dB step; Fixed All controls duplicated for both zones Z1 & Z2, both mono Note: If a Page signal is summed Post-VCA, it is not present on the Expand Zone output. It is available for the Expand Page output. Cross-coupled; Euroblock connector 1 1 +0/-3 1 .01 max 1% typ dB dB dB dBr % dB ohms re +4 dBu. BW: 20 Hz-20 kHz +4 dBu, 1 kHz, BW: 80 kHz 1 kHz, RS: 25W, ch/ch Each leg Ri: 2 k ohms Parameter ZONE OUTPUTS ..........Number of outputs ..........Output Type ..........Gain: From Program Inputs ....................From Page Inputs ..........Frequency Response ..........S/N ..........THD+N ..........Crosstalk ..........Output impedance ..........Maximum Output ..........Signal Present Indicator ..........Overload Indicator ..........Ducker: Enable ...............Depth Range ..........Limiter: Threshold Range ...............Attack Time ...............Release Time ...............Ratio PROGRAM SELECTION ..........Local (Front Panel) ..........Zone RMT Selector ..........Zone RMT Volume (RMT engaged) ..........Off Isolation EQ CIRCUITS ..........Boost/Cut Range ..........ISO Center Frequencies ..........Filter Bandwidth Unit: Agency Listing ..........120 VAC model ..........230 VAC model Power Supply: Agency Listing ..........120 VAC model ..........230 VAC model Power Supply Requirements Maximum Current Unit: Construction ..........Size ..........Weight Shipping: Size ..........Weight Note: 0 dBu = 0.775 Vrms Specification Two Balanced 12 6 10 Hz to 50 kHz -84 .05 -75 100 +20 -20 +16 ON/OFF -50 to -6 -20 to +20 20 250 15:1 L1, L2, L3 or P (priority) 11 = L1 10 = L2 00 = L3 01 = P Attenuation = 64 mV/dB Range 0 V to +5 V (0 dB to -78 dB) -80 +12 to -12 40, 100, 250, 630, 1.6k 4k, 10k 2 Limit Units Conditions/Comments Zone 1 Stereo, Zone 2 mono Euroblock connectors; Cross-coupled 1 1 +0/-3 1 .01 max 1% typ typ typ dB dB dB dBr % dB ohms dBu dBu dBu typ typ typ typ typ dB dB msec msec re +4 dBu. BW: 20 Hz-20 kHz +4 dBu, 1 kHz, BW: 80 kHz 1 kHz, RS: 25 ohms, (L/R or ch/ch) Each Leg Rl = 600 ohms Maximum 4 dB before clipping Independently defeatable for each Zone Continuously adjustable Continuously adjustable For a 10 dB step; Fixed For a 10 dB step; Fixed Soft knee Independent for each Zone Internal pull-up. Active low. Switch closure to GND or 5 volt TTL. Gray Code logic. Control element: 2k ohm pot, reverse-log taper; Or any GND referenced 0-5 VDC control. typ dB .5 3% dB Hz 3% oct 1 kHz, Rs: 25 ohms Zone 1: Stereo 7-band Zone 2: Mono 7-band Class 2 Equipment UL CSA CE-EMC CE-Safety Exempt National Electrical Code Exempt Class 2 equipment Exempt Class 2 equipment EMC directive 89/336/EEC Per Article 1 of LVD 73/23/EEC UL CSA CE-EMC CE-Safety 18 VAC w/ center tap 750 All Steel 1.75""H x 19""W x 8.5""D 5 lb (w/o power supply) 4.5"" x 20.3"" x 13.75"" 9 lb File No. E88261 File No. LR58948 EMC directive 89/336/EEC LVD directive 73/23/EEC RS 1 (see data sheet) RMS current from Remote Supply .1 Vrms mA 1U (4.4 cm x 48.3 cm x 21.6 cm) (2.3 kg) (11.5 cm x 52 cm x 35 cm) (4.1 kg) Data Sheet-3 CP 64 Block Diagram Data Sheet-4 Remote Controlling the CP 64 Two optional wired remote control units are available. The PR 2 allows remote control of Page 1 and Page 2 Zone Assign selection. The ZR 1 allows remote control of Zone Level and Zone Program selection. One PR 2 and two ZR 1 remotes may be used with each CP 64. The PR 2 and ZR 1 may be installed in standard electrical boxes (minimum depth 2.25"). The remotes connect to the CP 64 through 5-pin Euroblock connectors. The PR 2 is a 5-wire remote with 2 bits to select Page 1 Assign, one wire for shield/gnd and 2 bits for Page 2 Assign. Selector logic is active low BCD with pull-up provided in the CP 64. Control may be a simple switch closure to GND or 5 volt TTL. Page 1 and Page 2 bits may be paralleled so that one switch controls both Page Assigns. Remote control is initiated by setting the front panel Paging Zone Assign selector to RMT. The ZR 1 is a 5-wire remote with 2 bits for Zone Program selection (active low Gray Code), a common shield/gnd and two wires for ratiometric DC control of Zone Level. Zone 1 and Zone 2 ZR 1 remote ports may be paralleled so that a single remote controls both Zones. Selector logic is active low Gray Code with pull-up provided in the CP 64. Control may be a simple switch closure to GND or 5 volt TTL. Remote control for each zone is initiated by engaging the RMT switch (located on the front panel) for that Zone. Example System — Restaurant / Lounge Data Sheet-5 CP 64 COMMERCIAL PROCESSOR Rear Panel Architectural Specifications The Processor shall provide two fully independent gated Paging inputs, three line-level Non-Priority Program inputs and one gated line-level Priority Program input. Two Zones shall be served. Zone 1 shall be a stereo zone with balanced, cross-coupled outputs. Zone 2 shall be a mono zone with a balanced cross-coupled output. Mono expansion ports for Page, Program or Zone signals shall be provided for each zone. Wired remote control ports shall be provided for Paging Zone Assign, Zone Program Select and Zone Level. Page inputs shall use 5 pin Euroblock connector. Paging controls shall include: • 30 dB Mic/Line Input Pad. • Input Gain trim range of 30 dB to 60 dB. • Mic gate Threshold (range -¥ to +4 dBu). • 15 volt Phantom Power (internal switch). • Paging Priority (Page 1, None, Page 2; internal switch). • Pre- or Post- Zone Level summing (internal switch). • Front panel Paging Zone Assign (RMT, Z1, Z2, Both). • Remote Paging Zone Assign (Off, Z1, Z2, Both). • Paging Zone Level. Each Program input shall have stereo RCA input jacks and Independent input Level control. The Priority Program Assign switch shall provide Priority Program override to Zone 1, Zone 2, Both, or neither (off). The gated Priority Program input shall have internally adjustable Threshold and ReleaseTime controls. Zone outputs shall use 5-pin Euroblock connectors. Zone controls shall include: • Ducker On/Off • Ducker depth (-6 to -50 dB) • Program Select (L1, L2, L3, P) • Zone Level • 7 Band Graphic EQ (±12 dB) • Servo-Locked-Limiter™ Threshold (-20 to +20 dBu) • Mono switch for Zone 1 (internal) • Remote Engage switch Wired Remote Ports shall use 5 pin Euroblock connectors. Remote logic shall be active low with internal pull-up. Remote Level control shall be ratiometric DC control with 5 volt reference. The unit shall be exempt from agency safety requirements and powered from a UL listed, CSA certified remote power supply (meeting CE-EMC requirements for 230 VAC). Components shall mount on double sided, through-holeplated, G10FR Epoxy board. The chassis shall be constructed entirely from cold-rolled steel, and mount into a standard EIA relay rack occupying one rack space. Reliability and Efficiency are to be primary design considerations. The unit shall be a Rane Corporation CP 64 Commercial Processor. Available Accessories • • • • SC 1.7 Security Cover PR 2 Page Assign Remote Control ZR 1 Zone Source/Volume Remote Control Hole Plugs (6 Provided) ©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5098 TEL (425)355-6000 FAX (425)347-7757 WEB http://www.rane.com Data Sheet-6 All features & specifications subject to change without notice. DOC 102906 P/N 08761
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project