new product guide - Products

new product guide - Products
PRELIMINARY
NEW PRODUCT
GUIDE
Zoneline® Packaged Terminal
Air Conditioners
GE ZONELINE
®
A Story of American Invention
In 1961, the GE Zoneline® PTAC began making its way into hotels and
motels across the country, changing the face of comfort on the road.
Now, over 50 years later, GE Zoneline has been reinvented in Louisville,
Kentucky, to meet the changing needs of America’s hotel industry.
The newest GE Zoneline PTACs are engineered to be more reliable,
efficient, quieter and incredibly easy to install and maintain.
2
PRELIMINARY
KEY BENEFITS HOTELIERS
WILL LOVE
The new GE Zoneline leads the
industry in four categories:
RELIABLE
QUIET
EFFICIENT
NEW APPEARANCE
3
4
PRELIMINARY
RELIABLE
With over one million units installed across the U.S. and remarkably low service issues, GE Zoneline®
PTACs offer unrivaled reliability, consistent performance and constant guest comfort.
UNMATCHED SERVICE & SUPPORT
GE Appliances is the only manufacturer with a dedicated factory service network and field team.
Our technicians service your Zoneline—and any other GE appliances you have—in no time,
so guest comfort is not compromised.
FEATURE HIGHLIGHTS:
REDESIGNED STRUCTURE | Simplified and streamlined so servicing
is faster and easier than ever before.
PREMIUM GUARD CORROSION PROTECTION | Special coatings keep
each part performing at peak condition, longer.
EASY TO SERVICE | New Zonelines have integrated structural components
for easy maintenance and support.
IMPROVED DESIGN
| Rustproof base pan comes standard on all models.
SERVICE DIAGNOSTICS PORT | Technicians can quickly diagnose problems.
QUICK CONNECT | The thermostat, central desk control and external fan
can be connected in seconds for faster installation and servicing.
5
6
PRELIMINARY
QUIET
Quiet operation has always been a strong suit of Zoneline®. It’s the quietest PTAC when compared
to leading competitors*, so you know your guests will always get a good night’s rest.
WHERE IT COUNTS
Typical outdoor noises such as those from traffic or airports present challenges to hotel owners every
day. When tested against leading competitors, GE Zonelines block the most outdoor noise with a sound
transmission class of 29*—that’s the highest PTAC STC on the market. That means Zonelines help guests
sleep better and can support high guest ratings for hotel and motel properties.
STC (Sound Transmission Class)
Guests who are dissatisfied with
the room noise or temperature:
29
33%
ARE NOT LIKELY
TO RECOMMEND
THE HOTEL**
GE Appliances
Comp A
Comp A (2)
Comp B
Comp C
66%
ARE NOT LIKELY
TO RETURN TO
THE HOTEL**
GE Appliances Zonelines provide quiet comfort for hotel rooms.
FEATURE HIGHLIGHTS:
BAKED-ON MASTIC | A heavy-duty barrier covers the back of the unit for superior sound insulation.
WEATHER BARRIER SYSTEM SEAL | A seal around the perimeter of the unit keeps noise and dirt outside.
TWO DC FAN MOTORS | A motor for each fan reduces noise by dialing in the exact airflow needed for each
heating and cooling function.
LARGE CROSS-FLOW BLOWER | Airflow is optimized for a low, balanced sound that is hardly noticeable.
SMART FAN COOLING/HEATING | Allows the fan to run in either continuous mode during hot weather
or cycle mode during the winter months, saving energy and improving guest comfort.
*12,000 BTUh heat pump models tested by independent third-party testing at a national acoustical lab, conducted March 2015 and
October 2015, in accordance with ASTM and AHRI standards. The higher the STC rating, the better the unit blocks outside noise.
**Clarabridge Ratings and Reviews, for hospitality data collected July 2013 – June 2014. “Americans' biggest complaints about hotels”
Forbes Magazine, July 27, 2012 issue.
7
FPO_Stock
8
PRELIMINARY
EFFICIENT
GE Zoneline® PTACs are highly efficient. Zoneline heat pumps can save a property hundreds
of dollars per month in utility expenses.* On average, Zoneline is 8% more efficient than the leading
competitor for 7,000 BTUh and 9,000 BTUh electric resistance heat models, for more savings per
room, per year.** That all adds up to lower operation costs.
WHY IT MATTERS
Decreasing the energy usage of your properties can save you a lot of
money. Since Zoneline PTACs are one of the industry leaders in efficient
operation, you’ll be able to cut utility bills without compromising the
comfort of your guests.
FEATURE HIGHLIGHTS:
REVERSE CYCLE DEFROST | Prolongs heat pump operation, saving
energy and money.
ELECTRONIC TEMPERATURE LIMITING | Limits are preset to save
energy and avoid excessive temperature swings.
HEAT & FREEZE SENTINELS | Specially designed sentinels protect your
property by preventing overheating or freezing.
EXTENSIVE HEAT SOURCE LOGIC | Smart technology lets each unit
automatically select the right heat source to efficiently meet guest needs.
SMART PROGRAMMING | Every unit is programmed to balance guest
comfort with efficient operation.
*Savings depend on region, equipment, structure and other factors.
**GE Zoneline AZ45 and AZ65 Series models for 7,000 BTUh and 9,000 BTUh electric resistance models, vs. leading competitor
for comparable models with average EER values of listed models, per AHRI listing October 2015.
9
10
PRELIMINARY
NEW APPEARANCE
The Zoneline® boasts a slimmer room front, sleek appearance and fresh color, providing an
updated look that blends in seamlessly with any hotel décor and room design. Even though it
has the same footprint for easy replacement, it also has the industry’s slimmest room front,
so Zoneline provides more open space for guests to enjoy.
STREAMLINED, INSIDE AND OUT
The new Zoneline looks sleeker on the outside, but is also more efficiently engineered inside.
FEATURE HIGHLIGHTS:
BACKLIT, COVERLESS CONTROL PANEL | Improved display with large, white LED lights
and no lid cover keep this unit looking like new.
SLEEK APPEARANCE | Enjoy the same case dimensions with a shallower depth for more
usable room space.
FRESH COLOR | Perfectly blends in with modern interior designs.
DIMMING DISPLAY | Automatic dimming feature makes sure LED lights are never too bright at night.
11
FEATURE HIGHLIGHTS
The new Zoneline® continues a legacy
of energy efficiency and guest comfort,
thanks to innovative features that
property managers love.
BLOWER & DC MOTORS
Cross-flow blower, two DC fan motors and smart fan
cooling and heating keep the unit quiet while providing
efficient heating and cooling performance
HEAT & FREEZE SENTINEL
Keeps room from overheating or freezing to increase
efficiency and comfort while decreasing operating and
maintenance costs
SYSTEM COMPATIBILITY
ompatible with a wide variety of thermostats
C
and energy management systems, including
central desk control
12
PRELIMINARY
PREMIUM GUARD
CORROSION PROTECTION*
Special coatings, paintings and stainless steel ensure
lasting performance in challenging environments such as
oceanfront properties
HEAT PUMP FEATURES
Reverse cycle defrost increases efficiency and allows unit to
run in heat pump mode longer
Backup resistance heat delivers quick heating comfort
Internal Condensate Removal (ICR) also available on select models
DRY AIR 25*
ELECTRONIC TOUCH CONTROLS
Patented dehumidifier heat pipe removes up to 25%
more humidity from a room
asy-to-use controls with clear LED readout
E
provide a user-friendly experience
Ideal for properties in ocean environments and
high-humidity areas
WEATHER BARRIER SYSTEM SEAL
ELECTRONIC TEMPERATURE LIMITING
Keeps noise, dirt and grime outside
Prevents expensive overcooling and overheating of rooms
Creates a quieter room and more efficient operation
Limits are automatically set, so seasonal adjustments
aren’t necessary
*Available on select models
13
RESISTANCE HEAT
4500 SERIES
RESISTANCE HEAT UNITS*
• Digital LED display
• Solid-state thermostat
• Variable vent control
• Automatic indoor frost control
• 2 DC fan motors
• Heat & Freeze Sentinel
• Remote thermostat capability
• Models with Premium Guard
Corrosion Protection are also
available*
4500 SERIES | COOLING & ELECTRIC RESISTANCE HEAT
230/208V MODELS
Cooling BTUh
EER (BTUh/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Power factor
Sensible heat ratio
@ 230 volts
Watts
Cooling amperes, F.L.
Amperes, L.R.
Weight (Net/Ship)
AZ45E07D
7,200/7,000
13.4/13.4
1.7
R-410A
290
218
89%
80%
75%
70%
70%
535/520
2.5/2.5
13.5
89/103
800/790
3.6/3.9
21.0
100/113
1,010/1,000
4.7/5.0
29.5
99/112
1,415/1,405
6.4/6.8
31.5
100.3/113.3
265V MODELS
Cooling BTUh
EER (BTUh/Watt)
Dehumidification Pts/Hr
CFM, indoor fan high
CFM, indoor fan low
Power factor
Sensible heat ratio
@ 265 volts
Watts
Cooling amperes, F.L.
Amperes, L.R.
Weight (Net/Ship)
AZ45E07E
7,200
12.3
1.7
290
215
90%
AZ45E09E
9,400
12.0
2.7
340
229
91%
AZ45E12E
11,800
11.1
3.5
420
323
92%
AZ45E15E
14,300
10.3
4.6
406
324
92%
80%
75%
70%
70%
580
2.4
11.7
92/105
805
3.2
16.5
101/114
1,025
4.1
23.5
100/113
1,385
5.7
26.0
101/114
Specifications subject to change.
*Premium Guard Corrosion Protection model BTUh and watts may vary.
14
AZ45E09D
9700/9600
12.1/12.1
2.7
R-410A
340
229
93%
AZ45E12D
11,800/11,500
11.8/11.8
3.5
R-410A
420
323
93%
AZ45E15D
14,900/14,800
10.5/10.5
4.6
R-410A
409
324
90%/92%
PRELIMINARY
RESISTANCE HEAT
4500 SERIES DRY AIR 25
RESISTANCE HEAT UNITS
• Digital LED display
• Solid-state thermostat
• Variable vent control
• Automatic indoor frost control
• 2 DC fan motors
• Heat & Freeze Sentinel
• Remote thermostat capability
• Premium Guard Corrosion Protection
standard on all Dry Air 25 models
DRY AIR 25 SERIES | COOLING & ELECTRIC RESISTANCE HEAT
230/208V MODELS
Cooling BTUh
EER (BTUh/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Power factor
Sensible heat ratio
@ 230 volts
Watts
Cooling amperes, F.L.
Amperes, L.R.
Weight (Net/Ship)
AZ45E07DAP
6,500/6,300
11.9/11.9
2.3
R-410A
220
190
86%/87%
60%
60%
60%
555/535
2.8/3.0
19.5
97.0/110.0
790/765
3.6/3.9
21.0
106/121
1,035/1,015
4.7/5.1
29.5
114/129
265V MODELS
Cooling BTUh
EER (BTUh/Watt)
Dehumidification Pts/Hr
CFM, indoor fan high
CFM, indoor fan low
Vent CFM
(full open/partial open)
Power factor
Sensible heat ratio
@ 265 volts
Watts
Cooling amperes, F.L.
Amperes, L.R.
Weight (Net/Ship)
AZ45E09EAP
9,200
11.5
2.7
340
229
AZ45E12EAP
11,200
10.8
3.5
420
323
70/45
75/45
AZ45E09DAP
9,200/8,800
11.5/11.5
3.4
R-410A
280
208
92%
91%
92%
60%
60%
805
3.2
16.5
101/114
1,025
4.1
23.5
100/113
AZ45E12DAP
11,200/11,000
10.8/10.8
4.4
R-410A
330
270
92%
Specifications subject to change.
15
HEAT PUMP
6500 SERIES
HEAT PUMP UNITS*
• Staged heating
• Heat pump with resistance heat backup
• Electric resistance heat lockout
• Reverse cycle defrost
• Models with Premium Guard Corrosion
Protection and ICR are also available**
6500 SERIES | HEAT PUMP UNITS*
230/208V MODELS
Cooling BTUh
EER (BTUh/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Power factor
Cooling watts
Cooling amperes, F.L.
Amperes, L.R.
Reverse cycle heat BTU
COP
Heating watts
Heating amperes
Weight (Net/Ship)
AZ65H07D
7,100/6,900
12.8/12.8
1.7
R-410A
340
194
91%
545/535
2.5/2.7
13.5
6,200/6,100
3.9/3.9
465/455
2.2/2.3
94/107
AZ65H09D
9,700/9,600
12.2/12.2
2.7
R-410A
360
212
92%
795/785
3.6/3.8
21.0
8,100/8,000
3.7/3.7
650/635
3.1/3.3
101/114
AZ65H12D
12,100/11,900
11.9/11.9
3.5
R-410A
370
284
92%
1,015/1,000
4.5/4.9
29.5
10,500/10,400
3.6/3.6
855/835
4.1/4.5
102/115
AZ65H15D
14,400/14,200
10.6/10.6
4.5
R-410A
370
290
91%/92%
1,355/1,335
6.1/6.5
31.5
13,400/13,300
3.3/3.3
1,190/1,180
5.2/5.6
101/114
265V MODELS
Cooling BTUh
EER (BTUh/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM
(full open/partial open)
Power factor
Sensible heat ratio
@ 265 volts
Cooling watts
Cooling amperes, F.L.
Amperes, L.R.
Reverse cycle heat BTU
COP
Heating watts
Heating amperes
Weight (Net/Ship)**
AZ65H07E
7,000
12.8
1.7
R-410A
340
194
AZ65H09E
9,400
12.2
2.7
R-410A
360
211
AZ65H12E
11,700
11.6
3.5
R-410A
370
284
AZ65H15E
14,400
10.6
4.5
R-410A
370
290
50/40
70/45
75/45
75/45
92%
90%
92%
93%
85%
75%
70%
65%
540
2.2
11.7
6,200
3.9
455
2.0
97/117
760
3.1
16.5
8,100
3.6
665
2.7
106/119
1,015
4.0
23.5
10,700
3.6
880
3.6
107/120
1,355
5.4
26.0
13,500
3.3
1,270
5.0
106/119
*Premium Guard Corrossion Protection model BTUh and watts may vary.
**ICR adds 3 pounds to unit weight.
Specifications subject to change.
16
PRELIMINARY
GE APPLIANCES
ZONELINE® WARRANTY
FOR THE PERIOD OF
GE APPLIANCES WILL REPLACE
ONE YEAR
Any part of the air conditioner which fails due to a defect in materials or workmanship. During this
limited one-year warranty, GE will provide, free of charge, all labor and related service costs to
replace the defective part.
FIVE YEARS
Sealed Refrigerating System, if any part of the Sealed Refrigerating System (the compressor,
condenser, evaporator, and all connecting tubing) should fail due to a defect in materials or
workmanship. During this limited five-year warranty, GE will provide, free of charge, all labor
and related service costs to replace the defective part.
SECOND THROUGH
FIFTH YEAR
Fan Motors, Switches, Thermostat, Heater, Heater Protectors, Compressor Overload, Solenoids,
Circuit Boards, Auxiliary Controls, Thermistors, Freeze Sentinel, Frost Controls, ICR Pump,
Capacitors, Varistors and Indoor Blower Bearing, if any of these parts should fail due to a defect in
materials or workmanship. During this additional four-year limited warranty, the customer will be
responsible for any labor and related service costs.
From the date of the
original purchase
From the date of the
original purchase
From the date of the
original purchase
ZONELINE® CHASSIS NOMENCLATURE
A
Z
6
5
Chassis series
45=cool/electric heat
65=heat pump
Unit type
E=cooling with electric
resistance heat
H=heat pump with electric
resistance heat
H
1
2
Nominal cooling capacity
07=7,000 BTUh cooling
09=9,000 BTUh cooling
12=12,000 BTUh cooling
15=15,000 BTUh cooling
Voltage/Phase/Frequency
D=230/208 Volt, single
phase, 60 Hz
E=265 Volt, single phase,
60 Hz
D
A
D
Universal
power connection
Special features
B=base unit
C=corrosion treated
D=internal condensate
removal (ICR)
system (heat pump
models only—
not for coastal
applications)
M=Makeup Air
P=Dry Air 25
17
ACCESSORIES
A look inside:
WALL CASE
CROSS-FLOW
BLOWER
GRILLE
ROOM
FRONT
CHASSIS
WALL CASE OPTIONS
THERMOSTATS
GRILLE OPTIONS
RAB71B, RAB77B
Digital – RAK148D2 , RAK164D2
Programmable – RAK148P2, RAK164P2
Architectural rear grille
Extruded aluminum – RAG67
Stamped aluminum – RAG60
Extended sleeves available in 16" and
24" depths
High-impact polymer grille
Beige – RAG61
Maple – RAG62
Bittersweet – RAG63
RETROFIT KITS
RAK40 Deflector kit
STANDARD SUB-BASE WITH
POWER CORD INCLUDED
RAK204D15PA
RAK204D20PA
RAK204D30PA
18
PRELIMINARY
POWER CONNECTION KITS ARE REQUIRED
ON ALL ZONELINE CHASSIS. (See chart below)
The correct kit for the installation is determined by the voltage and amperage of the electrical circuit and the means of
connecting the unit to the building wiring. If the unit is to be plugged into a receptacle, a line cord kit would be used; if
the unit is to be permanently connected, a permanent connection kit would be used. Cord set units of 265 volts must be
installed in compliance with National Electrical Code.®
POWER CONNECTION KITS
Required on all models. See specification information below
for heater kWh and branch circuit ampacity.
RAK315P/320P/330P
RAK315D/320D/330D
RAK515D/520D/530D
230/208 volt line cord connection kit
230/208 volt universal power supply kit
265 volt universal power supply kit
Also available with short power cords
230/208 VOLT
LCDI Power
Connection Kit
Heater kWh
Watts
BTU
Amps
Min. circuit amps
Recommended
protective device
230/208 VOLT
Heater kWh
Watts
BTU
Amps
Min. circuit amps
Recommended
protective device
7,000/9,000 BTUH
LINE CORD CONNECTED UNITS
RAK315P
2.4/1.99
2,401/1,989
8,187/6,782
10.4/9.6
15
15 amp timedelay fuse or
breaker
RAK320P
3.42/2.83
3,418/2,825
11,655/9,633
14.9/13.6
20
20 amp timedelay fuse or
breaker
RAK330P
4.83/3.98
4,827/3,984*
16,460/13,585
21.0/19.2
30
30 amp timedelay fuse or
breaker
7,000/9,000 BTUH
DIRECT CONNECTION KIT†
RAK315D
RAK320D
RAK330D
2.4/1.99
3.42/2.83
4.83/3.98
2,401/1,989
3,418/2,825
4,827/3,984*
8,187/6,782
11,655/9,633
16,460/13,585
10.4/9.6
14.9/13.6
21.0/19.2
15
20
30
15 amp time20 amp time30 amp timedelay fuse or
delay fuse or
delay fuse or
breaker
breaker
breaker
7,000/9,000 BTUH
265 VOLT PERMANENT CONNECTED UNITS** (CORD SET)
RAK515P
2.4
2,400
8,150
9.6
15
RAK520P
3.4
3,400
11,550
13.3
20
RAK530P
4.8
4,800
16,350
18.6
30
15 amp time-delay
fuse or breaker
20 amp time-delay
fuse or breaker
30 amp time-delay
fuse or breaker
7,000/9,000 BTUH
265 VOLT DIRECT CONNECTION KIT†
RAK515D
RAK520D
RAK530D
2.4
3.4
4.8
2,400
3,400
4,800*
8,150
11,550
16,350
9.6
13.3
18.6
15
20
30
15 amp time-delay
fuse or breaker
20 amp time-delay
fuse or breaker
30 amp time-delay
fuse or breaker
*Wattage less when in low fan.
**To be used with sub-base.
†To be used with sub-base or connection to building wiring.
Specifications subject to change.
Wall case and exterior grille are also required for new construction.
Specs may vary for 12,000/9,000 BTUh models.
ADDITIONAL ACCESSORIES AVAILABLE
For example, drain kits, adapter, exterior air deflector kits and filters.
Visit Zoneline.com for full listing.
19
Appliance Park
Louisville, KY 40225
geappliances.com
zoneline.com
888.231.2548
© 2016 GE Appliances
Pub. No. 20-T055
PC82903
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising