Technical Specifications Eaton 5S UPS technical specifications1
Technical
Specifications
Eaton 5S UPS technical specifications1
Model overview
Catalog
Power rating
number
(VA/watts)
Tower 120V, 50/60 Hz models
5S550
550/330
5S700
700/420
5S700LCD
700/420
5S1000LCD
1000/600
5S1500LCD
1500/900
Tower 230V, 50/60 Hz models
5S700G
700/420
5S1500G
1500/900
Input
Output
Dimensions
(HxWxD, in.)
Weight (lb.)
5-15P (6 ft)
5-15P (6 ft)
5-15P (6 ft)
5-15P (6 ft)
5-15P (6 ft)
(8) 5-15R
(8) 5-15R
(8) 5-15R
(8) 5-15R
(10) 5-15R
9.8 x 3.4 x 10.2
9.8 x 3.4 x 10.2
9.8 x 3.4 x 10.2
9.8 x 3.4 x 15.0
9.8 x 3.4 x 15.0
12.6
14.7
15.1
21.7
26.1
C14
C14
(6) C13
(8) C13
9.8 x 3.4 x 10.2
9.8 x 3.4 x 15.0
13.2
24.6
Battery runtimes2
Wattage Model
5S550
5S700 & 5S700G
5S700LCD
Wattage Model
5S1000LCD
5S1500 & 5S1500G
1500VA (LCD)
30W
60W
90W
120W
150W
180W
210W
240W
270W
300W
330W
360W
390W
420W
121
151
86
56
75
67
31
37
36
20
30
27
14
21
20
10
14
15
8
12
11
6
11
9
5
9
7
4
7
6
1
6
5
5
4
3
2
2
2
120W
180W
240W
300W
360W
420W
480W
540W
600W
660W
720W
780W
840W
900W
43
79
71
26
43
42
18
30
31
14
22
22
10
17
16
9
13
13
6
10
10
4
9
8
3
8
7
6
6
5
5
4
4
3
3
2
2
Additional specifications
General
Graphical LCD
LED
Topology
Configuration
Color
Warranty
Contents (Ships with the
following items)
5S550
5S700
None
5S700LCD
5S1000LCD
5S700G
5S1500LCD
5S1500G
Graphical display. UPS status
None
in a single view
UPS On LED
Line interactive
Tower
Black
3 years including batteries
 UPS
 Input power cord
 User manual (in 18 languages) and safety instructions
 Warranty for connected equipment
 USB cable and Software CD
G-Models only:
 2 IEC output power cords
 No input power cord
Electrical input
Nominal voltage
Default voltage
120V: 100/120/127V
230V(G models): 220/230/240V
Low Voltage: 120V
High Voltage: 230V
Page 2 of 2
Communications
Input voltage range
Frequency
Frequency range
Electrical output
On utility voltage
regulation
On battery voltage
regulation
Efficiency
Frequency tolerance
Over current protection
Battery
Battery description
Battery management
Battery replacement
Start on battery
User interface
LEDs
Communication ports
Power management
software
Environmental & standards
RoHS compliance
Surge protection
EMC compliance
Audible noise
Operating temperature
Safety Markings
Storage temperature
Relative humidity
Altitude
5S550
5S700
5S700LCD
5S1000LCD
5S1500LCD
120V: 93-138 Vac
230V: 175-275 Vac
50/60 Hz
60 Hz: 46–70 Hz
50 Hz: 57–70 Hz
5S700G
5S1500G
120V: 102-132 Vac
230V: 184-256 Vac
-20%, +15% of nominal
Normal or line mode: >95% above 60% load
±0.1Hz
Electronic current limit
Sealed, lead-acid; maintenance free
ABM technology; 3-stage charging extends battery service life by 50% and provides
advance warning for battery replacement
Tool-less, replaceable internal batteries
(not hot-swappable)
Cold-start enabled; first cold start is always forbidden
None
LCD graphical display. UPS
None
status in a single view.
UPS On LED
USB port as standard (HID)
USB Cord Included
Eaton UPS Companion Software
Yes
IEEE ANSI C62.41 Cat B2
120V: FCC Part 15 subpart B Class B
IEC 62040-2 C1/ EN 55024 / CISPR22 Class B / FCC part 15 Class B
< 25 dB at 1 meter
0° to 35°C (32°F to 95°F)
CE / cTUVus / NOM
-25°C to 40°C (-13°F to 104°F)
0 to 93% non-condensing
Up to 6,500 ft (2000m) without de-rating
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising