AVAILABLE REPAIR KITS
Rotary Head Kit - Major:
P/N 2100372
Includes items 2, 3, 4, 5, 6, 7, 8, 9,
10, 11, 12, 13, 14, 15 and 17
Rotary Head Kit - Minor:
P/N 2100203
Includes items 9, 10, 15 and 17
Complete Rotary Head Kit:
P/N 2103220
Includes all items
Optional Caster Kit:
P/N 2100200
PROFESSIONAL FLAT SURFACE CLEANER
FROM GENERAL PUMP
• COMPENSATING GUN FEATURE
• FULL 20” CLEANING PATH
• RUGGED ABS COVER
Photo of Rotary Head - Major as assembled.
ITEM
NO.
1
14
15
16
17
10
11
12
13
8
9
6
7
4
5
2
3
PART
NO.
2500010
2520030
2520028
2520027
2640004
2701012
2701011
2701010
2720007
2530008
2530007
2520029
2710000
2520113
2200092
2200050
2500012
DESCRIPTION
HOUSING
RETAINER, BEARING
RETAINER, BEARING
SPACER, BEARING
BEARING
O-RING
O-RING
O-RING
SPRING
PIN
STEM, SMALL
SNAP RING
BACK UP RING
STEM
SCREW, M5 X 16
WASHER
RETAINER, BEARING
Ref 300843 Rev. F
05-16
QTY.
1
3
1
1
3
3
1
2
1
1
1
1
1
2
2
1
1
DCFSCP20GZ
OPERATOR’S MANUAL
General Pump is a member of the
Interpump Group
Ref 300843 Rev.F
05-16
8
WARNING: Read Before Operating Machine
Always wear protective eyewear
Keep clear of rotating nozzles
Never lock trigger gun open with any device
Drain water in cold weather to avoid freezing
Tampering with any part of this machine will void all warranties
Operating Instructions
1. Bolt the two halves of the handle together with the two M6 x 60mm long bolts, nylok nuts and four washers.
2. Connect the handle to the brackets on the deck with the two 55mm long pins and rings.
3. Using thread sealant on hose’s male threads, connect the hose to the swivel on the deck.
4. Again, using thread sealant, attach the in-line filter to the inlet of the gun.
5. Connect inlet flter, D40014, to FSC gun inlet.
6. Connect to Pressure Washer.
7. Turn water on and open valve. Open trigger gun for flow of water through nozzles. Nozzles must have flowing spray. If not, remove tips and clean; reassemble, making sure that groove of nozzle is parallel to spray bar. Use thread sealant when installing nozzles.
8. Start Pressure Washer. The Hammerhead is ready for operation.
9. Walk slowly behind the Hammerhead cleaning as you go. If striping occurs, slow down your pace.
10. Periodically check weep hole on bottom of swivel. Water will seep slowly; if water shoots out, stop and replace seals. Swivel assembly can be rebuilt.
11. For maximum effectiveness keep spray tips clean. If the machine vibrates, stop and clean spray tips.
12.Grease the swivel with one or two grease gun pumps every 200 hours (or once about every 30 days of use). Use No. 2 general purpose waerproof lithium grease. For hot water applications, use a quality high temperaure grease.
NOTE: After 50 hours of use, remove the inlet filter, take apart and clean filter screen.
DO NOT ALLOW MACHINE TO REMAIN STATIONARY
ON SOFT SURFACES SUCH AS WOOD.
Caution: Striking any raised obstacle during operation will damage machine. If contact does occur and results in vibration when operating machine, STOP and replace spray bar. Continued operation could result in serious injury or damage to machine.
STORAGE NOTE
When storing the FSC for a few weeks or months, it is best to drain as much water as possible.
Disconnect the FSC from the pump and stand the handle up. Clamp the gun trigger open and let the water run out. Shop air can also be used at the gun inlet to force out the water.
IMPORTANT: TROUBLEHOOTING
If the flat surface cleaner rotating arm is not spinning, tilt the flat surface cleaner up so you can see the underside of the deck. If a nozzle is not spraying it is plugged and needs to be cleaned. The best way is to do this is to remove the nozzle (9/16” wrench) and tap it on a hard surface (be careful not to damage the threads). Sometimes it’s necessary to unplug the nozzle by running a thin wire through the tip.
Seal the threads before replacing the nozzle. Teflon tape can often plug a nozzle so be sure tape does not get into the nozzle flow path. A light duty liquid or paste thread sealant is the best way to seal the threads. SEE PHOTO BELOW.
General Pump
1174 Northland Drive • Mendota Heights, MN 55120
Phone: 651.686.2199 • Fax: 800.535.1745
www.generalpump.com • [email protected]
Ref 300843 Rev.F
05-16
24
21
6
7
17
13
12
22
19
18
27
26
25
9
20
8
4
5
16
1
15
10
14
2
3
Operating Pressures:
1,000 to 4,000 PSI
Max Flow: 8.0 GPM
Dimensions: 70” x 21” x 21”
Weight: 21 lbs.
11
ITEM
NO.
1
PART
DESCRIPTION QTY.
NO.
2660045 Deck, GP, 20” 1
4
5
6
2
3
2530009 Arm, Rotary, Assy., 20”
2630010 Plate, Retaining
2540023 Collar, Split
2540020 Block, Handle
2660047 Grip, Handle
7
8
9
2660046
2200055
2200054
Plug, Handle
SHCS, M8 X 1.25 X 30, SST
SHCS, M8 x 1.25 x 25, SST
10 2200053 NUT, M8X1.25
11 2660059 Brush Assy., 20”
12 D10009 Plug, 3/9 x 3/8-M
13 D10004 Coupler, 3/8 x 3/8-M
14 2200047 Bolt, M6
1
4
1
4
1
1
1
8
1
2
1
1
1
ITEM PART
DESCRIPTION QTY.
NO.
NO.
15 2203406 Washer, M6 8
16 2202010 Pin, 55mm, w/Ring, SST
17 2200058 HHCS, M6 X 1 X 60
18 2200026 NUT, NYLOK, M6
19 2200018 Washer, M6
20 2203507 Washer, M6, SST, Lock
21 DCG4000FSC Gun, Flat Surface Cleaner 1
22 2702000 Hose, 20” 1
23 2540021 Handle, Lower 1
24 2540037 Handle, Upper
25 2103220 Swivel
26 D40014 FILTER, IN-LINE, BRASS
27 2103016 Nozzle
1
2
1
1
2
4
1
2
2
Ref 300843 Rev. F
05-16