Schluter Shower System Installation Handbook
The Schluter® Shower System is a bonded waterproofing system that is designed for tiled showers, steam showers, steam rooms, and bathtub surrounds. It is an integrated family of products that creates a sealed system, making shower installation easier than ever.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Schluter
®
-Shower System Installation Handbook 2016
Bonded Waterproofing System for Tiled Showers,
Steam Showers, Steam Rooms, and Bathtub Surrounds
3
Schluter ® -Shower System
Bonded Waterproofing System for Tiled Showers,
Steam Showers, Steam Rooms, and Bathtub Surrounds
Ceramic and stone tiles are durable, easy to maintain, and hygienic, representing the ideal surface coverings, particularly in wet areas such as showers and bathtub surrounds. These coverings are not inherently waterproof, however, and must be installed in conjunction with a waterproofing system that effectively manages moisture to protect moisture-sensitive building materials and control mold growth.
3
1
4
1
2
3
4
Pre-slope
Weep holes
Pan liner
Mortar bed
2
The Traditional Tiled Shower System
The traditional method for installing tiled showers is time and labor intensive and creates a “water in/water out” system. First, a mortar bed is sloped to the weep holes in the drain. The waterproofing membrane, called a pan liner, is placed over this “pre-slope” and clamped into the drain. Pan liners do not allow for the direct application of ceramic or stone tile. Thus, another mortar bed must be installed to provide load distribution and a bonding surface for the floor tile. Finally, a moisture barrier typically must be included behind the solid backing on the walls
(e.g., mortar, cement backerboard, etc.) and lapped over the pan liner to protect the wall cavities from moisture penetration and divert that moisture into the pan.
Contrary to popular belief, the tile covering itself is not waterproof. Moisture will infiltrate the mortar bed and solid backing on the walls. This moisture must percolate through the mortar bed to the sloped pan liner and exit through the weep holes in the drain. With regular use of the shower the mortar bed can remain saturated, particularly if pre-slope installation is ignored or the weep holes become clogged, thus increasing the potential for efflorescence and mold growth within the system.
1
3
2
1
2
3
Schluter ® -KERDI-DRAIN
Sloped mortar bed or
Schluter ® -KERDI-SHOWER-ST prefabricated foam tray
Schluter ® -KERDI waterproofing membrane
Schluter
®
-Shower System
The Schluter ® -Shower System is an integrated family of products that creates a
“sealed” system. First, the Schluter ® -KERDI-DRAIN is installed in conjunction with either a sloped mortar bed or the Schluter ® -KERDI-SHOWER-ST prefabricated foam tray. The KERDI-DRAIN provides a simple and secure connection to the Schluter ® -KERDI waterproofing membrane at the top of the assembly via the unique integrated bonding flange. Unlike shower pan liners in traditional assemblies, KERDI is a bonded waterproofing membrane that allows for the direct application of tile with thin-set mortar. KERDI is bonded to the mortar bed or tray and the surface of the KERDI-DRAIN’s integrated bonding flange. In addition, KERDI is installed over the solid backing (e.g., gypsum board, cement backerboard, etc.) on walls, creating a fully waterproof and vaportight enclosure.
The resulting assembly provides superior moisture management as it does not permit moisture to penetrate into the mortar bed or solid backing, allowing the assembly to dry completely between uses. The integrated Schluter
®
-Shower
System eliminates leaks, reduces the potential for efflorescence and mold growth in the system, and dramatically reduces total installation time to ensure success and make shower installation easier than ever.
Schluter
®
-Systems’ written installation instructions shall have precedence over referenced industry
standard guidelines and installation procedures insofar as referenced information may contain overlapping or conflicting requirements. Type, thickness, and format of the tile or stone surface covering must be suitable for the intended application.
CONTENTS
SHOWER SELECTION GUIDE
SHOWER ASSEMBLY
4
6
Schluter ® -KERDI waterproofing membrane
8
Schluter ® -KERDI-BOARD waterproof building panel
10 Barrier-free showers
STEAM SHOWER ASSEMBLY
STEAM ROOM ASSEMBLY
INSTALLATION
BATHTUB SURROUND
12
Schluter ® -KERDI waterproofing membrane
14
Schluter ® -KERDI-BOARD waterproof building panel
16
Schluter ® -KERDI-DS waterproofing membrane
18 Bathtub surround assembly
20 Walls and ceilings
21
Schluter ® -KERDI-BOARD-SN shower niche
22 Shower base with
Schluter ® -KERDI-DRAIN
26 Shower base with
Schluter ® -KERDI-LINE
32 Bathtub surround
34 Accessibility and style
35 Security and utility
BARRIER-FREE SHOWERS
THE WATERPROOF BATHROOM
PROFILES
THIN-SET FACTS
TESTING, LISTINGS,
& APPROVALS
MOLD
VAPOR
PRODUCT & ORDERING INFO
WARRANTY
36 Details make the difference
37 Discussion on thin-set mortar types to be used
with
Schluter ® -KERDI
38 Products and system evaluation
39 The importance of mold control
40 The importance of water vapor management
41
51
SHOWER SELECTION GUIDE
Beautiful, durable, functional
The Schluter ® -Shower System is versatile to fit the needs of the installer. The Shower Selection Guide describes the available options to help you determine which products will best fit your shower application.
KERDI
KERDI-DRAIN
KERDI-BOARD
Waterproofing options
Schluter ® -KERDI waterproofing membrane over solid backing
• Thickness: 8 mil (0.2 mm)
• Pliable, easy to install, and guarantees uniform thickness for reliable performance
• Suitable for use in showers, bathtub surrounds, and intermittent-use steam showers
Schluter ® -KERDI-DS waterproofing membrane over solid backing
• Thickness: 20 mil (0.5 mm)
• Provides improved vapor permeance as compared to KERDI
• Suitable for use in continuous-use steam rooms
Schluter ® -KERDI-BOARD waterproof building panel
• Lightweight, easy to cut and install XPS foam panel
• Combines substrate installation and waterproofing
• Suitable for use in showers, bathtub surrounds, and intermittent-use steam showers
Drain options
• Integrated bonding flange ensures waterproof connection at top of assembly
• Can be installed with prefabricated foam shower trays or mortar bases
• Simple connection to standard drain outlets for new construction or renovation
• Grate assemblies accommodate a wide range of tile thicknesses
Schluter ® -KERDI-DRAIN
• Fully adjustable square grate assemblies minimize and simplify tile cuts
• Available with 2" or 3" (50 mm or 75 mm) outlets
• Adaptor kits allow for conversion of existing clamping ring drain to KERDI-DRAIN
Schluter ® -KERDI-LINE
• Accommodates single-plane slope and large-format tile installation
• Can be installed adjacent to walls or at intermediate locations
KERDI-LINE
KERDI-SHOWER-ST Mortar Bed
Shower base options
Schluter prefabricated shower trays
• Lightweight, easy to install
• Reduces installation time
• Available in a variety of formats to suit your installation needs
• Can be cut to size or extended using dry pack mortar
Portland cement mortar bed
• Base can be built for custom shower, fits any shape
• Especially suited for off-set drain placement
4 SHOWER SELECTION GUIDE
KERDI-BOARD
KERDI-BOARD-SB
KERDI-BOARD
KERDI-BOARD-SC
KERDI-SHOWER-SC
Built-up Curb
Curb options
Schluter ® -KERDI-BOARD-SC curb
• Waterproof and ready for tile
• Lightweight, stable, and load bearing
• Can be cut to length
• Can be used with Schluter prefabricated shower trays or mortar base applications
Schluter ® -KERDI-SHOWER-SC curb
• Preformed, lightweight and easy to install
• Can be cut to length
• Can be used with Schluter prefabricated shower trays or mortar base applications
Schluter ® -KERDI-BOARD curb
• Customizable to fit any application
• Build as desired (e.g., length, width, height)
• Can be installed over various materials (e.g., masonry, wood)
Built-up curb
• Customizable to fit any application
• Can be built as desired (e.g., length, width, height)
Bench options
Schluter ® -KERDI-BOARD-SB bench
• Waterproof and ready for tile
• Lightweight, stable, and load bearing
• Available in triangular and rectangular shapes in various sizes
Schluter ® -KERDI-BOARD bench
• Customizable to fit any application, can be built as desired
• Combines substrate installation and waterproofing
Built-up bench
• Customizable to fit any application
• Can be built as desired (e.g., length, width, height)
Shower niche
Schluter ® -KERDI-BOARD-SN shower niche
• Prefabricated shower niche made of KERDI-BOARD
• Preformed, lightweight, easy to install
• Various sizes available
SHOWER SELECTION GUIDE 5
SHOWER ASSEMBLY
Showers – Ceramic or stone tile
Schluter
®
-KERDI waterproofing membrane
K-SH-K-16
6
7
2
3
1
4
12
5
11
9 a
8 a
10
6
5
2
7
3
6
6
4
9 b
8 b
5
12
11
10
1
5
1
2
3
4
5
6
7
Ceramic or stone tile
Unmodified thin-set mortar
Schluter ® -KERDI waterproofing membrane
Schluter ® -KERDI-BAND waterproofing strips
Schluter ® -KERDI-KERECK-F waterproofing corners
Schluter ® -KERDI-SEAL-PS/-MV seals or Schluter ® -KERDI-FIX sealant and bonding compound
Solid backing
8
9
Drain: a.
Schluter b.
Schluter
®
®
-KERDI-DRAIN
-KERDI-LINE
Base: a.
Schluter ® -KERDI-SHOWER-ST b.
Schluter ® -KERDI-SHOWER-L/-LS
Alternative (not shown):
• Mortar bed
12 Schluter ® -DILEX profile (optional)
Bench (not shown):
• Schluter ® -KERDI-BOARD-SB bench (optional)
• Schluter ® -KERDI-BOARD bench (optional)
Niche (not shown):
• Schluter ® -KERDI-BOARD-SN niche (optional)
10 Schluter curb
® -KERDI-BOARD-SC
Alternatives (not shown):
• Schluter ® curb
-KERDI-SHOWER-SC
• Schluter ® -KERDI-BOARD waterproof building panel
• Built-up curb
11 Wood or concrete subfloor
6 SHOWER ASSEMBLY — Schluter
®
-KERDI waterproofing membrane
Showers – Ceramic or stone tile
Schluter
®
-KERDI waterproofing membrane
K-SH-K-16
Areas of Application
Interior showers.
Over wood or concrete subfloors.
Areas requiring disabled access/barrier-free applications; see detail
K-SHBF on page 10.
Substrate Preparation
Verify that subfloor panels and solid backing are properly fastened to framing members.
Any leveling of the subfloor must be done prior to installing
KERDI-SHOWER-ST/-L/-LS/-SC/-SR and KERDI-BOARD-SC/-SB.
Limitations
Certain glass tiles may not be compatible with bonded waterproof membranes and/or may require special setting materials. Consult glass tile manufacturer and Schluter ® -Systems for more information.
Certain moisture sensitive stones, e.g., green marble, or resin-backed tiles may not be appropriate for use in wet areas such as showers or may require special setting materials. Consult stone supplier and
Schluter ® -Systems for more information.
Do not use sawn lumber curbs on concrete subfloors subject to moisture migration.
Solid Backing Materials
Gypsum wallboard – ASTM C1396/C1396M
Cementitious backer unit – ANSI A118.9 or ASTM C1325
Fiber-cement underlayment – ASTM C1288
Fiber-reinforced water-resistant gypsum
backerboard/underlayment – ASTM C1278
Coated glass mat water-resistant gypsum backerboard – ASTM C1178
Portland cement mortar – ANSI A108.1B
Concrete
Masonry
Requirements
Plywood, OSB, or concrete subfloor must be clean, even, and load bearing.
Solid backing – gypsum wallboard, cementitious backer unit, fiber-cement underlayment, fiber-reinforced water-resistant gypsum backerboard/underlayment, coated glass mat water-resistant gypsum backerboard, Portland cement mortar bed, concrete, or masonry.
Base – KERDI-SHOWER-ST/-L/-LS or Portland cement mortar bed.
Curb – KERDI-BOARD-SC, KERDI-SHOWER-SC, KERDI-BOARD, concrete, masonry block, or sawn lumber sheathed with solid backing
(see above).
Bench – KERDI-BOARD-SB, KERDI-BOARD, concrete, masonry block, or sawn lumber sheathed with solid backing (see above).
KERDI-DRAIN/-LINE shall be properly supported.
KERDI-DRAIN/-LINE shall be connected to the waste line; use ABS cement for ABS drains, PVC cement for PVC drains, a no-hub coupling for stainless steel drains with no-hub outlets, and thread sealing compound or tape for stainless steel drains with threaded outlets.
KERDI waterproofing membrane shall be installed up to the height of the showerhead at minimum.
Any protrusions through the KERDI membrane (e.g., showerhead, mixing valve, etc.) must be treated with KERDI-SEAL-PS/-MV seals, KERDI-FIX or suitable sealant.
When using the stainless steel KERDI-DRAIN bonding flange, use
KERDI-FIX to bond KERDI to the drain.
Setting and Grouting Materials
Unmodified thin-set mortar – ANSI A118.1
Grout – ANSI A118.3, A118.6, A118.7
Installation Specifications
Solid backing panels – follow manufacturer’s instructions
Portland cement mortar bed – ANSI A108.1B
Tile – ANSI A108.5
Grout – ANSI A108.6, A108.10
Other Considerations
When KERDI-SHOWER-ST/-L/-LS tray dimensions do not match the dimensions of the shower compartment, the tray may be cut or extended with dry pack mortar.
When KERDI and tile are installed on the ceiling, the solid backing and fasteners must be able to support the load of the tile and setting and grouting materials.
A water test is recommended before setting tile to verify a successful installation. Wait 24 hours minimum after the membrane installation is complete to allow for final set of thin-set mortar and ensure waterproof performance at seams and connections.
Schluter ® -Systems profiles may be used to finish and protect outside corners and eliminate the use of sealant at inside corners; see page 36.
Schluter ® -SHOWERPROFILE-S/-R profiles eliminate the need for cutting wedges of tile by covering the exposed wall area where the floor slopes to KERDI-LINE.
SHOWER ASSEMBLY — Schluter
®
-KERDI waterproofing membrane 7
SHOWER ASSEMBLY
Showers – Ceramic or stone tile
Schluter
®
-KERDI-BOARD waterproof building panel
K-SH-KB-16
6
5
4
8
1
8
2
5 8
6
4
8
1
2
7
12
9 a
10 a
13
11
3
7
10 b
9 b
7
12
13
11
3
7
1 Ceramic or stone tile 9 Drain: 12 Wood or concrete subfloor
2 Unmodified thin-set mortar
Schluter ® -KERDI-BOARD waterproof building panel a.
Schluter ® -KERDI-DRAIN b.
Schluter ® -KERDI-LINE
13 Schluter ® -DILEX profile (optional)
3
4
Schluter ® -KERDI waterproofing membrane 10 Base: a.
Schluter ® -KERDI-SHOWER-ST b.
Schluter ® -KERDI-SHOWER-L/-LS
Bench (not shown):
• Schluter ® -KERDI-BOARD-SB bench (optional)
• Schluter ® -KERDI-BOARD bench (optional)
5 Schluter washers
® -KERDI-BOARD-ZT Alternative (not shown):
• Mortar bed
6
7
8
Schluter ® -KERDI-BAND waterproofing strips
Schluter ® -KERDI-KERECK-F waterproofing corners
Schluter seals or
® -KERDI-SEAL-PS/-MV
Schluter ® -KERDI-FIX sealant and bonding compound
11 Schluter curb
® -KERDI-BOARD-SC
Alternatives (not shown):
• Schluter ® curb
-KERDI-SHOWER-SC
• Schluter ® -KERDI-BOARD waterproofing panel
• Built-up curb
8 SHOWER ASSEMBLY — Schluter
®
-KERDI-BOARD waterproof building panel
Niche (not shown):
• Schluter ® -KERDI-BOARD-SN niche (optional)
Showers – Ceramic or stone tile
Schluter
®
-KERDI-BOARD waterproof building panel
K-SH-KB-16
Areas of Application
Interior showers.
Over wood or concrete subfloors.
Areas requiring disabled access/barrier-free applications; see detail
K-SHBF on page 10.
Substrate Preparation
Verify that subfloor panels are properly fastened to framing members.
Any leveling of the subfloor must be done prior to installing
KERDI-SHOWER-ST/-L/-LS/-SC/-SR or KERDI-BOARD-SC/-SB.
Limitations
Certain glass tiles may not be compatible with bonded waterproof membranes and/or may require special setting materials. Consult glass tile manufacturer and Schluter ® -Systems for more information.
Certain moisture-sensitive stones, e.g., green marble, or resin-backed tiles, may not be appropriate for use in wet areas such as showers or may require special setting materials. Consult stone supplier and
Schluter ® -Systems for more information.
Do not use sawn lumber curbs on concrete subfloors subject to moisture migration.
Solid Backing Materials
Gypsum wallboard – ASTM C1396/C1396M
Cementitious backer unit – ANSI A118.9 or ASTM C1325
Fiber-cement underlayment – ASTM C1288
Fiber-reinforced water-resistant gypsum backerboard/underlayment –
ASTM C1278
Coated glass mat water-resistant gypsum backerboard – ASTM C1178
Portland cement mortar – ANSI A108.1B
Concrete
Masonry
Requirements
Plywood, OSB, or concrete subfloor must be clean, even, and load bearing.
Base – KERDI-SHOWER-ST/-L/-LS or Portland cement mortar bed.
Curb – KERDI-BOARD-SC, KERDI-SHOWER-SC, KERDI-BOARD, concrete, masonry block, or sawn lumber sheathed with solid backing
(see below).
Bench – KERDI-BOARD-SB, KERDI-BOARD, concrete, masonry block, or sawn lumber sheathed with solid backing (see below).
Solid backing – gypsum wallboard, cementitious backer unit, fibercement underlayment, fiber-reinforced water-resistant gypsum backerboard/underlayment, coated glass mat water-resistant gypsum backerboard, Portland cement mortar bed, concrete, or masonry.
KERDI-DRAIN/-LINE shall be properly supported.
KERDI-DRAIN/-LINE shall be connected to the waste line; use ABS cement for ABS drains, PVC cement for PVC drains, a no-hub coupling for stainless steel drains with no-hub outlets, and thread sealing compound or tape for stainless steel drains with threaded outlets.
Minimum KERDI-BOARD thickness – 1/2" (12.5 mm) for studs spaced at
16" (40.6 cm) o.c. and 3/4" (19 mm) for studs spaced at 24" (61.0 cm) o.c.
KERDI-BOARD shall be fastened to wood or metal framing with appropriate screws (i.e., coarse thread wood screw for wood studs and self-tapping for metal studs) and corresponding KERDI-BOARD-ZT washers. Screws must reach a depth of at least 3/4" (20 mm) in wood studs and 3/8" (10 mm) in metal studs. Maximum allowable on-center fastener spacing is 12" (30 cm) for walls and 6" (15 cm) for ceilings.
KERDI-BOARD shall be installed up to the height of the showerhead at minimum.
Any protrusions through the KERDI-BOARD (e.g., showerhead, mixing valve, etc.) must be treated with KERDI-SEAL-PS/-MV seals, KERDI-FIX or suitable sealant.
When using the stainless steel KERDI-DRAIN bonding flange, use
KERDI-FIX to bond KERDI to the drain.
Setting and Grouting Materials
Unmodified thin-set mortar – ANSI A118.1
Grout – ANSI A118.3, A118.6, A118.7
Installation Specifications
Portland cement mortar bed – ANSI A108.1B
Tile – ANSI A108.5
Grout – ANSI A108.6, A108.10
Other Considerations
When KERDI-SHOWER-ST/-L/-LS tray dimensions do not match the dimensions of the shower compartment, the tray may be cut or extended with dry pack mortar.
Shower grab bars must be anchored in the structure or solid blocking behind KERDI-BOARD.
When KERDI-BOARD and tile are installed on the ceiling, the fasteners must be able to support the load of the tile and setting and grouting materials.
A water test is recommended before setting tile to verify a successful installation. Wait 24 hours minimum after the membrane installation is complete to allow for final set of thin-set mortar and ensure waterproof performance at seams and connections.
Schluter ® -Systems profiles may be used to finish and protect outside corners and eliminate the use of sealant at inside corners; see page 36.
Schluter ® -SHOWERPROFILE-S/-R profiles eliminate the need for cutting wedges of tile by covering the exposed wall area where the floor slopes to KERDI-LINE.
SHOWER ASSEMBLY — Schluter
®
-KERDI-BOARD waterproof building panel 9
SHOWER ASSEMBLY
Barrier-free Showers – Ceramic or stone tile
Schluter
®
-KERDI waterproofing membrane or
Schluter
®
-KERDI-BOARD waterproof building panel
K-SHBF-16
2
3 1
8
8
5
4
8
6
8
1
2
6
15
14
7
9 a
10 a
11
12 a
3
13b
9 b
10 b
13
7
15
12 b
6
13a
1
2
3
4
5
6
7
8
Ceramic or stone tile
Unmodified thin-set mortar
Schluter ® -KERDI waterproofing membrane
Schluter ® -KERDI-BOARD waterproof building panel
Schluter ® -KERDI-BOARD-ZT washers
Schluter ® -KERDI-BAND waterproofing strips
Schluter ® -KERDI-KERECK-F waterproofing corners
Schluter ® -KERDI-SEAL-PS/-MV seals or Schluter ® -KERDI-FIX sealant and bonding compound
9
10
11
12
10 SHOWER ASSEMBLY — Barrier-free
Drain: a.
Schluter ® -KERDI-DRAIN b.
Schluter ® -KERDI-LINE
Base: a.
Schluter ® -KERDI-SHOWER-ST b.
Schluter ® -KERDI-SHOWER-L/-LS
Alternative (not shown):
• Mortar bed
13 Uncoupling membrane: a.
Schluter ® -DITRA uncoupling membrane b.
Schluter ® -DITRA-HEAT electric floor warming and uncoupling membrane
Alternative (not shown):
• Schluter ® -KERDI waterproofing membrane
14 Wood or concrete subfloor
15 Schluter ® -DILEX profile (optional) Schluter ramp
® -KERDI-SHOWER-SR
Alternative (not shown):
• Mortar ramp
Shower profiles: a.
Schluter ® -SHOWERPROFILE-WS/-WSC b.
Schluter ® -SHOWERPROFILE-WSK/-WSL
Bench (not shown):
• Schluter ® -KERDI-BOARD-SB bench (optional)
• Schluter ® -KERDI-BOARD bench (optional)
Niche (not shown):
• Schluter ® -KERDI-BOARD-SN niche (optional)
Barrier-Free Showers – Ceramic or stone tile
Schluter
®
-KERDI waterproofing membrane or
Schluter
®
-KERDI-BOARD waterproof building panel
K-SHBF-16
Areas of Application
Interior showers with barrier-free access.
Over wood or concrete subfloors.
Limitations
Certain glass tiles may not be compatible with bonded waterproof membranes and/or may require special setting materials. Consult glass tile manufacturer and Schluter ® -Systems for more information.
Certain moisture sensitive stones, e.g., green marble, or resin-backed tiles may not be appropriate for use in wet areas such as steam showers or may require special setting materials. Consult stone supplier and
Schluter ® -Systems for more information.
Fiber-cement underlayment – ASTM C1288
Fiber-reinforced water-resistant gypsum
backerboard/underlayment – ASTM C1278
Coated glass mat water-resistant gypsum backerboard – ASTM C1178
Portland cement mortar – ANSI A108.1B
Concrete
Masonry
Setting and Grouting Materials
Unmodified thin-set mortar – ANSI A118.1
Grout – ANSI A118.3, A118.6, A118.7
Requirements
Plywood, OSB, or concrete subfloor must be clean, even, and load bearing.
Recessing the floor of a bathroom must be done in a way that preserves the structural integrity and safety of the construction. This may require the services of a qualified design professional (e.g., architect, engineer, etc.).
Solid backing – gypsum wallboard, cementitious backer unit, fibercement underlayment, fiber-reinforced water-resistant gypsum backerboard/underlayment, coated glass mat water-resistant gypsum backerboard, Portland cement mortar bed, concrete, or masonry.
Base – KERDI-SHOWER-ST/-L/-LS or Portland cement mortar bed.
Ramp – KERDI-SHOWER-SR or Portland cement mortar bed.
Bench –KERDI-BOARD-SB, KERDI-BOARD, concrete, masonry block, or sawn lumber sheathed with solid backing (see above).
KERDI-DRAIN/-LINE shall be properly supported.
KERDI-DRAIN/-LINE shall be connected to the waste line; use ABS cement for ABS drains, PVC cement for PVC drains, a no-hub coupling for stainless steel drains with no-hub outlets, and thread sealing compound or tape for stainless steel drains with threaded outlets.
Minimum KERDI-BOARD thickness – 1/2" (12.5 mm) for studs spaced at
16" (40.6 cm) o.c. and 3/4" (19 mm) for studs spaced at 24" (61.0 cm) o.c.
KERDI-BOARD shall be fastened to wood or metal framing with appropriate screws (i.e., coarse thread wood screw for wood studs and self-tapping for metal studs) and corresponding KERDI-BOARD-ZT washers. Screws must reach a depth of at least 3/4" (20 mm) in wood studs and 3/8" (10 mm) in metal studs. Maximum allowable on-center fastener spacing is 12" (30 cm) for walls and 6" (15 cm) for ceilings.
KERDI or KERDI-BOARD shall be installed up to the height of the showerhead at minimum.
KERDI, DITRA or DITRA-HEAT shall be installed in all floor areas subject to water exposure (i.e., wet area and drying area). Floor/wall connections shall be sealed with KERDI-BAND.
Any protrusions through the KERDI or KERDI-BOARD (e.g., showerhead, mixing valve, etc.) must be treated with KERDI-SEAL-PS/-MV seals,
KERDI-FIX or suitable sealant.
When using the stainless steel KERDI-DRAIN bonding flange, use
KERDI-FIX to bond KERDI to the drain.
Substrate Preparation
Verify that subfloor panels and solid backing are properly fastened to framing members.
Any leveling of the subfloor must be done prior to installing
KERDI-SHOWER-ST/-L/-LS/-SR and KERDI-BOARD-SB prefabricated substrates.
Solid Backing Materials
Gypsum wallboard – ASTM C1396/C1396M
Cementitious backer unit – ANSI A118.9 or ASTM C1325
Installation Specifications
Solid backing panels – follow manufacturer’s directions
Portland cement mortar bed – ANSI A108.1B
Tile – ANSI A108.5
Grout – ANSI A108.6, A108.10
Other Considerations
Barrier-free tiled showers rely on the slope of the floor to effectively contain water in the immediate shower area and direct water to the drain.
Given the wide range of potential configurations, it isn’t possible to address them all in this Handbook.
Waterproofing must be installed in all areas subject to water exposure.
Install KERDI over mortar beds and Schluter ® prefabricated EPS foam substrates. Use the DITRA or DITRA-HEAT uncoupling membrane over plywood/OSB or concrete subfloors. All seams are sealed using KERDI-
BAND. Please refer to the Schluter ® -DITRA or Schluter ® -DITRA-HEAT
Installation Handbooks for complete details and warranty criteria.
If KERDI-LINE is placed at shower entrance, it is recommended that grate assembly A or D is chosen and that the drainage openings span the maximum width of the entrance to limit potential overflow; secondary drainage (e.g., KERDI-DRAIN) may be required in the drying area.
Schluter ® -SHOWERPROFILE-WS/-WSK system profiles can be used to form a splashguard at the entrance of curbless showers. See page 31.
Various building codes and other sources, such as the Americans with Disabilities Act, include specific requirements for disabled access in public buildings and must be consulted when applicable. Areas of interest may include degree of slope, clearance, and supporting structures such as grab bars.
Shower grab bars must be anchored in the structure or solid blocking behind KERDI-BOARD.
When KERDI-SHOWER-ST/-L/-LS tray dimensions do not match the dimensions of the shower compartment, the tray may be cut or extended with dry pack mortar.
When KERDI or KERDI-BOARD and tile are installed on the ceiling, the solid backing and fasteners must be able to support the load of the tile and setting and grouting materials.
A water test is recommended before setting tile to verify a successful installation. Wait 24 hours minimum after the membrane installation is complete to allow for final set of thin-set mortar and ensure waterproof performance at seams and connections. A temporary dam (e.g., a 2x4 and silicone sealant, plastic sheeting and sand, etc.) must be provided at the threshold to perform the water test.
Schluter ® -Systems profiles may be used to finish and protect outside corners and eliminate the use of sealant at inside corners; see page 36.
Schluter ® -SHOWERPROFILE-S/-R profiles eliminate the need for cutting wedges of tile by covering the exposed wall area where the floor slopes to KERDI-LINE.
SHOWER ASSEMBLY — Barrier-free 11
STEAM SHOWER ASSEMBLY
Intermittent Use Steam Showers – Ceramic or stone tile
Schluter
®
-KERDI waterproofing membrane
K-SSH-K-16
7
4
12
3
1
2
6
6
7
4
6
12
3
2
6
1
4
12
11
5
8a
9a
10
6
4
6
8b
9b
11
5
12
10
1
2
3
4
5
6
7
Ceramic or stone tile
Unmodified thin-set mortar
Schluter ® -KERDI waterproofing membrane
Schluter ® -KERDI-BAND waterproofing strips
Schluter ® -KERDI-KERECK-F waterproofing corners
Schluter ® -KERDI-SEAL-PS/-MV seals or Schluter ® -KERDI-FIX sealant and bonding compound
Solid backing
8 Drain: a.
Schluter ® -KERDI-DRAIN b.
Schluter ® -KERDI-LINE
9 Base: a.
Schluter ® -KERDI-SHOWER-ST b.
Schluter ® -KERDI-SHOWER-L/-LS
Alternative (not shown):
• Mortar bed
10 Schluter ® -KERDI-BOARD-SC curb
Alternatives (not shown):
• Schluter ® curb
-KERDI-SHOWER-SC
• Schluter ® -KERDI-BOARD waterproofing panel
• Built-up curb
11 Wood or concrete subfloor
12 Schluter ® -DILEX profile (optional)
Bench (not shown):
• Schluter ® -KERDI-BOARD-SB bench (optional)
• Schluter ® -KERDI-BOARD bench (optional)
Niche (not shown):
• Schluter ® -KERDI-BOARD-SN niche (optional)
12 STEAM SHOWER ASSEMBLY — Schluter
®
-KERDI waterproofing membrane
Intermittent Use Steam Showers – Ceramic or stone tile
Schluter
®
-KERDI waterproofing membrane
K-SSH-K-16
Areas of Application
Interior intermittent use steam showers (e.g., residential applications).
Over wood or concrete subfloors.
Areas requiring disabled access/barrier-free applications; see detail
K-SHBF on page 10.
Limitations
Not intended for continuous use steam rooms (e.g., applications in spas, fitness centers, etc.); see detail K-SR on page 16.
Certain glass tiles may not be compatible with bonded waterproof membranes and/or may require special setting materials. Consult glass tile manufacturer and Schluter ® -Systems for more information.
Certain moisture sensitive stones, e.g., green marble, or resin-backed tiles may not be appropriate for use in wet areas such as steam showers or may require special setting materials. Consult stone supplier and
Schluter ® -Systems for more information.
Do not use sawn lumber curbs on concrete subfloors subject to moisture migration.
Substrate Preparation
Verify that subfloor panels and solid backing are properly fastened to framing members.
Any leveling of the subfloor must be done prior to installing
KERDI-SHOWER-ST/-L/-LS/-SC/-SR and KERDI-BOARD-SC/-SB.
Solid Backing Materials
Gypsum wallboard – ASTM C1396/C1396M
Cementitious backer unit – ANSI A118.9 or ASTM C1325
Fiber-cement underlayment – ASTM C1288
Fiber-reinforced water-resistant gypsum
backerboard/underlayment – ASTM C1278
Coated glass mat water-resistant gypsum backerboard – ASTM C1178
Portland cement mortar – ANSI A108.1B
Concrete
Masonry
Requirements
Plywood, OSB, or concrete subfloor must be clean, even, and load bearing.
Provide insulation in wall and ceiling cavities to reduce moisture condensation on the tiled surface.
Solid backing – gypsum wallboard, cementitious backer unit, fibercement underlayment, fiber-reinforced water-resistant gypsum backerboard/underlayment, coated glass mat water-resistant gypsum backerboard, Portland cement mortar bed, concrete, or masonry.
Base – KERDI-SHOWER-ST/-L/-LS or Portland cement mortar bed.
Curb – KERDI-BOARD-SC, KERDI-SHOWER-SC, KERDI-BOARD, concrete, masonry block, or sawn lumber sheathed with solid backing
(see above).
Bench – KERDI-BOARD-SB, KERDI-BOARD, concrete, masonry block, or sawn lumber sheathed with solid backing (see above)
KERDI-DRAIN/-LINE shall be properly supported.
KERDI-DRAIN/-LINE shall be connected to the waste line; use ABS cement for ABS drains, PVC cement for PVC drains, a no-hub coupling for stainless steel drains with no-hub outlets, and thread sealing compound or tape for stainless steel drains with threaded outlets.
Slope ceilings 2" (50 mm) per foot minimum to avoid condensation from dripping onto occupants (may be sloped to center to minimize rundown on walls).
Install KERDI waterproofing membrane on all surfaces, including the ceiling.
Any protrusions through the KERDI membrane (e.g., showerhead, mixing valve, steam inlet, etc.) must be treated with KERDI-SEAL-PS/-MV seals,
KERDI-FIX or suitable sealant.
When using the stainless steel KERDI-DRAIN integrated bonding flange, use KERDI-FIX to bond KERDI to the drain.
Movement joints shall be provided at all changes in plane, including floor/ wall, wall/wall, and wall/ceiling transitions. Schluter prefabricated movement joint profiles (e.g., DILEX-EKE) provide a maintenance-free alternative to sealant; see page 36.
® -Systems
Setting and Grouting Materials
Unmodified thin-set mortar – ANSI A118.1
Grout – ANSI A118.3, A118.6, A118.7
Installation Specifications
Solid backing panels – follow manufacturer’s directions
Portland cement mortar bed – ANSI A108.1B
Tile – ANSI A108.5
Grout – ANSI A108.6, A108.10
Other Considerations
When KERDI-SHOWER-ST/-L/-LS tray dimensions do not match the dimensions of the shower compartment, the tray may be cut or extended with dry pack mortar.
When KERDI and tile are installed on the ceiling, the solid backing and fasteners must be able to support the load of the tile and setting and grouting materials.
A water test is recommended before setting tile to verify a successful installation. Wait 24 hours minimum after the membrane installation is complete to allow for final set of thin-set mortar and ensure waterproof performance at seams and connections.
Schluter ® -Systems profiles may be used to finish and protect outside corners and eliminate the use of sealant at inside corners; see page 36.
Schluter ® -SHOWERPROFILE-S/-R profiles eliminate the need for cutting wedges of tile by covering the exposed wall area where the floor slopes to KERDI-LINE.
STEAM SHOWER ASSEMBLY — Schluter
®
-KERDI waterproofing membrane 13
STEAM SHOWER ASSEMBLY
Intermittent Use Steam Showers – Ceramic or stone tile
Schluter
®
-KERDI-BOARD waterproof building panel
K-SSH-KB-16
6
5
4
13
1
8
2
8
5
4
8
13
1
6
8
2
12
7
10 a
9 a
3
8
11
8
9 b
10 b
12
11
3
7
1
2
3
4
5
6
7
8
Ceramic or stone tile
Unmodified thin-set mortar
Schluter ® -KERDI waterproofing membrane
Schluter ® -KERDI-BOARD waterproof building panel
Schluter washers
® -KERDI-BOARD-ZT
Schluter ® -KERDI-BAND waterproofing strips
Schluter ® -KERDI-KERECK-F waterproofing corners
Schluter seals or
® -KERDI-SEAL-PS/-MV
Schluter ® -KERDI-FIX sealant and bonding compound
9 Drain: a.
Schluter b.
Schluter
® -KERDI-DRAIN
® -KERDI-LINE
10 Base: a.
Schluter ® -KERDI-SHOWER-ST b.
Schluter ® -KERDI-SHOWER-L/-LS
Alternative (not shown):
• Mortar bed
11 Schluter ® -KERDI-BOARD-SC curb
Alternatives (not shown):
• Schluter ® -KERDI-SHOWER-SC curb
• Schluter ® -KERDI-BOARD waterproofing panel
• Built-up curb
12 Wood or concrete subfloor
13 Schluter ® -DILEX profile (optional)
Bench (not shown):
• Schluter ® -KERDI-BOARD-SB bench (optional)
• Schluter ® -KERDI-BOARD bench (optional)
Niche (not shown):
• Schluter ® -KERDI-BOARD-SN niche (optional)
14 STEAM SHOWER ASSEMBLY — Schluter
®
-KERDI-BOARD waterproof building panel
Intermittent Use Steam Showers – Ceramic or stone tile
Schluter
®
-KERDI-BOARD waterproof building panel
K-SSH-KB-16
Areas of Application
Interior intermittent use steam showers (e.g., residential applications).
Over wood or concrete subfloors.
Areas requiring disabled access/barrier-free applications; see detail
K-SHBF on page 10.
Substrate Preparation
Verify that subfloor panels are properly fastened to framing members.
Any leveling of the subfloor must be done prior to installing
KERDI-SHOWER-ST/-L/-LS/-SC/-SR and KERDI-BOARD-SC/-SB.
Limitations
Not intended for continuous use steam rooms (e.g., applications in spas, fitness centers, etc.); see detail K-SR on page 16.
Certain glass tiles may not be compatible with bonded waterproof membranes and/or may require special setting materials. Consult glass tile manufacturer and Schluter ® -Systems for more information.
Certain moisture sensitive stones, e.g., green marble, or resin-backed tiles may not be appropriate for use in wet areas such as steam showers or may require special setting materials. Consult stone supplier and
Schluter ® -Systems for more information.
Do not use sawn lumber curbs on concrete subfloors subject to moisture migration.
Solid Backing Materials
Gypsum wallboard – ASTM C1396/C1396M
Cementitious backer unit – ANSI A118.9 or ASTM C1325
Fiber-cement underlayment – ASTM C1288
Fiber-reinforced water-resistant gypsum
backerboard/underlayment – ASTM C1278
Coated glass mat water-resistant gypsum backerboard – ASTM C1178
Portland cement mortar – ANSI A108.1B
Concrete
Masonry
Requirements
Plywood, OSB, or concrete subfloor must be clean, even, and load bearing.
Provide insulation in wall and ceiling cavities to reduce moisture condensation on the tiled surface.
Base – KERDI-SHOWER-ST/-L/-LS or Portland cement mortar bed
Curb – KERDI-BOARD-SC, KERDI-SHOWER-SC, KERDI-BOARD, concrete, masonry block, or sawn lumber sheathed with solid backing
(see below).
Bench – KERDI-BOARD-SB, KERDI-BOARD, concrete, masonry block, or sawn lumber sheathed with solid backing (see below).
Solid backing – gypsum wallboard, cementitious backer unit, fibercement underlayment, fiber-reinforced water-resistant gypsum backerboard/underlayment, coated glass mat water-resistant gypsum backerboard, Portland cement mortar bed, concrete, or masonry.
KERDI-DRAIN/-LINE shall be properly supported.
KERDI-DRAIN/-LINE shall be connected to the waste line; use ABS cement for ABS drains, PVC cement for PVC drains, a no-hub coupling for stainless steel drains with no-hub outlets, and thread sealing compound or tape for stainless steel drains with threaded outlets.
Slope ceilings 2" (50 mm) per foot minimum to avoid condensation from dripping onto occupants (may be sloped to center to minimize rundown on walls).
Install KERDI waterproofing membrane on base and curb and
KERDI-BOARD waterproof building panel on walls and ceiling.
Minimum KERDI-BOARD thickness – 1/2" (12.5 mm) for studs spaced at
16" (40.6 cm) o.c. and 3/4" (19 mm) for studs spaced at 24" (61.0 cm) o.c.
KERDI-BOARD shall be fastened to wood or metal framing with appropriate screws (i.e., coarse thread wood screw for wood studs and self-tapping for metal studs) and corresponding KERDI-BOARD-ZT washers. Screws must reach a depth of at least 3/4" (20 mm) in wood studs and 3/8" (10 mm) in metal studs. Maximum allowable on-center fastener spacing is 12" (30 cm) for walls and 6" (15 cm) for ceilings.
Any protrusions through the KERDI-BOARD (e.g., showerhead, mixing valve, steam inlet, etc.) must be treated with KERDI-SEAL-PS/-MV seals,
KERDI-FIX or suitable sealant.
When using the stainless steel KERDI-DRAIN bonding flange, use
KERDI-FIX to bond KERDI to the integrated bonding flange.
Movement joints shall be provided at all changes in plane, including floor/ wall, wall/wall, and wall/ceiling transitions. Schluter ® -Systems prefabricated movement joint profiles (e.g., DILEX-EKE) provide a maintenance-free alternative to sealant; see page 36.
Setting and Grouting Materials
Unmodified thin-set mortar – ANSI A118.1
Grout – ANSI A118.3, A118.6, A118.7
Installation Specifications
Portland cement mortar bed – ANSI A108.1B
Tile – ANSI A108.5
Grout – ANSI A108.6, A108.10
Other Considerations
When KERDI-SHOWER-ST/-L/-LS tray dimensions do not match the dimensions of the shower compartment, the tray may be cut or extended with dry pack mortar.
Shower grab bars must be anchored in the structure or solid blocking behind KERDI-BOARD.
When KERDI-BOARD and tile are installed on the ceiling, the fasteners must be able to support the load of the tile and setting and grouting materials.
A water test is recommended before setting tile to verify a successful installation. Wait 24 hours minimum after the membrane installation is complete to allow for final set of thin-set mortar and ensure waterproof performance at seams and connections.
Schluter ® -Systems profiles may be used to finish and protect outside corners and eliminate the use of sealant at inside corners; see page 36.
Schluter ® -SHOWERPROFILE-S/-R profiles eliminate the need for cutting wedges of tile by covering the exposed wall area where the floor slopes to KERDI-LINE.
STEAM SHOWER ASSEMBLY — Schluter
®
-KERDI-BOARD waterproof building panel 15
STEAM ROOM ASSEMBLY
Continuous Use Steam Rooms – Ceramic or stone tile
Schluter
®
-KERDI-DS waterproofing membrane
K-SR-16
7
13
3
2
1
5
4
11
3
8
9
12
6
10
1
2
3
4
5
6
7
Ceramic or stone tile
Unmodified thin-set mortar
Schluter ® -KERDI-DS waterproofing membrane
Schluter ® -KERDI-BAND waterproofing strips
Schluter ® -KERDI-KERECK-F waterproofing corners
Schluter ® -KERDI-SEAL-PS seals or Schluter ® -KERDI-FIX sealant and bonding compound
Solid backing
8 Schluter ® -KERDI-DRAIN
Alternative (not shown):
• Schluter ® -KERDI-LINE
9 Mortar bed
10 Schluter curb
® -KERDI-BOARD-SC
Alternatives (not shown):
• Schluter ® curb
-KERDI-SHOWER-SC
• Schluter ® -KERDI-BOARD waterproofing panel
• Built-up curb
11 Schluter ® -KERDI-BOARD bench (optional)
Alternative (not shown):
• Schluter ® -KERDI-BOARD-SB bench (optional)
12 Wood or concrete subfloor
13 Schluter ® -DILEX profile (optional)
16 STEAM ROOM ASSEMBLY — Schluter
®
-KERDI-DS waterproofing membrane
Continuous Use Steam Rooms – Ceramic or stone tile
Schluter
®
-KERDI-DS waterproofing membrane
K-SR-16
Areas of Application
Interior continuous use steam rooms (e.g., applications in spas, fitness centers, etc.).
Over wood or concrete subfloors.
Areas requiring disabled access/barrier-free applications; see detail
K-SHBF on page 10.
Substrate Preparation
Verify that subfloor panels and solid backing are properly fastened to framing members.
Any leveling of the subfloor must be done prior to installing
KERDI-SHOWER-ST/-L/-LS/-SC/-SR and KERDI-BOARD-SC/-SB.
Limitations
Certain glass tiles may not be compatible with bonded waterproof membranes and/or may require special setting materials. Consult glass tile manufacturer and Schluter ® -Systems for more information.
Certain moisture sensitive stones, e.g., green marble, or resin-backed tiles may not be appropriate for use in wet areas such as steam showers or may require special setting materials. Consult stone supplier and
Schluter ® -Systems for more information.
When KERDI-BOARD is used, steam room must be operated in a manner such that the maximum service temperature of KERDI-BOARD
158°F (70 °C) is not exceeded.
Gypsum-based solid backing panels shall be limited in use to intermittent use steam showers (e.g., residential applications)
Do not use sawn lumber curbs on concrete subfloors subject to moisture migration.
Solid Backing Materials
KERDI-BOARD
Cementitious backer unit – ANSI A118.9 or ASTM C1325
Fiber-cement underlayment – ASTM C1288
Portland cement mortar – ANSI A108.1B
Concrete
Masonry
Setting and Grouting Materials
Unmodified thin-set mortar – ANSI A118.1
Grout – ANSI A118.3, A118.6, A118.7
Requirements
Plywood, OSB, or concrete subfloor must be clean, even, and load bearing.
Provide insulation in wall and ceiling cavities to reduce moisture condensation on the tiled surface.
Solid backing – KERDI-BOARD, cementitious backer unit, fiber-cement underlayment, Portland cement mortar bed, concrete, or masonry.
Base – Portland cement mortar bed.
Curb – KERDI-BOARD-SC, KERDI-SHOWER-SC, KERDI-BOARD, concrete, masonry block, or sawn lumber sheathed with solid backing (see above).
Bench – KERDI-BOARD, KERDI-BOARD-SB, concrete, masonry block, or sawn lumber sheathed with solid backing (see above).
KERDI-DRAIN/-LINE shall be properly supported.
KERDI-DRAIN/-LINE shall be connected to the waste line; use ABS cement for ABS drains, PVC cement for PVC drains, a no-hub coupling for stainless steel drains with no-hub outlets, and thread sealing compound or tape for stainless steel drains with threaded outlets.
Slope ceilings 2" (50 mm) per foot minimum to avoid condensation from dripping onto occupants (may be sloped to center to minimize rundown on walls).
Minimum KERDI-BOARD thickness – 1/2" (12.5 mm) for studs spaced at
16" (40.6 cm) o.c. and 3/4" (19 mm) for studs spaced at 24" (61.0 cm) o.c.
KERDI-BOARD shall be fastened to wood or metal framing with appropriate screws (i.e., coarse thread wood screw for wood studs and self-tapping for metal studs) and corresponding KERDI-BOARD-ZT washers. Screws must reach a depth of at least 3/4" (20 mm) in wood studs and 3/8" (10 mm) in metal studs. Maximum allowable on-center fastener spacing is 12" (30 cm) for walls and 6" (15 cm) for ceilings.
Install KERDI-DS waterproofing membrane on all surfaces, including the ceiling.
Any protrusions through the KERDI-DS membrane (e.g., steam inlets, lights, etc.) must be treated with KERDI-SEAL-PS, KERDI-FIX or suitable sealant.
When using the stainless steel KERDI-DRAIN bonding flange, use
KERDI-FIX to bond KERDI-DS to the drain.
Movement joints shall be provided at all changes in plane, including floor/ wall, wall/wall, and wall/ceiling transitions. Schluter ® -Systems prefabricated movement joint profiles (e.g., DILEX-EKE) provide a maintenance-free alternative to sealant; see page 36.
Installation Specifications
Solid backing panels – follow manufacturer’s directions
Portland cement mortar bed – ANSI A108.1B
Tile – ANSI A108.5
Grout – ANSI A108.6, A108.10
Other Considerations
Shower grab bars must be anchored in the structure or solid blocking behind KERDI-BOARD.
When KERDI-DS and tile are installed on the ceiling, the solid backing and fasteners must be able to support the load of the tile and setting and grouting materials.
A water test is recommended before setting tile to verify a successful installation. Wait 24 hours minimum after the membrane installation is complete to allow for final set of thin-set mortar and ensure waterproof performance at seams and connections.
Schluter ® -Systems profiles may be used to finish and protect outside corners and eliminate the use of sealant at inside corners; see page 36.
Schluter ® -SHOWERPROFILE-S/-R profiles eliminate the need for cutting wedges of tile by covering the exposed wall area where the floor slopes to KERDI-LINE.
STEAM ROOM ASSEMBLY — Schluter
®
-KERDI-DS waterproofing membrane 17
BATHTUB SURROUND
Bathtub Surround – Ceramic or stone tile
Schluter
®
-KERDI waterproofing membrane or
Schluter
®
-KERDI-BOARD waterproof building panel
K-TS-16
3a
7
2
5
7
8
7
1
10
5
3b
6
9
4
3b
7
5
7
8
7
1
10
5
3b
6
2
1 Ceramic or stone tile
2 Unmodified thin-set mortar
3 Waterproofing: a.
Schluter ® -KERDI waterproofing membrane b.
Schluter ® -KERDI-BOARD waterproof building panel
4 Schluter ® -KERDI-BOARD-ZT washers
5 Schluter ® -KERDI-BAND waterproofing strips
6 Schluter ® -KERDI-KERECK-F waterproofing corners
7 Schluter ® -KERDI-SEAL-PS/-MV seals or Schluter ® -KERDI-FIX sealant and bonding compound
8 Schluter ® -KERDI-FIX sealant and bonding compound
9 Solid backing
10 Schluter ® -DILEX profile (optional)
Niche (not shown):
• Schluter ® -KERDI-BOARD-SN niche (optional)
18 BATHTUB SURROUND
Bathtub surround – Ceramic or stone tile
Schluter
®
-KERDI waterproofing membrane or Schluter
®
-KERDI-BOARD waterproof building panel
K-TS-16
Areas of Application
Interior bathtub surrounds.
Substrate Preparation
When using KERDI waterproofing membrane, verify that solid backing is properly fastened to framing members.
Limitations
Certain glass tiles may not be compatible with bonded waterproof membranes and/or may require special setting materials. Consult glass tile manufacturer and Schluter ® -Systems for more information.
Certain moisture sensitive stones, e.g., green marble, or resin-backed tiles may not be appropriate for use in wet areas such as bathtub surrounds or may require special setting materials. Consult stone supplier and Schluter ® -Systems for more information.
Requirements
Solid backing – gypsum wallboard, cementitious backer unit, fibercement underlayment, fiber-reinforced water-resistant gypsum backerboard/underlayment, coated glass mat water-resistant gypsum backerboard, Portland cement mortar bed, concrete, or masonry.
Solid backing panels or KERDI-BOARD shall either be installed flush with the tub flange or over the tub flange leaving a minimum space of 1/4"
(6 mm) between the board and the tub deck.
Minimum KERDI-BOARD thickness – 1/2" (12.5 mm) for studs spaced at
16" (40.6 cm) o.c. and 3/4" (19 mm) for studs spaced at 24" (61 cm) o.c.
KERDI-BOARD shall be fastened to wood or metal framing with appropriate screws (i.e., coarse thread wood screw for wood studs and self-tapping for metal studs) and corresponding KERDI-BOARD-ZT washers. Screws must reach a depth of at least 3/4" (20 mm) in wood studs and 3/8" (10 mm) in metal studs. Maximum allowable on-center fastener spacing is 12" (30 cm) for walls and 6" (15 cm) for ceilings.
KERDI waterproofing membrane or KERDI-BOARD waterproof building panel shall be installed up to the height of the showerhead at minimum.
Any protrusions through the KERDI membrane or KERDI-BOARD panel
(e.g., showerhead, mixing valve, etc.) must be treated with
KERDI-SEAL-PS/-MV seals, KERDI-FIX or suitable sealant.
Solid Backing Materials
Gypsum wallboard – ASTM C1396/C1396M
Cementitious backer unit – ANSI A118.9 or ASTM C1325
Fiber-cement underlayment – ASTM C1288
Fiber-reinforced water-resistant gypsum backerboard/underlayment –
ASTM C1278
Coated glass mat water-resistant gypsum backerboard – ASTM C1178
Portland cement mortar – ANSI A108.1B
Concrete
Masonry
Setting and Grouting Materials
Unmodified thin-set mortar – ANSI A118.1
Grout – ANSI A118.3, A118.6, or A118.7
Installation Specifications
Solid backing panels – follow manufacturer’s instructions
Portland cement mortar bed – ANSI A108.1B
Tile – ANSI A108.5
Grout – ANSI A108.6, A108.10
Other Considerations
When KERDI or KERDI-BOARD and tile are installed on the ceiling, the solid backing and fasteners must be able to support the load of the tile and setting and grouting materials.
Shower grab bars must be anchored in the structure or solid blocking behind KERDI-BOARD.
Schluter ® -Systems profiles may be used to finish and protect outside corners and eliminate the use of sealant at inside corners; see page 36.
BATHTUB SURROUND 19
INSTALLATION
Walls and Ceilings
Please refer to Schluter ® -Systems' installation videos in addition to reading the instructions below.
Shower walls may be made waterproof using KERDI/KERDI-DS or KERDI-BOARD prior to construction of the shower base.
The waterproofing is carried to the height of the showerhead (at minimum). KERDI or KERDI-BOARD application on ceiling is optional for showers.
For continuous-use steam rooms, KERDI-DS is applied to walls and ceilings. For intermittent use steam showers, KERDI or KERDI-BOARD is applied to walls and ceilings.
Schluter
®
-KERDI or Schluter
®
-KERDI-DS over solid backing
The thin-set mortar used for bonding KERDI/-KERDI-DS to walls and ceilings must be appropriate for the substrate and must penetrate and engage the membrane fleece. For most substrates (e.g., gypsum board or CBU), an unmodified thin-set mortar is used. The mortar must be mixed to a fairly fluid consistency, but still able to hold a notch.
KERDI-FIX
1 Clean any dust or other debris from the surface of the solid backing. Dampen particularly dry and porous substrates in order to help prevent premature drying or skinning of the thin-set mortar.
2 Apply unmodified thin-set mortar using a 1/4" x 3/16" (6 mm x 5 mm) V-notched trowel or the KERDI-TROWEL. Embed
KERDI or KERDI-DS in the mortar and work the membrane onto the entire surface to ensure full coverage and remove air pockets.
3
KERDI-SEAL-PS/-MV
Seams in the membrane are constructed by overlapping the edges by 2" (50 mm) or by abutting adjacent sheets and installing
KERDI-BAND, centered over the joint.
Any protrusions through the membrane
(e.g., mixing valve, shower head, etc.) must be sealed with KERDI-SEAL-PS/-MV,
KERDI-FIX, or other suitable sealant.
Schluter
®
-KERDI-BOARD over wood or metal framing
Grab bars, wall-mounted toilets, or other heavy objects must be anchored in the structure or solid blocking behind KERDI-BOARD. Installation instructions for other applications of KERDI-BOARD (e.g. fully embedded or spot-bonded over solid backing) can be found in the 12.1 Schluter ® -KERDI-BOARD technical data sheet.
KERDI-FIX
1 KERDI-BOARD can be mounted vertically or horizontally on framing with appropriate screws
(i.e., coarse thread wood screw for wood studs and self-tapping for metal studs) and corresponding KERDI-BOARD-ZT washers.
Minimum board thickness = 1/2" (12.5 mm) for studs spaced at 16" (40.6 cm) o.c.; 3/4"
(19 mm) for studs spaced at 24" (61.0 cm) o.c.
Screws must reach a depth of at least 3/4" (20 mm) in wood studs and at least 3/8" (10 mm) in metal studs.
2 Abut panels over the center of the studs.
Screws may be placed between adjacent panels such that the washers fasten both panel edges. The maximum allowable on-center fastener spacing is 12" (30 cm) for walls and 6" (15 cm) for ceilings.
3
KERDI-SEAL-PS/-MV
KERDI-BOARD joints, corners, and fastener penetrations are sealed with KERDI-BAND and
KERDI-KERECK corners, ensuring a minimum
2" (50 mm) overlap. Apply unmodified thin-set mortar using a 1/4" x 3/16"
(6 mm x 5 mm) V-notched trowel or the
KERDI-TROWEL. Embed KERDI-BAND/-
KERECK in the mortar and work the membrane onto the surface to ensure full coverage and remove air pockets. Any protrusions through the panel (e.g., mixing valve, shower head, etc.) must be sealed with
KERDI-SEAL-PS/-MV, KERDI-FIX, or other suitable sealant.
20 INSTALLATION — Walls and Ceilings
INSTALLATION
Schluter
®
-KERDI-BOARD-SN Shower Niche
Please refer to Schluter ® -Systems' installation videos in addition to reading the instructions below.
The exact order of installation can vary from that shown below, provided all fastening and waterproofing measures are performed properly. The following represents Schluter ® -Systems' recommendations for simple and reliable installation.
Schluter
®
-KERDI over solid backing
1 Determine desired location and trace around the outside of the KERDI-BOARD-SN flange, making sure the lines are level and plumb.
Cut and remove the wallboard such that the niche will be supported on both sides by the studs or other wall framing.
2 Insert the niche and fasten to the studs using wood or metal screws, placing the fasteners approximately 1/4" (6 mm) from the edges of the niche. Fasten all corners and limit fastener spacing to 12" (30 cm) o.c.
3 Apply the KERDI membrane over the wall surface as described on page 20. Once the membrane is solidly embedded, cut the membrane to match the niche opening.
Schluter
®
-KERDI-BOARD over wood or metal framing
1 Determine desired location and trace around the outside of the KERDI-BOARD-SN flange, making sure the lines are level and plumb.
Cut and remove the KERDI-BOARD such that the niche will be supported on both sides by the studs or other wall framing.
2 Insert the niche and fasten to the studs using wood or metal screws and KERDI-BOARD-ZT washers, placing the fasteners along the seam between the KERDI-BOARD and the niche.
Fasten all corners and limit fastener spacing to
12" (30 cm) o.c.
3 Seal the seams between the niche and walls using KERDI-BAND with unmodified thin-set mortar ensuring a 2" (50 mm) overlap in all directions.
Note: When using the prefabricated shelf, determine the desired height of the shelf and mark with a level line. Set tile up to that line on the back and sides of the niche. Butter the sides and back of the shelf with unmodified thin-set mortar and solidly embed it in the niche, resting on the previously installed tile.
The shelf may be raised at the back to create a slope, or the tile may be set on a slope, to prevent water from pooling in the finished application.
INSTALLATION — Schluter
®
-KERDI-BOARD-SN Shower Niche 21
INSTALLATION
Shower Base with Schluter
®
-KERDI-DRAIN
Please refer to Schluter ® -Systems' installation videos in addition to reading the instructions below.
Preparation
Locate and cut a hole in the substrate for the drain outlet and coupling to the waste line using the template provided. Limit the diameter of the hole to
5" (125 mm) maximum to ensure proper support for the tile assembly.
Note: Fill in box-outs in concrete floors with dry-pack mortar or concrete. A pipe coupling or similar can be used as a form around the waste line.
Schluter
®
-KERDI-DRAIN with Schluter
®
-KERDI-SHOWER-ST prefabricated shower tray
The substrate must be clean, even, and load bearing. Any leveling must be done prior to shower tray installation. If necessary, cut the tray to size prior to application; ideally, the tray is cut equally on all sides to ensure a consistent perimeter height. The base can also be extended beyond the tray using dry-pack mortar.
Plumbing Access: If there is access to the plumbing from below and the waste line can be connected after installing KERDI-DRAIN, the tray can be installed prior to the drain.
1 Apply unmodified thin-set mortar to the substrate using a 1/4" x 3/8" (6 mm x 10 mm) square- or U-notched trowel.
2 Place the KERDI-SHOWER-ST tray and solidly embed in the mortar. Check the underside of the tray to ensure full coverage and support are achieved.
3 Completely fill the step in the shower tray with thin-set mortar. Press KERDI-DRAIN firmly into the mortar to ensure full support of the bonding flange.
No Plumbing Access: When there is no access to the plumbing from below, KERDI-DRAIN is installed to the appropriate height and connected to the waste line prior to the installation of the shower tray.
1 Begin by dry-fitting the components.
Measure and cut a section of pipe to connect
KERDI-DRAIN to the odor trap using the detachable center section of the tray or foam spacers included with the drain as a spacer. Prepare the odor trap, pipe, and
KERDI-DRAIN with cleaner, primer and ABS or PVC cement per the solvent cement manufacturer’s instructions and connect.
2 Apply unmodified thin-set mortar to the substrate and to the top and bottom of the detached center section of the KERDI-
SHOWER-ST tray. Slide the center section into place below the drain to ensure solid and uniform support of the bonding flange.
22 INSTALLATION — Shower base with Schluter
®
-KERDI-DRAIN
3 Apply unmodified thin-set mortar to the substrate using a 1/4" x 3/8" (6 mm x 10 mm) square- or U-notched trowel. Place the
KERDI-SHOWER-ST tray and solidly embed in the mortar. Check the underside of the tray to ensure full coverage and support are achieved.
Clamping Ring Drain Installed: If a clamping ring drain is installed, replace with KERDI-DRAIN or convert using the KERDI-DRAIN adaptor kit.
1 Remove the clamping ring from the installed drain and save the bolts. Align the bolt pattern of the clamping ring with the adaptor ring and punch the matching inserts through the adaptor ring.
2 Apply a 1/4" - 3/8" (6 mm - 10 mm) bead of KERDI-FIX to the installed drain flange.
Place the adaptor ring on the installed drain, re-insert the bolts, and tighten evenly. Make bolts finger-tight plus 1/4 turn; over tightening may warp the ring and result in leaks.
3 Slide the adaptor flange into the adaptor ring and ensure full support underneath with mortar or the detachable center section of the foam tray. Depending on the installed drain elevation, it may be necessary to install a polystyrene foam panel, tile backerboard, etc. prior to the tray. Install the tray as per the instructions on page 22.
Note: Schluter ® -Systems recommends a leak test be performed on the connection between the drain and the waste line prior to continuing with the remainder of the installation whenever possible.
Schluter
®
-KERDI-DRAIN with mortar bed
Plumbing Access: If there is access to the plumbing from below and the waste line can be connected after installing KERDI-DRAIN, the drain can be installed in conjunction with the mortar bed.
1 Place a ring of loose mortar up to the inlet hole in the floor and firmly press the drain into the mortar and level. The bonding flange must be fully supported to prevent damage to the tile assembly
(e.g., cracked grout around drain). When installing KERDI-DRAIN over wood substrates, the minimum thickness of mortar required at the perimeter of the bonding flange is 1" (25 mm).
2 The screed is then placed flush with the top of the bonding flange of the KERDI-DRAIN.
Slope the mortar bed at 1/4" (6 mm) per
12" (305 mm) using the bonding flange and a perimeter screed as guides.
No Plumbing Access: When there is no access to the plumbing from below, KERDI-DRAIN is installed to the appropriate height and connected to the waste line prior to the installation of the shower base.
1 Measure and cut a section of pipe to connect KERDI-DRAIN to the odor trap using the foam spacers included with the drain as a spacer. When installing KERDI-DRAIN over wood substrates, the minimum thickness of mortar required at the perimeter of the bonding flange is
1" (25 mm). Prepare the odor trap, cut section of pipe, and KERDI-DRAIN with cleaner, primer and ABS or PVC cement per the solvent cement manufacturer’s instructions and connect.
2 Pack loose mortar under the drain up to the inlet hole to ensure solid and uniform support of the bonding flange and level. The mortar bed is then placed according to the instructions above.
INSTALLATION — Shower base with Schluter
®
-KERDI-DRAIN 23
Clamping Ring Drain Installed: If a clamping ring drain is installed, replace with KERDI-DRAIN or convert using the KERDI-DRAIN adaptor kit.
1 Remove the clamping ring from the installed drain and save the bolts. Align the bolt pattern of the clamping ring with the adaptor ring and punch the matching inserts through the adaptor ring.
2 Apply a 1/4" - 3/8" (6 mm - 10 mm) bead of KERDI-FIX to the installed drain flange.
Place the adaptor ring on the installed drain, re-insert the bolts, and tighten evenly.
Make bolts finger-tight plus 1/4 turn; over tightening may warp the ring and result in leaks.
3 Slide the adaptor flange into the adaptor ring and ensure full support under the adaptor flange with mortar. The mortar bed is then placed according to the instructions on page 23.
Note: Schluter ® -Systems recommends a leak test be performed on the connection between the drain and the waste line prior to continuing with the remainder of the installation whenever possible.
Schluter
®
-KERDI-BOARD-SC curb and Schluter
®
-KERDI-SHOWER-SC/-SR curb or ramp
If necessary, cut the KERDI-BOARD-SC to length using a utility knife and KERDI-SHOWER-SC/-SR using a handsaw.
1 Apply unmodified thin-set mortar to the floor and to the edge of the shower base and walls using a 1/4" x 3/8" (6 mm x 10 mm) square- or U-notched trowel.
2 Press the curb or ramp firmly into place.
Check the underside of the curb or ramp to ensure that full coverage and support is achieved.
Note: Schluter ® -KERDI-BOARD can be used to build custom curbs.
Waterproofing the shower base
The KERDI or KERDI-DS waterproofing membranes can be installed over the KERDI-SHOWER-ST tray immediately or over a mortar bed as soon as the mortar bed can be walked upon using unmodified thin-set mortar. A pre-cut section of KERDI matching the dimensions of the tray is included with the KERDI-
SHOWER-ST for convenience. The thin-set mortar must be mixed to a fairly fluid consistency, but still able to hold a notch.
1 Apply unmodified thin-set mortar to the bonding flange and surrounding shower base with a 1/4" x 3/16" (6 mm x 5 mm) V-notched trowel or the KERDI-TROWEL. Note: When using the stainless steel drain, the membrane is adhered to the bonding flange with KERDI-
FIX; clean the bonding flange prior to KERDI-
FIX application.
2 Embed KERDI or KERDI-DS in the bond coat and work the membrane onto the
KERDI-DRAIN bonding flange and shower base to ensure full coverage and remove air pockets.
The membrane is carried to the step in the bonding flange (template provided) and to the edges of the shower base.
24 INSTALLATION — Shower base with Schluter
®
-KERDI-DRAIN
3 When using KERDI-SHOWER-SC/-SR, repeat the process to install the membrane over the curb or ramp. Seams in the membrane are constructed by overlapping the edges by 2" (50 mm) or by abutting adjacent sheets and installing KERDI-BAND centered over the joint. Install KERDI-KERECK at all inside and outside corners. When using KERDI-BOARD-
SC, seal the curb to the base and walls using
KERDI-KERECK and KERDI-BAND.
Grate assembly
Grate:
1 Place the height adjustment collar inside the lateral adjustment ring and snap the grate into place. Note: For the 6" (150 mm) grates, the height adjustment collar is integrated with the grate. For the residential adaptor kit, there is no lateral adjustment ring.
2 Fill the step in the bonding flange with thin-set mortar and back-butter the underside of the grate to ensure full support. Place the assembly into the mortar and install the surrounding tiles, ensuring full coverage.
3 Position the grate to match the joint pattern of the tile covering and press flush with the tile surface. Remove all excess setting material immediately. Note: Protect the visible surface of the grate from contact with setting and grouting materials. In particular, anodized aluminum is sensitive to alkaline materials.
Tileable Covering Support:
1 Fill the step in the bonding flange with thin-set mortar. Place the tile spacer in the lateral adjustment ring and press the assembly into the mortar. Install tiles up to the tile spacer, ensuring full coverage. Embed the tiles on the integrated tabs on the lateral adjustment ring, which provide for a flush transition to the covering support. Position the tile spacer to match the joint pattern of the tile covering.
The tiles may be held back from the spacer as required to match the layout. Remove all excess setting material.
2 Apply tile to the top of the covering support using unmodified thin-set mortar. The tile may overhang the covering support provided that a drainage opening of at least 3/16"
(5 mm) is provided.
3 After the tile is set and grouted, remove the tile spacer and insert the tiled covering support into the lateral adjustment ring.
INSTALLATION — Shower base with Schluter
®
-KERDI-DRAIN 25
INSTALLATION
Shower base with Schluter
®
-KERDI-LINE
Please refer to Schluter ® -Systems installation videos in addition to reading the instructions below.
Preparation
Locate and cut a hole in the substrate for the drain outlet and coupling to the waste line using the template provided. Limit the diameter of the hole to 5" (125 mm) maximum to ensure proper support for the tile assembly.
Note: Fill in box-outs in concrete floors with dry-pack mortar or concrete. A pipe coupling or similar can be used as a form around the waste line.
Schluter
®
-KERDI-LINE channel body installation
Plumbing Access: When there is access to the plumbing from below and the waste line can be connected after installing KERDI-LINE, the channel body may be set without making a connection to the waste line simultaneously.
1 Apply unmodified thin-set mortar to the substrate where the drain is to be placed with a notched trowel and solidly embed the channel support in the mortar.
2 Apply unmodified thin-set mortar to the top of the channel support and press the channel body firmly into the mortar, ensuring full support of the bonding flange. Check to make sure the KERDI-LINE is level.
No Plumbing Access: When there is no access to the plumbing from below, the channel body must be set and connected to the waste line simultaneously.
1
Begin the drain installation by dry fitting the components. Measure and cut a section of pipe to connect the coupling to the odor trap below the floor, using the channel support as a spacer.
2
Apply unmodified thin-set mortar to the top of the channel support with a notched trowel and press the channel support firmly onto the underside of the channel body.
Attach the mechanical coupling to the drain outlet and the cut section of the pipe per the coupling manufacturer’s instructions.
3
Apply unmodified thin-set mortar to the substrate where the drain is to be placed with a notched trowel. Prepare the cut section of pipe and odor trap with cleaner, primer and ABS or PVC cement per the solvent cement manufacturer’s instructions.
4 Solidly embed the channel support and KERDI-LINE into the mortar on the floor and connect the cut section of pipe to the odor trap. Check to make sure the KERDI-LINE is level.
Note: KERDI-FIX or other adhesives that are compatible with EPS foam can be used to install the channel support and channel body as an alternative to thin-set mortar. Apply a generous bead of
KERDI-FIX to the top and bottom of the channel support. The use of KERDI-FIX limits the ability to level KERDI-LINE.
Note: Schluter ® -Systems recommends a leak test be performed on the connection between the drain and the waste line prior to continuing with the remainder of the installation whenever possible.
Clamping Ring Drain Installed: If a clamping ring drain is already installed, the drain must be replaced with KERDI-LINE.
26 INSTALLATION — Shower base with Schluter
®
-KERDI-LINE
Schluter
®
-KERDI-LINE with Schluter
®
-SHOWER-L/-LS prefabricated tray
1 Any leveling of the floor must be done prior to the installation of the shower tray.
If necessary, cut the tray to size prior to application. The shower base can also be extended beyond the tray using dry-pack mortar, which is in turn covered with the
KERDI membrane.
2 Cut the flat end of the KERDI-SHOWER-L/-LS tray to fit around the channel support. Apply unmodified thin-set mortar to the substrate using a 1/4" x 3/8" (6 mm x 10 mm) square- or
U-notched trowel. Slide the KERDI-SHOWER-L/-LS under the edge of the channel body flush with the surface of the channel support, making certain to solidly embed the tray in the mortar. Check the underside of the tray to ensure that full coverage is achieved.
Note: When KERDI-LINE is placed at an intermediate location (e.g., center of shower), it is recommended that the KERDI SHOWER-L tray be cut by equal amounts from the ends to ensure a consistent height of the first course of tile. When KERDI-LINE is placed adjacent to a wall, cut the KERDI-SHOWER-LS tray from the thicker end to ensure a flush transition at the drain.
Schluter
®
-KERDI-LINE with m ortar base
1 Place a mortar screed opposite the installed
KERDI-LINE channel body.
2 Fill the remainder of the shower base with mortar and slope the mortar bed at 1/4"
(6 mm) per 12" (305 mm) using the bonding flange and a perimeter screed as guides.
3 As soon as the mortar bed can be walked upon, waterproofing with the
KERDI membrane can begin.
Schluter
®
-KERDI-BOARD-SC curb and Schluter
®
-KERDI-SHOWER-SC/-SR curb or ramp
If necessary, cut the KERDI-BOARD-SC to length using a utility knife and KERDI-SHOWER-SC/-SR using a handsaw.
1 Apply unmodified thin-set mortar to the floor and to the edge of the shower base and walls using a 1/4" x 3/8" (6 mm x 10 mm) square- or U-notched trowel.
2
Press the curb or ramp firmly into place.
Check the underside of the curb or ramp to ensure that full coverage and support is achieved.
Note: KERDI-BOARD can be used to build custom curbs.
INSTALLATION — Shower base with Schluter
®
-KERDI-LINE 27
Waterproofing the shower base
The KERDI-SHOWER-L/-LS trays are provided with integral waterproofing. When using a mortar bed, the shower base must be made waterproof using the
KERDI or KERDI-DS waterproofing membrane. The membranes can be installed as soon as the mortar bed can be walked upon.
1
Apply unmodified thin-set mortar to the shower base with a 1/4" x 3/16"
(6 mm x 5 mm) V-notched trowel or the
KERDI-TROWEL. The thin-set mortar must be mixed to a fairly fluid consistency, but still able to hold a notch.
2
Embed KERDI or KERDI-DS in the bond coat and work the membrane onto the entire surface to ensure full coverage and remove air pockets. The membrane is carried to the stainless steel bonding flange and to the edges of the shower base.
3 The KERDI collar on KERDI-LINE is integrated with the adjoining waterproofing assembly using unmodified thin-set mortar. The KERDI collar must be cut and folded where the
KERDI-LINE is installed adjacent to walls.
4
Seams in the membrane are constructed by overlapping the edges by 2" (50 mm) with unmodified thin-set mortar or by abutting adjacent sheets and installing KERDI-BAND with unmodified thin-set mortar, centered over the joint.
5 When using KERDI-SHOWER-SC/-SR, repeat the process to install the membrane over the curb or ramp. Seams in the membrane are constructed by overlapping the edges by 2"
(50 mm) or by abutting adjacent sheets and installing KERDI-BAND centered over the joint. Install KERDI-KERECK at all inside and outside corners. When using KERDI-BOARD-
SC, seal the curb to the base and walls using
KERDI-KERECK and KERDI-BAND.
28 SHOWER ASSEMBLY — Shower base with Schluter
®
-KERDI-LINE
Grate assembly
Grates A and B
1
Apply unmodified thin-set mortar to the underside of the grate frame and place it in the channel body ensuring full coverage and support of the frame. Insert the foam spacers in the grate frame to reinforce it during the remainder of the installation.
2
Slide the plastic height adjustment spacers with threaded bolts onto the tabs along the inside of the grate frame to adjust the elevation of the frame such that the surface of the frame will be flush with the surface of the tile covering. The spacers may be adjusted simply by turning the bolts by hand.
3 Install the tiles on the shower base using unmodified thin-set mortar, ensuring full coverage. Make final adjustments to ensure the grate frame is flush with surrounding tiles. Remove foam tile spacers and plastic height adjustment spacers with threaded bolts following tile installation.
Note: Protect the visible surfaces of the grate frame and grate from contact with setting and grouting materials. Setting and grouting materials must be removed immediately.
Covering support D
1 Peel the protective foil off the cover strip and adhere the strip to the bonding flange adjacent to the wall(s). Position the strip along the edge of the channel. The cover strip hides and protects the KERDI surface under the tile installed in step 3.
When the shower base will be tiled beyond the ends of the channel, the cover strip is not required at these locations.
2 Insert the tile spacers into the channel body.
Install the surrounding tile on the adjoining walls and shower base up to the spacers using unmodified thin-set mortar, ensuring full coverage. Remove all excess setting material.
3 Tile is bonded to the covering support using unmodified thin-set mortar. The tile is installed flush with the front side of the covering support to provide the drainage opening and overhanging the back side of the covering support to cover the bonding flange along the wall. When the ends of the channel body are located adjacent to walls, the tile is installed overhanging the end of the support to cover the bonding flange along the walls. Measure and cut the tile such that an approximate
1/16" (1 mm) gap is left at the walls.
Note: When the shower base is tiled beyond the ends of the channel, the tile on the ends of the covering support can be cut to either match the grout joints of the surrounding floor covering or to provide a perimeter drainage opening.
SHOWER ASSEMBLY — Shower base with Schluter
®
-KERDI-LINE 29
Optional Schluter
®
-SHOWERPROFILE-S/-R system profiles
Select SHOWERPROFILE-S according to shower base tile thickness and the height and length of the wall area to be covered. Select SHOWERPROFILE-R according to the height of the wall area to be covered.
SHOWERPROFILE-S
1
Measure the height of the area to be covered at the lowest point. Next, measure the length of the area and mark the profile where it is to be cut at both ends. Remove the protective foil and cut the tapered profile and support section to length
2
Place the tapered profile into the support section and apply unmodified thin-set mortar to the fleece on the back side of the profile.
3
Press the profile into place and align it flush with the wall tile. Immediately clean away any excess setting material. Install adjacent tiles on the shower base.
SHOWERPROFILE-R
1 Measure the length of the area to be covered. Remove the protective foil and cut the profile to length.
2 Connect the two components of
SHOWERPROFILE-R to achieve the desired height. Small pieces of tape can be used to help maintain the position of the components during installation.
3 Apply unmodified thin-set mortar to the fleece on the back side of the profile. Press the profile into place and align it flush with the wall tile. Immediately clean away any excess setting material.
Note: The Schluter ® -PROCUT-TSM cutting wheel can be used with an angle grinder set to low speed to cut the stainless steel profiles. The
SHOWERPROFILE-S support section can be cut with snips. Please read and follow all safety instructions from the grinder manufacturer to prevent injury.
Schluter
®
-KERDI-LINE-FC
KERDI-LINE-FC may be used with tiles that are 1/4" (6 mm) thick or greater, to connect adjacent KERDI-LINE grates A and B.
35 mm - 1-3/8''
1
Install KERDI-LINE channel bodies end-to-end and overlap the KERDI collars using unmodified thin-set mortar to ensure a waterproof connection.
2
Apply a sufficient amount of thin-set mortar to the substrate and/or the back of
KERDI-LINE-FC and press the profile into the mortar until its surface is flush with the adjacent tile and grate assembly. Leave a space of approximately 1/16" – 1/8"
(1.5 – 3 mm). Fill the joints completely with grout or setting material.
30 SHOWER ASSEMBLY — Shower base with Schluter
®
-KERDI-LINE
Schluter
®
-SHOWERPROFILE-WS
SHOWERPROFILE-WS can be used in conjunction with tiles that are 5/16" (8 mm) thick or greater.
1
2
Install the tile covering up to where the profile will be installed.
Apply a sufficient amount of thin-set mortar to this area and to the back of the profile to achieve full coverage. Press the profile into the mortar until its surface is flush with the tile.
3
4
Set adjacent rows of tile, leaving a space of approximately 1/16" - 1/8" (1.5 - 3 mm) between the profile and tile.
Cut the SHOWERPROFILE-WSL/-WSC insert to length and insert into the profile.
Schluter
®
-SHOWERPROFILE-WSK
SHOWERPROFILE-WSK is applied to the floor covering using Schluter ® -KERDI-FIX, silicone, or similar adhesive. Prior to applying the adhesive, make sure the surfaces are free from any adhesion-inhibiting substances such as oil or grease.
3 Cut the SHOWERPROFILE-WSL/-WSC insert to length and insert into the profile.
1 Apply a bead of adhesive to the underside of the profile legs where contact is made with the floor, and set the profile. Note: End caps are used when the profile does not abut a vertical surface. Install end caps with
Schluter ® -KERDI-FIX, silicone, or a similar adhesive before installing the profile.
2 Use a suitable cleaning agent to remove any excess adhesive after placement of the profile.
SHOWER ASSEMBLY — Shower base with Schluter
®
-SHOWER Profiles 31
INSTALLATION
Bathtub surround
Please refer to Schluter ® -Systems' installation videos in addition to reading the instructions below.
The waterproofing is carried to the height of the showerhead (at minimum). KERDI or KERDI-BOARD application on ceiling is optional for bathtub surrounds.
Schluter
®
-KERDI over solid backing
The thin-set mortar used for bonding KERDI to walls and ceilings must be appropriate for the substrate and must penetrate and engage the membrane fleece. For most substrates (e.g., gypsum board or CBU), an unmodified thin-set mortar is used. The mortar must be mixed to a fairly fluid consistency, but still able to hold a notch.
1
Clean any dust or other debris from the surface of the solid backing. Dampen particularly dry and porous substrates in order to help prevent premature drying or skinning of the thin-set mortar.
2
Place painter’s tape to protect the tub deck.
Apply unmodified thin-set mortar to the solid backing using a 1/4" x 3/16" (6 mm x 5 mm) V-notched trowel or the KERDI-
TROWEL. Completely fill the 1/4" (6 mm)wide gap between the solid backing and tub with KERDI-FIX or other suitable sealant.
Note: When the solid backing is installed above the tub flange, apply KERDI-FIX to the tub flange and spread using a small notched trowel.
3
Apply KERDI-BAND waterproofing strips or
5" (125 mm)-wide cut sections of KERDI waterproofing membrane. Solidly embed the membrane in the mortar and KERDI-FIX to ensure full coverage and remove air pockets.
4
Apply unmodified thin-set mortar to the solid backing and previously applied
KERDI-BAND. Embed the KERDI in the thin-set mortar and work the membrane onto the entire surface to ensure full coverage and remove air pockets.
5
Seams in the membrane are constructed by overlapping the edges of KERDI by
2" (50 mm) or by abutting adjacent sheets of
KERDI and installing KERDI-BAND, centered over the joint.
KERDI-SEAL-PS/-MV KERDI-FIX
6
Any protrusions through the KERDI membrane
(e.g., mixing valve, shower head, etc.) must be sealed with KERDI-SEAL-PS/-MV, KERDI-FIX, or other suitable sealant.
7 Seal connections to knee walls using
KERDI-KERECK-F preformed corners and unmodified thin-set mortar.
Note: See page 21 for KERDI-BOARD-SN shower niche installation instructions.
8 Once the entire membrane, including seams, corners, and knee walls have been completely bonded and, therefore, waterproofed, the assembly is ready to be tiled.
32 INSTALLATION — Bathtub surround — Schluter
®
-KERDI
Schluter
®
-KERDI-BOARD over wood or metal framing
Grab bars or other heavy objects must be anchored in the structure or solid blocking behind KERDI-BOARD. Installation instructions for other applications of KERDI-BOARD (e.g. fully embedded or spot-bonded over solid backing) can be found in the 12.1 Schluter ® -KERDI-BOARD technical data sheet.
1
KERDI-BOARD can be mounted vertically or horizontally on framing with appropriate screws (e.g., coarse thread wood screw for wood studs and self-tapping for metal studs) and corresponding KERDI-BOARD-ZT washers. Minimum board thickness = 1/2"
(12.5 mm) for studs spaced at 16" (40.6 cm) o.c.; 3/4" (19 mm) for studs spaced at 24"
(61.0 cm) o.c. Screws must reach a depth of at least 3/4" (20 mm) in wood studs and at least 3/8" (10 mm) in metal studs.
2
Abut panels over the center of the studs or other solid backing. Screws may be placed between adjacent panels such that the washers fasten both panel edges. The maximum allowable on-center fastener spacing is 12" (30 cm) for walls and
6" (15 cm) for ceilings.
3
Place painter’s tape to protect the tub deck.
Apply unmodified thin-set mortar to the KERDI-BOARD using a 1/4" x 3/16"
(6 mm x 5 mm) V-notched trowel or the KERDI-TROWEL. Completely fill the
1/4" (6 mm)-wide gap between the
KERDI-BOARD and tub with KERDI-FIX or other suitable sealant.
Note: When KERDI-BOARD is installed above the tub flange, apply KERDI-FIX to the tub flange and spread using a small notched trowel.
4
Apply KERDI-BAND waterproofing strips.
Solidly embed the membrane in the mortar and KERDI-FIX to ensure full coverage and remove air pockets.
5 KERDI-BOARD joints, corners, and fastener penetrations are sealed with KERDI-BAND, ensuring a minimum 2" (50 mm) overlap.
KERDI-SEAL-PS/-MV
6 Any protrusions through the panel
(e.g., mixing valve, shower head, etc.) must be sealed with KERDI-SEAL-PS/-MV,
KERDI-FIX, or other suitable sealant.
7 Seal connections to knee walls using
KERDI-KERECK-F preformed corners and unmodified thin-set mortar.
Note: See page 21 for KERDI-BOARD-SN shower niche installation instructions.
8 Once all seams, corners, and knee walls have been completely sealed, the assembly is waterproofed and ready to be tiled.
INSTALLATION — Bathtub surround — Schluter
®
-KERDI-BOARD 33
BARRIER-FREE SHOWERS
Accessibility and style
As our population ages, there is increasing demand for accessible living spaces. Tiled showers typically feature curbs to retain water in the stall, which can make entry difficult for those with limited mobility, including individuals who need the assistance of wheelchairs.
Barrier-free tiled showers eliminate the use of a curb and rely on the slope of the floor to keep water inside the stall, thus improving accessibility. These showers have also become increasingly popular for their aesthetic benefits, as they can integrate seamlessly with surrounding tiled surfaces to enhance an already luxurious environment.
DESIGN AND INSTALLATION CONSIDERATIONS
The Schluter ® -Shower System provides a simple and effective means of waterproofing barrier-free installations. The key to this is that the
KERDI waterproofing membrane is topically applied. Once the slope to the drain is established, KERDI and tile are installed, thus minimizing the thickness of the assembly.
Barrier-free tiled showers rely on the slope of the floor to effectively contain water in the immediate shower area and direct water to the drain. Given the wide range of potential configurations, it isn’t possible to address them all in this Handbook. However, the following guidelines will assist in planning any barrier-free installation.
Ideally, the floor will be recessed before installing a sloped mortar bed or the KERDI-SHOWER prefabricated shower trays to allow an even transition at the door threshold. This can be relatively straightforward in new construction and can also be accomplished in renovations.
When recessing the floor is not an option, it is necessary to provide a ramp up into the shower area. The KERDI-SHOWER prefabricated trays and ramp can be useful tools in such applications as well. Please note that recessing the floor of a bathroom must be done in a way that preserves the structural integrity and safety of the construction. This may require the services of a qualified design professional (e.g., architect, engineer, etc.).
Waterproofing must be installed in all areas subject to water exposure. Ideally, the entire floor is protected. Install KERDI over mortar beds and Schluter ® -Systems prefabricated EPS foam substrates. Use the DITRA or DITRA-HEAT uncoupling membrane over plywood/OSB or concrete subfloors. All seams are sealed using KERDI-BAND. The SHOWERPROFILE-WS/-WSK splash guard profiles may be used at the entrance of barrier-free showers. Secondary drainage may be required in the drying area for any overflow. Please see detail K-SHBF on page 10 for further discussion.
Note on Accessibility Guidelines:
Various building codes and other sources, such as the Americans with Disabilities Act, include specific requirements for disabled access in public buildings and should be consulted when applicable. Areas of interest may include degree of slope, clearance, and supporting structures such as grab bars.
34 BARRIER-FREE SHOWERS — Accessibility and style
THE WATERPROOF BATHROOM
Security and utility
Bathrooms are a primary focus of today’s building and remodeling projects and are becoming more and more luxurious, complete with steam showers, oversized bathtubs, and the latest in fixtures and lighting. As such, tiled showers, bathtub surrounds, floors, walls, and vanities are in high demand. Tile and stone are beautiful, durable, and available in a wide range of formats, colors, and textures, allowing limitless design options. Tile and stone offer unmatched utility and high-end appeal, making them the ideal surface coverings for bathrooms. Given the substantial investments made in these projects and nature of use, long-term durability is a high priority.
DITRA
KERDI
Waterproofing is the foundation of successful tiled bathrooms. Moisturesensitive construction materials (e.g., wood framing, plywood and OSB sheathing, gypsum wallboard, etc.) are common in the North American building environment and must be protected in wet areas. Wet areas also bring the potential for mold growth if effective moisture management is not provided. The key to mold control is moisture control.
In addition to showers and tub surrounds, bathroom floors surrounding these fixtures are routinely subjected to water exposure during use.
Bathroom floors may also, through unexpected circumstances, become exposed to significant amounts of water; for example, an overflowed toilet or ruptured sink supply, which can result in flooding. Waterproofing these floors can save an owner from replacing the tile assembly and substructure in the event of a leak.
Schluter ® -Systems offers simple and effective solutions to protect moisture-sensitive substrates, prevent mold growth, and preserve the integrity of the tiled surface throughout the bathroom.
The Schluter ® -Shower System is an integrated family of products that together form a fully bonded, watertight assembly for tiled showers and bathtub surrounds. DITRA is an uncoupling membrane that protects the tiled floors from damage by neutralizing differential movement stresses between the substrate and tile and provides reliable waterproofing. Since both of these systems are based on topically-applied, bonded waterproof membranes, they can be combined simply and easily to provide waterproofing throughout the bathroom.
Floors can be made fully waterproof with DITRA. Since the membrane is made of waterproof polyethylene, the only extra step necessary is to seal the seams and floor/wall connections with KERDI-BAND. The same practice is used to integrate the DITRA with the KERDI used to waterproof the shower or tub surround. The result is a comprehensive waterproofing system that protects against moisture penetration.
For added luxury, the DITRA-HEAT electric floor warming system with integrated uncoupling technology ensures that floors are both comfortable, and resistant to cracked tiles and grout. Cables can be placed wherever heat is desired for customized heating zones, and no leveling compounds are required, making for a quick and easy installation.
Please consult the Schluter ® -DITRA and Schluter ® -DITRA-HEAT
Installation Handbooks for comprehensive installation guidelines and warranty criteria.
Schluter ® -DITRA and Schluter ® -DITRA-HEAT
Installation Handbooks
Complete details and illustrations for tile installations over various substrates, and supplementary information on topics such as waterproofing, movement joints, and thin-set mortars.
To obtain or download a free copy of the DITRA or DITRA-HEAT Installation Handbook, visit www.
schluter.com or call 1-800-472-4588 (US) or 1-800-
667-8746 (CAN).
THE WATERPROOF BATHROOM — Security and utility 35
PROFILES
Details make the difference
Ceramic and stone tiles are durable, easy to maintain, and hygienic, representing the ideal surface coverings for showers and bathtub surrounds. Exposed tile edges, however, are unsightly and prone to cracking and chipping. While ceramic trim pieces such as bullnose or quarter round have traditionally been used to finish and protect tile edges at the outside corners and perimeters of an installation, ceramic trim availability can be limited, particularly in imported tile lines, which can in turn limit overall tile selection.
Ceramic cove base represents a neat, hygienic method for treating transitions at inside corners by providing a curved surface that prevents the collection of dirt and is easy to clean. However, the limited availability of ceramic trim pieces has resulted in the use of sealant and caulk to treat such transitions.
These joints must be continually maintained throughout the life of the installation. This may include replacing the joints, which requires cutting the sealant out and possibly compromising the waterproofing membrane.
Finishing and edge protection Maintenance-free inside corners
Schluter ® -Systems offers various finishing and edge-protection profiles for outside corners and other tiled edges that can be used with any field tile, thus reducing dependence on ceramic trim and increasing design options.
These profiles are available in a wide range of materials and finishes such as stainless steel, anodized aluminum, brass, and colored PVC to produce a variety of looks, including bold contrasts, discreet color matches to the grout, and complements to plumbing fixtures.
Schluter ® -Systems offers various cove-shaped profiles to address the need to finish inside corners. These profiles can be used with any field tile to produce permanent, easy to clean, and maintenance-free floor/wall transitions and inside wall corners.
Schluter ® -DILEX-AHK
Allows for easy cleaning and will not trap debris. Anodized and Tuscan color-coated aluminum finishes.
Schluter ® -RONDEC
Provides a symmetrically rounded edge for a smooth design.
Schluter ® -QUADEC
Provides a square edge for a contemporary and sleek design.
Schluter ® -DILEX-HKU
Allows for easy cleaning, will not trap debris.
Stainless steel finish.
TILE
TILE TILE
TILE
TILE
Schluter ® -DILEX-PHK
Allows for easy cleaning and will not trap debris. PVC profile.
Schluter ® -DILEX-EKE
Provides a straight and discreet joint that eliminates sealant at inside corners.
TILE TILE
Please refer to our Illustrated Price List or our website at www.schluter.com for details on the complete line of Schluter profiles and accessories available.
36 PROFILES — Details make the difference
THIN-SET FACTS
Discussion on thin-set mortars and Schluter
®
-KERDI installations
QUESTION: Should a latex-modified thin-set mortar or an unmodified thin-set mortar be used to install Schluter
®
-KERDI?
ANSWER:
The type of bonding mortar used to apply KERDI must be suitable for the substrate and mechanically anchor the fleece on the KERDI. For all the substrates listed in this Handbook (e.g., gypsum board, cement backerboard, etc.), an unmodified thin-set mortar is recommended. When installing KERDI with unmodified thin-set mortar over particularly dry and porous substrates, it is recommended to wet the substrate first, in order to help prevent premature drying or skinning of the thin-set mortar.
Unmodified thin-set mortar must be used to construct all KERDI seams to ensure watertight performance of the system. Learn more below.
QUESTION: Can ceramic tile, including porcelain tile, be set on Schluter
®
-KERDI with unmodified thin-set mortar?
ANSWER: YES. In fact, we recommend it. Here’s why:
Portland cement-based unmodified thin-set mortars are dependent on the presence of moisture for hydration in order to gain strength.
Since KERDI is impervious, it does not deprive the mortar of its moisture. This allows the cement to properly hydrate, resulting in a strong, dense bond coat. In fact, after the mortar has reached final set (usually within 24 hours), unmodified thin-set mortars achieve higher strengths when cured in continually moist conditions.
QUESTION: Can ceramic tile, including porcelain tile, be set on Schluter
®
-KERDI with latexmodified thin-set mortar?
ANSWER: We DON’T recommend it. Here’s why:
Latex-modified mortars must air dry for the polymers to coalesce and form a hard film in order to gain strength. When sandwiched between two impervious materials such as KERDI and ceramic tile, including porcelain tile, drying takes place very slowly through the open joints in the tile covering. [According to the Tile Council of North America's Handbook for Ceramic, Glass, and Stone Tile Installation, this drying period can fluctuate from 14 days to over 60 days, depending on the geographic location, the climatic conditions, and whether the installation is interior or exterior]. Therefore, extended cure times would be required before grouting if using modified thin-set mortars between KERDI and ceramic tile, including porcelain tile. If extended cure times were not observed, the results could be unpredictable.
This is even more important to consider in wet areas such as showers, as there is the additional concern of latex leaching.
QUESTION: How do I know if the thin-set mortar is modified or unmodified?
ANSWER:
In general, unmodified thin-set mortar is a blend of Portland cement, sand, and water retention agents that is mixed with water by the user.
The applicable product standard for unmodified thin-set mortars is ANSI A118.1. Look for this standard on the packaging (e.g., product meets ANSI A118.1 when mixed with water). Unmodified thin-set mortar may also be referred to as dry-set mortar by the manufacturer.
Modified thin-set mortars are similar to unmodified thin-set mortars, but include additional polymers such as latex. The additional polymers are introduced in either liquid or powder form. In the first case, the user mixes an unmodified or dry-set mortar powder with a liquid polymer additive instead of water. In the second case, the polymers are added by the manufacturer to the dry blend in powder form. The user then mixes the powder with water. The applicable product standards for modified thin-set mortars include ANSI A118.4 and ANSI A118.11.
ADDITIONAL NOTES
• Over 25 years of field experience and testing by the Tile Council of North America (TCNA) support the efficacy of using unmodified thinset mortars in conjunction with KERDI in tiled showers.
• Remember, all thin-set mortars have an acceptable temperature range that must be observed during application and curing.
• Pre-mixed thin-set mortars and mastics are not suitable for use in conjunction with the Schluter ® -Shower System.
THIN-SET FACTS — Discussion on thin-set mortars and Schluter
®
-KERDI installations 37
TESTING, LISTINGS, & APPROVALS
Products and system evaluation
Schluter ® -Systems is committed to providing reliable installation systems for tile and stone. As part of this commitment, we have invested considerable resources in testing our products and obtaining listings and approvals through various certification organizations to provide our customers and local code officials with relevant data that supports the efficacy of our system.
TEST DATA
KERDI, KERDI-DS, DITRA, DITRA-XL, DITRA-HEAT, and DITRA-HEAT-TB have been independently tested and found to meet or exceed the requirements of the American National Standard Specifications for Load Bearing, Bonded, Waterproof Membranes for Thin-set
Ceramic Tile and Dimension Stone Installation A118.10. Data for KERDI and KERDI-DS are presented in the table below.
Property
Fungus and micro-organism resistance
Seam strength
Breaking strength
Dimensional stability
Waterproofness
7-day shear strength
7-day water immersion shear strength
4-week shear strength
12-week shear strength
100-day water immersion shear strength
Requirement
The membrane shall not support mold growth
16 lb/2 in width
170 psi
0.7% maximum length change
No moisture penetration
50 psi
50 psi
50 psi
50 psi
50 psi
KERDI
Pass
36 lb/2 in width
Performance
KERDI-DS
Pass
37 lb/2 in width
1084 psi
Pass
Pass
87 psi
77 psi
96 psi
90 psi
120 psi
1275 psi
Pass
Pass
87 psi
99 psi
93 psi
87 psi
116 psi
KERDI, KERDI-DS, and KERDI-BOARD have also been independently tested to determine the water vapor permeance of the products.
Please see further discussion on the importance of water vapor permeance on page 40.
Product
KERDI
KERDI-DS
KERDI-BOARD 1/2" (12.5 mm)
* Using the desiccant method at 100°F (38°C) and 90% RH
Test method
ASTM E96*
Performance
0.90 perms
0.19 perms
0.36 perms
PRODUCT EVALUATIONS AND LISTINGS
Schluter ® -Shower System (Membranes and Drains)
• ICC-ES PMG Report No. PMG-1204
Membranes (KERDI/DITRA/DITRA-XL/DITRA-HEAT
1 /DITRA-HEAT-TB 1 )
• ICC-ES Report No. ESR-2467 • Listed by cUPC® to meet ANSI A118.10 • Los Angeles Research Report
1 DITRA-HEAT and DITRA-HEAT-TB membranes are not included in the Los Angeles Research Report.
Drains (KERDI-DRAIN and KERDI-LINE)*
• Listed by UPC
®
to meet IAPMO IGC 195
• Certified by CSA to meet CSA B79
• Certified by NSF as special engineered product to meet applicable requirements of ASME A112.6.3
• Los Angeles Research Report
*KERDI-DRAIN and KERDI-LINE are available in various configurations. Please refer to pages 41 to 43 for information regarding which configurations are listed and certified.
APPROVALS
Schluter ® -Shower System
• Massachusetts • Michigan • Kentucky
Copies of the aforementioned test reports, listings, and approvals are available upon request. Listings and approvals may also be accessed via our website at www.schluter.com.
38 TESTING, LISTINGS, & APPROVALS — Products and system evaluation
MOLD
The importance of mold control
The term “mold” is used to describe visible fungal growth. Mildew is another common term which refers to the type of fungi found growing on window sills and in bathrooms. Fungi are everywhere in our environment and are found both indoors and outdoors. However, the type and amount found in the home can be an important health issue. Understanding how to effectively control mold growth is very important.
What is Mold?
Fungi are different from plants and animals. Fungi cannot produce their own nutrients as plants do and reproduce differently than both plants and animals. Molds reproduce by making spores which travel through the air to deposit on surfaces. If the conditions are right for reproduction they can grow and continue to multiply. The filamentous parts of mold attach to nutrients and form networks called mycelia. It is these networks that are visible to us in the indoor environment. Molds come in a variety of colors, but we commonly see them as green or black.
Over 1000 different species of mold have been identified in homes, but they are not all toxic to humans. Molds growing inside a home may release chemicals and spores and some may even produce mycotoxins. The chemicals released by fungi are called volatile organic compounds (VOC). For example, ethanol is a common VOC that is responsible for the distinctive musty or earthy odor associated with mold.
Health Effects
Mold can cause damage to building materials and may have adverse health effects on some individuals. The susceptibility of people to develop symptoms depends on the nature of the fungal material, genetic predisposition, age, state of health, and extent of exposure. Although there is insufficient evidence in the scientific community to determine with certainty the association between mold exposure and the effect on human health, it is of course recommended to control mold exposure in the home and workplace. Common health effects associated with exposure to mold are a variety of upper and lower respiratory tract symptoms: cough; nose, throat and eye irritation; rhinitis; sneezing; and wheezing.
These symptoms are similar to allergies and associated with asthma. Mycotoxins are fungal metabolites that have a toxic effect on humans.
Toxic effects are associated with symptoms such as fever, nausea, headaches, and skin irritations.
Factors for Mold Growth
Fungi need a source of moisture, organic material to serve as a source of nutrients, and a warm environment with a temperature range from
50 to 107 °F (10 to 42 °C) to grow. For most species of fungi, a neutral to acidic pH is preferred, with a high pH level indicating an alkaline environment that is generally not conducive to mold growth. Mold will reproduce in such conditions as long as moisture is present. Once the area is dry, the mold may stop reproducing but can continue to be allergenic to susceptible people. If moisture is reintroduced, the mold will again start the reproduction cycle and grow.
Controlling Mold Growth
As stated above, four conditions must be satisfied to support mold growth.
1. Mold spores
2. Food source (organic material)
3. Warm temperatures: 50 to 107 °F (10 to 42 °C)
4. Moisture
Mold spores travel through the air indoors and outdoors and are impossible to eliminate. The use of organic materials in construction is common in today’s building environment. Examples include wood framing members (e.g., studs, joists, I-joists, and trusses), plywood or OSB subfloors, paper-faced gypsum boards on walls and ceilings, etc. Room temperature falls within the temperature range suitable for mold growth.
Therefore, the control of moisture, including liquid water and water vapor, is the only viable method for controlling mold growth in the indoor environment.
Showers are critical areas with respect to mold and moisture control. They are commonly exposed to thousands of gallons of water per year and high humidity levels. The tile covering alone will not prevent water and moisture penetration. As such, it is essential that an effective moisture management system be designed and installed properly to protect surrounding building materials and prevent mold growth.
The traditional method for installing tiled shower assemblies creates a water in/ water out system. Since shower pan liners are placed below the mortar setting bed in these assemblies, moisture is allowed to saturate the mortar bed before exiting the system through the weep holes in the drain. When the pan liner is placed on a level substrate instead of a sloped surface, a relatively common error, moisture in the system will have no means to exit through the weep holes in the drain and the mortar bed will remain saturated for extended periods of time. The continued presence of moisture, combined with organic materials carried into the mortar bed by the rinse water, warm temperatures, and reduced pH as soluble salts are washed out of the mortar bed, increases the risk of mold growth within the system.
The Schluter ® -Shower System is an integrated family of products that creates a sealed system. KERDI is a bonded waterproof membrane that is installed on top of the mortar bed and solid backing on walls. Tile is installed directly over the membrane using thin-set mortar. The
KERDI-DRAIN was designed specifically to ensure a simple and secure connection to bonded waterproof membranes, such as KERDI, at the top of the assembly rather than below it. The resulting assembly does not permit moisture penetration into the solid backing or mortar bed, thus limiting the amount of water behind the tile covering and allowing the shower to dry out between uses. Furthermore, KERDI is a vapor retarder that protects wall cavities from water vapor penetration. Thus, the Schluter ® -Shower System provides superior moisture management and reduces the potential for mold growth within the system.
Regardless of the system used to waterproof a tiled shower, it is important to provide adequate ventilation (e.g., exhaust fans) in the bathroom to effectively manage water vapor and reduce condensation on all bathroom surfaces.
Further discussion and recommendations for mold remediation can be found in various sources, including the following.
• “A Brief Guide to Mold, Moisture, and Your Home” – U.S. Environmental Protection Agency (EPA)
• “Mold Remediation in Schools and Commercial Buildings” – U.S. Environmental Protection Agency (EPA)
• “Mould Guidelines for the Canadian Construction Industry” – Canadian Construction Association
MOLD — The importance of mold control 39
VAPOR
The importance of water vapor management
Why is water vapor management important?
It is important to consider that water exists as both liquid and vapor in showers, and must be managed in both forms. The prime example of this is the steam shower. Steam showers that are not designed to manage water vapor have caused mold growth in wall cavities, rot in wood framing, and damage to moisture-sensitive wall coverings on the opposite side of the stud cavities.
Do all waterproofing membranes manage water vapor?
The ANSI A118.10 standard for bonded waterproof membranes was developed to provide a framework for determining the suitability of these products to serve as barriers to liquid water only. As such, the standard does not include a minimum criterion to establish the ability of products to limit vapor transmission. Thus, simply selecting a membrane that meets the requirements of the ANSI A118.10 standard for a steam shower application is not enough. The ability of the product to limit vapor transmission must be considered as well.
How can I identify a waterproofing membrane that manages water vapor?
Water vapor permeance is a measure of how quickly water vapor is transmitted through a material and can be determined according to the
ASTM E96 Standard Test Method for Water Vapor Transmission of Materials. The higher the vapor permeance, the less effective a material is at slowing vapor transmission.
There is no universal requirement for vapor permeance of membranes in the building industry. The environmental conditions (i.e., differences in temperature and relative humidity), building materials, etc., and relevant field experience will determine the appropriate membrane performance for a given application. The consensus within the tile industry in North America has been that a vapor permeance of 1.0 perm or less will manage vapor effectively in showers and intermittent use steam shower applications.
The TCNA Handbook for Ceramic, Glass, and Stone Tile Installation and the TTMAC Specification Guide 09 30 00 Tile Installation Manual specify a water vapor permeance of 0.5 perms or less for bonded waterproofing membranes used in continuous use steam rooms
(e.g., those found in health clubs, spas, etc.) when tested using the desiccant method at 100°F (38°C) and 90% RH.
Does the Schluter
®
-Shower System manage water vapor?
Schluter ® -Systems has tested the various options within the Schluter ® -Shower System for moisture management, including KERDI,
KERDI-DS, and KERDI-BOARD in the more aggressive conditions referenced above. The table below summarizes Schluter ® -Systems' recommendations for the use of these products and respective water vapor permeance values.
Product
KERDI
KERDI-DS
KERDI-BOARD
Recommended Applications
Showers, intermittent use steam showers, and bathtub surrounds
Continuous use steam rooms
Showers, intermittent use steam showers, and bathtub surrounds
1 Tested according to ASTM E96, using the desiccant method at 100°F (38°C) and 90% RH
2 1/2" – 12.5 mm-thick KERDI-BOARD tested
Water Vapor Permeance (perms) 1
0.90
0.19
0.36
2
While the water vapor permeance of KERDI-BOARD meets the water vapor permeance recommendations for continuous use steam rooms in tile industry standard guidelines, Schluter ® -Systems has chosen to require the KERDI-DS membrane for these demanding applications in an effort to be conservative and provide the best possible solution for our customers.
Thus, the Schluter ® -Shower System has solutions that provide superior moisture management for virtually any tile application.
40 VAPOR — The importance of water vapor management
PRODUCT & ORDERING INFO
Ordering information for the Schluter
®
-Shower System and DITRA components outlined in this Handbook is located below.
For technical support, our Illustrated Price List, or additional information on our complete product line, please call 1-800-472-4588 (USA) or 1-800-667-8746 (Canada), or visit our comprehensive website at www.schluter.com.
Waterproofing strip
Inside corner (FI)
Left corner (L)
KERDI-SEAL-PS
Outside corner (FA)
Right corner (R)
KERDI-SEAL-MV
KERDI-FIX
* Color codes: BW - Bright white, G - Grey
Note: 1 mil = 1 one-thousandth of an inch.
KERDI is listed by cUPC
® and evaluated by ICC-ES
(Report Nos. ESR-2467 and PMG-1204).
Schluter ®
-KERDI
KERDI is a pliable sheet-applied polyethylene waterproofing membrane and vapor retarder that guarantees uniform thickness. It is covered on both sides with a fleece webbing to anchor the membrane in thin-set mortar.
KERDI waterproofing membrane
Item No.
Dimensions
KERDI 200/5M
KERDI 200/10M
KERDI 200/20M
KERDI 200
3' 3" x 16' 5" = 54 ft 2 (1 m x 5 m = 5 m 2 )
3' 3" x 33' = 108 ft 2 (1 m x 10 m = 10 m 2 )
3' 3" x 65' 7" = 215 ft 2 (1 m x 20 m = 20 m 2 )
3' 3" x 98' 5" = 323 ft 2 (1 m x 30 m = 30 m 2 )
KERDI-DS waterproofing membrane
KERDI-DS 3' 3" x 98' 5" = 323 ft 2 (1 m x 30 m = 30 m 2 )
KERDI-BAND waterproofing strip
KEBA 100/125/5M
KEBA 100/125/10M
KEBA 100/185/5M
KEBA 100/250/5M
KEBA 100/125
KEBA 100/185
KEBA 100/250
5" x 16' 5" (125 mm x 5 m)
5" x 33' (125 mm x 10 m)
7-1/4" x 16' 5" (185 mm x 5 m)
10" x 16' 5" (250 mm x 5 m)
5" x 98' 5" (125 mm x 30 m)
7-1/4" x 98' 5" (185 mm x 30 m)
10" x 98' 5" (250 mm x 30 m)
KERDI-KERECK-F waterproofing corners
Item No.
KERECK/FI 2
KERECK/FI 10
Type/Quantity
Inside corner / 2 units
KERECK/FA 2
KERECK/FA 10
Inside corner / 10 units
Outside corner / 2 units
Outside corners / 10 units
KERDI-KERECK-F 135º inside and bench corners
Item No.
KERSB135K
KERECK135FI2
Packaging
Bench/neo-angle package
1 left and 1 right bench corner, 2 135º inside corners
135º inside corners / 2 units
KERECK135FI10
KERSB135KLR
135º inside corners / 10 units
1 left and 1 right bench corner
KERSB135K5LR 5 left and 5 right bench corner
KERDI-KERS waterproofing corners
Item No.
KERS20L
KERS28L
KERS20R
KERS28R
Type/Size
Left: 3/4" (20 mm)
Left: 1-1/8" (28 mm)
Right: 3/4" (20 mm)
Right: 1-1/8" (28 mm)
KERDI-SEAL-PS pipe seal with gasket
Item No.
KMS185/12
KMS185/20
KMS10185/12
KMS10185/20
Opening diameter/Quantity
1/2" (12.5 mm) / 1 unit
3/4" (20 mm) / 1 unit
1/2" (12.5 mm) / 10 units
3/4" (20 mm) / 10 units
KERDI-KM pipe seal
KM5117/22 7/8" (22 mm) / 5 units
KERDI-SEAL-MV mixing valve seal with gasket
KMSMV235/114 4-1/2" (114 mm) / 1 unit
4-1/2" (114 mm) / 10 units KMSMV10235/114
KERDI-FIX adhesive/sealant
Item No.
KERDIFIX/ color*
Volume
290 ml
Thickness
8 mil
8 mil
8 mil
8 mil
20 mil
4 mil
4 mil
4 mil
4 mil
4 mil
4 mil
4 mil
Thickness
4 mil
4 mil
4 mil
4 mil
Thickness
4 mil
4 mil
4 mil
4 mil
Thickness
4 mil
4 mil
4 mil
4 mil
Thickness
4 mil
4 mil
4 mil
4 mil
4 mil
4 mil
4 mil
PRODUCT & ORDERING INFO 41
4" Grate Options
Tileable Covering Support
Schluter ®
-KERDI-DRAIN
KERDI-DRAIN is a floor drain designed with a sloped, integrated bonding flange to provide a secure connection to KERDI and other bonded waterproof membranes at the top of the assembly.
Unique Features and Benefits:
- Appropriate for both mortar bed and KERDI-SHOWER-ST tray installations.
- Features a fully adjustable square grate and accommodates a wide range of tile thicknesses 1/4" to 1-1/4" (6 mm to 31 mm). Grate is available in stainless steel (E), stainless steel with oil-rubbed bronze finish (EOB), brushed brass anodized aluminum
(AMGB), brushed copper anodized aluminum (AKGB), and brushed nickel anodized aluminum (ATGB).
- Ideal for new construction and renovation work.
- Saves installation time and labor, as it eliminates the prep work required for a traditional two-step mortar pan.
- Integrated bonding flange ensures secure connection to KERDI at top of the assembly.
Anodized Aluminum Stainless Steel
6" Grate Options
Stainless Steel
(ECS)
Patent pending
Brushed nickel
(ATGB)
Brushed copper
(AKGB)
Brushed brass
(AMGB)
Stainless steel (E)
Oil-rubbed bronze
(EOB)
(6E) (6RE)
KERDI-DRAIN - Components - ABS, PVC or stainless steel flange
1
ABS or PVC flange
1
Stainless steel flange Includes
1 KERDI-DRAIN
Description
Drain with integrated bonding flange in ABS,
PVC or stainless steel, and grate assembly
Quantity
1
2
3
4
2
3
4
5
2
KERDI-KERECK-F Pre-formed waterproofing corners
4
3 KERDI-SEAL-PS
KERDI-SEAL-MV
5 KERDI-FIX
Pipe seal (3/4")
Mixing valve seal
Sealing and bonding compound (66 ml)
(Included with stainless steel flange only)
4 inside
2 outside
1
1
1
2" (50 mm) drain outlet
ABS flange PVC flange
Stainless steel flange
4" (100 mm) Square Grate
Stainless steel (E) KD2/ABS/E 1 KD2/PVC/E 1 KD2/E/E 1
Oil-rubbed bronze stainless steel (EOB)
Brushed brass anod. alu. (AMGB)
Brushed copper anod. alu. (AKGB)
Brushed nickel anod. alu. (ATGB)
Tileable (ECS)
KD2/ABS/EOB
KD2/ABS/AMGB
KD2/ABS/AKGB
KD2/ABS/ATGB
1
1
1
KD2/PVC/EOB
KD2/PVC/AMGB
KD2/PVC/AKGB
KD2/PVC/ATGB
1
1
1
KD2/E/EOB
KD2/E/AMGB
KD2/E/AKGB
KD2/E/ATGB
KD2/ABS/ECS 1 KD2/PVC/ECS 1 KD2/E/ECS 1
6" (150 mm) Square or Round Grate
Square Grate stainless steel (E)
Round Grate stainless steel (E)
KD2/ABS/6E
KD2/ABS/6RE
1
1
KD2/PVC/6E 1
KD2/PVC/6RE 1
1 Listed by ICC-ES (Report No. PMG-1204), UPC
® , CSA, and NSF.
KD2/E/6E 1
KD2/E/6RE 1
1
1
1
3" (75 mm) drain outlet
ABS flange PVC flange
6" (150 mm) Square or Round Grate
Square Grate stainless steel (E) KD3/ABS/6E
1
Round Grate stainless steel (E) KD3/ABS/6RE
1
KD3/PVC/6E
KD3/PVC/6RE
1
1
Stainless steel flange
KD3/E/6E 1
KD3/E/6RE 1
Also available:
Stainless steel flange with
2" (50 mm) threaded outlet.
Listed by ICC-ES (Report No. PMG-1204), UPC
® , CSA, and NSF.
42 PRODUCT & ORDERING INFO
Schluter ®
-KERDI-DRAIN - Adaptor Kits
KERDI-DRAIN ADAPTOR KITS are used to convert traditional clamping ring drains to integrated bonding flange drains when removal of the clamping ring drain is not practical.
Residential Commercial
Schluter ® -KERDI-DRAIN with residential adaptor ring and ABS flange
1
Includes
1 KERDI-DRAIN
Description
Drain, with integrated bonding flange and grate assembly
2 Adaptor ring ** For residential clamping ring drains
2 3 KERDI-KERECK-F Preformed waterproofing corners
3 4 5
4
5
6
KERDI-SEAL-PS
KERDI-SEAL-MV
KERDI-FIX
Pipe seal (3/4")
Mixing valve seal
Sealing and bonding compound (66 ml)
** D Schluter ® -Systems L.P., U.S. patent No. D593,641, other patents pending.
Quantity
1
1
4 inside and
2 outside
1
1
1
Schluter ® -KERDI-DRAIN with commercial adaptor ring and ABS flange
1 1
Includes
1 KERDI-DRAIN
Description
Drain, with integrated bonding flange in ABS or stainless steel, and grate assembly
2 Adaptor ring ** For commercial clamping ring drains
2 3
3
KERDI-FIX Sealing and bonding compound (66 ml)
** D Schluter ® -Systems L.P., U.S. patent No. D593,641, other patents pending.
Quantity
1
Residential
4" (100 mm) Square Grate
Stainless steel
(E)
Oil-rubbed bronze stainless steel (EOB)
Brushed brass anod. alu. (AMGB)
Brushed copper anod. alu. (AKGB)
Brushed nickel anod. alu. (ATGB)
Adaptor kit with standard
ABS bonding flange
KDAR/ABS/E
KDAR/ABS/EOB
KDAR/ABS/AMGB
KDAR/ABS/AKGB
KDAR/ABS/ATGB
C ommercial
Standard ABS bonding flange
Extended ABS bonding flange
4" (100 mm) Square Grate
Stainless steel
(E)
Oil-rubbed bronze stainless steel (EOB)
Brushed brass anod. alu. (AMGB)
Brushed copper anod. alu. (AKGB)
Brushed nickel anod. alu. (ATGB)
KDA/ABS/E
KDA/ABS/EOB
KDA/ABSL/E
KDA/ABSL/EOB
KDA/ABS/AMGB KDA/ABSL/AMGB
KDA/ABS/AKGB KDA/ABSL/AKGB
KDA/ABS/ATGB KDA/ABSL/ATGB
Tileable grate (ECS) KDA/ABS/ECS KDA/ABSL/ECS
6" (150 mm) Square or Round Grate
Square Grate stainless steel (E)
Round Grate stainless steel (E)
KDA/ABS/6E
KDA/ABS/6RE
KDA/ABSL/6E
KDA/ABSL/6RE
Stainless steel bonding flange
KDA/E/E
KDA/E/EOB
KDA/E/AMGB
KDA/E/AKGB
KDA/E/ATGB
KDA/E/ECS
KDA/E/6E
KDA/E/6RE
PRODUCT & ORDERING INFO 43
Schluter ®
-KERDI-LINE
KERDI-LINE is a low profile linear floor drain specifically designed for bonded waterproofing assemblies. KERDI-LINE can be installed adjacent to walls or at intermediate locations in showers, wet rooms, and other applications that require waterproofing and drainage. The floor can be sloped on a single plane to KERDI-LINE, which enables the use of large-format tiles and creates interesting design opportunities.
KERDI-LINE consists of a formed stainless steel channel body and a grate assembly that can be seamlessly adjusted to the thickness of the ceramic tile or stone covering from 1/8" to 1" (3 mm to 25 mm). Grate assemblies are available in three designs: closed, perforated, or tileable covering support.
Note: There are multiple selections to be made for this product. Start by selecting the appropriate flange length then proceed to grate selection accordingly, keeping in mind there are two frame heights with two grate options (A or B), and a frameless option (D).
= L
= L
1
Channel body with center outlet
Wall placement
8" - 20.3 cm
7/8" -
22 mm
2-1/4" -
57 mm
7/8" -
22 mm
4-23/32" - 120 mm
7/8" -
22 mm
2-1/4" -
57 mm
7/8" -
22 mm
Intermediate placement
5-15/32" - 137 mm
= L
= L
1
Channel body with off-set outlet
3/8" -
10 mm
1-27/32" -
47 mm
3/8" -
10 mm
2-1/8" - 54 mm
2" - 50 mm
= H = H
Closed (A)
2-29/32" - 74 mm
Perforated (B)
2-29/32" - 74 mm
Frameless Tileable (D) Patent pending
KERDI-LINE linear floor drain
Bonding flange Grate A Grate B Grate D
L = in. - cm
L
1
= in. - cm
19-11/16 - 50 21-11/16 - 55
23-5/8 - 60
27-9/16 - 70
31-1/2 - 80
35-7/16 - 90
39-3/8 - 100
25-5/8 - 65
29-9/16 - 75
33-1/2 - 85
37-7/16 - 95
41-3/8 - 105
Center outlet
KLV 60 E 50
Off-set outlet
-
Frame =
3/4" - 19 mm
Frame =
1-1/8" - 30 mm
KLAR 19 EB 50 KLAR 30 EB 50
Frame =
3/4" - 19 mm
KLB 19 EB 50
Frame =
1-1/8" - 30 mm
For use with bonding flange with center outlet
KLB 30 EB 50 KLDRE 50
For use with bonding flange with off-set outlet
-
KLV 60 E 60
KLV 60 E 70
KLV 60 E 80
KLV 60 E 90
-
KLVO 60 E 70
KLVO 60 E 80
KLVO 60 E 90
KLAR 19 EB 60
KLAR 19 EB 70
KLAR 19 EB 80
KLAR 19 EB 90
KLAR 30 EB 60
KLAR 30 EB 70
KLAR 30 EB 80
KLAR 30 EB 90
KLB 19 EB 60
KLB 19 EB 70
KLB 19 EB 80
KLB 19 EB 90
KLB 30 EB 60
KLB 30 EB 70
KLB 30 EB 80
KLB 30 EB 90
KLDRE 60
KLDRE 70
KLDRE 80
KLDRE 90
-
KLDRO E 70
KLDRO E 80
KLDRO E 90
KLV 60 E 100 KLVO 60 E 100 KLAR 19 EB 100 KLAR 30 EB 100 KLB 19 EB 100 KLB 30 EB 100 KLDRE 100 KLDRO E 100
43-5/16 - 110 45-5/16 - 115 KLV 60 E 110 KLVO 60 E 110 KLAR 19 EB 110 KLAR 30 EB 110 KLB 19 EB 110 KLB 30 EB 110 KLDRE 110 KLDRO E 110
47-1/4 - 120 49-1/4 - 125 KLV 60 E 120 KLVO 60 E 120 KLAR 19 EB 120 KLAR 30 EB 120 KLB 19 EB 120 KLB 30 EB 120 KLDRE 120 KLDRO E 120
51-3/16 - 130 53-3/16 - 135 KLV 60 E 130
55-1/8 - 140 57-1/8 - 145 KLV 60 E 140
59-1/16 - 150 61-1/16 - 155 KLV 60 E 150
-
-
-
KLAR 19 EB 130
KLAR 19 EB 140
KLAR 19 EB 150
-
-
-
KLB 19 EB 130
KLB 19 EB 140
KLB 19 EB 150
-
-
-
KLDRE 130
KLDRE 140
KLDRE 150
-
-
-
62-15/16 - 160 64-15/16 - 165 KLV 60 E 160
66-7/8 - 170 68-7/8 - 175 KLV 60 E 170
70-13/16 - 180 72-13/16 - 185 KLV 60 E 180
-
-
-
KLAR 19 EB 160
KLAR 19 EB 170
KLAR 19 EB 180
-
-
-
KLB 19 EB 160
KLB 19 EB 170
KLB 19 EB 180
-
-
-
KLDRE 160
KLDRE 170
KLDRE 180
-
-
-
KERDI-LINE is listed by ICC-ES (Report No. PMG-1204), UPC
® , CSA, and NSF.
Note: Purchase bonding flange and grate assembly separately.
44 PRODUCT & ORDERING INFO
KERDI-SHOWER-ST shower tray
KERDI-SHOWER-L/-LS shower trays
Curbs
Ramp
Benches
Schluter ®
-KERDI-SHOWER
KERDI-SHOWER prefabricated substrates are made of expanded polystyrene foam, for use in conjunction with the KERDI waterproofing membrane. KERDI-BOARD prefabricated substrates are made of Schluter ® -KERDI-BOARD, and are waterproof and ready for tile. A pre-cut section of KERDI matching the dimensions of the tray is included with the KERDI-SHOWER-ST for convenience. Prefabricated substrates provide an alternative to shower bases constructed of mortar and other shower elements constructed of framing and solid backing.
KERDI-SHOWER-ST shower tray for use with KERDI-DRAIN
ST-97
ST122
Item No.
ST-122/183
ST-183
Dimensions
38" x 38" (97 cm x 97 cm)
48" x 48" (122 cm x 122 cm)
48" x 72" (122 cm x 183 cm)
72" x 72" (183 cm x 183 cm)
ST-81/152 32" x 60" (81 cm x 152 cm)
ST-81/152 BR 32" x 60" (81 cm x 152 cm)
KERDI-SHOWER-L/-LS shower tray for use with KERDI-LINE
KSL 1000 S 39" x 39" (100 cm x 100 cm)
Drain Placement
Center
Center
Center
Center
Center
Off-center
Wall
KSL 1400 S
KSL 1000
KSL 1400
55" x 55" (140 cm x 140 cm)
39" x 39" (100 cm x 100 cm)
55" x 55" (140 cm x 140 cm)
KERDI-BOARD-SB shower bench
Item No.
KB SB 410TA
Dimensions
16" x 16" x 20" (41 cm x 41 cm x 51 cm)
KB SB 610TA
KB SB 970290RA
KB SB 1220410RA
24" x 24" x 20" (61 cm x 61 cm x 51 cm)
38" x 11-1/2" x 20" (97 cm x 29 cm x 51 cm)
48" x 16" x 20" (122 cm x 41 cm x 51 cm)
Wall
Center
Center
Shape
Triangular
Triangular
Rectangular
Rectangular
KERDI-BOARD-SC shower curb
Item No.
KB SC 970150115
KB SC 1220150115
Dimensions
4-1/2" x 48" x 6" (11.5 cm x 122 cm x 15 cm)
4-1/2" x 38" x 6" (11.5 cm x 97 cm x 15 cm)
KERDI-SHOWER-SC shower curb
Item No.
SC122
Dimensions
4-1/2" x 48" x 6" (11.5 cm x 122 cm x 15 cm)
KERDI-SHOWER-SR shower ramp
Item No.
SR122
Dimensions
48" x 15-7/8" (122 cm x 40 cm)
W
2
W
1
H
1
H
2
Schluter ®
-KERDI-BOARD-SN
KERDI-BOARD-SN prefabricated shower niche
Item No.
KB 12 SN 305 152 A
W
1
H
1
12" (305 mm) 6" (152 mm)
W
2
H
2
16" (406 mm) 10" (250 mm)
KB 12 SN 305 305 A 12" (305 mm) 12" (305 mm) 16" (406 mm) 16" (406 mm)
KB 12 SN 305 508 A1 12" (305 mm) 20" (508 mm) 16" (406 mm) 24" (610 mm)
KB 12 SN 305 711 A1 12" (305 mm) 28" (711 mm) 16" (406 mm) 32" (810 mm)
Depth Shelf
3-1/2"
(8.9 cm)
3-1/2"
(8.9 cm)
3-1/2"
(8.9 cm)
3-1/2"
(8.9 cm)
-
-
1
1
PRODUCT & ORDERING INFO 45
SHOWERPROFILE-S
SHOWERPROFILE-R
= H
2
H = 3/16" (5 mm)
or
3/8" (10 mm)
2%
= L
H = 1/2"
(12.5 mm)
25/32" (20 mm)
= H
7/8" (22mm) /
1-1/4" (32 mm)
H = variable
35 mm - 1-3/8''
= H
1
Schluter ® -Systems
Shower Profiles
SHOWERPROFILE-S tapered edging profile
Item No.
SPSA 50 EB/120
SPSA 50 EB/160
SPSA 50 EB/200
SPSB 100 EB/120
SPSB 100 EB/160
SPSB 100 EB/200
SPSB 125 EB/120
SPSB 125 EB/160
SPSB 125 EB/200
H
3/16" (5 mm)
3/16" (5 mm)
3/16" (5 mm)
3/8" (10 mm)
3/8" (10 mm)
H
1
1/4" (6 mm)
1/4" (6 mm)
1/4" (6 mm)
H
2
Length
1-3/16" (30 mm) 47-1/4" (1.2 m)
1-1/2" (38 mm) 63" (1.6 m)
1-13/16" (46 mm) 78-3/4" (2 m)
3/8" (10 mm) 1-11/32" (34 mm) 47-1/4" (1.2 m)
3/8" (10 mm) 1-1/2" (38 mm) 63" (1.6 m)
3/8" (10 mm) 3/8" (10 mm) 2" (50 mm) 78-3/4" (2 m)
1/2" (12.5 mm) 3/8" (10 mm) 1-11/32" (34 mm) 47-1/4" (1.2 m)
1/2" (12.5 mm) 3/8" (10 mm) 1-1/2" (38 mm)
1/2" (12.5 mm) 3/8" (10 mm) 2" (50 mm)
63" (1.6 m)
78-3/4" (2 m)
SHOWERPROFILE-R edging profile
Item No.
SPRA 23 EB/100
SPRA 23 EB/140
SPRA 33 EB/100
Height
29/32" - 1-3/8" (23 mm - 35 mm)
29/32" - 1-3/8" (23 mm - 35 mm)
1-5/16" - 1-25/32" (33 mm - 45 mm)
Length
39" (1 m)
55" (1.4 m)
39" (1 m)
55" (1.4 m) SPRA 33 EB/140 1-5/16" - 1-25/32" (33 mm - 45 mm)
KERDI-LINE-FC cover plate
Item No.
V / KLEB 35
Width
1-3/8" (35 mm)
KERDI-LINE-FC
Schluter ®
-SHOWERPROFILE-WS
SHOWERPROFILE-WS + -WSL
19 mm - 3/4"
SHOWERPROFILE-WS + -WSL
19 mm - 3/4"
SHOWERPROFILE-WS + -WSC
SHOWERPROFILE-WS + -WSC
Schluter ®
-SHOWERPROFILE-WSK
Schluter
®
-SHOWERPROFILE-WS
Satin anodized aluminum support profile
H = in. - mm Item No.
L = 39"- 1 m
5/16 - 8 SPWS 19 AE / 100
L = 8' 2-1/2" - 2.5 m
5/16 - 8 SPWS 19 AE
Schluter
®
-SHOWERPROFILE-WSC
Semi-circular lip
H = in. - mm Item No.
L = 39"- 1 m
5/16 - 8 SPWSC 16 GS / 100
L = 8' 2-1/2" - 2.5 m
5/16 - 8 SPWSC 16 GS
Schluter
®
-SHOWERPROFILE-WSL
Straight lip
H = in. - mm Item No.
L = 39"- 1 m
5/16 - 8 SPWSL 30 T / 100
L = 8' 2-1/2" - 2.5 m
5/16 - 8 SPWSL 30 T
ADA-Compliant
Note: SHOWERPROFILE-WS with the WSL straight lip insert is not ADAcompliant.
SHOWERPROFILE-WSK + -WSL
SHOWERPROFILE-WS K+ -WSC
52 mm - 2-1/6"
SHOWERPROFILE-WSK + -WSL
52 mm - 2-1/16"
SHOWERPROFILE-WSK + -WSC
Schluter ® -SHOWERPROFILE-WSK
Satin anodized aluminum support profile
H = in. - mm Item No.
L = 39"- 1 m
5/16 - 8 SPWSK 52 AE / 100
L = 8' 2-1/2" - 2.5 m
5/16 - 8 SPWSK 52 AE
Schluter
®
-SHOWERPROFILE-WSC
Semi-circular lip
H = in. - mm Item No.
L = 39"- 1 m
5/16 - 8 SPWSC 16 GS / 100
L = 8' 2-1/2" - 2.5 m
5/16 - 8 SPWSC 16 GS
Schluter ® -SHOWERPROFILE-WSL
Straight lip
H = in. - mm Item No.
L = 39"- 1 m
5/16 - 8 SPWSL 30 T / 100
L = 8' 2-1/2" - 2.5 m
5/16 - 8 SPWSL 30 T
Schluter ® -SHOWERPROFILE-WSK-EK
End cap
H = in. - mm
5/16 - 8
Item No.
EK / SPWSK 52 AE
ADA-Compliant
Note: SHOWERPROFILE-WSK with the WSL straight lip insert is not ADAcompliant.
SHOWERPROFILE-WSK/EK
46 PRODUCT & ORDERING INFO
3
1
5
2
4
7 8
6
Schluter ®
-KERDI-SHOWER-KIT
The KERDI-SHOWER-KIT is an all-inclusive package containing the components required to create a watertight shower assembly without a mortar bed.
Schluter ® -KERDI-SHOWER-KIT
1
2
3
6
7
8
4
5
Includes
KERDI 10 M
KERDI 12 M
Description
KERDI-SHOWER-ST Shower tray
KERDI-SHOWER-SC Shower curb 48" x 6" x 4-1/2"
Waterproofing membrane 3' 3" x 33' = 108 ft
Waterproofing membrane 3' 3" x 39' 4" =
2
128 ft 2
Quantity
48" x 48" 72" x 72" 32" x 60"
1
1
1
1
2
1
2
1
KERDI 20 M
KERDI-BAND
Waterproofing membrane 3' 3" x 65' 7" = 215 ft 2
Waterproofing strip 5" x 33' 1
1
2 1
KERDI-DRAIN Drain, with integrated bonding flange with 2" (50 mm) outlet
1 1 1
KERDI-KERECK-F Preformed waterproofing corners
KERDI-SEAL-PS Pipe seal (3/4")
KERDI-SEAL-MV Mixing valve seal
4 inside and 2 outside
1
1
72" - 183 cm
48" - 122 cm
48" x 48" (122 cm x 122 cm) Kit
Select material for drain (ABS or PVC) and grate finish
Item No.
KK122ABSECS
KK122ABSE
KK122ABSEOB
KK122ABSATGB
KK122ABSAKGB
KK122ABSAMGB
KK122PVCECS
KK122PVCE
KK122PVCEOB
KK122PVCATGB
KK122PVCAKGB
KK122PVCAMGB
Drain
Material
ABS
ABS
ABS
ABS
ABS
ABS
PVC
PVC
PVC
PVC
PVC
PVC
Grate finish
Tileable
Stainless steel 304 (1.4301 = V2A)
Oil-rubbed bronze stainless steel
Brushed nickel anodized aluminum
Brushed copper anod. alu.
Brushed brass anodized aluminum
Tileable
Stainless steel 304 (1.4301 = V2A)
Oil-rubbed bronze stainless steel
Brushed nickel anodized aluminum
Brushed copper anod. alu.
Brushed brass anodized aluminum
60" - 152 cm
72" x 72" (183 cm x 183 cm) Kit
Select material for drain (ABS or PVC) and grate finish
Item No.
KK183ABSECS
KK183ABSE
KK183ABSEOB
KK183ABSATGB
KK183ABSAKGB
KK183ABSAMGB
KK183PVCECS
KK183PVCE
KK183PVCEOB
KK183PVCATGB
KK183PVCAKGB
KK183PVCAMGB
Drain
Material
ABS
ABS
ABS
ABS
ABS
ABS
PVC
PVC
PVC
PVC
PVC
PVC
Grate finish
Tileable
Stainless steel 304 (1.4301 = V2A)
Oil-rubbed bronze stainless steel
Brushed nickel anodized aluminum
Brushed copper anod. alu.
Brushed brass anodized aluminum
Tileable
Stainless steel 304 (1.4301 = V2A)
Oil-rubbed bronze stainless steel
Brushed nickel anodized aluminum
Brushed copper anod. alu.
Brushed brass anodized aluminum
60" - 152 cm
32" x 60" (81 cm x 152 cm) Kit
Select material for drain (ABS or PVC) and grate finish
Item No.
KK81152ABSECS
KK81152ABSE
KK81152ABSEOB
KK81152ABSATGB
KK81152ABSAKGB
KK81152ABSAMGB
KK81152PVCECS
KK81152PVCE
KK81152PVCEOB
KK81152PVCATGB
KK81152PVCAKGB
KK81152PVCAMGB
Drain
Material
ABS
ABS
ABS
ABS
ABS
ABS
PVC
PVC
PVC
PVC
PVC
PVC
Grate finish
Tileable
Stainless steel 304 (1.4301 = V2A)
Oil-rubbed bronze stainless steel
Brushed nickel anodized aluminum
Brushed copper anod. alu.
Brushed brass anodized aluminum
Tileable
Stainless steel 304 (1.4301 = V2A)
Oil-rubbed bronze stainless steel
Brushed nickel anodized aluminum
Brushed copper anod. alu.
Brushed brass anodized aluminum
Note: Tray features off-center drain placement:
10" (25.4 cm) o.c. from end of tray.
32" x 60" (81 cm x 152 cm) Kit
Select material for drain (ABS or PVC) and grate finish
Item No.
KKB81152ABSECS
KKB81152ABSE
KKB81152ABSEOB
KKB81152ABSATGB
KKB81152ABSAKGB
KKB81152ABSAMGB
KKB81152PVCECS
KKB81152PVCE
KKB81152PVCEOB
KKB81152PVCATGB
KKB81152PVCAKGB
KKB81152PVCAMGB
Drain
Material
ABS
ABS
ABS
ABS
ABS
ABS
PVC
PVC
PVC
PVC
PVC
PVC
Grate finish
Tileable
Stainless steel 304 (1.4301 = V2A)
Oil-rubbed bronze stainless steel
Brushed nickel anodized aluminum
Brushed copper anod. alu.
Brushed brass anodized aluminum
Tileable
Stainless steel 304 (1.4301 = V2A)
Oil-rubbed bronze stainless steel
Brushed nickel anodized aluminum
Brushed copper anod. alu.
Brushed brass anodized aluminum
Note: The KERDI-SHOWER-KIT is also available without the drain. This kit contains the same components as the complete KERDI-SHOWER-KIT, except the KERDI-DRAIN which must be purchased separately. This kit allows you to select the drain that is best suited to your application (i.e. KERDI-DRAIN with 3" outlet or KERDI-DRAIN with adaptor ring).
PRODUCT & ORDERING INFO 47
Additional panels and accessories
Please refer to our Illustrated Price List for details.
Grooved panels
Profiles
L-shaped panels
Anchors
U-shaped panels
Washers, screws and adhesive tape
Schluter ®
-KERDI-BOARD
KERDI-BOARD is a multifunctional tile substrate and building panel, which can also be used for creating bonded waterproofing assemblies with tile coverings. It consists of an extruded polystyrene foam panel, with a special reinforcement material on both sides and fleece webbing for effective anchoring in thin-set mortar.
The boards are simply cut to size with a utility knife. The gridlines, which are printed on the surface, are helpful for neat and quick cuts and installation. Tiles can be installed directly over KERDI-BOARD using the thin-set method.
Schluter ® -KERDI-BOARD
Substrate and building panel
H =
Panel dimension: 32" x 48" (81 cm x 122 cm)
Item No.
1/2" (12.5 mm) KB 12 1220 812
Panel dimension: 48" x 64" (122 cm x 162.5 cm)
3/16" (5 mm) KB 5 1220 1625
3/8" (9 mm)
1/2" (12.5 mm)
KB 9 1220 1625
KB 12 1220 1625
Panel dimension: 48" x 96" (122 cm x 244 cm)
3/16" (5 mm) KB 5 1220 2440
3/8" (9 mm) KB 9 1220 2440
1/2" (12.5 mm)
5/8" (15 mm)
KB 12 1220 2440
KB 15 1220 2440
Panel dimension: 24-1/2" x 96" (62.5 cm x 244 cm)
3/4" (19 mm) KB 19 625 2440
1" (25 mm) KB 25 625 2440
1-1/2" (38 mm)
2" (50 mm)
KB 38 625 2440
KB 50 625 2440
Panel dimension: 48" x 120" (122 cm x 305 cm)
5/8" (15 mm) KB 15 1220 3050
DITRA and DITRA-XL are listed by cUPC
®
and evaluated by ICC-ES (Report Nos. ESR-2467 and
PMG-1204).
DITRA-HEAT and DITRA-HEAT-TB are evaluated by
ICC-ES (Report Nos. ESR-2467 and PMG-1204).
48 PRODUCT & ORDERING INFO
Schluter ®
-DITRA and
Schluter ®
-DITRA-HEAT
DITRA is a pressure-stable polyethylene uncoupling membrane, vacuum-formed in a cutback grid design, with an anchoring fleece laminated to its underside. DITRA is 1/8"
(3 mm) in height. DITRA-XL is 5/16" (7 mm) in height. DITRA-HEAT is a polypropylene membrane with a cut-back stud structure and an anchoring fleece laminated to the underside. The matting is 1/4" (5.5 mm) in height. DITRA-HEAT-TB is a polypropylene membrane with a cut back stud structure and a thermal break anchoring fleece laminated to the underside. The matting is 5/16" (8 mm) thick. The thermal break fleece reduces heat loss to the substrate to improve floor warming response time. The stud structure is specifically designed to secure DITRA-HEAT-E-HK electric floor heating cables.
Schluter
®
-DITRA
Item No.
Packaging
DITRA uncoupling and waterproofing membrane (1/8" - 3 mm thick)
DITRA 5M
DITRA 150
DITRA 30
3' 3" x 16' 5" = 54 ft 2 (1 m x 5 m = 5 m 2 )
3' 3" x 45' 9" = 150 ft 2 (1 m x 14 m = 14 m 2 )
3' 3" x 98' 5" = 323 ft 2 (1 m x 30 m = 30 m 2 )
DITRA-XL uncoupling and waterproofing membrane (5/16" - 7 mm thick)
DITRA-XL/175 3' 3" x 53' 3" = 175 ft 2 (1 m x 16.25 m = 16.25 m 2 )
Schluter ® -DITRA-HEAT
Uncoupling and waterproofing membrane
Item No.
DH5 12M
DH5 MA
Dimensions
3' 3" x 41' 1" = 134.5 ft 2 (1 m x 12.5 m = 12.5 m 2 )
3' 3" x 2' 7" = 8.6 ft 2 (1 m x 0.8 m = 0.8 m 2 )
D Schluter-Systems L.P., U.S. patent No. D706459, other patents pending.
Schluter ® -DITRA-HEAT-TB
Uncoupling and waterproofing membrane with thermal break
Item No.
DHTB810M
DHTB8MA
Patent pending
Dimensions
3' 3" x 33' = 108 ft 2 (1 m x 10 m = 10 m 2 )
3' 3" x 2' 7" = 8.6 ft 2 (1 m x 0.8 m = 0.8 m 2 )
Format
Roll
Sheet
Format
Roll
Sheet
Notes:
Schluter ®
-DITRA-TROWEL and
Schluter ®
-KERDI-TROWEL
Used to install DITRA and KERDI membranes. The DITRA-TROWEL features an
11/64" x 11/64" (4.5 mm x 4.5 mm) square-notched design while the KERDI-TROWEL features a 1/8" x 1/8" (3 mm x 3 mm) square-notched design.
Schluter ® -DITRA-TROWEL and Schluter ® -KERDI-TROWEL
Trowels used to install Schluter ® -DITRA and Schluter ® -KERDI membranes
Item No.
Notch Size Packaging
TRL-DIT6
TRL-KER6
11/64" x 11/64" (4.5 mm x 4.5 mm)
1/8" x 1/8" (3 mm x 3 mm)
6 units
6 units
NOTES 49
Notes:
50 NOTES
WARRANTY
Schluter
®
-Shower System 10-Year Limited Warranty
COVERAGE AND CONDITIONS: Subject to the conditions and limitations as stated hereinafter, Schluter ® -Systems* warrants that the
Schluter ® -Shower System (the “Products”)** will meet all composition and performance criteria for a period of ten (10) years from the date of purchase only when the Products are used and installed in accordance with the terms and conditions of the Schluter ® -Shower System Installation
Handbook and industry standard guidelines that are not in conflict with the Handbook in effect at the time of installation. Further, efflorescence is considered to be a natural occurrence with cementitious materials and is therefore not considered to be a defective condition and is not covered by this warranty. It is the responsibility of the owner/builder/installer to ensure the suitability of all building materials and all associated building materials for the owner’s intended use. It is recommended that the owner consult with an experienced and professional installer.
RESOLUTION: If the Products fail to meet this warranty, then the owner’s exclusive remedy and the sole obligation of Schluter ® -Systems, at its election, shall be to a) reinstall or replace the failed portion of the tile assembly or b) pay an amount not to exceed the original square foot cost of the installation of the tile assembly verified to be defective. Tile assembly is defined to include all Schluter ® -KERDI products, non-reusable tile surfaces, and the appropriate setting and grouting materials. Further, due to conditions beyond the control of Schluter ® -Systems (e.g., color and shade availability, discontinuation, normal wear and tear), Schluter ® -Systems cannot guarantee or warrant an exact match to the specific tile, stone, or other covering materials used in the installation. In such events, substantially similar materials may be substituted.
DISCLAIMER: THERE ARE NO WARRANTIES BEYOND THIS EXPRESSED WARRANTY AS STATED ABOVE. ALL OTHER WARRANTIES,
REPRESENTATIONS OR CONDITIONS, EXPRESSED OR IMPLIED, ARE DISCLAIMED AND EXCLUDED, INCLUDING WARRANTIES,
REPRESENTATIONS OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARISING BY STATUTE
OR OTHERWISE BY LAW OR FROM A COURSE OF DEALING OR USAGE OF TRADE. SCHLUTER ® -SYSTEMS EXCLUDES AND IN NO
EVENT SHALL HAVE ANY LIABILITY FOR LOST PROFITS OR ANY OTHER INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE, EXEMPLARY, OR
CONSEQUENTIAL DAMAGES, ARISING OUT OF OR OTHERWISE CONNECTED TO FAILURE OF THE PRODUCTS, NOR MISUSE OF THE
PRODUCTS OR FAILURE TO PROPERLY MAINTAIN THE SHOWER OR BATHTUB SURROUND. REGARDLESS OF ANY STRICT LIABILITY,
ACTIVE OR PASSIVE NEGLIGENCE OF SCHLUTER ® -SYSTEMS, AND REGARDLESS OF THE LEGAL THEORY (CONTRACT OR TORT
OR EXTRA-CONTRACTUAL OR OTHER), NOR FROM ACTS OF WAR, TERRORISM, FAULTY AND NEGLIGENT PENETRATION OF THE
SYSTEM, FIRES, EXPLOSIONS, ACTS OF GOD, INTENTIONAL ACTS OF DESTRUCTION OR ANY LOSSES DUE TO STRUCTURAL FAILURE
OR OTHER CAUSES UNRELATED TO THE PRODUCTS OR DELAYS, OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES.
THIS WARRANTY IS GIVEN IN LIEU OF ANY OTHER WARRANTY EXPRESSED OR IMPLIED. THE REMEDIES CONTAINED HEREIN ARE
THE ONLY REMEDIES AVAILABLE FOR BREACH OF THIS WARRANTY. THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS;
SOME STATES AND PROVINCES DO NOT ALLOW DISCLAIMERS OR OTHER RESTRICTIONS OF IMPLIED WARRANTIES, SO SOME OF
THE ABOVE DISCLAIMERS MAY NOT APPLY TO YOU.
TRANSFERABILITY: This Limited Warranty extends ONLY to the original end user (defined as original intended owner and user of the property/unit in which the installation is incorporated - herein referred to as “Owner”) and is not transferable or assignable, unless approved in writing by the Technical Director or an Officer of Schluter ® -Systems or otherwise prohibited by specific state or provincial law.
MODIFICATIONS TO WARRANTY: No changes or modification of any terms or conditions of this warranty are allowed unless authorized by written agreement and signed by the Technical Director or an Officer of Schluter ® -Systems.
EFFECTIVE DATE: This warranty shall supersede and replace any and all prior oral or written warranties, agreements, or other such representations made by or on behalf of Schluter ® -Systems relative to the Products or the application of the Products and shall apply to any installation occurring on or after January 1, 2013.
CLAIMS ON THIS LIMITED WARRANTY: To make a claim under this Limited Warranty, the Owner must provide Schluter ® -Systems with written notice within 30 days of any alleged defect in the Products covered by this Limited Warranty, together with date and proof of purchase of the Products, proof of the costs of the original installation and name and address of all installers, failing which this Limited Warranty shall be of no legal effect. Schluter ® -Systems reserves the right at its election and as a condition of this Limited Warranty to inspect the alleged failed and defective condition.
All U.S. Claims shall be sent to: All Canadian Claims shall be sent to:
Schluter Systems L.P.
Attn: Warranty Claims Dept.
Schluter Systems (Canada), Inc.
Attn: Warranty Claims Dept.
194 Pleasant Ridge Road
Plattsburgh, NY 12901-5841
21100 chemin Ste-Marie
Ste-Anne-de-Bellevue, QC H9X 3Y8
*For the purpose of this warranty Schluter Systems, L.P. shall provide the warranty for all products for end users located in the United States, and
Schluter Systems (Canada) Inc. shall provide the warranty for all products for end users located in Canada. This warranty is limited to sales of the Products made in and intended for use in the United States and Canada.
**Schluter ® -Shower System (the “Products”): The Products are defined to include all Schluter ® -KERDI products referred to in the
Handbook and used in the integrated Schluter ® -Shower System.
WARRANTY 51
advertisement
Key Features
- Bonded waterproofing system
- Sealed system
- Easy installation
- Versatile design
- Durable materials
- Moisture management
- Mold and mildew resistant
- Reduced installation time