Slant/Fin S-150-DP 150 MBH Natural Gas Boiler Specification

Slant/Fin S-150-DP 150 MBH Natural Gas Boiler Specification

Below you will find brief information for gas boiler Sentry S-34, gas boiler Sentry S-60, gas boiler Sentry S-90. The Sentry boiler is a high-performance, cast-iron gas boiler that offers a blend of efficiency and reliability. It is ideal for a wide variety of gas boiler requirements as a replacement or for new installations. It provides years of trouble-free, high efficiency operation, while providing easy installation especially in sites with low chimney connections or low overhead clearance. It comes with a lifetime limited warranty.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Slant/Fin Sentry S-34, Sentry S-60, Sentry S-90 product details | Manualzz
SENTRY
®
High performance, cast-iron gas boiler
DOE
SEPT. 2012
COMPLIANT
Lower profile
makes installations easy
The boiler you choose for your home now will affect your
family’s comfort_ and pocketbook_ for many years to come.
Sentry boilers provide a blend of efficiency and reliability
that will keep your home comfortably warm and your fuel
costs low year after year. A new Sentry boiler can save up
to 30% or more on fuel bills compared to a typical old boiler operating at 60% efficiency.
•
•
•
•
Input: 5models 34,000 to 150,000 Btu/hr
Low clearance
Intermittent ignition
Saves energy. AFUE to 84.4%
Sentry is ideal for a wide variety of gas boiler requirements as a replacement or for new installations. Its
advanced design provides years of trouble-free, high efficiency operation, while providing easy installation especially in sites with low chimney connections or low overhead clearance.
Sentry is a reliable natural draft boiler.
Sentry’s heat exchanger is made of quality cast-iron and
assembled with durable metal push nipples. It's so reliable
it comes with a lifetime limited warranty. And, Sentry boilers respond quickly to your thermostat’s call for heat, sending heat within moments to radiators throughout
your home.
S-34 shown
Since 1949
*See installation instructions for specific applications and clearances.
®
BOILERS & BASEBOARD
www.slantfin.com
Th
eO
n ly N
me
ame You Wan Heating Your Ho
t
Computer-aided design.
Highest quality manufacturing.
Superior components.
14
2
13
1.
2.
3.
4.
5.
6.
7.
12
11
1
4
3
Advanced design heat exchanger
Relief valve
Thermal pins
Pressure temperature gauge
Metal push nipples (Avoids leaks)
Insulated base
Long life burners
5
8.
9.
10.
11.
12.
13.
14.
Gas valve
Rollout safety switch
Circulator pump
Brand name controls
Insulated jacket
Integral draft hood
Reliable, motorized
vent damper
RATINGS FOR SENTRY BOILERS – NATURAL AND L.P. GAS
10
6
9
MODEL
NUMBER †
8
7
S-34
S-60
S-90
S-120
S-150
DOE
SEPT. 2012
COMPLIANT
SENTRY
®
High performance, cast-iron gas boiler
CSA
INPUT
(Btuh)
DOE
CAPACITY
(Btuh)
NET
AHRI
RATING
WATER
(Btuh)*
WATER
(Sq.Ft.)
34,000
60,000
90,000
120,000
150,000
29,000
51,000
76,000
101,000
125,000
25,000
44,000
66,000
101,000
109,000
167
293
440
587
727
MODEL S-34
Integral
Integral
Draft
Draft
Diverter
Diverter
1
Tapping
3 3
3
"/4"3
19
19/34/"4" 1919/419
/4"
MODELS S-60 to S-150
CC
B
84.0
84.4
84.2
84.1
83.4
8-1/8
11-1/8
14-1/8
17-1/8
20-1/8
14-5/8
17-5/8
20-5/8
23-5/8
26-5/8
4
4
5
6
7
CC
C
1 1/21"/2Supply
111/21"/2Supply
" Supply
1"1/Supply
2" Supply
Tapping
Tapping
Tapping
Tapping
A
INTERMITTENT
IGNITION
C-VENT
DIAMETER
INTEGRAL
DRAFT
DIVERTER
* Net ratings are based on a piping and pick-up allowance of 1.15. Slant/Fin should be consulted before
selecting a boiler for installation having unusual piping and pick-up requirements. Ratings must be reduced
by 4% at 2,000 feet elevation and an additional 4% for every additional 1,000 feet elevation over 2,000 feet.
†Type of gas: after model number, specify gas by name “Natural” or “Propane”.
Note: All Sentry boilers are tested and rated for capacity under the U.S. Dept. of Energy (D.O.E.) Test
Procedure for boilers.
3/4"
3/4"
to air
eliminating
3/4"
to to
airair
eliminating
3/4"
air
eliminating
3to
eliminating
Vent Damper*
Vent
Damper*
/4"(by
toothers)
air eliminating
Relief Valve
Relief
Valve
system
Damper*
system
(by
others)
Vent
Damper* VentVent
Valve
Relief
Valve Relief
system
(by others)
Damper*
system (by others)
Relief Valve
system
(by others)
Pressure/Temp.
Pressure/Temp.
Pressure/Temp.
Pressure/Temp. Pressure/Temp.
Gauge
Gauge
Gauge
Gauge
Gauge
CC
DIMENSIONS-Inches
EFFICIENCY
AFUE%
Integral
Integral
Integral
Draft
Draft
Draft
Diverter
Diverter
Blocked Vent
Blocked
Vent
Diverter
Vent
77
Blocked
Vent Blocked
Vent
1616
Safety Blocked
Switch
Safety
Switch
Switch
Safety
Switch Safety
Safety Switch
3 3
33
/4"/4Drain
"3/Drain
" Drain /4"/4Drain
4" Drain
front panel)
AA 1 AA A
1
6 6/21"/2" B6 6/21"/2"1 B
B 6 /2" B B
FRONT VIEW
front panel)
Vent Damper*
Vent
Damper*
Relief Valve
Damper*
Relief
Valve
Vent
Damper* VentVent
3 3
Valve
Damper*
33
Relief
Valve Relief
Relief Valve
/4"/4"
to3air
eliminating
/4"/4"to toairaireliminating
to air
eliminating
eliminating
/4"(byto
air eliminating
system
others)
system
(by
others)
system
(by
others)
system (by others) system (by others)
CC
C
Supply Piping
Supply
Piping
Piping
Supply
Piping Supply
Supply Piping
(by(by
others)
(by(by
others)
others)
others)
(by others)
Pressure/Temp.
Pressure/Temp.
Pressure/Temp.Pressure/Temp.
Pressure/Temp.
Gauge
Gauge
Gauge
Gauge
Gauge
3 3
33
/
4
/4"/4Drain
"3/Drain
" Drain "/4Drain
4" Drain
111/21"/2Supply
111/21"/2Supply
" Supply
1"1/Supply
2" Supply
Tapping
Tapping
Tapping
Tapping
Tapping
3 3
3
"/4"3
19
19/34/"4" 1919/419
/4"
Ignition
Ignition
Control
Control
7 7
28
/"167"/16"
28/ / " " 2828/16
28
Rollout Safety
Rollout
Safety
Safety
Rollout
Safety Rollout
Rollout
(behind Safety
Switch
(behind Switch
Switch
(behind
Switch
(behind front
panel)
Switch (behind
front panel)
front panel)
Rollout Safety
Rollout
Safety
Safety
Rollout
Safety Rollout
Rollout
(behind Safety
Switch
(behind Switch
Switch
(behind
Switch
(behind front
panel)
Switch (behind
front panel)
front panel)
front panel)
Since 1949
®
frontA
panel)
A
BB
Aquastat
Aquastat
Relay
Relay
Aquastat
Aquastat
Aquastat
Relay
Relay
Relay
Ignition
Ignition
Ignition
Control
Control
Control
Circulator:
Circulator:
Circulator:
Circulator:
4"1 Circ. Circulator:
Flange
111
/4"
Flange11/1
1/Circ.
/4" Circ.
Flange
4" Circ. Flange
11/4"
Circ. Flange
11/12"1/Return
Tapping
111
/2"
Tapping
1/Return
2" Return
Tapping
2" Return Tapping
11/2" Return Tapping
Trap
Sediment Trap Sediment
Sediment Trap
Sediment Trap (required)
Sediment Trap
(required)
(required)
(required)
(required)
Combination
Combination
Combination Combination
Combination
Gas
Valve
Gas
Valve
Gas
Valve
(Dotted piping (Dotted piping
Gas
Valve
Joint
Union
by others.)
Union
by others.)
Joint
Union Joint
Joint Union
Ground
Ground
piping
tapping
1/2")Valve
Gas
(Dotted
piping (Dotted
(gas tapping 1/2")(gas
Ground
Ground
tapping
1/2")
(Dotted piping
others.)
(gas tapping 1/2") (gas (gas
by others.)
Ground by by
Union
tapping 1/2") Joint
others.)
RIGHT SIDE VIEW
Blocked Vent
Blocked
Vent
Vent
Blocked
Vent Blocked
Vent
Safety Blocked
Switch
Safety
Switch
Switch
Safety
Switch Safety
Safety Switch
Aquastat
Aquastat
Aquastat
Aquastat
Aquastat
Relay
Relay
Relay
Relay
Relay
Ignition
Ignition
Ignition
Ignition
Ignition
Control
Control
Control
Control
Control
7 7
7
/16/"167"
" " 3232
32
32/716/16
"
32 /16Circulator:
Circulator:
Circulator: 1 Circulator:
4"1 Circ. Circulator:
Flange
/4"
Flange1 /1
111
1/Circ.
/4" Circ.
Flange
4" Circ. Flange
Circ. Flange
11/4"
1/2" Return
1
Tapping
111
/2"
Return
Tapping
1/2" Return Tapping
11/2" Return
Tapping
11/2" Return Tapping
AA
A
BB
B
Trap
Sediment Trap Sediment
Sediment Trap
Sediment Trap (required)
Sediment Trap
(required)
(required)
(required)
(required)
Combination
Combination
Combination Combination
Combination(Dotted
Gas
Valve
piping
Gas
Valve
Ground
piping (Dotted
Ground
Gas
Valve
(Dotted piping
Ground
Gas
Valve
(Dotted piping
Ground
tapping
1/2")Valve
Gas
(Dotted piping
others.)
(gas tapping 1/2")(gas
Groundby by
by others.)
Joint
tapping
1/2")
Union
others.)
(gas tapping 1/2") (gas Joint
byUnion
others.)
Union
(gas tapping 1/2") Joint
Joint Union
U.S.A.
Slant/Fin Corporation • 100 Forest Drive
Greenvale, NY 11548 • 516-484-2600
www.slantfin.com
Joint Union
by others.)
Canada
Slant/Fin LTD/LTEE • 6450 Northam Drive
Mississauga, Ontario L4V 1H9 • 905-677-8400
www.slantfin.ca
BOILERS & BASEBOARD
Th
eO
n ly N
me
ame You Wan Heating Your Ho
t
©2012 Slant/Fin Corp. Publication S-10cv Printed in U.S.A. 912

advertisement

Key Features

  • High performance
  • Cast-iron heat exchanger
  • Intermittent ignition
  • Up to 84.4% AFUE
  • Lifetime limited warranty
  • Low clearance
  • Easy installation
  • Natural draft

Frequently Answers and Questions

What is the input of the Sentry S-34 boiler?
The Sentry S-34 boiler has an input of 34,000 Btu/hr.
What is the efficiency of the Sentry S-60 boiler?
The Sentry S-60 boiler has an efficiency of 84.4% AFUE.
How does the Sentry boiler respond to heating needs?
Sentry boilers respond quickly to your thermostat's call for heat, sending heat within moments to radiators throughout your home.

Related manuals

Download PDF

advertisement