Below you will find brief information for LED Flood Light FFLED18, LED Flood Light FFLED18W, LED Flood Light FFLED18P, LED Flood Light GDFFLED18W, LED Flood Light GDFFLED18P, LED Flood Light LFFLED18, LED Flood Light LFFLED18W, LED Flood Light PCS, LED Flood Light PC, LED Flood Light PCS2 and LED Flood Light PC2. This document describes the installation and wiring process for the RAB FFLED18 LED Flood Light. The fixture is designed for both 120V and 277V operation, and includes instructions for dimming and photocell options. The instructions also cover the mounting process and provide troubleshooting tips. The fixture is designed to be mounted on a junction box or landscape post and features a swivel arm for vertical aiming adjustment.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
FFLED18 INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
LOCATION
1. Seal arm thread using teflon tape or silicone sealant.
2. Secure the LED Flood to a 1/2” NPS hole in a junction box or landscape post.
3. Plug all unused holes and seal threads with silicone.
4. The swivel arm on the LED Flood allows 140º - 150º of vertical aiming adjustment depending on mounting location.
WIRING
Universal voltage drivers permit operation at 120V to
277VAC, 50 or 60 Hz, except fixtures factory ordered with a 120V photocell (/PC), 277V photocell (/PC2), 120V swivel photocell (/PCS), 277V swivel photocell (/PCS2)
1. Connect the BLACK fixture lead to the (+) LINE supply lead.
2. Connect the WHITE fixture lead to the (-) COMMON supply lead.
3. Connect the bare copper Ground wire from fixture to supply ground.
0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V thru
277V, 50 or 60 Hz. For 0-10V Dimming, follow the wiring directions as in fig. 2.
1. For Junction Box Mount, feed wires through silicone wiring plug into the junction box.
2. Connect the black fixture lead to the (+) LINE supply lead.
3. Connect the white fixture lead to the (-) COMMON supply lead.
4. Connect the GROUND wire from fixture to supply ground.
Do NOT connect the GROUND of the dimming fixture to the output.
5. Connect the purple fixture lead to the (V+) DIM lead.
6. Connect the gray fixture lead to the (V-) DIM lead.
7. Cap the yellow fixture lead, if present. Do NOT connect.
FFLED18 INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
GUARD OR SHIELD INSTALLATION
Wire Guard and Poly Shield mount with (4) #8-32 Stainless
Steel Screws. Screws are provided with accessory. See figure 1 for Guard. See figure 2 for Shield
1. Line up guard with pre-existing, pre-drilled holes in frame as shown, tighten screws.
Stainless Steel Screws (4)
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.
1. Clean glass lens with non-abrasive glass cleaning solution.
2. Do not open the fixture to clean the LED. Do not touch the LED.
TROUBLESHOOTING
1. Check that the line voltage at the fixture is correct. Refer to wiring directions.
2. Be sure the fixture is grounded properly.
3. Is the photocell, if used, functioning properly?
Figure 2
Stainless Steel Screws (4)
GUARD & SHIELD INSTALLATION
The Wire Guard and Poly Shield can be mounted on the same fixture with (4) #8-32 screws as shown below.
ACCESSORIES AND REPLACEMENT
PARTS
Chrome Wire Guard: GDFFLED18W
Poly shield: GDFFLED18P
Lens & Door Replacement: LFFLED18 (bronze)
Patent: US: pat D643,147, CN: ZL201130171304.1, MX: 36757; CA: D RAB Lighting, Inc., TW: Pat. pending
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
©2016 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
FFLED18 IN 0916
Easy Installation & Product Help
Tech Help Line
Call our experts 888 RAB-1000 rabweb.com
Visit our website for product info email
Answered promptly [email protected]
advertisement
Key Features
- 120V and 277V operation
- Dimmable
- Photocell options
- Swivel arm for aiming
- Junction box or post mounting
- Easy installation instructions
- Troubleshooting tips
- Universal voltage drivers
- Stainless steel screws included