0803 A

6-PIN CONNECTOR

for Optional Functions

MOUNTING INSTRUCTIONS

■ MOUNTING

1. Take the mounting bracket off of the monitor unit.

2. Cut out the cable knock-out, as shown by the dotted lines.

3. Plug the 6-pin connector into slot.

4. Connect the wires to the terminal block. Attach the protection shield.

5. Attach the mounting bracket to a box. Mount the monotor unit onto the bracket.

1 2 3

4 5

Strip jacket of cable. Put all the wires neatly into slot to avoid damage by pinching.

FOR MODELS

MK-1GD, MK-1HD,

MK-2MCD, MK-2HCD

MK-2MCD

MK-1GD, MK-2MCD

{

{

{

FUNCTION (WIRE)

Ext. device control (Gray) porch light, etc.

b1 b2

∗RY-3DL

∗RY-3DL

VIDEO -

VIDEO +

(Gray)

(Orange)

(Yellow)

(White)

(Blue)

AIPHONE CO., LTD., NAGOYA, JAPAN

AIPHONE CORPORATION, BELLEVUE, WA, USA

AIPHONE EUROPE N.V., ANTWERP, BELGIUM

1 2 3 4 5 6 http://www.aiphone.com/

Printed in Thailand

MK-DBC

MK-D

Light

6PIN CONNECT OR WIRING DIAGRAM for MK-2MCD & MK-1GD

MONITOR

TV (75 ohm)

MK-DGC

Sub

MK-2HCD

4

EL-9S

EL-9S

2

2

RY-3DL

2

2

PT

5

2

MAW-B

PS24

PS18

3

4

Sub

MK-2HCD

Master

MK-2MCD

RY-3DL

EL-9S

EL-9S

L2

C2

AC Trans.

L3

C3

L1

C1 D1

E

D2 b3 b2 b1

(MK-DGC 1 )

(MK-DGC 2 )

Light

Local switch

L

DOOR1

1A1

1A2

SUB

B1

B2

(MK-2HCD)

DOOR2

2A1

2A2 MONITOR

TV (75 ohm)

BLUE

WHITE

VIDEO +

VIDEO–

YELLOW

ORANGE

GRAY

GRAY

DC18V

+

(MK-2HCD)

+

Contact rating:

0.5A (DC 30V. AC 125V)

PS18

NTSC

RLSE.

L

L

PS24

WHITE

RED(+)

BLACK(–)

ORANGE

ORANGE

MAW-B

NOTE: YELLOW & ORANGE wire provides selective door release control with RY-3DL adaptor. Works for MK-2MCD only.

PS18 : PS-1820DIN, PS-1820S, PS-1820UL (2A) PS24 : 24V DC power supply for MAW-B or Relay

locally available.

advertisement

Key Features

  • 6-pin connector for optional functions
  • Intercom system with door entry feature
  • External device control with optional functions
  • Supports various models, including MK-1GD, MK-1HD, MK-2MCD, MK-2HCD, MK-D, MK-DBC, and MK-DGC
  • Easy installation and mounting
  • Reliable performance and quality construction
  • User friendly interface for hassle-free operation

Frequently Answers and Questions

How is the 6-pin connector used for optional functions, and what are the capabilities of these optional functions?
The 6-pin connector allows you to connect external devices to the intercom system. These devices can include various functions such as porch light control, door release control, etc. You can find more information on the supported devices in the wiring diagram of the manual.
What models of intercom systems are compatible with this 6-pin connector?
The 6-pin connector is compatible with the following intercom models: MK-1GD, MK-1HD, MK-2MCD, MK-2HCD, and MK-D.
How do I connect the wires to the terminal block?
You should strip the jacket of the cable and put all wires neatly into the slot. Connect the wires to the terminal block and attach the protection shield. Follow the instructions carefully to ensure proper and safe connection.

Related manuals

Download PDF

advertisement