CAS ELECTRICS CO.,LTD CL7200 Series Service Munual Rev. 2014. 12. 17 1 CAS ELECTRICS CO.,LTD 1. Proper Operation 1.1 Introduction Thank you for purchasing the CAS CL7200 series price computing printer scale. We have designed this equipment with advanced features, high quality construction, and user-friendly menu driven programming. We are confident that you will find the CAS CL7200 series scale will meet all of your most demanding needs. Sales data is easily acquired through many of the available reports which are quickly accessible through the on-screen menus. Also available: High speed printer (4 inch per second), 53 preset keys (106 using the SHIFT key or double click) per department, and several operation modes that enable you to control & access to the scale. For larger operations, CL7200 series has in-store network that can link-up to 32 scales. RS-232 port, ethernet port, and wireless connection enable to export and import program data for time-save mangement. On-time operation possible because of PLU and all other data files are kept locally in each scale’s memory bank; the scale’s speed is the same as a stand-alone unit in a network. The CL7200 series can use with both ticket and label. Auto measuring system enhances use any types of roll paper. (Just entering a label’s length and width dimensions, you can use practically any roll) Also cartridge loading mechanism helps to refill the label roll easyly. Also you can print logos, templates, NutriFacts panels, ingredient messages, advertisement lines, and more to promots your store. Remember, for proper installation and maintenance please read the CL7200 series Manual before use. A wide variety of supplies, accessories, and expansion options are available through CAS Corporation for whatever your new and increasing demands may require The CL7200 series also comes with the SP-2 software package. This software runs on any PC using the 95/98/2000/XP Windows OS. You can design your own label formats on your computer screen and save them to your hard drive. With this percise interface, the labels you see on-screen appear exactly on the printer. You can also manage all of the CL7200’s programs and options like pricing, PLU programming, etc. You can upload data from a CL300 series or download data. This is ideal solution for an emergency scale backup system. All this and many more features are packed into the SP-2 software package. SP-2 software package enhances your business next level. 2 CAS ELECTRICS CO.,LTD 1.2 Model and Specificationl Model CL7200 Series Capacity 15Kg 30Kg Interval 2g/5g 5g/10g Max Tare -5.998Kg -9.995Kg U-Type S-Type Display Fornt : 10.2”TFT LCD (800x480) Rear : 7” 15” TFT LCD (1024x768) TFT LCD (800x480) Zero Pass Range 1~50% (default 10%) Re-Zero Range 1~50% (default 2%) Overload Range Max Capa. ~ Max Capa. + 255d (default Max+9d) A/D Conversion Rate Measurement type Platter type Key Approx. 8/sec Load cell SUS PLU Key : 72 Speed Key Printing Resolution Label Size Barcode Type S-Type PLU Key : 144 Function Key: 36 PLU Key : 144 PLU 1~99999 3000 Ingredient 510 Char 1~999 999 user defined Barcode Format 1~99 99 Department 1~99 99 Tax Type 1~9 9 Group 1~99 99 Clerk 1~99 99 Discount - Origin 1~499 499 Data Table Report PLU Key : 72, Function Key: 36 U-Type 99 Traceability 1~99 99 Slaughter House 1~99 99 Cutting Hall 1~99 99 Traceability Country 1~99 99 Label Format Default :45, User:20 Bitmap 14 14 Customer 1~99 99 Quantity Symbol 1~8 8 Scroll Message 1~9 9 Pay Type 0~8 8 Sales Message 1~99 99 Nutrifact 1~500 500 Tare Table 1~99 99 Currency 1~4 4 X1/X2, Z1/Z2, Scale, PLU, Misc. PLU, Group, Department, Hourly, Clerk Report 202 dpi Width: 40mm ~ 60mm, Length: 20mm ~ 200mm EAN13, EAN13A5, EAN8, I2OF5, UPCA, UPC13, CODE39, CODE93, CODE128, CODABAR, Offer varoius sizes of label format, e.g Small, Middle, Large Size, and on the label format, also offers Font varioous types of fonts, such as Italic,Bold,Underline,Throgh Line, Double through line, Reverse,shadow, outline etc. Printer Type Dimensions Direct Thermal Print U-Type 409 x 500 x 370 mm P-Type 409 x 486 x 545 mm U,S TYPE Tray : 380 x 250 mm 3 CAS ELECTRICS CO.,LTD 1.3 Environmental Conditions & Safety 1) Please avoid the following hostile conditions Temperatures below or exceeding: Ungrounded electrical outlet Unstable or flimsy surface Shared electrical outlet -10° C ~ 40° C (14° F ~ 104° F) Excessive vibration Wind or fans functioning in direct contact with weighing platform. Direct sunlight Dust or dirt High humidity Poor ventilation 2) Environmental Protection The scale should be installed in a dry and liquid free environment. When the scale is installed in a high humidity or wet-type environment, be sure to avoid spilling or spraying directly on any surface of the scale. 3) Personal Safety It is very important to be aware of personal safety whenever maintaining or operating this equipment. We have tried to place warning labels and other indicators at the actual location on the equipment where the danger is most likely to occur. Warnings and cautions that are necessary for the safe operation of the scale are contained in this manual. Please, make sure to read carefully ALL warnings and cautions before operating the scale. 4) Observe the following safety precautions Shut the scale OFF and unplug the scale whenever you are changing the label roll or whenever working in the printer bay. The outlet that the scale is plugged into, should be properly grounded. Whenever connecting or disconnecting ANY cables from the scale, be sure to hold the cables by the end connector. Failure to do so may cause a short circuit. Maintain a static-free work area. The outlet used must have the proper voltage ratings. 4 CAS ELECTRICS CO.,LTD 1.4 Leveling and Footer Location 1) Location This scale must be placed on a flat and stable surface. Please keep the scale away from the direct path of oscillating fans, ventilation systems, or strong drafts as these air disturbances can be picked-up by the scale’s very sensitive weighing platform and may cause incorrect weight readings. 1.1) General Footer Factory setting (Footer location is following picture) 1.2) Short Case Footer Unscrow the footer and place in center hole for narrow place. 5 CAS ELECTRICS CO.,LTD 2) Leveling If the scale is not properly leveled, please adjust the 4 adjustable legs at the bottom of the scale. Turn the legs clockwise or counterclockwise so as to center the bubble of the leveling gauge inside the indicated circle. Turning the adjustable legs counter-clockwise (viewed from top of scale) will lower that part of the scale. Turning the adjustable legs clockwise (viewed from top of scale) will raise that part of the scale. (See Fig.) 6 CAS ELECTRICS CO.,LTD 1.5 Power Outlet and Requirements Power Source : AC 100~240V, 50/60Hz, 1.5A Power consumption : Max 90W CL7200 series’s outlet is on bottom of scale. Power Outlet Power Switch The CL7200 series is designed to be used almost anywhere in the world! Like the many appliances of today, the CL7200 series is designed with an automatically switching power supply. This allows operation when connected to an AC source from 100V to 240V at 50/60Hz with 5% tolerance. NOTE: Please make sure that the power lines used for the CL7200 series are dedicated lines with No high-noise devices (such as compressors, motors, etc) running on it. Also, make sure that the wiring to the electrical socket is correct. If you are uncertain as to the state of your work’ electrical lines, please contact a certified electrician.) Once you are sure as to the safety of the electrical line, make sure to ONLY plug the scale into a 3- prong outlet. The third prong is a safety ground and an electrician should properly wire this if it is not correct or if you are unsure. Failure to this CAN result in electrical shock from use of this or any electronic scale. 3) Do not use any 3-prong to 2-prong adapters or break-off the third prong from the CLP power cord. The third prong is necessary and must be properly connected. 4) If you have any problems or questions regarding this matter, make sure to contact the CAS Service Department. 7 CAS ELECTRICS CO.,LTD 2. Classification 2.1 Scale Overview CL7200 has 2 differrnt type Standard Type, Self Type. ■ Standard U-Type ■ Self-Type 8 CAS ELECTRICS CO.,LTD 2.2 Display and Key There is LCD(Front:800x480, Rear: 800x480) display on CL7200. LCD display indicates program tare, weight, unit price, total price. Underbar inicates stable, net, zero, auto, save, prepack, D/C, shift, data transfer. LCD display shows menu massages for program mode. ■ CL7200-U - CL7200 Sale mode(Operator View) - Rear 9 CAS ELECTRICS CO.,LTD ■ CL7200-S 10 CAS ELECTRICS CO.,LTD ■ Indicators B, P, R, H - TYPE SYMBOLS G - TYPE DESCRIPTION D - TYPE ST ST STABLE Stable weight indicator ▶0◀ ZR ▶0◀ Zero weight indicator NET AUTO SAVE PREPACK D/C SHIFT TR NET AT SV PRK DC SH TR NET AUTO SAVE PREPACK D/C SH M Net weight indicator Print Mode indicator Auto clearing status indicator Auto clearing status and Print mode indicator Discount status indicator Speed key shift status indicator Data transmission status indicator Master status indicator S Slave status indicator LN Ethernet Connection Status 11 CAS ELECTRICS CO.,LTD 2.3 Printer •Cartridge type print mechanism •High quality ROHM printer head (50km/5x107pulses) •Improved a rotating force by using 2 independent motors •Large compartment for 120mm paper roll •High speed at 100 mm/sec. •5 speed ranges for paper roll quality adjustment •Supports Paper •Labels, •Continuous strip labels, •Lineless paper 12 CAS ELECTRICS CO.,LTD 2.4 Commuication ■ Standard ① RS232 ② Cash Drawer ③ Ethernet ④ USB Device ⑤ USB Host x 2 ■ Options ⑥ Wireless Ethernet Module ⑥ Wireless Ethernet Module ⑤ USB Host x 2 ④ USB Device ① RS232 ③ Ethernet ②Cash Drawer 13 CAS ELECTRICS CO.,LTD 3. Getting Started 3.1 Sealing Method ■ Method 1 ■ Method 2 ■ Method 3 ■ Method 4 14 CAS ELECTRICS CO.,LTD 3.2 Installation of the Label Roll ■ Label Specifications Outer diameter of roll : 100mm Inner diameter of roll : 40mm Width of receipt roll : 40, 50, 60mm Width of label roll : 60mm(MAX) ■ Print Area Width of label : 60mm(MAX) Length of label : 120mm(MAX) To install the label roll at ANY time you must follow the directions in this section: 1) Press the ON/OFF key and make sure that the display is completely off. Open the printer’s sideaccess panel. (See fig.1) 2) Lift up TPH lever as fig 2. 15 CAS ELECTRICS CO.,LTD 3) Remove cartridge as fig. 3. 4) Remove Pick-Up Spool assembley and paper guide from the cartridge as fig. 4. 4 5) Place the label in the scale as fig. 5 5 6) Press the FEED key. NOTE: For auto label calibration press FEED key two or three times * If label position is not correct, you have to check the followings: a. Label size (Label setting menu) b. Feed Adjustment (Feed adjustment menu) c. Senseor calibration (Sensor Calibration menu) 16 CAS ELECTRICS CO.,LTD 3.3 Program Menu and Tree 3.3.1 How to access PROGRAM MODE You can see the Program Menu screen by pressing the MENU key. - Lower end of left number represents the Page number of Main Menu and Lower end of right number represents the Page number of Sub Menu. - Left number, based on “/”, means Present Page and Right means the number of total pages. You can enter the page where you want by pressing the arrow keys. 17 CAS ELECTRICS CO.,LTD 3.3.2 Program Menu Tree CODE Menu CODE 1110 1120 Sub Menu І CODE Sub Menu Ⅱ Change Price New/Edit 1130 Discount 1131 New/Edit 1132 1133 List Delete 1137 1138 1139 1100 1150 1160 1170 1300 Copy 1142 Delete PLU 1140 1200 1141 PLU data table Ⅰ PLU data table Ⅱ 1147 1148 1149 Management 1143 Move 1144 Inhibit 1145 PLU Sale Count Delete by PLU(DC) Delete by Dept(DC) Delete All Delete by PLU No. Delete by Dept. No. Delete All List Speed Key 1161 1162 Edit Speed Key Reset all setting 1211 1212 1213 1221 1222 1223 1241 1242 1243 1251 1252 1253 1261 1262 1263 1271 1272 1273 1274 1281 1282 1283 1311 1312 1313 1321 1322 1323 1331 1332 1333 New/Edit department List department Delete department New / Edit group List group Delete group New / Edit Sales Message List Sales Message Delete Sales Message New / Edit origin List origin Delete origin New / Edit barcode List barcode Delete barcode New / Edit tare List tare Delete tare Tare key New / Edit Unit Symbol List Unit Symbol Delete Unit Symbol New / Edit Ingredient List Ingredient Delete Ingredient New / Edit Nutrifact List Nutrifact Delete Nutrifact New / Edit traceability List traceability Delete traceability Sample Printing 1210 Department 1220 Group 1240 Sales Message 1250 Origin 1260 Barcode 1270 Tare 1280 Unit Symbol 1310 Ingredient 1320 Nutrition facts 1330 Traceability 18 CAS ELECTRICS CO.,LTD CODE 1300 1400 1500 1600 Menu PLU data table Ⅱ Store data table Global setting CODE Sub Menu І 1340 Country 1350 Slaughter House 1360 Cutting Hall 1410 Store 1420 Customer 1430 Scroll Message 1440 Currency 1450 Job Batch Schedule 1460 Scanner 1470 1510 1520 Label Format Key Table Label Format Barcode 1530 Discount 1540 Tax 1610 X1 report Report 1620 1630 CODE 1341 1342 1343 1351 1352 1353 1361 1362 1363 1411 1412 1413 1431 1432 1433 1441 1442 1443 1451 1452 1453 1461 1462 1463 1464 1531 1532 1533 1534 1541 1542 1611 1612 1613 1614 1615 1616 1617 Sub Menu Ⅱ New / Edit country List country Delete country New / Edit slaughter house List slaughter house Delete slaughter house New / Edit cutting hall List cutting hall Delete cutting hall New / Edit Store List Store Delete Store New / Edit Customer List Customer Delete Customer Configuration Edit Scroll Message List Scroll Message New / Edit Currency List Currency Delete Currency New / Edit Schedule List Schedule Delete Schedule New / Edit Conv Table List Conv Table Delete Conv Table Scanner Config Priority setting Weight discount Count discount PCS discount Set Global Tax Global Tax No. Scale PLU Misc. PLU Group Department Hourly Clerk Z1 report X2 report 1631 1632 1633 1634 Scale PLU Misc. PLU Group 19 CAS ELECTRICS CO.,LTD 1635 1636 1637 1640 1650 Z2 report Clear All 1660 Non-sending Report Department Hourly Clerk 20 CAS ELECTRICS CO.,LTD CODE Menu CODE 1710 1720 1700 1730 Printer Hardware 1740 1750 Serial Number Format Addup Total 1760 Ticket Print 1810 1820 1830 1840 1800 CODE Sub Menu І 1850 User / Security Configuration 1860 Test 1870 Scale Parameter 1880 Function Key Define CODE 1731 1732 1733 1734 1735 1736 1737 1738 Clear Mamory Scale Type Print Mode Label / Ticket size Sensor Calibration Sensor & motor Print Intensity Adjust Feed Length 1761 1762 1763 Select Ticket Item Select List Item Select Ticket Font Size 1851 1852 1853 1854 1855 1856 1861 1862 1863 1864 1865 1866 1867 1868 1871 1872 1873 1874 1875 New / Edit User Change Password List User Delete User Config Permission Clerk Key Display A/D Keyboard Chess Print Printer Sensor Memory Information Firmware Version Communication Display Printing Sale setup Clerk Logout System Restore Sub Menu І CODE 1911 1910 1900 Sub Menu Ⅱ Sale Mode Operation Mode Department & Store ID Data / Time Scale config Menu CODE Print Label Item Markdown Network Setting Communication 1920 Application 1930 Scale Lock/Unlock 1912 1913 1914 1915 1916 1917 Sub Menu Ⅱ Service Type DHCP IP Remote IP RS232C WLAN Setting WLAN Config 21 CAS ELECTRICS CO.,LTD 1940 1950 Check Scale 1960 Slave Scale Backup to scale 1961 1962 1963 New / Edit slave scale List slave scale Delete slave scale 3.3.3 Calibration Menu Tree CODE 8100 Menu Calibration CODE 8110 8120 8130 8140 8150 8160 8170 8180 8200 System Option 8300 Printer Hardware 8400 Network Option 8500 8600 Self Test Sub Menu І CODE Sub Menu Ⅱ Span Calibration Span / Zero Fine Adjust Capacity & Unit Gravity Constant Percent Calibration Linearity Calibration Zero & Tare Setting Factory Setting 8210 8220 8310 8320 8330 8340 8350 8360 8370 8380 8410 Clear Mamory Scale Type Print Mode Label / Ticket size Sensor Calibration Sensor & motor Print Intensity Adjust Feed Length Label Pre-print Printer Initialize Enable Interface 8510 DISPLAY Test 8520 A/D Test 8530 Keyboard Test 8540 Chess Print 8550 Printer Sensor Test 8560 Memory Information 8570 Firmware Version 8580 Cash Drawer Test 8590 Communication Test 8183 8184 8185 8186 8187 A/D Inutialize Linearity Fine Adjust Hysteresis Calibration Creep Setting A/D Firmware Parameter Setting 22 CAS ELECTRICS CO.,LTD 4. Calibration Mode 4.1 Calibration (Calibration MENU -> 1. Calibration) Execute Weight Calibration and A/D related settings (Access Authorized CAS Tester only) Open the tray and remove the calibration sealing. Order to access calibration mode: Insert a stick into the CAL switch. Switch power on, while pushing the CAL button. 23 CAS ELECTRICS CO.,LTD First page of Calibration mode 24 CAS ELECTRICS CO.,LTD 4.1.1 Span Calibration (Menu Code 8110) (Calibration MENU -> 1. Calibration -> 1. Span Calibration) * Requires set of certified weights. (For best result prepare 15kg/6kg(max) weights) Display shows the amount of weight that you will need. Caution: Span calibration must take place after “Capacity & Units” setting. ① Select “Span Calibration” ② Empty tray and press [ENTER] While calibrating zero display shows “Wait4” ~ “Wait0” and follow next message for Span Calibration. ③ Put on the Weight for Max. Capacities then press [ENTER] 25 CAS ELECTRICS CO.,LTD *Menu 8130 sets the max capacity for calibration. ④ Display shows “Wait4” ~ “Wait0” then following message. Error Message * When tray is unstable during calibration process, following message appear. 26 CAS ELECTRICS CO.,LTD * When calibration weight was too heavy or light, following message will appear. * When A/D failure is detected during Calibration following message will appear. Please check the connector between main board and other controller. 27 CAS ELECTRICS CO.,LTD 4.1.2 Span/Zero Fine Adjust (Menu Code 8120) (Calibration MENU -> 1. Calibration -> 2. Span/Zero Fine Adjust) This mode is for fine tuning of scale after span Cal. Please put Max weight on the tray and adjust A/D results at 60000, using the cursor key [◀ ▶.] and [Enter] key. ① Select menu “Span/Zero Fine Adjust” ⓐ ⓓ ⓑ ⓒ ⓐ Menu Code ⓑ Internal value ⓒ External value (weight) ⓓ Pure setting value of zero & Span * If ⓒ is not set to zero press [ZERO] key. Value ⓓ will update. ② Put Max. Capacity weight on the tray ③ Use [◀] [▶] key for fine adjust. * Insert setting value by cursor key (for the fine tune) [▶] Increases Span value “ⓓ” to decrease Internal value “ⓑ” [◀] Decreases Span value “ⓓ” to increase Internal value “ⓑ” Ex) Internal value 60014 needs to change 60000 Press [▶] X 14 Times to decrease internal value. 28 CAS ELECTRICS CO.,LTD * You can make the Internal value number as 60,000 automatically by pressing [TEST] key. Span value ⓓ will be updated automatically. 29 CAS ELECTRICS CO.,LTD 4.1.3 Capacity & Units (Menu Code 8130) (Calibration MENU -> 1. Calibration -> 3. Capacity & Units) You can move page, using [PAGE UP] [PAGE DOWN] key. Set scale’s Weighing unit, capacity, Interval, Cal Unit. Caution : Span calibration must take place after “Capacity & Units” setting. Do not change setting after Span calibration. No Option Setting Value Setting Scale Unit 1 Weighing Unit 0 : kg 1 : lb 2:g Setting Scale Max Capacity 2 Capacity 0 : 6 kg / 15 lb 5 : 300kg / 600 lb 1 : 15 kg / 30 lb 6 : 600kg / 1500 lb 2 : 30 kg / 60 lb 7 : 1500kg / 3000 lb 3 : 60kg / 150 lb 8 : 3000kg / 6000 lb 4 : 150kg / 300 lb 9 : 6000kg / 15000 lb Setting Usage of Multi-interval 3 Interval 0 : Single Interval 1 : Dual Interval Setting Calibration Weighing unit 0 : kg 4 Cal Unit 1 : lb * This setting uses in Span Calibration, Percent Calibration, Linearity Adjust. 30 CAS ELECTRICS CO.,LTD 4.1.4 Gravity Constant (Menu Code 8140) (Calibration MENU -> 1. Calibration -> 4. Gravity Constant) - CL7200 scale enables to calibrate in any country. You can set according to country standard gravity constant data. For case of full recalibration set the factory gravity first and then local area gravity code. (For span calibration Local gravity value is automatically matches with Factory gravity value) * Use the following table to determine the proper G-Constant for your area. 국 가 City G-Constant Country City G-Constant Argentina Buenos Aires 9.7979 Mexico Mexico City 9.7799 Australia Sydney 9.7979 Morocco Rabat 9.7964 Austria Vienna 9.8099 Netherlands Amsterdam 9.8129 Belgium Brussels 9.8114 New Zealand Wellington 9.8039 Belize Manamah 9.7904 Norway Oslo 9.8189 Bolivia La Paz 9.7844 Panama Panama City 9.7814 Brazil Brasilia 9.7889 Peru Lima 9.7829 Canada Montreal 9.8069 Philippines Manila 9.7844 Ottawa 9.8069 Poland Swider 9.8159 Toronto 9.8054 Portugal Lisbon 9.8009 Vancouver 9.8099 Rumania Bucharest 9.8054 Check Republic Prague 9.8114 Saudi Arabia Riyad 9.7904 Chile Santiago 9.7979 Scotland Stockholm 9.8189 China Hong Kong 9.8099 Singapore Singapore 9.7814 Colombia Bogota 9.7799 South Africa Johannesburg 9.7919 Costa Rica San Jose 9.7829 Spain Madrid 9.8024 Cypress Nicosia 9.7979 Switzerland Bern 9.8084 Denmark Copenhagen 9.8159 Taiwan Taipei 9.7904 Ecuador Quito 9.7724 Tunisia Tunis 9.7799 Finland Helsinki 9.8189 Turley Ankara 9.8024 Germany Dusseldorf 9.8129 Uruguay Montevideo 9.7964 Great Britain London 9.8144 USA Anchorage 9.8189 Greece Athens 9.8009 Atlanta 9.7964 Guatemala Guatemala 9.7844 Boston 9.8039 Hungary Budapest 9.8069 Chicago 9.8024 31 CAS ELECTRICS CO.,LTD Indonesia Djakarta 9.7814 Dallas 9.7949 Iraq Baghdad 9.7964 Detroit 9.8039 Japan Mishima 9.7979 Los Angeles 9.7979 Korea Seoul 9.7994 New York 9.8024 Kuwait Kuwait 9.7919 Philadelphia 9.8024 Lebanon Beirut 9.7964 San Francisco 9.7994 Mauritius Port Louis 9.7859 Caracas 9.7829 Venezuela NOTE: The G-Constant is the acceleration of gravity m/s 2 32 CAS ELECTRICS CO.,LTD 4.1.5 Percent Calibration (Menu Code 8150) (Calibration MENU -> 1. Calibration -> 5. Percent Calibration) When the case you don’t have max weight for calibration. Percent Calibration enables to use lighter weight. ① For 5kg weight, input [5]key and press [ENTER] ② Clear the tray and press [ENTER], then “Wait4~Wait0” will display. ③ Put 5kg on the tray the press [ENTER] after “Wait4~Wait0” exit menu. 33 CAS ELECTRICS CO.,LTD 4.1.6 Linearity Adjust (Menu Code 8160) (Calibration MENU -> 1. Calibration -> 6. Linearity Adjust) You can re-adjust the mid-range weight level for precise calibration. ① For 5kg weight, input [5]key and press [ENTER] ② Clear the tray and press [ENTER], then “Wait4~Wait0” will display ③ Put 5kg on the tray the press [ENTER] after “Wait4~Wait0”. ④ Put 15kg on the tray the press [ENTER] after “Wait4~Wait0” exit menu. 34 CAS ELECTRICS CO.,LTD 4.1.7 Zero & Tare Setting (Menu Code 8170) (Calibration MENU -> 1. Calibration -> 7. Zero & Tare Setting) CAUTION: This Setting is part of (OIML, NTEP, etc) regulation must be setting by the local restriction. ① Init-Zero range (%) Before Sales mode you need to compare Calibrated A/D value and current A/D value need to be in the safe range order to function property. Scale will not function if there is a weight or any distortion on the tray. ② Re-zero Range (%) During the usage, zero range might be unstable cause by tray and other condition. You can set the allowance percent (%) range for zero display. (OIML regulation restricts 4% of maximum weight range can be used) ③ Overload Range(d) You can set the maximum overload range. For example, [9] set as 15.045g (5gx[9]=45g). If the weight is over 15.045 overload message will appear. ④ Accumulation(Y/N) You can set Tare weights additively. This is useful additional package is used for different goods. ⑤ Subtraction(Y/N) You can set Tare only if the other tare weight is less then the first value. ⑥ Gross Zero Mark(Y/N) You can see zero state when total weight on the tray is 0. NOTE: * Gross weight is display will display total weight. (Tare setting does not effect) * Net weight is remain value of Tare weight. * If Tare setting is set as “N” the gross weight and net weight value is same. 35 CAS ELECTRICS CO.,LTD ⑦ Net Zero Mark(Y/N) When Tare weight is set to zero, Zero mark will display. In other words Net Weight is zero. ⑧ Gross Zero-Tracking(Y/N) Zero-tracking is possible during Gross Weight is 0. Factory setting is “Y”. ⑨ Net Zero-Tracking(Y/N) Zero-tracking is possible during Net Weight is 0. Factory setting is “N”. 36 CAS ELECTRICS CO.,LTD 4.1.8 Factory Setting (Menu Code 8180) (Calibration MENU -> 1. Calibration -> 8. Factory Setting) This setting A/D’s advanced setting only for factory primary setting. 37 CAS ELECTRICS CO.,LTD 4.1.8.1 A/D Initialize (Menu Code 8183) (Calibration MENU -> 1. Calibration -> 8. Factory Setting -> 3. A/D Initialize) CAUTION: Must record setting values before Selecting [Y]. This will set the scale first default setting 4.1.8.2 Linearity Fine Adjust (Menu Code 8184) (Calibration MENU -> 1. Calibration -> 8. Factory Setting -> 4. Linearity Fine Adjust) ① Selecting“LinearityFineAdjust” ⓐ ⓑ ⓓ ⓒ ⓐ Menu Code ⓑ Internal value ⓒ External value (weight) ⓓ Real value of Zero & Span NOTE: You can set 0 by pushing [ZERO]. This will update new Zero value. ② Put 5kg(Mid) on the tray. ③ Using cursor key for fine adjust. * How to use cursor key [▶] Increase Span value(ⓓ) to reduce internal (ⓑ)value [◀] Decrease Span value(ⓓ) to increase internal (ⓑ)value - Setting Mid value press [▼]key - Internal value 20005 to change 20000 press [▶] 5times. * Insert setting value by number key pad 38 CAS ELECTRICS CO.,LTD - Set Mid value: use curser key to highlight Mid value. - Type estimate value using number key then press “TEST” key for results - This process may take several times to set 20000. (During this process Mid weight is needed for best result.) Ex) Input “37371” by keypad and press “TEST” key ④ Put 15kg(Max) on the tray and change Span value. ⑤ Press [SAVE] to save and exit. 39 CAS ELECTRICS CO.,LTD 4.1.8.3 Hysteresys Calibration (Menu Code 8185) (Calibration MENU -> 1. Calibration -> 8. Factory Setting -> 5. Hysteresys Calibration) ① Selecting “Hysteresys Calibration” ② For 5kg Mid-weight, input [5]key and press [ENTER] ③ Empty tray and press [ENTER] ④ While calibrating zero display shows “Wait4” ~ “Wait0” and follow next message for Mid Calibration. ⑤ Put on the Weight for Mid-weight then press [ENTER] ⑥ While calibrating Mid-weight display shows “Wait4” ~ “Wait0” and follow next message for Span Calibration. 40 CAS ELECTRICS CO.,LTD ⑦ Put on the Weight for Max. Capacities then press [ENTER] *Menu 8130 sets the max capacity for calibration. ⑧ While calibrating span display shows “Wait4” ~ “Wait0” and follow next message for Mid Calibration. ⑨ Put on the Weight for Mid-weight. Capacities then press [ENTER] ⑩ While calibrating Mid-weight display shows “Wait4” ~ “Wait0” and exit 41 CAS ELECTRICS CO.,LTD 4.1.8.4 Creep Setting (Menu Code 8186) (Calibration MENU -> 1. Calibration -> 8. Factory Setting -> 6. Creep Setting) - Choose ‘N’ or ‘Y’ to determine the Creep Compensation - At Span Fine Adjust, enter the Changed internal value after increasing max weight for 30minute. - Creep Direction 1: (+) , 0: (-) 4.1.8.5 A/D Firmware (Menu Code 8187) (Calibration MENU -> 1. Calibration -> 8. Factory Setting -> 7. A/D Firmware) - It shows Firmware version of A/D module. 42 CAS ELECTRICS CO.,LTD 4.2 System Option 4.2.1 Clear Memory (Menu Code 8210) 4.2.1.1 Clear Report (Menu Code 8211) (Calibration MENU -> 2. System Options -> 1. Clear Memory) You can clear memory depends on options below. 4.2.1.2 Clear All PLU (Menu Code 8212) (Calibration Menu -> 2. System Option -> 1. Clear Momory -> 2. Clear All PLU) - Clear all PLU data. This time discount data is will be cleared. 43 CAS ELECTRICS CO.,LTD 4.2.1.3 Clear All Table (Menu Code 8213) (Calibration Menu -> 2. System Option -> 1. Clear Momory -> 3. Clear All Table) - Clear all Table date(Except PLU/discount data). 4.2.1.4 Report, PLU, Table 삭제 (Menu Code 8213) (Calibration Menu -> 2. System Option -> 1. Clear Momory -> 4. Clear Report,PLU,Table) - Clear Report, PLU, Table data 4.2.1.5 Flash All Clear (Menu Code 8214) (Calibration Menu -> 2. System Option -> 1. Clear Momory -> 5. Flash All Clear) NOTE: After clearing all the memory. You must install primary data. Except the program data all the item and font data will clear at once. 44 CAS ELECTRICS CO.,LTD 4.2.2 Scale Type (Menu Code 8220) (Calibration MENU -> 2. System Options -> 2. Scale Type) Select model : Basic type (CL7200-B), pole type, (CL7200- P) CAUTION: Selecting wrong model code will effect on key function. -1 : Standard type(CL7200-B) -2 : Pole type(CL7200-P) -3 : Hanging type -4 : Self-Service -5 : Double-B type 45 CAS ELECTRICS CO.,LTD 4.3 Printer Hardware No. Sub-menus Description 1 Print Mode Select label, ticket, continuous label mode. 2 Label / Ticket Lable mode: “Width(60)”, “Height(40)” and “Gap length(2)” Size Ticket mode: “Width(60)”, “Feed(20)” and “End Margin(5)” Continous Label: “Width(60)”, “Feed(40)” and “End Margin(2)” * ( ) are default value. 3 Sensor Enter the “Gap(128)” and “Peel(128)” values for printing sensor calibration. Calibration * The values in ( ) are default. * If you press “TEST” key, Gap and Peel values are adjusted automatically. * In case of Ticket mode, Gap value is not saved. 4 Sensor & Motor Setting Peel-off sensor, Rewind Motor, Label Paper type. 5 Print Intensity Set the extent of intensity of label (ticket) printed. 6 Adjust Feed Set adjusting values of feed length. Length This value can be from -200 to +200. You can change sign(+,-) by pressing ZERO key. + value will print higher than THP. * Pressing “TEST” key automatically feeds to adjust the feed length. 7 Label Pre-print You can set preprint length. 8 Printer Initialize You can reset printer. 4.3.1 Print Mode (Menu Code 8310) (Calibration MENU -> 3. Printer Hardware -> 1. Print Mode) - You can select [0] for Label mode, [1] for Ticket mode or [2] for Continuous Label mode. - Press [ENTER] to save current selection. 4.3.2 Label/Ticket Size (Menu Code 8320) (Calibration MENU -> 3. Printer Hardware -> 2. Label/Ticket Size) - You can input “Width,” “Height,” “Gap Length” of label manually. - Case of label mode press “TEST” key will automatically measures current label. - In Continuous Label Mode, [TEST] key will not operate and “End Margin” will be shown instead of “Gap Length”. - In Ticket Mode, “Width”,”Feed”,”End Margin”will be shown and [TEST] will not operate. 46 CAS ELECTRICS CO.,LTD 4.3.3 Sensor Calibration (Menu Code 8330) (Calibration MENU -> 3. Printer Hardware -> 3. Sensor Calibration) - You can input “Gap,” “Peel,” manually. - Pressing [TEST] key will operate “Auto Calibration” - For Ticket mode display will be same except “Gap” value. (“Gap” value will not save) 47
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement