1. Proper Operation
1.1 Introduction
Thank you for purchasing the CAS CL7200 series price computing printer scale. We have designed
this equipment with advanced features, high quality construction, and user-friendly menu driven
programming. We are confident that you will find the CAS CL7200 series scale will meet all of your most
demanding needs.
Sales data is easily acquired through many of the available reports which are quickly accessible through
the on-screen menus. Also available: High speed printer (4 inch per second), 53 preset keys (106 using
the SHIFT key or double click) per department, and several operation modes that enable you to control &
access to the scale.
For larger operations, CL7200 series has in-store network that can link-up to 32 scales. RS-232 port,
ethernet port, and wireless connection enable to export and import program data for time-save
mangement. On-time operation possible because of PLU and all other data files are kept locally in each
scale’s memory bank; the scale’s speed is the same as a stand-alone unit in a network.
The CL7200 series can use with both ticket and label. Auto measuring system enhances use any types
of roll paper. (Just entering a label’s length and width dimensions, you can use practically any roll)
Also
cartridge loading mechanism helps to refill the label roll easyly. Also you can print logos, templates, NutriFacts panels, ingredient messages, advertisement lines, and more to promots your store.
Remember, for proper installation and maintenance please read the CL7200 series Manual before use.
A wide variety of supplies, accessories, and expansion options are available through CAS Corporation for
whatever your new and increasing demands may require
The CL7200 series also comes with the SP-2 software package. This software runs on any PC using
the 95/98/2000/XP Windows OS. You can design your own label formats on your computer screen and
save them to your hard drive. With this percise interface, the labels you see on-screen appear exactly
on the printer.
You can also manage all of the CL7200’s programs and options like pricing, PLU
programming, etc. You can upload data from a CL300 series or download data. This is ideal solution for
an emergency scale backup system. All this and many more features are packed into the SP-2 software
package. SP-2 software package enhances your business next level.
2
CAS ELECTRICS CO.,LTD
1.2
Model and Specificationl
Model
CL7200 Series
Capacity
15Kg
30Kg
Interval
2g/5g
5g/10g
Max Tare
-5.998Kg
-9.995Kg
U-Type
S-Type
Display
Fornt : 10.2”TFT LCD (800x480)
Rear : 7”
15” TFT LCD (1024x768)
TFT LCD (800x480)
Zero Pass Range
1~50% (default 10%)
Re-Zero Range
1~50% (default 2%)
Overload Range
Max Capa. ~ Max Capa. + 255d (default Max+9d)
A/D Conversion Rate
Measurement type
Platter type
Key
Approx. 8/sec
Load cell
SUS
PLU Key : 72
Speed Key
Printing Resolution
Label Size
Barcode Type
S-Type
PLU Key : 144
Function Key: 36
PLU Key : 144
PLU
1~99999
3000
Ingredient 510 Char
1~999
999
user defined Barcode Format
1~99
99
Department
1~99
99
Tax Type
1~9
9
Group
1~99
99
Clerk
1~99
99
Discount
-
Origin
1~499
499
Data Table
Report
PLU Key : 72,
Function Key: 36
U-Type
99
Traceability
1~99
99
Slaughter House
1~99
99
Cutting Hall
1~99
99
Traceability Country
1~99
99
Label Format
Default :45, User:20
Bitmap
14
14
Customer
1~99
99
Quantity Symbol
1~8
8
Scroll Message
1~9
9
Pay Type
0~8
8
Sales Message
1~99
99
Nutrifact
1~500
500
Tare Table
1~99
99
Currency
1~4
4
X1/X2, Z1/Z2, Scale, PLU, Misc. PLU, Group, Department, Hourly, Clerk Report
202 dpi
Width: 40mm ~ 60mm,
Length: 20mm ~ 200mm
EAN13, EAN13A5, EAN8, I2OF5, UPCA, UPC13, CODE39, CODE93, CODE128, CODABAR,
Offer varoius sizes of label format, e.g Small, Middle, Large Size, and on the label format, also offers
Font
varioous types of fonts, such as Italic,Bold,Underline,Throgh Line, Double through line, Reverse,shadow,
outline etc.
Printer Type
Dimensions
Direct Thermal Print
U-Type
409 x 500 x 370 mm
P-Type
409 x 486 x 545 mm
U,S TYPE Tray : 380 x 250 mm
3
CAS ELECTRICS CO.,LTD
1.3 Environmental Conditions & Safety
1) Please avoid the following hostile conditions

Temperatures below or exceeding:

Ungrounded electrical outlet

Unstable or flimsy surface

Shared electrical outlet
-10° C ~ 40° C (14° F ~ 104° F)

Excessive vibration
 Wind or fans functioning in direct
contact with weighing platform.

Direct sunlight

Dust or dirt

High humidity

Poor ventilation
2) Environmental Protection
The scale should be installed in a dry and liquid free environment. When the scale is installed in a
high humidity or wet-type environment, be sure to avoid spilling or spraying directly on any surface
of the scale.
3) Personal Safety
It is very important to be aware of personal safety whenever maintaining or operating this equipment.
We have tried to place warning labels and other indicators at the actual location on the equipment
where the danger is most likely to occur. Warnings and cautions that are necessary for the safe
operation of the scale are contained in this manual. Please, make sure to read carefully ALL
warnings and cautions before operating the scale.
4) Observe the following safety precautions

Shut the scale OFF and unplug the scale whenever you are changing the label roll or whenever
working in the printer bay.

The outlet that the scale is plugged into, should be properly grounded.

Whenever connecting or disconnecting ANY cables from the scale, be sure to hold the cables by
the end connector. Failure to do so may cause a short circuit.

Maintain a static-free work area.

The outlet used must have the proper voltage ratings.
4
CAS ELECTRICS CO.,LTD
1.4
Leveling and Footer Location
1) Location
This scale must be placed on a flat and stable surface. Please keep the scale away from the
direct path of oscillating fans, ventilation systems, or strong drafts as these air disturbances can be
picked-up by the scale’s very sensitive weighing platform and may cause incorrect weight
readings.
1.1) General Footer
Factory setting (Footer location is following picture)
1.2) Short Case Footer
Unscrow the footer and place in center hole for narrow place.
5
CAS ELECTRICS CO.,LTD
2) Leveling
If the scale is not properly leveled, please adjust the 4 adjustable legs at the bottom of the scale.
Turn the legs clockwise or counterclockwise so as to center the bubble of the leveling gauge inside
the indicated circle. Turning the adjustable legs counter-clockwise (viewed from top of scale) will
lower that part of the scale. Turning the adjustable legs clockwise (viewed from top of scale) will
raise that part of the scale. (See Fig.)
6
CAS ELECTRICS CO.,LTD
1.5
Power Outlet and Requirements
Power Source : AC 100~240V, 50/60Hz, 1.5A
Power consumption : Max 90W
CL7200 series’s outlet is on bottom of scale.
Power Outlet
Power Switch
The CL7200 series is designed to be used almost anywhere in the world! Like the many appliances of
today, the CL7200 series is designed with an automatically switching power supply.
This allows
operation when connected to an AC source from 100V to 240V at 50/60Hz with 5% tolerance.
NOTE: Please make sure that the power lines used for the CL7200 series are dedicated lines with
No high-noise devices (such as compressors, motors, etc) running on it.
Also, make sure that the wiring to the electrical socket is correct.
If you are uncertain as to the state of your work’ electrical lines,
please contact a certified electrician.)
Once you are sure as to the safety of the electrical line,
make sure to ONLY plug the scale into a 3- prong outlet. The third prong is a safety ground and an
electrician should properly wire this if it is not correct or if you are unsure. Failure to this CAN result in
electrical shock from use of this or any electronic scale.
3)
Do not use any 3-prong to 2-prong adapters or break-off the third prong from the CLP power cord.
The third prong is necessary and must be properly connected.
4)
If you have any problems or questions regarding this matter, make sure to contact the CAS Service
Department.
7
CAS ELECTRICS CO.,LTD
2. Classification
2.1
Scale Overview
CL7200 has 2 differrnt type Standard Type, Self Type.
■ Standard U-Type
■ Self-Type
8
CAS ELECTRICS CO.,LTD
2.2
Display and Key
There is LCD(Front:800x480, Rear: 800x480) display on CL7200. LCD display indicates program tare,
weight, unit price, total price. Underbar inicates stable, net, zero, auto, save, prepack, D/C, shift, data
transfer.
LCD display shows menu massages for program mode.
■ CL7200-U
- CL7200 Sale mode(Operator View)
- Rear
9
CAS ELECTRICS CO.,LTD
■ CL7200-S
10
CAS ELECTRICS CO.,LTD
■ Indicators
B, P, R, H - TYPE
SYMBOLS
G - TYPE
DESCRIPTION
D - TYPE
ST
ST
STABLE
Stable weight indicator
▶0◀
ZR
▶0◀
Zero weight indicator
NET
AUTO
SAVE
PREPACK
D/C
SHIFT
TR
NET
AT
SV
PRK
DC
SH
TR
NET
AUTO
SAVE
PREPACK
D/C
SH
M
Net weight indicator
Print Mode indicator
Auto clearing status indicator
Auto clearing status and Print mode indicator
Discount status indicator
Speed key shift status indicator
Data transmission status indicator
Master status indicator
S
Slave status indicator
LN
Ethernet Connection Status
11
CAS ELECTRICS CO.,LTD
2.3 Printer
•Cartridge type print mechanism
•High quality ROHM printer
head (50km/5x107pulses)
•Improved a rotating force by
using 2 independent motors
•Large compartment for 120mm
paper roll
•High speed at 100 mm/sec.
•5 speed ranges for paper roll
quality adjustment
•Supports Paper
•Labels,
•Continuous strip labels,
•Lineless paper
12
CAS ELECTRICS CO.,LTD
2.4
Commuication
■ Standard
① RS232
② Cash Drawer
③ Ethernet
④ USB Device
⑤ USB Host x 2
■ Options
⑥ Wireless Ethernet Module
⑥ Wireless Ethernet Module
⑤ USB Host x 2
④ USB Device
① RS232
③ Ethernet
②Cash Drawer
13
CAS ELECTRICS CO.,LTD
3. Getting Started
3.1 Sealing Method
■ Method 1
■ Method 2
■ Method 3
■ Method 4
14
CAS ELECTRICS CO.,LTD
3.2 Installation of the Label Roll
■ Label Specifications
Outer diameter of roll : 100mm
Inner diameter of roll : 40mm
Width of receipt roll : 40, 50, 60mm
Width of label roll : 60mm(MAX)
■ Print Area
Width of label : 60mm(MAX)
Length of label : 120mm(MAX)
To install the label roll at ANY time you must follow the directions in this section:
1) Press the ON/OFF key and make sure that the display is completely off. Open the printer’s sideaccess panel. (See fig.1)
2) Lift up TPH lever as fig 2.
15
CAS ELECTRICS CO.,LTD
3) Remove cartridge as fig. 3.
4) Remove Pick-Up Spool assembley and paper guide from the cartridge as fig. 4.
4
5) Place the label in the scale as fig. 5
5
6) Press the FEED key.
NOTE: For auto label calibration press FEED key two or three times
* If label position is not correct, you have to check the followings:
a. Label size (Label setting menu)
b. Feed Adjustment (Feed adjustment menu)
c. Senseor calibration (Sensor Calibration menu)
16
CAS ELECTRICS CO.,LTD
3.3 Program Menu and Tree
3.3.1 How to access PROGRAM MODE
You can see the Program Menu screen by pressing the MENU key.
- Lower end of left number represents the Page number of Main Menu and Lower end of right number
represents the Page number of Sub Menu.
- Left number, based on “/”, means Present Page and Right means the number of total pages. You can
enter the page where you want by pressing the arrow keys.
17
CAS ELECTRICS CO.,LTD
3.3.2 Program Menu Tree
CODE
Menu
CODE
1110
1120
Sub Menu І
CODE
Sub Menu Ⅱ
Change Price
New/Edit
1130
Discount
1131
New/Edit
1132
1133
List
Delete
1137
1138
1139
1100
1150
1160
1170
1300
Copy
1142
Delete
PLU
1140
1200
1141
PLU data table
Ⅰ
PLU data table
Ⅱ
1147
1148
1149
Management
1143
Move
1144
Inhibit
1145
PLU Sale Count
Delete by PLU(DC)
Delete by Dept(DC)
Delete All
Delete by PLU No.
Delete by Dept. No.
Delete All
List
Speed Key
1161
1162
Edit Speed Key
Reset all setting
1211
1212
1213
1221
1222
1223
1241
1242
1243
1251
1252
1253
1261
1262
1263
1271
1272
1273
1274
1281
1282
1283
1311
1312
1313
1321
1322
1323
1331
1332
1333
New/Edit department
List department
Delete department
New / Edit group
List group
Delete group
New / Edit Sales Message
List Sales Message
Delete Sales Message
New / Edit origin
List origin
Delete origin
New / Edit barcode
List barcode
Delete barcode
New / Edit tare
List tare
Delete tare
Tare key
New / Edit Unit Symbol
List Unit Symbol
Delete Unit Symbol
New / Edit Ingredient
List Ingredient
Delete Ingredient
New / Edit Nutrifact
List Nutrifact
Delete Nutrifact
New / Edit traceability
List traceability
Delete traceability
Sample Printing
1210
Department
1220
Group
1240
Sales Message
1250
Origin
1260
Barcode
1270
Tare
1280
Unit Symbol
1310
Ingredient
1320
Nutrition facts
1330
Traceability
18
CAS ELECTRICS CO.,LTD
CODE
1300
1400
1500
1600
Menu
PLU data table
Ⅱ
Store data table
Global setting
CODE
Sub Menu І
1340
Country
1350
Slaughter House
1360
Cutting Hall
1410
Store
1420
Customer
1430
Scroll Message
1440
Currency
1450
Job Batch Schedule
1460
Scanner
1470
1510
1520
Label Format Key Table
Label Format
Barcode
1530
Discount
1540
Tax
1610
X1 report
Report
1620
1630
CODE
1341
1342
1343
1351
1352
1353
1361
1362
1363
1411
1412
1413
1431
1432
1433
1441
1442
1443
1451
1452
1453
1461
1462
1463
1464
1531
1532
1533
1534
1541
1542
1611
1612
1613
1614
1615
1616
1617
Sub Menu Ⅱ
New / Edit country
List country
Delete country
New / Edit slaughter house
List slaughter house
Delete slaughter house
New / Edit cutting hall
List cutting hall
Delete cutting hall
New / Edit Store
List Store
Delete Store
New / Edit Customer
List Customer
Delete Customer
Configuration
Edit Scroll Message
List Scroll Message
New / Edit Currency
List Currency
Delete Currency
New / Edit Schedule
List Schedule
Delete Schedule
New / Edit Conv Table
List Conv Table
Delete Conv Table
Scanner Config
Priority setting
Weight discount
Count discount
PCS discount
Set Global Tax
Global Tax No.
Scale
PLU
Misc. PLU
Group
Department
Hourly
Clerk
Z1 report
X2 report
1631
1632
1633
1634
Scale
PLU
Misc. PLU
Group
19
CAS ELECTRICS CO.,LTD
1635
1636
1637
1640
1650
Z2 report
Clear All
1660
Non-sending Report
Department
Hourly
Clerk
20
CAS ELECTRICS CO.,LTD
CODE
Menu
CODE
1710
1720
1700
1730
Printer Hardware
1740
1750
Serial Number Format
Addup Total
1760
Ticket
Print
1810
1820
1830
1840
1800
CODE
Sub Menu І
1850
User / Security
Configuration
1860
Test
1870
Scale Parameter
1880
Function Key Define
CODE
1731
1732
1733
1734
1735
1736
1737
1738
Clear Mamory
Scale Type
Print Mode
Label / Ticket size
Sensor Calibration
Sensor & motor
Print Intensity
Adjust Feed Length
1761
1762
1763
Select Ticket Item
Select List Item
Select Ticket Font Size
1851
1852
1853
1854
1855
1856
1861
1862
1863
1864
1865
1866
1867
1868
1871
1872
1873
1874
1875
New / Edit User
Change Password
List User
Delete User
Config Permission
Clerk Key
Display
A/D
Keyboard
Chess Print
Printer Sensor
Memory Information
Firmware Version
Communication
Display
Printing
Sale setup
Clerk Logout
System Restore
Sub Menu І
CODE
1911
1910
1900
Sub Menu Ⅱ
Sale Mode
Operation Mode
Department & Store ID
Data / Time
Scale config
Menu
CODE
Print Label Item
Markdown
Network Setting
Communication
1920
Application
1930
Scale Lock/Unlock
1912
1913
1914
1915
1916
1917
Sub Menu Ⅱ
Service Type
DHCP
IP
Remote IP
RS232C
WLAN Setting
WLAN Config
21
CAS ELECTRICS CO.,LTD
1940
1950
Check Scale
1960
Slave Scale
Backup to scale
1961
1962
1963
New / Edit slave scale
List slave scale
Delete slave scale
3.3.3 Calibration Menu Tree
CODE
8100
Menu
Calibration
CODE
8110
8120
8130
8140
8150
8160
8170
8180
8200
System Option
8300
Printer Hardware
8400
Network Option
8500
8600
Self Test
Sub Menu І
CODE
Sub Menu Ⅱ
Span Calibration
Span / Zero Fine Adjust
Capacity & Unit
Gravity Constant
Percent Calibration
Linearity Calibration
Zero & Tare Setting
Factory Setting
8210
8220
8310
8320
8330
8340
8350
8360
8370
8380
8410
Clear Mamory
Scale Type
Print Mode
Label / Ticket size
Sensor Calibration
Sensor & motor
Print Intensity
Adjust Feed Length
Label Pre-print
Printer Initialize
Enable Interface
8510
DISPLAY Test
8520
A/D Test
8530
Keyboard Test
8540
Chess Print
8550
Printer Sensor Test
8560
Memory Information
8570
Firmware Version
8580
Cash Drawer Test
8590
Communication Test
8183
8184
8185
8186
8187
A/D Inutialize
Linearity Fine Adjust
Hysteresis Calibration
Creep Setting
A/D Firmware
Parameter Setting
22
CAS ELECTRICS CO.,LTD
4. Calibration Mode
4.1
Calibration
(Calibration MENU -> 1. Calibration)
Execute Weight Calibration and A/D related settings
(Access Authorized CAS Tester only)
Open the tray and remove the calibration sealing.
Order to access calibration mode:
Insert a stick into the CAL switch. Switch power on, while pushing the CAL button.
23
CAS ELECTRICS CO.,LTD
First page of Calibration mode
24
CAS ELECTRICS CO.,LTD
4.1.1 Span Calibration (Menu Code 8110)
(Calibration MENU -> 1. Calibration -> 1. Span Calibration)
* Requires set of certified weights. (For best result prepare 15kg/6kg(max) weights)
Display shows the amount of weight that you will need.
Caution: Span calibration must take place after “Capacity & Units” setting.
① Select “Span Calibration”
② Empty tray and press [ENTER]
While calibrating zero display shows “Wait4” ~ “Wait0” and follow next message for Span Calibration.
③ Put on the Weight for Max. Capacities then press [ENTER]
25
CAS ELECTRICS CO.,LTD
*Menu 8130 sets the max capacity for calibration.
④ Display shows “Wait4” ~ “Wait0” then following message.
Error Message
* When tray is unstable during calibration process, following message appear.
26
CAS ELECTRICS CO.,LTD
* When calibration weight was too heavy or light, following message will appear.
* When A/D failure is detected during Calibration following message will appear.
Please check the connector between main board and other controller.
27
CAS ELECTRICS CO.,LTD
4.1.2 Span/Zero Fine Adjust (Menu Code 8120)
(Calibration MENU -> 1. Calibration -> 2. Span/Zero Fine Adjust)
This mode is for fine tuning of scale after span Cal. Please put Max weight on the tray and adjust A/D
results at 60000, using the cursor key [◀ ▶.] and [Enter] key.
① Select menu “Span/Zero Fine Adjust”
ⓐ
ⓓ
ⓑ
ⓒ
ⓐ Menu Code
ⓑ Internal value
ⓒ External value (weight)
ⓓ Pure setting value of zero & Span
* If ⓒ is not set to zero press [ZERO] key. Value ⓓ will update.
② Put Max. Capacity weight on the tray
③ Use [◀] [▶] key for fine adjust.
* Insert setting value by cursor key (for the fine tune)
[▶] Increases Span value “ⓓ” to decrease Internal value “ⓑ”
[◀] Decreases Span value “ⓓ” to increase Internal value “ⓑ”
Ex) Internal value 60014 needs to change 60000
Press [▶] X 14 Times to decrease internal value.
28
CAS ELECTRICS CO.,LTD
* You can make the Internal value number as 60,000 automatically by pressing [TEST] key. Span value ⓓ
will be updated automatically.
29
CAS ELECTRICS CO.,LTD
4.1.3 Capacity & Units (Menu Code 8130)
(Calibration MENU -> 1. Calibration -> 3. Capacity & Units)
You can move page, using [PAGE UP] [PAGE DOWN] key.
Set scale’s Weighing unit, capacity, Interval, Cal Unit.
Caution : Span calibration must take place after “Capacity & Units” setting.
Do not change setting after Span calibration.
No
Option
Setting Value
Setting Scale Unit
1
Weighing Unit
0 : kg
1 : lb
2:g
Setting Scale Max Capacity
2
Capacity
0 : 6 kg / 15 lb
5 : 300kg / 600 lb
1 : 15 kg / 30 lb
6 : 600kg / 1500 lb
2 : 30 kg / 60 lb
7 : 1500kg / 3000 lb
3 : 60kg / 150 lb
8 : 3000kg / 6000 lb
4 : 150kg / 300 lb
9 : 6000kg / 15000 lb
Setting Usage of Multi-interval
3
Interval
0 : Single Interval
1 : Dual Interval
Setting Calibration Weighing unit
0 : kg
4
Cal Unit
1 : lb
* This setting uses in Span Calibration,
Percent Calibration, Linearity Adjust.
30
CAS ELECTRICS CO.,LTD
4.1.4 Gravity Constant (Menu Code 8140)
(Calibration MENU -> 1. Calibration -> 4. Gravity Constant)
- CL7200 scale enables to calibrate in any country. You can set according to country standard gravity
constant data. For case of full recalibration set the factory gravity first and then local area gravity code.
(For span calibration Local gravity value is automatically matches with Factory gravity value)
* Use the following table to determine the proper G-Constant for your area.
국 가
City
G-Constant
Country
City
G-Constant
Argentina
Buenos Aires
9.7979
Mexico
Mexico City
9.7799
Australia
Sydney
9.7979
Morocco
Rabat
9.7964
Austria
Vienna
9.8099
Netherlands
Amsterdam
9.8129
Belgium
Brussels
9.8114
New Zealand
Wellington
9.8039
Belize
Manamah
9.7904
Norway
Oslo
9.8189
Bolivia
La Paz
9.7844
Panama
Panama City
9.7814
Brazil
Brasilia
9.7889
Peru
Lima
9.7829
Canada
Montreal
9.8069
Philippines
Manila
9.7844
Ottawa
9.8069
Poland
Swider
9.8159
Toronto
9.8054
Portugal
Lisbon
9.8009
Vancouver
9.8099
Rumania
Bucharest
9.8054
Check Republic
Prague
9.8114
Saudi Arabia
Riyad
9.7904
Chile
Santiago
9.7979
Scotland
Stockholm
9.8189
China
Hong Kong
9.8099
Singapore
Singapore
9.7814
Colombia
Bogota
9.7799
South Africa
Johannesburg
9.7919
Costa Rica
San Jose
9.7829
Spain
Madrid
9.8024
Cypress
Nicosia
9.7979
Switzerland
Bern
9.8084
Denmark
Copenhagen
9.8159
Taiwan
Taipei
9.7904
Ecuador
Quito
9.7724
Tunisia
Tunis
9.7799
Finland
Helsinki
9.8189
Turley
Ankara
9.8024
Germany
Dusseldorf
9.8129
Uruguay
Montevideo
9.7964
Great Britain
London
9.8144
USA
Anchorage
9.8189
Greece
Athens
9.8009
Atlanta
9.7964
Guatemala
Guatemala
9.7844
Boston
9.8039
Hungary
Budapest
9.8069
Chicago
9.8024
31
CAS ELECTRICS CO.,LTD
Indonesia
Djakarta
9.7814
Dallas
9.7949
Iraq
Baghdad
9.7964
Detroit
9.8039
Japan
Mishima
9.7979
Los Angeles
9.7979
Korea
Seoul
9.7994
New York
9.8024
Kuwait
Kuwait
9.7919
Philadelphia
9.8024
Lebanon
Beirut
9.7964
San Francisco
9.7994
Mauritius
Port Louis
9.7859
Caracas
9.7829
Venezuela
NOTE: The G-Constant is the acceleration of gravity m/s
2
32
CAS ELECTRICS CO.,LTD
4.1.5 Percent Calibration (Menu Code 8150)
(Calibration MENU -> 1. Calibration -> 5. Percent Calibration)
When the case you don’t have max weight for calibration. Percent Calibration enables to use lighter weight.
① For 5kg weight, input [5]key and press [ENTER]
② Clear the tray and press [ENTER], then “Wait4~Wait0” will display.
③ Put 5kg on the tray the press [ENTER] after “Wait4~Wait0” exit menu.
33
CAS ELECTRICS CO.,LTD
4.1.6 Linearity Adjust (Menu Code 8160)
(Calibration MENU -> 1. Calibration -> 6. Linearity Adjust)
You can re-adjust the mid-range weight level for precise calibration.
① For 5kg weight, input [5]key and press [ENTER]
② Clear the tray and press [ENTER], then “Wait4~Wait0” will display
③ Put 5kg on the tray the press [ENTER] after “Wait4~Wait0”.
④ Put 15kg on the tray the press [ENTER] after “Wait4~Wait0” exit menu.
34
CAS ELECTRICS CO.,LTD
4.1.7 Zero & Tare Setting (Menu Code 8170)
(Calibration MENU -> 1. Calibration -> 7. Zero & Tare Setting)
CAUTION: This Setting is part of (OIML, NTEP, etc) regulation must be setting by the local restriction.
① Init-Zero range (%)
Before Sales mode you need to compare Calibrated A/D value and current A/D value need to be in the safe
range order to function property. Scale will not function if there is a weight or any distortion on the tray.
② Re-zero Range (%)
During the usage, zero range might be unstable cause by tray and other condition. You can set the
allowance percent (%) range for zero display. (OIML regulation restricts 4% of maximum weight range can
be used)
③ Overload Range(d)
You can set the maximum overload range. For example, [9] set as 15.045g (5gx[9]=45g). If the weight is
over 15.045 overload message will appear.
④ Accumulation(Y/N)
You can set Tare weights additively. This is useful additional package is used for different goods.
⑤ Subtraction(Y/N)
You can set Tare only if the other tare weight is less then the first value.
⑥ Gross Zero Mark(Y/N)
You can see zero state when total weight on the tray is 0.
NOTE: * Gross weight is display will display total weight. (Tare setting does not effect)
* Net weight is remain value of Tare weight.
* If Tare setting is set as “N” the gross weight and net weight value is same.
35
CAS ELECTRICS CO.,LTD
⑦ Net Zero Mark(Y/N)
When Tare weight is set to zero, Zero mark will display. In other words Net Weight is zero.
⑧ Gross Zero-Tracking(Y/N)
Zero-tracking is possible during Gross Weight is 0. Factory setting is “Y”.
⑨ Net Zero-Tracking(Y/N)
Zero-tracking is possible during Net Weight is 0. Factory setting is “N”.
36
CAS ELECTRICS CO.,LTD
4.1.8 Factory Setting (Menu Code 8180)
(Calibration MENU -> 1. Calibration -> 8. Factory Setting)
This setting A/D’s advanced setting only for factory primary setting.
37
CAS ELECTRICS CO.,LTD
4.1.8.1 A/D Initialize (Menu Code 8183)
(Calibration MENU -> 1. Calibration -> 8. Factory Setting -> 3. A/D Initialize)
CAUTION: Must record setting values before Selecting [Y]. This will set the scale first default setting
4.1.8.2 Linearity Fine Adjust (Menu Code 8184)
(Calibration MENU -> 1. Calibration -> 8. Factory Setting -> 4. Linearity Fine Adjust)
① Selecting“LinearityFineAdjust”
ⓐ
ⓑ
ⓓ
ⓒ
ⓐ Menu Code
ⓑ Internal value
ⓒ External value (weight)
ⓓ Real value of Zero & Span
NOTE: You can set 0 by pushing [ZERO]. This will update new Zero value.
② Put 5kg(Mid) on the tray.
③ Using cursor key for fine adjust.
* How to use cursor key
[▶] Increase Span value(ⓓ) to reduce internal (ⓑ)value
[◀] Decrease Span value(ⓓ) to increase internal (ⓑ)value
- Setting Mid value press [▼]key
- Internal value 20005 to change 20000 press [▶] 5times.
* Insert setting value by number key pad
38
CAS ELECTRICS CO.,LTD
- Set Mid value: use curser key to highlight Mid value.
- Type estimate value using number key then press “TEST” key for results
- This process may take several times to set 20000.
(During this process Mid weight is needed for best result.)
Ex) Input “37371” by keypad and press “TEST” key
④ Put 15kg(Max) on the tray and change Span value.
⑤ Press [SAVE] to save and exit.
39
CAS ELECTRICS CO.,LTD
4.1.8.3
Hysteresys Calibration (Menu Code 8185)
(Calibration MENU -> 1. Calibration -> 8. Factory Setting -> 5. Hysteresys Calibration)
① Selecting “Hysteresys Calibration”
② For 5kg Mid-weight, input [5]key and press [ENTER]
③ Empty tray and press [ENTER]
④ While calibrating zero display shows “Wait4” ~ “Wait0” and follow next message for Mid Calibration.
⑤ Put on the Weight for Mid-weight then press [ENTER]
⑥ While calibrating Mid-weight display shows “Wait4” ~ “Wait0” and follow next message
for Span Calibration.
40
CAS ELECTRICS CO.,LTD
⑦ Put on the Weight for Max. Capacities then press [ENTER]
*Menu 8130 sets the max capacity for calibration.
⑧ While calibrating span display shows “Wait4” ~ “Wait0” and follow next message for Mid Calibration.
⑨ Put on the Weight for Mid-weight. Capacities then press [ENTER]
⑩ While calibrating Mid-weight display shows “Wait4” ~ “Wait0” and exit
41
CAS ELECTRICS CO.,LTD
4.1.8.4 Creep Setting (Menu Code 8186)
(Calibration MENU -> 1. Calibration -> 8. Factory Setting -> 6. Creep Setting)
- Choose ‘N’ or ‘Y’ to determine the Creep Compensation
- At Span Fine Adjust, enter the Changed internal value after increasing max weight for 30minute.
- Creep Direction 1: (+) , 0: (-)
4.1.8.5 A/D Firmware (Menu Code 8187)
(Calibration MENU -> 1. Calibration -> 8. Factory Setting -> 7. A/D Firmware)
- It shows Firmware version of A/D module.
42
CAS ELECTRICS CO.,LTD
4.2 System Option
4.2.1 Clear Memory (Menu Code 8210)
4.2.1.1 Clear Report (Menu Code 8211)
(Calibration MENU -> 2. System Options -> 1. Clear Memory)
You can clear memory depends on options below.
4.2.1.2 Clear All PLU (Menu Code 8212)
(Calibration Menu -> 2. System Option -> 1. Clear Momory -> 2. Clear All PLU)
- Clear all PLU data. This time discount data is will be cleared.
43
CAS ELECTRICS CO.,LTD
4.2.1.3 Clear All Table (Menu Code 8213)
(Calibration Menu -> 2. System Option -> 1. Clear Momory -> 3. Clear All Table)
- Clear all Table date(Except PLU/discount data).
4.2.1.4 Report, PLU, Table 삭제 (Menu Code 8213)
(Calibration Menu -> 2. System Option -> 1. Clear Momory -> 4. Clear Report,PLU,Table)
- Clear Report, PLU, Table data
4.2.1.5 Flash All Clear (Menu Code 8214)
(Calibration Menu -> 2. System Option -> 1. Clear Momory -> 5. Flash All Clear)
NOTE: After clearing all the memory. You must install primary data.
Except the program data all the item and font data will clear at once.
44
CAS ELECTRICS CO.,LTD
4.2.2 Scale Type (Menu Code 8220)
(Calibration MENU -> 2. System Options -> 2. Scale Type)
Select model : Basic type (CL7200-B), pole type, (CL7200- P)
CAUTION: Selecting wrong model code will effect on key function.
-1 : Standard type(CL7200-B)
-2 : Pole type(CL7200-P)
-3 : Hanging type
-4 : Self-Service
-5 : Double-B type
45
CAS ELECTRICS CO.,LTD
4.3 Printer Hardware
No.
Sub-menus
Description
1
Print Mode
Select label, ticket, continuous label mode.
2
Label / Ticket
Lable mode: “Width(60)”, “Height(40)” and “Gap length(2)”
Size
Ticket mode: “Width(60)”, “Feed(20)” and “End Margin(5)”
Continous Label: “Width(60)”, “Feed(40)” and “End Margin(2)”
* ( ) are default value.
3
Sensor
Enter the “Gap(128)” and “Peel(128)” values for printing sensor calibration.
Calibration
* The values in ( ) are default.
* If you press “TEST” key, Gap and Peel values are adjusted automatically.
* In case of Ticket mode, Gap value is not saved.
4
Sensor & Motor
Setting Peel-off sensor, Rewind Motor, Label Paper type.
5
Print Intensity
Set the extent of intensity of label (ticket) printed.
6
Adjust Feed
Set adjusting values of feed length.
Length
This value can be from -200 to +200. You can change sign(+,-) by pressing
ZERO key.
+ value will print higher than THP.
* Pressing “TEST” key automatically feeds to adjust the feed length.
7
Label Pre-print
You can set preprint length.
8
Printer Initialize
You can reset printer.
4.3.1 Print Mode (Menu Code 8310)
(Calibration MENU -> 3. Printer Hardware -> 1. Print Mode)
- You can select [0] for Label mode, [1] for Ticket mode or [2] for Continuous Label mode.
- Press [ENTER] to save current selection.
4.3.2 Label/Ticket Size (Menu Code 8320)
(Calibration MENU -> 3. Printer Hardware -> 2. Label/Ticket Size)
- You can input “Width,” “Height,” “Gap Length” of label manually.
- Case of label mode press “TEST” key will automatically measures current label.
- In Continuous Label Mode, [TEST] key will not operate and “End Margin” will be shown instead of “Gap
Length”.
- In Ticket Mode, “Width”,”Feed”,”End Margin”will be shown and [TEST] will not operate.
46
CAS ELECTRICS CO.,LTD
4.3.3 Sensor Calibration (Menu Code 8330)
(Calibration MENU -> 3. Printer Hardware -> 3. Sensor Calibration)
- You can input “Gap,” “Peel,” manually.
- Pressing [TEST] key will operate “Auto Calibration”
- For Ticket mode display will be same except “Gap” value. (“Gap” value will not save)