Catalog Page

Catalog Page
Nols Muller
DC drives
Upgrade Kits DCV700/DCS500/DCS600 
DCS800
© ABB Group
May 13, 2013 | Slide 1
DCS800-R Upgrade Kits
Upgrade solutions for DCS500 / DCS800 drives

Upgrade of DCS500 / DCS500B / DCS600 to DCS800

Available for modules



© ABB Group
May 13, 2013 | Slide 2
DCS500 / DCV700 (based on SDCS-CON-1)

680A … 5150A

Sizes: C2b, C3, C4
DCS500B / DCS600 (based on SDCS-CON-2)

900A … 5200A

Sizes: A5, A6, A7
Content of an Upgrade Kit (Standard)

Control board SDCS-CON-4 with SDCS-DSL-4

Electronics power supply board SDCS-POW-4

Measuring board SDCS-PIN-51 (only when needed)

DCS800 Control Panel

Cables

Mechanical parts for assembling
DCS800-R Upgrade Kits
Availability overview for DCS500/DCV700
DCS800-R Upgrade kits are only available for yellow highlighted converter types
© ABB Group
May 13, 2013 | Slide 3
DCS800-R Upgrade Kits
Availability overview for DCS500B/DCS600
DCS800-R Upgrade kits are only available for yellow highlighted converter types
© ABB Group
May 13, 2013 | Slide 4
DCS800-R Upgrade Kits
Requirements and Design conditions for Upgrades
Requirements
Design conditions

Converter modules DCS500, DCS500B
(except Unitrol), DCS600

Max. 24VDC control voltage for SDCSCON-4 instead of 48VDC

DC Voltage 400VAC up to 1000 VAC


Nominal current 680A up to 5200A
Upgrades DCS600 -> DCS800 require
SDCS-COM-8x board for fiber optic
connections

Sufficient physical condition of the
existing module

Old field exciters have to be exchanged
due to DCSLink Communication.

Line chokes can be reused if field settings
remain unchanged

I/O extension board SDCS-IOE-1 has to be
exchanged by RDIO-01 and RAIO-01

New commissioning tool DriveWindow 2.2
or higher is needed
© ABB Group
May 13, 2013 | Slide 5
DCS800-R Upgrade Kits
Supported and not supported parts
Supported parts

I/O board SDCS-IOB-2x

I/O board SDCS-IOB-3,

control panel CDP 312 xx via SDCS-COM81 or SDCS-COM-82 and

Nxxx fieldbus adapter used with DCS 500B
or DCS 600 via SDCS-COM-82
© ABB Group
May 13, 2013 | Slide 6
Not supported parts

all old field exciters for DCS 500, DCS 500B
and DCS 600,

DCS-IOE-1

control panels CDP 310 and CDP 311

Nxxx fieldbus adapter used with DCS 500

APC1 used for DCV 700

Reuse of APC2 requires modifications in the
control logic and additional hardware

All old tools like DDCTool, CMTTool,
DriveWindow 1.x and DriveWindow 2.1
DCS800-R Upgrade Kits
Conditions caused by the application

In case of an additional application three scenarios are possible



Application program located in the APC1 or APC2 of a DCV 700.

APC1: No interface available

APC2: Optical connection board YPQ112 is to add between APC2 and SDCS-COM81 and control logic is to modify

The application program is as function blocks in the DCS 500 or DCS 500B.  DriveAP
Programmimg or CoDeSys Programming

The application program is located in the AMC board of a DCS 600 see APPLIC NAME
(4.03)  CoDeSys Programming
Master-follower configurations

Master-follower via SDCS-COM-8 should be used for upgrading a DCS 600. The fiber
optic cable can be reused.

Master-follower via DCSLink should be used for upgrading a DCS 500 or DCS 500B.
Hard-Parallel configuration

Additional engineering is needed. Please contact your local ABB .
© ABB Group
May 13, 2013 | Slide 7
DCS800-R Upgrade Kits
Upgrade size A5 to D5
Article Codes
DCS800-R00-9305
DCS800-R00-9306 (with field exciter)
Included parts

SDCS-POW-4

FEX-425-Int (only DCS800-R00-9306)

electronic tray

SDCS-CON-4 with SDCS-DSL-4

covers

DCS800 Control Panel

SDCS-PIN-51

all boards are coated
Affected modules:
© ABB Group
May 13, 2013 | Slide 8
Converter type DCS 500B
Converter type DCS 600
DCS50xB0903-y1
DCS50xB1203-y1
DCS50xB1503-y1
DCS50xB2003-y1
DCS60x-0903-y1
DCS60x-1203-y1
DCS60x-1503-y1
DCS60x-2003-y1
DCS800-R Upgrade Kits
Upgrade size A6/A7 to D6/D7
Article Code
DCS800-R00-9405
Included parts

SDCS-POW-4

electronic tray

SDCS-CON-4 with SDCS-DSL-4

SDCS-PIN-51

covers

DCS800 Control Panel

all boards are coated
Affected modules:
© ABB Group
May 13, 2013 | Slide 9
Converter type DCS 500B
Converter type DCS 600
DCS50xB1903-y1
DCS50xB2053-y1
DCS50xB2503-y1
DCS50xB3003-y1
DCS50xB2053-y1
DCS50xB2603-y1
DCS50xB3203-y1
DCS50xB3303-y1
DCS50xB4003-y1
DCS50xB4803-y1
DCS50xB5203-y1
DCS60x-1903-y1
DCS60x-2053-y1
DCS60x-2503-y1
DCS60x-3003-y1
DCS60x-2053-y1
DCS60x-2603-y1
DCS60x-3203-y1
DCS60x-3303-y1
DCS60x-4003-y1
DCS60x-4803-y1
DCS50x-5203-y1
DCS800-R Upgrade Kits
Upgrade size C2b to D5
Article Code
DCS800-R00-9005
Included parts

SDCS-POW-4

electronic tray

SDCS-CON-4 with SDCS-DSL-4

covers

DCS800 Control Panel

all boards are coated
Affected modules:
© ABB Group
May 13, 2013 | Slide 10
Converter type DCS 500B
Converter type DCS 600
DCS50x-0680-y1
DCS50x-0820-y1
DCS50x-1000-y1
DCS60x-0680-y1
DCS60x-0820-y1
DCS60x-1000-y1
DCS800-R Upgrade Kits
Upgrade size C3 to D6
Article Code
DCS800-R00-9205
Included parts

SDCS-POW-4

electronic tray

SDCS-CON-4 with SDCS-DSL-4

SDCS-PIN-51

covers

DCS800 Control Panel

all boards are coated
Affected modules:
© ABB Group
May 13, 2013 | Slide 11
Converter type DCS 500B
Converter type DCS 600
DCS50xB0900-y1
DCS50xB1200-y1
DCS50xB1500-y1
DCS50xB2000-y1
DCS60x-0900-y1
DCS60x-1200-y1
DCS60x-1500-y1
DCS60x-2000-y1
DCS800-R Upgrade Kits
Upgrade size C4 to D7
Article Code
DCS800-R00-9105
Included parts

SDCS-POW-4

electronic tray

SDCS-CON-4 with SDCS-DSL-4

SDCS-PIN-51

covers

DCS800 Control Panel

all boards are coated
Affected modules:
© ABB Group
May 13, 2013 | Slide 12
Converter type DCS 500B
Converter type DCS 600
DCS50xB2050-y1
DCS50xB2500-y1
DCS50xB2650-y1
DCS50xB3200-y1
DCS50xB3300-y1
DCS50xB4000-y1
DCS50xB4750-y1
DCS50xB5150-y1
DCS60x-2050-y1
DCS60x-2500-y1
DCS60x-2650-y1
DCS60x-3200-y1
DCS60x-3300-y1
DCS60x-4000-y1
DCS60x-4750-y1
DCS50x-5150-y1
DCS800-R Upgrade Kits
Overview Parts Upgrade Kit
© ABB Group
May 13, 2013 | Slide 13
DCS800-R Upgrade Kits
DCV700 System Structure
For the communication
with overriding control
system additional
interface devices are to
implement.
See next slides
SDCS-POW-1 is to
be replaced by
SDCS-POW-4
For drive diagnostic
SDCS-COM-81 with
DriveWindow is to use
To be replaced by a new
field exciter like:
DCF503B, DCF803,
FEX4-Int
For Master-Follower
communication DCS-Link via
DCS-DSL-4 or DDCS via
SDCS-COM-81 are to use
SDCS-CON-1 board is to
replace by SDCS-CON-4
including SDCS-COM-81,
SDCS-DSL-4 and panel
© ABB Group
May 13, 2013 | Slide 14
In case of frame size C3
the existing SDCS-PIN51 is to be replaced by
a new SDCS-PIN-51
DCS800-R Upgrade Kits
How to connect existing control system to SDCS-CON-4 (1/3)
Extension of APC2 controller with a DDCS interface adapter.
New interface board YPQ112B to
install into the existing APC rack.
YPQ112B
DDCS
Interface
Fiber
optic
link
SDCS-COM-81
Not more in
use. Can be
removed.
SDCS-DSL-4
SDCS-CON-4
Please note:
Installation of the YPQ112B interface adapter requires small modifications in the APC control program.
Availability of the right software tools and programming skills for APC controller are to ensure.
© ABB Group
May 13, 2013 | Slide 15
DCS800-R Upgrade Kits
How to connect existing control system to SDCS-CON-4 (2/3)
Removal of APC2 and direct connection to the overriding system via AF100 (MB90)
= Advant Fieldbus (AF100)
CI810B
Interface
DDCS / Advant
Fieldbus
AF100 communication
interface kit NAFA-01
consisting of:
CI810 + TC505 +
TB810/TB811
TB810
Fiber
optic
link
SDCS-COM-81
SDCS-DSL-4
SDCS-CON-4
Not more in
use. Can be
removed.
Please note:
Installation of the CI810B communication interface requires small modifications in the overriding control
system e.g. AC450. Furthermore the removal of the APC controller requires adaption of the existing APC
software program either into the overriding system or into the drive via DriveAP or CoDeSys. Availability of
the right software tools and programming skills are to ensure.
© ABB Group
May 13, 2013 | Slide 16
DCS800-R Upgrade Kits
How to connect existing control system to SDCS-CON-4 (3/3)
Removal of APC2 and direct connection to the overriding system via MFB (MasterFieldbus)
PE1354B
= Master FieldBus
MFB-Modulebus
converter
New fieldbus converter
PE1345B for Master
Fieldbus is to install and
to connect.
Fiber
optic
link
SDCS-COM-81
SDCS-DSL-4
SDCS-CON-4
Not more in
use. Can be
removed.
Please note:
Installation of the PE1354B fieldbus converter requires small modifications in the overriding control system
e.g. MP200. Furthermore the removal of the APC controller requires adaption of the existing APC software
program either into the overriding system or into the drive via DriveAP or CoDeSys. Availability of the right
software tools and programming skills are to ensure.
© ABB Group
May 13, 2013 | Slide 17
DCS800-R Upgrade Kits
Upgrade Kits - Additional Information

Manual with detailed information



For further information regarding hardware, assembling and commissioning see Manual
3ADW00256R0101
Parameter settings

After upgrading parameters have to be adjusted due to different parameter groups in
DCS500/DCS600 and DCS800.

For parameter comparison see document 3ADW000405R0201
Sales Chanel

Product Sales and PartsOnline
© ABB Group
May 13, 2013 | Slide 18