NPort 5600 Series Quick

Installation Guide

Third Edition, November 2010

1. Overview

Welcome to the Moxa NPort 5600 Series. The NPort 5610-8/16 have 8 or 16 RS-232 ports, the NPort 5630-8/16 have 8 or 16

RS-422/485 ports, and the NPort 5650-8/16 have 8 or 16

RS-232/422/485 ports.

2. Package Checklist

The NPort 5600 package should contain the following items:

• 1 8-port or 16-port serial device server

• NPort Documentation & Software CD

• NPort 5600 Quick Installation Guide

Optional Accessories:

• CBL-RJ45M9-150: 8-pin RJ45 to DB9 male cable, 150 cm

• CBL-RJ45F9-150: 8-pin RJ45 to DB9 female cable, 150 cm

• CBL-RJ45M25-150: 8-pin RJ45 to DB25 male cable, 150 cm

• CBL-RJ45F25-150: 8-pin RJ45 to DB25 female cable, 150 cm

Notify your sales representative if any of the above items is missing or damaged.

3. Hardware Introduction

The NPort 5600 Series has includes the following models: NPort

5610-8, NPort 5610-16, NPort 5610-8-48V, NPort 5610-16-48V,

NPort 5630-8, NPort 5630-16, NPort 5650-8, NPort 5650-8-T,

NPort 5650-16, NPort 5650-16-T, NPort 5650-8-M-SC, NPort

5650-16-M-SC, NPort 5650-8-S-SC, and NPort 5650-16-S-SC.

NOTE The wide temperature model does not support LCM display panels or push buttons. All of the LCM descriptions below apply only to standard temperature models.

The front and rear panels are shown below:

Front panel of the NPort 5600 Series

Rear panel of the NPort 5610/5630/5650 (AC Power)

P/N: 1802056000211

– 1 –

Rear panel of the NPort 5650 (Fiber Model)

Rear panel of the NPort 5610 (DC Power)

Front panel of the NPort 5650-T Series

Reset Buttonpress the Reset button continuously for 5 sec to

load factory defaults: Use a pointed object to press the reset button. Release the button after the Ready LED stops blinking.

LED Indicators on the Front Panel—the front panels of the

NPort 5600 have several LED indicators, as described in the following table.

Name

Ready

1-16

Color

Off

Red

Function

Power is off, or power error condition exists.

Steady on: Power is on and the NPort is booting up.

Blinking: Indicates an IP conflict, or DHCP or

BOOTP server did not respond properly.

Green Steady on: Power is on and the NPort is functioning normally.

Blinking: The NPort has been located by NPort

Administrator’s Location function.

Orange Serial port is receiving data.

Green Serial port is transmitting data.

Off No data is being transmitted or received through the serial port.

LCM Display Panel—If the NPort is working properly, the LCM panel will display a green color. The red Ready LED will also light up, indicating that the NPort is receiving power. After the red

Ready LED turns green, you will see a display similar to:

N P 5 6 1 0 - 1 6 3 8

1 9 2 . 1 6 8 . 1 2 7 . 2 5 4

This is where

NP5610-16 is the NPort’s name

38 is the NPort’s serial number

192.168.127.254 is the NPort’s IP address

LCM Panel Operation—There are four buttons on the NPort

5600’s front panel. These buttons are used to operate the server’s

LCM panel. Going from left to right, the buttons are:

Button

MENU

︿

Action

Activates the main menu, or returns to a lower level.

Scrolls up through a list of items shown on the LCM panel’s second line.

– 2 –

SEL

Scrolls down through a list of items shown on the LCM panel’s second line.

Selects the option listed on the LCM panel’s second line.

Detailed LCM Panel Operating instructions can be found on the

CD-ROM in the NPort 5600 Series User’s Manual.

Link Indicator on the rear panel of the NPort 5650 fiber

model—the rear panels of the NPort 5650 have a link indicator, as described in the following table.

LED Name LED Color LED Function

Link Off Fiber disconnected.

Green

Blinking

Fiber connected; data not transmitting.

Fiber connected; data is transmitting.

4. Hardware Installation

STEP 1: After removing the NPort 5600 from the box, the first thing you should do is attach the power adaptor.

STEP 2: Connecting the Power.

AC: Connect the NPort 5600’s 100-240 VAC power cord to the AC connector. The “Ready” LED will show a solid red color until the system is ready, at which time it will change to a green color.

DC: Connect the NPort 5610-16/8-48V’s power cord to the DC connector, and then follow the steps given below:

Loosen the screws on the V+ and V- terminals of the NPort 5610-8/16-48V’s terminal block.

Connect the power cord’s 48 VDC or -48 VDC wire to the terminal block’s V+ terminal, and the power cord’s DC Power Ground wire to the terminal block’s V- terminal, and then tighten the terminal block screws. (Note: The NPort

5610-8/16-48V can still operate even if the 48V/-48V and DC

Power Ground are reversed.)

The “Ready” LED will show a solid red color until the system is ready, at which time it will change to a green color.

Grounding the NPort 5610-8/16-48V:

Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI).

Run the ground connection from the ground screw to the grounding surface prior to connecting devices. The Shielded Ground

(sometimes called Protected Ground) contact is the second contact from the right of the 5-pin power terminal block connector located on the rear panel of the NPort 5610-8/16-48V.

Connect the SG wire to the Earth ground.

STEP 3: Connect the NPort 5600 to a network. Use a standard straight-through Ethernet cable to connect to a hub or switch.

When setting up or testing the NPort 5600, you might find it convenient to connect directly to your computer’s Ethernet port. In this case, use a cross-over Ethernet cable.

– 3 –

STEP 4: Connect the NPort 5600’s serial port to a serial device.

Placement Options: You can place the NPort 5600 on a desktop or other horizontal surface.

5. Software Installation Information

To install NPort Administration Suite, insert the NPort

Document & Software CD into your computer’s CD-ROM drive.

Once the NPort Installation CD window opens, click on the

INSTALL UTILITY button, and then follow the instructions on the screen.

To view detailed information about NPort Administration Suite, click on the DOCUMENTS button, and then select “NPort 5600

Series User’s Manual” to open the PDF version of this user’s guide.

6. Pin Assignments and Cable Wiring

Serial Port Pinouts for the NPort 5610

Serial Port Pinouts for theNPort 5630

Pin RS-232

1 DSR (in)

2 RTS(out)

3 GND

4 TxD(out)

5 RxD(in)

6 DCD(in)

7 CTS(in)

8 DTR(out)

Pin RS-422/RS-485-4W RS-485-2W

1 – –

2

3

4

5

6

7

8

TxD+

TxD-

RxD-

RxD+

GND

Serial Port Pinouts for the NPort 5650

Data-

Data+

GND

4

5

6

7

8

Pin RS-232 RS-422/RS-485-4W RS-485-2W

1 DTR – –

2

3

RTS

GND

TxD+

GND

GND

TxD

RxD

DCD

CTS

DTR

TxD-

RxD+

RxD-

Data+

Data-

Serial Cables for the NPort 5630 (2-wire RS-485)

Serial Cables for the NPort 5630 (RS-422/4-wire RS-485)

Serial Cables for the NPort 5610/5650 (RS-232)

Serial Cables for the NPort 5650 (RS-422/4-wire RS-485)

Serial Cables for the NPort 5650(2-wire RS-485)

7. Specifications

Ethernet Interface

Speed

Protection

10/100 Mbps, RJ45

Built-in 1.5 KV magnetic isolation

Optical Fiber Interface (100BaseFX)

Wavelength

5650-8/16-M-SC 5650-8/16-S-SC

1300 nm 1310 nm

Transmitter power Max

Transmitter power Min

-10 dBm

-20 dBm

Receiver Sensitivity Max -6 dBm

Receiver Sensitivity Min -32 dBm

0 dBm

-5 dBm

-3 dBm

-34 dBm

Link Budget

Typical Distance

Power Requirements

Power Input

12dB

5 km

29 dB

40 km

100 to 240 VAC, 47 to 63 Hz, ±48 VDC (20 to 72 VDC, -20 to -72 VDC)

Power Consumption

NPort 5610-8/16: 141 mA for 100V, 93 mA for 240V

NPort 5610-8/16-48V: 135 mA (at 48V max.)

NPort 5630-8/16: 152 mA for 100V, 98 mA for 240V

NPort 5650-8/16: 158 mA @ 100 VAC, 102 mA @ 240 VAC

NPort 5650-8/16-S-SC: 164 mA @ 100 VAC, 110 mA @ 240 VAC

NPort 5650-8/16-M-SC: 174 mA @ 100 VAC, 113 mA @ 240 VAC

Other

Operating Temp. Standard Models: 0 to 55°C (32 to 131°F)

Wide Temp. Models: -40 to 75°C (-40 to

167°F)

5 to 95% RH Operating Humidity

Dimensions 190 × 45 × 478 mm (including ears)

190 × 45 × 440 mm (without ears)

Serial Line Protection 15 KV ESD for all signals

Power Line Protection Level 3 Burst (EFT), EN61000-4-4

Level 3 Surge, EN61000-4-5

Regulatory Approvals FCC Class A, CE Class A, UL 60950-1,

EN60950-1

– 4 – – 5 – www.moxa.com/support

The Americas: +1-714-528-6777 (toll-free: 1-888-669-2872)

Europe: +49-89-3 70 03 99-0

Asia-Pacific: +886-2-8919-1230

China: +86-21-5258-9955 (toll-free: 800-820-5036)

 2010 Moxa Inc., All Rights Reserved

– 6 –

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement