- Computers & electronics
- Computer components
- Interface components
- Serial servers
- Moxa
- NPORT 5650-8-S-SC
- Installation Guide
advertisement
NPort 5600 Series Quick
Installation Guide
Third Edition, November 2010
1. Overview
Welcome to the Moxa NPort 5600 Series. The NPort 5610-8/16 have 8 or 16 RS-232 ports, the NPort 5630-8/16 have 8 or 16
RS-422/485 ports, and the NPort 5650-8/16 have 8 or 16
RS-232/422/485 ports.
2. Package Checklist
The NPort 5600 package should contain the following items:
• 1 8-port or 16-port serial device server
• NPort Documentation & Software CD
• NPort 5600 Quick Installation Guide
Optional Accessories:
• CBL-RJ45M9-150: 8-pin RJ45 to DB9 male cable, 150 cm
• CBL-RJ45F9-150: 8-pin RJ45 to DB9 female cable, 150 cm
• CBL-RJ45M25-150: 8-pin RJ45 to DB25 male cable, 150 cm
• CBL-RJ45F25-150: 8-pin RJ45 to DB25 female cable, 150 cm
Notify your sales representative if any of the above items is missing or damaged.
3. Hardware Introduction
The NPort 5600 Series has includes the following models: NPort
5610-8, NPort 5610-16, NPort 5610-8-48V, NPort 5610-16-48V,
NPort 5630-8, NPort 5630-16, NPort 5650-8, NPort 5650-8-T,
NPort 5650-16, NPort 5650-16-T, NPort 5650-8-M-SC, NPort
5650-16-M-SC, NPort 5650-8-S-SC, and NPort 5650-16-S-SC.
NOTE The wide temperature model does not support LCM display panels or push buttons. All of the LCM descriptions below apply only to standard temperature models.
The front and rear panels are shown below:
Front panel of the NPort 5600 Series
Rear panel of the NPort 5610/5630/5650 (AC Power)
P/N: 1802056000211
– 1 –
Rear panel of the NPort 5650 (Fiber Model)
Rear panel of the NPort 5610 (DC Power)
Front panel of the NPort 5650-T Series
Reset Button—press the Reset button continuously for 5 sec to
load factory defaults: Use a pointed object to press the reset button. Release the button after the Ready LED stops blinking.
LED Indicators on the Front Panel—the front panels of the
NPort 5600 have several LED indicators, as described in the following table.
Name
Ready
1-16
Color
Off
Red
Function
Power is off, or power error condition exists.
Steady on: Power is on and the NPort is booting up.
Blinking: Indicates an IP conflict, or DHCP or
BOOTP server did not respond properly.
Green Steady on: Power is on and the NPort is functioning normally.
Blinking: The NPort has been located by NPort
Administrator’s Location function.
Orange Serial port is receiving data.
Green Serial port is transmitting data.
Off No data is being transmitted or received through the serial port.
LCM Display Panel—If the NPort is working properly, the LCM panel will display a green color. The red Ready LED will also light up, indicating that the NPort is receiving power. After the red
Ready LED turns green, you will see a display similar to:
N P 5 6 1 0 - 1 6 3 8
1 9 2 . 1 6 8 . 1 2 7 . 2 5 4
This is where
• NP5610-16 is the NPort’s name
• 38 is the NPort’s serial number
• 192.168.127.254 is the NPort’s IP address
LCM Panel Operation—There are four buttons on the NPort
5600’s front panel. These buttons are used to operate the server’s
LCM panel. Going from left to right, the buttons are:
Button
MENU
︿
Action
Activates the main menu, or returns to a lower level.
Scrolls up through a list of items shown on the LCM panel’s second line.
– 2 –
﹀
SEL
Scrolls down through a list of items shown on the LCM panel’s second line.
Selects the option listed on the LCM panel’s second line.
Detailed LCM Panel Operating instructions can be found on the
CD-ROM in the NPort 5600 Series User’s Manual.
Link Indicator on the rear panel of the NPort 5650 fiber
model—the rear panels of the NPort 5650 have a link indicator, as described in the following table.
LED Name LED Color LED Function
Link Off Fiber disconnected.
Green
Blinking
Fiber connected; data not transmitting.
Fiber connected; data is transmitting.
4. Hardware Installation
STEP 1: After removing the NPort 5600 from the box, the first thing you should do is attach the power adaptor.
STEP 2: Connecting the Power.
AC: Connect the NPort 5600’s 100-240 VAC power cord to the AC connector. The “Ready” LED will show a solid red color until the system is ready, at which time it will change to a green color.
DC: Connect the NPort 5610-16/8-48V’s power cord to the DC connector, and then follow the steps given below:
Loosen the screws on the V+ and V- terminals of the NPort 5610-8/16-48V’s terminal block.
Connect the power cord’s 48 VDC or -48 VDC wire to the terminal block’s V+ terminal, and the power cord’s DC Power Ground wire to the terminal block’s V- terminal, and then tighten the terminal block screws. (Note: The NPort
5610-8/16-48V can still operate even if the 48V/-48V and DC
Power Ground are reversed.)
The “Ready” LED will show a solid red color until the system is ready, at which time it will change to a green color.
Grounding the NPort 5610-8/16-48V:
Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI).
Run the ground connection from the ground screw to the grounding surface prior to connecting devices. The Shielded Ground
(sometimes called Protected Ground) contact is the second contact from the right of the 5-pin power terminal block connector located on the rear panel of the NPort 5610-8/16-48V.
Connect the SG wire to the Earth ground.
STEP 3: Connect the NPort 5600 to a network. Use a standard straight-through Ethernet cable to connect to a hub or switch.
When setting up or testing the NPort 5600, you might find it convenient to connect directly to your computer’s Ethernet port. In this case, use a cross-over Ethernet cable.
– 3 –
STEP 4: Connect the NPort 5600’s serial port to a serial device.
Placement Options: You can place the NPort 5600 on a desktop or other horizontal surface.
5. Software Installation Information
To install NPort Administration Suite, insert the NPort
Document & Software CD into your computer’s CD-ROM drive.
Once the NPort Installation CD window opens, click on the
INSTALL UTILITY button, and then follow the instructions on the screen.
To view detailed information about NPort Administration Suite, click on the DOCUMENTS button, and then select “NPort 5600
Series User’s Manual” to open the PDF version of this user’s guide.
6. Pin Assignments and Cable Wiring
Serial Port Pinouts for the NPort 5610
Serial Port Pinouts for theNPort 5630
Pin RS-232
1 DSR (in)
2 RTS(out)
3 GND
4 TxD(out)
5 RxD(in)
6 DCD(in)
7 CTS(in)
8 DTR(out)
Pin RS-422/RS-485-4W RS-485-2W
1 – –
2
3
4
5
6
7
8
–
TxD+
TxD-
RxD-
RxD+
GND
–
Serial Port Pinouts for the NPort 5650
–
–
–
Data-
Data+
GND
–
4
5
6
7
8
Pin RS-232 RS-422/RS-485-4W RS-485-2W
1 DTR – –
2
3
RTS
GND
TxD+
GND
–
GND
TxD
RxD
DCD
CTS
DTR
TxD-
RxD+
RxD-
–
–
–
Data+
Data-
–
–
Serial Cables for the NPort 5630 (2-wire RS-485)
Serial Cables for the NPort 5630 (RS-422/4-wire RS-485)
Serial Cables for the NPort 5610/5650 (RS-232)
Serial Cables for the NPort 5650 (RS-422/4-wire RS-485)
Serial Cables for the NPort 5650(2-wire RS-485)
7. Specifications
Ethernet Interface
Speed
Protection
10/100 Mbps, RJ45
Built-in 1.5 KV magnetic isolation
Optical Fiber Interface (100BaseFX)
Wavelength
5650-8/16-M-SC 5650-8/16-S-SC
1300 nm 1310 nm
Transmitter power Max
Transmitter power Min
-10 dBm
-20 dBm
Receiver Sensitivity Max -6 dBm
Receiver Sensitivity Min -32 dBm
0 dBm
-5 dBm
-3 dBm
-34 dBm
Link Budget
Typical Distance
Power Requirements
Power Input
12dB
5 km
29 dB
40 km
100 to 240 VAC, 47 to 63 Hz, ±48 VDC (20 to 72 VDC, -20 to -72 VDC)
Power Consumption
NPort 5610-8/16: 141 mA for 100V, 93 mA for 240V
NPort 5610-8/16-48V: 135 mA (at 48V max.)
NPort 5630-8/16: 152 mA for 100V, 98 mA for 240V
NPort 5650-8/16: 158 mA @ 100 VAC, 102 mA @ 240 VAC
NPort 5650-8/16-S-SC: 164 mA @ 100 VAC, 110 mA @ 240 VAC
NPort 5650-8/16-M-SC: 174 mA @ 100 VAC, 113 mA @ 240 VAC
Other
Operating Temp. Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 75°C (-40 to
167°F)
5 to 95% RH Operating Humidity
Dimensions 190 × 45 × 478 mm (including ears)
190 × 45 × 440 mm (without ears)
Serial Line Protection 15 KV ESD for all signals
Power Line Protection Level 3 Burst (EFT), EN61000-4-4
Level 3 Surge, EN61000-4-5
Regulatory Approvals FCC Class A, CE Class A, UL 60950-1,
EN60950-1
– 4 – – 5 – www.moxa.com/support
The Americas: +1-714-528-6777 (toll-free: 1-888-669-2872)
Europe: +49-89-3 70 03 99-0
Asia-Pacific: +886-2-8919-1230
China: +86-21-5258-9955 (toll-free: 800-820-5036)
2010 Moxa Inc., All Rights Reserved
– 6 –
advertisement