Noyes C850 Specs

Noyes C850 Specs
C850 Compact QUAD OTDR with QUAD OLS and OPM
C850 QUAD OTDR
•• Full Auto, Expert and Real-Time OTDR
test modes
•• Large transflective (indoor/outdoor) touch
screen display
•• Create professional certification reports
•• Perform Pass/Fail Event and Link
measurements
•• Find faults using integrated Visual Fault
Locator
•• Save loss or power measurements
•• Use as single-mode laser or multimode
LED source
© 2009, AFL Telecommunications, all rights reserved. C850-00-2000 Revision 1B, 2009-03-16
Specifications are subject to change without notice.
1
C850 Compact QUAD OTDR with QUAD OLS and OPM
The Noyes C850 from AFL Telecommunications is a full-featured
QUAD OTDR in a compact case with a large transflective touch
screen display suitable for both indoor and outdoor operation. The
C850 offers built-in auto test functionality when used with another
C850 or the C840 QUAD Certification Tester. The C850 features
MM and SM OTDR capabilities, both single-mode and multimode
Optical Light Sources (OLS), Visual Fault Locator (VFL, 650 nm),
and an Optical Power Meter (OPM). As an OTDR, the C850
supports Full Auto, Expert (manual) and Real-Time test modes,
simultaneous dual and single wavelength testing, and Event and
Pass/Fail analysis based on default or user-defined thresholds.
Two C850s or a C840 Tester and C850 can be used together
to perform Tier 1 dual wavelength MM (850/1300 nm) and SM
(1310/1550 nm) auto tests of one or two fibers in one or both
directions; and measure both loss and length of the fibers and
compare to industry standards (TIA/ISO/EN), applications and userdefined thresholds values to certify the fibers. The user may test
two fibers at two wavelengths bi-directionally and store the results
into the main unit. Featuring rich file naming, the Job setup wizard
allows the user to define both the cable and fiber end locations,
creating easily identifiable trace files, which are managed into Job
and Cable folders.
Features
•• 22 dB (MM), 26 dB (SM) dynamic range (OTDR)
•• LED 850/1300 nm and Laser 1310/1550 nm sources (OLS)
•• Integrated OPM and VFL (650 nm)
•• Transflective (indoor/outdoor) touch screen display
•• Tool-free, switchable adapters
•• Rechargeable Li-Ion battery (> 8 hours) or AC power
•• USB host and function ports
•• Bellcore (GR-196) .SOR file format
•• Internal (1000s test results) and USB storage
•• Wave ID detect if used with Noyes Wave ID series light sources
•• Windows® compatible software
Applications
•• Tier 1 and Tier 2 testing of premise networks
•• Fast fault location
•• Splice verification
•• Network documentation
•• Measure loss and length of fiber links
•• Certify fibers using Pass/Fail criteria of industry standards,
applications and user-defined limits
Continued on the next page
© 2009, AFL Telecommunications, all rights reserved. C850-00-2000 Revision 1B, 2009-03-16
Specifications are subject to change without notice.
2
C850 Compact QUAD OTDR with QUAD OLS and OPM
Ordering Information
When placing an order, select options as follows: Model, Optical Configuration, Language, and Case.
Example: C850 — 100 — LP1 — H2
C850
NNN
LLL
CC
Case (CC)
Model
C850
S1 = Soft case
H1 = Hard case and soft case with cleaning
accessories
H2 = Hard and soft case with SC-LC test and
cleaning accessories
H3 = H2 option plus OFS300-200X microscope
H4 = H2 option plus spare battery and charger
H5 = Hard and soft case with SC-ST test and
cleaning accessories
H6 = H5 option plus OFS300-200X microscope
H7 = H5 option plus spare battery and charger
Optical Configuration (NNN)
100 = QUAD 850/1300 nm MM and 1310/1550 nm SM
Language (LLL)
LP1 = Language Pack: English, German, French, Spanish, Italian, Portuguese
JPN = Japanese/English
CHI = Chinese/Taiwanese/English
RUS = Russian/English
KOR = Korean/English
ARA = Arabic/English
C850—100—LP1—H2 (or H5) Kit Contents
Optional OTDR and Cleaning Accessories
Item
Description
Model Number
Description
C850
QUAD OTDR/Auto Test Certification Tester
FR1-SM-150-SC-FC
Fiber ring, single-mode, SC/FC, 150 m
Adapters
OTDR and OLS ports — SC, ST, LC
OPM port — SC, 1.25 and 2.5mm Universal
VFI port — 1.25 and 2.5mm Universal
FR1-SM-150-SC-LC
Fiber ring, single-mode, SC/LC, 150 m
FR1-M6-150-SC-ST
Fiber ring, multimode, 62.5mm, SC/ST, 150 m
Fiber Rings (6)
150 m (62.5mm, 50mm, SM)
FR1-M6-150-SC-LC
Fiber ring, multimode, 62.5mm, SC/LC, 150 m
Miscellaneous
Accessories
Mandrel — 62.5mm, 3mm jacket
FR1-M5-150-SC-ST
Fiber ring, multimode, 50mm, SC/ST, 150 m
FR1-M5-150-SC-LC
Fiber ring, multimode, 50mm, SC/LC, 150 m
FR1-L5-150-SC-LC
Fiber ring, laser optimized, multimode, 50mm, SC/LC, 150 m
FR1-L5-150-SC-SC
Fiber ring, laser optimized, multimode, 50mm, SC/SC, 150 m
FR1-SM-500-SC-LC
Fiber ring, single-mode, SC/LC, 500 m
FR1-SM-500-SC-SC
Fiber ring, single-mode, SC/SC, 500 m
FR1-SM-500-SC-FC
Fiber ring, single-mode, SC/FC, 500 m
8500-20-0900
Wet Cleaning Kit for SC/FC/ST/LC Connectors
8500-05-0001MZ
One-Click Cleaner SC/ST/FC
8500-05-0002MZ
One-Click Cleaner LC/MU
8500-10-0017MZ
Replacement tape for Cletop (white)
Mandrel — 50mm, 3mm jacket
Stylus pen for touch screen
USB thumb drive, 1G
USB to mini-USB cable
Small plastic parts box (2) to store adapter caps and mandrels
AC adapter (1), specify country of use
Cleaning
Accessories
One-Click Cleaner SC/ST/FC, 2.5mm (H2 and H5 kit)
One-Click Cleaner LC/MU, 1.25mm (H2 kit only)
Cletop SB white tape
Cases
Hard transit case — holds C850, and above accessories
Note: 1000 m single-mode fiber rings are also available.
Soft case for C850
Documentation
User guides and quick reference guides
Report Software PC software and user guide
Continued on the next page
© 2009, AFL Telecommunications, all rights reserved. C850-00-2000 Revision 1B, 2009-03-16
Specifications are subject to change without notice.
3
C850 Compact QUAD OTDR with QUAD OLS and OPM
Specifications
(All specifications valid at 25°C unless otherwise specified)
OTDR
Multimode
Single-mode
Emitter Type
Laser
Safety Class
Class I FDA 21 CFR 1040.10 and 1040.11,
IEC 60825-1: 2007-03
Center Wavelengths
Wavelength Tolerance
850/1300 nm
1310/1550 nm
± 20/30 nm
± 20/30 nm
22 dB
26 dB
Dynamic Range (SNR = 1)
10, 30, 100, 300 ns; 1, 3, 10 ms
Pulse Widths
Range Settings
250 m to 64 km
Distance Sampling Points
250 m to 208 km
0.25 m (range 4 km),
Range/16000 (range 8 km)
Group Index of Refraction (GIR)
InGaAs 2mm
Measurement Range
+6 to -60 dBm
Accuracy 1
±0.25
2
dB, dBm, mW
Yes (to -47 dBm)
Set Reference
Yes
Data Storage
Yes
Tone Detection
Yes (to -47 dBm)
1 Accuracy measured at 25ºC and -10 dBm per N.I.S.T. standards.
2 Automatic wavelength identification and switching when used with Noyes Wave
ID Series Light Sources.
Up to 16,000
Data Point Spacing
850, 980, 1300 1310, 1490, 1550, 1625 nm
Detector Type
Wavelength ID
9m
Attenuation Dead Zone 2
Calibrated Wavelengths
Measurement Units
1.5 m
Event Dead Zone 1
Distance Uncertainty (m) 3
Power Meter
1.4000 to 1.6000
general
C850 OTDR
± (1 + 0.005% x distance + data point spacing)
Test Modes
OTDR (Full Auto, Expert, Real-Time), Auto Test, OPM,
OLS, VFL
Trace File Format
SR-4731 (GR-196-CORE Appendix A, B; SR-4731)
Loss Measurement Accuracy
(linearity)
± 0.05 dB/dB
Length Measurement Range
1 Typical distance between the two points 1.5 dB down each side of a reflective
spike caused by a -45 dB event using 10 ns pulse width.
2 Typical distance from event location to point where trace is within 0.5 dB of
backscatter caused by a -45 dB event using 10 ns pulse width.
3 Does not include GIR uncertainty.
Data Storage
5 km (MM);
200 km (SM)
Internal flash memory
USB flash drive (2.0)
Downloadable from unit directly to PC
Light Source
Available Wavelengths
Multimode port
850/1300 ± 30 nm
Emitter Type
Safety Class
Output Power
Stability (after 15 minutes
warm up)
Data Storage Capacity
Single-mode port
1310/1550 ± 30 nm
LED
Laser
> - 20 dBm, 62.5µm MM 1
0 dBm, 9µm SM
± 0.1 dB over 1 hour
± 0.07 dB over 1 hour
± 0.15 dB over 8 hours
Wave ID Transmit
Yes
Tone Generation
270 Hz, 330 Hz, 1 kHz, 2 kHz
Laser
Class II FDA 21 CFR 1040.10 and 1040.11,
IEC 60825-1: 2007-03
Wavelength
650 nm
Output Power (nominal)
0.8 mW
27.4 x 19.3 x 7.1 cm
(10.8 x 7.6 x 2.8 in)
2.3 kg ( 5 lb)
Operating Temperature
-10 to +50°C, 0 to 90% RH (non-condensing)
Storage Temperature
-20 to +60°C, 0 to 90% RH (non-condensing)
Power
Battery Life 1
Recharge Time 2
Display
Rechargeable Li-Ion or AC power adapter
> 8 hours continuous testing
4 hours
16.51 cm (6.5 in),
color, transflective
1 Typical, depending on display brightness.
2 Typical, from fully discharged to fully charged state, unit may be operating.
External battery charger available.
Visual Fault Locator
Safety Class
Modular cleanable SC/ST/LC
Weight
1 Output power will be approximately 3 dB less if a 50 µm mandrel-wrapped
jumper is used instead of a 62.5 µm mandrel-wrapped jumper.
Emitter Type
USB
Tool Free Adapters
Size
Class I FDA 21 CFR 1040.10 and 1040.11,
IEC 60825-1: 2007-03
Internal > 1000 fibers
Data Transfer to PC
© 2009, AFL Telecommunications, all rights reserved. C850-00-2000 Revision 1B, 2009-03-16