INSTALLATION GUIDE *
K3590-3V1 3/00
REMOTE KEYPADS
6150PL3 & 6160PL3
INSTALLATION GUIDE
6150PL3
Fixed-Word
YES (See Note 1)
YES
Piezo
Keypad Features
Backlit Display
Dedicated Function Keys
Built-in Sounder
6160PL3
2-Line Alpha
YES (See Note 1)
YES
Speaker
Notes1.Permanent display backlighting is an option on some controls (see the control's instructions for details).
GENERAL INFORMATION
WIRING AND INSTALLATION
The 6150PL3 and 6160PL3 are addressable Remote
Keypads designed for use with SecurityLink control panels.
Addresses are set via the keypad keys.
The keys on the keypads are continuously backlit for
convenience.
The keypads can be surface mounted directly to a drywall, or to
a single- or double-gang electrical box.
1. Remove the case back by pushing down two "snaps."
See diagram below.
2.
Route wiring from the control panel through the
opening in the case back.
KEYPAD DISPLAYS AND LEDS
3.
Mount the case back to a wall or electrical box.
The keypads have the following display features:
4.
Wire directly from the keypad’s terminal block to the
terminal block on the control board. Wire functions are
marked next to terminals. Labels are as follows: DI Data
In to Control Panel, - Ground, + Aux. Power Plus, DO Data
Out of Control Panel. See the control panel’s Installation
Instructions for more complete details.
5.
Re-attach the keypad to its case back.
Model
6150PL3
Fixed
Word
Display
X
2-line
Alpha
Display
6160PL3
2-digit
Zone
Identifier
X
Custom
Zone
Descriptors
X
X
The following table shows the LEDs and their functions:
LED
Red
Function
Lights when the system is armed in any mode
Green
Lights when the system is "ready" to be armed.
SPECIAL FUNCTION KEYS
SIDE VIEW
The keypads also feature function keys. These keys may be
programmed for panic alarms or other special functions
such as macros. See the control's instructions for details.
Function keys must be held down for at
least 2 seconds to activate an alarm, key
pairs activate immediately.
Function Key
Corresponding Key
Pair
A
[1] & [*]
B
[*] & [#]
C
[3] & [#]
D
NONE
ARMED
A
1
OFF
2 AWAY
3 STAY
READY
B
4 MAX
5 TEST
6 BYPASS
C
7
8
9 CHIME
D
*
INSTANT
READY
0
CODE
#
MOUNTING RELEASE SNAPS
(Remove case back by pushing
up the 2 "snaps" along the
keypad's bottom edge and
pulling the case apart.)
SETTING THE KEYPAD ADDRESS
SPECIFICATIONS
The keypad can either be set for an address of 00-30, or to
the non-addressable mode (31). The keypad's default
address is 31.
Physical:
6150PL3:
6160PL3:
To change the keypad's address, do the following:
1. Enter address mode: Power up the keypad. Within 60
seconds of power-up, press and hold down the [1] and [3]
keys at the same time for 3 seconds. (If unable to enter
address mode, power up and try again.)
The current keypad address will be displayed, and the
cursor will be under the "tens" digit. If 10 seconds have
passed with no key entry, the keypad automatically
exits address mode. You must power down, power up
and start address mode again.
NOTE: The keypad will not enter address mode if the
panel to which it is connected is in programming mode.
2. Set the current address to "00": Press [0] to clear the
current "tens" digit. The cursor will move to the "ones"
digit position. Press [0] to clear the current "ones" digit.
The cursor will move back to the "tens" digit position.
3. Enter the keypad's address: Enter the proper "tens" digit
of the keypad's address. The cursor will move to the
"ones" digit position. Enter the proper "ones" digit of the
keypad's address. Note that address "31" sets the
keypad to non-addressable mode.
4. Exit address mode:
Press [✱] to save the displayed address and exit address
mode.
5-1/4"H x 6-1/2"W x 1-5/16"D
5-1/4"H x 7-1/4"W x 1-1/2"D
Wiring (all Keypads):
DI (Green):
“Data In” to control panel
- (Black):
Ground
+ (Red):
+12VDC (Aux. Power)
DO (Yellow): “Data Out” from control panel.
Displays:
6150PL3:
6160PL3:
Sounder:
6150PL3:
6160PL3:
Current:
6150PL3:
6160PL3:
Fixed-Word LCD (backlit).
2 x 16 alpha-numeric supertwist LCD, backlit.
Piezo-electric (fire alarm is loud, pulsing single
tone; (all Keypads) burglary alarm is loud,
continuous, dual tone).
Speaker.
70mA (ARMED LED lit, LCD backlight and
sounder on), reduces to 40mA when panel is
operating in standby mode (backlight off).
150mA (ARMED LED lit, LCD backlight and
sounder on), reduces to 40mA when panel is
operating in standby mode (backlight off).
VIEWING THE KEYPAD ADDRESS
Press and hold down the [1] and [3] keys at the same time
for about 3 seconds. The current address is displayed. No
key entry is allowed. Press any key to exit or wait 10
seconds to exit viewing mode.
REFER TO INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED
FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM.
165 Eileen Way
Syosset, NY 11791
Copyright  2000 PITTWAY CORPORATION.
¬.9^l
K3590-3V1 3/00
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising