Technical Specifications

Technical Specifications
Main House Technical Specification
Technical Stage Manager:
Shaun Luckly
Tel: 01202 499199 EXT 202
Email: shaun@regentcentre.co.uk
Senior Technician:
Tom Critchell
Tel: 01202 499199 EXT 214
Email: tom@regentcentre.co.uk
Nearest train station: Christchurch
Population: 47,300
Distance to London: 105 miles
Stage:
Type of Stage: Proscenium/Thrust
Rake: None
Surface: Black hardwood floor with the ability to screw in
Stage Management:
We have a stage managements desk available stage left fitted with intercom and show relay. This
is a fixed position.
Cue Light System: None
FOH calls available: Yes
Dimensions:
Apron Width: 7040mm
Apron Depth: 3450mm
Proscenium Width: 9210mm
Proscenium Height: 8000mm
Grid Height: 8500mm
Stage Right Wing: 1610mm x 4750mm
Stage Left Wing: 1600mm x 4750mm
Please consult the attached plan for more information.
The Regent Centre Technical Specification 2014
51 High Street, Christchurch, BH23 1AS Tel: 01202 499199
Flying:
The Regent Centre uses manual hemp, hand winch and motor hoist flying systems. Please
consult the flying plan attached for the positions of each bar as well as the type of flying and safe
working load allocations.
Please be aware that the Regent Centre has a Safe Working Load of 1210kg uniformly
distributed across the Grid. There is an allowance of 600kg for touring companies to hang on the
grid together with the in house rigging. If you require anymore information contact the technical
department.
Equipment:
1
1
1
1
1
4
3
4
Large Zarges
Set of House Tabs (Red)
White Cyclorama
Blacks
Black Cloth
Black Legs
Black Borders
8 x 4 black steel deck
Backstage:
The Regent Centre has a load in door 1400mm above the ground located in the Stage Right wing
but does not have an in house ramp. Please bare this in mind for your fit ups.
Dressing Rooms: 3
Shower Toilets: 2 with ensuite showers and 1 with a toilet.
Access to stage: Via the backstage crossover on the stage level or through the auditorium.
Orchestra Pit:
Orchestra Pit Size: 6400mm x 2200mm
Lit Music Stands: 7
Chairs: 30 armless
Power:
125amp 3 phase distro to 16a, 32amp
The Regent Centre Technical Specification 2014
51 High Street, Christchurch, BH23 1AS Tel: 01202 499199
Lighting Control:
1
3
ETC ION with 2x20 Master Fader Wing
ADB Eurorack 60 24 x 3kw Dimmers
Moving Heads:
6
PR 1200 spots
Profiles:
20
12
6
ETC Source 4 Junior Zoom 25° - 50°
ETC Source 4 Zoom 15° - 30°
Selecon Zoom 08° - 16°
Fresnel’s:
12
2
6
6
CCT Starlette 1KW Fresnel
Selecon 1.2KW Fresnel
ETC Source 4 Parnel
Thomas 1KW Fresnel
Par Cans:
40
4
4
Thomas Par64
Thomas Par64 Short Nose Floor Cans
LED par cans
Floods:
15
RGB LED batons.
Followspots:
2
Robert Juliat Korrigan 1200HMI followspots with Laser Sights
Accessories:
Various gobo’s are available as well as barn doors for all Fresnel lanterns. We have a large stock
of cheats and adapters available.
Cables:
40
15A TRS
10
3 pin DMX
The Regent Centre Technical Specification 2014
51 High Street, Christchurch, BH23 1AS Tel: 01202 499199
Please consult the in house lighting plan for locations of the lanterns in our house rig.
Sound:
The Regent Centre has 3 Yamaha XLR to Cat 6 Audio boxes. Available at the racks and Down
Stage Right,
The Audio mix position is within the open control room at the back of the auditorium.
Mixers:
1
Yamaha M7cl 48 channel digital mixer
Main House PA:
4
EV SX300 2 way 600w FOH speakers (flown)
2
JBL Control 12 speakers
2
EV Powered Subs
2
Crest Audio DX2000 Amp
This is a fixed system and cannot be relocated.
Monitors:
4
HK Audio Pro series
2
QSC series RMX 1850 HD Amps
Processors:
2
EV One PA Crossover and Processor
Playback:
1
Macbook
Microphones:
10
Shure SM58 Dynamic Microphone
5
Shure SM57 Dynamic Microphone
2
AKG C1000s
Drum Mics
The Regent Centre Technical Specification 2014
51 High Street, Christchurch, BH23 1AS Tel: 01202 499199
1
EV PL33
4
EV PL35
2
Audio technical pro37
Misc Equipment:
10
Tall Microphone Stands
4
Short Microphone Stands
Communications:
The Regent Centre has a Triple Circuit communications system as well as audio and video show
relay. Please contact the technical department for a detailed plan of the location of the
communications packs.
8
Single Circuit belt packs both located at designated positions and spare.
Cables:
24
3 pin XLR cables (various lengths)
Various cheats and adaptors are available as well as XLR to jack and other combinations.
Audio/Visual:
1
Barco DP2K-19B Digital Projecter with 5.1 surround cinema system
1
Sanyo Projector on the Front of House Truss
1
LANsat satilites receiver and hard drive recorder
1
DOREMI Cinema System
Electrics:
The Regent Centre has dedicated 1 x 16A Audio power located under the orchestra pit.
The Regent Centre Technical Specification 2014
51 High Street, Christchurch, BH23 1AS Tel: 01202 499199
Cables:
5
4 way 16A extension leads
10
4 way 13A extension leads
Various cheats and adapters are available.
SAFETY
All performance companies using The Regent Centre must ensure and demonstrate (if required)
that they can use and operate the theatre’s equipment in a safe and competent manner.
All scenery, props, costumes etc. must conform to fire regulation standards where appropriate
and that flame-retardants conform to BS3119/3120 BS476 parts 5,6 & 7 (class 1 & 0).
All rigging using ladders must be conducted in a competent manner and in accordance with
current health and safety guidelines.
Under no circumstance must any fire exit or fire exit route be obstructed internally and externally.
It must be the duty of the responsible person in charge of the company to make their colleagues
aware of their nearest fire exit and muster point.
ELECTRICAL SAFETY
The Electricity At Work regulations 1989 (EAW), requires all portable electrical equipment to be
regularly inspected and tested to check that it is safe for use at work. This means that it is now a
legal requirement that all electrical equipment used in performances and used in the set
construction on site is PAT tested (Portable Appliance Test). Any equipment brought in to The
Regent Centre, that in the opinion of the Technical department, does not comply with current PAT
- Electricity At Work regulation will not be deemed fit for use and must not be used until the fault
or faults have been corrected and it has been re-tested to meet current legal requirements. Proof
of test may be required.
NOTE
Under no circumstances must equipment or cables belonging to The Regent Centre be tampered
with, adapted or have its connectors removed without prior permission or consultation with the
Technical department.
ALL trailing extensions and cables must be secured so as not to constitute a trip hazard.
Please contact the Technical Manager with specific requests, for lighting & sound equipment, as
we can not guarantee that all items on this list will be available for use all of the time.
The Regent Centre Technical Specification 2014
51 High Street, Christchurch, BH23 1AS Tel: 01202 499199