SELECT YOUR TYPE OF CLAMP
Answering the following questions will help you select the best clamp for your application:
• Determine if you are measuring an alternating current or a continuous one.
The clamps for continuous current are indexed in AC-DC as they measure the both .
• Determine the range from the lowest and higrest currents
• Check that the accuracy, on low level, is suitable or choose a clamp for lower current.
•
•
•
•
Most of the clamps have a better accuracy on the higher ranges.
What is the size of the conductor where you will perform the measurement ?
(This parameter determines the jaw size).
In this price list, the clamps are sorted in an ascending size order.
What type of signal accepts the instrument on which the clamp will be connected ?
- nature of the signal: current or voltage ? , AC orDC ?
- their ranges ?
- the impedance of the instrument ?
Which type of connector do you want?
Safety sockets, cable + banana plugs or BNC? etc...
Will the clamp be used for measuring harmonics or power ?
If so, look at specifications on frequency and phase shift.
Other important factors to consider:
The MAX. voltage compared to the conductor’s GROUND.
Signification of the symbols introduced by the new Standard ICE61010-2-032 of 09/2002:
Nude conductors under dangerous voltage, below 600V
Insulated conductors or voltage below 30V MAX. rms
These symbols stand on each page, in the drawings, near or between the clamp’s jaws .
The clamps Universal Technic can fit all your needs !
This price list is published to guide you in your choice and to facilitate the writing of your orders.
It is only an overview of our production classified by growing order of input current level.
The “Types” are available in A “Range”, from which the reference is composed “Range+Extension”.
The Extension defines the nature of the “Treatment” of the secondary internal signal.
In order to adapt itself to all the reading equipment, a Clamp can deliver a secondary signal under the form of
a “Current”, an (AC) “alternative Voltage”, of a “Current” and an AC “Voltage”, or still of a (DC) “continuous
Voltage”, etc...
For more details see :
“Typical electric schemes of the Clamp-on CurrentTransformers - Part 1 and 2”
see on page 51.
For further informations, do not hesitate to contact us.
In order to deliver quickly a product in conformity with your request, we thank you for formulating like the
model below.
Nature of the current to measure Alternating (AC) frequency 50Hz
Type of clamp
Primary
Secondary
Special output
Colour
M1.UB
25A
2V
Bifilar lead + plugs 4 mm
Blue
Page 2
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Edition 1
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Conductors diameter 15 mm
CLAMP-ON CURRENT TRANSFORMERS AC
M1
RANGE
Input AC.
Output AC current................................
Output AC voltage ................................
1mA...200A AC
M1.
M1. B
M1.U
M1.UB
P.9
M1.UB5
M1.UB5W
Emitting clamp
Output AC current or voltage ..............
M1.MB
...............................................................
M1.I
M2
RANGE
Input AC.
Output current........................................
M2.
Output AC voltage..................................
M2.U
M2.UB
M2.UB5
M2.UB5W
Output DC voltage.................................
M2.V
M2.VB
M3
RANGE
Input AC.
Output current........................................
Output AC voltage..................................
Emitting clamp
RANGE
Input AC.
10mA...300A AC
10mA...300A AC
M3.
M3. B
M3.U
M3.UB
M3.UB5
M3.UB5W
Output AC current or tension.................
M3.MB
...............................................................
M3.I
M4
P.10
P.11
10mA...300A AC
Output current.......................................
M4.
Output AC voltage..................................
M4.U
M4.UB
M4.UB5
P.12
M4.UB5W
Output DC voltage...........................
M4.V
M4.VB
“Special Outputs”, Cables with choice of the connectors, see
page: 51
supplements
“Typical Electrical schemes of the Clamp-on Current Transformers-Part 1 and 2” last pages.
Other colours - Other ratios: please contact us. Special makings on demand.
Page 3
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Edition 1
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
For conductors
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
100mA...1000A AC
US
Output current
Output current (protected)
US
US.P
P13
Output DOUBLE voltage and current
Output DOUBLE voltage and current (protected)
Emitting clamp
US.D
US.DP
US.I
P14
Output AC Voltage
US.U
US.UB
US.UE
US.V
US.VB
P15
Output AC voltage (economic type)
Output DC voltage
RANGE
100mA...1000A AC
NS
Output current
Output current (protected)
NS
NS.P
P16
Output DOUBLE voltage and current
Output DOUBLE voltage and current (protected)
Emitting clamp
NS.D
NS.DP
NS.I
P17
Output AC voltage
Output AC voltage (economic type)
NS.U
NS.UE
P18
Output DC voltage
NS.V
RANGE
S
Output current
Output protected current
Output DOUBLE voltage and current
Output DOUBLE voltage and protected current
Emitting clamp
Output AC voltage
Output AC voltage (economic type)
Output DC voltage
RANGE
SM
Output current
Output protected current
Output DOUBLE voltage and current
Output DOUBLE voltage and protected current
Emitting clamp
Output AC voltage
Output economical AC voltage
Output AC voltage speciale frequency
Output DC voltage
10mA...1200A AC
S
S.P
S.D
S.DP
S.I
S.U
S.UB
S.UE
S.V
S.VB
Page 4
Diameter MAX.: 50 mm
Diamètre MAX.: 50 mm
P19
P20
P21
1mA...1400A AC
SM
SM.B
SM.P
SM.D
SM.DP
SM.I
SM.U
SM.UB
SM.UE
SM.UF
SM.UBF
SM.V
SM.VB
Diameter MAX.: 43 mm
P22
P23
P24
Diameter MAX.: 54 mm
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Edition 1
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Cables/ Bus Bars (mm)
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
AC Input
1A...1600A AC
E16
Output current........................................
Output (protected) current..........................
E16
E16.P
P.25
Output DOUBLE voltage and current.......
E16.D
P.26
Ø 54/100x30...120x20
Output DOUBLE voltage and current (protected) E16.DP
E16.U
E16-UE
E16.V
Output AC voltage.................................
Output AC voltage (economic type)......
Output DC voltage..................................
RANGE
AC Input
1A...1600A
H16
AC Input
Ø 67/100x44...120x35
Output current................................................
Output (protected) current..........................
Output multi ratio current ................................
Output DOUBLE voltage and current...............
Output DOUBLE voltage and current (protected)
H16
H16.P
H16
H16.D
H16.DP
H16.I
P.28
Output AC voltage...........................................
Output AC voltage (economic type)................
Output DC voltage...........................................
H16.U
H16-UE
H16.V
P.30
Emitting clamp
RANGE
P.27
P.29
1A....1600A
P16
Ø 80/100x56...120x48
Output current...................................................
Output (protected) current..........................
Output multi ratio current...................................
P16
P16.P
P16
P.31
Output DOUBLE voltage and current.................
Output DOUBLE voltage and current (protected)
P16.D
P16.DP
P16.I
P16.U
P16-UE
P16.V
P.32
Emitting clamp
Output AC voltage............................................
Output AC voltage (economic type).................
Output DC voltage............................................
Page 5
P.33
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Edition 1
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Cables/ Bus Bars (mm)
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
AC Input
1A...3200A AC
E32
E32
E32.P
Output current...................................................
Output current (protected) .................................
DOUBLE Output voltage and current.................. E32.D
DOUBLE Output voltage and current (protected) E32.DP
E32.U
Output AC voltage.............................................
Ø 56/100x32...120x20
P.34
P.35
P.36
E32-UE
Output AC voltage (economic type)..................
Special version for leakage current measurement E32.UEB5
E32.V
Output DC voltage.............................................
:
1,4 kg
RANGE
AC Input
1A...3200A AC
H32
H32
H32.P
Output current...............................
Output current (protected) .................................
H32.D
DOUBLE Output voltage and current.......
DOUBLE Output voltage and current (protected) H32.DP
Output AC voltage..........................
Output AC voltage (economic type)......
Special version for leakage current measurement
Output DC voltage..........................
H32.U
H32.UE
H32.UEB5
H32.V
Ø 70/100x45...120x35
P.37
P.38
P.39
1,6 kg
RANGE
AC Input
1A.....3200A AC
P32
Output current...............................
Output current (protected) .................................
P32.
P32.P
P.40
DOUBLE Output voltage and current.......
P32.D
P.41
Ø 82/100x58...120x50
DOUBLE Output voltage and current (protected) P32.DP
Output AC voltage...........................
Output AC voltage (economic type)......
Special version for leakage current measurement
Output DC voltage..........................
P32.U
P32.UE
P32.UEB5
P32.V
P.42
1,8 kg
Page 6
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Edition 1
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
CLAMP-ON CURRENT (Hall effect)
RANGE
AC-DC Input
RANGE
AC-DC Input
RANGE
AC-DC Input
RANGE
AC-DC Input
M2 C AC-DC
Output AC-DC voltage........................
SC AC-DC
1A...300A AC-DC
M2.C
Output AC-DC voltage....................
Output AC-DC voltage....................
Output AC-DC voltage.......................
Output AC-DC voltage......................
Output AC-DC voltage.......................
Output AC-DC voltage.......................
PC AC-DC
P.43
1A...2000A AC-DC
S .C
Output AC-DC voltage.....................
HC AC-DC
Conductors diameter 15 mm
AC-DC
P.43
1A...5000A AC-DC
H20.1C
H40.1C
H50.1C
H20.3C
H40.3C
H50.3C
Output AC-DC voltage.....................
Output AC-DC voltage.....................
Output AC-DC voltage.....................
Output AC-DC voltage.....................
Output AC-DC voltage.....................
Output AC-DC voltage.....................
Output AC-DC voltage.....................
Output AC-DC voltage.....................
P20.3C
P40.3C
P50.3C
P75.3C
Ø 72/100x53...127x43
P.44
1A...7500A AC-DC
P20.1C
P40.1C
P50.1C
P75.1C
Diameter MAX.: 50 mm
Ø 83/100x64...122x54
P.45
For the AC-DC clamps, transformation ratio is expressed at maximum value.
1,8 kg
Page 7
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Edition 1
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Cables/ Bus Bars (mm)
TRANSDUCERS
C 104 AC-DC
RANGE
Input AC-DC
Ø 100/104x104
200A...15000A
Output voltage ............
Supply : 36V à 72Vdc
Output voltage ..............
Supply : 220V eff. 50-60Hz
Output voltage ..............
C 104.CT
P.46
C 104.AS
C 104.AT
Supply : 220V eff. 50-60Hz
MEASUREMENT AUXILIARIES
MEASURMENT PLUGS
For SECURA system.
P.47
Current
Accessories
For ESSAILEC system.
Voltage
3 Phases
Accessories
Signals
STC
T.I. 2500/1
GENERALITIES
CALIBRATION CERTIFICATE ( B.N.M )
For all the clamps
P.48
Typical electrical shemes
Part 1
Part 2
P.49
P.50
Output connections, Options, Special outputs
Output connections
P.51
Weight and packing
P.51
General Sales Conditions
P.52
Page 8
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
MICROCLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Codes
♦
♦
M1
1 mA ......200A AC
TYPE
Output connections
U.P
Euros
Grey
75
Ouptut current.
M001
M1
M009
M232
M1
M1
M1.B
M1.B
200A / 200mA
100A
200A
100A
10A
/
/
/
/
Safety sockets Ø4 mm.
1A
1A
100mA
4mA max
78
79
102
113
Output AC voltage.
M233
M008
M1.U
M1.U
M1.U
100A / 1Vac
200A / 2Vac
200A / 10Vac
Safety sockets Ø4 mm.
Blue
81
Safety sockets Ø4 mm.
Blue
82
M234
M235
M236
M237
M005
M1.UB
M1.UB
M1.UB
M1.UB
M1.UB
1A
5A
5A
5A
5A
/
/
/
/
/
1Vac
1Vac
2Vac
3Vac
5Vac
Safety sockets Ø4 mm.
Blue
130
124
M004
M014
M239
M240
M1.UB
M1.UB
M1.UB
M1.UB
10A
10A
10A
10A
/
/
/
/
1Vac
2Vac
3Vac
5Vac
Safety sockets Ø4 mm.
Blue
124
M241
M242
M243
M244
M1.UB
M1.UB
M1.UB
M1.UB
20A
20A
20A
20A
/
/
/
/
1Vac
2Vac
3Vac
5Vac
Safety sockets Ø4 mm.
Blue
124
M245
M246
M247
M248
M1.UB
M1.UB
M1.UB
M1.UB
50A
50A
50A
50A
/
/
/
/
1Vac
2Vac
3Vac
5Vac
Safety sockets Ø4 mm.
Blue
124
5A / 1Vac
5A / 1Vac
Safety sockets Ø4 mm.
Blue
138
171
Safety sockets Ø4 mm.
Green
127
M1.UB5
M1.UB5W
♦
Colour
MIXED output current or AC voltage.
M891
M1.MB
300A / 300mA
30A / 3Vac
Emitting clamp-on
M1345
M1.I
for alternating current
Emitting
Alls the clamps can be designed by us in order to inject signals on cables.
Applications: Cable fault location, current flow, cables identification, ...
“Special outputs ”, Cables and leads with choice of the ends, see
page: 51
supplements
“Typical electrical scheme of the Clamp-on current transformers-Part 1 and 2” last pages.
Other colours - Other ratios : manufactured on request, please contact us.
Page 9
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
MICROCLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Codes
♦
TYPES
M2
M2
M2
M2.B
M254
M279
M280
M256
M257
M258
M259
M260
M261
M262
M263
M264
M265
M266
M267
M268
M269
M270
M2.U
M2.U
M2.U
M2.UB
M2.UB
M2.UB
M2.UB
M2.UB
M2.UB
M2.UB
M2.UB
M2.UB
M2.UB
M2.UB
M2.UB
M2.UB
M2.UB
M2.UB
M281
M282
M2.UB
M2.UB
Colour
UP
Euros
Grey
96
100
200A
100A
200A
100A
/
/
/
/
200mA
1A
1A
100mA
Safety sockets Ø4 mm.
200A
50-100-200A
50-100-200A
1A
5A
5A
5A
5A
10A
10A
10A
20A
20A
20A
20A
50A
50A
50A
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
2Vac
1Vac
2Vac
1Vac
1Vac
2Vac
3Vac
5Vac
1Vac
2Vac
5Vac
1Vac
2Vac
3Vac
5Vac
1Vac
2Vac
5Vac
Safety sockets Ø4 mm.
Blue
Blue
100
151
Safety sockets Ø4 mm.
Blue
151
145
Safety sockets Ø4 mm.
Blue
145
Safety sockets Ø4 mm.
Blue
145
Safety sockets Ø4 mm.
Blue
145
5-10-20A / 1Vac
25-50-100A / 1Vac
Safety sockets Ø4 mm.
Blue
177
5A / 1Vac
5A / 1Vac
Safety sockets Ø4 mm.
Blue
170
201
200A / 1Vdc
200A / 2Vdc
50-100-200A / 1Vdc
Safety sockets Ø4 mm.
Blue
119
123
Output DC voltage
M271
M272
M273
M274
M275
M276
M277
M278
•
•
Output connections
Output AC voltage
M2.UB5
M2.UB5W
♦
10 mA ......300A
Ouptut current
M249
M252
M253
♦
M2
M2.V
M2.V
M2.V
M2.VB
M2.VB
M2.VB
M2.VB
M2.VB
M2.VB
M2.VB
25A
50A
100A
25A
50A
100A
25-50-100A
/
/
/
/
/
/
/
1Vdc
1Vdc
1Vdc
2Vdc
2Vdc
2Vdc
1Vdc
151
Safety sockets Ø4 mm.
Blue
162
Safety sockets Ø4 mm.
Blue
185
For all the voltage output, other values are available between 0,2V and 5V. Please contact us.
For all the voltage output, all kind of cables and ends are available.
WARNING: Probes with voltage output must be connected to instruments with high impedance (>= 1 Mohm).
For any lower impedance (eg 10 kohm) please contact us.
“Special outputs”, Cables and leads with choice of the ends, see
page: 51
“Typical electrical schemes of the clamp-on current transformers - Part 1 and 2” last pages.
suppléments
Other colours - Other ratios : manufactured on request, please contact us.
♦
Transport suitcase for Clamps of the Ranges M1 to M4
31AT02
11,50
For 3 Clamps
Page 10
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
M3
Codes
TYPES
♦
Output connections
Colour
U.P
Euros
Safety sockets Ø4 mm.
Grey
98
98
100
118
137
Safety sockets Ø4 mm.
Blue
101
Ouptut AC voltage
M1650
M2957
M3126
♦
1 mA ......200A AC
M3
M3
M3
M3.B
M3.B
200A
100A
200A
100A
10A
/
/
/
/
/
200mA
1A
1A
100mA
4mA max
Output AC voltage
M3138
M3.U
100A / 1Vac
M3139
M3.U
M3.U
200A / 0,2Vac
200A / 2Vac
M3140
M3141
M3142
M2872
M2968
M3.UB2
M3.UB2
M3.UB2
M3.UB2
M3.UB2
1A
5A
5A
5A
10A
/
/
/
/
/
1Vac
1Vac
2Vac
5Vac
1Vac
Safety sockets Ø4 mm.
Blue
178
172
M3143
M2863
M3144
M3145
M3146
M3.UB2
M3.UB2
M3.UB2
M3.UB2
M3.UB2
10A
10A
20A
20A
20A
/
/
/
/
/
2Vac
5Vac
1Vac
2Vac
5Vac
Safety sockets Ø4 mm.
Blue
172
M3147
M3148
M3149
M3150
M3151
M3152
M3153
M3.UB2
M3.UB2
M3.UB2
M3.UB2
M3.UB2
M3.UB2
M3.UB2
30A
40A
40A
40A
50A
50A
50A
/
/
/
/
/
/
/
3Vac
1Vac
2Vac
5Vac
1Vac
2Vac
5Vac
Safety sockets Ø4 mm.
Blue
172
Blue
184
200
♦
Output AC voltage, special types
M3.UB5
M3.UB5W
M3.UBxF
5A / 1Vac
5A / 1Vac
Safety sockets Ø4 mm.
.UBxF
.UB5W
♦
Please contact us
Please contact us
MIXED Output current or AC voltage.
M3154
M3.MB
300A / 300mA
30A / 3Vac
186
Safety sockets Ø4 mm.
Green
All the clamps can be designed by us in order to inject signals on cables.
Applications: Cable fault location, current flow, cables identification, ...
The CLAMPS “M3” are equiped with our patented system
anti short-circuit SIAC ®
“Special outputs”, Cables and leads with choice of the ends, see
page: 51
“Typical electrical schemes of the clamp-on current transformers - Part 1 and 2” last pages.
supplements
Other colours - Other ratios : manufactured on request, please contact us.
Page 11
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
MICROCLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Codes
M4
10 mA ......300A
TYPES
Output connections
Colour
U.P
Euros
Current output
♦
200A
100A
200A
10A
/
/
/
/
200mA
Safety sockets Ø4 mm.
1A
1A
4mA max. Safety sockets Ø4 mm.
Grey
111
Grey
153
200A
20-200A
50-100-400A
50-100-400A
/
/
/
2Vac
2Vac
1Vac
4Vac
Blue
Blue
Blue
117
208
182
1A
5A
5A
5A
10A
10A
10A
20A
20A
40A
40A
50A
50A
50A
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1Vac
1Vac
2Vac
5Vac
1Vac
2Vac
5Vac
1Vac
2Vac
2Vac
4Vac
1Vac
2Vac
5Vac
Blue
206
198
5-10-40A /
25-50-100A /
1Vac
1Vac
Safety sockets Ø4 mm.
Blue
200
5A /
5A /
1Vac
1Vac
Safety sockets Ø4 mm.
Blue
205
216
M4.V
M4.V
M4.V
200A /
200A /
50-100-200A /
1Vdc
2Vdc
1Vdc
Safety sockets Ø4 mm.
Blue
148
M
M4.VB
2Vdc
Safety sockets Ø4 mm.
Blue
188
M3177
M3178
M3179
M3180
M3181
M3182
M4.VB
M4.VB
M4.VB
M4.VB
M4.VB
M4.VB
M4.VB
20A /
40A /
50A /
100A /
40A /
50A /
100A /
25-50-100A /
1Vdc
1Vdc
1Vdc
4Vdc
5Vdc
2Vdc
1Vdc
Safety sockets Ø4 mm.
Blue
236
M3157
M3158
M3159
M4
M4
M4
M4.B
AC Current output
♦
M3183
M3184
M4.U
M4.U
M4.U
M4.U
M3161
M3162
M3163
M3164
M3165
M3166
M3167
M3168
M3169
M3170
M3171
M3172
M3173
M3174
M4.UB2
M4.UB2
M4.UB2
M4.UB2
M4.UB2
M4.UB2
M4.UB2
M4.UB2
M4.UB2
M4.UB2
M4.UB2
M4.UB2
M4.UB2
M4.UB2
M3185
M3186
M4.UB2
M4.UB2
M3160
M4.UB5
M4.UB5W
/
Safety sockets Ø4 mm.
Lead + BNC
Safety sockets Ø4 mm.
Safety sockets Ø4 mm.
Output DC voltage
♦
M3175
M3176
206
The CLAMPS “M4” are equiped with our patented system
anti short-circuit SIAC ®
“Special outputs”, Cables and leads with choice of the ends, see
page: 51
supplements
“Typical electrical schemes of the clamp-on current transformers - Part 1 and 2” last pages.
Other colours - Other ratios : manufactured on request, please contact us.
♦
Transport suitcase for Clamps of range M1 to M4
31AT02
12,50
For 3 clamps
Page 12
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Edition 1
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Codes
US
100mA.....1000A AC
TYPES
Standardized
Colour
U.P
Euros
Safety sockets Ø4 mm.
Grey
129
output connections
♦
♦
AC current output
U283
US
US
1000A / 1A
500A / 0.5A
U285
U286
U287
U288
U289
U290
U291
U292
U293
U294
US
US
US
US
US
US
US
US
US
US
100A
125A
150A
200A
250A
300A
400A
500A
600A
800A
/
/
/
/
/
/
/
/
/
/
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
Safety sockets Ø4 mm.
Grey
137
U295
U296
U297
U298
U299
U300
U301
U302
U303
U304
US
US
US
US
US
US
US
US
US
US
100A
125A
150A
200A
300A
400A
500A
600A
800A
1000A
/
/
/
/
/
/
/
/
/
/
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
Safety sockets Ø4 mm.
Grey
145
U306
U307
U308
U309
U310
U311
U312
U313
US
US
US
US
US
US
US
US
125A
150A
200A
300A
450A
600A
750A
900A
/
/
/
/
/
/
/
/
3A
3A
3A
3A
3A
3A
3A
3A
Safety sockets Ø4 mm.
Grey
147
U316
U023
U317
U318
U319
U320
U321
U322
U284
US
US
US
US
US
US
US
US
US
150A
200A
250A
300A
400A
500A
600A
800A
1000A
/
/
/
/
/
/
/
/
/
5A
5A
5A
5A
5A
5A
5A
5A
5A
Safety sockets Ø4 mm.
Grey
153
500A
600A
800A
1000A
/
/
/
/
1A
1A
1A
1A
Safety sockets Ø4 mm.
Grey
160
Output protected current
U323
U324
U325
U326
US.P
US.P
US.P
US.P
(1) Note on the “US” secondary 5A: the ratios lower than 150A/5A have been taken off of our standard range of products.
To measure weak currents, choose high ratios and an adapted reading equipment.
Exemple, clamp US 1000A/1A allow measurements from 5A to 1000A.
The connecting cables for the Current output
On the clamp itself : only our safety sockets in massive brass can insure the necessary quality for a measurment circuit
(exept for low currents or clamps especially made for some equipment).
WARNING : the linking cables do constitute a charge.
Page 13
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Codes
♦
100 mA ...... 1000A
TYPES
RATIOS
Output connections
Colour
U.P
Euros
Output multi ratios current
U338
U339
U340
U341
U342
U343
U344
U345
U346
U347
U352
U353
U354
U355
U356
U357
♦
US
(1)
US
US
US
US
US
US
US
US
US
US
100-150-200A
100-200-300A
100-200-400A
100-500-1000A
125-250-500A
150-300-600A
200-400-600A
200-400-800A
250-500-1000A
400-600-1000A
/
/
/
/
/
/
/
/
/
/
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
Safety sockets Ø4 mm.
Grey
175
US
US
US
US
US
US
125-250-500A
150-300-600A
200-400-600A
200-400-800A
250-500-1000A
400-600-1000A
/
/
/
/
/
/
5A
5A
5A
5A
5A
5A
Safety sockets Ø4 mm.
Grey
193
Blue
259
DOUBLE output current and voltage
U1307
U1308
U1309
U1310
U1311
U1312
U1313
U1314
U1315
U1316
U1317
US.D
US.D
US.D
US.D
US.D
US.D
US.D
US.D
US.D
US.D
US.D
100A
125A
150A
200A
250A
300A
400A
500A
600A
800A
1000A
/
/
/
/
/
/
/
/
/
/
/
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
Safety sockets Ø4 mm.
Options: output 1V or 2V or 3Vac . (Please contact us)
♦
DOUBLE output current and voltage (protected)
M1350
US.DP
1000A / 1A et 1Vac.
Emitting clamps
U1352
US.I
Safety sockets Ø4 mm.
Blue
for alternating current
Emitting
All the clamps can be designed in order to inject signals on cables.
Applications: Cable fault location, current flow, cables identification, ....
(1) Note on the “US” output 5A: The cables do constitut off of a charge.
The ratios lower than 150A/5A have been taken our standard pannel.
The outputs are exclusively by safety sockets. (except case of a clamp dedicated to a specific equipment).
For measuring low currents, choose high ratios and an adaptated reading equipment :
Exemple clamp US 1000A/1A allows to measure from 5A to 1000A,
Page 14
264
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
♦
RANGE
US
Codes
TYPES
100 mA ...... 1000A AC
RATIOS
Output connections
Colour
U.P
Euros
Output voltage AC.
U327
U328
U329
U330
U331
U332
U333
U334
U335
U336
U337
U025
U358
T
US.U
US.U
US.U
US.U
US.U
US.U
US.U
US.U
US.U
US.U
US.U
US.U
US.U
U1202
U1318
U1319
U1320
EP
US.UB
US.UB
US.UB
US.UB
US.UB
U1321
U1322
U1323
U1324
U1325
U1326
U1327
U1257
U857
US-UE
US-UE
US-UE
US-UE
US-UE
US-UE
US-UE
US-UE
US-UE
US-UE
100A
125A
150A
200A
250A
300A
400A
500A
600A
800A
1000A
25-50-100A
250-500-1000A
202
Safety sockets Ø4 mm.
Blue
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
266
Safety sockets Ø4 mm.
Blue
/ 1Vac
1Vac
/
Options: output 2V or 3V or 5Vac. (Please contact us).
⇒ 1A / 1Vac
225
Safety sockets Ø4 mm.
Blue
5A / 1Vac
10A / 1Vac
25A / 1Vac
295
25-50-100A / 1Vac
Options: output 2V or 3V or 5Vac. (Please contact us).
100A
125A
150A
200A
250A
300A
400A
500A
1000A
250-500-1000A
/
/
/
/
/
/
/
/
/
/
1Vac
1Vac
1Vac
1Vac
1Vac
1Vac
1Vac
1Vac
1Vac
1Vac
Safety sockets Ø4 mm-
Blue
145
209
Options: output 0,5V or 1,5V or 2Vac. (Please contact us).
WARNING : Other ratios possible but limited for reasons related to safety.
♦
Output voltage DC. Self-fed clamps. (B)
U888
U1329
U359
U360
US.V
US.V
US.V
US.V
US.VB
US.VB
US.VB
100A
1000A
25-50-100A
250-500-1000A
1Vdc
1Vdc
1Vdc
1Vdc
Safety sockets Ø4 mm.
10A / 1Vdc
50A / 5Vdc
25-50-100A / 1Vdc
Safety sockets Ø4 mm.
/
/
/
/
Blue
264
287
Blue
303
365
(B) secondary voltage output is inverted and filtered using diodes and capacitor. Please refer to electric shematics in
section 2.
V and VB extensions.
WARNING: Probes with voltage output must be connected to instruments with high impedance (>= 1 Mohm).
For any lower impedance (eg 10 kohm) please contact us.
“Special outputs”, Cables and leads with choice of the ends, see
page: 51
supplements
“Typical electrical schemes of the clamp-on current transformers - Part 1 and 2” last pages.
Others colours - Others ratios : manufactured on request, please contact us.
♦
Spare jaw protectors for US and NS types.
for 10
Page 15
13,00
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Edition 1
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Codes
♦
NS
100 mA ...... 1000A AC
TYPES
Output connections
Colour
U.P
Euros
Safety sockets Ø4 mm.
Grise
141
167
Output current.
N361
N362
NS
NS
1000A / 1A
1000A / 5A
N363
N364
N365
N366
N367
N368
N369
N370
N371
N372
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
100A
125A
150A
200A
250A
300A
400A
500A
600A
800A
/
/
/
/
/
/
/
/
/
/
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
Safety sockets Ø4 mm.
Grise
157
N373
N375
N376
N377
N378
N379
N380
N381
N382
N383
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
100A
150A
200A
250A
300A
400A
500A
600A
800A
1000A
/
/
/
/
/
/
/
/
/
/
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
Safety sockets Ø4 mm.
Grey
165
N386
N387
N388
N389
N390
N391
NS
NS
NS
NS
NS
NS
150A
200A
250A
300A
600A
900A
/
/
/
/
/
/
3A
3A
3A
3A
3A
3A
Safety sockets Ø4 mm.
Grey
171
N394
N395
N396
N397
N398
N399
N400
N401
NS
NS
NS
NS
NS
NS
NS
NS
150A
200A
250A
300A
400A
500A
600A
800A
/
/
/
/
/
/
/
/
5A
5A
5A
5A
5A
5A
5A
5A
Safety sockets Ø4 mm.
Grey
184
/
/
/
/
1A
1A
1A
1A
Safety sockets Ø4 mm.
Grey
180
Output current (protected).
♦
N402
N403
N404
N405
♦
NS.P
NS.P
NS.P
NS.P
500A
600A
800A
1000A
Transport suitcase for Clamps of the Ranges US-NS-S and SM
31AT02
13,10
For 1 clamp
Page 16
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
NS
Codes
TYPES
♦
100 mA ...... 1000A AC
Output connections
Colour
U.P
Euros
Output multi ratios current
N428
N429
N430
N431
N432
N433
N434
N435
N436
N437
N438
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
100-150-200A
100-200-300A
100-200-400A
100-500-1000A
125-250-500A
150-300-600A
200-400-600A
200-400-800A
250-500-750A
250-500-1000A
400-600-1000A
/
/
/
/
/
/
/
/
/
/
/
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
Safety sockets Ø4 mm.
Grey
198
N444
N445
N446
N447
N448
N449
NS
NS
NS
NS
NS
NS
150-300-600A
200-400-600A
200-400-800A
250-500-750A
250-500-1000A
400-600-1000A
/
/
/
/
/
/
5A
5A
5A
5A
5A
5A
Safety sockets Ø4 mm.
Grey
216
Blue
267
Blue
278
♦
Emitting clamp for alternating current.
N1356
NS.I
Emitting
All the clamps can be designed in order to inject signals on cables.
Applications: Cable fault location, current flow, cables identification, ....
♦
DOUBLE output current and voltage.
N1330
N1331
N1332
N1333
N1334
N1335
N1336
N1337
N1338
N1339
N1340
NS.D
NS.D
NS.D
NS.D
NS.D
NS.D
NS.D
NS.D
NS.D
NS.D
NS.D
100A
125A
150A
200A
250A
300A
400A
500A
600A
800A
1000A
/
/
/
/
/
/
/
/
/
/
/
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
Safety sockets Ø4 mm.
Options: output 5A - output 0,5V or 1V or 2V or 3Vac. (Please contact us).
♦
Output with protected current and voltage.
N1354
NS.DP
1000A / 1A et 1Vac
Safety sockets Ø4 mm.
Page 17
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
NS
100 mA ...... 1000A AC
TYPES
Code
Output connections
Colour
U.P
Euros
output voltage AC.
♦
N406
N407
N408
N409
N410
N411
N412
N413
N414
N415
N416
N450
N451
NS.U
NS.U
NS.U
NS.U
NS.U
NS.U
NS.U
NS.U
NS.U
NS.U
NS.U
NS.U
NS.U
100A
125A
150A
200A
250A
300A
400A
500A
600A
800A
1000A
25-50-100A
250-500-1000A
N417
N418
N419
N420
N421
N422
N423
N424
N425
NS-UE
NS-UE
NS-UE
NS-UE
NS-UE
NS-UE
NS-UE
NS-UE
NS-UE
NS-UE
100A
125A
150A
200A
250A
300A
400A
500A
1000A
250-500-1000A
/ 5Vac
Safety sockets Ø4 mm.
Blue
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 1Vac
Safety sockets Ø4 mm.
Blue
/ 1Vac
Options: output 2V or 3V or 5Vac. (Please contact us).
/
/
/
/
/
/
/
/
/
/
1Vac
1Vac
1Vac
1Vac
1Vac
1Vac
1Vac
1Vac
1Vac
1Vac
Safety sockets Ø4 mm-
Blue
216
288
162
226
Options: output 0,5V or 1,5V or 2Vac. (Please contact us).
WARNING : Other ratios possible but limited for safety reasons.
Output voltage DC .
♦
NS.V
NS.V
NS.V
NS.V
N426
N427
N452
N453
(Self-fed clamps)
100A
1000A
25-50-100A
250-500-1000A
/
/
/
/
1Vdc
1Vdc
1Vdc
1Vdc
Safety sockets Ø4 mm.
Blue
284
Safety sockets Ø4 mm.
Blue
318
“Special outputs”, Cables and leads with choice of the ends, see
page: 51
supplements
“Typical electrical schemes of the clamp-on current transformers - Part 1 and 2” last pages.
Others colours - Others ratios : manufactured on request, please contact us.
WARNING: Probes with voltage output must be connected to instruments with high impedance (>= 1 Mohm).
For any lower impedance (eg 10 kohm) please contact us.
♦
Spare jaw protectors for US and NS types
for 10
♦
13,10
Transport suitcase for Clamps of the Ranges US-NS-S and SM
31AT02
12,60
For 1 clamp
Page 18
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Codes
♦
S
TYPE
100 mA .... 1200A
RATIOS
Output connections
Colour
Safety sockets Ø4 mm.
Grey
U.P
Euros
Output current
S1006
S455
S
S
S
S.B
1000A / 0.5A
1000A / 1A
1000A / 5A
1000A / 1A
184
143
168
207
158
S458
S459
S460
S461
S462
S463
S464
S465
S466
S469
S
S
S
S
S
S
S
S
S
S
100A
125A
150A
200A
250A
300A
400A
500A
600A
800A
/
/
/
/
/
/
/
/
/
/
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
Safety sockets Ø4 mm.
Grey
S470
S471
S472
S473
S474
S475
S476
S477
S478
S479
S
S
S
S
S
S
S
S
S
S
100A
125A
150A
200A
300A
400A
500A
600A
800A
1000A
/
/
/
/
/
/
/
/
/
/
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
Safety sockets Ø4 mm.
Grey
S481
S482
S483
S484
S485
S486
S
S
S
S
S
S
125A
150A
200A
300A
600A
900A
/
/
/
/
/
/
3A
3A
3A
3A
3A
3A
Safety sockets Ø4 mm.
Grey
S489
S490
S491
S492
S493
S494
S495
S496
S
S
S
S
S
S
S
S
150A
200A
250A
300A
400A
500A
600A
800A
/
/
/
/
/
/
/
/
5A
5A
5A
5A
5A
5A
5A
5A
Safety sockets Ø4 mm.
Grey
185
/
/
/
/
1A
1A
1A
1A
Safety sockets Ø4 mm.
Grey
180
167
172
♦
Output current (protected)
S1358
S1359
S1360
S1361
S.P
S.P
S.P
S.P
500A
600A
800A
1000A
165
Page 19
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS
RANGE
Codes
♦
S
10 mA ...... 1200A
TYPE
RATIOS
AC
Output connections
Colour
U.P
Euros
Output multi ratio current
S518
S519
S521
S522
S523
S524
S525
S526
S015
S527
S528
S
S
S
S
S
S
S
S
S
S
S
100-150-200A
100-200-300A
100-500-1000A
125-250-500A
150-300-600A
200-400-600A
200-400-800A
250-500-750A
250-500-1000A
400-600-1000A
400-600-1200A
/
/
/
/
/
/
/
/
/
/
/
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
Safety sockets Ø4 mm.
Grey
200
S533
S534
S535
S536
S537
S539
S540
S
S
S
S
S
S
S
125-250-500A
150-300-600A
200-400-600A
200-400-800A
250-500-750A
400-600-1000A
400-600-1200A
/
/
/
/
/
/
/
5A
5A
5A
5A
5A
5A
5A
Safety sockets Ø4 mm.
Grey
216
Emitting clamps
for alternating current
S.I
Emitting
All the clamps can be designed by us in order to inject signals on cables.
Applications: Cable fault location, current flow, cables identification, ...
S1374
♦
DOUBLE output : simultaneous current and AC Voltage
S1362
S1363
S1364
S1365
S1366
S1367
S1368
S1369
S1370
S1371
S1372
S.D
S.D
S.D
S.D
S.D
S.D
S.D
S.D
S.D
S.D
S.D
100A
125A
150A
200A
250A
300A
400A
500A
600A
800A
1000A
/
/
/
/
/
/
/
/
/
/
/
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
Safety sockets Ø4 mm.
Blue
268
Options: output : 5A - output : 0,5V or 1V or 2V or 3V. (Please, contact us).
DOUBLE output with protected Current and Voltage
♦
S1373
♦
S.DP
1000A / 1A et 1Vac
Safety sockets Ø4 mm.
Blue
278
Spare protectors “Anti short-circuits” for the Range S
for 10
Page 20
13,00
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
10 mA ...... 1200A
TYPES
Codes
♦
S
Output connections
Colour
U.P
Euros
Output voltage AC.
S497
S498
S499
S500
S501
S502
S013
S503
S504
S505
S506
S541
S542
S1779
T
S893
S2188
S1976
S2189
EP
S507
S508
S509
S510
S511
S512
S513
S514
S028
P
P
P
P
P
P
P
P
S.U
S.U
S.U
S.U
S.U
S.U
S.U
S.U
S.U
S.U
S.U
S.U
S.U
S.U
100A
125A
150A
200A
250A
300A
400A
500A
600A
800A
1000A
25-50-100A
250-500-1000A
10-200-1000A
5Vac
Safety sockets Ø4 mm.
Blue
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
1Vac
Safety sockets Ø4 mm.
Blue
1Vac
1Vac
Options: output 2V or 3V or 5Vac. (Please contact us).
S.UB
S.UB
S.UB
S-UB
1A
5A
10A
10-100-1000A
/
/
/
/
1Vac
1 Vac
1 Vac
1 Vac
Safety sockets Ø4 mm.
S-UE
S-UE
S-UE
S-UE
S-UE
S-UE
S-UE
S-UE
S-UE
S-UE
100A
125A
150A
200A
250A
300A
400A
500A
1000A
250-500-1000A
/
/
/
/
/
/
/
/
/
/
1Vac
1Vac
1Vac
1Vac
1Vac
1Vac
1Vac
1Vac
1Vac
1Vac
Safety sockets Ø4 mm-
/
/
/
/
/
/
/
/
/
/
/
/
/
/
Blue
216
289
241
294
Blue
167
237
Options: output 0,5V or 1,5V or 2Vac. (Please contact us).
WARNING : Other ratios available but limited for safety reasons.
♦
S516
S517
S543
S544
Output voltage DC.
T
S.V
S.V
S.V
S.V
S.VB
S.VB
S.VB
Self-fed clamps
100A
1000A
25-50-100A
250-500-1000A
/
/
/
/
1Vdc
1Vdc
1Vdc
1Vdc
10A
50A
25-50-100A
/
/
/
1Vdc
5Vdc
1Vdc
Safety sockets Ø4 mm.
Blue
284
319
322
357
WARNING: Probes with voltage output must be connected to instruments with high impedance (>= 1 Mohm).
For any lower impedance (eg 10 kohm) please contact us.
“Special outputs”, Cables and leads with choice of the ends, see
page: 51
“Typical electrical schemes of the clamp-on current transformers - Part 1 and 2” last pages.
supplements
Others colours - Others ratios : manufactured on request, please contact us.
Page 21
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
1 mA ...... 1400A AC
TYPES
Codes
♦
SM
RATIOS
output connections
Colour
U.P
Euros
Output current.
SM2083
SM2084
SM2085
SM2086
SM
SM
SM
SM
1200A
1000A
1200A
1000A
/
/
/
/
1A
1A
5A
5A
Safety sockets Ø4 mm.
Grey
168
165
221
220
SM2087
SM2088
SM2089
SM2090
SM2091
SM2092
SM2093
SM2094
SM2095
SM2096
SM
SM
SM
SM
SM
SM
SM
SM
SM
SM
100A
125A
150A
200A
250A
300A
400A
500A
600A
800A
/
/
/
/
/
/
/
/
/
/
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
Safety sockets Ø4 mm.
Grey
169
SM2097
SM2098
SM2099
SM2100
SM2102
SM
SM
SM
SM
SM
100A
200A
400A
600A
1000A
/
/
/
/
/
2A
2A
2A
2A
2A
Safety sockets Ø4 mm.
Grey
174
SM2104
SM2105
SM2106
SM2107
SM
SM
SM
SM
150A
300A
600A
900A
/
/
/
/
3A
3A
3A
3A
Safety sockets Ø4 mm.
Grey
184
SM2117
SM2118
SM2119
SM2120
SM
SM
SM
SM
200A
250A
500 A
800A
/
/
/
/
5A
5A
5A
5A
Safety sockets Ø4 mm.
Grey
221
1000A / 1A
Safety sockets Ø4 mm.
Grey
323
500A
600A
800A
1000A
Safety sockets Ø4 mm.
Grey
175
PR1200X
♦
SM.B
Output current (protected).
SM2121
SM2122
SM2123
SM2124
SM.P
SM.P
SM.P
SM.P
/
/
/
/
1A
1A
1A
1A
Those CLAMPS are equiped with the patented system
anti short-circuit SIAC ®
Page 22
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
1 mA ...... 1400A AC
TYPES
Codes
♦
SM
Output connections
Colour
U.P
Euros
Output multi ratios current.
SM2153
SM2154
SM2155
SM2156
SM2157
SM2158
SM2159
SM2160
SM2161
SM2162
SM
SM
SM
SM
SM
SM
SM
SM
SM
SM
100-150-200A
100-200-400A
100-500-1000A
125-250-500A
150-300-600A
200-400-600A
200-400-800A
100-500-1000A
250-500-1000A
400-600-1200A
/
/
/
/
/
/
/
/
/
/
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
Safety sockets Ø4 mm.
Grey
211
SM2167
SM2168
SM2169
SM2170
SM2171
SM2172
SM
SM
SM
SM
SM
SM
125-250-500A / 5A
Safety sockets Ø4 mm.
150-300-600A / 5A
200-400-800A / 5A
250-500-1000A / 5A
400-600-1000A / 5A
400-600-1200A / 5A
Options: output 2A or 3A or 4A
Grey
235
NOTE: for multi ranges probes, range select is done by switching between the 4 output sockets. Therefore no
other optional output is possible for these probes.
♦
DOUBLE output current and voltage AC.
SM2134
SM2135
SM2136
SM2137
SM2138
SM2139
SM2140
SM2141
SM.D
SM.D
SM.D
SM.D
SM.D
SM.D
SM.D
SM.D
100A
200A
300A
400A
500A
600A
800A
1000A
/
/
/
/
/
/
/
/
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
Safety sockets Ø4 mm.
Blue
268
Current option: 5A output (except 100A) - Voltage output: 0,5V or 1V or 2V or 3V. (Please contact us).
♦
DOUBLE output with protected current and voltage.
SM2142
SM.DP
1000A /
1A et 1Vac Safety sockets Ø4 mm
Blue
296
Those CLAMPS are equiped with the patented system
anti short-circuit SIAC ®
Emitting clamps
for alternating current.
SM.I
SM2177
Emitting
All the clamps can be designed in order to inject signals on cables.
Applications: Cable fault location, current flow, cables identification, ....
♦
Transport suitcase for Clamps of the Ranges US-NS-S and SM
31AT02
13.00
For 1 clamp
Page 23
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
SM
1 mA ...... 1400A AC
TYPES
Codes
Output connections
Colour
U.P
Euros
Output voltage AC.
♦
SM2125
SM2127
SM2129
SM2130
SM2131
SM2133
T
SM3097
SM2174
SM2209
SM2173
SM2184
SM2185
SM2186
SM2187
SM2537
SM2457
SM2457
EP
SM2143
SM2145
SM2148
SM2149
SM2150
P
P
P
P
P
SM.U
SM.U
SM.U
SM.U
SM.U
SM.U
SM.U
SM.U
SM.U
SM.U
SM.U
SM.U
100A
200A
400A
500A
600A
1000A
100-500-1000A
125-250-500A
250-500-1000A
250-500-1000A
10-100-1000A
25-50-100A
/
/
/
/
/
/
/
/
/
/
/
/
5Vac
224
Safety sockets Ø4 mm.
Blue
5Vac
5Vac
5Vac
5Vac
5Vac
2Vac
254
Safety sockets Ø4 mm.
Blue
1Vac
5Vac
1Vac
1Vac
284
Safety sockets Ø4 mm.
Blue
1Vac
Options: output 2V or 3V or 5Vac. (Please contact us).
SM.UB
(1)
1A / 1Vac
Safety sockets Ø4 mm
SM.UB
5A / 1Vac
SM.UB
10A / 1Vac
SM.UB
25A / 1Vac
SM.UB
50A / 5Vac
SM.UB
1-100-1000A / 1Vac
Safety sockets Ø4 mm
SM.UB
2-20-200A / 2Vac
(1) 25A Max (100A-1 mn/30 mn)
Options: output 0,5V or 1V or 2V. (Please contact us).
SM-UE
100A / 1Vac
Safety sockets Ø4 mm
SM-UE
200A / 1Vac
SM-UE
400A / 1Vac
SM-UE
500A / 1Vac
SM-UE
1000A / 1Vac
SM-UE
250-500-1000A / 1Vac
Safety sockets Ø4 mm
Blue
302
276
Blue
347
Blue
203
Blue
268
Options: output 0,5V or 1,5V or 2Vac. (Please contact us).
WARNING : Other ratios available but limited for safety reasons.
Special for oscilloscope
♦
SM.UF
SM.UBF
1000A / 1Vac
1000A / 1Vac
Lead 2m with BNC
Blue
323
434
Safety sockets Ø4 mm.
Blue
296
Output voltage DC. Auto-fed.
♦
SM2151
SM2152
SM2175
SM2176
SM
SM
E
EP
EP
SM.V
SM.V
SM.V
SM.V
SM.VB
SM.VB
SM.VB
100A
1000A
25-50-100A
250-500-1000A
/ 1Vdc
/ 1Vdc
/ 1Vdc
/ 1Vdc
25A / 10Vdc
40A / 10Vdc
25-50-100A / 1Vdc
329
Safety sockets Ø4 mm.
Blue
343
Safety sockets Ø4 mm.
Blue
385
Those clamps are equiped with the Internal protection system
anti short-circuit SIAC ®
WARNING: Probes with voltage output must be connected to instruments with high impedance (>= 1 Mohm).
For any lower impedance (eg 10 kohm) please contact us.
Page 24
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Codes
E16
1A .... 1600A
TYPES
U.P
Euros
standardized output
connections
Colour
Safety sockets Ø4 mm.
Grey
264
Output current
♦
E032
E033
E034
E035
E036
E037
E038
E039
E040
E041
E042
E043
E044
E045
E16
E16
E16
E16
E16
E16
E16
E16
E16
E16
E16
E16
E16
E16
100A
125A
150A
200A
250A
300A
400A
500A
600A
800A
1000A
1200A
1250A
1500A
E046
E16
1500A / 1.5A
Safety sockets Ø4 mm.
Grey
271
E1343
E048
E049
E050
E051
E052
E053
E054
E055
E056
E057
E058
E059
E060
E16
E16
E16
E16
E16
E16
E16
E16
E16
E16
E16
E16
E16
E16
100A
125A
150A
200A
250A
300A
400A
500A
600A
800A
1000A
1200A
1250A
1500A
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
/
/
/
/
/
/
/
/
/
/
/
/
/
/
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
Safety sockets Ø4 mm.
Grey
264
/
/
/
/
1A
1A
1A
1A
Safety sockets Ø4 mm.
Grey
278
Output protected current.
♦
E16.P
E16.P
E16.P
E16.P
E061
E062
E063
E064
♦
1000A
1200A
1250A
1500A
Output multi ratios current.
E094
E095
E096
E097
E098
E026
E099
E103
E104
E105
E106
E107
E16
E16
E16
E16
E16
E16
E16
E16
E16
E16
E16
E16
100-150-200A
100-200-300A
100-200-400A
100-500-1000A
125-250-500A
150-300-600A
200-400-600A
200-400-800A
250-500-750A
250-500-1000A
400-600-1000A
500-1000-1500A
/
/
/
/
/
/
/
/
/
/
/
/
More 100 POSSIBLE COMBINATIONS
1A
Safety sockets Ø4 mm.
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
Page 25
Grey
287
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Codes
♦
E16
1A ...... 1600A
TYPES
Output connections
Colour
U.P
Euros
Grey
287
Output current. (continuation)
Mor than an 100 POSSIBLE COMBINATIONS
E108
E109
E007
E110
E031
E111
E112
E113
E021
E114
E115
E16
E16
E16
E16
E16
E16
E16
E16
E16
E16
E16
100-150-200A
100-200-300A
100-200-400A
100-500-1000A
125-250-500A
150-300-600A
200-400-800A
250-500-750A
250-500-1000A
400-600-1000A
500-1000-1500A
/
/
/
/
/
/
/
/
/
/
/
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
Safety sockets Ø4 mm.
NOTE: for multi ranges probes, range select is done by switching between the 4 output sockets. Therefore no
other optional output is possible for these probes.
♦
DOUBLE output current and voltage AC.
E16.D
100A / 1A et 5V
346
E1378
Safety sockets Ø4 mm.
Blue
E16.D
125A / 1A et 5V
E1379
E16.D
150A / 1A et 5V
E1380
E16.D
200A / 1A et 5V
E1381
E16.D
250A / 1A et 5V
E1382
E16.D
300A / 1A et 5V
E1383
E16.D
400A / 1A et 5V
E1384
E16.D
500A / 1A et 5V
E1385
E16.D
600A / 1A et 5V
E1386
E16.D
750A / 1A et 5V
E1387
E16.D
800A / 1A et 5V
E1388
E16.D
1000A / 1A et 5V
E1389
E16.D
1200A / 1A et 5V
E1390
E16.D
1250A / 1A et 5V
E1391
E16.D
1500A / 1A et 5V
E1392
Current option: 5A output (except 100A and 125A) - Voltage output: 0,5V or 1V or 2V or 3V. (Please contact us).
♦
DOUBLE output with protected current and voltage AC.
E1393
E1394
E1395
E1396
E16.DP
E16.DP
E16.DP
E16.DP
1000A / 1A et 5V
Safety sockets Ø4 mm.
1200A / 1A et 5V
1250A / 1A et 5V
1500A / 1A et 5V
Options: output: 0,5V or 1V or 2V or 3Vac. (Please contact us).
Blue
WARNING: Probes with voltage output must be connected to instruments with high impedance (>= 1 Mohm).
For any lower impedance (eg 10 kohm) please contact us.
Page 26
368
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Edition 1
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
CLAMP-ON CURRENT TRANSFORMERS AC
E16
RANGE
Codes
1A ........ 1600A AC
Output connections
TYPES
Colour
U.P
Euros
Output voltage AC.
♦
E065
E066
E067
E068
E069
E070
E071
E072
E073
E074
E075
E076
E077
E078
E116
E117
E118
E119
E120
E121
E122
E123
E124
T
E079
E080
E081
E082
E083
E084
E085
E086
E087
E088
E089
E090
P
E16.U
E16.U
E16.U
E16.U
E16.U
E16.U
E16.U
E16.U
E16.U
E16.U
E16.U
E16.U
E16.U
E16.U
E16.U
E16.U
E16.U
E16.U
E16.U
E16.U
E16.U
E16.U
E16.U
100A
125A
150A
200A
250A
300A
400A
500A
600A
800A
1000A
1200A
1250A
1500A
100-200-400A
100-250-500A
100-500-1000A
150-300-600A
200-400-800A
250-500-1000A
500-1000-1500A
250-500-1000A
500-1000-1500A
/ 5Vac
Safety sockets Ø4 mm.
Blue
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 1Vac
Safety sockets Ø4 mm.
Blue
/ 1Vac
/ 1Vac
/ 1Vac
/ 1Vac
/ 1Vac
/ 1Vac
/ 2Vac
/ 2Vac
Options: output 2V or 3V or 5Vac. (Please contact us).
E16.UE
E16.UE
E16.UE
E16.UE
E16.UE
E16.UE
E16.UE
E16.UE
E16.UE
E16.UE
E16.UE
E16.UE
E16.UE
1000A
1200A
1250A
1500A
1000A
1200A
1250A
1500A
1000A
1200A
1250A
1500A
500-1000-1500A
/
/
/
/
/
/
/
/
/
/
/
/
/
324
376
1Vac
283
Safety sockets Ø4 mm.
Blue
1Vac
1Vac
1Vac
1.5Vac
1.5Vac
1.5Vac
1.5Vac
2Vac
2Vac
2Vac
2Vac
1Vac
340
Safety sockets Ø4 mm.
Blue
Options: output 0,5V or 1,5V or 2Vac. (Please contact us).
WARNING : Other ratios possible but limited for safety reasons.
Output voltage DC.
♦
E091
E092
E093
E125
E126
E127
E128
E129
E130
T
E16.V
E16.V
E16.V
E16.V
E16.V
E16.V
E16.V
E16.V
E16.V
100A
1000A
1500A
100-200-400A
100-250-500A
250-500-1000A
250-500-1000A
500-1000-1500A
500-1000-1500A
/
/
/
/
/
/
/
/
1Vdc
1Vdc
1Vdc
1Vdc
1Vdc
1Vdc
2Vdc
1Vdc
/ 2Vdc
“Special outputs”, Cables and leads with choice of the ends, see
Safety sockets Ø4 mm.
Blue
377
page: 51
supplements
“Typical electrical schemes of the clamp-on current transformers - Part 1 and 2” last pages.
Others colours - Others ratios : manufactured on request, please contact us.
Page 27
335
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Code
♦
♦
1A ........ 1600A
Types
Output connections
Colour
U.P
Euros
Safety sockets Ø4 mm.
Grey
320
Safety sockets Ø4 mm.
Grey
325
Grey
320
Grey
342
Output current.
H132
H133
H134
H135
H136
H137
H138
H139
H140
H141
H142
H143
H144
H145
H16
H16
H16
H16
H16
H16
H16
H16
H16
H16
H16
H16
H16
H16
100A
125A
150A
200A
250A
300A
400A
500A
600A
800A
1000A
1200A
1250A
1500A
H146
H16
1500A / 1.5A
H147
H148
H149
H150
H151
H152
H153
H154
H155
H156
H157
H158
H159
H160
H16
100A / 5A
Safety sockets Ø4 mm.
H16
125A / 5A
H16
150A / 5A
H16
200A / 5A
H16
250A / 5A
H16
300A / 5A
H16
400A / 5A
H16
500A / 5A
H16
600A / 5A
H16
800A / 5A
H16
1000A / 5A
H16
1200A / 5A
H16
1250A / 5A
H16
1500A / 5A
For the CLAMPS output 5A, no other output is proposed in the standard.
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
Output current (protected).
H856
H1399
H1400
H1401
♦
H16
H16.P
H16.P
H16.P
H16.P
1000A
1200A
1250A
1500A
/
/
/
/
1A
1A
1A
1A
Safety sockets Ø4 mm.
Spare protectors “Anti short-circuits” for the Ranges E16, H16 and P16
for 10
♦
33.00
Transport suitcase for Clamps of the Ranges E16 to P32
35AT02
58,00
For 1 clamp
Page 28
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Edition 1
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Codes
♦
H16
1A ........ 1600A
Output connections
Types
Colour
U.P
Euros
Output multi ratios current.
more than 100 POSSIBLE COMBINATIONS !
H187
H188
H189
H190
H191
H192
H193
H194
H195
H196
H197
H198
H16
H16
H16
H16
H16
H16
H16
H16
H16
H16
H16
H16
100-150-200A
100-200-300A
100-200-400A
100-500-1000A
125-250-500A
150-300-600A
200-400-600A
200-400-800A
250-500-750A
250-500-1000A
400-600-1000A
500-1000-1500A
/
/
/
/
/
/
/
/
/
/
/
/
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
Safety sockets Ø4 mm.
Grey
349
H199
H200
H201
H202
H203
H204
H205
H206
H207
H208
H209
H210
H16
H16
H16
H16
H16
H16
H16
H16
H16
H16
H16
H16
100-150-200A
100-200-300A
100-200-400A
100-500-1000A
125-250-500A
150-300-600A
200-400-600A
200-400-800A
250-500-750A
250-500-1000A
400-600-1000A
500-1000-1500A
/
/
/
/
/
/
/
/
/
/
/
/
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
Safety sockets Ø4 mm.
Grey
349
H1428
H16.I
Blue
392
Emitting clamp
for alternating current.
Emitting
All the clamps can be designed in order to inject signals on cables.
Applications: Cable fault location, current flow, cables identification, ....
♦
DOUBLE output current and voltage AC.
H1402
H1403
H1404
H1405
H1406
H1407
H1408
H1409
H1410
H1411
H1412
H1413
H1414
H1415
H1416
H16.D
H16.D
H16.D
H16.D
H16.D
H16.D
H16.D
H16.D
H16.D
H16.D
H16.D
H16.D
H16.D
H16.D
H16.D
100A
125A
150A
200A
250A
300A
400A
500A
600A
750A
800A
1000A
1200A
1250A
1500A
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
Safety sockets Ø4 mm.
Options: output: 5A - output: 0,5V or 1V or 2V or 3Vac.(Please contact us).
Page 29
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
H16
RANGE
Codes
♦
Connections output
Colour
U.P
Euros
Blue
419
/ 5Vac
Safety sockets Ø4 mm.
Blue
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 5Vac
/ 1Vac
Safety sockets Ø4 mm.
Blue
/ 1Vac
/ 1Vac
/ 1Vac
/ 1Vac
/ 1Vac
/ 1Vac
/ 2Vac
/ 2Vac
Options: output 2V or 3V or 5Vac. (Please contact us).
357
TYPES
DOUBLE output with protected current and voltage AC.
H16.DP
H16.DP
H16.DP
H16.DP
H1417
H1418
H1419
H1420
♦
1A ........ 1600A
1000A / 1A et 5V
Safety sockets Ø4 mm.
1200A / 1A et 5V
1250A / 1A et 5V
1500A / 1A et 5V
Options: output: 0,5V or 1V or 2V or 3Vac.(Please contact us).
Output voltage AC.
H161
H162
H163
H164
H165
H166
H167
H168
H169
H170
H171
H172
H174
H211
H212
H213
H214
H215
H216
H217
H218
H219
T
H16.U
H16.U
H16.U
H16.U
H16.U
H16.U
H16.U
H16.U
H16.U
H16.U
H16.U
H16.U
H16.U
H16.U
H16.U
H16.U
H16.U
H16.U
H16.U
H16.U
H16.U
H16.U
100A
125A
150A
200A
250A
300A
400A
500A
600A
800A
1000A
1200A
1500A
100-200-400A
100-250-500A
100-500-1000A
150-300-600A
200-400-800A
250-500-1000A
500-1000-1500A
250-500-1000A
500-1000-1500A
426
H175
H176
H177
H178
H16.UE
H16.UE
H16.UE
H16.UE
1000A
1200A
1250A
1500A
/
/
/
/
1Vac
1Vac
1Vac
1Vac
Safety sockets Ø4 mm.
Blue
345
H179
H180
H181
H182
H16.UE
H16.UE
H16.UE
H16.UE
1000A
1200A
1250A
1500A
/
/
/
/
1.5Vac
1.5Vac
1.5Vac
1.5Vac
Safety sockets Ø4 mm.
Blue
345
H183
H184
H185
H186
H16.UE
H16.UE
H16.UE
H16.UE
H16.UE
1000A
1200A
1250A
1500A
500-1000-1500A
/
/
/
/
/
100A
1000A
1500A
100-200-400A
100-250-500A
250-500-1000A
250-500-1000A
/
/
/
/
/
/
/
4
P
♦
2Vac
345
Safety sockets Ø4 mm.
Blue
2Vac
2Vac
2Vac
1Vac
407
Safety sockets Ø4 mm.
Blue
Options: output 0,5V or 1,5V or 2Vac. (Please contact us).
WARNING : Other ratios possible but limited for safety reasons.
Output voltage DC.
H1421
H1422
H1423
H1424
H1425
H1426
H1427
EP
H16.V
H16.V
H16.V
H16.V
H16.V
H16.V
H16.V
1Vdc
1Vdc
1Vdc
1Vdc
1Vdc
1Vdc
2Vdc
Safety sockets Ø4 mm.
Blue
362
Safety sockets Ø4 mm.
Blue
438
“Special outputs”, Cables and leads with choice of the ends, see
page: 51
“Typical electrical schemes of the clamp-on current transformers - Part 1 and 2” last pages.
supplements
Others colours - Others ratios : please, contact us. Manufactured on request.
Page 30
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
♦
RANGE
P16
Code
TYPES
P562
P563
P564
P565
P566
P567
P568
P569
P570
P571
P572
P573
Colour
U.P
Euros
Safety sockets Ø4 mm.
Grey
378
Safety sockets Ø4 mm.
Grey
390
P16
150A / 5A
Safety sockets Ø4 mm.
Grey
P16
200A / 5A
P16
250A / 5A
P16
300A / 5A
P16
400A / 5A
P16
500A / 5A
P16
600A / 5A
P16
800A / 5A
P16
1000A / 5A
P16
1200A / 5A
P16
1250A / 5A
P16
1500A / 5A
For the CLAMPS output 5A, no other output is proposed in the standard options.
377
P16
P16
P16
P16
P16
P16
P16
P16
P16
P16
P16
P16
P16
P16
P16
100A
125A
150A
200A
250A
300A
400A
500A
600A
800A
1000A
1200A
1250A
1500A
1500A
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1.5A
Output protected current.
P1432
P1433
P1434
P1435
♦
Output connections
Output current AC.
P545
P546
P547
P548
P549
P550
P551
P552
P553
P554
P555
P556
P557
P558
P559
♦
1A ........ 1600A
P16.P
P16.P
P16.P
P16.P
1000A
1200A
1250A
1500A
/
/
/
/
1A
1A
1A
1A
Safety sockets Ø4 mm.
399
Spare protectors “Anti short-circuits” for the Ranges E16, H16 and P16
for 10
♦
Grey
33.00
Transport suitcase for the Clamps of the Ranges E16 to P32
35AT02
58,00
For 1 clamp
♦ Other versions, examples
E16
H16
25-50-75A/1A (dedicated clamp)
54A/1A (dedicated clamp)
Page 31
Safety sockets Ø4 mm.
Safety sockets Ø4 mm.
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Codes
♦
P16
1A ........ 1600A
Output connections
Types
Colour
U.P
Euros
Output multi ratios current.
More than an 100 POSSIBLE COMBINATIONS
P600
P601
P602
P603
P604
P605
P606
P607
P608
P609
P610
P16
P16
P16
P16
P16
P16
P16
P16
P16
P16
P16
100-150-200A
100-200-300A
100-200-400A
100-500-1000A
125-250-500A
150-300-600A
200-400-600A
200-400-800A
250-500-1000A
400-600-1000A
500-1000-1500A
/
/
/
/
/
/
/
/
/
/
/
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
Safety sockets Ø4 mm.
Grey
412
P615
P616
P617
P618
P619
P620
P621
P16
P16
P16
P16
P16
P16
P16
125-250-500A / 5A
Safety sockets Ø4 mm.
150-300-600A / 5A
200-400-600A / 5A
200-400-800A / 5A
250-500-1000A / 5A
400-600-1000A / 5A
500-1000-1500A / 5A
REMINDER, no other output options is possible
Grey
412
Blue
Safety sockets Ø4 mm.
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
Options: output: 5A - output : 0,5V or 1V or 2V or 3Vac. (Please contact us).
426
♦
Emitting clamp for alternating current.
♦
DOUBLE output current and voltage AC
P1462
P16.I
Emettrice
All the clamps can be designed in order to inject signals on cables.
Applications: Cable fault location, current flow, cables identification, ....
P1436
P1437
P1438
P1439
P1440
P1441
P1442
P1443
P1444
P1445
P1446
P1447
P1448
P1449
P1450
♦
P16.D
P16.D
P16.D
P16.D
P16.D
P16.D
P16.D
P16.D
P16.D
P16.D
P16.D
P16.D
P16.D
P16.D
P16.D
100A
125A
150A
200A
250A
300A
400A
500A
600A
750A
800A
1000A
1200A
1250A
1500A
Output protected current and voltage AC
P1451
P1452
P1453
P1454
P16.DP
P16.DP
P16.DP
P16.DP
1000A
1200A
1250A
1500A
Safety sockets Ø4 mm.
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
Options: output: 0,5V or 1V or 2V or 3Vac. (Please contact us).
Blue
WARNING: Probes with voltage output must be connected to instruments with high impedance (>= 1 Mohm).
For any lower impedance (eg 10 kohm) please contact us.
Page 32
448
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Edition 1
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Code
♦
P16
1A ........ 1600A
Output connections
Types
Colour
U.P
Euros
Output voltage AC.
P16.U
P16.U
P16.U
P16.U
P16.U
P16.U
P16.U
P16.U
P16.U
P16.U
P16.U
P16.U
P16.U
P16.U
100A
125A
150A
200A
250A
300A
400A
500A
600A
800A
1000A
1200A
1250A
1500A
P622
P623
P624
P625
P626
P627
P628
P629
P630
P16.U
P16.U
P16.U
P16.U
P16.U
P16.U
P16.U
P16.U
P16.U
100-200-400A
100-250-500A
100-500-1000A
150-300-600A
200-400-800A
250-500-1000A
500-1000-1500A
250-500-1000A
500-1000-1500A
P588
P589
P590
P591
P592
P593
P594
P595
P596
P597
P598
P599
P16-UE
P16-UE
P16-UE
P16-UE
P16-UE
P16-UE
P16-UE
P16-UE
P16-UE
P16-UE
P16-UE
P16-UE
P16-UE
1000A
1200A
1250A
1500A
1000A
1200A
1250A
1500A
1000A
1200A
1250A
1500A
500-1000-1500A
P574
P575
P576
P577
P578
P579
P580
P581
P582
P583
P584
P585
P586
P587
T
EP
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
/
/
/
/
/
/
/
/
/
/
/
/
/
/
Safety sockets Ø4 mm.
407
Blue
/ 1Vac
Safety sockets Ø4 mm.
Blue
/ 1Vac
/ 1Vac
/ 1Vac
/ 1Vac
/ 1Vac
/ 1Vac
/ 2Vac
/ 2Vac
Options: output 2V or 3V or 5Vac. (Please contact us).
487
1Vac
403
Safety sockets Ø4 mmBlue
1Vac
1Vac
1Vac
1,5Vac
1,5Vac
1,5Vac
1,5Vac
2Vac
2Vac
2Vac
2Vac
1Vac
471
Safety sockets Ø4 mmBlue
Options: output 0,5V or 1,5V or 2Vac. (Please contact us).
/
/
/
/
/
/
/
/
/
/
/
/
/
WARNING : Other ratios possible but limited for safety reasons.
♦
Output voltage DC.
P1455
P1456
P1457
P1458
P1459
P1460
P1461
P16.V
P16.V
P16.V
P16.V
P16.V
P16.V
P16.V
100A
1000A
1500A
100-200-400A
100-250-500A
250-500-1000A
250-500-1000A
/
/
/
/
/
/
/
1Vdc
1Vdc
1Vdc
1Vdc
1Vdc
1Vdc
2Vdc
“Special outputs”, Cables and leads with choice of the ends, see
Safety sockets Ø4 mm.
Blue
416
Safety sockets Ø4 mm.
Blue
499
page: 51
supplements
“Typical electrical schemes of the clamp-on current transformers - Part 1 and 2” last pages.
Others colours - Others ratios : manufactured on request, please contact us.
Page 33
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Codes
♦
1A ........ 3200A
Output connections
Colour
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
Safety sockets Ø4 mm.
Grey
259
Safety sockets Ø4 mm.
Grey
272
2000A / 2A
3000A / 3A
Safety sockets Ø4 mm.
Grey
259
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
Safety sockets Ø4 mm.
Grey
259
Safety sockets Ø4 mm.
Grey
280
/ 1A
1A
1A
1A
1A
1A
1A
Safety sockets Ø4 mm.
Grey
280
Types
U.P
Euros
Output current AC.
E631
E632
E633
E634
E635
E636
E637
E638
E639
E640
E670
E671
E672
E673
E674
E675
♦
E32
(1)
E32
E32
E32
E32
E32
E32
E32
E32
E32
E32
E32
E32
E32
E32
E32
E32
E641
E642
E32
E32
E643
E644
E645
E646
E647
E648
E649
E650
E651
E652
E676
E677
E678
E679
E680
E681
E32
E32
E32
E32
E32
E32
E32
E32
E32
E32
E32
E32
E32
E32
E32
E32
(1)
500A
600A
800A
1000A
1200A
1250A
1500A
2000A
2500A
3000A
500-1000-1500A
500-1000-2000A
500-1500-3000A
1000-1500-3000A
1000-2000-3000A
1500-2000-3000A
500A
600A
800A
1000A
1200A
1250A
1500A
2000A
2500A
3000A
500-1000-1500A
500-1000-2000A
500-1500-3000A
1000-1500-3000A
1000-2000-3000A
1500-2000-3000A
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
Output current (protected).
P1474
P1475
P1476
P1477
P1478
P1479
P1480
E32.P
E32.P
E32.P
E32.P
E32.P
E32.P
E32.P
1000A
1200A
1250A
1500A
2000A
2500A
3000A
/
/
/
/
/
/
(1) for multi ranges probes, range select is done by switching between the 4 output sockets. Therefore no other optional
output is possible for these probes. More than 100 POSSIBLE COMBINATIONS.
Page 34
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Edition 1
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Code
♦
E32
Types
1A ........ 3200A
RATIOS
Output connections
Colour
U.P
Euros
Blue
354
DOUBLE output current and voltage AC.
E32.D
E32.D
E32.D
E32.D
E32.D
E32.D
E32.D
E32.D
E32.D
E32.D
E32.D
E1481
E1482
E1483
E1484
E1485
E1486
E1487
E1488
E1489
E1490
E1491
500A
600A
750A
800A
1000A
1200A
1250A
1500A
2000A
2500A
3000A
/
/
/
/
/
/
/
/
/
/
/
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
Safety sockets Ø4 mm.
Options: output : 5A - output : 0,5V or 1V or 2V or 3Vac. (Please contact us).
♦
DOUBLE output with protected current and voltage AC.
E32.DP
E32.DP
E32.DP
E32.DP
E32.DP
E32.DP
E32.DP
Safety sockets Ø4 mm.
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
/ 1A et 5V
Options: output: 0,5V or 1V or 2V or 3Vac. (Please contact us).
E1492
E1493
E1494
E1495
E1496
E1497
E1498
1000A
1200A
1250A
1500A
2000A
2500A
3000A
“Special outputs”, Cables and leads with choice of the ends, see
page: 51
Blue
376
supplements
“Typical electrical schemes of the clamp-on current transformers - Part 1 and 2” last pages.
Others colours - Others ratios : manufactured on request, please contact us.
♦
Spare protectors “Anti short-circuits” for the Ranges E32, H32 and P32
for 10
♦
33.00
Transport suitcase for Clamps of the Ranges E16 to P32
35AT02
58,00
For 1 clamp
Page 35
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Codes
♦
E32
1A ........ 3200A
Types
Output connections
Colour
Secondaire tension AC
E32.U
E32.U
E32.U
E32.U
E32.U
E32.U
E32.U
E32.U
E32.U
E32.U
E32.U
500A
600A
750A
800A
1000A
1200A
1250A
1500A
2000A
2500A
3000A
/
/
/
/
/
/
/
/
/
/
/
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
Safety sockets Ø4 mm.
Blue
339
E682
E683
E684
E685
E686
E687
E32.U
E32.U
E32.U
E32.U
E32.U
E32.U
500-1000-1500A
500-1000-2000A
500-1500-3000A
1000-1500-3000A
1000-2000-3000A
1500-2000-3000A
/
/
/
/
/
/
1Vac
1Vac
1Vac
1Vac
1Vac
1Vac
Safety sockets Ø4 mm.
Blue
363
E688
E689
E690
E691
E962
E693
E32.U
E32.U
E32.U
E32.U
E32.U
E32.U
500-1000-1500
500-1000-2000A
500-1500-3000A
1000-1500-3000A
1000-2000-3000A
1500-2000-3000A
/
/
/
/
/
/
2Vac
2Vac
2Vac
2Vac
2Vac
2Vac
Safety sockets Ø4 mm.
Blue
363
E653
E654
E655
E656
E657
E658
E659
E660
E661
E662
E663
U.P
Euros
T
Options: output 2V or 3V or 5Vac. (Please contact us).
E664
E665
E666
E32.UE
E32.UE
E32.UE
E32.UE
1000A
2000A
3000A
1500-2000-3000A
/
/
/
/
1Vac
1Vac
1Vac
1Vac
Safety sockets Ø4 mm.
Blue
280
315
Safety sockets Ø4 mm.
Blue
Options: output 0,5V or 1,5V or 2Vac. (Please contact us).
WARNING : Other ratios possible but limited for safety reasons.
Speciale Version for leak current measurement
E32.UEB5
♦
1A / 1Vac
Safety sockets Ø4 mm.
WARNING : 50A Max. (100A~ - 1mn)
Bleue
320
Output voltage DC.
E667
E668
E669
E32.V
E32.V
E32.V
1000A /
2000A /
3000A /
1Vdc
1Vdc
1Vdc
Safety sockets Ø4 mm.
Blue
356
E694
E695
E696
E32.V
E32.V
E32.V
500-1000-2000A /
500-1500-3000A /
1000-2000-3000A /
1Vdc
1Vdc
1Vdc
Safety sockets Ø4 mm.
Blue
372
E697
E698
E699
E32.V
E32.V
E32.V
500-1000-2000A /
500-1500-3000A /
1000-2000-3000A /
2Vdc
2Vdc
2Vdc
Reminder regarding the outputs in continuous voltage (DC) : there is a constant of time.
“Special outputs”, Cables and leads with choice of the ends, see
page: 51
“Typical electrical schemes of the clamp-on current transformers - Part 1 and 2” last pages.
supplements
Others colours - Others ratios : please, contact us. Manufactured on request.
Page 36
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Codes
H32
1A ........ 3200A AC
Output connections
Types
Colour
U.P
Euros
Ø4 mm.
Ø4 mm.
Ø4 mm.
Ø4 mm.
Grey
Grey
Grey
Grey
402
469
476
336
Output current.
♦
H700
H701
H702
H703
H704
H705
H706
H707
H708
H709
H710
H32.X
H32.X
H32.B
H32
H32
H32
H32
H32
H32
H32
H32
H32
H32
H32
H711
H712
H32
H32
2000A / 2A
3000A / 3A
Safety sockets Ø4 mm.
Grey
336
H713
H714
H715
H716
H717
H718
H719
H720
H721
H722
H723
H32
H32
H32
H32
H32
H32
H32
H32
H32
H32
H32
500A
600A
750A
800A
1000A
1200A
1250A
1500A
2000A
2500A
3000A
3000A
1000A-2000A
3000A
500A
600A
750A
800A
1000A
1200A
1250A
1500A
2000A
2500A
3000A
/ 300mA
/ 200mA
/
/
/
/
/
/
/
/
/
/
/
/
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
Safety sockets
Safety sockets
Safety sockets
Safety sockets
/
/
/
/
/
/
/
/
/
/
/
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
Safety sockets Ø4 mm.
Grey
336
/
/
/
/
/
/
/
1A
1A
1A
1A
1A
1A
1A
Safety sockets Ø4 mm.
Grey
357
Output protected current.
♦
H1511
H1512
H1513
H897
H1514
H1515
H1516
♦
H32.P
H32.P
H32.P
H32.P
H32.P
H32.P
H32.P
1000A
1200A
1250A
1500A
2000A
2500A
3000A
Output Multi ratios current.
H742
H743
H744
H745
H746
H747
H32
H32
H32
H32
H32
H32
500-1000-1500A
500-1000-2000A
500-1500-3000A
1000-1500-3000A
1000-2000-3000A
1500-2000-3000A
/
/
/
/
/
/
more than 100 POSSIBLE COMBINATIONS
1A
Safety sockets Ø4 mm.
1A
1A
1A
1A
1A
H748
H749
H750
H751
H752
H753
H32
H32
H32
H32
H32
H32
500-1000-1500A
500-1000-2000A
500-1500-3000A
1000-1500-3000A
1000-2000-3000A
1500-2000-3000A
/
/
/
/
/
/
5A
5A
5A
5A
5A
5A
Page 37
Safety sockets Ø4 mm.
Grey
376
Grey
376
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Code
♦
H32
1A ........ 3200A
Types
standardized output
connections
Colour
U.P
Euros
Safety sockets Ø4 mm.
Blue
393
DOUBLE output current and voltage AC.
H32.D
H32.D
H32.D
H32.D
H32.D
H32.D
H32.D
H32.D
H32.D
H32.D
H1517
H1518
H1519
H1520
H1521
H1522
H1523
H1524
H1525
H1526
500A
600A
800A
1000A
1200A
1250A
1500A
2000A
2500A
3000A
/
/
/
/
/
/
/
/
/
/
I2 et 5V
I2 et 5V
I2 et 5V
I2 et 5V
I2 et 5V
I2 et 5V
I2 et 5V
I2 et 5V
I2 et 5V
I2 et 5V
Options output Current: 5A - output: 0,5V or 1V or 2V or 3Vac. (Please contact us).
majoration for output 5A .........
♦
DOUBLE with Protected current and voltage AC.
H1527
H1528
H1529
H1530
H1531
H1532
H1533
T
H32.DP
H32.DP
H32.DP
H32.DP
H32.DP
H32.DP
H32.DP
1000A
1200A
1250A
1500A
2000A
2500A
3000A
/
/
/
/
/
/
/
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
1A et 5V
Safety sockets Ø4 mm.
Blue
415
Options: output: 0,5V or 1V or 2V or 3Vac. (Please contact us).
“Special outputs”, Cables and leads with choice of the ends, see
page: 51
supplements
“Typical electrical schemes of the clamp-on current transformers - Part 1 and 2” last pages.
Others colours - Others ratios : manufactured on request, please contact us.
♦
Spare protectors “Anti short-circuits” for the Ranges E32, H32 and P32
for 10
♦
33.00
Transport suitcase for the Clamps of the Ranges E16 to P32
35AT02
58,00
For 1 clamp
Page 38
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Codes
♦
H32
1A ........ 3200A
Type
RATIOS
Output connections
Colour
U.P
Euros
Output voltage AC.
H754
H755
H756
H757
H758
H759
H32.U
H32.U
H32.U
H32.U
H32.U
H32.U
H32.U
H32.U
H32.U
H32.U
H32.U
H32.U
H32.U
H32.U
H32.U
H32.U
H32.U
H32.U
500A
600A
750A
800A
1000A
1200A
1250A
1500A
2000A
2500A
3000A
200A-2000A
500-1000-1500A
500-1000-2000A
500-1500-3000A
1000-1500-3000A
1000-2000-3000A
1500-2000-3000A
H760
H761
H762
H763
H764
H765
H32.U
H32.U
H32.U
H32.U
H32.U
H32.U
500-1000-1500A
500-1000-2000A
500-1500-3000A
1000-1500-3000A
1000-2000-3000A
1500-2000-3000A
H735
H736
H737
H738
H32.UE
H32.UE
H32.UE
H32.UE
H32.UE
H724
H725
H726
H727
H728
H729
H730
H731
H732
H733
H734
T
P
1000A
2000A
3000A
3000A
200-2000A
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
1Vac
1Vac
1Vac
1Vac
1Vac
1Vac
376
Safety sockets Ø4 mm.
Safety sockets Ø4 mm.
456
Blue
/ 2Vac
Safety sockets Ø4 mm.
Blue
/ 2Vac
/ 2Vac
/ 2Vac
/ 2Vac
/ 2Vac
Options: output 2V or 3V or 5Vac. (Please contact us).
457
357
/ 1Vac
Safety sockets Ø4 mm.
Blue
/ 1Vac
/ 1Vac
/ 3Vac
426
/ 2Vac
Safety sockets Ø4 mm.
Blue
Options: output 0,5V or 1,5V or 2Vac. (Please contact us).
WARNING : Other ratios available but limited due to safety issues.
♦
Speciale Version for leak current measurement
♦
Output voltage DC.
H32.UEB5
1A / 1Vac
Safety sockets Ø4 mm.
WARNING : 50A Max. (100A~ - 1mn)
Bleue
480
H739
H740
H741
H32.V
H32.V
H32.V
1000A / 1Vdc
2000A / 1Vdc
3000A / 1Vdc
Safety sockets Ø4 mm.
Blue
385
H766
H767
H768
H32.V
H32.V
H32.V
500-1000-2000A / 1Vdc
500-1500-3000A / 1Vdc
1000-2000-3000A / 1Vdc
Safety sockets Ø4 mm.
Blue
468
H769
H770
H771
H32.V
H32.V
H32.V
500-1000-2000A / 2Vdc
500-1500-3000A / 2Vdc
1000-2000-3000A / 2Vdc
H32.VB
Possible, please contact us
WARNING: Probes with voltage output must be connected to instruments with high impedance (>= 1 Mohm).
For any lower impedance (eg 10 kohm) please contact us.
“Special outputs”, Cables and leads with choice of the ends, see
page: 51
“Typical electrical schemes of the clamp-on current transformers - Part 1 and 2” last pages.
supplements
Others colours - Others ratios : manufactured on request, please contact us.
Page 39
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Codes
♦
P32
1A ........ 3200A
Type
Standardized output
connections
Colour
U.P
Euros
Output current.
P772
P773
P016
P775
P776
P777
P778
P779
P780
P821
P822
P823
P824
P825
P826
P32.X
P32.X
P32.B
P32
P32
P32
P32
P32
P32
P32
P32
P32
P32
P32
P32
P32
P32
P32
P781
P782
P32
P32
P783
P784
P785
P786
P787
P788
P789
P790
P791
P792
P827
P828
P829
P830
P131
P831
P32
P32
P32
P32
P32
P32
P32
P32
P32
P32
P32
P32
P32
P32
P32
P32
3000A
1000A-2000A
1000A
500A
600A
1000A
1200A
1250A
1500A
2000A
2500A
3000A
500-1000-1500A
500-1000-2000A
500-1500-3000A
1000-1500-3000A
1000-2000-3000A
1500-2000-3000A
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
300mA
200mA
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
2000A / 2A
3000A / 3A
500A
600A
800A
1000A
1200A
1250A
1500A
2000A
2500A
3000A
500-1000-1500A
500-1000-2000A
500-1500-3000A
1000-1500-3000A
1000-2000-3000A
1500-2000-3000A
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
5A
Ø4 mm.
Ø4 mm.
Ø4 mm.
Ø4 mm.
Grey
Grey
Grey
Grey
451
515
546
406
Safety sockets Ø4 mm.
Grey
428
Safety sockets Ø4 mm.
Grey
406
Safety sockets Ø4 mm.
Grey
406
Safety sockets Ø4 mm.
Grey
428
Grey
427
Safety sockets
Safety sockets
Safety sockets
Safety sockets
No other options for the secondary outputs
♦
Output protected current.
P1554
P1555
P1557
P1558
P1559
P1560
P32.P
P32.P
P32.P
P32.P
P32.P
P32.P
1000A
1200A
1500A
2000A
2500A
3000A
/
/
/
/
/
/
1A
1A
1A
1A
1A
1A
Page 40
Safety sockets Ø4 mm.
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Code
♦
P32
1A ........ 3200A
Output connections
Types
Colour
U.P
Euros
DOUBLE output current and voltage AC.
P32.D
P32.D
P32.D
P32.D
P32.D
P32.D
P32.D
P32.D
P32.D
P32.D
P1534
P1535
P1536
P1537
P1538
P1539
P1540
P1541
P1542
P913
500A
600A
800A
1000A
1200A
1250A
1500A
2000A
2500A
3000A
/
/
/
/
/
/
/
/
/
/
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
Safandy sockands Ø4 mm.
Blue
447
Blue
469
Options: Output: 5A - output: 0,5V or 1V or 2V or 3Vac. (Please contact us).
♦
Output protected current and voltage AC.
P32.DP
P32.DP
P32.DP
P32.DP
P32.DP
P32.DP
P32.DP
P1543
P1544
P1545
P1546
P1547
P1548
P1549
1000A
1200A
1250A
1500A
2000A
2500A
3000A
/
/
/
/
/
/
/
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
1A and 5V
Safandy sockands Ø4 mm.
Options: output: 0,5V or 1V or 2V or 3Vac. (Please contact us).
“Special outputs”, Cables and leads with choice of the ends, see
page: 51
supplements
“Typical electrical schemes of the clamp-on current transformers - Part 1 and 2” last pages.
Others colours - Others ratios : manufactured on request, please contact us.
♦
Spare protectors “Anti short-circuits” for the ranges E32, H32 and P32
for 10
♦
33.00
Transport suitcase for Clamps of the Ranges E16 to P32
35AT02
58,00
For 1 clamp
♦ Other versions, examples
P32.U
P32.U
P32.UEB
H32
P32
P32
1000-2000-8000A/1Vac - Max 8000A - 10mn/heure Safety sockets Ø4 mm.
3000A/3Vac - Max. 5000A~ 1mn
Safety sockets Ø4 mm.
1V~/A~ - 50A Max. (100A~ - 1mn)
Safety sockets Ø4 mm.
5000A 1mA~/A~ (5000A - 5mn/30mn)
Safety sockets Ø4 mm.
1000-2000A/200mA par commutateur
Cable
2000A/200mA
Safety sockets Ø4 mm.
Page 41
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT TRANSFORMERS AC
RANGE
Codes
♦
P32
1A ........ 3200A
Types
Output connections
Colour
U.P
Euros
Safety sockets Ø4 mm.
Blue
428
Safety sockets Ø4 mm.
Blue
505
Output voltage AC.
P32.U
P32.U
P32.U
P32.U
P32.U
P32.U
P32.U
P32.U
P32.U
P32.U
500A
600A
800A
1000A
1200A
1250A
1500A
2000A
2500A
3000A
/
/
/
/
/
/
/
/
/
/
P832
P833
P834
P835
P836
P837
P32.U
P32.U
P32.U
P32.U
P32.U
P32.U
500-1000-1500A
500-1000-2000A
500-1500-3000A
1000-1500-3000A
1000-2000-3000A
1500-2000-3000A
/
/
/
/
/
/
1Vac
1Vac
1Vac
1Vac
1Vac
1Vac
P838
P839
P840
P841
P842
P843
P32.U
P32.U
P32.U
P32.U
P32.U
P32.U
500-1000-1500A
500-1000-2000A
500-1500-3000A
1000-1500-3000A
1000-2000-3000A
1500-2000-3000A
/
/
/
/
/
/
2Vac
507
Safety sockets Ø4 mm.
Blue
2Vac
2Vac
2Vac
2Vac
2Vac
Options: output 2V or 3V or 5Vac. (Please contact us).
P813
P814
P815
P816
P817
P32.UE
P32.UE
P32.UE
P32.UE
P32.UE
P32.UE
1000A
2000A
3000A
2000A
3000A
1500-2000-3000A
/
/
/
/
/
/
1Vac Safety sockets Ø4 mm.
424
Blue
1Vac
1Vac
2Vac
3Vac
492
Blue
1Vac Safety sockets Ø4 mm.
Options: output 0,5V or 1,5V or 2Vac. (Please contact us).
P793
P794
P795
P796
P797
P798
P799
P800
P801
P802
T
P
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
5Vac
WARNING : Other ratios available but limited due to safety issues.
♦
Speciale Version for leak current measurement
P32.UEB5
P3337
♦
1A / 1Vac Safety sockets Ø4 mm.
WARNING : 50A Max. (100A~ - 1mn)
Bleue
614
Output voltage DC.
T
P32.V
P32.V
P32.V
1000A /
2000A /
3000A /
1Vdc
1Vdc
1Vdc
Safety sockets Ø4 mm.
Blue
438
P844
P845
P846
P32.V
P32.V
P32.V
500-1000-2000A /
500-1500-3000A /
1000-2000-3000A /
1Vdc
1Vdc
1Vdc
Safety sockets Ø4 mm.
Blue
517
P847
P848
P849
P32.V
P32.V
P32.V
500-1000-2000A /
500-1500-3000A /
1000-2000-3000A /
2Vdc
2Vdc
2Vdc
P818
P819
P820
WARNING: Probes with voltage output must be connected to instruments with high impedance (>= 1 Mohm).
For any lower impedance (eg 10 kohm) please contact us.
Page 42
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT (Hall effect)
AC-DC
This type of transducer is a converter with Hall effect element giving an analogical voltage proportional (Module, Frequency )
to the current which crosses it. The input can be AC or DC. The output is always in “voltage” .
RANGE
Codes
M926
NOTE
M2
M2.1C 01
The
RANGE
M2.2C
SC
Connection type
300A / 3 V
Cable FM 4R free ends
External supply from 9V to 18V
don’t exist anymore
Input AC, DC.
♦
♦
Euros
158
Output connections
Colour
U.P
Euros
2m of FM4R cable, free ends
Power supply and reading with 4 leads
Power supply and reading with 4 leads
Power supply and reading with 4 leads
Power supply and reading with 3 leads
Power supply and reading with 4 leads
Power supply and reading with 3 leads
Red
Red
Red
Red
Red
Red
204
232
221
244
247
271
Ø4 mm.
Ø4 mm.
Ø4 mm.
Ø4 mm.
Ø4 mm.
Red
Red
Red
Red
Red
255
259
264
315
357
Safety sockets Ø4 mm.
Safety sockets Ø4 mm.
Red
Red
340
394
Output voltage AC, DC.
External Power from 9V to 18V DC
SC.1C
SC.1C
SC.1C
SC.1C
SC.1C
SC.1C
S1791
S1792
S1169
S1183
S1199
S1000
Colour
Red
1A ........ 2000A peak
TYPES
Codes
♦
10 mA ......300A
200A
500A
1000A
1000A
1500A
1500A
/
/
/
/
/
/
1V
1V
1V
1V
1.5V
1.5V
internal Power with Battery 9V type 6LR61
S1958
S1703
S1259
S024
S1376
SC.2C
SC.2C
SC.2C
SC.3C
SC.3C
100A
200A
800A
1000A
100-1000A
/
/
/
/
/
1V
1V
800mV
1V
1V
S899
S1377
SC
SC
2000A
200-2000A
/ 2V
/ 2V
Safety sockets
Safety sockets
Safety sockets
Safety sockets
Safety sockets
Manufactured on request, the AC/DC clampls offer, with more than 30 different versions, many possibilities for
measurement.
♦
Transport suitcase for Clamps of the Range SC
32AT02
18,50
For 1 clamp
Page 43
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT (Hall effect) AC -DC
RANGE
Code
♦
H.C
± 5000A peak
Types
Output connections
U.P
Euros
Red
661
Input AC, DC. Output voltage AC, DC.
♦
H220
H221
H222
H20 .1C
H40. 1C
H50. 1C
External Power supplied with a 9 V to 12V DC
2000A / 2 V
4000A / 2 V
5000A / 2 V
♦
♦
Colour
2 m Cable FMA4R, free ends
Internal Power supplied with a 9V battery.
H223
H224
H225
H226
H20. 3C
H20. 3C
H20. 3C
H20. 3C
200-2000A
400-2000A
500-2000A
1000-2000A
2V
2V
2V
2V
Safety sockets Ø4 mm.
Red
707
H227
H228
H229
H40. 3C
H40. 3C
H40. 3C
500-4000A / 2V
1000-4000A / 2V
2000-4000A / 2V
Safety sockets Ø4 mm.
Red
902
H230
H231
H50. 3C
H50 .3C
1000-5000A / 2V
2000-5000A / 2V
Safety sockets Ø4 mm.
Red
1037
/
/
/
/
Transport suitcase for Clamps of the RANGES H.C and P.C
35AT02
58,00
For 1 clamp
Page 44
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
CLAMP-ON CURRENT (Hall effect) AC -DC
RANGE
Codes
♦
P.C
± 7500A crête
Types
Input AC-DC.
Output connections
U.P
Euros
Red
730
Ouptu voltage AC, DC.
♦
P1464
P1465
P1466
P1467
Colour
P20. 1C
P40. 1C
P50. 1C
P75. 1C
External Power supplied with a 9 V to 12V DC
2000A
4000A
5000A
7500A
♦
/
/
/
/
2V
2V
2V
1,5 V
2 m FM4R Cable, free ends
Internal Power supplied with a 9V battery.
P1468
P1469
P1470
P1019
P20. 3C
P20. 3C
P20. 3C
P20. 3C
200-2000A
400-2000A
500-2000A
1000-2000A
/
/
/
/
2V
2V
2V
2V
Safety sockets Ø4 mm.
Red
777
P1273
P1471
P898
P40. 3C
P40. 3C
P40. 3C
500-4000A
1000-4000A
2000-4000A
/ 2V
/ 2V
/ 2V
Safety sockets Ø4 mm.
Red
968
P1472
P874
P50. 3C
P50. 3C
1000-5000A
2000-5000A
/ 2V
/ 2V
Safety sockets Ø4 mm.
Red
1119
P1473
P75. 3C
7500A
and 1000A
/ 1,5V
/ 2V
Safety sockets Ø4 mm.
Red
1209
P1499
P75. 3C
7500A
and 2000A
/ 1,5V
/ 2V
P1284
P75. 3C
7500A
and 4000A
/ 1,5V
/ 2V
P1181
P75. 3C
7500A
and 5000A
/ 1,5V
/ 2V
“Special outputs”, Cables and leads with choice of the ends, see
page: 51
supplements
“Typical electrical schemes of the clamp-on current transformers - Part 1 and 2” last pages.
Others colours - Others ratios : manufactured on request, please contact us.
Page 45
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
TRANSDUCERS AC-DC
RANGE
C104
Code
Type
C1550
C104.CT- 48/2
C104.CT- 48/1
C104.CT- 24/2
C104.CT- 24/1
± 15 000A peak
Power supply
36V to
36V to
18V to
18V to
Ratio
72V DC
72V DC
36V DC
36V DC
Output type
Quantity
U.P
Euros
2306
2110
2012
1907
15 000A
10 000A
15 000A
10 000A
/
/
/
/
7.5V
10V
7.5V
10V
Screw block
Screw block
Screw block
1 to 2
3 to 5
6 to 13
14 to 21
C1119
C104.AT- 230/2
C104.AT- 230/1
C104.AT- 230/2N
C104.AT- 230/1N
230V eff. 50-60Hz
230V eff. 50-60Hz
230V eff. 50-60Hz
230V eff. 50-60Hz
15 000A
10 000A
15 000A
10 000A
/
/
/
/
7.5V
10 V
7.5V
10 V
Screw block
Screw block
BNC
BNC
1 to 2
3 to 5
6 to 13
14 to 21
2236
2021
1956
1828
C1551
C104.AS- 230/4
C104.AS- 230/5
C104.AS- 230/4N
C104.AS- 230/5N
230V eff. 50-60Hz
230V eff. 50-60Hz
230V eff. 50-60Hz
230V eff. 50-60Hz
8 000A
10 000A
8 000A
10 000A
/
/
/
/
2V
2V
2V
2V
Screw block
Screw block
BNC
BNC
1 to 2
1 to 2
1 to 2
1 to 2
1479
1849
1496
1922
This type of transducer is a converter with Hall effect elements giving an analogical voltage proportional (MODULE,
FREQUENCY) to the current that crosses it. It could replaces the shunts.
All transducers are in red stiff polycarbonate.
Manufactured on request, C104 transducers offer, with more than 50 different
versions, many possibilities for measurement.
WEIGHT AND PACKING
Type
Nett weight
Individualy packing
C104.CT
3.5 kg
440x270x310mm
1.6 kg
C104.AT
3.6 kg
440x270x310mm
1.6 kg
C104.AS
3.6 kg
440x270x310mm
1.6 kg
Page 46
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Edition 1
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
MEASUREMENT PLUGS
♦
Type
T1564
T1565
Type " PE3I"
P1053
D1586
2
1
2
3
3
Output connections
U.P
Euros
CURRENT 1 PHASE
I.cos Ø 6A eff. / 3.536V eff.
PS1ID
PS1ID
1A eff. / 5V eff.
5A eff. / 5V eff.
VOLTAGE
3 PHASES
PSTM.AC WITH continuity
PSTM.SC WITHOUT continuity
Secondary output by BNC (standard)
168
Sockets output for plug 4 ø mm.
Sockets output for plug 4 ø mm.
220
Plug counting 1 boxe
Plug “Inter-counting” 1 and 2 boxes
529
The 3 phases are protected by HPC safety fuses .
Sockets output for security plug ø 4 mm.
Sockets output for security plug ø 4 mm.
317
ACCESSORIES
Locking finger
3.90
MEASURING PLUGS for system ESSAILEC®
T1128
T1568
T1569
CURRENT
I.cos Ø
PE1ID
PE1ID
1 PHASE
6A eff. / 3.536V eff.
1A eff. / 5V eff.
5A eff. / 5V eff.
CURRENT 3 circuits
PE3ID
4 x 5A eff./0,5V à 5V eff.
CURRENT 4 circuits
PE4ID
4 x 5A eff./0,5V à 5V eff.
P1054
TENSIONS
3 PHASES
PETM.AC
Direct protected
PETM.SC
Direct protected
Secondary output by BNC (standard)
Sockets output for plugs ø 4 mm.
Sockets output for plugs ø 4 mm.
150
209
Plug counting 1 boxe
Plug “Inter-counting” 1 and 2 boxes
The 3 phases are protected by HPC safety fuses .
Sockets output for plug ø 4 mm.
446
279
SIGNALS (Voltage watching on the Meters)
S1579
S1580
S1581
S1582
♦
P1 1
Input / Output
CURRENT
3 circuits
PS3ID
4 x 5A eff./0,5V à 5V eff.
CURRENT
4 circuits
PS4ID
4 x 5A eff./0,5V à 5V eff.
♦
3
MEASUREMENT PLUGS for system SECURA®
T1127
♦
2
P2
SECURA® - ESSAILEC®
Code
1
STC
STC
STC
Manufactured on top SECURA ® fournished by the user.
Machining of the hood “not defraudable" SECURA® fournished by the user.
Manufactured on bed plate for a direct fitting on the counting table.
Non fitted (boxe alone)
See drawing N° 400227
44
6.10
52
40
Small CURRENT Transformer of Measure
T1583
TI
2500/1
Toroidal Transformer. max current 4mA
WARNING, due to the fast, increase of components prices, some of these prices can be updated.
Please contact us for confirmation.
Page 47
49
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Edition 1
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
CALIBRATION CERTIFICATE (BNM connected)
MONO RATIO AC
Clamp
Type
M1
M2
M3
M4
US
NS
S
SM
E16/E32
H16/H32
P16/P32
Fixe
Cost
Euros
the point
Nomber
of points
(in standard)
With the fixe cost :
Euros
9,70
5,90
3 points
27,40
19,30
7,80
4 points
50,50
38,50
7,80
4 points
69,70
SINGLE RATIO and MULTI RATIO AC/DC
SC.3C
19,30
6,00
4 in AC/caliber
&
4 in DC/caliber
67,30
HC/PC
47,70
6,00
3 in AC/caliber
&
3 in DC/caliber
83,70
TRANDUCER
76,00
7.80
7 in DC/caliber
+/-
130,60
TRI RATIO AC
M2
M4
US
NS
S
SM
E16/E32
H16/H32
P16/P32
9,70
5,20
9 points
(3 by caliber)
56,50
9 points
(3 by caliber)
19,30
5,20
39,70
6,00
66,10
12 points
(4 by caliber)
111,70
This table summarizes the most usual requests. We can answer any particular request on the calibrations. Please precise
the real using conditions and environment. This can lead to dedicate a CLAMP to an equipement or to a particular
application. In this case, the standard CEI 61010-2-032 foresses a special marking of the CLAMP.
WARNING : a calibration is always done with a well defined impedance called rated burden. This is measured at the
“OUTPUTS” of the clamp, the Sockets or the extremities of the leads or of the linking cables if they are bounded up with
the CLAMP.
One should always consider the influence of the linking elements on the charge or on the accuracy power.
Page 48
Universal Technic
PARIS - FRANCE Tel: (33-1) 43 70 08 00 - FAX: (33-1) 43 48 44 07
TYPICAL ELECTRIC SCHEMES of the CLAMP-ON CURRENT TRANSORMERS - Part 1
Measuring ALTERNATIVE CURRENT from 40Hz to some kHz
Output in CURRENT
“Treatments” schemes
AC
EXTENSIONS
-
Explanations
SINGLE RATIO (str01)
To supply a large variety of measuring equipements in alternative
currents : ammmeters , wattmeters , recorders , meters , etc... This is the
Whitout most traditional duty of the CLAMPS.
To measure POWERS, you must choose the clamps and ranges able to
deliver an accurate power between the classes 0,5 and 1. Only those
classes guarantee a limit in the phase shift.
P1
S1
Is
S2
P2
MULTI RATIOS (ta02)
P1
Same as the Single Ratio.
The switching of the ranges is made by selection of the 4 Socket outputs of
Whitout the Clamp :
1 socket marked “S1-0” (common).
3 sockets “S2” marked with the value of the ranges.
Exemple: S1-0 250A 500A
1000A
ALWAIS Open the clamp before switching ranges.
Is
P2
SINGLE RATIO PROTECTED (sta03)
.P
If an output circuit is inadvertendly opened (infinite impedance), an high
level voltage does appear at the bounds of the clamp. To protect the
operator and the instruments, a mechanism of limitation of voltage equip
those clamps without reducing their accuracy.
This mechanism is only useful for the ratios of high transformer ratio,
usually > 500.
.L
To insure the protection of some equipements,
the voltage is limited to 1.2V
Note : This mechanism does not alter the accuracy below 1.2V.
P1
Is
P2
LIMITATION of output Voltage
P1
Is
P2
HIGH TRANSFORMER RATIOS
P1
is
.X
.XB
Signal of output in mA. (Max. 4mA)
The “B” extension means “Special LOW CURRENT” on the input.
The magnetic circuit of the clamps having this extension is made out of
very high permeability materials (Iron-Nickel).
P2
DOUBLE Ouptut - 2 simultaneous output : CURRENT+VOLTAGE AC
SINGLE RATIO
S1
Us
.D
P1
Is
(td01)
To use successively or simultaneously equipments on high and low input
impedances.
Exemple: the current output is bounded to a Wattmeter and the voltage
output to a voltmeter to know the power value of the current.
S1
Note: for Voltage output only, short the current output with a standard
measuring lead, as short as possible.
P2
SINGLE RATIO, PROTECTED
S1
Us
.DP
P1
Is
S1
The CLAMP is Protected in case of accidental opening of its
circuit output in current.
The output in voltage is, kept at low potential.
P2
Mixed Output
1 output in alternance
Current or Voltage
P1
Is
Possible to manufacture in some cases
Us
.MB
P2
...\..\WUT-DTG\W121-SCHE-F01.PUB-97+SCHxxx.CLP-Niveau : 4.1.2-Decembre 2008
Imprimé par UNIVERSAL TECHNIC le jeudi 5 juillet 2012
Universal Technic
PARIS - FRANCE Télép: (33-1) 43 70 08 00 - FAX: (33-1) 43 48 44 07
ELECTRICAL SCHEMES of the CLAMP-ON CURRENT TRANSFORMERS - Part 2
secondary OUTPUT in VOLTAGE AC
“Treatments” Schemes
EXTENSIONS
-
SINGLE RATIO
P1
S1
-UE
-UB
Us
S2
P2
TRI RATIOS
P1
-UE
-UB
P2
SINGLE RATIO
P1
.U
.UB
P2
Explanations
GENERALITIES
To convert directly in the CLAMP, the current to measure to a Voltage
allowing :
- to considerably rise up the measuring dynamic of the primary current
Ip (> 100)
- to exclude the worry of the charge of the linking cables of the outputs
in current.
- to enter without interface on the high impedances of the electronic
appliances the most sofisticated (oscilloscopes , acquisitions chains ,
dataloger , etc...)
- to be, assuming this principle, auto protected in case of accidental
opening of the secondary circuit.
Notes :
- You must take into account the eventual perturbation of a very low
voltage on high impedances.
- It is important to respect the minimal impedance of the reading
appliance or to indicate it to allow a special calibration.
The U extensions . The intermediate transformer (TI) allows :
a good impedance adaptation
- overload most of the time without consequence,
- a possible output voltage up to 5Vrms.
- a weak thermic drift (very low power at the TI output).
The UE extensions. The manufacturing is simplified, but presents
limits, reasons:
- A protection against the overloads is often necessary (by diodes)
which limits to 3Vrms max the possible output voltage.
TRI RATIOS
P1
.U
.UB
The “B” extension means “Special LOW CURRENT” on the input.
The magnetic circuit of the clamps, having this extension, is made out of
very high permeability materials (Iron-Nickel).
P2
Secondary output in VOLTAGE DC
SINGLE RATIO
P1
.V
.VB
P2
TRI RATIOS
P1
.V
.VB
This clamps are equiped with an internal analog converter to 1 or 3 ratios
Current AC / Voltage DC supplied by the CLAMP.
This is a very straight design to convert an alternative current to a
continuous Voltage.
Having continuous voltage output allows to enter, without interface, on the
high impedances of the electronic measuring appliances which don’t have
an alternative range.
However, you must take into account :
- that the output signal is presents residual ondulation,
- that the “phase” information doesn’t exist anymore.
- the presence of a time constant fonction of the RC circuit RC of the
clamp and of the measuring appliance.
This clamp don’t replace entirely the output clamp in AC voltage.
P2
Measuring of the CONTINUOUS & ALTERNATIVES currents (HALL Effect), Output : TENSION AC /DC
EXTERNAL supply (9 to 15V)
There are also versions with 3 leads (please contact us)
P1
Us
.1C
For special applications.
This clamps are mostly destined to OEM.
You must fournish an outside supply in continuous voltage, without
undulation.
P2
INTERNAL supply Battery 9V
This clamps are entirely autonomous.
P1
Us
P2
...\..\WUT-DTG\W122-SCHE-F01.PUB-97+SCHxxx.CLP-Niveau : 4.1.2-Decembre 2008
.2C
.3C
Note :
If the input current is AC, the output voltage is AC .
The reading appliance must be of the “Amperemeter” type.
If the input is DC, the output voltage is DC .
The reading appliance must be of the “Voltmeter” type.
This principle reproduces in output an image of the input current.
Universal Technic PARIS - FRANCE -Tél:(33) 01 43 700 800 - FAX:(33) 01 43 48 44 07- Email : lut@fluke.com
PRICE LIST 2012
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
Edition 1
U.P
Euros
Connections, Options, Special outputs
♦
Connectic on the clamp (in handle output)
Reminder : all the clamps are equiped in standard with safety sockets of 4mm.
For the multi ratio clamps and secondary in Current, only those sockets are usable.
Socket D01 warning 150V CAT III max
Metalic BNC , BNC plastic, Sockets for JUPITER plug, Sockets JACK type plugs, etc..
♦
Cables connected to the clamps
Shielded cable FM2R of 2 m with free extremity
9,60
Shielded cable FM2R of 2 m ended with a FRB D01 3 pins connector
22.20
Shielded cable FM2R of 2 m ended with a FRB D01 4 pins connector
28.60
Shielded cable FM2R of 2 m ended with a DIN Plastic 5, 6 or 8 Pins connector
Shielded cable FM2R
other lenghts
surcharge by meter
28.60
Shielded cable FM4R of 2m with free extremity
12,80
Shielded cable FM4R of 2m ended with a FRB D01 3 pins connector
30,80
Shielded cable FM4R of 2m ended with a FRB D01 4 pins connector
37,20
Shielded cable FM4R of 0.5m ended with a FRB D01 3 pins connector
Cable FM 4R
other lenghts
surcharge by meter
23,40
Cable GRTH, (2x0.93mm²), de 2 m free extremity
13,80
Cable GRTH, (2x0.93mm² )
other lenghts
surcharge by meter
2.20
3,20
2,30
Bifilar cable (2x0.75 mm²) 2 m with free extremity
4,20
Bifilar cable (2x0.75 mm²) of 2m + connector 2 security plugs Red/Black ø 4mm.
11,60
Bifilar cable (2x0.75 mm²) of 4m + connector 2 security plugs Red/Black ø 4mm.
Bifilar Cable (2x0.75 mm²) other lenghts
surcharge by meter
24,40
1,20
NOTE: For shorter cables, there is no reduction (compensed by the fixe expenses).
♦
Cable in Spiral of 2 m ended with a CPR 1000 connector
29,70
Cable in Spiral of 3 m ended with a CPR 1000 connector
32,90
Cable in Spiral of 4,5 m (5x0.1) ended with free extremity
19,10
Shield coaxial cable, Black, RG58 of 2 m long, ended with a BNC connector
25,40
Shield coaxial cable, Black, RG58 of 5 m long, ended with a BNC connector
48,80
Shield coaxial cable, Black, 7045IEC of 2.5 m long, ended with a BNC connector
28,60
Accessory cables
Bifilar cable ADAPTATOR of 2 m Connector FRB D01 (3 pins)/ security plug ø 4 mm.
♦
♦
34,00
16,00
Set of 2 cables of 2 meters with security plugs ø 4 mm (1 red - 1 black)
Special connectors ending the Cables
Special cables following specifications or fournished by the customer
NOTE : WARNING, the Cables and the connectic must be compatible with the nature of the secondary signal,
“Current : <1A,... 5A” ou “Voltage” and “Frequency” .
WEIGHT AND PACKING
Type Nett weight
M1
0.110 Kg
M1
0.130 Kg
M2
0.120 Kg
M2
0.140 Kg
US
0.500 Kg
NS
0.590 Kg
S
0.620 Kg
SM
0.600 Kg
SC
0.800 Kg
E16
H16
P16
E32
H32
P32
1.9 Kg
2.0 Kg
2.2 Kg
1.4 Kg
1.6 Kg
1.8 Kg
Individualy packing
185x70x22 mm
155x95x22 mm
185x70x22 mm
155x95x22 mm
215x110x50 mm
215x110x50 mm
215x110x50 mm
215x110x50 mm
Mallette
10 g
15 g
10 g
15 g
50 g
50 g
50 g
50 g
360x180x75 mm
360x180x75 mm
360x180x75 mm
360x180x75 mm
360x180x75 mm
360x180x75 mm
210 g
210 g
210 g
210 g
210 g
210 g
sockets output
cable output
sockets output
cable output
Carboard box:
1 Clamp
3 Clamps
6 Clamps
Page 51
Transport packing
following quantity
following quantity
following quantity
following quantity
following quantity
following quantity
following quantity
following quantity
following quantity
Dimensions (mm).
440x250x150
440x250x310
440x250x560
Weight (g).
950
1500
2350
Universal Technic PARIS - FRANCE -Tel: (33) 01 43 700 800-FAX: (33) 01 43 48 44 07- Email: lut@fluke.com
PRICE LIST 2012
Edition 1
Valid on and after 1 June 2012.
Cancel the price list 1 May 2008
CONDITIONS GENERALES DE VENTES
1- GENERALITES.
Pour les professionnels, les commerçants, les sociétés et les particuliers toute commande comporte de plein droit acceptation des
conditions générales suivantes et, le cas échéant, des conditions particulières précisées au moment de la commande.
Nos conditions ne peuvent en aucun cas être modifiées ou annulées par des dispositions contraires stipulées par les acheteurs, sans
accord écrit de notre part.
Les offres sont valables dans la limite du délai d’option qui sauf stipulation contraire est d’un mois à dater de la remise de l’offre.
Les renseignements portés sur les catalogues, notices, barèmes, ne sont donnés qu’à titre indicatif, nous nous réservons le droit de les
modifier à tout moment sans préavis.
2- PRIX.
Nos prix répondent aux conditions de tarification en usage le jour de la livraison, et s’entendent hors taxes en euros pour tout matériel non
emballé, départ de notre centre de production Parisien.
3- LIVRAISON - EXPEDITION.
L’expédition, en FRANCE ou à L’EXPORTATION, de nos matériels est effectuée:
Par transporteur pour toutes livraisons .
Les coûts d’emballage et de transport seront facturés en sus.
4- GARANTIES - MODIFICATIONS.
Nous accordons à tous nos produits une garantie de 2 ans à partir de la date de facture, celle-ci tenant lieu de bon de garantie. Elle
s’entend pièces et main d’oeuvre, sauf indications contraires précisées sur nos documents.
Elle exclut les conséquences de l’usure normale, du mauvais usage ou du défaut d’entretien.
Réparation hors période de garantie: les matériels réparés bénéficient d’une garantie supplémentaire sur les pièces remplacées pendant
une durée de 1 mois.
Notre Service Après-Vente vous apporte l’assistance nécessaire bien au-delà de la période de garantie.
Des modifications liées à l’évolution technique peuvent être apportées pour améliorer les produits.
Les modèles du catalogue, les caractéristiques et les spécifications sont ainsi sujets à changement, sans préavis.
5- CONDITIONS DE PAIEMENT.
Sauf indication expresse portée sur la facture, le paiement s’entend:
première affaire: Règlement comptant à réception de facture.
Affaires suivantes et après ouverture de compte: Crédit maximum 30 jours nets.
Mode de règlement par chèque ou virement bancaire à convenir.
5.1- RETARD DE PAIEMENT.
Le non paiement d'une fraction de prix à son échéance entraînera de plein droit et sans mise en demeure des intérêts applicables sur les
sommes dues à un taux égal à une fois et demie le taux de l'intérêt légal.
6- DEFAUT DE PAIEMENT.
Le défaut de paiement de l’une des quelconques échéances pourra entraîner la revendication de ces marchandises.
L’acheteur assume, à compter de la livraison, les risques de perte ou de détérioration de ces biens, ainsi que la responsabilité des
dommages qu’ils pourraient occasionner.
7- RESERVE DE PROPRIETE.
Notre société conserve la propriété des matériels livrés, jusqu’au paiement complet de l’intégralité de la facture.
8- RECLAMATIONS - RETOURS.
Toute réclamation doit être formulée dans un délai de huit jours francs après réception des produits.
Tout retour ou reprise ne peut se faire sans notre accord préalable et pour des produits livrés depuis un mois au plus, restitués dans leur
emballage d’origine et en parfait état.
Les produits ne devront avoir subi aucune modification ou altération.
Les retours en port dû seront refusés.
9- INFRACTION aux BREVETS ou MODELES DEPOSES
L’acheteur s’engage d’avance à nous dédommager de tous frais et pénalités auxquels nous serions exposés du fait de réalisations
effectuées suivant spécifications de l’acheteur et qui se trouveraient en infraction avec des brevets ou modèles déposés, ou tout autre
protection de fait.
10- CONTESTATION - JURIDICTION.
En cas de contestation de tout ou partie des présentes conditions de vente comme pour toutes celles pouvant naître de l’exécution d’une
quelconque commande, le tribunal de commerce de Paris est seul compétent.
Pour les produits destinés à l’exportation, la Loi applicable est la Loi Française.
Page 52
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising