Data sheet
MX460−P
Rugged frequency
measuring amplifier
Special features
− 4 individually configurable inputs
(electrically isolated)
− Connection of digital signals: up
to 1 MHz
− Data rate: up to 96,000 Hz
− Bandwidth 39 kHz
− Active low pass filter
− Real-time computation (on-board)
Peak, vibration analysis,
differential angle
− TEDS support
− Supply voltage (DC) for active
transducers: 5 V ... 24 V
Block diagram
Digital platform
Ethernet
TEDS
.
.
.
.
.
Connectors 1...4
FireWire
AC
3x RS485
TEDS
B3510-1.0 en
Electrical
isolation
Transducer supply
MUX
(multiplexer)
Connecting sockets (ODU)
3x RS485
Electrical
isolation
AC
MUX
(multiplexer)
Transducer supply
FireWire
Specifications MX460−P
General specifications
Inputs
Number
4, electrically isolated from each other
Torque transducers, frequencies in general, counters,
rotary encoders, incremental encoders, pulse encoders,
shaft encoders (digital, sinusoidal, with/without index)
Transducer technologies
Data rate
Bandwidth
Hz
Time domain
Frequency/Spectrum analysis
Transducer identification (TEDS, IEEE 1451.4)
kHz
kHz
approx. 10
38
max. TEDS module distance
Transducer connection
m
100
ODU
Supply voltage range (DC)
Supply voltage interruption
Power consumption
V
10 ... 30, nominal (rated) voltage 24 V
max. for 5 ms at 24 V
without adjustable transducer excitation
with adjustable transducer excitation
Transducer excitation (active transducers)
W
W
<6
<9
V
W
5 ... 24; adjustable channel by channel
0.7 per channel / 2 in total
−
−
10Base-T / 100Base-TX
TCP/IP (direct IP address or DHCP)
ODU with twisted pair cable (CAT-5)
m
100
MBaud
A
IEEE 1394b
400 (approx. 50 MBytes/s)
1.5
m
−
5
12 (= 11 hops)
Adjustable voltage (DC)
Maximum output power
Ethernet (data link)
Protocol/addressing
Plug connection
Max. cable length to module
FireWire (module synchronization, data link, optional
voltage supply)
Baud rate
Max. current from module to module
Max. cable length between nodes
Max. number of modules connected in series (daisy
chain)
Max. number of modules in a FireWire system (incl.
hubs1), backplane)
chain2)
Max. hops in a
Synchronization options
EtherCAT
NTP
IRIG−B (B000 bis B007; B120 bis B127)
−
0.1 ... 96000 per channel, adjustable individually
24
−
14
FireWire (automatically, recommended)
via CX27
via Ethernet
via MX440A- or MX840A input channel
Nominal (rated) temperature range
Operating temperature range
C [F]
C [F]
−20 ... +60 [−4 ... +140]
−35 ... +80 [−31 ... +176]
Storage temperature range
Relative humidity
Protection class
C [F]
%
−40 ... +85 [−40 ... +185]
5 ... 95 (non-condensing)
III
IP20 per EN60529
EN61326
Degree of protection
EMC requirements
Mechanical tests3)
Vibration (30 min)
Shock (6 ms)
m/s2
m/s2
Dimensions, horizontal (H x W x D)
mm
50
350
52.5 x 200 x 122 (with case protection)
44 x 174 x 119 (without case protection)
Weight, approx.
g
2000
1)
Hub: FireWire node point or distributor
Hop: transition from module to module/signal conditioning
3) Mechanical stress is tested according to European Standard EN60068−2−6 for vibrations and EN60068−2−27 for shock. The equipment is subjected to an
acceleration of 50 m/s2 in a frequency range of 5...65 Hz in all 3 axes. Duration of this vibration test: 30min per axis. The shock test is performed with a nominal
acceleration of 350 m/s2 for 6 ms, half sine pulse shape, with 3 shocks in each of the 6 possible directions.
2)
HBM
2
B3510-1.0 en
Specifications MX460−P (continued)
Transducer technology Technical Data
0.01
Accuracy class
Transducers that can be connected
RS485 inputs
torque transducers, incremental encoders, frequency signal
sources (square1-wave)
AC input
Input frequency range
RS485 inputs
AC input
passive inductive speed sensors, frequency signal sources
(any signal shape)
Hz
Hz
0.1 ... 1 000 000
10 ... 50000
Measuring ranges frequency measurement
kHz
20; 200; 1000
Resolution frequency measurement, min.
mHz
Measuring range 20 kHz
1 (signal range: 0.1 ... 8192 Hz)
2 (signal range: 8193 ... 16384 Hz)
4 (signal range: 16385 ... 32768 Hz)
Measuring range 200 kHz
10 (signal range: 0.1 ... 65536 Hz)
16 (signal range: 65537 ... 131072 Hz)
32 (signal range: 131073 ... 262144 Hz)
Measuring range 1000 kHz
Square-wave signal measurement (RS485 inputs)
F1 (+/−)
F2 (+/−)
Zero index (+/−)
Input level (RS485 inputs) for single-pole mode
Source at signal (+) and ground, signal (−) connected to
Vref (Pin 9 DSUB, Pin 4 ODU)
Low level
High level
125 (signal range: 0.1 ... 1048576 Hz)
Quadrature signals with index
Frequency or pulse signals
Directional signal offset by 90o to F1
Zero position signal
V
V
< 2.3
> 2.7
mV
mV
signal (+) < signal (−) −200
signal (+) < signal (−) −50
V
V
−7 ... +12
"40
V
V
V
V
0.1 (to 1 kHz)
1 (at 10 kHz)
5 (at 50 kHz)
40
Input impedance
RS485 inputs
connectable termination resistor RS485 inputs
AC input
kW
W
kW
> 45
125
> 100
Frequency measurement
Frequency (RS485 inputs)
Frequency (AC inputs)
Hz
Hz
10 ... 1 000 000
10 ... 50 000
Counter (RS485 inputs)
Frequency
Increments
Hz
−
0 ... 1 000 000
"2000000
Input level (RS485 inputs) for differential signal mode
Push-pull signal at signal (+) and signal (−)
Low level
High level
Input voltage range (RS485 inputs)
Common-mode voltage range (to ground)
max. permissible voltages (to ground)
Input level for AC input (F1) (peak to peak)
minimum level
maximum level
B3510-1.0 en
3
HBM
Specifications MX460−P (continued)
Pulse-width modulated signals (PWM)
Frequency
Pulse width/duty ratio
Hz
%
0.1 ... 100 000
5 ... 95
Pulse duration/High-level or Low-level duration
ms
0 ... 5 000
Period duration
ms
0 ... 5 000
Internal sampling frequency
Glitch filter time constant (adjustable)
Permissible cable length between MX460 and
transducer
MHz
98.3
s
0.1; 1; 10; 100
m
100
Measurement frequency range (−1 dB)
kHz
0 ... 20
Active low pass filter (Bessel/Butterworth adjustable)
Hz
0.01 ... 10 000, Filter off
Frequency measurement deviation
%
< 0.01 of measured value
PWM deviation
Pulse duration deviation
Periodic time deviation
%/kHz
0.3
ns
500
ns
200
Zero drift
% / 10 K
0
Full scale drift
% / 10 K
< 0.01 of measured value
Hz
Hz
8
96000
96000
Hz
Hz
96000
96000
Hz
Hz
96000
96000
Real-time computation on the module
Peak-value unit
Number of peak values
Max. update rate
Max. output rate
Analysis functions
Differential angle
Max. update rate
Max. output rate
Torsional vibration analysis
(differential angle to uniform angular velocity)
Max. update rate
Max. output rate
HBM
4
B3510-1.0 en
Active low-pass filter data MX460−P
(4th order Bessel/Butterworth with data rate < 96000 Hz; 6th order with data rate = 96000 Hz)
Type
Bessel
Butterworth
B3510-1.0 en
−20dB
(Hz)
Phase delay*)
(ms)
−1dB
(Hz)
−3dB
(Hz)
Rise time
(ms)
Overshoot
(%)
Data rate
(Hz)
20000
29250
43000
0.002
0.016
4.1
96000
10000
16810
40260
0.008
0.023
1.5
96000
5000
8510
19906
0.027
0.042
0.9
96000
2000
3515
8275
0.094
0.1
0.6
96000
1000
1715
4070
0.22
0.2
0.6
96000
500
852
2008
0.47
0.41
0.6
96000
200
341
803
1.22
1.01
0.8
96000
100
50
171
84.2
402
215
2.5
4
2.01
4.08
0.8
1
96000
19200
20
33.7
86
10
10.2
1
9600
10
16.9
43
20
20.6
1
9600
5
8.41
21.5
40
41
1
4800
2
3.37
8.6
98
102.8
1
1200
1
1.68
4.3
196
206.4
1
600
0.5
0.84
2.15
392
411.2
1
600
0.2
0.34
0.86
982
1026
1
300
0.1
0.17
0.43
1968
2052
1
150
20000
21700
27500
0.025
0.02
15.6
96000
10000
11100
15500
0.06
0.04
15.6
96000
5000
5585
8100
0.13
0.08
14.5
96000
2000
2238
3280
0.3
0.2
14.5
96000
1000
1119
1640
0.6
0.4
14.5
96000
500
560
820
1.2
0.8
14.5
96000
200
237
420
2.1
1.6
11
19200
100
50
118
59
210
105
4
7.8
3.3
6.6
11
11
19200
19200
20
24
42
19.4
16.1
11
4800
10
11.8
21
38.6
32.4
11
2400
5
5.9
10.5
76.6
65
11
1200
2
2.4
4.2
191
163
11
600
1
1.2
2.1
382
325
11
300
0.5
0.59
1.05
760
653
11
300
0.2
0.24
0.42
1900
1630
11
150
0.1
0.12
0.21
3790
3260
11
150
5
HBM
Accessories, to be ordered separately
MX460−P accessories
Article
Description
Order no.
AC−DC power supply (24 V, ODU IP68)
Input: 90...264V~, 1.5 m cable + internat. plugs;
Output: 24V=, max. 1.25 A, 2 m cable with ODU−IP68.
1−NTX002
Cable power supply (ODU−IP68, 5 m)
Power supply cable for P modules; length 5 m. Suitable plug
(ODU, IP68) at one end, open stranded wires at the other
end.
1−KAB294−5
Connector power supply (ODU−IP68, 4 pin)
Push−in connector, ODU, IP68. For voltage supply of
QuantumX modules with IP67 protection.
1−CON−P1001
Ethernet (modul to PC, ODU−IP68, RJ45, 5 m)
Ethernet patch cable from PC to QuantumX module, IP68,
length: 5 m;
with matching plugs on both sides (RJ45 at PC end, ODU at
module end).
1−KAB273−5
Ethernet (ODU−IP68, M12, 5 m)
Ethernet patch cable from PC to QuantumX module, IP68,
length: 5 m;
with matching plugs on both sides (M12 at PC end, ODU at
module end).
1−KAB295−5
FireWire (modul to modul, IP68)
FireWire cable connector between QuantumX modules, fitted
with suitable plugs at both ends.
Lengts 0.2 m/2 m/5 m.
Note: modules can be supplied with power over this cable
(max. 1.5 A, from the source to the last drain).
1−KAB272−0.2
1−KAB272−2
1−KAB272−5
FireWire IEEE PC−Card
FireWire IEEE 1394b PC−Card (PCMCIA adapter) to connect
QuantumX modules to a Notebook or a PC.
1−IF001
FireWire (modul to PC, IP68, 5 m)
FireWire cable connector from PC to first module. For data
transmission from QuantumX modules to PC. Fitted with
suitable plugs at both ends. Length: 5 m.
Note: modules can not be supplied with power over this
cable.
1−KAB293−5
FireWire (modul to Hub, ODU−IP68, 3 m)
FireWire connection cable from hub to first module with IP68
protection For data transfer from QuantumX modules to the
PC. Fitted with suitable plugs at both ends. Length: 3 m.
Note: modules can be powered over this cable (max. 1.5 A,
from source to the last drain).
1−KAB276−3
FireWire-Extender
SCM-FireWire-Extender, IP68
Package consists of 2 In−line elements to extend the FireWire
connection up to 50 m; Necessary parts: 2 x 1−KAB269−x
and Industrial Ethernet cable (M12, CAT5e/6, max. 50 m).
KAB270−3 connection is not possible!
1−SCM−FW
Connector sensor (ODU−IP68, 14 Pin)
10 push−in connectors, ODU, IP68. For sensor connection.
1−CON−P1007
Connector sensor (ODU−IP68, 8 Pin)
10 push−in connectors, ODU, IP68. For sensor connection.
1−CON−P1006
Connecting elements
4 elements for mechanically connecting ultra-rugged modules
1−CASELINK
Carrying handle
Foldable carrying handle and 4 screw feet for ultra-rugged
modules
1−CASECARRY
Power
Ethernet
Firewire
Sensor
Mechanik
HBM
6
B3510-1.0 en
B3510-1.0 en
7
HBM
Hottinger Baldwin Messtechnik GmbH
Im Tiefen See 45  64293 Darmstadt  Germany
Tel. +49 6151 803-0  Fax: +49 6151 803-9100
Email: info@hbm.com  www.hbm.com
B3510-1.0 en
 Hottinger Baldwin Messtechnik GmbH.
Modifications reserved. All details describe our products in
general form only. They are not to be understood as express
warranty and do not constitute any liability whatsoever.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising