TE 401-T Keyboard Unit

TE 401-T Keyboard Unit
KEYBOARD UNIT
Keyboard Unit
TE 401-T
TE 401-T
The TE 401-T keyboard unit has 40 buttons and 40 LEDs These buttons are read by the
software and can then be used for any desired function. The LEDs indicate the operating
status.
4 external switching elements can also be added.
26.03.2012
Page 1
KEYBOARD UNIT
TE 401-T
Technical Data
Performance data
Interfaces
12-pin connector for 4 x 3 switching elements
2-pin power connector
1 x CAN with 2 connections
Control panel
40 x function buttons / 4 x switch recesses
Signal generator
No
Electrical requirements
Supply voltage
minimum +18 V DC
Current consumption
maximum +30 V DC
127 mA – 175 mA
Supply voltage
Terminal
Dimensions
Material
240 mm / 220 mm / 40.1 mm (W x H x D)
housing: aluminum
front plate: aluminum
Miscellaneous
Article number
12-210-401-T
Hardware version
1.x
Environmental conditions
Storage temperature
-20 – +80 °C
Operating temperature
Humidity
0 – +60 °C
0 - 95 %, non-condensing
EMC stability
in accordance with EN 61000-6-2:2001 (industrial area)
Shock resistance
EN 60068-2-27
Protection Type
Page 2
150 m/s²
IP20 in accordance with EN 60529
26.03.2012
KEYBOARD UNIT
TE 401-T
Mechanical Dimensions
26.03.2012
Page 3
KEYBOARD UNIT
TE 401-T
Interface
General
The connection to the display unit is made over the CAN bus, which has the +24 V supply
integrated. An additional power supply connection is therefore not required.
Rear Panel Layout
X1, X2: CAN (Weidmüller B2L 3.5/8)
Pin
1
2
3
4
5
6
7
8
Function
CAN A (CAN LOW)
CAN B (High)
CAN A (CAN LOW)
CAN B (High)
GND
(+5 V)
GND
+24 V
X3 +24 V supply (Phoenix MCV1.5/2-G-3.5 2-pin spring terminal connector)
Pin
1
2
Page 4
Function
+24 V
GND
26.03.2012
KEYBOARD UNIT
TE 401-T
X4 Switching elements 1 – 4 (Phoenix MCV1.5/12-G-3.5 12-pin spring terminal
connector)
Switching element 1
Switching element 2
Switching element 2
Switching element 4
Pin
1
2
3
4
5
6
7
8
9
10
11
12
Function
+24 V
IN 1
IN 2
+24 V
IN 1
IN 2
+24 V
IN 1
IN 2
+24 V
IN 1
IN 2
DIP-SWITCH CAN-BUS Setup (8 x)
Switch 1 – 4
CAN-Station 0 – 15
Switch 5 – 6
Baud rate 0 – 3
Switch 7
no function
Switch 8
150R CAN termination
Additional Shipment
1 m CAN – cable with 2 x Weidmüller B2L 3,5/6)
2-pin connector plug (Phoenix 1939918)
12-pin connector plug (Phoenix 1942251)
26.03.2012
Page 5
KEYBOARD UNIT
TE 401-T
CAN BUS Setup
This section explains how to configure a CAN bus correctly. The following parameters must
first be set: Station number and data transfer rate.
CAN bus station number
Each CAN bus station is assigned its own station number (can be set from 0 to 15) With this
station number, data can be exchanged with other stations connected to the bus. Up to 16
stations can be installed in a CAN bus system. In a CAN bus system however, each station
number can only be assigned once.
Page 6
SW 1
SW 2
SW 3
SW 4
Station
0
0
0
0
0
1
0
0
0
1
0
1
0
0
2
1
1
0
0
3
0
0
1
0
4
1
0
1
0
5
0
1
1
0
6
1
1
1
0
7
0
0
0
1
8
1
0
0
1
9
0
1
0
1
10
1
1
0
1
11
0
0
1
1
12
1
0
1
1
13
0
1
1
1
14
1
1
1
1
15
26.03.2012
KEYBOARD UNIT
TE 401-T
CAN Bus Transfer Rate
Various data transfer rates (baud rates) can be set on the CAN bus. The longer the bus line
is, the lower the data transfer rate that must be selected.
SW 5
SW 6
Value
Baud rate
Maximum
length
0
0
0
615 kbit/s
60 m
1
0
1
500 kbit/s
80 m
0
1
2
250 kBit/s
160 m
1
1
3
125 kBit/s
320 m
These values are valid for the following cable: 120 Ω, Twisted Pair.
Note: For the CAN bus protocol: 1 kbit/s = 1 kBaud
CAN Bus Termination
In a CAN bus system, both end modules must be terminated. This is necessary to avoid
transmission errors caused by reflections in the line.
Module 1
Module 2
Module 3
Module n
I.e. C-IPC
Set CAN bus
termination
Set CAN-Bustermination
CAN bus connection
A switchable line termination is already built into the keyboard unit. If this unit is an endmodule, SW8 on the DIP-switch must be set.
26.03.2012
Page 7
KEYBOARD UNIT
TE 401-T
Ground
To ensure error-free function of the display, the blade terminal on the back must be
connected to the earth bus.
Earth bar
Page 8
26.03.2012
KEYBOARD UNIT
TE 401-T
Addressing
Data that can be sent over CAN:
1.
2.
3.
4.
5.
PS/2-Keyboard (not used)
Machine keyboard initialization
Machine buttons
LED control
Display detection and settings
Items 1 and 5:
The following CAN objects are reserved for the PS / 2 keyboard area and display detection:
040 hex to 08F hex
Through the different station numbers, 16 independent terminals can be operated in one
system. The station numbers are set using the DIP-Switch on the back. In addition, one
terminal must be defined as a master, which answers global objects (e.g. NumLock or
CapsLock).
Since there are a limited number of objects available in the CAN controller (max. 14
standard objects), the machine buttons are limited to 2 objects.
Items 2, 3 and 4:
Send object
Object number: $120-$12F (depending on station)
Object size: 2 bytes
Application for initialization, setting LEDs
Data 0
Data 1
Initialization
All LEDs off
All LEDs on
All LEDs blink
One LED off
One LED on
One LED
blinking
CMD =
$80
Bit 0 – 2:
Repetition
rate
CMD = $00
CMD = $01
CMD = $02
CMD = $10
CMD = $11
---
---
---
LED-Nr.
LED-Nr.
CMD =
$12
LED-Nr.
26.03.2012
Page 9
KEYBOARD UNIT
TE 401-T
Receive object:
Object number: $130 - $13F (depending on station)
Object size: 4 bytes
Application for button codes, answering LEDs
ACK for LEDs
Data 0
Data 1
Data 2
Data 3
CMD = $00
Button Codes
CMD = $10
Button code 1
Button code 2
Key switch
Button Layout
Page 10
26.03.2012