BLOCK BATTERY

BLOCK BATTERY
BLOCK BATTERY
TM
Made in USA
SERIES “S”
S400 - 14 or 28 VDC Switchable Block Battery
A switchable voltage battery designed for power hungry cinematic camera
rigs, the “S400” provides a 400 watt hour capacity with nominal outputs at
28.8 volts or 14.4 volts, at up to 15 amps in either voltage.
LCD Power Meter
Hours of output power used
Amount of output power remaining
Battery
0.34 WHrs
29.2 V 3.54 Amps
Check
e
Fus
5
Ba
tte
ry
Fu
se
3
Power Meter
or
ect
er
arg
1
6
Ch
nn
Co
Voltage output at battery
S400 Features
B
r
te
at
y
ec
k
h
ar
g
er
p
In
u
t
r
e
e
Am
ps
r
te
e
M
o
V
to
ec
el
S h
e itc
ag
lt Sw
5
F
1- or S
88 e
8- rvi
42 ce
4- C
63 al
22 l
r
0
0
4
S
1
3
om
.c
ER
Y
w
SH
o
PU
P
t
u
tp
u
SH
C
A
290.34
.2 W
V Hrs
3.
54
ry
PU
te
at
B
h
C
US
O
4
e in
.8
8
2
Fa
n
BL
OC
KB
AT
T
Mad
1
.4
4
u
O
PU
SH
t
u
tp
2
Amount of current being
drawn by output device
PU
SH
1
Fus
1 Output Connector Types:
Two connectors @ nominal 28.8 Volt (~20-34VDC)
Two connectors @ nominal 14.4 Volt (~10-17VDC)
Model
Volts
Connector Type
S400-33044 28.8V 3-Pin XLR, Arri Standard (Pin 1 Gnd, Pin 2 Bat +)
(Pictured)
14.4V 4-Pin XLR, (Pin 1 Gnd, Pin 4 Bat +)
S400-22044 28.8V 2-Pin Amphenol (Pin A Gnd, Pin B Bat +)
(Not-Pictured) 14.4V 4-Pin XLR,(Pin 1 Gnd, Pin 4 Bat +)
Note: Optional connectors available on request
2 Output Selector Switch:
14 VDC OR 28 VDC
3 Power Metering:
4
LCD Screen (Press battery check button to show power status)
Note: Automatically turns ON when battery is in use and turns
OFF when charging battery
4 Cooling Fans:
Fans automatically turn ON/OFF for battery temperature control
Note: Fans ONLY turn on when battery is being charged
5 Battery Fuses:
15 Amp replacement size (2 Required)
S400 Operation and Storage
6 Charge Connector:
Connects to EFC-1, EFC-2 or 2F1-Charger
Output Capacity when Fully Charged:
CAUTION:
400 watt hours, or 28 amp hours @ 14VDC, or 14 amp hours @ 28VDC
Estimated Runtime: ~ 4 hours on Alexa, or 3 hours on F65, depending
on camera rig accessories
Use BLOCK BATTERY chargers ONLY. Charge cycle
completion is indicated with GREEN LED. If removing S400
BEFORE charging cycle completion, then make sure Power
Meter voltage reads 34 Volts or Less BEFORE plugging in
output device. Otherwise device being powered could
shutdown or be DAMAGED. Voltage typically settles below
34 volts within an hour of being disconnected from charger.
Charging Time for Empty Battery:
~ 5.5 hours on EFC-1, EFC-2 or 2F1-Charger
Battery Shut-Off at End of Discharge Cycle:
Output power will automatically shut-off when:
28 VDC output power is discharged to 20 V (Approximate)
14 VDC output power is discharged to 10 V (Approximate)
S400-G-7-15
S400 Specifications
Short Term S400 Storage (Up to 1 Week):
S400 Dimensions:
5° to 25°C (41° to 77°F)
No output device plugs connected
OK to leave charger connected
9.5” (24 cm) Height x 10.5” (27 cm) Width x 6” (15 cm) Depth
S400 Weight:
Long Term S400 Storage (More than 1 Week):
S400 Battery Type:
5° to 25°C (41° to 77°F)
Fully charge battery
No output device plugs connected
Do not leave charger connected
Recharge every two months
Nickel Metal-Hydride (NiMH)
18 lbs (8.16 Kg)
S400 is Unrestricted for Air & Ground Transport
For technical support call:
Copyright 2015 NK Products Inc. All rights reserved.
1-888-424-6322
Was this manual useful for you? yes no