ABB string inverters PVI-10.0/12.5-TL

ABB string inverters PVI-10.0/12.5-TL
Solar inverters
ABB string inverters
PVI-10.0/12.5-TL-OUTD
10 to 12.5 kW
Designed for commercial usage, this
PVI-10/12.5, three-phase inverter is
highly unique in its ability to control
the performance of the PV panels,
especially during periods of variable
weather conditions.
The high speed and precise Maximum
Power Point Tracking (MPPT) algorithm
provides real-time power tracking and
improved energy harvesting.
Two independent MPPTs and
efficiency ratings up to 97.8%
This transformerless device has two
independent MPPTs and efficiency
ratings of up to 97.8%.
Flat efficiency curves ensure high
efficiency at all output levels ensuring
consistent and stable performance
across the entire input voltage and
output power range.
The wide input voltage range makes
the inverter suitable for low power
installations with reduced string size.
Highlights
− − True three-phase bridge topology for
DC/AC output converter
− − Transformerless topology
− − Each inverter is set on specific grid
codes which can be selected in the
field
− − Wide input voltage range
− − Dual input section with independent
MPPT allows optimal energy
harvesting from two sub-arrays
oriented in different directions
Additional highlights
−− Integrated DC disconnect switch
in compliance with international
standards (-S and -FS versions)
− − Natural convection cooling for
maximum reliability
− − Outdoor enclosure for unrestricted
use under any environmental
conditions
− − RS-485 communication interface (for
connection to laptop or datalogger)
Technical data and types
Type code
Input side
Absolute maximum DC input voltage (Vmax,abs)
Start-up DC input voltage (Vstart)
Operating DC input voltage range (Vdcmin...Vdcmax)
Rated DC input voltage (V dcr)
Rated DC input power (Pdcr)
Number of independent MPPT
Maximum DC input power for each MPPT (PMPPTmax)
DC input voltage range with parallel configuration of MPPT
at Pacr
DC power limitation with parallel configuration of MPPT
DC power limitation for each MPPT with independent
configuration of MPPT at P acr, max unbalance example
Maximum DC input current (Idcmax) / for each MPPT (IMPPTmax)
Maximum input short circuit current for each MPPT
Number of DC inputs pairs for each MPPT
DC connection type
Input protection
Reverse polarity protection
Input over voltage protection for each MPPT - varistor
Photovoltaic array isolation control
DC switch rating for each MPPT (version with DC switch)
Fuse rating (versions with fuses)
Output side
AC grid connection type
Rated AC power (Pacr @cosφ=1 )
Maximum AC output power (P acmax @cosφ=1)
Maximum apparent power (Smax)
Rated AC grid voltage (V ac,r)
AC voltage range
Maximum AC output current (Iac,max)
Contributory fault current
Rated output frequency (f r)
Output frequency range (fmin...fmax)
Nominal power factor and adjustable range
Total current harmonic distortion
AC connection type
Output protection
Anti-islanding protection
Maximum external AC overcurrent protection
Output overvoltage protection - varistor
Operating performance
Maximum efficiency (η max)
Weighted efficiency (EURO/CEC)
Feed in power threshold
Night consumption
2 ABB solar inverters | Product flyer for PVI-10.0/12.5-TL-OUTD
PVI-10.0-TL-OUTD
PVI-12.5-TL-OUTD
900 V
360 V (adj. 250...500 V)
0.7 x V start…850 V (min 200 V)
580 V
10300 W
12800 W
2
6500 W
8000 W
300...750 V
360...750 V
Linear derating from max to null [750 V≤VMPPT≤850 V]
8000 W [445 V≤VMPPT≤750 V]
6500 W [380 V≤V MPPT≤750 V]
the other channel: Pdcr-6500 W
the other channel: Pdcr-8000 W
[225 V≤V MPPT≤750 V]
[270 V≤V MPPT≤750 V]
34.0 A / 17.0 A
36.0 A / 18.0 A
22.0 A
2
PV quick fit connector 3)
Inverter protection only, from limited current source
Yes
According to local standard
25 A / 1000 V
15 A / 1000 V
Three-phase 3W+PE or 4W+PE
10000 W
11000 W 4)
11500 VA
12500 W
13800 W 5)
13800 VA
400 V
320...480 V
1)
16.6 A
19.0 A
20.0 A
22.0 A
50 Hz / 60 Hz
47...53 Hz / 57…63 Hz 2)
> 0.995, adj. ± 0.9 with Pacr =10.0 kW,
> 0.995, adj. ± 0.9 with Pacr =12.5 kW,
± 0.8 with max 11.5 kVA
± 0.8 with max 13.8 kVA
< 2%
Screw terminal block, cable gland M40
According to local standard
25.0 A
3 plus gas arrester
97.8%
97.1% / -
97.2% / 30.0 W
< 1.0 W
Block diagram of PVI-10.0/12.5-TL-OUTD
IN1.1(+)
IN1.2(+)
IN1.1(+)
+
+
IN1.2(+)
IN1
IN1
IN1.1(-)
-
IN1.2(-)
+
IN1.1(-)
-
MPPT 1
(DC/DC)
Bulk caps
Inverter
(DC/AC)
IN1
Line
filter
-
Grid parallel
relay
L1
IN1.2(-)
L2
L3
N
IN2.1(+)
IN2.2(+)
IN2.1(+)
+
IN2
IN2
IN2.1(-)
-
IN2.2(-)
+
+
IN2.2(+)
IN2.1(-)
MPPT 2
(DC/DC)
PE
IN2
-
-
IN2.2(-)
Standard version
-S version
IN1.1(+)
+
IN1.2(+)
IN1
IN1.1(-)
-
RS485
IN1.2(-)
+ T/R
- T/R
RTN
DC/AC
DSP
contr.
DC/DC
DSP
contr.
IN2.1(+)
Remote control
+R
+
IN2.2(+)
-R
µP
IN2
Alarm
N.C
IN2.1(-)
N.O
-
C
IN2.2(-)
Control circuit
-FS version
Technical data and types
Type code
Communication
Wired local monitoring
Remote monitoring
Wireless local monitoring
User interface
Environmental
Ambient temperature range
Relative humidity
Sound pressure level, typical
Maximum operating altitude without derating
Physical
Environmental protection rating
Cooling
Dimension (H x W x D)
Weight
Mounting system
Safety
Isolation level
Marking
Safety and EMC standard
Grid standard (check your sales channel for availability)
Available products variants
Standard
With DC switch
With DC switch and fuse
PVI-10.0-TL-OUTD
PVI-12.5-TL-OUTD
PVI-USB-RS232_485 (opt.)
VSN300 Wifi Logger Card (opt.), VSN700 Data Logger (opt.)
VSN300 Wifi Logger Card (opt.)
16 characters x 2 lines LCD display
-25...+60°C (-13...+140°F)
-25...+60°C (-13...140°F)
with derating above 55°C (131°F)
with derating above 50°C (122°F)
0...100% condensing
50 dBA @ 1 m
2000 m / 6560 ft
IP65
Natural
716 mm x 645 mm x 224 mm / 28.2” x 25.4” x 8.8”
< 41.0 kg / 90.4 lbs
Wall bracket
Transformerless
CE (50 Hz only), RCM
EN 50178, IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 3100, AS/NZS 60950.1,
EN 61000-6-2, EN 61000-6-3, EN 61000-3-11, EN 61000-3-12
CEI 0-21, CEI 0-16, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G59/3, C10/11,
EN 50438 (not for all national appendices), RD 1699, RD 413, RD 661, P.O. 12.3,
AS/NZS 4777, IEC 61727, IEC 62116, BDEW, MEA, NRS 097-2-1, VFR 2014
PVI-10.0-TL-OUTD
PVI-10.0-TL-OUTD-S
PVI-10.0-TL-OUTD-FS
PVI-12.5-TL-OUTD
PVI-12.5-TL-OUTD-S
PVI-12.5-TL-OUTD-FS
4)
The AC voltage range may vary depending on specific country grid standard
Limited to 10000 W for Belgium and Germany
5)
The Frequency range may vary depending on specific country grid standard
Limited to 12500 W for Germany
3)
Please refer to the document “String inverters – Product manual appendix” available at www.abb.com/solarinverters for information on the quick-fit connector brand and
model used in the inverter
Remark. Features not specifically listed in the present data sheet are not included in the product
1)
2)
Product flyer for PVI-10.0/12.5-TL-OUTD | ABB solar inverters 3
Efficiency curves of PVI-12.5-TL-OUTD
99
99
98
98
97
97
96
96
Efficiency [%]
95
94
95
94
93
93
300 Vdc
92
360 Vdc
92
580 Vdc
580 Vdc
91
90
91
750 Vdc
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
90
750 Vdc
0%
10%
Support and service
ABB supports its customers with
dedicated, global service organization
in more than 60 countries and strong
regional and national technical partner
networks providing complete range of
life cycle services.
20%
30%
40%
50%
60%
70%
80%
90%
100%
% of rated Output Power
% of rated Output Power
For more information please contact
your local ABB representative or visit:
www.abb.com/solarinverters
www.abb.com/solar
www.abb.com
© Copyright 2016 ABB. All rights reserved.
Specifications subject to change without notice.
BCD.00378 EN Rev. E 06.06.2016
Efficiency [%]
Efficiency curves of PVI-10.0-TL-OUTD