Power Systems: Overview of SDMC

Power Systems: Overview of SDMC
Power Systems
Overview of SDMC
Power Systems
Overview of SDMC
Note
Before using this information and the product it supports, read the information in “Notices” on page 33.
This edition applies to IBM Systems Director Management Console Version 6 Release 730 and to all subsequent
releases and modifications until otherwise indicated in new editions.
© Copyright IBM Corporation 2011.
US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract
with IBM Corp.
Contents
SDMC concepts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Comparing HMC and SDMC features . . . . . . . . . . . . . . . . . . . . . . . 3
Comparing the HMC and SDMC . . . . . . . . . . . .
How the SDMC is used. . . . . . . . . . . . . . . .
Virtualization enhancements . . . . . . . . . . . . . .
Terminology differences between HMC and SDMC . . . . . .
Navigation differences between the HMC GUI and the SDMC GUI .
Comparing HMC tasks and SDMC tasks . . . . . . . . . .
Server (host) tasks . . . . . . . . . . . . . . . .
Partition (virtual server) tasks . . . . . . . . . . . .
Frame (power unit) tasks . . . . . . . . . . . . . .
HMC and SDMC management tasks . . . . . . . . . .
Service management . . . . . . . . . . . . . . .
Functional differences between the HMC, IVM, and SDMC . .
SDMC supported and unsupported systems . . . . . . . .
Supported configurations . . . . . . . . . . . . . . .
SDMC redundancy and high availability features . . . . . . .
SDMC and HMC command-line differences . . . . . . . .
Systems Director Management Console limitations . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 3
. 3
. 4
. 4
. 7
. 9
. 9
. 14
. 17
. 18
. 22
. 24
. 25
. 26
. 27
. 30
. 32
Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Trademarks . . . .
Terms and conditions .
© Copyright IBM Corp. 2011
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 34
. 35
iii
iv
Power Systems: Overview of SDMC
SDMC concepts
The IBM Systems Director Management Console (SDMC) is the next generation Hardware Management
Console (HMC) that combines the functions of the HMC, the simplicity of the Integrated Virtualization
Manager (IVM), and the value-add functions of the IBM® Systems Director. The SDMC provides server
management and PowerVM™ virtualization management.
The SDMC is a management console for managing IBM Power Systems™ servers and IBM BladeCenter®
Power blade servers. The SDMC is an alternative and replacement for the current HMC with enhanced
virtualization and hardware management capabilities. The SDMC is an x86-based console. The SDMC
manages IBM AIX®, IBM i, or Linux operating systems on IBM Power Systems servers and IBM
BladeCenter Power blade servers.
© Copyright IBM Corp. 2011
1
2
Power Systems: Overview of SDMC
Comparing HMC and SDMC features
You need to understand the differences between the Hardware Management Console (HMC), Integrated
Virtualization Manager (IVM), and IBM Systems Director Management Console (SDMC) environments
including terminology, users and roles, supported features, high availability options, and command-line
differences.
Comparing the HMC and SDMC
There are some important differences between the HMC and the SDMC.
With the SDMC, the scope of administered systems spans from POWER blade servers to high-end
systems, providing a single, consistent approach to systems administration.
The characteristics of both the HMC and the SDMC, at a high level, follow:
HMC
v Is implemented as an external, independent appliance
v Can administer entry-level systems to high-end systems
v Can administer more than one managed system
v Allows for more than one VIOS per managed system
SDMC
v SDMC is offered as an appliance in two forms:
– A hardware appliance similar to the HMC, using essentially the same hardware plus additional
memory and disk.
– A virtual appliance that runs in a VMware partition
v Can administer entry-level systems to high-end systems
v Can administer more than one managed system
v Allows for more than one VIOS per managed system
v Supports entry-level systems to high-end systems plus blades.
How the SDMC is used
SDMC represents the next generation of management appliances for POWER processor-based systems.
The SDMC replaces both the HMC and IVM in POWER processor-based systems administration. Thus,
the SDMC can manage POWER systems directly but can also work with the HMC and IVM side by side
to ease transition.
SDMC is integrated into the administrative framework of IBM Systems Director. It provides a common
interface for systems administration across the data center. If you have used an HMC or IVM, you will
already be familiar with SDMC tasks and procedures. The Systems Director provides additional tasks that
you might want to explore. Note that these additional Systems Director tasks and navigation options
might make it more difficult to find familiar HMC tasks. For more information about navigating the
SDMC GUI, see “Navigation differences between the HMC GUI and the SDMC GUI” on page 7.
The SDMC can unify platform management for IBM Systems, providing a consistent interface for
common management tasks. By integrating POWER processor-based systems management into the IBM
Systems Director framework, you can easily manage many systems of different types. The SDMC also
enables the integration of POWER processor-based systems into data center management tools.
© Copyright IBM Corp. 2011
3
As a successor to both the HMC and IVM, the SDMC administrators can work with a high-level view of
systems. It organizes tasks in a single window, instead of using different menus. This interface simplifies
views on systems and provides faster access to day-to-day tasks.
As it was with older POWER processor-based systems, the transition to the SDMC requires that
management for POWER5 and POWER5+ processor based systems continue with either the HMC or
IVM. The SDMC can administer the HMC and IVM as well; however, this management console eases
transition from older environments into new ones.
Virtualization enhancements
SDMC has made managing your virtualization environment significantly easier, while maintaining all of
the HMC's existing functions.
The enhancements follow:
Virtual I/O management
In addition to the HMC's Virtual Storage Management view, The SDMC brings similar
simplification to the Create Virtual Server and Manage Virtual Server views. With SDMC, you can
see the storage devices attached to a virtual server and need not be concerned about your virtual
SCSI device pairs and the VIOS command-line.
Simplified Create Virtual Server wizard
Create Virtual Server (known as logical partition on the HMC) wizard asks only what is needed
to create the virtual server, and selects reasonable defaults for all other settings. Advanced users
who want full control can change the profile after the wizard is completed to control all of their
settings, such as min/max values. You can now create a virtual server by simply specifying the
name and clicking Finish.
Managing virtual server
A task called Manage Virtual Server displays virtual server properties and I/O device
configuration information in one window. With this task, you control the resource assignments
for a virtual server directly (whether the virtual server is powered on or off) without using a
profile.
Terminology differences between HMC and SDMC
The HMC and SDMC environments use different terminology.
For integration into IBM Systems Director, SDMC introduces some synonyms that replace familiar HMC
terms. The key ones to remember are the following:
v Virtual Server (formerly Partition)
v Host (formerly Managed System or Server)
v Power Unit (formerly Frame)
For detailed information about the terminology differences between the HMC and the SDMC, see the
following tables.
Table 1. Networking terms
HMC
SDMC
Description
Open network
Standard network
The standard network can be
connected to a firewall or router for
connecting to the Internet.
4
Power Systems: Overview of SDMC
Table 2. Objects
HMC
SDMC
Description
Hardware Management Console
(HMC), Integrated Virtualization
Manager (IVM)
Platform manager
A platform manager manages one or
more hosts and their associated
virtual servers and operating
systems. For Power Systems servers,
the platform managers are HMC and
IVM.
Frame, bulk power assembly (BPA)
Power unit
The power assembly for processor,
memory, FSP, and I/O enclosures.
Server, managed system, system,
flexible service processor (FSP),
central electronics complex (CEC)
Host
A physical server that contains
physical processors, memory, and
I/O resources. The physical server is
often virtualized into virtual servers,
also known as logical partitions.
Logical partition (LPAR), dynamic
LPAR (DLPAR), partition
Virtual server
The collection of processor, memory
and I/O resources defined to run an
operating system and its applications.
Virtual I/O Server (VIOS)
Utility virtual server
A virtual server that provides
virtualization capabilities for a
particular environment.
HMC
SDMC
Description
Remove connection – systems
Remove host
The remove tasks removes the host
from the directory database.
HMC
SDMC
Description
hscroot
sysadmin
Predefined administrator user for the
platform manager.
hscpe
pe
Predefined service and support user
for the platform manager.
hmcsuperadmin
SMAdministrator (Administrator
role)
The Administrator role has full
authority to all resources and tasks,
including security administration,
product installation, and
configuration.
hmcoperator
SMManager (Manager role)
The Manager role can perform a
subset of the tasks that an
administrator can perform. Typically,
system administration, system health
management, and configuration tasks
are available.
N/A
SMUser (User role)
The User role includes any
authenticated user and allows only
basic operations such as viewing
resources and properties.
Table 3. Tasks
Table 4. Users and roles
Comparing HMC and SDMC features
5
Table 4. Users and roles (continued)
HMC
SDMC
Description
hmcviewer
SmMonitor (Monitor role)
The Monitor role can access those
administrative functions that provide
read-only access. Primarily,
monitoring, notifications, and status
tasks are available.
hmcservicerep
SMServiceRep (PE role)
The PE role includes the pe user and
gives users the ability to perform
only service operations, such as
viewing resources, logs, and system
status and health.
Table 5. Hosts and system states.
Note: SDMC states include operating states, detailed states, and health states.
HMC states
SDMC operating states
SDMC detailed states
SDMC health states
Operating
Started
N/A
OK
Standby
Standby
N/A
OK
Power off
Stopped
N/A
OK
Service processor failover
Started
Service processor failover
Degraded/warning
Power off in progress
Stopping
N/A
OK
Initializing
Starting
N/A
OK
No connection * (should be
handled by Access Point
state)
Not available
Unknown
Unknown
Pending authentication
Waiting for input
Password updates required
Degraded/warning
Failed Authentication *
(Should be handled by
Access Point state, that is,
Failed Access)
Not available
Unknown
Unknown
Error
Error
Unknown
Critical failure
Error - terminated
Error
Terminated
Critical failure
Error - dump in progress
Error
Dump in progress
Critical failure
Recovery
Error
Recovery
Critical failure
Incomplete
Error
Incomplete
Critical failure
Version mismatch
Error
Version mismatch
Major failure
Table 6. Virtual server and partition states
HMC states
SDMC operating states
SDMC detailed states
SDMC health states
Running
Started
N/A
OK
Starting
Starting
N/A
Not activated
Stopped
N/A
Unknown
Migrating - not activated
Relocating
N/A
OK
Migrating - running
Relocating
N/A
OK
Shutting down
Stopping
N/A
OK
Open firmware
Waiting for input
Open firmware
OK
6
Power Systems: Overview of SDMC
Table 6. Virtual server and partition states (continued)
HMC states
SDMC operating states
SDMC detailed states
SDMC health states
Hardware discovery
Started
Performing hardware
discovery
OK
Error
Error
Unknown
Major failure
Not available
Not available
Unknown
Unknown
HMC state
SDMC Operating State
SDMC Detailed State
SDMC Health State
Standby
Standby
N/A
Degraded
Standby/starting
Standby
N/A
OK
Starting
Starting
N/A
Pending frame number
change
Standby
N/A
Degraded
Failed authentication
Not Available
Unknown
Unknown
Pending authentication
Waiting for input
Password updates required
Degraded / Warning
No connection
Not available
Unknown
Unknown
Incomplete
Error
Incomplete
Critical failure
Version mismatch
Error
Version mismatch
Major failure
Table 7. Power unit states
Navigation differences between the HMC GUI and the SDMC GUI
This section describes the differences in navigating to commonly used Hardware Management Console
(HMC) tasks on the HMC and on the Systems Director Management Console (SDMC).
Because IBM Systems Director manages many different types of objects, it has a generic navigation style.
Systems Director groups managed objects and shows general properties for each object. The SDMC
interface is quite similar to the HMC interface.
Below is a list of commonly-used HMC tasks, and where they can now be found in the SDMC interface:
Viewing host (server) properties by using the SDMC interface
The Properties task in SDMC is different from that of the HMC. The SDMC now calls a server a host.
To view server properties by using the HMC, complete the following steps:
1. In the navigation pane, selectSystems Management.
2. Select the server.
3. In the contents pane, select Tasks > Properties.
To view host properties by using the SDMC, complete the following steps
1. From the Resources page, right-click the host.
2. Select System Configuration > Edit Host.
Viewing virtual server (partition) properties by using the SDMC interface
To view partition properties by using the HMC, complete the following steps:
1. In the navigation pane, selectSystems Management.
Comparing HMC and SDMC features
7
2. In the contents pane, expand the server.
3. Select the logical partition.
4. Click Tasks > Properties.
The SDMC now calls a partition a virtual server.
To view virtual server properties using the SDMC, complete the following steps:
1. From the Resources page, select the virtual server.
2. Click System Configuration > Manage Virtual Server.
Discovering a system to manage using the SDMC interface
Discovery is a general Systems Director concept of finding a system or object to manage. You can use the
SDMC interface to discover and manage the following objects:
v Host flexible service processors (FSPs) and host power units
v Bulk power controllers (BPCs) and frames
v Operating systems
If you are using the SDMC as a Dynamic Host Configuration Protocol (DHCP) server for your managed
systems, the FSPs and BPCs are discovered automatically. If you are not using the SDMC as a DHCP
server, you can discover the resource by entering a host name, an IP address, or a range of IP addresses
in the Discover section of the GUI or the command-line interface (CLI).
To discover a system to manage by using the HMC, complete the following steps:
1. In the navigation pane, selectSystems Management.
2. Select the server.
To
1.
2.
3.
discover a host to manage by using the SDMC, complete the following steps:
On the Resources page, clickCommon Tasks > System Discovery.
Select a discovery option, IP address, and the resource type to discover.
Click Discover now.
Powering a server (host) on or off by using the SDMC interface
To power a server on or off by using the HMC, complete the following steps:
1. In the navigation pane, selectSystems Management.
2. Select the server.
3. In the contents pane, select Tasks > Operations > Power On or Tasks > Operations > Power Off.
The SDMC now calls a server a host.
To power a host on or off by using the SDMC, complete the following steps:
1. From the Resources page, right-click the host.
2. Select Operations > Power on or Operations > Power off.
Creating a logical partition (virtual server) by using the SDMC interface
To
1.
2.
3.
8
create a logical partition by using the HMC, complete the following steps:
In the navigation pane, selectSystems Management.
Select the server on which you want to create a logical partition.
In the contents pane, select Tasks > Configuration > Create logical partition.
Power Systems: Overview of SDMC
The SDMC calls a partition a virtual server. To create a virtual server by using the SDMC, compete the
following steps:
1. From the Resources page, right-click the host.
2. Select Create Virtual Server.
Comparing HMC tasks and SDMC tasks
This section provides detailed task information for moving from Hardware Management Console (HMC)
to Systems Director Management Console (SDMC) for each HMC task.
Server (host) tasks
This topic provides server task information for moving from HMC to SDMC. Servers are known as hosts
on the SDMC.
The following task mapping information is available in this topic:
v Server (host) properties task mapping
v Server (host) operations task mapping
v Server (host configuration task mapping
v Server (host) connections task mapping
v
v
v
v
Server
Server
Server
Server
(host)
(host)
(host)
(host)
hardware information task mapping
updates task mapping
serviceability task mapping
Capacity on Demand task mapping
Table 8. Server (host) properties task mapping
HMC task
SDMC task
Is the task identical?
Notes
View Properties
System Configuration >
Edit Host
Yes
The properties task on
SDMC is different from that
on the HMC.
For more information about
performing this task, see
Changing host properties.
Table 9. Server (host) operations task mapping
HMC task
SDMC task
Is the task identical?
Notes
Power On and Power Off
Operations > Power On /
Power Off
No
The function is the same,
but the interface is
different.
For more information about
performing this task, see
Powering on the host.
Power Management
Operations > Power
Management
No
The function is the same,
but the interface is
different.
For more information about
performing this task, see
Performing POWER
management operations.
Comparing HMC and SDMC features
9
Table 9. Server (host) operations task mapping (continued)
HMC task
SDMC task
Is the task identical?
Notes
LED Status > Deactivate
Attention LED
Service and Support >
Hardware > System
Attention LED
Yes
For more information about
performing this task, see
Activating and deactivating
the Attention LED.
LED Status > Identify LED
Service and Support >
Hardware > Identify LED
Yes
For more information about
performing this task, see
Locating parts with the
Identify LED.
LED Status > Test LED
Service and Support >
Hardware > LED Lamp
Test
Yes
For more information about
performing this task, see
Performing an LED lamp
test.
Schedule Operations
Operations > Schedule
Operations
No
The function is the same,
but the interface is
different.
For more information about
performing this task, see
Scheduling host operations.
Launch Advanced System
Management (ASM)
Operations > Launch
Advanced System
Management (ASM)
No
The function is the same,
but the interface is
different.
For more information about
performing this task, see
Launching Advanced
System Management.
Utilization Data > Change
Sampling Rate
Operations > Utilization
Data > Change Sampling
Rate
Yes
For more information about
performing this task, see
Changing the sampling rate
for utilization data.
Utilization Data > View
Operations > Utilization
Data > View Utilization
Data
Yes
For more information about
performing this task, see
Viewing host utilization
data.
Rebuild
Operations > Rebuild
Managed System
No
The function is the same,
but the interface is
different.
For more information about
performing this task, see
Rebuilding a managed
system.
Change Password
Operations > Change
Password
No
The function is the same,
but the interface is
different.
For more information about
performing this task, see
Changing host passwords
10
Power Systems: Overview of SDMC
Table 10. Server (host) configuration task mapping
HMC task
SDMC task
Is the task identical?
Notes
Create Logical Partition
System Configuration >
Create Virtual Server
No
The HMC has 3 separate
tasks. The SDMC combines
these tasks into one task.
For more information about
performing this task, see
Creating virtual servers.
System Plans >
Create/Deploy
System Configuration >
Manage System Plans
Mostly
The SDMC task places all
system plan function under
the Manage System Plans
task.
For more information about
performing this task, see
Creating a system plan by
using the SDMC.
View Workload
Management Groups
System Configuration >
View Workload
Management Groups
Yes
Manage Profile Data >
Restore/Initialize/Backup/
Delete
Yes
System Configuration >
Manage Virtual Server Data
> Restore/Initialize/
Backup/Delete
For more information about
performing this task, see
Managing profiles for
virtual servers.
Manage System Profiles
System Configuration >
Manage System Profiles
For more information about
performing this task, see
Managing system profiles.
Virtual Resources > Virtual
Storage Management
System Configuration >
Virtual Resources > Virtual
Storage Management
Virtual Resources > Virtual
Network Management
System Configuration >
Virtual Resources > Virtual
Network Management
Yes
Yes
Table 11. Server (host) connections task mapping
HMC task
SDMC task
Is the task identical?
Service Processor Status
System Configuration >
Edit Host
Yes
Reset or Remove
Connection
Security > Revoke Access,
Security > Request Access,
Remove
Notes
Revoke access removes the
connection. Request access
reestablishes it. The remove
operation is the equivalent
to Remove Connection.
For more information about
performing this task, see
Revoking connection access.
Disconnect Another
Management Console
Service and Support >
Reset Other Management
Console Connection
Comparing HMC and SDMC features
11
Table 11. Server (host) connections task mapping (continued)
HMC task
SDMC task
v Add Managed System
v Common Tasks > System
Discovery
v Update Password
Is the task identical?
Notes
Adding a system is a
two-step process on SDMC.
First, discover the system,
and then request access. On
the HMC it can be done in
one step.
v Security > Request
Access
For more information about
performing this task, see
Adding hosts to the SDMC.
Table 12. Server (host) hardware information task mapping
HMC task
SDMC task
Is the task identical?
Adapters > Host Ethernet
Hardware Information >
Adapter > Host Ethernet
Yes
Adapters > Host Channel
Hardware Information >
Adapter > Host Channel
Yes
View Hardware Topology
Hardware Information >
View Hardware Topology
Yes
Notes
Table 13. Server (host) updates task mapping
HMC task
SDMC task
Is the task identical?
Notes
Change Licensed Internal
Code
Release Management > See
notes
No
The HMC uses a wizard for
updates, whereas the
SDMC has separate steps
for updates. Update tasks
are under the Release
Management menu.
For more information about
performing this task, see
Updating the host.
Upgrade Licensed Internal
Code
Release Management > See
notes
No
Upgrade, change, and
update operations have the
same user flow on SDMC.
For more information about
performing this task, see
Updating the host.
Check System Readiness
Release Management >
Readiness Check
No
View System Information
Release Management >
Power Firmware
Management
No
In SDMC, power-specific
update tasks are under the
Power Firmware
Management task.
For more information about
performing this task, see
Managing Power system
firmware.
12
Power Systems: Overview of SDMC
Table 14. Server (host) serviceability task mapping
HMC task
SDMC task
Is the task identical?
Notes
Manage Serviceable Events
Properties > Active Status > No
Category: Service Status
Create Serviceable Event
Service and Support >
Submit Service Request
No
For more information about
performing this task, see
Submitting service request
using Service and Support
Manager.
Reference Code History
Service and Support >
Reference Code History
Yes
For more information about
performing this task, see
Reference Code History.
Control Panel Functions >
(20) Type, Model, Feature
Service and Support >
Control Panel Functions >
(20) Type, Model, Feature
Yes
For more information about
performing this task, see
Control Panel Functions.
Hardware > Prepare For
Hot Repair/Upgrade
Service and Support >
Hardware > Prepare For
Hot Repair/Upgrade
Yes
For more information about
performing this task, see
Preparing for Hot Repair or
Upgrade.
Hardware > Exchange FRU Service and Support >
Yes
Hardware > Exchange FRU
For more information about
performing this task, see
Exchange FRU.
Yes
Hardware > Power On/Off Service and Support >
Unit
Hardware > Power On/Off
Unit
For more information about
performing this task, see
Power On/Off Unit.
Hardware > MES Tasks
Service and Support >
Hardware > MES Tasks
Yes
For more information about
performing this task, see
MES tasks.
Manage Dumps
Service and Support >
Support Files
No
For more information about
performing this task, see
Managing support files by
using Service and Support
Manager.
Manage Dumps > System
Dump Parameters
Service and Support >
Dump Settings
No
For more information about
performing this task, see
Managing support files by
using Service and Support
Manager.
Collect VPD
Inventory > View and
Collect Inventory
No
FSP Failover >
Setup/Initiate
Service and Support > FSP
Failover > Failover
Initiate/Failover Setup
Yes
For more information about
performing this task, see
Managing serviceable
problems by using Service
and Support Manager.
For more information about
performing this task, see
FSP Failover.
Comparing HMC and SDMC features
13
Table 15. Server (host) Capacity on Demand task mapping
HMC task
SDMC task
Is the task identical?
All Tasks
System Configuration >
No
Capacity on Demand (CoD)
Notes
SDMC has combined all
CoD functions into one
Manage task.
For more information about
performing this task, see
Capacity on Demand for
SDMC.
Partition (virtual server) tasks
This topic provides partition task information for moving from HMC to SDMC. Partitions are known as
virtual servers on the SDMC..
The following task mapping information is available in this topic:
v Partition (virtual server) task mapping
v Partition (virtual server) operations task mapping
v Partition (virtual server) configuration task mapping
v Partition (virtual server) hardware configuration task mapping
v Partition (virtual server) Dynamic Logical Partitioning (DLPAR) task mapping
v Partition (virtual server) console window task mapping
v Partition (virtual server) serviceability task mapping
Table 16. Partition (virtual server) task mapping
HMC task
SDMC task
Is the task identical?
Notes
Properties
System Configuration >
Manage Virtual Server
No
SDMC has combined
Properties and dynamic
logical partitioning
(DLPAR) tasks into the
Manage Virtual Server task.
For more information about
performing this task, see
Manage virtual server
operations.
Change Default Profile
N/A
SDMC has removed this
task.
Table 17. Partition (virtual server) operations task mapping
HMC task
SDMC task
Is the task identical?
Notes
Activate > Profile
Operations > Activate >
Profile
Yes
For more information about
performing this task, see
Activating a virtual server
based on its current
configuration.
Activate > Current
Configuration
Operations > Activate >
Current Configuration
Yes
For more information about
performing this task, see
Activating a virtual server.
14
Power Systems: Overview of SDMC
Table 17. Partition (virtual server) operations task mapping (continued)
HMC task
SDMC task
Is the task identical?
Notes
Restart
Operations > Restart
Yes
For more information about
performing this task, see
Shutting down and
restarting virtual servers.
Shutdown
Operations > Shutdown
Yes
For more information about
performing this task, see
Shutting down and
restarting virtual servers.
Deactivate Attention LED
Service and Support >
Hardware > System
Attention LED
Yes
Schedule Operations
Operations > Schedule
Operations
No
This task in SDMC is done
on the server (host), not the
partition (virtual server)
Delete
Operations > Delete
Yes
For more information about
performing this task, see
Deleting a virtual server
profile.
Mobility > Migrate
Operations > Mobility >
Migrate
Yes
For more information about
performing this task, see
Moving the virtual server
with SDMC.
Mobility > Validate
Operations > Mobility >
Validate
Yes
For more information about
performing this task, see
Validating the configuration
for virtual server mobility.
Mobility > Recover
Operations > Mobility >
Recover
Yes
Suspend Operations >
Recover
Operations > Suspend
Operations > Recover
Yes
For more information about
performing this task, see
Recovering a suspended
virtual server.
Suspend Operations >
Suspend
Operations > Suspend
Operations > Suspend
Yes
For more information about
performing this task, see
Suspending a virtual server.
Table 18. Partition (virtual server) configuration task mapping
HMC task
SDMC task
Is the task identical?
Notes
Manage Profiles
System Configuration >
Manage Profiles
Yes
The Create Profile wizard
has been removed and is
replaced with the Copy
Profile which launches into
the edit profile function for
changing the profile.
For more information about
performing this task, see
Managing profiles for
virtual servers.
Manage Custom Groups
Add To > Existing Group / No
Create Group System
For more information about
performing this task, see
Managing users.
Comparing HMC and SDMC features
15
Table 18. Partition (virtual server) configuration task mapping (continued)
HMC task
SDMC task
Save Current Configuration Configuration > Save
Current Configuration
Is the task identical?
Notes
Yes
For more information about
performing this task, see
Saving the current
configuration of a virtual
server.
Table 19. Partition (virtual server) hardware configuration task mapping
HMC task
SDMC task
Is the task identical?
Notes
All Tasks
System Configuration >
Manage Virtual Server
No
For SDMC, I/O adapter
management is done under
the Manage Virtual Server
task.
For more information about
performing this task, see
Manage virtual server
operations.
Table 20. Partition (virtual server) dynamic logical partitioning (DLPAR) task mapping
HMC task
SDMC task
Is the task identical?
Notes
All Tasks
System Configuration >
Manage Virtual Server
No
For SDMC, DLPAR tasks
are done under the Manage
Virtual Server task. Note
that DLPAR Move tasks
from the GUI are a
two-step process (remove
and add).
For more information about
performing this task, see
Managing virtual servers.
Table 21. Partition (virtual server) console window task mapping
HMC task
SDMC task
Is the task identical?
Notes
Open Terminal Window
Operations > Console
Window > Open Terminal
Console
No
The TTY terminal applet
requires you to authenticate
to SDMC.
Close Terminal Connection
Operations > Console
Window > Close Terminal
Console
No
Open Dedicated 5250
Console (Local Only)
Operations > Console
Yes
Window > Open Dedicated
5250 Console (Local Only)
Launches x-Windows IBM
5250 emulator to the virtual
server in dedicated mode.
Open Shared 5250 Console
(Local Only)
Operations > Console
Window > Open Shared
5250 Console (Local Only)
Launches x-Windows IBM
5250 emulator to the virtual
server in shared mode.
16
Power Systems: Overview of SDMC
Yes
Table 22. Partition (virtual server) serviceability task mapping
HMC task
SDMC task
Is the task identical?
Notes
Manage Serviceable Events
Properties > Active Status > No
Category: Service Status
For more information about
performing this task, see
Managing serviceable
problems by using Service
and Support Manager.
Reference Code History
Service and Support >
Reference Code History
Yes
For more information about
performing this task, see
Reference Code History.
Control Panel Functions
Service and Support >
Control Panel Functions
No
For SDMC, all functions are
available in one task.
For more information about
performing this task, see
Control Panel Functions.
Frame (power unit) tasks
This topic provides frame task information for moving from HMC to SDMC. Frames are known as power
units on the SDMC.
The following task mapping information is available in this topic:
v Frame properties task mapping
v Frame connections task mapping
v Frame serviceability task mapping
v Frame operations task mapping
Table 23. Frame properties task mapping
HMC Task
SDMC Task
Is the task identical?
Notes
Frame Properties
Edit Power Unit
No
For more information about
performing this task, see
Changing power unit
properties.
Table 24. Frame connections task mapping
HMC Task
SDMC Task
Is the task identical?
Notes
Bulk Power Assembly
(BPA)
Connections > Bulk Power
Assembly (BPA) Status
No
For more information about
performing this task, see
Viewing the bulk power
assembly status.
Status Reset
Security > Revoke Access,
Security > Request Access,
Revoke
No
Revoke access removes the
connection. Request access
re-establishes it.
For more information about
performing this task, see
Requesting connection
access and Revoking
connection access.
Comparing HMC and SDMC features
17
Table 25. Frame serviceability task mapping
HMC Task
SDMC Task
Is the task identical?
Manage Serviceable Events
Properties > Active Status > No
Category:
Notes
For more information about
performing this task, see
Managing serviceable
problems by using Service
and Support Manager.
Hardware > Exchange FRU Service Status Service and
Support > Hardware >
Exchange FRU
Yes
For more information about
performing this task, see
Replace FRU.
Hardware > MES Tasks
Yes
For more information about
performing this task, see
Performing MES tasks.
Service and Support >
Hardware > MES Tasks
Table 26. Frame operations task mapping
HMC Task
SDMC Task
Is the task identical?
Notes
Initialize
Operations > Initialize
Power Unit
No
For more information about
performing this task, see
Initializing the power unit.
Launch Advanced System
Management (ASM)
Operations > Launch
Advanced System
Management (ASM)
No
For more information about
performing this task, see
Launching Advanced
System Manager.
Change Password
Operations > Change
Password
No
For more information about
performing this task, see
Changing power unit
passwords.
Rebuild
Operations > Rebuild
No
For more information about
performing this task, see
Rebuilding the power unit.
View VLAN Network Data
Service and Support > View Yes
VLAN Network Data
For more information about
performing this task, see
Viewing VLAN network
data.
HMC and SDMC management tasks
This topic provides console or appliance task information for moving from HMC to SDMC.
The following task mapping information is available in this topic:
v Update the HMC (SDMC) task mapping
v HMC (SDMC) management: operations task mapping
v HMC (SDMC) management: administration task mapping
18
Power Systems: Overview of SDMC
Table 27. Update the HMC (SDMC) task mapping
HMC task
SDMC task
Is the task identical?
Notes
Update HMC
Welcome > Settings >
Update SDMC
No
If you do not have a
connection to the Internet,
click Stop, and manually
import the updates from a
local file system or from a
File Transfer Protocol (FTP)
server.
For more information about
performing this task, see
Updating the SDMC.
Table 28. HMC (SDMC) management: Operations task mapping
HMC task
SDMC task
Is the task identical?
View HMC Events
System Status and Health > No
Event Log Welcome
Shut Down or Restart
System Status and Health > No
Event Log Welcome >
Settings > Restart SDMC
Notes
The Restart task has an
option to simply shut down
as well.
For more information about
performing this task, see
Restarting the IBM Systems
Director Management
Console.
View Trace Logs (HSCPE
Only)
Welcome > Settings >
Serviceability Tasks > View
Trace Logs (PE Only)
Yes
Schedule Operations
Task Management > Active
and Scheduled Jobs
No
Format Media
N/A
No
There is no equivalent
function in the SDMC
Back Up HMC Data
CLI: backup(hardware
appliance only)
No
The SDMC only has a CLI
for backup. This task is
available only on the
hardware appliance. The
virtual appliance can be
backed up with hypervisor
disk snapshots.
For more information about
performing this task, see
Backing up and restoring
the SDMC and Using the
SDMC remote command
line.
Comparing HMC and SDMC features
19
Table 28. HMC (SDMC) management: Operations task mapping (continued)
HMC task
SDMC task
Is the task identical?
Notes
Restore HMC Data
CLI: restore(Hardware
Appliance Only)
No
SDMC only has a CLI for
restore. This task available
only on the hardware
appliance. The virtual
appliance can be restored
from hypervisor disk
snapshots.
For more information about
performing this task, see
Backing up and restoring
the SDMC and Using the
SDMC remote command
line.
Save Upgrade Data
N/A
No
SDMC upgrades do not
need a separate save
upgrade step.
Change Network Settings
Welcome > Settings >
Configuration Tasks >
Configure Network
No
For more information about
performing this task, see
Configuring the network.
Test Network Connectivity
N/A
No
There is no equivalent UI
function in SDMC. For ping
and routing information,
the user can the
appropriate command.
For more information about
performing this task, see
Using the SDMC remote
command line.
View Network Topology
N/A
No
There is no equivalent
function in SDMC.
Tip of the Day
N/A
No
There is no equivalent
function in SDMC.
Change Default User
Interface Setting
N/A
No
There is no equivalent
function in SDMC.
Change Date and Time
Welcome > Settings >
Configuration Tasks >
Configure Date/Time
No
For more information about
performing this task, see
Configuring date and time.
Launch Guided Setup
Wizard
N/A
No
The setup wizard is only
shown on initial
configuration.
Table 29. HMC (SDMC) management: Administration task mapping
HMC task
SDMC task
Is the task identical?
Notes
Change User Password
Welcome > Settings >
Change user account
password
No
For more information about
performing this task, see
Changing user accounts
and passwords.
20
Power Systems: Overview of SDMC
Table 29. HMC (SDMC) management: Administration task mapping (continued)
HMC task
SDMC task
Is the task identical?
Notes
Manage User Profiles and
Access
Welcome > Settings >
Create user accounts
No
For more information about
performing this task, see
Managing users and
passwords.
Welcome > Settings > View
user accounts
Security > Users
Manage Tasks and
Resource Roles
Security > Roles
No
For more information about
performing this task, see
Managing users and
passwords.
Manage Users and Tasks
Security > Users
No
In SDMC, you can view
running tasks in the Task
Management area of the
GUI.
For more information about
performing this task, see
Managing users and
passwords.
Manage Certificates
CLI: mkcert and updcert
No
CLI only.
For more information about
performing this task, see
Using the SDMC remote
command line.
Configure KDC
Welcome > Settings >
Security Tasks > Configure
Kerberos Client
No
For more information about
performing this task, see
Configuring the SDMC as a
Kerberos client.
Configure LDAP
Welcome > Settings >
Security Tasks > Configure
LDAP Client
No
For more information about
performing this task, see
Configuring the SDMC as
an LDAP client.
Remote Command
Execution
N/A
No
SDMC enables Secure Shell
(SSH) by default. You can
control this only by using
the firewall.
For more information about
performing this task, see
Using the SDMC remote
command line.
Remote Virtual Terminal
N/A
No
SDMC has removed the
remote VTTY port, and
requires SSH instead for
remote console connections.
The SDMC GUI vterm
applet now uses SSH.
Comparing HMC and SDMC features
21
Table 29. HMC (SDMC) management: Administration task mapping (continued)
HMC task
SDMC task
Is the task identical?
Notes
Remote Operation
N/A
No
SDMC enables remote
access to the web interface
by default. You can control
this only by using the
firewall.
For more information about
performing this task, see
Configuring the network.
Change Language and
Locale
CLI: chconfig –l
No
The SDMC GUI can be
controlled with the web
browser locale settings. The
console can be controlled
with only the CLI.
For more information about
performing this task, see
Using the SDMC remote
command line.
Create Welcome Text
N/A
No
There is no equivalent
function in SDMC.
For more information about
performing this task, see
Create welcome text.
Manage Data Replication
N/A
No
There is no equivalent
function in SDMC.
Manage Install Resources
N/A
No
There is no equivalent
function in SDMC.
Service management
This topic provides service management task information for moving from HMC to SDMC.
The following task mapping information is available in this topic:
v Service management task mapping
v Service management: connectivity task mapping
Table 30. Service management task mapping
HMC task
SDMC task
Is the task identical?
Notes
Create Serviceable Event
Welcome > Manage >
Service and Support
Manager > Open a service
request
No
For more information about
performing this task, see
Submitting service request
using Service and Support
Manager.
Manage Serviceable Events
Welcome > Manage >
Service and Support
Manager > Serviceable
Problems
No
For more information about
performing this task, see
Managing serviceable
problems by using Service
and Support Manager.
Manage Remote
Connections
N/A
No
There is no equivalent
function in SDMC.
22
Power Systems: Overview of SDMC
Table 30. Service management task mapping (continued)
HMC task
SDMC task
Is the task identical?
Notes
Manage Remote Support
Requests
N/A
No
There is no equivalent
function in SDMC.
Format Media
N/A
No
There is no equivalent
function in SDMC.
Manage Dumps
Welcome > Manage >
Service and Support
Manager > Manage
Support Files
No
For more information about
performing this task, see
Managing support files by
using Service and Support
Manager.
Table 31. Service management: connectivity task mapping
HMC task
SDMC task
Is the task identical?
Notes
Transmit Service
Information
Welcome > Manage >
Service and Support
Manager > Settings
No
For more information about
performing this task, see
Activating the service and
support manager.
Enable Electronic Service
Agent
Welcome > Manage >
Service and Support
Manager > Settings
No
For more information about
performing this task, see
Activating the service and
support manager.
Manage Outbound
Connectivity
Welcome > Manage >
Service and Support
Manager > Settings
No
For more information about
performing this task, see
Activating the service and
support manager.
Manage Inbound
Connectivity
Welcome > Settings >
Configure VPN
No
Manage Customer
Information
Welcome > Manage >
Service and Support
Manager > Manage your
system contacts
No
For more information about
performing this task, see
Managing serviceable
problems by using Service
and Support Manager.
Authorize User
Welcome > Manage >
Service and Support
Manager > Settings
No
For more information about
performing this task, see
Authorizing user.
Manage Serviceable Event
Notification
Welcome > Manage >
Service and Support
Manager > Settings (click
the learn more about
automation plans link)
No
SDMC supports email
notification only. SNMP
trap notification is not
supported.
Manage Connection
Monitoring
N/A
There is no equivalent
function in SDMC.
Manage POWER4 Service
N/A
There is no equivalent
function in SDMC.
Agent Electronic Service
Agent Setup Wizard
Welcome > Settings >
Serviceability Tasks >
Service and Support
Manager Getting Started
Wizard
Comparing HMC and SDMC features
23
Functional differences between the HMC, IVM, and SDMC
There are functional differences between the Hardware Management Console (HMC) and Integrated
Virtualization Manager environments and the Systems Director Management Console (SDMC)
environment.
The SDMC incorporates most functions of the HMC. This has been done through direct mapping of
commands or by replacing functions that are present already in IBM Systems Director. Some functions are
not currently available for the SDMC, such the ability to handle system plans. For a complete listing of
functions, see Comparing HMC tasks and SDMC tasks
Although the SDMC retains most of the functions that are available in the HMC, a few functional
differences exist between the SDMC and the HMC. These differences are directed toward adapting to the
IBM Systems Director environment and also toward improving the user interface.
The command-line interface (CLI) is essentially the same. On the SDMC, most of the commands are just
preceded by smcli. This might require changes to existing scripts that use the HMC.
Enhanced virtualization management
The following are some of the key enhancements in virtualization management that are available in the
SDMC:
v SDMC offers a simplistic IVM kind of user interface for virtualization functions, such as creating a
virtual server.
v The views of virtual server properties and dynamic logical partitioning (DLPAR) are combined to
present a single view from where you can perform all virtual server operations.
v SDMC provides the ability to change the resource assignment of your virtual servers even when they
are in the Stopped state.
v SDMC can manage virtual slots automatically.
Users and roles
The concepts of users and roles in the SDMC remain the same as in the HMC. The user interfaces for
creating and managing users and roles are different in the SDMC. SDMC follows the IBM Systems
Director way of creating and managing users and roles. SDMC supports the use of LDAP and Kerberos
servers. You can create users who use Lightweight Directory Access Protocol (LDAP) or Kerberos for
authentication. Resource roles in HMC are referred to as groupsin SDMC. Also, the session time-out and
the idle time-out settings are global and not configured per user.
For more information about user and roles in the SDMC environment, see Predefined user IDs and
passwords and SDMC roles
User interface enhancements
SDMC provides a user interface that is integrated with the broader IBM Systems Director user interface.
Most of the tasks in SDMC have the same flow as in the HMC with slight enhancements to present an
IBM Systems Director appearance.
Redundancy model
The existing redundancy model available in HMC is available in the SDMC as well. You can connect two
SDMCs to a managed system in which one of the SDMCs acts as the redundant SDMC. You can also use
an HMC for redundant management. Apart from this redundancy model, IBM Systems Director provides
an active-passive availability model that is optional for the SDMC users. In this model, two SDMC nodes
can manage a single server, of which one node is used (active) and the other is not used (passive),
24
Power Systems: Overview of SDMC
waiting for a failover condition. The existing HMC active-active redundancy model is available in
addition to the active-passive availability model, both provided by the IBM Systems Director.
Backup and Restore
SDMC provides the capability to back up the entire virtual machine to removable media or to a remote
File Transfer Protocol (FTP) server. You can restore using the backup file from the removable media or
from a remote FTP server. The restore operation is a full image deployment and all existing files are
replaced from the backup file. Unlike the HMC, SDMC backs up the entire disk instead of individual
files.
For more information about performing a backup and restore of the SDMC environment, see Backing up
and restoring the SDMC
Additional functions
The SDMC includes the IBM Systems Director base management functions which offers you additional
capabilities to manage your heterogeneous and large homogeneous infrastructure better. These
capabilities include:
v Automation manager
v Update manager
v Status manager
SDMC supported and unsupported systems
Support for POWER processor-based systems with either software or hardware appliance depends on the
type of POWER system you have. This topic provides a complete listing of which appliance is supported
with which system.
Table 32. POWER7 support by SDMC
POWER7 models
Machine types
SDMC
795
9119-FHB
Hardware appliance only
780
9179-MHB
Hardware appliance only
770
9117-MMB
Hardware appliance only
755
8236-E8C
Hardware or software appliance
750
8233-E8B
Hardware or software appliance
720
8202-E4B
Hardware or software appliance
740
8205-E6B
Hardware or software appliance
710/730
8231-E2B
Hardware or software appliance
PS701
8406-71Y
Hardware or software appliance
PS700
8406-70Y
Hardware or software appliance
POWER6 Models
Machine types
SDMC
595
9119-FHA
Hardware appliance only
575
9125-F2A
Hardware appliance only
570
9117-MMA
Hardware appliance only
570
9406-MMA
Hardware appliance only
560
8234-EMA
Hardware appliance only
Table 33. POWER6 support by SDMC
Comparing HMC and SDMC features
25
Table 33. POWER6 support by SDMC (continued)
POWER6 Models
Machine types
SDMC
550
8204-E8A
Hardware or software appliance
550
9409-M50
Hardware or software appliance
520
8203-E4A
Hardware or software appliance
520-SB (IBM Smart Cube)
8261-E4S
Hardware or software appliance
520
9408-M25
Hardware or software appliance
520
9407-M15
Hardware or software appliance
JS23/43
7778-23X
Hardware or software appliance
JS22
7998-61X
Hardware or software appliance
JS12
7998-60X
Hardware or software appliance
Supported configurations
You can connect your SDMC to host systems in a variety of ways.
The following topic describes the different ways you can manage host systems using the SDMC.
Figure 1. SDMC managing multiple Power Systems servers
Figure 2. SDMC managing two different Power systems, where one is managed by an HMC
26
Power Systems: Overview of SDMC
Figure 3. HMC and SDMC managing the same server at the same time
Figure 4. Two SDMCs managing the same server at the same time
SDMC redundancy and high availability features
Implementing SDMC in a high availability (HA) or a redundant setup can provide improved
serviceability to the SDMC appliance and provides backup to the system in case of a disaster.
SDMC HA versus redundant setup
If you are familiar with redundant HMC setup in your Power Systems environment, you can do the same
with SDMC, because multiple SDMCs can connect to and actively manage a single host.
For more information about the tasks associated with SDMC redundancy and high availability, see SDMC
installation and configuration scenarios and Configuring high availability.
You can also implement SDMC HA, which provides active/passive failover capability, with one active
SDMC and one passive SDMC on standby to take over in case of failure.
In addition to providing the management capabilities currently in the HMC for the managed Power
Systems hosts, the SDMC also can manage the operating systems of the hosts themselves by connecting
to the Common Agent Services (CAS) agent on the managed systems through an agent manager.
However, the CAS agent has the limitation of only a single connection to an agent manager and is not
capable of a redundant connection. Therefore, the SDMC HA feature is provided to eliminate this
limitation as a single point of failure if you require high availability for this functionality.
The choice between a redundant setup versus an active/passive HA implementation depends on your
planned usage of the SDMC:
v In an environment where the SDMC is being used for HMC-like management functions, the redundant
setup provides the most availability and is the easiest to set up and administrate. Both SDMCs will be
active and can continue to provide functions for the managed systems should one of them have a
failure. The setup of a redundant SDMC environment only involves adding the managed system to
both SDMCs.
Comparing HMC and SDMC features
27
v For an environment where the SDMC is being used for agent OS management and there is a high
availability requirement for that function, SDMC HA is needed. If your active SDMC fails, the passive
standby SDMC automatically takes over and management functions for the managed systems are
restored in about 10 minutes. Some extra planning, setup, and administrative steps are required to
implement SDMC HA. For more information about the planning tasks associated with implementing
high availability, see Planning for high availability, redundancy, and failover.
The following table shows the differences between redundant HMCs and IBM Systems Director high
availability setup.
Table 34. Differences between a redundant and a replication HA environment
HMC
SDMC with redundancy
Systems Director or SDMC
with HA
Type of environment
Redundant
Redundant
Replication
High availability topology
Active/active: Both
consoles are active at the
same time.
Active/active: Both
consoles are active at the
same time.
Active/passive: Only one
console is active at a time.
Data
Data is not identical.
Data is not identical.
All data is identical on the
two nodes.
Management console
HMC
Systems Director
Systems Director
Console versions
Can be different
Can be different
Must be the same
In a redundant setup, it is also possible to have one SDMC point to another SDMC's agent manager,
which would allow both SDMCs to manage the agents at the same time. However, since the agent
manager is running on only one of the SDMCs, this setup is a single point of failure. If this SDMC goes
down, the other SDMC loses contact with the agents.
Active/passive HA overview
In a high availability environment, two SDMCs operate as synchronized nodes in an active/passive
cluster. One node in the environment is kept active at all times, and a second passive node is kept in
close synchronization. If your active node fails, the passive node (on standby, waiting for a failure of the
active node) takes over in about 10 minutes.
The internal software components that make up SDMC HA are transparent to you and do not need to be
directly configured. Floating IP addresses used to connect to the active SDMC can be moved between the
nodes, by using the active node. The OS on the passive node is started, but the software stack is not.
Running the Guided Setup wizard or the command-line interface commands on the SDMC that is
designated to be the primary node configures the internal HA components on both the primary and
secondary SDMCs.
High availability terminology
Refer to this list of terms to help you better understand high availability concepts:
Node
A node is an SDMC that is configured to be part of a high availability environment.
Active node
An active node manages your environment. Only one node is active at a time.
Passive node
The passive node is not currently active. Any changes you make to the active node are replicated
to the passive node.
28
Power Systems: Overview of SDMC
Primary node
This is the node you use to set up high availability. It is initially the active node. When you set
up a high availability cluster, the IBM Systems Director data, remote authentication configuration
settings, users, and firewall settings on this node are replicated to the secondary node.
Secondary node
This is the node that you set up to take over if the primary node fails. It is initially the passive
node, but takes over as the active node if the primary node is detected to have failed.
Network status IP address
The cluster nodes use this IP address to determine which node is connected to the network. If
they cannot contact each other, the node that can connect to this IP address becomes the active
node.
Floating IP address
This address is always assigned to the active node. Always access this address so that you do not
have to know which node is active. It also enables you to use IBM Systems Director Common
Agent with high availability.
Active/passive HA mirrored directories
The following directories that are replicated and synchronized between the active SDMC and the passive
SDMC in the HA cluster.
Table 35. Replicated and synchronized SDMC directories
Directory
Description
/opt/ibm/director/data
Director data
/home/db2inst1
DB2 data
/opt/ibm/director/keys
License keys
/opt/ibm/director/lwi/conf/overrides
Director property overrides
/opt/ibm/director/lwi/runtime/agentmanager/eclipse/ CAS agent manager config
plugins/com.ibm.tivo li.cas.manager/config
/opt/ibm/director/lwi/runtime/agentmanager/eclipse/ CAS agent manager certificates
plugins/com.ibm.tivo li.cas.manager/certs
/opt/ibm/director/lwi/runtime/core/DATABASE
CAS agent manager database
/opt/ibm/director/lwi/runtime/agentmanager/toolkit/
certs
CAS agent manager toolkit certificates
/opt/ibm/director/lwi/runtime/agentmanager/toolkit/
config
CAS agent manager toolkit configuration files
/var/lib/dhcp
Dynamic Host Configuration Protocol (DHCP) server
config /dump
Flexible service processor (FSP) dump files
/var/hsc/log
SDMC log files
/var/hsc/profiles
Profile files
/opt/hsc/data/utilization
Utilization files
SDMC HA synchronized data
The following data changes on the active SDMC are synchronized to the standby SDMC:
v User ID additions
v User ID modifications
v User ID deletions
Comparing HMC and SDMC features
29
v
v
v
v
Firewall changes
Network Time Protocol (NTP) configuration
Kerberos and Lightweight Directory Access Protocol (LDAP) configuration
Initial HA configuration
– Distributed Replicated Block Device (DRBD) configuration
–
–
–
–
–
–
Users
Authentication files
LDAP and Kerberos
Firewall settings
Domain Name System (DNS) resolver
NTP configuration
SDMC HA processes monitored
The following processes are monitored by the SDMC HA for a redundant takeover:
v Director
v DB2
v DRBD
v CIM server
v HA MQ daemon – MQ server
v HA daemon – Processes MQ messages
v NTP server
v DHCP server
Active/passive HA: Log location
The locations of the HA log files follow:
v /opt/ibm/director/ha/logs/daemon0-x.log
Table 36. daemon0-x.log file description
Log file
Description
daemon0-x.log
HA daemon log
mq0-x.log
ActiveMQ log
smha.log
TSA monitor log
init0-x.log
Initial configuration initiated from outside the Director
process
v /opt/ibm/director/lwi/logs
HA task logs captured in the Systems Director HA configuration task.
v The daemon log and mq log are rolling logs with up to five log files, where x is the log file number.
Each log file can contain approximately 10 MB of data.
SDMC and HMC command-line differences
There are differences between the HMC commands and the SDMC commands.
Commands used to manage the Power Systems servers such as lssyscfg, lshwres, and chhwres that are all
supported and virtually identical to the commands in the HMC. Any scripts that you may have that use
these commands should continue to work with no changes.
30
Power Systems: Overview of SDMC
To see all of the HMC commands that are supported on the SDMC, run the smcli lsbundle command.
The commands that have been carried over from the HMC are in the psm bundle.
The following topic describes how to run SDMC commands. Commands for managing Power Systems
resources can be run in exactly the same way as on an HMC. However, to integrate into the Systems
Director way of doing commands, there are additional ways to issue commands. The following
commands are all equivalent:
v lssyscfg –r sys
v smcli lssyscfg –r sys
v smcli psm lssyscfg –r sys
v The commands that have been carried over from the HMC are aliased. Therefore, you can run the
command in three ways from the command line: lssyscfg, smcli lssyscfg,, or smcli psm lssyscfg .
v Add managed system (mksysconn) in SDMC has been replaced by the smcli discover and smcli
accesssys Systems Director commands.
v Two attributes, primary_state and detailed_state, are introduced to the lssyscfg and lssysconn
commands to indicate the respective Systems Director state mapping. The state field is deprecated. It is
only shown when the -F option is used.
v Man pages for the SDMC commands can be displayed by running either man command_name or man
psm.command_name.
The following tables compare HMC command-line interface (CLI) function with SDMC CLI function.
These tables display only the changes, and all functions not shown can be assumed to be similar.
Table 37. Power Systems management commands
HMC tasks and commands
SDMC commands
Notes
Add Managed System: mksysconn –r
sys/frame
smcli discover –H smcli accesssys
Discover and access are two separate
steps on SDMC. Make sure you
specify the IP or hostname in SDMC;
otherwise, by default, it discovers
everything on your subnet. If SDMC
is acting as the DHCP server, systems
must be automatically discovered.
You must request access.
Remove Managed System: rmsysconn
–o remove
smcli rmsys
You can disconnect by using the
smcli revokeaccesssys command;
however, to completely remove the
system, you must use smcli rmsys.
List system or partition states:
lssyscfg –r sys/lpar –F state
lssyscfg –r sys/lpar –F
primary_state,detailed_state
Although the HMC state option is
supported, to view the states as the
SDMC GUI displays them, you need
to view the primary_state and
detailed_state.
List serviceable events: lssvcevents
smcli lssvcproblem
Table 38. Appliance (SDMC) management commands
HMC tasks and commands
SDMC commands
List and change HMC information
such as version and locale: lshmc /
chhmc
lsconfig / chconfig
List and change HMC network
settings: lshmc –n / chhmc
lsnetcfg / chnetcfg
Notes
Comparing HMC and SDMC features
31
Table 38. Appliance (SDMC) management commands (continued)
HMC tasks and commands
SDMC commands
Notes
Backup and restore console data:
bkconsdata
backup / restore
Hardware appliance only
LDAP configuration: chhmcldap /
lshmcldap
cfgldap / lsldap
Shut down and restart HMC;
hmcshutdown
smshutdown
Create and list HMC users:
ls/mk/ch/rmhmcuser
mksmusr / chsmusr / rmsmusr /
smcli lsuser
Save and restore upgrade data:
saveupgdata / rstupgdata
N/A
This is not needed on SDMC because
the save/restore process happens
automatically as part of an upgrade.
Manage password policies:
mk/ch/ls/rmpwdpolicy
N/A
SDMC does not support password
policy profiles.
Manage access control:
mk/ch/ls/rmaccfg
smcli mk/ch/ls/rmrole
Monitor HMC: monhmc
N/A
Systems Director Management Console limitations
Learn about IBM Systems Director Management Console (SDMC) limitations.
Consider the following limitations when you plan to migrate from Hardware Management Console
(HMC) to SDMC:
v Replication of user data, groups data, LDAP or Kerberos configuration data, and outbound
connectivity configuration data is not supported in SDMC.
v Management of POWER5™ technology-based systems is not supported in SDMC.
v Modem or VPN support for Call home function is not available in SDMC. The Call home function is
supported only on a network connection over SSL.
v Users cannot disconnect and reconnect to old sessions of SDMC.
v No Advanced Manager support in SDMC.
32
Power Systems: Overview of SDMC
Notices
This information was developed for products and services offered in the U.S.A.
The manufacturer may not offer the products, services, or features discussed in this document in other
countries. Consult the manufacturer's representative for information on the products and services
currently available in your area. Any reference to the manufacturer's product, program, or service is not
intended to state or imply that only that product, program, or service may be used. Any functionally
equivalent product, program, or service that does not infringe any intellectual property right of the
manufacturer may be used instead. However, it is the user's responsibility to evaluate and verify the
operation of any product, program, or service.
The manufacturer may have patents or pending patent applications covering subject matter described in
this document. The furnishing of this document does not grant you any license to these patents. You can
send license inquiries, in writing, to the manufacturer.
For license inquiries regarding double-byte character set (DBCS) information, contact the Intellectual
Property Department in your country or send inquiries, in writing, to the manufacturer.
The following paragraph does not apply to the United Kingdom or any other country where such
provisions are inconsistent with local law: THIS INFORMATION IS PROVIDED “AS IS ” WITHOUT
WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO,
THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain
transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors. Changes are periodically
made to the information herein; these changes will be incorporated in new editions of the publication.
The manufacturer may make improvements and/or changes in the product(s) and/or the program(s)
described in this publication at any time without notice.
Any references in this information to websites not owned by the manufacturer are provided for
convenience only and do not in any manner serve as an endorsement of those websites. The materials at
those websites are not part of the materials for this product and use of those websites is at your own risk.
The manufacturer may use or distribute any of the information you supply in any way it believes
appropriate without incurring any obligation to you.
Licensees of this program who wish to have information about it for the purpose of enabling: (i) the
exchange of information between independently created programs and other programs (including this
one) and (ii) the mutual use of the information which has been exchanged, should contact the
manufacturer.
Such information may be available, subject to appropriate terms and conditions, including in some cases,
payment of a fee.
The licensed program described in this document and all licensed material available for it are provided
by IBM under terms of the IBM Customer Agreement, IBM International Program License Agreement,
IBM License Agreement for Machine Code, or any equivalent agreement between us.
Any performance data contained herein was determined in a controlled environment. Therefore, the
results obtained in other operating environments may vary significantly. Some measurements may have
been made on development-level systems and there is no guarantee that these measurements will be the
© Copyright IBM Corp. 2011
33
same on generally available systems. Furthermore, some measurements may have been estimated through
extrapolation. Actual results may vary. Users of this document should verify the applicable data for their
specific environment.
Information concerning products not produced by this manufacturer was obtained from the suppliers of
those products, their published announcements or other publicly available sources. This manufacturer has
not tested those products and cannot confirm the accuracy of performance, compatibility or any other
claims related to products not produced by this manufacturer. Questions on the capabilities of products
not produced by this manufacturer should be addressed to the suppliers of those products.
All statements regarding the manufacturer's future direction or intent are subject to change or withdrawal
without notice, and represent goals and objectives only.
The manufacturer's prices shown are the manufacturer's suggested retail prices, are current and are
subject to change without notice. Dealer prices may vary.
This information is for planning purposes only. The information herein is subject to change before the
products described become available.
This information contains examples of data and reports used in daily business operations. To illustrate
them as completely as possible, the examples include the names of individuals, companies, brands, and
products. All of these names are fictitious and any similarity to the names and addresses used by an
actual business enterprise is entirely coincidental.
COPYRIGHT LICENSE:
This information contains sample application programs in source language, which illustrate programming
techniques on various operating platforms. You may copy, modify, and distribute these sample programs
in any form without payment to the manufacturer, for the purposes of developing, using, marketing or
distributing application programs conforming to the application programming interface for the operating
platform for which the sample programs are written. These examples have not been thoroughly tested
under all conditions. The manufacturer, therefore, cannot guarantee or imply reliability, serviceability, or
function of these programs. The sample programs are provided "AS IS", without warranty of any kind.
The manufacturer shall not be liable for any damages arising out of your use of the sample programs.
Each copy or any portion of these sample programs or any derivative work, must include a copyright
notice as follows:
© (your company name) (year). Portions of this code are derived from IBM Corp. Sample Programs. ©
Copyright IBM Corp. _enter the year or years_.
If you are viewing this information in softcopy, the photographs and color illustrations may not appear.
Trademarks
IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business
Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be
trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at
Copyright and trademark information at www.ibm.com/legal/copytrade.shtml.
Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both.
Other product and service names might be trademarks of IBM or other companies.
34
Power Systems: Overview of SDMC
Terms and conditions
Permissions for the use of these publications is granted subject to the following terms and conditions.
Personal Use: You may reproduce these publications for your personal, noncommercial use provided that
all proprietary notices are preserved. You may not distribute, display or make derivative works of these
publications, or any portion thereof, without the express consent of the manufacturer.
Commercial Use: You may reproduce, distribute and display these publications solely within your
enterprise provided that all proprietary notices are preserved. You may not make derivative works of
these publications, or reproduce, distribute or display these publications or any portion thereof outside
your enterprise, without the express consent of the manufacturer.
Except as expressly granted in this permission, no other permissions, licenses or rights are granted, either
express or implied, to the publications or any information, data, software or other intellectual property
contained therein.
The manufacturer reserves the right to withdraw the permissions granted herein whenever, in its
discretion, the use of the publications is detrimental to its interest or, as determined by the manufacturer,
the above instructions are not being properly followed.
You may not download, export or re-export this information except in full compliance with all applicable
laws and regulations, including all United States export laws and regulations.
THE MANUFACTURER MAKES NO GUARANTEE ABOUT THE CONTENT OF THESE
PUBLICATIONS. THESE PUBLICATIONS ARE PROVIDED "AS-IS" AND WITHOUT WARRANTY OF
ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED
WARRANTIES OF MERCHANTABILITY, NON-INFRINGEMENT, AND FITNESS FOR A PARTICULAR
PURPOSE.
Notices
35
36
Power Systems: Overview of SDMC
Printed in USA