Installation and Safety Instructions IP44 Recessed Downlight 240V

Installation and Safety Instructions IP44 Recessed Downlight 240V
Installation and Safety Instructions
IP44 Recessed Downlight
240V GU10
41341
67764
78571
These instructions are for your safety. Please read through them thoroughly before use
and retain for future reference.
Tools Required (not supplied)
3mm Flat Blade Screwdriver
6mm Cross Headed Screwdriver
Power Drill
66mm Hole Saw / Keyhole Saw
File
Pencil
Sundries / Extras (not supplied)
Insulating Tape
Terminal block
GU10 Lamp Max. 50W
Before You Start
•
•
•
•
If you need any assistance please contact your local trade counter who will be able to help
you.
Decide on an appropriate location for your product (see siting instructions below).
This product is not suitable for single-handed installation. An assistant will be required
during fitting.
If you are in any doubt about installing this product, consult a qualified electrician.
Siting Instructions
1) This product is suitable for indoor use only.
2) Do not attach to surfaces which are damp, freshly painted or otherwise electrically conductive
(e.g. metallic surfaces).
3) This fitting is not suitable for direct mounting on normally flammable surfaces,
e.g wood based materials. It is suitable only for mounting on non-combustible
surfaces e.g plasterboard, masonry. Shown by the symbol on the right.
4) The lamp must be positioned so that there is at least 0.5m between the bulb and any illuminated
surface (see Fig.A below). Spotlights should be positioned well away from curtains and beds to
ensure this distance is maintained.
5) This product is specially designed for installation in a bathroom. It is IP44 rated and can be
fitted in Zone 2 and Outside (dry) zones of a bathroom - see diagram below.
6) The bezel on this product provides the IP44 protection. The electrical parts of this product must
be installed in a fully enclosed ceiling void with the bezel fitted to maintain the IP44 rating. Do not
use the product without the bezel fitted.
Fig .A
0.5m
0.5m
CORRECT
Window
recess
LESS THAN
0.5m
INCORRECT
Page 1 of 4
7) If fitting in a bathroom this product must be supplied via a 30mA Residual Current Device
(RCD) and installed by a competent person in accordance with the IEE wiring regulations BS7671
and local Building regulations.
8) Expert advice should be sought before installing downlighters in any ceiling forming a fire
barrier e.g. ceilings between flats etc.
Hole Diameter: Minimum Ceiling Cavity Depth:
Ceiling Preparation
66MM
140MM
1) Ensure a minimum depth of ceiling void of 140mm is available. See fig 1 on page 3.
2) When more than one down light is to be installed, the distance between units must be at least
0.3m (30cm).
3) Cut the 66mm diameter mounting holes in the ceiling taking care not to foul any pipes, mains
cables or joists beneath the surface.
4) All measurements are based on a ceiling with a 12mm thickness. If your ceiling thickness
is less than 12mm, deduct approximately 5mm from the ceiling diameter shown above. If the
ceiling is thicker than 12mm, gradually increase the hole until a snug fit is achieved. It is always
recommended to cut the hole slightly smaller than the size specified, and then file the hole until the
recessed unit fits snugly.
5) Ensure free movement of air around the fitting by removing any roof void insulation
from at least 100mm around the hole. Under no circumstances must these fittings be
covered with insulating matting or similar material.
WIRING
*Refer to Electrical change sheet for old and new wiring cable colours IMPORTANT.
Always switch off the electricity supply at the mains during installation and maintenance. We
recommend that the fuse is withdrawn or circuit breaker switched off at the distribution board whilst
work is in progress (turning off the lightswitch is not sufficient). All fittings must be installed by a
competent person in accordance with current IEE Wiring Regulations (BS7671) and local Building
Regulations. If in doubt, consult a qualified electrician.
These fittings can be connected in star or parallel configurations. See diagram below.
1) Draw the mains cable through the hole in the ceiling. (Use minimum 1.0 mm2 core cable
H03VV-F or equivalent).
2) Open terminal block box by loosening screw. Loosen screws on cable clamp and fit supply
wiring into cable clamp. (See Fig. 2)
3) Connect supply cable to the terminal box attached. Live supply to the Brown input cable and neutral
supply to the Blue input cable. (See Fig. 3) Terminate your Earth and Loop cables as necessary. Refit
terminal block cover and tighten screw.
4) Fit terminal block bracket to downlight by sliding end of bracket into spring coil. (See Fig. 4)
5) Check all connections are tight. Tighten cable clamp screw.
These units are double insulated and must not be earthed. If there are any incoming earth cables, they
must be joined together and well insulated with good quality insulation tape. This is to ensure earth
continuity throughout your property.
6) This product is suitable for use with dimmer switches when fitted with a halogen bulb.
Star Wiring
Mains
Input
Recessed Unit
Schematic
L
N
Parallel Wiring
Schematic
L
N
Mains
Input
Recessed Unit
Page 2 of 4
Installation
Ensure the ceiling surface is flat and smooth to ensure a good seal.
1) Always switch off or disconnect from the mains before installation.
2) Feed the supply cable through the mounting hole. Squeeze the spring clips upwards towards
the ceiling and fit the arms into the ceiling hole (See below.) Take care when releasing your grip
as the springs will snap back and push against the back of the ceiling.
3) Ensure the cable is kept away from the lamp body to ensure it is not subjected to excess heat
from the lamp.
4) Push the unit upward until firmly in position, ensuring that the cable is not trapped.
5) Remove front bezel by pulling away.
6) Obtain a suitable bulb - 50W Max GU10 Halogen or equivalent energy saving LED or
compact Fluorescent GU10 bulb. See “Bulb replacement” section below on how to fit.
7) Replace the circuit fuse and switch on the mains to test.
Fig. 1
140mm
300mm
150mm
Fig. 2
Fig. 3
L
L
N
Fig. 4
Fig. 5
Fig. 6
N
Bulb replacement
1) Switch off and allow bulb to cool before replacing.
2) Pull-off front bezel to expose bulb. (Fig. 5) Unclip bulb from bezel. (Fig. 6)
3) Remove old bulb by holding lampholder and turning bulb anticlockwise a quarter turn.
Replace with bulb type 50W MAX. GU10 Halogen. Only use self-shielded halogen bulbs
marked with the symbol shown on the right. Alternatively, use equivalent energy saving
LED or Compact Fluorescent GU10 bulb.
4) Fit the new bulb into the lampholder, slide into bezel and refit bezel back onto product. Ensure
bezel is securely fitted to maintain water-tight seal.
Care & Use
•
•
•
Always switch off or disconnect from the mains when cleaning the product.
Wipe clean with a soft dry cloth. Never use scourers, abrasives or chemical cleaners. Do
not allow moisture to come into contact with electric parts.
If the glass shield becomes cracked or damaged it must be replaced. Do not use the
product without front bezel attached.
Powersmith Ltd, BA22 8RT
160611
Replace Cracked
Shade
Page 3 of 4
Important- Electrical Changes
Please Read
Changes to Building Regulations
As of 1 January 2005, changes to the Building Regulations affected domestic electrical installations in England and
Wales. You don’t need to be a qualified electrician to make changes to your home’s electrical system, but the work
must be done in accordance with the standards in the Regulations.
You do not need to notify your Local Authority if you do minor electrical work such as:•
replacing or repairing a socket, light or cable in any room
•
adding extra spurs, sockets or lights to an existing circuit (except in a kitchen, bathroom or outdoors)
•
adding lights to an outdoor wall on an existing circuit (provided there are no exposed outdoor connections,
and the circuit is not extended from a kitchen/bathroom).
However, the work must be done to the standards in the Wiring Regulations and you should consider having the work
checked by a competent electrician to make sure it is safe.
Before you start other electrical work such as:•
adding new circuits to your existing installation
•
any work (other than repairs / replacements) in a room where there is water (e.g. kitchen, bathroom, etc.)
•
any work (other than repairs / replacements) outdoors (e.g. installing outdoor sockets, or non-pre-wired garden lighting etc.)
you must notify your Local Authority Building Control Department, which has responsibility for ensuring the work is
inspected and tested.
Where you have any work done by an electrician who is a member of a competent person self-certification scheme,
the electrician will be able to certify the work complies with the Regulations and you do not need to notify your Local
Authority.
We recommend that you make yourself aware of the Regulations before you undertake any work and if you require
any clarification you should contact your Local Authority Building Control Department.
Changes to Wiring Cable Colours in UK
The IEE Wiring Regulations (BS 7671) have changed the colours in cable used for fixed wiring for all new electrical
installations.
The old and the new colours are shown in the table below.
OLD
Core colour
NEW
LIVE
Red
Brown
SWITCHED LIVE
Red, or
Black with red sleeve
Brown, or
Blue with brown sleeve
NEUTRAL
Black
Blue
EARTH
Bare, with green/yellow sleeve Bare, with green/yellow sleeve
(no change)
2-WAY SWITCHED LIVE
Red, blue and yellow
Brown, black and grey
For new installations after 31st March 2006, only the new colours are permitted. Where new cable is added to an
existing installation of the old type, special precautions must be taken (including fixing a warning notice at the distribution board or consumer unit).
When installing this product, please note therefore that you may encounter either of the above types of cable.
If you are in any doubt whatsoever regarding the above, please consult a qualified electrician.
Page 4 of 4