lbi-39045 - power distribution panel 19d904180g5

lbi-39045 - power distribution panel 19d904180g5
LBI-39045
MAINTENANCE MANUAL
POWER DISTRIBUTION PANEL
19D904180G5
P
O
W
E
R
TABLE OF CONTENTS
Page
SPECIFICATIONS ...........................................................................................................................
1
DESCRIPTION .................................................................................................................................
POWER DISTRIBUTION .........................................................................................................
PIN-TO-PIN WIRING AND COLOR CODING ......................................................................
1
2
2
ILLUSTRATION
Figure 1 − DVIU Power Distribution Block Diagram ...............................................................
3
ASSEMBLY DIAGRAM ..................................................................................................................
4
PARTS LIST .....................................................................................................................................
5
D
I
S
T.
P
A
N
E
L
SPECIFICATIONS*
MECHANICAL
Length
Standard 19-inch rack mount
Height
2 rack units (3.5 inches)
Depth
2.75 inches
INPUT CONNECTIONS
Total Connectors
Connector Type
PANEL-TO-PANEL JUMPER CONNECTIONS
Total Connectors
Connector Type
one (J1)
AMP 641685-2 four position connector
two (J2 and J3)
AMP 350782-1 nine position connectors
OUTPUT CONNECTIONS
*
Total Connectors
thirteen (J4 - J16; DVIU uses J4 - J11 only)
Connector Type
AMP 350767-1 four position connectors
These specifications are intended primarily for the use of the serviceman. See the appropriate Specifications Sheet for complete specifications.
DESCRIPTION
fully loaded DVIU cabinet requires two (2) Power
Distribution Panels.
Power Distribution Panel 19D904180G5 is used in the
Digital Voice Interface Unit (DVIU) cabinet to provide dc
power interconnections between the Redundant Power
Supply (RPS) unit and the DVIUs within the cabinet. A
Each panel distributes the +5 and ±12 Vdc power from
the RPS unit to the eight (8) DVIUs directly above it. Panel
1 serves DVIUs 1 - 8 and Panel 2 serves DVIUs 9 - 16.
1
LBI-39045
The panels mount on the cabinet's rear mounting rails.
See the Application Assembly Diagram in LBI-39041 for
additional rack-up details.
PIN-TO-PIN WIRING
AND COLOR CODING
POWER DISTRIBUTION
Table 1 identifies the pin-to-pin wiring pattern and the
wire color coding scheme used within the Power
Distribution Panel. This same color coding scheme is
followed in all power interconnecting cables within the
DVIU cabinet.
As shown in Figure 1, dc power from the RPS unit
enters the Power Distribution Panel at connector J1 via
Power Cable 344A4677P60. From this point, the power is
distributed to the eight (8) DVIUs that the panel serves via
connectors J4 - J11 and Power Cables 344A4677P40.
If the DVIU cabinet is equipped with nine (9) or more
DVIUs, a second Power Distribution Panel (Panel 2) is
installed in the DVIU cabinet to serve the second group of
eight DVIUs. Power for this second panel is not applied
directly from the RPS unit. Instead, a power "jumper" cable
jumps the +5 and ±12 Vdc power lines from the first panel
to the second panel. Specifically, this is achieved via
connectors J2 at each panel and Power Cable
344A4677P52.
NOTE
The 5 Vdc remote voltage sense leads from the
RPS unit are not routed through the Power
Distribution Panels. These leads, within Cable
344A4677P60, terminate at J1 on the first Power
Distribution Panel (Panel 1). The +5V sense lead
(brown) terminates at J1 pin 4 and the -5V or
return sense lead (white) terminates at J1 pin 3.
TABLE 1 - POWER DISTRIBUTION PANEL 19D904180G5
PIN-TO-PIN WIRING LIST AND COLOR CODING
J1
PIN NUMBER
(Input
Connector)
J2 & J3
PIN NUMBER(S)
(Panel-To-Panel
Jumper Connectors)
J4 - J16
PIN NUMBER
(Output Connectors)
BUS BAR
MARKING
USE
WIRE
COLOR
1
1
1
-12V
-12 Vdc
Blue
2
2, 3, 4
2
+12V
+12 Vdc
Orange
3*
7, 8, 9
3
GND
Ground
Black
4*
5, 6
4
+5V
+5 Vdc
Yellow
*
See above NOTE for 5 Vdc remote voltage sensing information.
Ericsson GE Mobile Communications Inc.
Mountain View Road • Lynchburg Virginia 24502
Copyright January 1994, Ericsson GE Mobile Communications, Inc.
2
Printed in U.S.A.
BLOCK DIAGRAM
LBI-39045
P
O
W
E
R
D
I
S
T.
P
A
N
E
L
Figure 1 − DVIU Power Distribution Block Diagram
3
LBI-39045
POWER DISTRIBUTION PANEL
19D904180G5
(Made From 19D904180 Sh. 5, Rev. 0)
4
ASSEMBLY DIAGRAM
PARTS LIST
LBI-39045
POWER DISTRIBUTION PANEL
19D904180G5
ISSUE 1
SYMBOL
PART NUMBER
P
O
W
E
R
DESCRIPTION
- - - - - - - - - - - JACKS - - - - - - - - - J1
J2
and
J3
344A4964P130
Cable, power. Includes:
344A3804P2
Connector housing: sim to AMP 641685-2.
344A3805P1
Terminal: sim to AMP 350650-1. (Qty = 4)
344A4964P140
Cable, power. Includes:
D
I
S
T.
Connector housing: sim to AMP 350782-1
Terminal, female: sim to AMP 350874-3 or
350919-3. (Qty = 9)
J4
thru
J16
344A4964P120
Cable, power. Includes:
Connector housing: sim to AMP 350767-1
P
A
N
E
L
Terminal, female: sim to AMP 350874-3 or
350919-3. (Qty = 9)
- - - - - - - MISCELLANEOUS - - - - - - 8
N80P13005B6
Machine screw, panhead: No. 6-32 x 5/16.
11
19A702381P408
Tap screw, TORX Drive, M3-0.5 x 8.
12
5490407P45
Grommet, rubber.
20
19D904159P2
Cover, steel.
21
19B802376P2
Busbar, steel.
22
19B802469P2
Spacer, nylon: 0.5 inch length, No. 6-32 threads
23
19B209137P3
Terminal, quick disconnect; sim to Zerick 929130-FOUR
25
19D904129P5
Panel, steel.
5
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project