Starfire Water IV
Up to 86% AFUE Oil Fired Hot Water Boiler
• Available in 9 sizes from 103 MBH to 252 MBH.
• Dependable Cast Iron Heat Exchanger with Cast Iron Push
Nipples. The Sections and Push Nipples expand at the same rate
when heated. By using similar materials instead of less expensive
gaskets the boiler maintains a water tight seal over time.
• Honeywell 2012 Compliant High Limit and Circulator Relay Control.
- Digital temperature display and diagnostics.
- Less Coil: Control monitors water temperature and delays the burner
starting until any residual heat has been transferred. Thermal purge
logic measures rate of temperature change inside the boiler and
delays burner firing accordingly. This maximizes efficiency by turning
on the burner only when needed.
- With Coil: The Boiler utilizes a Honeywell non-thermal purge High
Limit, Low Limit and Circulator Relay control.
• Atmospheric Chimney Vent Boiler.
• Optional Tankless Heater Coil.
• Textured paint Jacket.
• Limited Lifetime Warranty (Residential Applications).
• Made in the U.S.A.
Utica Starfire IV Residential Oil Fired Water Boiler
Dimensional Diagram
Front View
Net AHRI
Ratings (2) (4) Min. Natural Draft AFUE %
Chimney Size
Water MBH
G.P.H.
MBH(4)
Heating
Capacity
MBH (4)
SFH-3085W*
0.85
119
103
90
8”x8”x15’
SFH-3100W
1.00
140
119
103
8”x8”x15’
SFH-4100W*
1.00
140
122
106
8”x8”x15’
SFH-4125W*
1.25
175
151
131
8”x8”x15’
SFH-4145W
1.45
203
173
150
8”x8”x15’
SFH-5160W*
1.60
224
193
168
8”x8”x15’
SFH-5185W
1.85
259
221
192
8”x8”x15’
SFH-6175W*
1.75
245
212
184
8”x8”x15’
SFH-6210W
2.10
294
252
219
8”x8”x15’
Model
(1)
AHRI Oil Burner Input (1)
85.0%
84.0%
86.0%
85.0%
84.0%
85.0%
84.0%
85.0%
84.0%
* Indicates an ENGERYSTAR rated product.
(1) AHRI burner capacity is based on an oil heating value of 140,000 Btu/gal and with 13% CO2.
(2) Net AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15.
(3) Consult manufacturer before selecting boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping.
(4) For forced hot water heating systems where boiler and all piping are within the area to be heated, select boiler on basis of its Heating Capacity.
General Information (See Installation, Operation and Maintenance Manual for complete instructions)
Clearances
Required
distances
measured from
boiler.
Combustible Materials (Required)
Top
24" (610 mm)
Sides
6" (152 mm)
Front
24" (610 mm)
Back
6" (152 mm)
Flue Connector
9" (229 mm)
Connections
(All Models)
Supply Tapping - 2", Return Tapping 1-1/2" NPT, Oil Line 3/8" O.D. copper tubing for runs of 50 feet or
less, and ½" O.D. for longer runs.
Electrical
120 Volts AC, 60 hertz, 1 phase, Less than 12 amps (15 amp circuit recommended).
Model
Side View
Tankless
Heater
Capacities
Dimensions/
Weights
Standard
Equipment
Options
SFH-3085WT
SFH-3100WT
SFH-4100WT
SFH-4125WT
SFH-4145WT
SFH-5160WT
SFH-5185WT
SFH-6175WT
SFH-6210WT
Input Rate
G.P.H.
0.85
1.00
1.00
1.25
1.45
1.60
1.85
1.75
2.10
Tankless Heater
Number
T3
T3
T4
T4
T4
T4
T4
T4
T4
No. of
Sec.
A
(Depth of Flush Jacket)
3
4
5
6
17-7/8"
21-1/2"
25-1/8"
29-1/4"
Tankless Heater Capacity
Boiler Water
Intermittent Draw G.P.M.
Content (Gallons)
3
10.5
3-1/4
10.5
3-1/4
13.5
3-3/4
13.5
4
13.5
4
16.5
4-1/4
16.5
4-1/4
19.5
4-1/2
19.5
B
C
(Front of Jacket to Center
Weight
(Flue Outlet Diameter)
Line of Flue Outlet)
11-3/4"
12-5/8"
14-1/4"
15-15/16"
6"
6"
7"
8"
534 lbs.
668 lbs.
781 lbs.
901 lbs.
Boiler Controls: Primary Control, High Limit and Circulator Control
Heat Exchanger: Cast Iron Heat Exchanger with Cast Iron Push Nipples. Swing out Burner Door.
Combustion: Oil Burner, Target Wall/Liner.
Electrical: Wiring Harness, Burner Electrical Disconnect.
Other: Crated Boiler, Flush Jacket, Circulator- 1¼", Supply Tapping-2", Return Tapping-1 1/2", Temperature
Pressure Gauge, Safety Relief Valve, Drain Valve.
For Tankless Heater Units add Tankless Hot Water Coil and Triple Combination High Limit/Low Limit/Circulator
Control.
Taco, Grundfos or Less Pump; Tankless Coil.
Certifications
Tested for 75 psi ASME
Working Pressure
All ratings and specifications subject to change.
Contractor
Assistance: 800.325.5479
PN 240009798 Rev. 10/12
P.O. Box 4729
Utica, New York 13504
tel: 315.797.1310 • fax: 315.797.3762
www.uticaboilers.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising