GRAFIK Eye® QS Control Unit Mechanical Dimensions

GRAFIK Eye® QS Control Unit Mechanical Dimensions
100 V
Preset Dimming Controls
Control Unit
369430 Rev. A 1 04.25.11
GRAFIK Eye® QS Control Unit
Open
1
Preset
2
Close
3
Description
GRAFIK Eye® QS is the premier energy-saving light
and shade control. GRAFIK Eye® QS includes an
astronomic timeclock, intuitive lighting presets, and
direct shade control. Additionally, the GRAFIK Eye® QS
is compatible with all Lutron wired QS products and
systems, including Quantum®.
4
Off
LUTRON
Mechanical Dimensions
94 in
(239 mm)
4 in
(10 mm)
2 in
(51 mm)
4$ in
(119 mm)
Front View
Side View
Fits into a 4-gang U.S. backbox, 3` in (89 mm) deep; Lutron P/N 241-400.
System Topology
Example of Wired System
Wired QS link
GRAFIK Eye® QS
GRAFIK Eye® QS
LUTRON
LUTRON
LUTRON
Quantum®
(optional)
seeTouch®
QS
seeTouch®
QS
QSE-CI-NWK-E
Wired
occupancy
sensor
®
Job Number:
LUTRON
QS Sensor
Module
Energi Savr NodeTM
SPECIFICATION SUBMIT T A L
Job Name:
Sivoia® QS
shade
Model Numbers:
Page 1
100 V
Control Unit
Preset Dimming Controls
369430 Rev. A 2 04.25.11
Open
1
Preset
2
Close
3
Features
• Pushbutton recall of four preset lighting
scenes, plus Off.
• Twelve (12) additional scenes accessible
through other QS devices, such as seeTouch®
QS wallstations.
• Optional integrated shade control buttons,
which can also be added to the unit after
installation.
• Master override buttons to raise and lower all
lights.
• Allows setup of lighting scenes and shade
presets using buttons on the control unit.
• Built-in infrared (IR) receiver.
• External IR connection.
• Built-in astronomic timeclock.
• Info screen shows zone light level percentage,
energy savings, zone labeling, and
programming.
• Lockout option prevents accidental changes.
• One occupancy sensor input and 24 V
power for occupancy sensor.
• QS communication link for seamless
integration of lights, motorized window
treatments, occupancy sensors, wallstations,
and integration interfaces.
• Compatible with all Lutron QS system
components.
• Backlit buttons with engraving make unit easy
to locate and operate.
• Available in a variety of colors and finishes.
4
Off
LUTRON
Note: General Engraving (-EGN) shown.
1
2
3
4
5
6
OK
Open
1
Preset
2
Close
3
4
Off
USB type
mini B
Optional
shade control
keypad
®
Zone
control
Infrared
receiver
Lighting
control
keypad
SPECIFICATION SUBMIT T A L
Job Name:
Job Number:
Model Numbers:
Info
screen
Page 2
100 V
Control Unit
Preset Dimming Controls
369430 Rev. A 3 04.25.11
Specifications
Input Power
• 100 V 50/60 Hz
Environment
• 32 to 104 °F (0 to 40 °C).
• Relative humidity less than 90% non-condensing.
Lighting Sources/Load Types
Controls the following lighting sources with a smooth,
continuous square law dimming curve or on a full
conduction non-dim basis:
• Incandescent
• Halogen
• Magnetic low-voltage transformer
• Neon and cold cathode
• Non-dim (incandescent, magnetic low-voltage,
or neon/cold cathode)
Please refer to “Capacities” for more information.
Controls the following lighting sources with a smooth,
continuous square law dimming curve or on a full
conduction non-dim basis through separate Lutron power
interfaces:
• Electronic low-voltage transformer
• Non-dim
• 0 - 10 V
Capacities
100 V
Unit Capacity (watts)
MLV
50 / 60 Hz
1600
1600 VA / 1200 W
Zone Capacity (watts)
MLV
25 – 600
25 – 600 VA / 25 – 480 W
Load Type Notes
• All electronic low-voltage (ELV) lighting used with an
interface must be rated for reverse phase control
dimming. Before installing an ELV light source, verify with
the manufacturer that their transformer can be dimmed.
When dimming, an ELV interface (such as the PHPM-PADV-WH) must be used with the control unit.
• Not all zones must be connected; however, connected
zones must have a minimum load as specified above.
• No zone may be loaded with more than the capacity
specified above. For higher wattage applications, use
Lutron power module PHPM-PA-JA or PHPM-SW-JA.
Key Design Features
• Lightning strike protection meets ANSI/IEEE standard
62.41-1980. Can withstand voltage surges of up to
6000 V
and current surges of up to 3000 A.
• Tested to withstand 16 kV electrostatic discharge
without damage or memory loss.
• RTISSTM-equipped: Compensates in real time for
incoming line voltage variations (no visible flicker with
+/-2% change in RMS voltage per cycle, and +/-2% Hz
change in frequency per second).
• Power failure memory retains programming and light
level settings for up to 10 years in the event of a power
loss.
• The GRAFIK Eye® QS supplies 3 Power Draw Units
(PDUs) on the QS link.
For complete information, see “Power Draw Units on
the QS Link,” Lutron PN 369405.
• Faceplate is hinged at the top and bottom, and stays
open at 180° for ease of access.
Scene and Shade Buttons
• Large, rounded buttons are easy to use.
• Backlit buttons with optional engraving make it easy
to find and to operate the control unit in low light
conditions (backlight can be disabled).
• Optional button engraving is angled up to the eye for
easy reading.
• Predefined label stickers are included for field labeling.
• 4 preset lighting scenes, plus Off, are accessible from
the front of the control unit.
• 12 additional scenes are stored in the control unit and
are accessible from seeTouch® QS wallstations and
QS interfaces.
• Light levels fade smoothly between scenes. Fade time
can be set differently for each scene: 0 to 59 seconds,
or 1 to 60 minutes. Maximum fade time from Off is
3 seconds.
System Limits
• The QS wired communication link is limited to 100
devices or 100 zones.
®
SPECIFICATION SUBMIT T A L
Job Name:
Job Number:
Model Numbers:
Page 3
100 V
Control Unit
Preset Dimming Controls
369430 Rev. A 4 04.25.11
Specifications
Shade Control
• The GRAFIK Eye® QS can include up to 3 shade button
columns. Each column has backlit open, preset, close,
and raise/lower buttons.
• Each shade button column can be programmed to
operate one shade or a group of shades. (Shades may
be assigned to more than one shade button column).
• Faceplates are available with 1, 2 and 3 shade button
columns.
Zone Control
• Each zone has a dedicated raise and lower button to
adjust the zone.
• Each zone has a dedicated 7 LED bar graph for level
status. Percentage of light level and energy saved is
displayed on the info screen.
• All zone information has blue backlit LEDs. Backlight
turns off when idle for 30 seconds.
Info Screen
• OLED (organic LED) screen is viewable from all angles.
• Screen turns off when idle for 30 seconds.
• Programmable zone labels.
• Programmable scene labels.
• Status of real-time zone percentage and energy savings.
• Programmable timeclock schedules.
• Programmable shade labels.
Astronomic Timeclock
• Integral to all units.
• 7 daily schedules available.
• One available holiday schedule is programmable by
date up to one year in advance.
• 25 events per day maximum.
• Timeclock events are programmable to control scenes
that affect any Energi Savr NodeTM unit connected on
the QS link without changing the local scene on the
GRAFIK Eye® QS.
• Astronomic times are programmable by integral city
database or by entering latitude and longitude. Times
automatically adjust throughout the year based on
location.
• Local timeclock events can activate any of the following
features:
- Scenes 1 to 16 and Off
- Any available shade presets
- Start and End afterhours mode
- Enable and Disable daylighting for all zones/groups
- Enable and Disable occupancy for occupancy/
vacancy sensors
- Enable and Disable occupied events for all occupancy
sensors
System Communications and Capacities
• Low-voltage type IEC PELV/NEC® Class 2 wiring
connects control units, wallstations, motorized shades,
and control interfaces.
• A QS system can have up to 100 devices and 100
zones.
Infrared
• Infrared (IR) receiver allows infrared transmitters to
select 8 scenes, raise/lower lighting zones, or raise/
lower shades.
• Transmitter buttons imitate buttons on faceplate.
• 50 ft (15 m) line of sight range.
• Terminal block infrared input for connection to a wired
IR input from third-party equipment.
• IR can be disabled via programming.
• Works with Lutron GRX-IT and GRX-8IT infrared remote
controls.
®
SPECIFICATION SUBMIT T A L
Job Name:
Job Number:
Model Numbers:
Page 4
100 V
Control Unit
Preset Dimming Controls
369430 Rev. A 5 04.25.11
Specifications
Accessory Controls: seeTouch® QS Wallstations
(QSWS2)
• Wired seeTouch® QS keypads provide the following
features:
- Access to one or more of the 16 scenes on the
GRAFIK Eye® QS
- Zone toggle, partitioning, sequencing, fine tune, panic
mode, and timeclock enable/disable
- Contact closure inputs
- Certain functions are only available on specific
wallstation configurations. Refer to the seeTouch QS
specification submittal.
Accessory Controls: QS Sensor Module (QSMX-4W)
• The QS Sensor Module provides a means to link wired
occupancy and daylight sensors to a GRAFIK Eye® QS
via the wired QS link.
- Occupancy sensors wired to a QS Sensor Module can
be used by one or more GRAFIK Eye® QS control units
on the wired link.
- Daylight sensors wired to a QS Sensor Module can be
used by one or more GRAFIK Eye® QS control units on
the wired link.
- Infrared sensors can control either one or more zones
or scenes on the GRAFIK Eye® QS. Functionality varies;
refer to the documentation for the QS Sensor Module
for details.
Accessory Controls: Contact Closure Input/Output
Interface (QSE-IO)
• Recalls preset light levels for the following set of scenes
on the GRAFIK Eye® QS:
Scenes 1-4 and Off Scenes 9-12 and Off
Scenes 5-8 and Off Scenes 13-16 and Off
• Sequence scenes 5-16, Enable/Disable Zone Lockout,
Enable/Disable Scene Lockout, Enable/Disable Panic
Mode, Enable/Disable Timeclock.
• Occupancy Sensors. An individual input counts as 1
occupancy sensor for the GRAFIK Eye® QS. Each input
can be assigned to either Scene Control or Zone Control
(please refer to the Occupancy Sensor(s) section of this
guide).
• Zone Toggle. Allows an input to toggle one or more
zones to a preset level and off.
• Shade Output mode. A Shade Column on the GRAFIK
Eye® QS can be linked to control outputs 1-3 and/or
outputs 4-5 on the QSE-IO.
®
SPECIFICATION SUBMIT T A L
Job Name:
Job Number:
Model Numbers:
Accessory Controls:
DMX Output Interface (QSE-CI-DMX)
• Any zone on the GRAFIK Eye® QS control unit can be
mapped to any single DMX512 Channel.
• Any zone on the GRAFIK Eye® QS control unit can be
simultaneously mapped to any three DMX512 channels
(providing RGB/CMY control).
• DMX loads cannot be used with daylighting. Accessory Controls: Ethernet and RS232 Interface
(QSE-CI-NWK-E)
• Allows for monitoring and control of the outputs and local
scenes of the GRAFIK Eye® QS.
Accessory Controls: QS Keyswitch Wallstations
(QSWS2-KS) • Recalls preset light levels for any two scenes including Off.
• Allows fine-tuning (raise/lower level) of a zone or group of
zones.
• Starts/Stops scene sequencings (Scenes 1-4 or Scenes
5-16)
• Enables/Disables Timeclock
• Enables/Disables occupancy sensors
• Enables/Disabled daylight sensors
• Allows toggle of Zone(s) to a preset level and off.
• Enables/Disables panic mode.
• Starts/Stops afterhours mode.
Other Accessory Controls and Devices
• Energi Savr NodeTM QS (ESN)
Occupancy Sensor(s)
• The GRAFIK Eye® QS works with occupancy sensors
through either:
- Scene Control: Up to four sensors activate userselectable occupancy and vacancy scenes.
- Zone Control: up to four sensors per zone activate userselected occupancy and vacancy zone levels.
• Occupancy sensors may include:
- Contact closure sensors wired to CCI input on back of
GRAFIK Eye® QS
- Wired sensors connected QS Sensor Module (QSM)
• If any sensor in a group detects occupancy, then the
GRAFIK Eye® QS will go to the designated occupancy
scene or zone level.
• If all sensors in a group detect vacancy, then the GRAFIK
Eye® QS will go to the designated vacancy scene or zone
level.
Page 5
100 V
Control Unit
Preset Dimming Controls
369430 Rev. A 6 04.25.11
Specifications
Daylight Sensor(s)
• The GRAFIK Eye® QS allows daylight sensors to control
one or more lighting zones to adjust electric light levels
based on measured daylight levels.
• Daylight sensors may include:
- Wired sensors connected to a QS sensor module (QSM)
• A daylight sensor can control one or more GRAFIK Eye®
QS zones:
- Each zone can be calibrated to target light levels
- A zone can be controlled by no more than one daylight
sensor
• Daylight control can be enabled or disabled on a sceneby-scene basis
- By default, daylight control is enabled in all scenes
Note: Daylight control through the GRAFIK Eye® QS only
affects lighting loads. Shade groups cannot be controlled
by daylight sensors. Daylighting does not affect DMX or
RGB/CMY DMX loads.
Contact Closure Input (CCI) with Power Supply Output
• Each GRAFIK Eye® QS has one contact closure input
(Terminal A).
- The attached device must provide a dry contact closure
or solid-state output.
- Input is miswire-protected up to 36 V .
• The contact closure is capable of accepting the following
types of inputs:
- Maintained (default): The GRAFIK Eye® QS control unit
will act on both a contact closure and a contact open/
release event.
- Momentary: The GRAFIK Eye® QS control unit will act on
only contact closure events.
• Each GRAFIK Eye® QS can supply 50 mA maximum at
24 V .
- Useful for powering occupancy sensors.
- An auxiliary power supply must be used if the device
requires more than 50 mA.
• The CCI is capable of operating in the following modes
- Occupancy: If an occupancy sensor is wired directly to
the GRAFIK Eye® QS.
- Emergency: This setting allows the GRAFIK Eye® QS to
work with a LUT-ELI. When an emergency situation is
detected, all lights will go to full on, and no operations
will be allowed until the emergency signal is cleared.
- Afterhours: Allows the CCI to start and end the
afterhours mode.
- Timeclock: Allows the CCI to enable and disable the
timeclock.
- Scene Lockout: Prevents the user from making any
changes to the control unit. The current scene will stay
on until the CCI enables normal operation.
- Save Never: Prevents any changes from being saved
while the CCI is being used.
- Disable CCI: The CCI will have no effect on the system
and will not appear on the list of available sensors.
Security Lockout Password
• A 4-digit password (using characters A to Z and 0 to
9) can be enabled/disabled to lock out access to the
Programming Menu.
• By default there is no password enabled on the GRAFIK
Eye® QS.
• If case the 4-digit password is forgotten, contact Lutron
Technical Support to regain access.
®
SPECIFICATION SUBMIT T A L
Job Name:
Job Number:
Model Numbers:
Page 6
100 V
Preset Dimming Controls
Control Unit
369430 Rev. A 7 04.25.11
GRAFIK Eye® QS
Custom Color Options and Model Numbers
You must order a Base Unit and a Faceplate Kit
See Standard Color Combinations page for faceplate, stripe, and button colors
Base Unit
Example:
QSGR
- _ PJA
QSGR-6PJA
6-zone base unit
and
QSGFP-2IV-EGN
Ivory faceplate kit with two
shade columns and general
engraving
Phase Control Triac
Prefix
Number
of Zones
3 = 3 zones
4 = 4 zones
6 = 6 zones
Faceplate Kit
(includes coordinating stripe and buttons)
-
QSGFP
Faceplate
Prefix
-
Number
of Shade
Columns
Omit = none
1 = 1 column
2 = 2 columns
3 = 3 columns
1 9
Color/
Finish
Top
Door
Color
Keypad
Engraving
Code
Omit = s ame as
unit
T = Translucent
2 10
3 11
4 12
5 13
6 14
7 15
1 9
8 16
Architectural Matte
Finishes
Standard
(ship in 48 hours)
White
Ivory
Beige
Gray
Brown Black
Almond
Light Almond
WH
IV
BE
GR
BR
BL
AL
LA
Architectural Metal
Finishes
Bright Brass
Bright Chrome
Bright Nickel
Satin Brass
Satin Chrome
Satin Nickel
Antique Brass
Antique Bronze
Anodized Aluminum
Finishes
Clear
Black
Brass
®
BB
BC
BN
SB
SC
SN
QB
QZ
CLA
BLA
BRA
Satin Color Matte
Finishes
Snow
Biscuit
Eggshell
Taupe
Midnight
Limestone
Stone
Desert Stone
Terracotta
Hot
Goldstone
Palladium
Plum
Turquoise
Bluestone
Sea Glass
Greenbrier
Sienna
Merlot
Mocha Stone
SPECIFICATION SUBMIT T A L
Job Name:
Job Number:
Model Numbers:
2 10
Keypad Engraving Codes
Faceplate Custom Color/Finish Codes
9-16
1-8
SW
BI
ES
TP
MN
LS
ST
DS
TC
HT
GS
PD
PL
TQ
BG
SG
GB
SI
MR
MS
3 11
4 12
5 13
Omit = U
nengraved
OK
Ships with engraving certificate that
customer can redeem at no charge
EGN = General Engraving
1
Open
2
Preset
3
Close
4
Off
Lighting
keypad
Shade
column
NST = N
on-Standard Text Engraving
Please visit the GRAFIK Eye® QS website
at www.lutron.com/grafikeyeqs
for custom engraving forms. Submit
completed form with order, and unit will
ship engraved as specified by customer.
Page 7
6 14
100 V
Preset Dimming Controls
Control Unit
369430 Rev. A 8 04.25.11
GRAFIK Eye® QS
Custom Options and Model Numbers
See previous page for Other Custom Model Numbers
See Standard Color Combinations page for faceplate, stripe, and button colors
Custom Button Kit
QSGB - 5B - WH Custom Button
Kit Prefix
Button
Configuration
3BRL = 3
-button with
raise/lower
(shade column)
5B
=2 105-button
3 11
4 12
1 9
(lighting keypad)
5 13
Keypad
Engraving
Code
Button
Color/
Finish
6 14
7 15
1 9
8 16
9-16
1-8
Button Kit Custom
Color/Finish Codes
Architectural Matte
Finishes
White
Ivory
Beige
Gray
Brown Black
Almond
Light Almond
WH
IV
BE
GR
BR
BL
AL
LA
Satin Color Matte
Finishes
Snow
Biscuit
Eggshell
Taupe
2 10
Keypad Engraving Codes
SW
BI
ES
TP
3 11
4 12
5 13
6 14
7 15
Omit = U
nengraved
OK
Ships with engraving certificate that
customer can redeem at no charge
EGN = General Engraving
1
Open
2
Preset
3
Close
4
Off
Lighting
keypad
Shade
column
NST = N
on-Standard Text Engraving
Please visit the GRAFIK Eye® QS website
at www.lutron.com/grafikeyeqs
for custom engraving forms. Submit
completed form with order, and unit will
ship engraved as specified by customer.
Custom Stripe Kit
QSGS - WH
Stripe Color/
Finish
Stripe
Kit
Prefix
Stripe Custom Color/Finish Codes
Same as Faceplate colors on previous page
®
SPECIFICATION SUBMIT T A L
Job Name:
Job Number:
Model Numbers:
Page 8
8 16
100 V
Preset Dimming Controls
Control Unit
369430 Rev. A 9 04.25.11
GRAFIK Eye® QS Standard Color Combinations
See previous pages for Custom Model Numbers
F (faceplate)
S (stripe)
Open
1
Preset
2
Close
3
4
Off
LUTRON
Suffix Faceplate (F)
Architectural Matte
WH
White
IV
Ivory
BE
Beige
GR
Gray
BR
Brown
BL
Black
AL
Almond
LA
Light Almond
Architectural Metal
BB
Bright Brass
BC
Bright Chrome
BN
Bright Nickel
SB
Satin Brass
SC
Satin Chrome
SN
Satin Nickel
QB
Antique Brass
QZ
Antique Bronze
Anodized
CLA
Clear
BLA
Black
BRA
Brass
®
Stripe (S)
Button (B)
Job Number:
F (faceplate)
Example:
If you order QSGR-4P-1WH, your GRAFIK
Eye® QS with 4 lighting zones and 1 shade
zone will come with a white faceplate (both
top and bottom), gray stripe, and white
buttons.
Suffix Faceplate (F)
Satin Matte
Gray
White
MN
Midnight
Beige
Ivory
TP
Taupe
Ivory
Beige
SW
Snow
Black
Gray
ES
Eggshell
Black
Brown
BI
Biscuit
Gray
Black
LS
Limestone
Light Almond Almond
ST
Stone
Almond
Light Almond DS
Desert Stone
TC
Terracotta
Black
Black
BG
Bluestone
Black
Black
HT
Hot
Black
Black
MR
Merlot
Black
Black
SI
Sienna
Black
Black
GB
Greenbrier
Black
Black
SG
Sea Glass
Black
Black
MS
Mocha Stone
Black
Black
GS
Goldstone
PD
Palladium
Black
Black
PL
Plum
Black
Black
TQ
Turquoise
Black
Black
SPECIFICATION SUBMIT T A L
Job Name:
B (buttons)
Faceplate is comprised of a top and bottom.
The bottom will always be the color indicated
under “faceplate.” The top may be the
same color or translucent. Use the chart for
faceplates that have the same color top and
bottom. If a translucent lid is chosen, the
stripe will automatically be the same color as
the bottom lid.
Model Numbers:
Stripe (S)
Button (B)
Gray
Gray
Gray
Beige
Eggshell
Gray
Gray
Taupe
Taupe
Gray
Taupe
Taupe
Brown
Gray
Gray
Taupe
Ivory
Gray
Taupe
Gray
Black
Taupe
Snow
Eggshell
Biscuit
Gray
Gray
Taupe
Taupe
Gray
Taupe
Taupe
Brown
Gray
Gray
Taupe
Ivory
Gray
Taupe
Gray
Page 9
100 V
Control Unit
Preset Dimming Controls
369430 Rev. A 10 04.25.11
Wiring Diagrams
Terminations
1 2 3 4 5 6 L N
Occupancy sensor/contact closure input and 24 V
power
1 2
A B C
1 2 3 4
Communication link
IR input
Load wiring
®
SPECIFICATION SUBMIT T A L
Job Name:
Job Number:
Model Numbers:
Page 10
100 V
Preset Dimming Controls
Control Unit
369430 Rev. A 11 04.25.11
Power Group Wiring Example
On the QS link, there are devices that supply power and devices that consume power. Each device has a specific
number of Power Draw Units (PDUs) it either supplies or consumes. A Power Group consists of one device that
supplies power and one or more devices that consume power; each Power Group may have only one power-supplying
device. Refer to the QS Link Power Draw Units specification submittal (Lutron PN 369405) for more information
concerning PDUs.
Within Power Groups on the QS link, connect all 4 terminals (1, 2, 3, and 4), shown by the letter A in the diagram.
Between devices on the QS link that supply power, connect only terminals 1, 3, and 4 (NOT terminal 2), shown by the
letter B on the diagram.
Wiring can be T-tapped or daisy-chained.
A
Power Group 1
LUTRON
GRAFIK Eye® QS
control unit
Supplies PDUs
A
LUTRON
B
Control Interfaces
Consume PDUs
(Do not connect
terminal 2: 24 V )
Wallstations
Consume PDUs
Power Group 2
A
Connect all 4
terminals within a
power group:
1: Common
2: 24 V
3 and 4: Data
B
LUTRON
Energi Savr NodeTM QS
Supplies PDUs
LUTRON
LUTRON
Wallstations
Consume PDUs
B
(Do not connect
terminal 2: 24 V
)
Connect only 3
terminals between
power groups:
1: Common
3 and 4: Data
Do not connect
Terminal 2: 24 V
Power Group 3
A
QS Power Supply
Supplies PDUs
LUTRON
Control Interfaces
Consume PDUs
Wallstations
Consume PDUs
B
(Do not connect
terminal 2: 24 V )
®
Quantum®
Supplies PDUs
SPECIFICATION SUBMIT T A L
Job Name:
Job Number:
QS Sensor Module with
wired Occupancy Sensor
Consumes PDUs
Model Numbers:
Page 11
100 V
Preset Dimming Controls
Control Unit
369430 Rev. A 12 04.25.11
Mounting
Mounting
screws (4)
Standard 4-gang
U.S. wallbox,
3` in (89 mm)
deep
Hinged
top lid
GRAFIK Eye®
QS control unit
Hinged
bottom lid
Line Voltage Wiring
Rear of
QS control unit
1 2 3 4 5 6 L N
To Load 1
Line voltage (hot/live)
is labeled L.
To Load 2
To Load 3
To Load 4
To Load 5
To Load 6
1 2 3 4 5 6 L N
Distribution Panel
100 V
50 / 60 Hz
• Pull power wiring from distribution panel and to light fixtures.
• Each line voltage terminal can accept one 12 AWG (2.5 mm2) wire.
• Consult Lutron for non-dim relay wiring and/or load side emergency transfer wiring.
®
SPECIFICATION SUBMIT T A L
Job Name:
Job Number:
Model Numbers:
Page 12
100 V
Preset Dimming Controls
Control Unit
369430 Rev. A 13 04.25.11
IEC PELV/NEC® Class 2 QS System Low-Voltage Wiring
• System communication uses low-voltage wiring.
• Wiring can be daisy-chained or T-tapped.
• Wiring must be run separately from line/mains voltage.
• IEC PELV/NEC® Class 2 wiring link requires:
- Two 18 AWG (1.0 mm2) conductors for control power.
- One twisted, shielded pair of 22 AWG (0.5 mm2) for data link.
- Available from Lutron, P/N GRX-CBL-346S; check compatibility in your area.
• Total length of control link must not exceed 2000 ft (610 m).
Daisy-Chain Wiring Example
GRAFIK Eye® QS
Control Unit
seeTouch® QS
wallstations
Sivoia® QS
Shade
LUTRON
LUTRON
LUTRON
LUTRON
LUTRON
LUTRON
LUTRON
Sivoia® QS
smart panel
LUTRON
LUTRON
LUTRON
LUTRON
LUTRON
LUTRON
LUTRON
T-Tap Wiring Example
GRAFIK Eye® QS
Control Unit
LUTRON
seeTouch® QS
wallstations
LUTRON
LUTRON
LUTRON
LUTRON
LUTRON
LUTRON
LUTRON
LUTRON
Sivoia® QS
smart panel
LUTRON
LUTRON
LUTRON
Sivoia® QS
Shade
LUTRON
LUTRON
®
SPECIFICATION SUBMIT T A L
Job Name:
Job Number:
Model Numbers:
Page 13
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement