1000W Grid Tie Inverter TEG-1000W-WV 22V-60V

1000W Grid Tie Inverter TEG-1000W-WV 22V-60V
1000W Grid Tie Inverter TEG-1000W-WV 22V-60V
System Function
directly connected to the solar panels (do not need to connect the battery)
Using precise MPPT function, APL functions, the inverter automatically adjust the solar panels of maximum output
power,simply connect the solar panel to the grid inverters. Do not need to connect the battery.
Operation Procedures
1, Connect the Solar Panel or Wind Turbine’s DC supply cables to the DC input terminal of the inverter, be sure that
the polarity is correct. Recommended DC input cable size for maximum output is 8AWG or cables that can handle
more than 30A. Optimal length would be less than 8m, longer cables will experience higher voltage drop.
2, Put the AC output voltage switch on the inverter to the correct position (115V or 230V) according to your location
home grid AC voltage.
3, Connect the supplied AC power cord to the inverter and plug it to a home wall socket.
4, The 3 green LED indicators will start to cycle from left to right when the grid and DC supply is detected. This
indicates the inverter is operating under normal condition. The rate of the cycling is according to how much power is
being output from the solar panels or the wind turbine. The more big output power is, the more fast the rate is. If
there is no AC grid detected, the red LED will be on, the inverter will not put out power, this is called “Island
Protection”.
System Function
Synchronous High-frequency Modulation In the process of the grid, usually adapt the same phase angle in parallel.
(ie, When the two-phase alternating current total is equal to 0.Use switch to combination the two AC fusion) and the
product is rectified AC half-frequency AC to 100Hz first, then the machine use the high frequency current in the
circuit and semi-100Hz frequency alternating current generated combination, to achieve high-frequency modulation.
Pure Sine Wave Output Use SPWM directly to make pure sine wave output.
Maximum Power Point Tracking (MPPT) Because the current intensity and the voltage changes at any time, if there
is no power point tracking, there will be a lot of problems. In the past time, usually adopt a solar controller, but this
product uses high-precision MPPT operation power, automatic and immediate adjust the solar panels output power
at the maximum output point, then achieve a stable output purposes.
Automatically Adapt To Different Load Power Factor Adapt to any of the power load.
Constant Current, Constant Power This product is constant current, constant output power, without any overload,
over-current phenomenon.
Automatically Shut Down When The Power Output Of a Fault When the city power system is in failure, the inverter
will automatically turn off the output. Current Limit Protection . Current limit
Specifications
Model
Normal AC Output Power
Maximum AC Output Power
Switch is at 230V Position
Switch is at 115V Position
AC Output Voltage Range
AC Output Frequency Range
Total Harmonic Distortion(THD)
Power Factor
DC Input Voltage Range ( Optional )
Peak Inverter Efficiency
Standby Power consumption
Output Current Waveform
MPPT Function
Over Current Protection
Over Temperature Protection
Reverse Polarity Protection
Anti-Island Protection
Stackable
Operating Temperature Range
N.W.
G.W
Dimension
TE-1000G-WV
900W
1000W
190V ~ 260V
90V ~ 130V
46Hz ~ 65Hz
<5%
0.99
22V ~ 60V
93%
<0.5W
Pure Sine-wave
Yes
Yes
Yes
Yes
Yes
Yes
-10 0C ~ 45 0c
5Kg
5.5Kg
405mm*275mm*123mm
่ั
ห้างหุน
้ สว่ นจาก ัด ท็อป อินเตอร์ เทค โซลูชน
ั เขตคลองสามวา กรุงเทพฯ 10510
778/170 หมูบ
่ า้ นประภาทร ัพย์ 4 ถ.เจริญพ ัฒนา แขวงบางชน
โทร : 081-8956728 081-8956728 ,082-7161442,082-7944159
Email : [email protected]
www.topintertech.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement