Product data sheet
Sheet No.: BQ1.601.00 - Rev: 2
Date:
January 2017
Q-Series
Contents
Bettis Q-Series Valve Actuator 2
General Overview........................................................................................................2
Bettis Q-Series Actuator Torque 4
Double Acting Actuators.. - Nm ...................................................................................4
Spring Return Actuators... - Nm...................................................................................5
Spring Return Actuators... - lbf.in.................................................................................6
Bettis Q-Series Valve Actuator Dimensions 7
Metric Actuators - ISO5211..........................................................................................7
Imperial Actuators - ISO5211.......................................................................................8
Metric Actuators - DIN3337.........................................................................................9
Bettis Q-Series Valve Actuator Options
10
Drive Inserts..............................................................................................................10
Position Indication - Center Plate............................................................................... 11
Control Modules 12
QC41, QC42 and QC43 .............................................................................................12
QC40 AS-Interface bus communication.....................................................................21
QC54 Foundation Fieldbus bus communication........................................................30
Miscellaneous Information
43
Parts and Materials Actuator and Modules................................................................43
Failure Modes............................................................................................................45
Double acting assembly codes..................................................................................46
Single acting (Spring Return) assembly codes...........................................................47
Corrosion Protection.................................................................................................48
How to Order
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
49
Product data sheet
Sheet No.: BQ1.601.01 - Rev: 1, page 1 of 2
Date:
January 2017
Q-Series
Bettis Q-Series "fully integrated" actuator and
control modules
General Overview
Description
The Bettis Q-Series package consists of an actuator with a
module for control and position feed back and forms an
integrated concept for “On/Off” valve automation.
Bettis Q-Series valve actuator with Control Module
3
6
1 Basic actuators
The basic actuator supplies the torque, required to open
and close valves and is available in various sizes (rated
47 to 1676Nm at 5.5barg or 413 to 14874 In.lb. at 80pisg).
Double acting and spring return executions are available.
The spring return execution can be equipped with multiple
spring sets to cover a pressure range from 2 to 8 barg (30 to
120 psig).
2 Control Modules
The Control Modules contain, next to the components
for feedback switches, also all the pneumatic control
components.
Its compact and robust construction incorporates basic
control and feedback functionality and is suitable for indoor
and outdoor use.
1.The enclosure of the control modules are rated IP66 /
NEMA 4X according IEC 60529 and are suitable for indoor
and outdoor use.
2. The QC41, QC42 and QC43 Explosion proof control
modules are suitable for use in potentially explosive
atmospheres and are available with FM, CSA, ATEX or
IECEx approvals
3. The QC40 with AS-Interface bus communication is a
available with Non-Sparking Ex nA or Non Incendive
approvals and is suitable for use in potentially explosive
atmospheres. For this QC40 ASI module cFMus, ATEX or
IECEx approvals are available.
4. The QC54 with Foundation Fieldbus bus communication
is a available with Non-Sparking Ex nA or Non Incendive
or Intrinsically Safe approvals and is suitable for use in
potentially explosive atmospheres. For this QC54 ASI
module cFMus, ATEX or IECEx approvals are available.
5. Both the weather proof and certified control modules
are available with the Fail-In-Last-Position control function
for double acting actuators and the non intrusive switch
point adjustment.
1
5
4
2
8
1 Basic Actuator
2 Control Module
3 Limit stop screws for
“Open” and “Closed”
position
4 G1/4” air connections
5 Optional: Built-in speed
control
6 Visual position indication
7 Optional: Manual Control
8 Electrical entries
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
7
Product data sheet
Sheet No.: BQ1.601.01 - Rev: 1, page 2 of 2
Date:
January 2017
Q-Series
Actuator specifications:
Construction
- Ingress protection rated IP65 / NEMA4X and suitable for
indoor and outdoor installation.
Finish
- Housing:
- Pistons:
- Pinion:
Anodized with a polyurethan powder coating
Chromate treatment.
Hard anodized
Lubrication
- Factory lubricated for the normal life of the actuator.
Temperature
- Depends on the Control Module used. See applicable data
sheets BQ1.604.xxx.
European Directives
- The basic actuator complies to PED 2014/68/EU, Machinery
Directive 2006/42/EC and to ATEX 2014/34/EU and is
II 2 GD c IIC TX
marked:
- This product is only intended for use in large-scale fixed
installations excluded from the scope of Directive 2011/65/
EU on the restriction of the use of certain hazardous
substances in electrical and electronic equipment (RoHS 2).
Pressure
- Double acting:
2 to 8 bar / 30 to 120 psi
- Spring return - with maximum spring set: 6 to 8 bar / 87 to 120 psi
- with reduced spring set: 3 to 8 bar / 43 to 120 psi
Operating media
- Dry air or inert gasses, filtered to 50 microns.
- Dew point 10K below operating temperature. For subzero
applications take appropriate measures to protect the
installation.
Torque
- 40 to 1600 Nm. (300 to 11000 lbf.in ) See sheets
BQ1.602.01, BQ1.602.02 or BQ1.602.03.
- Clockwise fail-to-close action, see sheet BQ1.606.04 for
optional fail-to-open action (assembly codes).
- See BQ1.606.03 for other double acting assembly codes.
- For more info on failure modes see BQ1.606.02
Cycle life
- 500.000 cycles minimum
Control Modules:
The following versions of Control modules are available.
Please check the indicated data sheet for more detailed
information.
- QC41 24VDC BQ1.604.10
- QC42 115VAC BQ1.604.10
- QC43 230VAC BQ1.604.10
- QC40 AS-Interface BQ1.604.11
- QC54 Foundation Fieldbus BQ1.604.12
Options
Speed control, Manual control, IECEx, ATEX, FM or CSA
approvals, glands, quick connectors, exhaust port filters and
silencers.
Functions:
Double or Single Acting (spring return)
Fail-in-Last position
Actuator range:
Suitable for Q40 to Q1600 (see note below).
Enclosure :
IP66 / NEMA4X
Pneumatic connections:
G1/4” or 1/4"NPT
“Breather” function:
Standard for single acting actuators
Options :
Speed control, exhaust port filters or silencers.
Rotation
- Factory set at 90°±0.5°. Adjustable range: -3° to +15° and
+75° to 93°
+15°
-3°
90°±0.5
+75°
Actuator data
Bore
Stroke
Double acting
Weight:
Spring return
+93°
Q-Series Valve Actuator:
Rotation and adjustable
range
mm.
inch
mm.
inch
kg.
lb.
kg.
lb.
sec.
Operating time
Air consumption per stroke
Central air chamber
at 1 atm (litres)
Endcap air chambers
Central air chamber
at 1 atm (cu. in.)
Endcap air chambers
Q40
70
2,76
18,8
0,74
1,8
4,0
2,4
5,3
0,7
Q65
80
3,15
22,0
0,87
2,4
5,3
3,6
7,9
1,1
Q100
91
3,58
25,1
0,99
3,1
6,8
4,6
10
1,2
Q150
103
4,06
31,4
1,24
4,5
9,8
6,9
15,1
1,8
Q200
110
4,33
37,7
1,48
5,8
13
9,1
20
2,3
Q350
145
5,71
37,7
1,48
10,4
23
17
37
3,6
Q600
175
6,89
44,0
1,73
19
43
28
61
4,5
0,16
0,22
10
13
0,33
0,36
20
22
0,35
0,49
21
30
0,84
0,78
51
48
0,8
1
49
61
1,8
1,9
110
116
2,9
3,1
177
189
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Q950 Q1600
200
230
7,87
9,06
50,3
62,8
1,98
2,47
26
43
58
94
39
66
85
145
5,4
6,9
4,7
4,9
287
299
7,3
8,0
445
488
Product data sheet
Sheet No.: BQ1.602.01 - Rev: 1
Date:
April 2015
Q-Series
Bettis Q-Series Actuator Torque
Double Acting Actuators
Actuator
type
QD
QD
QD
QD
QD
QD
QD
QD
QD
40
65
100
150
200
350
600
950
1600
Actuator
type
QD
QD
QD
QD
QD
QD
QD
QD
QD
40
65
100
150
200
350
600
950
1600
2
17
25
38
60
82
143
243
363
600
30
153
233
344
551
754
1310
2226
3323
5493
3
25
38
57
91
124
216
368
549
907
45
231
352
520
833
1140
1981
3366
5025
8307
3.5
29
45
66
106
146
253
430
642
1061
50
257
391
579
927
1269
2205
3747
5593
9245
- Nm
4
34
51
76
122
167
290
492
735
1214
Torque (Nm)
Supply Pressure (bar g)
4.5
5
5.5
38
42
47
58
64
71
86
95
105
137
153
168
188
209
230
326
363
400
554
617
679
828
921
1014
1368
1522
1676
6
51
77
115
183
251
436
741
1107
1829
6.5
55
84
124
199
272
473
804
1200
1983
7
59
90
134
214
293
510
866
1293
2137
8
68
104
153
245
335
583
991
1479
2444
60
309
471
696
1115
1526
2652
4507
6727
11121
Torque (lbf.in)
Supply pressure (psig)
65
70
75
335
361
387
511
550
590
755
814
873
1209
1303
1397
1655
1784
1913
2876
3100
3323
4887
5267
5647
7295
7862
8430
12059
12998
13936
80
413
630
931
1491
2041
3547
6028
8997
14874
90
465
709
1049
1680
2299
3994
6788
10132
16750
100
518
789
1166
1868
2556
4442
7548
11267
18626
120
622
948
1401
2244
3071
5337
9069
13537
22379
Double acting torque diagram
START
START
END
END
TORQUE
ROTATION
Note:
1.Emerson recommends that the valve manufacturer supply the maximum required torque values
(Including any adjustments or suggested safety factors for valve service conditions or application). Additionally, the valve
manufacturer must identify at which position(s) and direction(s) of rotation (Counter Clock Wise or Clock Wise) these
maximum requirements occur.
2.If in doubt, or you require any assistance with sizing actuators, do not hesitate to contact your nearest Emerson’s
Actuation Technologies representative.
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.602.02 - Rev: 0
Date:
May 2014
Q-Series
Bettis Q-Series Actuator Torque
Spring Return Actuators
Spring set
nr.
Actuator
Size
QS 40
2
3
4
5
6
QS65
2
3
4
5
6
QS 100
2
3
4
5
6
QS 150
2
3
4
5
6
QS 200
2
3
4
5
6
QS 350
2
3
4
5
6
QS 600
2
3
4
5
6
QS 950
2
3
4
5
6
QS 1600 2
3
4
5
6
3
C
17
12
26
18
39
29
63
46
85
61
144
101
249
179
375
272
617
445
-
D
11
4
17
4
27
10
41
14
57
19
96
30
166
54
248
82
416
144
-
3.5
C
D
22
16
17
8
12
1
32
23
25
11
49
37
39
20
28
3
79
58
62
30
107 79
84
41
60
4
183 135
140 68
97
2
315 232
245 120
174
8
474 347
371 181
268 14
780 579
608 307
436 35
-
4
C
D
26
21
21
13
17
5
39
30
32
18
24
6
60
47
49
30
39
13
95
74
79
47
62
19
130 101
106 64
83
26
221 174
179 107
136 41
381 298
311 186
240 74
572 446
469 279
366 113
943 742
771 470
599 198
-
- Nm
Air Torque (Nm)
Supply pressure (bar g)
4.5
5
C
D
C
D
31
25
35
30
26
17
31
22
21
10
26
14
17
2
21
7
46
37
53
44
39
25
45
32
31
13
38
20
23
1
30
8
70
57
80
67
59
40
70
51
49
24
59
34
38
7
49
17
38
0
112 90 128 107
95
63 111 79
78
36
94
52
78
24
152 124 174 146
129 86 151 109
105 49 127 71
82
11 104 33
260 213 299 251
217 146 256 185
175 80 214 118
132 13 171 52
447 364 513 430
377 252 443 318
306 140 372 206
236 28 302 94
671 544 769 643
568 378 666 476
465 211 563 310
362 45 460 143
1106 905 1269 1068
934 633 1097 796
762 361 925 523
590 88 753 251
-
5.5
C
D
40
34
35
27
30
19
26
11
21
4
60
51
52
39
45
27
37
15
30
3
90
78
80
61
69
44
59
27
48
11
144 123
128 96
111 68
94
41
197 168
173 131
150 93
126 56
103 18
338 290
295 224
252 157
210 91
167 24
579 496
509 384
438 272
368 160
298 48
868 741
765 575
662 408
559 242
455 75
1432 1231
1260 959
1088 686
916 414
744 142
6
C
D
44
39
40
31
35
23
30
16
25
8
67
58
59
46
52
34
44
22
36
10
100 88
90
71
79
54
69
38
59
21
161 139
144 112
127 85
110 57
94
30
219 191
196 153
172 116
149 78
125 41
377 329
334 263
291 196
248 130
206 63
645 562
575 450
504 338
434 226
364 114
966 840
863 673
760 507
657 340
554 174
1594 1394
1423 1121
1251 849
1079 577
907 305
7
C
D
53
48
49
40
44
32
39
25
34
17
81
72
73
60
65
48
58
35
50
23
121 108
110 91
100 75
89
58
79
41
193 172
177 145
160 117
143 90
126 62
264 236
240 198
217 160
193 123
170 85
454 407
412 340
369 274
326 207
283 141
777 694
707 582
636 470
566 358
496 246
1163 1037
1060 870
957 704
854 537
751 371
1920 1719
1748 1447
1576 1175
1405 903
1233 630
Spring
Torque
(Nm)
E
F
13
8
20
12
26
17
33
21
40
25
21
13
32
20
42
26
53
33
63
40
29
18
44
27
58
36
73
46
88
55
48
29
72
44
95
58
119 73
143 88
65
41
98
61
131 82
163 102
196 123
116 74
174 112
232 149
289 186
347 223
195 122
292 183
389 245
487 306
584 367
290 179
434 269
579 359
724 448
869 538
474 299
711 449
947 598
1184 748
1421 897
Spring return
torque diagrams
C=
Start
Air stroke
D=
End
Torque
Rotation Counter
Clockwise
E=
Start
Spring stroke
F=
End
Torque
Rotation Clockwise
Note:
1.Emerson recommends that the valve manufacturer supply the maximum required torque values (Including any adjustments
or suggested safety factors for valve service conditions or application).
Additionally, the valve manufacturer must identify at which position(s) and direction(s) of rotation (Counter Clock Wise or
Clock Wise) these maximum requirements occur.
2.If in doubt, or you require any assistance with sizing actuators, do not hesitate to contact your nearest Emerson’s
Actuation Technologies representative.
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.602.03 - Rev: 0
Date:
April 2015
Q-Series
Bettis Q-Series Actuator Torque
Spring Return Actuators
Spring set
nr.
Actuator
Size
QS 40
2
3
4
5
6
QS 65
2
3
4
5
6
QS 100
2
3
4
5
6
QS 150
2
3
4
5
6
QS 200
2
3
4
5
6
QS 350
2
3
4
5
6
QS 600
2
3
4
5
6
QS 950
2
3
4
5
6
QS 1600 2
3
4
5
6
40
C
133
196
303
211
485
656
1105
1920
2898
4765
-
D
82
117
192
44
297
406
684
1183
1777
2988
-
- lbf.in
Air Torque (lbf.in)
Supply pressure (psig)
60
80
90
C
D
C
D
C
D
243
193
354
303
409
358
201
125
312
236
367
291
159
58
270
169
325
224
227
101
283
156
241
89
364
285
533
454
617
538
297
178
466
347
550
431
230
71
398
240
482
324
331
133
415
217
348
110
552
441
801
690
926
814
460
293
709
541
833
666
367
144
616
393
740
518
523
245
648
369
430
96
555
221
884
696
1283 1094 1482 1294
735
453
1134
852
1333 1051
587
210
985
609
1185
808
837
366
1036
565
887
322
1201
952
1747 1497 2020 1770
994
619
1539 1165 1812 1438
786
287
1332
832
1604 1105
1124
500
1396
772
1189
440
2053 1632 3001 2580 3475 3054
1675 1043 2623 1991 3097 2465
1297
454 2245 1402 2719 1877
1866
814
2340 1288
1962
699
3531 2794 5142 4405 5947 5211
2909 1804 4520 3415 5325 4221
2287
814
3898 2425 4703 3230
3276 1434 4081 2240
3459 1250
5303 4182 7708 6587 8910 7789
4391 2709 6796 5114 7998 6316
3479 1236 5883 3641 7086 4844
4971 2168 6174 3371
5262 1898
8741 6964 12716 10939 14704 12927
7220 4554 11195 8530 13183 10517
5699 2144 9675 6120 11662 8108
8154 3711 10141 5698
8621 3289
100
C
D
464
414
422
346
380
279
338
212
296
144
701
622
634
515
567
408
499
301
432
194
1050
939
957
790
865
642
772
494
679
345
1681 1493
1533 1250
1384 1007
1235
764
1087
522
2293 2043
2085 1710
1877 1378
1669 1045
1462
713
3949 3528
3571 2939
3193 2351
2814 1762
2436 1173
6753 6016
6131 5026
5509 4036
4887 3046
4265 2055
10113 8992
9201 7519
8288 6046
7376 4573
6464 3100
16692 14915
15171 12505
13650 10096
12129 7686
10608 5277
120
C
D
575
524
533
457
491
390
448
322
406
255
870
790
802
683
735
576
668
470
601
363
1299 1188
1206 1039
1114
891
1021
743
928
594
2080 1892
1931 1649
1783 1406
1634 1163
1485
920
2838 2589
2631 2256
2423 1923
2215 1591
2007 1258
4897 4476
4519 3887
4141 3299
3762 2710
3384 2121
8364 7628
7742 6637
7120 5647
6498 4657
5876 3666
12518 11396
11606 9924
10693 8451
9781 6978
8869 5505
20668 18890
19147 16481
17626 14071
16105 11662
14584 9252
Spring
Torque
(lbf.in)
E
F
117
73
176
110
234
146
293
183
351
220
186
117
279
176
372
234
465
292
558
351
258
161
387
242
516
323
646
403
775
484
423
259
634
388
845
517
1056
647
1268
776
579
362
868
542
1158
723
1447
904
1736 1085
1025
658
1537
987
2049 1317
2561 1646
3074 1975
1723 1082
2585 1624
3446 2165
4308 2706
5169 3247
2563 1587
3844 2381
5125 3175
6407 3968
7688 4762
4193 2646
6289 3970
8385 5293
10481 6616
12578 7939
Spring return
torque diagrams
C=
Start
Air stroke
D=
End
Torque
Rotation Counter
Clockwise
E=
Start
Spring stroke
F=
End
Torque
Rotation Clockwise
Note:
1.Emerson recommends that the valve manufacturer supply the maximum required torque values (Including any adjustments
or suggested safety factors for valve service conditions or application).
Additionally, the valve manufacturer must identify at which position(s) and direction(s) of rotation (Counter Clock Wise or
Clock Wise) these maximum requirements occur.
2.If in doubt, or you require any assistance with sizing actuators, do not hesitate to contact your nearest Emerson’s
Actuation Technologies representative.
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.603.08 - Rev: 0
Date:
May 2014
Q-Series
Bettis Q-Series Valve Actuator Dimensions
Metric Actuators - ISO5211
T
M5x8
4
D
G1/4"
30
C'
C
H
144
A (QD)
I
B (QS)
limit stops on Q40 & Q65
Pinion drive
details
Note:
1. Dimensions are metric (mm).
2. The limit stop screws on the Q40 and Q65 are on the opposite side to those
on the larger actuators.
3. Top flange according VDI/VDE 3845 (NAMUR)
P2
P1
N±0.5
M1 M2
K
W
V1
V
Flange for
W1 Q40 - Q950
O
P +0.5
-0
S
280
234.6
97.2
M16
x25
R
Flange for
Q1600
132
*) Four holes of the F25
ISO Drilling pattern
Dim
Bettis Q-Series actuator models
Q40
Q65
Q100
Q150
Q200
Q350
Q600
Q950
Q1600
in mm.
A QD
180
199
221
254
283
305
387
424
516
B QS
204
249
267
310
346
387
416
460
568
C
104
117
141
150
161
191
245
276
337
C’
137
150
175
184
194
225
289
319
380
D
20
20
20
20
20
20
30
30
30
E
56
56
56
65
66
66
84
88
95
F
16
18
18
22
30
30
35
35
45
G
9,5
9
11
10
9
10
19,5
19
28,5
H
90
102
115
129
135
177
209
234
268
I
212
218
225
232
235
256
272
284
301
J
40
40
34
46
45
46
53
40
70
K
33
33
38
55
55
55
68
75
95
M1
34.5
34.5
34.5
50
50
50
52
64
82
M2
27
37
37
N
1
1
1.5
1.0
1.5
1.5
1.5
1.5
1.5
O max.
14.11
14.11
19.13
19.13
22.13
27.13
27.13
36.16
46.16
O min.
14.00
14.00
19.00
19.00
22.00
27.00
27.00
36.00
46.00
P
18.1
18.1
25.2
25.2
28.2
36.2
36.2
48.2
60.2
P1
18.1
18.1
23.1
28.5
32.1
32.1
36.5
48.5
60.5
P2
25.2
36.2
36.2
R
65
70
70
90
90
114
124
130
154
S
65
70
70
90
90
114
124
142
280
T
80
80
80
80
80
80
130
130
130
PCD
F05/F07 F05/F07 F05/F07 F07/F10 F07/F10 F07/F10 F10/F12 F10/F14 F16/F25*
V
50
50
50
70
70
70
102
102
165
V1
70
70
70
102
102
102
125
140
W
M6x10 M6x10 M6x10 M8x13 M8x13 M8x13 M10x16 M10x16 M20x30
W1
M8x13 M8x13 M8x13 M10x16 M10x16 M10x16 M12x20 M16x25
-
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.603.09 - Rev: 0
Date:
April 2015
Q-Series
Bettis Q-Series Valve Actuator Dimensions
Imperial Actuators - ISO5211
T
10-24x .31
0.16
D
1/4” NPT
1.18
C'
C
H
5.65”
A (QD)
I
B (QS)
limit stops on Q40 & Q65
Note:
1. Dimensions are in inches.
2. The limit stop screws on the Q40 and Q65 are on the opposite side to those
on the larger actuators.
3. Top flange according VDI/VDE 3845 (NAMUR)
Pinion drive
details
P2
P1
N±0.02
M1 M2
K
W
V1
V
Flange for
W1 Q40 - Q950
O
P +0.02
-0
S
11.02
9.23
3.83
5/8"11x.98
R
Flange for
Q1600
5.20
*) Four holes of the F25
ISO Drilling pattern
Bettis Q-Series actuator models
Dim in
inches
Q40
Q65
Q100
Q150
Q200
Q350
Q600
Q950
Q1600
A QD
7.09
7.83
8.70
10.00
11.14
12.01
15.24
16.69
20.31
B QS
8.03
9.80
10.51
12.20
13.62
15.24
16.38
18.09
22.34
C
4.09
4.59
5.55
5.91
6.34
7.52
9.65
10.87
13.27
C’
5.39
5.92
6.89
7.24
7.64
8.86
11.38
12.56
14.96
D
0.79
0.79
0.79
0.79
0.79
0.79
1.18
1.18
1.18
E
2.20
2.20
2.20
2.56
2.60
2.60
3.31
3.46
3.74
F
0.63
0.71
0.71
0.87
1.18
1.18
1.38
1.38
1.77
G
0.37
0.35
0.43
0.39
0.35
0.39
0.77
0.75
1.12
H
3.54
4.02
4.53
5.08
5.31
6.97
8.23
9.21
10.55
I
8.65
8.9
9.16
9.45
9.57
10.43
11.08
11.59
12.29
J
1.56
1.56
1.32
1.81
1.78
1.81
2.08
1.58
2.75
K
1.30
1.30
1.50
2.17
2.17
2.17
2.68
2.95
3.74
M1
1.36
1.36
1.36
1.97
1.97
1.97
2.05
2.52
3.23
M2
1.06
1.46
1.46
N
0.04
0.04
0.06
0.04
0.06
0.06
0.06
0.06
0.06
O max. 0.556
0.556
0.753
0.753
0.871
1.068
1.068
1.424
1.817
O min.
0.551
0.551
0.748
0.748
0.866
1.063
1.063
1.417
1.811
P
0.71
0.71
0.99
0.99
1.11
1.43
1.43
1.90
2.37
P1
0.71
0.71
0.91
1.12
1.26
1.26
1.44
1.91
2.38
P2
0.99
1.43
1.43
R
2.56
2.76
2.76
3.54
3.54
4.49
4.88
5.12
6.06
S
2.56
2.76
2.76
3.54
3.54
4.49
4.88
5.59
11.02
T
3.15
3.15
3.15
3.15
3.15
3.15
5.12
5.12
5.12
PCD
F05/F07 F05/F07 F05/F07 F07/F10 F07/F10 F07/F10 F10/F12 F10/F14 F16/F25*
V
1.969
1.969
1.969
2.756
2.756
2.756
4.016
4.016
6.496
V1
2.756
2.756
2.756
4.016
4.016
4.016
4.921
5.512
1/4”1/4”1/4”5/16”5/16”5/16”3/8”3/8”3/4”W
20x.39 20x.39 20x.39 18x.39 18x.39 18x.39 16x.63 16x.63
10x1.14
5/16”5/16”5/16”3/8”3/8”3/8”1/2”5/8”W1
18x.39 18x.39 18x.39 16x.63 16x.63 16x.63 13x.79 11x.98
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.603.10 - Rev: 0
Date:
May 2014
Q-Series
Bettis Q-Series Valve Actuator Dimensions
Metric Actuators - DIN3337
T
M5x8
4
D
G1/4"
30
C'
C
H
144
I
A (QD)
B (QS)
limit stops on Q40 & Q65
P2
P1
Note:
1. Dimensions are metric (mm).
2. The limit stop screws on the Q40 and Q65 are on the opposite side to those
on the larger actuators.
Pinion drive details 3. Top flange according VDI/VDE 3845 (NAMUR)
and center plate
Dim
Bettis Q-Series actuator models
Q40
Q65
Q100
Q150
Q200
Q350
Q600
Q950
Q1600
in mm.
dimensions
N
±0.5
M1 M2
Max. 5
øK
øK1
V
W
O
P
+0.5
-0
Flange for
Q40 - Q950
R
S
280
234.6
97.2
M16
x25
Flange for
Q1600
132
*) Four holes of the F25
Drilling pattern
A QD
B QS
C
C’
D
E
F
G
H
I
J
K
K1
M1
M2
N
O max.
O min.
P
P1
P2
Q
R
S
T
PCD
V
W
180
204
104
137
20
56
16
9,5
86
212
40
33
32
34,5
1
14,11
14,00
18,1
18,1
35
65
65
80
F05
50
M6x10
199
249
116,5
150,4
20
56
18
14
102
218
40
33
32
34,5
1
14,11
14,00
18,1
18,1
70
70
80
50
F05
50
M6x10
K1’
Q’
PCD
V’
W’
40
55
F07
70
M8x13
40
35
F07
70
M8x13
221
267
141
175
20
56
18
11
108
225
34
38
40
34,5
27
1,5
17,13
17,00
22,2
23,1
25,2
55
70
70
80
F07
70
M8x13
254
283
305
387
424
310
360
387
477
517
150
161
191
245
276
184
194
225
289
319
20
20
20
30
30
65
66
66
84
88
22
30
30
35
35
10
9
10
19,5
19
129
128
173
207
231
232
235
256
272
284
46
45
46
53
40
55
55
55
68
75
50
54
54
68
75
50
50
50
52
64
37
37
1
1,5
1,5
1,5
1,5
17,13
22,13
22,13
27,13
36,16
17,00
22,00
22,00
27,00
36,00
22,2
28,2
28,2
36,2
48,2
28,5
32,1
32,1
36,5
48,5
36,2
36,2
55
70
70
85
100
90
90
114
124
130
90
90
114
124
142
80
80
80
130
130
F07
F10
F10
F12
F14
70
102
102
125
140
M8x13 M10x16 M10x16 M12x20 M16x25
Optional dimensions
32
54
50
50
35
70
55
55
F05
F10
F07
F07
F10
F10
50
102
70
70
102
102
M6x10 M10x16 M8x13 M8x13 M10x16 M10x16
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
516
637
337
380
30
95
45
28,5
265
301
70
95
95
82
1,5
46,16
46,00
60,2
60,5
130
154
280
130
F16
165
M20x30
F25*
-
Product data sheet
Sheet No.: BQ1.603.03 - Rev: 0
Date:
May 2014
Q-Series
Bettis Q-Series Valve Actuator Options
Drive Inserts
Description
All actuators are fitted with drive inserts. This enables
actuators to be directly mounted onto suitable valves and
eliminates the need for a bracket and coupling type mounting
kit. The use of direct mounts significantly cuts the cost of the
valve/actuator assembly.
Standard actuators are fitted with square drive inserts in
accordance with ISO 5211 (or DIN 3337), but a wide variety
of other inserts are also available. Special inserts may have
oversize or undersize squares, double-D and shaft key way
forms.
Drive inserts can be supplied on factory built actuators or as
loose items and are easily replaceable at distributor or end
user level.
Where direct mounts are not possible, for instance on valves
with exposed gland packing, the use of inserts often simplifies
the design of the mounting kit.
Material :
Finish:
Optional available
insert shapes
Standard available
insert shapes
D
Max.
sq
Max.
M1
Aluminum alloy
Anodized
Insert mounting
Insert mounting
acc. ISO 5211
acc. DIN 3337
Ø P2
Ø P2
Ø P1
Ø P1
M2
D
Max.
Q40
mm. inch
ISO5211
DIN3337
M1
M2
P1
P2
Sq max.
D max.
Q65
mm. inch
14
14
0.551
0.551
14
14
0.551
0.551
10
12
-
0.394
0.472
-
10
12
-
0.394
0.472
-
34.5 1.36
18.1 0.71
16 0.630
21 0.827
34.5 1.36
21.2 0.83
16 0.630
21 0.827
M1
Center
plate
Inserts with inner-square-dimensions per actuator type
Q100
Q150
Q200
Q350
Q600
mm. inch mm. inch mm. inch mm. inch mm. inch
Standard inserts dimensions
19 0.748 19 0.748 22 0.866 27 1.063 27 1.063
17 0.669 17 0.669 22 0.866 22 0.866 27 1.063
Optional insert dimensions
12 0.472 14 0.551 14 0.551 14 0.551 14 0.551
14 0.551 16 0.630 16 0.630 16 0.630 16 0.630
16 0.630 22 0.866 17 0.669 17 0.669 17 0.669
24 0.945 19 0.748 19 0.748 19 0.748
27 1.063 24 0.945 24 0.945 24 0.945
Maximum insert dimensions
34.5 1.36
50
1.97
50
1.97
50
1.97
50
1.97
27
1.06 37.0 1.46 37.0 1.46 37.0 1.46
23.5 0.93 28.5 1.12 32.2 1.27 32.2 1.27 36.8 1.45
25.2 0.99 36.2 1.43 36.3 1.43 36.3 1.43
19 0.748 27.0 1.063 27.0 1.063 27.0 1.063 27.0 1.063
23.6 0.929 33.6 1.323 33.6 1.323 33.6 1.323 33.6 1.323
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
M2
Q950
mm. inch
Q1600
mm. inch
36
36
1.417
1.417
46
46
1.811
1.811
22
-
0.866
-
-
-
65
48.3
36.0
45.0
2.56
1.90
1.417
1.772
81
3.19
60.5 2.38
46.0 1.811
60.0 2.362
Product data sheet
Sheet No.: BQ1.606.05 - Rev: 0
Date:
May 2014
Q-Series
Bettis Q-Series Valve Actuator Options
Position Indication - Center Plate
Visual position indicator
“In line”
“Cross line”
Bettis Q-Series valve actuators can be equipped with a large
visual position indicator which allows clear indication of the
valves position at almost any position.
The Bettis Q-Series indicator is designed for position indication
of actuators mounted “in line” with the pipe line and
mounted “cross line” with the pipe line. To do this the inner
part can be removed, turned 90° and pushed back in place.
When supplied, the position indicator will be mounted
“in line” as standard. See data sheet BQ1.606.04 for other
indicator mounting options.
Specifications:
Material disk
Material arrow
:
:
Nylon PA6, Black
Nylon PA6, White
Center plate for DIN3337 applications
Bettis Q-Series actuators can be equipped with a centre plate
which takes care that actuator and valve (or valve mounting
kit) are aligned when mounted. For most of the actuator sizes
two center plates are available.
Specifications:
Material plate
:
Nylon PA6, Black
Center plate
Bettis Q-Series actuator models
Q40
Q65
Std
F05
F05
Q100 Q200 Q350 Q600 Q950 Q1600
F07
F10
F10
F12
F14
F16
Option
F07
F07
F05
F07
F07
-/-
-/-
-/-
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 6, Page 1 of 9
Date:
March 2017
Q-Series
Integrated Control modules
QC41, QC42 and QC43
Features:
-
Basic actuator functions for:
- Spring return applications, or
- Double acting applications or,
- Double acting Fail in Last Position applications.
-
Suitable for all Bettis Q-Series actuator sizes.
-
Available as "Weather Proof" for indoors or outdoors use
and "Explosion Proof" for areas with a potential explosion
hazard.
- The robust aluminum alloy enclosure (IP66 / NEMA4X
rated), protects the IPT system, pneumatic components,
the feedback switches and terminals and makes it
suitable for indoor and outdoor use.
- The Explosion Proof version is available with ATEX /
IECEx Ex d approval for use in Zone 1, 2, 21 and 22 and/
or FM / CSA Explosion proof approval for use in Class I,
Division 1.
-
Various feedback switch options available.
-
Non-Intrusive switch point adjustment of the feedback
switches. Allows to adjust switch points without opening
the Control Module.
-
Lockable Control Module cover.
-
All the control and feedback connections can be wired
through one single entry to the Control Module.
-
One larger entry (3/4"NPT) is available for larger multicore cables on imperial units.
APPROVED
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 6, Page 2 of 9
Date:
March 2017
Q-Series
Description:
Electrical safety requirements:
These Bettis Q-Series conventionally wired control modules
are the next step for the integrated concept of valve
automation.
Next to the components for feedback switches, also all
the pneumatic control components are located inside one
module housing.
Its compact and robust construction incorporates basic
control and feedback functionality and is suitable for indoor
and outdoor use.
These modules are available with ATEX and IECEx
certification for use in Zone 1, 2, 21 and 22, and additionally
FM and CSA certified for use in Class I, Division 1.
Use
Altitude
: In- and outdoor.
: Operating full power available up to 2000 meter (6000 feet).
Maximum relative
: 80% for temperatures up to 31°C
humidity (87.8°F) decreasing linearly to 50% relative humidity at 40°C (104°F).
Mains supply
: Up to ±10% of nominal voltage
fluctuation
Over voltage category : II
Pollution degree
: 2
(3 when the cover remains closed)
Construction:
The Control Module is mounted at the side of the basic
actuator housing. Inside, wiring terminals are available for
connecting control and feedback signals. Two cable entries
are available.
The pilot valves inside the control module are used to send
the actuator to its open or closed position. One pneumatic
connection is available to feed the control module.
Terminal
Control Module
compartment
Type Label
Option: 1 or 2
speed control
throttles
Lockable
Module cover
General specifications:
Material housing:
Operating media:
Aluminium alloy
Air or inert gasses, filtered at 50µm
(for QC54 5µm)
Pneumatic entry:
Metric units: G1/4"
Imperial units:1/4”NPT
Electrical connections: Pilot valve(s): 6 pole terminal strip.
Switches:
6 pole terminal strip.
Cable entries:
Metric units: 2x M20x1.5
Imperial units:1/2” and 3/4"NPT
Enclosure:
Rated IP66 - NEMA4X
Switch points:
Factory set at 15° before each end
of travel (open and closed position).
- Adjustable range:
Between -3° to 15° and +75° to +93°
of the end position.
Finish:
Chromated, polyurethane based
coating.
Temperature range:
Depends on the switches inside
the module and or Hazardous Area
approvals (See section "Position
feedback"
Dimensions:Metric:
See data sheet BQ1.603.08
Imperial/UNC:
See data sheet BQ1.603.09
DIN 3337:
See data sheet BQ.1.603.10
Pneumatic connections:
1/4”BSP or 1/4”NPT
Option: Additional Local
Manual Control for “Fail in
Electrical entries:
Last Position”
Option: Local Manual Control
3/4”NPT
or M20
1/2”NPT
or M20
Non-Intrusive switch
Switch
Pilot valve
terminals
terminals
Control module overview
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
point adjustment
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 6, Page 3 of 9
Date:
March 2017
Q-Series
Pneumatic control
Pneumatic control variations
The Control Module contains all the necessary pneumatic
components to control the actuator and control the
incoming and outgoing airflow. Pneumatically the modules
are available for three applications:
1 Spring return or
2 Double acting or
3 Double Acting - "Fail-in-Last-Position".
To achieve these functions, each Control Module can
be fitted with one or two pilot valves depending on the
required functionality:
Pilot valve 1
Cable range:
0.33 - 2.5mm2 or
22 - 12AWG
One default pilot valve and wiring connections
1 One pilot valve is default and suitable for normal
operation of double acting or spring return actuators
2 Two pilot valves are required to achieve a "Fail-in-LastPosition" functionality on double acting actuators.
Pilot valve 1
Table 1: Pilot valve specifications
Module
Voltages
Power
QC41
24VDC (±10%)
1W
Frequency
NA
QC42
115 VAC (±10%)
3VA
50/60Hz
QC43
230 VAC (±10%)
3VA
50/60Hz
Pilot valve 2
Cable range:
0.33 - 2.5mm2 or
22 - 12AWG
FILP = Fail in Last Position
Wiring diagram shown, is applicable for actuators with assembly code “CW”.
For actuators with assembly code “CC” (reverse acting) the “Open” and
“Closed” pilot valve connections are also reversed.
Pneumatic cartridge
Pilot valve cartridge
Two pilot valves and wiring connections for Fail in Last Position
Pilot valve
terminals
Pilot valve and pneumatic cartridge
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 6, Page 4 of 9
Date:
March 2017
Pneumatic components
The pneumatic components inside the module consist
out of one or two pilot valves and a 3/2 spool valve or 5/2
bistable spool valve. The spool valves are pneumatically
operated by the pilot valves.
To assure trouble-free operation, the spool valves are
equipped with big ports. This enables a large air flow and
makes it less sensitive for contamination of the internals.
The large air flow also fast cycle times and enables it to be
utilized for the entire Bettis Q-Series actuator range.
Internal corrosion protection:
The spring return models have standard a built in “Breather”
function. During the spring stroke, the exhaust air from the
center chamber (A-Port) is first fed to the spring chamber
(B-port) preventing air from outside from being sucked into
the spring chamber. This reduces the possibility of internal
corrosion and maximizes the actuators’ working life.
Q-Series
Fail safe
(spring return)
A-port
B-port
Option: Throttle 1
3/2 Spool valve
Option: LMC
Ps
Ra
Pilot valve 1
Double acting
Pneumatic options
Speed Control
The Bettis Q-Series can be supplied with a Speed Control
option. One throttle is required for Spring Return actuators
and up to two for Double Acting actuators.
The speed control throttle controls the air flow in and
out of an air chamber and as such limits the speed of the
“Opening” and “Closing” stroke simultaneously.
Silencers and vents
A-port
B-port
Option:
Throttle 1
Option:
Throttle 2
5/2 Spool valve
Option: LMC
Rb
Ps
Ra
The exhaust ports Ra and Rb on the module are shipped
from the factory with transport protection.
The module can be equipped with either silencers or vents.
Pilot valve 1
Manual Control
For commissioning, emergency or maintenance purposes,
the Bettis Q-Series can be supplied with Manual Control
options. These options can operate the actuator when there
is air pressure available, but no control signal or power
supply.
- For normal operation the module should be fitted with
one Manual Control.
- For Double Acting with a Fail-in-Last-Position function,
two Manual Control can be fitted.
Double Acting
Fail in Last
Position
A-port
Option:
Throttle 1
Option:
Throttle 2
5/2 Spool valve
Maximum Flow rates of Q-Series modules
The maximum flow rates depends mainly on the flow rates
of the Bettis Q-Series modules. You can use Kv 0.28 (m3/h)
or Cv value of 0.33 (US gall/min 1Psi) for approximate
operating speed calculations.
B-port
Option: LMC 1
Option: LMC 2
Ps
Rb
Ra
Pilot valve 1
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Pilot valve 2
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 6, Page 5 of 9
March 2017
Date:
Q-Series
Position feedback
Non-Intrusive switch point adjustment
The position feedback is achieved by switch cartridges in the
module. These cartridges contain switching elements which
sense the open or closed position and are pre wired to the
terminal strip. These easily exchangeable switch cartridges
are available with various mechanical or proximity switching
elements.
If required the switches can be adjusted without opening
the module. This, so called, Non-Intrusive switch adjustment
is located at the front of the module behind a locable (1)
shield (2). Two adjustment screws are available for adjusting
the Closed (3) and Open (4) position indication.
N WHEN E
NING N
PE
O WAR
!-
G
ER
IZED
DO NO
T
Switch cartridges
Terminal strip position
feedback switches
3
4
1
2
Switch cartridge
Switch cartridges
"Closed"
Switch point adjustment
"Open"
Switch point adjustment
Non-Intrusive switch point adjustment
Important:
- The above "Closed" and "Open" marked adjustment
screws will adjust the valve's "Closed" or "Open" switch
point, if the valve closes after a Clock Wise (CW) rotation.
- If the valve closes after a Counter Clock Wise (CCW)
rotation, the "Closed" marked adjustment screw will adjust
the "Open" switch point. Similar, the "Open" marked
adjustment screw will adjust the "Closed" switch point.
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 6, Page 6 of 9
Date:
March 2017
Q-Series
Mechanical switches
2-Wire Proximity switches
Table 2: Mechanical switches
Table 4: 2-wire NAMUR proximity switches
Specification
Description
Specification
Description
Option code
M
Option code
N
Option code
G (gold contacts)
Type
2-wire inductive, normally closed
Type
Mechanical
Voltage
8 VDC nominal
Voltage
M: 277 VAC or 250VDC (maximum)
Output
Unswitched , > 3 mA
Temperature range
Switched , < 1 mA
-25°C to +65°C / -13°F to +149°F
For use in hazardous areas, see table 7
DIN EN 60947-5-6 (NAMUR)
G: 125 VAC or 30VDC (maximum)
Contacts
Temperature range
NO and NC
-25°C to +65°C / -13°F to +149°F
For use in hazardous areas, see table 7
Table 3: Maximum currents
Switch voltage
M type switch
G type switch
125 VAC
10 A (3 A1)
0.1 A 2
250 VAC
10 A (3 A1)
-
30 VDC
0.5 A
0.1 A 2
125 VDC
0.5 A
-
250 VDC
0.25 A
-
Note:
1. The mechanical (M-type) switches are rated for 3 A with
inductive load.
2 The mechanical (G-type) switches have gold contacts.
For applications where the benefits of gold contacts are
required, the maximum current is 1 A.
Compliant to
Table 5: 2-Wire 230V proximity switches
Specification
Description
Option code
H
20...250VAC / 10...300VDC
(50...60 Hz AC)
Maximum
100 mA
Voltage
Current
Peak
Leakage
0,9A (20ms / 0,5Hz),
< 1.7 mA
-25°C to +65°C / -13°F to +149°F
For use in hazardous areas, see table 7
Temperature range
Wiring diagram:
Wiring diagram:
- M = Mechanical
- 2-Wire NAMUR proximity switches
- 2-Wire 115V proximity switches
- G = Mechanical, gold contacts
1 L- 2
Open
Close
Cable range : 0.33 - 2.5mm2 or 22 - 12AWG
L+ 3
4 L- 5
2
2
1
1
L+ 6
Close
Open
Cable range : 0.33 - 2.5mm or 22 - 12AWG
2
Wiring diagram is shown in the actuators mid-stroke position.
Wiring diagram for mechanical switches
Wiring diagram for 2-Wire proximity switches
Important:
- The above "Closed" and "Open" marked adjustment terminals will indicate the valve's "Closed" or "Open" switch point, if
the valve closes after a Clock Wise (CW) rotation.
- If the valve closes after a Counter Clock Wise (CCW) rotation, the "Closed" marked adjustment terminals will indicate
the "Open" switch point. Similar, the "Open" marked adjustment terminals will indicate the "Closed" switch point.
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 6, Page 7 of 9
March 2017
Date:
Q-Series
3-Wire Proximity switches
Table 4: 3-wire proximity switches
Specification
Description
Option code
O, V3 PNP
Option code
C, V3 NPN
Function
Make
Voltage
10 - 30V
Current
100 mA maximum
Off-state current
0 ... 0.5 mA typical
-25°C to +65°C / -13°F to +149°F
For use in hazardous areas, see table 7
Temperature range
Wiring diagram:
3-Wire proximity "O" type switches PNP
L-
2
1
L+
3
L-
5
4
3
4
1
L+
6
L+
6
3
4
1
PNP
Open
Close
Wiring diagram:
3-Wire proximity "C" type switches NPN
L-
2
1
L+
3
3
4
1
L-
5
4
3
4
1
NPN
Open
Close
Cable range : 0.33 - 2.5mm2 or 22 - 12AWG
Wiring diagram for 3-Wire proximity switches
Important:
- The above "Closed" and "Open" marked adjustment terminals will indicate the valve's "Closed" or "Open" switch point, if
the valve closes after a Clock Wise (CW) rotation.
- If the valve closes after a Counter Clock Wise (CCW) rotation, the "Closed" marked adjustment terminals will indicate
the "Open" switch point. Similar, the "Open" marked adjustment terminals will indicate the "Closed" switch point.
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 6, Page 8 of 9
Date:
March 2017
Q-Series
Control Module Options
QC41, QC42 and QC43
Local Manual Control
Speed Control
Description
Description
For commissioning, emergency or maintenance purposes,
the Bettis Q-Series can be supplied with one or two Manual
Control options. These can operate the pilot valve(s) inside
the module and as such operate the actuator, when there
is air pressure available, but no control signal or power
supply.
The Bettis Q-Series can be supplied with a Speed Control
option. One throttle is required for Spring Return actuators
and up to two for Double Acting actuators.
The speed control throttle controls the air flow in and
out of an air chamber and as such limits the speed of
the “Opening” and “Closing” stroke simultaneously. This
throttle consists of :
1 Nut cover
2 Main throttle with set screw.
Notes:
- One Local Manual Control is required for normal
operation of Double acting or Spring return actuators.
- For Double acting actuator with a Fail-in-last position
function, a second Local Manual Control can be
mounted.
- These options can be ordered together with the Control
Module or as a kit to be mounted later.
- For option ordering codes, see page 11 of 11
Notes:
- For Spring Return actuators with one speed control
throttle, it is not possible to set both the stroke cycle
times to an equal time.
- Four Double Acting actuators it is possible to mount two
speed control throttles.
- The actual stroke cycle times depend on the actual load
on the actuator during the different strokes.
Spring Return:
Top entry only.
Double Acting:
Location for 2nd
Bottom and/or top entries.
Local Manual Control
Lock
45°
Default location of
Unlock
On
Local Manual Control
1
Off
Local Manual Control option
Speed control options
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
2
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 6, Page 9 of 9
March 2017
Date:
Q-Series
Hazardous area specifications
Modules QC41, QC42 and QC43
Below specification are applicable for QC41, QC42 and QC43 modules with a hazardous area approval.
Hazardous area product marking;
IECEx hazardous or Classified Location:
FM hazardous or Classified Location:
APPROVED
Ex d IIB+H2 T4/T6 Gb
Ex t IIIC T80°C Db
IECEx DEK 15.0034X
CL I, II, III, DIV 1
Groups BCDEFG, T4/T6, Type 4X/6
CL l, ZN 1, IIB+H2, T4/T6
CSA hazardous or Classified Location:
ATEX hazardous or Classified Location:
Class I, II, III, DIV 1
Groups CDEFG, T4/T6, Type 4X/6
Ex d IIB+H2 T4/T6
DIP A21 TA 80°C
CSA 12.2489009
1180
II 2G Ex db IIB+H2 T4/T6
II 2D Ex tb IIIC T80°C
DEKRA 15ATEX0055X
Notes:
1 Each control module is marked with the applicable ambient temperature marking.
2 Metric control modules are marked with ATEX and IECEx markings.
3 Imperial control modules are marked with ATEX, IECEx, FM and CSA markings.
Temperature rating
Table 7: Temperature rating for use in areas with a potential explosion hazard.
Configuration
Module type
Switch cartridge
QC41 (24VDC)
Temperature (°C)
Pneumatic
Max. Power
Min.
Max.
Max.
action
dissipation
ambient
ambient
Surface
S,D,F
3.6W (1
-25°C (-13°F)
+60
+80
T6/T4
S,D
3.6W (1
-25°C (-13°F)
+60
+80
T6/T4
F
7.2W (2
-25°C (-13°F)
+60
+80
T6/T4
Class
M, G
QC42, QC43 (115 or 230VAC)
O, C, N, H
QC42, QC43 (115 or 230VAC)
Notes:
Switch cartridge
1 1x or 2x 24VDC pilot valves, or 1x 115/230 VAC
pilot valve
2 2x 115 or 230 VAC pilot valves
M = Mechanical switches
G = Mechanical switches (gold contacts)
C = 3 wire PNP proximity switch
O = 3 wire NPN proximity switch
N = 2 wire proximity switch
H = 2 wire proximity switch
Pneumatic action
S = Spring Return (Single acting).
D = Double acting.
F = Double acting (Fail in Last Position)
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.13 - Rev: 3, Page 1 of 9
March 2017
Date:
Q-Series
Integrated Control modules
QC40 with AS-Interface digital bus communication.
Features
-
AS-Interface digital communication.
-
Up to 62 devices per segment for AS-Interface Spec. V3.0
protocol
-
Basic actuator functions for:
- Spring return applications, or
- Double acting applications or,
- Double acting Fail in Last Position applications.
-
Suitable for all Bettis actuator sizes both single and
double acting actuators.
-
Available as "Weather Proof" for indoors or outdoors
use and "Non-Arcing/Non-Incendive" for areas with a
potential explosion hazard.
- The robust aluminum alloy enclosure (IP66 /
NEMA4X rated), protects the IPT system, pneumatic
components, the feedback switches and terminals and
makes it suitable for indoor and outdoor use.
The hazardous area versions are available with:
- ATEX or IECEx Ex nA approvals for use in Zone
2, 21 and 22
- cFMus Non-Incendive approvals for use in Class I,
Division 2.
-
Operates with exchangeable position feedback switches.
-
Non-Intrusive switch point adjustment of the feedback
switches. Allows to adjust switch points without
opening the Control Module.
-
LED indicators for Fail, Power, Open and Close position.
-
Lockable Control Module cover.
-
All the control and feedback connections can be wired
through one single entry to the Control Module.
-
One larger entry (3/4"NPT) is available for larger
multi-core cables on imperial units.
-
Modular functionality for easy update towards
present and future bus systems.
Fig. 1. Control module QC40 with
ASI digital communication.
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.13 - Rev: 3, Page 2 of 9
March 2017
Date:
Q-Series
Description:
This Bettis Control Module offers an integrated concept
for valve automation. Its compact and robust construction
incorporates basic control and feedback functionality and
communicates through the AS-Interface Spec. V3.0, V2.11
protocol.
Terminal
Control Module
Option: 1 or 2
compartment
Type Label
speed control
throttles
Lockable
Module cover
Construction
All electrical and pneumatic control components are
located inside one module housing making it a compact
and robust construction incorporating basic control and
feedback functionality and is suitable for indoor and
outdoor use.
The Control Module is mounted at the side of the basic
actuator housing. Inside, wiring terminals are available for
connecting the AS-Interface signals. Two cable entries are
available.
One pneumatic connection is available to feed the control
module. The pilot valves inside the control module are
used to send the actuator to its open or closed position.
These modules are available with ATEX, IECEx or Inmetro
certification for use in Zone 2, 21, and 22, and additionally
FM certified for use in Class I, Division 2.
Pneumatic connections:
1/4”BSP or 1/4”NPT
Electrical entries:
LED's for Fail, Power, Open
3/4”NPT
and Close position
or M20
FAULT
1/2”NPT
or M20
Terminals for
AS-I bus signal
Option: Local
Manual Control
Option: Additional
Local Manual Control for “Fail
in Last Position”
Fig. 2. Control module overview
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.13 - Rev: 3, Page 3 of 9
March 2017
Date:
Q-Series
General specifications:
Communication Protocol:
Material housing:
Operating media:
Aluminium alloy
Air or inert gasses, filtered at 50µm
(for QC54 5µm)
Pneumatic entry:
Metric units: G1/4"
Imperial units:1/4”NPT
Electrical connections : Internal terminal strip for bus signal
Internal and external earth
connection
Optional quick connectors: 7/8" or
M12 connector (see page 9)
Cable entries:
Metric units: 2x M20x1.5
Imperial units:1/2” and 3/4"NPT
Enclosure:
Rated IP66 - NEMA4X
Switch points:
Factory set at 15° before each
end of travel
(open and closed position).
- Adjustable range:
Between -3° to 15° and +75° to
+93° of the end position.
Finish:
Chromated with polyurethane
based coating.
Temperature range:
G-Type switch: -25°C to +60°C
(-13°F to +140°F)
N-Type switch: -25°C to +60°C
(-13°F to +140°F)
Protocol:AS-Interface
Number of devices:
31 for AS-Interface Spec. V2.11 protocol
62 for AS-Interface Spec. V3.0 protocol
Current Minimum:
34 mA at 26.5V and 25°C
Maximum: 140 mA at 26.5V and 25°C
Nominal:
101 mA at 26.5V and 25°C
to 60°C
Protection: Short circuit detection
ASI-Profile V3.0:
S-6.A.E (other profiles optional)
Dimensions:
-
Metric:
Imperial/UNC:
DIN 3337:
See data sheet BQ1.603.08
See data sheet BQ1.603.09
See data sheet BQ1.603.10
Electrical safety requirements:
Use:
Altitude:
Maximum relative:
humidity
In- and outdoor.
Operating full power available up
to 2000 meter (6000 feet).
80% for temperatures up to 31°C
(87.8°F) decreasing linearly to 50%
relative humidity at 40°C (104°F).
Up to ±10% of nominal voltage
Table 1 - Factory settings:
Factory address
00
EID1
E/A-Code
6
EID2
E/A-Code
A
Parameter
Q-Series data bits
7
E
00
Functions
Type
DI’s
DO’s
D0
Bi-directional
Feedback “Closed”
Pilot Valve 2 Control
D1
Bi-directional
Feedback “Open”
Pilot Valve 1 Control
D2
Bi-directional
Not used
D3
Bi-directional
Not used
LED indicators for Open and Close position, Status,
and Power.
-
-
The Open and Close LED identify the position of the
automated valve. These LED's are also useful for setting
the switch points more accurately.
Status feedback is provided according to the ASI
standard For more detailed information on LED
indications, see Installation Guide : DOC.IG.BQC40.1
The power LED indicates if the AS-I cartridge is
powered or not.
Fault and Power LED
FAULT
POWER
Mains supply:
fluctuation
Over voltage category: II
Pollution degree:
2 (3 when the cover remains
closed)
Open and Close LED
Fig. 3. LED indicators
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.13 - Rev: 3, Page 4 of 9
March 2017
Date:
Q-Series
Pneumatic control
Pneumatic control variations
Terminals
The Control Module contains all the necessary pneumatic
components to control the actuator and control the
incoming and outgoing airflow. Pneumatically the modules
are available for three applications:
1 Spring return or
2 Double acting or
3 Double Acting - "Fail-in-Last-Position".
AS-I
Cartridge
Cable range:
0.2 - 2.5mm2 or 3012AWG
To achieve these functions, each Control Module can
be fitted with one or two pilot valves depending on the
required functionality:
1 One pilot valve is default and suitable for normal
operation of double acting or spring return actuators
2 Two pilot valves are required to achieve a "Fail-in-LastPosition" functionality on double acting actuators.
Pilot valve 1
Switch
cartridge
Fig. 5. One pilot valve and wiring connections for standard
Double Acting or Spring Return applications
Pneumatic
cartridge
Terminals
AS-I
Pilot valve 1
Cartridge
Cable range:
AS-I bus cartridge
Switch cartridge
Pilot valve 2
0.2 - 2.5mm2 or 3012AWG
Switch
cartridge
Fig. 4. Pilot valve and pneumatic cartridge
Fig. 6. Two pilot valves and wiring connections for Double
Acting "Fail in Last Position" applications
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.13 - Rev: 3, Page 5 of 9
March 2017
Date:
Pneumatic components
The pneumatic components inside the module consist
out of one or two pilot valves and a 3/2 spool valve or 5/2
bistable spool valve. The spool valves are pneumatically
operated by the pilot valves.
To assure trouble-free operation, the spool valves are
equipped with big ports. This enables a large air flow and
makes it less sensitive for contamination of the internals.
The large air flow also fast cycle times and enables it to be
utilized for the entire Bettis Q-Series actuator range.
Internal corrosion protection:
The spring return models have standard a built in
“Breather” function. During the spring stroke, the exhaust
air from the center chamber (A-Port) is first fed to the
spring chamber (B-port) preventing air from outside
from being sucked into the spring chamber. This reduces
the possibility of internal corrosion and maximizes the
actuators’ working life.
Q-Series
Fail safe
(spring return)
A-port
B-port
Option: Throttle 1
3/2 Spool valve
Option: LMC
Ps
Ra
Pilot valve 1
Double acting
Pneumatic options
Speed Control
The QC40 control module can be supplied with a Speed
Control option. One throttle is required for Spring Return
actuators and up to two for Double Acting actuators.
The speed control throttle controls the air flow in and
out of an air chamber and as such limits the speed of the
“Opening” and “Closing” stroke simultaneously.
A-port
B-port
Option:
Throttle 1
Option:
Throttle 2
5/2 Spool valve
Option: LMC
Rb
Ps
Ra
Silencers and vents
Pilot valve 1
The exhaust ports Ra and Rb on the module are shipped
from the factory with transport protection.
The module can be equipped with either silencers or vents.
Manual Control
For commissioning, emergency or maintenance purposes,
the QC40 control module can be supplied with Manual
Control options. These options can operate the actuator
when there is air pressure available, but no control signal
or power supply.
- For normal operation the module should be fitted with
one Manual Control.
- For Double Acting with a Fail-in-Last-Position function,
two Manual Control can be fitted.
Double Acting
Fail in Last
Position
A-port
Option:
Throttle 1
B-port
Option:
Throttle 2
5/2 Spool valve
Option: LMC 1
Option: LMC 2
Maximum Flow Rates of Q-Series Modules
The maximum flow rates depends mainly on the flow rates
of the Bettis Q-Series modules. You can use Kv 0.28 (m3/h)
or Cv value of 0.33 (US gall/min 1 Psi) for approximate
operating speed calculations.
Ps
Rb
Ra
Pilot valve 1
Fig. 7. Pneumatic operation
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Pilot valve 2
Product data sheet
Sheet No.: BQ1.604.13 - Rev: 3, Page 6 of 9
March 2017
Date:
Q-Series
Position feedback
The position feedback is achieved by switch cartridges
in the module. These cartridges contain switching
elements which sense the open or closed position and
are pre wired to the AS-I cartridge (see fig 5 and 6). These
easily exchangeable switch cartridges are available with
mechanical or proximity switching elements.
If required the switches can be adjusted without opening
the module. This, so called, Non-Intrusive switch
adjustment is located at the front of the module behind
a locable (1) shield (2). Two adjustment screws are
available for adjusting the Closed (3) and Open (4) position
N WHEN E
indication.
NING N
PE
O AR
!
-W
-
IZED
DO NO
T
Non-Intrusive switch point adjustment
G
ER
Switch cartridges
Terminal strip position
feedback switches
3
4
1
2
Switch cartridge
Fig. 8. Switch cartridges
"Closed"
Switch point adjustment
Mechanical switches
Table 2: Mechanical switches
Specification
Description
Option code
G (gold contacts)
Type
Mechanical
Contacts
NO and NC
Temperature range
-25°C to +60°C / -13°F to +140°F
2-Wire Proximity switches
Table 4: 2-wire NAMUR proximity switches
Specification
Description
Option code
N
Type
2-wire inductive, normally closed
Temperature range
-25°C to +60°C / -13°F to +140°F
Compliant to
DIN EN 60947-5-6 (NAMUR)
Note:
1. The switch cartridge is internal powered by AS-i
cartridge, external power/wire for switch signal is not
required.
"Open"
Switch point adjustment
Fig. 9. Non-Intrusive switch point adjustment
Important:
-
-
The above "Closed" and "Open" marked adjustment
screws will adjust the valve's "Closed" or "Open" switch
point, if the valve closes after a Clock Wise (CW)
rotation.
If the valve closes after a Counter Clock Wise (CCW)
rotation, the "Closed" marked adjustment screw will
adjust the "Open" switch point. Similar, the "Open"
marked adjustment screw will adjust the "Closed"
switch point.
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.13 - Rev: 3, Page 7 of 9
March 2017
Date:
Q-Series
Control Module Options
Local Manual Control
Speed Control
Description
Description
For commissioning, emergency or maintenance purposes,
the QC40 control module can be supplied with one or
two Manual Control options. These can operate the
spool valve(s) inside the module and as such operate
the actuator, when there is air pressure available, but no
control signal or power supply.
The QC40 control module can be supplied with a Speed
Control option. One throttle is required for Spring Return
actuators and up to two for Double Acting actuators.
The speed control throttle controls the air flow in and
out of an air chamber and as such limits the speed of
the “Opening” and “Closing” stroke simultaneously. This
throttle consists of :
1 Nut cover
2 Main throttle with set screw.
Notes:
-
-
-
-
One Local Manual Control is required for normal
operation of Double acting or Spring return actuators.
For Double acting actuator with a Fail-in-last position
function, a second Local Manual Control can be
mounted.
These options can be ordered together with the
Control Module or as a kit to be mounted later.
For option ordering codes, see page 7
Notes:
-
-
-
For Spring Return actuators with one speed control
throttle, it is not possible to set both the stroke cycle
times to an equal time.
Four Double Acting actuators it is possible to mount
two speed control throttles.
The actual stroke cycle times depend on the actual
load on the actuator during the different strokes.
Spring Return:
Top entry only.
Double Acting:
Bottom and/or top entries.
Location for 2nd
Local Manual Control
On
45°
Default location of
Local Manual Control
Off
Lock
1
Unlock
Fig. 10. Local Manual Control option
Fig. 11. Speed control options
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
2
Product data sheet
Sheet No.: BQ1.604.13 - Rev: 3, Page 8 of 9
March 2017
Date:
Q-Series
Hazardous area executions
Control Module QC40 with AS-I bus communication is available with optional Non-Incendive/Non Sparking (NI)
approvals as listed below:
IECEx
ATEX
FM
Certificate No.: IECEx DEK 16.0061 X
Certificate No.: DEKRA 16ATEX0100 X
Certificate No.: FM16US0367X
Non-Sparking
Non-Sparking
Non Incendive
Ex nA IIC T4 Gc
Ex tb IIIC T80°C Db
-
II 3 G Ex nA IIC T4 Gc
II 2 D Ex tb IIIC T80°C Db
-
Class I, II, III, Division 2,
Groups ABCDEFG, T4,
Class 1, Zone 2 AEX nA IIC
T4 Gc
Ambient temperature:
T4 @ Ta = -25°C...+60°C IP66/Nema 4X
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.13 - Rev: 3, Page 9 of 9
March 2017
Date:
Q-Series
Wiring and Quick Connectors
AS-I Bus terminal wiring
Wiring for hazardous areas
The QC40 module can be connected to the system by hard
wiring the module to the terminals The QC40 Module can
optionally be equipped with prewired quick connectors.
Two versions are available: 7/8” or M12 (male chassis part).
Detailed safe area, Intrinsically safe or Non-Incendive/
Non-Sparking wiring instructions, will be shipped with the
product, see Installation Guide : DOC.IG.BQC40.1
Field wiring
Actuator wiring
2
Minimum:
Maximum:
Nominal:
Protection:
Quick connector pinouts:
(male chassis part)
3
4
1
2
4
2
7/8" UNC
3
2
4
1
Blue
34 mA at 26.5V and 25°C
140 mA at 26.5V and 25°C
101 mA at 26.5V and 25°C
to 60°C
Short circuit detection.
1
Brown
2
Green/Yellow
M12
Quick
connector
Wiring dimensions
Current
- 3
Fig 12. QC40 AS-I module wiring
1
Quick connectors, as shown are excluded for non-Incendive
or non-sparking use in hazardous area’s classified as Zone 2
or 22 or Cl I, II, III, Div. 2.
Solid wire:
2.5mm2 max.
Stranded wire: 0.2-3.3mm2 or 24-12 AWG
+ 1
AS-I
Power
supply
Quick connectors
3
Terminal
Note:
Terminal 2 may be used for shield.
Fig 13. QC40 AS-I module quick connector pinouts
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 1, Page 1 of 13
March 2017
Date:
Q-Series
Integrated Control modules
QC54 with FOUNDATION™ Fieldbus digital communication.
Features:
-
Basic actuator functions for:
- Spring return applications, or
- Double acting applications or,
- Double acting Fail in Last Position applications.
-
Suitable for all Q-Series actuator sizes.
-
FOUNDATION™-Fieldbus digital communication.
-
IPT-technology (Intelligent Position Tracking).
-
Initialization by FOUNDATION™- Fieldbus or Push Button
for easy setup of the actuator.
- Press and confirm press the "Auto-Init" button starts
auto-initialization procedure.
- Initialization sets automatically the switch points for
the position feedback of the actuator.
- Initialization checks if the actuator and control module
configuration match. This procedure will detect the
action type (Fail-Open, Fail-Close or Fail in last position)
and generate an alert if there is a configuration issue.
-
Readjustable or Reversible position feedback using the
re-reassignment buttons or by FOUNDATION™ Fieldbus.
-
Adjustable switch points can be adjusted from 5% to 30%
before the end of the stroke by FOUNDATION™ Fieldbus.
-
Three indication LED's for "Status", "Open" and "Closed"
position. Status LED indicates:
- Initialization procedure running (blinking),
- Successful initialization procedure (LED is on) or
- No or failed initialization (flashing) or
- A particular unit in the field.
-
Control Module can be easily mounted to the actuator
Fig. 1. Control module QC54 with
FOUNDATION™-Fieldbus bus communication
-
Available as "Weather Proof" for indoors or
outdoors use.
- The robust aluminum alloy enclosure (IP66/
NEMA4X rated), protects the IPT system, pneumatic
components, the feedback switches and terminals and
makes it suitable for indoor and outdoor use.
The hazardous area versions are available with:
- ATEX or IECEx Ex ia or Ex nA approvals for use in Zone
1, 2, 21 and 22
- cFMus Intrinsically safe or Non-Incendive approvals
for use in Class I, Division 1 or Class I, Division 2.
-
Lockable Control Module cover.
-
One larger entry (3/4"NPT) is available for larger multicore cables on imperial units.
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 1, Page 2 of 13
March 2017
Date:
Q-Series
Description:
This Q-Series QC54 Control Module offers an integrated
concept for valve automation. Its compact and
robust construction incorporates basic control and
feedback functionality and communicates through the
FOUNDATION™- Fieldbus protocol.
All electrical and pneumatic control components are
located inside one module housing making it a compact
and robust construction incorporating basic control and
feedback functionality and is suitable for indoor and
outdoor use.
Construction:
The Control Module is mounted at the side of the basic
actuator housing. Inside, wiring terminals are available for
connecting the FOUNDATION™- Fieldbus signals. Two cable
entries are available.
One pneumatic connection is available to feed the control
module. The pilot valves inside the control module are
used to send the actuator to its open or closed position.
Terminal
Control Module
Option: 1 or 2
compartment
Type Label
speed control
throttles
Lockable
Module cover
Pneumatic connections:
1/4”BSP or 1/4”NPT
Last Position”
Electrical entries:
Button board
3/4”NPT
or M20
1/2”NPT
or M20
Terminals
bus signal
Option: Local
Manual Control
Option: Additional Local
Manual Control for “Fail in
Fig. 2. Control module overview
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 1, Page 3 of 13
March 2017
Date:
Q-Series
General specifications:
Communication Protocol:
Material housing:
Aluminium alloy
Operating media:
Air or inert gasses, filtered at 5µm
Pneumatic entry:
Metric units: G1/4"
Imperial units:1/4”NPT
Electrical connections : Internal 3 pole terminal strip for
bus signal
Internal and external earth
connection
Optional quick connectors: 7/8" or
M12 connector (see page 9)
Cable entries:
Metric units: 2x M20x1.5
Imperial units:1/2” and 3/4"NPT
Enclosure:
Rated IP66 - NEMA4X
Switch points:
Factory set at 15° before each
end of travel (open and closed
position).
- Adjustable range:
Between -3° to 15° and +75° to
+93° of the end position.
Finish:
Chromated with polyurethane
based coating.
Temperature range:
-20°C to +50°C (-4°F to +122°F)
Protocol :
Transmission : Maximum current : Required external : protection current Dimensions:
Metric:
Imperial/UNC:
DIN 3337:
See data sheet 1.603.08
See data sheet 1.603.09
See data sheet 1.603.10
Electrical safety requirements:
Use:
Altitude:
Maximum relative:
humidity
FOUNDATION™-Fieldbus
H1, IEC 61158-2
18mA from bus
Restrict the power supply
to <600mA.
Function blocks
The Control Module provides the following function blocks:
- Resource Block (RB)
- Transducer Block (TB)
- Analog Input (AI) Function Block
- Discrete Output (DO) Function Block
- 2x Discrete Input (DI) Function Block
- PID Function Block
Diagnostics and Alerts
Standard FOUNDATION™- Fieldbus diagnostics and alerts
provided meets Emerson PlantWeb Alerts standard.
Applicable diagnostics include:
- Travel times for the Open stroke, Close stroke and
Average travel times.
- Cycle Counters for Control Module, Pneumatic Module,
Actuator and Valve
- Time in Position
- Various internal electronic health tests.
- Instrument temperature.
For more detailed information on diagnostics see page 10
and 11.
In- and outdoor.
Operating full power available up
to 2000 meter (6000 feet).
80% for temperatures up to 31°C
(87.8°F) decreasing linearly to 50%
relative humidity at 40°C (104°F).
Up to ±10% of nominal voltage
Mains supply:
fluctuation
Over voltage category: II
Pollution degree:
2 (3 when the cover remains
closed)
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 1, Page 4 of 13
March 2017
Date:
Q-Series
Pneumatic control
Pneumatic control variations
Terminals
The Control Module contains all the necessary pneumatic
components to control the actuator and control the
incoming and outgoing airflow. Pneumatically the modules
are available for three applications:
1 Spring return or
2 Double acting or
3 Double Acting - "Fail-in-Last-Position".
To achieve these functions, each Control Module can
be fitted with one or two pilot valves depending on the
required functionality:
1 One pilot valve is default and suitable for normal
operation of double acting or spring return actuators
2 Two pilot valves are required to achieve a "Fail-in-LastPosition" functionality on double acting actuators.
FOUNDATION
Field bus
Cartridge
Pilot valve 1
Cable range:
0.33 - 2.5mm2 or 22 - 12AWG
Fig. 4. One pilot valve and wiring connections for standard
Double Acting or Spring Return applications
Terminals
FOUNDATION
Pilot valve 1
Field bus
Cartridge
Pilot valve 2
Cable range:
0.33 - 2.5mm2 or 22 - 12AWG
Pneumatic cartridge
FOUNDATION™
Fieldbus cartridge
Terminals
bus signal
Fig. 5. Two pilot valves and wiring connections for Double
Acting "Fail in Last Position" applications
Fig. 3. Pilot valve and pneumatic cartridge
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 1, Page 5 of 13
March 2017
Date:
Pneumatic components
The pneumatic components inside the module consist
out of one or two pilot valves and a 3/2 spool valve or 5/2
bistable spool valve. The spool valves are pneumatically
operated by the pilot valves.
To assure trouble-free operation, the spool valves are
equipped with big ports. This enables a large air flow and
makes it less sensitive for contamination of the internals.
The large air flow also fast cycle times and enables it to be
utilized for the entire Q-Series Series actuator range.
Internal corrosion protection:
The spring return models have standard a built in
“Breather” function. During the spring stroke, the exhaust
air from the center chamber (A-Port) is first fed to the
spring chamber (B-port) preventing air from outside
from being sucked into the spring chamber. This reduces
the possibility of internal corrosion and maximizes the
actuators’ working life.
Q-Series
Fail safe
(spring return)
A-port
B-port
Option: Throttle 1
3/2 Spool valve
Option: LMC
Ps
Ra
Pilot valve 1
Double acting
Pneumatic options
Speed Control
The QC54 control module can be supplied with a Speed
Control option. One throttle is required for Spring Return
actuators and up to two for Double Acting actuators.
The speed control throttle controls the air flow in and
out of an air chamber and as such limits the speed of the
“Opening” and “Closing” stroke simultaneously.
A-port
B-port
Option:
Throttle 1
Option:
Throttle 2
5/2 Spool valve
Option: LMC
Rb
Ps
Ra
Silencers and vents
Pilot valve 1
The exhaust ports Ra and Rb on the module are shipped
from the factory with transport protection.
The module can be equipped with either silencers or vents.
Manual Control
For commissioning, emergency or maintenance purposes,
the QC54 control module can be supplied with Manual
Control options. These options can operate the actuator
when there is air pressure available, but no control signal
or power supply.
- For normal operation the module should be fitted with
one Manual Control.
- For Double Acting with a Fail-in-Last-Position function,
two Manual Control can be fitted.
Double Acting
Fail in Last
Position
A-port
Option:
Throttle 1
B-port
Option:
Throttle 2
5/2 Spool valve
Option: LMC 1
Option: LMC 2
Maximum Flow rates of Q-Series modules
The maximum flow rates depends mainly on the flow rates
of the Bettis Q-Series modules. You can use Kv 0.28 (m3/h)
of Cv value of 0.33 (US gall/min 1Psi) for approximate
operating speed calculations.
Ps
Rb
Ra
Pilot valve 1
Fig. 6. Pneumatic operation
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Pilot valve 2
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 1, Page 6 of 13
March 2017
Date:
Q-Series
Switch point setting
The QC54 control modules are equipped with a button
board that allows you to set or readjust the switch points
for the position feed back.
Closed reassignment button
Status LED
Press and
Open reassignment button
confirm press
on
LED = Flashing
off
Auto-Initialization
Initialization sets automatically the switch points for
the position feedback of the actuator and checks if the
actuator and control module configuration match. This
procedure will detect the action type (Fail-Open, Fail-Close
or Fail in last position) and generate an alert if there are
configuration issues.
This process is done automatically, by the module,
however, the user must start it and the unit must be wired
and powered.
Digital communication is not required but power supply
is necessary (9V to 32V DC). The initialization process can
be started in one of two ways:
1. Initialization using the local buttons (see fig. 7).
2. Initialization using a bus command (see Reference
manual QC54, DOC.RM.QC54.E)
Indication LED's
on
LED = Blinking
off
Time
* The default setting of The reassignment buttons is: enabled when
the unit is in “Out of Service”.
Recognize Function
* ”Open” and “Closed” LED are disabled.
Fig. 7. Button board
Button board functions:
Initialization button:
Start Auto-Initialization procedure
Re-adjustment of the "Closed" switch point
Close button:
Set to factory settings
Re-adjustment of the "Closed" switch point
Open button:
Set to factory settings
End stop
end position
offsets
End stop offsets
An additional function of the Status LED is the recognize
function. To recognzie a particular unit in the plant,
the "Recognizing LED" function can be activated in the
transducer block. When this function is activated, the
Status LED will blink for 300 seconds (5 minutes).
Changing Switch Point Setting
Readjustment of switch points
10°max
“Close”
end
±40°
±40°
Three indication LED's for "Status", "Open" and "Closed"
position are available. The status LED indicates:
- Initialization procedure running (blinking),
- Successful initialization procedure (LED is on) or
- No or failed initialization (flashing)
10°max
When switch point re-adjustment is required but it is
not allowed that the actuator/valve unit cycles, the new
switch point can be set by pressing the corresponding
"Open" or "Closed" button.
Factory settings
Pressing both the Open and Close reassignment buttons,
while powering up, will set the module back to its factory
settings.
position
“Open”
Factory settings
Setting after initialization
Fig. 8. Switch point setting
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 1, Page 7 of 13
March 2017
Date:
Q-Series
Control Module Options
Local Manual Control
Speed Control
Description
Description
For commissioning, emergency or maintenance purposes,
the QC54 control module can be supplied with one or
two Manual Control options. These can operate the
pilot valve(s) inside the module and as such operate the
actuator, when there is air pressure available, but no
control signal or power supply.
Notes:
-
-
-
-
One Local Manual Control is required for normal
operation of Double acting or Spring return actuators.
For Double acting actuator with a Fail-in-last position
function, a second Local Manual Control can be
mounted.
These options can be ordered together with the
Control Module or as a kit to be mounted later.
For option ordering codes,
see data sheet BQ1.607.01
The QC54 control module can be supplied with a Speed
Control option. One throttle is required for Spring Return
actuators and up to two for Double Acting actuators.
The speed control throttle controls the air flow in and
out of an air chamber and as such limits the speed of
the “Opening” and “Closing” stroke simultaneously. This
throttle consists of :
1 Nut cover
2 Main throttle with set screw.
Note:
-
-
-
For Spring Return actuators with one speed control
throttle, it is not possible to set both the stroke cycle
times to an equal time.
Four Double Acting actuators it is possible to mount
two speed control throttles.
The actual stroke cycle times depend on the actual
load on the actuator during the different strokes.
Spring Return:
Top entry only.
Double Acting:
Location for 2nd
Bottom and/or top entries.
Local Manual Control
Lock
45°
Default location of
Local Manual Control
Unlock
On
1
Off
Fig. 9. Local Manual Control option
Fig. 10. Speed control options
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
2
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 1, Page 8 of 13
March 2017
Date:
Q-Series
Wiring and Quick Connectors
FOUNDATION™ Fieldbus terminal wiring
Wiring for hazardous areas
The QC54 module can be connected to the system by hard
wiring the module to the terminals The QC54 Module can
optionally be equipped with prewired quick connectors.
Two versions are available: 7/8” or M12 (male chassis part).
Detailed safe area, Intrinsically safe or Non-Incendive/
Non-Sparking wiring instructions, will be shipped with the
product, see Installation Guide : DOC.IG.BQC54.1
Quick connectors
Field wiring
Quick connectors, as shown are excluded for non-Incendive
or non-sparking use in hazardous area’s classified as Zone 2
or 22 or Cl I, II, III, Div. 2.
Actuator wiring
+ 1
FF
Power
supply
Wiring dimensions
2
- 3
Solid wire Stranded wire
:2.5mm2 max.
:0.33 - 2.5mm2 or 22 - 12 AWG
Quick connector pinouts:
(male chassis part)
1
3
2
4
7/8" UNC
4
1
3
2
2
4
1
Blue
1
Brown
2
Green/Yellow
M12
Quick
connector
3
Terminal
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 2, Page 9 of 13
Date:
April 2017
Q-Series
Hazardous area executions
Control Module QC54 with FOUNDATION™ Fieldbus is available with optional intrinsically safe (IS) or Non-Incendive/
Non Sparking (NI) approvals as listed below:
IECEx
ATEX
FM
Certificate No.:
IECEx DEK16.0032X
Certificate No.:
DEKRA 16ATEX0064X
Certificate No.:
FM16US0367X
Intrinsically safe*
Intrinsically safe*
Type 4X
Ex ia IIC T4 Ga
Ex ia IIIC T80°C Da
Ex ic IIC T4 Gc
Non-Sparking
Ex nA IIC T4 Gc
Ex tb IIIC T80°C Db
II 1 G Ex ia IIC T4 Ga
II 1 D Ex ia IIIC T80°C Da
II 3 G Ex ic IIC T4 Gc
Non-Sparking
II 2 D Ex tb IIIC T80°C Db
II 3 G Ex nA IIC T4 Gc
Intrinsically safe*
-
-
Intrinsically safe,Class I, II, III Div.1,
Groups ABCDEFG, T4,
Type4/IP66
Class 1, Zone 1, AEx ia IIC T4
Non Incendive
-
-
Class I, II, III, Division 2,
Groups ABCDFG, T4
Class 1, Zone 2, Group IIC T4
CSA
Ambient temperature:
T4 @ Ta = -20°C...+50°C IP66/nema 4x
Note:
* The assembly of a Q-Series Actuator with the intrinsically safe QC54 Control Module, may be used in (ATEX) classified
Zones 1, 2(Gasses) and/or 21, 22 dust(Dust).
FISCO systems
The Q-Series QC54 is suitable for use in a FISCO system in accordance with IEC 60079-27
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 1, Page 10 of 13
March 2017
Date:
Q-Series
Diagnostics and PlantWeb Alerts
QC54 FOUNDATION™ Fieldbus
Diagnostics
PlantWeb Alerts
The Q-Series QC54 Control Module with FOUNDATION™
Fieldbus communication has diagnostic capabilities.
These process parameters can give information about
communication condition, valve and/or actuator unit.
It enables to predict failures in advance and makes
maintenance easier to schedule. The following diagnostics
are available for the QC54 control module:
PlantWeb Alerts are alerts that have been predefined and
categorized for the user. These device alerts can be used to
help troubleshoot the instrument (see also page 4). There
are three categories:
-
Failed alerts,
A failed alert indicates a failure within the device that
will make the device, or some part of the device, nonoperational.
1 Timer parameters:
1. Open and Closed travel time
2. High and low limits of Open and Closed travel time
3. Average travel times of last 30 strokes of Open and Closed travel.
4. High and low limits of average Open and Closed
travel time
-
Maintenance alerts
A maintenance alert indicates that the device, or some
part of the device, needs maintenance soon.
-
Advisory alerts
An advisory alert indicates a condition that does not
have a direct impact on the device’s primary function.
If the condition is ignored, the device will eventually
fail.
2 Cycle Counters
1. Control Module - Counts how many times the Control Module cycles (read only).
2. Pneumatic Module - Counts how many times the Pneumatic Module cycles.
3. Actuator - Counts how many times the actuator cycles.
4. Valve - Counts how many times the valve cycles.
3
Time In Position
4
Various internal electronic health tests.
These alerts, when enabled, can participate in the DeltaV
alarm interface tools such as the alarm banner, alarm list,
and alarm summary.
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 1, Page 11 of 13
March 2017
Date:
Q-Series
Diagnostics and PlantWeb Alerts
Alerts & recommended actions
Alert default setting
Alerts
DeltaV text
Recommended actions
enable
mask
(show)
enable
mask
(show)
Fail
mask
(show)
Maintenance
enable
Advisory
bad_position_sensor
Bad Position Sensor Error
Feedback problem, replace control module
when possible
n
n
y
y
n
n
bad_temperature_sensor
Bad Temperature Sensor
Error
Temperature sensor problem, replace Control module when possible
n
n
y
y
n
n
system_temperature_exceeded System Temperature
Exceeded
Take corrective actions to bring temperature
within specified range.
n
n
y
y
n
n
software_error
Software Error
Software error has been detected, replace
control module when possible.
n
n
y
n
n
n
travel_deviation
Travel Deviation
Lost position, Check air pressure
y
y
n
n
n
n
shutdown_is_set
Shutdown Is Set
Internal communications problem, check
shutdown configuration for restart, Replace
Control module.
pilot valve number mismatch or pilot valve
failure has been detected
n
n
n
n
y
y
n
n
y
y
n
n
Error is undefined, replace control module
when possible
n
n
y
n
n
n
cm_life_exceeded
Control Module Life Cycle Control module life cycle exceeded, replace
Exceeded
control module
n
n
y
y
n
n
pm_life_exceeded
Pneumatic Module Life
Cycle Exceeded
Pneumatic module life cycle exceeded,
replace pneumatic module.
n
n
n
n
n
n
act_life_exceeded
Actuator Life Cycle
Exceeded
Actuator life cycle exceeded, replace actuator.
n
n
n
n
n
n
valve_life_exceeded
Valve Life Cycle Exceeded
Valve life cycle exceeded,valve requires
maintenance.
n
n
n
n
n
n
Parameter name
Internal alerts
pilot valve_error
Pilot valve error
Buttonboard_error
Buttonboard Error
Counter alerts
Timer alerts
time_in_position_exceeded
Time in position exceeded Time in position exceeded, take appropriate
action.
n
n
n
n
n
n
open_travel_time_exceeded
Open travel timer exceeded
Open travel timer exceeded, check valve
system.
n
n
n
n
n
n
close_travel_time_exceeded
Close travel timer exceeded
Close travel timer exceeded, check valve
system.
n
n
n
n
n
n
assembly error
Assembly error
pneumatic function mismatch, check module and actuator configuration
n
n
y
y
n
n
initialization_failed
Initialization Failure
Device failed initialization; Check airpressure, check actuator sizing, check valve
system
y
y
n
n
n
n
Initialization alert
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 1, Page 12 of 13
March 2017
Date:
Q-Series
Alerts & recommended actions (continued)
Alert default setting
Alerts
mask
(show)
enable
mask
(show)
Recommended actions
enable
DeltaV text
Fail
mask
(show)
Parameter name
Maintenance
enable
Advisory
y
y
n
n
n
n
n
n
n
n
y
y
n
n
n
n
y
y
y
y
n
n
n
n
y
y
n
n
n
n
Internal IO failure alert
io_failure
rb_NV_write_deferred
Internal Io Failure
Internal communications are lost, device will
act according to shutdown configuration.
Output Board NV Memory NV Write Deferred:
Failure
A high number of writes has been detected
to non-volatile memory. To prevent premature failure of the memory, the write
operations have been deferred. The data will
be saved about every 3 hours.
This condition usually exists because a program has been written that writes to control
block parameters not normally expected
to be written to on a cyclic basis. Any such
automated write sequence should be modified to write the the parameter(s) only when
needed.
diag_opt_PWA_simulate
It is recommended that you limit the
number of periodic writes to all static or
non-volatile parameters such as HI_HI_LIM,
LOW_CUT, SP, TRACK_IN_D, OUT, IO_OPTS,
BIAS, STATUS_OPTS, SP_HI_LIM, and so on.
PWA Simulate Active
If PWA simulate mode has been activated.
The PWA active parameters can now be
written as well as the resource block detailed
status parameters and the internal alerts in
the Transducer Block where the PWA active
alarms originate from.
Output Board NV Memory "Output Board NV Memory Failure:
Failure
Non-volatile EEPROM data corruption was
detected on the Fieldbus Electronics Board.
Default values were loaded into the faulty
block.
1. Check the device configuration for
changes in the block parameter values.
2. Reset the device to clear the error.
3. Download a Device Configuration.
NOTE: If the failure reoccurs it may indicate
a faulty EEPROM memory chip."
Output Board Electronics Output Board Electronics Failure:
Failure
The Device has detected a fault with an electrical component on the Fieldbus Electronics
Module Assembly. Replace the Device.
PWA Simulate
func_opt_simulate
Simulate Switch
misc_opt_base_record
Base Record
PWA_simulate_active
rb_nv_memory_failure
rb_nv_electronics_failure
Since the hardware simulate switch may be
impractical to access, a software option is
being provided.
When the base record option is enabled,
operator can write/read parameters to/from
the sensor board that are not available via
the FF parameter list.
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 1, Page 13 of 13
March 2017
Date:
Q-Series
Namur NE-107 Alarms
This section describes the parameter interaction to implement
a Bettis Q-Series QC54 Control module to the NAMUR NE-107
requirements as a parameter group in the Resource Block.
There are four alarm categories defined as per the NE-107
specification, Failed, Off Specification, Maintenance, and Check
function.
Maintenance Although the output signal is valid, the
wear reserve is nearly exhausted or a functions will soon
be restricted due to operational conditions e.g. build-up of
deposits
Off Specification Off-spec means that the device is operating
outside its specified range or an internal diagnostic indicates
deviations from measured or set values due to internal
problems in the device or process characteristics (e.g. bubble
formation in flow metering or valve sticking).
Check Function Output signal temporarily invalid (e.g. frozen)
due to on-going work on the device.
Failed Output signal invalid due to malfunction in the field
device or its peripherals.
Parameter
Mnemonic
FD_CHECK_ACTIVE
Obj
Type
S
Data Type/
Structure
Bit String
Use/Model
Store
Each of these categories share 32 conditions that can be
defined by the device manufacturer. Each condition may
be mapped or not mapped for each category. If a condition
is mapped then it is indicated in the* ACTIVE parameter. If
the condition in the * ACTIVE parameter is not masked by
the corresponding bit in the *_MASK parameter then the
condition will be queued for broadcast using the corresponding
*ALM parameter at the associated priority indicated by *PRI
parameter. The 4 categories are defined below.
The conditions are not expected to identify explicitly the root
cause of the condition, but rather to identify it in terms of:
•Replace the device
•Replace a part of the device
•Correct a configuration problem
•Fix something outside of the device
The above list is all that the operator needs to know to restore
his process functionality and if there are more than 31 device
conditions they should be grouped by definition into these bit
Size
Valid
Range
Initial
Value
C/FD Active
D
4
FD_CHECK_ALM
R
DS-87
C/Alarm
D
15
FD_CHECK_MAP
S
Bit String
C/Contained
S
4
FD_CHECK_MASK
S
Bit String
C/Contained
S
4
FD_CHECK_PRI
S
Unsigned8
C/Alert Priority
S
1
FD_EXTENDED_ACTIVE_n
S
Bit String
C/Contained
D
4
FD_EXTENDED_MAP_n
S
Bit String
C/Contained
S
4
FD_FAIL_ACTIVE
S
Bit String
C/FD Active
D
4
FD_FAIL_ALM
R
DS-87
C/Alarm
D
15
FD_FAIL_MAP
S
Bit String
C/Contained
S
4
FD_FAIL_MASK
S
Bit String
C/Contained
S
4
FD_FAIL_PRI
S
Unsigned8
C/Alert Priority
S
1
FD_MAINT_ACTIVE
S
Bit String
C/FD Active
D
4
FD_MAINT_ALM
R
DS-87
C/Alarm
D
15
FD_MAINT_MAP
S
Bit String
C/Contained
S
4
FD_MAINT_MASK
S
Bit String
C/Contained
S
4
FD_MAINT_PRI
S
Unsigned8
C/Alert Priority
S
1
FD_OFFSPEC_ACTIVE
S
Bit String
C/FD Active
D
4
FD_OFFSPEC_ALM
R
DS-87
C/Alarm
D
15
FD_OFFSPEC_MAP
S
Bit String
C/Contained
S
4
FD_OFFSPEC_MASK
S
Bit String
C/Contained
S
4
FD_OFFSPEC_PRI
S
Unsigned8
C/Alert Priority
S
1
0 - 15
0
FD_RECOMMEN_ACT
S
Unsigned16
C/Contained
D
2
1 – manf
spec
0
FD_SIMULATE
R
DS-89
C/FD Simulate
D
9
FD_VER
S
Unsigned16
C/Contained
S
2
Permission
Other
Range
Check
Read only
ALARM
ALARM
0 - 15
0
ALARM
Yes
Read only
Read only
ALARM
ALARM
0 - 15
0
ALARM
Yes
Read only
ALARM
ALARM
0 - 15
0
ALARM
Yes
Read only
ALARM
ALARM
ALARM
Yes
Read only
disabled
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Read only
Product data sheet
Sheet No.: BQ1.606.01 - Rev: 1, Page 1 of 2
Date:
January 2017
Q-Series
Bettis Q-Series valve actuator
Parts and materials - Actuator
Description
Qty.Description
Specification
Notes
1/5
Body
1
Aluminum Alloy
EN AC-AlSi10Mg (Cu)
Pinion
1
Aluminum Alloy
EN AW 7075 T6
2
Upper pinion part
1
Aluminum Alloy
EN AW 7075 T6
2
Guide band housing
2*
Nylatron
PA6.6 + MoS2
-
Washer pinion
2*
CRMZX100
-
Bearing ring
2*
Delrin®POM
Limit stop cam
1
Steel
42CrMo4V
-
Piston
2
Aluminum Alloy
EN AC-AlSi7Mg
6
End cap QS
2
Aluminum Alloy
EN AC-AlSi7Mg
1
End cap QD
2
Aluminum Alloy
EN AC-AlSi7Mg
1
Guide band piston
2*
PTFE, Carbon filled
PTFE + 25% C
-
O-ring piston
2*
Nitrile Rubber
NBR
-
O-ring end cap
2*
Nitrile Rubber
NBR
-
O-ring upper pinion part
1*
Nitrile Rubber
NBR
-
O-ring pinion top
1*
Nitrile Rubber
NBR
-
O-ring pinion bottom
1*
Nitrile Rubber
NBR
-
O-ring B-port
2*
Nitrile Rubber
NBR
-
O-ring retainer bolt
4*
Nitrile Rubber
NBR
-
O-ring limit stop bolt
2*
Nitrile Rubber
NBR
-
Outer spring
2
Carbon Spring Steel
EN 10270-1 SH
3
Middle spring
2
Carbon Spring Steel
EN 10270-1 SH
3
Inner spring
2
Carbon Spring Steel
EN 10270-1 SH
3
Spring retainer
2
Steel
St. DC01 EN10139
4
Washer springpack
2
Steel
C35
4
Springpack retainer bolt
2
Stainless Steel
AISI 304 (DIN W nr 1.4301)
-
Washer
4*Nylon
PA6
-
Nut
4
Stainless Steel
AISI 304 (DIN W nr 1.4301)
-
Nut cover
2
Polyethylene
PE
-
End cap screws
8
Stainless Steel
AISI 304 (DIN W nr 1.4301)
-
Retaining ring pinion large
1*
Carbon Spring Steel
C45, DIN 17200
3
Retaining ring pinion small
1*
Carbon Spring Steel
C45, DIN 17200
3
Limit stop screw
1
Stainless Steel
AISI 304 (DIN W nr 1.4301)
-
Indicator cap
1
Nylon
PA6
-
Indicator arrow
1
Nylon
PA6
-
Indicator insert
1
Nylon
PA6
-
Type plate
1
Stainless Steel
AISI 303 (DIN W nr 1.4305)
-
Hammer drive
1
Stainless Steel
AISI 303 (DIN W nr 1.4305)
-
Insert
1
Aluminum Alloy
EN AW 6082 T5
5
-
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Notes
1 See Corrosion protection
below
2 Hard anodized.
3Deltatone® or Epoxy
(black) coating.
4 Zinc plated and
passivated.
5Anodized.
6Chromatized
Control & Pneumatic
Modules
For material specification of
the Pneumatic Modules see
page 2
Corrosion protection
The applied paint system
has passed a 1000 hour salt
spray test as detailed by
ASTM B117. For a detailed
description of the Corrosion
protection system see data
sheet BQ1.606.05.
Repair kit
Parts marked with an * are
included in the repair kit
Product data sheet
Sheet No.: BQ1.606.01 - Rev: 1, Page 2 of 2
Date:
January 2017
Q-Series
Bettis Q-Series actuator
Parts and materials - Modules
Base Materials
Bodies:Aluminium
Finish:
2 Component with an epoxy
primer and polyurethane enamel
top coating.
Pneumatic cartridge: Aluminium
Valve seats
NBR
Fasteners
Stainless Steel
3
External parts
1 Plug
2 Exhaust
NPT:
Base :
Cover:
Steel, Nickel plated
Nylon PA6
Zinc Nickel plated and transparent
passivated
Option: Plastic silencer (nylon)
3 Speed Control:
Stainless Steel (AISI 303)
4 Manual Control:
Red anodized aluminum
5 Nut Covers:
Nylon PA6
1
2
4
Parts and materials - Modules
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.606.0 - Rev: 0
Date:
May 2014
Q-Series
Bettis Q-Series valve actuator
Failure modes
Valve rotation
Closed
Valves are normally manufactured so that:
1 The valve is closed
2 The valve is open
: after a clock wise rotation*
: after a counter clock wise
rotation*
*) = views from above
Open
Position after a failure
The position of the actuator after a failure depends on:
1 Principles of operation Spring Return or Double Acting
2 Actuator assembly code
See BQ1.606.03 for Double Acting
See BQ1.606.04 for Spring Return
3 Kind of failure See table.
Principle
of
operation:
Assembly code :
CW
Double acting
actuator
CC
CW
Single acting
actuator
(Spring Return)
CC
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Kind
of
failure :
Pressure
not defined
Signal
Closed
Position :
Supply voltage
Closed
Pressure
not defined
Signal
Open
Supply voltage
Open
Pressure
Closed
Signal
Closed
Supply voltage
Closed
Pressure
Open
Signal
Open
Supply voltage
Open
Product data sheet
Sheet No.: BQ1.606.03 - Rev: 0
Date:
May 2014
Q-Series
B
B
Actuator assembly codes
A
A
Double acting assembly codes
2
Standard assembly code:
1
CW
(= Clock Wise Rotation)
Visual indicator mounted:
2
Optional assembly code:
A
Visual indicator mounted:
(= for In line position indication
2
A
A
B
2
2
2
1
I
B
Position
indicator
B
CC
(= Counter Clock Wise Rotation)
Pinion
B
2
1
I
(= for In line position indication
A
2
1
2
2
B
1
1
2
2
B
A
A
Pistons
2
Optional assembly code:
CW
(= Clock Wise Rotation)
A
Visual indicator mounted:
(= for CrossBline position indication
B
C
Optional assembly code:
Visual indicator mounted:
B (= for Cross line position indication
C
2
2
1
1
A
A
B
B
1
2
A
1
-
-
2
1
2
Central air chamber (1) pressurized
End cap air chambers (2) pressurized
All views are from above. Pistons are shown in inner position
2
2
2
2
A= Pilot valve operated in Control Module B= Pilot valve
not operated in Control Module B
2
CC
2
2
1
(= Counter Clock Wise Rotation)
A
2
A
2
2
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.606.04 - Rev: 0
Date:
May 2014
Q-Series
B
B
A
A
Actuator assembly codes
Single acting (Spring Return) assembly codes
2
Standard assembly code:
2
CW
1
(= Clock Wise Rotation / Spring to Close)
Visual indicator mounted:
Optional assembly code:
2
I
(= for In line position indication
Visual indicator mounted:
(= for In line position indication
Pinion
B
B
2
CC
I
B
Position
indicator
A
A
2Spring to
1
(= Counter Clock Wise Rotation/
Open)
A
A
B
2
2
2
B
2
1
1
2
A
B
21
1
2
1
Optional assembly code:
(= Clock Wise Rotation / Spring to Close)
A
Visual indicator mounted:
(= for Cross line position indication
B
CW
C
A
B
(= Counter Clock Wise Rotation/ Spring to
Open)
Visual indicator mounted:
(= for Cross line position indication
2
2
2
2
2
1
1
A
B
B
2
2
2
1
2
Central air chamber (1) pressurized
Spring Stroke (2)
All views are from above. Pistons are shown in inner position
2
1
CC
A
1
-
-
CC
A
2
A= Pilot valve operated in Control Module B= Pilot valve
not operated in Control Module B
2
Optional assembly code:
B
2
A
2
Pistons
A
2
2
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.606.07 - Rev: 1
Date:
March 2017
Q-Series
Bettis Q-Series Valve Actuator
Corrosion Protection
Description
Technical data base actuator
The corrosion protection system of Bettis Q-Series actuators
consist of the following treatments or materials:
Finish:
Thickness:
Salt spray test:
Color: Materials:
Housing: Pistons: Pinion: Fasteners: Type plate: 1Pretreatment
The actuator housings are anodized inside and outside, to
give them a durable and superb protection against wear and
corrosion.
2De-greasing
All aluminum parts are de-greased before the coating is
applied by washing with an alkaline solution to assure the best
bonding between the aluminum surface and the coating.
3Finish
3.1Actuator
- Polyurethane powder coating for exterior use.
- The powder coating is applied cold using automatic
electrostatic spray equipment and is cured for about 10
minutes at minimum 200°C (392°F) offering excellent light
and weather resistance.
3.2Module
- Polyurethane coating for exterior use.
- The coating offers excellent light and weather resistance.
- Good chemical resistance against most bases, acids,
solvents, alkalis and oils at normal temperatures.
- Excellent exterior mechanical durability.
4 High grade & hard anodized aluminum pinion.
Actuators with high grade & hard anodized aluminum pinions,
passed a 1000 hours salt spray test.
Polyurethane powder coating
80 to 160 micrometer (3.1 to 6.2 mils).
1000 hours (ASTM B117)
Orange
Anodized aluminium alloy
Chromatized
High grade aluminum alloy, hard anodized
Stainless steel or coated alloy steel.
Stainless steel
Technical data Control Module
Finish: 2 Component with an epoxy primer and
polyurethane enamel top coating.
Thickness: 80 to 160 micrometer (3.1 to 6.2 mils).
Salt spray test: 1000 hours (ASTM B117)
Color: Orange
Materials:
Housing:
Fasteners:
Type plate: Anodized aluminium alloy
Stainless steel or coated alloy steel.
Vinyl
Base
actuator
Module
5 Stainless steel or coated steel parts.
External parts are stainless steel or coated alloy steel.
6 Corrosion protected springs on Spring Return actuators
All the springs of spring return actuator are Deltatone® or
epoxy (black) coated to prevent the corrosion of the springs
and assure a long cycle life.
Stainless steel
Fasteners
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.607.01 - Rev: 0, Page 1 of 7
March 2017
Date:
Q-Series
Bettis Q-Series Valve Actuator
How to Order
Bettis Q-Series and its accessories can be ordered in
different ways. Please follow below instruction to define
the confirugation code for ordering Bettis Q-Series Valve
Operating Systems.
1
Bettis Q-Series with Integrated Controls
2
To order Bettis Q-Series, two main parts have to be defined or
configured:
1 The base actuator.
2 The control module
Procedure:
1 Select the required Actuator Action
• Spring Return (a.k.a. Single acting)
• Double acting
• Double acting, Fail in Last Position
2 Determine the Actuator Size
• Use the actuator torque data sheets or approved sizing program.
3 Select additional actuator configurations/options
See page 2 of 7
Note: To make the actuator suitable for Control
modules select "XX" in the Pneumatic interface
segment.
4 Select the Required Control Module
• Select the required Control Module functionality based on the table below:
Module Description
Sample model string:
Actuator:QS0350.U04STKCW.XX270DI
Control Module: QC41MWPMSK1.0350INS0IP10
See page:
QC41
Conventional Module + 24 VDC Pilot valve
3 of 7
QC42
Conventional Module + 110 VAC Pilot valve
3 of 7
QC43
Conventional Module + 230 VAC Pilot valve
3 of 7
QC40
ASI Module (Metric)
4 of 7
QC40
ASI Module (Imperial)
5 of 7
QC54
Foundation Fieldbus Module (Metric)
6 of 7
QC54
Foundation Fieldbus Module (Imperial)
7 of 7
5 Select additional configurations/options
• Be sure to include the "Installed" (I)option to mount the Control Module to the Bettis Q-Series Actuator.
• Be sure to include the IPT device with the control module. This IPT device should be the same size as the actuator size, to which the module is mounted.
You have now selected a complete Bettis Q-Series Valve
Operating Systems with Integrated Controls.
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.607.01 - Rev: 0, Page 2 of 7
March 2017
Date:
Q-Series
Model String Configuration
Base Actuator
QS 0350 ● U 04 ST K CW ● XX S27 0 D I
Actuator Type
Actuator Size
Connections
Spring Set
Temperature Range
Future Expansions
Assembly Code
Actuator Type
QD Double Acting
QS Spring Return
Actuator Size
0040 Size 40
0350 Size 350
0065 Size 65
0600 Size 600
0100 Size 100
0950 Size 950
0150 Size 150
1600 Size 1600
0200 Size 200
Connections
M
Metric Actuator (ISO 5211)
U
Imperial actuator (ISO 5211 / UNC)
Spring Set (note5)
00
Double Acting
01
SpringSet 01
04
SpringSet 04
02
SpringSet 02
05
SpringSet 05
03
SpringSet 03
06
SpringSet 06
Temperature Range
ST
Standard Temp. Range -20° to +80°C (-4° to 176°F)
Future Expansion
K
Bettis Orange
Assembly Code (note 1)
CW Clockwise rotation (Spring to Close)
CC Counter-Clockwise rotation (Spring to Open)
Valve Mounting
Visual Indication
Valve Flange
Insert Size
Pneumatic Interface
Pneumatic Interface
XX Actuator suitable for Control modules
Insert Size Code (note 2)
S10 Square 10 mm (0.39")
S22 Square 22 mm (0.87")
S12 Square 12 mm (0.47")
S24 Square 24 mm (0.94")
S14 Square 14 mm (0.55")
S27 Square 27 mm (1.06")
S16 Square 16 mm (0.63")
S36 Square 36 mm (1.42")
S17 Square 17 mm (0.67")
S46 Square 46 mm (1.81")
S19 Square 19 mm (0.75")
Valve Flange Code
00
ISO 5211 (No Centerplate)
05
DIN3337 F05 (Centerplate / insert @ 45°)
07
DIN3337 F07 (Centerplate / insert @ 45°)
10
DIN3337 F10 (Centerplate / insert @ 45°)
12
DIN3337 F12 (Centerplate / insert @ 45°)
14
DIN3337 F14 (Centerplate / insert @ 45°)
16
DIN3337 F16 (Centerplate / insert @ 45°)
Visual Indication Code
D
Standard Indicator
X
No Indicator
Valve Mounting Code
I
In line with the pipe line
C
Cross line with the pipe line
Notes:
1
2
Assembly code CW is "Spring-to-Close", in combination with integrated modules.
Assembly code CC is "Spring-to-Open", in combination with integrated modules.
Failure mode of FieldQ with NAMUR plate depends on what solenoid is used.
See Insert Supplement for Additional Insert Options.
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.607.01 - Rev: 0, Page 3 of 7
March 2017
Date:
Q-Series
Model String Configuration
Conventional Wired Control Module
QC41 ● U WP M S K 1 ● 0040 I NS 0 IP 0 0
Control module
Conduit connections
Protection method
Control module options
Action
Future Expansions
Language
Control module
QC41 Control module with 24 VDC pilot valve
QC42 Control module with 115 VAC pilot valve
QC43 Control module with 230 VAC pilot valve
Connections
M
Metric: Conduit: 2x M20x1.5 - Pneumatic: 1/4" BSP
Imperial - Conduit: Top: 3/4"NPT; Bottom 1/2"NPT
U
Pneumatic entry 1/4"NPTT
Protection method
WP Weather Proof IP66/NEMA4X
P5
Flame- or Explosion proof approval (note 1)
Control module options (position feedback)
M
Mechanical switch
G
Mechanical switch (Gold Plated)
O
3-wire prox. switch PNP
C
3-wire prox. switch NPN
N
2-wire prox. switch (NAMUR)
H
2-wire prox. switch (20-140 VAC/10-140 VDC)
Action
S
Single acting (Spring Return)
D
Double acting
F
Double acting Fail "In Last Position"
Future Expansions Code
K
Standard Orange
Language Code
1
English
Bottom electrical entry
Top electrical entry
Pneumatic exhaust
Manual Control
Speed control
Mounting Options
IPT Device size actuator
IPT Device size for actuator:
0040 Q40 actuator
0065 Q65 actuator
0100 Q100 actuator
0150 Q150 actuator
0200 Q200 actuator
0350 Q350 actuator
0600 Q600 actuator
0950 Q950 actuator
1600 Q1600 actuator
0000 No IPT probe
Mounting Options
U
Uninstalled
I
Installed/Tested to actuator
Speed control
NS No Speed Control
N1 Spring Return (1x throttle)
N2 Double acting (2x throttle)
Manual Control
0
No Manual Control
1
1x "Push&Lock", anodized aluminum
2
2x "Push&Lock", anodized aluminum
3
1x "Push&Lock", Stainless Steel
4
2x "Push&Lock", Stainless Steel
Pneumatic exhaust
IP
IP65/NEMA4 rated exhaust
IN
Non metalic exhaust / Check valve
Top conduit (Glands & Plugs, note 3)
0
Transport plug
1
Metal blind plug
Bottom conduit (Glands & Plugs, note 3)
0
Transport plug
1
Metal blind plug
Notes:
1QC4x "P5" Modules with Metric conduit connections come with ATEX and IECEx approvals and allow for use in Zone 1, 2, 21, 22.
QC4x "P5" Modules with NPT conduit connections come with ATEX, IECEx, FM and CSA approvals allow for use in Class 1 Division 1
classified hazardous areas.
2 2x Manual Control are only required incase of Double acting with Fail in Last Position function.
3 Glands & Plugs options are a responsibility of the installer. Appropriate instructions can be found in the Installation Guide DOC.IG.QC41.1.
4 No separate pneumatic module required.
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.607.01 - Rev: 0, Page 4 of 7
March 2017
Date:
Q-Series
Metric Model String Configuration
QC40 with ASI Digital Bus Communication
QC40 ● M WP G S K 1 ● 0040 I NS 0 IP 0 0
Control module
Conduit connections
Protection method
Control module options
Action
Future Expansions
Language
Control module
QC40 Control module with AS-I communication
Connections
M
Metric: Conduit: 2x M20x1.5 - Pneumatic: 1/4" BSP
Protection method
WP Weatherproof IP66 / NEMA4X
P4
Non-Incendive / Non Arcing
Control module options (position feedback)
G
Mechanical switch (Gold Plated)
N
2-wire prox. switch (NAMUR)
Action
S
Single acting (Spring Return)
D
Double acting
F
Double acting Fail "In Last Position"
Future Expansions Code
K
Standard Orange
Language Code
1
English
IPT Device size for actuator:
0040 Q40 actuator
0065 Q65 actuator
0100 Q100 actuator
0150 Q150 actuator
0200 Q200 actuator
0350 Q350 actuator
0600 Q600 actuator
0950 Q950 actuator
1600 Q1600 actuator
0000 No IPT probe
Bottom electrical entry
Top electrical entry
Pneumatic exhaust
Manual Control
Speed control
Mounting Options
IPT Device size actuator
Mounting Options
U
Uninstalled
I
Installed/Tested to actuator
Speed control
NS No Speed Control
N1 Spring Return (1x throttle)
N2 Double acting (2x throttle)
Manual Control
0
No Manual Control
1
1x "Push&Lock", anodized aluminum
2
2x "Push&Lock", anodized aluminum
3
1x "Push&Lock", Stainless Steel
4
2x "Push&Lock", Stainless Steel
Pneumatic exhaust
IP
IP65/NEMA4 rated exhaust
IN
Non metalic exhaust / Check valve
Top conduit (Glands & Plugs, note 3)
0
Transport plug
1
Metal blind plug
4
Eurofast (M12)
5
Minifast (7/8”)
Bottom conduit (Glands & Plugs, note 3)
0
Transport plug
1
Metal blind plug
4
Eurofast (M12)
5
Minifast (7/8”)
Notes:
1.
2.
3.
4.
5.
Pending certification, only Weather Proof (WP) and ATEX/IECEx versions available.
2x Manual Control are only required incase of Double acting with Fail in Last Position function.
Glands & Plugs options are a responsibility of the installer. Appropriate instructions can be found in the Installation Guide DOC.IG.BQC40.1.
The Quick Connectors, as listed, are excluded from areas with a potential explosion hazard caused by gasses, dust or fibers. The default
location for the Quick Connector is the bottom conduit.
2x quick connectors (top and bottom conduit) for daisy chaining 2 units is not recommended.
For applications below -20°C (-4°F), the base actuator must be fitted with Low Temperature seals.
No separate pneumatic module required.
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.607.01 - Rev: 0, Page 5 of 7
March 2017
Date:
Q-Series
Imperial Model String Configuration
QC40 with ASI Digital Bus Communication
QC40 ● U WP G S K 1 ● 0040 I NS 0 IP 0 1
Control module
Conduit connections
Protection method
Control module options
Action
Future Expansions
Language
Control module
QC40 Control module with AS-I communication
Connections
Imperial - Conduit: Top: 3/4""NPT; Bottom 1/2""NPT
U
Pneumatic entry 1/4"NPT
Protection method
WP Weatherproof IP66 / NEMA4X
P4
Non-Incendive / Non Arcing
Control module options (position feedback)
G
Mechanical switch (Gold Plated)
N
2-wire prox. switch (NAMUR)
Action
S
Single acting (Spring Return)
D
Double acting
F
Double acting Fail "In Last Position"
Future Expansions Code
K
Standard Orange
Language Code
1
English
IPT Device size for actuator:
0040 Q40 actuator
0065 Q65 actuator
0100 Q100 actuator
0150 Q150 actuator
0200 Q200 actuator
0350 Q350 actuator
0600 Q600 actuator
0950 Q950 actuator
1600 Q1600 actuator
0000 No IPT probe
Bottom electrical entry
Top electrical entry
Pneumatic exhaust
Manual Control
Speed control
Mounting Options
IPT Device size actuator
Mounting Options
U
Uninstalled
I
Installed/Tested to actuator
Speed control
NS No Speed Control
N1 Spring Return (1x throttle)
N2 Double acting (2x throttle)
Manual Control
0
No Manual Control
1
1x "Push&Lock", anodized aluminum
2
2x "Push&Lock", anodized aluminum
3
1x "Push&Lock", Stainless Steel
4
2x "Push&Lock", Stainless Steel
Pneumatic exhaust
IP
IP65/NEMA4 rated exhaust
IN
Non metalic exhaust / Check valve
Top conduit (Glands & Plugs, note 3)
0
Transport plug
1
Metal blind plug
Bottom conduit (Glands & Plugs, note 3)
1
Metal blind plug
4
Eurofast (M12)
5
Minifast (7/8”)
Notes:
1. Pending certification, only Weather Proof (WP) and ATEX/IECEx versions available.
2. 2x Manual Control are only required incase of Double acting with Fail in Last Position function.
3. Glands & Plugs options are a responsibility of the installer. Appropriate instructions can be found in the Installation Guide DOC.IG.BQC40.1.
The Quick Connectors, as listed, are excluded from areas with a potential explosion hazard caused by gasses, dust or fibers.
For imperial units only the bottom entry (1/2"NPT) is available with quick connectors.
2x quick connectors (top and bottom entry) for daisy chaining 2 units, is not recommended.
4. For applications below -20°C (-4°F), the base actuator must be fitted with Low Temperature seals.
5. No separate pneumatic module required.
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.607.01 - Rev: 0, Page 6 of 7
March 2017
Date:
Q-Series
Metric Model String Configuration
QC54 with Foundation Fieldbus™ Bus Communication
QC54 ● M WP S S K 1 ● 0040 I NS 0 IP 0 0
Control module
Conduit connections
Protection method
Control module options
Action
Future Expansions
Language
Control module
QC54 Control module with Foundation Fieldbus communication
Connections
M
Metric: Conduit: 2x M20x1.5 - Pneumatic: 1/4" BSP
Protection method
WP Weatherproof IP66 / NEMA4X
P4
Non-Incendive / Non Arcing Ex nA
P1
Intrinsically Safe / Ex i
Control module options
S
Standard configuration
Action
S
Single acting (Spring Return)
D
Double acting
F
Double acting Fail "In Last Position"
Future Expansions Code
K
Standard Orange
Language Code
1
English
IPT Device size for actuator:
0040 Q40 actuator
0065 Q65 actuator
0100 Q100 actuator
0150 Q150 actuator
0200 Q200 actuator
0350 Q350 actuator
0600 Q600 actuator
0950 Q950 actuator
1600 Q1600 actuator
0000 No IPT probe
Bottom electrical entry
Top electrical entry
Pneumatic exhaust
Manual Control
Speed control
Mounting Options
IPT Device size actuator
Mounting Options
U
Uninstalled
I
Installed/Tested to actuator
Speed control
NS No Speed Control
N1 Spring Return (1x throttle)
N2 Double acting (2x throttle)
Manual Control
0
No Manual Control
1
1x "Push&Lock", anodized aluminum
2
2x "Push&Lock", anodized aluminum
3
1x "Push&Lock", Stainless Steel
4
2x "Push&Lock", Stainless Steel
Pneumatic exhaust
IP
IP65/NEMA4 rated exhaust
IN
Non metalic exhaust / Check valve
Top conduit (Glands & Plugs, note 3)
0
Transport plug
1
Metal blind plug
4
Eurofast (M12)
5
Minifast (7/8”)
Bottom conduit (Glands & Plugs, note 3)
0
Transport plug
1
Metal blind plug
4
Eurofast (M12)
5
Minifast (7/8”)
Notes:
1.
2.
3.
4.
5.
Pending certification, only Weather Proof (WP) versions available.
2x Manual Control are only required incase of Double acting with Fail in Last Position function.
Glands & Plugs options are a responsibility of the installer. Appropriate instructions can be found in the Installation Guide DOC.IG.QC54.1.
The Quick Connectors, as listed, are excluded from areas with a potential explosion hazard caused by gasses, dust or fibers. The default
location for the Quick Connector is the bottom conduit.
2x quick connectors (top and bottom conduit) for daisy chaining 2 units is not recommended.
For applications below -20°C (-4°F), the base actuator must be fitted with Low Temperature seals.
No separate pneumatic module required.
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.607.01 - Rev: 0, Page 7 of 7
March 2017
Date:
Q-Series
Imperial Model String Configuration
QC54 with Foundation Fieldbus™ bus communication
QC54 ● U WP S S K 1 ● 0040 I NS 0 IP 0 1
Control module
Conduit connections
Protection method
Control module options
Action
Future Expansions
Language
Control module
QC54 Control module with Foundation Fieldbus communication
Connections
Imperial - Conduit: Top: 3/4""NPT; Bottom 1/2""NPT
U
Pneumatic entry 1/4"NPT
Protection method
WP Weatherproof IP66 / NEMA4X
P4
Non-Incendive / Non Arcing Ex nA
P1
Intrinsically Safe / Ex i
Control module options
S
Standard configuration
Action
S
Single acting (Spring Return)
D
Double acting
F
Double acting Fail "In Last Position"
Future Expansions Code
K
Standard Orange
Language Code
1
English
IPT Device size for actuator:
0040 Q40 actuator
0065 Q65 actuator
0100 Q100 actuator
0150 Q150 actuator
0200 Q200 actuator
0350 Q350 actuator
0600 Q600 actuator
0950 Q950 actuator
1600 Q1600 actuator
0000 No IPT probe
Bottom electrical entry
Top electrical entry
Pneumatic exhaust
Manual Control
Speed control
Mounting Options
IPT Device size actuator
Mounting Options
U
Uninstalled
I
Installed/Tested to actuator
Speed control
NS No Speed Control
N1 Spring Return (1x throttle)
N2 Double acting (2x throttle)
Manual Control
0
No Manual Control
1
1x "Push&Lock", anodized aluminum
2
2x "Push&Lock", anodized aluminum
3
1x "Push&Lock", Stainless Steel
4
2x "Push&Lock", Stainless Steel
Pneumatic exhaust
IP
IP65/NEMA4 rated exhaust
IN
Non metalic exhaust / Check valve
Top conduit (Glands & Plugs, note 3)
0
Transport plug
1
Metal blind plug
Bottom conduit (Glands & Plugs, note 3)
1
Metal blind plug
4
Eurofast (M12)
5
Minifast (7/8”)
Notes:
1.
2.
3.
4.
5.
Pending certification, only Weather Proof (WP) versions available.
2x Manual Control are only required incase of Double acting with Fail in Last Position function.
Glands & Plugs options are a responsibility of the installer. Appropriate instructions can be found in the Installation Guide DOC.IG.QC54.1.
The Quick Connectors, as listed, are excluded from areas with a potential explosion hazard caused by gasses, dust or fibers. The default
location for the Quick Connector is the bottom conduit.
2x quick connectors (top and bottom conduit) for daisy chaining 2 units is not recommended.
For applications below -20°C (-4°F), the base actuator must be fitted with Low Temperature seals.
No separate pneumatic module required.
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
World Area Configuration Centers (WACC) offer sales support,
service, inventory and commissioning to our global customers.
Choose the WACC or sales office nearest you:
NORTH & SOUTH AMERICA
MIDDLE EAST & AFRICA
19200 Northwest Freeway
Houston, TX 77065
T +1 281 477 4100
F +1 281 477 2809
P. O. Box 17033
Dubai
United Arab Emirates
T +971 4 811 8100
F +971 4 886 5465
Av. Hollingsworth,
325, Iporanga Sorocaba,
SP 18087-105
Brazil
T +55 15 3238 3788
F +55 15 3228 3300
ASIA PACIFIC
No. 9 Gul Road
#01-02 Singapore 629361
T +65 6501 4600
F +65 6268 0028
No.1 Lai Yuan Road
Wuqing Development Area
Tianjin 301700
P.R.China
T +86 22 8212 3300
F +86 22 8212 3308
P. O. Box 10305
Jubail 31961
Saudi Arabia
T +966 3 340 8650
F +966 3 340 8790
24 Angus Crescent
Longmeadow Business Estate
East P.O. Box 6908; Greenstone;
1616 Modderfontein, Extension 5
South Africa
T +27 11 451 3700
F +27 11 451 3800
EUROPE
Berenyi u. 72-100
Videoton Industry Park
Building #230
Székesfehérvár 8000
Hungary
T +36 22 53 09 50
F +36 22 54 37 00
For complete list of sales and manufacturing sites, please visit
www.emerson.com/actuationtechnologieslocations
Or contact us at [email protected]
www.emerson.com/bettis
©2017 Emerson. All Rights Reserved.
We reserve the right to modify or improve the designs or specifications
of the products mentioned in this manual at any time without notice.
Emerson does not assume responsibility for the selection, use or
maintenance of any product. Responsibility for proper selection, use
and maintenance of any Emerson product remains solely with the
purchaser.
www.emerson.com/bettis
Copyright © Emerson. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.emerson.com/bettis or from your nearest Actuation Technologies Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +36 22 53 09 50 (fax +36 22 54 37 00) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement