SHIMANO E-Tube Project Operating Manual
Below you will find brief information for E-Tube Project.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Etube Project
Operating Manual
CONTENTS
INTRODUCTION ....................................................................................................................................3
NAMES OF PARTS.................................................................................................................................4
ABOUT ETUBE PROJECT ....................................................................................................................5
APPLICATION SPECIFICATIONS ...........................................................................................................6
INSTALLING THE SMPCE1 DRIVER .....................................................................................................7
CONNECTING THE SMPCE1................................................................................................................8
For normal connections .......................................................................................................................8
If there are no spare terminals .............................................................................................................9
Connecting a standalone unit............................................................................................................10
LAUNCHING AND CLOSING THE APPLICATION .................................................................................10
Launching the application ..................................................................................................................10
Closing the application....................................................................................................................... 11
ABOUT THE APPLICATION OPERATION WINDOWS ...........................................................................12
Main window .....................................................................................................................................12
Menu bar...........................................................................................................................................13
Operation wizard window...................................................................................................................17
Bicycle window..................................................................................................................................18
Log window.......................................................................................................................................20
CUSTOMIZE ........................................................................................................................................21
Shifting switch function settings..........................................................................................................22
Rear derailleur adjustment settings ....................................................................................................23
PROBLEM DIAGNOSIS........................................................................................................................25
Flow of problem diagnosis .................................................................................................................26
UPDATING FIRMWARE........................................................................................................................32
If an error occurs while updating firmware ..........................................................................................34
Upper limit for number of firmware updates ........................................................................................35
OVERWRITING INITIAL FIRMWARE ....................................................................................................36
ABOUT THIS DOCUMENT ...................................................................................................................38
REGISTERED TRADEMARKS AND TRADEMARKS .............................................................................38
2 / 38
INTRODUCTION
INTRODUCTION
This operating manual contains instructions for operating Etube Project.
In order to fully utilize the functions of Etube Project, please read this manual thoroughly before use.
Note: l Never connect or disconnect the battery and the units after you have clicked [Next] in the unit connection standby window. If this is not observed, it may damage the SMPCE1 or the other units. l Never attempt to change the contents of the firmware files or the filenames. If you do this, it will not be possible to update the firmware correctly, and problems may occur with the units after carrying out firmware updates. n NOTE: l When connecting the SMPCE1 to the PC, connect it directly to the USB port of the PC, without using an intermediate device such as a USB hub. l Make sure that the PC does not switch into standby while you are carrying out operations such as updating the firmware.
If the PC switches to standby, ETube Project processing will be interrupted and the screen display will return to the main window. l When overwriting the initial firmware, connect the units to the SMPCE1 as standalone units. l After unit recognition has occurred while the battery is connected and the screen display has returned to the main window, momentarily disconnect the battery and then reconnect it. l Rotate the crank arms while carrying out operations which are related to adjustment and gear shifting. l Use the TLEW02 special tool to install and remove the electric wires.
3 / 38
NAMES OF PARTS
NAMES OF PARTS
SMEW67AE
SWR600
ST6770L
ST6770R
RD6770 FD6770 SMBMR1
4 / 38
ABOUT ETUBE PROJECT
ABOUT E-TUBE PROJECT
Etube Project is an application for use in the maintenance and problem diagnosis of the various units.
The main functions are as follows.
Functions Details
Customize This function is used to customize the gear shifting system. n Shifting switch function settings
This function changes the functions of the ST6770 and SWR600 shifting switches. n Rear derailleur adjustment settings
This function adjusts the gear shifting by the rear derailleur.
Problem diagnosis
Update firmware
Overwrite initial firmware
When a single unit or multiple units are connected, this function checks their operation and identifies any units which have a problem.
However, this does not mean that all such problems can be discovered. In addition, the function does not fix any problems which are discovered.
This function is used to update the firmware for each unit to the latest versions.
(The firmware is downloaded via the Internet.)
If the firmware which has been written to a unit becomes corrupted for reasons such as the USB cable or an electric wire becoming accidentally disconnected while updating of the firmware is in progress, the unit will not operate correctly.
This function can be used to overwrite the firmware for such units in order to restore normal operation.
5 / 38
APPLICATION SPECIFICATIONS
APPLICATION SPECIFICATIONS
The following operating environment is required in order to use Etube Project.
Item Details
Operating system
Required components
Other hardware
Windows XP 32bit/64bit (SP3 or later)
Windows Vista 32bit/64bit
Windows 7 32bit/64bit
. NET Framework 3.5
1
1
USB 1.1/2.0
Active Internet connection
Display resolution: XGA (1024 x 768 dots) or higher
Compatible languages * English
* French
* German
* Dutch
* Spanish
* Italian
* Chinese
* Japanese
*
The language can be changed by means of “Application settings” as described on page 15.
1 Etube Project will not operate correctly under .NET Framework 3.0. or .NET Framework 4.0.
6 / 38
INSTALLING THE SMPCE1 DRIVER
INSTALLING THE SM-PCE1 DRIVER
In order to use the SMPCE1 while it is connected to a PC, you need to install the driver for the SMPCE1.
After installation of Etube Project is complete, connect the SMPCE1 and the PC using the USB cable. The installation wizard window will be displayed automatically.
Select “Install software automatically” and then click [Next].
*
Depending on the environment of the PC you are using, you may be prompted to connect to
Windows Update to search for software. If this happens, select “No, not this time” and then click
[Next].
Screenshots in English from Windows XP are used as examples here.
When the message “Completing the Found New Hardware Wizard” is displayed, the setup for using the
SMPCE1 is complete.
*
Depending on the environment of the PC you are using, it may be necessary to restart the PC.
7 / 38
CONNECTING THE SMPCE1
CONNECTING THE SM-PCE1
When connecting the SMPCE1 to the PC, connect it directly to the USB port of the PC, without using an intermediate device such as a USB hub.
For normal connections
Connect to any spare terminal which is available.
8 / 38
CONNECTING THE SMPCE1
If there are no spare terminals
Disconnect one of the cables from the SMJC40, and connect the SMPCE1 in its place.
*
For the electric wire builtin type (SMJC41), remove the SWR600 from the desired ST6770, and then connect the SMPCE1 to the spare terminal. The SWR600 which was disconnected must be reconnected elsewhere.
9 / 38
Connecting a stand-alone unit
LAUNCHING AND CLOSING THE APPLICATION
LAUNCHING AND CLOSING THE APPLICATION
Launching the application
After installing Etube Project, doubleclick the Etube Project shortcut icon on the desktop which was created during the installation procedure.
If the PC is connected to the Internet, checks for updates to the latest firmware versions and application updates will be carried out when the application is launched.
10 / 38
LAUNCHING AND CLOSING THE APPLICATION
User verification
When you launch Etube Project for the first time after it has been installed, you will be prompted to enter a user ID and a password.
Enter the user ID and the password which are given in the Service Instructions for the SMPCE1.
Launching requirements
In order to use Etube Project, the SMPCE1 must be connected to the PC.
When the “SMPCE1 connection request” dialog box is displayed, connect the SMPCE1 to the PC using the USB cable.
Closing the application
Select “Exit” from the “File” menu on the menu bar. Alternatively, click the close button in the topright corner of the application window.
When the “Exit confirmation” dialog box is displayed, click [OK] to close Etube Project.
*
Etube Project cannot be closed while firmware updating is still in progress.
11 / 38
ABOUT THE APPLICATION OPERATION WINDOWS
ABOUT THE APPLICATION OPERATION WINDOWS
Main window
When Etube Project is launched, the main window is displayed. The main window consists of the following four elements.
1. Menu bar
2. Operation wizard window
3. Bicycle window
4. Log window
2
2
1
2 3
4
(Main window)
2 Not displayed immediately after Etube Project is launched.
12 / 38
ABOUT THE APPLICATION OPERATION WINDOWS
Menu bar
This contains the various operations that are carried out by the application.
File
n Save operation log
This saves the log data in the log window.
Specify the saving destination and the filename in the ”Save file” dialog box, and then click the [Save] button. n Exit
This closes Etube Project.
Functions
n Download firmware
This function is used for downloading the latest firmware.
When this function is selected, a list of the latest firmware is retrieved via the Internet, and the “Select firmware” dialog box is displayed.
Follow the instructions appearing in the window to download the latest firmware.
*
Connect to the Internet when downloading the firmware.
If you are using a PC without an active Internet connection, a warning message will be displayed and the firmware download will end.
*
If there is no firmware available for downloading, a message telling you this will be displayed.
The firmware files which have been downloaded will be stored in the following folders.
These folders are created automatically when the application is installed.
Version
Windows XP
Save destination
My Documents¥Etube Project¥FW
Windows Vista
Windows 7
Documents¥Etube Project¥FW
Documents¥Etube Project¥FW
*
Never attempt to change the contents of the firmware files or the filenames. If you do this, it will not be possible to update the firmware correctly, and problems may occur with the units after carrying out firmware updates.
13 / 38
ABOUT THE APPLICATION OPERATION WINDOWS
View
n View Log Window
This function selects whether the log window is displayed or not displayed.
When the log window is set to be displayed, the log window will be displayed at the bottom of the main window.
You can also switch the log window between being displayed and not displayed by clicking on the log window button in the lowerright corner of the window.
(Log window button)
14 / 38
ABOUT THE APPLICATION OPERATION WINDOWS
Establish
n Application settings
This function is used to set the language to be used when using Etube Project and to set whether the “Exit confirmation” dialog box is displayed or not.
Change the various settings in the “Application settings” dialog box.
Click [OK] to exit application settings.
The setting items are as follows.
Setting item Description
Language Sets the language to be used when using Etube Project.
You can select from the following languages.
“Exit confirmation” dialog box display
* English
* French
* German
* Dutch
* Spanish
* Italian
* Chinese
* Japanese
This sets whether the “Exit confirmation” dialog box is displayed or not displayed when Etube Project is closed.
When you change the language, the “Relaunch confirmation” dialog box will be displayed.
To apply the changed setting, click [Yes] and then relaunch Etube Project.
If you click [No], the language will be changed the next time you launch Etube Project.
15 / 38
ABOUT THE APPLICATION OPERATION WINDOWS
Help
n Manual Help
This displays the Etube Project manual (this document). n Check Application Version
This function checks whether an updated version of Etube Project is available for downloading.
*
The PC needs to be connected to the Internet for this check to be carried out.
If there is a new version available, a notification balloon will be displayed in the Windows task tray.
Click on the balloon to move to the download site and follow the prompts to install the update. n About Etube Project...
This displays the version of Etube Project which is currently being used and the operating environment in the “About Etube Project...” dialog box.
16 / 38
ABOUT THE APPLICATION OPERATION WINDOWS
Operation wizard window
This contains the operations for carrying out unit maintenance and problem diagnosis.
The main functions are as follows.
Functions Details
Customize This function is used to customize the gear shifting system. n Shifting switch function settings
This function changes the functions of the ST6770 and SWR600 shifting switches. n Rear derailleur adjustment settings
This function adjusts the gear shifting by the rear derailleur.
Problem diagnosis
Update firmware
When a single unit or multiple units are connected, this function checks their operation and identifies any units which have a problem.
However, this does not mean that all such problems can be discovered. In addition, the function does not fix any problems which are discovered.
This function is used to update the firmware for each unit to the latest versions.
(The firmware is downloaded via the Internet.)
Overwrite initial firmware
If the firmware which has been written to a unit becomes corrupted for reasons such as the USB cable or an electric wire becoming accidentally disconnected while updating of the firmware is in progress, the unit will not operate correctly.
This function can be used to overwrite the firmware for such units in order to restore normal operation.
Etube Project will check that there is sufficient charge in the SMPCE1 before using the various functions in the operation wizard window. (The SMPCE1 has a builtin capacitor which stores electrical power.)
If there is insufficient charge in the SMPCE1, the “SMPCE1 Charging” dialog box will be displayed, and charging will start automatically. The LED on the SMPCE1 unit will flash during charging.
3
3
3 Charging will be complete after about 30 seconds.
17 / 38
ABOUT THE APPLICATION OPERATION WINDOWS
If the battery is disconnected and then immediately reconnected, Etube Project may not immediately recognize connected units when it carries out unit recognition, but this is not the sign of a problem.
Wait for a brief period and then carry out unit recognition once again.
Bicycle window
This window shows the unit status and data while the application is being used.
Unit status
This displays the statuses of connected units graphically.
The unit status displays are as follows.
View Unit status
Illuminated green box
Connected
Flashing green box Selected
Flashing green Processing
Illuminated green
Flashing red
Processing result: Normal
Processing result: Problem
18 / 38
ABOUT THE APPLICATION OPERATION WINDOWS
Unit data
The following data for the units which are connected is extracted and displayed.
If you click on the icon for a unit, the unit name (model number) and firmware version for that unit will be displayed.
*
The box containing this data can be moved by dragging it with the mouse.
19 / 38
ABOUT THE APPLICATION OPERATION WINDOWS
Log window
This function displays the operating history for Etube Project and the operating conditions when diagnosis was carried out.
The following shortcut keys can be used to carry out tasks in the log window.
Keyboard operation Operation
Ctrl+A Select all logs.
Ctrl+C
Ctrl+S
Copy selected logs.
Open the “Save Log File” dialog box.
All logs
This function displays both operation logs and communication logs together.
To identify the different types of logs, the characters in operation logs and communication logs are displayed using different specified colors.
Operation logs
Only operation histories for Etube Project are displayed.
When the operation tab is selected, a message showing operation logs for Etube Project is displayed.
The characters in the operation logs are displayed in green.
Communication logs
Only the communication history between the SMPCE1 and each unit are displayed.
When the communication tab is selected, a message showing logs of communication between the
SMPCE1 and all other units is displayed.
The characters in the communication logs are displayed in blue.
20 / 38
CUSTOMIZE
CUSTOMIZE
This function is used to customize the gear shifting system.
1. Click “Customize” in the main window.
2. Connect the SMPCE1 and the other units, and click [Next] in the unit connection standby window to move to the Customize menu window.
Note:
*
Never connect or disconnect the battery and the units after you have clicked [Next] in the unit connection standby window. If this is not observed, it may damage the SMPCE1 unit
or the other units.
(Unit connection standby window)
3. Click [Shifting switch function settings] or [Rear derailleur adjustment settings] in the Customize menu window to move to the respective setting windows.
(Customize menu window)
21 / 38
CUSTOMIZE
Shifting switch function settings
This function changes the functions of the ST6770 and SWR600 shifting switches.
1.
Display the Customize menu window. (Refer to page 21 for details on the operating procedure.)
2. Click [Shifting switch function settings] in the Customize menu window.
3. Use the pulldown menus in the Shifting switch function settings window to select the desired function, and then click [Establish].
The main functions that can be selected are as follows.
Pulldown menu Description
FD_UP Shifts the front derailleur from a smaller chainring to a larger chainring.
FD_DOWN
RD_UP
RD_DOWN
Shifts the front derailleur from a larger chainring to a smaller chainring.
Shifts the rear derailleur from a larger sprocket to a smaller sprocket.
Shifts the rear derailleur from a smaller sprocket to a larger sprocket.
(Shifting switch function settings window)
22 / 38
CUSTOMIZE
Rear derailleur adjustment settings
This lets you adjust the rear derailleur.
1.
Display the Customize menu window. (Refer to page 21 for details on the operating procedure.)
2. Click [Rear derailleur adjustment settings] in the Customize menu window.
3. Click [Rear derailleur adjustment method] in the Rear derailleur adjustment settings window to display a separate window with details on the adjustment method.
4. Follow the instructions in the window and then click [Establish].
*
The front derailleur and the rear derailleur will not operate while this procedure is being carried out, even if you operate the ST6770 or the SWR600 shifting switches.
*
Rotate the crank arms while carrying out operations which are related to adjustment and gear shifting.
23 / 38
CUSTOMIZE
The main functions for carrying out adjustment are as follows.
Label Button Description
Adjustment setting Down ()
Up (+)
Moves the guide pulley toward the inside ( display direction).
Moves the guide pulley toward the outside (+ display direction).
Rear derailleur gear shifting
Setting value Displays the current setting value.(15 15)
Down () Shifts the rear derailleur from a smaller sprocket to a larger sprocket ( display direction).
Up (+) Shifts the rear derailleur from a larger sprocket to a smaller sprocket (+ display direction).
No. of gears Displays the current number of sprockets.(1 10)
*
The adjustment bolt judgment window may be displayed while rear derailleur gear shifting operations are being carried out.
If this happens, follow the instructions in the window to adjust the adjustment bolt.
(Rear derailleur adjustment settings window)
24 / 38
PROBLEM DIAGNOSIS
PROBLEM DIAGNOSIS
When a single unit or multiple units are connected, this function checks their operation and identifies any units which have a problem.
Click [Problem diagnosis] in the main window to move to the problem diagnosis window.
(Problem diagnosis window)
25 / 38
PROBLEM DIAGNOSIS
Flow of problem diagnosis
Problem diagnosis starts from [System diagnosis] which diagnoses all units which are currently connected.
If the results of system diagnosis show that there might be a problem with one of the units, lastly connect the SMPCE1 by itself and then carry out the procedure in [Standalone diagnosis] to determine which units have a problem.
No problem
System diagnosis Finish
Problem
Standalone diagnosis
(Carry out for units which may have a problem as reported by system diagnosis.)
Standalone diagnosis
(Connect units which may have a problem as reported by standalone diagnosis as standalone units and then carry out.)
Replace the unit
Return to system diagnosis
Replace the electric wires
Return to system diagnosis
26 / 38
PROBLEM DIAGNOSIS
System diagnosis
1. Display the problem diagnosis window. (Refer to page 25 for details on the operating procedure.)
2. Click [System diagnosis] in the problem diagnosis window.
3. In the connected unit selection window, select the connected units and the number of each which are connected, and then click [Next].
*
You can also select the unit names and numbers by clicking the unit icons which appear in the bicycle window.
(Connected unit selection window)
27 / 38
PROBLEM DIAGNOSIS
4. Connect the SMPCE1 and the other units, and click [Next] in the unit connection standby window.
Note:
*
Never connect or disconnect the battery and the units after you have clicked [Next] in the unit connection standby window. If this is not observed, it may damage the SMPCE1 unit
or the other units.
(Unit connection standby window)
*
If the number of units which are recognized at this time is smaller than the units and the numbers connected which were selected in step 3, the connection error window will be displayed. If the problem is not resolved even after you have checked the connections and overwritten the initial firmware, there may be a problem with the units or with the electric wires.
5. Select the units to be diagnosed in the unit selection window, and then click [Start diagnosis] to start the system diagnosis. When system diagnosis starts, diagnosis is carried out on each of the selected units in turn.
(Unit selection window)
28 / 38
PROBLEM DIAGNOSIS
6. While system diagnosis is in progress, follow the instructions which appear on the screen to carry out the diagnosis.
*
If you click [Skip], the diagnosis operations for the unit which is currently being diagnosed will be skipped.
*
For diagnosis of the front derailleur and the rear derailleur, rotate the crank arms while following the instructions on the screen.
*
The adjustment bolt judgment window may be displayed while rear derailleur diagnosis is being carried out.
If this happens, follow the instructions in the window to adjust the adjustment bolt.
The diagnosis statuses displayed on the screen for each unit are as follows.
Diagnosis status Description
Waiting for judgment Units for which diagnosis has not yet started
Diagnosis in progress...
Skip
Unit for which diagnosis is in progress
Units for which diagnosis has been skipped
Normal Units for which the diagnosis result is normal
May have a problem Units for which the diagnosis result shows a possible problem
7. If all units are normal, problem diagnosis ends.
If the results of system diagnosis show that there might be a problem with some of the units, carry out standalone diagnosis.
29 / 38
PROBLEM DIAGNOSIS
Stand-alone diagnosis
1. Display the problem diagnosis window. (Refer to page 25 for details on the operating procedure.)
2. Click [Standalone diagnosis] in the problem diagnosis window.
3. Connect the SMPCE1 and the other units, and click [Next] in the unit connection standby window to move to the unit selection window.
Note:
*
Never connect or disconnect the battery and the units after you have clicked [Next] in the unit connection standby window. If this is not observed, it may damage the SMPCE1 unit
or the other units.
(Unit connection standby window)
30 / 38
PROBLEM DIAGNOSIS
4. Select the units for standalone diagnosis in the unit selection window, and then click [Start diagnosis] to start the standalone diagnosis.
*
You can also select units by clicking the unit icons which appear in the bicycle window.
(Unit selection window)
5. While standalone diagnosis is in progress, follow the instructions which appear on the screen to carry out the diagnosis.
*
If you click [Skip], the diagnosis operations for the unit which is currently being diagnosed will be skipped.
*
For diagnosis of the front derailleur and the rear derailleur, rotate the crank arms while following the instructions on the screen.
6. If all units are normal, problem diagnosis ends.
31 / 38
UPDATING FIRMWARE
UPDATING FIRMWARE
This function is used to update the firmware for each unit to the desired version.
*
The firmware is downloaded via the Internet.
1. To start updating the firmware, click [Update firmware] in the main window.
*
Updating the firmware for the SMBMR1 can only be carried out while the battery is disconnected.
2. In the connected unit selection window, select the connected units and the number of each which are connected, and then click [Next].
*
You can also select the unit names and numbers by clicking the unit icons which appear in the bicycle window.
(Connected unit selection window)
32 / 38
UPDATING FIRMWARE
3. Connect the SMPCE1 and the other units, and click [Next] in the unit connection standby window.
Note:
*
Never connect or disconnect the battery and the units after you have clicked [Next] in the unit connection standby window. If this is not observed, it may damage the SMPCE1 unit
or the other units.
(Unit connection standby window)
*
If the number of units which are recognized at this time do not match the units and the numbers connected which were selected in step 2, the connection error window will be displayed. If the problem is not resolved even after you have checked the connections, there may be a problem, so carry out the procedure in “PROBLEM DIAGNOSIS” on page 25.
4. Select the units to have their firmware updated and the firmware versions to use for updating in the unit selection window, and then click [Update] to begin updating the firmware.
(Unit selection window)
33 / 38
UPDATING FIRMWARE
*
Make sure that the PC does not switch into standby while updating of the firmware is in progress.
If the PC switches to standby, Etube Project processing will be interrupted and the screen display will return to the main window.
*
Do not disconnect the USB cable or the electric wires, remove the battery or turn off the power for the PC while updating of the firmware is in progress.
*
When connecting the battery to carry out firmware updating, make sure that the battery is sufficiently charged so that it does not run out of charge while updating of the firmware is in progress.
*
If you click the [Cancel] button, updating of the firmware will be canceled. However, it will not be canceled until updating of the firmware for the current unit has finished.
*
You cannot shut down the application while updating of the firmware is in progress.
The update statuses displayed in the window are as follows.
Update status Description
Waiting for update
Updating in progress...
Units for which updating has not yet started
Unit for which updating is in progress
Normal end Units for which updating ended normally
5.
When updating of the firmware is complete, the firmware update complete window will be displayed, and the names of the units which were updated and their firmware versions will also be displayed.
6. If you update the firmware while the battery is connected, be sure to disconnect the battery and reconnect it again after the firmware update is complete before using the bicycle. If you do not disconnect and then reconnect the battery before using the bicycle, the system may not operate correctly.
If an error occurs while updating firmware
If an error occurs during updating of the firmware, an error window will be displayed.
If an error occurs while updating the firmware for a particular unit, that unit may not operate correctly. Be sure to repeat the firmware update for such units.
34 / 38
UPDATING FIRMWARE
Upper limit for number of firmware updates
If updating of the firmware is carried out more than 1000 times for a given unit, the firmware for that unit may no longer update correctly, and so a “WARNING” dialog box will be displayed.
If this warning appears, contact your nearest dealer or bicycle manufacturer in the country of use.
35 / 38
OVERWRITING INITIAL FIRMWARE
OVERWRITING INITIAL FIRMWARE
If the firmware which has been written to a unit becomes corrupted and the unit no longer operates correctly, this function can be used to restore the firmware.
1. To begin overwriting of the initial firmware, click [Overwrite initial firmware] in the main window.
*
When overwriting the initial firmware, connect the units to the SMPCE1 as standalone units.
*
Overwriting the initial firmware for the SMBMR1 can only be carried out while the battery is disconnected.
2. Click the file reference button in the firmware selection window to select the firmware to overwrite.
File reference button
(Firmware selection window)
The filenames for the firmware have the following structure.
dat
Unit name Extension
Firmware version
Filename
ST6770.*. *.*.dat
SWR600.*. *.*.dat
FD6770.*. *.*.dat
RD6770.*.*.*.dat
BMR1.*.*.*.dat
EW67A.*.*.*.dat
PCE1.*.*.*.dat
Applicable unit
ST6770L / ST6770R
SWR600
FD6770
RD6770
SMBMR1
SMEW67AE
SMPCE1
36 / 38
OVERWRITING INITIAL FIRMWARE
Note:
*
Never attempt to change the contents of the firmware files or the filenames. If you do this, it will not be possible to update the firmware correctly, and problems may occur with the units after carrying out firmware updates.
3. Check the firmware version, and then click [Next] to start overwriting the initial firmware.
*
Make sure that the PC does not switch into standby while overwriting of the initial firmware is in progress.
If the PC switches to standby, Etube Project processing will be interrupted and the screen display will return to the main window.
*
Do not disconnect the USB cable or the electric wires or turn off the power for the PC while overwriting of the initial firmware is in progress.
4. When overwriting of the initial firmware is complete, the firmware overwriting complete window will appear and the unit names and the firmware versions will be displayed.
*
If an error occurs during overwriting of the initial firmware, a firmware overwriting error window will be displayed, so repeat the process of overwriting the initial firmware.
37 / 38
ABOUT THIS DOCUMENT
ABOUT THIS DOCUMENT
The contents of this document are subject to revision in the future without notice.
Reproducing or transmitting this document in whole or in part in any form or for any purpose whatsoever without the express written permission of SHIMANO INC. is expressly forbidden. However, this is not to be taken as a limit on the customer’s rights under applicable copyright laws.
SHIMANO INC. may own the rights to any patents, patent applications, trademarks, copyrights and any other intangible property rights contained in this document. Unless otherwise specified, the customer is not granted rights to any patents, trademarks, copyrights or any other intangible intellectual property contained in this document.
REGISTERED TRADEMARKS AND TRADEMARKS
Shimano is a trademark or registered trademark of SHIMANO INC. in Japan and other countries.
Etube Project is a trademark of SHIMANO, INC. in Japan and other countries.
Microsoft®, Windows® XP, Windows Vista
TM
Windows® 7 are registered trademarks or trademarks of
Microsoft Corporation in the United States of America and other countries.
All other company names, product names and service names, etc. are the property of their respective owners.
One Holland, Irvine, California 92618, U.S.A. Phone: +19499515003
Industrieweg 24, 8071 CT Nunspeet, The Netherlands Phone: +31341272222
377 Oimatsucho, Sakaiku, Sakaishi, Osaka 5908577, Japan
Please note: specifications are subject to change for improvement without notice. (English)
38 / 38 06.21.2011
advertisement
Key Features
- Customize gear shifting system
- Adjust rear derailleur settings
- Diagnose problems with connected units
- Update firmware for connected units
- Overwrite initial firmware for corrupted units
- Connect via USB
- Connect to the internet to download latest firmware
- Compatible with various Shimano components
- User-friendly interface
- Comprehensive help documentation