Kenwood PAC/PAC-R Series - Micro Precision Calibration


Add to my manuals
4 Pages

advertisement

Kenwood PAC/PAC-R Series - Micro Precision Calibration | Manualzz

REGULATED DC POWER SUPPLIES

Regulated DC Power Supplies

PAC/PAC-R SERIES

20V/3A

PAC20-3/R

30V/2A

PAC30-2/R

30V/3A

PAC30-3/R

30V/6A

PAC30-6/R

60V/1A

PAC60-1/R

60V/3A

PAC60-3/R

OUTLINE

The PAC/PAC-R Series regulated CV/CC power supplies are designed to provide a compact power supply package with high performance, and ensure excellent reliability as well as excellent design.

Twelve types are available for a variety of requirements.

Whether used individually or operated by series or parallel for greater capacity, the PAC/PAC-R Series ensures excellent performance.

PAC20-3R PAC20-3

98

FEATURES

Low ripple and low noise characteristics

Ripple and noise are kept extremely low by use of the series regulator method, and excellent electrical characteristics are provided.

Simultaneous display (voltage and current)

Using 3-digit LED, voltage and current can be set and confirmed simultaneously.

Floating output terminals

Floating output terminals is provided for either positive or negative ground.

Series/parallel operation (only for PAC-R series)

The output voltage can be increased by series operation, while output current can be increased by parallel operation.

Remote sensing terminal (only for PAC-R series)

PAC-R power supply can monitor the voltage at the load and stabilize voltage at the load.

Remote control terminals (only for PAC-R series)

Remote control terminals on the rear panel can be used for control of output voltage and current by external resistance or voltage.

REGULATED DC POWER SUPPLIES

PAC/PAC-R SERIES

PAC30-3R

99

PAC30-3

REGULATED DC POWER SUPPLIES

SPECIFICATIONS

Model PAC20-3/R PAC30-2/R

Output

Output voltage

Output current

0 to 20V

0 to 3A

0 to 30V

0 to 2A

Constant voltage characteristics input regulation For AC ±10% fluctuation 4mV 5mV

Load regulation For 0 to 100% fluctuation 4mV 5mV

Ripple and noise 10Hz to 1MHz 0.5mV rms

Ripple peak 10Hz to 20MHz 3mVp-p

Transient response Standard value (current 5%to100%) 50µ Typical

Temperature coefficient Standard value 100ppm/°C Typical

Remote control (PAC-R only)

Controlled by external voltage 0 to 10V Output voltage 0 to 20V ± 5% 0 to 30V ±5%

Controlled by external resistance 0 to 10k

Output voltage 0 to 20V ±5% 0 to 30V ±5%

Constant current characteristics

Input regulation For AC ±10% fluctuation 2mA

Load regulation For 0 to 100% fluctuation 10mA

Ripple and noise 10Hz to 1MHz 2mA rms

Temperature coefficient Standard value 250ppm/°C Typical

Remote control (PAC-R only)

Controlled by external voltage 0 to 10V Output current 0 to 3A ±5% 0 to 2A ±5%

Controlled by external resistance 0 to 10k

Output current 0 to 3A ±5% 0 to 2A ±5%

Constant voltage operation indication CV (green LED) lights

Constant current operation indication OC (red LED) lights

Digital meter Indication

Voltmeter indication Red 3-digit LED Max.99.9V,fixed range

Accuracy Output ON ±(0.2% rdg+2digits)

Ammeter indication Red 3-digit LED Max.99.9V,fixed range

Accuracy Output ON ±(1.0% rdg+3digits)

Functions

Output ON/OFF Output on/off is possible

Remote (PAC-R only)

Remote sensing PAC-R series only Possible by using the (+S) and (-S) terminals on the panel.

Series operation Master/slave mode, PAC-R series only One control series operation is possible

Parallel operation Master/slave mode, PAC-R series only One control parallel operation is possible

Operating conditions (Indoor use only)

Altitude

Overvoltage category

Up to 2000m

Category 2

Operating temperature and humidity range 0 to 40°C 10 to 80%RH

Storage temperature and humidity range -20 to 60°C 10 to 85%RH

Cooling method Natural air cooling

Output polarity +(red), -(white),GND(black),

Ground proof voltage ±200V

Insulation resistance Between chassis and input supply DC500V 30M

Between chassis and input terminal DC500V 20M

Power

Input power Voltage fluctuation: within±10% AC100V/120V/220V/230V, selectable

Input power consumption (Approx.) 175VA/125W 165VA/115W

Dimension, weight

Dimension (W

×

H

×

D) mm

Max.dimensions (W

×

H

×

D) mm

Weight (kg)

Accessories

134

×

147

×

322

138

×

162

×

345

5.9

134

138

5.8

×

×

147

162

×

×

322

345

Instruction manual (1), power cable (1)

PAC30-3/R

0 to 3A

PAC30-6/R

0 to 6A

1mV rms

PAC60-1/R

0 to 60V

0 to 1A

8mV

8mV

PAC60-3/R

0 to 3A

4mVp-p

0 to 60V±5%

0 to 60V ±5%

6mA 2mA 3mA

15mA 10mA 15mA

3mA rms 1mA rms 2mA rms

0 to 3A ±5% 0 to 6A ±5% 0 to 1A ±5% 0 to 3A±5%

0 to 3A ±5% 0 to 6A ±5% 0 to 1A ±5% 0 to 3A ±5%

REGULATED DC POWER SUPPLIES

PAC/PAC-R SERIES

(Remote control is possible only for the PAC-R series)

Compensation possible up to 1V one way.

(within the ground proof voltage).

(only for same models).

*grounding possible

235VA/165W

134

×

147

×

322

138

×

162

×

345

6.6

450VA/370W

210

×

147

×

324

210

×

163

×

347

10

145VA/100W

134

×

147

×

322

138

×

162

×

345

5.8

380VA/300W

210

×

146

×

324

210

×

163

×

347

10

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement