UL9010 Ultra-Lok Tool

UL9010 Ultra-Lok Tool
Operating
Instructions
UL9010
Ultra-Lok Tool
UL9010 Ultra-Lok Tool
Table of Contents
Warranty
2
Safety Guidelines
2
Setup Instructions
3-4
Settings
5
Parts List
6
Troubleshooting
7
Assembly Instructions
7-8
Clamp Application
Free-End
Preformed
9-10
11
Maintenance
13
Blade Change
14
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
Ph: 1-800-525-0758
Fax: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 1 of 14
Document # P44987 rev. I
© Copyright
BAND-IT-IDEX, Inc. 2008
All rights reserved
UL9010
Ultra-Lok Tool
Warranty
Safety Guidelines
Warranty:
For warranty information visit the following URL
www.BAND-IT-IDEX.com/Warranty.html
NOTE: Any performance data published herein is based on laboratory tests, which cannot duplicate conditions that may
be encountered in field installations. Such conditions may vary results substantially from those shown (such as abuse in
handling and installation, failure to follow recommended handling and installation practices, abnormal environmental
conditions, disregard of operating instructions for BAND-IT tools or non-recommended combinations of BAND-IT
products). BAND-IT cannot be responsible for performance characteristics from such variables.
METABO Drill is covered solely by the Metabo warranty as described in the Metabo literature. BAND-IT does not extend
any warranty of any kind to the drill.
General Safety Guidelines
Read and understand all instructions prior to operating this tool
•
•
•
•
•
•
Maintain a safe working environment. Keep your work area clean and well lighted. Cluttered benches and dark
areas invite accidents.
Protect yourself and others in the area with proper safety gear including protective eye ware.
When applying clamps, care should be taken to make certain that fingers are not in the way of the clamp being
applied. Tensioning the clamp can be stopped immediately by releasing the trigger. This manual contains
detailed instructions. The operator is advised to read it and become familiar with instructions prior to operating
the tool.
Clamping objects other than hose requires similar precautions.
Improperly tightened clamps may result in dangerous hose assemblies, which could cause injuries or property
damage.
Abuse or use of a hose outside the manufacturers recommended conditions may cause it to quickly deteriorate
and become a safety hazard. This could result in serious injury or property damage. Inspect and test hose
assemblies frequently.
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
Ph: 1-800-525-0758
Fax: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 2 of 14
Document # P44987 rev. I
© Copyright
BAND-IT-IDEX, Inc. 2008
All rights reserved
UL9010
Ultra-Lok Tool
Setup
Instructions
Warning:
Always wear safety glasses when operating this tool. Keep both hands away from clamp being tensioned. Use
common sense, squeezing force of ¾” clamp can reach as high as 2 tons. Never attempt to clamp objects which
can shatter, or otherwise cause bodily harm.
Note:
Read safety instructions and operator’s manual of the METABO electric drill. Check to make sure drill is properly
set up for use with BAND-IT Ultra-Lok tool as follows:
Drill spindle has adapter clutch (BAND-IT # M03990) installed in place of standard drill chuck.
Gear selector must be on slow (turtle symbol), and set as shown on page 4.
Impact drive must be disengaged and set to (drill symbol).
1. Plug drill into standard 115V AC, 60 Hz outlet. If using and extension cord, a 14 gauge cord is suggested for
lengths up to 50 feet, 12 gauge cord required if running longer than 50 feet, 10 gauge cord if running over 100 feet.
2. To mount drill onto BAND-IT Ultra-Lok tool: First use the two #10-32 x 3/8” screws supplied with tool to tighten tool
adapter body to the tool. With adapter clamp on tool adapter body, insert drill into back of tool through the adapter
clamp. Turn drill manually to desired position in relation to tool. Press the drill firmly into tool. Actuate drill if
necessary to engage drill safety clutch (M03990) to tension screw. Tighten clamp screw while keeping the drill
firmly pressed against the tool. To remove drill from tool: loosen the clamp screw and pull drill away from the tool.
NOTE: When tightening the adapter clamp screw, safety clutch (M03990) must be engaged with tension screw
inside of BAND-IT tool.
3. This tool was designed for, and can only be used with BAND-IT Ultra-Lok clamps. Do not attempt to use on any
other type of clamp, it may damage tool. Note: An optional adapter can be purchased to apply ½” Ultra-Lok clamp,
see pages 6 and 9 of this manual.
Use only with BAND-IT ¾” Ultra-Lok Free-End and Preformed Clamps
Tension Block Position
Viewing Slot
Adapter Clamp
M08288
(also lubrication syringe access)
Gear Selector
(always set to slow/turtle symbol)
Drill
M23587
Forward
Reverse
Selector
Switch
Tool
Head
Band
Slot
Tool Body
Adapter
M07687
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
Ph: 1-800-525-0758
Fax: 1-800-624-3925
Adapter
Clamp
Tension
Screw
www.BAND-IT-IDEX.com
Page 3 of 14
Document # P44987 rev. I
© Copyright
BAND-IT-IDEX, Inc. 2008
All rights reserved
UL9010
Ultra-Lok Tool
NOTE: Alignment is critical for proper tool function.
Tension Screw
Safety Clutch
Note: Some components are not visible in this illustration.
When installing the tool on the drill, be careful to align the end of the Tension Screw with
the slot in the end of the safety clutch, as shown above.
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
Ph: 1-800-525-0758
Fax: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 4 of 14
Document # P44987 rev. I
© Copyright
BAND-IT-IDEX, Inc. 2008
All rights reserved
UL9010
Ultra-Lok Tool
Settings
Recommended Drill Settings:
(Speed-Torque)
Single Wrap
Double Wrap
*Preformed
½”
C-2
D-2
D-2
¾”
D-2
E-4
E-4
Torque
Selector
Speed
Selector
NOTE: These torque settings are suggested settings only, individual tools should be adjusted for the clamping
application. See pages 9-11.
*IMPORTANT: Larger sizes of preformed clamps (5" and up) may require a lower setting to avoid overstressing the lock and creating potentially unsafe assemblies. Inspect lock per instructions on page 7.
Important: Changing the speed setting will alter tension output. Drill switch must be depressed fully by the operator
to attain correct tension when installing clamps. Tension output may be somewhat different depending on condition
and wear of internal components from tool to tool on same setting.
Pre-set tension is achieved when drill stops and on some models, may pulsate. Excessive pulsation (more than
twice) will result in more tension applied to the clamp.
Use of Alternate Drills
CAUTION !
The UL9010 tool is designed to work mounted securely to the Metabo drill Model SBE 850 IMPULS. Use of any
other drill may result in unsatisfactory performance, hazards to the operator and/or the tool, or unsafe clamps. Use
of alternate drills must be approved in writing by the Vice President of Engineering and Manufacturing at BAND-ITIDEX, Inc. Disregard of this caution voids the warranty of the tool and releases BAND-IT of any and all liabilities
arising from such misuses.
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
Ph: 1-800-525-0758
Fax: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 5 of 14
Document # P44987 rev. I
© Copyright
BAND-IT-IDEX, Inc. 2008
All rights reserved
UL9010
Ultra-Lok Tool
Parts List
Notes:
Apply Item 31 (Grease) to:
Item 4 (Cut off cam)
Item 3 (Cutter knife) at contact point with item 1 (Tool head)
Item 26 (Spring) Before installation
Apply Item 32 (Grease) to:
Item 7 (Tension screw) Threads and at grooved end
Item 2 (Cutter blade) Counter-bore only, after item 14 (Bearing tip) has been
installed.
Item
Part Number
Description
Tighten the following:
1
M00587
Tool Head, Fin. UL
Item 23 (#10-32 Screw)
2
M09787
Cutter Blade, UL
to 60 – 70 in-lbs.
3
M08687
Cutter Knife, UL
Item 22 (1/4-28 Screw)
4
M08987
Cam, Cut-off, UL
to 90 – 110 in-lbs.
5
M09087
Tension Block, Mach., UL
Handle Assembly:
Adjust Item 24 (Plunger) for
6
UL1219
Includes Handle, Handle Grip, and Pins
positive detent action when
7
M00987
Tension Screw, Fin.
item 6 (Handle) is actuated.
8
M08887
Gripper, UL
Part M09887, and its alternate
9
M01787
Plate, Back, Cast/Fin.
M09387, Shear Plate has
10
M09187
Gripper Guide, UL
two cutting edges. This part
11
M02387
Plate, Release, cast/fin.
can be rotated to use the second
12
M00287
Roller, Cut-off, Fin.
edge prior to replacement.
13
M01388
Pin, .187 Dia X 1.50 Long, Fin.
14
M05387
Bearing Tip, Fin.
15
M06587
Ball, ¼” Diameter
16
M02287
Tip, Load Bearing, Fin.
17
M04387
Tripper Bracket, Cast/Fin.
18
M07387
Body, Left, Finished, UL
19
M07487
Body, Right, Finished, UL
20
M07587
Wear Plate, Fin.
21
M05787
Screw, Socket Head Cap, ¼ X 1”
22
J67287
Screw, Socket Head Cap, ¼ X ½”
23
M06187
Screw, Socket Head Cap, #10-32 X 3/8”
24
M02487
Screw, Spring Plunger, ¼-20
NOTE:
25
A33887
Spring, Compression, .180 X .813 Long
Part M09387, (Optional)
26
A53587
Spring, Compression, .300 X 1.00 Long
½” Shear Plate 27
M01487
Pin, Dowel, ¼ Dia X 1.50 Long
Required replacement for # 33
28
M08187
Washer, .128 ID X .238 OD
M09887 shear plate in order to
29
M08087
Rivet, Blind, .125 X .328 Long
install ½” wide Ultra-Lok
30
M07987
Threaded Insert, #10-32
Clamps
31
I16387
Lubricant, Super Lube w/ Teflon (cc)
32
C23187
Lubricant, Black Moly, Hi-Temp (cc)
33
M09887
Shear Plate, ¾”, UL
34
M09387
Shear Plate, ½”, UL (Optional)
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
Ph: 1-800-525-0758
Fax: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 6 of 14
Document # P44987 rev. I
© Copyright
BAND-IT-IDEX, Inc. 2008
All rights reserved
UL9010
Ultra-Lok Tool
Assembly —
Troubleshooting
6
30 2 Places
18
6
28 4 Places
4
23 4 Places
20 2 Places
19
See preceding pages for parts list
29 4 Places
22 4 Places
Troubleshooting
1. Lock slips down in buckle: Verify tightness of blade mounting screws. If lock on clamp is still not adequate,
reduce tension on tool by setting torque control knob to a lower number or reduce speed of the drill. (See “Setting up
proper tension”)
2. Drill makes loud, rapid clicking noise: Make sure hammer drill setting is off and indicator is pointing to drill
symbol. (Hammer symbol on selector knob pointing to back)
3. Drill makes whining noise when clamp gets tight: The drill is equipped with its own internal safety clutch. If this
clutch disengages usually above torque setting 6, reduce torque setting and lubricate tension screw. Do not confuse
this clutch with the coupling between drill and tool.
4. Safety clutch between drill and tool releases prematurely: Make sure tool is fully seated on drill and safety
clutch is fully engaged with tip of tension screw. (Loosen clamping screw and re-tighten while pressing tool into drill).
See page 3.
Note: To prevent safety clutch wear, do not over-use. When tensioning clamp, let drill switch go as tension block
nears its end of travel. Reverse drill and send tension block all the way forward for a second pull on the band.
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
Ph: 1-800-525-0758
Fax: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 7 of 14
Document # P44987 rev. I
© Copyright
BAND-IT-IDEX, Inc. 2008
All rights reserved
UL9010
Ultra-Lok Tool
Assembly
9
Tension Gripper Assembly
32
7
Brush lubricant evenly
on threads.
16
5
17
26 31
2 Places
Tool Head Assembly
8
4
31
24
2 Places
Lubricate
both sides
Component
under spring
load when
assembled.
10
27
21
2 Places
13
11
25
Component
under spring
load when
assembled.
31
*Item#34
M09387 (Optional)
½” Shear Plate Insert
can be substituted for
item # 33
13
12
3
1
33
15
32
14
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
Ph: 1-800-525-0758
Fax: 1-800-624-3925
32
*
2
www.BAND-IT-IDEX.com
Page 8 of 14
See preceding pages for parts
list
Document # P44987 rev. I
© Copyright
BAND-IT-IDEX, Inc. 2008
All rights reserved
Clamp Application
Free-End Clamps
UL9010
Ultra-Lok Tool
Warning: Always wear safety glasses when operating tool.
1. Break off an Ultra-Lok 2. Wrap tie around object to be clamped.
3.
Free-End tie from the roll.
Insert the tie through buckle once for
Slide the buckle onto band
single-wrap or twice for double-wrap.
Double-wrapped clamps have more
with
indented
arrows
than 3 times the loop-tensile strength.
pointing in same direction
and same side up. Slide
DO NOT
buckle all the way onto
FEATHER
band until it comes to a
the drill’s
stop between the two
TRIGGER when
buckle dimples at opposite
tensioning a
end of tie.
clamp.
USE FULL
SPEED OF
TOOL
4. Position the clamp on the
object you are clamping.
Pull the wrapped clamp
hand-tight. Slightly bend
the tail up to keep the
clamp in place.
5. Actuate drill until tension block is all the
way forward against the tool body. Set
drill to clock-wise rotation. With cut-off
handle down as shown, insert clamp tail
into tool head slot. Actuate drill until drill’s
built-in clutch disengages. If tension block
comes near its end of travel, release
actuator switch and reverse drill to pull
more on clamp tail. Excessive use of
disengaging clutch indicated by a loud
ratcheting sound leads to premature wear
of tension screw.
Push all the
way forward to
a solid stop.
DO NOT JAM
THE CUT-OFF
HANDLE
FORWARD
BEYOND
INTENDED
TRAVEL
DURING
OPERATION
6. Do not force tool against clamp,
it may result in a folded clamp
tail.
7. Pull the cut-off handle forward
to cut tail off and form a lock,
then return handle to the down
position. Reverse drill and feed
clamp tail out of tool.
8. Tap down buckle shroud to
complete clamp. Tool is ready
for next clamp.
Incorrect position of
tool while tensioning
Correct position of
tool while tensioning
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
Ph: 1-800-525-0758
Fax: 1-800-624-3925
If desired, you may pre-form a
clamp in the same fashion as
step 2, or use a preformed
clamp in place of a Free-End.
www.BAND-IT-IDEX.com
Page 9 of 14
Document # P44987 rev. I
© Copyright
BAND-IT-IDEX, Inc. 2008
All rights reserved
Clamp Application
Free-End Clamps
UL9010
Ultra-Lok Tool
Inspect buckle on completed clamp and tap down buckle shroud.
Section View
Proper clamp
Installation
FRONT VIEW
Completed Free-End Clamp
(Visually inspect lock)
Lock sheared in center
and formed inside
shroud
Buckle Shroud
Section View
Defective Clamp
installation
Lock has slipped back
under sheared buckle
surface
Shear Surface
Important: Visually inspect lock formed in band as shown. If lock has slipped under the sheared surface of the
buckle, remove clamp and install a new one at reduced tension by lowering the drill clutch torque setting.
SIDE VIEW
Completed Free-End
Clamp with buckle
shroud tapped down
as required
Completed clamp
should appear as
shown.
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
Ph: 1-800-525-0758
Fax: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 10 of 14
Document # P44987 rev. I
© Copyright
BAND-IT-IDEX, Inc. 2008
All rights reserved
UL9010
Ultra-Lok Tool
Clamp Application
Preformed Clamps
Place clamp in desired position on object to be clamped.
Follow steps 5 and 6 on page 5.
Inspect lock in buckle on completed clamp, and then tap down buckle shroud as shown below.
Section View
Proper Clamp
formation
Lock sheared in center and
formed inside shroud
Front View
Completed Clamp
(Visually inspect lock)
Buckle Shroud
Shear Surface
Section View
Improper lock
formation
Lock has slipped back
under sheared buckle
surface
Important: Visually inspect lock formed in band as shown. If lock has slipped under the sheared surface of the
buckle, remove clamp and install a new clamp at reduced tension by lowering the drill clutch torque setting.
Tap down buckle
shroud to complete
clamp
SIDE VIEW
Completed UL Preformed Clamp with
buckle shroud tapped
down as required
When applying clamps on soft, thick-walled hose, tension clamp then wait a full 30
seconds. Clamps may be retensioned by squeezing the actuator switch on the power
unit a second time prior to forming the lock and cutting the excess clamp tail. This
allows hose to “settle” under the band of the clamp. This hose material attribute is
called Cold Flow. Finally, complete clamp by tapping down the buckle shroud as
described above.
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
Ph: 1-800-525-0758
Fax: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 11 of 14
Document # P44987 rev. I
© Copyright
BAND-IT-IDEX, Inc. 2008
All rights reserved
UL9010
Ultra-Lok Tool
Maintenance
1. Lubricate tension screw with molybdenum disulfide lubricant or
equivalent approximately every 500 clamps.
Make sure the tension block is all the way forward against the tool
head. Insert tip of the Lubricating syringe into slot on top of tool
body. Press the tip against the tension screw just behind the tension
block and squeeze out approximately ½” long bead of lubricant.
Remove syringe, and actuate tool without a clamp a couple of times
to spread lubricant evenly on tension screw.
Lubricating
syringe
Reorder
#C23199
To order more lubricant, specify BAND-IT #C23199
2. Every 500-1000 clamps, depending on tension setting, inspect and
repack front bearing with same lubricant. Turn load bearing tip and
small bearing tip over for a new bearing surface.
Bearing Lubrication Detail
Small bearing tip
Item 14
Access hole to push
out components (use
paper clip)
¼” Ball
Item 15
Blade
Item 2
Load bearing tip
Item 16
Blade cavity
(must be packed
with lubricant)
Tool
body
Tool head
Item 1
Tension screw
Item 7
3. To gain access to bearing components: With the tension body
already separated from the power drill, remove blade mounting
screws (2 places) and slide blade free. Paper clip may be used to
push bearing components out of blade. Wipe lubricant from all
components and examine for wear. If ball or bearing tips appear
heavily worn, replace with new parts. Note: ¼” ball is made from
hard tungsten carbide material, do not replace with regular ball
bearing. (A smooth indention from ball in the bearing tips is normal)
Blade mounting
screws
Item 22
4. To re-assemble bearing components: wipe blade cavity clean. Push
small bearing tip into blade cavity. Apply lubricant to ball and push
into blade cavity and fill remaining space with lubricant. Push load
bearing tip firmly into blade cavity, some lubricant will be squeezed
out. Re-attach blade to tool head, making sure that Load Bearing
Tip extends into tension screw. While turning blade mounting
screws into blade, push on blade rearwards. Tighten screws to
approximately 120 in-lbs.
5. When replacing worn blade follow instructions above to properly reassemble bearing components.
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
Ph: 1-800-525-0758
Fax: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 12 of 14
Document # P44987 rev. I
© Copyright
BAND-IT-IDEX, Inc. 2008
All rights reserved
UL9010
Ultra-Lok Tool
Maintenance
6. To replace gripper: Make sure tension block is all the way forward against the tool head. Remove drill.
Remove tool adapter body. Remove only one side of the tool body, not both. Slide gripper out sideways
and replace with a new one. Re-attach tool body side. Caution: Do not push or move tension block while
gripper is out of tool.
Tool Head
Item 1
This tip must align with
the safety clutch
(M03990) on the Metabo
drill. See page 5.
Move tension
block all the way
forward against
the tool head.
Gripper
Item 8
Tension
Screw
Item 7
7. To replace tension screw: Move tension block all the way back (away from tool head) using drill in
tensioning mode (clock-wise). Remove Ultra-Lok tool from drill. Remove the tool adapter body from the
Ultra-Lok tool. Remove blade and load bearing tip from tensioning screw (see bearing detail). Remove
only one side of the tool body, not both. Grasp the smooth barrel on tension screw and pull all the way
forward until tension block is against the tool head. If tension screw is stuck, use a punch and tap the
center of the screw from the back end of the tool. Turn tension screw out of tension block. Lubricate new
tension screw with Molybdenum Disulfide lubricant, or equivalent. Install new tension screw in reverse
order, making sure that back end of tension screw extends well beyond the back end of the tension block.
Push the assembly all the way back and extend the round portion of the tension screw through holes on the
tripper bracket and back guide plate. Reinstall tool body side. Reinstall blade and tighten the blade
mounting screws approximately 120 in-lbs. Reattach tool adapter body to Ultra-Lok tool. Reattach tool to
drill and drive tension block all the way forward.
Note: Drills needing repair must be forwarded to an authorized ‘METABO’ repair center in your area. Be sure
to remove BAND-IT safety clutch (M03990) from drill.
METABO Drill is covered solely by the Metabo warranty as described in the Metabo literature. BAND-IT does
not extend any warranty of any kind to the drill.
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
Ph: 1-800-525-0758
Fax: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 13 of 14
Document # P44987 rev. I
© Copyright
BAND-IT-IDEX, Inc. 2008
All rights reserved
UL9010
Ultra-Lok Tool
Optional ½” Tool
Blade Change
To change out the UL9010 tool to the 1/2” version, the following steps should be followed.
*NOTE: Do not attempt to use 1/2” clamps with 3/4” head. (Adapter change-out: 3-5 minutes)
1. Detach tension body from the drill by loosening the single tensioning bolt on the aluminum collar and separating the
two sections.
2. Remove the blade from head by removing two cap screws (M05787) from the top of the head. It is not necessary to
remove entire head from tool in order to remove blade. (Figure 1) Remove the ¾” adapter plate from the blade.
3. Align the ½” adapter plate (M09387) with the blade (M09787) so that the guide is facing up. Incorrect placement will
not allow bands to be inserted into the tool. (Figure 1)
Note: To convert tool back to ¾”, replace ½” insert with ¾” insert (M09887) and follow same instructions.
Be sure to retain unused shear plate for later use.
4. Attach the blade and ½” adapter plate onto head using the two previously removed cap screws. These cap screws
must be tight to assure proper cut-off of clamp tails.
5. Re-attach drill to tension body making sure the drill and tension body are properly aligned, and tighten the single
adapter cap screw located on the aluminum collar.
6. The UL9010 is not designed to work with traditional band and buckle designs. BAND-IT Ultra-Lok clamps
must be used.
Blade Cap Screw
(M05787) Qty. 2
¼” Ball (M06587)
Bearing Tip (M05387)
Blade (M09787)
Optional ½” Insert
(M09387)
Orient as shown
Blade (M09787)
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
Ph: 1-800-525-0758
Fax: 1-800-624-3925
Figure 2
Figure 1
www.BAND-IT-IDEX.com
Page 14 of 14
Document # P44987 rev. I
© Copyright
BAND-IT-IDEX, Inc. 2008
All rights reserved
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF