Test Report issued under the responsibility of:
TEST REPORT
IEC 60065
Audio, video and similar electronic apparatus - Safety requirements
Report Number. ................................ : 17706907 001
Date of issue .................................... : See cover page
Total number of pages ..................... : See cover page
Applicant’s name .............................. : Hisense Electric Co., Ltd.
Address ............................................ : No. 218, Qianwangang Road, Qingdao Economic & Technology,
Development Zone, Shandong 266555, P.R. China
Test specification:
Standard ........................................... : EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 +A12:2011
Test procedure ................................. : COC-LVD
Non-standard test method................ : N/A
Test Report Form No. ...................... : IEC60065K
Test Report Form(s) Originator ........ : Intertek Semko AB
Master TRF ...................................... : Dated 2010-10
Copyright © 2010 Worldwide System for Conformity Testing and Certification of Electrotechnical
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
Test item description ........................ : LCD TV
Trade Mark ....................................... : Hisense
Manufacturer .................................... : Same as applicant
Model/Type reference ...................... : HE50K3300UWTS, H50M3300, H50M3306, H50M3308
H50MEC3350, H50MEC3355
Ratings ............................................. : AC 220-240V, 50Hz, 145W
Page 3 of 51
Report No.: 17706907 001
Testing procedure and testing location:
Testing Laboratory:
TÜV Rheinland / CCIC (Qingdao) Co., Ltd.
Testing location/ address ........................... : 6F, No.2 Bldg., No.175 Zhuzhou Road, Qingdao 266101,
P.R. China
Associated Laboratory:
Testing location/ address ........................... :
Tested by (name + signature) .......... :
See cover page
Approved by (name + signature)...... :
See cover page
Testing procedure: TMP
Testing location/ address ........................... :
Tested by (name + signature) .......... :
Approved by (name + signature)...... :
Testing procedure: WMT
Testing location/ address ........................... :
Tested by (name + signature) .......... :
Witnessed by (name + signature) .... :
Approved by (name + signature)...... :
Testing procedure: SMT
Testing location/ address ........................... :
Tested by (name + signature) .......... :
Approved by (name + signature)...... :
Supervised by (name + signature) ... :
Testing procedure: RMT
Testing location/ address ........................... :
Tested by (name + signature) .......... :
Approved by (name + signature)...... :
Supervised by (name + signature) ... :
TRF No. IEC60065K
Page 4 of 51
Report No.: 17706907 001
List of Attachments (including a total number of pages in each attachment):
- ATTACHMENT 1 - National Differences (16 pages)
- ATTACHMENT 2 - Photo documentation (10 pages)
Note: Total number of pages in each attachment is indicated in individual attachment.
The EMF test was evaluated in test report No. 17706908 001.
Summary of testing:

The EUT had been evaluated according to the maximum ambient temperature of 35ºC specified by the
manufacturer.

All applicable tests performed with the following condition: 1k Hz audio output power, Max. contrast,
Max. brightness (100%), and max. H. and V. size, USB port is loaded with 0.5A or 1.0A as specified.
Tests performed (name of test and test clause):
Testing location:
Marking and instructions– Clause 5
Unless otherwise indicated, all tests were
performed at the location stated in “Testing
procedure and testing location”.
Heating under normal operation conditions – Clause 7.1
Touch current – Clause 9.1.1.1
Withdrawal of mains plug – Clause 9.1.6
Resistance to external forces – Clause 9.1.7
Surge Test – Clause 10.1
Humidity treatment – Clause 10.2
Insulation resistance & Dielectric strength – Clause 10.3
Touch current under fault condition – Clause 11.1
Fault conditions – Clause 11.2
Heating under fault conditions – Clause 11.2.1
Bump Test – Clause 12.1.1
Impact Test – Clause 12.1.3
Stress Relief Test – Clause 12.1.5
Fixing of actuating elements – Clause 12.2
Working Voltages – Clause 13.2
Electrical connections & mech. Fixings – Clause 17.1
o
Test on plan 10 to the horizontal – Clause 19.1
100N vertical force test – Clause 19.2
Remark: Relevant tests were tested on the sample
registered No. A000301833-001. The sample is an
engineering sample without serial number.
Summary of compliance with National Differences
List of countries addressed:
EU Group Differences, EU Special National Conditions.
Refer to the ATTACHMENT 1 of this test report for details.
TRF No. IEC60065K
Page 5 of 51
Report No.: 17706907 001
Copy of marking plate
The artwork below may be only a draft. The use of certification marks on a product must be authorized by
the respective NCBs that own these marks.
<HE50K3300UWTS>
Remark: The marking plates for the other models are similar with the ones listed above except for
model name.
TRF No. IEC60065K
Page 6 of 51
Report No.: 17706907 001
Test item particulars .................................................. :
Classification of installation and use ........................... : Class II
Supply Connection ....................................................... : Detachable supply cord
Possible test case verdicts:
- test case does not apply to the test object ................. : N/A (Not Applicable)
- test object does meet the requirement....................... : P (Pass)
- test object does not meet the requirement ................ : F (Fail)
Testing:
Date of receipt of test item ............................................ : See cover page
Date (s) of performance of tests ................................... : See cover page
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
comma /
point is used as the decimal separator.
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided................................................................ :
Yes
Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .............................. : Hisense Electric Co., Ltd.
No. 218, Qianwangang Road, Qingdao Economic &
Technology, Development Zone, Shandong 266555,
P.R. China
General product information:
The EUTs are ordinary LCD TVs with LED backlight, which are normally for home use within the scope of
IEC/EN 60065.
All listed models are identical except for model name.
The EUTs are class II apparatus, which mainly contain AC inlet, non-approved class II construction power
supply board, LCD panel, mainboard with tuner and speakers. All parts are covered by enclosures and
fixed with screws. For critical components detail refer to table14.
The EUTs are operated up to 2000m above sea level as declared by the manufacturer.
No wall mounting brackets accessories provided with the EUTs.
TRF No. IEC60065K
Page 7 of 51
Report No.: 17706907 001
IEC 60065
Clause
Requirement + Test
3
General requirements
Safety class of the apparatus .................................. :
4
General test conditions
4.1.4
Ventilation instructions require the use of the test
box
5
Marking and instructions
5.1
5.2
Result - Remark
Verdict
P
Class II
P
P
Measured according to proper
ventilation conditions specified
in user’s manual.
P
P
Comprehensible and easily discernible
Markings are permanent,
comprehensible and easily
discernible on the apparatus.
P
Permanent durability against water and petroleum
spirit
The label and marking were
rubbed with cloth soaked with
water for 15s then again
soaked with petroleum spirit for
15s. After the test there was no
damage to the label and
marking. The marking didn’t
fade. There was neither curling
nor lifting of the label edge.
P
a) Identification, maker .............................................: See marking label
P
b) Model number or type reference ..........................: See marking label
P
c) Class II symbol if applicable ................................: Used according to IEC 604175172.
P
d) Nature of supply ....................................................: Used according to IEC 604175032.
P
e) Rated supply voltage ...........................................: See marking label
P
f) Mains frequency if safety dependant ...................: See marking label
P
g) Rated current or power consumption for
apparatus supplied by supply apparatus for general
use ............................................................................:
N/A
Measured current or power consumption ................:
N/A
Deviation % (max 10%) ...........................................:
N/A
h) Rated current or power consumption for apparat- For use with single phase
us intended for connection to an a.c. mains supply .: mains supply.
P
Measured current or power consumption ................: See below
P
Measured current or power consumption for
See test data in appended
Television set ............................................................: table 7.1.
P
Deviation % (max 10%) ...........................................: Not more than 10%
P
a) Earth terminal
Class II apparatus
N/A
b) Hazardous live terminals
No such terminals
N/A
TRF No. IEC60065K
Page 8 of 51
Report No.: 17706907 001
IEC 60065
Clause
Requirement + Test
Result - Remark
c) Markings on supply output terminals
For USB, DC 5V, 0.5A (Max.)
or DC 5V, 1.0A (Max.)
P
a) Use of triangle with exclamation mark
The symbol was marked on
circuit diagram for safety
related components.
P
b) marking on loudspeaker grille, IEC 60417-5036
No such construction.
5.4
Instructions for use
Instruction manual for safety
was available and English
version was checked.
P
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc.
Provided in user manual.
P
b) Hazardous live terminals, instructions for wiring
No such terminals.
N/A
c) Instructions for replacing lithium battery
No such battery used.
N/A
d) Class I earth connection warning
Class II apparatus.
N/A
e) Instructions for multimedia system connection
Provided in user manual.
5.3
Provided in user manual.
h) Warning: protective film on CRT face
5.4.2
a-b) Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
N/A
P
N/A
f) Special stability warning for attachment of the
apparatus to the floor/wall
g) Warning: battery exposure to heat
Verdict
P
N/A
MAINS plug of detachable
supply cord used as
disconnect device.
P
c) Instructions for permanently connected
equipment
N/A
Marking, signal lamps or similar for completely
disconnection from the mains
N/A
6
Hazardous radiation
N/A
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
6.2
No ionizing radiation in the
apparatus.
N/A
Ionizing radiation under fault condition
N/A
Laser radiation, emission limits to IEC 60825-1:2007 No laser radiation in the
...................................................................................: apparatus.
N/A
Emission limits under fault conditions ......................:
N/A
7
Heating under normal operating conditions
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated
(see appended table)
P
7.1.1
Temperature rise of accessible parts
(see appended table)
P
7.1.2
Temperature rise of parts providing electrical
insulation
(see appended table)
P
TRF No. IEC60065K
P
Page 9 of 51
Report No.: 17706907 001
IEC 60065
Clause
Requirement + Test
7.1.3
Temperature rise of parts acting as a support or as a (see appended table)
mechanical barrier
P
7.1.4
Temperature rise of windings
(see appended table)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
o
mains carrying a current > 0,2 A at least 150 C
Phenolic bobbin material used
for transformers and line filters
were acceptable without further
test. Primary connector not
considered as such part.
P
8
Constructional requirements with regard to the protection against electric
shock
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
Considered.
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
No such devices or parts
intended to be operated by
hand.
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
No such material used.
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the
removal of a cover which can be removed by hand
No such removable covers.
N/A
8.5
Class I equipment
Class II equipment.
N/A
8.6
Result - Remark
Verdict
P
P
N/A
P
Basic insulation between hazardous live parts and
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
N/A
Protective earthing terminal
N/A
Class II equipment and Class II constructions within
Class I equipment
Class II equipment.
P
Double or reinforced insulation between hazardous
live parts and accessible parts
Reinforced or double insulation
provided between primary
circuits and secondary circuits
in power supply board unit and
between live parts and
accessible surface.
P
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3
P
Basic insulation bridged by components complying
with 14.3.4.3.
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
TRF No. IEC60065K
N/A
Page 10 of 51
Report No.: 17706907 001
IEC 60065
Clause
Requirement + Test
Result - Remark
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
Verdict
Approved Y1 capacitors used.
P
8.7
This clause is void
N/A
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
Bobbin of T831: 0.8 mm ;
Bobbin of T901: 0.6 mm.
P
Reinforced insulation > 0,4 mm (mm) .................... :
Approved optocoupler and
insulation sheet under power
supply board used. See
appended table 14 for details.
P
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
Basic or supplementary insulation, at least two
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which
meet 10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
8.9
8.10
8.11
Insulating tape in transformer
T831.
P
Adequate insulation between internal hazardous live Reinforced insulation provide
conductors and accessible parts
for PVC insulated primary wire
which has a thickness of at
least 0.4mm.
P
Adequate insulation between internal hazardous live Secondary wires to signal
parts and conductors connected to accessible parts board are fixed far away from
hazardous live parts. Insulation
only for correct function.
P
Double insulation between conductors connected to Approved supply cord used.
the mains and accessible parts.
P
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
P
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
P
Vibration test carried out ........................................ :
No
—
8.12
This clause is void
8.13
Adequate fastening of windows, lenses, lamp covers No such component.
etc. (pull test 20 N for 10 s)
8.14
Adequate fastening of covers (push/pull test 50 N
for 10 s)
8.15
No risk of damage to the insulation of internal wiring Wires or cables are fixed well
due to hot parts or sharp edges
so as to avoid such hazards.
TRF No. IEC60065K
N/A
For back cover.
N/A
P
P
Page 11 of 51
Report No.: 17706907 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
8.16
Only special supply equipment can be used
Not such equipment.
8.17
Insulated winding wire without additional interleaved Approved triple insulation
insulation
winding wire used in T902.
Insulating tape used between
the interleaved windings.
8.18
Endurance test as required by 8.17
8.19
Disconnection from the mains
The MAINS plug on supply
cord used.
P
8.19.1
Disconnect device
See above
P
All-pole switch or circuit breaker with >3mm contact
separation
MAINS switch not considered
as disconnection device.
N/A
P
N/A
N/A
8.19.2
Mains switch ON indication
N/A
8.20
Switch not fitted in the mains cord
8.21
Bridging components comply with clause 14
N/A
8.22
Non-separable thin sheet material
N/A
9
Electric shock hazard under normal operating conditions
P
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
No such high hazardous
voltage.
9.1.1.1
a) Open circuit voltages
See below
P
b) Touch current measured from terminal devices
using the network in annex D ................................. :
The open-circuit voltage of the
apparatus exceeds 60Vd.c. or
35Vpeak and the touch current
measurement was conducted.
Refer the test results in
appended table.
P
MAINS switch mounted on the
bracket.
c) Discharge not exceeding 45 μC
P
N/A
P
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
P
9.1.2
No hazardous live shafts of knobs, handles or levers No knobs, handles or levers
are hazardous live.
P
9.1.3
Ventilation holes and other holes tested by means of Compliance is checked.
4 mm x 100 mm test pin
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin Compliance is checked.
(10 N); test probe D of IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
TRF No. IEC60065K
Applied to antenna and all
input/output signal connectors.
N/A
Page 12 of 51
Report No.: 17706907 001
IEC 60065
Clause
Requirement + Test
Result - Remark
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
2s after withdrawal of the
mains plug, the pins of the plug
is not hazardous live.
The measured voltage is 24V.
If one bleeder resistance
opened, the measured voltage
is 26V.
If C is not greater than 0,1 μF no test needed
See above
N/A
Resistance to external forces
See below
P
a) Test probe 11 of IEC 61032 for 10 s (50 N)
No hazards.
P
b) Test hook of fig. 4 for 10 s (20 N)
No hazards.
P
9.1.7
c) 30 mm diameter test tool for 5 s (100 or 250 N)
Verdict
P
N/A
9.2
No hazard after removing a cover by hand
No removable cover by hand.
10
Insulation requirements
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
100MΩ between main plug
and tuner after surge test.
P
10.2
Humidity treatment 48 h or 120 h ........................... :
30°C, humidity 93%, 48h.
P
10.3
Insulation resistance and dielectric strength between (see appended table)
mains terminals
P
P
N/A
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
N/A
(see appended table)
P
11
Fault conditions
P
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
No flame, solder soften or
became fluid during tests.
P
Flames extinguish within 10 seconds
N/A
No hazard from softening solder
N/A
P
Soldered terminations not used as protective
mechanism
11.2.1
Measurement of temperature rises
(see appended table)
P
11.2.2
Temperature rise of accessible parts
(see appended table)
P
11.2.3
Temperature rise of parts, other than windings and
printed boards, providing electrical insulation
(see appended table)
P
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
(see appended table)
P
11.2.5
Temperature rise of windings
(see appended table)
P
TRF No. IEC60065K
Page 13 of 51
Report No.: 17706907 001
IEC 60065
Clause
Requirement + Test
Result - Remark
11.2.6
Temperature rise of printed boards shall not exceed
the limits of table 3 by max. 100 K for max. 5 min
Not exceed the values in given
in table 3.
Verdict
N/A
Printed circuit boards (PCB) classified as V-0
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
N/A
a) Temperature rise of printed circuit boards
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ............... :
N/A
b) Temperature rise of printed circuit boards
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.7
Temperature rise of parts not subject to the limits of (see appended table)
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
P
12
Mechanical strength
P
12.1.1
Bump test where mass >7 kg
12.1.2
Vibration test
12.1.3
Impact hammer test
3 blows with 0.5J applied to
every point of weak part of the
exterior.
P
Steel ball test
2J for non-ventilated solid
areas of enclosure.
P
The mass of the EUT is more
than 7.0kg.
P
N/A
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg
12.1.5
Thermoplastic enclosures stress relief test
A sample consisting of the
complete apparatus is
subjected in a circulating air
oven to a temperature 70°C,
after the test, no hazardous
live parts can be accessible.
P
12.2
Fixing of knobs, push buttons, keys and levers
50N pulling force used on main
switch.
P
12.3
Remote controls with hazardous live parts
No hazardous live parts within
remote control.
N/A
12.4
Drawers (pull test 50 N, 10 s)
No such components.
N/A
12.5
Antenna coaxial sockets providing isolation
No such components.
N/A
12.6
Telescoping or rod antennas construction
No such components.
N/A
12.6.1
Telescoping or rod antennas securement
No such components.
N/A
TRF No. IEC60065K
N/A
Page 14 of 51
Report No.: 17706907 001
IEC 60065
Clause
Requirement + Test
13
Clearances and creepage distances
13.1
Clearances in accordance with 13.3
See clause 13.3
P
Creepage distances in accordance with 13.4
See clause 13.4
P
13.2
Determination of working voltage
Test voltage is AC 240V, see
appended table
P
13.3
Clearances
See appended table
P
13.3.1
General
See below.
P
13.3.2
Circuits conductively connected to the mains comply See appended table
with table 8 and, where applicable, table 9 ............. :
13.3.3
Circuits not conductively connected to the mains
comply with table 10
N/A
13.3.4
Measurement of transient voltages
N/A
13.4
Creepage distances
See appended table
P
Creepage distances greater than table 11 minimum
values
See appended table
P
13.5
Printed boards
No such printed boards.
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
13.7
Result - Remark
Verdict
P
P
N/A
P
Conductive parts along reliably cemented joints
comply with 8.8
Optocouplers are approved
component. (see sub-clause
14.11).
P
Temperature cycle test and dielectric strength test
Optocouplers are approved
component. (see sub-clause
14.11).
P
500V test for transformers, magnetic coupler and
similar devices, if insulation is relied upon for safety
No such devices.
Enclosed, enveloped or hermetically sealed parts
not conductively connected to the mains, clearances
and creepage distances as in table 12
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
14
Components
14.1
Resistors
TRF No. IEC60065K
N/A
N/A
Optocoupler used in power
supply board. See appended
table 14.
P
P
N/A
Page 15 of 51
Report No.: 17706907 001
IEC 60065
Clause
14.2
Requirement + Test
Result - Remark
a) Resistors between hazardous live parts and
accessible metal parts
No such construction
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
No such construction
N/A
Resistors separately approved ............................... :
No such resistors.
N/A
Capacitors and RC units
See below.
P
Capacitors separately approved :
Verdict
Yes see table 14
P
nd
Approved Y1 capacitors used
in power supply board.
P
nd
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
edition ……:
14.2.2
X capacitors tested to IEC 60384-14, 2
edition ……:
Approved X2 capacitors used
in power supply board.
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ..................... :
No such X2 capacitors used
14.2.5
Capacitors with volume exceeding 1750 mm³, where The main fuse will break when
short-circuit current exceeds 0,2 A: compliance with short-circuit the capacitors
IEC 60384-1, 4.38 category B or better ................. : after main fuse. No possibility
of flammability.
P
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................ :
Capacitors C860 and C865
with metal enclosure
P
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal ....................................................................... :
No such capacitors used
Inductors and windings
See below.
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
Tested in equipment.
N/A
Transformers and inductors marked with
manufacturer's name and type ............................... :
See appended table.
P
Transformers and inductors separately approved . :
Transformers and inductors
are tested within the
equipment.
General
See below.
14.3
14.3.1
14.3.2
Insulation material complies with clause 20.1.4
N/A
N/A
P
N/A
P
P
14.3.3
Constructional requirements
See below.
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
See appended table.
P
14.3.3.2
Transformers meet the constructional requirements
Compliance is checked by
inspection.
P
14.3.4
Separation between windings
See below.
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation).............................. :
Compliance with double or
reinforced insulation. See
appended table.
P
Coil formers and partition walls > 0,4 mm
TRF No. IEC60065K
P
Page 16 of 51
Report No.: 17706907 001
IEC 60065
Clause
Requirement + Test
Result - Remark
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
No such construction.
N/A
14.3.4.3
Separating transformers with at least basic
insulation
No such construction.
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
P
Compliance with double or
reinforced insulation. See
appended table.
Coil formers and partition walls > 0,4 mm
14.3.5.2
14.4
Verdict
P
P
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
No such construction.
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
No such construction.
N/A
High voltage components
All components operating
voltage is below 4kV.
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
N/A
14.5
Protective devices
14.5.1.1
Approved fuse used
P
Protective devices used within their ratings
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
P
No such component.
N/A
b) Thermal cut-outs tested as part of the submission No such component.
N/A
a) Thermal links separately approved
No such component.
N/A
b) Thermal links tested as part of the submission
No such component.
N/A
14.5.1.3
Thermal devices re-settable by soldering
No such component.
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
See appended table 14.
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... :
F801 T 6.3A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ............... :
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
14.5.1.2
a) Thermal cut-outs separately approved
TRF No. IEC60065K
P
The fuse cannot be replaced
without the use of a tool.
N/A
Page 17 of 51
Report No.: 17706907 001
IEC 60065
Clause
Requirement + Test
Result - Remark
14.5.3
PTC thermistors comply with IEC 60730-1:2007
No such components.
Verdict
N/A
PTC devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
N/A
14.6
Switches
(see appended table)
P
14.6.1 a)
Separate testing to IEC 61058-1 including:
- 10 000 operations
- Normal pollution suitability
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
An approved switch used and
comply the relevant standard
P
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V0 in annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 610581 subclause 13.1 and has making/breaking action
independent of speed of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 610581 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 61058-1
N/A
Socket outlet current marking correct
N/A
14.7
Safety interlocks
No such component.
Safety interlocks to 2.8 of IEC 60950-1
14.8
Voltage setting devices and the like
N/A
N/A
No such component.
N/A
N/A
Voltage setting device not likely to be changed
accidentally
14.9
Motors
14.9.1
Endurance test on motors
N/A
Motor start test
N/A
Dielectric strength test
N/A
TRF No. IEC60065K
No such component.
N/A
Page 18 of 51
Report No.: 17706907 001
IEC 60065
Clause
Requirement + Test
Result - Remark
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950-1, Annex B
N/A
14.10
Batteries
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
N/A
14.10.2
No possibility of recharging non-rechargeable
batteries
N/A
14.10.3
Recharging currents and times within manufacturers
limits
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11
Optocouplers
No such component.
Approved optocoupler used.
See appended table 14.
N/A
P
a) Comply with 13.6 (jointed insulation) and N.2.1
N/A
b) Comply with IEC 60747-5-5:2007
N/A
P
Alternative to a) and b) optocoupler comply with
13.8
14.12
Verdict
Surge suppression varistors
Certified sources of varistors
are used. For details, see
appended able 14.
Comply with IEC 61051-2
P
P
Not connected between mains and accessible parts
except for earthed parts of permanently connected
apparatus
Not connected to accessible
parts/output circuits.
P
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
Certified sources with suitable
characteristics used.
P
15
Terminals
P
15.1.1
Mains plug, appliance inlet, interconnection couplers MAINS plug and appliance
and mains socket-outlet meet the appropriate
couplers certified according to
standard
relevant standard. See
attached table 14.
P
15.1.2
Overloading of plugs or appliance inlets prevented if
the apparatus has mains socket outlets
N/A
Overloading of internal wiring prevented if the
apparatus has mains socket outlets
N/A
Connectors for antenna, earth, audio, video or data
TRF No. IEC60065K
P
Page 19 of 51
Report No.: 17706907 001
IEC 60065
Clause
Requirement + Test
Result - Remark
No risk of insertion in mains socket-outlets
No risk of insertion into audio- or video- outlets
marked with the symbol of 5.2
Verdict
P
No such connectors.
N/A
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-outlets
N/A
15.2
Provision for protective earthing
N/A
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
N/A
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0,1  at 25 A ................... :
N/A
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
N/A
15.3.1
Adequate terminals for connection of permanent
wiring
N/A
15.3.2
Reliable connection of non-detachable cords
N/A
Not soldered to conductors of a printed circuit board AC inlet used.
N/A
Adequate clearances and creepage distances
between connections should a wire break away
N/A
Wire secured by additional means to the conductor
N/A
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
15.3.4
Soldered conductors wrapped around terminal prior
to soldering or held in place by additional means
N/A
Clamping of conductor and insulation if not soldered
or held by screws
N/A
15.3.5
Terminals allow connection of appropriate crosssectional area of conductors, for the rated current of
the equipment
N/A
15.3.6
Terminals to 15.3.3 have sizes required by table 16
N/A
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
N/A
Terminals designed to avoid conductor slipping out
when tightened or loosened
N/A
Terminals adequately fixed to avoid loosening when
the clamping is tightened or loosened and stress on
internal wiring is avoided
N/A
TRF No. IEC60065K
No screws for such use.
N/A
Page 20 of 51
Report No.: 17706907 001
IEC 60065
Clause
Requirement + Test
Result - Remark
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
N/A
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
N/A
Terminals located and shielded: test with 8 mm
strand
N/A
Not such apparatus.
Verdict
15.4
Devices forming a part of the mains plug
N/A
15.4.1
No undue strain on mains socket-outlets
N/A
15.4.2
Device complies with standard for dimensions of
mains plugs
N/A
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
N/A
16
External flexible cords
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
P
PVC complying with IEC
60227
P
N/A
Non-detachable cords for Class I have green/yellow
core for protective earth
2
16.2
Mains cords conductors have adequate crosssectional area for rated current consumption of the
equipment
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
N/A
b) Flexible cords not complying with 16.1, withstand
bending and mechanical stress (3.2 of IEC 60227-2)
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
N/A
16.5
Adequate strain relief on external flexible cords
16.6
0.75 mm supply cord used for
the apparatus.
AC inlet used.
P
N/A
Not possible to push cord back into equipment
N/A
Strain relief device unlikely to damage flexible cord
N/A
For mains cords of Class I equipment, hazardous
live conductors become taut before earth conductor
N/A
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
N/A
TRF No. IEC60065K
Page 21 of 51
Report No.: 17706907 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet to
IEC 60320-1
N/A
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
N/A
17
Electrical connections and mechanical fixings
P
17.1
Torque test to table 20
P
- screws into metal: 5 times
Screw for fixing stand
(Φ4.0mm) and back cover
(Φ3.0mm).
P
- screws into non-metallic material: 10 times
Screw for fixing back cover
(Φ3.0mm).
P
17.2
Correct introduction into female threads in nonmetallic material
17.3
Cover fixing screws: captive
P
N/A
Non-captive fixing screws: no hazard when replaced
by a screw whose length is 10 times its diameter
P
17.4
No loosening of conductive parts carrying a current
> 0,2 A
P
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
P
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
No such terminals
N/A
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
Cover fixed by screws only.
N/A
17.8
Fixing devices for detachable legs or stands
provided
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
18
Mechanical strength of picture tubes and protection against the effects of
implosion
N/A
18.1
Picture tube separately approved to IEC 61965 .... :
N/A
Picture tube separately approved to 18.2 .............. :
N/A
18.2
Non-intrinsically protected tubes tested to 18.2
N/A
19
Stability and mechanical hazards
TRF No. IEC60065K
N/A
Pull with 2N force.
No disconnection.
P
P
Page 22 of 51
Report No.: 17706907 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Mass of the equipment exceeding 7 kg ................. :
13.0 kg with stand
P
Apparatus intended to be fastened in place –
suitable instructions ................................................ :
o
N/A
19.1
Test on a plane, inclined at 10 to the horizontal
Not overturn
19.2
100 N force applied vertically downwards
19.3
100 N force, or 13% of weight, applied horizontally
to point of least stability
Not exceed 25 kg in weight.
And below 1m in height.
N/A
19.4
Edges or corners not hazardous
No sharp edges and corner
P
19.5
Glass surfaces (exc. laminated) with an area
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
No such parts.
N/A
19.6
Wall or ceiling mountings adequate
No accessories for wall or
ceiling mounting provided.
N/A
20
Resistance to fire
P
20.1
Electrical components and mechanical parts
P
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined in
20.1
N/A
20.1.1
Electrical components meet the requirements of
Clause 14 or 20.1.4
Components are used
correctly within their ratings
and comply with the relevant
flammability requirement. See
appended table 14.
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire
No such internal wiring.
20.1.3
Material of printed circuit boards on which the
All used PCB comply with UL
available power exceeds 15 W at a voltage between approved flammability class of
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
94 V-0. (See table 14).
better to IEC 60707, unless used in a fire enclosure
20.1.4
P
P
N/A
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
Same as above.
P
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
Min. flammability class for
transformer and line choke are
V-0. See appended table 14.
P
Components and parts as above but shielded from a
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
TRF No. IEC60065K
N/A
Page 23 of 51
Report No.: 17706907 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Apparatus with voltages >4kV under normal
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
N/A
20.2
Fire enclosure
N/A
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
20.2.2
Internal fire enclosures with openings not exceeding Not applied
1 mm in width and with openings for wires
completely filled
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
A
Annex A, Additional requirements for apparatus with protection against
splashing water
N/A
A.5
Marking and instructions
N/A
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
N/A
A.10
Insulation requirements
N/A
A.10.2
Splash and humidity treatment
N/A
A.10.2.1
Enclosure provides protection against splashing
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
Annex B, Apparatus to be connected to the TELECOMMUNICATION
NETWORKS
N/A
Complies with IEC 62151 clause 1
N/A
No such high voltage within
apparatus.
No such internal fire enclosure.
No requirements for protection
against splashing water during
intended use.
Not for connection with
telecommunication networks.
N/A
N/A
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
TRF No. IEC60065K
Page 24 of 51
Report No.: 17706907 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Complies with IEC 62151 annex A, B and C
N/A
L
ANNEX L, Additional requirements for electronic flash apparatus for
photographic purposes
N/A
L. 5
Marking and instructions
N/A
L. 5.4
Instructions for battery chargers and Supply
apparatus indicating type or model number of flash
apparatus with which it is to be used
N/A
Instructions for flash apparatus indicating type or
model number of battery chargers or Supply
apparatus with which it is to be used
N/A
L. 7
Heating under normal operating conditions
N/A
L7.1.5 &
L11.2.7
Lithium batteries meet permissible temp rise in
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC
60086-4
N/A
L. 9
Electric shock hazard under normal operating
conditions
N/A
L. 9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
N/A
L.10
Insulation requirements
N/A
L. 10.3.2
High frequency puls ignition
N/A
L. 12
Mechanical strength
N/A
L. 12.1.3
Windows for flash tubes are excluded from steel ball
impact test
N/A
L. 14
Components
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
N/A
L. 20
Resistance to fire
N/A
L. 20.1 c)
Trigger coil for discharge purpose is not considered
to be a POTENTIAL IGNITION SOURCE
N/A
TRF No. IEC60065K
Page 25 of 51
7.1
Report No.: 17706907 001
TABLE: temperature rise measurements:
P
Power consumption in the OFF/Stand-by mode of
the functional switch (W) ......................................... :
Cond.
Un (V)
Hz
In (A)
0W/ 0.51W max.
Pn (W) Uout (V) Pout (W) Operating Condition / Status
Max. normal load with 1/8 non-clipped max. audio output power
1.
220
50
0.64
134.1
--
--
ATV mode
2.
220
50
0.64
134.0
--
--
AV mode
3.
220
50
0.64
134.0
--
--
YPbPr mode
4.
220
50
0.64
134.0
--
--
HDMI mode
5.
198
50
0.71
134.3
--
--
ATV mode
6.
240
50
0.60
133.9
--
--
ATV mode
7.
264
50
0.60
133.6
--
--
ATV mode
Max. normal load with max. non-clipped audio output power
8.
198
50
0.82
156.6
--
--
ATV mode
9.
220
50
0.74
156.2
--
--
ATV mode
10.
240
50
0.68
155.9
--
--
ATV mode
11.
264
50
0.68
155.6
--
--
ATV mode
Loudspeaker impedance (Ω) .................................. :
2*8 Ω
—
Several loudspeaker systems ................................. :
--
--
Marking of loudspeaker terminals ........................... :
--
--
Temperature Rise dT of Part
Test Condition No.
dT (K)
Limit max dT (K)
No 8
No 11
No _-__
Power supply cord
5.8
6.3
--
60
Primary wire after main switch
7.1
6.9
--
60
60
EUT
LCD panel surface (front)
1.6
3.6
--
LCD panel surface (back)
8.0
9.3
--
40
18.0
18.0
--
For reference.
9.4
10.0
--
60
1.6
2.0
--
50
AC inlet(XP802) close to pins
12.6
12.6
--
35(70-35)
L802 winding
17.1
16.2
--
95(130-35)
L812 winding
23.9
21.1
--
95(130-35)
C813(X2)
13.7
13.0
--
50(85-35)
C809 (Y1)
38.1
38.2
--
50(85-35)
C860 (Electrolytic)
22.7
26.1
--
70(105-35)
Winding of T831
53.5
52.7
--
75*(85-10)
Back enclosure above the power
supply(Internal part)
Back enclosure above the power
supply(external part)
Button of main switch
Power supply board
TRF No. IEC60065K
Page 26 of 51
Temperature Rise dT of Part
Report No.: 17706907 001
dT (K)
Limit max dT (K)
Test Condition No.
No 8
No 11
No _-__
Primary Winding of T901
38.6
39.0
--
75*(85-10)
Secondary Winding of T901
33.8
34.5
--
75*(85-10)
75*(85-10)
Winding of T902
27.7
28.7
--
PCB under VB801 and heat sink
34.2
31.9
--
85(120-35)
85(120-35)
PCB under V802 and heat sink
25.0
26.1
--
PCB under VD829 and heat sink
53.5
52.6
--
85(120-35)
PCB under T831
46.3
45.5
--
85(120-35)
N891(photocoupler)
29.2
28.7
--
65(100-35)
Insulation sheet under PSU
21.6
21.9
--
45(80-35)
PCB under main chip
26.3
27.4
--
85(120-35)
PCB under audio amplifier
27.3
28.4
--
85(120-35)
24.7°C
21.0°C
--
--
Mainboard
Ambient
Note(s):
1. Specified maximum ambient temperature for operation is 35 °C.
2. Permitted temperature rises were reduced by 10K for switch mode transformer when measured by
thermocouple.
Winding temperature rise measurements
o
—
o
—
Ambient temperature t1 ( C) ....................... :
Ambient temperature t2 ( C) ....................... :
Temperature rise dT of winding:
dT = (R2 – R1) x (234.5 + t1) – (t2 – t1)
R1
7.2
R1 (Ω)
R2 (Ω)
dT (K)
Limit max (K) Insulation class
TABLE: softening temperature of thermoplastics
Temperature T of part
N/A
T - normal conditions
o
( C)
T - fault conditions
o
( C)
Min T softening
o
( C)
-
-
-
-
Note: Phenolic bobbin material used for transformers and line filters were acceptable without further test.
Primary connector not considered as such part.
10.3
TABLE: insulation resistance measurements
P
R (MΩ)
Required R (MΩ)
Unit: Between parts of opposite polarity directly connected to
the mains poles (with fuse disconnected), (BI)
100
2
Unit: Primary circuits (L/N) to LCD panel (RI)
100
4
Unit: Primary circuits (L/N) to accessible surface (RI)
100
4
Unit: Primary circuits (L/N) to signal connectors (RI)
100
4
T831/T901: Primary windings to secondary windings (RI)
100
4
Insulation resistance R between:
TRF No. IEC60065K
Page 27 of 51
Report No.: 17706907 001
R (MΩ)
Required R (MΩ)
T831: Primary windings/pins and secondary windings/pins to
core and insulation tubing (BI or SI)
100
2
T901: Primary windings/pins and secondary windings/pins to
core (BI or SI)
100
2
T902: Primary windings and core to secondary windings (RI)
100
4
T831: Two layers insulation tape (RI)
100
4
Insulation of primary wire (RI)
100
4
Insulation sheet under power supply board (RI)
100
4
Insulation resistance R between:
Notes: All sources of transformers and insulation sheet were considered in this test.
10.3
TABLE: electric strength measurements
Test voltage applied between:
P
Test voltage (V)
Breakdown
Unit: Between parts of opposite polarity directly connected to
the mains poles (with fuse disconnected), (BI)
2120 (peak)
No
Unit: Primary circuits (L/N) to LCD panel (RI)
4240 (peak)
No
Unit: Primary circuits (L/N) to accessible surface (RI)
4240 (peak)
No
Unit: Primary circuits (L/N) to signal connectors (RI)
4240 (peak)
No
T831/T901: Primary windings to secondary windings (RI)
4240 (peak)
No
T831: Primary windings/pins and secondary windings/pins to
core and insulation tubing (BI or SI)
2487 (peak)
No
T901: Primary windings/pins and secondary windings/pins to
core (BI or SI)
2576 (peak)
No
T902: Primary windings and core to secondary windings (RI)
4240 (peak)
No
T831: Two layers insulation tape (RI)
4240 (peak)
No
Insulation of primary wire (RI)
4240 (peak)
No
Insulation sheet under power supply board (RI)
4240 (peak)
No
Notes: All sources of transformers and insulation sheet were considered in this test.
11.2
TABLE: summary of fault condition tests
Voltage (V) 0,9 or 1,1 times rated voltage ..............:
See below
—
Frequency (Hz) ........................................................:
50
—
22.0-25.0 ºC otherwise specified.
—
o
Ambient temperature ( C) .......................................:
No.
P
Component
TRF No. IEC60065K
Fault
dT (K) / Component Other results
(include description and test duration)
Page 28 of 51
No.
1.
Component
Ventilation
Fault
Report No.: 17706907 001
dT (K) / Component Other results
(include description and test duration)
Blocked
T831: 53.9K
T901: 47.6K
T902: 38.3K
PCB under VB801:
38.6K
PCB under VD829:
56.5K
N891: 37.0K
LCD panel surface:
24.8K
Back enclosure:
19.2K
Button of main
switch: 2.4K
o
Ambient: 22.7 C
Input voltage: 198V
Duration: 60 minutes
Limit dT (K)
140(150-10)
140(150-10)
140(150-10)
110
110
65
65
65
65
--
2.
One speaker
s-c
--
Input voltage: 264V
Input: 130.8W;
Both speakers did not work. The other parts
worked as normal. No hazards.
Duration: 10 minutes
3.
USB output
(mainboard)
s-c
--
Input voltage: 264V
Input: 150.8W
The EUT worked normally except for USB
port. No hazards.
Duration: 10 minutes
4.
USB output
(mainboard)
o-l
T831: 56.3 K
T903: 38.3K
T902: 28.1K
o
Ambient: 23.8 C
Input: 198V
Duration: 60 minutes
Input: 152.0W
Normal operation until overload to 3.5A. No
breakdown, no hazards.
Limit dT (K):
140(150-10)
140(150-10)
140(150-10)
--
5.
C860
s-c
--
Input voltage: 264V
No input.
Main fuse broken immediately. Then the EUT
shut down.
No hazards.
Duration: <1s
6.
VB801, Input
to output
s-c
--
Input voltage: 264V
No input.
Main fuse broken immediately. Then the EUT
shut down.
No hazards.
Duration: <1s
TRF No. IEC60065K
Page 29 of 51
No.
Component
Fault
Report No.: 17706907 001
dT (K) / Component Other results
(include description and test duration)
7.
12V output
(C862)
s-c
--
Input voltage: 264V
Input: 0.3 –17.0W
The EUT protected immediately. The input
changed in a range. No picture/sound signal
output. No hazards.
Duration: 10 minutes
8.
16V output
(C868)
s-c
--
Input voltage: 264V
Input: 0.3 –17.0W
The EUT protected immediately. The input
changed in a range. No picture/sound signal
output. No hazards.
Duration: 10 minutes
9.
V807, Pin 1-2
s-c
--
Input voltage: 264V
Input: 0.4W
R818 broken. Then the EUT shut down. No
hazards. Repeat the test 2 times with the
same results.
Duration: 10 minutes
10.
V807, Pin 1-3
s-c
--
Input voltage: 264V
Input: 0.2W
The EUT protected immediately. No
picture/sound signal output. No hazards.
Duration: 10 minutes
11.
V807, Pin 2-3
s-c
--
Input voltage: 264V
Input: 0.4W
R818 broken. Then EUT shut down. No
hazards. Repeat the test 2 times with the
same result.
Duration: 10 minutes
12.
T831,
Pin1-3
s-c
--
Input voltage: 264V
Input: 0.2 – 13.9W
The EUT self-protected immediately. The
input changed in certain range.
No picture/sound signal output.
Duration: 10 minutes
13.
T831,
Pin5-6
s-c
--
Input voltage: 264V
Input: 0.2 – 13.9W
The EUT self-protected immediately. The
input changed in certain range.
No picture/sound signal output.
Duration: 10 minutes
14.
T831,
Pin7-11
s-c
T831:102K
Ambient: 22.0℃
TRF No. IEC60065K
Input voltage: 264V
Input: 0.2 – 139.5W
The EUT self-restart circularly. No hazards.
Duration: 60 minutes
Page 30 of 51
No.
Component
Fault
Report No.: 17706907 001
dT (K) / Component Other results
(include description and test duration)
15.
T831,
Pin8-9/10
s-c
--
Input voltage: 264V
Input: 0.2 – 13.9W
The EUT self-protected immediately. The
input changed in certain range.
No picture/sound signal output.
Duration: 10 minutes
16.
N891, Primary s-c
pins
--
Input voltage: 264V
Input: 0.4W
The EUT self-protected immediately.
No picture/sound signal output. No hazards.
Duration: 30 minutes
17.
N891,
Secondary
pins
s-c
--
Input voltage: 264V
Input: 0.4W
The EUT self-protected immediately.
No picture/sound signal output. No hazards.
Duration: 30 minutes
18.
N834, pin 8-2
s-c
--
Input voltage: 264V
Input: 0.3W
The EUT self-protected immediately.
No picture/sound signal output. No hazards.
Duration: 10 minutes
19.
V901,
Pin 1-2
s-c
--
Input voltage: 264V
No input.
Main fuse broken immediately. Then the EUT
shut down.
No hazards.
Duration: <1s
20.
V901,
Pin 1-3
s-c
--
Input voltage: 264V
Input: 35.2W
The EUT had only sound signal output, no
picture signal output. No hazards.
Duration: 30 minutes
21.
V901,
Pin 2-3
s-c
--
Input voltage: 264V
No input.
Main fuse broken immediately. Then the EUT
shut down.
No hazards.
Duration: <1s
22.
T901, Pin 3-6
s-c
--
Input voltage: 264V
Input: 35.4W
The EUT had only sound signal output, no
picture signal output. No hazards.
Duration: 10 minutes
TRF No. IEC60065K
Page 31 of 51
No.
Component
Fault
Report No.: 17706907 001
dT (K) / Component Other results
(include description and test duration)
23.
T901, Pin 1012
s-c
--
Input voltage: 264V
Input: 36.0W
The EUT had only sound signal output, no
picture signal output. No hazards.
Duration: 10 minutes
24.
T902,
Pin 1-5
s-c
--
Input voltage: 264V
Input: 35.8W
The EUT had only sound signal output, no
picture signal output. No hazards.
Duration: 10 minutes
25.
T902,
Pin 6-7
s-c
--
Input voltage: 264V
Input: 35.6W
The EUT had only sound signal output, no
picture signal output. No hazards.
Duration: 10 minutes
26.
T902,
Pin 10-9
s-c
--
Input voltage: 264V
Input: 35.4W
The EUT had only sound signal output, no
picture signal output. No hazards.
Duration: 10 minutes
27.
XP901 output s-c
(for LED
backlight) L1+
to L1-
--
Input voltage: 264V
Input: 35.4W
The EUT had only sound signal output, no
picture signal output. No hazards.
Duration: 10 minutes
—
Winding temperature rise measurements
o
Ambient temperature t1 ( C) .................................. :
—
o
—
Ambient temperature t2 ( C) .................................. :
Supplementary information: In fault column, where s-c=short circuit and o-l=over load.
13.2
—
TABLE: working voltage measurement
Location
RMS Voltage (V)
Peak Voltage (V)
pin3 - pin8
204
384
pin6 - pin8
175
364
pin3 - pin10
147
360
pin6 - pin10
193
524
pin3 - pin12
261
556
pin6 - pin 12
172
492
pin1 to pin 7/8
307
496
pin3 to pin 7/8
297
476
pin5 to pin 7/8
171
364
pin6 to pin 7/8
169
352
Comments
Transformer T901
Transformer T831
TRF No. IEC60065K
Max. Vpeak&Vrms
Page 32 of 51
Report No.: 17706907 001
pin1 to pin 9/10
314
516
pin3 to pin 9/10
297
404
pin5 to pin 9/10
169
352
pin6 to pin 9/10
169
412
pin1 to pin 11/12
305
484
pin3 to pin 11/12
297
492
pin5 to pin 11/12
172
380
pin6 to pin 11/12
170
356
pin1 to pin 6
202
380
pin1 to pin 7
208
392
pin1 to pin 9
173
356
pin1 to pin 10
172
368
pin5 to pin 6
203
376
pin5 to pin 7
206
384
pin5 to pin 9
174
360
pin5 to pin 10
173
368
pin7 to GND
170
352
pin9 to GND
205
384
C909 pin+ to pin-
164
360
N891 pin 1-4
161
336
Max. Vpeak&Vrms
Transformer T902
Max. Vpeak&Vrms
Other components
Supplementary information: 240V supplied.
13.3 & 13.4
TABLES: Clearances and Creepage distances
Rated supply voltage:
240V a.c.
Pollution degree .. :
P
2
Material Group .... :
IIIb
2 N force on internal parts applied:
--
Yes
30 N force on outside of conductive enclosure applied:
--
N/A
Location
Working Voltage
Clearance (mm)
Creepage (mm)
V rms
V peak
Min
Actual
Min
Actual
L/N before fuse (BI)
250*
420*
2.0
3.1
2.5
3.1
Trace between fuse (BI)
250*
420*
2.0
3.0
2.5
3.0
Primary to secondary (RI)
See below
See below
- Under C803, C804
250*
420*
4.0
6.0
5.0
6.0
- Under C809
250*
420*
4.0
6.2
5.0
6.2
- Under N891, N881
250*
420*
4.0
6.2
5.0
6.2
- Under T831 (Trace of N891 primary to
secondary)
250*
420*
4.0
6.2
5.0
6.2
- Under T901 (Trace of T902 pin 9 to GND)
250*
420*
4.0
6.2
5.0
6.2
- Under T902
250*
420*
4.0
7.6
5.0
7.6
Circuits conductively connected to the mains (use Tables 8, 9 and 11): see note below.
TRF No. IEC60065K
Page 33 of 51
Location
Report No.: 17706907 001
Working Voltage
Clearance (mm)
Creepage (mm)
V rms
Min
Min
V peak
Actual
Actual
Notes:
1. For clearance and creepage did not describe above are far larger than limit above. "Min" = minimum
required. "Actual = Actual dimensions measured.
2. Data with * means the measured data not more than this data.
3. 2N force applied on relevant components during the distance test.
4. Component fixed by glue on the PCB: RV801, RT801, C860, C862, C865 etc.
5. For clearance and creepage of transformers T831, T901 and T902 please refer to the table 14.3.3 and
14.3.4.
14
TABLE: list of critical components and materials
Component
Manufacturer/
trademark
Power supply
board
Value / rating
Standard
Approval/
Reference
Hisense Electric HLL-4855WF
Co., Ltd.
Input: AC 100240V, 50/60Hz,
3A Max;
output: DC12V,
3A; DC16V,
1.5A; DC200V
400mA.
IEC/EN 60065
Tested with
equipment
-PCB
Changzhou
Aohong
Electronics Co.,
Ltd
V-0, 1.5mm Min. UL 94
UL 796
Thick, 130C.
-(Alternative)
Interchangeable Interchangeable V-0, 1.5mm Min. UL 94
UL 796
Thick, 120C
min.
-AC inlet
(XP802)
Zhang Jiagang
Huajie
Electronic Co.,
Ltd
SA-2S-127; SA- 250V AC, 2.5A
2S-129; SA-2S- 70C, standard
165
sheet C8
IEC/EN 60320-1 TUV
R 50304415
-(Alternative)
Zhang Jiagang
Huajie
Electronic Co.,
Ltd
SA-2S C; SA-2S 250V AC, 2.5A
D; SA-2S D1;
70C, standard
SA-2S E; SA-2S sheet C8
C-2
IEC/EN 60320-1 TUV
R 50187984
-(Alternative)
Zhang Jiagang
Huajie
Electronic Co.,
Ltd
SA-2S H; SA-2S 250V AC, 2.5A
L; SA-2S J; SA- 70C, standard
2S K; SA-2S M; sheet C8
SA-2S N
IEC/EN 60320-1 TUV
R 50256890
-(Alternative)
Zhe Jiang Bei Er ST-A03-001
Jia Electronic
Co., Ltd.
250V AC, 2.5A
70C, standard
sheet C8
IEC/EN 60320-1 NEMKO
P04203029/A1
-(Alternative)
Zhe Jiang Bei Er ST-A03-002
Jia Electronic
ST-A03-004
Co., Ltd.
ST-A03-005
250V AC, 2.5A
70C, standard
sheet C8
IEC/EN 60320-1 ENEC ENEC00636
VDE 40014833
-(Alternative)
TECX-UNIONS
ELECTRONIC
CO., Ltd
SO-222
250V AC, 2.5A
70C, standard
sheet C8
IEC/EN 60320-1 VDE 40020337
-Primary
connector
(XP803)
Shanghai Hua
Yi Group Hua
Yuan Chemical
Industry Co Ltd
PA66 FR-102
V-0
UL 94
IEC 60065
TRF No. IEC60065K
Type/model
P
AOH-2
UL E303981
UL
UL E176060 &
Tested with
equipment
Page 34 of 51
Component
Manufacturer/
trademark
-(Alternative)
Standard
Approval/
Reference
Interchangeable Interchangeable V-0
UL 94
UL
-Fuse (F801)
Littelfuse Inc.
382
T6.3AL,
AC 250V
IEC/EN 60127-1 VDE 40018250
IEC/EN 60127-3
-(Alternative)
XC Electronics
(Shenzhen)
Corp. Ltd.
5TR
T6.3AL,
AC 250V
IEC/EN 60127-1 VDE 40019787
IEC/EN 60127-3
-(Alternative)
Conquer
Electronics Co.,
Ltd.
MET
T6.3AL,
AC 250V
IEC/EN 60127-1 VDE 40017155
IEC/EN 60127-3
-(Alternative)
Suzhou Walter 2000
Electric Co., Ltd
T6.3AL,
AC 250V
IEC/EN 60127-1 VDE 40018787
IEC/EN 60127-3
-VDR (RV801)
Thinking
Electronic
lndustrial Co.,
Ltd.
TVR10621-V
620V, fulfil with
IEC 60950-1
Annex Q
IEC/EN 61051-1 VDE 005944
Thinking
Electronic
lndustrial Co.,
Ltd.
TVR10621-D
620V, fulfil with
IEC 60950-1
Annex Q
IEC/EN 61051-1 VDE 40021243
EPCOS OHG
S10KV621E2K1 620V, fulfil with
IEC 60950-1
Annex Q
IEC/EN 61051-1 VDE 40027582
Shaanxi
MYG20G10K62 620V, fulfil IEC
Huaxing
1
60950-1 Annex
electronic group
Q
Co., Ltd.
IEC/EN 61051-1 VDE 40018747
-Filter (L801,
L802)
Jiangsu Lettall
Electronic Co.,
Ltd.
LCL-3505-HF
130C
IEC/EN 60065
Tested with
equipment
-(Alternative)
Haining
Lianfeng
Dongjin
Electronic Co.,
Ltd.
LCL-010-F
130C
IEC/EN 60065
Tested with
equipment
-(Alternative)
Dezhou Sanhe LCL-35-016
Electric Co., Ltd.
130C
IEC/EN 60065
Tested with
equipment
-(Alternative)
Weihai
Dongxing
Electronics Co.,
Ltd.
LCH-10020-01
130C
IEC/EN 60065
Tested with
equipment
-(Alternative)
Shandong
Zhongrui
Electronics Co.,
Ltd.
ZRI-10020-19
130C
IEC/EN 60065
Tested with
equipment
-(Alternative)
Jiangsu Huaxing LCL-2505D-103 130C
Electric Co., Ltd
IEC/EN 60065
Tested with
equipment
-- bobbin
Changchun
Plastics Co.,
Ltd.
Phenolic,
150C, V-0
UL 94
UL E59481
-- (Alternative)
Interchangeable Interchangeable Phenolic,
150C; V-0
UL 94
UL
-(Alternative)
-(Alternative)
-(Alternative)
TRF No. IEC60065K
Type/model
T375J
Value / rating
Report No.: 17706907 001
IEC/EN 61051-2
IEC/EN 61051-2
IEC/EN 61051-2
IEC/EN 61051-2
Page 35 of 51
Component
Manufacturer/
trademark
-NTC (RT801)
Standard
Approval/
Reference
Interchangeable Interchangeable 5Ω at 25C
UL 1434
UL
-Bleeder
resistor (R802,
R804, R809
R970, R971
R972)
Interchangeable Interchangeable 1MΩ, 1/4W
IEC/EN 60065
Tested with
equipment
-X2 Capacitor
( C813,C846)
Xiamen
Faratronic Co.,
Ltd.
MKP62
0.47μFmax.,
IEC/EN 60384AC 275V,110C 14
VDE
40000358
-(Alternative)
Xiamen
Faratronic Co.,
Ltd.
MKP61
0.47μF max.,
IEC/EN 60384AC 275V,100C 14
VDE
40007424
-(Alternative)
Nanjing Tengen MKP
Rongguangda
Electronics
(Group) Co.,
Ltd.
0.47μF max.,
IEC/EN 60384AC 275V, 100C 14
VDE 40028680
-(Alternative)
Uitra Tech Xiphi HQX
Enterprise Co.,
Ltd.
0.47μF max.,
IEC/EN 60384AC 275V, 100C 14
VDE 40024534
-(Alternative)
Guangdong
MKP-X2
Fengming
Electronic Tech.
Co., Ltd.
0.47μF max.,
AC 275V, 85C
IEC/EN 6038414
VDE 40025702
-Electrolytic
capacitor
(C860, C865)
Interchangeable Interchangeable 68μF, 450V
min., 105C
IEC/EN 60065
Tested with
equipment
-Y1 Capacitor
(C803, C804,
C809)
Anshan
Electronic
Ceramic Co.,
Ltd.
CT7
C803=C804=
470pF max,
C809= 1000pF
max., AC250V
min., 85C
IEC/EN 6038414
VDE 40011817
-(Alternative)
TDK Xiamen
Co., Ltd.
CD
C803=C804=
470pF max,
C809=1000pF
max., AC250V
min., 85C
IEC/EN 6038414
VDE 124321
-(Alternative)
Yinan Don’s
CT81
Electronic
Component Co.,
Ltd.
C803=C804=
470pF max,
C809=1000pF
max., AC250V
min., 125C
IEC/EN 6038414
VDE 135256
-(Alternative)
Guangdong
F
South
Hongming
Electronic
Science and
Technology Co.,
Ltd.
C803=C804=
470pF max,
C809=1000pF
max., AC250V
min., 125C
IEC/EN 6038414
VDE 118357
TRF No. IEC60065K
Type/model
Value / rating
Report No.: 17706907 001
Page 36 of 51
Report No.: 17706907 001
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference
-(Alternative)
Murata
Manufacturing
Co., Ltd.
KX
C803=C804=
470pF max,
C809=1000pF
max., AC250V
min., 125C
IEC/EN 6038414
VDE 40002831
-(Alternative)
Kunshan
Wansheng
Electronics Co.,
Ltd.
CT7
C803=C804=
470pF max.,
C809=1000pF
max., AC250V
min., 125C
IEC/EN 6038414
VDE 40012143
-Transformer
(T831)
Jiangsu Lettall
Electronic Co.,
Ltd.
BK-10-05HI
Class B,refer to IEC/EN 60065
table 14.3.3&
IEC 60085
14.3.4 for details
Tested with
equipment
-(Alternative)
Dezhou Sanhe SANHE-35-208
Electric Co., Ltd.
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-(Alternative)
Haining
Lianfeng
Dongjin
Electronic Co.,
Ltd.
BCK-70-05HI
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-(Alternative)
Weihai
Dongxing
Electronics Co.,
Ltd.
BCK-EFD-3333
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-(Alternative)
Yueqing Jingmi
Electron
Electronic Co.,
Ltd.
XW40EFD2B19H015
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-- Windings
Interchangeable Interchangeable 130C
UL 1446
UL
-- Bobbin
Sumitomo
Bakelite Co.,
Ltd.
PM-9820
Phenolic,
150C; V-0
UL 94
UL E41429
(Alternative)
Chang Chun
Plastics Co.,
Ltd.
T375J
Phenolic,
150C; V-0
UL 94
UL E59481
(Alternative)
Interchangeable Interchangeable Phenolic,
150C; V-0
UL 94
UL
--Insulation tape Yahua Pressure CT
Sensitive Glue
Co., Ltd.
UL 510
130C, flame
retardant, CTI
400 min,
material group II
min.
UL E165111
--Margin tape
Yahua Pressure WF
Sensitive Glue
Co., Ltd.
UL 510
130C, flame
retardant, CTI
400 min.
material group II
min.
UL E165111
--Tubing
Interchangeable Interchangeable 200C, 600V,
VW-1
TRF No. IEC60065K
UL 224
UL
Page 37 of 51
Type/model
Component
Manufacturer/
trademark
-Transformer
(T901)
Haining lianfeng BCK-70-H012
Dongjin
Electronic Co.,
Ltd.
Class B,refer to IEC/EN 60065
table 14.3.3&
IEC 60085
14.3.4 for details
Tested with
equipment
-(Alternative)
Weihai
Dongxing
Electronics Co.,
Ltd.
BCK-EFD-3538
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-(Alternative)
Jiangsu Lettall
Electronics Co.,
Ltd.
BK-20-12HE
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-(Alternative)
Yueqing Jingmi XW40EFD2Electron
A34H012
Electronic Co.,
Ltd.
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-(Alternative)
Dezhou Sanhe SANHE-35-240
Electric Co., Ltd.
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-- Windings
Interchangeable Interchangeable 130C
UL1446
UL
-- Bobbin
Sumitomo
Bakelite Co.,
Ltd.
PM9820
Phenolic,
150C; V-0
UL 94
UL E41429
(Alternative)
Chang Chun
Plastics Co.,
Ltd.
T375J
Phenolic,
150C; V-0
UL 94
UL E59481
(Alternative)
Interchangeable Interchangeable Phenolic,
150C; V-0
UL 94
UL
130C, flame
retardant,
UL 510
UL E165111
--Insulating tape Interchangeable Interchangeable 130C, flame
retardant
UL 510
UL
--Insulation tape Yahua Pressure CT
Sensitive Glue
Co., Ltd.
Value / rating
Report No.: 17706907 001
Standard
Approval/
Reference
-Transformer
(T902)
Weihai
Dongxing
Electronics Co.,
Ltd.
BCK-25-1605
Class B,refer to IEC/EN 60065
table 14.3.3&
IEC 60085
14.3.4 for details
Tested with
equipment
-(Alternative)
Yueqing Jingmi
Electron
Electronic Co.,
Ltd.
XW2025EPCB05H003
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-(Alternative)
Jiangsu Lettall
Electronics Co.,
Ltd.
BK-10-05YG
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-(Alternative)
Haining
Lianfeng
Dongjin
Electronic Co.,
Ltd.
BCK-20-1605
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-(Alternative)
Dezhou Sanhe SANHE-19-065
Electric Co. Ltd.
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
--Pri. Windings
Interchangeable Interchangeable 130C
UL1446
UL
TRF No. IEC60065K
Page 38 of 51
Report No.: 17706907 001
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference
--Sec. windings
FURUKAWA
ELECTRIC CO
LTD
TEX-E
130C, triple
insulation wire
UL 2353
UL E206440
IEC/EN 60950-1 VDE 006735
IEC/EN 60065
-(Alternative)
Shanghai Lucy
Trade Co., Ltd.
TIW-B
130C, triple
insulation wire
UL 2353
UL E305883
IEC/EN 60950-1 VDE 40023686
IEC/EN 60065
--Bobbin
Interchangeable Interchangeable Phenolic,
150C; V-0
UL 94
UL
--Insulating tape Interchangeable Interchangeable 130C, flame
retardant
UL 510
UL
--Tubing
Interchangeable Interchangeable 200C, 600V,
VW-1
UL 224
UL
-Photocoupler
(N881, N891)
Everlight
Electronics Co.,
Ltd.
Int.=6.0mm,
Ext.=7.7mm,
dti. ≥0.5mm,
110C
IEC/EN 60065
DEMKO DIEC/EN 60950-1 00764-A1
-(Alternative)
VISHAY
VO617A-3
Semiconductour
GmBH
Int.=5.8mm,
Ext.=7.0mm,
dti. ≥0.6mm,
100C
IEC/EN 60065
FIMKO NCS/FI
IEC/EN 60950-1 26764 A1
-(Alternative)
Lite-On
Technology
Corporation
LTV-817
Int.=5.2mm,
Ext.=7.8mm,
dti. ≥0.8mm,
110C
IEC/EN 60065
Intertek
IEC/EN 60950-1 1312430
MTK5657
--
--
EL817
Main signal board
Main IC
MediaTek.Inc
--
PCB
Interchangeable Interchangeable V-0, 1.6mm min. UL 94
UL 796
thick, 120C
min.
UL
Hisense Electric HD500DU-B53
Co., Ltd.
Tested with
equipment
Others
LCD panel
50 inch TFT
IEC/EN 60065
LCD with LED
backlight. The
max. power
consumption for
signal part is
30.6W
Insulation sheet Suzhou Omay
under power
Optical
supply board
Materials Co.,
Ltd.
SE42B
PC, 0.5mm
thick, V-0, 80C
UL 94
UL E249605
(Alternative)
Chengdu
Kanglongxin
Plastics Co.,
Ltd.
KLX FRPC870B or
KLX FRPC1880B
PC, 0.5mm
thick, V-0, 80C
UL 94
UL E315185
Main switch
Zhangjiagang
HF-606(TV)-P
Huafeng
HF-606(TV)-S
Electronic
Connector &
Component Co.,
Ltd.
Rocker switch,
TV-5, 8A/128A
AC 250V,
T85/55, 10E3,
Level 3
IEC/EN 61058-1 VDE 40008136
TUV
R50120515
TRF No. IEC60065K
Page 39 of 51
Report No.: 17706907 001
Component
Manufacturer/
trademark
Type/model
Value / rating
(Alternative)
Zhangjiagang
Huajie
Electronic
PS8
Rocker switch,
IEC/EN61058-1
6(4)A, AC 250V,
5E4, T85/55,
Level 3
(Alternative)
Zhejiang
Zhongxun
Electronics Co.,
Ltd
KCD1-104-2
10(6)A or 6/12A IEC/EN 61058-1 TUV
AC 250V, 1E4,
R50264134
T55
(Alternative)
Zhejiang LECI
Electronics Co.,
Ltd.
RS601D
6(4)A, AC 250V, IEC/EN 61058-1 VDE 40017430
1E4, T55, Level
TUV
3; 8A/128A, AC
R50210040
250V, 1E4, T55.
(Alternative)
ZheJiang
Beierjia
Electronics Co.,
Ltd
PS8A-11
Rocker switch,
12(4)A, AC
250V, 10E3,
T55
IEC/EN 61058-1 VDE 40024550
Primary wire
Interchangeable AWM1672
VW-1, 105C,
300V, 20AWG,
reinforced
insulation
UL 758
UL
Insulating cap
on main switch
Interchangeable Interchangeable PC, 0.7mm
thick, V-0
UL 94
UL
Main Plug
Shanghai
Yusheng
Enterprise
Development
Co., Ltd.
AC 250V,16A
VDE 0620-1
VDE 123226
(Alternative)
I-Sheng Electric SP-026A
Wire & Cable
Co., Ltd.
AC 250V,16A
VDE 0620-1
VDE 40016019
(Alternative)
Shenzhen
XK-36
Xiekang Electric
Co., Ltd.
AC 250V,16A
VDE 0620-1
VDE 40026243
(Alternative)
Interchangeable Interchangeable AC 250V,16A
VDE 0620-1
VDE
(Alternative)
Shenzhen
XK-01
Xiekang Electric
Co., Ltd.
AC 250V, 2.5A
VDE 0620-101
EN 50075
VDE 40009009
(Alternative)
I-Sheng Electric SP-021A
Wire & Cable
Co., Ltd.
AC 250V, 2.5A
VDE 0620-101
EN 50075
VDE 40013649
(Alternative)
Shanghai
Yusheng
Enterprise
Development
Co., Ltd.
YS-3
AC 250V, 2.5A
VDE 0620-101
EN 50075
VDE 112875
(Alternative)
Longkou Jin
Sheng
Electronics
Products Co.,
Ltd.
LFD-215
AC 250V, 2.5A
VDE 0620-101
EN 50075
VDE 40027592
TRF No. IEC60065K
YS-2
Standard
Approval/
Reference
VDE 40027662
TUV
R50191561
Page 40 of 51
Component
Manufacturer/
trademark
(Alternative)
Value / rating
Standard
Approval/
Reference
Zhejiang
YP205
Yuehua
Telecommunicat
ion Co., Ltd.
AC 250V, 2.5A
VDE 0620-101
EN 50075
VDE 40013170
(Alternative)
Taiwan Line Tek LP-21
Electronic Co.,
Ltd.
AC 250V, 2.5A
VDE 0620-101
EN 50075
VDE 40009324
(Alternative)
Interchangeable Interchangeable AC 250V, 2.5A
VDE 0620-101
EN 50075
VDE or TUV
(Alternative)
Shenzhen
XK-28
Xiekang Electric
Co., Ltd.
AC 250V, 13A
BS 1363-1
Intertek
ASTA 972
(Alternative)
Shanghai
Yusheng
Enterprise
Development
Co., Ltd.
AC 250V, 13A
BS 1363-1
BSI KM68299
(Alternative)
Taiwan Line Tek LP-61L
Electronic Co.,
Ltd.
AC 250V, 13A
BS 1363-1
BSI KM55112
(Alternative)
Zhejiang
YP317
Yuehua
Telecommunicat
ion Co., Ltd.
AC 250V, 13A
BS 1363-1
BSI KM512007
(Alternative)
Interchangeable Interchangeable AC 250V, 13A
or AC 250V 5A
BS 1363-1
BSI, Intertek or
TUV
Power Cord
Shanghai
Yusheng
Enterprise
Development
Co., Ltd.
H03VVH2-F
H05VVH2-F
2x0.75mm
2
IEC 60227
VDE 0281-5
VDE 112929
(Alternative)
Zhejiang
H03VVH2-F
Yuehua
Telecommunicat
ion Co., Ltd.
2x0.75mm
2
IEC 60227
VDE 0281-5
VDE 130596
(Alternative)
I-Sheng Electric H03VVH2-F
Wire & Cable
Co., Ltd.
2x0.75mm²
VDE 0281-5
IEC 60227
VDE 40006070
(Alternative)
Mainland
Electric
Wire & Cable
Co., Ltd.
H03VVH2-F
2x0.75mm
2
IEC 60227
VDE 0281-5
VDE 40010355
(Alternative)
Shenzhen
H03VVH2-F
Xiekang Electric
Co., Ltd.
2x0.75mm
2
IEC 60227
VDE 0281-5
VDE 40029225
(Alternative)
Interchangeable H03VVH2-F
H05VVH2-F
2x0.75mm
2
IEC 60227 or
VDE 0281-5
VDE or
equivalent
AC connector
I-Sheng Electric IS-037
Wire & Cable
Co., Ltd.
AC 250V, 2.5A,
standard sheet
C7
TRF No. IEC60065K
Type/model
Report No.: 17706907 001
YS-55
IEC/EN 60320-1 VDE 40026164
Page 41 of 51
Component
Manufacturer/
trademark
(Alternative)
Type/model
Report No.: 17706907 001
Value / rating
Standard
Approval/
Reference
I-Sheng Electric IS-033
Wire & Cable
Co., Ltd.
AC 250V, 2.5A,
standard sheet
C7
IEC/EN 60320-1 VDE 40026860
(Alternative)
Taiwan Linetek
Electronic Co.,
Ltd.
LS-7
AC 250V, 2.5A,
standard sheet
C7
IEC/EN 60320-1 VDE 40028570
(Alternative)
Shanghai
Yusheng
Enterprise
Development
Co., Ltd
YS-65
AC 250V, 2.5A,
standard sheet
C7
IEC/EN 60320-1 VDE 40020913
(Alternative)
Weihai Honglin
Electronic Co.,
Ltd
HL-028
AC 250V, 2.5A,
standard sheet
C7
IEC/EN 60320-1 VDE 40039499
(Alternative)
Weihai Honglin
Electronic Co.,
Ltd
HL-028S
AC 250V, 2.5A,
standard sheet
C7
IEC/EN 60320-1 VDE 40029835
(Alternative)
Shenzhen
XK-05
Xiekang Electric
Co., Ltd.
AC 250V, 2.5A,
standard sheet
C7
IEC/EN 60320-1 VDE 40018650
Rear Enclosure
Qingdao Guoen PS3001ZScience &
600A(b)
Technology Co.,
Ltd.
V-0, Min. 2.5mm UL 94
thick.
UL E330547
(Alternative)
Huizhou Wote
Advanced
Materials Co.,
Ltd.
51(x)FR
V-0, Min. 2.5mm UL 94
thick.
UL E310240
(Alternative)
Orinko (Hefei)
Advanced
Plastic Co Ltd
HIPS-2230
V-0, Min. 2.5mm UL 94
thick.
UL E328304
Front enclosure Asia Int’i
AIEA2200FR(#) V-0
Enterprise
(Hongkong) Co.,
Ltd
UL 94
UL E252275
Alternative
SDI CHEMICAL LS-1159(R)
CO LTD
V-1 min.
UL 94
UL E115797
Alternative
Huizhou Wote
Advanced
Materials Co.,
Ltd
2000
V-0
UL 94
UL E310240
Alternative
Orinko (Hefei)
Advanced
Plastic Co., Ltd
PC/ABS-551X
V-0
UL 94
UL E328304
Stand
SAMYANG
Corporation
201NHF
V-0
UL 94
UL E121254
Alternative
LG Chem
LUPOY GN5001RF(T)
(Tianjin)
Engineering
Plastics Co., Ltd
V-0
UL 94
UL E302314
TRF No. IEC60065K
Page 42 of 51
Component
Manufacturer/
trademark
Type/model
Alternative
SDI CHEMICAL NH-1017(p)
CO LTD
Report No.: 17706907 001
Value / rating
Standard
Approval/
Reference
V-0
UL 94
UL E115797
Notes:
1) An asterisk indicates a mark which assures the agreed level of surveillance
2) The supply cord is applicable with the main plug only which was evaluated during certification of the main
plug.
3) All sources of enclosure material were considered for all test items in clause 12.
4) For interchangeable sources, the validity of the certificates shall be checked during national approval.
Remarks
Supplementary test results for subclause 9.1.1:
Measured between:
Uoc (V)
U1 (V)
Limit U1
U2 (V)
Limit U2
L/N and Signal
connectors
--
1.02
35.0V
0.10
0.35V
L/N and LCD panel/
enclosure
--
0.72
35.0V
0.02
0.35V
Notes: Input voltage 264V, 50Hz
Supplementary test results for subclause 11.1:
Measured between:
Fault conditions
L/N and Signal
connectors
Fuse broken
L/N and LCD panel/
enclosure
Fuse broken
L/N and Signal
connectors
L/N and LCD panel/
enclosure
Uoc (V)
U1 (V)
Limit U1
U2 (V)
Limit U2
--
0.968
70V
0.172
1.4V
--
0.662
35V
0.024
0.35V
XP901 output
L1+ to GND, sc
--
0.849
70V
0.276
1.4V
XP901 output
L1+ to GND, sc
--
0.470
35V
0.62
0.35V
Notes: Input voltage 264V, 50Hz
14.3.3 and
14.3.4
P
Safety isolation transformer
Construction details: See below
Transformer part name: T831
Manufacturer:
(see appended table 14)
Type:
(see appended table 14)
Recurring peak voltage
516Vpk
Required clearance for reinforced insulation
(from table 8 and 9)
4.4mm (BI=SI=2.2mm)
Effective voltage rms
314Vrms
Required creepage distance for reinforced insulation
(from table 11)
6.8mm (BI=SI=3.4mm)
Measured min. creepage distance
Location
TRF No. IEC60065K
inside (mm)
outside (mm)
Page 43 of 51
Report No.: 17706907 001
Primary to Secondary (RI)
7.5
7.2
Primary to core (BI)
7.5
3.6
Secondary to core (SI)
7.5
3.6
inside (mm)
outside (mm)
Primary to Secondary (RI)
7.5
7.2
Primary to core (BI)
7.5
3.6
Secondary to core (SI)
7.5
3.6
Measured min. clearances
Location
Remark:
1. Core of T831 is considered as Inter-Medium part. Three layers insulation tapes wrapped outside
the core.
2. Concentric windings on phenolic bobbin, there are three layers of insulation tapes between
primary windings and secondary windings.
3. Min 7.5 mm width margin tape used inside on primary side and Min 5.5 mm width margin tape
used on secondary side. Insulation tubing used at the end of secondary winding. The bobbin
between the pins to the core is min. 0.8mm.
4. The primary and secondary pins molded to bobbin and directly soldered to PCB.
Construction:
TRF No. IEC60065K
Page 44 of 51
4. WINDING CONSTRUCTION and Dismantling
TRF No. IEC60065K
Report No.: 17706907 001
Page 45 of 51
Report No.: 17706907 001
Notes:
The unit of the dimension is “mm”.
All transformers have the same construction. They are identical except for manufacturer and model name.
Pin numbers
Hazards winding
1-2-3, 5-6
Non-hazards winding
7-11, 8-9/10
Bobbin
Material
1. Sumitomo Chemical Co., Ltd. Type
No. PM9820, Phenolic, 150C;
2. Chang Chun Plastic Co., Ltd. Type No.
T375J, Phenolic Molding Compound,
150C.
Thickness
Min. 0.8 mm
Electric strength test
With 3000 Vac after humidity treatment
Result
Pass
Transformer part name: T901
Manufacturer: (see appended table 14)
Type: (see appended table 14)
Recurring peak voltage
556Vpk
Required clearance for reinforced insulation
(from table 8 and 9)
4.4mm (BI=SI=2.2mm)
Effective voltage rms
261Vrms
Required creepage distance for reinforced insulation
(from table 11)
5.4mm (BI=SI=2.7mm)
Measured min. creepage distance
Location
inside (mm)
outside (mm)
--
7.0
Primary to core (BI)
4.0
6.0
Secondary to core (SI)
4.0
6.0
Primary to Secondary (RI)
Measured min. clearances
TRF No. IEC60065K
Page 46 of 51
Location
Report No.: 17706907 001
inside (mm)
outside (mm)
--
7.0
Primary to corer (BI)
4.0
6.0
Secondary to core (SI)
4.0
6.0
Primary to Secondary (RI)
Remark:
1. Core is counted as Inter-Medium part. Different concentric winding on bobbin;
2. One side winding is primary windings. The other side winding is secondary;
3. The core outside body is wrapped with 3 layers of insulation tape.
Construction:
TRF No. IEC60065K
Page 47 of 51
4.
TRF No. IEC60065K
Report No.: 17706907 001
Page 48 of 51
Report No.: 17706907 001
Notes:
The unit of the dimension is “mm”.
All transformers have the same construction. They are identical except for manufacturer and model name.
Pin numbers
Hazards winding
3-6
Non-hazards winding
10-12
Bobbin
Material
1. Sumitomo Chemical Co., Ltd. Type
No. PM9820, Phenolic, 150C;
2. Chang Chun Plastic Co., Ltd. Type No.
T375J, Phenolic Molding Compound,
150C.
Thickness
Min. 0.6 mm
Electric strength test
With 3000 Vac after humidity treatment
Result
Pass
Transformer part name: T902
Manufacturer:
(see appended table 14)
Type:
(see appended table 14)
Recurring peak voltage
420Vpk
Required clearance for reinforced insulation
(from table 8 and 9)
4.0mm (BI=SI=2.0mm)
Effective voltage rms
250Vrms
Required creepage distance for reinforced insulation
(from table 11)
5.0mm (BI=SI=2.5mm)
Measured min. creepage distance
Location
inside (mm)
outside (mm)
Primary to Secondary (RI)
/ see note 3
8.7
Primary to core
/ see note 2
/ see note 2
Secondary to core (RI)
/ see note 3
8.7
Location
inside (mm)
outside (mm)
Primary to Secondary (RI)
/ see note 3
8.7
Primary to core
/ see note 2
/ see note 2
Secondary to core (RI)
/ see note 3
8.7
Measured min. clearances
Construction:
1. Concentric windings on phenolic bobbin.
2. The core is considered as primary winding.
3. Triple Insulation Winding is used for secondary winding.
TRF No. IEC60065K
Page 49 of 51
TRF No. IEC60065K
Report No.: 17706907 001
Page 50 of 51
Report No.: 17706907 001
4. WINDING CONSTRUCTION
Notes:
The unit of the dimension is “mm”.
All transformers have the same construction. They are identical except for manufacturer and model name.
Pin numbers
Hazards winding
6-7, 9-10
Non-hazards winding
5-1
TRF No. IEC60065K
Page 51 of 51
Report No.: 17706907 001
Bobbin
Material
Chang Chun Plastic Co., Ltd.
Type No. T375J,
Phenolic Molding Compound,
150C
Thickness
Min. 0.6 mm
Electric strength test
With 3000 Vac after humidity treatment
Result
Pass
--The End of this Test Report--
TRF No. IEC60065K
ATTACHMENT 1
Page 1 of 16
Report No.: 17706907 001
IEC60065K - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
ATTACHMENT TO TEST REPORT IEC 60065
EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
Audio, video and similar electronic apparatus – Safety requirements
Differences according to ............... :
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
Attachment Form No. ..................... :
EU_GD_IEC60065K_II
Attachment Originator ................... :
Intertek Semko AB
Master Attachment ......................... :
Date (2011-09)
Copyright © 2011 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
IEC 60065, GROUP DIFFERENCES (CENELEC common modifications (EN))
Clause
Requirement + Test
Contents
Add the following annexes:
Annex ZA (normative) Other international publications quoted in this standard with
the references of the relevant European publications (See the CB Bulletin)
Annex ZB (nominative) Special national conditions
Annex ZC (informative) A-deviations
Definition
Add after the definition 2.2.12 the following new
definition:
2.2.Z1
(A11:2008) PORTABLE SOUND SYSTEM
small battery powered audio equipment:

whose prime purpose is to listen to recorded or
broadcasted sound; and

that uses headphones or earphones that can
be worn in or on or around the ears; and
Result - Remark
Verdict
P
N/A
 that allows the user to walk around
NOTE Examples are mini-disc or CD players, MP3
audio players or similar equipment.
2.2
In EN 60065:2002/A11:2008
(A12:2011) Delete the definition 2.2.Z1
N/A
ATTACHMENT 1
Page 2 of 16
Report No.: 17706907 001
IEC60065K - ATTACHMENT
Clause
Requirement + Test
3.1
Add the following indent at the end of the list
- Exposure to excessive sound pressures from
headphones or earphones
NOTE A new method of measurement is described
in EN 50332-1, Sound system equipment:
Headphones and earphones associated with
portable audio equipment
– Maximum sound pressure level measurement
methodology and limit considerations – Part 1:
General method for ”one package equipment”, and
in EN 50332-2, Sound system equipment:
Headphones and earphones associated with
portable audio equipment – Maximum sound
pressure level measurement methodology and limit
considerations – Part 2: Guidelines to associate
sets with headphones coming from different
manufacturers.
Result - Remark
Verdict
N/A
In EN 60065:2002
3.1
(A12:2011) Delete the addition of indent regarding sound
pressure excessive
Deleted.
3.Z1
After 3.2 add a new clause 3.Z1:
a) & b) Considered.
(A2:2010)
To protect against excessive current, short-circuits
and earth faults in MAINS, protective devices shall
be included either as integral parts of the
equipment or as parts of the building installation,
subject to the following, a), b) and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the requirements
of 11 shall be included as parts of the equipment;
b) for components in series or parallel with the
mains input to the equipment such as the supply
cord, appliance coupler, r.f.i. filter and switch, shortcircuit and earth fault protection may be provided
by protective devices in the building installation;
c) it is permitted for equipment supplied via an
industrial mains plug or for PERMANENTLY
CONNECTED APPARATUS, to rely on dedicated
over current and short-circuit protection in the
building installation, provided that the means of
protection, e.g. fuses or circuit breakers, is fully
specified in the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for not via an industrial mains
plug or for PERMANENTLY CONNECTED
APPARATUS the building installation shall be
regarded as providing protection in accordance
with the rating of the wall socket outlet.
4.1.1
Replace the text of the note by: NOTE For
ROUTINE TEST reference is made to EN 50514.
N/A
P
N/A
ATTACHMENT 1
Page 3 of 16
Report No.: 17706907 001
IEC60065K - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
Modify indent za) as follows:
5.4.1
Not a PORTABLE SOUND
za)
za) For a PORTABLE SOUND SYSTEM, a warning SYSTEM.
(A11:2008) that excessive sound pressure from earphones and
headphones can cause hearing loss.
N/A
5.4.1
In EN 60065:2002/A1:2006 and EN
(A12:2011) 60065;2002/A11:2008
Delete the modification in indent za)
Add the following clause and annex to the existing
standard and amendments
Not a personal music player.
N/A
Zx Protection against excessive sound pressure from personal music
players
N/A
ATTACHMENT 1
Page 4 of 16
Report No.: 17706907 001
IEC60065K - ATTACHMENT
Clause
Requirement + Test
Zx.1 General
This sub-clause specifies requirements for
protection against excessive sound pressure from
personal music players that are closely coupled to
the ear. It also specifies requirements for
earphones and headphones intended for use with
personal music players.
A personal music player is a portable equipment
for personal use, that:
recorded
can
or broadcast sound or video; and
be worn in or on or around the ears; and
NOTE 1 Examples are hand-held or body-worn portable CD
players, MP3 audio players, mobile phones with MP3 type
features, PDA’s or similar equipment.
A personal music player and earphones or
headphones intended to be used with personal
music players shall comply with the requirements of
this sub-clause.
The requirements in this sub-clause are valid for
music or video mode only.
The requirements do not apply:
an external amplifier; or
used.
NOTE 2 An external amplifier is an amplifier which is not part of
the personal music player or the listening device, but which is
intended to play the music as a standalone music player.
The requirements do not apply to:
equipment;
NOTE 3 Professional equipment is equipment sold through
special sales channels. All products sold through normal
electronics stores are considered not to be professional
equipment.
music players without any kind of digital
processing of the sound signal) that are brought
to the market before the end of 2015.
NOTE 4 This exemption has been allowed because this
technology is falling out of use and it is expected that within a
few years it will no longer exist. This exemption will not be
extended to other technologies.
For equipment which is clearly designed or
intended for use by young children, the limits of
EN 71-1 apply.
Result - Remark
Verdict
N/A
ATTACHMENT 1
Page 5 of 16
Report No.: 17706907 001
IEC60065K - ATTACHMENT
Clause
Requirement + Test
Cont.
Zx.2 Equipment requirements
No safety provision is required for equipment that
complies with the following:
music player with its listening device), where
the acoustic output LAeq,T is ≤ 85 dBA measured
while playing the fixed “programme
simulation noise” as described in EN 50332-1;
and
ided with an
analogue electrical output socket for a listening
device, where the electrical output is ≤ 27 mV
measured as described in EN 50332-2, while
playing the fixed “programme simulation noise” as
described in EN 50332-1.
NOTE 1 Wherever the term acoustic output is used in this
clause, the 30 s A-weighted equivalent sound pressure level
LAeq,T is
meant. See also Zx.5 and Annex Zx.
All other equipment shall:
a) protect the user from unintentional acoustic
outputs exceeding those mentioned above; and
b) have a standard acoustic output level not
exceeding those mentioned above, and
automatically return to an output level not
exceeding those mentioned above when the
power is switched off; and
c) provide a means to actively inform the user of the
ncreased sound pressure when the equipment is
operated with an acoustic output exceeding
those mentioned above. Any means used shall
be acknowledged by the user before activating a
mode of operation which allows for an acoustic
output exceeding those mentioned above. The
acknowledgement does not need to be repeated
more than once every 20 h of cumulative
listening time; and
NOTE 2 Examples of means include visual or audible signals.
Action from the user is always required.
NOTE 3 The 20 h listening time is the accumulative listening
time, independent how often and how long the personal music
player has been switched off.
d) have a warning as specified in Zx.3; and
e) not exceed the following:
1) equipment provided as a package (player with
Its listening device), the acoustic output shall be
≤ 100 dBA measured while playing the fixed
“programme simulation noise” described in EN
50332-1; and
2) a personal music player provided with an
analogue electrical output socket for a listening
device, the electrical output shall be ≤ 150 mV
measured as described in EN 50332-2, while
playing the fixed “programme simulation noise”
described in EN 50332-1.
Result - Remark
Verdict
N/A
ATTACHMENT 1
Page 6 of 16
Report No.: 17706907 001
IEC60065K - ATTACHMENT
Clause
Cont.
Requirement + Test
For music where the average sound pressure (long
term LAeq,T) measured over the duration of the
song is lower than the average produced by the
programme simulation noise, the warning does not
need to be given as long as the average sound
pressure of the song is below the basic limit of 85
dBA. In this case T becomes the duration of the
song.
Result - Remark
Verdict
N/A
NOTE 4 Classical music typically has an average sound
pressure (long term LAeq,T) which is much lower than the average
programme simulation noise. Therefore, if the player is capable
to analyse the song and compare it with the programme
simulation noise, the warning does not need to be given as long
as the average sound pressure of the song is below the basic
limit of 85 dBA.
For example, if the player is set with the programme simulation
noise to 85 dBA, but the average music level of the song is only
65 dBA, there is no need to give a warning or ask an
acknowledgement as long as the average sound level of the
song is not above the basic limit of 85 dBA.
Zx.3 Warning
The warning shall be placed on the equipment, or
on the packaging, or in the instruction manual and
shall consist of the following:
of
5 mm; and
“To prevent possible hearing damage, do not listen
at high volume levels for long periods.”
Figure 1 – Warning label (IEC 60417-6044)
Alternatively, the entire warning may be given
through the equipment display during use,
when the user is asked to acknowledge activation
of the higher level.
N/A
ATTACHMENT 1
Page 7 of 16
Report No.: 17706907 001
IEC60065K - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
Cont.
Zx.4 Requirements for listening devices (headphones and earphones)
N/A
Zx.4.1 Wired listening devices with analogue
Not a listening device.
input
With 94 dBA sound pressure output LAeq,T, the input
voltage of the fixed “programme simulation noise”
described in EN 50332-2 shall be ≥ 75 mV.
N/A
This requirement is applicable in any mode where
the headphones can operate (active or
passive), including any available setting (for
example built-in volume level control).
NOTE The values of 94 dBA – 75 mV correspond with 85dBA –
27 mV and 100 dBA – 150 mV.
Zx.4.2 Wired listening devices with digital input
N/A
With any playing device playing the fixed
“programme simulation noise” described in
EN 50332-1 (and respecting the digital interface
standards, where a digital interface standard
exists that specifies the equivalent acoustic level),
the acoustic output LAeq,T of the listening device
shall be ≤ 100 dBA.
This requirement is applicable in any mode where
the headphones can operate, including any
available setting (for example built-in volume level
control, additional sound feature like
equalization, etc.).
.
NOTE An example of a wired listening device with digital input is
a USB headphone.
Zx.4.3 Wireless listening devices
In wireless mode:
the fixed programme simulation noise described
in EN 50332-1; and
sion standards,
where an air interface standard exists that
specifies the equivalent acoustic level; and
device (for example built-in volume level control,
additional sound feature like equalization, etc.)
set to the combination of positions that maximize
the measured acoustic output for the abovementioned programme simulation noise, the
acoustic output LAeq,T of the listening device shall
be ≤ 100 dBA.
NOTE An example of a wireless listening device is a Bluetooth
headphone.
N/A
ATTACHMENT 1
Page 8 of 16
Report No.: 17706907 001
IEC60065K - ATTACHMENT
Clause
Requirement + Test
Zx.5 Measurement methods
Measurements shall be made in accordance with
EN 50332-1 or EN 50332-2 as applicable.
Unless stated otherwise, the time interval T shall be
30 s.
NOTE Test method for wireless equipment provided without
listening device should be defined.
Result - Remark
Verdict
N/A
ATTACHMENT 1
Page 9 of 16
Report No.: 17706907 001
IEC60065K - ATTACHMENT
Clause
Requirement + Test
Replace the entire subclause in EN 60065:2002
and EN 60065:2002/A1:2006 by:
(A11:2008) Ionizing radiation
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under fault
conditions.
Compliance is checked by measurement under the
following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND, by
any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
NOTE 1 Soldered joints and paint lockings are
examples of adequate locking.
The dose-rate is determined by means of a
radiation monitor with an effective area of 10 cm²,
at any point 10 cm from the outer surface of the
apparatus.
Moreover, the measurement shall be made under
fault conditions causing an increase of the highvoltage, provided an intelligible picture is
maintained for 1 h, at the end of which the
measurement is made.
The dose-rate shall not exceed 1μSv/h (0,1 mR/h)
taking account of the background level.
NOTE 2 These values appear in Directive
96/29/Euratom of 13th May 1996.
A picture is considered to be intelligible if the
following conditions are met:
- a scanning amplitude of at least 70 % of the
usable screen width;
- a minimum luminance of 50 cd/m² with locked
blank raster provided by a test generator;
- a horizontal resolution corresponding to at least
1,5 MHz in the centre, with a similar vertical
degradation;
- not more than one flashover per 5 min.
6.1
Result - Remark
No ionizing radiation source.
Verdict
N/A
ATTACHMENT 1
Page 10 of 16
Report No.: 17706907 001
IEC60065K - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Add the following new clause after Clause 20:
Z1
V-1 min. plastic material or
metal material used for the
(A11:2008) Z1 Resistance to candle flame ignition
enclosure.
A television set shall be so designed that the
likelihood of ignition and the spread of fire caused
by a candle flame is reduced.
NOTE 1 An apparatus with a viewing screen is not
regarded to be a television set if it is declared not to
be so by the manufacturer.
This requirement does not apply to the display
screen of rear projection TV’s.
NOTE 2 This exemption has been allowed because
this technology is falling out of use and it is
expected that within a few years it will no longer
exist. This exemption will not be extended to other
technologies.
NOTE 3 The frame around the screen is not
exempted from the requirements.
Wood and WOOD-BASED MATERIAL with a
thickness of at least 6 mm is considered to fulfil the
V-1 requirement when applying CLC/TS 62441.
Compliance is checked according to CLC/TS
62441.
Verdict
P
NOTE 4 The term vertical, as used in the first dash
of clause 5.2 of CLC/TS 62441, does not mean a
perfectly vertical position. It should be interpreted
as any surface that can be touched by the flame of
a candle of 150 mm height and 20mm diameter
while the candle is still touching the supporting
surface. A typical candle used in the home is
assumed to be 20 mm diameter.
NOTE 5 It is expected that CLC/TS 62441 will in
the future be replaced by a standard, at which time
that standard will become applicable, subject to a
vote by National Committees at the time.
General
13.3.1
14
15.1.1
15.2
16.1
16.2
20
Annex B
Annex G
Annex J.2
Annex N
Delete note 4.
Delete note 4 and note 5.
Delete notes 1 and 2.
Delete note 2.
Delete note 1.
Delete the note.
Delete note 2.
Replace note 1 by: In the CENELEC countries listed in IEC 62151,
special national conditions apply.
Delete the note.
Delete the notes of Table J.1.
Add after the introduction: For ROUTINE TEST reference is made to
EN 50333. (Replaced by EN 50514)
P
ATTACHMENT 1
Page 11 of 16
Report No.: 17706907 001
IEC60065K - ATTACHMENT
Clause
Requirement + Test
Result - Remark
General
(A2:2010)
In IEC 60065:2001/A2
Delete all the “country” notes according to the following list:
5.3
Note
5.4.1 Note
20
Note
For special national conditions, see Annex ZB.
Verdict
P
Bibliography Additional EN standards.
P
ZA
---
Normative references to international publications
with their corresponding European publications
ZB
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS (EN)
2.6.1
DK: The following is added:
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socketoutlets
Justification: Heavy Current Regulations, Section
107.
3.Z1
(A2:2010)
Denmark
Add to the end of the subclause
Due to many existing installations where the
socket-outlets can be protected with
fuses with higher rating than the rating of the
socket-outlets the protection for
pluggable equipment type A shall be an integral
part of the equipment.
Justification:
In Denmark an existing 13 A socket outlet can be
protected by a 20 A fuse.
Refer to clause 15.1.1.Not
class I apparatus.
Protection device in the
equipment.
P
N/A
P
ATTACHMENT 1
Page 12 of 16
Report No.: 17706907 001
IEC60065K - ATTACHMENT
Clause
Requirement + Test
Result - Remark
5.3
(A2:2010)
Finland, Norway and Sweden
Not class I apparatus.
To the end of the subclause the following is added:
Verdict
N/A
CLASS I apparatus
which is intended for connection
to the building installation wiring
via a plug or an appliance coupler, or both and in
addition is intended for connection
to other apparatus or a network shall, if safety
relies on connection to protective earth
or if surge suppressors are connected between the
network TERMINALS and
ACCESSIBLE parts, have a marking stating that the
apparatus must be connected to an
earthed MAINS socket-outlet.
The marking text in the applicable countries shall
be as follows:
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat
uttag”
Finland, Norway and Sweden
5.4
(A11:2008) To the end of 5.4 the following is added:
CLASS I apparatus which is intended for
connection to the building installation wiring via a
plug or an appliance coupler, or both and in
addition is intended for connection to other
apparatus or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
TERMINALS and ACCESSIBLE parts, have a
marking stating that the apparatus must be
connected to an MAINS socket-outlet with
protective earth.
The marking text in the applicable countries shall
be as follows:
In Finland: “Laite on liitettävä
suojamaadoituskoskettimilla varustettuun
pistorasiaan”
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: "Apparaten skall anslutas till jordat
uttag"
See above
N/A
ATTACHMENT 1
Page 13 of 16
Report No.: 17706907 001
IEC60065K - ATTACHMENT
Clause
Requirement + Test
Norway and Sweden
5.4.1
(A11:2008) To the end of 5.4.1 (after the compliance
statement) the following is added:
The screen of the cable distribution system is
normally not earthed at the entrance of the building
and there is normally no equipotential bonding
system within the building. Therefore the protective
earthing of the building installation need to be
isolated from the screen of a cable distribution
system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
“Equipment connected to the protective earthing of
the building installation through the mains
connection or through other equipment with a
connection to protective earthing – and to a cable
distribution system using coaxial cable, may in
some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device providing
electrical isolation below a certain frequency range
(galvanic isolator, see EN 60728-11)”
NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,
for 1 min.
Translation to Norwegian (the Swedish text will also
be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet utstyr – og
er tilkoplet et kabel-TV nett, kan forårsake
brannfare. For å unngå dette skal det ved tilkopling
av utstyret til kabel-TV nettet installeres en
galvanisk isolator mellom utstyret og kabel-TV
nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via jordat
vägguttag och/eller via annan utrustning och
samtidigt är kopplad till kabel-TV nät kan i vissa fall
medföra risk för brand.
Főr att undvika detta skall vid anslutning av
utrustningen till kabel-TV nät galvanisk isolator
finnas mellan utrustningen och kabel-TV nätet.”
Result - Remark
The relevant information shall
be provided when the
apparatus was sold in these
countries.
Verdict
N/A
ATTACHMENT 1
Page 14 of 16
Report No.: 17706907 001
IEC60065K - ATTACHMENT
Clause
Requirement + Test
Result - Remark
13.3.1
NO: To the second paragraph the following is
added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
The input voltage range of this
apparatus covered 230V.
Verdict
P
Denmark
15.1.1
Relevant plug shall be
(A11:2008) The text of the Danish SNC in EN 60065:2002 has provided when the apparatus
was sold in these countries.
been modified as follows:
To the first paragraph the following is added:
In Denmark, supply cords of single-phase
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with the
Heavy Current Regulations, Section 107-2-D1
standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for providing power to
CLASS II apparatus with a rated current of 2,5 A
shall be in accordance with the Heavy Current
Regulation, Section 107-2-D1 standard sheet DKA
1-4a.
Other current ratings socket outlets shall be in
compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DKA 1-3a or DKA
1-3b.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be
in compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DK 1-3a, DK 1-5a
or DK 1-7a.
Justification: Heavy Current Regulations, Section
107-2-D1
N/A
15.1.1
N/A
IE: Apparatus which is fitted with a flexible cable or Relevant plug shall be
cord shall be provided with a 13 A plug in
provided when the apparatus
accordance with Statutory Instrument 525:97, “13 A was sold in this country.
Plugs and Conversion Adapters for Domestic Use
Regulations:1997.
Justification: SI 525: 1997
ATTACHMENT 1
Page 15 of 16
Report No.: 17706907 001
IEC60065K - ATTACHMENT
Clause
Requirement + Test
Result - Remark
15.1.1
No such socket-outlet used.
NO: Mains socket-outlets mounted on CLASS II
apparatus shall comply with the specifications
given in CEE Publ. 7 as far as a applicable, with
the following amendments:
§ 8 Dimensions
a 2.5 A 250 V two-pole socket-outlets for electronic
apparatus shall comply with the enclosed Standard
Sheet I.
Verdict
N/A
§ 24 Mechanical strength
A 2,5 A 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall be
tested
Justification: Act of 24 May 1929 relating to
supervision of electrical installation (TEA 1929/FEL
1998).
15.1.1
UK: Apparatus which is fitted with a flexible cable
Approved plug according to
or cord and is designed to be connected to a mains BS1363-1 provided.
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with a
”standard plug” in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets etc.
(Safety) Regulations 1994, unless exempted by
those Regulations.
NOTE ”Standard plug” is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved conversion
plug.
Justification: SI 1768: 1994
P
ATTACHMENT 1
Page 16 of 16
Report No.: 17706907 001
IEC60065K - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
J.2
NO: After Table J.1 the following is added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
Alternative method not used.
ZC
ANNEX ZC TO EN 60065, A-DEVIATIONS (EN)
5.1
IT: Additional markings on the outside of the TV
receiver in Italian language
The relevant marking shall be
provided when the apparatus
was sold in these countries.
N/A
IT:User instructions in Italian language including a
conformity declaration
The relevant information shall
be provided when the
apparatus was sold in these
countries.
N/A
IT: Certification number on the back cover
It shall be evaluated when
submitted for national
approval.
N/A
N/A
N/A
6.1
DE: The following requirement applies:
No such devices.
For the operation of any cathode ray tube intended
for the display of visual images operating at an
acceleration voltage exceeding 40 kV, authorization
is required, or application of type approval
(Bauartzulassung) and marking.
Justification: German ministerial decree against
ionizing radiation (Röntgenverordnung), in force
since 2002-07-01, implementing the European
Directive 96/29/EURATOM.
NOTE Contact address:
Physikalisch-Technische Bundesanstalt,
Bundesallee 100, D-38116 Braunschweig, Tel.:
Int+49-531-592-6320, Internet: http://www.ptb.de
N/A
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
Justification: Ordinance (1990:944) on Prohibition
in Connection with handling. Importation and
exportation of Chemical Products (Certain Cases)
N/A
Switch shall meet this
requirement when the
apparatus was sold in this
country.
ATTACHMENT 2
Photo Documentation
Report No.:
17706907 001
Type Designation:
HE50K3300UWTS, H50M3300, H50M3306, H50M3308, H50MEC3350
H50MEC3355
Pic001 Front appearance
Pic002 Back appearance
Rev. 1
Page 1 of 10
ATTACHMENT 2
Photo Documentation
Report No.:
17706907 001
Type Designation:
HE50K3300UWTS, H50M3300, H50M3306, H50M3308, H50MEC3350
H50MEC3355
Pic003 Back appearance without stand
Pic004 Marking for signal connectors
Rev. 1
Page 2 of 10
ATTACHMENT 2
Photo Documentation
Report No.:
17706907 001
Type Designation:
HE50K3300UWTS, H50M3300, H50M3306, H50M3308, H50MEC3350
H50MEC3355
Pic005 Marking for signal connectors
Pic006 Internal view without back cover
Rev. 1
Insulation sheet
Page 3 of 10
ATTACHMENT 2
Photo Documentation
Report No.:
17706907 001
Type Designation:
HE50K3300UWTS, H50M3300, H50M3306, H50M3308, H50MEC3350
H50MEC3355
Pic007 Main switch
Pic008 Back cover
Rev. 1
Page 4 of 10
ATTACHMENT 2
Photo Documentation
Report No.:
17706907 001
Type Designation:
HE50K3300UWTS, H50M3300, H50M3306, H50M3308, H50MEC3350
H50MEC3355
Pic009 Power supply board
Pic010 Power supply board
Rev. 1
Page 5 of 10
ATTACHMENT 2
Photo Documentation
Report No.:
17706907 001
Type Designation:
HE50K3300UWTS, H50M3300, H50M3306, H50M3308, H50MEC3350
H50MEC3355
Pic011 Insulation sheet under power supply board
Pic012 Mainboard
Rev. 1
Page 6 of 10
ATTACHMENT 2
Photo Documentation
Report No.:
17706907 001
Type Designation:
HE50K3300UWTS, H50M3300, H50M3306, H50M3308, H50MEC3350
H50MEC3355
Pic013 Mainboard
Pic014 Transformer T831
Rev. 1
Page 7 of 10
ATTACHMENT 2
Photo Documentation
Report No.:
17706907 001
Type Designation:
HE50K3300UWTS, H50M3300, H50M3306, H50M3308, H50MEC3350
H50MEC3355
Pic015 Transformer T831
Pic016 Transformer T901
Rev. 1
Page 8 of 10
ATTACHMENT 2
Photo Documentation
Report No.:
17706907 001
Type Designation:
HE50K3300UWTS, H50M3300, H50M3306, H50M3308, H50MEC3350
H50MEC3355
Pic017 Transformer T901
Pic018 Transformer T902
Rev. 1
Page 9 of 10
ATTACHMENT 2
Photo Documentation
Report No.:
17706907 001
Type Designation:
HE50K3300UWTS, H50M3300, H50M3306, H50M3308, H50MEC3350
H50MEC3355
Pic019 Transformer T902
Pic020 Stand
Rev. 1
Page 10 of 10