CC Series metal access control Manual

CC Series metal access control Manual
CC Series metal access control Manual
1.Description
CC Series is a standalone for two doors, support card, pin, card+pin access way. It is with 2 relays to
control 2 doors and supports up to 2000 users in total,each user can possess one card and one pin.
It can directly drive Lock,Alarm,Ring Bell,and also can connect with Exit Button and Door Contact.
There are 7 working mode with this device.1.Wiegand Reader, 2.Standalone for single door,
3.standalone for two doors,4.with external reader for two doors 5.two units interlocked for two
doors,6.Anti-passback for single door,7.Anti-passback for two door.
Besides, it also supports 1 Master code,2 Manager card, 2 Anti-duress Card users and 2 Anti-duress PIN
users, providing users with easy operations and safety reliability.
2. Features
1.Pure Zinc alloy case;waterproof conform to IP 68
2.Built-in 125KHz OR 13.56MHz card reader (CC1)
Built-in 125KHz and 13.56MHz card reader (CC2)
3.Perfect digital backlit key,the back light can be set to Normal ON,Normal OFF or Human-Approach ON
4.With anti-tamper Alarm,door contact Alarm,Anti-duress Alarm function
5.Add and delete card user quickly With Manager cards
6.Can register and delete user via keypad
7.Master can open the door when entering the setting status
8. Multi working modes: reader,one door,two door, interlock,anti-passback and so on, suitable for many occasions
3.Specification
Input Voltage AC/DC 12V
Idle Current<25mA
Lock output load<1A
Alarm output load<1A
Ring bell load<1A
Card reading distance 40mm Max
Card Frequency:
125KHz for EM and HID
13.56MHz for Mifare
Card transmission format 26-37 bit wiegand
Keypad transmission format:4bit,8bit and Virtual card number
Operating Temperature:-45°C~55° C
Operating Humidity:0%~95%
4.Installation

Remove the back cover from the keypad using the supplied special screw driver

Drill 2 holes on the wall for the Self tapping screws and I hole for the cable

Put the supplied rubber bungs to into the two holes

Fix the back cover firmly on the wall with 2 Self tapping screws

Thread the cable through the cable hole
Attach the keypad to the back cover.
5.Wiring
ZONE1
No.
Marks
1
BELL_A
2
Color
ZONE2
Description
Marks
Color
pink
Doorbell button
D0
green
Wiegand output D0
BELL_B
pink
Doorbell button
D1
white
Wiegand output D1
3
ALARM+
red
Alarm anode
AC1
red
4
AC2
black
AC input
GND
black
GND
5
OPEN2
yellow
Exit button
OPEN1(LED)
yellow
Exit button (for green LED)
6
D_IN2
brown
Door contact
D_IN1(BZ)
brown
Door contact(for buzzer)
7
ALARM2-
gray
Alarm 2
ALARM1-
gray
Alarm 1
8
NO2
Blue
Relay 2 NO end
NO1
Blue
Relay 1 NO end
9
COM2
purple
Relay2Com
COM1
Purple
Relay1 Com
10
NC2
orange
Relay2 NC end
NC1
Orange
Relay1 NC end
6.Sound and Light Indication
Description
AC1 (+12V)
Operation
LED Color
Standby
Red flash
Press key
Di
Read card
Green
Door 1 Open
Green
Door 2 Open
Green
Operation Successful
Flash
Green
Operation Failed
DiDiDiDiDiDiDi
PIN Inputting
Red
Card&PIN Reading
Red
Multi Card Reading
Red
Under Menu
Red
Under Setting
Orange
Manager Card Enter
Orange
Manager Card Exit
Alarm
7
Buzzer
DiDi
Red Flash
Di-
Red Quick Flash
Alarm
Quick Programming Guide
7.1 Administrator Setting
Stand
by
Red
Flash
*
7.2
Maste
r Code
Red
Maste
r
code#
Menu
Setting
Red
Orange
00
01
02
03
04
05
06
07
51
52
Remarks
New master code# Repeat new master code #
(Note:Code length:6-8 digits)
Read Manager Add Card
Read Manager Delete Card
Read Anti-duress card (Zone 1)
Read Anti-duress card (Zone 2)
Anti-duress PIN# (Zone 1)
Anti-duress PIN# (Zone 2)
0000#
Factory
default:999999
Default:Zone 1
Functions
Change the master code
Set Manager Add Card
Set Manager Delete Card
Set Zone1 Anti-duress card
Set Zone2 Anti-duress Card
Set Zone1 Anti-duress PIN
Set Zone2 Anti-duress PIN
Delete All Users
Master open Lock 1
Master open Lock 2
User setting for Zone 1
Standb
y
Red
Flash
*
Master
Code
Red
Master
code
#
Menu
Red
11
12
13
14
15
Setting
Remarks
Functions
Orange
Read card
User ID number# read card
Card number#
ID number#card number#
User ID number#PIN#
Read card
User ID number#
Card number#
0#
1#
2#
0-99#
0#
1#
Users
can
be
added
continuously without exiting
programming mode
Users
can
be
deleted
continuously without exiting
programming mode
Default 2
Default 5
Default 0
To add card users
To add PIN users
To delete users
Entry by Card
Entry by card+PIN
Entry by either Card or PIN
Set door relay time
Relay Setting-Pulse mode
Relay Setting-Toggle mode
16
17
1-10#
User
ID
number#,card
number#,card quantity#
Default 1
To set open door by multi cards
To add a series cards users
User setting for Zone 2
Standb
y
Red
Flash
*
Master
Code
Red
Master
code
#
Menu
Setting
red
orange
21
Read card
User ID number# read card
Card number#
ID number#card number#
User ID number# PIN#
Read card
User ID number#
22
Card number#
0#
1#
2#
0-99#
0#
1#
1-10#
User
ID
number#,card
number#,card quantity#
23
24
25
26
27
Remarks
Functions
Users
can
be
added
continuously without exiting
programming mode
Users
can
be
deleted
continuously without exiting
programming mode
Default 2
To add card users
To add PIN users
To delete users
Entry by Card
Entry by card+PIN
Entry by either Card or PIN
Set door relay time
Relay Setting-Pulse mode
Relay Setting-Toggle mode
To set open door by multi cards
To add a series cards users
Default 5
Default 0
Default 1
7.3 System Setting
Standby
Red
Flash
*
Master
Code
Red
Menu
Setting
red
orange
Master
code
#
30
31
32
33
34
35
7.4 User optional setting
0-15#
0#
1#
2#
3#
4#
5#
6#
26-37#
0-2#
1-3#
0#
1#
2#
Remarks
Functions
Default 0
When device reset
to
factory
default ,the setting
is still valid
To set facility code
Wiegand reader
Standalone for single door(Factory
default setting)
Standalone for two doors
With external reader for two doors
Two units interlocked for two doors
Anti-passback for single door
Anti-passback for two door
To set Wiegand format
To set keypad transmission format
Default 26
When device reset
to
factory
default ,the setting
is still valid
Default 1
Default 0
To set alarm time
Safe mode 0
Safe mode 1
Safe mode 2
Standby
Red Flash
*
Maste
r
Code
Red
Maste
r code
#
Menu
red
41
42
43
Setting
Remarks
Functions
orange
0#
1#
0#
1#
2#
0#
1#
Default 1
Default 2
Default 1
Buzzer will be be in silence except enter the
programming mode
Buzzer will sound when press the key
Disable keypad backlight
Enable keypad backlight
Automatic mode,Normally it is off(sleeping mode)
but wake up with human approach
LED Light Disable when stand-by status
LED flash when stand-by status
Instruction:
1.Master code must be 6-8 digits, Anti-duress PIN must be 8 digits,user PIN is 4-6 digits,The 1st digit of user PIN and Anti-duress
PIN in Zone1 must be 1; The 1st digit of user PIN and Anti-duress PIN in Zone 2 must be 2.
2.the user ID number is any number among 1-2000,Invalid 0 can be omitted; card number must be 8 or 10 digits,if the card number is
less than 8 or 10 digits, input 0 before the card number.
3.Door open time is 0-99 second,0=50mS
4.when register one card user into the device, the device will automatically generate a PIN 1234 , this PIN cant open the door door.
5.when an invalid master pin is pressed the device will go back to the standby status after 5 seconds, when a valid PIN is entered it
will go back to standby status after 30 seconds.
6.in operating the keypad, pressing # means to confirm the input digits ,In operation of a cycle adding or deleting cards, pressing #
means to end the cycle operation and back the up operation; pressing * means to exit the operation.
7. When add a series cards, this unit will make the ID number and card number initial value; after adding one user, then it will
increase the ID number and card number automatically ,Until the specified number of card is added.the card number must be
consecutive card quantity is between 1-2000.
8. Working mode and keypad transmission format have been set before shipping, customer can change according to requirement, but
when device reset to factory default, the setting is still valid.
9.when users of Zone 1 is registered successfully, LED will turn green; when users of Zone 2 is registered successfully, LED will be
green flash.
8. Administrator setting
Administrator setting on keypad
Press
*
Master code # factory default:999999,
8.1 Change the master code
Press
00
new code #
repeat new master code#
Note: Master Code length:6~8 digits
8.2 Set Manager card
Set manager add card
Press
01
read manager add card
Set manager delete card
Press
02
read manager delete card
Note: when add the new manager card, the new one will automatically cover the old card, only one manager card for one device
8.3 Set Anti-duress card
Set Anti-duress card for Zone 1
Press
03
read anti-duress card (Zone 1)
Set Anti-duress card for Zone 2
Press
04
read anti-duress card (Zone 2)
Note: when add the new anti-duress card, the new one will automatically cover the old card, only one anti-duress card for one device
8.4 Set Anti-duress PIN
Set Anti-duress PIN for Zone 1
Press
05
8-digit duress PIN#(Zone 1)
Set Anti-duress card for Zone 2
Press
06
8-digit duress PIN#(Zone 2)
st
Note: 1.the 1 digit must be 1 for Zone 1
2.the 1st digit must be 2 for Zone 2
3. when set the new anti-duress PIN, the new one will automatically cover the old anti-duress PIN, only one anti-duress PIN for one
device
8.5 Delete all users
Press
07
0000 #
Note: both zone 1 and zone 2 will be deleted. This is a dangerous option, so use with care.
8.6 Set administer open lock
Set administer open Lock 1
Press
51
Set administer open Lock 2
Press
52
8.7 Users setting for Zone 1
8.7.1
read card to add user
Press
11
read card #
read card ...
#
8.7.2 use ID Number and read card to add user
Press
11
ID number #
read card
...
ID number # read card
...
#
8.7.3 use card number
Press
11
card number #
...
card number#
...
#
Note: 1.Card number must be 8 or 10 digits, if the card number is less than 8 or 10 digits, input 0 before the card number
2.Automatically increases, the user ID will be generated by the machine automatically, the range is 1 ~ 2000, and
automatically search from 1 to 2000
8.7.4
Use ID number and card number to add user
Press
11
ID number #
8-digits card number #
... ID number# 8-digits card number#
...
#
Note:1.ID number is 1~4 digits, the range is 1~2000, 1,01,001,0001, all these mean ID number 1.
2.add card user will generate one “1234 “PIN, this PIN cant open door, only for user modify PIN
8.7.5 use ID number and PIN to add user
Press
11
ID number#PIN #
...
ID number#PIN# ... #
Note: this fit PIN user, pin is irrelevant
with card, the PIN is any 4-6 digits,1st digits must be 1 for Zone 1 with the exception of
1234 which is reserved.
8.8 Delete user
8.8.1 read card to delete user
Press
12
read card
read card
...
#
8.8.2 use ID number to delete user
Press
12
ID number #
ID number #
...
#
8.8.3 use card number to delete user
Press
12
card number #
card number #
...
#
8.8.4 delete all users
Press
07
0000
#
Note: both zone 1 and zone 2 will be deleted.
8.9 Set opening door mode:
8.9.1 Entry is by card only
Press
13
0
#
8.9.2 Entry is by card and PIN together
Press
13
1
#
8.9.3 Entry is by card or PIN (factory default)
Press
13
2
#
8.10 set door relay time
Press
14
0~99
#
Note: 0~99 is to set the door delay time 0-99 seconds, factory default is 5 seconds
8.11 Set Relay mode
Relay setting -pulse mode
Press
15
0
#
Every time a valid card/tag read or PIN input, the relay will operate,
for the pre-set relay pulse time. (Factory default setting)
Relay setting-Toggle mode
Press
15
1
#
Every time a valid card/tag read or PIN input, the relay changes state, which will not turn back until read card/tag or input PIN again
8.12 Set opening door by multi cards
Press
16
card quantity
#
Note: the door will be opened only after
reading all the valid multi cards up to the card quantity setting. It is only for card entry
mode(Factory default setting :1)
8.13 Add a series consecutive cards users
Press
17
ID number #
card number #
card quantity #
Note: the card number must be consecutive card quantity is between 1~20000; card number is 10 digits or 8 digits
8.14 User setting for Zone 2
The method is the same with Zone 1, corresponding menu should be 21,22,23,24,25,26,27
8.15 system setting
8.15.1 To set facility code
Press
30
0~15
#
Note: code should be 0~15, factory default setting :0
8.15.2 Wiegang Reader
Press
31
0
#
8.15.3 standalone for single door(Factory default setting)
Press
31
1
#
8.15.4 Standalone for two doors
Press
31
2
#
8.15.5 With external reader for two doors
Press
31
3
#
8.15.6 Two units interlocked for two doors
Press
31
4
#
8.15.7 Anti-passback for Single door
Press
31
5
#
8.15.8 Anti-passback for two doors
Press
31
6
#
8.16 To set wiegang format
Press
32
26 34 37
#
Note: factory default setting :26
8.17 setting keypad transmission format
Press
33
0~2
#
Note: keypad transmission format is 0 1 2, factory default is 0; when device reset to factory default, the setting is still valid.
8.18 Setting alarm time
Press
34
1~3
#
Note: 1. factory default is 1 minute
2. when device reset to factory default, the setting is still valid.
8.19 setting safe mode
8.19.1 normal mode (factory default)
Press
35
0
#
8.19.2 dead mode
Press
35
1
#
If read invalid card or input wrong PIN 10 times in 10 minutes, system will be dead for 10 mins
8.19.3 alarm mode
Press
35
2
#
if read invalid card or input wrong PIN 10 times in 10 minutes, external alarm and built-in buzzer will work.
8.20
user optional setting
8.20.1
Press
setting keypad tone OFF or ON
41
0
#
The device will be in silence except enter the programming mode
Press
41
1
#
The device will give the voice when press the keys (Factory default setting)
8. 20.2 setting keypad backlight
Disable keypad backlight
Press
42
0
#
Enable keypad backlight
Press
42
1
#
Automatic mode (factory default setting)
Press
42
2
#
Normally it is off(sleeping mode) but wake up with human approach
8.20.3 setting LED light (stand-by status)
Disable LED light
Press
43
0
#
Flash LED light (factory default setting)
Press
43
1
#
Manager card operation
8.21 add user for Zone1
Read Manager Add Card, read user cards continuously, read Manager Add card again.
8.22 delete user for Zone 1
Read Manager Delete Card, read user cards continuously, read Manager Delete card again.
9 User Operation
9.1 Entry by card mode,Set multi cards to open door when card quantity is 1
Read user card, lock will be unlocked
9.2 Entry by card mode,Set multi cards to open door when card quantity is 2-10
Read these cards one by one, present each card in 5 seconds,
lock will be unlocked
9.3 Entry by card and PIN
Present card, then press PIN(4 to 6 digits ), #, lock will be unlocked
9.4 Entry by card or PIN mode
Present card, lock will be unlocked
Or Press PIN(4 to 6 digits ), #, lock will be unlocked
9.5 Relay mode
Relay setting -pulse mode
every time a valid card/tag read or PIN input, the relay will operate, for the pre-set relay pulse time.
Relay setting-Toggle mode
Every time a valid card/tag read or PIN input, the relay changes state, which will not turn back until read card/tag or input PIN again
9.6 Modifyuser PIN (no need enter programming mode)
*, read user card, press old PIN, #, new PIN # new PIN #
Or *, press ID number # old PIN# new PIN # new PIN #
Notice: user who dont have user card must get ID number and origin PIN from Admin, Zone 1 users PIN must start with 1,
Zone 2 users PIN must start with 2.
10 Alarm function
10.1 Anti-tamper alarm
if the device is disassembled
illegally, the buzzer and the external alarm will operate.
10.2 Door contact alarm
When connect with door contact, if the door is opened illegally, the buzzer and the external alarm will operate.
10.3 The Anti-duress alarm
When read zone 1 anti-duress card/input 8-digit anti duress PIN or zone 2 anti-duress card/input 8-digit anti duress PIN, then press #,
The corresponding lock will open, at the same time, the external alarm witll operate,but the device buzzer will not operate.
10.4 remove alarm
read valid user card, manager card or input master code, then alarm will be removed. If no any operation, alarm will be removed
automatically after 1 min.
11 Multi working mode:
There are 7 working mode with this device.1.Wiegand Reader, 2.Standalone for single door,
3.standalone for two doors,4.with external reader for two doors 5.two units interlocked for two
doors,6.Anti-passback for single door,7.Anti-passback for two door.
The factory default is Standalone for single door (we can change the default model according to
customer order). User can modify the working mode, when the device reset to factory default,the setting is still
valid.
11.1 Wiegand Reader mode
In this mode, the access control works as reader,connected with the common access controller, it has following function.
Modify master pin
Set facility code
Set the card transmission format
Set the keypad transmission format
Set optional setting
Anti-Tamper alarm
When LED level is low,indicator light(LED) will turn into green, after 30 seconds or LED level rising, LED will back to normal.
When BZ level is low,the buzzer will beep,after 30 seconds or BZ level rising, the buzzer will back to normal.
When it used as the reader, both card number and keypad transmits in Wiegang format,the output data are shown by the low level of
DO&D1 wire:
D0:low level means 0,green wire
D1:Low level means 1,white wire
The Pulse width of low level is 100uS,bit period is 1.6mS
The digits of card number can be set to 26-37 bit, should be matched with the controller.(Factory default is 26Bit)
Keypad transmission can be set in the following 3 modes(modes can be set by user)
Model 0: Virtual card number
The reader will transmit the PIN data when it receives the last key(#) press after PIN code
Format: Decimal card number with 10 digits, Facility code(1st~4th digit)+PIN Code(5th-10th digit)
Facility code is any digits between 0~15,PIN code is 4~6 digits
Example:facility code :15
PIN code:9999
Press 9999 #, then output format will be: 0015009999
PIN code: 999999
Press 999999#,then output format will be 0015999999
Model 1: 4 Bit
The output data is provided in following format after every key is pressed:
key
Output in hex
Output in Binary
0
0
0000
1
1
0001
2
2
0010
3
3
0011
4
4
0100
5
5
0101
6
6
0110
7
7
0111
8
8
1000
9
9
1001
*
A
1010
#
B
1011
Model 2: 8 Bit
The output data is transmitted in following format after every key is pressed:
key
Output in hex
Output in Binary
0
0
11110000
1
1
11100001
2
2
11010010
3
3
11000011
4
4
10110100
5
5
10100101
6
6
10010110
7
7
10000111
8
8
01111000
9
9
01101001
*
A
01011010
#
B
01001011
11.2 Standalone for single door
In this mode, the device supports connecting external card reader for exiting door.
The users of Zone 1 or external can open the door by valid card or PIN.
11.3 Standalone for two doors
In this mode, users are for controlling two doors. Read valid card or input PIN of Zone 1 on this unit, door 1 will be opened; reading
valid card or input PIN of Zone 2 on this unit, door 2 will be opened.
Remark: the common card for Zone 1 and Zone 2 can only open door 1.
11.4 With external reader for two doors
In this mode, this unit is for entering door 1,and external reader is for entering door 2.
Read valid card or input of Zone 1 on the machine, door 1 will open; read valid card or input PIN of Zone 2 on external reader, door
2 will open.
Remark: the common card for Zone 1 and Zone 2 can open door 1 on this unit, and open door 2 on external reader.
11.5 Two units interlocked for two doors
The interlock function is mainly used in banks ,prisons,and other places where a higher level security is required.
When and only door 2 closed, read valid card / input PIN on this machine, door 1 will open; when and only door 1 closed, read valid
card/input PIN on external reader, door 2 will open.
Remark: The valid card /PIN is only for users of Zone 1,users of zone 2 are invalid.
11.6 Anti-passback for Single door
In this mode, this unit install outside is for entering door, external reader inside for exiting door, the users can only enter door when
read valid card on the machine, and exit from the inside external reader. If without the entering record from the machine, the users
can not exit from the inside reader, also the Users can’t enter in twice without the first exit record.
Remark: this is only for card users of Zone 1,PIN users of Zone 1 an all users of Zone 1 are invalid.
11.7 Anti-passback for two doors
In this mode, this unit on door 1 is anti-passback master unit, and external reader on door 2 aa the anti-passback auxiliary
unit.then they build up a two doors anti-passback system,which is normally used for parking lot.
The users can only enter door 1 when read valid card on this unit, and exit from door 2 when read valid card on external
reader. If without the entering record from door 1, the users can not exit from the door 2, also the users can’t enter in twice
without the first exit record.
Remark, this is only for card users of Zone 1,PIN users of Zone 1 and all users of Zone 2 are invalid.
12 diagram for 7 working mode
12.1
Wiegand Reader mode
12.2
Standalone for single door
12.3
Standalone for two doors
12.4
With external reader for two doors
12.5
Two units interlocked for two doors
12.6
Anti-passback for Single door
12.7
Anti-passback for two doors
13 Instance Operations
13.1 Modify master code as 201200
press
*
999999
#
00
201100 #
201100
#
.
13.2 Set Anti-duress PIN of Zone 1 as 12012000
press
*
201100
#
05
12012000
#
.
13.3 add last 8 digit card number as 00967865 and 86998736 user of Zone 1
Press
*
201100
#
11
00967865 #
86998736
#
.
13.4 add first 10 digit card number as 0098786500 and 8699873600 user of Zone2
Press
*
201100
#
21
0098786500 #
8699873600
#
.
13.5 add ID user 006, PIN 201200, Zone 2 user
press
*
201100
#
21
6 # 201200
#
.
13.6 set open mode of Zone 1 as card+PIN
press
*
201100
#
13
1
#
.
13.7 rapid increase consecutive numbers 1000 cards(start with 00987865 ID is 005)
press
*
201100
#
17
05 #
00987865 #
1000
#
.
13.8 set working mode as reader mode
press
*
201100
#
31
0
#
.
13.9 set card output format as WG34
press
*
201100
#
32
34
51
.
#
.
13.10 set master open lock 1
press
*
201100
#
14 Simple Troubleshooting
Code
1
Fault
Close Read range
Fault Cause
Quality of card
2
Problem in PIN
setting
1.PIN is not standard
2.Set Password at reader mode
3
PIN can’t open
door
1 use PIN 1234
2 entry mode setting
4
Alarms at normal
condition
While installation, light leak
under bottom
6
No responds
after card reading
Units are not in ready mode
7
Keypad light is
not bright
8
Can’t enter
master mode
Soulutions
Use original card
1.first number of PIN should be 1 or 2,match with Area number
2.PIN shouldn’t be 1234
3. PIN is 4 to 6 digits
4.don’t set PIN at reader mode
1.1234 is original PIN, can’t open the door, should be modified as
other PIN
2.set open mode as entry by card or PIN.
While installation, device should closed to the wall
5
Mode of keypad light setting is
wrong
Forget master code
Press * key, light flash, units back to ready mode
1.set keypad light as shine or auto
2.under auto mode,light shine after press keypad,delay 30
seconds
Reset to Factory Default,master code will be 999999,only
installer data is restored, user data will not be affected
15 To Reset to Factory Default
a. Disconnect power from the unit
b. Press and hold # key whilst powering the unit back up
c. On hearing two “Di” release # key, system is now back factory settings
Please note only installer data is restored, user data will not be affected
16
Packing List
Name
Model/size
Quantity
Keypad
CC1/CC2
1
User manual
CC1/CC2
1
Remarks
Self tapping screws
Φ4mm×27 mm
2
Used in fixing
Rubber plug
Φ6mm×30 mm
2
Used in fixing
Star screw driver
Φ20mm×60mm
1
Special for Keypad
two-electrode valve
1N4007
1
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement