Advertisement
Advertisement
Introduction EPA does not endorse any product or service. INTRODUCTION Section INCANDESCENT Section HALOGEN Section HIGH INTENSITY DISCHARGE Section FLUORESCENT / BALLAST Section COMPACT FLUORESCENT Section STAGE AND STUDIO Section MINIATURE AND SEALED BEAM Section PROJECTION Section APPENDIX Section This latest edition of the GE product catalog has been updated to help you more easily select the GE lighting products that best meet your needs. Technical data in this catalog (life, lumens, wattage, etc.) are nominal values, subject to manufacturer’s tolerances. All technical data in this catalog is based on laboratory tests conducted under controlled conditions. Performance of individual lamps may vary. Because of frequent design improvements, the values listed may not be current ratings. Technical bulletins may be issued from time to time if changes in ratings occur prior to the next catalog printing. Technical Support 1-800-GE LAMPS For the most up-to-date, comprehensive product information, visit the GE Lighting website at www.gelighting.com. i 1 2 3 4 5 6 7 8 A imagination at work © Copyright General Electric Company 2006 GE Consumer & Industrial Lighting Producing Efficiency ecomagination SM The future can seem pretty intimidating: Our known reserves of oil and natural gas are expected to be depleted by 2045, the climate is changing, and more than a billion people lack clean water. At GE, we believe some of the world’s most pressing challenges present an opportunity to do what we do best: imagine and build innovative solutions that benefit our customers and society at large. As a global leader in energy, technology, manufacturing, and infrastructure, GE is uniquely suited to help solve environmental challenges, today and for generations to come. Our customers want a more prosperous, cleaner future. By harnessing our most abundant renewable resource the imagination of our people -we can create that future with them. We are taking a new approach to solving some of our customers’ toughhest environmental problems. We call it ecomagination. Impact of ecomagination: If every household in the U.S. replaced one 100-watt Incandescent light bulb with a GE compact fluorescent bulb equivalent in light output, over the bulb’s life, we would save enough energy to power more than 1 million U.S. homes for an entire year. Our Heritage, Our Future We believe that better technology is the answer to our customers’ environmental challenges. And we are confident we can find tomorrow’s solutions to those challenges just as we have since the days of our founder, Thomas Edison. Throughout our 127-year history, we have invented solutions to meet our customers‘ greatest needs. Over many years, we have developed one of the broadest ranges of environmentally advanced technologies. We will build on this legacy of success by researching and developing next-generation clean technologies. Our goal is to be a leader in bringing clean energy, air, and water and improved quality of life-to all of the world’s citizens. imagination at work ecomagination Products All Screw-in CFLs Ultra T8 Lamps T5 Lamps UltraMax® Ballasts UltraStartTM Ballasts Halogen-IR Diamond Precise® On the way to certification CMH® Lamps ecomagination SM Products Benefits ecomagination Benefits Additional Benefits Starting on page 5-10 All ENERGY STAR CFLs All Screw-in products Energy Savings up to $108* per lamp Up to 13x longer life when using a 42 watt CFL to replace a 150W a-line Ultra T8 Lamps • F28 • Watt-Miser® • Hi Lumen Starting on page 4-9 Energy Savings up to All products Ecolux®, $148* per 4-lamp Fixture Available in CVG when using a F28 & UltraMax® ballast to replace a Std. T12 system Starting on page 4-7 T5 Lamps • High Efficiency • High Output All products Ecolux®, Energy Savings up to $132* per 6-lamp Fixture Available in CVG when using a T5 fixture to replace a Std. 400 Metal Halide system Starting on page 4-37 UltraMax® Ballasts T8 Ballasts Energy Savings up to Multi-Voltage $148* per 4-lamp Fixture when using a F28 & UltraMax® ballast to replace a Std. T12 system Starting on page 4-38 UltraMax® Ballasts T5 & T8 Ballasts Energy Savings up to Programmed Start $148* per 4-lamp Fixture Multi-Voltage when using a F28 & UltraStartTM ballast to replace a Std. T12 system Starting on page 2-5 Halogen-IR • PAR38 HIR & XL • PAR30 HIR & XL Energy Savings up to $13.20* per lamp Up to 6000 hour life when using a Retail HIRTM to replace a Std. Halogen Diamond Precise® Q21EMR16 Starting on page 2-9 Energy Savings up to $14.50* per lamp Up to 2x Longer Life when using a 21 watt Diamond Precise® to replace a 50R20 On the way to certification CMH® Lamps • 400 Watt • 350 Watt • 250 Watt Starting on page 3-9 Energy Savings up to $160.00* per lamp SPXX color – CRI 90+ when using a 350W & e-HID UltraMaxTM ballast to replace a Std. 400 watt MH system * @ 10¢per kWh over life of lamps. Actual savings depends on specific lamps compared. GE Consumer & Industrial Lighting We’ve got the fastest way to slow this down. Saving energy is good business. Energy-efficient lighting from GE may be the fastest, easiest way to slow your meter down and add dollars to your bottom line. That’s why GE has more than increased our product development investment with a clear goal to be the industry’s energy-saving leader. The result is a whole new line of leadership products, like the F28 UItraMax® system. Combining our 28-watt T-8 lamp with a high-efficiency UltraMax® ballast delivers up to 44% energy savings over T-12 systems. In some cases, pay back is less than a year. 27% Savings replacing standard halogen PARs with the Retail HIRTM for accent, merchandising and general lighting. 72% Savings when you replace 150-watt incandescent lamps with our 42-watt CFL. 44% Savings when you replace T12 System with GE’s Ultra Lamps and UltraMax® Ballast. The GE 42-watt compact fluorescent equals the light output of a 150-watt incandescent. That’s a savings of 108 watts. TM The new Retail HIR Halogen uses 27% less energy, with double the life of a standard halogen PAR. Think your meter is spinning too fast? GE Lighting: Your #1 energy-saving choice imagination at work 50%+ Savings when you replace standard PARs with GE ConstantColor® CMH® lamps. GE Consumer & Industrial Lighting The newly expanded GE Lighting and Electrical Institute World famous training and lighting education center now also offers curriculum for electrical distribution systems! Impressive, full-scale lighting demonstration spaces. Comprehensive electrical distribution product center, complete with “control room” simulations. Variety of scheduled conferences offered throughout the year, led by experienced lighting and electrical distribution professionals. And e-tools from the Institute: Mondays @ noon - Live, on-line training offered each week to sharpen your product and market knowledge Value*Light – GE’s award-winning cost of light analysis program The Lighting Toolkit – a collection of 7 simple estimating tools including a Simple Energy Calculator, Lighting Layout Estimator, and the Watts Per Square Foot Estimator. The Lighting AssistantTM - a set of 26 user-friendly tools including Value*Light, the Lighting Toolkit, 2005 Energy Policy Act Tax Incentive Calculator and much, much more! Call 1-800-255-1200, or visit www.gelighting.com imagination at work GE Consumer & Industrial Lighting See What’s Available Online! Focus on Products • Completely redesigned online catalog • Improved search capability • More product details • Highlight energy saving products • Ballast and product specifications Segment Driven Value & Applications • Hospitality • Restaurant • Healthcare • Retail • Property management • Residential builders • Automotive • Oil and gas • Lighting designers More Tools & Resources • Online product catalog • Literature library • Conferences • Environmental information • MSDS sheets • TCLP test results For more information, visit www.gelighting.com imagination at work • IES photometric downloads • Lamp and ballast recycling • Simple energy estimator • Lighting layout estimator • Cost of waiting estimator Incandescent Lamps GENERAL INFORMATION INCANDESCENT LAMPS (CONTINUED) 150 Watts................................................................................................................................1-17 175 Watts................................................................................................................................1-18 200 Watts................................................................................................................................1-18 240 Watts................................................................................................................................1-19 250 Watts................................................................................................................................1-19 300 Watts................................................................................................................................1-19 350 Watts................................................................................................................................1-20 375 Watts................................................................................................................................1-20 400 Watts................................................................................................................................1-20 500 Watts................................................................................................................................1-20 750 Watts................................................................................................................................1-21 1000 Watts .............................................................................................................................1-21 Bulb Identification ............................................................................................................... 1-2 Filament Identification ........................................................................................................ 1-2 Base Identification ................................................................................................................ 1-2 Lamp Locator .......................................................................................................................... 1-3 Introduction.............................................................................................................................. 1-4 GE Reveal® A-Line Bulbs .................................................................................................. 1-5 GE Survivor™ A-Line Bulbs ............................................................................................... 1-5 GE covRguard® A-Line Bulbs ......................................................................................... 1-5 GE Long Life Floodlight or Spotlight ........................................................................... 1-5 Catalog Headings ............................................................................................................... 1-6 Footnotes ..............................................................................................................................1-26 INCANDESCENT LAMPS MISC. INCANDESCENT LAMP TYPES ..................................1-21 EXPORT-ONLY 3 Watts ....................................................................................................................................... 1-7 4 Watts ....................................................................................................................................... 1-7 6 Watts ....................................................................................................................................... 1-7 7 Watts ....................................................................................................................................... 1-7 7.5 Watts ................................................................................................................................... 1-7 10 Watts .................................................................................................................................... 1-7 11 Watts .................................................................................................................................... 1-8 12-13.5 Watts ......................................................................................................................... 1-8 15 Watts .................................................................................................................................... 1-8 15/135/150 Watts ................................................................................................................. 1-8 18 Watts .................................................................................................................................... 1-8 20 Watts .................................................................................................................................... 1-8 21.5 Watts................................................................................................................................. 1-8 25 Watts .................................................................................................................................... 1-8 27 Watts ..................................................................................................................................1-10 30 Watts ..................................................................................................................................1-10 30/70/100 Watts .................................................................................................................1-10 33 Watts ..................................................................................................................................1-10 34 Watts ..................................................................................................................................1-10 40 Watts ..................................................................................................................................1-10 45 Watts ..................................................................................................................................1-11 50 Watts ..................................................................................................................................1-11 50/100/150 Watts ...............................................................................................................1-12 50/200/250 Watts ...............................................................................................................1-12 52 Watts ..................................................................................................................................1-12 54 Watts ..................................................................................................................................1-12 55 Watts ..................................................................................................................................1-13 60 Watts ..................................................................................................................................1-13 65 Watts ..................................................................................................................................1-13 67 Watts ..................................................................................................................................1-14 69 Watts ..................................................................................................................................1-14 70 Watts ..................................................................................................................................1-14 70/170/240 Watts ...............................................................................................................1-14 75 Watts ..................................................................................................................................1-14 85 Watts ..................................................................................................................................1-15 88 Watts ..................................................................................................................................1-15 90 Watts ..................................................................................................................................1-15 95 Watts ..................................................................................................................................1-15 100 Watts................................................................................................................................1-15 100/200/300 Watts ............................................................................................................1-16 110 Watts................................................................................................................................1-16 116 Watts................................................................................................................................1-16 120 Watts................................................................................................................................1-16 135 Watts................................................................................................................................1-17 65 Watts ..................................................................................................................................1-21 75 Watts ..................................................................................................................................1-21 85 Watts ..................................................................................................................................1-21 120 Watts................................................................................................................................1-21 150 Watts................................................................................................................................1-21 E27 BASE-EXPORT 80 Watts ..................................................................................................................................1-21 100 Watts................................................................................................................................1-21 120 Watts................................................................................................................................1-22 150 Watts................................................................................................................................1-22 EXPORT PAR 300 Watts................................................................................................................................1-22 LUMEN RATED TRAFFIC SIGNAL 165 Watts................................................................................................................................1-22 AIRPORT 30 Watts ..................................................................................................................................1-22 40 Watts ..................................................................................................................................1-22 45 Watts ..................................................................................................................................1-22 120 Watts................................................................................................................................1-22 200 Watts................................................................................................................................1-22 204 Watts................................................................................................................................1-22 620 Watts................................................................................................................................1-23 1000 Watts .............................................................................................................................1-23 1200 Watts .............................................................................................................................1-23 MULTIPLE STREET LIGHTING ..............................................1-23 DECORATIVE 3 Watts .....................................................................................................................................1-23 15 Watts ..................................................................................................................................1-23 25 Watts ..................................................................................................................................1-23 40 Watts ..................................................................................................................................1-24 60 Watts ..................................................................................................................................1-25 75 Watts ..................................................................................................................................1-25 100 Watts................................................................................................................................1-26 150 Watts................................................................................................................................1-26 PORTABLE LIGHTING PRODUCTS .......................................1-26 CROSS REFERENCE ..............................................................1-27 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B 1-1 Incandescent Lamps BULB IDENTIFICATION DIA. DIA: Diameter of bulb at widest point. MOL: Maximum Overall Length including base or pins. LCL: Distance between the center of the arc tube and the Light Center Length reference plane. Note: Lamp drawings are not drawn to scale. Be sure to check size and dimension information when identifying each lamp. DIA. MOL MOL LCL To convert inches to millimeters, multiply the dimension (in inches) by 25.4 (i.e. 1.5” x 25.4 = 38.1 mm). FILAMENT IDENTIFICATION C-9 C-6 CC-6 C-17 C-22 C-13 C-13D C-8 CC-8 C-8 CC-8 C-5 C-7A C-2V CC-2V BASE IDENTIFICATION Cand Screw Intermediate E12 E17 Med Skirt E26/50x39 Screw Terminal 1-2 3 Contact Med E26 Can DC Bay Disc Base Can SC Bay B15 Single Contact Pf Med Screw E26 2-Lug Sleeve B22d Mog Screw E39 3-Lug Sleeve B22-3 Med BiPost Med Side Pr 3 Contact Mogul E39D MedPf P28s Ext. Mog End Pr GX16d Mog Pf P40s Mogul BiPost G38 Mog End Pr GX16d For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B Incandescent Lamps LAMP LOCATOR A15 Med A15 2 & 3-Lug Slv A17 Med A19 Med A21 Med A21 3C Med A23 Med Lamp Shape A B8 B13 B10 Cand Cand Med Lamp Shape B C7 C7 Cand DC Bay CA8 Cand Lamp Shape C CA9 Med CA10 Cand CA10 Med Lamp Shape CA T8 Disc T6.5 DC Bay T8 Med T6.5 Inter G16.5 G16.5 G16.5 Cand DC Bay SC Bay G25 Med G16.5 Med G30 Med G30 Med Skrt G40 Med G40 Mog Lamp Shape G T20 T4 T4.5 T6 T6.5 T7 T7 T7 T8 T8 T8 T10 T10 T12 T14 T20 T24 T8 T8 Cand Cand Cand DC Bay Cand DC Bay Inter Cand DC Bay Inter SC Bay SC Pf Med Med Pf 3C Med Med Pf Mog BiPost Med BiPost Med Bi Post Lamp Shape M Lamp Shape T S6 S6 Cand DC Bay S6 Inter S8 SC Bay S8 SC Pf S11 Cand S11 DC Bay S11 Inter S11 Med S11 SC Bay S14 Med Lamp Shape S ER30 Med ER39 Med Lamp Shape ER BR30 Med BR40 Med F15 Med F10 Cand R20 Med R25 Med R30 Med Lamp Shape BR R40 Med PS30 Med PS30 Mog PS35 Mog E17 Med Lamp Shape RP R40 Med Skrt R40 Mog Lamp Shape E P25 3C Mog R52 Mog Lamp Shape P Lamp Shape R PAR20 PAR30 PAR36 Med NP Med NP Scrw Trm PS25 PS25 3C Mog Med RP11 SC Bay F20 Med Lamp Shape F R14 R14 SC Bay Inter M14 Med PS40 Mog PS40 Mog Pf PS52 Mog PAR46 Med Sid Pr PAR56 Scrw Trm PAR38 Skrt PAR38 PAR38 Med Skrt Med Sid Pr PAR56 Mog End Pr PAR56 Mog End Pr (6X16DEXT) PAR46 Scrw Trm PAR64 Scrw Trm PAR46 Mog End Pr PAR64 Ex Mog End Pr Lamp Shape PAR Lamp Shape PS For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B 1-3 Incandescent Lamps INTRODUCTION GE’s incandescent lamps trace their ancestry to the world’s first practical electric bulb, invented by Thomas Alva Edison, founder in 1879, of the company that became General Electric Company. More than a century of research and development later, the present range of GE incandescent lamps represents the state of the art of lamps for residential and commercial use, as well as special purpose lamps for decorative or display applications. In an incandescent lamp, light is generated by heating the filament to incandescence. The hotter the filament, the more efficient it is in converting electricity to light. However, when the filament operates hotter, its life is shortened so the design of each lamp is a balance between efficiency and life. This is why lamps of equal wattage may have different lumen ratings and different life ratings. Incandescent lamps of similar size are commonly available with different wattage ratings. The fixture wattage limit should not be exceeded. PROTECTION FROM MOISTURE When HRG (Hard Glass) appears in the Lamp Description column, the outer bulbs are made of special thermal-shock-resistant glass. However, sometimes external protection of the lamps is also needed to eliminate the chance of bulb breakage due to contact with water during operation. Footnotes will indicate when external protection is needed. Where HRG is not shown, the bulb glass is such that the lamps require protection from exposure to mist or condensation as well as direct contact with water during operation. RATED LIFE Values are based on a large number of representative lamps under controlled conditions. Individual lamps or groups of lamps may vary from the Rated Life shown. Rated Life is a median value of life expectancy – the total operating time at which under normal conditions 50% of any large group of initially installed lamps are expected to be still burning. GE Osram/Sylvania Phillips INCANDESCENT BRAND NAME CROSS-REFERENCE Reveal® Bug-Lite Cool Beam covRguard® Saf-T-Gard® Soft Pink Soft White Miser® Extended Service Plant Light Long Life Soft White Lumiline Party Light Survivor™ Watt-Miser® Watt-Miser® PAR Watt-Miser® Plus — Bug Lite Cool-Lux Safeline — Soft Pink Energy Saver Soft White Excel-Line® Spot-GRO Double Life™ Soft White Lumiline — — Super Saver® Super Saver Par® Super Saver Excel® — Bug-A-Way Cool Beam Silicone Coated — Softone Pastels Energy Saving Extended Service Agro-Lite Longer Life Soft White Philinea — Industrial Service Econ-o-Watt Econ-o-Par Extended Service ATTENTION: This brand-name cross-reference chart is provided only as a quick reference. Other lamp company brand listings may only represent a near equivalent, versus an identical match to GE brands. Individual lamp manufacturers’ product offerings and performance specifications should be consulted. Lamp performance may be affected by environmental conditions, and/or auxiliary equipment. 1-4 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B Incandescent Lamps GE REVEAL® LIGHT BULBS Superior light quality over regular incandescent that: • Produces “clean, beautiful light™” for more vibrant colors • Contains Neodymium glass that filters out dulling yellow rays • Is available in 40-100 watt A-Line • Also available for nearly every application from candle shapes to flood lights • A color enhanced full spectrum light bulb Reveal® A-line GE SURVIVOR™ A-LINE BULBS Built to last, even under many “rough” service conditions... • Five filament support design protects against early burnouts caused by bumps, jars and vibration • Longer life... lasts 3000 hours. 3-4 times longer than standard bulbs* • Popular wattages available • Economically priced • Best A-line choice for general commercial/industrial use Survivor ™ * Survivor bulbs provide a 300%-400% increase in life with 68%-75% of the light of ordinary bulbs. GE COVRGUARD® BULBS • Teflon® * coating is shatter and weather-resistant • Resists breakage from heat and thermal shock that can occur from water, sleet, snow, molten solder, and weld spatter • Wide choice of wattages and voltages • Rough service version available for extra tough conditions Uses: Construction sites, loading docks, string lighting, elevators, trouble light, metal fabricating, food processing areas, farms. ® covRguard * Teflon is a registered trademark of DuPont. GE LONG LIFE FLOODLIGHT OR SPOTLIGHT • 25% longer life than standard reflectors. Ideal for use in high ceilings and hard to reach track lighting. • Easy replacement – same length and width as standard R bulbs • Some lumen loss from standard reflectors (See listing for lumen values) • Available in 45w floodlight and 65w floodlight and spotlight Long Life BR30 Reflector Floodlight or Spotlight Uses: Down lighting, display lighting, accent lighting, wall washing. Wherever standard reflector bulbs are used. For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B 1-5 Incandescent Lamps HEADINGS IN THIS CATALOG SECTION The following terms and descriptions can help you when checking Incandescent lamp specifications and when ordering products. Within this product line, lamps are divided by wattage. Within wattage, lamps are listed alphabetically by bulb shape. Life-Hours: LCL in.: Distance between the center of the filament and the Light Center Length reference plane, in inches. Life (as defined by FTC Lamp Label Rules) is rated life in hours. (see page 1-26). Light Output-Lumens: Order Code: Light output (as defined by FTC Lamp Label Rules) is rated average lumens. MOL in.: It is important to use this five-digit code when ordering to ensure that you receive the exact product you require. Maximum Overall Length in inches. Color Temperature - Kelvins (K): “Warmth” or “Coolness” of the lamp, measured in Kelvins (K). The higher the temperature, the cooler the appearance of the light. Filament Design: Energy Used-Nominal Watts: Filaments are designated by a letter combination in which C is a coiled wire filament, CC is a coiled wire that is itself wound into a larger coil, and SR is a straight ribbon filament. Numbers represent the type of filament-support arrangement. Energy Used (as defined by FTC Lamp Label Rules). To estimate energy consumption (kWh), multiply watts x hours of use and divide by 1000. Shape: Approximate CBCP (Center Beam Candlepower): For reflector type lamps. Center Beam Candlepower is the intensity (candelas) at the center or maximum intensity of the beam. Approximate Beam Spread: Bulb shape followed by its size (the maximum diameter of the bulb expressed in eighths of an inch). For reflector type lamps. The total angle of the directed beam (in degrees) to where the intensity of the beam falls to 50% of the maximum value. Description: The lamp‘s identification code. Base: B Indicates that this is a reduced wattage option for lamps Case Quantity: The type of base. normally used in this application. Be sure to check wattage, lumens and life to determine which lamp is best suited to your needs. Number of product units packed in a case. Volts: Additional Information: Lamp data is based on operation at rated voltage. Shape Base Order Watts Code Description Typical application and/or other important information. Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information INCANDESCENT LAMPS 65 WATTS BR30 Med 65 26640 75R30/FL/65WM/A 120 30 2A, 5E, 9K Reflector - Amber 75 R30 / FL / 65WM / A Identifies the lamp’s wattage. Identifies the lamp’s shape. Identifies the lamp as a floodight. Identifies the lamp as a Watt-Miser® Identifies this lamp as amber colored. WHEN YOU DON’T KNOW THE LAMP DESCRIPTION 1. Identify the lamp wattage. 2. Measure bulb diameter using ruler in appendix section page A-1 to determine width in eighths of an inch. 3. Identify base type using table on page 1-2. 4. Find your lamp in the table containing the bulb wattage, then match the shape, size and base, which are all listed alphabetically. 1-6 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B Incandescent Lamps Shape Base Order Watts Code Description Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information INCANDESCENT LAMPS 3 WATTS S6 Cand 3 11098 3S6/5 24PK 130 24 C-7A 1.87 1.37 3000 4 16001 4C7/W CD/2 20572 4C7/S CD/4 20573 4C7/W/S CD/4 26222 4C7/PK-CD2 6PK 26223 4C7/BL-CD2 6PK 43050 4C7 CD/2 120 120 120 120 120 120 240 120 120 240 240 240 C-7A C-7A C-7A C-7A C-7A C-7A 2.12 2.12 2.12 2.12 2.12 2.12 3000 2000 2000 3000 3000 3000 6 11316 6S6 24PK 11329 6S6 11331 6S6 24PK 43397 6S6 BB 11367 6S6 TRAY 11577 6S6/3 15820 6S6 CARD2 11369 6S6 TRAY 11372 6S6 11374 6S6 6 11357 6S6DC 24PK 11592 6S6DC TRAY 11594 6S6/DC TRAY 11609 6S6DC 24PK 6 11660 6S6/7 TRAY 24PK 6 11764 6T41/2/1 12 24 30 32 120 120 120 130 145 155 75 120 130 145 120 130 24 240 24 24 240 240 240 240 240 240 24 240 240 24 24 100 C-2V C-2V C-2V C-2V C-7A C-7A C-7A C-7A C-7A C-7A C-7A C-7A C-7A C-7A C-7A C-7A 1.87 1.87 1.87 1.87 1.87 1.87 1.87 1.87 1.87 1.87 1.81 1.81 1.81 1.81 1.81 1.87 7 11779 7C7 TRAY 11815 7C7/W TRAY 11792 7C7 TRAY 120 240 C-7A 120 240 C-7A 130 240 C-7A 7.5 11847 7 1/2S TRAY 41267 7 1/2S/CW CARD 11848 7 1/2S TRAY 11922 7 1/2S/CW TRAY 120 120 130 130 10 12041 10S6/10 12050 10S6/10 24PK 10 12060 10S6/10DC 24PK 10 12249 10S11/79 10 12188 10S11N/F 12185 10S11N 230 24 C-7A 250 24 C-7A 230 24 C-7A 120 120 C-7A 120 120 C-7A 130 120 C-7A 11 Clear-Indicator 4 WATTS C7 Cand 2E 2E 2E 2E 2E 2E White-Long Life Night Light Standard Clear Night Light Standard White Night Light Long Life Pink Night Light Long Life Blue Night Light Long Life Clear Night Light 6 WATTS S6 Cand DC Bay T4.5 Inter Cand 1.37 1.37 1.37 1.37 1.37 1.37 1.37 1.37 1.37 1.37 1.43 1.43 1.43 1.43 1.06 1.31 1500 1500 1500 1500 1500 5000 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 50 50 50 45 41 23 41 41 41 41 45 41 41 41 41 42 Clear-Indicator Clear-Indicator Clear-Train Clear-Train Clear-Indicator. 12-Lamp Tray Clear-Signal Light Clear-Indicator Clear-Indicator. 12-Lamp Tray Clear-Indicator Clear-Indicator Clear-Indicator Clear-Indicator. 12-Lamp Tray Clear-Indicator. 12-Lamp Tray Clear-Indicator. 12-Lamp Tray Clear-Indicator. 12-Lamp Tray Clear-Indicator 2.12 2.12 2.12 3000 3000 3000 46 36 46 Clear-Indicator. 12-Lamp Tray White-Indicator. 12-Lamp Tray Clear-Indicator. 12-Lamp Tray 2.25 2.25 2.25 2.25 1400 1400 1400 1400 53 39 53 39 1500 1500 1500 1000 1000 1000 66 66 66 80 79 80 7 WATTS C7 Cand 7.5 WATTS S11 Med 240 240 240 240 C-9 C-9 C-9 C-9 2E Clear-12-Lamp Tray White Clear-12-Lamp Tray White-12-Lamp Tray 10 WATTS S6 Cand S11 DC Bay Cand Inter 1.87 1.87 1.87 2.25 2.31 2.31 1.37 1.37 1.87 1.56 1.62 1.62 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B Clear-Indicator Clear-Indicator Clear-Indicator Clear-Indicator Frost-Appliance Clear-Sign 1-7 Incandescent Lamps Shape Base Order Watts Code Description LCL Rated Life Lumens Hours Initial 2.5 2.5 2.5 2.5 3000 3000 3000 3000 76 76 2 1.25 2.37 1.25 1000 1000 200 180 2G Low Voltage, High Intensity Clear-Railway Signal Light, Filament in Multiple 3.56 3.5 3.5 3.5 2.62 2.25 2.37 2.25 3.5 3.5 3.06 3.06 3.06 2.25 2.25 2.25 5.62 1000 2500 2500 3000 2000 750 1000 400 1000 8000 2000 1500 1500 3000 180 110 115 110 120 115 138 120 144 90 107 102 102 100 100 100 120 5A I.F.-Train Soft White Inside Frost Clear-Sign Reflector Spot Clear Clear-Train Clear-Refrigerator, 12-Lamp Tray Frost-Locomotive Cab Clear-Sign. Group Replacement Clear-Exit Clear-Exit Clear-Exit. Blister Card Clear-Signal Light. Appliance Clear-Appliance, 12-Pack Clear-Appliance Clear-Aquarium 2B, 9C, 9J Security 3-Way, Soft White Case Filament Volts Qty. Design MOL Color Temp. K CBCP Beam Spread Footnotes Additional Information INCANDESCENT LAMPS (CONTINUED) 11 WATTS S14 Med 11 12575 11S14 12589 11S14/IF 12621 11S14/R 12632 11S14/Y 130 130 130 130 120 120 120 120 C-9 C-9 C-9 C-9 3.5 3.5 3.5 3.5 Clear-Sign I.F.-Sign Red-Sign Yellow-Sign 12-13.5 WATTS S8 S11 SC Bay SC Bay 12 10690 12S8/93T-6PK CD/2 13.5 12649 13/3 1/2 S11/95 12 240 C-2R 10 120 CC-6 C-12 15 WATTS A15 Med R14 S11 S14 SC Bay Cand DC Bay Med Med T6 Cand T7 Cand DC Bay Inter Med T10 15 12784 15A 41270 15A/W 24PK 12658 15A15 16215 15A15/CL/BB 15 33404 15R14SC/SP 15 13210 15S11/13 15 13188 15S11/3DC 15 13291 15S11/102 15 42590 15S14/FBB 11137 15S14/GR/CL/8 15 13390 15T6 13402 15T6 22114 15T6C-CD 17 13494 15T7C 17 35154 15T7DC CARD 17 35153 15T7N CARD 15 34407 15T10 24PK 34 120 130 130 12 120 75 120 34 130 120 145 145 120 120 120 120 120 120 120 120 120 120 120 240 120 120 60 60 120 120 240 240 24 C-9 C-9 C-9 C-9 CC-8 C-7A C-9 C-7A C-9 C-9 C-7A C-7A C-7A C-7A C-7A C-7A C-8 2.37 2.37 2.37 2.37 1.56 1.25 2.5 2.5 1.56 1.56 1.56 1.5 1.31 1.56 2500 15/135/150 WATTS A21 3C Med 15 23068 15/150/SECURITY 12PK 120 135 120 150 120 60 C-2R CC-8 5.25 3.87 1200 75 2080 2155 18 13655 18S11/1SC 13659 18/3 1/2S11SC 10 120 CC-6 10 120 CC-6 2.37 1.25 2.37 1.25 2000 1000 200 300 20 19549 20S11/1SC 20 34241 20T61/2DC/F 20 34272 20T61/2/F 10 120 CC-6 120 60 C-8 120 60 C-8 2.37 1.25 5.56 5.5 3000 5000 7000 90 90 2-Lug Slv 21.5 13644 18/3 5A15/5 10 120 CC-6 3.75 2.21 1500 235 75 120 C-9 3.46 2.5 1000 250 18 WATTS S11 SC Bay Clear-Railway Signal Light Clear-Railway Signal Light. C-12 Filament in multiple 20 WATTS S11 T6.5 SC Bay DC Bay Inter Railway Signal Light Frost-Exit Light Frost-Exit Light 21.5 WATTS A15 Clear-Railway Signal Light CC-6 Filament in multiple, 2-Lug Base 25 WATTS A15 1-8 Med 25 13744 25A15/RS 5A For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B I.F.-Train. Rough Service Incandescent Lamps Shape Base Order Watts Code Description Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information INCANDESCENT LAMPS (CONTINUED) 25 WATTS (CONTINUED) A19 Med 25 13769 25A 13784 25A 15064 25A/CL 24PK 16553 25A/TG-CD1 3PK 16555 25A/TR-CD1 3PK 47625 25A/TB-CD1 3PK 16333 25A/TP-CD 6PK 47627 25A/TPK-CD1 3PK 16335 25A/TY-CD 6PK 22730 25A/TPK 6PK 22731 25A/TP 6 PK 22732 25A/TE 6PK 33486 25A/RS 24PK 37577 25A/B 24PK 37578 25A/G 24PK 37579 25A/R 24PK 37793 25A/Y 24PK 40320 25A/O-24PK 41272 25A/W 24PK 46645 25A/SG CD/PQ1/5 49724 25A/TB 6PK 49725 25A/TG 6PK 49727 25A/TR 6PK 49728 25A/TY 6PK 13992 25A/CL 35613 25A 13879 25A PAR36 Scrw Term 25 14553 25PAR36 14554 25PAR36/NSP 14555 25PAR 36WFL 14556 25 PAR36 VWFL PAR46 Scrw Term 25 14562 25PAR46 R14 Inter 25 39156 25R14N 18230 25R14N SC Bay 25 33405 25R14SC/SP S11 Cand 25 14585 25S11/2C 14594 25S11/5C SC Bay 25 14575 25S11/4SC T6.5 DC Bay 25 14676 25T6 1/2DC 14678 25T61/2/DC 14685 25T61/2DC/F Inter 25 14639 25T6 1/2 14641 25T61/2 14668 25T61/2/F T7 DC Bay 25 14741 25T7DC Inter 25 10692 25T7N-CD 6PK 14791 25T7N T8 Cand 25 14809 25T8C T10 Med 25 14880 25T10 24PK 14866 25T10 12 34 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 130 130 250 6 12 12 12 6 120 130 12 120 120 10 120 130 130 120 130 130 120 120 120 120 120 130 120 120 120 12 12 12 24 12 24 120 120 120 24 24 24 24 24 24 120 25 120 120 120 120 120 120 120 12 12 12 12 12 120 120 120 120 120 120 60 60 60 60 60 60 60 240 60 60 192 120 C-6 C-9 CC-6 C-9 C-9 C-9 C-9 C-9 C-9 C-9 C-9 C-9 C-17 C-9 C-9 C-9 C-9 C-9 CC-6 CC-6 C-9 C-9 C-9 C-9 CC-6 CC-6 C-17A C-6 C-6 C-6 C-6 C-6 CC-2V CC-2V CC-8 C-7A C-7A CC-6 C-8 C-8 C-8 C-8 C-8 C-8 C-7A C-7A C-7A C-7A C-8 C-8 3.87 3.87 4.25 3.87 3.87 3.87 3.87 3.87 3.87 3.87 3.87 3.87 3.87 3.87 3.87 3.87 3.87 3.87 4.25 4.25 3.87 3.87 3.87 3.87 4.25 4.25 3.87 2.75 2.75 2.75 2.75 3.75 2.56 2.56 2.62 2.25 2.25 2.37 5.56 5.56 5.56 5.5 5.5 5.5 2.25 2.25 2.25 2.62 5.62 5.62 2.56 2.56 2.5 2.37 2.37 2.37 2.37 2.37 2.37 2.37 2.37 2.37 2.56 2.37 2.37 2.37 2.37 2.37 2.5 2.5 2.37 2.37 2.37 2.37 2.5 2.5 2.56 1.43 1.56 1.25 1.31 1.56 1.56 1.5 1000 1000 2500 2000 2000 2000 2000 2000 2000 2000 2000 2000 1000 2500 2500 2500 2500 2500 2500 1500 2000 2000 2000 2000 2500 2500 1000 1000 2000 2000 2000 1000 1500 1500 2000 500 500 1000 1000 1000 1000 1000 1000 1000 200 200 200 200 1000 1000 378 390 215 5A 5A 190 2A, 5E 210 215 215 220 130 150 150 150 140 5A 3000 19700 2600 360 160 55000 5 9 55 5E 5E 260 260 360 220 244 240 220 244 240 195 195 195 195 248 248 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B Inside Frost I.F.-Train Clear Transp. Green-Party Light Transp. Red-Party Light Transp. Blue-Party Light Transp. Purple-Party Light Transp. Pink-Party Light Transp. Yellow-Party Light Transp. Pink-Party Light Transp. Purple-Party Light Transp. Teal-Party Light I.F.-Rough Service Blue Green Red Yellow Orange Soft White Stained Glass Transp. Blue-Party Light Transp. Green-Party Light Transp. Red-Party Light Transp. Yellow-Party Light Clear Inside Frost Inside Frost Pin Spot. Filament Shield Narrow Spot-Filament Shield Wide Flood-Filament Shield Very Wide Flood. Filament Shield Pin Spot. Filament Shield Reflector-Light Inside Frost Reflector-Light Inside Frost Reflector Spot, Light I.F. Clear-Medical Spot Reprographic-Frost. Printer Clear-Railway Signal Light Clear-Appliance. Scale Illuminator Clear-Appliance. Scale Illuminator Frost-Appliance Scale Illuminator Clear-Showcase Clear-Showcase Frost-Showcase Clear-Appliance Clear-Appliance Clear-Appliance Clear-Microwave Clear-Showcase Clear-Showcase 1-9 Incandescent Lamps Shape Base Order Watts Code Description Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information INCANDESCENT LAMPS (CONTINUED) 27 WATTS R20 Med 27 47681 27R20/SP/LLPQ1-6 120 30 14129 30A15 15291 30A15/CL 19358 30A15/8 30 14891 30R20/1-6PK 46848 30R20/1 46849 30R20/6 30 15012 30S11DC 17948 30S11DC/RS 30 15029 L30 15071 L30/W 30 CC-6 B 3.93 2500 130 120 C-9 130 120 C-9 130 120 C-9 120 30 CC-6 130 30 C-9 130 30 C-9 3.5 2.37 3.5 2.37 3.5 2.37 3.93 3.93 3.93 5000 5000 8000 2000 2000 6000 215 215 180 200 200 145 75 120 C-7A 75 120 C-9 120 24 C-8 120 24 C-8 2.37 1.25 2.37 1.25 17.75 17.75 500 2000 1500 1500 350 300 230 210 120 120 120 120 120 120 60 C-2R CC-8 5.25 3.87 1200 60 C-2R 5.25 3.875 1200 305 995 1300 220 740 960 Long Life Reflector - Indoor Spotlight 30 WATTS A15 Med R20 Med S11 DC Bay T8 Disc 5B, 9K 9D 9D I.F. Changing Message Sign Clear Changing Message Sign I.F. - Sign Indoor Reflector Indoor Reflector - Light I.F. Reflector - Light I.F. - Flashing Message Sign Clear-Train Marker Control, BDTH Clear-Train Clear-Lumiline White-Lumiline 30/70/100 WATTS A21 3C Med 30 41273 30/100 12PK 70 100 30 48711 30/100RVL PQ1/12 70 100 2B, 9C, 9J Soft White. 3-Way 2B, 9C, 9J Reveal® 3-Way 33 WATTS A19 Med 33 42626 33A19/5 130 120 C-9 3.87 2500 270 34 12612 40A/34WM 34 12620 40A/34WM 30 34 13009 40A/34WMP/99 30 120 120 CC-6 130 120 CC-6 120 130 120 CC-6 120 4.43 3.12 4.43 3.12 2000 2000 5400 2500 6800 380 365 270 360 265 40 15199 40A15 120 120 C-9 3.5 2.37 1500 415 15206 40A15 CARD 12PK 120 60 C-9 3.5 2.37 1500 415 20451 40A15/CF CD2 20452 40A15/W/CF CD2 21188 40A15 CD/2 120 120 120 60 C-9 60 C-9 60 C-9 3.5 2.37 3.5 2.37 3.5 2.37 1500 1500 1500 415 355 415 27451 40A15/F 120PK 120 120 C-9 3.5 2.37 1500 355 27495 40A15/F/CD 120 60 C-9 3.5 2.37 1500 355 45729 40A15/F CD2 120 60 C-9 3.5 2.37 1500 355 46887 40A15CF/STG CD2 48696 40A15/CF/RVL CD2 120 120 30 30 C-9 3.5 2.37 1500 3.5 2.375 1500 400 320 48697 40A15WCF/RVL CD2 120 30 C-9 3.5 2.375 1500 260 48706 40A15/RVL CD2 120 30 C-9 3.5 2.375 1500 320 Clear-Changing Message Sign. Group Replacement 34 WATTS A19 Med 4.43 3.12 B B B Watt-Miser®-Diffuse Coating Watt-Miser®-Diffuse Coating (Ratings @120 volts) Watt-Miser® Plus-Diffuse Coating. Long Life, BB (Ratings @120 volts) 40 WATTS A15 1-10 Med For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B Clear-Appliance and Oven Service. Vibration Resistant Clear-Appliance and Oven Service. Vibration Resistant Clear-Ceiling Fan. Vibration Resistant White-Ceiling Fan. Vibration Resistant Clear-Appliance and Oven Service. Vibration Resistant Frosted-Appliance and Oven Service. Vibration Resistant. Frosted-Appliance and Oven Service. Vibration Resistant. Frosted-Appliance and Oven Service. Vibration Resistant. Clear, Saf-T-Gard®, Ceiling Fan Reveal® Clear-Ceiling Fan. Vibration Resistant Reveal® White-Ceiling Fan. Vibration Resistant Reveal® Clear-Appliance and Oven Service. Vibration Resistant. Incandescent Lamps Shape Base Order Watts Code Description Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information INCANDESCENT LAMPS (CONTINUED) 40 WATTS (CONTINUED) A19 A21 R14 Med R16 S11 Med Inter Med Med Inter T6.5 Inter T8 Disc T10 Med Med 40 12311 40A/CL 24PK 13255 40A 48PK 13257 40A/W 48PK 48687 40A/RVL 48PK 81869 40A/CL/RVL 24PK 40 34034 40A 36 40 34125 40A/CL 36 40 40323 40A/S-130V-24PK 36 40 15554 40A/TS 40 25777 40R14/N/CD 40 25776 40R14/CD 40 25781 40R16/CD 40 15734 40S11N/1/F 35156 40S11N/1/CD 12PK 40 15740 40T6 1/2/2 15742 40T61/2/2F 40 15804 L40 15839 L40/W 40 15754 40T8 40 15852 40T10 15892 40T10/F 15854 40T10 120 120 120 120 120 130 120 130 120 130 120 130 120 120 120 120 120 120 120 120 120 120 120 120 130 45 20330 45R/FL/MI/1 6PK 26804 45R30/FL/LL 45 47682 45R20/SP/LLPQ1-6 120 120 120 50 16201 50A19/RS 14727 50A/RS/CVG 24PK 120 144 144 144 120 120 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 4.43 4.43 4.43 4.43 4.43 4.43 3.12 3.12 3.12 3.12 3.12 3.125 4.37 2.43 2.68 2.18 3.37 2.31 1.62 2.31 1.62 5.5 5.5 11.75 11.75 11.75 5.62 5.62 5.62 1500 1000 1000 1000 1000 1000 2600 1500 4000 3000 5500 2000 1500 1500 1500 500 500 750 750 1500 1500 1000 1000 1000 1000 5.37 5.37 3.31 2000 2500 2500 485 450 75 120 C-9 120 24 C-17A 3.87 2.5 3.87 2.56 1000 1000 545 480 2A, 5A 2A, 9L, 9M 33495 50A/RS 24PK 15995 50A 16147 50A/RS 16317 50A19 50 10686 50A21/RV 6PK 120 24 C-17A 250 120 C-17A 250 120 C-22 300 120 C-17A 12 48 C-6 3.87 3.87 3.87 3.87 4.87 2.56 2.56 2.56 2.56 3.43 1000 1000 1000 1000 1000 490 490 470 460 875 2A, 5E 16366 50A21 16385 50A21 16390 50A21 50 44429 50ER30 47878 50ER30/PK 11823 50ER30 50 16535 50/50P25/28 12 120 C-6 30 120 C-9 34 120 C-9 120 24 CC-6 120 24 CC-6 130 24 CC-6 120 60 C-5 C-9 4.87 4.87 4.87 6.25 6.25 6.25 5.06 3.43 3.43 3.43 1000 1000 1000 2000 2000 1500 750 875 805 805 525 480 525 400 120 CC-6 4.43 3.12 24 C-9 4.43 3.12 120 30 30 30 120 240 60 60 24 12 24 120 120 120 C-9 CC-2V CC-2V CC-6 C-9 C-9 C-8 C-8 C-8 C-8 C-23 C-8 C-8 C-8 480 505 490 360 370 495 365 480 345 330 245 380 9D 440 440 420 420 325 295 430 420 415 420 2G, 5E 2G, 5E Crystal Standard Soft White Reveal® Soft White Reveal® Clear Inside Frost (Ratings @ 120 volts.) Clear (Ratings @ 120 volts.) Survivor™ LongLife, I.F., Vibration Resistant, BB (Ratings @ 120 volts.) Clear-Traffic Signal, BDTH Indoor Reflector Indoor Reflector Indoor Reflector Frost Clear-12-Card Pack Clear-Refrigerator Frost-Appliance Clear-Lumiline White-Lumiline Clear-Showcase Clear-Showcase Frost-Showcase Clear-Showcase 45 WATTS BR30 Med R20 Med 30 CC-6 30 CC-6 30 CC-6 300 5E, 9K B 2A, 2A, 5E, 9K B B 2A, 5E, 9K Reflector Flood Reflector Flood-Long Life Long Life Indoor Spotlight 50 WATTS A19 A21 Med Med ER30 Med P25 3C Mog 3.31 2A, 5E 5A 690 690 5A 5A 5A 2A, 2B, 5E 2A, 2B, 5E 2A, 2B, 5E For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B I.F.-Rough Service, Train Inside Frost-covRguard® Rough Service, BB, Teflon® Coated I.F.-Rough Service Inside Frost I.F.-Rough Service Inside Frost Recreational Vehicle and Marine Inside Frost Inside Frost I.F.-Train I.F.-Train Elliptical Reflector, Light I.F. Elliptical Reflector-Pink Elliptical Reflector, Light I.F. Clear-2-filament Marine Running Light, BB 1-11 Incandescent Lamps Shape Base Order Watts Code Description Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information INCANDESCENT LAMPS (CONTINUED) 50 WATTS (CONTINUED) PAR36 Scrw Term 50 11468 50PAR36WFL/4 12892 50PAR36VNSP 16540 50PAR36/NSP 16541 50 PAR 36 WFL 16542 50 PAR 36 VWFL R20 Med 50 14888 50R20/PL/1 6PK 14896 50R20/1 6PK 20368 50R20/TWIN 22752 50R20/BLB 6PK 12 12 12 12 12 120 120 120 120 12 12 12 12 12 30 30 30 6 C-6 C-6 C-6 C-6 C-6 CC-6 CC-6 CC-6 CC-6 2.75 2.75 2.75 2.75 2.75 3.93 3.93 3.93 3.93 4000 2000 2000 2000 2000 2000 2000 2000 1000 46854 50R20/HP/1 48691 50R20/RVL PQ1/6 46851 50R20/1 46852 50R20/6 120 120 130 130 CC-6 30 CC-6 30 CC-6 30 C-9 3.93 3.93 3.93 3.93 2000 2000 2000 6000 410 400 130 130 115 30 CC-6 30 CC-6 24 C-5 C-9 3.93 3.93 5.31 3 2000 2000 750 400 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 60 CC-8 CC-8 5.25 3.87 1200 30 CC-8 C-2R 5.25 3.87 1000 60 CC-8 CC-8 5.25 3.87 1200 30 CC-8 CC-8 5.25 3.87 1200 60 CC-8 CC-8 5.25 3.875 1200 60 CC-8 CC-25 5.25 3.87 1200 620 3335 3955 120 CC-8 120 CC-8 4.43 3.12 4.43 3.12 120 CC-8 4.43 3.12 120 CC-8 4.43 3.12 1330 1000 2600 2500 6800 1000 2600 730 710 530 640 480 720 540 B B B B Watt-Miser®-Diffuse Coating Watt-Miser®-Diffuse Coating (Ratings @ 120 volts.) Watt-Miser® Plus, Diffuse Coating, LongLife, BB (Ratings @ 120 volts.) Watt-Miser®-Clear (Ratings @ 120 volts.) 54 17960 60A21/54WM/TS 120 C-11V 4.37 2.43 8000 530 17961 60A21/54WM/TS 120 C-11V 4.37 2.43 8000 530 B B Watt-Miser®, Clear-Traffic Signal, Burn BDTH, BB, Krypton Watt-Miser®, Clear-Traffic Signal, Burn BDTH, BB, Krypton T12 3C Med 46853 50R20/PK/1 48038 50R20/FUS 50 16726 50/50T12 300 330 330 330 330 720 19000 11000 900 600 410 410 510 510 6 10 55 2A, 5E, 9K 2A, 5E, 9K 2A, 5E, 9K 2A, 2F, 5B, 7A, 7C, 9K Wide Flood, Filament Shield Very Narrow Spot, Filament Shield Narrow Spot, Filament Shield Wide Flood, Filament Shield Very Wide Flood. Filament Shield Reflector Plant Light Reflector-I.F. Reflector Twin Pk. Blacklight Reflector Reflector, Hot Pink Reveal® Indoor Reflector - Light I.F. Reflector - Light I.F. - Flashing Message Sign Indoor Reflector - Pink Reflector, Fusia Clear-2-filament Marine Running Light, BB 510 50/100/150 WATTS A21 3C Med 50 14057 50/150/SSW 12PK 100 150 50 22886 50/150A/RL/SW6PK 100 150 50 41280 50/150 12PK 100 150 50 41362 50/150 TWIN 6PK 100 150 50 48712 50/150RVL PQ1/12 100 150 650 1550 2200 495 1425 1920 615 1540 2155 615 1540 2155 450 1150 1600 2B, 9C, 9J Super Soft White, 3-Way 2B, 9C, 9J Soft White-Reader Light™ 3-Way 2B, 9C, 9J Soft White. 3-Way 2B, 9C, 9J 2B, 9C, 9J Reveal® 3-Way 2B,9C, 9J Soft White, 3-Way 50/200/250 WATTS A21 3C Med 50 19445 50/250/1 12PK 200 250 120 120 120 52 WATTS A19 Med 52 12615 60A/52WM 52 12623 60A/52WM 46 52 13012 60A/52WMP/99 46 52 13555 60A/52WM/CL 46 120 130 120 130 120 130 120 54 WATTS A21 1-12 Med For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B Incandescent Lamps Shape Base Order Watts Code Description Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information INCANDESCENT LAMPS (CONTINUED) 55 WATTS A19 Med 55 11904 55A/SW/MI 48PK 120 144 CC-8 4.43 3.12 1000 800 60 14029 60A15/W/CF-CD2 17759 60A15/CF CD2 120 120 60 C-9 60 C-9 3.5 2.37 3.5 2.37 1500 1500 650 650 120 120 30 C-9 30 C-9 3.5 2.37 1500 3.5 2.375 1500 650 480 120 120 CC-8 120 24 CC-6 120 24 C-9 120 120 CC-6 120 24 CC-6 120 24 C-9 120 24 C-9 4.43 4.43 4.43 4.43 4.43 4.43 4.43 840 850 25905 60A/BLB 6PK 120 4.43 1000 39322 60A/CL 24PK 40324 60A/S-120V-24PK 120 120 CC-6 120 24 C-9 4.43 3.12 4.43 3.12 1000 3000 870 600 120 120 120 120 120 120 120 120 130 120 130 120 230 120 120 4.43 4.43 4.43 4.43 4.43 4.43 4.43 4.43 4.43 865 840 550 820 630 812 630 650 850 640 600 460 585 B Soft White, Miser® 60 WATTS A15 Med 46888 60A15CF/STGPQ2/6 48698 60A15/CF/RVL CD2 A19 A21 Med Med 60 14052 60A/SSW-24PK 14414 60A/CVG 24PK 16364 60A/BLB-CD 20326 60A/SPK 24PK 22361 60A/COMM 24PK 22384 60A/GD 24PK 23097 60A/GD CD 41026 60A 48PK 41028 60A/W 48PK 41284 60A/Y 24PK 41285 60A/W/LL 24PK 41624 60A/PL 6PK 46845 60A/W/STG PQ2/10 48688 60A/RVL 48PK 81639 60A/CL /RVL 24PK 60 16783 60A 53 60 40325 60A/S-130V-24PK 53 60 17122 60A21 16997 60A21/B 17027 60A21/R 17968 69A21/60WM/TS 17969 69A21/60WM/TS PAR46 Scrw Term 60 17212 60PAR/2/R T8 Disc 60 17226 L60 17266 L60/W T10 Med 60 17292 60T10/64 24PK 30 C-9 144 144 120 120 30 100 144 120 120 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-8 CC-6 CC-6 3.12 3.12 3.12 3.12 3.12 3.12 675 855 635 635 2A, 2F, 5B, 7A, 7C, 9K C-17A C-9 C-9 C-11V 4.37 2.75 4.87 4.87 4.37 2.43 1000 1000 1000 1500 1000 1000 1000 1000 1000 2600 3000 8300 1000 1000 1000 8000 120 C-11V 4.37 2.43 8000 610 480 450 740 24 C-9 120 120 120 120 3.12 3.12 3.12 3.12 3.12 3.12 3.12 3.12 3.12 1000 1000 1000 1000 1000 3000 3000 4.43 3.12 38 12 120 24 120 12 120 192 CC-2V C-8 C-8 C-8 3.75 17.75 17.75 5.62 800 1500 1500 1000 120 120 120 120 120 120 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 5.37 5.37 5.37 5.37 5.37 5.37 2000 2000 2000 2000 2000 2000 5E 2B 2B 610 White, Ceiling-Fan, Vibration-Resistant Clear-Ceiling Fan and Appliance, Vibration Resistant Ceiling Fan Saf-T-Gard® Reveal® Clear-Ceiling Fan. Vibration Resistant Super Soft - Soft White Inside Frost-covRguard®, Teflon® Coated Black Light; Carded Soft Pink Inside Frost Light I.F.-Garage Door, Vibration Resistant Light I.F. Garage Door, Vibration Resistant, Carded Black Light Clear Survivor™ LongLife I.F., Vibration Resistant, BB Standard Soft White Yellow Bug-Lite Soft White-LongLife Plant Light Soft White Saf-T-Gard® Reveal® Soft White Reveal® Clear Inside Frost (Ratings @ 120 volts.) Survivor™ LongLife I.F., Vibration Resistant, BB (Ratings @ 120 volts.) Inside Frost Blue Red Watt-Miser®-Clear, Traffic Signal, Burn BDTH, BB Watt-Miser®-Clear, Traffic Signal, Burn BDTH, BB Red Lens-Train Warning Clear-Lumiline White-Lumiline Clear-Showcase, BDTH 65 WATTS BR30 Med 65 18011 65R/FL/MI/TWIN 20331 65R/FL/MI/1 6PK 20332 65R/SP/MI/1 6PK 20996 65R30/PL/1 6PK 22714 65R30/FL/COMM 12PK 26641 65R30/FL/B 6 30 30 30 12 30 755 755 755 755 2A, 5E, 9K 2A, 5E, 9K 2A, 5E, 9K 2A, 5E, 9K 2A, 5E, 9K 2A, 5E, 9K For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B Reflector Flood Twin Pack Reflector Flood Reflector Reflector -Plant Light, BB Reflector Flood 12 Pack Reflector - Blue 1-13 Incandescent Lamps Shape Base Order Watts Code Description Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information INCANDESCENT LAMPS (CONTINUED) 65 WATTS (CONTINUED) BR30 Med 65 26642 65R30/FL/G 26645 65R30/FL/Y 26803 65R30/FL/PK 26805 65R30/FL/LL 26806 65R30/SP/LL 41837 65R30/SP/HP 46858 65R30/FL/CVG 47723 65R30FL/STGPQ1/6 48692 65R/FL/RVL PQ1/6 46855 65R30/FL 46856 65R30/SP 46857 65R30/FL/PK 48039 65R30SP/FUS BR40 Med 65 14016 65R40/FL/MI 6PK 47683 65R40/FL/LLPQ1-6 46861 65R40/FL 87904 65R40FL/RVL-TP6 PAR38 Med Sid Pr 65 80314 75PAR/3FL/65WM 80320 75PAR/3SP/65WM 120 120 120 120 120 120 120 120 120 130 130 130 130 120 120 130 120 120 120 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 12 12 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 5.37 5.37 5.37 5.37 5.37 5.37 5.37 5.37 5.37 5.37 5.37 5.37 5.37 6.56 6.56 6.56 6.56 4.3 4.3 2000 2000 2000 2500 2500 2000 2000 2000 2000 2000 2000 2000 2000 2000 2500 2000 2000 2000 2000 2A, 5E, 9K 2A, 5E, 9K 2A, 5E, 9K 2A, 5E, 9K 2A, 5E, 9K 120 CC-8 120 CC-8 4.43 3.12 4.43 3.12 120 CC-8 4.43 3.12 1030 1000 755 910 685 635 635 B B B Watt-Miser®-Diffuse Coating Watt-Miser®-Diffuse Coating (Ratings @ 120 volts.) Watt-Miser® Plus-Diffuse Coating (Ratings @ 120 volts.) Clear-Traffic Signal, BDTH Clear-Traffic Signal, BDTH 725 725 725 725 730 700 675 675 2675 2675 1750 5900 30 14 B B 2A, 2B, 5E, 9K 2A, 2B, 5E, 9K 2A, 2B, 5E, 9K 2A, 2B, 5E, 9K 1A, 2A, 2B 1A, 2A, 2B Reflector - Green Reflector - Yellow Reflector - Pink Long Life Reflector - Flood Long Life Reflector Indoor Reflector, Hot Pink Reflector - covRguard® Teflon® Coated Indoor Floodlight - Saf-T-Gard® Reveal® Watt-Miser® - Reflector Watt-Miser® - Reflector Watt-Miser® - Reflector - Pink Indoor Reflector, Fusia Reflector Flood Long Life Reflector - Indoor Floodlight Watt-Miser® - Reflector - I.F. Reveal® Reflector Flood Compact Flood Compact Reflector 67 WATTS A19 A21 Med Med 67 12617 75A/67WM 67 12624 75A/67WM 60 67 13018 75A/67WMP/99 60 67 38551 67A21/TS 38553 67A21/TS 120 130 120 130 120 120 130 120 C-9 120 C-9 4.37 2.43 4.37 2.43 1000 1000 2600 2500 6800 8000 8000 69 17323 69A21/TS 17325 69A21/TS 120 120 C-9 130 120 C-9 4.37 2.43 4.37 2.43 8000 8000 675 675 B B Clear-Traffic Signal, BDTH Clear-Traffic Signal, BDTH 70 11905 70A/SW/MI 48PK 120 144 CC-8 4.43 3.12 750 1125 B Soft White, Miser® 70 15846 80/250A/RL/SW 6PK 170 240 120 120 120 5.75 4.31 1000 1000 1000 800 2800 3600 75 10428 75A/CL 24PK 22364 75A/COMM 24PK 41030 75A 48PK 41032 75A/W 48PK 41287 75A/W/LL 24PK 48689 75A/RVL 48PK 81870 75A/CL/RVL 24PK 75 17347 75A 67 75 40328 75A/S-130V-24PK 67 120 120 120 120 120 120 120 130 120 130 120 4.43 4.43 4.43 4.43 4.43 4.43 4.43 4.43 750 750 750 750 1125 750 750 750 1950 3000 8300 1200 1180 1190 1170 1125 830 885 1170 885 815 615 69 WATTS A21 Med 70 WATTS A19 Med 70/170/240 WATTS A21 3C Med 30 C-2R CC-8 2B, 2I, 9J Soft White- Reader Light™ 3-Way 75 WATTS A19 1-14 Med 120 24 144 144 120 144 120 120 CC-6 CC-6 CC-6 CC-6 CC-6 CC-8 CC-6 CC-6 24 C-9 3.12 3.12 3.12 3.12 3.12 3.12 3.12 3.12 4.43 3.12 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B Clear Inside Frost Standard Soft White Soft White-LongLife Reveal® Soft White Reveal® Clear Inside Frost (Ratings @ 120 volts.) Survivor™ LongLife I.F. Vibration Resistant (Ratings @ 120 volts.) Incandescent Lamps Shape Base Order Watts Code Description Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information INCANDESCENT LAMPS (CONTINUED) 75 WATTS (CONTINUED) A21 Med 12 120 C-6 120 60 C-17 120 30 C-17 120 30 C-17 5.25 5.25 5.25 5.25 3.81 3.81 3.81 3.81 1000 1000 1000 1000 1500 750 740 740 75 17527 75A/RS 60PK 67 ER30 Med 75 37044 75ER30 42850 75ER30 PAR38 Med Sid Pr 75 80319 75PAR/3SP/MINE 80316 75PAR/3FL/MINE PAR46 3 Prong 75 36473 75PAR46/TS R20 Med 75 11320 75R20 6PK R30 Med 75 22748 75R30/BLB 6PK 130 120 120 130 120 120 120 120 120 60 C-17 5.25 3.81 24 24 12 12 12 60 6 6.25 6.25 4.3 4.3 3.87 3.93 5.37 1000 2600 2000 2000 2000 2000 6000 2000 1000 740 560 850 850 765 765 700 650 T10 120 120 24 C-23 24 C-23 11.87 11.87 1000 1000 800 800 CC-6 CC-6 CC-6 CC-6 CC-6 5.31 5.31 5.31 5.31 5.31 2000 2000 2000 2000 2000 75 12 CC-6 2.75 1500 810 90 12618 100A/90WM 90 12625 100A/90WM 80 90 13023 100A/90WMP/99 80 90 17972 100A21/90WM/TS 120 130 120 130 120 125 120 CC-8 120 CC-8 4.43 3.12 4.43 3.12 120 CC-8 4.43 3.12 120 C-11V 4.37 2.43 1000 1000 2600 2500 6800 8000 1465 1440 1095 1260 960 1040 90 46870 90R40/FL 14017 90R40/FL/MI 6PK 130 120 30 CC-6 30 CC-6 6.563 6.56 2000 2000 1050 1100 Watt-Miser -Diffuse Coating B Watt-Miser -Diffuse Coating B (Ratings @ 120 volts.) Watt-Miser Plus-Diffuse Coating. B LongLife, (Ratings @ 120 volts.) Watt-Miser -Clear. Traffic Signal. B Burn BDTH, Krypton Watt-Miser - Reflector - I.F. B 2A, 2B, 5E, 9K Reflector Flood B 95 11906 95A/SW/MI 48PK 120 144 CC-8 4.43 3.12 750 1610 B 120 120 120 120 120 120 4.43 4.43 4.43 4.43 4.43 4.43 3.12 3.12 3.12 3.12 3.12 3.12 750 750 1000 750 750 3000 1690 1710 1330 1690 1730 1190 4.43 3.12 4.43 3.12 4.43 3.12 750 750 1125 1710 1690 1600 Med 75 17482 75A21 18274 75A/RS 12PK 46895 75A/RS/STG PQ1/6 47263 75A/RS/CVG-6PK 75 17749 75T10/1 17754 75T10/45 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 C-9 5A 2A, 5E 2A, 5E 2A, 5E 2A, 2B, 5E 2A, 2B, 5E 1A, 2A, 2B, 1A, 2A, 2B, 1200 1200 2725 2725 1750 33 2A, 5E, 9K 2A, 2F, 5B, 7A, 7C, 9K Inside Frost I.F. Rough Service Rough Service, Saf-T-Gard® Inside Frost - covRguard® Rough Service, Teflon® Coated I.F. Rough Service (Ratings @ 120 volts) ER-Elliptical Reflector, Light I.F. ER-Elliptical Reflector, Light I.F. 9N Mine Reflector 9N Mine Flood Traffic Signal Reflector , I.F. Reflector Black Light Frost-Showcase Clear-Showcase 85 WATTS PAR38 Med Skirt 85 20945 85PAR/FL/BG 6PK 13465 100PAR/B/85WM 6PK 13472 100PAR/R/85WM 6PK 13473 100PAR/Y/85WM 6PK 13474 100PAR/G/85WM 6PK 120 120 120 120 120 6 6 6 6 6 B B B B 1A, 2A, 2B 1A, 2A, 2B 1A, 2A, 2B 1A, 2A, 2B 1A, 2A, 2B Yellow-Bug-Lite, BB Powder Coated - Blue, BB Powder Coated - Red, BB Powder Coated - Yellow, BB Powder Coated - Green, BB 88 WATTS PAR36 Scrw Term 88 39817 88PAR36/FL Projector-Train Warning 90 WATTS A19 A21 Med Med BR40 Med ® ® ® ® ® 95 WATTS A19 Med Soft White Miser® 100 WATTS A19 Med 100 14056 100A/SSW-24PK 17995 100A/LHT/IF 20328 100A/SPK 24PK 22366 100A/COMM 24PK 39321 100A/CL 24PK 40329 100A/S-120V-24PK 41034 100A 48PK 41036 100A/W 48PK 41289 100A/W/LL 24PK 120 120 120 24 120 24 CC-8 CC-8 CC-8 CC-8 CC-8 C-9 120 144 CC-8 120 144 CC-8 120 120 CC-8 2B 2B For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B Super Soft - Soft White Inside Frost, Left-Hand Medium Base Soft Pink Inside Frost Clear Survivor™-I.F., Long Life, Vibration Resistant BB Standard Soft White Soft White-Long Life 1-15 Incandescent Lamps Shape Base Order Watts Code Description Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information INCANDESCENT LAMPS (CONTINUED) 100 WATTS (CONTINUED) A19 A21 Med Med 100 41291 100A/Y 24PK 46846 100A/W/STGPQ2/10 48690 100A/RVL 48PK 81871 100A/CL/RVL 24PK 100 17933 100A 89 100 40330 100A/S-130V-24PK 89 100 17525 100A21/SBIF 60PK 18275 100A/RS 12PK-5 47261 100A/RS/STGPQ1/6 47262 100A/RS/CVG-6PK 18365 100A21/TS 100 17522 100A/RS 60PK 89 100 18221 100A21 89 100 21315 100A21/99 60PK 89 100 17515 100A 60PK 17516 100A 60PK 17524 100A/RS 60PK 17517 100A 60PK A23 Med 100 18512 100A23 17904 100A 18449 100A23/IF 18542 100A23/20 100 33456 100A23/VS 89 G16.5 DC Bay 100 18721 100G16.5/29DC PAR38 Med Sid Pr 100 80323 100PAR38/FL R30 Med 120 120 120 120 130 120 130 120 120 120 120 120 120 100 144 120 120 CC-8 CC-8 CC-8 CC-8 CC-8 3.87 3.81 3.81 3.81 1000 750 750 750 750 1950 3000 8300 1000 1000 1000 1000 900 1624 1260 1300 1680 1275 1170 880 1400 1160 1230 1230 130 120 C-9 4.37 2.43 3000 1280 130 120 130 120 130 120 230 250 250 277 12 34 120 120 130 120 120 12 60 C-17 5.25 3.81 60 CC-6 5.25 3.87 60 CC-6 5.25 3.87 1060 800 1690 1285 1420 1080 1280 1200 960 1250 1750 2160 1600 1530 1340 1020 1660 1400 24 C-9 60 60 30 30 CC-6 C-17 C-17 C-17 4.43 4.43 4.43 4.43 4.43 3.12 3.12 3.12 3.12 3.12 4.43 3.12 5.25 5.25 5.25 5.25 60 CC-13 12 C-6 3 1.37 4.3 1000 2600 750 1950 2500 6800 750 750 1000 750 1000 1000 750 1000 1000 2600 120 1000 12 24 C-6 5.37 2000 1200 100 41459 100/300 6PK 200 100 120 120 120 30 CC-6 CC-6 6.68 4.43 1200 1500 1320 3300 4620 110 18980 110R30/FL/RS 46859 110R30/FL/RS/1 120 120 24 30 C-17 116 19008 116A21/TS 19009 116A21/TS 19010 116A21/TS 120 16241 120R40/FL-RVL 46875 120R40/FL/B 100 39503 100R30/CL 60 60 60 60 120 120 120 120 24 C-7A C-7A C-17 C-7A C-6 C-9 CC-6 CC-6 C-9 5.25 5.25 5.25 5.25 5.93 5.93 5.93 5.93 5.93 3.81 3.81 3.81 3.81 4.43 4.43 4.43 4.43 4.43 2B 2B 2B 2B 2A, 5E 2A, 5E 2A, 5E 5A 5A 2200 60 5E, 9D 1A, 2A, 2B, 9N 2B, 5A, 5E Bug-Lite Soft White Saf-T-Gard® Reveal® Soft White Reveal® Clear Inside Frost (Ratings @ 120 volts.) Survivor™-I.F., Long Life, Vibration Resistant, BB (Ratings @ 120 volts.) I.F. Silvered Bowl I.F. Rough Service Rough Service - Saf-T-Gard® I.F.-covRguard® Rough Service, Teflon® Coated Clear-Traffic Signal. Rated Watts: 98. BDTH I.F. Rough Service (Ratings @ 120 volts.) Inside Frost (Ratings @ 120 volts.) Diffuse Coating-Extended Service (Ratings @ 120 volts.) Inside Frost Inside Frost I.F. Rough Service Inside Frost Inside Frost I.F.-Train Inside Frost Clear-Commercial Oven I.F.-Vibration Service (Ratings @ 120 volts.) Clear Reflector. BDTH, BB PAR-Mine Flood Reflector-Clear, Swimming Pool, BB 100/200/300 WATTS PS25d 3C Mog 2B, 9C, 9J Soft White - 3-Way 2A, 5E, 9K 110 WATTS R30 Med 5.375 2000 1080 Reflector Flood. I.F. Rough Service, BB Reflector Flood. I.F. Rough Service 120 120 C-9 125 120 C-9 130 120 C-9 4.37 2.43 4.37 2.43 4.37 2.43 8000 8000 8000 1280 1280 1280 Clear-Traffic Signal, BDTH Clear-Traffic Signal, BDTH Clear-Traffic Signal, BDTH 120 120 6.56 6.563 2000 2000 116 WATTS A21 Med 120 WATTS BR40 Med 1-16 30 CC-6 30 CC-6 1450 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B Indoor Floodlight: Reveal Watt-Miser® - Reflector - Blue Incandescent Lamps Shape Base Order Watts Code Description Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information INCANDESCENT LAMPS (CONTINUED) 120 WATTS (CONTINUED) BR40 Med 120 46876 120R40/FL/PK 20333 120R/FL/MI/1 6PK 20334 120R/SP/MI/1 6PK 20824 120R/FLMI/TWIN 21000 120R40/PL-1 6PK 22715 120R/FL/COMM 6PK 47684 120R40/FLLLPQ1-6 46871 120R40/FL 46872 120R40/SP 46877 120R/40/FL/CVG 47725 120R40FL/STG PQ6 ER39 Med 120 41607 120ER39 PAR38 Med Sid Pr 120 80313 150PAR/3FL/120WM 80322 150PAR/3SP/120WM 120 120 120 120 120 120 120 130 130 130 130 120 120 120 30 30 30 3 30 30 30 30 30 30 30 24 12 12 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 6.563 6.56 6.56 6.56 6.56 6.56 6.56 6.563 6.563 6.56 6.56 7.37 4.3 4.3 2000 2000 2000 2000 2000 2000 2500 2000 2000 1700 1700 2000 2000 2000 1450 1600 1300 1600 1450 1550 1550 1425 1370 1370 1200 1200 1700 3600 9200 1600 1600 1600 2725 2725 30 18 B B Watt-Miser® - Reflector - Pink 2A, 2B, 5E, 9K Miser®-Reflector Flood 2A, 2B, 5E, 9K Reflector 2A, 2B, 5E, 9K Reflector Flood - Twin Pack 2A, 2B, 5E, 9K Reflector Plant Light, BB 2A, 2B, 5E, 9K Watt-Miser® Reflector Flood IF Indoor Floodlight - Long Life Watt-Miser® - Reflector - I.F. Reflector Reflector - covRguard® Teflon® Coated Reflector - Saf-T-Gard® Teflon® Coated 2A, 2B, 5E ER-Elliptical Reflector, Light I.F. 1A, 2A, 2B, 9N Watt-Miser®-Flood 1A, 2A, 2B, 9N Watt-Miser® Reflector 135 WATTS A21 Med 135 17973 150A21/135WM/TS 120 C-11V 4.68 3 7000 1750 17974 150A21/135WM/TS 120 C-11V 4.68 3 7000 1750 1000 1000 2600 2500 6800 2380 2340 1790 2060 1580 2780 1950 2650 2600 2850 1925 1470 2065 1580 2310 1765 2800 2140 2100 2100 1740 1740 1740 1740 12619 150A/135WM 135 12627 150A/135WM 120 135 13025 150A/135WMP/99 120 120 130 120 130 120 60 CC-8 60 CC-8 5.37 4.06 5.37 4.06 60 CC-8 5.37 4.06 150 10429 150A/W 12PK 16703 150A/RVL 22881 150A/RL/SW 6PK 22889 150A/GAR 12PK 41294 150A 24PK 150 15818 150A/S 133 150 17625 150A21/RS 133 150 25929 150A21/99/IF 133 150 33009 150A 133 150 19334 150P25/2SB 120 120 120 120 120 130 120 130 120 130 120 130 120 120 12 30 30 12 24 60 5.37 5.37 5.75 5.37 5.37 4.93 Watt-Miser®-Clear, Traffic Signal, Burn BDTH, BB, Krypton Watt-Miser®-Clear, Traffic Signal, Burn BDTH, BB, Krypton Watt-Miser®-Diffuse Coating Watt-Miser®-Diffuse Coating (Ratings @ 120 volts.) Watt-Miser®-Plus-Diffuse Coating, LongLife (Ratings @ 120 volts.) B B B B B 150 WATTS A21 P25 Med Med 19372 150P25/10 PAR38 Med Sid Pr 150 80321 150PAR/3SP/MINE 80315 150PAR/3FL/MINE 19489 150PAR/3SP/MINE 80317 150PAR/3FL/MINE Med Skirt 150 19464 150PAR/FL/A 19465 150PAR/FL/B 19467 150PAR/FL/G 19468 150PAR/FL/R 120 120 120 130 130 120 120 120 120 CC-8 CC-8 CC-8 CC-8 CC-8 C-9 60 C-17 5.25 3.81 60 CC-8 5.37 4.06 60 CC-8 5.37 4.06 60 C-7A 4.75 750 750 750 1125 750 2000 5500 1000 2600 2500 6800 750 1950 200 60 12 12 12 12 12 12 12 12 4.75 3 4.3 4.3 4.3 4.3 5.31 5.31 5.31 5.31 200 2000 2000 2000 2000 2000 2000 2000 2000 C-7A CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 4.06 4.06 4.31 4.16 4.06 3.37 2775 12000 3100 12000 3100 16 36 16 36 Soft White Reveal® Soft White-Reader Light™ I.F. - Garage Standard 2B Survivor™-I.F. Long Life. Vibration Resistant, BB (Ratings @ 120 volts.) 2A, 5E I.F.-Rough Service (Ratings @ 120 volts.) I.F.-Extended Service, BB (Ratings @ 120 volts.) Inside Frost (Ratings @ 120 volts.) Clear Reflector. Silvered Bowl. Hard glass button, BB Light I.F.-Spot. Hard glass button, BB 1A, 2A, 2B, 9N Mine Reflector 1A, 2A, 2B, 9N Mine-Flood 1A, 2A, 2B, 9N Mine Reflector 1A, 2A, 2B, 9N Mine-Flood 1A, 2A, 2B Flood. Dichro Amber 1A, 2A, 2B Flood. Dichro Blue 1A, 2A, 2B Flood. Dichro Green 1A, 2A, 2B Flood. Dichro Red For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B 1-17 Incandescent Lamps Shape Base Order Watts Code Description Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information INCANDESCENT LAMPS (CONTINUED) 150 WATTS (CONTINUED) PAR38 Med Skirt 150 26370 150PAR/FL/CVG 120 12 CC-6 5.31 2000 1700 26371 150PAR/SP/CVG 48037 150PAR/FL/STGPQ6 PAR46 3 Prong 150 35327 150PAR46/TS Scrw Term 150 19512 150PAR46/1 19517 150PAR46 Med Sid Pr 150 41968 150PAR46/3MFL 120 120 115 32 125 125 12 6 12 12 12 12 5.31 5.31 4 3.75 3.75 4 2000 2000 6000 800 1000 2000 1700 1700 1750 1950 1250 1500 PS25 Med 120 60 C-9 6.93 1000 2630 1A, 2A, 5B, 5C, 9N 2A, 9L, 9M 120 60 C-17 6.93 5.18 1000 2120 2A, 9L, 9M 120 130 120 130 120 130 120 130 120 130 120 230 130 60 C-9 60 C-9 6.93 5.18 6.93 5.18 60 C-17 6.93 5.18 60 C-9 6.93 5.18 60 C-9 6.93 5.18 24 C-9 6.93 5.18 60 C-9 24 CC-6 8.06 6 7.37 1000 750 1950 1000 2600 2500 6800 2500 6800 1000 2600 750 2000 2370 2520 1930 2160 1650 2200 1680 2200 1680 2270 1735 1950 1425 120 12 CC-6 5.31 4.31 5000 3100 120 120 120 130 120 130 120 130 120 130 120 120 12 12 12 60 5.37 5.37 5.37 5.37 3910 3980 3920 3850 2965 3850 2965 3250 2500 3250 2500 2270 2750 31000 150 14635 150PS25/CVG 14716 150/RS/CVG PS30 Med ER30 Med 19597 150/SBIF 150 19530 150/IF 133 150 19618 150/RS 133 150 19658 150/99/IF 133 150 19668 150/99CL 133 150 33465 150/VS 133 150 19756 150PS30 120 43231 120ER40 CC-6 CC-6 CC-6 CC-8 C-13 CC-13 1A, 2A, 2B, 9L, 9M 100000 2750 8000 2A, 5E 1700 2A, 2B, 5E covRguard® Flood, BB, Teflon® Coated covRguard® Spot, BB, Teflon® Coated Saf-T-Gard® Flood, BB, Teflon® Coated Traffic Signal - Burn Horiz. Mine Locomotive Headlight Mine Locomotive Headlight Medium Flood Inside Frost-covRguard®, BB, Teflon® Coated Inside Frost-covRguard® Rough Service, BB, Teflon® Coated I.F.-Silver Bowl Inside Frost (Ratings @ 120 volts.) Vibration Resistant I.F.-Rough Service (Ratings @ 120 volts.) I.F.-Extended Service (Ratings @ 120 volts.) Vibration Resistant Clear-Extended Service (Ratings @ 120 volts.) Vibration Resistant I.F.-Vibration Service (Ratings @ 120 volts.) Clear-Reflector. Silvered Neck ER-Elliptical Reflector, Light I.F. 175 WATTS PAR38 Med Skirt 175 13643 175PAR38/HEAT 1A, 2A, 2B, 3B Infrared-Clear 200 WATTS A21 Med 200 11585 200A/W-1 12PK 16069 200A/CL-1 12PK 25925 200A21/IF/12PK 200 25930 200A21/IF 130 177 200 25932 200A21/CL 177 200 25936 200A21/99/IF 177 200 25937 200A21/99/CL 130 177 PAR46 Med Sid Pr 200 20115 200PAR46/3NSP 4.06 4.06 4.06 4.06 60 CC-8 5.37 4.06 60 CC-8 5.37 4.06 60 CC-8 5.37 4.06 12 CC-13 4 750 750 750 750 1950 750 1950 2500 6800 2500 6800 2000 20138 200PAR46/3MFL 120 12 CC-13 4 2000 2270 2750 11500 20117 200PAR46/3NSP 130 12 CC-13 4 2000 2270 2750 31000 20140 200PAR46/3MFL 130 12 CC-13 4 2000 2270 2750 11500 30 120 12 CC-8 12 CC-13 4.5 5 350 2000 2270 230000 2750 15000 PAR56 Scrw Term 200 20122 200PAR Mog End Pr200 49889 200PAR56/MFL 1-18 CC-8 CC-8 CC-8 CC-8 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B Soft White Crystal Inside Frost Inside Frost (Ratings @ 120 volts.) Clear (Ratings @ 120 volts.) I.F.-Extended Service (Ratings @ 120 volts.) Clear-Extended Service (Ratings @ 120 volts.) Narrow Reflector Medium Flood Narrow Reflector Medium Flood Locomotive Headlight Medium Flood Incandescent Lamps Shape Base Order Watts Code Description Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information INCANDESCENT LAMPS (CONTINUED) 200 WATTS (CONTINUED) PS30 Med 200 14636 200PS30/CVG 120 60 C-9 8.06 6 1000 3480 2A, 9L, 9M 14637 200PS30/RS/CVG 120 60 C-9 8.06 6 1000 3330 2A, 9L, 9M 20316 200/SBIF 200 20172 200 177 200 20252 200/IF 177 200 20354 200/99IF 177 200 20403 200PS30/24 177 200 33468 200PS30/23 24PK 177 200 20192 200 120 130 120 130 120 130 120 130 120 130 120 250 60 C-9 60 C-9 8.06 6 8.06 6 60 C-9 8.06 6 60 C-9 8.06 6 60 C-9 8.06 6 24 C-9 8.06 6 60 C-9 8.06 6 1000 750 1950 750 1950 2500 6800 1000 2600 1000 2600 1000 3320 3540 2725 3540 2725 3000 2310 3240 2495 3240 2495 2980 A21 Med 240 15843 240A/RL/SW 6PK PAR56 Scrw Term 240 20575 240PAR56/VNSP 120 12 30 CC-8 12 C-6 5.75 4.31 4.5 750 2000 4300 20576 240PAR56/MFL 12 12 C-6 4.5 2000 2800 46000 20577 240PAR56/WFL 12 12 C-6 4.5 2000 2800 13000 120 30 C-9 6.56 5000 37771 250R40/10 6PK 120 30 C-9 6.56 5000 46881 250R40/1/CVG 120 30 C-9 6.56 5000 120 24 C-9 7.43 5000 PAR56 Scrw Term 300 23427 300PAR56/WFL PAR56 Mog End Pr300 20803 300PAR56/NSP 12 120 12 C-6 12 CC-13 4.5 5 1000 2000 6000 3840 2750 68000 20836 300PAR56/MFL 120 12 CC-13 5 2000 3840 2750 24000 20849 300PAR56/WFL 120 12 CC-13 5 2000 3840 2750 11000 20838 300PAR56/MFL 130 12 CC-13 5 2000 3840 2750 24000 20851 300PAR56/WFL 130 12 CC-13 5 2000 3840 2750 11000 120 120 130 120 130 120 60 CC-8 30 CC-8 60 CC-8 6.93 5.18 6.93 5.18 6.93 5.18 60 CC-8 6.93 5.18 750 750 750 1950 750 1950 6200 6200 6120 4170 6120 4170 2A, 5E 2A, 5E 2A, 5E Inside Frost-covRguard®, BB, Teflon® Coated Inside Frost-covRguard® Rough Service, BB, Teflon® Coated I.F.-Silvered Bowl Clear (Ratings @ 120 volts.) Inside Frost (Ratings @ 120 volts.) I.F.-Extended Service, BB (Ratings @ 120 volts.) Clear-Rough Service (Ratings @ 120 volts.) I.F.-Rough Service (Ratings @ 120 volts.) Clear 240 WATTS 2800 140000 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N Soft White-Reader Light™ Very Narrow Reflector Medium Flood Wide Flood 250 WATTS R40 Med 250 37770 250R40/1 6PK Med Skirt 250 20724 250R40/4 2200 2A, 2B, 3B, 5E, 6A 2A, 2B, 3B, 5E, 6A 2150 2A, 2B, 3B, 5E, 6A Reflector-Warm Up Infrared Heat Lamp - Clear Face Reflector-Chill Chaser Infrared Heat Lamp. Red, HRG Clear-covRguard® Teflon® Coated. Food Warming, Reflector-Infrared Reflector Infrared Industrial-Light I.F., BB 300 WATTS PS25 Med 300 20861 300M 25919 300M/IF 6PK 300 20863 300M 266 300 20917 300M/IF 266 2B, 9F, 9N 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B PAR-Wide Flood. Swimming Narrow Reflector Medium Flood Wide Flood Medium Flood Wide Flood Clear Inside Frost Clear (Ratings @ 120 volts.) Inside Frost (Ratings @ 120 volts.) 1-19 Incandescent Lamps Shape Base Order Watts Code Description Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information INCANDESCENT LAMPS (CONTINUED) 300 WATTS (CONTINUED) PS30 Med 300 20887 300M/99 266 300 20894 300M/99IF 266 PS35 Mog 300 21025 300 21079 300/IF 21139 300/SBIF 21167 300/99 21177 300/99IF R40 Med 300 21197 300R/SP 21213 300R/FL 21229 300R/FL/1 300 21215 300R/FL 266 Mog 300 21254 300R/3FL 21256 300R/3FL 21263 300R/3FL T20 Med BiPost300 21280 300T20/1 130 120 130 120 130 130 130 130 130 120 120 120 130 120 120 130 250 120 60 C-9 8.06 6 60 C-9 8.06 6 24 24 24 24 24 24 24 24 24 C-9 C-9 C-9 C-9 C-9 CC-2V CC-2V CC-2V CC-2V 9.37 9.37 9.37 9.37 9.37 6.56 6.56 6.75 6.56 24 24 24 12 CC-2V CC-2V C-7A C-13 7.25 7.25 7.25 6.5 4 7 7 7 7 7 2500 6800 2500 6800 1000 1000 1000 2500 2500 2000 2000 2000 2000 5400 2000 2000 2000 1000 5110 3935 5110 3935 5820 5820 5410 5190 5190 3700 3700 3700 3465 2670 3750 3750 3300 5500 6200 9000 2500 1900 2500 2A, 2B, 5B, 9E 2A, 2B, 5B, 9E 2A, 2B, 5B, 9E 2A, 2B, 5B, 9E 2A, 2B, 5B, 9E 2A, 2B, 5B, 9E 2A, 2B, 5B, 9E 8A, 9G Clear-Extended Service (Ratings @ 120 volts.) I.F.-Extended Service (Ratings @ 120 volts.) Clear Inside Frost I.F.-Silver Bowl. Burn base up Clear-Extended Service I.F.-Extended Service Reflector -Light I.F. HORIZ Reflector Flood-I.F. HORIZ Reflector Flood-I.F. BB, HRG Reflector Flood-I.F. HORIZ (Ratings @ 120 volts.) Reflector Flood-I.F. BB Reflector Flood-I.F. BB Reflector Flood-I.F. BB Inside Frost, HRG 350 WATTS PAR56 Scrw Term 350 19866 350PAR56/SP 75 12 CC-8 4.5 500 115 24 C-9 7.37 5000 115 24 C-9 7.5 5000 120 120 120 60 C-5 24 CC-2V 5.12 3 6.75 800 2000 6800 5000 PAR64 MogEndPr 500 39411 500PAR64/MFL 230 12 CC-13 6 2000 5500 2700 39414 500PAR64/WFL 230 12 CC-13 6 2000 5500 2700 ExMogEndPr500 39406 500PAR64/NSP 120 12 CC-13 6 2000 6500 2800 110000 39409 500PAR64/MFL 120 12 CC-13 6 2000 6500 2800 37000 39412 500PAR64/WFL 120 12 CC-13 6 2000 6500 2800 13000 120 130 130 130 130 120 24 24 24 24 24 24 9.37 9.37 9.37 9.75 9.75 9.75 1A, 2A, 5B, 5C, 9N Ditch Light-Locomotive 2A, 2B, 3B, 5E, 6A 2A, 2B, 3B, 5E, 6A Reflector Infrared Industrial-Light I.F., BB Reflector Infrared Industrial-Clear Face, HRG, BB 375 WATTS R40 Med Skirt 375 21331 375R40 21334 375R40/1 400 WATTS G30 R40 Med Med 400 21363 400G/FL 400 17542 400R40/FL 2A, 2B, 2D, 5B Clear Flood, BDTH, BB 5B, 5C, 9B Reflector Flood. Swimming Pool, BB, HRG 500 WATTS PS35 Mog PS40 Mog 1-20 500 21530 500 21532 500 21581 500/IF 21651 500/99IF 500 21643 500/99 21687 500PS40 CC-8 CC-8 CC-8 C-9 C-9 C-9 7 7 7 7 7 7 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N 1000 10850 1000 10850 1000 10850 2000 9070 2000 9070 1000 9900 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B Medium Flood Wide Flood Narrow Reflector Medium Flood Wide Flood Clear, BB Clear, BB Inside Frost, BB I.F.-Extended Service, BB Clear-Extended Service, BB Clear, BB Incandescent Lamps Shape Base Order Watts Code Description Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information INCANDESCENT LAMPS (CONTINUED) 500 WATTS (CONTINUED) R40 R52 T20 Mog 500 21734 500R/3FL 21736 500R/3FL Mog 500 21761 500R52 Med BiPost 500 21872 500T20/50 120 130 130 130 24 24 12 12 130 130 130 130 250 277 120 CC-2V CC-2V C-7A C-13 7.25 7.25 11.75 6.5 4 2000 2000 2000 1000 6500 6500 7600 9800 2A, 2B, 5B, 9E Reflector Flood-I.F. BB, HRG 2A, 2B, 5B, 9E Reflector Flood-I.F. BB, HRG Reflector High Bay-Light I.F. BB 8A, 9G I.F. HRG 12 CC-8 24 C-13 13 9.5 9.18 5.5 1000 17040 1000 14800 5D, 5E 8A, 9G Clear, BB Inside Frost, HRG 12 12 12 12 24 CC-8 C-7A C-7A C-7A C-13 13 13 13 13 9.18 1000 2500 2000 2000 1000 5D, 5E 5D, 5E 5D, 5E 5D, 5E 8A, 9G Clear, BB Clear-Extended Service, BB Clear, BB Clear, BB Inside Frost, HRG 2C, 5A, 5E Reflector Flood-I.F. Swimming pool. BDTH, HORIZ, HRG, BB Clear-Sound Reproduction Optical Comparator. Source WxH: 1.8 x 4.6mm. ANSI: BXE, BB 750 WATTS PS52 Mog 750 22000 750 T24 Med BiPost 750 22117 750T24 1000 WATTS PS52 Mog T24 1000 22260 1000 22301 1000/99 22280 1000 22284 1000 Med BiPost1000 22479 1M/T24 9.5 9.5 9.5 9.5 5.5 23740 19800 17700 17700 21200 MISC. INCANDESCENT LAMP TYPES R40 Med 23423 21A/R40/FL 12 24 C-2V 6.68 T8 SC Bay 23326 7.5A/T8/92SC 10 24 C-8Z 3.12 1.75 PAR38 Med Skirt 65 14505 75PAR/SP/65/WM/EX 130 14506 75PAR/FL/65WM/EX 130 12 CC-6 12 CC-6 120 PAR38 Med Skirt 85 14509 100PAR/FL/85WM/EX 120 1000 100 1620 5.31 5.31 2000 2000 675 675 2675 2675 5900 1750 14 30 1A, 2A, 2B 1A, 2A, 2B Watt-Miser®, Reflector Watt-Miser®, Flood 12 CC-6 5.31 2000 765 2700 1750 33 1A, 2A, 2B Flood 6 CC-6 5.31 2000 930 2700 2000 37 B 1A, 2A, 2B Miser® Flood 12 CC-6 12 CC-6 12 CC-6 5.31 5.31 5.31 2000 2000 2000 1370 1370 1370 2725 2725 2725 3600 9200 3600 30 18 30 2A, 2B B 1A, 1A, 2A, 2B B B 1A, 2A, 2B Watt-Miser®, Flood Watt-Miser®, Reflector Watt-Miser®, Flood 12 CC-6 12 CC-6 5.31 5.31 2000 2000 1740 1740 2775 3100 2775 12000 36 16 1A, 2A, 2B 1A, 2A, 2B Flood Reflector 1A, 2A, 2B Clear Reflector 1A, 2A, 2B 1A, 2A, 2B Clear Flood Clear Flood EXPORT-ONLY 65 WATTS 75 WATTS PAR38 Med Skirt 75 14510 75PAR/FL/EX 85 WATTS 120 WATTS PAR38 Med Skirt 120 14501 150PAR/FL/120WM/EX 120 14502 150PAR/SP/120WM/EX 120 14503 150PAR/FL/120WM/EX 130 150 WATTS PAR38 Med Skirt 150 14531 150PAR/FL/EX 14535 150PAR/SP/EX 120 120 E27 BASE-EXPORT 80 WATTS PAR38 Skirted (E27) 80 18180 80PAR/SP/27 220/0 12 220/0 240/0 12 CC-6 12 CC-6 100 WATTS PAR38 Skirted (E27)10038854 100PAR/FL/27 42711 100PAR/FL/27 5.5 5.5 2000 2000 800 800 2600 2600 1500 1500 35 35 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B 1-21 Incandescent Lamps Shape Base Order Watts Code Description Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information E27 BASE-EXPORT (CONTINUED) 120 WATTS PAR38 Skirted 120 18172 120PAR/FL/27 18173 120PAR/FL/27 PAR56 Scrw Term 120 19023 120PAR56VNSP 220/0 240/0 12 12 CC-6 12 CC-6 12 C-6 5.5 5.5 4.5 2000 2000 2000 1150 1050 1050 2675 2300 2675 2300 2750 60000 19024 120PAR56/MFL 35 35 1A, 2A, 2B 1A, 2A, 2B 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N Clear Flood Clear Flood Very Narrow Reflector 12 12 C-6 4.5 2000 1050 2750 19000 19025 120PAR56WFL 12 12 C-6 4.5 2000 1050 2750 5625 150 40033 150PAR/FL/27 40035 150PAR/FL/27 220/0 240/0 12 CC-6 12 CC-6 5.5 5.5 2000 2000 1350 1350 2650 2650 2450 2450 PAR56 GX16DEXT 300 20852 300PAR56/MFL 230 12 CC-13 5 2000 3450 20853 300PAR56/NSP 230 12 CC-13 5 2000 3450 20854 300PAR56/WFL 230 12 CC-13 5 2000 3450 18676 300PAR56/NSP 240/0 12 CC-13 5 2000 3450 18677 300PAR56/MFL 240/0 12 CC-13 5 2000 3450 18678 300PAR56/WFL 240/0 12 CC-13 5 2000 3450 60 C-9 60 C-9 4.75 3 4.75 3 8000 8000 1950 1950 60 C-2V 3.93 1.5 1000 400 Clear 60 CC-2V 3.93 1.5 1000 400 Clear 12 C-8 60 C-2V 4.5 3.93 1.5 1000 1000 700 675 Stippled cover Clear 12 C-6 4 3000 780 200 23298 6.6A/T14P 24 C-13 5.75 2.18 204 23300 6.6A/T14/2P 24 C-13 5.75 2.18 Medium Flood Wide Flood 150 WATTS PAR38 Skirted 35 35 1A, 2A, 2B 1A, 2A, 2B Clear Flood Clear Flood 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N 1A, 2A, 5B, 5C, 9N Medium Flood EXPORT PAR 300 WATTS Narrow Reflector Wide Flood Narrow Reflector Medium Flood Wide Flood LUMEN RATED TRAFFIC SIGNAL 165 WATTS P25 Med 165 20094 1950L/P25/TS 20097 1950L/P25/TS 120 130 Clear-Traffic Signal (BDTH), BB Clear-Traffic Signal (BDTH), BB AIRPORT 30 WATTS T10 Med Pf 30 23294 6.6A/T10/1P 40 WATTS T10 Med Pf 40 15921 40T10P 120 45 WATTS PAR56 Scrw Term 45 23310 6.6A/PAR56/5 T10 Med Pf 45 23295 6.6A/T10P 120 WATTS PAR64 Scrw Term 120 39395 120PAR 6 180000 Transmissometer. Filament Shielded. Very Narrow Reflector 200 WATTS T14 Med Pf 4900 Clear 4220 Clear 204 WATTS T14 1-22 Med Pf 500 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B Incandescent Lamps Shape Base Order Watts Code Description Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information AIRPORT (CONTINUED) 620 WATTS PS40 Mog Pf 620 21950 620PS40P 21952 620PS40P 120 130 24 C-9 24 C-9 10.06 5.68 10.06 5.68 3000 11200 3000 11200 Clear Clear 120 12 C-13 9.5 4 500 22000 Clear-Beacon, HRG 115 12 CC-8 9.5 4 750 29600 Clear-Beacon, HRG 1000 WATTS T20 Mog BiPost1000 22429 1M/T20BP 1200 WATTS T20 Mog BiPost1200 22524 1200T20 MULTIPLE STREET LIGHTING A23 Med PS25 Med PS35 Mog PS40 Mog 105 42392 105A23/12 189 19939 189PS25/64 205 42663 205PS25/12 295 20772 295PS35/58 327 21307 327PS35 405 21408 405PS40/54 125 120 C-9 130 60 C-9 125 60 C-9 125 24 C-9 125 24 C-9 120 24 C-9 5.93 6.93 6.93 9.37 9.37 9.75 4.43 12000 5.25 3000 5.25 12000 7 3000 7 6000 7 3000 Clear, BB Clear, BB Clear, BB Clear, BB Clear, BB Clear, BB 120 120 30 30 4.125 4.125 2000 2000 Flicker Flame Flicker Flame 15 81559 15BC/CF/CD2-TRAY 48400 15BC CD2 6PK 15 46678 15 BFC PQ2/5 15 41524 15CAC/L 48403 15CAC/F CD2 6PK 15 12578 15GC/L 120 30 C-7A 120 30 C-7A 120 25 C-7A 120 120 C-7A 120 30 C-7A 120 60 C-7A 3.19 3.87 3.87 4.12 4.12 3 1500 1500 1500 4000 1500 4000 Blunt Tip, Ceiling Fan, Vibration Resistant Clear-Blunt Tip Faceted-Blunt Tip Clear-Bent Tip, LL Frost-Bent Tip Clear-Globe, LL 3.19 1500 3.75 3.75 3.75 4.62 4.12 4.12 4.12 4.12 4.12 4.12 4.37 4.37 4.37 4.37 3 3 3 1500 1500 1500 1500 1500 1500 1500 4000 4000 1500 1500 1500 1500 1500 1500 1500 1500 6850 DECORATIVE 3 WATTS CA10 Cand CA10 Med 3 81167 3CAC/FF/CD1-6PK 3 81168 3CAM/FF/CD1-6PK 15 WATTS B8 Cand B10 CA8 Cand Cand G16.5 Cand 25 WATTS B8 Cand 25 81560 25BC/CF/CD2-TRAY 120 B10 Cand 25 15787 25BC 25PK 46679 25BFC PQ2/5 48700 25BC/RVL CD2 25 22756 25BM CD2 25 15777 25CAC 25PK 16045 25CAC CARD4 16046 25CAC/F CARD4 16365 25CAC/L-CD4 40045 25CAC/L 47933 25CAC CARD 2 25 18890 25FM CD2 6PK 18891 25FM/A CD2 6PK 18894 25FM/AU CD2 6PK 18895 25FM/W CD2 6PK 25 11303 25GC 12PK 15790 25GC 25PK 17722 25GC CD2 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 B13 Med CA10 Cand F15 Med G16.5 Cand 30 C-7A 200 25 30 60 200 30 30 120 120 30 30 30 30 30 120 100 60 C-7A CC-2V CC-2V C-9 CC-2V CC-2V CC-2V CC-2V CC-2V CC-2V C-6 C-6 C-6 C-6 CC-2V CC-2V CC-2V 5E, 9D For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B Blunt Tip, Ceiling Fan, Vibration Resistant, BDTH Clear-Blunt Tip Faceted-Blunt Tip Reveal® Clear-Blunt Tip Clear-Blunt Tip Clear-Bent Tip Clear-Bent Tip Frost-Bent Tip Clear-Bent Tip, LL Clear-Bent Tip, LL Clear-Bent Tip Clear-Flame Amber-Flame Auradescent-Flame White-Flame Clear-Globe Clear-Globe Clear-Globe 1-23 Incandescent Lamps Shape Base Order Watts Code Description Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information DECORATIVE (CONTINUED) 25 WATTS (CONTINUED) G16.5 Cand G16.5 Med G25 Med 23510 25GC/AU-CD2 27301 25GC CD4 27302 25GC/W CD4 39679 25GC/W 12PK 43158 25GC-L 48703 25GC/RVL CD2 25 31106 25GM/CL-PQ2/6 31107 25GM/W-PQ2/6 31108 25GM/AU-PQ2/6 25 12982 25G25/W 6PK 12983 25G25 6PK 20408 25G25/L/24 20410 25G25/W/L/24 25545 25G25 CPK 25546 25G25/W CPK 120 60 CC-2V 120 30 CC-2V 120 30 CC-2V 120 120 CC-2V 120 60 CC-2V 120 30 CC-2V 120 30 CC-2V 120 30 CC-2V 120 30 CC-2V 120 6 C-9 120 6 C-9 120 24 C-9 120 24 C-9 120 24 C-9 120 24 C-9 3 3 3 3 3 3 3 3 3 4.5 4.5 4.5 4.5 4.5 4.5 1500 1500 1500 1500 4000 1500 1500 1500 1500 1500 1500 3000 3000 1500 1500 Auradescent - Globe Clear-Globe White-Globe White-Globe Clear-Globe, LL Reveal® Clear-Globe Clear-Globe, Medium Base White-Globe, Medium Base Auradescent-Globe, Medium Base White-Globe Clear-Globe Clear-Globe, LL White-Globe, LL Clear-Globe White-Globe 3.19 1500 5E, 9D 3.75 3.75 3.75 3.75 3.75 3.75 4.62 4.62 4.62 4.625 4.56 4.56 4.56 4.12 4.12 4.12 4.12 4.12 4.12 4.37 4.37 4.37 3 3 3 3 3 3 3 3 3 3 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 3000 1500 1500 1500 1500 3000 3000 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 5E, 9D 5E, 9D 5E, 9D 5E, 9D 5E, 9D 5E, 9D 5E, 9D 5E, 9D 5E, 9D 5E, 9D 40 WATTS B8 Cand 40 81561 40BC/CF/CD2-Tray 120 B10 Cand B13 Med CA9 Med 40 15788 40BC 25PK 19110 40BC CD2 6PK 19981 40BC CARD4 27292 40BFC CD2 6PK 48701 40BC/RVL CD2 48702 40BC/RVL CD4 40 12993 40BM CD2 27310 40BM/CD4 40891 40BFM PQ2/6 48699 40BM/RVL CD2 40 48391 40CAM/F CD2 6PK 16049 40CAM CARD4 22813 40CAM/LL/BB CD2 40 15778 40CAC 25PK 16047 40CAC CARD4 16048 40CAC/F CARD4 19107 40CAC CD2 6PK 22812 40CAC/LL/BB CD2 40050 40CAC/L 40 18896 40FM CD2 6PK 18897 40FM/AU CD2 6PK 18899 40FM/W CD2 6PK 40 14958 40GC 12PK 17730 40GC CD/2 23511 40GC/AU CD/2 27303 40GC CD4 27304 40GC/W CD4 48704 40GC/RVL CD2 48705 40GC/W/RVL CD2 40 31109 40GM/CL-PQ2/6 31110 40GM/W-PQ2/6 31113 40GM/AU-PQ2/6 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 CA10 Cand F15 Med G16.5 Cand G16.5 Med 1-24 30 C-7A 200 30 30 30 30 30 60 6 30 30 30 30 30 200 30 30 30 30 120 30 30 30 120 60 60 30 30 30 30 30 30 30 CC-2V CC-2V CC-2V CC-2V CC-2V CC-2V C-9 C-9 C-9 C-9 CC-2V CC-2V CC-2V CC-2V CC-2V CC-2V CC-2V CC-2V CC-2V C-6 C-6 C-6 CC-2V CC-2V CC-2V CC-2V CC-2V CC-2V CC-2V CC-2V CC-2V CC-2V For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B Clear-Blunt Tip, Ceiling Fan, Vibration Resistant, BDTH Clear-Blunt Tip Clear-Blunt Tip Clear-Blunt Tip Faceted-Blunt Tip Reveal® Clear-Blunt Tip Reveal® Clear-Blunt Tip Clear-Blunt Tip Clear-Blunt Tip Faceted-Blunt Tip Reveal® Clear-Blunt Tip Frost-Bent Tip Clear-Bent Tip Clear-Bent Tip, LL, Post Light Clear-Bent Tip Clear-Bent Tip Frost-Bent Tip Clear-Bent Tip Clear-Bent Tip, LL, Post Light Clear-Bent Tip, LL Clear-Flame Auradescent-Flame White-Flame Clear-Globe, BDTH Clear-Globe, BDTH Auradescent - Globe, BDTH Clear-Globe, BDTH White-Globe, BDTH Reveal® Clear-Globe, BDTH Reveal® White-Globe, BDTH Clear-Globe, Medium Base, BDTH White-Globe, Medium Base, BDTH Auradescent-Globe, Medium Base, BDTH Incandescent Lamps Shape Base Order Watts Code Description Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information DECORATIVE (CONTINUED) 40 WATTS (CONTINUED) G25 Med G30 G40 Med Med T10 Med M14 Med 40 12979 40G25/W 6PK 12980 40G25 6PK 20419 40G25/L/24 20420 40G25/W/L/24 25547 40G25/W CPK 25548 40G25 CPK 46675 40DG25/F PQ1/6 48694 40G25C/RVL PQ1/6 48695 40G25W/RVL PQ1/6 40 27499 40G30/W 40 36191 40G40/W 6PK 37914 40G40/CL 40 48707 40T10/RVL CD1 48709 40T10/F/RVL CD1 40 46680 40M14/F/CF PQ2/6 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 6 6 24 24 24 24 30 6 6 24 6 24 25 25 30 C-9 C-9 C-9 C-9 C-9 C-9 C-9 C-9 C-9 CC-6 CC-6 CC-6 C-8 C-8 C-9 60 27298 60BC/CD4 48714 60BC/RVL CD2 48715 60BC/RVL CD4 60 22757 60BM CD/2 27497 60BM/CD4 48713 60BM/RVL CD2 60 21009 60CAM CARD4 48401 60CAM CD2 6PK 60 15781 60CAC 25PK 16050 60CAC CARD4 16051 60CAC/F CARD4 19153 60CAC CD/2 6PK 48404 60CAC/F CD2 6PK 60 23091 60GC CD/2 40388 60GC CD4 40389 60GC/W CD4 60 31114 60GM/CL-PQ2/6 31115 60GM/W-PQ2/6 60 14846 60G25 6PK 14848 60G25/W 6PK 20427 60G25/24 20428 60G25/W/24 60 14850 60G30/W 6PK 60 14187 60G40 6PK 16741 60G40/W CPK 49780 60G40/W 6PK 60 48710 60T10/RVL CD1 120 30 CC-2V 120 30 CC-2V 120 30 CC-2V 120 60 120 6 C-9 120 30 C-9 120 30 CC-2V 120 30 CC-2V 120 200 CC-2V 120 30 CC-2V 120 30 CC-2V 120 30 CC-2V 120 30 CC-2V 120 60 CC-2V 120 30 CC-2V 120 30 CC-2V 120 30 CC-2V 120 30 CC-2V 120 6 C-9 120 6 C-9 120 24 C-9 120 24 C-9 120 24 CC-9 120 6 CC-6 120 24 CC-6 120 6 CC-6 120 25 C-8 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 5 6.93 6.93 5.625 5.625 3.25 1500 1500 3000 3000 1500 1500 1500 1500 1500 2500 2500 2500 1000 1000 1500 White-Globe Clear-Globe Clear-Globe, LL White-Globe, LL White-Globe Clear-Globe Designer-Frosted Swirl Top Reveal® Reveal® White-Globe White-Globe Clear-Globe Reveal® Clear-Showcase Reveal® Frost-Showcase Frost-Swirl Top 3.75 3.75 3.75 1500 1500 1500 4.62 4.625 4.56 4.56 4.12 4.12 4.12 4.12 4.12 3 3 3 3 3 4.5 4.5 4.5 4.5 5 6.93 6.93 6.93 5.625 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 2500 2500 2500 2500 1000 Clear-Blunt Tip Reveal® Clear-Blunt Tip Reveal® Clear-Blunt Tip Clear-Blunt Tip Clear-Blunt Tip Reveal® Clear-Blunt Tip Clear-Bent Tip, BDTH Clear-Bent Tip Clear-Bent Tip Clear-Bent Tip Frost-Bent Tip Clear-Bent Tip Frost-Bent Tip Clear-Globe, BDTH Clear-Globe, BDTH White-Globe, BDTH Clear-Globe, Medium Base, BDTH White-Globe, Medium Base, BDTH Clear-Globe White-Globe Clear-Globe White-Globe White-Globe. Retail Pack Clear-Globe White-Globe White-Globe Reveal® Clear-Showcase 5 4000 6.93 2500 60 WATTS B10 Cand B13 Med CA9 Med CA10 Cand G16.5 Cand G16.5 Med G25 Med G30 G40 Med Med T10 Med 2C, 9I 5E, 9D 5E, 9D 5E, 9D 5E, 9D 5E, 9D 75 WATTS E17 Med 75 28917 75E17/TF-PQ1/4 120 20 CC-6 G40 Med 75 36193 75G40/W 6PK 120 6 CC-6 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B Post Light , Teflon® Coated, Saf-T-Gard® BB White-Globe 1-25 Incandescent Lamps Shape Base Order Watts Code Description Case Filament Volts Qty. Design MOL LCL Rated Life Lumens Hours Initial Color Temp. K CBCP Beam Spread Footnotes Additional Information DECORATIVE (CONTINUED) 100 WATTS F20 Med 100 44540 100F20/TF-PQ1/6 120 30 CC-9 5 3000 G40 Med 100 16742 100G40/W CPK 49781 100G40/W 6PK 120 120 24 CC-6 6 CC-6 6.93 6.93 2500 2500 Post Light , Teflon® Coated, Saf-T-Gard® BB White-Globe White-Globe 150 16585 150G40/W 120 24 CC-6 6.93 2500 White-Globe 120 4 CC-6 150 WATTS G40 Med PORTABLE LIGHTING PRODUCTS R30 Med 75 44848 PLK-1 2A, 5E, 9K Plant Light Kit includes one 75R30/PL Plant Light lamp, UL listed holder and information booklet. GENERAL INFORMATION 1 6 WARNING Risk of electric shock a. Turn off power before inspection, installation or removal WARNING Risk of burn a. Do not touch operating lamp 2 7 WARNING Risk of fire a. Keep combustible materials away from lamp b. Use in fixture rated for this product c. Use in fixture rated for this product – see instructions d. Operate base down to horizontal only e. Keep away from bed coverings, drapes and other combustible materials f. Do not use in enclosed fixture or with lamp shade g. Use in a high intensity fixture rated for this product h. Do not use as a night light i. Burning position base down only CAUTION Risk of burn a. Allow lamp to cool before handling b. Allow lamp/fixture to cool before handling c. Do not touch operating lamp 8 CAUTION Lamp may shatter and cause injury if broken a. Do not use excessive force when installing lamp 9 OPERATING INSTRUCTIONS a. Burning position – base up b. Burning position – horizontal c. Burn base down only d. Burn base down to horizontal e. For best performance burn lamp within 45 degrees of vertical base up f. For best performance burn within 45 degree of base down to horizontal g. For best performance operate base up within 30° of vertical h. For best performance burn base down i. Do not burn in base up position j. To produce all three levels of light, this lamp should be tightened firmly, but not forcibly, in the socket to assure that all contacts are connected k. Should not be used in equipment where the base lamp will exceed 550°F (260°C) l. Will operate in any burning position, but fixed-socket usage other than base up, or continuous burning in any position in ambient temperatures above 150°F (66°C), may result in some loss of protective coating m. Reflectors and accessories may raise bulb temperature n. For use with heat-resistant connector supported by bulb rim or metal shell of base o. For best performance replace lamp if it blisters or darkens 3 WARNING Lamp emits IR radiation which may cause eye injury a. Use in fixture approved for this product b. Do not use on infant, disabled, sleeping, or unconscious person/animal unable to avoid potential injury 4 WARNING Pressurized lamp-unexpected rupture may cause injury, fire, or property damage a. Use eye protection when handling lamp b. Avoid direct water/liquid contact c. Use in enclosed fixture rated for this product d. Operate lamp only in specified position 5 WARNING Unexpected lamp rupture may cause injury, fire, or property damage a. Do not exceed rated voltage b. Avoid direct water/liquid contact c. Use in enclosed fixture rated for this product d. Do not use lamp if outer glass is scratched or broken e. Avoid direct water, liquid, or metal contact 1-26 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B Incandescent Lamps INCANDESCENT LAMPS CROSS REFERENCE GE Description Osram/Sylvania Description Philips Description GE Description Osram/Sylvania Description Philips Description ORDER THIS IF YOU CURRENTLY USE GE LAMP THESE LAMPS INCANDESCENT LAMPS ORDER THIS IF YOU CURRENTLY USE GE LAMP THESE LAMPS INCANDESCENT LAMPS (CONTINUED) 3S6/5 24PK 130V 4C7 CARD 2 4C7/W CD2 10S11N 10S11N/F 15S14/GR/CL 130V 15CAC/F-CD/2 25BC (120) 25CAC (120) 25CAC/F (120) 25CAC/L (120) 25FM CD2 (120) 25GC (120) 40A15 40A 130V 40A/CL 130V 40R14/N/CD 40S11N/1/F 40T61/2/2 40T8 40T10 40A/34/WMP/99 (120, 130) 40BC (120) 40BC/W (120) 40CAC (120) 40CAC/F (120) 40CAM (120) 40CAM/F (120) 40FM (120) 40S11N/1/F 50A21 (12, 30, 34) 50A/RS 24 PK 50A/RS/CVG 50/150 60A 48 PK 60A/CVG (120) 60BC (120) 60CAC (120) 60CAC/F (120) 60CAM (120) 60A/PL 60T10F/CD (120) 65R30/FL/LL 65R30/SP/LL 75A 48PK 75 A/S (120, 130) 65R30/PL-1 6PK 75A/CL 24PK 75A/RS 12PK 75ER30 65R30/FL/B 65R30/FL/G 65R30/FL/Y 65R30/FL/PK 100A 130V 100A/S 130V 100A/CL 24 PK 100A/90WM 100A/RS 100A23/VS 24PK 100A23 100A21/99 (120, 130) 100A21/SBIF (120) 100A/RS (120,130) 100A23/VS (120,130) (120,130) 100A/RS/CVG (120) 150A21/99/IF (120,130) — — 60A/GRO 60T10/CF (120) — — 75A/RP 120V 75A/99/XL (120,130) 65BR30/GRO/RP 120V 75A/CL/RP 120V 75A/RS/RP 120V 75ER30 120V 65BR30/BV/RP 120V 65BR30/G/RP 120V 65BR30/Y/RP 120V 65BR30/PK/RP 120V 100A/CVP 130V 100A/RS/XL 100A/CL-120V 100/90/W/ES/4PK 100A/RS/RP 130V — — 100A/99/XL (120,130) — 100A/RS 100A/VS (120,125,130) 60BA9C/F (120) 60BA91/2 (120) 60A/AGRO (120) 60T10/64IF (120) 65BR30/FL/LL551 65BR30/SP/LL20/1 75A-120V 75A/99 (120,130) — 75A/CL-130V 75A/RS/VS 120V 75ER30 120V 75BR30/B 120V 75BR30/G 120V 75BR30/Y 120V 75BR30/PK 120V 100A 130V 100A/RS/VS 125-130V 100A/CL 120V 100-90/EW/48PK 100A/RS/VS 125-130V — 100A (12) 100A/99 (120,130) 100A/SBIF (120) 100A/RS/VS (120,130) 100A/RS/VS(2) 100A21/RS/SL — 200A21/99CL (120-130) 200PS30/CVG (120) 200PS30/RS/CVG (120) 250R40/10 300M 120V 300M (120, 130V) 300M/IF 130V 300M/99 (120, 130V) — 200PS30/SL 200PS30/23/SL 250R40/10 300M/CL 120V 300M/CL 130V 300M/IF 130V 300M/CL/99/XL 130V 100A/RS/TF (120) 150A21/RS/VS/BR 120130V LAMP 200A/99CL (130) 200/TF (120) 200PS30/RS/TF (120) 250R40/HR (120) 300M 120V 300-120V CLR PS30 300M/PS30IF 130V 300M/99 130V 3S6/5 130V 4C7/BL/2PK 4C7/W/2PK 120V 10S11N/CL 10S11/IF 15S14/CL 130V — 25B10C/T/BL/2PK 25B10C/BL/2PK 25B10C/W/BL/2PK 25B10C/DL/BL 25F (120-125) — 40A15 120V 40A-130V 40R/CL-130V 40R14N/RP 40S11N/CF 120V 40T6.5/CL/BL/6PK 40T8 120-130V 40T10-120V 40A/99/XL (120,130) 40C91/2C/BL (120-125) 40C91/2C/W/BL (120-125) 40B10C/BL (120-125) — 40C11/BL (120) — 40F (120-125) 40S11N/CF 50A21 50A/RS-120V 50A/RS/SL 50/150A/W 60A/CVP-130V 60A/SL (120) 60B10C/ST/BL (120-125) 60B10C/BL (120-125) 3S6/5 120-130V BC-4C7 BC4C7/W 10S11N 10S11N/IF — — 25B101/2 (120) 25BA9C (120) 25BA9C/F (120) 25BA9C/4M 25F15 (120) 25G161/2C (120) 40A15-SPB-130 40A-130V 40A/CL-120-130 40R14/N 40S11N/IF 120V 40T6-1/2/2 120V 40T8 115-125V 40T10-120-130V 40A/99 (120,130) 40B101/2 (120) 40B101/2/W (120) 40BA9C (120) 40BA9C/F (120) 40BA91/2 (120) 40BA91/2/(120) 40F15 (120) 40S11N/IF (120) 50A (12,34) — 50A/RS/TF (120) 50/150T/SW (120) 60A19/35-130V 60A/TF (120) 60B101/2 (120) 60BA9C (120) For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B 1-27 Incandescent Lamps NOTES \ 1-28 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage B Halogen Lamps HALOGEN PAR38 LAMPS Retail HIR™ & Silv-IR .............................................................................................................. 2-5 HIR XL® (UltraLong Life) ....................................................................................................... 2-5 HIR™ ............................................................................................................................................. 2-5 Silver Saver™ ........................................................................................................................... 2-6 Long Life PAR38...................................................................................................................... 2-6 Halogen Plus ............................................................................................................................ 2-6 Standard Halogen ................................................................................................................ 2-7 Cool Beam PAR38 .................................................................................................................. 2-7 Quartzline® .............................................................................................................................. 2-7 HALOGEN COMPACT PAR LAMPS Compact HIR™ ........................................................................................................................ 2-7 Compact PAR30 Long Neck .............................................................................................. 2-7 Compact PAR30 ..................................................................................................................... 2-8 Compact PAR20 ..................................................................................................................... 2-8 Halogen Compact PAR16 .................................................................................................. 2-8 Diamond Precise® Electronic MR16 .............................................................................. 2-9 PAR36 ....................................................................................... 2-9 A-LINE/DECORATIVE ............................................................2-10 A A-15 ............................................................................................................................................. 2-9 A-19 ............................................................................................................................................. 2-9 A-21 ............................................................................................................................................. 2-9 Halogen Reflectors ............................................................................................................... 2-9 G16.5 GC .................................................................................................................................... 2-9 G16.5 GM .................................................................................................................................2-10 A111........................................................................................2-11 MR Turn & Lock ConstantColor® ..........................................................................................2-11 ConstantColor® Precise™ Cover Glass MR16 ...........................................................2-11 ConstantColor® Precise™ MR16 .....................................................................................2-12 Precise™ Cover Glass IR MR16 .......................................................................................2-13 Standard MR16 .....................................................................................................................2-13 Standard MR11 .....................................................................................................................2-13 120V MR16 .............................................................................................................................2-13 QUARTZ HALOGEN ...............................................................2-14 QUARTZLINE® HIR™ ...........................................................................................................................................2-14 Halogen....................................................................................................................................2-15 AIRPORT .................................................................................2-18 TUBULAR QUARTZ HEAT......................................................2-19 GENERAL INFORMATION ....................................................2-21 OPERATING NOTES ...............................................................2-21 FOOTNOTES ...........................................................................2-22 CROSS REFERENCE ..............................................................2-23 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 2-1 Halogen Lamps BULB IDENTIFICATION DIA. in.: Diameter of bulb at widest point. MOL in.: Maximum Overall Length including base or pins. LCL in.: Distance between the center of the filament and the Light Center Length reference plane. Note: Lamp drawings are not drawn to scale. Be sure to check size and dimension information when identifying each lamp. DIA. MOL To convert inches to millimeters, multiply the dimension (in inches) by 25.4 (i.e. 1.5’’ x 25.4 = 38.1 mm). FILAMENT IDENTIFICATION C-8 CC-8 C-2V CC-2V C-6 CC-6 C-8 CC-8 C-6 Oval BASE IDENTIFICATION 2-Pin (Round) GX5.3 2-Pin GU4 Med Screw E26 2-2 Can DC Bay 2-Pin GU5.3 2-Pin GY6.35 2-Pin G4 Mog Screw E39 Recessed Single Contact R7s Turn & Lock GU7 Mogul BiPost G38 Screw Terminals GU10 4’’ Leads G8 Ext. Mog End Pr GX16d G9 Mog End PR GX16d 1’’ Ribbon Leads 2-Pin Pf Min Screw E10 Med Skirted E26/50x39 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 6’’ Flex Leads DC Bay BA15d Min Cand E11 Halogen Lamps INTRODUCTION Halogen lamps provide a small, white light source with excellent color rendering. Unlike standard incandescent lamps, halogen lamps use a halogen gas which allows the bulbs to burn longer without sacrificing light output. Compared to incandescent lamps, halogen lamps provide: • Crisp, white light • Excellent beam control • Compact size • High lumen maintenance • Long life PRODUCT INFORMATION PAR38* VS. STANDARD HALOGEN Compact PAR Halogen (PAR20/PAR30) (pg 2-8) • Small size for “low profile” fixture • Energy efficient replacement for R20/R30 lamps • Long life – 3000 hours Retail HIR™ (PAR38) (pg 2-5) • Up to 42% more efficient • Up to 27% energy savings • Up to 60% longer life – 4000 hours Diamond Precise® Electronic (MR16)◊ (pg 2-9) • • • • HIR XL® UltraLong Life (PAR38) (pg 2-5) • Up to 13% energy savings • Ultra long life – 6000 hours HIR™ (PAR38) (pgs 2-5 to 2-6) 58% energy savings vs 50PAR20/50R20 2X longer life than 50PAR20/50R20 – 5000 hours Precise beam control, 90% lumen maintenance 120V Edison base, fully dimmable MR • Up to 28% more efficient • Up to 22% energy savings • Up to 20% longer life – 3000 hours Turn & Lock (TAL) ConstantColor® (MR16) (pg 2-11) • • • • ™ Silver Saver (PAR38) (pg 2-6) • Up to 14% more efficient • Up to 12% energy savings • Up to 20% longer life – 3000 hours User-friendly base… easy to install and remove Over 90% maintained light over life Virtually no color shift Suitable for use in open fixtures ConstantColor® Precise™ Cover Glass (MR16) (pgs 2-11 to 2-12) • Cover glass lens protects bulb from dust and dirt • Suitable for use in open fixtures Halogen Plus (PAR38) (pgs 2-6 to 2-7) • Longer life than standard halogen – 2500 hours • Wide variety of wattages and beam spreads ConstantColor® Precise™ (MR16) (pg 2-12) • • • • Standard Halogen (PAR38) (pg 2-7) • Crisp, white light • Life – 2000 hours Quartzline® (PAR38) (pg 2-7) Precise beam control No color shift Over 90% maintained light output over life Long life – up to 6000 hours (50-watt) Precise™ Cover Glass IR (MR16) (pg 2-13) • High light output for long throws (250 watt) • Long life – 4200 hours • Energy saving MR16 • 4000 hour lamp life COMPACT PAR Standard MR (MR16/MR11) (pgs 2-13 to 2-14) Compact HIR™ (PAR30) (pg 2-7) • Small size for “low profile” look • Crisp, white light • Most efficient PAR30 • Long life – 4000 hours LINEAR QUARTZ Long Neck PAR30 Halogen (PAR30L) (pgs 2-7 to 2-8) Linear Quartzline® HIR™ (pgs 2-14 to 2-15) • Energy efficient replacement for R30 lamps • Ideal for recessed fixtures * All comparisons made against standard and Halogen Plus at same/similar lumen output. • 30%-40% energy cost savings vs. standard quartz lamps • 95% maintained light output over life • Cooler operation increases fixture life ◊ Although face lumens are 53% less, the multi-faceted reflector concentrates lumens on target, diminishing extraneous light. For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 2-3 Halogen Lamps HEADINGS IN THIS CATALOG SECTION The following terms and descriptions can help you when checking Halogen lamp specifications and when ordering products. Within each product line, lamps are divided into families. Within families, lamps are listed by wattage. In each of these groups, lamps are listed alphabetically by bulb shape. LCL in.: MOL in.: Maximum Overall Length in inches. Distance between the center of the filament and the Light Center Length reference plane, in inches. Filament Design: Life - Hours: Filaments are designated by a letter combination in which C is a coiled wire filament, CC is a coiled wire that is itself wound into a larger coil, and SR is a straight ribbon filament. Numbers represent the type of filament-support arrangement. Life (as defined by FTC Lamp Label Rules) is rated life in hours. Light Output - Lumens: Case Quantity: Energy Used - Nominal Watts: Light output (as defined by FTC Lamp Label Rules) is rated lumens. Number of product units packed in a case. Energy Used (as defined by FTC Lamp Label Rules). To estimate energy consumption (kWh), multiply watts x hours of use and divide by 1000. Reference Color Temperature Kelvins (K): “Warmth” or “Coolness” of the lamp, measured in Kelvins (K). The higher the temperature, the cooler the appearance of the light. Volts: Lamp data is based on operation at rated voltage. Bulb Shape: Bulb shape followed by its size (the maximum diameter of the bulb expressed in eighths of an inch). Bulb Shape Approximate CBCP (Center Beam Candlepower): Order Code: For reflector type lamps. Center Beam Candlepower is the intensity (candelas) at the center or maximum intensity of the beam. It is important to use this five-digit code when ordering to ensure that you receive the exact product you require. Additional Information Base: Lamp Description: The type of base. The lamp‘s identification code. Base Type Order Watts Code Description Typical application and/or other important information. Rated Initial Case Filament Life Lumens Color Volts Qty. Type MOL LCL (hrs) Initial Temp. CBCP Footnotes Additional Information HALOGEN PAR38 LAMPS HIR™ PAR38 Med Skirt 50 12396 50PAR/HIR/SP9 120 12 CC-8 5.31 3000 800 2810 16000 B 1a, 2a, 4f, 9a, 10c Spotlight 50 PAR / HIR / SP 9 Identifies the lamp’s wattage. Identifies the lamp shape and the bulb diameter in eighths of inches. Identifies the lamp type. Identifies beam angle, code may also include packaging information. HALOGEN BRAND NAME CROSS-REFERENCE Identifies as Spotlight. GE Retail HIR™ HIR/XL™ PAR HIR™ PAR Silver Saver™ Edison™ Halogen Plus PAR Standard Halogen PAR Compact PAR Diamond Precise® Turn & Lock (TAL) ConstantColor® ConstantColor® Precise™ Precise™ IR Standard MR16 Halogen A-Line WHEN YOU DON’T KNOW THE LAMP DESCRIPTION 1. Identify bulb shape next to lamp information. 2. Measure bulb diameter using ruler in Appendix section page A-1 to determine width in eighths of an inch. 3. Identify base type using table on page 2-2. 4. Find your lamp in the table containing the bulb shape, size and base, which are all listed by wattage. OSRAM/SYLVANIA — — Capsylite® PAR IR™ — — Capsylite® PAR — Capsylite® PAR — — Tru-Aim Titan® Tru-Aim® IR™ Tru-Aim® Capsylite® A-Line (Midbreak) PHILIPS — — Masterline™ IRC — — Masterline™ 2500 Masterline™ 2000 Masterline™ PAR — — Continuum Color® Masterline™ ES IRC Continuum® Halogena® ATTENTION: This brand-name cross reference chart is provided only as a quick reference. Other lamp company brand listings may only represent a near equivalent, versus an identical match to GE Lighting brands. Individual lamp manufacturers’ performance specifications should be consulted. Lamp performance may be affected by environmental conditions, and/or other auxiliary equipment. 2-4 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Halogen Lamps Bulb Shape Base Type Order Watts Code Description Rated Initial Case Filament Life Lumens Color Volts Qty. Type MOL LCL (hrs) Initial Temp. CBCP Footnotes Additional Information Spotlight Floodlight Spotlight - Heavy Duty Filament Floodlight - Heavy Duty Filament Spotlight Floodlight Spotlight - Heavy Duty Filament Floodlight - Heavy Duty Filament Spotlight Floodlight HALOGEN PAR38 LAMPS RETAIL HIR™ & SILV-IR PAR38 Med Skirt 45 16344 45PAR/HIR/R/SP10 120 12 16345 45PAR/HIR/R/FL25 120 12 50 46168 50PAR/HIR/S/SP10 120 12 5.31 5.31 5.31 4000 4000 4000 800 2750 14000 800 2750 3400 800 2750 14000 120 12 5.31 4000 800 2750 55 16346 55PAR/HIR/R/SP10 120 12 16347 55PAR/HIR/R/FL25 120 12 60 46165 60PAR/HIR/S/SP10 120 12 5.31 5.31 5.31 4000 1050 2800 17000 4000 1050 2800 4000 4000 1050 2800 17000 120 12 5.31 4000 1050 2800 90 16348 90PAR/HIR/R/SP10 120 12 16349 90PAR/HIR/R/FL25 120 12 5.31 5.31 4000 2030 2850 30000 4000 2030 2850 7000 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c B B 1a, 2a, 4f, 9a, 10c 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c B B 1a, 2a, 4f, 9a, 10c 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 46167 50PAR/HIR/S/FL25 46166 60PAR/HIR/S/FL30 3400 2800 HIR XL® (ULTRALONG LIFE) PAR38 PAR38 Med Skirt 45 40793 45PAR/HIR/SP12XL 40790 45PAR/HIR/FL40XL 55 40794 55PAR/HIR/SP12XL 40792 55PAR/HIR/FL40XL 90 40795 90PAR/HIR/SP12XL 40791 90PAR/HIR/FL40XL 120 120 120 120 120 120 6 CC-8 6 CC-8 6 CC-8 6 CC-8 6 CC-8 6 CC-8 5.31 5.31 5.31 5.31 5.31 5.31 6000 600 2680 7000 6000 600 2680 1300 6000 800 2680 9000 6000 800 2680 2000 6000 1470 2800 17000 6000 1470 2800 2800 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c B Spotlight Floodlight Spotlight Floodlight Spotlight Floodlight 50 40937 50PAR/HIR/SP6 12396 50PAR/HIR/SP9 12397 50PAR/HIR/FL25 50 22850 50PAR/HIR/FL25 46 60 11881 60PAR/HIR/SP10 18627 60PAR/HIR/SP10 60 18629 60PAR/HIR/SP10 54 60 11878 60PAR/HIR/FL30 18626 60PAR/HIR/FL30 60 18628 60PAR/HIR/FL30 54 60 10467 60PAR/HIR/FL40 20947 60PAR/HIR/WFL 60 20948 60PAR/HIR/WFL 54 70 46367 70PAR/HIR/SP10 70 46369 70PAR/HIR/SP10 64 70 46368 70PAR/HIR/FL25 70 46370 70PAR/HIR/FL25 64 70 16239 70PAR/HIR/FL/CON 80 27216 80PAR/HIR/SP10 27217 80PAR/HIR/SP12 27218 80PAR/HIR/FL25 120 120 120 130 120 120 120 130 120 120 120 130 120 120 120 130 120 120 130 120 120 130 120 120 120 120 120 12 CC-8 12 CC-8 12 CC-8 12 CC-8 5.31 5.31 5.31 5.31 3000 3000 3000 3000 6000 3000 3000 3000 6000 3000 3000 3000 6000 3000 3000 3000 6000 3000 3000 6000 3000 3000 6000 3000 3000 3000 3000 Spotlight Spotlight Floodlight Floodlight 4700 4700 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c B 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c B 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c B 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c B 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 2900 4700 2900 22000 2900 17500 2900 5000 1a, 2a, 4f, 9a, 10c 1a, 2a, 4f, 9a, 10c 1a, 2a, 4f, 9a, 10c 1a, 2a, 4f, 9a, 10c HIR™ PAR38 Med Skirt 6 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 6 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 6 CC-8 12 CC-8 12 CC-8 12 CC-8 5.31 5.31 5.31 5.31 800 800 800 800 600 1050 1050 1050 800 1050 1050 1050 800 1050 1050 1050 800 1260 1260 950 1260 1260 950 1260 1500 1500 1500 2810 20000 2810 16000 2810 3400 2810 3400 2850 17000 2850 17000 2850 17000 2850 2850 2850 2800 2800 2800 2850 2850 2850 1700 2900 19000 2900 19000 2900 2900 B B B For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Spotlight Spotlight Spotlight Floodlight Floodlight Floodlight Floodlight Wide Floodlight Wide Floodlight Spotlight Spotlight Floodlight Floodlight Floodlight Spotlight Spotlight Floodlight 2-5 Halogen Lamps Bulb Shape Base Type Order Watts Code Description Rated Initial Case Filament Life Lumens Color Volts Qty. Type MOL LCL (hrs) Initial Temp. CBCP Footnotes Additional Information HALOGEN PAR38 LAMPS (CONTINUED) HIR™ (CONTINUED) PAR38 Med Skirt 100 18635 100PAR/HIR/SP10 11885 100PAR/HIR/SP10 100 18636 100PAR/HIR/SP10 88 100 11883 100PAR/HIR/FL25 18631 100PAR/HIR/FL25 100 18633 100PAR/HIR/FL25 88 100 10473 100PAR/HIR/FL40 120 120 130 120 120 120 130 120 120 12 CC-8 5.31 6 CC-8 5.31 12 CC-8 5.31 3000 3000 3000 6000 3000 3000 3000 6000 3000 2030 2030 2030 1470 2030 2030 2030 1470 2030 2900 30000 2900 30000 2900 30000 53 16338 53PAR/H/SS/SP10 16339 53PAR/H/SS/FL25 53 27989 53/PAR/HSS/SP10 47 53 27991 53/PAR/HSS/FL25 47 66 16340 66PAR/H/SS/SP10 16341 66PAR/H/SS/FL25 66 28263 66/PAR/HSS/SP10 58 66 28265 66PAR/HSS/FL25 58 79 16342 79PAR/H/SS/SP10 16343 79PAR/H/SS/FL25 79 28267 79PAR/HHS/SP10 70 79 28268 79PAR/HSS/FL25 70 120 120 130 120 130 120 120 120 130 120 130 120 120 120 130 120 130 120 12 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 3000 3000 3000 6000 3000 6000 3000 3000 3000 6000 3000 6000 3000 3000 3000 6000 3000 6000 45 16354 45PAR/SP10 XL-EG 16355 45PAR/FL25 XL-EG 90 16357 90PAR/SP10 XL-EG 16358 90PAR/FL25 XL-EG 45 20757 45PAR/SP10XL-OD 20758 45PAR/FL25XL-OD 90 20759 90PAR/SP10XL-OD 20763 90PAR/FL25XL-OD 120 120 120 120 120 120 120 120 5.31 5.31 5.31 5.31 5.31 5.31 5.31 5.31 45 17470 45PAR/H/SP10 45 16229 45PAR/H/SP10 40 45 17471 45PAR/H/FL25 6PK 45 16231 45PAR/H/FL25 40 60 25266 60PAR/H/SP10 60 25270 60PAR/H/SP10 54 60 25269 60PAR/H/FL25 60 25271 60PAR/H/FL25 54 120 130 120 120 130 120 120 130 120 120 130 120 6 CC-8 5.31 12 CC-8 5.31 6 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 2900 2900 2900 7000 7000 7000 2900 3400 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c B 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c B B 1a, 2a, 4f, 9a, 10c 800 800 800 608 800 608 1050 1050 1050 800 1050 800 1310 1310 1310 1000 1310 1000 2800 14000 2800 2900 2800 14000 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c Spotlight Floodlight Spotlight 2900 1a, 2a, 4f, 9a, 10c Floodlight 2850 18000 2850 4000 2850 18000 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c Spotlight Floodlight Spotlight 4000 1a, 2a, 4f, 9a, 10c Floodlight 2850 20000 2850 4700 2850 20000 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c Spotlight Floodlight Spotlight 4700 1a, 2a, 4f, 9a, 10c Floodlight 6000 6000 6000 6000 6000 6000 6000 6000 520 520 1310 1310 520 520 1310 1310 2700 8000 2700 2000 2800 20000 2800 4700 2700 8000 2700 2000 2800 20000 2800 4700 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c Spotlight Floodlight Spotlight Floodlight Spotlight Floodlight Spotlight Floodlight 2500 2500 5000 2500 2500 5000 3000 3000 6000 3000 3000 6000 540 540 410 540 540 410 800 800 608 800 800 608 2750 2750 8000 8000 2750 2750 2000 2000 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B SILVER SAVER™ PAR38 Med Skirt 12 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 2800 2850 2850 Spotlight Spotlight Spotlight Floodlight Floodlight Floodlight Floodlight LONG LIFE PAR38 PAR38 Med Skirt 6 CC-8 6 CC-8 6 CC-8 6 CC-8 6 CC-8 6 CC-8 6 CC-8 6 CC-8 1a, 2a, 4f, 9a, 10c 1a, 2a, 4f, 9a, 10c 1a, 2a, 4f, 9a, 10c HALOGEN PLUS PAR38 Med Skirt 2-6 6 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 12 CC-8 5.31 2800 13000 2800 13000 2800 2800 3200 3200 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Spotlight Spotlight Floodlight Floodlight Spotlight Spotlight Floodlight Floodlight Halogen Lamps Bulb Shape Base Type Order Watts Code Description Rated Initial Case Filament Life Lumens Color Volts Qty. Type MOL LCL (hrs) Initial Temp. CBCP Footnotes Additional Information HALOGEN PAR38 LAMPS (CONTINUED) HALOGEN PLUS (CONTINUED) PAR38 Med Skirt 75 14751 75PAR/H/SP9-6PK 14748 75PAR/H/FL25-6PK 81864 75PAR38HFL25/RVL 26564 75PAR/H/FL-TWIN 75 21389 75PAR/H/FL25 66 90 17450 90PAR/H/SP10-6PK 90 13311 90PAR/H/SP10 79 90 17451 90PAR/H/FL25-6PK 90 13308 90PAR/H/FL25 79 90 22742 90PAR/H/FL-TWIN 25727 90PAR/H/WFL-120V 120 41632 120PAR/H/SP9 120 41631 120PAR/H/FL30 120 120 120 120 130 120 120 130 120 120 130 120 120 120 120 120 6 CC-8 6 CC-8 6 CC-8 3 CC-8 12 CC-8 5.31 5.31 5.31 5.31 5.31 5.31 5.31 5.31 5.31 2500 2500 2500 2500 2500 5000 2500 2500 5000 2500 2500 5000 2500 2500 2500 2500 1050 1050 950 1050 1050 800 1310 1310 1000 1310 1310 1000 1310 1310 1900 1900 120 6 CC-8 5.31 120 6 CC-8 5.31 120 3 CC-8 5.31 130 12 CC-8 5.31 120 120 6 CC-8 5.31 120 6 CC-8 5.31 120 3 CC-8 5.31 130 12 CC-8 5.31 120 2000 2000 2000 2000 4000 2000 2000 2000 2000 4000 600 600 600 600 450 1500 1500 1500 1500 1150 120 12 CC-8 5.31 2500 1260 2870 250 23719 Q250PAR/SP10 120 12 CC-8 5.31 4200 3600 2880 40000 23718 Q250PAR/FL30 120 12 CC-8 5.31 4200 3600 2880 120 120 120 120 120 130 120 120 130 120 6000 6000 6000 4000 4000 3000 6000 4000 3000 6000 620 620 620 825 825 825 620 825 825 620 2810 2810 1800 1800 3000 6000 3000 6000 580 2800 460 580 2800 460 7500 6 CC-8 5.31 12 CC-8 5.31 6 CC-8 5.31 12 CC-8 5.31 3 CC-8 12 CC-8 6 CC-8 6 CC-8 2850 18000 2850 4000 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c 2850 2850 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 4000 4000 2900 20000 2900 20000 2900 2900 4700 4700 Spotlight Floodlight Reveal®, Floodlight Floodlight Floodlight Spotlight Spotlight Floodlight Floodlight 2900 4700 2900 2950 18000 2950 4000 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c 2750 2750 2750 2750 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c B 2a, 4f, 9a, 10c B 1a, 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c B 1a, 2a, 4f, 9a, 10c B Spotlight Floodlight Floodlight Floodlight B 1a, 2a, 2c, 4f, 9a, 10c Cool Beam Flood 1a, 2a, 4f, 9a, 10c Floodlight Wide Floodlight Narrow Spot Floodlight STANDARD HALOGEN PAR38 Med Skirt 50 17980 50PAR/H/SP10-6PK 17979 50PAR/H/FL25-6PK 25948 50PAR/H/FL-TWIN 50 17926 50PAR/H/FL 46 100 17992 100PAR/H/SP10 17986 100PAR/H/FL25 25679 100PAR/H/FL/TWIN 100 17947 100PAR/H/FL25 88 9500 2200 2200 2200 2900 22000 2900 5000 2900 5000 2900 5000 Spotlight Floodlight Floodlight Floodlight COOL BEAM PAR38 PAR38 Med Skirt 90 17691 90PAR/CB/H/FL25 4100 ® QUARTZLINE PAR38 Med Skirt 9000 1a, 2a, 2j, 4b, 4f, 4g, 4h, 9a, 10c 1a, 2a, 2j, 4b, 4f, 4g, 4h, 9a, 10c Spotlight Floodlight HALOGEN COMPACT PAR LAMPS COMPACT HIR™ PAR30 Med 45 41545 45PAR30HIR/SP9XL 41547 45PAR30HIR/FL25XL 41550 45PAR30HIR/FL35XL 50 19902 50PAR30/HIR/SP9 19901 50PAR30HIR/FL25 50 21533 50PAR30HIR/FL25 46 50 19900 50PAR30/HIR/FL35 50 19903 50PAR30/HIR/FL35 46 15 CC-8 15 CC-8 15 CC-8 15 CC-8 15 CC-8 15 CC-8 3.62 3.62 3.62 3.62 3.62 3.62 15 CC-8 3.62 15 CC-8 3.62 2680 9750 2680 2025 2680 1125 2810 15000 2810 3200 2810 3200 2a, 4f, 4h, 9a, 10c B 1a, 1a, 2a, 4f, 4h, 9a, 10c B 1a, 2a, 4f, 4h, 9a, 10c B 1a, 2a, 4f, 4h, 9a, 10c B 1a, 2a, 4f, 4h, 9a, 10c B 1a, 2a, 4f, 4h, 9a, 10c B 2a, 4f, 4h, 9a, 10c B 1a, 1a, 2a, 4f, 4h, 9a, 10c B Spotlight Floodlight Floodlight Spotlight Floodlight Floodlight B 1a, 2a, 4f, 4h, 9a, 10c B 1a, 2a, 4f, 4h, 9a, 10c Spotlight Floodlight Floodlight COMPACT PAR30 LONG NECK PAR30L Med 50 14940 50PAR30L/H/SP10 46 50 11117 50PAR30L/H/SP10 46 130 6 CC-8 4.75 120 130 15 CC-8 4.75 120 7500 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Spotlight 2-7 Halogen Lamps Bulb Shape Base Type Order Watts Code Description Rated Initial Case Filament Life Lumens Color Volts Qty. Type MOL LCL (hrs) Initial Temp. CBCP Footnotes Additional Information HALOGEN COMPACT PAR LAMPS (CONTINUED) COMPACT PAR30 LONG NECK (CONTINUED) PAR30L Med 50 11116 50PAR30L/H/FL40 120 50 11123 50PAR30L/H/FL40 130 46 120 50 14941 50PAR30L/H/WFL 120 75 11124 75PAR30L/H/SP10 120 75 11129 75PAR30L/H/SP10 130 66 120 75 14943 75PAR30L/H/FL25 120 75 11131 75PAR30L/H/FL25 130 66 120 75 16393 75PAR30L/H/WFL 120 81862 75PAR30LHFL25/RVL 120 15 CC-8 4.75 15 CC-8 4.75 50 14023 50PAR30/H/SP10 50 17870 50PAR30/H/SP10 46 50 17871 50PAR30/H/FL25 50 17872 50PAR30/H/FL25 46 50 14022 50PAR30/H/FL35 50 17874 50PAR30/H/FL35 46 60 27212 60PAR30/H/NSP9 40167 60PAR30/H/FL25 27214 60PAR30/H/FL35 75 14802 75PAR30/H/SP10 81863 75PAR30HFL35/RVL 75 18056 75PAR30/H/SP10 66 75 18057 75PAR30/H/FL25 14779 75PAR30/H/FL35 75 18060 75PAR30/H/FL35 66 120 130 120 120 130 120 120 130 120 120 120 120 120 120 130 120 120 120 130 120 6 CC-8 3.62 15 CC-8 3.62 50 14927 50PAR20/H/SP10 81861 50PAR20HFL25/RVL 50 17866 50PAR20/H/SP10 46 50 14928 50PAR20H/FL25 50 17868 50PAR20/H/FL25 46 120 6 CC-8 3.13 120 6 CC-8 3.13 130 15 CC-8 3.13 120 120 6 CC-8 3.13 130 15 CC-8 3.13 120 2500 2500 2500 5000 2500 2500 5000 35 82135 35PAR16CURIO-PQ 60 41628 60PAR16/H/SP10 41623 60PAR16/H/FL30 82142 60PAR16FL/RVL-CD 120 120 120 120 6 CC-8 6 CC-8 6 CC-8 6 CC-8 2.88 2.88 2.88 2.88 75 41630 75PAR16/H/SP10 41629 75PAR16/H/FL30 120 120 6 CC-8 2.88 6 CC-8 2.88 6 CC-8 4.75 15 CC-8 4.75 15 CC-8 4.75 6 CC-8 4.75 15 CC-8 4.75 6 CC-8 4.75 6 CC-8 4.75 3000 580 3000 580 6000 460 3000 630 3000 940 3000 940 6000 751 3000 940 3000 940 6000 751 3000 1050 3000 980 2800 2800 1100 1100 3000 3000 6000 3000 3000 6000 3000 3000 6000 3000 3000 3000 3000 3000 3000 6000 3000 3000 3000 6000 2800 2800 8200 8200 2800 2800 2300 2300 2800 2800 1400 1400 2800 2830 13000 2830 13000 2830 2830 3800 3800 2830 2a, 4f, 4h, 9a, 10c B 1a, 1a, 2a, 4f, 4h, 9a, 10c B 2a, 4f, 4h, 9a, 10c B 1a, 1a, 2a, 4f, 4h, 9a, 10c B 1a, 2a, 4f, 4h, 9a, 10c B Floodlight Floodlight 2a, 4f, 4h, 9a, 10c B 1a, 1a, 2a, 4f, 4h, 9a, 10c B 2a, 4f, 4h, 9a, 10c B 1a, 1a, 2a, 4f, 4h, 9a, 10c Floodlight Floodlight 2a, 4f, 4h, 9a, 10c B 1a, 1a, 2a, 4f, 4h, 9a, 10c B 2a, 4f, 4h, 9a, 10c B 1a, 1a, 2a, 4f, 4h, 9a, 10c B 2a, 4f, 4h, 9a, 10c B 1a, 1a, 2a, 4f, 4h, 9a, 10c B 2a, 4f, 4h, 9a, 10c B 1a, 1a, 2a, 4f, 4h, 9a, 10c B 1a, 2a, 4f, 4h, 9a, 10c B 1a, 2a, 4f, 4h, 9a, 10c B 1a, 2a, 4f, 4h, 9a, 10c Spotlight Spotlight Wide Floodlight Spotlight Spotlight Wide Floodlight Reveal®, Floodlight COMPACT PAR30 PAR30 Med 15 CC-8 3.62 15 CC-8 3.62 6 CC-8 3.62 15 CC-8 3.62 15 CC-8 15 CC-8 15 CC-8 6 CC-8 6 CC-8 15 CC-8 3.62 3.62 3.62 3.62 3.62 3.62 15 CC-8 3.62 6 CC-8 3.62 15 CC-8 3.62 630 630 500 630 630 500 630 630 500 800 800 800 1030 1010 1030 790 1030 1030 1030 790 2800 11000 2800 2900 2800 1700 2830 13000 2830 13000 Floodlight Floodlight Floodlight Floodlight Spotlight Floodlight Floodlight Spotlight Reveal®, Floodlight 1a, 2a, 4f, 4h, 9a, 10c Spotlight B 2a, 4f, 4h, 9a, 10c B 1a, 1a, 2a, 4f, 4h, 9a, 10c B 1a, 2a, 4f, 4h, 9a, 10c B 2830 2830 2830 3800 2400 2400 570 2800 6000 2a, 4f, 4h, 9a, 10c B 1a, 1a, 2a, 4f, 4h, 9a, 10c 570 2800 498 570 2800 570 2800 498 6000 B 2a, 4f, 4h, 9a, 10c B 1a, 1a, 2a, 4f, 4h, 9a, 10c B 3000 2000 2000 2000 650 2950 650 2950 5400 1550 2000 2000 900 2950 900 2950 6200 1600 Floodlight Floodlight Floodlight COMPACT PAR20 PAR20 Med 1500 1500 Spotlight Reveal®, Floodlight 1a, 2a, 4f, 4h, 9a, 10c Spotlight Floodlight Floodlight HALOGEN COMPACT PAR16 PAR16 Med 2-8 1a, 2a, 4f, 4h, 9a, 10c 1a, 2a, 4f, 4h, 9a, 10c Spotlight 1a, 2a, 4f, 4h, 9a, 10c Floodlight 1a, 2a, 4f, 4h, 9a, 10c Reveal®, Floodlight, Carded 1a, 2a, 4f, 4h, 9a, 10c Spotlight 1a, 2a, 4f, 4h, 9a, 10c Floodlight For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Halogen Lamps Bulb Shape Base Type Order Watts Code Description Rated Initial Case Filament Life Lumens Color Volts Qty. Type MOL LCL (hrs) Initial Temp. CBCP Footnotes Additional Information HALOGEN COMPACT PAR LAMPS (CONTINUED) DIAMOND PRECISE® ELECTRONIC MR16 MR16 Med 21 48545 Q21EMR16/C/SP12 120 6 C-6 3.38 5000 260 2950 3900 48546 Q21EMR16/C/FL25 120 6 C-6 3.38 5000 260 2950 890 48547 Q21EMR16/C/ SP12CD 48548 Q21EMR16/C/ FL25CD 120 6 C-6 3.38 5000 260 2950 3900 120 6 C-6 3.38 5000 260 2950 890 35 19873 35PAR36/H/SP5 19876 35PAR36/H/SP8 19877 35PAR36/H/FL30 42072 35PAR36/H/VWFL 50 19878 50PAR36/H/SP5 19879 50PAR36/H/SP8 19880 50PAR36/H/FL30 12 12 12 12 12 12 12 12 C-6 12 C-6 12 C-6 12 C-6 12 C-6 12 C-6 12 C-6 2.75 2.75 2.75 2.75 2.75 2.75 2.75 4000 4000 4000 4000 4000 4000 4000 250 250 250 250 400 400 400 40 82114 40A15CF/CL/H-CD2 120 6 CC-8 3.50 2250 60 82115 60A15CF/CL/H-CD2 120 6 CC-8 3.50 2250 60 82137 60A/CL/H/RVL-CD 120 5 C-8 4.43 3000 675 75 82138 75A/CL/H/RVL-CD 120 5 C-8 4.43 3000 850 100 82139 100A/CL/H/RVL-CD 120 5 C-8 4.43 3000 1275 30 24699 30/100-HALOGEN 70 100 50 81590 50/150-HALOGEN 100 150 120 6 CC-8 5.25 120 6 CC-8 5.25 60 85116 60BR30FL/H-PQ1/6 120 6 CC-8 5.37 3000 700 120 6 CC-8 5.37 3000 700 60 85131 60BR40FL/H-PQ1/6 120 6 CC-8 6.56 3000 790 100 85146 100BR40F/H-PQ1/6 120 6 CC-8 6.56 3000 1200 1c, 2a, 2b, 4f, 4i, B 1a, 4k, 9b, 10c 1c, 2a, 2b, 4f, 4i, B 1a, 4k, 9b, 10c 1c, 2a, 2b, 4f, B 1a, 4i, 4k, 9b, 10c 1c, 2a, 2b, 4f, 4i, B 1a, 4k, 9b, 10c Narrow Spot Narrow Flood Narrow Spot, Carded Narrow Flood, Carded PAR36 PAR36 Scrw Term 3050 25000 3050 8000 3050 900 3050 3050 39000 3050 10000 3050 1300 2b, 4f, 4g, 7a, 9b, 10c Spotlight B 2a, 2a, 2b, 4f, 4g, 7a, 9b, 10c Spotlight B 2a, 2b, 4f, 4g, 7a, 9b, 10c Floodlight B 2a, 2b, 4f, 4g, 7a, 9b, 10c Wide Flood B 2a, 2b, 4f, 4g, 7a, 9b, 10c Spotlight B 2a, 2b, 4f, 4g, 7a, 9b, 10c Spotlight B 2a, 2b, 4f, 4g, 7a, 9b, 10c Floodlight B A-15 A15 Med 1a, 1b, 2a, 2b, 2e, 4i, 4j, 7a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 7a, 10b, 10c Celing Fan, Halogen Celing Fan, Halogen A-19 A19 Med 1a, 1b, 2a, 2b, 2e, 4i 4j, 7a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i 4j, 7a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i 4j, 7a, 10b, 10c Reveal®, Halogen 1a, 2a, 2b, 2c, 4i, 4j 9a, 10b, 10c 3-Way 1a, 2a, 2b, 2c, 4i, 4j 9a, 10b, 10c 3-Way 1a, 1b, 2a, 2b, 2e, 4i 4j, 7a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i 4j, 7a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i 4j, 7a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i 4j, 7a, 10b, 10c Halogen Reflector Reveal®, Halogen Reveal®, Halogen A-21 A21 Med 2500 300 1050 1370 2500 700 1600 2300 HALOGEN REFLECTORS BR30 Med 85127 60BR30FL/H-3PK BR40 Med Halogen Reflector 3-Pack Halogen Reflector Halogen Reflector G16.5 GC G16.5 Cand 40 82131 40GC/CL/H-PQ2/3 120 6 CC-8 3.00 2250 60 82132 60GC/CL/H-PQ2/3 120 6 CC-8 3.00 2250 1a, 1b, 2a, 2b, 2e, 4i 4j, 7a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i 4j, 7a, 10b, 10c For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 2-9 Halogen Lamps Bulb Shape Base Type Order Watts Code Description Rated Initial Case Filament Life Lumens Color Volts Qty. Type MOL LCL (hrs) Initial Temp. CBCP Footnotes Additional Information G16.5 (CONTINUED) GM G16.5 Med 40 82133 40GM/CL/H-PQ2/3 120 6 CC-8 3.00 2250 1a, 1b, 2a, 2b, 2e, 4i 4j, 7a, 10b, 10cE 60 82134 60GM/CL/H-PQ2/3 120 6 CC-8 3.00 2250 1a, 1b, 2a, 2b, 2e, 4i 4j, 7a, 10b, 10cE A-LINE/DECORATIVE B13 Med 45 45650 45BM/HAL/PQ1/6 120 6 CC-8 4.63 2.38 3000 TB19 Med 50 16747 50TB/H 46 50 20647 50A/HAL 6PK 60 48105 60A/HAL/CD 48106 60A/HAL/CL/CD 75 48107 75A/HAL/CD 90 16745 90TB/H 81 90 20648 90A/HAL 6PK 48108 90A/HAL/CD 60 10036 60BTT/CL/CD 130 60 CC-8 4.43 120 120 6 CC-8 4.43 120 4 CC-8 4.43 120 4 CC-8 4.43 120 4 CC-8 4.43 130 60 CC-8 4.43 120 120 6 CC-8 4.43 120 4 CC-8 4.43 120 5 C-8 4.75 3.13 2000 4000 3.13 2000 2.62 3000 2.62 3000 2.62 3000 3.13 2000 4000 3.13 2000 2.62 3000 3.00 3000 11856 60BTT/CL/CD/TW 120 5 C-8 4.75 3.00 3000 900 2800 10038 60BTT/SW/CD 120 5 C-8 4.75 3.00 3000 840 2800 10039 60BTT/SW/CD/TW 120 5 C-8 4.75 3.00 3000 840 2800 BT14.5 Med 600 2750 710 540 710 840 870 1170 1580 1220 1580 1470 900 2800 2800 2800 2800 2850 2930 2930 2930 2800 75 10040 75BTT/SW/CD 120 5 C-8 4.75 3.00 3000 1070 2850 100 10042 100BTT/SW/CD 120 5 C-8 4.75 3.00 3000 1600 2900 150 10043 150BTT/SW/CD 120 5 C-8 4.75 3.00 3000 2430 2900 4.75 3.00 3000 900 2800 F14.5 Med 60 10044 60BTT/POST/CD 120 5 C-8 B10 Med 25 16760 25BM/H/CD2 120 5 CC-8 3.4 2.22 2250 280 2700 40 16761 40BM/H/CD2 120 5 CC-8 3.4 2.22 2250 485 2800 25 16764 25BC/H/CD2 120 5 CC-8 3.4 2.22 2250 280 2700 40 16765 40BC/H/CD2 120 5 CC-8 3.4 2.22 2250 485 2800 25 16766 25BFM/H/CD2 120 5 CC-8 3.4 2.22 2250 280 2700 40 16767 40/BFM/H/CD2 120 5 CC-8 3.4 2.22 2250 485 2800 40 16771 40G25/H/CL 120 6 CC-8 4.45 2.56 2250 510 2700 120 6 C-8 120 6 CC-8 4.45 120 6 C-8 Cand T10 G25 Med Med 82140 40G25/CL/H/RVL 60 16773 60G25/H/CL 82141 60G25/CL/H/RVL 2-10 4.50 2250 2.56 2250 1000 2900 4.50 2250 1a, 1b, 2a, 2b, 2e, 4i, Frost, Thick Glass 4j, 9a, 10b, 10c 1a, 2a, 4f, 4h, 9a, 10c Frost, Thick Glass B 2a, 4f, 4h, 9a, 10c B 1a, 1a, 2a, 4f, 4h, 9a, 10c Frost, Thick Glass Frost, Thick Glass 1a, 2a, 4f, 4h, 9a, 10c Clear, Thick Glass 1a, 2a, 4f, 4h, 9a, 10c Frost, Thick Glass 1a, 2a, 4f, 4h, 9a, 10c Frost, Thick Glass B 2a, 4f, 4h, 9a, 10c B 1a, 1a, 2a, 4f, 4h, 9a, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Frost, Thick Glass Frost, Thick Glass Clear, Brass Base, Carded Clear, Brass Base twin pack, Carded White, Brass Base, Carded White, Brass Base twin pack, Carded White, Brass Base, Carded White, Brass Base, Carded White, Brase Base, Carded Clear, Brass Base, Carded Postlamp Carded Twin Pack Carded Twin Pack Carded Twin Pack Carded Twin Pack Carded Twin Pack Carded Twin Pack Reveal® Halogen Reveal® Halogen Halogen Lamps Bulb Shape Base Type Order Watts Code Description Rated Initial Case Filament Life Lumens Color Volts Qty. Type MOL LCL (hrs) Initial Temp. CBCP Footnotes Additional Information A-LINE/DECORATIVE (CONTINUED) G25 T10 Med Med 40 16774 40G25/H/CRYSTAL 120 6 CC-8 4.45 2.56 2250 500 2700 60 16775 60G25/H/CRYSTAL 120 6 CC-8 4.45 2.56 2250 960 2900 25 16776 25T10/H/CD 120 4 CC-8 5.04 2.56 2250 260 2700 40 16777 40T10/H/CD 120 4 CC-8 5.04 2.56 2250 510 2700 60 16778 60T10/H/CD 120 4 CC-8 5.04 2.56 2250 800 2900 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c 1a, 1b, 2a, 2b, 2e, 4i, 4j, 9a, 10b, 10c Carded Carded Carded AR111 AR111 G53 35 97532 35AR111/SP8 12 10 2.64 2000 2800 14000 97533 35AR111/FL24 12 10 2.64 2000 2800 50 97534 50AR111/SP8 12 10 2.64 3000 2800 17800 97535 50AR111/FL24 12 10 2.64 3000 2800 75 97536 75AR111/SP8 12 10 2.64 3000 2900 23500 97537 75AR111/FL24 12 10 2.64 3000 2900 5300 97538 75AR111/FL45 12 10 2.64 3000 2900 1700 100 97539 100AR111/SP8 12 10 2.64 3000 2950 40000 97540 100AR111/FL24 12 10 2.64 3000 2950 8000 97541 100AR111/FL45 12 10 2.64 3000 2950 2300 35 30932 35MR16/Q/8/TL 12 10 C-6 2 3500 2900 8100 50 30901 50MR16/Q/10/TL 12 10 C-6 2 3500 3000 10800 30900 50MR16/Q/20/TL 12 10 C-6 2 3500 3000 3330 30899 50MR16/Q/40/TL 12 10 C-6 2 3500 3000 1395 12 20 C-6 1.88 5000 2900 3150 2a, 2b, 4f, 9a, 10c 20857 Q20MR16C/CG40 12 20 C-6 21456 FAM6Q20MR16NSCCG 12 1 C-6 1.88 1.88 5000 5000 2900 2900 475 3350 2a, 2b, 4f, 9a, 10c 2a, 2b, 4f, 9a, 10c 21455 FAM6Q20MR16FLCCG 12 1 C-6 1.88 5000 2900 490 2a, 2b, 4f, 9a, 10c 35 20864 Q35MR16/C/CG12 12 20 C-6 1.88 5000 3000 7500 2a, 2b, 4f, 9a, 10c 20860 Q35MR16C/CG20 12 20 C-6 1.88 5000 3000 3200 2a, 2b, 4f, 9a, 10c 2500 3500 2a, 2j, 4a, 4c, 4e, 4f 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f 9a, 9d, 10b, 10c Spotlight 2a, 2b, 4f, 7a, 9a, 10b, 10c 2a, 2b, 4f, 7a, 9a, 10b, 10c 2a, 2b, 4f, 7a, 9a, 10b, 10c 2a, 2b, 4f, 7a, 9a, 10b, 10c Narrow Spot Narrow Floodlight Spotlight Narrow Floodlight Spotlight Narrow Floodlight Wide Floodlight Spotlight Narrow Floodlight Wide Floodlight MR TURN & LOCK CONSTANTCOLOR® MR16 TAL Narrow Spot Narrow Flood Floodlight CONSTANTCOLOR® PRECISE™ COVER GLASS MR16 MR16 2-Pin GU5.3 20 20858 Q20MR16C/CG15 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Narrow Spot, ANSI: ESX Flood, ANSI: BAB Narrow Spot, Carded, ANSI: ESX Flood, Carded ANSI: BAB Narrow Spot, ANSI: FRB Spot, ANSI: FRA 2-11 Halogen Lamps Bulb Shape Base Type Order Watts Code Description Rated Initial Case Filament Life Lumens Color Volts Qty. Type MOL LCL (hrs) Initial Temp. CBCP Footnotes Additional Information MR (CONTINUED) CONSTANTCOLOR® PRECISE™ COVER GLASS MR16 (CONTINUED) MR16 2-Pin GU5.3 35 20859 Q35MR16C/CG40 12 20 C-6 23252 FAM6Q35MR16SPCCG 12 1 C-6 1.88 1.88 5000 5000 3000 3000 900 3200 2a, 2b, 4f, 9a, 10c 2a, 2b, 4f, 9a, 10c 1 C-6 1.88 5000 3000 900 2a, 2b, 4f, 9a, 10c 41487 Q35MR16/CCG40 50 20872 Q50MR16C/CG15 24 20 C-6 12 20 C-6 1.88 1.88 4000 6000 2950 3050 920 8400 2a, 2b, 4f, 9a, 10c 2a, 2b, 4f, 9a, 10c 20871 Q50MR16C/CG25 12 20 C-6 1.88 6000 3050 2900 2a, 2b, 4f, 9a, 10c 20867 Q50MR16C/CG40 20865 Q50MR16C/CG55 12 20 C-6 12 20 C-6 1.88 1.88 6000 6000 3050 3050 1500 850 2a, 2b, 4f, 9a, 10c 2a, 2b, 4f, 9a, 10c 23253 FAM6Q35MR16FLCCG 12 21458 FAM6Q50MR16NSCCG 12 1 C-6 1.88 6000 3050 9500 2a, 2b, 4f, 9a, 10c 21457 FAM6Q50MR16FLCCG 12 1 C-6 1.88 6000 3050 1720 2a, 2b, 4f, 9a, 10c 41488 Q50MR16/CCG15 41489 Q50MR16/CCG40 71 20876 Q71MR16C/CG15 24 20 C-6 24 20 C-6 12 20 C-6 1.88 1.88 1.88 4000 4000 4000 2950 8400 2950 1570 3050 10800 2a, 2b, 4f, 9a, 10c 2a, 2b, 4f, 9a, 10c 2a, 2b, 4f, 9a, 10c 20874 Q71MR16C/CG25 12 20 C-6 1.88 4000 3050 4550 2a, 2b, 4f, 9a, 10c 20873 Q71MR16C/CG40 12 20 C-6 1.88 4000 3050 2000 2a, 2b, 4f, 9a, 10c 12 20 CC-6 1.88 3000 2900 7400 20815 Q20MR16/C/NSP15 12 20 C-6 1.88 5000 2900 3750 20814 Q20MR16C/FL40 10 12 20 C-6 1.88 5000 2900 525 35 20826 Q35MR16/C/SP20 12 20 C-6 1.88 5000 3000 3900 20825 Q35MR16/C/FL40 12 20 C-6 1.88 5000 3000 1000 42 20830 Q42MR16/C/VNSP9 12 20 CC-6 1.88 3500 3000 12300 50 20839 Q50MR16/C/NSP15 12 20 C-6 1.88 6000 3050 9100 20835 Q50MR16/C/NFL25 12 20 C-6 1.88 6000 3050 3200 20834 Q50MR16C/NFL30 12 20 C-6 1.88 6000 3050 2500 20833 Q50MR16/C/FL40 12 20 C-6 1.88 6000 3050 1700 20832 Q50MR16/C/WFL55 12 20 C-6 1.88 6000 3050 900 71 20843 Q71MR16/C/NSP15 12 20 C-6 1.88 4000 3050 11500 20841 Q71MR16/C/NFL25 12 20 C-6 1.88 4000 3050 5500 20840 Q71MR16/C/FL40 12 20 C-6 1.88 4000 3050 2200 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c ® Flood, ANSI: FMW Spot, Carded ANSI: FRB Flood, Clear Glass Carded, ANSI: FMW Flood Narrow Spot ANSI: EXT Narrow Flood ANSI: EXZ Flood, ANSI: EXN Wide Flood, ANSI: FNV Narrow Spot. Carded, ANSI: EXT Flood. 3050K. Carded, ANSI: EXN Narrow Spot Flood Narrow Spot, ANSI: EYF Narrow Flood, ANSI: EYJ Flood, ANSI: EYC ™ CONSTANTCOLOR PRECISE MR16 MR16 2-Pin GX5.3 2-12 20 20816 Q20MR16/C/VNSP7 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Very Narrow Spot, ANSI: EZX Narrow Spot, ANSI: ESX Flood, ANSI: BAB Spot, ANSI: FRA Flood, ANSI: FMW Very Narrow Spot, ANSI: EZY Narrow Spot, ANSI: EXT Narrow Flood, ANSI: EXZ Narrow Flood, ANSI: EXK Flood, ANSI: EXN Wide Flood, ANSI: FNV Narrow Spot, ANSI: EYF Narrow Flood, ANSI: EYJ Flood, ANSI: EYC Halogen Lamps Bulb Shape Base Type Order Watts Code Description Rated Initial Case Filament Life Lumens Color Volts Qty. Type MOL LCL (hrs) Initial Temp. CBCP Footnotes Additional Information MR (CONTINUED) PRECISE™ COVER GLASS IR MR16 MR16 2-Pin GU5.3 37 16715 Q37MR16/HIR/CG10 16716 Q37MR16/HIR/CG25 16717 Q37MR16/HIR/CG40 50 16718 Q50MR16/HIR/CG10 16719 Q50MR16/HIR/CG25 16720 Q50MR16/HIR/CG40 12 12 12 12 12 12 20 25481 Q20MR16/SP 25480 Q20MR16/FL 20 C-8 20 C-8 20 C-8 20 C-8 20 C-8 20 C-8 1.8 1.8 1.8 1.8 1.8 1.8 4000 4000 4000 4000 4000 4000 3000 12500 3000 4400 3000 2050 3000 15000 3000 5700 3000 2600 2a, 2b, 4f, 9a, 10c 2a, 2b, 4f, 9a, 10c 2a, 2b, 4f, 9a, 10c 2a, 2b, 4f, 9a, 10c 2a, 2b, 4f, 9a, 10c Narrow Spot Narrow Flood Flood Narrow Spot Narrow Flood Flood 12 20 C-6 1.88 2000 2900 3500 Spot, ANSI: ESX 12 20 C-6 1.88 2000 2900 500 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2b, 4c, 4f, 9a, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, 9a, 9d, 10b, 10c STANDARD MR16 MR16 2-Pin GX5.3 81763 Q20MR16CGFLCD-BA 12 6 C-6 1.88 2000 81765 Q20MR16CGSPCD-BA 12 6 C-6 1.88 2000 35 81768 Q35MR16CGFLCD-BA 12 6 C-6 1.88 2000 81769 Q35MR16CGSPCD-BA 12 6 C-6 1.88 2000 50 81770 Q50MR16CGFLCD-BA 12 6 C-6 1.88 2000 81771 Q50MR16CGSPCD-BA 12 6 C-6 1.88 2000 25483 Q50MR16/SP 12 20 C-6 1.88 2000 2900 9500 25482 Q50MR16/FL 12 20 C-6 1.88 2000 2900 1500 2900 1500 42098 Q50MR16FL/CG/3PK 12 82110 Q50MR16FCCGRV-CD 12 6 C-6 6 C-6 1.88 1.88 2000 3000 82111 Q50MR16SCCGRV-CD 12 6 C-6 1.88 3000 12 10 C-6 1.38 3500 2900 1760 12 10 C-6 1.38 3500 2900 600 1 C-6 1.38 3500 2900 600 12 10 C-6 1.38 3500 2900 3000 12 10 C-6 1.38 3500 2900 1300 1.38 3500 2900 4100 Flood, ANSI: BAB Flood, Basic Spot, Basic Flood, Basic Spot, Basic Flood, Basic Spot, Basic Spot, ANSI: EXT Flood, ANSI: EXN Flood, ANSI: EXN Reveal®, Floodlight, Carded Reveal®, Spotlight, CardedMR (CONTI STANDARD MR11 MR11 2-Pin GZ4 20 30754 Q20MR11/SP15 41483 Q35MR11/CG12 24 24 50 C-6 1.38 2000 2950 4100 2a, 2b, 4e, 4c, 4f, 9a, 9d, 10b, 10c, 11a 2a, 2b, 4e, 4c, 4f, 9a, 9d, 10b, 10c, 11a 2a, 2b, 4e, 4c, 4f, 9a, 9d, 10b, 10c, 11a 2a, 2b, 4e, 4c, 4f, 9a, 9d, 10b, 10c, 11a 2a, 2b, 4e, 4c, 4f, 9a, 9d, 10b, 10c, 11a 2a, 2b, 4e, 4c, 4f, 9a, 9d, 10b, 10c, 11a 2a, 2b, 4c, 4f, 9a, 10c 41484 Q35MR11/CG30 24 24 50 C-6 1.38 2000 2950 1300 2a, 2b, 4c, 4f, 9a, 10c Narrow Flood 30773 Q20MR11/NFL30 25197 FAM6Q20MR11NF/CD 12 35 30774 Q35MR11SP20 30890 Q35MR11NFL30 25349 FAM6Q35MR11SP/CD 12 1 C-6 Spot, ANSI: FTC Narrow Flood, ANSI: FTD Narrow Flood, ANSI: FTD Spot, ANSI: FTF Narrow Flood, ANSI: FTH Spot, ANSI: FTF Spot 120V MR16 MR16 GU10 20 16753 Q20GU10/FL/CD 120 5 CC-2V 2.13 2000 2600 230 35 16752 Q35GU10/FL/CD 120 5 CC-2V 2.13 3000 2650 500 1a, 2a, 2b, 2e, 4f, 4i, 9a, 10b, 10c 1a, 2a, 2b, 2e, 4f, 4i, 9a, 10b, 10c For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 2-13 Halogen Lamps Bulb Shape Base Type Order Watts Code Description Rated Initial Case Filament Life Lumens Color Volts Qty. Type MOL LCL (hrs) Initial Temp. CBCP Footnotes Additional Information MR (CONTINUED) 120V MR16 (CONTINUED) MR16 GU10 50 16751 Q50GU10/FL/CD JDR16 Med 120 5 CC-2V 2.13 3000 82143 Q50GU10FL/RVL-CD 120 6 CC-2V 2.13 3000 3 CC-6V 2.05 3000 35 20641 35PAR16/CURIO 120 2750 2700 1000 1a, 2a, 2b, 2e, 4f, 4i, 9a, 10b, 10c 1a, 2a, 2b, 2e, 4f, 4i, 9a, 10b, 10c 1a, 2a, 2b, 2e, 4f, 4i, 9a, 10b, 10c 500 Reveal®, Floodlight, Carded QUARTZ HALOGEN T3 2-Pin G4 5 42959 Q5T3/CL 12 100 C-6 1.25 0.75 2000 60 10 34674 Q10T3/CL 12 100 C-6 1.25 0.75 2000 140 12 25 C-6 1.25 0.75 2000 140 12 100 C-6 1.25 0.75 2000 350 12 25 C-6 1.25 0.75 2000 350 240 19371 Q10T3/CL/CD 5PK 20 34715 Q20T2.5/12V/CL 19375 Q20T3/CL/CD 5PK T4 T3 2-Pin G8 25 16809 Q25G8/CD2 120 5 CC-2V 1.59 1.04 1500 35 48428 Q35G8/CD 120 5 CC-2V 1.77 1.34 1500 2-Pin GY6.35 35 34708 Q35T3/12V/CL 48503 Q35T3/CL/CD 5PK T4 2-Pin G8 50 21941 Q50G8/CD T3 2-Pin GY6.35 50 34702 Q50T3/12V/CL 12 100 C-6 1.75 2000 12 25 C-8 1.75 2000 5 CC-2V 1.77 1.34 1300 700 120 550 12 100 C-6 1.75 2000 900 19376 Q50T3/CL/CD 5PK 12 25 C-6 1.75 1.16 2000 900 T4 2-Pin GY6.35 75 19377 Q75T4/CL/CD 5PK 12 25 C-6 1.75 1.16 2000 1600 T4 2-Pin G8 T3 75 47801 Q75G8/CD 120 5 CC-2V 1.77 1.34 1500 100 47803 Q100G8/CD 120 5 CC-2V 1.77 1.34 1500 2a, 2j, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4c, 4e, 4f, 9a, 9d, 10b, 10c 1a, 2a, 2b, 2e, 4f, 4i, 9a, 10b, 10c 1a, 2a, 2b, 2e, 4f, 4i, 9a, 10b, 10c 2a, 2j, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4c, 4e, 4f, 9a, 9d, 10b, 10c 1a, 2a, 2b, 2e, 4f, 4i, 9a, 10b, 10c 2a, 2j, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4c, 4e, 4f, 9a, 9d, 10b, 10c 1a, 2a, 2b, 2e, 4f, 4i, 9a, 10b, 10c 1a, 2a, 2b, 2e, 4f, 4i, 9a, 10b, 10c 2a, 2j, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2a, 2j, 4c, 4e, 4f, 9a, 9d, 10b, 10c 2-Pin GY6.35 100 34676 Q100T3/12V/CL 12 100 CC-6 1.75 2000 2350 34663 Q100T3/24V/CL 24 100 CC-6 1.75 2000 2000 Clear Clear Clear, Carded Clear, Carded Twin Pack, Carded Carded Carded Carded Clear, Carded Clear, Carded Carded Carded QUARTZLINE® HIR™ T2 R7s 225 12282 Q225T2CL/ULTRACD 120 60 C-8 4.69 2.5 T2.5 R7s 350 12283 Q350T3CL/ULTRACD 120 60 C-8 4.69 2.25 2000 10000 3075 2-14 3000 5950 2965 13894 Q350T3/CL/HIR 120 6 C-8 4.69 2.25 2000 10000 3075 14311 Q350T3/CL/HIR 130 6 C-8 4.69 2.25 2000 9600 3000 2a, 2b, 4c, 4d, 4e, IR, Clear, Horizontal B 1a, 4f, 9a, 9d, 10b, 10c, 12b 2a, 2j, 2k, 4a, 4c, 4d, IR, Clear, Horizontal, B 1a, 4e, 4f, 4g, 8a, 9a, 9d, Carded B B 10b, 10c, 12b 1a, 2a, 2j, 2k, 4a, 4c, 4d, IR, Clear, Horizontal 4e, 4f, 4g, 8a, 9a, 9d, 10b, 10c, 12b 1a, 2a, 2j, 2k, 4a, 4c, 4d, IR, Clear, Horizontal 4e, 4f, 4g, 8a, 9a, 9d, 10b, 10c, 12b For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Halogen Lamps Bulb Shape Base Type Order Watts Code Description Rated Initial Case Filament Life Lumens Color Volts Qty. Type MOL LCL (hrs) Initial Temp. CBCP Footnotes Additional Information QUARTZLINE® (CONTINUED) HIR™ (CONTINUED) T2.5 R7s 900 13642 Q900T3/CL/HIR 240 6 C-8 10.06 6.13 2000 32000 3160 14335 Q900T3/CL/HIR 277 6 C-8 10.06 6.13 2000 31000 3160 1a, 2a, 2j, 2k, 4a, 4c, 4d, IR, Clear, Horizontal B 4e, 4f, 4g, 8a, 9a, 9d, 10b, 10c, 12b 1a, 2a, 2j, 2k, 4a, 4c, 4d, IR, Clear, Horizontal B 4e, 4f, 4g, 8a, 9a, 9d, Halogen 10b, 10c, 12b HALOGEN T4 G9 25 16754 Q25G9/CD 120 5 CC-8 1.77 1.26 3000 120 5 CC-8 1.77 1.26 3000 120 5 CC-8 1.77 1.26 2000 81301 Q40G9/F/CD 120 5 CC-8 1.77 1.26 2000 60 81468 Q60G9/F/CD 120 5 CC-8 1.77 1.26 3000 75 81469 Q75G9/F/CD 120 5 CC-8 1.77 1.26 3000 81300 Q25G9/F/CD 40 16755 Q40G9/CD T4 2-Pin PreFoc 45 41541 Q45T4/CL G9 T3 Mini-Cand 2.5 T3 1.26 3000 75 16759 Q75G9/CD 120 5 CC-8 1.77 1.26 3000 1100 2850 75 39574 Q75CL 28 20 CC-6 2.5 120 25 CC-8 2.5 100 22489 Q100T3/CL/CD 5PK 120 60 C-8 Mini-Cand 100 16452 Q100MC T4 R7s R7s 835 5 CC-8 1.77 R7s D C Bay 500 120 780 2800 1.19 2000 1350 1.25 1000 1050 2850 3.13 1.25 1500 1650 2950 120 6 CC-8 2.81 1.38 2000 1550 2950 15507 Q100CL/MC 120 6 CC-8 2.81 1.38 2000 1600 2950 44385 Q100CL/MC/2V 120 6 CC-2V 2.81 1.38 19383 Q100CL/MC/CD 5PK 120 25 CC-8 2.81 T4 1.53 480 2750 60 16756 Q60G9/CD 12715 Q75CL/MC/CD T4 12 C-6 240 2650 100 16451 Q100DC 750 1800 2950 1.38 2000 1600 2950 120 6 CC-8 2.44 1.38 2000 1550 2950 15508 Q100CL/DC 120 6 CC-8 2.44 1.38 2000 1600 2950 44386 Q100CL/DC/2V 120 6 CC-2V 2.44 1.38 150 27449 Q150T3/117/CL/CD 750 1800 2950 120 60 C-8 4.69 2.25 1500 2400 2950 19378 Q150T3/CL/CD 5PK 120 60 C-8 3.13 1.25 1500 2400 2950 80905 Q150T3/HD/CD2 3.13 1.25 2000 150 23710 Q150T4/CL 120 25 C-8 25 12 CC-8 2.56 2950 3000 2760 2850 1a, 2a, 2b, 2e, 4f, 4i, Carded 9a, 10b, 10c 1a, 2a, 2b, 2e, 4f, 4i, Frosted, Carded 9a, 10b, 10c 1a, 2a, 2b, 2e, 4f, 4i, Carded 9a, 10b, 10c 1a, 2a, 2b, 2e, 4f, 4i, Frosted, Carded 9a, 10b, 10c 1a, 2a, 2b, 2e, 4f, 4i, Frosted, Carded 9a, 10b, 10c 1a, 2a, 2b, 2e, 4f, 4i, Frosted, Carded 9a, 10b, 10c 2a, 2j, 4a, 4c, 4d, 4e, 4f, Clear, Airport, Base 4g, 8a, 9a, 9d, 10b, Down 10c, 12c 1a, 2a, 2b, 2e, 4f, 4i, Carded 9a, 10b, 10c 1a, 2a, 2b, 2e, 4f, 4i, Carded 9a, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, Clear 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear, Carded 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear, Horizontal, 4g, 9a, 9d, 10b, 10c, 11a Carded 1a, 2a, 2j, 4a, 4c, 4e, 4f, Frosted 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear, Carded 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Frosted 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4d, Clear, Horizontal, 4e, 4f, 4g, 9a, 9d, 10b, Carded 10c, 11a 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear, Horizontal, 4g, 9a, 9d, 10b, 10c, 11a Carded 1a, 2a, 2j, 4a, 4c, 4e, 4f, Carded, Heavy Duty 4g, 9a, 9d, 10b, 10c, 11a 2a, 2j, 4a, 4c, 4e, 4f, 4g, Clear, Dental Spotlight 8a, 9a, 9d, 10b, 10c For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 2-15 Halogen Lamps Bulb Shape Base Type Order Watts Code Description Rated Initial Case Filament Life Lumens Color Volts Qty. Type MOL LCL (hrs) Initial Temp. CBCP Footnotes Additional Information QUARTZLINE® (CONTINUED) HALOGEN (CONTINUED) T4 Mini-Cand 150 44654 Q150MC 120 6 CC-8 3 1.38 2000 2700 2950 120 6 CC-8 3 1.38 2000 2800 2950 19386 Q150CL/MC/CD 5PK 120 25 CC-8 3 1.38 2000 2800 2950 43694 Q150CL/MC D C Bay T4 150 44653 Q150DC 120 6 CC-8 2.5 1.38 2000 2700 2950 43693 Q150CL/DC 120 6 CC-8 2.5 1.38 2000 2800 2950 44384 Q150CL/DC/2V 120 6 CC-2V 2.44 1.38 1000 2800 2950 2-Pin PreFoc 200 40702 Q200T4/CL 2-Pin GZ9.5 235 11548 Q235T4/3 T2.5 T4 T4 T2.5 T4 2-16 R7s Mini-Cand D C Bay R7s R7s 250 22865 Q250T3/CL-6PK 12 CC-6 2.5 33 12 CC-6 2.63 1.53 500 4500 1.53 150 6000 120 144 C-8 3.13 1.25 1500 4000 2950 22121 Q250T3/CL/CD 5PK 120 60 C-8 3.25 1.13 1500 4000 2950 250 43695 Q250MC 120 6 CC-8 3.16 1.63 2000 4850 2950 43696 Q250MC 130 6 CC-8 3.16 1.63 2000 4850 2950 43699 Q250CL/MC 120 6 CC-8 3.16 1.63 2000 5000 2950 19387 Q250CL/MC/CD 5PK 120 25 CC-8 3.16 1.63 2000 5000 2950 43700 Q250CL/MC 130 6 CC-8 3.16 1.63 2000 5000 2950 250 43701 Q250DC 120 6 CC-8 3 1.63 2000 4850 2950 43702 Q250DC 130 6 CC-8 3 1.63 2000 4850 2950 43697 Q250CL/DC 120 6 CC-8 3 1.63 2000 5000 2950 43698 Q250CL/DC 130 6 CC-8 3 1.63 2000 5000 2950 300 15535 Q300T3/HD/2CD 120 5 C-8 4.68 2.25 2000 5950 2950 43704 Q300T3-6PK 120 144 C-8 4.69 2.25 2000 5900 2950 43703 Q300T3/CL-6PK 120 144 C-8 4.69 2.25 2000 5950 2950 19379 Q300T3/CL/CD 5PK 120 60 C-8 4.69 2.25 2000 5950 2950 27447 Q300T3CL/CD2-5PK 120 60 C-8 4.69 2.25 2000 5950 2950 120 12 CC-8 3.13 2.25 2000 5650 2900 300 43705 Q300T4/CL 1a, 2a, 2j, 4a, 4c, 4e, 4f, Frosted 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear, Carded 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Frosted 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear 4g, 8a, 9a, 9d, 10b, 10c, 12e 2a, 2j, 4a, 4c, 4d, 4e, Clear, Airport, 4f, 4g, 8a, 9a, 9d, 10b, Base Down 10c, 12c 2a, 2j, 4a, 4c, 4e, 4f, 4g, Frosted, Instrument, 8a, 9a, 9d, 10b, 10c Prefocus 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear, Horizontal 4g, 9a, 9d, 10b, 10c, 11a 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear, Carded 4g, 9a, 9d, 10b, 10c, 11a 1a, 2a, 2j, 4a, 4c, 4e, 4f, Frosted 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Frosted 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear, Carded 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Frosted 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Frosted 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4d, 4e, 4f, 4g, 9a, 9d, 10b, 10c, 11a 1a, 2a, 2j, 4a, 4c, 4d, 4e, Frosted, Horizontal 4f, 4g, 9a, 9d, 10b, 10c, 11a 1a, 2a, 2j, 4a, 4c, 4d, 4e,Clear, Horizontal 4f, 4g, 9a, 9d, 10b, 10c, 11a 1a, 2a, 2j, 4a, 4c, 4d, Clear, Horizontal, 4e, 4f, 4g, 9a, 9d, 10b, Carded 10c, 11a 1a, 2a, 2j, 4a, 4c, 4d, Clear, Horizontal, 4e, 4f, 4g, 9a, 9d, 10b, Carded 10c, 11a 1a, 2a, 2j, 4a, 4c,4e, 4f, Clear 4g, 9a, 9d, 10b, 10c, 11a For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Halogen Lamps Bulb Shape Base Type Order Watts Code Description Rated Initial Case Filament Life Lumens Color Volts Qty. Type MOL LCL (hrs) Initial Temp. CBCP Footnotes Additional Information QUARTZLINE® (CONTINUED) HALOGEN (CONTINUED) T4 T2.5 T4 Mini-Cand R7s D C Bay 400 43706 Q400MC 120 6 CC-8 3.62 2 2000 7850 2950 43707 Q400CL/MC 120 6 CC-8 3.62 2 2000 8250 2950 500 15537 Q500T3/HD/2CD 120 5 C-8 4.68 2.25 2000 11100 2950 23731 Q500T3/CL 120 12 C-8 4.69 2.25 2000 11100 3000 23733 Q500T3/CL 130 12 C-8 4.69 2.25 2000 10550 3000 23744 Q500T3/CL/6-12PK 120 144 C-8 4.69 2.25 1500 10950 3000 19382 Q500T3/CL/CD 5PK 120 60 C-8 4.69 2.25 2000 11100 3000 27448 Q500T3CL/CD2-5PK 120 60 C-8 4.69 2.25 2000 11100 3000 120 6 CC-8 3.44 2.13 2000 10100 2950 120 6 CC-8 3.44 2.13 2000 10450 2950 500 43709 Q500DC 43710 Q500CL/DC T8 Spec 1” Ribbon 500 39071 Q500T8/1CL 20 CC-8 4.25 2.5 500 13400 3200 PAR56 Mog End Pr 500 43494 Q500PAR56NSP 120 6 CC-6 5 4000 8000 2950 96000 43495 Q500PAR56MFL 120 6 CC-6 5 4000 8000 2950 43000 43496 Q500PAR56WFL 120 6 CC-6 5 4000 8000 2950 19000 T3 R7s 1000 43711 Q1000T3/CL-6PK 230 144 C-8 10.06 6.13 2000 21500 3050 43712 Q1000T3/CL-6PK 240 144 C-8 10.06 6.44 2000 21500 3050 T6 R7s 1000 23800 Q1000T6/CL 120 6 CC-8 5.63 1 2000 23400 3200 T20 Mog BiPost 1000 41734 Q1000T20BP 120 6 CC-8 9.5 4 3000 22400 3050 PAR64 ExMogEndPr 1000 43497 Q1000PAR64NSP 120 6 CC-6 6 4000 19400 3000 200000 43498 Q1000PAR64MFL 120 6 CC-6 6 4000 19400 3000 80000 43499 Q1000PAR64/WFL 120 6 CC-6 6 4000 19400 3000 33000 1a, 2a, 2j, 4a, 4c, 4e, 4f, Frosted 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 2k, 4a, 4c, 4d, 4e, 4f, 4g, 8a, 9a, 9d, 10b, 10c, 12b 1a, 2a, 2j, 2k, 4a, 4c, 4d, Clear, Horizontal 4e, 4f, 4g, 8a, 9a, 9d, 10b, 10c, 12b 1a, 2a, 2j, 2k, 4a, 4c, 4d, Clear, Horizontal 4e, 4f, 4g, 8a, 9a, 9d, 10b, 10c, 12b 1a, 2a, 2j, 2k, 4a, 4c, 4d, Clear, 6 Filament 4e, 4f, 4g, 8a, 9a, 9d,, Support, Rough 10b, 10c, 12b Service, Horizontal 1a, 2a, 2j, 2k, 4a, 4c, 4d, Clear, Horizontal, 4e, 4f, 4g, 8a, 9a, 9d, Carded 10b, 10c, 12b 1a, 2a, 2j, 2k, 4a, 4c, 4d, Clear, Horizontal, 4e, 4f, 4g, 8a, 9a, 9d, Carded 10b, 10c, 12b 1a, 2a, 2j, 4a, 4c, 4e, 4f, Frosted 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 4a, 4c, 4e, 4f, Clear 4g, 8a, 9a, 9d, 10b, 10c, 12e 1a, 2a, 2j, 2k, 4a, 4c, 4d, Clear, Airport, 4e, 4f, 4g, 8a, 9a, 9d, Special bulb 10b, 10c, 12b 1a, 2a, 2j, 4b, 4c, 4f, 4g, Narrow Spot 7a, 9b, 10c 1a, 2a, 2j, 4b, 4c, 4f, 4g, Medium Flood 7a, 9b, 10c 1a, 2a, 2j, 4b, 4c, 4f, 4g, Wide Flood 7a, 9b, 10c 1a, 2a, 2j, 2k, 4a, 4c, 4d, Clear, Horizontal 4e, 4f, 4g, 8a, 9a, 9d, 10b, 10c, 12b 1a, 2a, 2j, 2k, 4a, 4c, 4d, Clear, Horizontal 4e, 4f, 4g, 8a, 9a, 9d, 10b, 10c, 12b 1a, 2a, 2j, 4a, 4c, 4e, Clear 4f, 4g, 8a, 9a, 9d, 10b, 10c 12c Clear, Lighthouse, Base Down 1a, 2a, 2j, 4b, 4c, 4f, Narrow Spot 4g, 7a, 9b, 10c 1a, 2a, 2j, 4b, 4c, 4f, Medium Flood 4g, 7a, 9b, 10c 1a, 2a, 2j, 4b, 4c, 4f, Wide Flood 4g, 7a, 9b, 10c For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 2-17 Halogen Lamps Bulb Shape Base Type Order Watts Code Description Rated Initial Case Filament Life Lumens Color Volts Qty. Type MOL LCL (hrs) Initial Temp. CBCP Footnotes Additional Information QUARTZLINE® (CONTINUED) HALOGEN (CONTINUED) T3 R7s 1500 23828 Q1500T3/CL-12PK 208 144 C-8 10.06 6.25 2000 35800 3050 23826 Q1500T3/CL-12PK 220 144 C-8 10.06 6.81 2000 35800 3050 23830 Q1500T3/CL 240 12 C-8 10.06 6.31 2000 35800 3050 23832 Q1500T3/CL 277 12 C-8 6.25 2000 34400 3050 10.06 Wire Lead 6000 23843 Q6M/T3/CL/HT 480 12 C-8 11.94 9.75 100 Slv 480 12 C-8 11.94 9.75 150 6600 13511 QH6600T3/CL/HT 1a, 2a, 2j, 2k, 4a, 4c, 4d, Clear, Horizontal 4e, 4f, 4g, 8a, 9a, 9d, 10b, 10c, 12b 1a, 2a, 2j, 2k, 4a, 4c, 4d, Clear, Horizontal 4e, 4f, 4g, 8a, 9a, 9d, 10b, 10c, 12b 1a, 2a, 2j, 2k, 4a, 4c, 4d, Clear, Horizontal 4e, 4f, 4g, 8a, 9a, 9d, 10b, 10c, 12b 1a, 2a, 2j, 2k, 4a, 4c, 4d, Clear, Horizontal 4e, 4f, 4g, 8a, 9a, 9d, 10b, 10c, 12b 1a, 2a, 2b, 4c, 4d, 4e, 4f, Clear, Infrared, High 4g, 8a, 9a, 9d, 10b, Temp, Constr. 10c, 12b, 12e 1a, 2a, 2b, 4c, 4d, 4e, 4f,Clear, Infrared, 4g, 8a, 9a, 9d, 10b, Horizontal 10c, 12b, 12e 3250 AIRPORT T2.5 Special 45 23847 Q6 6A/T2 1/2/1CL T4 PK30d 100 80584 Q6.6A100PK30d-m 10 CBAR-6 2.0 0.79 1000 2700 T5 PK30d 100 80588 Q6.6A100PK30d-f 10 CBAR-6 2.0 0.79 1000 2700 T6 PK30d 150 80585 Q6.6A150PK30d-m 10 CBAR-6 2.0 0.79 1000 3600 T7 PK30d 150 80589 Q6.6A150PK30d-f 10 CBAR-6 2.0 0.79 1000 3600 T8 PK30d 200 80586 Q6.6A200PK30d-m 10 CC-6 2.3 0.79 1000 4800 T9 PK30d 200 80590 Q6.6A200PK30d-f 10 CC-6 2.3 0.79 1000 4800 T4 Spec 1” Ribbon D C Bay 200 23857 Q6.6A/T4/5CL 12 CC-8 3 200 23860 Q6.6AT4/DCR 12 CC-6 2.5 200 33279 Q6.6A PAR56/3 12 CC-6 4.5 1000 200000 PAR56 Mog End Pr 200 38271 Q6.6A/PAR56/2 12 CC-6 5 1000 16000 18309 Q6.6A/PAR56/4 12 CC-6 5 600 PAR56 Scrw Term PAR64 Mog End Pr 200 13224 Q6.6A/PAR 64/2P PAR56 Scrw Term 300 32861 Q20A/PAR56/2 Mog End Pr 300 15482 Q20A/PAR56/C PAR64 Mog End Pr 300 13223 Q6.6A/PAR 64/3P PAR56 Scrw Term 499 23863 Q20A/PAR56/3 Mog End Pr 500 15485 Q20A/PAR56/1/C 2-18 12 C-8 1.75 1000 710 500 5000 1.06 500 5150 6 CC-6 4.5 2000 12 CC-6 4.5 500 12 CC-6 5 500 6 CC-6 4.5 2000 12 CC-6 4.5 500 12 CC-6 5 500 200000 330000 2a, 2j, 4a, 4c, 4e, 4f, Clear, Airport 4g, 8a, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, Airport, Male Spade 4g, 8a, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, Airport, 4g, 8a, 9a, 9d, 10b, 10c Female Spade 2a, 2j, 4a, 4c, 4e, 4f, Airport, Male Spade 4g, 8a, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, Airport, 4g, 8a, 9a, 9d, 10b, 10c Female Spade 2a, 2j, 4a, 4c, 4e, 4f, Airport, Male Spade 4g, 8a, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, 4f, Airport, 4g, 8a, 9a, 9d, 10b, 10c Female Spade 2a, 2j, 4a, 4c, 4e, 4f, Clear, Airport 4g, 8a, 9a, 9d, 10b, 10c 2a, 2j, 4a, 4c, 4e, Clear, Airport, 4f, 4g, 8a, 9a, 9d, 10b, Ringed 10c, 12e 2a, 2j, 4b, 4c, 4d, 4f, 4g, PAR, Airport, BDTH 7a, 9b, 10c 2a, 2j, 4b, 4c, 4d, 4f, 4g, PAR, Airport, BDTH 7a, 9b, 10c 2a, 2j, 4b, 4c, 4d, 4f, 4g, PAR, Airport, 7a, 9b, 10c Prismatic Lens, BDTH 2a, 2j, 4b, 4c, 4d, 4f, 4g, PAR, Airport, BDTH 7a, 9b, 10c 2a, 2j, 4b, 4c, 4f, 4g, PAR, Airport, Burn 7a, 9b, 10c Position: Any 2a, 2j, 4c, 4f, 4g, 7a, PAR, Airport, 9b, 10c Teflon® Coated, Burn Position: Any 2a, 2j, 4b, 4c, 4d, 4f, PAR, Airport, BDTH 4g, 7a, 9b, 10c 2a, 2j, 4b, 4c, 4d, 4f, PAR, Airport, BDTH 4g, 7a, 9b, 10c 2a, 2j, 4c, 4f, 4g, 7a, PAR, Airport, 9b, 10c Teflon® Coated, Burn Position: Any For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Halogen Lamps Bulb Shape Base Type Order Watts Code Description Rated Initial Case Filament Life Lumens Color Volts Qty. Type MOL LCL (hrs) Initial Temp. CBCP Footnotes Additional Information TUBULAR QUARTZ HEAT T3 Slv R7s Slv 300 39019 QH300T3/CL 120 12 C-8 8.47 4.19 5000 2400 375 21337 QH375T3/CL 12 C-8 8.81 5.06 5000 2400 375 38893 QH375T3/CL/7 120 12 C-8 8.69 5.06 5000 2400 500 21787 QH500T3/CL/7 120 12 C-8 8.69 4.81 5000 2400 500 21788 QH500T3/CL 120 12 C-8 8.81 4.81 5000 2400 1000 22355 QH1000T3/CL 210 12 C-8 13.81 10 5000 2400 22357 QH1000T3/CL 240 12 C-8 13.81 10 5000 2400 22358 QH1000T3/CL/1 240 12 C-8 11.88 10 5000 2400 22365 QH1000T3/2CL/HT 240 12 C-8 13.81 10 5000 2400 1200 22531 QH1200T3/CL 144 12 C-8 8.81 6.13 5000 2450 144 12 C-8 8.81 6.13 5000 2450 1600 22686 QH1600T3/CL 210 12 C-8 19.81 15.88 5000 2350 22688 QH1600T3/CL 240 12 C-8 19.81 15.88 5000 2400 22695 QH1600T3/CL 277 12 C-8 19.81 15.88 5000 2400 1600 22691 QH1600T3/CL/7 240 12 C-8 19.63 15.88 5000 2400 22699 QH1600T3/CL/7 210 12 C-8 19.63 15.88 5000 2350 230 12 C-8 2450 22532 QH1200T3/CL/HT T3 R7s CER 2000 12716 QH2MT3/CL/HT/R Slv 2000 15551 QH2MT3/1CL/HT/VB 240 12 C-8 11.94 R7s 11.06 5000 500 2450 18668 QH2MT3/CL/VB 230 12 C-8 13.81 11.06 5000 2450 22789 QH2M/T3/1CL/HT 240 12 C-8 11.94 2450 22790 QH2M/T3/CL/HT 225 12 C-8 13.81 10 2500 22837 QH2500T3/CL/7 9.69 9.69 5000 5000 2450 460 12 C-8 28.63 24.88 5000 2400 1a, 2a, 2b, 3a, 4c, 4d, 4e, Infrared 4f, 4g, 9a, 9d, 10b, 10c, 12b, 12e 1a, 2a, 2b, 3a, 4c, 4d, 4e, Infrared 4f, 4g, 9a, 9d, 10b, 10c, 12b, 12e 1a, 2a, 2b, 3a, 4c, 4d, 4e, Infrared 4f, 4g, 9a, 9d, 10b, 10c, 12b, 12e 1a, 2a, 2b, 3a, 4c, 4d, 4e, Infrared 4f, 4g, 9a, 9d, 10b, 10c, 12b, 12e 1a, 2a, 2b, 3a, 4c, 4d, 4e, Infrared, Clear 4f, 4g, 9a, 9d, 10b, 10c, 12b, 12e 1a, 2a, 2b, 3a, 4c, 4d, 4e, Infrared 4f, 4g, 9a, 9d, 10b, 10c, 12b, 12e 1a, 2a, 2b, 3a, 4c, 4d, 4e, Infrared 4f, 4g, 9a, 9d, 10b, 10c, 12b, 12e 1a, 2a, 2b, 3a, 4c, 4d, 4e, Infrared, Clear, 4f, 4g, 9a, 9d, 10b, 10c, Horizontal 12b, 12e 1a, 2a, 2b, 3a, 4c, 4d, 4e,Infrared, Clear, High 4f, 4g, 9a, 9d, 10b, 10c, Temp, Constr., 12b, 12e Horizontal 1a, 2a, 2b, 3a, 4c, 4d, 4e, Infrared, Clear, 4f, 4g, 9a, 9d, 10b, 10c, Horizontal 12b, 12e 1a, 2a, 2b, 3a, 4c, 4d, 4e, Infrared, Clear, High 4f, 4g, 9a, 9d, 10b, 10c, Temp, Constr., 12b, 12e Horizontal 1a, 2a, 2b, 3a, 4c, 4d, 4e, Infrared, Horizontal 4f, 4g, 9a, 9d, 10b, 10c, 12b, 12e 1a, 2a, 2b, 3a, 4c, 4d, 4e, Infrared, Clear, 4f, 4g, 9a, 9d, 10b, 10c, Horizontal 12b, 12e 1a, 2a, 2b, 3a, 4c, 4d, 4e, Infrared, Horizontal 4f, 4g, 9a, 9d, 10b, 10c, 12b, 12e 1a, 2a, 2b, 3a, 4c, 4d, 4e, Infrared, Horizontal 4f, 4g, 9a, 9d, 10b, 10c, 12b, 12e 1a, 2a, 2b, 3a, 4c, 4d, 4e, Infrared, Horizontal 4f, 4g, 9a, 9d, 10b, 10c, 12b, 12e 1a, 2a, 2b, 3a, 4c, 4d, 4e, Infrared, Clear, High 4f, 4g, 9a, 9d, 10b, 10c, Temp, Horizontal, 12b, 12e Reflector 170° 1a, 2a, 2b, 3a, 4c, 4d, Infrared, Clear, High 4e, 4f, 4g, 9a, 9d, 10b, Temp, Constr., 10c, 12e Universal 1a, 2a, 2b, 3a, 4c, 4d, 4e, Infrared, Clear, 4f, 4g, 9a, 9d, 10b, 10c, Universal 12b, 12e 1a, 2a, 2b, 3a, 4c, 4d, 4e, Infrared, Clear, High 4f, 4g, 9a, 9d, 10b, 10c, Temp, Constr. 12b, 12e 1a, 2a, 2b, 3a, 4c, 4d, 4e,Infrared, Clear, High 4f, 4g, 9a, 9d, 10b, 10c, Temp, Constr., 12b, 12e Horizontal 1a, 2a, 2b, 3a, 4c, 4d, 4e, Infrared, Clear, 4f, 4g, 9a, 9d, 10b, 10c, Horizontal 12b, 12e For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 2-19 Halogen Lamps Bulb Shape Base Type Order Watts Code Description Rated Initial Case Filament Life Lumens Color Volts Qty. Type MOL LCL (hrs) Initial Temp. CBCP Footnotes Additional Information TUBULAR QUARTZ HEAT (CONTINUED) T3 Slv 2500 22838 QH2500T3/CL CER 2500 28126 QH2.5MT3/CL/HT/R 400 12 C-8 15.1 12.3 5000 2450 M4 Lug Term 2500 28129 QH2500T3/VB-10PK 240 10 C-8 13.8 11 5000 2450 CER 3000 28127 QH3MT3/CL/HT/R 400 12 C-8 15.1 12.3 5000 2450 M4 Lug Term 3000 28130 QH3MT3/VB-10PK 240 10 C-8 13.8 11 5000 2450 3650 10872 QH3650T3/CL/5 480 6 C-8 41.63 38 5000 2500 3800 22875 QH3800T3/CL 575 6 C-8 41.81 38 5000 2500 575 6 C-8 41.81 38 5000 2500 600 12 C-8 28.81 25.25 5000 2500 Slv 22878 QH3800T3/CL/VB 5000 22900 QH5M/T3/1CL/HT M4 Lug Term 2-20 480 12 C-8 28.81 24.88 5000 6000 29889 QH6000T3/HT-ASM 480 12 C-8 14.2 11.4 Wire Lead 6000 23843 QH6MT3/CL/HT 480 12 C-8 11.94 9.75 100 M4 Lug Term 480 12 C-8 11.94 9.75 150 6600 13511 QH6600T3/CL/HT 2400 3250 1a, 2a, 2b, 3a, 4c, 4d, 4e,Infrared, Clear, 4f, 4g, 9a, 9d, 10b, 10c, Horizontal 12b, 12e 1a, 2a, 2b, 3a, 4c, 4d, 4e,Infrared, High Temp, 4f, 4g, 9a, 9d, 10b, 10c, Horizontal, 12b, 12e Reflector 170o 1a, 2a, 2b, 3a, 4c, 4d, 4e,Infrared, Clear, 4f, 4g, 9a, 9d, 10b, 10c, Universal 12b, 12e 1a, 2a, 2b, 3a, 4c, 4d, 4e,Infrared, High Temp, 4f, 4g, 9a, 9d, 10b, 10c, Horizontal, 12b, 12e Reflector 170o 1a, 2a, 2b, 3a, 4c, 4d, 4e,Infrared, Clear, 4f, 4g, 9a, 9d, 10b, 10c, Universal 12b, 12e 1a, 2a, 2b, 3a, 4f, 5a, 5b, Infrared, Horizontal 9a, 9d, 10c, 12b, 12e 1a, 2a, 2b, 3a, 4f, 5a, 5b, Infrared, Horizontal 9a, 9d, 10c, 12b, 12e 1a, 2a, 2b, 3a, 4f, 5a, 5b, Infrared, Clear, 9a, 9d, 10c, 12e Universal 1a, 2a, 2b, 3a, 4c, 4d, 4e,Infrared, Clear, High 4f, 4g, 9a, 9d, 10b, 10c, Temp, Constr., 12b, 12e Horizontal 1a, 2a, 2b, 4c, 4d, 4e, Infrared, Clear, 4f, 4g, 9a, 9d, 10b, 10c, Horizontal, 12b, 12e High Temp. 1a, 2a, 2b, 4c, 4d, 4e, Infrared, Clear, 4f, 4g, 9a, 9d, 10b, 10c, Horizontal, 12b, 12e High Temp. 1a, 2a, 2b, 4c, 4d, 4e, Infrared, Clear, 4f, 4g, 9a, 9d, 10b, 10c, Horizontal, 12b, 12e High Temp. For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Halogen Lamps GENERAL INFORMATION QUARTZ HEAT LAMPS HALOGEN LAMP OPERATING PRECAUTIONS GE standard quartz heat products are primarily pressurized halogen lamps. Many standard tungsten coil filaments have been converted to a deflection coil winding design that eliminates the need for filament supports through an integral coil/support construction. These changes will improve lamp life as well as keep the bulb wall cleaner during operation and throughout the life of the lamp. In general, halogen lamps are more efficient than ordinary incandescent lamps. HIR™ lamps are the most efficient halogen lamps we offer. For each application, check life, lumens, wattage, beam spread and lamp dimensions to determine proper bulb selection. GE has added a reflectorized heat lamp with a patented design that directs the infrared to a surface rather than in 360° angle. The lamps listed in this catalog are filled to high internal gas pressures to maximize lamp efficacy (lumens per watt). Some general cautions are given below. HIGH OPERATING TEMPERATURES Since operating temperatures are critical to the effective self-cleaning properties of halogen lamps, filament tube wall temperatures should not go below 482°F (250°C). Hot spots on the bulb wall itself can go as high as 1230°F (700°C) in normal operation. Substantial heat is generated in all halogen lamps, so equipment design should make allowance for the dissipation of excessive heat. Certain lamps and extremely confined fixtures may require additional ventilation or heat sinking to ensure proper operation of the halogen cycle and to prevent damage to the fixture. It is a good practice to test the lamp in the operating environment early in the design cycle to ensure adequate performance. Precautions must be taken in the selection of materials for lampholders, reflectors and lamp housings because the 1230°F (700°C) bulb wall temperature is greater than the kindling temperature of many materials. Lamp base temperatures should not exceed 662°F (350°C) because, above that point, lead wires may deteriorate and the basing cement loosen, causing premature lamp failure. HALOGEN CAUTION NOTICE – GENERAL Halogen lamps are constructed of a glass bulb with a pressurized internal filament tube that operates at high temperatures and could unexpectedly shatter. Should the outer bulb break, particles of extremely hot glass could be discharged into the fixture enclosure and/or surrounding environment, thereby creating a risk of personal injury or fire. DISTRIBUTION OF SPECTRAL RADIATION Halogen lamps offer large amounts of visible and infrared energy from a small light source, with about 90% of the energy in the infrared. Some halogen lamps can be used for special applications where small amounts of ultraviolet energy are required. The slight ultraviolet radiation that comes from unprotected sources could cause skin and eye irritation following extended direct exposure. Passing the light through ordinary glass or plastic provides adequate protection. The lenses of the PAR, TAL or Cover Glass Precise™ lamps provide this protection. OPERATING NOTES HALOGEN A-LINE (TB/H) • Turn power off and let lamp cool before removal to avoid potential burn and electrical shock during lamp replacement • Do not use lamp if outer glass is scratched or broken because it may break during installation or later during operation • Do not use lamp in close proximity to combustible materials or those adversely affected by drying or fading action because of heat radiation in the lamp beam • Dispose of removed lamp with care such as placing in used lamp carton or other closed container Caution: Cracked or broken bulbs that still light should be replaced immediately. The inner tube of the GE Halogen lamp is pressurized, operates at high temperature and could unexpectedly shatter with the possibility of property damage or personal injury. Avoid use in unstable table lamps, dispose of with care. To avoid burns, electricity should be switched off and the lamp allowed to cool for several minutes before removing from socket. Use outdoors only in enclosed fixtures or where protected from exposure to water. OPERATING NOTES – LOW VOLTAGE LAMPS COMPACT PAR LAMPS (PAR20/30) Low voltage tungsten-halogen lamps are sensitive to voltage variations. Even a small change in voltage can have a considerable impact on lamp life. Designers should match fixture transformer ratings to actual line voltages to ensure that the lamps operate at as close to 12 volts as possible. Rapid cycling can also shorten lamp life, and designers should take advice from their GE Lighting representative before using these lamps in flashing or blinking applications. The lamps may be dimmed by reducing voltage. However, this may cause the bulbs to blacken. If this occurs the lamp should be run at full voltage for fifteen minutes, thereby clearing the problem. Note that the nature of low voltage lighting systems requires the use of fluorescent-type dimmers. Lamp can be operated on AC or DC currents. • Use outdoors in enclosed fixtures or where protected from exposure to water QUARTZLINE® PAR (250W) • Avoid use where subjected to exposure to moisture which may cause lamp to break or shatter • Do not operate lamp over 110% rated voltage. Overvoltage operation increases pressure and tendency to break. • Use this lamp only in fixtures designed for Q250PAR38 lamps For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 2-21 Halogen Lamps WARNINGS AND CAUTION NOTICES 1 6 WARNING Risk of electric shock a Turn power off before inspection, installation or removal b Turn power off if glass bulb is broken, even if bulb continures to light. Remove and dispose of lamp. c Do not open. No user serviceable parts inside. WARNING Risk of burn a Do not touch operating lamp 7 WARNING A damaged lamp emits UV radiation which may cause eye/skin injury a Turn power off if glass bulb is broken. Remove and dispose of lamp. 2 8 WARNING Risk of fire a Keep combustible materials away from lamp b Use in fixture rated for this product c Use in fixture rated for this product—see instructions d Operate base down to horizontal only e In table lamp use only with shade f Do not use in enclosed fixture or with lamp shade g Use in high intensity fixture rated for this product h Do not use as a night light i Burning position base down only j Use in enclosed fixture rated for this product k Fire Hazard! Do not use in Torchieres or other indoor residential fixtures WARNING Lamp emits UV radiation which may cause eye/skin injury. a Avoid exposure of eyes and skin to unshielded lamp 9 CAUTION Risk of burn a Allow lamp to cool before handling b Allow lamp/fixture to cool before handling c Do not touch operating lamp d Turn power off before installing lamp 10 WARNING Lamp emits IR radiation which may cause eye injury a Avoid exposure of eyes and skin to unshielded lamp CAUTION Lamp may shatter and cause injury if broken a Wear safety glasses and gloves when handling lamp b Dispose of lamp in a closed container c Do not use lamp if outer glass is scratched or broken 4 11 WARNING Pressurized lamp—unexpected rupture may cause injury, fire, or property damage a Use eye protection when handling lamp b Avoid direct water/liquid contact c Use in enclosed fixture rated for this product d Operate lamp only in specified position e Do not touch glass with bare hands f Do not use lamp if outer glass is scratched or broken g Do not exceed 110% of rated voltage h Do not use where directly exposed to water or outdoors without an enclosed fixture i Do not exceed rated voltage j Do not use lamp if outer jacket is scratched or broken, even if bulb continues to light. Turn power off, remove and dispose. k Do not use in wet locations CAUTION Lamp emits UV radiation which may cause eye/skin irritation. a Minimize exposure 3 12 OP. INST. a Burning Position - Base up b Burning position - horizontal c Burn base down only d Burn base down to horizontal e Limit seal temp to 650°F. Maintain min bulb wall temp of 500°F for operation of halogen cycle 5 WARNING Unexpected lamp rupture may cause injury, fire, or property damage a Do not touch glass with bare hands b Operate lamp only in specified position c Use in enclosed fixture rated for this product d Do not use lamp if outer glass is scratched or broken e Avoid direct water, liquid or metal contact 2-22 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Halogen Lamps HALOGEN LAMPS CROSS REFERENCE GE Description Osram/Sylvania Description GE Description Philips Description Osram/Sylvania Description Philips Description ORDER THIS IF YOU CURRENTLY USE GE LAMP THESE LAMPS HALOGEN PAR LAMPS ORDER THIS IF YOU CURRENTLY USE GE LAMP THESE LAMPS HALOGEN PAR LAMPS (CONTINUED) 60PAR16/H/SP10 60PAR16/H/FL30 75PAR16/H/SP10 75PAR16/H/FL30 Q21EMR16/C/SP12 Q21EMR16/C/FL25 50PAR20/H/SP10 50PAR20/H/FL25 50PAR30/H/SP10 50PAR30/H/FL25 50PAR30/H/FL35 50PAR30L/H/SP10 50PAR30L/H/FL40 50PAR30L/H/WFL 60PAR30/H/NSP9 60PAR30/H/FL25 60PAR30/H/FL35 75PAR30/H/SP10 75PAR30/H/FL25 75PAR30/H/FL35 75PAR30L/H/SP10 75PAR30L/H/FL25 75PAR30L/H/WFL 35PAR36/H/SP5 35PAR36/H/SP8 35PAR36/H/FL30 35PAR36/H/WFL 50PAR36/H/SP5 50PAR36/H/SP8 50PAR36/H/FL30 45PAR/H/SP10 45PAR/H/FL25 50PAR/H/SP10 50PAR/H/FL25 53PAR/H/SS/SP10 53PAR/H/SS/FL25 60PAR/H/SP10 60PAR/H/FL25 66PAR/H/SS/SP10 66PAR/H/SS/FL25 75PAR/H/NSP9 75PAR/H/FL25 79PAR/H/SS/SP10 79PAR/H/SS/FL25 90PAR/H/SP10 90PAR/H/FL25 90PAR/H/WFL 100PAR/H/SP10 100PAR/H/FL25 120PAR/H/SP9 120PAR/H/FL30 Q250PAR/SP10 Q250PAR/FL30 Q500PAR56NSP Q500PAR56MFL Q500PAR56WFL Q1000PAR64NSP Q1000PAR64MFL Q1000PAR64WFL 60PAR16/CAP/NSP10 60PAR16/CAP/NFL30 75PAR16/CAP/NSP10 75PAR16/CAP/NFL30 — — 50PAR20/CAP/SPL/NSP10 50PAR20/CAP/SPL/NFL30 50PAR30/CAP/SPL/NSP9 50PAR30/CAP/SPL/NFL25 50PAR30/CAP/SPL/FL40 50PAR30LN/CAP/SPL/NSP9 52PAR30LN/CAP/SPL/NFL30 50PAR30LN/CAP/SPL/WFL50 60PAR30/CAP/SPL/NSP9 60PAR30/CAP/SPL/NFL25 — 75PAR30/CAP/SPL/NSP9 75PAR30/CAP/SPL/NFL25 75PAR30/CAP/SPL/FL40 75PAR30LN/CAP/NSP9 75PAR30LN/CAP/NFL25 75PAR30LN/CAP/WFL40 36PAR36/CAP/VNSP5 36PAR36/CAP/NSP13 36PAR36/CAP/FL32 — 50PAR36/CAP/NSP6 — — 45PAR/CAP/SPL/SP9 45PAR/CAP/SPL/FL30 — — — — 60PAR/CAP/SPL/SP10 60PAR/CAP/SPL/NSL25 — — 75PAR/CAP/SPLSP9 75PAR/CAP/SPL/FL30 — — 90PAR/CAP/SPL/SP9 90PAR/CAP/SPL/FL30 60PAR16/HAL/NSP10 60PAR16/HAL/NFL27 — — — — 50PAR20/HAL/NSP9 50PAR20/HAL/NFL30 50PAR30S/HAL/NSP10 50PAR30S/HAL/NFL30 50PAR30S/HAL/FL40 50PAR30L/HAL/NSP9 50PAR30L/HAL/NFL30 50PAR30L/HAL/WFL60 60PAR30S/HAL/NSP10 60PAR30S/HAL/NFL30 60PAR30S/HAL/NFL40 75PAR30S/HAL/NSP10 75PAR30S/HAL/NFL30 75PAR30S/HAL/FL40 75PAR30L/HAL/NSP9 75PAR30L/HAL/NFL30 75PAR30L/HAL/FL40 — — — — — — — 45PAR38/HAL/SP12/LL 45PAR38/HAL/FL28/LL — — — — 60PAR38/HAL/NSP10/WLL 60PAR38/HAL/FL28/WLL — — 75PAR38/HAL/SP10/WLL 75PAR38/HAL/FL28/WLL — — 90PAR38/HAL/SP12/LL 90PAR38/HAL/FL28/LL 90PAR/CAP/SPL/WFL50 — — 120PAR/CAP/SPL/SP10 120PAR/CAP/SPL/FL30 250PAR/CAP/SPL/SP10 250PAR/CAP/SPL/FL30 500PAR56QNSP 500PAR56QMFL 500PAR56QWFL 1000PAR64QNSP 1000PAR64QMFL 1000PAR64QWFL 90PAR38/HAL/WFL60/WLL — — — — — — 500PAR56Q/NSP 500PAR56Q/MFL 500PAR56Q/WFL 1000PAR64Q/NSP 1000PAR64Q/MFL 1000PAR64Q/WFL HALOGEN HIR™ PAR LAMPS 45PAR30/HIR/SP9XL 45PAR30/HIR/FL25XL 45PAR30/HIR/FL35XL 50PAR30/HIR/SP9 50PAR30/HIR/FL25 50PAR30/HIR/FL35 45PAR/HIR/R/SP10 45PAR/HIR/R/FL25 45PAR/HIR/SP12XL 45PAR/HIR/FL40XL 50PAR/HIR/SP6 50PAR/HIR/SP9 50PAR/HIR/FL25 50PAR/HIR/S/SP10 50PAR/HIR/S/FL25 55PAR/HIR/R/SP10 55PAR/HIR/R/FL25 55PAR/HIR/SP12XL 55PAR/HIR/FL40XL 60PAR/HIR/SP10 60PAR/HIR/FL30 60PAR/HIR/FL40 60PAR/HIR/WFL 60PAR/HIR/S/SP10 60PAR/HIR/S/FL25 70PAR/HIR/SP10 70PAR/HIR/FL25 80PAR/HIR/SP10 80PAR/HIR/SP12 80PAR/HIR/FL25 90PAR/HIR/R/SP10 90PAR/HIR/R/FL25 — — — 50PAR30/CAP/IR/NSP9 50PAR30/CAP/IR/NFL25 50PAR30/CAP/IR/FL40 — — — — — 50PAR/CAP/IR/NSP9 50PAR/CAP/IR/NFL25 — — — — — — 60PAR/CAP/IR/SP9 60PAR/CAP/IR/FL30 — — — — — — 80PAR/CAP/IR/SP10 80PAR/CAP/IR/SP12 80PAR/CAP/IR/FL25 — — For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B — — — 50PAR30S/IRC/NSP10 50PAR30S/IRC/NFL30 50PAR30S/IRC/FL40 — — — — — 50PAR38/IRC/SP12 50PAR38/IRC/FL25 — — — — — — 60PAR38/IRC/SP12 60PAR38/IRC/FL25 — 60PAR38/IRC/WFL — — — — — — — — — 2-23 Halogen Lamps HALOGEN LAMPS CROSS REFERENCE GE Description Osram/Sylvania Description Philips Description GE Description ORDER THIS IF YOU CURRENTLY USE GE LAMP THESE LAMPS HALOGEN HIR™ PAR LAMPS (CONTINUED) 90PAR/HIR/SP12XL 90PAR/HIR/FL40XL 100PAR/HIR/SP10 100PAR/HIR/FL25 100PAR/HIR/FL40 — — 100PAR/CAP/IR/SP10 100PAR/CAP/IR/NFL25 100PAR/CAP/IR/FL40 20MR11/SP10/FTB 20MR11/FL35/FTD 35MR11/SP10/FTE 35MR11/FL40/FTH — — 100PAR38/IRC/SP10 100PAR38/IRC/FL25 100PAR38/IRC/WFL Q5T3/CL Q10T3/CL Q20T3/CL Q35T3/CL Q50T4/CL Q75T4/CL 20MRC11/SP10 20MRC11/FL30 — — 20MR16/NSP8/ESX 20MR16/FL40/BAB 50MR16/NSP12/EST 20MR16/FL40/EXN Q100CL/DC Q100CL/MC Q100DC Q150CL/DC/2V Q150CL/DC Q150CL/MC Q150CL/MC/2V Q150DC Q150MC Q250CL/DC Q250CL/MC Q250DC Q250MC 20MRC16/SP10 20MRC16/FL36 50MRC16/SP10 50MRC16/FL38 HALOGEN CONSTANTCOLOR® PRECISE™ MR16 LAMPS Q20MR16/C/VNSP7 Q20MR16/C/NSP15 Q20MR16/C/FL40 Q35MR16/C/SP20 Q35MR16/C/FL40 Q42MR16/C/VNSP9 Q50MR16/C/NSP15 Q50MR16/C/NFL25 Q50MR16/C/NFL30 Q50MR16/C/FL40 Q71MR16/C/NSP15 Q71MR16/C/NFL25 Q71MR16/C/FL40 20MR16/T/NSP/10 — 20MR16/T/NFL40 35MR16/T/NFL25 35MR16/T/FL40 50MR16/T/NSP10 — 50MR16/T/NFL25 — 50MR16/T/FL40 65MR16/T/NSP10 65MR16/T/NFL25 65MR16/T/FL40 5T3Q/CL 10T3Q/CL 20T3Q/CL/AX 35TQ/CL/AX 50T4Q/CL 75T4Q/CL/RP 20MRC16/CC/SP10 20MRC16/CC/NFL24 20MRC16/CC/FL38 — — — 50MRC16/CC/SP10 50MRC16/CC/NFL24 — 50MRC16/CC/NFL38 — — — 100Q/CL/DC 100Q/CL/MC 100Q/DC 150Q/CL/DC/1 150Q/CL/DC 150Q/CL/MC/2 150Q/CL/MC 150Q/DC 150Q/MC 250Q/CL/DC 250Q/CL/MC/2 250Q/DC 250Q/MC 2-24 37MR16/IR/NSP10C 37MR16/IR/NFL25C 37MR16/IR/FL40C 50MR16/IR/NSP10C 50MR16/IR/NFL25C 50MR16/IR/FL40C 100Q/CL/DC 100Q/CL — — 150Q/CL/DC 150Q/CL — 150Q/DC 150Q 250Q/CL/DC 250Q/CL — — HALOGEN DOUBLE-ENDED Q100T3/CL/CD Q150T3/CL Q300T3/CL Q500T3/CL 100T3Q/CL 150T3Q/CL 300T3Q/CL 500T3Q/CL HALOGEN HIR™ MR16 LAMPS Q37MR16/HIR/CG10 Q37MR16/HIR/CG25 Q37MR16/HIR/CG40 Q50MR16/HIR/CG10 Q50MR16/HIR/CG25 Q50MR16/HIR/CG40 5W12V/Capsule 10W12V/Capsule 20W12V/Capsule 35W12V/Capsule 50W12V/Capsule HALOGEN SINGLE-ENDED HALOGEN STANDARD MR16 LAMPS Q20MR16/SP Q20MR16/FL Q50MR16/SP Q50MR16/FL Philips Description ORDER THIS IF YOU CURRENTLY USE GE LAMP THESE LAMPS HALOGEN BIPIN LOW VOLTAGE HALOGEN MR11 LAMPS Q20MR11/SP15 Q20MR11/NFL30 Q35MR11/NSP20 Q35MR11/NFL30 Osram/Sylvania Description 35MRC16/IRC/SP8 35MRC16/IRC/NFL24 35MRC16/IRC/FL36 45MRC16/IRC/SP8 45MRC16/IRC/NFL24 45MRC16/IRC/FL36 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B BC100T3Q/CL/TP BC100T3Q/CL/TP 300T3Q/P/CL 500T3Q/P/CL High Intensity Discharge Lamps CONSTANTCOLOR® CMH® METAL HALIDE LAMPS MR16 ........................................................................................................................................... 3-9 PAR ............................................................................................................................................... 3-9 Elliptical ...................................................................................................................................... 3-9 Elliptical Open-Rated ........................................................................................................... 3-9 Single-Ended G12 ................................................................................................................3-10 Double-Ended TD ................................................................................................................3-10 GU6.5.........................................................................................................................................3-10 Mini’s..........................................................................................................................................3-10 High-Watt CMH® SPXX ....................................................................................................3-10 CMH® Chromafit™ ...............................................................................................................3-11 PULSEARC® MULTI-VAPOR® METAL HALIDE LAMPS ......3-11 MULTI-VAPOR® METAL HALIDE LAMPS .............................3-13 HIGH OUTPUT AND XHO MULTI-VAPOR® METAL HALIDE LAMPS .........................................................3-14 SPORTSLIGHTING .................................................................3-14 PROTECTED MULTI-VAPOR® METAL HALIDE LAMPS .......3-15 CHROMAFIT ™ MULTI-VAPOR® METAL HALIDE LAMPS (HPS RETROFIT LAMPS) ........................................................3-16 I-LINE MULTI-VAPOR® METAL HALIDE LAMPS (MERCURY RETROFIT LAMPS) .............................................3-16 SAF-T-GARD® SELF-EXTINGUISHING MULTI-VAPOR® LAMPS ........................................................3-16 ARCSTREAM® METAL HALIDE LAMPS ................................3-16 LUCALOX® HIGH PRESSURE SODIUM LAMPS ...................3-17 STANDBY LONGLIFE LUCALOX® LAMPS ............................3-18 ECOLUX® NC NON-CYCLING HIGH PRESSURE SODIUM LAMPS (TCLP COMPLIANT) ..................................3-18 ECOLUX® HIGH PRESSURE SODIUM LAMPS (TCLP COMPLIANT) ...............................................................3-19 SOX LOW PRESSURE SODIUM LAMPS................................3-20 MERCURY LAMPS ..................................................................3-20 SAF-T-GARD® MERCURY LAMPS ........................................3-21 E-Z MERC® SELF-BALLASTED LAMPS (INCANDESCENT RETROFIT) ...............................................3-21 EXPORT LAMPS Metal Halide ...........................................................................................................................3-21 Lucalox® High Pressure Sodium ...................................................................................3-22 E-Z Lux® Lucalox® High Pressure Sodium (Mercury Retrofit) ..........................3-22 Mercury ....................................................................................................................................3-22 HORTICULTURAL LAMPS .....................................................3-22 CROSS REFERENCE ...............................................................3-32 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 3-1 High Intensity Discharge Lamps BULB IDENTIFICATION DIA. DIA: Diameter of bulb at widest point. MOL: Maximum Overall Length including base or pins. LCL: Distance between the center of the arc tube and the Light Center Length reference plane. Note: Lamp drawings are not drawn to scale. Be sure to check size and dimension information when identifying each lamp. DIA. MOL LCL MOL To convert inches to millimeters, multiply the dimension (in inches) by 25.4 (i.e. 1.5’’ x 25.4 = 38.1 mm). LAMP LOCATOR MR16 GX10 ED17 Med T4 GU6.5 PAR20 Med PAR30L Med PAR38 Med BD17 Med PAR ED37 EX39 Elliptical T4.5 G12 ED28 EX39 T6 G12 T6, T7 Rx7s T4.5 BiPin G8.5 SingleEnded G12 Double-Ended TD Mini’s T15 Mog CMH® Chromafit™ Ceramic Metal Halide (HPS Retrofit Lamps) ConstantColor® CMH® Ceramic Metal Halide BD17 Med BT37 Mog ED17 Med ED23.5 Mog ED28 Mog ED37 Mog ED37 EX39 PulseArc® Multi-Vapor® Metal Halide Lamps 3-2 ED18 Mog ED28 Mog ED37 Mog Chromafit™ Multi-Vapor® Metal Halide Lamps (HPS Retrofit Lamps) For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B High Intensity Discharge Lamps BD17 Med BT37 Mog BT56 Mog ED28 Mog ED37 Mog Multi-Vapor® Metal Halide Lamps BT56 Mog ED37 Mog I-Line Multi-Vapor® Metal Halide Lamps (Mercury Retrofit Lamps) BT28 Mog BT37 Mog BT56 Mog ED28 Pos Mog ED37 Mog ED37 Mog ED37 Mog Saf-T-Gard® Self-Extinguishing Multi-Vapor® Lamps High Output and XHO Multi-Vapor® Metal Halide Lamps T9 #10 Spade T7 Rx7s BT56 Pos Mog BT56 Mog BT56 Mog PAR64 G38 ED17 Med ED28 EX39 ED37 EX39 Protected Multi-Vapor® Metal Halide Lamps Sportslighting For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 3-3 High Intensity Discharge Lamps CAP BiPin GY9.5 T6 R7s ED18 Mog T7 R7s T6 BiPin G12 ED18 Mog T15 Mog ED23 .5 Mog ED18 Mog Ecolux® NC Non-Cycling High Pressure Sodium Lamps (TCLP Compliant) Arcstream® Metal Halide Lamps ED23 .5 Mog Ecolux® High Pressure Sodium Lamps (TCLP Compliant) T7 Rx7s B17 Med ED18 Mog ED23 .5 Mog E25 Mog ED28 Mog ED37 Mog B17 Med T15 Mog B17 Med BT37 Mog BT56 Mog ED23 .5 Mog ED23 .5 Mog ED28 Mog ED37 Mog R40 Med R40 Mog R52 Mog Mercury Lamps 3-4 ED28 Mog Deluxe Lucalox® High Pressure Sodium Lamps Lucalox® High Pressure Sodium Lamps A23 .5 Med ED18 Mog For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B R60 Mog T16 Mog High Intensity Discharge Lamps BT37 Mog ED28 Mog T16 BY22d E-Z Lux® High Pressure Sodium Lamps (Mercury Retrofit) T21 BY22d SOX Low Pressure Sodium Lamps ED28 Mog ED37 Mog BT37 Mog Saf-T-Gard® Mercury Lamps ED24 Med ED28 Med ED28 Mog R57 Mog E-Z Merc® Self-Ballasted Lamps (Incandescent Retrofit) BASE IDENTIFICATION PG12 (Export Only) Med Screw E26 Recessed Single Contact R7s Export E27 2-Lug Sleeve BY22d Mog Screw E39 EX39 BiPin G8.5 GU6.5 PositionOriented Mogul GX10 Export E40 Admedium Skirted Med Skirt E26/50x39 BiPin G12 BiPin GY9.5 Mogul BiPost G38 Ext. Mog End Pr GX16d INTRODUCTION GE HID lamps provide the following benefits: High Efficacy/Low Operating Cost. HID is generally the most efficient light source. Better efficiency almost always means lower operating cost. Long Life. Most HID lamps have life ratings that are better than incandescent lamps and similar to fluorescent lamps. Compact Size. An HID lamp produces high light output from a relatively compact source. Like incandescent, it is a “point” light source, which allows for good optical control. The chart at right shows how HID lamps compare to incandescent, halogen, and fluorescent in terms of efficiency and rated life. Efficiency is measured in lumens per watt (LPW). Rated life for most lamp types is the number of burning hours when 50% of the tested samples have failed and 50% are still operational. For both HID and fluorescent, lamp life depends on the number of hours per start. The combination of high efficiency and long life makes HID an ideal light source for many commercial and industrial applications. Typical Lamp Characteristics Lamp Type Typical LPW Incandescent Rated Life (in hours) 5 - 22 750 - 2000 Halogen 12 - 36 2000 - 6000 Compact Fluorescent 27 - 80 9000 - 20,000 Fluorescent 75 - 100 12,000 - 24,000 + 50 - 60 12,000 - 24,000 + Mercury ConstantColor® CMH® 80 - 95 7,500 - 20,000 Multi-Vapor® Metal Halide 80 - 115 10,000 - 20,000 Lucalox® High Pressure Sodium 90 - 140 10,000 - 40,000 MVR/SP30: Same as MVR – warmer than MVR or MVR/C – matches SP30 fluorescent. MXR: Warm color (3200K) – good match for halogen. LU: Street lighting, parking areas, industrial, floodlighting, security, CCTV. LU/DX: Floodlighting, parking areas, indoor/outdoor pedestrian malls, industrial, security, roadway. Deluxe (DX) Mercury: Stores, public spaces – Metal Halide lamps however, are preferred. Clear Mercury: Landscape lighting, specialized floodlighting such as green copper roofs. SUGGESTED COLOR APPLICATIONS FOR HID LAMPS CMH®: Stores, people places, display, accent. MVR: Stores, public spaces, industrial, gymnasiums, floodlighting signs and buildings, parking areas, sports. MVR/C: Same as MVR – warmer color – diffuse coating reduces glare. For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 3-5 High Intensity Discharge Lamps PRODUCT INFORMATION GE CONSTANTCOLOR® CMH® CERAMIC METAL HALIDE LAMPS (pgs 3-9 to 3-11) • • • • • • GE MULTI-VAPOR® METAL HALIDE LAMPS (pgs 3-13 to 3-14) • Sparkling white light (3000-4000K) and very good color rendition (65-75 CRI) • Warm, rich 3000K color of SP30 blends well with incandescent, halogen and triphosphor fluorescent lamps for interior retail applications • High efficacy – more efficient than incandescent, mercury and most fluorescent sources • Long life – 10,000-20,000 hours for most types • Full line, 150-1000 watts, to meet most application needs • Uses: Downlighting, floodlighting, corridors, lobbies, walkways; retail, commercial, industrial Color uniformity lamp-to-lamp and over lamp life Excellent color rendering (80+ CRI, 90+ CRI for SPXX versions) Delivers more light than standard metal halide (10%–20% more) Lamp operates at high efficacy — up to 95 lumens per watt Many are universal burn — may be operated in any position Perfect for retail and commercial display lighting, accent and floodlighting, lobby and foyer lighting. Ideal for “people places.” GE CMH® CHROMAFIT ™ CERAMIC METAL HALIDE LAMPS (pg 3-11) GE HIGH OUTPUT MULTI-VAPOR® LAMPS (pgs 3-14) • Convert High Pressure Sodium sockets to crisp, white ceramic metal halide light (80+ CRI) • Operate on standard HPS ballasts and auxiliary equipment • Universal burn – may be operated in any position • Uses: Area lighting, industrial and “people places” • Enclosed glass fixtures only • More light – optimized for higher light output in horizontal, vertical base-up and base-down burn applications – Horizontal burn lamps provide up to 25% more light than standard universal burn equivalents – 400W vertical burn lamps provide up to 22% more light than standard universal burn equivalents; the highest lumen lamps available for operation on standard M59 ballasts • Longer life – horizontal burn lamps last up to 67% longer than universal burn lamp equivalents, significantly reducing replacement lamp and maintenance costs GE PULSEARC® MEDIUM BASED METAL HALIDE LAMPS (/MED MODELS) (pgs 3-11 to 3-13) • Low wattage metal halide lamps (formerly Halarc®) are now part of the PulseArc® family • Compact source • Sparkling white light (3000-4000K) and very good color rendition (70-75 CRI) • High efficacy – more than 3 times the lumens per watt of incandescent • Long life – up to 15 times longer than incandescent systems and up to 7 times longer than most PAR and R systems, saving maintenance and labor costs • Superior optical control • Uses: Display lighting, downlighting, floodlighting, corridors, lobbies, walkways; retail, office, commercial GE STAYBRIGHT® (/STB) LAMPS (pg 3-14) • Brighter longer – has 32% higher mean lumens while running on standard metal halide ballasts • Uses: Any application where fixed-orientation lamps can be used. Gas stations, sports lighting, billboards, retail, office, roadway, parking garages, floodlights, sign lighting. GE PROTECTED HIGH OUTPUT MULTI-VAPOR® LAMPS (/O) (pgs 3-14 to 3-16) • Protective quartz jacket surrounds the arc tube • The/O suffix and/or the “MPR” prefix in the Lamp Description indicates lamps are suitable for open fixture applications GE PULSEARC® MULTI-VAPOR® METAL HALIDE LAMPS (/PA MODELS) (pgs 3-11 to 3-13) GE CHROMAFIT ™ MULTI-VAPOR® LAMPS (/R) (pg 3-16) • Designed for operation only on approved ballasts with metal halide pulse ignitors • More light – 400W lamps provide highest initial and highest maintained lumens versus other standard universal or vertical base-up lamp options • 50% longer life – 400W lamps provide 30,000 hours life when burned on 120 hour on/1 hour off cycle (approximately continuous) • Faster hot restrike – less than 4 minutes versus 10-15 minutes for typical metal halide lamps 3-6 • Convert high pressure sodium sockets to crisp white metal halide light (65-70 CRI) • Operate on standard HPS ballasts and auxiliary equipment • Uses: Area lighting, industrial and “people places” GE I-LINE MULTI-VAPOR® LAMPS (pgs 3-16) • • • • Convert mercury sockets to crisp, white metal halide light More light, better color, energy cost savings for mercury users 40%-100% more light than existing mercury lamps Operate on standard CW and CWA mercury ballasts and auxiliary equipment For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B High Intensity Discharge Lamps PRODUCT INFORMATION (CONTINUED) GE SAF-T-GARD® MULTI-VAPOR LAMPS (MVT) (pg 3-16) • 6%-11% higher initial lumens than standard HPS in 100W and 400W versions • Long life - 30,000 hours • Open or enclosed fixtures • Uses: Industrial, roadway, security • Special self-extinguishing feature prevents exposure to UV in case outer bulb is punctured or broken; lamp turns off within 15 minutes • Meets requirements of Federal Standard 21CFR1040.30 • Saf-T-Gard® I-Line lamps convert mercury sockets to crisp, white metal halide light • Saf-T-Gard® I-Line lamps operate on standard mercury ballasts and auxiliary equipment • Uses: Industrial, commercial, gymnasiums, sports complexes, especially where open fixtures are used and risk of outer bulb breakage is possible GE ECOLUX® HIGH PRESSURE SODIUM LAMPS (/ECO) (pg 3-19) • Lead-free base. Passes TCLP, which can lower disposal costs. GE DELUXE LUCALOX® HIGH PRESSURE SODIUM LAMPS (pg 3-19) GE ARCSTREAM® METAL HALIDE LAMPS (pgs 3-16 to 3-17) • • • • • • Compact size, white light, excellent color • Precise optical control delivers a concentrated beam of light right where it’s needed • Variety of color temperatures (3,000K - 6,000K) • PAR64: ideal for long-range projection and sports lighting applications • Uses: Ideal for retail and commercial display lighting, floodlighting, accent/highlighting GE LUCALOX® High efficacy, lumen maintenance and long life of standard Lucalox® HPS High color rendering (65-70CRI), much better than standard HPS Blends well with incandescent and standard HPS sources Operates on standard HPS ballasts and auxiliary equipment Uses: Storage rooms, industrial facilities, offices, gymnasiums, malls, parks, building floodlighting GE E-Z LUX® HIGH PRESSURE SODIUM LAMPS (pg 3-19) • Direct replacement for mercury lamps on mercury ballasts • More efficient, 57-114% more lumens and 10-14% fewer watts than mercury lamps they replace • Uses: General lighting, roadway • See operating notes for further information HIGH PRESSURE SODIUM LAMPS (pgs 3-17 to 3-18) • • • • Very high efficacy/low operating cost Excellent lumen maintenance – over 90% @ 50% of life Very long life – 24,000+ hours Universal burn – can be operated in any position without affecting performance • Warm color • For open or enclosed fixtures • Uses: Industrial, roadway, security, floodlighting GE SOX LOW PRESSURE SODIUM LAMPS (pg 3-19 to 3-20) • Highest luminous efficacy for general, not for color-critical lighting • Monochromatic, yellow color (589nm) GE MERCURY LAMPS (pgs 3-20) • Long life and good efficacy • Phosphor coated Deluxe lamps provide good color rendering(50CRI) • Uses: Industrial, roadway, landscapes, residential and commercial security, parking lots GE DOUBLE-ENDED LUCALOX® LAMPS (/TD) (pg 3-18) • Compact tubular design fits compact fixtures for excellent optical control • High efficacy, lumen maintenance and long life of standard Lucalox® HPS GE SAF-T-GARD® MERCURY LAMPS (pg 3-21) • Special self-extinguishing feature prevents exposure to harmful UV in case outer bulb is punctured or broken; lamp turns off within 15 minutes • Meets requirements of Federal Standard 21 CFR 1040.30 • See operating notes for further information GE STANDBY LONGLIFE LUCALOX® LAMPS (/SBY) (pg 3-18) • Extra arc tube provides light instantly after momentary power interruption, and will increase to 80% light output in 1-2 minutes • Dual arc tubes provide 40,000 hour rated life • Operates on standard HPS ballasts and auxiliary equipment • Uses: Industrial, roadway, security, and hard-to-reach sockets GE E-Z MERC® SELF-BALLASTED MERCURY LAMPS (pg 3-21) • Retrofit incandescent sockets to longer-life mercury lamps without additional mercury ballasts or auxiliary equipment GE EXPORT BASE LAMPS (pg 3-21 and 3-22) GE ECOLUX® NC “NON-CYCLING” HIGH PRESSURE SODIUM LAMPS (/ECO/NC) (pgs 3-18 to 3-19) • Export-only lamps are not sold or intended for use in North America. The lamps are identified by “/27” or “/40” at the end of the lamp description, and comply with electrical characteristics defined by IEC standards. • Bulb shapes are generally similar to U.S. lamp types. Refer to drawings on pages 3-2 to 3-5. • Low mercury. Passes TCLP, which can lower disposal costs. • Non-cycling feature makes locating and replacing end-of-life lamps quick and easy • Lead-free base • High efficacy/low operating cost For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 3-7 High Intensity Discharge Lamps HID BRAND NAME CROSS-REFERENCE GE OSRAM/SYLVANIA Arcstream® MQI ChromaFit™ Multi-Vapor® ConstantColor® CMH® Ceramic Metal Halide Deluxe Lucalox® E-Z Lux® E-Z Merc® Ecolux® Ecolux® NC High Output Multi-Vapor® Horizontal Multi-Vapor® I-Line Multi-Vapor® Lucalox® Multi-Vapor® Protected High Output Multi-Vapor® PulseArc® Saf-T-Gard® Mercury Saf-T-Gard® Multi-Vapor® SOX Low Pressure Sodium Standby Longlife Lucalox® StayBright® Watt-Miser® Multi-Vapor® HEADINGS IN THIS CATALOG SECTION The following terms and descriptions can help you when checking High Intensity Discharge lamp specifications and when ordering products. Within each product line, lamps are divided into families. Within families, lamps are listed by wattage. In each of these wattage groups, lamps are listed by bulb shape. PHILIPS BRITE-LINE™, HQI® — Powerball MCP MHN-TD — MasterColor™ CDM — Unalux® — Lumalux ECO® Lumalux Plus™/ECO® Super Metalarc® Super Metalarc® — Lumalux® Metalarc® Metalarc® Pro-Tech™ Super Metalarc® Pulse Start Mercury Safeline® Metalarc® Safeline® SOX Low Pressure Sodium Lumalux® Standby — — Ceramalux™ Comfort Ceramalux™ Retrolux Self Ballasted Mercury Ceramalux Alto® Ceramalux Alto® Plus Metal Halide — — Ceramalux™ Metal Halide — Pulse Start Safety Lifeguard Mercury Safety Lifeguard Metal Halide SOX Low Pressure Sodium Instant Restrike Ceramalux™ — — ATTENTION: This brand-name cross-reference chart is provided only as a quick reference. Other lamp company brand listings may only represent a near equivalent, versus an identical match to GE Lighting brands. Individual lamp manufacturers’ performance specifications should be consulted. Lamp performance may be affected by environmental conditions, ballast type and/or other auxiliary equipment. Lumens - Mean: Bulb: Lamp light output (lumens) at 40% of rated lamp life for Metal Halide lamps and 50% of rated life for Mercury and HPS lamps. Bulb shape followed by its size (the maximum diameter of the bulb expressed in eighths of an inch). CBCP (Center Beam Candlepower): LET (Lamp Enclosure Type): Describes fixture requirements for this lamp (see page 3-22). LCL: Distance between the center of the filament and the Light Center Length reference plane, in inches. OP (Operating Position): (see page 3-23). MOL: Maximum Overall Length in inches. Base: The type of base. Bulb Base For reflector type lamps. Center Beam Candlepower is the intensity (candelas) at the center or maximum intensity of the beam. Used only for ConstantColor® CMH™ Metal Halide Lamps. Number of product units packed in a case. Lumens - Initial: Order Code: It is important to use this five-digit code when ordering to ensure that you receive the exact product you require. Initial light output. ANSI Ballast Type: Ballast type used to operate lamp. Rated Life Hours: The lamp‘s identification code. Description Color Rendering Index (CRI or Ra): An indication of the ability of the lamp to render object colors in a normal, natural way. The higher the number (0-100), the better the color appearance. Additional Information: Lamp burning hours to median life expectancy. Description: Order LET OP Watts MOL LCL Code Color Temperature Kelvins (K): A measure of the visual “warmth” or “coolness” of the light from the lamp. The higher the value the whiter or “cooler” the light appears. Case Qty.: Typical application and/or other important information. ANSI Rated Color Ballast Case Life Lumens Temp. Type Qty. CBCP (hours) Initial Mean K CRI Additional Information Footnotes Warning HIGH OUTPUT AND XHO MULTI-VAPOR® METAL HALIDE LAMPS 400 WATTS ED37 Mog S VBU 400 11.5 7 49656 MVR400/C/VBU M59 6 3-8 Identifies the lamp’s Outer bulb finish. wattage. Coated WHEN YOU DON’T KNOW THE LAMP DESCRIPTION MVR400 / C / VBU Identifies as Multi-Vapor® lamp. 20000 41000 26500 3700 70 1. Identify bulb shape by using illustrations on pages 3-2 to 3-5. 2. Measure bulb diameter using ruler in Appendix section page A-1 to determine width in eighths of an inch. 3. Identify base type using table on page 3-5. 4. Find your lamp in the tabular data containing the bulb shape, size and base, which are all listed by wattage. Operating position (see page 3-23) For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 121 High Intensity Discharge Lamps Bulb Base Order LET OP Watts MOL LCL Code Description ANSI Rated Color Ballast Case Life Lumens Temp. Type Qty. CBCP (hours) Initial Mean K CRI Additional Information Footnotes Warning CONSTANTCOLOR® CMH® METAL HALIDE LAMPS CMH® MR16 MR1620 GX10 T&L O U 20 2.28 85101 CMH20MR16/830/SP M156 85110 CMH20MR16/830/FL M156 97630 CMH20MR16/830/WFL M156 29485 CMH20PAR20/SP 29486 CMH20PAR20/FL 29487 CMH20PAR30/SP10 29488 CMH20PAR30/SP15 29489 CMH20PAR30/FL25 42068 CMH39/UPAR20/FL25 42069 CMH39/UPAR20/SP10 42066 CMH39/PAR30L/SP15 42067 CMH39/PAR30L/FL25 45066 CMH39/PAR30L/SP10 22152 CMH70/PAR30L/830SP 9000 9000 2900 9000 1500 9000 1000 1000 1000 3000 80 3000 80 3000 80 12 Spotlight, UV control 33, 51 25 Floodlight, UV control 33, 51 40 Wideflood, UV Control 33, 51 107 107 107 7500 7500 7500 7500 7500 10000 10000 10000 10000 10000 13000 1000 1000 1200 1200 1200 2100 2100 2400 2400 2400 4700 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 8 Spotlight, UV control 25 Floodlight, UV control 10 Spotlight, UV control 15 Spotlight, UV control 25 Floodlight, UV control 25 Floodlight, UV control 10 Spotlight, UV control 15 Spotlight, UV control 25 Floodlight, UV control 10 Spotlight, UV control 15 Spotlight, UV control 33, 51 33, 51 33, 51 33, 51 33, 51 33,45 33,45 33,45 33,45 33,45 33,45 107 107 107 107 107 107 107 107 107 107 107 13000 4700 3000 82 40 Floodlight, UV control 33,45 107 10000 4800 3000 82 15 Spotlight, UV control 33 108 10000 4800 3000 82 25 Spotlight, UV control 33 108 10000 4800 3000 82 Wide Floodlight, UV control 33 108 10000 6500 3000 81 15 Spotlight, UV control 33 108 10000 6500 3000 81 25 Spotlight, UV control 33 108 10000 6500 3000 81 Wide Floodlight, UV control 33 108 6 15000 6300 4100 3000 80 Clear 33 116 6 15000 6000 4000 3000 80 Coated 33 116 6 10000V 15000H 10000V 15000H 6600V 9200H 8700V 8700H 9200V 3000 83 6400H 6300V 3000 83 6300H Clear 33 116 Coated 33 116 15000 5700 4100 3000 80 Clear 33 116 15000 5700 4100 3000 80 Coated 33 116 15000 5500 4200 4000 90 Clear 33 116 15000 5200 4000 4000 90 Coated 33 116 12000 12900 9500 3000 80 Clear 33 116 CMH® PAR PAR20 Med O U 20 3.5 PAR30L Med O U 20 4.75 PAR20 Med O U 39 3.5 PAR30L Med O U 39 4.75 70 4.75 PAR38 Med O U 70 100 5.31 5.31 M156 15 13000 M156 15 3750 M156 6 19800 M156 6 14500 M156 6 4900 M130 15 7500 M130 15 22000 M130 6 29000 M130 6 11000 M130 6 39600 M98 or 6 43000 M139 22159 CMH70/PAR30L/830FL M98 or 6 10000 M139 45675 CMH70/PAR38/830SP15/ECO M98 or 6 40000 M139 45677 CMH70/PAR38/830FL25/ECO M98 or 6 14000 M139 45679 CMH70/PAR38/830WF/ECO M98 or 6 M139 45680 CMH100/PAR38/830S15/ECO M90 or 6 45000 M140 45681 CMH100/PAR38/830F25/ECO M90 or 6 15000 M140 45682 CMH100/PAR38/830W/ECO M90 or 6 M140 81 81 81 81 81 86 86 81 81 81 82 CMH® ELLIPTICAL BD17 Med E U 70 100 5.43 3.37 22119 CMH70/U/830/MED M98 or M139 22124 CMH70/C/U/830/MED M98 or M139 5.43 3.37 22127 CMH100/U/830/MED M90 or M140 22137 CMH100/C/U830/MED M90 or M140 6 CMH® ELLIPTICAL OPEN-RATED ED17 Med O U 70 150 3.37 31069 CMH70/U/830/MED/O M98 or 6 M143 31070 CMH70/C/U/830/MED/O M98 or 6 M143 31073 CMH70/U/942/MED/O M98 or 6 M143 31074 CMH70/C/U/942/MED/O M98 or 6 M143 3.37 31065 CMH150/U/830/MED/O M102 or 6 M142 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 3-9 High Intensity Discharge Lamps Bulb Base Order LET OP Watts MOL LCL Code Description ANSI Rated Color Ballast Case Life Lumens Temp. Type Qty. CBCP (hours) Initial Mean K CRI Additional Information Footnotes Warning CONSTANTCOLOR® CMH® METAL HALIDE LAMPS (CONTINUED) CMH® ELLIPTICAL OPEN-RATED (CONTINUED) ED17 Med O U 150 3.37 31066 CMH150/C/U830/MED/O M102 or 6 M142 31067 CMH150/U/942/MED/O M102 or 6 M142 31068 CMH150/C/U/942/MED/O M102 or 6 M142 12000 11900 8800 3000 80 Coated 33 15000 12000 9000 4200 90 Clear 33 15000 11000 8300 4200 90 Coated 33 M156 12 M130 12 M130 12 M85, 12 M98, or M139 M85, 12 M98, or M139 M81, 12 M102, or M142 M81, 12 M102, or M142 12000 10000 12000 15000 1600 3400 3150 6200 1060 2600 2700 4700 81 82 88 83 UV Control UV Control UV Control UV Control 33,39,51 39,44,45 39,44,45 39,44,45 15000 6000 4600 4200 93 UV Control 39,44,45 104 12000 14000 11000 3000 82 UV Control 39,44,45 104 12000 13000 11000 4200 94 UV Control 39,44,45 104 M85, 12 M98, or M139 92588 CMH70/TD/942/RX7S M85, 12 M98, or M139 5.37 2.62 92589 CMH150/TD/830/RX7S M81, 12 M102, or M142 92590 CMH150/TD/942/RX7S M81, 12 M102, or M142 15000 7000 5600 3000 81 UV Control 39,44 109 15000 7000 5600 4200 88 UV Control 39,44 109 15000 14000 11500 3000 80 UV Control 39,44 109 15000 14000 11500 4200 93 UV Control 39,44 109 CMH® SINGLE ENDED G12 T4.5 BiPin G12 E U 20 T6 BiPin G12 E U 70 3.56 2.18 29703 CMH20/T/U/830/G12 20153 CMH39/T/U/830/G12 29696 CMH39/T/U/942/G12 3.56 2.18 20016 CMH70/T/U/830/G12 20023 CMH70/T/U/942/G12 150 3.93 2.18 20017 CMH150/T/U/830/G12 20018 CMH150/T/U/942/G12 3000 3000 4200 3000 104 104 104 104 CMH® DOUBLE-ENDED TD T6 T7 Rx7s Rx7s E H45 70 E H45 150 4.5 2.25 92587 CMH70/TD/830/RX7S CMH® GU6.5 T4 GU6.5 CMH® T4.5 E U 20 2.05 1.18 85086 CMH20/TC/U/830/G6.5 M156 12 20 3.37 2 9000 1615 1100 3000 80 UV Control 33,44,51 104 12000 10000 12000 9000 1600 3400 3150 6200 1060 2600 2700 4700 81 82 88 83 UV Control UV Control UV Control UV Control 33,44,51 39,44,45 39,44,45 39,44,45 15000 6000 4600 4200 90 UV Control 39,44,45 104 20000 20000 20000 20000 20000 20000 20000 20000 23000 22000 30000 29000 34000 33000 40000 39000 MINI’S BiPin G8.5 E U 92696 CMH20/TC/U/830/G8.5 90352 CMH39/TC/U/830/G8.5 29698 CMH39/TC/U/942/G8.5 92585 CMH70/TC/U/830/G8.5 M156 12 M130 12 M130 12 M98 or 12 M139 29701 CMH70/TC/U/942/G8.5 M98 or 12 M139 3000 3000 4200 3000 104 104 104 104 HIGH-WATT CMH® SPXX ED28 EX39 O VBU 250 8.31 5 ED37 EX39 O VBU 320 11.31 7 350 11.31 7 400 11.31 7 3-10 48429 CMH250/VBU/PA/O 48432 CMH250/C/VBU/PA/O 17264 CMH320/PA/O 17267 CMH320/C/PA/O 11834 CMH350/VBU/940/PA/O 11835 CMH350/C/VBU/940/PA/O 49910 CMH400/VBU/940/PA/O 49911 CMH400/C/VBU/940/PA/O 12 12 6 6 6 6 6 6 18400 17600 24000 23200 27200 26400 32000 31200 4100 4100 3700 3700 3600 3600 3700 3700 90 90 90 90 90 90 92 92 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 33,45,52 106 33,45,52 106 33,45,52 106 33,45,52 106 33,45,52 106 33,45,52 106 33,45,49,52 106 33,45,49,52 106 High Intensity Discharge Lamps Bulb Base Order LET OP Watts MOL LCL Code Description ANSI Rated Color Ballast Case Life Lumens Temp. Type Qty. CBCP (hours) Initial Mean K CRI Additional Information Footnotes Warning CONSTANTCOLOR® CMH® METAL HALIDE LAMPS (CONTINUED) CMH® CHROMAFIT TM T15 ED18 Mog Mog E U E U 250 400 9.75 5.75 93357 CMH250/U/830/R 9.75 5.75 93295 CMH400/U/830/R S50 S51 12 12 16000 25000 20000 3000 85 20000 41000 31300 3000H 80> 3600V 44,45 105 44,45,49 105 PULSEARC® MULTI-VAPOR® METAL HALIDE LAMPS 32 WATTS ED17 Med O VBD 32 5.43 3.43 12651 MXR32/C/VBD/O 16469 MXR32/C/VBU/O M100 6 M100 6 10000 10000 2400 2400 1700 3200 70 1700 3200 70 Coated, protected Coated, protected 119 119 O U 50 5.43 3.43 45670 MXR50/U/MED/O 45671 MXR50/C/U/MED/O 10361 MXR50/U/MED 10364 MXR50/C/U/MED M110 M110 M110 M110 6 6 6 6 10000 10000 10000 10000 3400 3200 3200 3000 1700 1500 2100 2000 3500 3500 3700 3400 70 70 60 65 Clear, protected Coated, protected Clear Coated 119 119 118 118 O U 70 5.43 3.43 12377 MXR70/U/MED/O 12577 MXR70/C/U/MED/O 22158 MXR70/U/MED 22162 MXR70/C/U/MED 12590 MVR70/U/MED 12594 MVR70/C/U/MED M98 M98 M98 M98 M98 M98 6 6 6 6 6 6 15000 15000 12000 12000 12000 12000 5500 5300 5500 5300 4700 4500 3500 3300 3500 3300 3000 2800 3200 3200 3200 3200 4000 4000 70 70 70 70 75 75 Clear, protected Coated, protected Clear Coated Clear Coated 119 119 118 118 118 118 O U 100 5.43 3.43 12381 MXR100/U/MED/O 12579 MXR100/C/U/MED/O 18680 MXR100/U/MED 18679 MXR100/C/U/MED 12652 MVR100/U/MED 12653 MVR100/C/U/MED M90 M90 M90 M90 M90 M90 6 6 6 6 6 6 15000 15000 15000 15000 15000 15000 9000 8500 9000 8500 8100 7600 6200 5900 6200 5900 5800 4900 3200 3200 3200 3200 4000 4000 70 70 70 70 75 75 Clear, protected Coated, protected Clear Coated Clear Coated 119 119 118 118 118 118 O U 150 5.43 3.43 45683 MXR150/U/MED/O 45688 MXR150/C/U/MED/O 22935 MXR150/U/MED 22936 MXR150/C/U/MED 12598 MVR150/U/MED 12604 MVR150/C/U/MED M102 M102 M102 M102 M102 M102 6 6 6 6 6 6 15000 15000 15000 15000 15000 15000 12500 8600 3500 70 12000 8300 3500 70 13300 10000 3400 60 12600 9500 3100 60 14000 10500 4300 65 13300 10000 3900 70 Clear, protected Coated, protected Clear Coated Clear Coated 119 119 118 118 118 118 50 WATTS ED17 Med 70 WATTS ED17 Med 100 WATTS ED17 Med 150 WATTS ED17 Med 175 WATTS ED23.5 Mog BD17 Med E VBU 175 E VBU 175 7.5 5 22342 MXR175/VBU/PA M137 or 6 M152 11185 MXR175/C/VBU/PA M137 or 6 M152 12622 MVR175/VBU/PA M137 or 6 M152 12633 MVR175/C/VBU/PA M137 or 6 M152 5.75 3.43 12636 MVR175/VBU/MED/PA M137 or 6 M152 12637 MVR175/C/VBU/MED/PA M137 or 6 M152 15000 17000 12500 3200 65 Clear 43 117 15000 16000 12000 3200 65 Coated 43 117 15000 17500 13000 4000 75 Clear 43 117 15000 16500 12500 4000 75 Coated 43 117 15000 17500 13000 4000 75 Clear 43 117 15000 16500 12500 4000 75 Coated 43 117 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 3-11 High Intensity Discharge Lamps Bulb Base Order LET OP Watts MOL LCL Code Description ANSI Rated Color Ballast Case Life Lumens Temp. Type Qty. CBCP (hours) Initial Mean K CRI Additional Information Footnotes Warning PULSEARC® MULTI-VAPOR® METAL HALIDE LAMPS (CONTINUED) 250 WATTS ED28 Mog E VBU 250 8.25 5 26317 MVR250/VBU/PA 26319 MVR250/C/VBU/PA M138 or`12 M153 M138 or 12 M153 15000 23000 17000 4200 65 Clear 43 117 15000 21500 15500 3900 65 Coated 43 117 M132 or 12 M154 M132 or 12 M154 M132 or 12 M154 M132 or 12 M154 M132 or6 M154 M132 or 6 M154 M132 or 12 M154 20000 31000 18000 4000 65 Clear 43 117 20000 30000 16500 3700 70 Coated 43 117 20000 34000 25000 4000 65 Clear 43 116 20000 33000 23000 3700 70 Coated 43 116 20000 32000 22500 4000 65 Clear, protected 43 120 20000 30500 21500 3700 70 Coated, protected 43 120 20000 30600 24500 3700 70 Coated, protected 43 120 20000 20000 20000 20000 20000 Clear Coated Clear, protected Coated, protected Coated, protected 43 43 43 43 43 117 117 120 120 120 20000 41000 31000 4000 65 Clear 43, 49 121 20000 40000 30000 3700 70 Coated 43, 49 121 20000 44000 33000 4000 65 Clear 43, 49 121 20000 42000 31500 3700 70 Coated 43, 49 121 20000 42000 29500 4000 65 Clear, protected 43, 49 120 20000 40000 28000 3700 70 Coated, protected 43, 49 120 20000 44000 28500 4000 65 Clear 43, 49 120 20000 42000 27500 3700 70 Coated 43, 49 116 43, 49 116 320 WATTS ED28 Mog E VBU 320 8.25 5 27501 MVR320/VBU/HO/PA 27502 MVR320/C/VBU/HO/PA 45666 MVR320/VBU/XHO/PA 45669 MVR320/C/VBU/XHO/PA ED37 EX39 O VBU 320 11.5 7 46275 MPR320/VBU/XHO/PA 46276 MPR320/C/VBU/XHO/PA ED 28 EX39 O VBU 320 8.25 5 19609 MPR320/C/PA/ED28 350 WATTS ED37 Mog S V 350 11.5 7 40376 MVR350/VBUXHO/PA 40377 MVR350/CVBUXHOPA 10202 MPR350/VBU/PA 48824 MPR350/C/VBU/PA 48825 MPR350/C/VBU/3K/PA M131 M131 M131 M131 M131 6 6 6 6 6 45664 MVR400/VBU/HO/PA M135 or 6 M155 M135 or 6 M155 M135 or 6 M155 M135 or 6 M155 M135 or 6 M155 M135 or 6 M155 M135 or 12 M155 M135 or 12 M155 M135 or 6 M155 36500 34500 35200 33400 33400 27000 25000 24600 23500 23500 4000 3700 4000 4000 3400 62 65 65 70 70 400 WATTS ED37 Mog S VBU 400 11.5 7 45665 MVR400C/VBU/HO/PA 12642 MVR400/VBU/XHO/PA 12644 MVR400/C/VBU/XHO/PA ED37 EX39 O VBU 400 11.5 7 46273 MPR400/VBU/XHO/PA 46274 MPR400/C/VBUXHO/PA ED28 Mog E VBU 400 8.25 5 46271 MVR400/VBU/ED28/PA 46272 MVR400/C/VBU/ED28/PA ED37 3-12 Mog E V 400 11.5 7 46632 MVR400VBD/XHO/PA 20000 44000 35200 4000 65 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B High Intensity Discharge Lamps Bulb Base Order LET OP Watts MOL LCL Code Description ANSI Rated Color Ballast Case Life Lumens Temp. Type Qty. CBCP (hours) Initial Mean K CRI Additional Information Footnotes Warning PULSEARC® MULTI-VAPOR® METAL HALIDE LAMPS (CONTINUED) 750 WATTS BT37 Mog S VBU 750 11.5 7 27219 MVR750/VBU/PA 45560 MVR750/C/VBU/PA M149 6 M149 6 16000 82000 60000 4000 65 16000 72000 54000 3700 70 10389 MVR1000/U/BT37/PA M141 6 12000V 115000V 90000V 3900 65 9000H 105000H 82000H 13481 MVR150/U/WM M57 12 13490 MVR150/C/U/WM M57 12 7500H 13500V 10000V 11500H 7500H 12800V 10000V 10900H Clear Coated 43, 49 43, 49 121 121 Clear 43, 49 116 1000 WATTS BT37 Mog E U 1000 11.3 7 MULTI-VAPOR® METAL HALIDE LAMPS 150 WATTS ED28 Mog E U 150 8.25 5 8500V 4000 65 7200H 8000V 3700 70 6900H ® BClear, Watt-Miser &#174; BCoated, Watt-Miser &#174; ® 117 117 175 WATTS BD17 ED28 Med Mog PAR38 Med E U E U 175 175 5.75 3.43 18902 MVR175/U/MED 8.25 5 M57 6 26432 MVR175/U/MED/CP M57 4 19976 MVR175/C/U/MED M57 6 47760 MVR175/U M57 12 26433 MVR175/U/CP M57 47761 MVR175/C/U M57 12 17634 MVR175/SP30/U M57 12 4 E 175 5.62 25218 MVR175/PAR38/FL/1 M57 6 E U 250 8.25 5 42729 MVR250/U M58 12 175 8.25 5 26434 MVR250/U/CP M58 250 8.25 5 42731 MVR250/C/U M58 12 17633 MVR250/SP30/U M58 12 6000H 13600V 10000V 11700H 6000H 13600V 10000V 11700H 6000H 12900V 10000V 11900H 6000H 13600V 10000V 11700H 6000H 13600V 10000V 11700H 6000H 12900V 10000V 11900H 6000H 12000V 10000V 10300H 6500 7500V 12000V 8800V 7400H 8800V 7400H 8400V 7900H 8800V 7400H 8800V 7400H 8400V 7900H 7600V 6500H 7600V 4000 65 Clear 117 4000 65 Clear, Consumer Pack 117 3900 65 Coated 117 4000 65 Clear 117 4000 65 Clear, Consumer Pack 117 3900 70 Coated 117 3000 70 RE730 Phosphor Coating 117 3800 65 Clear, One-piece PAR 117 6000H 20800V 10000V 19100H 6000H 20800V 10000V 19100H 6000H 19800V 10000V 18200H 6000H 18000V 10000V 16600H 13500V 12400H 13500V 12400H 13000V 11600H 11500V 10600H 4200 65 Clear 117 4200 65 Clear, Consumer Pack 117 3900 70 Coated 117 3000 70 RE730 Phosphor Coating 117 250 WATTS ED28 Mog 4 360 WATTS ED37 Mog S VBU 360 11.5 7 13495 MVR360/VBU/WM/HO M59 13496 MVR360/C/VBU/WM/HO M59 6 6 43828 MVR400/U M59 6 26435 MVR400/U/CP M59 4 43829 MVR400/C/U M59 6 17632 MVR400/SP30/U M59 6 18904 MVR400/U/ED28 M59 12 19979 MVR400/C/U/ED28 M59 12 20000 36000 23500 4300 65 20000 35000 23000 4000 70 ® Watt-Miser &#174; 32, 49 BClear, Coated, Watt-Miser &#174; 32,49 B ® 121 121 400 WATTS ED37 ED28 Mog Mog S U E U 400 11.5 7 400 8.25 5 15000H 36000V 20000V 33100H 15000H 36000V 20000V 33100H 15000H 35000V 20000V 32200H 15000H 31000V 20000V 28500H 15000H 36000V 20000V 33100H 15000H 35000V 20000V 32200H 23500V 22100H 23500V 22100H 23000V 19300H 18600V 17100H 23500V 22100H 23000V 19300H 4000 65 Clear 49 121 4000 65 Clear, Consumer Pack 49 121 3700 70 Coated 49 121 3000 70 RE730 Phosphor Coating 49 121 4000 65 Clear, Compact Bulb 49 117 4000 65 Coated, Compact Bulb 49 117 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 3-13 High Intensity Discharge Lamps Bulb Base Order LET OP Watts MOL LCL Code Description ANSI Rated Color Ballast Case Life Lumens Temp. Type Qty. CBCP (hours) Initial Mean K CRI Additional Information Footnotes Warning MULTI-VAPOR® METAL HALIDE LAMPS (CONTINUED) 1000 WATTS BT56 BT37 Mog Mog S U E U 1000 15.37 9.5 41826 MVR1000/U 1000 11.5 7 M47 6 41827 MVR1000/C/U M47 6 18205 MVR1000/U/BT37 M47 6 11000H 108000V 15000V 100280H 11000H 105000V 15000V 96600H 9000H 115000V 12000V 105000H 86000V 4000 65 79000H 80000V 3700 65 73000H 90000V 3700 65 82000H Clear 49 121 Coated 49 121 Clear, Compact Bulb 49 121 HIGH OUTPUT AND XHO MULTI-VAPOR® METAL HALIDE LAMPS 175 WATTS ED28 PosMog E HOR 175 8.25 5 18104 MVR175/HOR M57 12 10000 15000 7700 4000 65 18105 MVR175/C/HOR M57 12 10000 14100 7500 3500 70 18101 MVR250/HOR M58 12 15000 21000 10000 4200 65 18103 MVR250/C/HOR M58 12 15000 19700 Clear, Position Oriented Socket Required Coated, Position Oriented Socket Required 117 117 250 WATTS ED28 PosMog E HOR 250 8.25 5 Clear, Position Oriented Socket Required Coated, Position Oriented Socket Required 9400 3600 70 117 117 360 WATTS - WATT-MISER® ENERGY-SAVING REPLACEMENT FOR 400W METAL HALIDE ED37 Mog S VBU 360 11.5 7 40053 MVR360/VBU/WM/XHO M59 40055 MVR360/C/VBU/WM/XHO M59 47685 MVR360/VBU/STB/WM M59 6 6 6 20000 37000 24000 4200 65 20000 35000 23000 4000 70 20000 36000 27000 4300 65 ® Watt-Miser &#174; 32,49 121 BClear, Coated, Watt-Miser &#174; 32,49 121 BClear, Watt-Miser &#174; 32,49 121 BStayBright &#174; 121 ® ® ® 47686 MVR360/C/VBU/STB/WM M59 6 20000 35000 26000 4000 70 ® Coated, Watt-Miser &#174; 32,49 121 BStayBright &#174; ® 400 WATTS ED37 ED28 BT28 BT37 Mog Mog Mog Mog S VBU 400 11.5 7 E VBU 400 8.31 7 E HOR 400 8.25 5 E HOR 400 11.5 7 26865 MVR400/VBU/STB/HO 26866 MVR400/CVBU/STB/HO 49657 MVR400/VBU/HO 49656 MVR400/C/VBU/HO 49655 MVR400/VBD 20931 MVR400/SP30/VBU/HO M59 M59 M59 M59 M59 M59 6 6 6 6 6 6 20000 20000 20000 20000 20000 20000 41000 41000 41000 41000 41000 34000 31000 29500 26500 26500 26500 20400 4000 3700 4000 3700 4000 3200 65 70 65 70 65 70 13923 MVR400/VBU/XHO 13924 MVR400/C/VBU/XHO 40335 MVR400/VBU/ED28/HO 40201 MVR400/HOR/BT28 26218 MVR400/HOR/MOG 26219 MVR400/C/HOR/MOG M59 6 M59 6 M59 12 M59 12 M59 6 M59 6 20000 20000 20000 20000 20000 20000 43000 42000 41000 37000 38000 36800 28000 27000 26500 22000 22500 22000 4000 3700 4000 4200 4200 3900 65 70 65 65 65 70 Clear, StayBright®&#174; 49 Coated, StayBright®&#174; 49 Clear 49 Coated 49 Clear 49 RE730 Phosphor Coating, 49 Vertical Base Up &#177;15& Clear 49 Coated 49 Clear, Compact Bulb 49 Clear, Compact Bulb 49 Clear 49 Coated 49 121 121 121 121 121 121 Clear, Protected Clear Coated 49 49 49 119 121 121 Clear, Narrow Spot, 6&#176; 38 Beam, 1,350,000 CBCP Clear, Narrow Spot, 6&#176; 38 Beam, 1,350,000 CBCP 124 121 121 121 117 117 117 1000 WATTS BT56 EX39 Mog O VBU 1000 15.37 9.5 41433 MPR1000/VBU/O S VBU 1000 15.37 9.5 44835 MVR1000/VBU/HO 13137 MVR1000/C/VBU/HO M47 M47 M47 6 6 6 12000 107000 85500 3500 65 15000V 111000V 87000V 3800 65 15000V 107000V 81500V 3700 70 29333 SPL1000/PAR64840 – 11350000 3500 63000 53000 4000 80 29336 SPL1000/PAR64/HR – 11350000 3500 63000 53000 4000 80 SPORTSLIGHTING 1000 WATTS PAR64 G38 3-14 E U 1000 6.87 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 124 High Intensity Discharge Lamps Bulb Base Order LET OP Watts MOL LCL Code Description ANSI Rated Color Ballast Case Life Lumens Temp. Type Qty. CBCP (hours) Initial Mean K CRI Additional Information Footnotes Warning SPORTSLIGHTING (CONTINUED) 1500 WATTS T7 BT56 Rx7s Mog E HOR 1500 10.12 5 16920 SPL1500/H/652 E U 1500 15.37 9.5 47326 MVR1500/U/SPORTS 37405 MVR1500/HBU – M48 1 6 M48 6 6000 120000 3000H 170000V 3000V 162000H 3000H 165000V 3000V 155000H 90000 5200 80 153000V 4000 65 133000H 140000V 3900 65 130000H Frosted Clear 38 125 17,42,49 117 Clear 16,17,49 117 1650 WATTS BT56 PosMog E HOR 1650 15.37 9.5 25532 MVR1650/HOR M112 6 3000 177000 145000 3200 65 Clear, Position Oriented 17,49 Socket Required 117 M134 10 3000 200000 170000 4000 65 Clear 125 2000 WATTS T9 #10 Spade E HOR 2000 10 4.3 12275 MQI2000/T9/40 PROTECTED 32 WATTS MULTI-VAPOR® ED17 O VBD 32 5.43 3.43 12651 MXR32/C/VBD/O 16469 MXR32/C/VBU/O M100 6 M100 6 10000 10000 2400 2400 1700 3200 70 1700 3200 70 Coated, protected Coated, protected 119 119 O U 50 5.43 3.43 45670 MXR50/U/MED/O 45671 MXR50/C/U/MED/O M110 6 M110 6 10000 10000 3400 3200 1700 3500 70 1500 3500 70 Clear, protected Coated, protected 119 119 O U 70 5.43 3.43 12377 MXR70/U/MED/O 12577 MXR70/C/U/MED/O M98 M98 6 6 12000 12000 5500 5300 3500 3200 70 3300 3200 70 Clear, protected Coated, protected 119 119 O U 100 5.43 3.43 12381 MXR100/U/MED/O 12579 MXR100/C/U/MED/O M90 M90 6 6 15000 15000 9000 8500 6200 3200 70 5900 3200 70 Clear, protected Coated, protected 119 119 O U 150 5.43 3.43 45683 MXR150/U/MED/O 45688 MXR150/C/U/MED/O M102 6 M102 6 15000 12500 15000 12000 8600 3500 70 8300 3500 70 Clear, protected Coated, protected 119 119 O VBU 175 8.25 5 49470 MPR175/VBU/O 11649 MPR175/C/VBU/O M57 M57 6 6 10000 14400 10200 4000 65 10000 12800 7800 3800 70 Clear, protected Coated, protected 119 119 O VBU 250 8.25 5 49471 MPR250/VBU/O 11650 MPR250/C/VBU/O M58 M58 6 6 10000 23000 17000 4000 65 10000 20500 14700 3800 70 Clear, protected Coated, protected 119 119 20000 32000 22500 4000 65 Clear, protected 120 20000 30500 21500 3700 70 Coated, protected 120 20000 30600 24500 3700 70 Coated, protected 43 120 20000 35200 28200 4000 65 20000 33400 26700 3700 70 20000 33400 26700 3200 70 Clear, protected Coated, protected Coated, protected 43 43 43 120 120 120 32,49 32,49 119 119 Med METAL HALIDE LAMPS 50 WATTS ED17 Med 70 WATTS ED17 Med 100 WATTS ED17 Med 150 WATTS ED17 Med 175 WATTS BT28 EX39 250 WATTS BT28 EX39 320 WATTS ED37 EX39 ED 28 EX39 O VBU 320 11.5 7 O VBU 320 8.25 5 46275 MPR320/VBU/XHO/PA M132 or 6 M154 46276 MPR320/C/VBU/XHO/PA M132 or 6 M154 19609 MPR320/C/PA/ED28 M132 or 12 M154 350 WATTS ED37 EX39 O VBU 350 11.5 7 10202 MPR350/VBU/PA M131 6 48824 MPR350/C/VBU/PA M131 6 48825 MPR350/C/VBU/3K/PA M131 6 360 WATTS - WATT-MISER® ENERGY-SAVING REPLACEMENT FOR 400W METAL HALIDE ED37 EX39 O VBU 360 11.5 7 40056 MPR360/VBU/WM/HO/O M59 11685 MPR360CVBUWMHO/O M59 6 6 20000 36000 23500 4000 65 20000 35000 22500 3700 70 protected BClear, Coated, protected For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 3-15 High Intensity Discharge Lamps Bulb Base Order LET OP Watts MOL LCL Code Description ANSI Rated Color Ballast Case Life Lumens Temp. Type Qty. CBCP (hours) Initial Mean K CRI Additional Information Footnotes Warning PROTECTED MULTI-VAPOR® METAL HALIDE LAMPS (CONTINUED) 400 WATTS ED37 EX39 O VBU 400 11.5 7 18708 MPR400/VBU/HO/O M59 6 13582 MPR400/C/VBU/HO/O M59 6 46273 MPR400/VBU/XHO/PA M135 or 6 M155 46274 MPR400/C/VBUXHO/PA M135 or 6 M155 20000 40000 26000 3800 65 20000 38000 25000 3600 70 20000 42000 29500 4000 65 Clear, protected Coated, protected Clear, protected 49 49 43,49 119 119 120 20000 40000 28000 3700 70 Coated, protected 43,49 120 12000 107000 85500 3500 65 Clear, Protected 49 119 Clear, HPS Retrofit Coated, HPS Retrofit 50 50 116 116 Clear, HPS Retrofit, Compact Bulb Clear, HPS Retrofit Coated, HPS Retrofit 49,50 116 49,50 49,50 122 122 1000 WATTS BT56 EX39 O VBU 1000 15.37 9.5 41433 MPR1000/VBU/O CHROMAFIT TM MULTI-VAPOR® M47 6 METAL HALIDE LAMPS (HPS RETROFIT LAMPS) 250 WATTS ED28 Mog E VBU 250 8.25 5.75 12762 MVR250/VBU/R 12769 MVR250/C/VBU/R S50 S50 12 12 8.31 5 10000 18500 13900 4500 65 10000 18000 13000 4000 70 400 WATTS ED28 Mog E U 400 26851 MVR400/U/ED28/R S51 12 ED37 Mog S VBU 400 11.5 5.75 12770 MVR400/VBU/R 12772 MVR400/C/VBU/R S51 S51 6 6 15000H 36000V 20000V 33100H 20000 37600 20000 35700 22000V 4000 65 20200H 22600 4500 65 21400 4000 70 I-LINE MULTI-VAPOR® METAL HALIDE LAMPS (MERCURY RETROFIT LAMPS) 325 WATTS ED37 Mog S U 325 11.5 7 10687 MVR325/I/U/WM H33 6 10688 MVR325/C/I/U/WM H33 6 43817 MVR400/I/U H33 or 6 M59 H33 or 6 M59 10000H 28000V 20000V 25800H 10000H 26300V 20000V 24200H 13300V 4000 65 Clear, Retrofit for 400W 12200H Mercury, Watt-Miser®&#174; 12900V 3700 70 ✐ Coated, Retrofit for 400W 11800H Mercury, Watt-Miser®&#174 10000H 36000V 15000V 33100H 10000H 35000V 15000V 32200H 24000V 4000 65 22100H 21000V 3700 70 19300H B 121 121 400 WATTS ED37 Mog S U 400 11.5 7 43818 MVR400/C/I/U Clear, Retrofit for 400W Mercury Coated, Retrofit for 400W Mercury 49 121 49 121 950 WATTS ENERGY-SAVING REPLACEMENT FOR 1000W MERCURY BT56 Mog S VBU 950 15.06 9.5 39097 MVR950/I/VBU SAF-T-GARD® SELF-EXTINGUISHING H36 or 6 M47 MULTI-VAPOR® 12000 100000 62900 3800 65 Coated, Retrofit for 49 121 B1000W Mercury, Watt-Miser &#17 ® LAMPS 400 WATTS ED37 Mog S U 400 11.5 7 11146 MVT400/I/U H33 or M59 11119 MVT400/C/I/U H33 or 6 M59 M59 6 M59 6 11144 MVT400/VBU 11145 MVT400/C/VBU 610000H 36000V 15000V 33100H 10000H 35000V 15000V 32200H 20000 41000 20000 41000 23500V 22100H 23000V 19300H 26500 26500 4000 65 3700 70 4000 65 3700 70 Clear, Retrofit for 400W Mercury Coated, Retrofit for49 400W Mercury Clear Coated 49 123 123 49 49 123 123 ARCSTREAM® METAL HALIDE LAMPS 70 WATTS T6 R7s E HOR 70 4.68 E HOR 150 5.37 34530 ARC70/TD/UVC/730 34536 ARC70/TD/UVC/743 M85 12 M85 12 6000 6000 M81 M81 M81 M81 M81 6000 6000 6000 6000 1000 6000 6000 4800 3000 75 4800 4300 75 Clear Clear 103 103 Clear Clear Clear Clear Clear, Disco Lamp 103 103 102 102 102 150 WATTS T7 R7s T6 BiPinG12 E U 150 CAP BiPinGY9.5 E U 150 3-16 34527 ARC150/TD/UVC/730 34535 ARC150/TD/UVC/742 3 2.25 21053 ARC150T/U/830G12 21054 ARC150T/U/840G12 1.62 1.12 34813 CSS150/CAP/50 12 12 10 10 10 13000 11000 3000 75 12000 10000 4200 75 12000 9500 3000 80 11500 10500 4000 80 10000 8000 5000 80 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B High Intensity Discharge Lamps Bulb Base Order LET OP Watts MOL LCL Code Description ANSI Rated Color Ballast Case Life Lumens Temp. Type Qty. CBCP (hours) Initial Mean K CRI Additional Information Footnotes Warning ARCSTREAM® METAL HALIDE LAMPS (CONTINUED) 250 WATTS T15 Mog E HOR 250 8.37 5.62 26683 ARC250/T/H/960/E M80 12 10000 19000 13300 6000 90 Clear, Daylight Color E HOR 400 10.5 6.75 26685 KRC400/T/H/960/E M135 12 10000 25000 17500 6000 90 Clear, Daylight Color 111 400 WATTS ED18 Mog 49 110 LUCALOX® HIGH PRESSURE SODIUM LAMPS 35 WATTS B17 Med O U 35 5.43 3.43 11668 LU35/MED 26420 LU35/MED/CP 11669 LU35/D/MED S76 S76 S76 6 4 6 16000 16000 16000 2250 2250 2150 2025 1900 22 2025 1900 22 1935 1900 22 Clear Clear, Consumer Pack Diffuse 111 111 111 Med O U 50 ED23.5 Mog O U 50 5.43 3.43 11345 LU50/MED 26421 LU50/MED/CP 11347 LU50/D/MED 7.75 5 44975 LU50 26425 LU50/CP 45006 LU50/D S68 S68 S68 S68 S68 S68 6 4 6 12 4 12 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 4000 4000 3800 4000 4000 3800 3600 3600 3420 3600 3600 3420 1900 1900 1900 1900 1900 1900 22 22 22 22 22 22 Clear Clear, Consumer Pack Diffuse Clear Clear, Consumer Pack Diffuse 111 111 111 111 111 111 Med O U 70 ED23.5 Mog O U 70 5.43 3.43 11339 LU70/MED 26422 LU70/MED/CP 11340 LU70/D/MED 7.75 5 44033 LU70 26426 LU70/CP 44035 LU70/D S62 S62 S62 S62 S62 S62 6 4 6 12 4 12 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 6400 6400 5950 6400 6400 5950 5450 5450 5050 5450 5450 5050 1900 1900 1900 1900 1900 1900 22 22 22 22 22 22 Clear Clear, Consumer Pack Diffuse Clear Clear, Consumer Pack Diffuse 111 111 111 111 111 111 Med O U 100 ED23.5 Mog O U 100 5.5 3.43 13250 LU100/MED 26423 LU100/MED/CP 13251 LU100/D/MED 7.75 5 44037 LU100 26427 LU100/CP 44038 LU100/D S54 S54 S54 S54 S54 S54 6 4 6 12 4 12 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 9500 9500 8800 9500 9500 8800 8550 8550 7920 8550 8550 7920 2000 2000 2000 2000 2000 2000 22 22 22 22 22 22 Clear Clear, Consumer Pack Diffuse Clear Clear, Consumer Pack Diffuse 111 111 111 111 111 111 Med O U 150 ED23.5 Mog O U 150 ED28 O U 150 5.75 3.5 13252 LU150/MED 26424 LU150/MED/CP 13253 LU150/D/MED 7.75 5 44043 LU150/55 26429 LU150/55/CP 44045 LU150/55/D 8.31 5 44243 LU150/100(ED28) S55 S55 S55 S55 S55 S55 S56 6 4 6 12 4 12 12 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 16000 16000 15000 16000 16000 15000 15000 14400 14400 13500 14400 14400 13500 13500 2000 2000 2000 2000 2000 2000 2000 22 22 22 22 22 22 22 Clear Clear, Consumer Pack Diffuse Clear Clear, Consumer Pack Diffuse Clear 111 111 111 111 111 111 111 O U 200 9.75 5.75 44206 LU200 S66 12 24000+ 22000 19800 2100 22 Clear 111 O U 250 9.75 5.75 44047 LU250 26430 LU250/CP 9 5 44051 LU250/D S50 S50 S50 12 4 12 24000+ 28000 25200 2100 22 24000+ 28000 25200 2100 22 24000+ 26000 23400 2100 22 Clear Clear, Consumer Pack Diffuse 111 111 111 O U 310 9.75 5.75 44053 LU310 S67 12 24000+ 37000 33300 2100 22 Clear 111 50 WATTS B17 70 WATTS B17 100 WATTS B17 150 WATTS B17 Mog 200 WATTS ED18 Mog 250 WATTS ED18 Mog 310 WATTS ED18 Mog For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 3-17 High Intensity Discharge Lamps Bulb Base Order LET OP Watts MOL LCL Code Description ANSI Rated Color Ballast Case Life Lumens Temp. Type Qty. CBCP (hours) Initial Mean K CRI Additional Information Footnotes Warning LUCALOX® HIGH PRESSURE SODIUM LAMPS (CONTINUED) 400 WATTS ED18 Mog ED37 T7 Mog Rx7s O U 400 9.75 5.75 44054 LU400 26431 LU400/CP O U 400 11.31 7 44056 LU400/D O HOR 400 10.12 30244 LU400/TD S51 S51 S51 S51 12 4 6 10 O U 600 11.06 6.62 27187 LU600/T S106 12 O U 750 11.5 6.75 14682 LU750 S111 24000+ 24000+ 24000+ 24000 51000 51000 47500 43000 45000 45000 42750 37300 2100 2100 2100 2000 22 22 22 25 Clear 49 Clear, Consumer Pack 49 Diffuse 49 Clear, Double-ended, Horizontal Burn &#177;20&#176 111 111 111 111 24000+ 90000 81000 2000 22 Clear 49 112 6 24000+ 110000 99000 2100 22 Clear 49 112 S52 S52 6 10 24000+ 130000 126000 2100 22 24000 137500 118200 2000 25 Clear 49 Clear, Double-ended, Horizontal Burn &#177;20&#176 111 111 600 WATTS T15 Mog 750 WATTS ED37 Mog 1000 WATTS E25 T7 Mog Rx7s O U 1000 15.06 8.75 44058 LU1000/ECO O HOR 1000 13.18 30246 LU1000/TD STANDBY LONGLIFE LUCALOX® LAMPS 70 WATTS ED23.5 Mog O U 70 7.75 5 19264 LU70/SBY/XL S62 12 40000 6400 5050 2000 22 Clear, Standby Longlife, Dual Arc Tube 111 O U 100 7.75 5 19265 LU100/SBY/XL S54 12 40000 9500 8190 2000 22 Clear, Standby Longlife, Dual Arc Tube 111 O U 150 7.75 5 19266 LU150/55/SBY/XL S55 12 40000 16000 14000 2000 22 Clear, Standby Longlife, Dual Arc Tube 111 O U 200 9.75 5.75 23431 LU200/SBY/XL S66 12 40000 21500 18150 2000 22 Clear, Standby Longlife, Dual Arc Tube 111 O U 250 9.75 5.75 19270 LU250/SBY/XL S50 12 40000 27500 24750 2000 22 Clear, Standby Longlife, Dual Arc Tube 111 O U 400 9.75 5.75 19272 LU400/SBY/XL S51 12 40000 50000 45000 2000 22 Clear, Standby Longlife, 49 Dual Arc Tube 111 S52 6 40000 127000 115000 2100 22 Clear, Standby Longlife, 49 Dual Arc Tube 111 100 WATTS ED23.5 Mog 150 WATTS ED23.5 Mog 200 WATTS ED18 Mog 250 WATTS ED18 Mog 400 WATTS ED18 Mog 1000 WATTS E25 Mog O U 1000 15.06 8.75 27185 LU1000/SBY/XL ECOLUX® NC NON-CYCLING HIGH PRESSURE SODIUM LAMPS (TCLP COMPLIANT) 70 WATTS ED23.5 Mog O U 70 7.75 5 14672 LU70/ECO/NC S62 12 30000 6300 5670 1900 23 Clear,Non-Cycling,TCLP Compliant 111 O U 100 7.75 5 14673 LU100/ECO/NC S54 12 30000 10500 9450 2000 23 Clear,Non-Cycling,TCLP Compliant 111 O U 150 7.75 5 40390 LU150/ECO/NC S55 12 30000 16000 14400 2000 23 Clear,Non-Cycling,TCLP Compliant 111 O U 200 9.75 5.75 45059 LU200/ECO/NC S66 20 30000 22000 19800 2100 22 Clear,Non-Cycling,TCLP Compliant 111 O U 250 9.75 5.75 14674 LU250/ECO/NC S50 12 30000 29000 26100 2000 30 Clear,Non-Cycling,TCLP Compliant 111 100 WATTS ED23.5 Mog 150 WATTS ED23.5 Mog 200 WATTS ET18 Mog 250 WATTS ED18 3-18 Mog For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B High Intensity Discharge Lamps Bulb Base Order LET OP Watts MOL LCL Code Description ANSI Rated Color Ballast Case Life Lumens Temp. Type Qty. CBCP (hours) Initial Mean K CRI Additional Information Footnotes Warning ECOLUX® NC NON-CYCLING HIGH PRESSURE SODIUM LAMPS (TCLP COMPLIANT) (CONTINUED) 400 WATTS ED18 Mog O U 400 9.75 5.75 14675 LU400/ECO/NC S51 12 30000 54000 48600 2100 30 Clear, Non-Cycling, TCLP Compliant 49 111 ECOLUX® HIGH PRESSURE SODIUM LAMPS (TCLP COMPLIANT) 70 WATTS ED23.5 Mog O U 70 7.75 5 45760 LU70/ECO S62 12 24000+ 6400 5450 1900 22 Clear, TCLP Compliant 111 O U 100 7.75 5 45761 LU100/ECO S54 12 24000+ 9500 8550 2000 22 Clear, TCLP Compliant 111 O U 150 7.75 5 45762 LU150/55/ECO S55 12 24000+ 16000 14400 2000 22 Clear, TCLP Compliant 111 O U 200 9.75 5.75 45763 LU200/ECO S66 12 24000+ 22000 19800 2100 22 Clear, TCLP Compliant 111 O U 250 9.75 5.75 45764 LU250/ECO S50 12 24000+ 28000 25200 2100 22 Clear, TCLP Compliant 111 O U 400 9.75 5.75 45765 LU400/ECO S51 12 24000+ 51000 45000 2100 22 Clear, TCLP Compliant 49 111 S52 6 24000+ 140000 126000 2100 22 Clear 49 111 100 WATTS ED23.5 Mog 150 WATTS ED23.5 Mog 200 WATTS ED18 Mog 250 WATTS ED18 Mog 400 WATTS ED18 Mog 1000 WATTS E25 Mog O U 1000 15.06 8.75 44058 LU1000/ECO LUCALOX® DELUXE 70 WATTS B17 Med HIGH PRESURE SODIUM LAMPS O U 70 5.5 3.5 16611 LU70/DX/MED S62 6 O U O U 150 150 5.75 3.5 18094 LU150/DX/MED 7.75 5 18092 LU150/55/DX S55 S55 O U 250 9.75 5.75 11785 LU250/DX O U 400 9 10000 3800 3040 2200 65 Clear, Improved CRI 111 6 12 15000 10500 15000 10500 9135 2200 65 9135 2200 65 Clear, Improved CRI Clear, Improved CRI 111 111 S50 12 15000 22500 20700 2200 65 Clear, Improved CRI 111 S51 12 15000 37400 34400 2200 70 Clear, Improved CRI 150 WATTS B17 Med ED23.5 Mog 250 WATTS ED18 Mog 400 WATTS ED28 Mog 5.18 19650 LU400/DX 49 111 LUX® E-Z HIGH PRESURE SODIUM LAMPS (MERCURY RETROFIT) 150 WATTS ED28 Mog O U 150 9 5 49943 LUH150/EZ H39 12 13000 12500 12000 1900 22 Clear, Energy-saving 46 BRetrofi t for 175W Mercury 111 O U 215 8.3 5 49939 LUH215/EZ H37 12 /S65 16000 20000 17000 2000 20 Clear, Energy-saving 47 BRetrofi t for 250W Mercury 111 O U 360 11.31 7.12 18012 LUH360/EZ H33 6 24000 45000 40500 2100 25 Clear, Energy-saving 48, 49 BRetrofi t for 400W Mercury 111 8.5 5.37 21294 SOX18 L69 16 18000 1800 1570 1800 0 Clear, Horizontal Burn &#177;20&#176; or Vertical 111 35 12.25 7.25 21296 SOX35 L70 16 18000 4600 4000 1800 0 Clear, Horizontal Burn &#177;20&#176; or Vertical 111 55 16.75 9.5 21297 SOX55 L71 16 18000 7650 6655 1800 0 Clear, Horizontal Burn &#177;20&#176; or Vertical 111 215 WATTS BT28 Mog 360 WATTS BT37 Mog SOX LOW PRESSURE SODIUM LAMPS 18 WATTS T16 BY22d E 18 35 WATTS T16 BY22d E 55 WATTS T16 BY22d E For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 3-19 High Intensity Discharge Lamps Bulb Base Order LET OP Watts MOL LCL Code Description ANSI Rated Color Ballast Case Life Lumens Temp. Type Qty. CBCP (hours) Initial Mean K CRI Additional Information Footnotes Warning SOX LOW PRESSURE SODIUM LAMPS (CONTINUED) 90 WATTS T21 BY22d E 90 20.7511.5 21298 SOX90 L72 9 16000 12750 11095 1800 0 Clear, Horizontal Burn &#177;20&#176; 111 135 30.5 16.37 21299 SOX135 L73 9 16000 22000 19140 1800 0 Clear, Horizontal Burn &#177;20&#176; 111 40W on H45 Ballast, 50W on H46 Ballast, Deluxe White 113 135 WATTS T21 BY22d E MERCURY LAMPS 40/50 WATTS B17 Med O U 50/40 5.12 3.12 12460 HR40/50DX45-46 H45 5 60001575/11401250/9103900 50 O U 75 5.43 3.5 12461 HR75DX43 H43 5 16000 2700 2250 3900 50 Deluxe White 113 Med O U 100 B17 Med ED23.5 Mog O U O U 100 100 R40 O U 100 5.43 3.5 12464 HR100A38/A23 12467 HR100DX38/A23 5.43 3.5 17113 HR100DX38/MED 7.5 5 12471 HR100A38 22575 HR100DX38 26437 HR100DX38/CP 7 36238 HR100RFL38 H38 H38 H38 H38 H38 H38 H38 5 5 5 5 12 4 12 18000 18000 18000 24000+ 24000+ 24000+ 24000+ 3700 4000 4000 3850 4000 4000 2450 2400 2600 2600 2500 2600 2600 2000 113 113 113 113 113 113 113 36495 HR100RDXFL38 H38 12 24000+ 2450 2050 3900 50 Clear Deluxe White Deluxe White Clear Deluxe White Deluxe White, Consumer Pack Reflector Flood, 48&#176; Beam Spread Deluxe White, Reflector WFL, 140&#176; Beam Spread 24048 HR175A39 26440 HR175A39/CP 24062 HR175DX39 26439 HR175DX39/CP 24058 HR175RFL39 H39 H39 H39 H39 H39 12 4 12 4 12 24000+ 24000+ 24000+ 24000+ 24000+ 7850 7850 7800 7800 5700 6830 6830 6800 6800 4800 113 113 113 113 113 33026 HR175RDXFL39 H39 12 24000+ 5700 4350 3900 50 36445 HR175RFL39/M H39 12 24000+ 5700 4800 5700 15 Clear Clear, Consumer Pack Deluxe White Deluxe White, Consumer Pack Clear, Reflector Flood, 40&#176; Beam Spread Deluxe White, Reflector WFL, 120&#176; Beam Spread Clear, Reflector Flood, 40&#176; Beam Spread 24068 HR250A37 32127 HR250DX37 H37 H37 12 12 24000 11000 24000+ 11200 8250 5700 15 8400 3900 50 Clear Deluxe White 113 113 H33 H33 H33 H33 6 6 6 6 24000+ 24000+ 24000+ 24000+ 113 113 113 113 H33 6 24000+ 15500 Deluxe White 49 Clear 49 Deluxe White 49 Reflector, Deluxe White, 49 160&#176; Beam Spread Reflector WFL, Deluxe 49 White, Clear Face, 110&#176; H36 H36 H34 6 6 6 24000+ 57000 28500 5700 15 24000+ 58000 29000 3900 50 16000 58300 29200 3900 50 Clear Deluxe White Deluxe White 113 113 113 75 WATTS B17 Med 100 WATTS A23.5 Med 5700 3800 3900 5700 3900 3900 5700 15 50 50 15 50 50 15 113 175 WATTS ED28 Mog O U 175 8.25 5 R40 Med O U 175 7 5700 5700 3900 3900 5700 15 15 50 50 15 113 113 250 WATTS ED28 Mog O U 250 8.25 5 400 WATTS BT37 ED37 Mog Mog O U O U 400 11.31 7 400 11.31 7 R52 Mog O U 400 11.75 32313 HR400DX33/BT 23974 HR400A33 23998 HR400DX33 33879 HR400RDX33 R60 Mog O U 400 10.12 33938 HR400RDXFL33 22600 21000 22600 20800 14400 13400 14400 13400 3900 5700 3900 3900 50 15 50 50 8950 3900 50 113 1000 WATTS BT56 3-20 Mog O U 1000 15.06 9.5 24171 HR1000A36 24191 HR1000DX36 9.37 32733 HR1000DX34 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 49 49 28, 49 High Intensity Discharge Lamps Bulb Base Order LET OP Watts MOL LCL Code Description ANSI Rated Color Ballast Case Life Lumens Temp. Type Qty. CBCP (hours) Initial Mean K CRI Additional Information Footnotes Warning SAF-T-GARD® MERCURY LAMPS 175 WATTS ED28 Mog O U 175 8.25 5 43391 HT175DX39 H39 12 O U 400 11.31 7 43363 HT400DX33 H33 6 16000 7800 6800 3900 50 Deluxe White 114 24000 22600 14400 3900 50 Deluxe White 49 114 400 WATTS ED37 Mog E-Z MERC® SELF-BALLASTED LAMPS (INCANDESCENT RETROFIT) 160 WATTS ED24 Med O U 160 7 4.5 45178 HSB160/M 24 12000 2300 1600 3900 50 Deluxe White, 120V 9 115 O U 250 8.5 5.18 45174 HSB250M 45176 HSB250 12 12 12000 12000 5000 5000 3750 3900 50 3750 3900 50 Deluxe White, 120V Deluxe White, 120V 9 9 115 115 O U 450 6 16000 9100 8280 3900 50 Deluxe White, 120V 9, 49 115 O U 750 12.75 8.37 44012 HSB750R/120 6 16000 14000 11200 3900 50 Deluxe White, Reflector 9, 49 Flood, 120V, 130&#176; Beam 115 3200 70 3200 70 4000 65 Coated, protected Coated Clear 119 117 117 3900 70 Coated 117 3000 70 RE730 Phosphor Coating 117 4200 65 Clear 117 3900 70 Coated 117 3000 70 RE730 Phosphor Coating 117 4000 65 Clear 49 121 3700 70 Coated 49 121 4000 65 Clear, Vertical Base Up 49 &#177;15&#176; Coated, Vertical Base Up 49 &#177;15&#176; Coated, Vertical Base Up, 49 protected Clear, StayBright®&#174; 49 Coated, StayBright®&#174; 49 RE730 Phosphor Coating 49 121 250 WATTS ED28 Med 450 WATTS BT37 Mog 7.37 40122 HSB450 750 WATTS R57 Mog EXPORT LAMPS METAL HALIDE ED17 E27 ED28 E40 O VBU 32 100 E U 175 E40 1700 5900 8800V 7400H 8400V 7900H 7600V 6500H 13500V 12400H 13000V 11600H 11500V 10600H 23500V 22100H 23000V 19300H 26500 17714 MVR175/SP30/U/40 M57 12 44542 MVR250/U/40 M58 12 44543 MVR250/C/U/40 M58 12 17715 MVR250/SP30/U/40 M58 12 43907 MVR400/U/40 M59 6 43908 MVR400/C/U/40 M59 6 49860 MVR400/VBU/40 M59 6 49857 MVR400/C/VBU/40 M59 6 20000 41000 25000 3700 70 O VBU 400 11.5 7 27738 MPR400/C/VBU/O/40 M59 6 20000 38000 26000 3200 70 S V 400 11.5 7 U 400 11.5 7 46420 MVR400/VBU/STB/40 M59 46421 MVR400/C/VBU/STB/40 M59 17716 MVR400/SP30/U/40 M59 6 6 6 VBU 400 11.5 7 21440 MVR400/SP30/VBU/40 M59 6 18709 MPR400/VBU/O/40 M59 6 20000 40000 26000 3400 65 M47 6 M47 6 11000H 108000V 15000V 100280H 11000H 105000V 15000V 96600H S U 8.25 5 400 11.5 7 400 11.5 7 O VBU 400 11.5 7 E40 10000 2400 15000 8500 6000H 13600V 10000V 11700H 6000H 12900V 10000V 11900H 6000H 12000V 10000V 10300H 6000H 20800V 10000V 19100H 6000H 19800V 10000V 18200H 6000H 18000V 10000V 16600H 15000H 36000V 20000V 33100H 15000H 35000V 20000V 32200H 20000 41000 M57 12 S V BT56 M100 6 M90 6 M57 12 47763 MVR175/C/U/40 250 ED37 5.43 3.43 16893 MXR32/C/VBU/O/27 5.43 3.43 18684 MXR100/C/U/27 8.25 5 47762 MVR175/U/40 S U 1000 15.37 9.5 41828 MVR1000/U/40 41829 MVR1000/C/U/40 20000 41000 20000 41000 15000H 31000V 20000V 28500H 20000 34000 31000 29500 18600V 17100H 20400 4000 65 3700 70 3000 70 3200 70 86000V 4000 65 79000H 80000V 3700 65 73000H 119 121 121 121 RE730 Phosphor Coating, 49 Vertical Base Up &#177;15& Clear, Vertical Base Up 49 &#177;15&#176;, Shrouded A Clear 49 121 Coated 121 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 121 49 121 119 3-21 High Intensity Discharge Lamps Bulb Base Order LET OP Watts MOL LCL Code Description ANSI Rated Color Ballast Case Life Lumens Temp. Type Qty. CBCP (hours) Initial Mean K CRI Additional Information Footnotes Warning EXPORT LAMPS (CONTINUED) LUCALOX® HIGH PRESSURE SODIUM E21 ED23.5 T14.5 ED28 ED18 ED28 ED18 ED37 E25 E27 E40 E40 E40 E40 E40 E40 E40 E40 O O O O O O O O O U U U U U U U U U 70 6.3 4.13 10405 LU70/90/27 150 7.75 5 44044 LU150/55/40 150 8.23 5.16 27223 LU150/100/40 150 9.13 5.24 27228 LU150/100/D/40 250 9.75 5.75 44048 LU250/40 250 9 5 27226 LU250/D/40 400 9.75 5.75 44055 LU400/40 400 11.31 7 27229 LU400/D/40 1000 15.06 8.75 44059 LU1000/40 S55 S50 S50 S51 S51 S52 12 12 12 12 12 12 12 6 6 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 6000 16000 15000 14000 28000 26000 51000 47500 140000 5400 14400 13500 12600 25200 23400 45000 42750 126000 1900 2000 2000 2000 2100 2100 2100 2100 2100 22 22 22 22 22 22 22 22 22 Clear Clear Clear Diffuse Clear Clear Clear Diffuse Clear 49 49 49 111 111 111 111 111 111 111 111 111 E-Z LUX® LUCALOX® HIGH PRESURE SODIUM (MERCURY RETROFIT) ED28 E40 O U 215 9 5 49941 LUH215/D/EZ/40 O U 400 11.42 7.13 32294 HR400DX33/40 12 12000 20200 18600 1900 22 6 24000+ 22600 14400 3900 50 Diffuse, Energy-saving BRetrofi t for 250W Mercury 111 MERCURY ED37 E40 H33 Deluxe White 49 113 Clear Clear Clear Clear Clear 33,38, 33,38, 33,38, 33,38, 33,38, 111 111 111 111 111 HORTICULTURAL LAMPS T15 E40 E41 E42 E43 E44 O O O O O U U U U U 400 600 400 600 750 11.3 11.3 11.3 11.3 11.7 7 6.7 7.1 6.7 7.1 41813 LU400/XO/T/40 41814 LU600/XO/T/40 41845 LU400/XOPSL/T/E40 41850 LU600/XOPSL/T/E40 41856 LU750/XOPSL/T/E40 12 12 12 12 12 28500 28500 28500 28500 16000 56500 90000 56500 90000 112000 53675 85500 53675 85500 106400 2100 2100 2100 2100 2100 22 22 22 22 22 FOOTNOTES 43 # Footnote 9 14 16 17 28 32 33 38 Do not use this lamp in fixtures designed for less than rated lamp wattage. Life shown is for vertical +15° operation. Approximate lumen ratings at 45° burning position: Initial - 145,000. Mean - 124,000. Rated life based on 5 or more burning hours per start. Use only 1000-watt H12 or H34-type ballasts. Do not use on 1000-watt H36-type ballasts. Lamp will run at 400-watts when used on a linear reactor ballast. Rated life based on 11 hours per start. Requires a non-ANSI designated ballast with a special, add-on metal halide ignitor. Contact your local GE representative for a list of approved ballasts and ignitors. UV Control is a quartz material that effectively cuts UVB and UVC radiation. Approximate lumen ratings at 45° burning position: Initial - 153,000. Mean - 139,000. 39 42 44 45 46 47 48 49 50 51 52 . GENERAL INFORMATION FIXTURE REQUIREMENTS – LAMP ENCLOSURE TYPE an area which is unoccupied for extended periods, an enclosed fixture which can contain fragments of hot quartz or glass is recommended. For more information, contact your fixture manufacturer. HID lamps have fixture requirements that must be followed. The following three codes identify the appropriate fixture for a particular lamp. Lamps having an “O” code can be operated in an “Open or Enclosed” fixture. Lamps with a “S” code can be used in open fixtures only if operated in a vertical ±15° burn position. Lamps in all other burn positions must be suitably enclosed. O = Open or Enclosed Fixtures E = Enclosed Fixtures Only S = Lamps operated in a vertical position (Base Up or Down), ±15°, can be used in an open fixture. Lamps burned in any other orientation must be used in “enclosed fixtures only”. Use in Enclosed Fixtures. “Enclosed” fixture means a fixture suitably enclosed and designed to contain fragments of hot quartz or glass (up to 1100°C) per UL Standard #1598 (if in doubt, contact your fixture manufacturer). Use In Open Fixtures. For lamps operated in the vertical position ±15° that are not designated “Enclosed Fixtures Only,” lamp may be used in an open or enclosed lighting fixture depending upon the application and operating environment. For example, if the lamp is located near combustible material or in 3-22 When operated on a 120 hrs. cycle (minimum), lamp life rating may be extended by up to 50% based on engineering estimates. Rated life based on 7 hours per start. Use electronic ballast, peak lead ballast, or system which can shut itself off if ballast overheating occurs. Use only with the following types of H39 175-watt mercury ballasts: high-reactance lag-type autotransformers or 240-volt and 277-volt reactors. Do not use with CW (lead-type) or CWA ballasts. Use only with the following types of H37 250-watt mercury ballasts: high-reactance lag-type autotransformers or 240-volt and 277-volt reactors. Do not use with CW (lead-type) or CWA ballasts. Use only with the following types of H33 400-watt mercury ballasts: high-reactance lag-type autotransformers, reactors, CWA auto regulators or CW regulators. Not for use with lampholders that have stainless steel center contacts to avoid lamp or lampholder damage due to arcing. Not for use on Magnetic-Regulator or Electronic-Regulator ballast systems to avoid ballast overheating. Use only with electronic ballast. Use only with approved ballast. PROTECTION OF BULBS FROM MOISTURE Outer bulbs of HID lamps are made of heat-resistant glass, designed to have strength and thermal-shock-resistant characteristics suitable for normal applications in typical luminaries. However, shielding of lamps must be provided to avoid bulb breakage that could result from direct contact with liquids (such as water) during operation. RATED LIFE Values are based on laboratory tests of a large number of representative lamps under controlled conditions, including operation at 10 hours per start on ballasts having specified electrical characteristics. Individual lamps or groups of lamps may, of course, vary from the Rated Life shown. Lamp operating conditions can also affect life. Where Rated Life is less than 24,000 hours, it is a MEDIAN value of life expectancy; that is, the total operating time at which, under normal operating conditions, 50% of any large group of initially installed lamps is expected to be still burning. Where Rated Life is 24,000+ hours, 67% of lamps are expected to be still burning at 24,000 hours. For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B High Intensity Discharge Lamps GENERAL INFORMATION (CONTINUED) RESTART CHARACTERISTICS For cost-of-light calculations involving these lamps, if an estimated operating time is required at which 50% of the lamps will still be burning, a value of 28,500 hours is suggested. At burning cycles shorter than 10 hours per start, the median life will be shortened as follows: 5 hrs/start: approx. life 75% of rating 21⁄2 hrs/start: approx. life 56% of rating 11⁄4 hrs/start: approx. life 42% of rating With a power interruption of a half cycle or more, the arc will extinguish. When power is immediately reapplied, full light output does not occur immediately. For HPS lamps there is a delay of 1 minute to reach 90% total light output; however, Lucalox® LU1000 requires 2 minutes and E-Z Lux® lamps require 3 minutes to reach 90% total light output. For most Metal Halide lamps, including CMH®, when the power is immediately reapplied, there will be a delay of 10 to 17 minutes before the lamps reach the 90% light output level. PulseArc® lamps restrike in <4 minutes. The restart delay for mercury lamps is 3 to 6 minutes to reach 90% total light output. LUMENS– LUMENS LISTED ARE REFERENCE LUMENS Rated average lamp lumens are obtained under controlled laboratory conditions in a prescribed burning position. Initial Reference Lumens refer to the lamp lumen output after 100-hours burning. Mean Reference Lumens refer to the lamp lumen output at the mean lumen point during lamp life. The mean lumen point occurs at 50% rated life for HPS and mercury lamps, and at 40% rated life for metal halide lamps. Lamp performance on typical systems under typical service conditions will vary from the reference lumen ratings. High Intensity Discharge lighting systems are subject to a wide range of variations which may affect final lighting levels. As a result, lamp performance on actual systems may vary due to lamp orientation, ambient temperatures, ballast variations, line voltage and other reasons. Care must be taken when choosing a system to consider how these changes can affect your light levels both initially and at the mean lumen point. OPERATING POSITIONS AND CODES Mercury and High Pressure Sodium lamps may be operated in any burn position and will still maintain their rated performance specifications. Metal Halide and Low Pressure Sodium lamps, however, are optimized for performance in specific burn positions, or may be restricted to certain burn positions for safety reasons. U = Universal burning position HBU = Horizontal -15° to Base Up HBD = Horizontal +15° to Base Down HOR = Horizontal ±15° H45 = Horizontal to ±45° only VBU = Vertical Base Up ±15° VBD = Vertical Base Down ±15° If no special burn position is noted, the burn position is universal. BALLASTS HID lamps (except E-Z-Merc®) require auxiliary ballast equipment designed to produce proper electrical values. Actual lamp watts may vary depending on ballast characteristics. For total system watts, add nominal ballast watts. All Lucalox®, Mercury, and Metal Halide lamps (except I-Line) will start at ambient temperatures of -22°F (-30°C). I-Line Multi-Vapor® will start at ambient temperatures of 5°F (-15°C) when used on approved mercury ballasts. HID COLOR The color temperature and CRI listed in the tabular data are for reference purposes only. All high intensity discharge lamps exhibit some degree of lamp to lamp color variation and shift over life. These characteristics can be increased based on choice of fixture, ballast, burning position, and ambient conditions. Color variation can be greater than normal during the initial 100 hours of burning. Where color consistency is important, consider using ConstantColor® CMH® for better performance (page 3-9). Contact your local GE Lighting representative for more information. START CHARACTERISTICS Full light output does not occur immediately when power is applied. Instead, there is a time delay for the lamp to reach 90% total light output. The starting delay for High Pressure Sodium is 3-4 minutes, for Metal Halide 2-5 minutes, and for Mercury 5-7 minutes. EXPORT BASE LAMPS (/27 AND /40) Export only lamps have a non-domestic (non-U.S.) base and are not intended for use in the United States due to potential shock hazard. The lamps are identified by “/27” or “/40” at the end of the lamp description and comply with electrical characteristics defined by IEC standards. OPERATING NOTES MXR32 METAL HALIDE LAMP AND ELECTRONIC BALLAST CMH® CHROMAFIT TM METAL HALIDE LAMPS MXR32 lamps must be operated on GE’s special, high power factor electronic ballast, HAL32/120. Outside dimensions for the ballast are 91⁄4’’ long, 31⁄8’’ wide and 13⁄4’’ high. Use in enclosed luminaire with front cover made of glass, capable of containing the fragments of a lamp should it shatter, to avoid risk of fire. Do not use with Polymeric Lens. SAF-T-GARD® MULTI-VAPOR® AND SAF-T-GARD® MERCURY LAMPS E-Z LUX® LAMPS These high pressure sodium lamps should be operated only on certain mercury ballasts, as indicated below. LUH110/EZ: use only with the following types of 125-watt mercury ballasts: high-reactance lag-type autotransformers or 220-volt or greater reactors. LUH150/EZ: use only with the following types of H39 175-watt mercury ballasts: high-reactance lag-type autotransformers or 240-volt and 277-volt reactors. Do not use with CW (lead-type) or CWA ballasts. LUH215/EZ: use only with the following types of H37 250-watt mercury ballasts: high reactance lag-type autotransformers or 240-volt and 277-volt reactors. Do not use with CW (lead-type) or CWA ballasts. LUH360/EZ: use only with the following types of H33 400-watt mercury ballasts: high-reactance lag-type autotransformers, reactors, CWA auto regulators or CW regulators. Caution: If the outer glass envelope of a Saf-T-Gard® lamp is broken, the arc tube will self-extinguish, but the supporting structure will still be electrically connected. Be sure power is off and the lamp has cooled before removing the lamp to avoid possible electrical shock from contact with the arc tube support and to avoid risk of burn from the hot arc tube. ARCSTREAM® METAL HALIDE LAMPS Arcstream® tubular-shaped lamps must be used in suitably-enclosed fixtures with UV-absorbing cover glass. Enclosed fixtures must be capable of containing fragments of hot quartz or glass (up to 1100°C) in the unusual event of the outer bulb shattering. Also see complete Warning and Caution Notices on metal halide lamps. For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 3-23 High Intensity Discharge Lamps WARNING NOTICES THE FOLLOWING WARNING NOTICES MUST BE COMPLIED WITH TO HELP AVOID POSSIBLE LAMP RUPTURE. General Electric Company will not be responsible for poor lamp performance, personal injury or property damage resulting from failure to follow these instructions. Mercury Lamps HID LAMPS - GENERAL WARNING Most HID lamps are constructed of an outer bulb with an internal arc tube made of quartz. The arc tube operates under high pressure at very high temperatures - as high as approximately 1100°C. The arc tube and outer bulb may unexpectedly rupture due to internal causes or external factors such as a system failure or misapplication. An arc tube rupture can burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot quartz particles (as high as 1100°C). There is a risk of personal injury, property damage, burns and fire. Some lamps are position-sensitive and must only be operated in specified burning positions (see “Additional Information” column in this catalog) with compatible electrical equipment in the types of fixtures prescribed in “Lamp Enclosure Type” on Page 3-22 of this catalog. In addition to the general warnings above, there are specific warnings for the HID lamp types listed below. Metal Halide Lamps Fixture lens/diffuser material must be able to contain fragments of hot quartz or glass (up to 1100°C). If you do not know whether your fixture can safely withstand an arc tube rupture, contact your fixture manufacturer. In continuously-operating systems (24 hours/day, 7 days/week), turn lamps off once per week for at least 15 minutes. FAILURE TO COMPLY INCREASES THE RISK OF RUPTURE. Relamp fixtures at or before the end of rated life. Beyond rated life, light output diminishes while energy consumption and risk of rupture increase. High Pressure Sodium Lamps This is a vacuum jacket lamp and may implode if broken. As a precaution, wear safety glasses and gloves when installing or removing lamp. High pressure sodium lamps are not position-sensitive and may be operated in any burning position. Fixture lens/diffuser material must be able to contain fragments of hot quartz or glass (up to 1100°C). If you do not know whether your fixture can safely withstand an arc tube rupture, contact your fixture manufacturer. Relamp fixtures at or before the end of rated life. Beyond rated life, light output diminishes while energy consumption and risk of rupture increase. Mercury lamps are not position-sensitive and may be operated in any burning position. Low Pressure Sodium Lamps These lamps contain sodium which will ignite when exposed to water. If lamps are not disposed of properly, there is a risk of fire in the disposal vessel. Consult GE for disposal instructions. LAMP ENCLOSURE TYPE Use in Enclosed Fixtures. “Enclosed” fixture means a fixture suitably enclosed and designed to contain fragments of hot quartz or glass (up to 1100°C) in accordance with UL Standard #1572 (if in doubt, contact your fixture manufacturer). Use In Open Fixtures. For lamps operated in the vertical position ±15° that are not designated “Enclosed Fixtures Only,” lamp may be used in an open or enclosed lighting fixture depending upon the application and operating environment. For example, if the lamp is located near combustible material or in an area which is unoccupied for extended periods, an enclosed fixture which can contain fragments of hot quartz or glass is recommended. For more information, contact your fixture manufacturer. IMPORTANT NOTICE In accordance to Federal Regulations (21 CFR 1040.30), the following notice applies to all lamps in the HID section of this catalog except High Pressure, Low Pressure Sodium Lamps, and Saf-T-Gard® Multi-Vapor Lamps. “R WARNING: This lamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation if outer envelope of the lamp is broken or punctured, and the arc tube continues to operate. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain types of lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available.” WARNING AND CAUTION NOTICES • Do not use where directly exposed to water or outdoors without an enclosed fixture • Use in enclosed fixture rated for this product • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Operate lamp only in specified position • Turn lamp off at least once for 15 minutes per week • Do not turn on lamp until fully installed CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Wear safety glasses and gloves when handling lamp • Do not use lamp if outer glass is scratched or broken • Do not use excessive force when installing lamp 101 - Arcstream® WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product • Use thermally protected ballast A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass bulb is broken. Remove and dispose of lamp. Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage 3-24 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B High Intensity Discharge Lamps WARNING AND CAUTION NOTICES (CONTINUED) 102 - Arcstream® G12 CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Wear safety glasses and gloves when handling lamp • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not use excessive force when installing lamp WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product - Use thermally protected ballast Lamp emits UV radiation which may cause eye/skin injury. • Avoid exposure of eyes and skin to unshielded lamp Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not touch glass with bare hands • Do not use where directly exposed to water or outdoors without an enclosed fixture • Use in enclosed fixture rated for this product • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Turn lamp off at least once for 15 minutes per week • Do not turn on lamp until fully installed CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Do not use excessive force when installing lamp 104 - CMH® GU6.5, G12 and Mini WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product • Use fused or thermally protected ballast – see instructions A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass bulb is broken. Remove and dispose of lamp. Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Normal handling with bare hands is acceptable. Excessive handling of the quartz outer bulb should be avoided. • Do not use where directly exposed to water or outdoors without an enclosed fixture • Use in enclosed fixture rated for this product • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Do not use beyond rated life • Do not turn on lamp until fully installed CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Do not use excessive force when installing lamp 103 - Arcstream® Rx7s WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product • Use thermally protected ballast A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass bulb is broken. Remove and dispose of lamp. Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not touch glass with bare hands • Do not use in wet locations • Use in enclosed fixture rated for this product • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Operate lamp only in specified position • Turn lamp off at least once for 15 minutes per week • Do not turn on lamp until fully installed For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 3-25 High Intensity Discharge Lamps WARNING AND CAUTION NOTICES (CONTINUED) 105 - CMH® HW HPS WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product • Use electronic ballast, peak lead ballast, or system which can shut itself off if ballast overheating occurs. Does not apply to CMH 250/R. A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass bulb is broken. Remove and dispose of lamp. Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not use where directly exposed to water or outdoors without an enclosed fixture • Use in enclosed luminaire with front cover made of glass, capable of containing the fragments of a lamp should it shatter, to avoid risk of fire. Do not use with Polymeric Lens. • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Do not use beyond rated life • Do not turn on lamp until fully installed CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Wear safety glasses and gloves when handling lamp • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not use excessive force when installing lamp 106 - CMH® HW PA WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass bulb is broken. Remove and dispose of lamp. Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not use where directly exposed to water or outdoors without an enclosed fixture • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Operate lamp only in specified position • Do not store flammable materials near/below lamp • Do not use beyond rated life • Do not turn on lamp until fully installed 3-26 CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not use excessive force when installing lamp 107 - CMH® MR16 and PAR20-30 WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product • Use fused or thermally protected ballast - see instructions Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not use where directly exposed to water or outdoors without an enclosed fixture • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Do not store flammable materials near/below lamp • Do not use beyond rated life • Do not turn on lamp until fully installed CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Do not use excessive force when installing lamp 108 - CMH® PAR38 WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass bulb is broken. Remove and dispose of lamp. Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Do not turn on lamp until fully installed For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B High Intensity Discharge Lamps WARNING AND CAUTION NOTICES (CONTINUED) CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Operate lamp only in specified position • Turn lamp off at least once for 15 minutes per week - Do not turn on lamp until fully installed CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Wear safety glasses and gloves when handling lamp • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not use excessive force when installing lamp 109 - CMH® TD WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product A damaged lamp emits UV radiation which may cause eye/skin injury - Turn power off if glass bulb is broken. Remove and dispose of lamp. Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Normal handling with bare hands is acceptable. Excessive handling of the quartz outer bulb should be avoided. • Do not use where directly exposed to water or outdoors without an enclosed fixture • Use in enclosed fixture rated for this product • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Operate lamp only in specified position • Do not use beyond rated life • Do not turn on lamp until fully installed CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Do not use excessive force when installing lamp 111 - Lucalox® WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product Contains sodium – chemical burn risk • Avoid skin contact with broken pieces Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not use where directly exposed to water or outdoors without an enclosed fixture • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Do not store flammable materials near/below lamp • Do not turn on lamp until fully installed CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Wear safety glasses and gloves when handling lamp • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not use excessive force when installing lamp 110 - Arcstream®, Kolorarc® WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp - Use in fixture rated for this product A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass bulb is broken. Remove and dispose of lamp. Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not use where directly exposed to water or outdoors without an enclosed fixture • Use in enclosed fixture rated for this product • Do not use lamp if outer glass is scratched or broken For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 3-27 High Intensity Discharge Lamps WARNING AND CAUTION NOTICES (CONTINUED) 112 - Lucalox® HO CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not use excessive force when installing lamp WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product • Use fused or thermally protected ballast - see instructions Contains sodium – chemical burn risk • Avoid skin contact with broken pieces Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not use where directly exposed to water or outdoors without an enclosed fixture • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Do not store flammable materials near/below lamp • Do not turn on lamp until fully installed CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Wear safety glasses and gloves when handling lamp • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not use excessive force when installing lamp 114 - Mercury Saf-T-Gard® 113 - Mercury WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass bulb is broken. Remove and dispose of lamp. Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not use where directly exposed to water or outdoors without an enclosed fixture • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Do not store flammable materials near/below lamp • Do not use beyond rated life • Do not turn on lamp until fully installed 3-28 WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not use where directly exposed to water or outdoors without an enclosed fixture • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Turn lamp off at least once for 15 minutes per week • Do not store flammable materials near/below lamp • Do not use beyond rated life • Do not turn on lamp until fully installed CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not use excessive force when installing lamp 115 - Mercury Self-Ballasted WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass bulb is broken. Remove and dispose of lamp. Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not use where directly exposed to water or outdoors without an enclosed fixture • Use in enclosed fixture rated for this product • Do not use lamp if outer glass is scratched or broken For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B High Intensity Discharge Lamps WARNING AND CAUTION NOTICES (CONTINUED) CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not use excessive force when installing lamp Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not use where directly exposed to water or outdoors without an enclosed fixture • Use in enclosed fixture rated for this product • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Operate lamp only in specified position • Turn lamp off at least once for 15 minutes per week • Do not use beyond rated life • Do not remove base locating pin if so equipped • Do not turn on lamp until fully installed CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not use excessive force when installing lamp 116 - QMH E-rated Kr85 and CMH® WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass bulb is broken. Remove and dispose of lamp. Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not use where directly exposed to water or outdoors without an enclosed fixture • Use in enclosed fixture rated for this product • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Operate lamp only in specified position • Turn lamp off at least once for 15 minutes per week. Does not apply to CMH. • Do not use beyond rated life • If used on a dimming system, see instructions. • Do not turn on lamp until fully installed CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not use excessive force when installing lamp 118 - QMH LW Kr85 WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass bulb is broken. Remove and dispose of lamp. Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not use where directly exposed to water or outdoors without an enclosed fixture • Use in enclosed fixture rated for this product • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Turn lamp off at least once for 15 minutes per week • Do not use beyond rated life • Do not turn on lamp until fully installed CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not use excessive force when installing lamp 117 - QMH HOR Enclosed WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass bulb is broken. Remove and dispose of lamp. For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 3-29 High Intensity Discharge Lamps WARNING AND CAUTION NOTICES (CONTINUED) 119 - QMH Protected WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass bulb is broken. Remove and dispose of lamp. Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not use where directly exposed to water or outdoors without an enclosed fixture • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Operate lamp only in specified position • Turn lamp off at least once for 15 minutes per week • Do not store flammable materials near/below lamp • Do not use beyond rated life • If used on a dimming system, see instructions. • Do not turn on lamp until fully installed CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not use excessive force when installing lamp 120 - QMH Protected Kr85 WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass bulb is broken. Remove and dispose of lamp. Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not use where directly exposed to water or outdoors without an enclosed fixture • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Operate lamp only in specified position • Turn lamp off at least once for 15 minutes per week • Do not store flammable materials near/below lamp • Do not use beyond rated life • Do not turn on lamp until fully installed 3-30 CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not use excessive force when installing lamp 121 - QMH S-rated WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass bulb is broken. Remove and dispose of lamp. Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not use where directly exposed to water or outdoors without an enclosed fixture • Use in enclosed fixture rated for this product – see instructions • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Operate lamp only in specified position • Turn lamp off at least once for 15 minutes per week • Do not store flammable materials near/below lamp • Do not use beyond rated life • If used on a dimming system, see instructions. • Do not turn on lamp until fully installed CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Wear safety glasses and gloves when handling lamp • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not use excessive force when installing lamp For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B High Intensity Discharge Lamps WARNING AND CAUTION NOTICES (CONTINUED) CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not use excessive force when installing lamp 122 - QMH S-rated Kr85 WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass bulb is broken. Remove and dispose of lamp. Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not use where directly exposed to water or outdoors without an enclosed fixture • Use in enclosed fixture rated for this product – see instructions • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Operate lamp only in specified position • Turn lamp off at least once for 15 minutes per week • Do not store flammable materials near/below lamp • Do not use beyond rated life • If used on a dimming system, see instructions. • Do not turn on lamp until fully installed CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not use excessive force when installing lamp 124 - Sport 1000W PAR64 WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass bulb is broken. Remove and dispose of lamp. Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not use where directly exposed to water or outdoors without an enclosed fixture • Use in enclosed fixture rated for this product • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Operate lamp only in specified position • Turn lamp off at least once for 15 minutes per week • Do not turn on lamp until fully installed CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Wear safety glasses and gloves when handling Lamp • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not use excessive force when installing lamp 123 - QMH S-rated Saf-T-Gard® WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not use where directly exposed to water or outdoors without an enclosed fixture • Use in enclosed fixture rated for this product – see instructions • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Operate lamp only in specified position • Turn lamp off at least once for 15 minutes per week • Do not store flammable materials near/below lamp • Do not use beyond rated life • Do not turn on lamp until fully installed For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 3-31 High Intensity Discharge Lamps WARNING AND CAUTION NOTICES (CONTINUED) 125 - Sport MBIL-CSI-CID • Do not use where directly exposed to water or outdoors without an enclosed fixture • Use in enclosed fixture rated for this product • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Operate lamp only in specified position • Turn lamp off at least once for 15 minutes per week • Do not turn on lamp until fully installed CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Do not use excessive force when installing lamp WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product Lamp emits UV radiation which may cause eye/skin injury. • Avoid exposure of eyes and skin to unshielded lamp Unexpected lamp rupture may cause injury, fire, or property damage • Do not exceed rated voltage • Do not touch glass with bare hands HID LAMPS CROSS REFERENCE GE Description Osram/Sylvania Description GE Description Philips Description 3-32 Lumalux® LU35/MED LU35/D/MED LU50/MED LU50/D/MED LU50/ECO LU50/D LU70/MED LU70/D/MED LU70/ECO LU70/PLUS/ECO LU70/D LU100/MED LU100/D/MED LU100/ECO LU100/PLUS/ECO LU100/D LU150/55/MED LU150/55/D/MED LU150/55/ECO LU150/55/PLUS/ECO LU150/55/D LU150/100 LU200/ECO LU200/PLUS/ECO LU250/ECO LU250/PLUS/ECO LU250/D Philips Description ORDER THIS IF YOU CURRENTLY USE GE LAMP THESE LAMPS STANDARD AND ECOLUX® HPS LAMPS (CONTINUED) ORDER THIS IF YOU CURRENTLY USE GE LAMP THESE LAMPS STANDARD AND ECOLUX® HPS LAMPS Lucalox® LU35/MED LU35/D/MED LU50/MED LU50/D/MED LU50 LU50/D LU70/MED LU70/D/MED LU70/ECO LU70/ECO/NC LU70/D LU100/MED LU100/D/MED LU100/ECO LU100/ECO/NC LU100/D LU150/MED LU150/D/MED LU150/55/ECO LU150/ECO/NC LU150/55/D LU150/100 LU200/ECO LU200/ECO/NC LU250/ECO LU250/ECO/NC LU250/D Osram/Sylvania Description Lucalox® LU310 LU400/ECO LU400/ECO/NC LU400/D LU750 LU1000/ECO Ceramalux™ C35S76/M C35S76/D/M C50S68/M C50S68/M C50S68/ALTO C50S68/D C70S62/M C70S62/D/M C70S62/ALTO — C70S62/D C100S54/M C100S54/D/M C100S54/ALTO — C100S54/D CC150S55/M C150S55/D/M C150S55/ALTO — C150S55/D C150S56/ALTO C200S66 — C250S50 — C250S50/D Lumalux® LU310/ECO LU400/ECO LU400/PLUS/ECO LU400/D LU750 LU1000 Ceramalux™ C310S67 C400S51 — C400S51/D — C1000S52 DELUXE HIGH PRESSURE SODIUM LAMPS Lucalox® LU70/DX/MED LU150/DX/MED LU150/55/DX LU250/DX LU400/DX — — — — — Ceramalux™ C70S62/C/M C150S55/C/M C150S55/C C250S50/C C400S51/C STANDBY LONGLIFE HIGH PRESSURE SODIUM LAMPS Lucalox® LU70/SBY/XL LU100/SBY/XL LU150/55/SBY/XL LU200/SBY/XL LU250/SBY/XL LU400/SBY/XL LU1000/SBY/XL Lumalux® LU70/SBY LU100/SBY LU150/551SBY LU200/100/SBY LU250/SBY LU400/SBY LU1000/SBY Ceramalux™ C70S62/2 C100S54/2 C150S55/2 — C250S50/2 C400S51/2 C1000S52/2 EZ-LUX® HIGH PRESSURE SODIUM LAMPS E-Z LUX® LUH150/EZ LUH215/EZ LUH360/EZ Unalux® ULX150 UlX215 ULX360 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Ceramalux™ C150S63 RETROLUX C215S675 RETROLUX C360S64 RETROLUX High Intensity Discharge Lamps HID LAMPS CROSS REFERENCE (CONTINUED) GE Description Osram/Sylvania Description GE Description Philips Description Osram/Sylvania Description Philips Description ORDER THIS IF YOU CURRENTLY USE GE LAMP THESE LAMPS CERAMIC METAL HALIDE LAMPS ORDER THIS IF YOU CURRENTLY USE GE LAMP THESE LAMPS CERAMIC METAL HALIDE LAMPS (CONTINUED) CMH20/MR16/830/SP CMH20/MR16/830/FL CMH20/MR16/830/WFL CMH20/PAR20/SP CMH20/PAR20/FL CMH20/PAR30/SP10 CMH20/PAR30/SP15 CMH20/PAR30/FL25 CMH39/PAR20/830/SP10 CMH39/PAR20/830/FL30 CMH39/PAR30L/830/SP10 CMH39/PAR30L/830/SP15 CMH39/PAR30L/830/FL25 CMH70/PAR30L/830/SP15 CMH70/PAR30L/830/FL40 CMH70/PAR38/830/SP15 CMH70/PAR38/830/FL25 CMH70/PAR38/830/WFL CMH100/PAR38/830/SP15 CMH100/PAR38/830/FL25 CMH100/PAR38/830/WFL CMH70/U/830/MED CMH70/C/U/830/MED CMH100/U/830/MED CMH100/C/U/830/MED CMH70/U/830/MED/O CMH70/C/U/830/MED/O CMH70/U/942/MED/O CMH70/C/U/942/MED/O CMH150/U/830/MED/O CMH150/C/U/830/MED/O CMH150/U/942/MED/O CMH150/C/U/942/MED/O CMH20/T/U/830/G12 CMH39/T/U/830/G12 CMH39/TC/U/942/G12 CMH70/T/U/830/G12 CMH70/T/U/942/G12 CMH150/T/U/830/G12 CMH150/T/U/942/G12 CMH70/TD/830/Rx7s CMH70/TD/942/Rx7s CMH150/TD/830/Rx7s CMH150/TD/942/Rx7s CMH250/PA/O-SPXX CMH320/PA/O-SPXX CMH350/PA/O-SPXX CMH400/BU/PA/O-SPXX CMH20/TC/U/830/GU6.5 CMH20/TC/U/830/G8.5 CMH39/TC/U/830/G8.5 CMH39/TC/U/942/G8.5 CMH70/TC/U/830/G8.5 CMH70/TC/U/942/G8.5 — — — — — MCP20PAR30LN/U/830/SP — MCP20PAR30LN/U/830/FL MCP39PAR20/U/830/SP MCP39PAR20/U/830/FL MCP39PAR30LN/U/830/SP — MCP39PAR30LN/U/830/FL MCP70PAR30LN/U/830/SP MCP70PAR30LN/U/830/FL MCP70PAR38/U/830/SP MCP70PAR38/U/830/FL MCP70PAR38/U/830/WFL MCP100PAR38/U/830/SP MCP100PAR38/U/830/FL MCP100PAR38/U/830/WFL MCP70/U/MED/830 MCP70/C/U/MED/830 MCP100/U/MED/830 MCP100/C/U/MED/830 MCP70/U/MED/830 MCP70/C/U/MED/830 — — MCP150/U/MED/830 MCP150/C/U/MED/830 — — — MC39T6/U/G12/830 MC39T6/U/G12/940 MC70T6/U/G12/830 MC70T6/U/G12/940 MC150T6/U/G12/830 MC150T6/U/G12/940 MC70T6/DE/830 — MC150T6/DE/830 — — — — — — — — — CDM35/PAR20/M/SP CDM35/PAR20/M/FL CDM35/PAR30L/M/SP — CDM35/PAR30L/M/FL CDM70/PAR30L/M/SP CDM70/PAR30L/M/FL CDM70/PAR38/SP/3K CDM70/PAR38/FL/3K CDM70/PAR38/WFL/3K CDM100/PAR38/SP/3K CDM100/PAR38/FL/3K CDM100/PAR38/WFL/3K MHC70/U/M/3K MHC70/C/U/M/3K MHC100/U/M/3K MHC100/C/U/M/3K MHC70/U/MP/3K/ALTO MHC70/C/U/MP/3K/ALTO MHC70/U/MP/4K/ALTO MHC70/C/U/MP/4K/ALTO MCH150/U/MP/3K/ALTO MHC150/C/U/MP/3K/ALTO MHC150/U/MP/4K/ALTO MHC150/C/U/MP/4K/ALTO — CDM35/T6/830 — CDM70/T6/830 CDM70/T6/942 CDM150/T6/830 CDM150/T6/942 CDM70/TD/830 CDM70/TD/942 CDM150/TD/830 CDM150/TD/942 MCP250/PS/BU-only/940 MCP320/PS/BU/840/BT37 — — — MC20TC/U/G8.5/830 MC39TC/U/G8.5/830 MC39TC/U/G8.5/942 MC70TC/U/G8.5/830 MC70TC/U/G8.5/942 — CDM320/V/O/PS/4K CDM350/V/O/PS/4K CDM350/V/O/PS/4K — — CDM35/TC/830 CDM35/TC/942 CDM70/TC/830 CDM70/TC/942 MULTI-VAPOR® PULSEARC® METAL HALIDE LAMPS MXR32C/VBU MXR50/U/MED MXR50/C/U/MED MXR70/U/MED MXR70/C/U/MED MXR70/U/MED/O MXR70/C/U/MED/O MXR100/U/MED MXR100/C/U/MED MVR100/U/MED MVR100/C/U/MED MXR100/U/MED/O MXR100/C/U/MED/O MXR150/U/MED MXR150/C/U/MED MVR175/VBU/PA MVR175/C/VBU/PA MVR250/VBU/PA MVR250/C/VBU/PA MVR320/VBU/HO/PA MVR320/C/VBU/HO/PA MPR320/VBU/XHO/PA MPR320/C/VBU/XHO/PA MPR350/VBU/PA MPR350/C/VBU/PA MPR400/VBU/XHO/PA MPR400/C/VBU/XHO/PA MVR750/VBU/PA MVR750/C/VBU/PA MVR1000/BT37/PA — MP50/U/MED MP50/C/U/MED MH70/U/MED MH70/C/U/MED MP70/U/MED MP70/C/U/MED M100/U/MRD MH100/C/U/MED MH100/U/4K/MED — MP100/U/MED MP100/C/U/MED M150/U/MED M150/C/U/MED MS175/PS/BU MS175/C/PS/BU MS250/PS/BU MS250/C/PS/BU MS320/PS/BU MS320/C/PS/BU-HOR MP320/350/PS/BU MP320/350/C/PS/BU MP320/350/PS/BU MP320/350/C/PS/BU MP350/400/PS/BU MP350/400/C/PS/BU MS750/PS/BU-HOR/BT37 MS750/C/PS/BU-HOR/BT37 M1000/PS/U/BT37 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B — MH50/U/M MH50/C/U/M MHC70/U/M/3K MHC70/C/U/M/3K MHC70/C/U/M/3K MHC70/C/U/M/3K MHC100/U/M/3K MHC100/C/U/M/3K MHC100/U/M/4K MHC100/C/U/M/4K MHC100/U/M/3K MHC100/C/U/M/3K MH150/U/M MH150/C/U/M MS175/BU/PS — MS250/BU/PS — MS320/BU/PS MS320/C/BU/PS MP320/BU/PS MP320/C/BU/PS MP350/BU/PS MP350/C/BU/PS MP400/BU/PS MP400/C/BU/PS — — MS1000/BU/BT37/PS 3-33 High Intensity Discharge Lamps HID LAMPS CROSS REFERENCE (CONTINUED) GE Description Osram/Sylvania Description GE Description Philips Description Osram/Sylvania Description Philips Description ORDER THIS IF YOU CURRENTLY USE GE LAMP THESE LAMPS ® MULTI-VAPOR STANDARD METAL HALIDE LAMPS ORDER THIS IF YOU CURRENTLY USE GE LAMP THESE LAMPS MERCURY VAPOR LAMPS MVR175/U/MED MVR175/C/U/MED MVR175/U MVR175/C/U MVR175/HOR MVR175/C/HOR MVR250/U MVR250/C/U MVR250/SP30/U MVR250/HOR MVR250/C/HOR MVR400/U MVR400/C/U MVR400/SP30/U MVR400/VBU MVR400/VBD MVR400/C/VBU MVR400/C/VBD MVR400/HOR MVR400/C/HOR MVR400/SP30/HOR MPR400/U MPR400/VBU MVR1000/U MVR1000/C/U MVR1000/VBU MPR1000/VBU/O MVR1500/U/SPORTS HR40/50DX45-46 HR75DX43 HR75/100PFL43-44 HR100DX38/E17 HR100A38/A23 HR100DX38/A23 HR100A38 HR100DX38 HT100DX38 HR100WDX38 HR100RFL38 HR100RDXFL38 HR100PSP44 HR100PFL44 HR175A39 HR175DX39 HT175DX39 HR175WDX39 HR175RFL39 HR175RDXFL39 HR250A37 HR250DX37 HT250DX37 HR250WDX37 HR400A33 HR400DX33 HR400DX33BT HT400DX33 HR400WDX33 HR400R33 HR400RDX33 HR400RDXFL33 HR400RSP33 HR400A33/T16 HR700DX35 HR1000DX34 HR1000DX34 HR1000A36 HR1000DX36 HT1000DX36 M175/U/MED M175/C/U/MED M175/U M175/C/U MS175/HOR MS175/C/HOR M250/U M250/C/U M2503K/BU-only MS250/HOR MS250/C/HOR M400/U M400/C/U MS400/BU MS400/BU MS400/BD MS400/C/BU MS400/C/BD MS400/HOR MS400/C/HOR MS400/3K/HOR MP400/BU MP400/BU/BD M1000/U M1000/C/U MS1000/BU MP1000/BU M1500/BU-HOR MH175/U/M MH175/C/U/M MH175/U MH175/C/U MS175/HOR MS175/C/HOR MH250/U MH250/C/U MH250/3K/BU MS250/HOR MS250/C/HOR MH400/U MH400/C/U MH400/3K/U MS400/BU — MS400/C/BU& — MS400/HOR MS400/C/HOR — MP400/U — MH1000/U MH1000/C/U MS1000/BU MP1000/BU MH1500BU DOUBLE-ENDED LAMPS ARC70/TD/730/R7S ARC70/TD/743/R7S ARC150/TD/730/R7S ARC150/TD/742/R7S HQI-DE70/WDX — HQI-DE150/WDX HQI-DE150/NDX CDM70/TD/830 MHN70/TD/840 CDM150/TD/830 MHN150/TD/840 SAFETY METAL HALIDE LAMPS MVT400/VBU MVT400/C/VBU MPT400/BU MPT400/C/BU MHT400/U MHT400/C/U H45/46DL-40/50/DX H43AV-75/DX — — — H38AV-100/DX H38HT-100 H38JA-100/DX H38JA-T100/DX H38JA-100/N — H38BP-100/DX H44GS-100 H44JM-100 H39KB-175 H39KC-175/DX H39KC-T175/DX H39KC-175/N — H39BP-175/DX H37KB-250 H37KC-250/DX H37KC-T250/DX H37KC-250/N H33CD-400 H33GL-400/DX — H33GL-T400/DX H33GL-400/N — — — — H33AR-400 — H34GV-1000 H34GW-1000/DX H36GV-1000 H36GW-1000/DX H36GW-T1000/DX H46DL-40-50/DX H43AV-75/DX — — — H38MP-100/DX H38HT-100 H38JA-100/DX H38JA-T100/DX — — H38BP-100/DX H44GS-100 — H39KB-175 H39KC-175/DX H39KC-T175 — H39BM-175 H39BP-175/DX H37KB-250 H37KC-250/DX H37KC-T250/DX — H33CD-400 H33GL-400/DX — H33GL-T400/DX — — H33DN-400/DX H33FS-400/DX — — H35ND-700/DX — H34GW-1000/DX H36GV-1000 H36GW-1000/DX H36GW-T1000/DX SELF-BALLASTED MERCURY VAPOR LAMPS HSB160/M HSB250 HSB250/M HSB450 HSB750R/120 3-34 — — — — — For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B — S250E28/DX S250E28/DX/M S450BT37/C S750R57 Fluorescent Lamps T5 STARCOAT® ECOLUX® LAMPS High Efficiency, High Output ............................................................................................ 4-7 T5 PREHEAT LAMPS ................................................................ 4-8 6" T5, 9" T5, 12" T5, 21" T5.................................................................................................. 4-8 T8 STARCOAT® LAMPS ........................................................... 4-8 2' T8 Ecolux® – TCLP Compliant, 2' T8 Ecolux® XL Extra-Life ............................ 4-8 3' T8 Ecolux® – TCLP Compliant, 3' T8 Ecolux® XL Extra-Life ............................ 4-8 4' T8 Ecolux® – TCLP Compliant ...................................................................................... 4-9 4' T8 Ecolux® XL Extra-Life, 4' T8 Ecolux® Super Long Life ................................. 4-9 Ultra Energy Saving T8 Lamps ........................................................................................ 4-9 4' T8 Ecolux® Watt-Miser®, 4' T8 Ecolux® Watt-Miser® XL Extra-Life ....... 4-9 4' T8 Ecolux® UltraMax™ ................................................................................................ 4-9 4' T8 Ecolux® High Lumen ...........................................................................................4-10 F25T12 Ecolux® for T8 Ballasts .................................................................................4-10 8' T8 Lamps ...........................................................................................................................4-10 8' T8, 8' T8 XL Extra-Life ................................................................................................4-10 8' T8 XL Extra-Life Watt-Miser® Energy Saving Lamps ..................................4-10 8' T8 XL Extra-Life Watt-Miser® Plus Energy Saving Lamps ........................4-10 8' T8 High Output .................................................................................................................4-10 8' T8 HIGH OUTPUT ..............................................................4-10 8' T8 High Output - Recessed Double Contact ......................................................4-10 8' T8 Instant Start ................................................................................................................4-10 T8 MOD-U-LINE ....................................................................4-11 8' 1 5/8" Spacing, 8' 6" Spacing ......................................................................................4-11 OTHER T8 LENGTHS .............................................................4-11 18" T8 w/Starcoat®, 5' T8 w/Starcoat®, 6' T8 InstantStart ................................4-11 SPECIAL APPLICATION LAMPS ............................................4-19 CovRGuard® Shatter Protected ....................................................................................4-19 T5, T6 .....................................................................................................................................4-19 T8 Ecolux® w/Starcoat®................................................................................................4-19 Ultra Energy Saving T8 Lamps w/CovRGuard® .................................................4-20 5' T8 Starcoat® ..................................................................................................................4-20 T8 Instant Start w/Starcoat®......................................................................................4-21 8' T8 High Output Lamps Recessed Double Contact w/Starcoat®...........4-21 T8 Preheat Lamps, T12 Rapid Start Lamps .........................................................4-21 T12 Instant Start ..............................................................................................................4-22 T12 Instant Start – Watt-Miser® Energy Saving Lamps ................................4-22 T12 Mod-U-Line – Watt-Miser® Energy Saving Lamps ..................................4-22 T12 Mod-U-Line 6" Spacing ........................................................................................4-22 T12 Preheat ........................................................................................................................4-23 T12 High Output Lamps Recessed Double Contact ........................................4-23 T12 High Output Lamps Recessed Double Contact– Watt-Miser® Energy Saving Lamps ....................................................................................................................4-23 Cold Temperature ...............................................................................................................4-23 T5, T8 .....................................................................................................................................4-23 Instant Start .......................................................................................................................4-24 High Output (800mA) Recessed Double Contact ..............................................4-24 T10 Very High Output (1500mA) Recessed Double Contact........................4-24 T12 Very High Output (1500mA) Recessed Double Contact........................4-24 Diazo Reprographic 1500mA (Superblue) ................................................................4-24 T12, T17 ................................................................................................................................4-24 Appliance ................................................................................................................................4-24 T8, T12...................................................................................................................................4-25 BLACKLIGHT/BLACKLIGHT BLUE .......................................4-25 COLORED LAMPS T8 POLYLUX ...........................................................................4-11 2' T8 Polylux, 4' T8 Polylux, 6' T8 Polylux, 7' T8 Polylux .......................................4-11 T8 PREHEAT ...........................................................................4-11 12" T8, 15" T8, 18" T8..........................................................................................................4-11 36' T8 Polylux .........................................................................................................................4-12 T12 LAMPS 3' T12 Ecolux® - Rapid Start ............................................................................................4-12 25W, 30W ............................................................................................................................4-12 4' T12 Rapid Start ................................................................................................................4-12 32W Watt-Miser® Plus ..................................................................................................4-12 34W Watt-Miser® Ecolux® - TCLP Compliant .....................................................4-12 40W Ecolux® - TCLP Compliant, 40W Ecolux® XL Extra-Life .......................4-13 25W Ecolux® Utility Shoplight....................................................................................4-13 T12 Mod-U-Line® ................................................................................................................4-14 T12 35/8" Spacing, T12 6" Spacing ...........................................................................4-14 Watt-Miser® Energy Saving Lamps.........................................................................4-14 T12 Instant Start ..................................................................................................................4-14 Watt-Miser® Energy Saving Lamps.........................................................................4-14 8' T12 Instant Start..............................................................................................................4-14 8' Instant Start Standard ..............................................................................................4-14 8' Instant XL Extra-Life ..................................................................................................4-15 Watt-Miser® Energy Saving Lamps.........................................................................4-15 T12 Other Lengths ..............................................................................................................4-15 5' T12 Instant Start, 64" Instant ................................................................................4-15 6' T12 Instant Start, 7' T12 Instant Start ...............................................................4-15 T12 High Output (800mA) Rapid Start Recessed Double Contact ................4-16 18" High Output, 2' High Output, 30" High Output, 3' High Output .........4-16 42" High Output, 4' High Output ..............................................................................4-16 4' High Output Watt-Miser® Energy Saving Lamps .........................................4-16 5' High Output, 64" High Output ..............................................................................4-16 6' High Output, 7' High Output, 8' High Output .................................................4-17 8' High Output Watt-Miser® Energy Saving Lamps .........................................4-17 8' High Output Watt-Miser® Ecoloux® ...................................................................4-17 T12 Very High Output (800mA) Rapid Start Recessed Double Contact .....4-17 T12 Preheat ............................................................................................................................4-18 15", 18", 24" ........................................................................................................................4-18 T8 ................................................................................................................................................4-25 T12, Preheat ...........................................................................................................................4-26 GOLD ......................................................................................4-25 T5 ................................................................................................................................................4-25 T8, T12 ......................................................................................................................................4-26 GROCERY DISPLAY LAMPS ..................................................4-26 GERMICIDAL ..........................................................................4-26 PLANT AND AQUARIUM/TERRARIUM ................................4-26 T8 ................................................................................................................................................4-27 15" T8, 18" T8, 36" T8......................................................................................................4-27 T12 ..............................................................................................................................................4-27 24" T12, 36" T12, 48" T12..............................................................................................4-27 EXPORT OUTSIDE U.S. AND CANADA ONLY......................4-27 CONSUMER PRODUCTS T8 ................................................................................................................................................4-28 4'T8, 8'T8 ..............................................................................................................................4-28 T12 ..............................................................................................................................................4-28 4' F40 Ecoloux® Standard, 4' Ecoloux® Utility Shoplight................................4-28 4' F34 Watt-Miser® Energy Saving Lamps ...........................................................4-28 Mod-U-Line Watt-Miser® U-Tubes ..........................................................................4-28 Mod-U-Line Standard U-Tubes .................................................................................4-28 T12 Instant Start, T12 Rapid Start ...........................................................................4-28 T12 High Output Rapid Start Recessed Double Contact...............................4-29 Preheat .....................................................................................................................................4-29 T5, T8, T12 ...........................................................................................................................4-29 Blacklight, Blacklight/Blacklight Blue .....................................................................4-30 T9 Circline ...............................................................................................................................4-30 CovRguard® Shatter Resistant ......................................................................................4-30 T8 Preheat, T12 Rapid Start, T12 Rapid Start Watt-Miser®, ........................4-30 T12 Preheat, T12 Instant Start Plant and Aquarium/Terrarium.....................................................................................4-30 OPERATING NOTES ...............................................................4-31 GENERAL INFORMATION .....................................................4-32 WARNING AND CAUTION NOTICES ...................................4-33 CROSS REFERENCE ..............................................................4-34 OTHER DIAMETERS...............................................................4-18 T6 Instant Start, T17 Instant Start, T17 Preheat ...................................................4-18 PG17 Power Groove Recessed Double Contact (1500mA)...............................4-18 T9 CIRCLINE LAMPS .............................................................4-18 See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 4-1 Fluorescent Lamps LAMP LOCATOR (NOT DRAWN TO SCALE) Mod-U-Line® T8/U6 (1'' diameter) Medium Bipin Base (G13) T9 Circline (1 1⁄8'' diameter) 4-Pin Base (G10q) T5 ( 5⁄8'' diameter) Miniature Bipin Base (G5) Mod-U-Line® T12/U3 (1 1⁄2'' diameter) Medium Bipin Base (G13) T6 ( 3⁄4'' diameter) Single Pin Base (Fa8) T8 (1'' diameter) Single Pin Base (Fa8) Mod-U-Line® T12/U6 (1 1⁄2'' diameter) Medium Bipin Base (G13) T8 (1'' diameter) Medium Bipin Base (G13) T12 (1 1⁄2'' diameter) Single Pin Base (Fa8) T8 (1'' diameter) Recessed Double Contact Base (R17d) T12 (1 1⁄2'' diameter) Medium Bipin Base (G13) T10 (1 1⁄4'' diameter) Recessed Double Contact Base (R17d) T12 (1 1⁄2'' diameter) Recessed Double Contact Base (R17d) T17 (2 1⁄8'' diameter) Mogul Bipin (G20) Power Groove® (2 1⁄8'' diameter) Recessed Double Contact Base (R17d) 4-2 See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Fluorescent Lamps BASE IDENTIFICATION Min Bipin G5 Med Bipin G13 Mog Bipin G20 Single Pin Fa8 Recessed Double Contact R17d 4-Pin G10q (Circline) INTRODUCTION GE introduced the first fluorescent lamp in 1939. Today, these lamps have become almost a universal standard in office and other lighting applications. The characteristics of fluorescent lamps vary widely according to the lamp type. In general, fluorescent lamps have the following advantages: • Low Operating Cost: Efficient, fluorescent lamps can cost significantly less to operate over their lifetime than incandescent lamps. Many common linear fluorescent lamps now have energy saving versions often designated in this catalog by Watt-Miser® (WM). • Long Life: Life ratings for fluorescent lamps range from 6000 to 30,000 hours based on the industry standard of 3 burning hours per start, except where noted. • Light Quality: GE Starcoat® T5 and T8 lamps offer higher color rendering and lumen maintenance of 95%. • Flexibility: Fluorescent lamps are available in a wide range of sizes, shapes, color performance, and wattage ratings. • Fast Starting: Rapid-Start and Instant-Start lamps typically start within 1 second of being turned on. FLUORESCENT BRAND NAME CROSS-REFERENCE GE Aquarium/Terrarium Chroma 50 CovRguard® Ecolux® Gro & ShoTM/Plant & Aquarium Kitchen and Bath ULTRA™ Mod-U-Line® Power Groove® Specification Series (SP) Specification Series (SPX) Starcoat® T5 T8 T10/1500MA /1500 Watt-Miser® Watt-Miser® Plus XL OSRAM/SYLVANIA — Design 50® — Ecologic GRO-LUX® Interior Design® (D30) Curvalume® — Designer® Series (D) Designer® “800” Series — Pentron® Octron® VHO/LT VHO SuperSaver® SuperSaver Plus® XP PHILIPS — Colortone 50 — Alto Agro-Lite Softone Pastel FL (SPEC 30) U-Bent — SPEC Series Ultralume™ — Silhouette™ TL70/TL80™ — VHO Econ-o-Watt — Advantage ATTENTION: This brand-name cross-reference chart is provided only as a quick reference. Other lamp company brand listings may only represent a near equivalent, versus an identical match to GE Lighting brands. Individual lamp manufacturer’s performance specifications and product offerings should be consulted. Lamp performance may be affected by environmental conditions, ballast type and/or other auxiliary equipment. See www.gelighting.com e-Catalog for a comprehensive cross-reference tool. See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 4-3 Fluorescent Lamps PRODUCT INFORMATION GE T5 STARCOAT® ECOLUX® LAMPS (pgs 4-7 to 4-8) GE 8' T8 LAMPS (pg 4-10) • Used in a variety of applications from indirect fixtures in commerical office buildings to warehouses and manufacturing facilities • Many combinations of wattage and length provide flexibility of fixture design and ceiling layout • Longer rated life at 30,000 hours • TCLP Compliant, lowering disposal costs where applicable (state regulations vary, consult your state EPA) • One of the most efficient fluorescent products available, up to 97 lumens per watt (LPW) • Single-pin based lamps designed to operate on Instant Start Ballast • Available in longer life (XL) versions… up to 17% longer life GE 8' T8 WATT-MISER® (XL) EXTRA LIFE LAMPS (ENERGY-SAVINGS ALTERNATIVE) (pg 4-10) • Extra-life… lasts 17% longer than standard F96T8 lamps for reduced lamp replacement and maintenance cost • Maximum energy savings… up to 3.5% less energy consumed than standard F96T8 lamps • Same light output as standard lamps • Excellent color… color enhanced SP and SPX versions • New Watt-Miser® Plus lamp reduces wattage to 54W per lamp GE T8 STARCOAT® ECOLUX® LAMPS (pgs 4-8 to 4-9 and 4-27) • More light over life – 95% lumen maintenance • Enhanced color rendering… available in 700 and 800 series • High system efficiency, relative to T12, delivers significant energy cost savings • TCLP Compliant, lowering disposal costs where applicable (state regulations vary, consult your state EPA) GE 8' T8 HIGH OUTPUT LAMPS (pg 4-10) GE STARCOAT® ECOLUX® XL EXTRA-LIFE LAMPS (pgs 4-8 to 4-9) • • • • • Same great features of the T8 Starcoat® Ecolux®… with longer life… up to 20% longer than standard T8 lamps ULTRA~T8 REPLACEMENT (ENERGY-SAVING ALTERNATIVE) GE T8 30W WATT-MISER® (pg 4-9) GE 4' T12 ECOLUX® RAPID START LAMPS • Energy-saving replacement lamp for all standard T8’s on Instant Start Ballast systems • Up to 5% savings over 32W T8 systems with maintained light levels • Operates on any standard T8 Instant Start Ballast • Also approved for use on GE UltraStart PRS Ballast • Available in XL version – 20% longer life than standard T8 lamps • All T8 Watt-Miser® lamps are TCLP Compliant and may reduce disposal costs • 80+ CRI (Color Rendering Index) (pgs 4-12 to 4-13 and 4-29) • Popular for commercial lighting • Upgrade new and existing facilities easily… change the lamp to SP/SPX color-improved lamps, available in Watt-Miser® version • TCLP Compliant, lowering disposal costs where applicable (state regulations vary, consult your state EPA) GE 4' T12 WATT-MISER® ECOLUX® ENERGY-SAVING LAMPS (WM) (pg 4-12 to 4-13 and 4-28 to 4-29) • Energy-saving replacement for all standard T12 fluorescent lamps • 12% to 20% savings in energy costs vs. standard fluorescent • TCLP Compliant, lowering disposal costs where applicable (state regulations vary, consult your state EPA) ULTRA~T12 RETROFIT (ENERGY-SAVING ALTERNATIVE) GE T8 28W ULTRAMAX® (pg 4-9) • Highly efficient T8 system utilizing the new 28W T8 lamp designed for optimal use on the GE UltraMax® ballast product family • Operates on any standard T8 Instant Start Ballast • Also approved for use on GE UltraStart PRS Ballast • 80+ CRI (Color Rendering Index) and TCLP Compliant GE T12 MOD-U-LINE® U-SHAPED LAMPS (pgs 4-14 and 4-28) • Available in standard and Watt-Miser® versions • Operate on standard or electronic Rapid Start Ballasts ULTRA~NEW CONSTRUCTION (ENERGY-SAVING ALTERNATIVE) GE T8 32W HIGH LUMEN LAMPS (HL) (pg 4-10) GE T12 HIGH OUTPUT LAMPS (pgs 4-16 to 4-17 and 4-29) • High light output and long life • Produces about 45% more initial lumens than standard lamps of the same size • Usually operated at 800mA • 5-8% more lumens than GE 32W T8 SP and SPX • 3100 initial lumens allows you to increase light levels over a standard T8 or the option to implement a de-lamp or de-fixture strategy • 20% longer life over GE F32T8 • 80+ CRI (Color Rendering Index) and TCLP Compliant GE T12 VERY HIGH OUTPUT LAMPS (pg 4-17) • Where high light levels are required – factories, warehouses, gymnasiums, open areas • Rapid Start, operated at 1500mA GE T8 MOD-U-LINE® U-SHAPED FLUORESCENT LAMPS (pg 4-11) • • • • Primarily used in 2x2 fixtures with prismatic or parabolic lenses Lower energy cost… 36% energy cost savings vs. F40T12 U-Tubes Longer lamp life than T12 Mod-U-Line® – 20,000 hours 700 and 800 Series 4-4 High system efficiency delivers 38% energy cost savings 50% longer life than T12 high output lamps Wide choice of color options Operate at 400mA See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Fluorescent Lamps PRODUCT INFORMATION (CONTINUED) COVRGUARD® SHATTER PROTECTED FLUORESCENT LAMPS (pgs 4-19 to 4-23 and 4-30) • Polycarbonate shield effectively contains shattered glass particles if lamp is broken, protecting people, food and other valuable items • UV blocking properties guard against fading and UV degradation • Available in a variety of colors for decorative and architectural applications • The covRguard® feature is available on nearly all fluorescent lamps GE COLD-TEMPERATURE LAMPS (pg 4-23 to 4-24) • Specifically designed for cold temperature applications such as freezers and coolers, display cases and outdoor areas • Available in T8, T10 and T12 versions • Rated nominal watts and initial lumens are peak values. Actual watt and lumen values may be somewhat lower in service, depending on ambient conditions. GE APPLIANCE LAMPS (pg 4-24 to 4-25) • Designed for intermittent service in appliances such as oven hoods and microwaves GE BALLASTS Energy efficiency and high performance make GE Electronic Ballasts and GE Fluorescent Lamps the perfect match for total performance. • Energy efficient – GE offers a highly efficient system to dramatically reduce electricity costs… GE UltraMax® Ballasts • Outstanding quality • Technical hotline provides specification and application support • Electromagnetic, HID, CFL, and Sign ballasts also available from GE See GE Ballast System Catalog for more information. ULTRAMAX® BALLAST (pgs 4-36 to 4-37) • The GE UltraMax® Ballast can be used with F32T8, F32T8/WM, and F28T8/ UMX lamps. The UltraMax™ Ballast is Multi-Voltage for use in 120V and 277V applications. • The UltraMax® Ballast is available in low (.77), normal (.87), and high (1.15) ballast factors. • The UltraMax® Ballast is equipped with ArcGuard Protection, UL Type CC Anti-Arc Rating, and Striation Control. GE BLACKLIGHT AND REPROGRAPHIC (pgs 4-25 and 4-30) • Blacklight (BL) lamps are commonly used in insect traps • Blacklight Blue (BLB) lamps are often used decoratively in disco lighting and theatrical applications. These lamps are produced with a special dark blue glass that filters most visible light. • The Diazo lamp emits a blue light, peaking at approximately 417nm which is used primarily in reprographic equipment GE CINEMA FLUORESCENT LAMPS (See Stage and Studio Section) • Specifically designed to be used in cinematography applications and are color corrected to match the spectral sensitivity of film • For more information and product details, visit the Stage & Studio section of this catalog GE GOLD LAMPS (pgs 4-25 to 4-26) • Effectively blocks all UV emissions below 520nm • Available in covRguard® • Used in photo-sensitive applications such as semi-conductor assembly and darkrooms GE GERMICIDAL LAMPS (pg 4-26) • Clear lamps with special UV transmitting glass • The 254nm radiation penetrates and inactivates the DNA of most micro-organisms • Used in air, water and surface purification applications See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 4-5 Fluorescent Lamps HEADINGS IN THIS CATALOG SECTION The following terms and descriptions can help you when checking Fluorescent lamp specifications and when ordering products. Within each product line, lamps are divided into families, within these families, lamps are then listed by wattage, then bulb, and then by base. There are exceptions to this ordering among the specialty lamps listed. Order Code: A measure of the visual “warmth” or “coolness” of the light from the lamp. The higher the value, the whiter or “cooler” the light appears. Mean Lumens: It is important to use this five-digit code when ording to ensure that you receive the exact product you require. Nominal Length in.: Color Temperature Kelvins (K): Lamp light output at 40% of rated lamp life. Color Rendering Index (CRI or Ra): An indication of the ability of the lamp to render object colors in a normal, natural way. The higher the number (0-100), the better the color appearance. Initial Lumens: Lamp length including base and/or pins. Lamp light output after the initial 100 hours of operation. Watts: Energy used (as defined by FTC Lamp Label Rules). To estimate energy consumption (kWh), multiply watts x hours of use and divide by 1000. Lamp burning hours to median life expectancy. Case Quantity: Bulb: ✐ Indicates that this is a lamp with high color rendering, which helps objects and persons illuminated to appear more true to life. B Number of product units packed in a case. Bulb shape followed by its size (the maximum diameter of the bulb expressed in eighths of an inch). Indicates that this is a reduced wattage option for lamps normally used in this application. Be sure to check wattage, lumens and life to determine which lamp is best suited to your needs. Description: Base: Nominal Length Order Watts in. Code Base Additional Information: The lamp’s idenification code. The type of base. Bulb Means this lamp meets Federal Minimum Efficiency Standards. Rated Life - Hours: Typical application and/or other important information. Rated Color Case Life Lumens Temp. Qty. (hours) Initial Mean K CRI Description Warning Footand notes Cautions Additional Information T8 STARCOAT® LAMPS 3' T8 ECOLUX® - TCLP COMPLIANT T8 Medium BiPin (G13) 25 36 45753 F25T8/SPX30/ECO 24 20000 2150 2040 3000 86 F 25 T8 / SPX30 / ECO Identifies as Fluorescent lamp. Identifies either the lamp‘s wattage or its length in inches. Identifies the lamp shape and the bulb diameter in eighths of an inch. Identifies the lamp finish or color. Identifies TCLP compliance. ✐ WHEN YOU DON’T KNOW THE LAMP DESCRIPTION 1. Identify bulb shape by using table on page 4-2. 2. Measure bulb diameter using ruler in Appendix section page A-1 to determine width in eighths of an inch. 3. Identify base type using table on page 4-3. 4. Find your lamp in the table containing the bulb shape, size and base. GE T8 ULTRA “ENERGY SAVING PRODUCTS” REPLACEMENT FOR T8 RETROFIT FOR T12 NEW CONSTRUCTION F32T8/SP/IS/WM/ECO F32T8/XL/SP/WM/ECO F28T8/SP/UMX/ECO F32T8/XL/SPX/HL/ECO Replace F32T8 lamps with the F32T8/WM. Up to 5% is saved instantly. For greater savings use F28T8/UMX lamps. Retrofit 4' T12 Systems with the 28W T8 UltraMax®. The ultimate in energy efficiency. Over 40% savings realized. De-lamp or use fewer fixtures in new construction. Higher light output means fewer total lamps may be needed to achieve desired footcandle levels. 5-6% higher lumens versus standard T8. 4-6 See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Fluorescent Lamps Bulb Base Nominal Length Order Watts in. Code Description Case Qty. Rated Life Color 3hr/ 12hr/ Lumens Temp. Start Start Initial Mean K CRI Warning Foot- and notes Cautions Additional Information T5 STARCOAT ECOLUX® LAMPS HIGH EFFICIENCY T5 Miniature BiPin (G5) 14 21.6 31590 46671 46673 46674 46676 21 33.4 46677 46684 46687 46688 46689 28 45.2 46704 46705 46706 46707 46708 35 57.1 46724 46727 46735 46742 46743 F14W/T5/830/ECO F14W/T5/835/ECO F14W/T5/841/ECO F14W/T5/850/ECO F14W/T5/865/ECO F21W/T5/830/ECO F21W/T5/835/ECO F21W/T5/841/ECO F21W/T5/850/ECO F21W/T5/865/ECO F28W/T5/830/ECO F28W/T5/835/ECO F28W/T5/841/ECO F28W/T5/850/ECO F28W/T5/865/ECO F35W/T5/830/ECO F35W/T5/835/ECO F35W/T5/841/ECO F35W/T5/850/ECO F35W/T5/865/ECO 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 1350 1350 1350 1300 1250 2100 2100 2100 2000 1950 2900 2900 2900 2750 2700 3650 3650 3650 3500 3400 1240 1240 1240 1190 1150 1930 1930 1930 1840 1790 2660 2660 2660 2530 2480 3350 3350 3350 3220 3120 3000 85 3500 85 4100 85 5000 85 6500 85 3000 85 3500 85 4100 85 5000 85 6500 85 3000 85 3500 85 4100 85 5000 85 6500 85 3000 85 3500 85 4100 85 5000 85 6500 85 ✐ 24 21.6 46699 46700 46701 46702 46703 39 33.4 46744 46745 46746 46747 46748 54 45.2 46759 46760 46761 46762 46763 49 57.1 46751 46752 46753 46757 46758 80 57.1 46802 46803 46804 46805 46806 F24W/T5/830/ECO F24W/T5/835/ECO F24W/T5/841/ECO F24W/T5/850/ECO F24W/T5/865/ECO F39W/T5/830/ECO F39W/T5/835/ECO F39W/T5/841/ECO F39W/T5/850/ECO F39W/T5/865/ECO F54W/T5/830/ECO F54W/T5/835/ECO F54W/T5/841/ECO F54W/T5/850/ECO F54W/T5/865/ECO F49W/T5/830/ECO F49W/T5/835/ECO F49W/T5/841/ECO F49W/T5/850/ECO F49W/T5/865/ECO F80W/T5/830/ECO F80W/T5/835/ECO F80W/T5/841/ECO F80W/T5/850/ECO F80W/T5/865/ECO 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 30000 36000 2000 2000 2000 1900 1900 3500 3500 3500 3350 3330 5000 5000 5000 4800 4750 4900 4900 4900 4700 4650 7000 7000 7000 6700 6650 1840 1840 1840 1740 1740 3220 3220 3220 3080 3060 4600 4600 4600 4410 4370 4500 4500 4500 4320 4270 6440 6440 6440 6160 6110 3000 85 3500 85 4100 85 5000 85 6500 85 3000 85 3500 85 4100 85 5000 85 6500 85 3000 85 3500 85 4100 85 5000 85 6500 85 3000 85 3500 85 4100 85 5000 85 6500 85 3000 85 3500 85 4100 85 5000 85 6500 85 ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 HIGH OUTPUT T5 Miniature BiPin (G5) ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 4-7 Fluorescent Lamps Nominal Length Order Watts in. Code Description Bulb Base Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI Warning Foot- and notes Cautions Additional Information T5 PREHEAT LAMPS 6” T5 T5 Miniature BiPin (G5) 4 6 10004 F4T5/CW 15983 F4T5/CW CARD 24 10 5000 5000 135 135 100 4100 60 100 4100 60 101 101 6 9 10032 F6T5/CW 15986 F6T5/CW CARD 10028 F6T5/D 24 10 24 5000 5000 5000 295 295 230 235 4100 60 235 4100 60 185 6500 75 101 101 101 9” T5 T5 Miniature BiPin (G5) 12” T5 T5 Miniature BiPin (G5) 8 12 10059 15987 10055 10064 25425 F8T5/CW F8T5/CW CARD F8T5/D F8T5/WW F8T5/WW/CARD 24 10 24 24 5 5000 5000 5000 5000 5000 400 400 330 410 410 320 320 265 330 330 4100 60 4100 60 6500 75 3000 52 3000 52 101 101 101 101 101 13 21 10086 49333 10089 25426 F13T5/CW F13T5/CW/CD F13T5/WW F13T5/WW/CARD 24 5 24 5 5000 5000 5000 5000 850 850 870 870 705 705 720 720 4100 60 4100 60 3000 52 3000 52 101 101 101 101 21” T5 T5 Miniature BiPin (G5) Nominal Length Order Watts in. Code Description Bulb Base Case Qty. Rated Life Color 3hr/ 12hr/ Lumens Temp. Start Start Initial Mean K CRI Warning Foot- and notes Cautions Additional Information T8 STARCOAT® LAMPS 2’ T8 ECOLUX® - TCLP COMPLIANT T8 Medium BiPin (G13) 17 24 45741 45743 45748 45742 45747 45749 F17T8/SP30/ECO F17T8/SP35/ECO F17T8/SP41/ECO F17T8/SPX30/ECO F17T8/SPX35/ECO F17T8/SPX41/ECO 24 24 24 24 24 24 20000 24000 20000 24000 20000 24000 20000 24000 20000 24000 20000 24000 1325 1325 1325 1350 1350 1350 1260 1260 1260 1280 1280 1280 3000 78 3500 78 4100 78 3000 86 3500 86 4100 86 ✐ F17T8/XL/SP30/ECO F17T8/XL/SP35/ECO F17T8/XL/SP41/ECO F17T8/XL/SPX30/ECO F17T8/XL/SPX35/ECO F17T8/XL/SPX41/ECO F17T8/XL/SPX50/ECO F17T8/XL/SPX65/ECO 24 24 24 24 24 24 24 24 24000 29000 24000 29000 24000 29000 24000 29000 24000 29000 24000 29000 24000 29000 24000 29000 1325 1325 1325 1350 1350 1350 1300 1250 1260 1260 1260 1280 1280 1280 1235 1125 3000 78 3500 78 4100 78 3000 86 3500 86 4100 86 5000 86 6500 85 ✐ 24 24 24 24 24 24 20000 24000 20000 24000 20000 24000 20000 24000 20000 24000 20000 24000 2080 2080 2080 2150 2150 2150 1970 1970 1970 2040 2040 2040 3000 78 3500 78 4100 78 3000 86 3500 86 4100 86 ✐ ✐ ✐ ✐ ✐ ✐ 18 18 18 18 18 18 101 101 101 101 101 101 18 18 18 18 18 18 18 18 101 101 101 101 101 101 101 101 18 18 18 18 18 18 101 101 101 101 101 101 2’ T8 ECOLUX® XL EXTRA-LIFE T8 Medium BiPin (G13) 3’ T8 T8 ECOLUX® 17 24 15476 15479 15480 15481 15483 15484 10415 16092 ✐ ✐ ✐ ✐ ✐ ✐ ✐ - TCLP COMPLIANT Medium BiPin (G13) 25 36 45750 45754 45756 45753 45755 45757 F25T8/SP30/ECO F25T8/SP35/ECO F25T8/SP41/ECO F25T8/SPX30/ECO F25T8/SPX35/ECO F25T8/SPX41/ECO ✐ ✐ ✐ ✐ ✐ Means this lamp meets Federal Minimum Efficiency Standards. 4-8 See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Fluorescent Lamps Nominal Length Order Watts in. Code Description Bulb Base Case Qty. Rated Life Color 3hr/ 12hr/ Lumens Temp. Start Start Initial Mean K CRI Warning Foot- and notes Cautions Additional Information T8 STARCOAT® LAMPS (CONTINUED) 3’ T8 ECOLUX® XL EXTRA-LIFE T8 Medium BiPin (G13) 25 36 15486 15487 15488 15489 15490 15491 10416 16314 F25T8/XL/SP30/ECO F25T8/XL/SP35/ECO F25T8/XL/SP41/ECO F25T8/XL/SPX30/ECO F25T8/XL/SPX35/ECO F25T8/XL/SPX41/ECO F25T8/XL/SPX50/ECO F25T8/XL/SPX65/ECO 24 24 24 24 24 24 24 24 24000 29000 24000 29000 24000 29000 24000 29000 24000 29000 24000 29000 24000 29000 24000 29000 2080 2080 2080 2150 2150 2150 2050 1950 1970 1970 1970 2040 2040 2040 1950 1755 3000 78 3500 78 4100 78 3000 86 3500 86 4100 86 5000 86 6500 85 ✐ 18 18 18 18 18 18 18 18 101 101 101 101 101 101 101 101 F32T8/SP30/ECO F32T8/SP35/ECO F32T8/SP35/ECO 12PK F32T8/SP41/ECO F32T8/SP50/ECO F32T8/SP65/ECO F32T8/SPX30/ECO F32T8/SPX35/ECO F32T8/SPX41/ECO F32T8/SPX50/ECO 36 36 12 36 36 36 36 36 36 36 20000 24000 20000 24000 20000 24000 20000 24000 20000 24000 20000 24000 20000 24000 20000 24000 20000 24000 20000 24000 2800 2800 2800 2800 2750 2700 2950 2950 2950 2800 2660 2660 2660 2660 2610 2565 2800 2800 2800 2660 3000 78 3500 78 3500 78 4100 78 5000 78 6500 78 3000 86 3500 86 4100 86 5000 86 ✐ 18 18 18 18 18 18 18 18 18 18 101 101 101 101 101 101 101 101 101 101 F32T8/XL/SP30ECO F32T8/XL/SP35ECO F32T8/XL/SP41ECO F32T8/XL/SPX30ECO F32T8/XL/SPX35ECO F32T8/XL/SPX41ECO F32T8/XL/SPX50/ECO F32T8/XL/SPX65/ECO 36 36 36 36 36 36 36 36 24000 29000 24000 29000 24000 29000 24000 29000 24000 29000 24000 29000 24000 29000 24000 29000 2800 2800 2800 2950 2950 2950 2800 2750 2660 2660 2660 2800 2800 2800 2660 2475 3000 78 3500 78 4100 78 3000 86 3500 86 4100 86 5000 86 6500 85 ✐ ✐ 18 18 18 18 18 18 18 18 101 101 101 101 101 101 101 101 36 30000 36000 2850 2675 3000 84 ✐ 36 30000 36000 2850 2675 3500 83 ✐ 36 30000 36000 2850 2675 4100 81 ✐ 18 18 18 101 101 101 ✐ ✐ ✐ ✐ ✐ ✐ ✐ 4’ T8 ECOLUX® - TCLP COMPLIANT T8 Medium BiPin (G13) 32 48 26666 26667 11873 26668 16090 16091 25611 25612 25613 42064 ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ 4’ T8 ECOLUX® XL EXTRA-LIFE T8 Medium BiPin (G13) 4’ T8 T8 ECOLUX® 32 48 27616 27617 27618 27619 27620 27621 16313 16089 ✐ ✐ ✐ ✐ ✐ ✐ SUPER LONG LIFE Medium BiPin (G13) 32 48 49702 F32T8/SXL/SP30/ECO 49778 F32T8/SXL/SP35/ECO 49779 F32T8/SXL/SP41/ECO ULTRA ENERGY SAVING T8 LAMPS 4’ T8 ECOLUX® WATT-MISER® T8 Medium BiPin (G13) 30 48 48277 48278 48279 11791 F32T8/SP30/IS/WM/ECO F32T8/SP35/IS/WM/ECO F32T8/SP41/IS/WM/ECO F32T8/SP50/IS/WM/ECO 36 36 36 36 20000 24000 20000 24000 20000 24000 20000 24000 2850 2850 2850 2750 2675 2675 2675 2585 3000 84 3500 83 4100 81 5000 80 ✐ F32T8/XL/SP30/WM/ECO F32T8/XL/SP35/WM/ECO F32T8/XL/SP41/WM/ECO F32T8/XL/SP50/WM/ECO 36 36 36 36 24000 29000 24000 29000 24000 29000 24000 29000 2800 2800 2800 2700 2625 2625 2625 2540 3000 84 3500 83 4100 81 5000 80 ✐ F28T8/SP30/UMX/ECO F28T8/SP35/UMX/ECO F28T8/SP41/UMX/ECO F28T8/SP50/UMX/ECO 36 36 36 36 18000 24000 18000 24000 18000 24000 18000 24000 2750 2750 2750 2650 2585 2585 2585 2490 3000 85 3500 85 4100 82 5000 80 ✐ 4’ T8 ECOLUX® WATT-MISER® XL EXTRA-LIFE T8 Medium BiPin (G13) 30 48 48521 48522 48523 42553 4’ T8 ECOLUX® ULTRAMAX® T8 Medium BiPin (G13) 28 48 00255 00256 00257 42554 B 1,18 B 1,18 ✐ 1,18 B 1,18 ✐ B 101 101 101 101 B 1,18 B 1,18 ✐ B 1,18 ✐ B 1,18 101 101 101 101 B 1,18 B 1,18 ✐ B 1,18 ✐ B 1,18 101 101 101 101 ✐ ✐ ✐ Means this lamp meets Federal Minimum Efficiency Standards. See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 4-9 Fluorescent Lamps Bulb Base Nominal Length Order Watts in. Code Description Case Qty. Rated Life Color 3hr/ 12hr/ Lumens Temp. start start Initial Mean K CRI Warning Foot- and notes Cautions Additional Information ULTRA ENERGY SAVING T8 LAMPS 4’ T8 ECOLUX® HIGH LUMEN T8 Medium Bipin (G13) 32 48 10327 10326 10322 42556 F32T8/XL/SPX30/HL/ECO F32T8/XL/SPX35/HL/ECO F32T8/XL/SPX41/HL/ECO F32T8/XL/SPX50/HL/ECO 36 36 36 36 24000 29000 24000 29000 24000 29000 24000 29000 3100 3100 3100 3000 2915 2915 2915 2820 3000 85 3500 85 4100 82 5000 80 ✐ B 1818 18 18 101 101 101 101 25 48 80066 F25T12/SP30/ECO 80067 F25T12/SP35/ECO 80076 F25T12/SP41/ECO 30 15000 20000 2300 2140 3000 70 30 15000 20000 2300 2140 3500 70 30 15000 20000 2300 2140 4100 70 ✐ B 1818 B 18 ✐ B 101 101 101 59 96 23407 23411 23412 23414 23415 23416 23575 F96T8/SP30 F96T8/SP35 F96T8/SP41 F96T8/SPX30 F96T8/SPX35 F96T8/SPX41 F96T8/SPX50 24 24 24 24 24 24 24 15000 20000 15000 20000 15000 20000 15000 20000 15000 20000 15000 20000 15000 20000 5800 5800 5800 5950 5950 5950 5950 5500 5500 5500 5650 5650 5650 5650 3000 78 3500 78 4100 78 3000 86 3500 86 4100 86 5000 86 ✐ 101 101 101 101 101 101 101 59 96 41889 41890 41891 41892 41893 41894 45497 F96T8/XL/SP30 F96T8/XL/SP35 F96T8/XL/SP41 F96T8/XL/SPX30 F96T8/XL/SPX35 F96T8/XL/SPX41 F96T8/XL/SPX50 24 24 24 24 24 24 24 24000 29000 24000 29000 24000 29000 24000 29000 24000 29000 24000 29000 24000 29000 5800 5800 5800 5950 5950 5950 5950 5500 5500 5500 5650 5650 5650 5650 3000 78 3500 78 4100 78 3000 86 3500 86 4100 86 5000 86 ✐ 24 24000 29000 5800 5450 3000 84 24 24000 29000 5800 5450 3500 83 24 24000 29000 5800 5450 4100 81 ✐ ✐ ✐ ✐ F25T12 ECOLUX® FOR T8 BALLASTS T12 Medium BiPin (G13) ✐ 8’ T8 LAMPS 8’ T8 T8 Single Pin (Fa8) ✐ ✐ ✐ ✐ ✐ ✐ 8’ T8 XL EXTRA-LIFE T8 Single Pin (Fa8) 8’ T8 XL EXTRA-LIFE WATT-MISER® T8 57 96 48524 F96T8/XL/SP30/WM 48525 F96T8/XL/SP35/WM 48526 F96T8/XL/SP41/WM Single Pin (Fa8) Single Pin (Fa8) Bulb Base ✐ B 11 B1 ✐ B 101 101 101 B 11 B1 ✐ B 101 101 101 ✐ ✐ ✐ ✐ ENERGY SAVING LAMPS 8’ T8 XL EXTRA-LIFE WATT-MISER® PLUS ENERGY SAVING LAMPS T8 ✐ 101 101 101 101 101 101 101 ✐ 54 96 47072 F96T8/XL/SP30/WMP 47076 F96T8/XL/SP35/WMP 47103 F96T8/XL/SP41/WMP Nominal Length Order Watts in. Code Description 24 24000 29000 5800 5450 3000 84 24 24000 29000 5800 5450 3500 83 24 24000 29000 5800 5450 4100 81 Case Rated Qty. Life ✐ ✐ Color Lumens Temp. Initial Mean K CRI Warning Foot- and notes Cautions Additional Information 8’ T8 HIGH OUTPUT 8’ T8 HIGH OUTPUT - RECESSED DOUBLE CONTACT T8 R17d 86 96 12536 12537 12538 12533 12534 12535 F96T8/SP30/HO F96T8/SP35/HO F96T8/SP41/HO F96T8/SPX35/HO F96T8/SPX41/HO F96T8/SPX50/HO 24 24 24 24 24 24 18000 18000 18000 18000 18000 18000 24 7500 8000 8000 8000 8200 8200 8200 7600 7600 7600 7800 7800 7800 3000 78 3500 78 4100 78 3500 86 4100 86 5000 86 ✐ ✐ ✐ ✐ ✐ ✐ 101 101 101 101 101 101 1 8’ T8 INSTANT START T8 Single Pin (Fa8) 50 96 10912 F96T8/CW 4050 3730 4100 60 101 Means this lamp meets Federal Minimum Efficiency Standards. 4-10 See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Fluorescent Lamps Nominal Length Order Watts in. Code Description Bulb Base Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI Warning Foot- and notes Cautions Additional Information 31 22.5 41776 F31T8/SPX30/U 41777 F31T8/SPX35/U 41778 F31T8/SPX41/U 15 20000 15 20000 15 20000 2725 2500 3000 82 2725 2500 3500 82 2725 2500 4100 82 ✐ 32 22.5 10479 23585 10480 10483 10485 10488 10489 12 12 12 12 12 12 12 20000 20000 20000 20000 20000 20000 20000 2700 2700 2700 2800 2800 2800 2660 ✐ 15 18 49489 FE15T8/XL/SPX65 24 24000 875 40 60 15950 15951 15952 22660 22661 22662 24 24 24 24 24 24 20000 20000 20000 20000 20000 20000 35 72 10829 F72T8/CW 10835 F72T8/WW 6PK 24 6 7500 7500 18 24 93311 F18T8/835PLYXLR 93317 F18T8/841PLYXLR T8 MOD-U-LINE® T8 1 5/8” SPACING T8 Medium BiPin (G13) ✐ ✐ 105 105 105 T8 6” SPACING T8 Medium BiPin (G13) F32T8/SP30/U/6 F32T8/SP35/U/6 F32T8/SP41/U/6 F32T8/SPX30/U/6 F32T8/SPX35/U/6 F32T8/SPX41/U/6 F32T8/SPX50/U/6 2565 2565 2565 2630 2630 2630 2510 3000 78 3500 78 4100 78 3000 86 3500 86 4100 86 5000 86 ✐ ✐ ✐ ✐ ✐ ✐ 105 105 105 105 105 105 105 OTHER T8 LENGTHS 18” T8 W/ STARCOAT® T8 Medium BiPin (G13) 5’ T8 W/ T8 785 6500 85 ✐ 101 Use with Electronic Ballast Only STARCOAT® Medium BiPin (G13) F40T8/SP30 F40T8/SP35 F40T8/SP41 F40T8/SPX30 F40T8/SPX35 F40T8/SPX41 3600 3600 3600 3725 3725 3725 3420 3420 3420 3350 3350 3350 3000 75 3500 75 4100 75 3000 84 3500 84 4100 84 ✐ ✐ ✐ ✐ ✐ ✐ 101 101 101 101 101 101 6’ T8 INSTANT START T8 Single Pin (Fa8) 3000 2730 4100 60 3100 2820 3000 52 101 101 Warm White 25 20000 25 20000 1350 1280 3500 85 ✐ 1350 1280 4100 85 ✐ 101 101 36 48 19991 F36T8/835PLYXLR 16856 F36T8/841PLYXLR 25 20000 25 20000 3350 3180 3500 85 ✐ 3350 3180 4100 85 ✐ 101 101 58 60 40120 F58T8/835PLYLXLR 40081 F58T8/841PLYLXLR 25 20000 25 20000 5200 4940 3500 85 ✐ 5200 4940 4000 85 ✐ 101 101 70 72 39451 F70T8/835PLYXLR 39452 F70T8/840PLYXLR 25 20000 25 20000 6300 5985 3500 85 ✐ 6300 5985 4000 85 ✐ 101 101 13 12 10098 F13T8/CW 24 7500 565 480 4100 60 101 14 15 10104 F14T8/CW 24 7500 685 580 4100 60 101 15 18 17911 19643 19644 19645 10142 24 24 24 24 24 7500 7500 7500 7500 7500 940 940 1000 1000 825 T8 POLYLUX® 2’ T8 POLYLUX® T8 Medium Bipin (G13) 4’ T8 POLYLUX® T8 Medium Bipin (G13) 6’ T8 POLYLUX® T8 Medium Bipin (G13) 7’ T8 POLYLUX® T8 Medium Bipin (G13) T8 PREHEAT 12” T8 T8 Medium BiPin (G13) 15” T8 T8 Medium BiPin (G13) 18” T8 T8 Medium BiPin (G13) F15T8/SP35 F15T8/SP41 F15T8/SPX30 F15T8/SPX35 F15T8/CW 850 850 900 900 725 3500 75 4100 72 3000 82 3500 82 4100 60 ✐ ✐ ✐ ✐ 101 101 101 101 101 See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 4-11 Fluorescent Lamps Bulb Base Nominal Length Order Watts in. Code Description Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI Warning Foot- and notes Cautions Additional Information T8 PREHEAT (CONTINUED) 18” T8 (CONTINUED) T8 Medium BiPin (G13) 4100 60 6500 75 3000 70 5000 90 3000 52 101 101 101 101 101 15 18 10143 10134 21326 13968 10147 F15T8/CW 6PK F15T8/D F15T8/KB 6PK F15T8/SUN 6PK F15T8/WW 24 24 24 24 24 7500 7500 7500 7500 7500 825 700 940 620 845 725 615 850 525 745 30 36 16323 10316 10310 22747 10318 F30T8/SPX30 F30T8/CW 6PK F30T8/D F30T8/KB 6PK F30T8/WW 24 24 24 24 24 7500 7500 7500 7500 7500 2300 2175 1850 2125 2150 2140 1980 1625 1910 1880 3000 82 ✐ 4100 60 6500 75 ✐ 3000 70 ✐ 3000 52 101 101 101 Daylight 101 Kitchen & Bath 101 Warm White 25 36 80080 80081 80065 80077 F25T12/SP30/RS/WM/ECO F25T12/SP35/RS/WM/ECO F25T12/CW/RS/WM/ECO F25T12/WW/RS/WM/ECO 24 24 24 24 18000 18000 18000 18000 2025 2025 1925 1975 1780 1780 1640 1680 3000 70 ✐ 3500 73 ✐ 4100 60 3000 52 101 101 101 101 Warm White 30 36 80087 80088 80089 80090 80083 80084 80085 80086 80091 F30T12/SP35/RS/ECO F30T12/SP41/RS/ECO F30T12/SPX30/RS/ECO F30T12/SPX35/RS/ECO F30T12/C50/RS/ECO F30T12/CW/RS/ECO F30T12/CW/RS/ECO 6PK F30T12/D/RS/ECO F30T12/WW/RS/ECO 24 24 24 24 24 24 24 24 24 18000 18000 18000 18000 18000 18000 18000 18000 18000 2350 2350 2375 2375 1650 2200 2200 1900 2275 2120 2120 2140 2140 1350 1910 1910 1650 1980 3500 73 4100 72 3000 82 3500 82 5000 90 4100 60 4100 60 6500 75 3000 52 ✐ 101 101 101 101 101 Chroma 50 101 101 101 Daylight 101 Warm White 2650 2400 3500 80 2650 2400 3500 80 2500 2200 4100 60 ✐ 2750 2750 2750 2750 2750 2750 2750 2650 2900 2900 2900 2700 2000 2650 ✐ ✐ ✐ ✐ ✐ Daylight Kitchen & Bath Sunlight Warm White 36” T8 T8 Medium BiPin (G13) T12 LAMPS 3’ T12 ECOLUX® - RAPID START 25W T12 Medium BiPin (G13) 30W T12 Medium BiPin (G13) ✐ ✐ ✐ ✐ ✐ 4’ T12 - RAPID START 32W WATT-MISER® PLUS T12 Medium BiPin (G13) 32 48 14225 F40/SP35/RS/WMP 30PK 14224 F40/SP41/RS/WMP 30PK 14221 F40/CW/RS/WMP 30PK 30 20000 30 20000 30 20000 34W WATT-MISER® ECOLUX® - TCLP COMPLIANT T12 Medium BiPin (G13) 34 48 23163 25401 23165 23486 21858 23166 25397 41563 23157 23158 23159 80095 80092 23010 F34/SP30/RS/WM/ECO 30 F34/SP30/RS/WM/ECO/UPC 30 F34/SP35/RS/WM/ECO 30 F34/SP35/WM/ECO/C 10 F34/SP35/RS/WM/ECO/UPC6P 24 F34/SP41/RS/WM/ECO 30 F34/SP41/RS/WM/ECO/UPC 30 F34/SP65/RS/WM/ECO 30 F34/SPX30/RS/WM/ECO 30 F34/SPX35/RS/WM/ECO 30 F34/SPX41/RS/WM/ECO 30 F34/SPX50/RS/WM/ECO 30 F34/C50/RS/WM/ECO 30 F34/CW/RS/WM/ECO 30 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 2475 2475 2475 2475 2475 2475 2475 2430 2610 2610 2610 2430 1720 2280 3000 70 3000 70 3500 73 3500 73 3500 73 4100 72 4100 72 6500 75 3000 82 3500 82 4100 80 5000 80 5000 90 4100 60 ✐ B 11 B1 ✐ B 101 101 101 1 B ✐ B 11 ✐ B1 ✐ B1 ✐ B1 ✐ B1 ✐ B1 ✐ B1 ✐ B1 ✐ B1 ✐ B1 ✐ B1 ✐ B1 ✐ B 101 101 101 101 101 101 101 101 101 101 101 101 101 Chroma 50 101 Means this lamp meets Federal Minimum Efficiency Standards. 4-12 See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Fluorescent Lamps Nominal Length Order Watts in. Code Description Bulb Base Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI Warning Foot- and notes Cautions Additional Information T12 LAMPS (CONTINUED) 34W WATT-MISER® ECOLUX® - TCLP COMPLIANT (CONTINUED) T12 Medium BiPin (G13) 34 48 25391 23485 80093 80094 45065 25398 F34/CW/RS/WM/ECO/UPC 30 F34/CW/RS/WM/EC0/C 10PK 10 F34/DX/RS/WM/ECO 30 F34/LW/RS/WM/ECO 30 F34/WW/RS/WM/ECO 30 F34/WW/RS/WM/ECO/UPC 30 20000 20000 20000 20000 20000 20000 2650 2650 1950 2825 2700 2700 2280 2280 1620 2430 2320 2320 4100 60 4100 60 6500 84 4200 49 3000 52 3000 52 B 11 B1 ✐ B B 11 B1 B 101 101 101 101 101 101 ✐ 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 40W ECOLUX® - TCLP COMPLIANT T12 Medium BiPin (G13) 40W ECOLUX® 40 48 80099 80186 80187 23382 80188 25400 80189 80190 80191 80199 80096 25399 13795 13969 80097 40333 21323 80098 12224 14440 14433 14441 F40/SP30/ECO F40/SP35/ECO F40/SP41/ECO F40/SP41/ECO/C F40/SP65/ECO F40/SP65/ECO/UPC F40/SPX30/ECO F40/SPX35/ECO F40/SPX41/ECO F40/SPX50/ECO F40/C50/ECO F40/C50/ECO/UPC F40/C75 30PK F40/D/ULTRA/ECO 6PK F40/DX/ECO F40/KB/ECO 2PK F40/KB/ECO 6PK F40/N/ECO F40/SUN/ECO 6PK F40/RES/ECO/SLV F40/RES/ECO/SLV 6PK F40/RES/ECO TWN 9PK 30 30 30 10 30 30 30 30 30 30 30 30 30 24 30 9 24 30 24 30 24 9 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 15000 15000 15000 3250 3200 3200 3200 3050 3050 3400 3400 3350 3200 2250 2250 1950 3050 2250 3400 3400 2100 2250 3150 3150 3150 2950 2910 2910 2910 2775 2775 3090 3090 3050 2860 1870 1870 1680 2775 1910 3090 3090 1740 1870 2860 2860 2860 3000 70 3500 73 4100 72 4100 72 6500 75 6500 75 3000 82 3500 82 4100 80 5000 80 5000 90 5000 90 7500 92 6500 75 6500 84 3000 70 3000 70 3700 90 5000 90 4100 72 4100 72 4100 72 F40/XL/SP30/ECO F40/XL/SP35/ECO F40/XL/SP41/ECO F40/XL/SPX30/ECO F40/XL/SPX35/ECO F40/XL/SPX41/ECO F40/XL/SPX50/ECO 30 30 30 30 30 30 30 24000 24000 24000 24000 24000 24000 24000 3300 3300 3300 3400 3400 3400 3350 2970 2970 2970 3060 3060 3060 3050 3000 75 3500 75 4100 73 3000 82 3500 82 4100 80 5000 80 ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ Daylight Deluxe Lite White Warm White Warm White Chroma 50 Chroma 50 Chroma 75, non-TCLP compliant Daylight Daylight Deluxe Kitchen & Bath Kitchen & Bath Natural Sunlight XL EXTRA-LIFE T12 Medium BiPin (G13) 40 48 80217 80224 80227 80230 80248 80249 80250 101 101 101 101 101 101 101 ✐ ✐ ✐ ✐ ✐ ✐ ✐ 25W ECOLUX® UTILITY SHOPLIGHT T12 Medium BiPin (G13) 25 48 14450 F48/25W/UTECO/SLV 14456 F48/25W/UTECO/TWN 14445 F48/25W/UTECO/UPC 30 12000 9 12000 30 12000 1860 1675 4100 60 1860 1675 4100 60 1860 1675 4100 60 10 10 10 101 101 101 Means this lamp meets Federal Minimum Efficiency Standards. See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 4-13 Fluorescent Lamps Bulb Base Nominal Length Order Watts in. Code Description Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI Warning Foot- and notes Cautions Additional Information T12 LAMPS (CONTINUED) T12 MOD-U-LINE® T12 3 5/8” SPACING T12 Medium BiPin (G13) 40 22.5 15259 14228 15260 14814 14813 14649 F40/SP30/U/3 F40/SP35/U/3 F40/SP41/U/3 F40/SPX30/U/3 F40/SPX35/U/3 F40/SCW/U/3 12 12 12 12 12 12 14000 14000 14000 14000 14000 14000 2925 2925 2925 3000 3000 2725 2660 2660 2660 2730 2730 2400 3000 70 3500 73 4100 72 3000 82 3500 82 4100 75 ✐ 40 22.5 15263 14227 22050 15265 14816 14648 25374 14815 14632 F40/SP30/U/6 F40/SP35/U/6 F40/SP35/U/6/UPC F40/SP41/U/6 F40/SPX30/U/6 F40/SCW/U/6 F40/SCW/U6/UPC 6PK F40/SPX35/U/6 F40/SWW/U/6 12 12 12 12 12 12 6 12 12 14000 14000 14000 14000 14000 14000 14000 14000 14000 3050 3050 3050 3050 3100 2800 2800 3100 2800 2780 2780 2780 2780 2820 2460 2460 2820 2460 3000 70 3500 73 3500 73 4100 72 3000 82 4100 75 4100 75 3500 82 3000 75 ✐ ✐ ✐ ✐ ✐ ✐ 105 105 105 105 105 105 Super Cool White T12 6” SPACING T12 Medium BiPin (G13) ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ 105 105 105 105 105 105 Super Cool White 105 Super Cool White 105 105 Super Warm White WATT-MISER® ENERGY SAVING LAMPS T12 3 5/8” SPACING WATT-MISER® T12 Medium BiPin (G13) 35 22.5 12199 F35/CW/U/3/WM 12200 F35/WW/U/3/WM T12 6” SPACING WATT-MISER® T12 Medium BiPin (G13) 35 22.5 12203 F35/CW/U/6/WM 14471 F35/CW/U/6/WM/UPC 23383 F35/CW/U6/WM/C 12207 F35/WW/U/6/WM T12 6” SPACING WATT-MISER® ECOLUX® T12 Medium BiPin (G13) 34 22.5 15622 F34/CW/U/6/WM/ECO 12 14000 12 14000 2200 2050 4100 60 2300 2100 3000 52 B 11 B 105 105 Warm White 12 12 6 12 2300 2300 2300 2350 4100 60 4100 60 4100 60 3000 52 B 11 B1 B1 B 105 105 105 105 Warm White 12 18000 2600 2235 4200 62 B1 105 24 24 24 24 24 24 24 24 7500 7500 7500 9000 9000 9000 9000 9000 1050 2000 2400 3000 3050 3050 2875 2875 4100 60 4100 60 4100 60 3500 73 ✐ 3000 82 ✐ 3500 82 ✐ 4100 60 4100 60 101 101 101 101 101 101 101 101 24 24 24 9000 9000 9000 2575 2420 3500 73 ✐ 2575 2420 4100 72 ✐ 2475 2400 2210 60 ✐ 101 101 101 15 15 15 15 15 12000 12000 12000 12000 12000 6500 6500 6500 6125 6800 101 101 101 101 101 14000 14000 14000 14000 2100 2100 2100 2150 T12 INSTANT START T12 Single Pin (Fa8) 20 30 35 40 24 36 42 48 10691 10709 10735 15262 15088 15116 10748 20461 F24T12/CW F36T12/CW F42T12/CW F48T12/SP35 F48T12/SPX30 F48T12/SPX35 F48T12/CW F48T12/CW/UPC 6PK 900 1800 2210 2820 2870 2870 2650 2650 WATT-MISER® ENERGY SAVING LAMPS T12 Single Pin (Fa8) 30 48 14319 F48T12/SP35/WM 13048 F48T12/SP41/WM 44967 F48T12/CW/WM B 11 B1 B 8’ T12 INSTANT START 8’ INSTANT START STANDARD T12 Single Pin (Fa8) 75 96 15357 14067 15358 12127 15110 F96T12/SP30 15PK F96T12/SP35 15PK F96T12/SP41 15PK F96T12/SP65 F96T12/SPX30 15PK 6110 6110 6110 5760 6390 3000 70 3500 73 4100 72 6500 75 3000 82 ✐ ✐ ✐ ✐ ✐ Means this lamp meets Federal Minimum Efficiency Standards. 4-14 See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Fluorescent Lamps Bulb Base Nominal Length Order Watts in. Code Description Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI Warning Foot- and notes Cautions Additional Information T12 LAMPS (CONTINUED) 8’ T12 INSTANT START (CONTINUED) 8’ INSTANT START STANDARD (CONTINUED) T12 Single Pin (Fa8) 75 96 15101 15335 23466 14652 13725 13752 25387 F96T12/SPX35 15PK F96T12/SPX41 15PK F96T12/SPX50 15PK F96T12/DX F96T12/N 15PK F96T12/C50 F96T12/C50/UPC 15 15 15 15 15 15 15 12000 12000 12000 12000 12000 12000 12000 6800 6800 6250 4500 4250 4600 4600 6390 6390 5880 4050 3740 4050 4050 3500 82 ✐ 4100 80 ✐ 5000 80 ✐ 6500 84 ✐ 3700 90 ✐ 5000 90 ✐ 5000 90 ✐ 101 101 101 101 101 101 101 15 15 15 15 15000 15000 15000 15000 6700 6700 6900 6425 6180 6180 6370 5930 3500 75 4100 73 4100 80 5000 80 ✐ ✐ 101 101 101 101 15 15 15 10 15 15 10 15 15 15 15 15 10 15 15 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 5700 5700 5700 5700 5700 5700 5500 5100 6000 6000 4000 5500 5500 5800 5700 5360 5360 5360 5360 5360 5360 5060 4800 5640 5640 3520 5060 5060 5340 5240 3000 70 3500 73 3500 73 3500 73 4100 72 4100 72 4100 60 6500 75 3000 82 3500 82 5000 90 4100 60 4100 60 4200 49 3000 52 ✐ B 11 B1 ✐ B1 ✐ B1 ✐ B1 ✐ B1 ✐ B1 ✐ B1 ✐ B1 ✐ B1 ✐ B1 B1 B1 B1 B 101 101 101 101 101 101 101 101 101 101 101 Chroma 50 101 101 101 Lite White 101 Warm White 15 15000 15 15000 5900 5480 3500 75 5900 5480 4100 73 ✐ 15 15 15 15 15 15 5700 5700 5100 6000 6000 5500 ✐ Daylight Deluxe Natural Chroma 50 Chroma 50 8’ INSTANT START XL EXTRA-LIFE T12 Single Pin (Fa8) 75 96 23576 11661 11664 11665 F96T12/XL/SP35 F96T12/XL/SP41 F96T12/XL/SPX41 F96T12/XL/SPX50 ✐ ✐ WATT-MISER® ENERGY SAVING LAMPS 8’ INSTANT START WATT-MISER® T12 Single Pin (Fa8) 60 96 14201 F96T12/SP30/WM 15PK 13849 F96T12/SP35/WM 15PK 21856 F96T12/SP35/WM/UPC 11217 F96T12/SP35/WM/C 10PK 13758 F96T12/SP41/WM 15PK 25395 F96T12/SP41/WM/UPC 25171 F96T12/UTCW/EE/C 12128 F96T12/SP65/WM 14629 F96T12/SPX30/WM 15PK 14630 F96T12/SPX35/WM 15PK 13756 F96T12/C50/WM 15PK 13729 F96T12/CW/WM15PK 21713 F96T12/CW/WM/UPC 10PK 13742 F96T12/LW/WM 15PK 13736 F96T12/WW/WM 15PK 8’ INSTANT START WATT-MISER® XL EXTRA-LIFE T12 Single Pin (Fa8) 60 96 12406 F96T12/XL/SP35/WM 12408 F96T12/XL/SP41/WM 8’ INSTANT START WATT-MISER® ECOLUX® T12 Single Pin (Fa8) 60 96 27233 F96T12/SP35/WM/ECO 27235 F96T12/SP41/WM/ECO 40373 F96T12/SP65/WM/ECO 27237 F96T12/SPX30/WM/ECO 27238 F96T12/SPX35/WM/ECO 27186 F96T12/CW/WM/ECO 12000 12000 12000 12000 12000 12000 5360 5360 4800 5640 5640 5060 3500 73 4100 72 6500 75 3000 82 3500 82 4100 60 ✐ ✐ B 11 B 101 101 B 11 B1 ✐ B1 ✐ B1 ✐ B B1 101 101 101 101 101 101 ✐ T12 OTHER LENGTHS 5’ T12 INSTANT START T12 Single Pin (Fa8) 50 60 23073 F60T12/CW 15PK 23076 F60T12/D 15PK 15 12000 15 12000 3600 3310 4100 60 3000 2760 6500 75 ✐ 101 101 Daylight 15 10000 15 10000 3850 3540 4100 60 3300 3040 6500 75 ✐ 101 101 Daylight 64” T12 INSTANT START T12 Single Pin (Fa8) 50 64 23082 F64T12/CW15PK 23085 F64T12/D 15PK Means this lamp meets Federal Minimum Efficiency Standards. See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 4-15 Fluorescent Lamps Nominal Length Order Watts in. Code Description Bulb Base Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI Warning Foot- and notes Cautions Additional Information T12 LAMPS (CONTINUED) T12 OTHER LENGTHS (CONTINUED) 6’ T12 INSTANT START® T12 Single Pin (Fa8) 7’ T12 INSTANT 55 72 15286 15097 15117 15098 13743 23385 12525 13748 F72T12/SP35 15PK F72T12/SP41 F72T12SPX30 15PK F72T12/SPX35 15PK F72T12/CW 15PK F72T12/CW/C F72T12/CW/UPC 10PK F72T12/D 15PK 15 15 15 15 15 10 10 15 12000 12000 12000 12000 12000 12000 12000 12000 4700 4700 4800 4800 4500 4500 4500 3800 4420 4420 4510 4510 4140 4140 4140 3500 3500 73 4100 72 3000 82 3500 82 4100 60 4100 60 4100 60 6500 75 ✐ ✐ ✐ ✐ ✐ 101 101 101 101 101 101 101 101 Daylight START® T12 Single Pin (Fa8) 65 84 13764 F84T12/CW 15PK 15 12000 5300 4880 4100 60 101 T12 HIGH OUTPUT (800mA) RAPID START RECESSED DOUBLE CONTACT 18” HIGH OUTPUT T12 R17d 30 18 10204 F18T12/CW/HO 24 9000 1000 750 4100 60 101 35 24 10261 F24T12/CW/HO 10275 F24T12/D/HO 24 24 9000 9000 1620 1345 4100 60 1400 1160 6500 74 ✐ 101 101 Daylight 40 30 33707 F30T12/CW/HO 24 9000 2250 1950 4100 60 101 45 36 10374 F36T12/CW/HO 10380 F36T12/D/HO 10388 F36T12/SGN/HO 24 24 24 9000 9000 9000 2800 2440 4100 60 2350 2040 6500 75 ✐ 2150 1830 5400 82 ✐ 101 101 101 55 42 10559 F42T12/CW/HO 10560 F42T12/D/HO 10562 F42T12/SGN/HO 24 24 24 9000 9000 9000 3200 2790 4100 60 2900 2520 6500 74 ✐ 2600 2215 5400 82 ✐ 101 101 Daylight 101 Sign White 60 48 15359 15360 15361 15115 10773 27313 10778 10573 24 24 24 24 24 24 24 24 12000 12000 12000 12000 12000 12000 12000 12000 4250 4250 4250 4350 3825 3825 3400 3100 101 101 101 101 101 101 101 Daylight 101 Sign White 2’ HIGH OUTPUT T12 R17d 30” HIGH OUTPUT T12 R17d 3’ HIGH OUTPUT T12 R17d 42” HIGH OUTPUT T12 R17d 4’ HIGH OUTPUT T12 R17d F48T12/SP30/HO F48T12/SP35/HO F48T12/SP41/HO F48T12/SPX35/HO F48T12/CW/HO F48T12/CW/HO/UPC F48T12/D/HO F48T12/SGN/HO 3830 3830 3830 3920 3320 3320 2960 2640 3000 70 3500 73 4100 72 3500 82 4100 60 4100 60 6500 75 5400 80 ✐ ✐ ✐ ✐ ✐ ✐ 4’ HIGH OUTPUT WATT-MISER® ENERGY SAVING LAMPS T12 R17d 55 48 15342 F48T12/SP35/HO/WM 11179 F48T12/LW/HO/WM 24 12000 24 12000 3850 3465 3500 73 ✐ 3900 3390 4200 49 B 11 B 101 101 Lite White 75 60 23075 F60T12/CW/HO 15PK 23077 F60T12/D/HO 15PK 23081 F60T12/SGN/HO 15PK 15 12000 15 12000 15 12000 5150 4480 4100 60 4400 3830 6500 75 ✐ 4000 3400 5400 82 ✐ 101 101 Daylight 101 Sign White 80 64 23083 F64T12/CW/HO 15PK 23087 F64T12/D/HO 15PK 23089 F64T12/SGN/HO15PK 15 12000 15 12000 15 12000 5600 4870 4100 60 4750 4130 6500 75 ✐ 4300 3660 5400 82 ✐ 101 101 Daylight 101 Sign White 5’ HIGH OUTPUT T12 R17d 64” HIGH OUTPUT T12 R17d 4-16 See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Fluorescent Lamps Bulb Base Nominal Length Order Watts in. Code Description Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI Warning Foot- and notes Cautions Additional Information T12 LAMPS (CONTINUED) T12 HIGH OUTPUT (800mA) RAPID START RECESSED DOUBLE CONTACT (CONTINUED) 6’ HIGH OUTPUT T12 R17d 85 72 15343 15347 15348 15137 15351 13697 13699 12527 13701 13702 F72T12/SP30/HO 15PK F72T12/SP35/HO 15PK F72T12/SP41/HO 15PK F72T12/SPX30/HO 15PK F72T12/SPX35/HO 15PK F72T12/CW/HO 15PK F72T12/D/HO 15PK F72T12/N/HO F72T12/SGN/HO 15PK F72T12/WW/HO 15PK 15 15 15 15 15 15 15 10 15 15 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 6650 6650 6650 6800 6800 6350 5350 4300 4900 6550 5990 5990 5990 6120 6120 5520 4650 3610 4170 5700 3000 70 3500 73 4100 72 3000 82 3500 82 4100 60 6500 75 3700 90 5400 82 3000 52 101 101 101 101 101 101 101 101 101 101 ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ Daylight Natural Sign White Warm White 7’ HIGH OUTPUT T12 R17d 100 84 13766 F84T12/CW/HO 15PK 13767 F84T12/D/HO 15PK 13768 F84T12/SGN/HO 15PK 15 12000 15 12000 15 12000 7700 6700 4100 60 6500 5660 6500 75 ✐ 6000 5100 5400 82 ✐ 101 101 Daylight 101 Sign White 110 96 15362 15363 15364 12130 15119 15352 23070 13707 14653 13709 15 15 15 15 15 15 15 15 15 15 9200 9200 9200 8900 9350 9350 9350 6750 6600 6200 8280 8280 8280 8010 8420 8420 8420 5670 5610 5210 3000 70 ✐ 3500 73 ✐ 4100 72 ✐ 6500 75 ✐ 3000 82 ✐ 3500 82 ✐ 4100 80 ✐ 5000 90 ✐ 6500 84 ✐ 3700 90 ✐ 101 101 101 101 101 101 101 101 Chroma 50 101 Daylight Deluxe 101 Natural 8350 8350 7700 8500 8500 8500 8000 8000 8500 8200 7520 7520 6930 7650 7650 7650 6960 6960 7900 7130 3500 73 4100 72 6500 75 3000 82 3500 82 4100 80 4100 60 4100 60 4200 49 3000 52 ✐ 101 101 101 101 101 101 101 101 101 Lite White 101 Warm White 8000 6480 4100 60 ✐ 8’ HIGH OUTPUT T12 R17d F96T12/SP30/HO 15PK F96T12/SP35/HO 15PK F96T12/SP41/HO 15PK F96T12/SP65/HO F96T12/SPX30/HO 15PK F96T12/SPX35/HO 15PK F96T12/SPX41/HO 15PK F96T12/C50/HO 15PK F96T12/DX/HO F96T12/N/HO 15PK 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 8’ HIGH OUTPUT WATT-MISER® ENERGY SAVING LAMPS T12 R17d 95 96 14069 13721 12131 15120 15122 23069 13716 21714 13720 13719 F96T12/SP35/HO/WM F96T12/SP41/HO/WM 15PK F96T12/SP65/HO/WM F96T12/SPX30/HO/WM F96T12/SPX35/HO/WM F96T12/SPX41/HO/WM F96T12/CW/HO/WM 15PK F96T12/CW/HO/WM/UPC F96T12/LW/HO/WM F96T12/WW/HO/WM 15PK 15 15 15 15 15 15 15 15 15 15 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 8’ HIGH OUTPUT WATT-MISER ECOLUX® T12 R17d 95 96 16495 F96T12/CW/HO/WM/ECO 15 12000 B 11 B1 ✐ B1 ✐ B1 ✐ B1 ✐ B1 ✐ B B 1 1 1 B1 101 T12 VERY HIGH OUTPUT (1500mA) RECESSED DOUBLE CONTACT T12 R17d 110 48 10751 F48T12/CW/1500 165 72 13760 F72T12/CW/1500 15PK 185 96 13789 F96T12/CW/1500/WM 15PK 13790 F96T12/LW/1500/WM 15PK 215 96 13781 F96T12/CW/1500 15PK 13783 F96T12/D/1500 15PK 13785 F96T12/WW/1500 15PK 24 15 15 15 15 15 15 10000 10000 9000 9000 10000 10000 10000 6200 9000 12500 13250 13500 11500 14000 4030 6300 9380 9940 10125 8630 10500 4100 60 4100 60 4100 60 4200 49 4100 60 6500 74 ✐ 3000 52 B B 4 4 4 4 4 4 4 101 101 101 101 Lite White 101 101 Daylight 101 Means this lamp meets Federal Minimum Efficiency Standards. See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 4-17 Fluorescent Lamps Nominal Length Order Watts in. Code Description Bulb Base Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI Warning Foot- and notes Cautions Additional Information T12 LAMPS (CONTINUED) T12 PREHEAT 15” T12 Medium BiPin (G13) 14 15 10116 F14T12/CW 10117 F14T12/CW 6PK 22979 F14T12/KB 6PK 24 24 24 9000 9000 9000 650 650 700 550 4100 60 550 4100 60 650 3000 70 ✐ 101 Preheat 101 Preheat 104 Preheat, Kitchen & Bath 15 18 10183 F15T12/CW 6PK 22745 F15T12/KB 6PK 10185 F15T12/WW 24 24 24 9000 9000 9000 760 785 780 685 4100 60 730 3000 70 ✐ 700 3000 52 10 Preheat 104 Preheat, Kitchen & Bath 101 Preheat 20 24 14423 15353 15354 38114 10213 10214 10205 25575 21325 14419 10217 25577 F20T12/SP35 F20T12/SP41 F20T12/SPX35 F20T12/C50 F20T12/CW F20T12/CW 6PK F20T12/D F20T12/D/UPC F20T12/KB 6PK F20T12/SUN 6PK F20T12/WW F20T12/WW-UPC 24 24 24 24 24 24 24 24 24 24 24 24 9000 9000 9000 9000 9000 9000 9000 9000 9000 9000 9000 9000 1275 1275 1300 875 1200 1200 1025 1025 1275 875 1250 1250 1200 1200 1220 790 1150 1150 945 945 1200 790 1150 1150 3500 73 4100 72 3500 82 5000 90 4100 60 4100 60 6500 75 6500 75 3000 70 5000 90 3000 52 3000 52 25 42 12221 10720 10721 40 64 12223 10805 10807 F42T6/SP35 F42T6/CW F42T6/WW F64T6/SP35 F64T6/CW F64T6/WW 24 24 24 24 24 24 7500 7500 7500 7500 7500 7500 1830 1750 1825 2930 2800 2900 1700 1580 1640 2720 2520 2610 3500 73 ✐ 4100 60 3000 52 3500 73 ✐ 4100 60 3000 52 40 60 10575 F40T17/CW/IS 12 7500 2850 2620 4100 60 3 82 60 43443 F90T17/CW/WM 90 60 10643 F90T17/CW 12 12 9000 9000 5750 5060 4100 60 6000 5280 4100 60 B 44 101 101 B 44 101 101 101 Daylight 18” T12 Medium BiPin (G13) 24” T12 Medium BiPin (G13) 101 101 101 101 101 101 101 101 104 101 101 101 ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ Preheat Preheat Preheat Preheat, Chroma 50 Preheat Preheat Preheat, Daylight Preheat, Daylight Preheat, Kitchen & Bath Preheat, Sunlight Preheat, Warm White Preheat, Warm White OTHER DIAMETERS T6 INSTANT START T6 Single Pin (Fa8) 101 101 101 Warm White 101 101 101 Warm White T17 INSTANT START T17 Mogul BiPin (G20) 101 Use only w/ instant start ballasts T17 PREHEAT T17 Mogul BiPin (G20) PG17 POWER GROOVE RECESSED DOUBLE CONTACT (1500mA) PG17 R17d T9 CIRCLINE® T9 4 Pin (G10q) 4-18 185 96 42666 F96PG17/CW/WM 215 96 11009 F96PG17/CW 11018 F96PG17/D 8 12000 8 10000 8 10000 12700 9900 4100 60 14000 10915 4100 60 12100 9440 6500 74 ✐ 4 LAMPS 20 6.5 42732 22 8.25 33774 11026 11084 32 12 33890 11039 11085 40 16 33893 11052 FC6T9/CW FC8T9/CW FC8T9/D FC8T9/KB FC12T9/CW FC12T9/D FC12T9/KB FC16T9/CW FC16T9/D 12 12 12 6 12 12 6 12 12 12000 12000 12000 12000 12000 12000 12000 12000 12000 800 1100 925 1400 1950 1675 2400 2700 2250 560 825 690 1120 1460 1260 1920 2030 1690 4100 60 4100 60 6500 75 3000 82 4100 60 6500 75 3000 82 4100 60 6500 75 ✐ ✐ ✐ ✐ ✐ 101 101 101 104 101 101 104 101 101 Daylight Kitchen & Bath Daylight Kitchen & Bath Daylight See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Fluorescent Lamps Bulb Base Nominal Length Order Watts in. Code Description Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI Warning Foot- and notes Cautions Additional Information SPECIAL APPLICATION LAMPS COVRGUARD® SHATTER PROTECTED T5 T5 HIGH EFFICIENCY T5 Miniature BiPin (G5) T5 HIGH OUTPUT T5 Miniature BiPin (G5) T5 PREHEAT LAMPS T5 Miniature BiPin (G5) 28 45.2 81546 81547 81548 81549 81550 F28T5/830ECO/CVG F28T5/835ECO/CVG F28T5/841ECO/CVG F28T5/850ECO/CVG F28T5/865ECO/CVG 40 40 40 40 40 20000 20000 20000 20000 20000 2840 2840 2840 2840 2840 2670 2670 2670 2670 2670 3000 85 3500 85 4100 85 5000 85 6500 85 ✐ 11,13 11,13 11,13 11,13 11,13 103 103 103 103 103 54 45.2 48433 48436 48458 80311 48469 F54T5/830ECO/HO/CVG F54T5/835ECO/HO/CVG F54T5/841ECO/HO/CVG F54T5/850ECO/HO/CVG F54T5/865ECO/HO/CVG 40 40 40 40 40 30000 30000 30000 30000 30000 4850 4850 4850 4650 4600 4560 4560 4560 4560 4320 3000 85 3500 85 4100 85 5000 85 6500 85 ✐ 11,13 11,13 11,13 11,13 11,13 103 103 103 103 103 4 6 41435 6 9 41106 8 12 41107 13 21 41108 F4T5/CW/CVG F6T5/CW/CVG F8T5/CW/CVG F13T5/CW/CVG 24 24 24 24 5000 5000 5000 5000 130 285 385 820 95 225 310 680 4100 60 4100 60 4100 60 4100 60 11,13 11,13 11,13 11,13 103 103 103 103 F42T6/CW/CVG F42T6/SP35/CVG F42T6/WW/CVG F64T6/CW/CVG F64T6/SP35/CVG 24 24 24 24 24 7500 7500 7500 7500 7500 1690 1770 1770 2710 2840 1530 1640 1590 2440 2630 4100 60 3500 73 ✐ 3000 52 4100 60 3500 73 ✐ 11,13 11,13 11,13 11,13 11,13 103 103 103 Warm White 103 103 F17T8/SP30/ECO/CVG F17T8/SP35/ECO/CVG F17T8/SP41/ECO/CVG F17T8/SPX35/ECO/CVG F17T8/SPX41/ECO/CVG 24 24 24 24 24 20000 20000 20000 20000 20000 1280 1280 1280 1310 1310 1220 1220 1220 1242 1242 3000 78 3500 78 4100 78 3500 86 4100 86 ✐ 11,13,18 11,13,18 11,13,18 11,13,18 11,13,18 103 103 103 103 103 F25T8/SP30/ECO/CVG F25T8/SP35/ECO/CVG F25T8/SP41/ECO/CVG F25T8/SPX30/ECOCVG F25T8/SPX35/ECOCVG F25T8/SPX41/ECOCVG 24 24 24 24 24 24 20000 20000 20000 20000 20000 20000 2020 2020 2020 2080 2080 2080 1920 1920 1920 1970 1970 1970 3000 78 3500 78 4100 78 3000 86 3500 86 4100 86 ✐ 11,13,18 11,13,18 11,13,18 11,13,18 11,13,18 11,13,18 103 103 103 103 103 103 ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ T6 T6 INSTANT START LAMPS T6 Single Pin (Fa8) 25 42 41140 41142 41141 40 64 46422 41143 T8 ECOLUX® W/ STARCOAT 2’ T8 ECOLUX® W/ STARCOAT T8 Medium BiPin (G13) 17 24 47417 15974 15877 15975 15976 3’ T8 ECOLUX® W/ STARCOAT T8 Medium BiPin (G13) 25 36 15978 15981 15984 15989 15990 15991 ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ Means this lamp meets Federal Minimum Efficiency Standards. See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 4-19 Fluorescent Lamps Bulb Base Nominal Length Order Watts in. Code Description Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI Warning Foot- and notes Cautions Additional Information SPECIAL APPLICATION LAMPS (CONTINUED) COVRGUARD® SHATTER PROTECTED (CONTINUED) T8 ECOLUX® W/ STARCOAT® (CONTINUED) 4’ T8 (48”) ECOLUX® W/ STARCOAT® T8 Medium BiPin (G13) 32 48 40803 F32T8/SP30/ECO/CVG 40804 F32T8/SP35/ECO/CVG 40812 F32T8/SP41/ECO/CVG 18366 F32T8/SP50/ECO/CVG 18368 F32T8/SP65/ECO/CVG 41125 F32T8/SPX30/ECO/CVG 41126 F32T8/SPX35/ECO/CVG 41127 F32T8/SPX41/ECO/CVG 15971 F32T8/SPX50/ECO/CVG 4’ T8 ECOLUX® XL EXTRA-LIFE W/ STARCOAT® T8 Medium BiPin (G13) 32 48 15972 F32T8/XL/SPX30ECO/CVG 15973 F32T8/XL/SPX35ECO/CVG 18369 F32T8/XL/SPX41ECO/CVG 23746 F32T8/XL/SPX50ECO/CVG ® 4’ T8 ECOLUX SUPER LONG LIFE W/ STARCOAT® T8 Medium BiPin (G13) 32 48 14560 F32T8/SXL/SP35/ECO/CVG 14551 F32T8/SXL/SP41/ECO/CVG 36 36 36 36 36 36 36 36 36 20000 20000 20000 20000 20000 20000 20000 20000 20000 2715 2715 2715 2665 2620 2860 2860 2860 2715 2580 2580 2580 2530 2490 2710 2710 2710 2580 3000 78 3500 78 4100 78 5000 78 6500 78 3000 86 3500 86 4100 86 5000 86 ✐ 36 36 36 36 20000 20000 20000 20000 2860 2860 2860 2860 2715 2715 2715 2715 3000 86 3500 86 4100 86 4100 86 ✐ 2765 2595 3500 83 2765 2595 4100 81 ✐ 20000 20000 20000 20000 2790 2765 2740 2740 2620 2595 2570 2570 3000 84 3500 83 4100 81 4100 81 ✐ 24000 24000 24000 24000 2740 2715 2690 2690 2570 2545 2520 2520 3000 84 3500 83 4100 81 4100 81 ✐ 24000 24000 24000 24000 3005 3005 3005 3005 2825 2825 2825 2825 4100 82 3500 85 3000 85 4100 82 ✐ 20000 20000 20000 20000 20000 20000 2640 2640 2640 2740 2740 2740 2510 2510 2510 2575 2575 2575 3000 78 3500 78 4100 78 3000 86 3500 86 4100 86 ✐ 36 30000 36 30000 ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ 1,13,18 1,13,18 1,13,18 1,13,18 1,13,18 1,13,18 1,13,18 1,13,18 1,13,18 103 103 103 103 103 103 103 103 103 1,13,18 1,13,18 1,13,18 1,13,18 103 103 103 103 1,13,18 103 1,13,18 103 ULTRA ENERGY SAVING T8 LAMPS W/ COVRGUARD® 4’ T8 ECOLUX® WATT-MISER® W/ STARCOAT® T8 Medium BiPin (G13) 32 48 40286 F32T8/SP30/IS/WM/ECO/CVG 36 40299 F32T8/SP35/IS/WM/ECO/CVG 36 40309 F32T8/SP41/IS/WM/ECO/CVG 36 47422 F32T8/SP50/IS/WM/ECO/CVG 36 4’ T8 ECOLUX® WATT-MISER® XL EXTRA-LIFE W/ STARCOAT® T8 Medium BiPin (G13) 32 48 10023 F32T8/XL/SP30/WM/ECOCVG 36 40297 F32T8/XL/SP35/WM/ECOCVG 36 40310 F32T8/XL/SP41/WM/ECOCVG 36 47423 F32T8/XL/SP50/WM/ECOCVG 36 4’ T8 ECOLUX® HIGH LUMEN XL EXTRA-LIFE W/ STARCOAT® T8 Medium BiPin (G13) 32 48 00267 F32T8/XL/SPX30/HL/ECO/CVG 36 00268 F32T8/XL/SPX35/HL/ECO/CVG 36 00269 F32T8/XL/SPX41/HL/ECO/CVG 36 80497 F32T8/XL/SPX50/HL/ECO/CVG 36 T8 MOD-U-LINE® 6” SPACING T8 Medium BiPin (G13) 32 22.5 23655 F32T8/SP30/U6/CVG 12 23656 F32T8/SP35/U6/CVG 12 23657 F32T8/SP41/U6/CVG 12 23658 F32T8/SPX30/U6/CVG 12 23659 F32T8/SPX35/U6/CVG 12 23660 F32T8/SPX41/U6/CVG 12 5’ T8 W/ 103 B 1,11,13,18 1,11,13,18 103 B 1,11,13,18 103 ✐ B 1,11,13,18 103 ✐ B ✐ 103 B 1,11,13,18 1,11,13,18 103 B 1,11,13,18 103 ✐ B 1,11,13,18 103 ✐ B ✐ 1,13,18 1,13,18 1,13,18 1,13,18 103 103 103 103 ✐ 11,13 11,13 11,13 11,13 11,13 11,13 103 103 103 103 103 103 3490 3140 3500 75 ✐ 3610 3240 3500 84 ✐ 3610 3250 4100 80 ✐ 11,13 11,13 11,13 103 103 103 ✐ ✐ ✐ ✐ ✐ ✐ ✐ STARCOAT® 5’ T8 (60”) W/ STARCOAT® T8 Medium BiPin (G13) 40 60 41130 F40T8/SP35/CVG 41131 F40T8/SPX35/CVG 47351 F40T8/SPX41/CVG 24 20000 24 20000 24 20000 Means this lamp meets Federal Minimum Efficiency Standards. 4-20 See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Fluorescent Lamps Bulb Base Nominal Length Order Watts in. Code Description Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI Warning Foot- and notes Cautions Additional Information SPECIAL APPLICATION LAMPS (CONTINUED) COVRGUARD® SHATTER PROTECTED (CONTINUED) T8 INSTANT START W/ STARCOAT® 6’ T8 (72”) INSTANT START T8 Single Pin (Fa8) 35 72 41149 F72T8/CW/CVG 8’ T8 (96”) INSTANT START W/ STARCOAT® T8 Single Pin (Fa8) 59 96 40094 F96T8/SP30/CVG 40095 F96T8/SP35/CVG 40096 F96T8/SP41/CVG 40099 F96T8/SPX30CVG 40105 F96T8/SPX35/CVG 40106 F96T8/SPX41/CVG 24 7500 24 24 24 24 24 24 15000 15000 15000 15000 15000 15000 8’ T8 HIGH OUTPUT LAMPS RECESSED DOUBLE CONTACT W/ T8 R17d 2910 2640 4100 60 5620 5620 5620 5770 5770 5770 5330 5330 5330 5480 5480 5480 3000 75 3500 75 4100 75 3000 84 3500 84 4100 80 ✐ ✐ ✐ ✐ ✐ ✐ 11,13 103 11,13 11,13 11,13 11,13 11,13 11,13 103 103 103 103 103 103 STARCOAT® 86 96 40107 F96T8/SP35/HO/CVG 40108 F96T8/SP41/HO/CVG 24 18000 24 18000 7760 6980 3500 75 ✐ 7760 6980 4100 75 ✐ 11,12,13 103 11,12,13 103 13 12 41109 15 18 41110 46627 46216 41111 18 24 41117 19 28 41121 30 36 41122 46206 24 24 24 24 24 6 6 24 24 7500 7500 7500 7500 7500 7500 7500 7500 7500 545 800 910 910 970 1180 1300 2100 2230 465 700 825 825 870 1000 1110 1920 2070 4100 60 4100 60 3000 70 3500 75 3500 82 4100 60 4100 60 4100 60 3000 82 ✐ 11,13 11,13 11,13 11,13 11,13 11,13 11,13 11,13 11,13 103 103 103 103 103 103 103 103 103 30 36 80486 F30T12/CW/RS/ECO/CVG 24 80987 F30T12/SPX30/RS/ECO/CVG 24 80487 F30T12/SPX35/RS/ECO/CVG 24 80986 F30T12/SP35/ECO/CVG 24 4’ T12 ECOLUX® RAPID START LAMPS (48”) T12 Medium BiPin (G13) 40 48 80495 F40/CW/ECO/CVG 30 80992 F40/CW/ECO/CVG 6PACK 6 80995 F40/KB/ECO/CVG/UPC 24 80988 F40T12/SP30/ECO/CVG 30 80989 F40T12/SP35/ECO/CVG 30 80990 F40/SP65/ECO/CVG 30 80493 F40/SPX30/ECO/CVG 30 80494 F40/SPX35/ECO/CVG 30 80991 F40/SPX41/ECO/CVG 30 80993 F40/D/ECO/CVG 30 80994 F40/DX/ECO/CVG 30 80996 F40/N/ECO/CVG 30 80496 F40/C50/ECO/CVG 30 41133 F40/C75/CVG 30 18000 18000 18000 18000 2130 2300 2300 2280 1850 2070 2070 2050 4100 60 3000 82 ✐ 3500 86 ✐ 3500 73 ✐ 11,13 11,13 11,13 11,13 103 103 103 103 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 2950 2950 3290 3150 3100 2950 3290 3290 3240 2470 2180 2030 2180 1890 2600 2600 2990 2860 2820 2690 2990 2990 2950 2170 1850 1680 1810 1630 4100 60 4100 60 3000 82 3000 70 3500 73 6500 75 3000 82 3500 82 4100 80 6250 75 6500 84 3700 90 5000 90 7500 92 11,13 11,13 11,13 11,13 11,13 11,13 11,13 11,13 11,13 11,13 11,13 11,13 11,13 11,13 103 103 103 103 103 103 103 103 103 103 103 103 103 103 T8 PREHEAT LAMPS T8 Medium BiPin (G13) F13T8/CW/CVG F15T8/CW/CVG F15T8/KB/CVG/UPC F15T8/SP35/CVG F15T8/SPX35/CVG F24T8/CW/4/CVG F28T8/CW/4/CVG F30T8/CW/CVG F30T8/SPX30/CVG ✐ ✐ ✐ Preheat Preheat Preheat, Kitchen & Bath Preheat Preheat Preheat Preheat Preheat Preheat T12 RAPID START LAMPS 3’ ECOLUX® T12 (36”) T12 Medium BiPin (G13) ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ Kitchen & Bath Daylight Daylight Deluxe Natural Chroma 50 Chroma 75, non-TCLP Compliant See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 4-21 Fluorescent Lamps Bulb Base Nominal Length Order Watts in. Code Description Color Lumens Temp. Initial Mean K CRI Case Rated Qty. Life Warning Foot- and notes Cautions Additional Information SPECIAL APPLICATION LAMPS (CONTINUED) COVRGUARD® SHATTER PROTECTED (CONTINUED) T12 RAPID START LAMPS (CONTINUED) 4’ T12 ECOLUX® RAPID START WATT-MISER® LAMPS (48”) T12 Medium BiPin (G13) 34 48 80489 F34/SP35/RS/WM/ECO/CVG 30 80490 F34/SP41/RS/WM/ECO/CVG 30 80491 F34/SPX41/RS/WM/ECO/CVG 30 80488 F34/WW/RS/WM/ECO/CVG 30 80492 F34/LW/RS/WM/ECO/CVG 30 40805 F34/CW/RS/WM/ECO/CVG 30 41138 F34/SPX30/RS/WM/ECO/CVG 30 41139 F34/SPX35/RS/WM/ECO/CVG 30 4’ T12 RAPID START LAMPS UTILITY SHOPLIGHT (48”) T12 Medium BiPin (G13) 25 48 30 12000 20000 20000 20000 20000 20000 20000 20000 20000 2660 2660 2820 2620 2730 2570 2810 2810 2400 2400 2530 2250 2350 2210 2530 2530 3500 73 4100 72 4100 80 3000 52 4200 49 4100 60 3000 82 3500 82 1800 1620 4100 60 B 1,11,13 B 1,11,13 ✐ 1,11,13 B 1,11,13 B 1,11,13 B 1,11,13 B 1,11,13 ✐ B 1,11,13 ✐ B ✐ ✐ 11,13 103 103 103 103 Warm White 103 Lite White 103 103 103 103 T12 INSTANT START T12 Single Pin (Fa8) 20 24 47342 40 48 40127 48091 41144 50 60 41147 55 72 46213 41151 41153 75 96 40117 46215 41157 41158 41159 41973 46208 T12 INSTANT START ~ F24T12/CW/CVG F48T12/CW/CVG F48T12/SP35/CVG F48T12/SPX35/CVG F60T12/CW/CVG F72T12/SP35/CVG F72T12/SPX30/CVG F72T12/SPX35/CVG F96T12/CW/CVG F96T12/SP35/CVG F96T12/SPX30/CVG F96T12/SPX35/CVG F96T12/SPX41/CVG F96T12/DX/CVG F96T12/C50/CVG WATT-MISER® 24 24 24 24 15 15 15 15 15 15 15 15 15 15 15 7500 9000 9000 9000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 870 2780 2910 2950 3490 4550 4650 4650 5960 6300 6590 6590 6590 4360 4460 785 2560 2730 2780 3210 4280 4370 4370 5480 5920 6190 6190 6190 3920 3920 4100 60 4100 60 4100 60 3500 82 4100 60 3500 73 3000 82 3500 82 4100 60 3500 73 3000 82 3500 82 4100 80 6500 84 5000 90 ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ 11,13 11,13 11,13 11,13 11,13 11,13 11,13 11,13 11,13 11,13 11,13 11,13 11,13 11,13 11,13 103 103 103 103 103 103 103 103 103 103 103 103 103 103 Daylight Deluxe 103 Chroma 50 ENERGY SAVING LAMPS 8’ T12 RAPID START WATT-MISER® LAMPS (96”) T12 Single Pin (Fa8) 58 96 45993 F96T12/SP35/WMP/CVG 60 96 40115 F96T12/CW/WM/CVG 96 40124 F96T12/SP35/WM/CVG 8’ T12 ECOLUX® RAPID START WATT-MISER® LAMPS (96”) T12 Single Pin (Fa8) 60 96 40807 F96T12/CW/WM/ECO/CVG 15 12000 15 12000 15 12000 5520 5190 3500 75 ✐ 5330 4910 4100 60 5520 5200 3500 73 ✐ B 1,11,13 B 1,11,13 B 1,11,13 15 12000 5330 4910 4100 60 103 103 103 1,11,13 103 T12 MOD-U-LINE® ~ WATT-MISER® ENERGY SAVING LAMPS T12 Medium BiPin (G13) 35 22.5 47694 F35/CW/U6/WM/CVG 10 14000 2230 2030 4100 60 10 14000 10 14000 10 14000 2230 2030 3000 73 ✐ 2230 2030 3500 73 ✐ 2230 2030 4100 73 ✐ T12 MOD-U-LINE® 6” SPACING T12 Medium BiPin (G13) 4-22 40 22.5 23661 F40T12/SP30/U6/CVG 23662 F40T12/SP35/U6/CVG 23664 F40T12/SP41/U6/CVG B 1,11,13 11,13 11,13 11,13 103 6’’ Spacing Between Legs 103 103 103 See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Fluorescent Lamps Bulb Base Nominal Length Order Watts in. Code Description Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI Warning Foot- and notes Cautions Additional Information SPECIAL APPLICATION LAMPS (CONTINUED) COVRGUARD® SHATTER PROTECTED (CONTINUED) T12 PREHEAT T12 Medium BiPin (G13) 15 18 41114 20 24 46377 40125 41000 46622 46218 41116 25 33 41120 F15T12/CW/CVG F20T12/C50/CVG F20T12/CW/CVG F20T12/CW/CVG/UPC F20T12/KB/CVG/UPC F20T12/SP35/CVG F20T12/SPX35/CVG F25T12/WW/33/CVG 24 24 24 24 24 24 24 24 9000 9000 9000 9000 9000 9000 9000 7500 735 845 1160 1160 1230 1230 1260 1850 660 765 1110 1110 1160 1160 1180 1660 4100 60 5000 90 4100 60 4100 60 3000 70 3500 73 3500 82 3000 52 1570 3930 4220 3290 4990 6150 6450 6590 6590 4170 7460 8630 8920 8630 9070 9070 9070 7370 6400 1300 3410 3800 2870 4340 5350 5810 5930 5930 3500 6490 7500 8030 7760 8160 8160 8160 6410 5440 4100 60 4100 60 3500 82 6500 75 4150 62 4100 60 3500 73 3000 82 3500 82 3700 90 4100 60 4100 60 3500 73 6500 75 3000 82 3500 82 4100 80 6500 75 6500 84 ✐ ✐ ✐ ✐ 11,13 11,13 11,13 11,13 11,13 11,13 11,13 11,13 103 103 103 103 103 103 103 103 11,12,13 11,12,13 11,12,13 11,12,13 11,12,13 11,12,13 11,12,13 11,12,13 11,12,13 11,12,13 11,12,13 11,12,13 11,12,13 11,12,13 11,12,13 11,12,13 11,12,13 11,12,13 11,12,13 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 Preheat Preheat, Chroma 50 Preheat Preheat, UPC Preheat, Kitchen and Bath, UPC Preheat Preheat Preheat, Warm White T12 HIGH OUTPUT LAMPS RECESSED DOUBLE CONTACT T12 R17d 35 24 48090 60 48 40129 41146 41969 75 60 41148 85 72 40811 46207 41152 41154 48094 100 84 41156 110 96 40808 46210 45264 41160 41161 41162 46424 46430 F24T12/CW/HO/CVG F48T12/CW/HO/CVG F48T12/SPX35/HO/CVG F48T12/D/HO/CVG F60T12/CW/HO/CVG F72T12/CW/HO/CVG F72T12/SP35/HO/CVG F72T12/SPX30/HO/CVG F72T12/SPX35/HO/CVG F72T12/N/HO/CVG F84T12/CW/HO/CVG F96T12/CW/HO/CVG F96T12/SP35/HO/CVG F96T12/SP65/HO/CVG F96T12/SPX30/HO/CVG F96T12/SPX35/HO/CVG F96T12/SPX41/HO/CVG F96T12/D/HO/CVG F96T12/DX/HO/CVG 24 24 24 24 15 15 15 15 15 10 15 15 15 15 15 15 15 15 15 9000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ Daylight Natural Daylight Daylight Deluxe T12 HIGH OUTPUT LAMPS RECESSED DOUBLE CONTACT ~ WATT-MISER® ENERGY SAVING LAMPS T12 R17d 95 96 40116 40118 40123 16821 F96T12/CW/HO/WM/CVG 15 F96T12/SP35/HO/WM/CVG 15 F96T12/SP41/HO/WM/CVG 15 F96T12/CW/HO/WM/ECO/CVG 15 12000 12000 12000 12000 7760 8090 8090 7760 6750 7290 7290 6285 4100 60 3500 73 ✐ 4100 72 ✐ 4100 60 1,11,12,13 103 1,11,12,13 103 1,11,12,13 103 1,11,12,13 103 COLD TEMPERATURE T5 T5 Miniature BiPin (G5) 54 45.2 81521 F54T5/835 81522 F54T5/841 36 30000 36 30000 4500 4275 3500 86 ✐ 4500 4275 4100 86 ✐ 11,13,17 101 Plastic jacket 11,13,17 101 Plastic jacket Medium BiPin (G13) 18 24 31147 31148 36 48 25763 25764 58 60 16148 23752 70 72 16149 23754 12 12 30 30 24 24 18 18 1215 1215 3015 3015 4680 4680 5670 5670 11,13,17 11,13,17 11,13,17 11,13,17 11,13,17 11,13,17 11,13,17 11,13,17 T8 T8 F18WT8/835 F18WT8/841 F36WT8/835 F36WT8/841 F58WT8/835 F58WT8/841 F70WT8/835 F70WT8/841 20000 20000 20000 20000 20000 20000 20000 20000 1152 1152 2860 2860 4450 4450 5386 5386 3500 86 4100 86 3500 86 4100 86 3500 86 4100 86 3500 86 4100 86 ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ 101 101 101 101 101 101 101 101 Plastic jacket Plastic jacket Plastic jacket Plastic jacket Plastic jacket Plastic jacket Plastic jacket Plastic jacket See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 4-23 Fluorescent Lamps Bulb Base Nominal Length Order Watts in. Code Description Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI 15 12000 5960 5490 4100 60 Warning Foot- and notes Cautions Additional Information SPECIAL APPLICATION LAMPS (CONTINUED) COLD TEMPERATURE (CONTINUED) INSTANT START T12 Single Pin (Fa8) 75 96 47350 F96T12/CW-CT 11,13,17 101 Plastic jacket HIGH OUTPUT (800mA) RECESSED DOUBLE CONTACT T12 R17d 35 24 48097 60 48 48530 47352 45976 75 60 47353 85 72 47346 46201 48095 46199 110 96 45979 48096 45912 11918 11919 F24T12/CW/HO-CT F48T12/SP35/HO-AT F48T12/SPX30/HO-CT F48T12/CW/HO-AT F60T12/CW/HO-CT F72T12/SP35/HO-CT F72T12/SP41/HO-CT F72T12/SPX35/HO-CT F72T12/CW/HO-AT F96T12/SP35/HO-CT F96T12/SPX35/HO-CT F96T12/CW/HO-AT F96T12/CW/HO/CT F96T12/D/HO/CT 12 12 24 12 12 8 8 8 8 8 8 8 15 15 9000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 1570 4120 4210 3710 4990 6450 6450 6590 6150 8920 9060 8630 8900 7600 1300 3710 3800 3220 4340 5810 5810 5930 5350 8030 8160 7500 7740 6610 4100 60 3500 73 3000 82 4100 60 4100 60 3500 73 4100 72 3500 82 4100 60 3500 73 3500 82 4100 60 4100 60 6500 75 11,13,17 11,13,17 11,13,17 11,13,17 11,13,17 11,13,17 11,13,17 11,13,17 11,13,17 11,13,17 11,13,17 11,13,17 11,13,17 11,13,17 101 101 101 101 101 101 101 101 101 101 101 101 101 101 4100 60 4100 60 3000 70 ✐ 4100 60 4100 60 4100 60 4100 60 4100 60 4 13, 17 4 4 4 13, 17 4 13, 17 101 101 Plastic jacket 101 101 101 101 Plastic jacket 101 101 Plastic jacket ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ Plastic jacket Plastic jacket w/ vent holes Plastic jacket Plastic jacket w/ vent holes Plastic jacket Plastic jacket Plastic jacket Plastic jacket Plastic jacket w/ vent holes Plastic jacket Plastic jacket Plastic jacket w/ vent holes Plastic jacket Plastic jacket T10 VERY HIGH OUTPUT (1500mA) RECESSED DOUBLE CONTACT T10 R17d 110 48 10742 46196 135 60 17135 39157 13002 46197 160 72 13776 46198 F48T10/CW F48T10/CW/VHO-CT F60T10/SP30 F60T10/CW F60T10/CW 6PK F60T10/CW/VHO-CT F72T10/CW 15PK F72T10/CW/VHO-CT 24 12 24 24 6 12 15 8 9000 9000 6000 6000 6000 6000 9000 9000 6200 6010 8500 7000 7000 6790 9700 9400 T12 VERY HIGH OUTPUT (1500mA) RECESSED DOUBLE CONTACT T12 R17d 110 48 34206 46195 170 72 13762 46200 220 96 13788 F48T12/CW/1500/0 F48T12/CW/VHO-CT F72T12/CW/1500/0 F72T12/CW/VHO-CT F96T12/CW/1500/0 46202 F96T12/CW/VHO-CT 24 12 15 8 15 10000 10000 10000 10000 10000 7000 6790 10800 10470 14400 4100 60 4100 60 4100 60 4100 60 4100 60 4 15, 17 4 15, 17 4 101 101 Plastic jacket 101 101 Plastic jacket 101 8 10000 13960 4100 60 15, 17 101 Plastic jacket DIAZO REPROGRAPHIC 1500mA (SUPERBLUE) T12 T12 Medium BiPin (G13) 120 54 40092 F54”T12/SPB 125 59 39683 F59”T12/SPB 24 24 2000 2000 B 22 B 101 101 180 54 26390 F54”T17/SPB 12 2000 B2 101 24 24 24 24 24 24 7500 7500 7500 7500 7500 7500 T17 T17 Mogul BiPin (G20) APPLIANCE T8 T8 4-24 Medium BiPin (G13) 18 22 24 19 26 26 28 30 10257 17705 10702 38199 17704 10349 F22”T8/D/4 F24”T8/CW/4 6PK F26”T8/CW/4 F26”T8/CW/4 6PK F28”T8/CW/4 6PK F30”T8/CW/4 925 1225 1275 1275 1350 1375 790 1040 1085 1085 1145 1170 6500 75 ✐ 4100 60 4100 60 4100 60 4100 60 4100 60 101 Daylight 101 101 101 101 101 See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Fluorescent Lamps Bulb Base Nominal Length Order Watts in. Code Description Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI Warning Foot- and notes Cautions Additional Information SPECIAL APPLICATION LAMPS (CONTINUED) APPLIANCE (CONTINUED) T12 T12 Medium BiPin (G13) 21 30 10355 25 28 10282 10286 33 38201 10299 10293 F30”T12/CW F25T12CW/28 6PK F25T12/D/28 F25T12/CW/33 6PK F25T12/D/33 F25T12/WW/33 24 24 24 24 24 24 7500 7500 7500 7500 7500 7500 1350 1550 1450 1860 1600 1910 1220 1390 1310 1675 1440 1720 4100 60 4100 60 6500 75 ✐ 4100 60 6500 75 ✐ 3000 52 101 101 101 Daylight 101 101 Daylight 101 Warm White BLACKLIGHT/BLACKLIGHT BLUE BLACKLIGHT T8 Medium BiPin (G13) T12 Medium BiPin (G13) 15 18 35884 F15T8/BL 6PK 20 24 10244 F20T12/BL 6PK 40 22.5 40537 F40BL/U/3 24 7500 24 9000 12 14000 8 8 8 48 10526 F40BL 6PK 24 20000 8 6 10019 F4T5/BLB 24 5000 8 8 12 10077 F8T5/BLB 24 5000 8 24 7500 8 6 12000 8 105 Blacklight, UVA Source 105 Blacklight, UVA Source 105 Blacklight, UVA Source, Mod-U-Line®; 3 5/8’’ Spacing Between Legs 105 Blacklight, UVA Source BLACKLIGHT BLUE T5 Miniature BiPin (G5) 4 T8 Medium BiPin (G13) 15 18 35885 F15T8/BLB 6PK T9 4 Pin (G10q) 22 8.25 25665 FC8T9/BLB T12 Medium BiPin (G13) 20 24 34747 F20T12/BLB 6PK 24 9000 8 40 48 10531 F40BLB 6PK 24 20000 8 32 48 15992 F32T8/R/24/ECO/CVG 15993 F32T8/B/65/ECO/CVG 15994 F32T8/G/89/ECO/CVG 36 20000 36 20000 36 20000 40 48 10514 10517 81003 81001 81002 F40/B 6 PK F40/G 6 PK F40T12/R24/ECO/CVG F40T12/B65/ECO/CVG F40T12/G89/ECO/CVG 24 24 30 30 30 20000 20000 20000 20000 20000 20 24 48259 48260 48261 10231 10233 F20T12/R/24/CVG F20T12/B/65/CVG F20T12/G/89/CVG F20T12/B 6PK F20T12/G 6PK 24 24 24 24 24 9000 9000 9000 9000 9000 101 Blacklight Blue, UVA Source, Integral Dark Blue Filter 101 Blacklight Blue, UVA Source, Integral Dark Blue Filter 101 Blacklight Blue, UVA Source, Integral Dark Blue Filter 101 Blacklight Blue, UVA Source, Integral Dark Blue Filter 101 Blacklight Blue, UVA Source, Integral Dark Blue Filter 101 Blacklight Blue, UVA Source, Integral Dark Blue Filter COLORED LAMPS T8 T8 Medium BiPin (G13) 103 Sleeved Rosco Red 24 103 Sleeved Rosco Blue 65 103 Sleeved Rosco Green 89 T12 T12 Medium BiPin (G13) 1200 720 4000 2000 101 101 103 103 103 Phosphor Blue Phosphor Green Sleeved Rosco Red 24 Sleeved Rosco Blue 65 Sleeved Rosco Green 89 103 103 103 101 101 Sleeved Rosco Red 24 Sleeved Rosco Blue 65 Sleeved Rosco Green 89 Phosphor Blue Phosphor Green PREHEAT T12 Medium BiPin (G13) 450 1575 330 975 GOLD T5 LAMPS T5 Miniature BiPin (G5) 28 45.2 25768 F28T5/GO/CVG 40 20000 1986 1946 GoldN/A 103 See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 4-25 Fluorescent Lamps Bulb Base Nominal Length Order Watts in. Code Description Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI Warning Foot- and notes Cautions Additional Information GOLD (CONTINUED) T8 LAMPS T8 Medium BiPin (G13) 17 24 25779 F17T8/GO/CVG 24 20000 970 950 GoldN/A 15 36 25783 F25T8/GO/CVG 24 20000 1590 1558 GoldN/A 32 48 25784 F32T8/GO/CVG 36 20000 2280 2235 GoldN/A 36 48 81334 F36T8/GO/CVG 25 20000 2600 2545 GoldN/A 58 60 80053 F58T8/GO/CVG 25 20000 4080 4000 GoldN/A 59 96 25810 F96T8/GO/CVG 24 20000 4492 4400 GoldN/A 40 48 25850 F40/G0/CVG 30 20000 2510 2460 GoldN/A 55 72 25854 F72T12/GO/CVG 15 12000 4150 4070 GoldN/A 75 96 25852 F96T12/GO/CVG 15 12000 5640 5530 GoldN/A 15 12000 8010 7850 GoldN/A 40 48 81000 F40T12/FL/ECO/CVG 30 20000 1925 1450 2750 4 6 8 11 16 39 65 103 Gold Sleeved, Blocks UV and Deep Blue Emissions 103 Gold Sleeved, Blocks UV and Deep Blue Emissions 103 Gold Sleeved, Blocks UV and Deep Blue Emissions 103 Gold Sleeved, Blocks UV and Deep Blue Emissions 103 Gold Sleeved, Blocks UV and Deep Blue Emissions 103 Gold Sleeved, Blocks UV and Deep Blue Emissions T12 LAMPS T12 Medium BiPin (G13) Single Pin (Fa8) R17d 110 96 25853 F96T12/GO/HO/CVG 103 Gold Sleeved, Blocks UV and Deep Blue Emissions 103 Gold Sleeved, Blocks UV and Deep Blue Emissions 103 Gold Sleeved, Blocks UV and Deep Blue Emissions 103 Gold Sleeved, Blocks UV and Deep Blue Emissions GROCERY DISPLAY LAMPS T12 Medium BiPin (G13) CovRFresh® GERMICIDAL T5 Miniature BiPin (G5) Single Pin (Fa8) 6 8 12 11.9 8.91 36 64 15872 15873 11077 29495 16495 15874 15864 G4T5 G6T5 G8T5 G11T5 G16T5 G36T5 G64T5 24 24 24 24 24 24 24 6000 6000 6000 8000 8000 9000 9000 9, 16 9, 16 9, 16 9, 16 9, 16 9, 16 9, 16 106 106 106 106 106 106 106 Clear, UVC Source Clear, UVC Source Clear, UVC Source Clear, UVC Source Clear, UVC Source Clear, UVC Source Clear, UVC Source 29498 11078 11082 11080 29499 15875 15876 29532 G10T8 G15T8 G25T8 G30T8 G36T5 G55T8/HO G20T10 G40T10 24 24 24 24 24 24 24 24 6000 8000 8000 8000 8000 8000 8000 8000 9, 16 9, 16 9, 16 9, 16 9, 16 9, 16 9, 16 9, 16 106 106 106 106 106 106 106 106 Clear, UVC Source Clear, UVC Source Clear, UVC Source Clear, UVC Source Clear, UVC Source Clear, UVC Source Clear, UVC Source Clear, UVC Source F14T8/AR/FR 6PK F14T8/AR/FS/6PK F14T8/AR/SA 6PK F14T8/SR 6PK 24 24 24 24 7500 7500 7500 7500 360 550 190 565 4000 92 ✐ 9325 64 1000062 5000 90 ✐ 104 104 104 104 Aquarium Lamp Freshwater Aquarium Lamp Fresh and Saltwater Aquarium Lamp Saltwater Aquarium/Terrarium Lamp 15 18 22907 F15T8/AR/FR 6PK 22910 F15T8/AR/FS 6PK 24 24 7500 7500 425 675 4000 92 ✐ 9325 64 104 Aquarium Lamp Freshwater 104 Aquarium Lamp Fresh and Saltwater GERMICIDAL (CONTINUED) T8 Medium BiPin (G13) T10 Medium BiPin (G13) 10 15 25 30 36 55 20 40 13.6 18 18 36 48 36 24 48 PLANT AND AQUARIUM/TERRARIUM T8 LAMPS 15” T8 LAMPS T8 Medium BiPin (G13) 14 15 41373 40903 41375 41377 18” T8 LAMPS T8 4-26 Medium BiPin (G13) See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Fluorescent Lamps Bulb Base Nominal Length Order Watts in. Code Description Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI Warning Foot- and notes Cautions Additional Information PLANT AND AQUARIUM/TERRARIUM (CONTINUED) T8 LAMPS (CONTINUED) 18” T8 LAMPS (CONTINUED) T8 Medium BiPin (G13) 15 18 22920 F15T8/AR/SA 6PK 49892 F15T8/PL/AQ 6PK 22904 F15T8/SR 6PK 24 24 24 7500 7500 7500 210 510 620 1000 62 3100 90 ✐ 5000 90 ✐ 104 Aquarium Lamp Saltwater 104 Plant & Aquarium Wide Spectrum 104 Aquarium/Terrarium Lamp 30 36 41374 F30T8/AR/FR 6PK 40904 F30T8/AR/FS 6PK 41376 F30T8/AR/SA 6PK 24 24 24 9000 9000 9000 630 1400 315 4000 92 ✐ 9235 64 1000062 104 Aquarium Lamp Freshwater 104 Aquarium Lamp Fresh and Saltwater 104 Aquarium Lamp Saltwater 20 24 22908 22911 22922 49891 22905 24 24 24 24 24 9000 9000 9000 9000 9000 600 950 270 750 875 4000 92 ✐ 9325 64 1000 62 3100 90 ✐ 5000 90 ✐ 104 104 104 104 104 30 36 41378 F30T12/SR 6PK 24 18000 1100 5000 90 ✐ 104 Aquarium/Terrarium Lamp 40 48 22909 22914 22923 49893 22906 24 9000 24 9000 24 9000 24 20000 24 20000 1425 2350 700 1900 2250 4000 92 ✐ 9325 64 1000 62 3100 90 ✐ 5000 90 ✐ 104 104 104 104 104 Aquarium Lamp Freshwater Aquarium Lamp Fresh and Saltwater Aquarium Lamp Saltwater Plant & Aquarium Wide Spectrum Aquarium/Terrarium Lamp F40CW/U/6/EX F40D/U/6/EX F40CW/EX-30PK F40D/EX F96T12CW/EX-15PK F96T12/D/EX-15PK F96T12CW/HO/EX F96T12D/HO/EX-15 12 12 30 30 15 15 15 15 14000 14000 20000 20000 12000 12000 12000 12000 2800 2350 3050 2550 6150 5250 8900 7600 2460 2070 2680 2240 5660 4330 7740 6610 4100 60 6500 75 4100 60 6500 75 4100 60 6500 75 4100 60 6500 75 102 102 101 101 101 101 101 101 6” Spacing Between Legs Daylight, 6’’ Spacing Between Legs F32T8/SP30/ECO/UPC F32T8/SP35/ECO/UPC F32T8/SP35/ECO 12PK F32T8/SP41/ECO/UPC F32T8/SP41/ECO/C F32T8/RESI/ECO/2PK F32T8/RES/ECO/2PK F32T8/KB/ECO/2PK F32T8/KB/ECO/2PK-24 F32T8/D/ECO/2PK F32T8/D/ECO/TW 36 36 12 36 12 6 24 6 24 24 6 20000 20000 20000 20000 20000 15000 15000 20000 20000 20000 20000 2800 2800 2800 2800 2800 2650 2650 2800 2800 2700 2700 2660 2660 2660 2660 2660 2385 2385 2660 2660 2565 2565 3000 78 3500 78 3500 78 4100 78 4100 78 4100 78 4100 78 3000 78 3000 78 6500 78 6500 78 36” T8 LAMPS T8 Medium BiPin (G13) T12 LAMPS 24” T12 LAMPS T12 Medium BiPin (G13) F20T12/AR/FR 6PK F20T12/AR/FS 6PK F20T12/AR/SA 6PK F20T12/PL/AQ 6PK F20T12/SR 6PK Aquarium Lamp Freshwater Aquarium Lamp Fresh and Saltwater Aquarium Lamp Saltwater Plant & Aquarium Wide Spectrum Aquarium/Terrarium Lamp 36” T12 LAMPS T12 Medium BiPin (G13) 48” T12 LAMPS T12 Medium BiPin (G13) F40T12/AR/FR 6PK F40T12/AR/FS 6PK F40T12/AR/SA 6PK F40PL/AQ 6PK F40T12/SR 6PK EXPORT OUTSIDE U.S. AND CANADA ONLY T12 Medium BiPin (G13) Single Pin (Fa8) R17d 40 22.5 14496 14498 40 48 14656 14488 75 96 12541 12543 110 96 12540 12542 ✐ ✐ ✐ ✐ Daylight Daylight Daylight CONSUMER PRODUCTS T8 4’ T8 T8 Medium BiPin (G13) 32 48 15900 15903 11873 15909 15904 16263 31231 49356 49357 29566 87783 ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ 101 101 101 101 101 101 101 104 104 101 101 Kitchen & Bath Kitchen & Bath Daylight Daylight Means this lamp meets Federal Minimum Efficiency Standards. See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 4-27 Fluorescent Lamps Bulb Base Nominal Length Order Watts in. Code Description Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI 24 15000 5800 5500 4100 78 10 30 30 9 24 9 24 24 9 30 24 9 15 20000 20000 20000 20000 20000 20000 20000 20000 20000 15000 15000 15000 15000 3200 3050 2250 3050 3050 3400 3400 2250 3200 3150 3150 3150 3150 30 30 9 15 12000 12000 12000 12000 Warning Foot- and notes Cautions Additional Information CONSUMER PRODUCTS (CONTINUED) T8 8’ T8 T8 Single Pin (Fa8) 59 96 10401 F96T8/SP41/UPC ✐ 101 2910 2775 1870 2775 2775 3090 3090 1870 2910 2860 2860 2860 2860 4100 72 ✐ 6500 75 ✐ 5000 90 ✐ 6500 75 ✐ 6500 75 ✐ 3000 70 ✐ 3000 70 ✐ 5000 90 ✐ 4100 72 ✐ 4100 72 ✐ 4100 72 ✐ 4100 72 ✐ 4100 72 ✐ 101 101 101 101 101 104 104 101 101 101 101 101 101 1860 1860 1860 1860 1675 1675 1675 1675 4100 60 4100 60 4100 60 4100 60 2750 2750 2750 2750 2750 2650 2650 2700 2475 2475 2475 2475 2475 2280 2280 2320 3000 70 3500 73 3500 73 4100 72 4100 72 4100 60 4100 60 3000 52 T12 4’ F40 ECOLUX® STANDARD T12 Medium BiPin (G13) 40 48 23382 25400 25399 16083 13969 40333 21323 12224 10949 14440 14433 14441 48510 F40SP41/ECO/C F40SP65/ECO/UPC F40/C50/ECO/UPC F40D/ULTRA/ECO/2PK F40D/ULTRA/ECO/6PK F40/KB/ECO 2PK F40/KB/ECO 6PK F40/SUN/ECO/6PK F40/RES/ECO/LL/2PK F40/RES/ECO/SLV F40/RES/ECO/SLV 6PK F40/RES/ECO/TWIN-9PK F40/RES/ECO/TWIN-15PK Chroma 50 Daylight Ultra Daylight Ultra Kitchen & Bath Kitchen & Bath Sunlight 4’ ECOLUX® UTILITY SHOPLIGHT T12 Medium BiPin (G13) 25 48 14445 14450 14456 48511 F48”/25W/UTECOUPC F48”/25W/UTECOSLV F48”/25W/UTECOTWN F48”/25W/UTECO2PK 10 10 10 10 101 101 101 101 4’ F34 ECOLUX® WATT-MISER® ENERGY SAVING LAMPS T12 Medium BiPin (G13) 34 48 25401 23486 21858 40372 25397 25391 23485 25398 F34/SP30/RS/WM/ECO/UPC 30 F34/SP35/WM/ECO/C 10 F34/SP35/RS/WM/ECO/UPC 24 F34/SP41/RS/WM/ECO 24 F34/SP41/RS/WM/ECO/UPC 30 F34/CW/RS/WM/ECO/UPC 30 F34/CW/RS/WM/ECO/C 10PK 10 F34/WW/RS/WM/ECO/UPC 30 20000 20000 20000 20000 20000 20000 20000 20000 MOD-U-LINE® WATT-MISER® U-TUBES T12 Medium BiPin (G13) 35 22.5 14471 F35/CW/U/6/WM/UPC 23383 F35/CW/U6/WM/C ✐ B 11 B 101 101 101 101 101 101 101 101 Warm White 12 14000 6 14000 2300 2100 4100 60 2300 2100 4100 60 40 22.5 22050 F40/SP35/U/6/UPC 25374 F40/SCW/U6/UPC 6PK 12 14000 6 14000 3050 2780 3500 73 ✐ 2800 2460 4100 75 ✐ 102 102 Super Cool White 40 48 20461 F48T12/CW/UPC 6PK 24 2875 2650 4100 60 101 75 96 10149 F96T12/SP41/UPC 15 12000 6500 6110 4100 72 ✐ 101 MOD-U-LINE® STANDARD U-TUBES T12 Medium BiPin (G13) B 11 B1 ✐ B1 ✐ B1 ✐ B B 11 B B1 ✐ 102 102 T12 INSTANT START 4’ T12 T12 Single Pin (Fa8) 8’ T12 T12 Single Pin (Fa8) 9000 Means this lamp meets Federal Minimum Efficiency Standards. 4-28 See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Fluorescent Lamps Bulb Base Nominal Length Order Watts in. Code Description Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI Warning Foot- and notes Cautions Additional Information CONSUMER PRODUCTS (CONTINUED) T12 (CONTINUED) 8’ T12 WATT-MISER® ENERGY SAVING LAMPS T12 Single Pin (Fa8) 60 96 21856 F96T12/SP35/WM/UPC 11217 F96T12/SP35/WM/C 10PK 25395 F96T12/SP41/WM/UPC 21713 F96T12/CW/WM/UPC 10PK 25171 F96T12/UTCW/EE/C 8’ T12 ECOLUX® WATT-MISER® ENERGY SAVING LAMPS T12 Single Pin (Fa8) 60 96 16816 F96T12/CW/WM/ECO 15 10 15 10 10 12000 12000 12000 12000 12000 5700 5700 5700 5500 5500 5360 5360 5360 5060 5060 3500 73 ✐ 3500 73 ✐ 4100 72 ✐ 4100 60 4100 60 B 11 B1 B B 11 B 101 101 101 101 101 15 12000 5500 5060 4100 60 ✐ 1 101 B T12 RAPID START T12 Medium BiPin (G13) 30 36 39176 F30T12/CW/RS 6PK 77119 F30T12/RS/KB/PM 24 18000 24 18000 2200 1910 4100 60 2350 2120 3000 70 ✐ 101 104 Kitchen & Bath 4050 3520 4100 60 8000 6960 4100 60 101 101 T12 HIGH OUTPUT RAPID START RECESSED DOUBLE CONTACT T12 R17d 60 48 27313 F48T12/CW/HO/UPC 24 12000 95 96 21714 F96T12/CW/HO/WM/UPC 15 12000 B1 PREHEAT T5 T5 Miniature BiPin (G5) 4 6 15983 F4T5/CW CARD 6 9 15986 F6T5/CW CARD 8 12 15987 F8T5/CW CARD 25425 F8T5/WW/CARD 13 21 25426 F13T5/WW/CARD 10 10 10 5 5 5000 5000 5000 5000 5000 Medium BiPin (G13) 15 18 13968 F15T8/SUN 6PK 30 36 22747 F30T8/KB 6PK 15 18 46982 F15T12/KB-TP 46981 F15T8/KB-TP 21326 F15T8/KB/6PK 10143 F15T8/CW/6PK 46980 F15T8/SUN-TP 24 24 24 24 24 24 24 7500 7500 9000 7500 7500 7500 7500 14 15 10117 22979 15 18 10183 22745 20 24 80046 25575 21325 14419 25577 10231 10233 46914 46826 30 36 46917 24 9000 24 9000 24 9000 24 9000 24 9000 24 9000 24 9000 24 9000 24 9000 24 9000 24 9000 24 9000 24 9000 24 18000 135 295 400 410 870 100 235 320 330 720 4100 60 4100 60 4100 60 3000 52 3000 52 101 101 101 101 101 Preheat Preheat Preheat Preheat, Warm White Preheat, Warm White 620 525 5000 90 ✐ 2125 1910 3000 70 ✐ 785 730 3000 70 ✐ 940 850 3000 70 ✐ 940 850 3000 70 ✐ 825 725 4100 60 ✐ 620 525 5000 90 ✐ 101 104 104 104 104 101 101 Preheat, Sunlight Preheat, Kitchen & Bath Preheat, Kitchen & Bath Preheat, Kitchen & Bath Preheat, Kitchen & Bath Preheat Preheat, Sunlight 650 700 760 785 1200 1025 1275 875 1250 450 1575 1275 875 2350 101 104 104 104 101 101 104 101 101 101 101 104 101 104 Preheat Preheat, Kitchen & Bath Preheat, Kitchen & Bath Preheat, Kitchen & Bath Preheat Preheat, Daylight Preheat, Kitchen & Bath Preheat, Sunlight Preheat, Warm White Preheat Preheat Preheat, Kitchen & Bath Preheat, Sunlight Preheat, Kitchen & Bath T8 T8 T12 T12 Medium BiPin (G13) F14T12/CW 6PK F14T12/KB 6PK F15T12/CW 6PK F15T12/KB 6PK F20T12/CW/ECO/6PK F20T12/D/ECO/UPC F20T12/KB/ECO/6PK F20T12/SUN/ECO/6PK F20T12/WW/ECO/UPC F20T12/B 6PK F20T12/G 6PK F20T12/KB/ECO-TP F20T12/SUN/ECO-TP F30T12/KB/ECO-TP 550 650 685 730 1150 945 1200 790 1150 330 957 1200 790 2120 4100 60 3000 70 4100 60 3000 70 4100 60 6500 75 3000 70 5000 90 3000 52 ✐ ✐ ✐ ✐ 3000 70 ✐ 5000 90 ✐ 3000 70 ✐ Means this lamp meets Federal Minimum Efficiency Standards. See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 4-29 Fluorescent Lamps Bulb Base Nominal Length Order Watts in. Code Description Case Rated Qty. Life Color Lumens Temp. Initial Mean K CRI Warning Foot- and notes Cautions Additional Information CONSUMER PRODUCTS (CONTINUED) BLACKLIGHT T8 Medium BiPin (G13) T12 15 18 35884 F15T8/BL 6PK 20 24 10244 F20T12/BL 6PK 40 48 10526 F40BL 6PK 24 7500 24 9000 24 20000 15 18 35885 F15T8/BLB 6PK 24 7500 20 24 34747 F20T12/BLB 6PK 24 9000 8 8 8 105 Blacklight, UVA Source 105 Blacklight, UVA Source 105 Blacklight, UVA Source BLACKLIGHT BLUE T8 Medium BiPin (G13) T12 Medium BiPin (G13) T9 4 Pin (G10q) T12 Medium BiPin (G13) 101 Blacklight Blue, UVA Source, Integral Dark Blue Filter 101 Blacklight Blue, UVA Source, Integral Dark Blue Filter 101 Blacklight Blue, UVA Source, Integral Dark Blue Filter 101 Blacklight Blue, UVA Source, Integral Dark Blue Filter 22 8.25 25665 FC8T9/BLB 6 12000 40 48 10531 F40BLB 6PK 24 20000 20 6.5 42732 22 8.25 33774 11026 11084 32 12 33890 11039 11085 40 16 33893 11052 12 12 12 6 12 12 6 12 12 12000 12000 12000 12000 12000 12000 12000 12000 12000 800 1100 925 1400 1950 1675 2400 2700 2250 24 7500 910 T9 CIRCLINE® T9 4 Pin (G10q) FC6T9/CW FC8T9/CW FC8T9/D FC8T9/KB FC12T9/CW FC12T9/D FC12T9/KB FC16T9/CW FC16T9/D 560 825 690 1120 1460 1260 1920 2030 1690 4100 60 4100 60 6500 75 3000 82 4100 60 6500 75 3000 82 4100 60 6500 75 101 101 101 104 101 101 104 101 101 ✐ ✐ ✐ ✐ ✐ Daylight Kitchen & Bath Daylight Kitchen & Bath Daylight COVRGUARD® SHATTER RESISTANT T8 PREHEAT T8 Medium BiPin (G13) 15 18 46627 F15T8/KB/CVG/UPC 825 3000 70 ✐ 11, 13 104 Kitchen & Bath 1800 1620 4100 60 3290 2990 3000 82 ✐ 2930 2370 4100 60 11, 13 11, 13 11, 13 103 108 Kitchen & Bath 103 T12 RAPID START T12 Medium BiPin (G13) 25 48 46625 F48”/25W/UTSL/CVG/UPC 30 12000 40 48 80995 F40/KB/ECO/CVG/UPC 24 20000 80999 F40/CW/ECO/CVG/UPC 30 20000 T12 RAPID START WATT-MISER® T12 Medium BiPin (G13) 34 48 80997 F34/CW/WM/ECO/CVG/UPC 30 20000 2570 2210 4100 60 B 1, 11, 13 103 20 24 80984 F20T12/CW/ECO/CVG/UPC 24 80985 F20T12/KB/ECO/CVG/UPC 24 1160 1110 4100 60 1230 1160 3000 70 ✐ T12 PREHEAT T12 Medium BiPin (G13) 9000 9000 11, 13 11, 13 103 108 Kitchen & Bath T12 INSTANT START T12 Single Pin (Fa8) 60 96 41002 F96T12/CW/WM/CVG/UPC 15 12000 5330 4910 4100 60 ® B 1, 11, 13 103 Watt-Miser PLANT AND AQUARIUM / TERRARIUM T8 4-30 Medium BiPin (G13) 14 15 41373 40903 41375 41377 15 18 22907 22910 22920 49892 22904 F14T8/AR/FR 6PK F14T8/AR/FS/6PK F14T8/AR/SA 6PK F14T8/SR 6PK F15T8/AR/FR 6PK F15T8/AR/FS 6PK F15T8/AR/SA 6PK F15T8/PL/AQ 6PK F15T8/SR 6PK 24 24 24 24 24 24 24 24 24 7500 7500 7500 7500 7500 7500 7500 7500 7500 360 550 190 565 425 675 210 510 620 4000 92 9325 64 1000062 5000 90 4000 92 9325 64 1000062 3100 90 5000 90 ✐ ✐ ✐ ✐ ✐ 104 104 104 104 104 104 104 104 104 Aquarium Lamp Freshwater Aquarium Lamp Fresh and Saltwater Aquarium Lamp Saltwater Aquarium/Terrarium Lamp Aquarium Lamp Freshwater Aquarium Lamp Fresh and Saltwater Aquarium Lamp Saltwater Plant & Aquarium Wide Spectrum Aquarium/Terrarium Lamp See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B Fluorescent Lamps Bulb Base Nominal Length Order Watts in. Code Description Case Qty. Rated Life Color 3hr/ 12hr/ Lumens Temp. Start Start Initial Mean K CRI Warning Foot- and notes Cautions Additional Information CONSUMER PRODUCTS (CONTINUED) PLANT AND AQUARIUM / TERRARIUM (CONTINUED) T12 Medium BiPin (G13) T8 Medium BiPin (G13) T12 Medium BiPin (G13) 20 24 22908 22911 22922 49891 22905 30 36 41374 40904 41376 30 36 41378 40 48 22909 22914 22923 49893 22906 F20T12/AR/FR 6PK F20T12/AR/FS 6PK F20T12/AR/SA 6PK F20T12/PL/AQ 6PK F20T12/SR 6PK F30T8/AR/FR 6PK F30T8/AR/FS 6PK F30T8/AR/SA 6PK F30T12/SR 6PK F40T12/AR/FR 6PK F40T12/AR/FS 6PK F40T12/AR/SA 6PK F40PL/AQ 6PK F40T12/SR 6PK 24 9000 24 9000 24 9000 24 9000 24 9000 24 9000 24 9000 24 9000 24 18000 24 9000 24 9000 24 9000 24 20000 24 20000 600 950 270 750 875 630 1400 315 1100 1425 2350 700 1900 2250 4000 92 9325 64 1000062 3100 90 5000 90 4000 92 9235 64 1000062 5000 90 4000 92 9325 64 1000062 3100 90 5000 90 ✐ ✐ ✐ ✐ ✐ ✐ ✐ ✐ 104 104 104 104 104 104 104 104 104 104 104 104 104 104 Aquarium Lamp Freshwater Aquarium Lamp Fresh and Saltwater Aquarium Lamp Saltwater Plant & Aquarium Wide Spectrum Aquarium/Terrarium Lamp Aquarium Lamp Freshwater Aquarium Lamp Fresh and Saltwater Aquarium Lamp Saltwater Plant & Aquarium Wide Spectrum Aquarium Lamp Freshwater Aquarium Lamp Fresh and Saltwater Aquarium Lamp Saltwater Plant & Aquarium Wide Spectrum Aquarium/Terrarium Lamp OPERATING NOTES GENERAL OPERATION GE fluorescent lamps should be used only with auxiliary equipment designed to produce proper characteristics. Specifications for auxiliary equipment are covered by ANSI. Specifications for auxiliary equipment not included in ANSI Standards are available from GE Lighting. FACTORS AFFECTING LAMP PERFORMANCE Ballasts The three basic types of ballasts for fluorescent lamps are Preheat (PH), Instant Start (IS), and Rapid Start (RS). In general, lamps identified as preheat, rapid start or instant start should be used only on the corresponding ballast type. Electronic ballasts are presently available in both instant start and rapid start designs. Ballasts that operate with output currents below recommended levels, either by design or poor performance, will reduce fluorescent lamp life. Application - Choosing the appropriate ballast for an application can have an impact on lamp life. For example, T8 lamps with electronic Instant Start ballasts should not be used in applications with electronic controls (such as occupancy sensors). The frequent switching will significantly reduce lanp life. Use only programmed rapid start ballasts in these situations. Operating Characteristics - Fluorescent lamp life is strongly affected by the ballast. ANSI has set standards for fluorescent ballasts that will ensure proper operation of fluorescent lamps. Ballast characteristics that have a significant effect on lamp life are Current Crest Factor, Starting Time, Cathode Voltage and Open Circuit Voltage. Ballast Factor - This is the percentage of a lamp’s rated lumen output that can be expected when operated on a specific, commercially available ballast. For example, a ballast having a ballast factor of 0.93 will result in the lamp emitting 93% of its rated lumen output. High Frequency - All fluorescent lamps operate more efficiently when driven at frequencies greater than 15 kHz. Four-foot fluorescent lamps operate approximately 10% more efficiently, while eight-foot lamps improve efficiency by about 5%. This efficiency improvement is one reason for the popularity of electronic ballasts. Temperature Light output and watts of a fluorescent lamp are affected by the ambient temperature, and by drafts. Most fluorescent lamps reach their maximum light output at room temperatures or at “luminaire temperatures.” All-Weather fluorescent lamps are designed with jackets that improve performance in low temperature environments. Luminaire The design of the lighting fixture (luminaire) affects the ambient temperature in which the fluorescent lamps will be operating. A fixture that operates too cool or warm will result in lower light output from the lamps and reduce illumination levels. Starting The life of a fluorescent lamp is affected by the number of times the lamp is started. Starting results in shorter lamp life, while continuous operation will provide the longest lamp life. All fluorescent lamps, except where noted, have life ratings based on 3 hours per start. See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 4-31 Fluorescent Lamps GENERAL INFORMATION LUMENS Performance Notes: T8 Lamps: • Rated life for F32T8, F32T8/XL or SXL, and F32T8/HL/XL lamps is rated life on rapid start and instant start circuits. See product section for lamp specific ratings. • Rated life for F32T8/WM and F32T8/WM/XL and the F28T8/UMX lamps is rated life on instant start circuits. • Rated life for F17T8 and F25T8 (including XL versions), as well as, the F40T8 is rated life on rapid start circuits. Rated life for these linear lamps on instant start electronic circuits is reduced by 25%. T12 Lamps: Life of 4' T12 lamps on single-lamp, rapid start ballasts may be reduced. Nominal Initial Lumens refer to the nominal light output of the lamp after 100 hours of operation at 25° C. Nominal Mean Lumens refer to the nominal light output of the lamp at 40% of its rated life. Some values are based on engineering calculations derived from extrapolation of initial measured lumens. A self-ballasted lamp is measured using its integral ballast. Lamps without an integral ballast are measured using reference ballasts. Lumens produced by lamps operated on commercial ballasts may not be equivalent to reference ballast ratings. For lighting design calculations, refer to the ballast manufacturer’s published data for the appropriate “Ballast Factor”. NOMINAL WATTS COLOR TEMPERATURE / CHROMATICITY Wattage is classified in accordance with American National Standards Institute standards and may not be the same as the wattage run on a reference ballast. The nominal wattage as defined by ANSI may vary from the listed wattage. Watts consumed by lamps operated on commercial ballasts may not be equivalent to reference ballast ratings. The watts shown for self ballasted lamps are nominal system watts. Approximate color temperature of fluorescent is measured using industry standard methods and is based on a nominal 40-watt source. Fluorescent sources operating at different lamp currents will have slightly shifted color appearances when compared to the corresponding 40-watt sources. SCOTOPIC/PHOTOPIC RATIO RATED LIFE This measurement accounts for the fact that of the two light sensors in the retina, rods are more sensitive to blue light (Scotopic Vision) and cones to yellow light (Photopic Vision). The Scotopic/Photopic (S/P) Ratio is an attempt to capture the relative strengths of these two responses. S/P is calculated as the ratio of scotopic lumens to photopic lumens, for the light source, on an ANSI reference ballast. Cooler sources (higher color temperature lamps) tend to have higher values of the S/P Ratio compared to warm sources. The rated life (hours) is the approximate median life when lamps are operated for three hours per start under laboratory conditions using ballasts which meet industry standards or GE Lighting specifications where no industry standards exist. Rated life for self-ballasted lamps is the approximate median life when operated for three hours per start under laboratory conditions. Some lamps are rated at 12 hours per start where noted. FOOTNOTES SCOTOPIC/PHOTOPIC (S/P) RATIO: # Footnote 1 Watt-Miser® , Watt-Miser® Plus, F28T8/UMX and Energy Efficient (/EE) lamps are intended for use where ambient temperatures are 60°F (16°C) or higher and where the lamp surface is protected from strong air drafts. Failure to protect the lamp surface may result in reduced life, poor starting or erratic operation, such as flickering or spiraling. These lamps are not recommended for use with dimming systems. All T12 Watt-Miser® lamps are intended for use on two-lamp, indoor, lead, high power factor ballasts and are not recommended for use with dimming or reduced current systems. The use of T12 Watt-Miser® lamps on single lamp ballasts may shorten lamp life. T12 Rapid Start Watt-Miser® lamps are intended for use only with Rapid Start Ballasts. F34 Rapid Start Watt-Miser® lamps on high frequency electronic systems may display erratic starting before end of life. T8 Watt-Miser® lamps and F28/UMX lamps are intended for use only with instant start ballasts. They are, however, also approved for use on GE UltraStart programmed rapid start ballasts. Reprographic Peak Emission 417nm. 2000 hours useful life; burning hours longer. F40T17/CW/IS lamps are for use only in fixtures equipped with instant start ballasts. Because Power Groove® and Very High Output lamps are most used in commercial applications, the life rating is based on 12 hrs. per start. Bare “Cold Temperature” lamps (as indicated by /CT) and “All Temperature” lamps are designed for use where ambient temperatures drop below 60°F (16°C). Performance data based on engineering estimates. CAUTION: Risk Group 1 (Low Risk): UV emitted from this lamp. Skin or eye irritation could result. Minimize exposure. WARNING: Risk Group 3 (High Risk): UV emitted from this lamp. Avoid exposure of eyes and skin to unshielded lamp. Skin or eye injury will result. Shoplites are not recommended to be used on F40 full light output ballasts. Life will be reduced by approximately 50%. Lumen rating based on approximate 3% reduction in light output with CovRguard® sleeving. Do not use CovRguard® HO lamps in watertight or airtight fixtures. Blocks 100% of UV-B and UV-C. Blocks from 75 to 99% of UV-A, depending on lamp type. Life rating is based on 12 hrs. per start. Lumen rating based on approximate 3% reduction in light output with jacket. Life rating is based on UV maintenance curve and is measured at 80% of initial (100hr) UVC output. Jacketed “Cold Temperature” lamps (as indicated by -CT) are designed for use where ambient temperatures do not rise above 32°F (0°C). T8 lamps run on Instant Start ballasts should not be used in conjunction with electronic controls such as occupancy sensors. The frequent switching will significantly impact lamp life and void any warranties. Programmed Rapid Start ballasts such as GE’s UltraStart ballast should be used in these situations. T5 Starcoat® Ecolux® lamp initial and mean lumen ratings are taken at 95°F (35°C) 2 3 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 4-32 This measurement accounts for the fact that of the two light sensors in the retina, rods are more sensitive to blue light (Scotopic vision) and cones to yellow light (Photopic vision). The Scotopic/Photopic (S/P) Ratio is an attempt to capture the relative strengths of these two responses. Cooler sources (higher color temperature lamps) tend to have higher values of the S/P Ratio compared to warm sources. T5 830 835 841 850 865 F28T8 SP30 SP35 SP41 SP50 S/P Ratio 1.3 1.5 1.7 1.9 2.2 S/P Ratio 1.3 1.5 1.8 2.0 F17 and F25T8 SP30 SP35 SP41 F17 and F25T8 SPX30 SPX35 SPX41 SPX50 SPX65 S/P Ratio 1.3 1.4 1.6 S/P Ratio 1.3 1.5 1.8 2.0 2.3 See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B F32 and F32T8/WM S/P Ratio SP30 SP35 SP41 SP50 SP65 1.3 1.4 1.6 1.9 2.1 F32T8 and F32T8/HL S/P Ratio SPX30 SPX35 SPX41 SPX50 SPX65 1.3 1.5 1.8 2.0 2.3 Fluorescent Lamps WARNING AND CAUTION NOTICES 101 106 WARNING Risk of electric shock • Turn power off before inspection, installation or removal CAUTION Lamp may shatter and cause injury if broken • Wear safety glasses and gloves when handling lamp • Do not use excessive force when installing lamp WARNING Risk of electric shock • Turn power off before inspection, installation or removal Lamp emits UV radiation which may cause eye/skin injury. RG-3 • Avoid exposure of eyes and skin to unshielded lamp CAUTION Lamp may shatter and cause injury if broken • Wear safety glasses and gloves when handling lamp • Do not use excessive force when installing lamp 102 WARNING Risk of electric shock • Turn power off before inspection, installation or removal CAUTION Improper handling may cause breakage • Do not carry lamp by bracket Lamp may shatter and cause injury if broken • Wear safety glasses and gloves when handling lamp • Do not use excessive force when installing lamp 107 WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Do not open - there are no servicable parts inside • Do not drill or cut into plastic parts • Avoid direct water/liquid contact • Fully insert plug • Use indoors only CAUTION Lamp may shatter and cause injury if broken • Wear safety glasses and gloves when handling lamp • Lamp is not replaceable. Do not attempt to remove lamp from fixture • Use in permanent installation only — not for portable use Unit will fail if not installed properly • Follow installation instructions 103 WARNING Risk of electric shock • Turn power off before inspection, installation or removal 104 WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Avoid direct water/liquid contact CAUTION Lamp may shatter and cause injury if broken • Wear safety glasses and gloves when handling lamp • Do not use excessive force when installing lamp 108 WARNING Risk of electric shock • Turn power off before inspection, installation or removal • Avoid direct water/liquid contact 105 WARNING Risk of electric shock • Turn power off before inspection, installation or removal CAUTION Lamp emits UV radiation which may cause eye/skin irritation. RG-1 • Minimize exposure Lamp may shatter and cause injury if broken • Wear safety glasses and gloves when handling lamp • Do not use excessive force when installing lamp See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 4-33 Fluorescent Lamps FLUORESCENT LAMP CROSS REFERENCE GE Description Osram Sylvania Description Philips Description GE Description Osram Sylvania Description Philips Description ORDER THIS GE LAMP IF YOU USE THESE LAMPS APPLIANCE ORDER THIS GE LAMP IF YOU USE THESE LAMPS ECO EXTRA-LIFE T8 SPX XP/ECO PLUS/ALTO F24T8/CW/4 F26T8/CW/4 (19W) F28T8/CW/4 (19W) F30T8/CW/4 F25T12/CW/33 F17T8/XL/SPX30/ECO F17T8/XL/SPX35/ECO F17T8/XL/SPX41/ECO F17T8/XL/SPX50/ECO F17T8/XL/SPX65/ECO F25T8/XL/SPX30/ECO F25T8/XL/SPX35/ECO F25T8/XL/SPX41/ECO F25T8/XL/SPX50/ECO F25T8/XL/SPX65/ECO F32T8/XL/SPX30/ECO F32T8/XL/SPX35/ECO F32T8/XL/SPX41/ECO F32T8/XL/SPX50/ECO F32T8/XL/SPX65/ECO F18T8/CW/K/24 F18T8/CW/K/26 F18T8/CW/K/28 F18T8/CW/K/30 F25T12/CW/33 ECOLUX® T8 SP F17T8/SP30/ECO F17T8/SP35/ECO F17T8/SP41/ECO F25T8/SP30/ECO F25T8/SP35/ECO F25T8/SP41/ECO F32T8/SP30/ECO F32T8/SP35/ECO F32T8/SP41/ECO F32T8/SP50/ECO F32T8/SP65/ECO OCTRON® FO17/730/ECO FO17/735/ECO FO17/741/ECO FO25/730/ECO FO25/735/ECO FO25/741/ECO FO32/730/ECO FO32/735/ECO FO32/741/ECO FO32/750/ECO FO32/765/ECO ECOLUX® T8 SPX F17T8/SPX30/ECO F17T8/SPX35/ECO F17T8/SPX41/ECO F25T8/SPX30/ECO F25T8/SPX35/ECO F25T8/SPX41/ECO F32T8/SPX30/ECO F32T8/SPX35/ECO F32T8/SPX41/ECO F32T8/SPX50/ECO OCTRON® FO17/830/ECO FO17/835/ECO FO17/841/ECO FO25/830/ECO FO25/835/ECO FO25/841/ECO FO32/830/ECO FO32/835/ECO FO32/841/ECO FO32/850/ECO F18T8/CW/24 F16T8/CW/26 (16W) F17T8/CW/28 (17W) F18T8/CW/30 (18W) — TL70 F17T8/TL730/ALTO F17T8/TL735/ALTO F17T8/TL741/ALTO F25T8/TL730/ALTO F25T8/TL735/ALTO F25T8/TL741/ALTO F32T8/TL730/ALTO F32T8/TL735/ALTO F32T8/TL741/ALTO F32T8/TL750/ALTO — FO17/730/XP/ECO FO17/735/XP/ECO FO17/741/XP/ECO FO25/730/XP/ECO FO25/735/XP/ECO FO25/741/XP/ECO FO32/730/XP/ECO FO32/735/XP/ECO FO32/741/XP/ECO F17T8/TL830/PLUS/ALTO F17T8/TL835/PLUS/ALTO F17T8/TL841/PLUS/ALTO F17T8/TL850/PLUS/ALTO F17T8/TL865/PLUS/ALTO F25T8/TL830/PLUS/ALTO F25T8/TL835/PLUS/ALTO F25T8/TL841/PLUS/ALTO F25T8/TL850/PLUS/ALTO F25T8/TL865/PLUS/ALTO F32T8/TL830 PLUS/ALTO F32T8/TL835 PLUS/ALTO F32T8/TL841 PLUS/ALTO F32T8/TL850 PLUS/ALTO F32T8/TL865 PLUS/ALTO 4' T8 HIGH LUMEN (HL) F32T8/XL/SPX30/HL/ECO F32T8/XL/SPX35/HL/ECO F32T8/XL/SPX41/HL/ECO F32T8/XL/SPX50/HL/ECO TL80 F17T8/TL830/ALTO F17T8/TL835/ALTO F17T8/TL841/ALTO F25T8/TL830/ALTO F25T8/TL835/ALTO F25T8/TL841/ALTO F32T8/TL830/ALTO F32T8/TL835/ALTO F32T8/TL841/ALTO F32T8/TL850/ALTO FO32/830/XPS/ALTO FO32/835/XPS/ALTO FO32/841/XPS/ALTO FO32/850/XPS/ALTO F32T8/ADV830/ALTO F32T8/ADV835/ALTO F32T8/ADV841/ALTO F32T8/ADV850/ALTO FO32/730/SS/ECO FO32/735/SS/ECO FO32/741/SS/ECO FO32/750/SS/ECO — — — — 4' T8 WATT-MISER® F32T8/SP30/IS/WM/ECO F32T8/SP35/IS/WM/ECO F32T8/SP41/IS/WM/ECO F32T8/SP50/IS/WM/ECO 4' T8 WATT-MISER® EXTRA-LIFE F32T8/XL/SP30/WM/ECO F32T8/XL/SP35/WM/ECO F32T8/XL/SP41/WM/ECO F32T8/XL/SP50/WM/ECO ECO EXTRA-LIFE T8 SP F17T8/XL/SP30/ECO F17T8/XL/SP35/ECO F17T8/XL/SP41/ECO F25T8/XL/SP30/ECO F25T8/XL/SP35/ECO F25T8/XL/SP41/ECO F32T8/XL/SP30/ECO F32T8/XL/SP35/ECO F32T8/XL/SP41/ECO FO17/830/XP/ECO FO17/835/XP/ECO FO17/841/XP/ECO FO17/850/XP/ECO FO17/865/XP/ECO FO25/830/XP/ECO FO25/835/XP/ECO FO25/841/XP/ECO FO25/850/XP/ECO FO25/865/XP/ECO FO32/830/XP/ECO FO32/841/XP/ECO FO32/835/XP/ECO FO32/850/XP/ECO FO32/865/XP/ECO — — — — — — F32T8/TL730 PLUS/ALTO F32T8/TL735 PLUS/ALTO F32T8/TL741 PLUS/ALTO — — — — F32T8/ADV830/EW/LL/ALTO F32T8/ADV835/EW/LL/ALTO F32T8/ADV841/EW/LL/ALTO F32T8/ADV850/EW/LL/ALTO 4' T8 ULTRAMAX™ 28W F28T8/SP30/UMX/ECO F28T8/SP30/UMX/ECO F28T8/SP30/UMX/ECO FO28/830/XP/SS/ECO — FO28/835/XP/SS/ECO — FO28/841/XP/SS/ECO — 4' T8 VERY LONG LIFE (SXL) F32T8/SXL/SP30/ECO F32T8/SXL/SP35/ECO F32T8/SXL/SP41/ECO FO32/830/XPS/ECO FO32/835/XPS/ECO FO32/841/XPS/ECO F32T8/TL830 PLUS/ALTO F32T8/TL830 PLUS/ALTO F32T8/TL830 PLUS/ALTO 4' T12 WATT-MISER® F40 F34/CW/RS/WM/ECO F34WW/RS/WM/ECO F34/SP30/RS/WM/ECO F34/SP35/RS/WM/ECO F34/SP41/RS/WM/ECO F34/SP50/RS/WM/ECO F34/SP65/RS/WM/ECO 4-34 F34CW/SS/ECO F34WW/SS/ECO F34/D30/SS/ECO F34/D35/SS/ECO F34/D41/SS/ECO — — See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B F34CW/RS/EW/ALTO F34WW/RS/EW/ALTO F34/SPEC30/RS/EW/ALTO F34/SPEC35/RS/EW/ALTO F34/SPEC41/RS/EW/ALTO — — Fluorescent Lamps FLUORESCENT LAMP CROSS REFERENCE (CONTINUED) GE Description Osram Sylvania Description Philips Description GE Description Osram Sylvania Description Philips Description ORDER THIS GE LAMP IF YOU USE THESE LAMPS 4' T12 WATT-MISER® F40 SPX ORDER THIS GE LAMP IF YOU USE THESE LAMPS T5 AND T5/HO (CONTINUED) F34/SPX30/RS/WM/ECO F34/SPX35/RS/WM/ECO F34/SPX41/RS/WM/ECO F24W/T5/865/ECO F39W/T5/830/ECO F39W/T5/835/ECO F39W/T5/841/ECO F39W/T5/850/ECO F39W/T5/865/ECO F54W/T5/830/ECO F54W/T5/835/ECO F54W/T5/841/ECO F54W/T5/850/ECO F54W/T5/865/ECO F49W/T5/830/ECO F49W/T5/835/ECO F49W/T5/841/ECO F49W/T5/850/ECO F49W/T5/865/ECO F80W/T5/830/ECO F80W/T5/835/ECO F80W/T5/841/ECO F80W/T5/850/ECO F80W/T5/865/ECO F34/D830/SS/ECO F34/D835/SS/ECO F34/D841/SS/ECO F34/30U/RS/EW/ALTO F34/35U/RS/EW/ALTO F34/41U/RS/EW/ALTO 8' T12 WATT-MISER® (WM) F96T12/SP30/WM/ECO F96T12/SP35/WM/ECO F96T12/SP41/WM/ECO F96T12/SP65/WM/ECO F96T12/SPX30/WM/ECO F96T12/SPX35/WM/ECO F96T12/SPX41/WM/ECO F96T12/SP30/ECO F96T12/SP35/ECO F96T12/SP41/ECO F96T12/SPX30/ECO F96T12/SPX35/ECO F96T12/SPX41/ECO F96T12/D30/SS/ECO F96T12/D35/SS/ECO F96T12/D41/SS/ECO F96T12/D65/SS (not ECO) F96T12/D830/SS/ECO F96T12/D835/SS/ECO F96T12/D841/SS/ECO F96T12/D30/ECO F96T12/D35/ECO F96T12/D41/ECO F96T12/D830/ECO F96T12/D835/ECO F96T12/D841/ECO F96T12/SPEC30/EW/ALTO F96T12/SPEC35/EW/ALTO F96T12/SPEC41/EW/ALTO — F96T12/30U/EW/ALTO F96T12/35U/EW/ALTO F96T12/41U/EW/ALTO F96T12/SPEC30/ALTO F96T12/SPEC35/ALTO F96T12/SPEC41/ALTO F96T12/SPEC30U/ALTO F96T12/SPEC35U/ALTO F96T12/SPEC41U/ALTO 8' T12 HIGH OUTPUT /WM) F96T12/CW/HO/WM/ECO F96T12/CW/HO/ SS/ECO F96T12/CW/HO/EW/ALTO — F39T5/830/HO/ALTO F39T5/835/HO/ALTO F39T5/841/HO/ALTO — — F54T5/830/HO/ALTO F54T5/835/HO/ALTO F54T5/841/HO/ALTO F54T5/850/HO/ALTO F54T5/865/HO/ALTO — — — — — F80T5/830/HO F80T5/835/HO F80T5/841/HO — — — FB34/CW/6/SS/ECO — FB40CWX/6 F48T12/CW/VHO — F72T12/CW/VHO — F96T12/CW/VHO — F48T12/CW/VHO/LT — F60T12/CW/VHO/LT F72T12/CW/VHO/LT F96T12/CW/VHO/LT FJ48T12/CW/VHO/LT — FJ72T12/CW/VHO/LT FJ96T12/CW/VHO/LT — FB34/CW/6/EW/ALTO — — F48T12/CW/VHO — F72T12/CW/VHO — F96T12/CW/VHO — F48T12/CW/VHO-O — F60T12/CW/VHO-O F72T12/CW/VHO-O F96T12/CW/VHO-O FJ48T12/CW/VHO-O FJ60T12/CW/VHO-O FJ72T12/CW/VHO-O FJ96T12/CW/VHO-O OTHER RAPID START T5 AND T5/HO F14W/T5/830/ECO F14W/T5/835/ECO F14W/T5/841/ECO F14W/T5/850/ECO F14W/T5/865/ECO F21W/T5/830/ECO F21W/T5/835/ECO F21W/T5/841/ECO F21W/T5/850/ECO F21W/T5/865/ECO F28W/T5/830/ECO F28W/T5/835/ECO F28W/T5/841/ECO F28W/T5/850/ECO F28W/T5/865/ECO F35W/T5/830/ECO F35W/T5/835/ECO F35W/T5/841/ECO F35W/T5/850/ECO F35W/T5/865/ECO F24W/T5/830/ECO F24W/T5/835/ECO F24W/T5/841/ECO F24W/T5/850/ECO — FP39/830/HO/ECO FP39/835/HO/ECO FP39/841/HO/ECO — — FP54/830/HO/ECO FP54/835/HO/ECO FP54/841/HO/ECO FP54/850/HO/ECO FP54/865/HO/ECO — — — — — FP80/830/HO FP80/835/HO FP80/841/HO — — FP14/830/ECO FP14/835/ECO FP14/841/ECO — — FP21/830/ECO FP21/835/ECO FP21/841/ECO — — FP28/830/ECO FP28/835/ECO FP28/841/ECO — FP28/865/ECO FP35/830/ECO FP35/835/ECO FP35/841/ECO — — FP24/830/HO/ECO FP24/835/HO/ECO FP24/841/HO/ECO — F96PG17/CW/WM F34CW/U/6/WM/ECO F40CW/U/3 F40CW/U/6 F48T12/CW/1500 F48PG17/CW F72T12/CW/1500 F72PG17/CW F96T12/CW/1500 F96PG17/CW F48T12/CW/1500/0 F48T12/CW/VHO/O F60T10/CW F72T12/CW/1500/0 F96T12/CW/1500/0 F48T10J/CW F60T10J/CW F72T10J/CW F96T10J/CW F14T5/830/ALTO F14T5/835/ALTO F14T5/841/ALTO — — F21T5/830/ALTO F21T5/835/ALTO F21T5/841/ALTO — — F28T5/830/ALTO F28T5/835/ALTO F28T5/841/ALTO — — F35T5/830 F35T5/835 F35T5/841 — — F24T5/830/HO/ALTO F24T5/835/HO/ALTO F24T5/841/HO/ALTO — See www.gelighting.com e-catalog for the most up-to-date product information. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage High Color Rendering. B 4-35 Ballasts GE ULTRAMAX® INSTANT START BALLASTS GE REVOLUTIONIZES LIGHTING AGAIN WITH BREAKTHROUGH TECHNOLOGY In the GE labs, our engineers have developed a breed of ballasts to make lighting systems that save more energy, are more adaptable, and deliver optimal lamp performance. The innovative, patented technology in our new UltraMax® electronic ballasts exceeds expectations, and is like nothing else available. MULTI-VOLTAGE TECHNOLOGY MEANS A SINGLE ULTRAMAX® MODEL HANDLES VOLTAGE FROM 120 THROUGH 277 UltraMax® Ballasts can virtually “read’’ the incoming voltage and adapt automatically to any voltage from 108V to 305V. The benefits of Multi-Voltage Control (MVC) are obvious: • Fewer models handle more jobs, eliminating inventory hassles. • MVC simplifies installation and eliminates guesswork at the job site. • MVC compensates for incoming voltage fluctuations or variations from unreliable power. THE ULTRAMAX® IS THE ONLY FULL LINE OF T8 BALLASTS WITH A UL TYPE CC ANTI-ARC RATING UL Type CC Rating is a stringent designation of protection against arcing in electrical devices. GE’s Arc-Guard design eliminates the damaging effects arcing can have on lamps, ballasts and sockets. HIGH EFFICIENCY DELIVERS OVER 40% ENERGY SAVINGS Ballasts are the new frontier of energy efficiency. Systems combining UltraMax® electronic ballasts and T8/WM lamps can deliver over 40% energy savings over standard electromagnetically ballasted T12 systems. Since energy costs are typically 80% of the overall cost of light, a more efficient system can pay for itself in a very short time and provide an excellent return on investment. ULTRAMAX® IS ULTRA LAMP FRIENDLY With an industry low lamp current crest factor (LCCF) of <1.5, UltraMax® ensures optimal lamp operation and maximum lamp life, which can save on lamp and maintenance costs. FULLY PARALLEL INDEPENDENT LAMP OPERATION MAKES SYSTEM EASIER TO MAINTAIN If one lamp fails, all the others in the system stay lit. That means system maintenance is easier to manage. ULTRAMAX® IS ULTRA-COOL The UltraMax® ballast's high efficiency design results in ultra-cool operation that can provide additional AC energy savings, especially during peak demand periods. A BIG IDEA IN A SMALL PACKAGE The UltraMax® ballast housing is smaller, lower-profile and lightweight. That can be a big help in retrofits. It also means future fixture designs can be more compact and streamlined. EVERY UNIT IS TESTED AND PROVEN BEFORE IT’S SHIPPED GE does 100% burn-in on every UltraMax™ ballast using our extreme open/ short test, which simulates undesirable and harsh-use situations, so you are assured of a system you can rely on right out of the box. GE SIX SIGMA QUALITY BACKED BY A FULL 5-YEAR LIMITED WARRANTY The UltraMax® balast is designed by GE’s expert engineers and custommanufactured to our exacting Six Sigma specifications, all backed by a full 5-year warranty. When used with GE T8 Lamps you also get our Total Performance System Warranty which can cover lamps up to 3 years depending on your annual usage. Contact your GE Representative for more details. A FULL FAMILY OF HIGH EFFICIENCY MULTI-VOLTAGE BALLASTS FOR ALL T8 APPLICATIONS ACTIVE CURRENT REGULATION (ACR) TECHNOLOGY IS A PATENTED ADVANTAGE The UltraMax® ballast's patented ACR modular design means individual inverter modules regulate the output current to each lamp. So, unlike conventional ballasts, if one lamp fails, the remaining lamps are not forced to operate at a higher current. This ensures optimal lamp performance. The Low watt option for Max energy savings. With a ballast factor of .77, the L line is the most energy efficient choice. It provides adequate illumination for most applications. For 1, 2, 3, and 4 T8 lamps in 2', 3', and 4' lengths. ANTI-STRIATION CONTROL FOR BETTER LIGHT QUALITY, WITH NO STRIATIONS The UltraMax® is the only line of T8 ballasts with Anti-Striation Control. This advanced technology eliminates the maintenance issues caused by striating lamps, often referred to as spiraling or swirling. This provides a flicker- and worry-free environment. The Normal light option balances efficiency and illumination. The most-used type of ballast, the N line saves energy without sacrificing lumens. A ballast factor of .87 meets most application needs. For 1, 2, 3, and 4 T8 lamps in 2', 3', 4', and 8' lengths. COMPARE THE ENERGY USE OF A THREE LAMP FIXTURE Technology Standard T12/WM System Standard Electronic T8 System UltraMax™ L System With GE F28T8 4-36 Watts 117 87 65 The choice for High light output. With a ballast factor of 1.15, UltraMax® H delivers the most lumens for maximum light or when you want more savings using fewer lamps. This is the first high-efficiency high-light output line for 2, 3 and 4 T8 lamps. See www.gelighting.com e-catalog for the most up-to-date product information. Ballasts ULTRASTART® PROGRAMMED START BALLASTS FEATURES AND BENEFITS Longer Lamp Life in Frequently Switched Applications • UltraStart® extends lamp life by 18% to greater than 200% versus instant start ballasts in frequently switched applications, saving you money in maintenance costs and replacement lamps. • Program Start ballasts are required in any applications using sensors or where extended lamp life is a primary concern. Operation of instant start ballast systems in frequently-switched applications in conjunction with automated controls (such as, but not limited to, occupancy sensor) will void lamp warranties. Same Energy Savings as High-Efficiency Instant Start Ballasts • GE UltraStart® ballasts operate at an industry high 90%+ efficiency. Traditional PS ballasts typically operate between 79–86%. Simplify Installation with Multi-Voltage Technology • The UltraStart® T5 and UltraStart® T8 XL and H ballasts incorporate MultiVoltage technology. UltraStart® can virtually “read” the incoming voltage and adapt automatically to any voltage from 108V to 305V. Fewer models handle more jobs with Multi-Voltage technology, and it eliminates guess work at the job site. Multi-Voltage BallastsControl (MVC) also compensates for incoming voltage fluctuations or variations from unreliable power. Lower Maintenance Costs with Parallel Mode Operation • Most PS ballasts operate in series mode, meaning if one bulb goes out, they all go out. GE UltraStart® T8 ballasts operate in parallel mode, meaning if one bulb goes out, others stay on. Fast Starting Time • GE UltraStart® T8 ballasts start in visually the same time as instant start ballasts (less than 0.7 seconds)—a significant improvement versus Product Code Description ULTRAMAX® 49706 49771 23939 49775 47548 49707 47546 49772 31052 23940 49776 47549 49708 31055 49773 31053 23941 49777 47550 49709 47547 49774 31054 23942 traditional PS ballasts. An important feature when using sensors and the annoying delay of waiting for the lights to turn on with traditional PS ballasts. Complies with (RoHS) Restrictions of Hazardous Materials Standards. GE LAMP LIFE RANGE—INSTANT START VS. PROGRAMMED START** GE lamp life studies have shown that lamp life is up to 20 times longer in rapid cycle testing. Lamp life tests have demonstrated 111,000 to 243,000 starts on F32T8 lamps with GE UltraStart® ballasts as opposed to only 7,000 to 13,000 starts with standard instant start ballasts. UltraStart® maximizes lamp life in frequently switched applications and where lamp life is a primary concern. GE UltraStart® ballasts and lamps provide guaranteed performance with the GE Total System Limited Warranty. **GE 2004–2005 lamp testing @ industry standard B50 rapid cycle testing. Starting Method Ballast Factor Lamp Wiring Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Low Normal Normal High High Low Low Normal Normal Normal High High Low Low Normal Normal Normal High High Low Low Normal Normal Normal Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Application Package Type Units Per Carton INSTANT START MULTI-VOLTAGE HIGH EFFICIENCY GE132MAX-L/ULTRA GE132MAX-N/ULTRA GE132MAX-N-IP GE232MAX-H/ULTRA GE232MAX-H-42T GE232MAX-L/ULTRA GE232MAX-L-42T GE232MAX-N/ULTRA GE232MAX-N-42T GE232MAX-N-IP GE332MAX-H/ULTRA GE332MAX-H-42T GE332MAX-L/ULTRA GE332MAX-L-42T GE332MAX-N/ULTRA GE332MAX-N-42T GE332MAX-N-IP GE432MAX-H/ULTRA GE432MAX-H-42T GE432MAX-L/ULTRA GE432MAX-L-42T GE432MAX-N/ULTRA GE432MAX-N-42T GE432MAX-N-IP 1- F32T8 120 to 277 “L” .77BF 1- F32T8 120 to 277”N” .87 BF 1- F32T8 120 to 277”N” .87 BF I-Pack 4/carton 2 or 1- F32T8 120 to 277 “H” 1.15 BF 2 or 1- F32T8 120 to 277”H” 1.15 BF Pallet Pack 2 or 1- F32T8 120 to 277 “L” .77 BF 2 or 1- F32T8 120 to 277 “L” .77 BF Pallet Pack 2 or 1- F32T8 120 to 277 “N” .87 BF 2 or 1- F32T8 120 to 277 “N” .87 BF Pallet Pack 2 or 1- F32T8 120 to 277 “N” .87 BF I-Pack 4/carton 3 or 2- F32T8 120 to 277 3 or 2- F32T8 120 to 277 “H” 1.15 BF Pallet Pack 3 or 2- F32T8 120 to 277 “l” .77 BF 3 or 2- F32T8 120 to 277 “l” .77 BF Pallet Pack 3 or 2- F32T8 120 to 277 “N” .87 BF 3 or 2- F32T8 120 to 277 “N” .87 BF Pallet Pack 3 or 2- F32T8 120 to 277 “N” .87 BF I-Pack 4/carton 4 or 3- F32T8 120 to 277 “H” 1.15 BF 4 or 3- F32T8 120 to 277 “H” 1.15 BF Pallet Pack 4 or 3- F32T8 120 to 277 “L” .77 BF 4 or 3- F32T8 120 to 277 “L” .77 BF Pallet Pack 4 or 3- F32T8 120 to 277 “N” .87 BF 4 or 3- F32T8 120 to 277 “N” .87 BF Pallet Pack 4 or 3- F32T8 120 to 277 “N” .87 BF I-Pack 4/carton See www.gelighting.com e-catalog for the most up-to-date product information. Standard Standard DIY Standard Pallet Pack Standard Pallet Pack Standard Pallet Pack DIY Standard Pallet Pack Standard Pallet Pack Standard Pallet Pack DIY Standard Pallet Pack Standard Pallet Pack Standard Pallet Pack DIY 10 10 4 10 420 10 420 10 420 4 10 420 10 420 10 420 4 10 420 10 420 10 420 4 4-37 Ballasts Product Code Description Application Ballast Factor Lamp Wiring Package Type Units Per Carton Instant Start Instant Start Instant Start Normal Normal Normal Parallel Parallel Parallel Standard Standard DIY 10 10 4 Programmed Start Normal Parallel Standard 10 Programmed Start Normal Parallel Pallet Pack 420 Programmed Start Programmed Start Normal Normal Parallel Parallel Standard Pallet Pack 10 420 Programmed Start High Parallel Standard 10 Programmed Start High Parallel Pallet Pack 420 Programmed Start Programmed Start Programmed Start Ultra Low Ultra Low Normal Parallel Parallel Parallel Standard Pallet Pack Standard 10 420 10 Programmed Start Normal Parallel Pallet Pack 420 Programmed Start Normal Parallel Standard 10 Programmed Start Normal Parallel Pallet Pack 420 Programmed Start High Parallel Standard 10 Programmed Start High Parallel Pallet Pack 420 Programmed Start Programmed Start Programmed Start Ultra Low Ultra Low Normal Parallel Parallel Parallel Standard Pallet Pack Standard 10 420 10 Programmed Start Normal Parallel Pallet Pack 420 Programmed Start Normal Parallel Standard 10 Programmed Start Normal Parallel Pallet Pack 420 Programmed Start High Parallel Standard 8 Programmed Start High Parallel Pallet Pack 420 Rapid Start Rapid Start Normal Normal Series Series Standard Standard 6 6 Programmed Start Programmed Start Normal Normal Series-Parallel Standard Series-Parallel Pallet Pack Starting Method ULTRAMAX™ INSTANT START MULTI-VOLTAGE HIGH EFFICIENCY (CONTINUED) 49766 49767 23954 GE159MAX-N/ULTRA GE259MAX-N/ULTRA GE259MAX-N-IP 1- F96T8 120 to 277 2 or 1- F96T8 120 to 277 “N” .87 BF 2 or 1- F96T8 120 to 277 “N” .87 BF I-Pack 4/carton ULTRASTART™ T8 PROGRAM START 29621 GE-232-120-PS-N 29630 GE-232-120PS-N-T 29622 29632 GE-232-277-PS-N GE-232-277PS-N-T 29675 GE-232-MVPS-H 29651 GE-232-MV-PS-H-T 29671 29665 29623 GE-232-MVPS-XL GE-232-MVPS-XL-T GE-332-120-PS-N 29633 GE-332-120PS-N-T 29624 GE-332-277-PS-N 29634 GE-332-277PS-N-T 29676 GE-332-MVPS-H 29656 GE-332-MV-PS-H-T 29672 29666 29625 GE-332-MVPS-XL GE-332-MVPS-XL-T GE-432-120-PS-N 29635 GE-432-120PS-N-T 29627 GE-432-277-PS-N 29650 GE-432-277PS-N-T 29678 GE-432-MVPS-H 29657 GE-432-MV-PS-H-T 2 F32T8 120V Normal Light .87 BF<10% THD UltraStart 2 F32T8 120V Normal Light .87 BF<10% THD UltraStart 2 F32T8 277V Normal Light .87 BF<10% THD 2 F32T8 277V Normal Light .87 BF<10% THD UltraStart 2 F32T8 120V-277V High Light 1.15 BF<10% THD UltraStart 2 F32T8 120V-277V High Light 1.15 BF<10% THD UltraStart 2 F32T8 120V-277V Ultra Low Watt .60 BF<10% THD 2 F32T8 120V-277V Ultra Low Watt .60 BF<10% THD 3 F32T8 120V Normal Light .87 BF<10% THD UltraStart 3 F32T8 120V Normal Light .87 BF<10% THD UltraStart 3 F32T8 277V Normal Light .87 BF<10% THD UltraStart 3 F32T8 277V Normal Light .87 BF<10% THD UltraStart 3 F32T8 120V-277V High Light 1.15 BF<10% THD UltraStart 3 F32T8 120V-277V High Light 1.15 BF<10% THD UltraStart 3 F32T8 120V-277V Ultra Low Watt .60 BF<10% THD 3 F32T8 120V-277V Extra Low Watt .60 BF<10% THD 4 F32T8 120V Normal Light .87 BF<10% THD UltraStart 4 F32T8 120V Normal Light .87 BF<10% THD UltraStart 4 F32T8 277V Normal Light .87 BF<10% THD UltraStart 4 F32T8 277V Normal Light .87 BF<10% THD UltraStart 4 F32T8 120V-277V High Light 1.15 BF<10% THD UltraStart 4 F32T8 120V-277V High Light 1.15 BF<10% THD UltraStart RAPID START T12 HIGH OUTPUT 80162 80163 B295SR120HP B295SR277HP 2- F96T12HOES RS 120 2- F96T12HOES RS 277 ULTRASTART® T5 PROGRAM START 29726 29717 4-38 GE454MVPSN1 GE454MVPSN1-B 4 or 2- F54T5HO 120 to 277 UltraStart PRS 4 or 2- F54T5HO 120 to 277 UltraStart PRS Pallet Pack See www.gelighting.com e-catalog for the most up-to-date product information. 12 420 Ballasts Product Code Description Application Ballast Factor Lamp Wiring Package Type Units Per Carton Programmed Start Programmed Start Programmed Start Programmed Start Normal Normal Normal Normal Series Series Series Series Standard Standard Standard Standard 10 10 10 10 Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Standard Pallet Pack Standard Pallet Pack Standard Pallet Pack Standard Pallet Pack Standard Pallet Pack Standard Pallet Pack Standard Pallet Pack Standard Pallet Pack Standard Pallet Pack Standard Pallet Pack 10 840 10 840 10 840 10 840 10 840 10 840 10 840 10 840 10 840 10 840 Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Instant Start Normal Normal High High Low Normal Normal High High Low Low Normal Normal High High Low Low Normal Normal Normal Normal Normal Normal Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Parallel Standard Pallet Pack Standard Pallet Pack Standard Standard Pallet Pack Standard Pallet Pack Standard Standard Standard Pallet Pack Standard Pallet Pack Standard Pallet Pack Standard Pallet Pack Standard Pallet Pack Standard Pallet Pack 10 420 10 420 10 10 420 10 420 10 420 10 420 10 420 10 420 10 420 10 420 10 420 Starting Method T5 PROGRAMMED START MULTI-VOLT 120V - 277V 47534 47536 47540 47542 B224PUNV-COG1C B228PUNV-C0G1C B239PUNV-DOG1C B254PUNV-DGE1C 2- F24T5HO PRS UNV 50/60 Hz 2- F28T5 PRS UNV 50/60 Hz 2- F39T5HO PRS UNV 50/60 Hz 2- F54T5HO PRS UNV 50/60 Hz PROLINE™ T8 INSTANT START 23680 24161 23681 24162 23671 24163 23672 24164 23673 24165 23674 24166 23675 24167 23676 24168 23677 24169 23678 24170 GE-132-120-N GE-132-120-N-84T GE-132-277-N GE-132-277-N-84T GE-232-120-N GE-232-120-N-84T GE-232-277-N GE-232-277-N-84T GE-332-120-N GE-332-120-N-84T GE-332-277-N GE-332-277-N-84T GE-432-120-N GE-432-120-N-84T GE-432-277-N GE-432-277-N-84T GE-259-120-N GE-259-120-N-84T GE-259-277-N GE-259-277-N-84T 1 F32T8 120V “N”.87 BF 1 F32T8 120V “N”.87 BF Pallet Pack 1 F32T8 277V “N”.87 BF 1 F32T8 277V “N”.87 BF Pallet Pack 2 or 1 - F32T8 120V “N”.87 BF 2 or 1- F32T8 120V “N”.87 BF Pallet Pack 2 or 1- F32T8 277V “N”.87 BF 2 or 1- F32T8 277V “N”.87 BF Pallet Pack 3 or 2- F32T8 120V “N”.87 BF 3 or 2- F32T8 120V “N”.87 BF Pallet Pack 3 or 2- F32T8 277V “N”.87 BF 3 or 2- F32T8 277V “N”.87 BF Pallet Pack 4 or 3- F32T8 120V “N”.87 BF 4 or 3- F32T8 120V “N”.87 BF Pallet Pack 4 or 3- F32T8 277V “N”.87 BF 4 or 3- F32T8 277V “N”.87 BF Pallet Pack 2 or 1 F96T8 120v Normal Light .87 BF<10%THD 2 or 1- F96T8 120v “N”.87 BF Pallet Pack 2 or 1- F96T8 277v “N”.87 BF 2 or 1- F96T8 277v “N”.87 BF Pallet Pack MULTI-VOLT PROLINE™ T8 INSTANT START 120-277V 30189 30268 30198 30275 30247 30191 30269 30199 30296 30255 30309 30192 30270 30219 30303 30262 30310 30193 30271 30195 30274 30194 30272 GE-132-MV-N GE-132-MV-N-42T GE-232-MV-H2 or GE-232-MV-H-42T GE-232-MV-L GE-232-MV-N GE-232-MV-N-42T GE-332-MV-H GE-332-MV-H-42T GE-332-MV-L GE-332-MV-L-42T GE-332-MV-N GE-332-MV-N-42T GE-432-MV-H GE-432-MV-H-42T GE-432-MV-L GE-432-MV-L-42T GE-432-MV-N GE-432-MV-N-42T GE-159-MV-N GE-159-MV-N-42T GE-259-MV-N GE-259-MV-N-42T 1- F32T8 120 to 277 “N”.87 BF 1- F32T8 120 to 277 “N”.87 BF Pallet Pack 1- F32T8 120 to 277 “H” 1.15 BF 2 or 1- F32T8 120 to 277 “H” 1.15 BF Pallet Pack 2 or 1- F32T8 120 to 277 “L”.77 BF 2 or 1- F32T8 120 to 277 “N”.87 BF 2 or 1- F32T8 120 to 277 “N”.87 BF Pallet Pack 3 or 2- F32T8 120 to 277 “H” 1.15 BF 3 or 2- F32T8 120 to 277 “H” 1.15 BF Pallet Pack 3 or 2- F32T8 120 to 277 3 or 2- F32T8 120 to 277 3 or 2- F32T8 120 to 277 “N”.87 BF 3 or 2- F32T8 120 to 277 “N”.87 BF Pallet Pack 4 or 3- F32T8 120 to 277 “H” 1.15 BF 4 or 3- F32T8 120 to 277 “H” 1.15 BF Pallet Pack 4 or 3- F32T8 120 to 277 4 or 3- F32T8 120 to 277 4 or 3- F32T8 120 to 277 “N”.87 BF 4 or 3- F32T8 120 to 277 “N”.87 BF Pallet Pack 1- F96T8 120 to 277 “N”.87 BF 1- F96T8 120 to 277 “N” .87 BF Pallet Pack 2 or 1- F96T8 120 to 277 “N”.87 BF 2 or 1- F96T8 120 to 277 “N”.87 BF Pallet Pack See www.gelighting.com e-catalog for the most up-to-date product information. 4-39 Ballasts Product Code Description Ballast Factor Lamp Wiring Instant Start Instant Start Normal Normal Parallel Parallel Standard Pallet Pack 10 420 Rapid Start Rapid Start Normal Normal Parallel Parallel Standard DIY 10 4 Application Package Type Units Per Carton Starting Method MULTI-VOLT PROLINE™ T8 INSTANT START 120-277V (CONTINUED) 30176 30187 GE-286-HO-MV-N GE-286-HO-MV-N-P 2 or 1- F96T8HO IS 120 to 277 “N”.87 BF 2 or 1- F96T8HO IS 120 to 277 “N”.87 BF MULTI-VOLT PROLINE™ T12 ELECTRONIC T12 120-277V 24107 24773 GE-240-RS-MV-N GE-240RS-MV-N-DIY 24109 24774 GE-340-RS-MV-N GE-340RS-MV-N-DIY 24776 24108 GE-260IS-MV-N-DIY GE-260-IS-MV-N 2 or 1- F40 or F34T12 Rapid Start 120 to 277 “N” BF 2 or 1- F40 or F34T12 RS 120 to 277 I-Pack 4/carton 3 or 2- F40 or F34T12 Rapid Start 120 to 277 3 or 2- F40 or F34T12 RS 120 to 277 I-Pack 4/carton 2 or 1- F96T12 IS 120 to 277; I-Pack 4/carton 2 or 1- F96T12 Instant Start 120 to 277 Rapid Start Rapid Start Normal Normal Parallel Parallel Standard DIY 10 4 Instant Start — Normal High Parallel Parallel DIY Standard 4 6 2 F96T8 IS 120 60 HBEX 2 F96T8 IS 277 60 HBCX 3- F32T8 IS 347 60Hz <10% THD “N” BF 3- F32T8 IS 347 <10% THD “L” BF Instant Start Instant Start Instant Start Instant Start High High Normal Low Parallel Parallel Parallel Parallel Standard Standard Standard Standard 6 6 10 10 1- F32T8 DIM 100 to 5% RS 120 2- F32T8 DIM 100 to 5% RS 120 2- F32T8 Switch 100 / 50% RS 277 2- F32T8 DIM 100 to 5% RS 277 3- F32T8 DIM 100 to 5% RS 120 3- F32T8 DIM 100 to 5% RS 277 Rapid Start Rapid Start Rapid Start Rapid Start Rapid Start Rapid Start Normal Normal Normal Normal Normal Normal Series Series Series Series Series Series Standard Standard Standard Standard Standard Standard 10 10 10 10 10 10 Preheat Normal Series DIY 10 Trigger Start Normal Series DIY 4 Rapid Start Normal Series DIY 4 Rapid Start Normal Series DIY 4 Rapid Start Normal Series Individual Pack 10 Instant Start Instant Start Instant Start Preheat Normal Normal Normal Normal Series Series Series Series DIY Individual Pack Individual Pack Individual Pack 4 6 6 20 Rapid Start Normal Series DIY 4 Rapid Start Rapid Start Rapid Start Rapid Start Trigger Start Normal Normal Normal Normal Normal Series Series Series Series Series Individual Pack DIY Individual Pack Standard DIY 10 4 10 4 4 Rapid Start Rapid Start Rapid Start Mod. Rapid Start Normal Normal Normal Normal Series Series Series Series DIY Individual Pack Individual Pack DIY 4 10 10 4 OTHER INSTANT START 80148 80149 80136 80277 B259I120RHH B259I277RHH B332I347HP B332I347HPL T8 DIMMING 80353 80355 80362 80356 80357 80358 B132R120V5 B232SR120V5 B232SR277S50 B232SR277V5 B332SR120V5 B332SR277V5 MAGNETIC T12, T8, CIRCLELINE® BALLASTS 89711 GEM120-PH-120-DIY 89712 GEM120-TC-120-DIY 89714 GEM140-HRS-120-DIY 89709 GEM140-RS-120-DIY 86158 GEM140-RS-277-IP 89719 86372 86381 86231 GEM196-IS-120-DIY GEM196-IS-120-IP GEM196-IS-277 GEM1F4T5-PH-120 89720 GEM1FC16T9-RS-120 86132 89722 86227 89717 80819 GEM1FC16T9-RS-120-IP GEM1FC8T9-RS-120-DIY GEM1FC8T9-RS-120-IP GEM1FC12T9-RS-120 GEM220-TS-120-DIY 80644 87125 87130 89710 GEM230-RS-120 GEM232T8-RS-120 GEM232T8-RS-277 GEM240-HRS-120-DIY 4-40 1- F20T12 F15T8 F1512 120V Magnetic Ballast(200H2) 1- F20T12 F15T8 F15T12 F14T12 120V Magnetic Ballast (546BTCP) 1- F40T12 F40T12 120V Magnetic Ballast (412LSLHTCP) 1- F40T12 F30T12 F48/25W 120V Magnetic Ballast (413CTCP) 2- F40T12, F40T10, 120V, Magnetic Ballast, (446LSLHTCP) 1- F96T12 120V Magnetic Ballast (822BRTCP) 1- F96T12 IS 120 Magnetic Ballast (822BRTCP) 1- F96T12 IS 277 Magnetic Ballast (828BRTCP) 1- F20T12, F15T8, F15T12, F14T12, 120V, Magnetic (546BTCP) 2- FC12T9 FC16T9 FC8T9 FC12T9 120V Magnetic (726VLHWSTCP) 1- F96T12, IS, 277V, Magnetic Ballast (828BRTCP) 1- FC8T9 RS 120V Magnetic Ballast (547RSWSTCP) 1- FC8T9 RS 120V Magnetic Ballast (547RSWSTCP) 2 FC12T9 RS 120V Magnetic Ballast (449LRWSTCP) 2- F20T12 F15T8 F15T12 F14T12 120V Magnetic Ballast (447LRVLHTCP) 2- F30T12 120V Magnetic Ballast (573LTCP) 2- F32T8 RS 120V Magnetic Ballast (M232SR120C) 2- F32T8 RS 277V Magnetic Ballast (M232SR277C) 2- F40T12 F40T12 120V Magnetic Ballast (420LTCP) See www.gelighting.com e-catalog for the most up-to-date product information. Ballasts Product Code Description MAGNETIC T12, T8, Ballast Factor Lamp Wiring Instant Start Normal Series Individual Pack 6 Rapid Start Normal Series Pallet Pack 72 Rapid Start Rapid Start Rapid Start Normal Normal Normal Series Series Series DIY Individual Pack DIY 6 10 4 Rapid Start Rapid Start Rapid Start Rapid Start Normal Normal Normal Normal Series Series Series Series Individual Pack Standard Individual Pack DIY 10 10 4 2 Rapid Start Normal Series DIY 4 Rapid Start Instant Start Instant Start Instant Start Instant Start Instant Start Normal Normal Normal Normal Normal Normal Series Series Series Series Series Series Individual Pack Pallet Pack DIY Individual Pack DIY Individual Pack 4 48 4 6 4 6 Rapid Start Rapid Start Rapid Start Rapid Start Rapid Start Rapid Start Normal Normal Normal Normal Normal Normal Series Series Series Series Series Series Individual Pack Individual Pack Individual Pack Individual Pack Individual Pack Individual Pack 4 4 2 2 2 2 Rapid Start Rapid Start Rapid Start Normal Normal Normal Series Series Series Individual Pack Individual Pack Individual Pack 2 2 2 Preheat Rapid Start Rapid Start Preheat Preheat Preheat Normal Normal Normal Normal Normal Normal Series Series Series Series Series Parallel Standard Standard Standard Standard Standard Standard 20 10 10 20 10 10 Bottom Exit Prog. Rapid Start Bottom Exit w/ Studs Prog. Rapid Start Prog. Rapid Start Normal Normal Normal Series Series Series Individual Pack Individual Pack Individual Pack 10 10 10 Bottom Exit Prog. Rapid Start Bottom Exit w/ Studs Prog. Rapid Start Prog. Rapid Start Normal Normal Normal Series Series Series Individual Pack Individual Pack Individual Pack 10 10 10 Prog. Rapid Start Instant Start Instant Start Normal Normal Normal Series Series Series Individual Pack Individual Pack Individual Pack 10 10 10 Application CIRCLELINE® 86206 GEM240-IS-277-IP 89707 GEM240-RS-120-DIY 46958 86139 89713 GEM240-RS-120-DIY GEM240-RS-120-IP GEM240-RS-277-DIY 86124 86341 86176 89718 GEM240-RS-277-IP GEM240-RS-220 GEM272HO-RS-120 GEM296HO-RS-120-DIY 86164 GEM296HO-RS-120-IP 86171 89708 46965 86360 89715 86379 GEM296HO-RS-2772 GEM296-IS-120-DIY2 GEM296-IS-120-DIY2 GEM296-IS-120-IP2 GEM296-IS-277-DIY2 GEM296-IS-277-IP2 Package Type Units Per Carton Starting Method BALLASTS (CONTINUED) 2- F40T12 F40T10 IS 277V Magnetic Ballast (532BRTCP) 2- F40T12 F40T10 120V Magnetic Ballast (446LSLHTCP) 2 F40T12 F40T10 120V Magnetic Ballast 2- F40T12 RS 120V Magnetic Ballast (446LSLHTCP) 2- F40T12 F40T10 277V Magnetic Ballast (443LSLHTCP) 2- F40T12 RS 277V Magnetic Ballast (443LSLHTCP) 2- F40T12 F40T10 220V Magnetic Ballast (754LTCP) 2- F72T12HO RS 120V Magnetic Ballast (490XLHTCP) 2 -F96T12HO F72T12HO 120V Magnetic Ballast (480SLHTCP) 2- F96T12HO F72T12HO RS 120V Magnetic Ballast (480SLHTCP) F96T12 HO RS 277V Magnetic Ballast (487SLHTCP) F96T12 IS 120V Magnetic Ballast (806SLHTCP) F96T12 IS 120V Magnetic Ballast 60 HBCB F96T12 IS 120V Magnetic Ballast (806SLHTCP) F96T12 IS 277V Magnetic Ballast (827SLHTCP) F96T12 IS 277V Magnetic Ballast (827SLHTCP) MAGNETIC T12 SIGN BALLASTS 88921 88931 88934 88936 88939 88940 USB-0412-12-IP USB-0816-14-IP USB-1632-24-IP USB-1024-14-IP USB-2036-46-IP USB-2048-46-IP 04 to 12 foot 08 to 16 feet 16 to 32 feet 10 to 24 feet 20 to 36 feet 20 to 48 feet 1 to 2 lamps 1 to 4 lamps 2 to 4 lamps 1 to 4 lamps 4 to 6 lamps 4 to 6 lamps MAGNETIC T12 SIGN MAX-3 SERIES BALLASTS 88918 88919 88920 USB-0218-16-IP USB-1048-16-IP USB-1232-16-IP Max 3 02 to 18 feet 1 to 6 lamps Max 3 10 to 48 feet 1 to 6 lamps Max 3 12 to 32 feet 1 to 6 lamps MAGNETIC BALLASTS FOR COMPACT FLUORESCENT LAMPS 87533 87623 87625 87634 87655 87700 GEM1CF13-PH-120 GEM2FT36-RS-120 GEM2FT40-RS-120 GEM1CF579-PH-277 GEM2CF13-PH-277 GEM2CF24-PH-277 1- CFT/Q13W/GX23 Pre Heat 120 (4111H2P) 2- FT36W/2G11 RS 120 (4150P) 2- FT40W/2G11RS RS 120 (4152P) 1- CFT579Q9W/G23 Pre Heat 277 (4205F2P) 2- CFT/Q13W/GX23 Pre Heat 277 (4214PBES) 2- CFQ26W/G24d Pre Heat 277 (4226PBES) ELECTRONIC BALLASTS FOR COMPACT FLUORESCENT LAMPS 80669 80671 80673 C213UNVBE-IP C213UNVBES-IP C213UNVSE-IP 80675 80677 80679 C218UNVBEIP C218UNVBES-IP C218UNVSE-IP 80683 80680 80681 C240PUNVHP-B-IP C240SI120RH-IP C240SI277RH-IP 2 or 1- CFQ13W/G24q PS UNV 2 or 1- CFQ13W/G24q PS UNV 2 or 1- CFQ13W/G24q PS UNV Side Exit (most common) 2 or 1- CFQ18W/G24q PS UNV 2 or 1- CFQ18W/G24q PS UNV 2 or 1- CFQ18W/G24q PS UNV Side Exit (most common) 2 or 1- FT40W2G11 PS UNV 2- FT40W/2G11 IS 120 2- FT40W/2G11- IS 277 See www.gelighting.com e-catalog for the most up-to-date product information. 4-41 Ballasts Product Code Description Application Starting Method Ballast Factor Lamp Wiring Package Type Units Per Carton ELECTRONIC BALLASTS FOR COMPACT FLUORESCENT LAMPS (CONTINUED) 47506 C242UNVBES-IP 47509 80685 80687 80689 80690 80691 C242UNVSE-IP C2642UNVBE-IP C2642UNVBES-IP C2642UNVSE-IP C340SI120RH-IP C340SI277RH-IP 2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/ Studs 2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Side Exit 2 or 1- CF 26 42w PS UNV 2 or 1- CF 26 42w PS UNV 1/2 CF 26 42W PS UNV 60 HBXX 3- FT40W/2G11 IS 120 3- FT40W/2G11 IS 277 Prog. Rapid Start Normal Series Individual Pack 10 Prog. Rapid Start Prog. Rapid Start Prog. Rapid Start Prog. Rapid Start Instant Start Instant Start Normal Normal Normal Normal Normal Normal Series Series Series Series Series Series Individual Pack Individual Pack Individual Pack Individual Pack Individual Pack Individual Pack 10 10 10 10 10 10 1- 250 to 400w UltraMax HID Electronic 208-277 50-60Hz M155, M154, M153, M131 Electronic Standard Pack 1 ANSI Lamp/ Ballast Circuit Type Frame Size (H x L) M110 M98 M98 M90, M92, M140 M90, M92, M140 M102, M142 M102, M142, M107 M57, H39, M107 M57, H39, M109 M58, H37 M58, H37 HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF CWA CWA CWA CWA 3x4 3x4 3x4 4.25x5.75 3x4 3x4 3x4 3x4 3x4 3x4 3x4 Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit 6 6 6 6 6 6 6 6 6 6 6 M58, H37 M59, H33 M59, H33 M59, H33 M59, H33 M58, H37 M58, H37 M47, H36 M47, H36 M47, H36 M48 M48 CWA CWA CWA CWA CWA CWA CWA CWA CWA CWA CWA CWA 3x4 4.25x4.75 4.25x4.75 4.25x4.75 4.25x4.75 4.25x4.75 4.25x4.75 4.25x5.75 4.25x5.75 4.25x5.75 4.25x5.75 4.25x5.75 Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit 1 3 1 3 3 3 1 2 2 2 2 2 CWA CWA CWA CWA CWA CWA CWA CWA RX-NPF CWA 3x4 3x4 4.25x4.75 4.25x4.75 4.25x4.75 4.25x4.75 4.25x4.75 4.25x4.75 3.75x4.5 4.25x4.75 Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit 6 6 3 3 3 3 3 3 3 3 ELECTRONIC HID 29377 Product Code GE-MH-250-400-MA Description Application* Package Type Units Per Carton DISTRIBUTOR REPLACEMENT BALLAST KITS - METAL HALIDE 86824 86847 86839 86675 86667 86718 86711 86741 87210 86765 87211 M50MLTLC3M500K M70MLTLC3M500K M7048TLC3M500K M100MLTLC3M500K M10048TLC3M500K M150MLTLC3M500K M15048TLC3M500K M175MLTAC3M500K M175ML5AC3M500K M250MLTAC3M500K M250ML5AC3M500K 49763 87212 49742 86814 86803 86808 49745 86650 86655 87213 86698 86693 M250ML5AC3M555K M250ML5AC4M500K M250ML5AC4M555K M400MLTAC4M500K M40048TAC4M500K M400ML5AC4M500K M400ML5AC4M555K M100048TAC5M500K M1000MLTAC5M500K M1000ML5AC5M500K M1500MLTAC5M500K M150048TAC5M500K 1- 50w MH M110 or M148 Quad 1- 70w MH M 98 or M143 Quad 1- 70w MH M 98 or M143 480 1- 100w MH M 90 or M140 Quad 1- 100w MH M 90 or M140 480 1- 150w MH M102 or M142 Quad 1- 150w MH M102 or M142 480 1- 175w MH M 57 or H 39 Quad 1- 175w MH M 57 or H 39 Multi-5 for all voltages 1- 250w MH M 58 or H 37 Quad 1- 250w MH M 58 or H 37 Multi-5 small standard frame 1- 250w MH M 58 or H 37 Multi-5 with Lamp (555K) 1- 250w MH M 58 or H 37 Multi-5 large frame 1- 250w MH M 58 or H 37 Multi-5 with Lamp (555K) 1- 400w MH M 59 or H 33 Quad 1- 400w MH M 59 or H 33 480 1- 400w MH M 59 or H 33 Multi-5 for all voltages 1- 400w MH M 59 or H 33 Multi-5 with Lamp (555K) 1- 1000w MH M 47 or H 36 480 1- 1000w MH M 47 or H 36 Quad 1- 1000w MH M 47 or H 36 Multi-5 for all voltages 1- 1500w MH M 48 Quad 1- 1500w MH M 48 480 DISTRIBUTOR REPLACEMENT BALLAST KITS - PULSE START METAL HALIDE 86876 86885 86926 86935 86952 86968 86959 86984 42692 86999 4-42 P17548TAC3M500K P175MLTAC3M500K P25048TAC4M500K P250MLTAC4M500K P32048TAC4M500K P320TRIAC4M502K P320MLTAC4M500K P350MLTAC4M500K P350277RCEM500K P40048TAC4M500K 1- 175w 1- 175w 1- 250w 1- 250w 1- 320w 1- 320w 1- 320w 1- 350w 1- 350w 1- 400w PS PS PS PS PS PS PS PS PS PS M137 or M152 480 M152,M137 M137 or M 152 Quad M153, M 137 M138 or M153 480 M153, M138 M138 or M153 Quad M153, M138 M132 or M154 480 M154, M132 M132 or M154 TRI-Voltage 120 277 347 M154, M132 M132 or 154 Quad M154, M132 M131 Quad M131 M131 277 Reactor M131 M135 now M155 480 M155,M135 See www.gelighting.com e-catalog for the most up-to-date product information. Ballasts Product Code Description Application* ANSI Lamp/ Ballast Circuit Type Frame Size (H x L) Package Type Units Per Carton DISTRIBUTOR REPLACEMENT BALLAST KITS - PULSE START METAL HALIDE (CONTINUED) 87008 46934 46936 P400MLTAC4M500K P750MLTAC5M500K P75048TAC5M500K 1- 400w PS M135 or M155 Quad 1-750w PS M149 Quad 1-750w PS M149 480 M155,M135 M149 M149 CWA CWA CWA 4.25x4.75 4.25x5.75 4.25x5.75 Distributor Kit Distributor Kit Distributor Kit 3 2 2 S68 S62 S62 S54 S54 S55 S55 S50 S50 S50 S51 S51 S51 S52 S51 S51 S51 S52 S52 S52 HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF CWA CWA CWA CWA CWA CWA CWA CWA CWA CWA CWA CWA CWA 3x4 3x4 3x4 3x4 3x4 3x4 3x4 4.25x4.75 4.25x4.75 4.25x4.75 4.25x4.75 4.25x5.75 4.25x5.75 4.25x4.75 4.25x4.75 4.25x4.75 4.25x5.75 4.25x5.75 4.25x5.75 4.25x5.75 Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit Distributor Kit 6 6 6 6 6 6 6 3 1 3 3 2 2 1 3 3 2 2 2 2 1- 100w H36 Quad 1- 175w H39 Quad 1- 400w H39 Quad H38, H44 H39 H33 CWA CWA CWA 3x4 3x4 4.25x4.75 Distributor Kit Distributor Kit Distributor Kit 6 6 3 1- 70w M85 120/277 Enclosed & Potted 1- 70w M98 120/277 Enclosed & Potted 1- 100w M90 120/277 Enclosed & Potted 1- 175w M57 120/277 Enclosed & Potted 1- 250w M58 120/277 Enclosed & Potted 1- 400w M59 120/277 Enclosed & Potted F-can 1- 400w M59 120/277 Enclosed & Potted M85 M98 M90 M57, H39 M58, H37 M59, H33 M59, H33 HX-HPF HX-HPF HX-HPF CWA CWA CWA CWA 0 0 0 0 0 0 0 Standard Standard Standard Standard Standard Standard Standard 4 4 4 2 2 2 4 1- 70w S62 120 Reactor-NPF 1- 70w S62 120/277 E & P F-can built-in starter 1- 150w S55 120 Reactor-NPF S62 S62 S55 R-NPF HX-HPF R-NPF 0 0 0 Standard Standard Standard 6 4 6 DISTRIBUTOR REPLACEMENT BALLAST KITS - HIGH PRESSURE SODIUM 87152 86587 86456 87074 87068 87094 87087 87214 49757 87121 87164 87175 87217 49758 87215 87198 87206 87056 87048 87218 S50MLTLC3M500K S70MLTLC3M500K S7048TLC3M500K S100MLTLC3M500K S10048TLC3M500K S150MLTLC3M500K S15048TLC3M500K S250ML5AC4M500K S250ML5AC4M555K S250MLTAC4M500K S400MLTAC4M500K S400MLTAC5M500K S400ML5AC5M500K S400ML5AC4M555K S400ML5AC4M500K S40048TAC4M500K S40048TAC5M500K S1000MLTAC5M500K S100048TAC5M500K S1000ML5AC5M500K 1- 50w S68 Quad 1- 70w S62 Quad 1- 70w S62 480 1- 100w S54 Quad 1- 100w S54 480 1- 150w S55 Quad 1- 150w S55 480 1- 250w S50 Multi-5 for all voltages 1- 250w S50 Multi-5 with Lamp (555K) 1- 250w S50 Quad 1- 400w S51 Quad smaller standard frame 1- 400w S51 Quad 1- 400w S51 Multi-5 for all voltages 1- 400w S51 Multi-5 with lamp (555K) 1- 400w S51 Multi-5 in smaller standard frame 1- 400w S51 480 in smaller frame 1- 400w S51 480 1- 1000w S52 Quad 1- 1000w S52 480 1- 1000w S52 Multi-5 for all voltages DISTRIBUTOR REPLACEMENT BALLAST KITS - MERCURY 86519 86527 86542 H100MLTAC3M500K H175MLTAC3M500K H400MLTAC4M500K METAL HALIDE 86576 86578 86574 86563 86564 42670 80728 11210277CTC000C 11210506CTC000C 11210239CTC000I 1110245SCTC000I 1110246CTC000C 1110-247SC-TC 1111-247SCTC000I HIGH PRESSURE SODIUM 86605 86596 86606 1233142U000I 12210237CTC000I 1233154U000I *Quad = 120V, 208V, 240V, 277V Multi 5 = 120V, 208V, 240V, 277V, 480V See www.gelighting.com e-catalog for the most up-to-date product information. 4-43 Compact Fluorescent Lamps PLUG-IN LAMPS 2-Pin Low Wattage Biax® ................................................................................................. 5-7 4-Pin High Lumen Biax® .................................................................................................... 5-7 2-Pin Double Biax® ............................................................................................................... 5-8 4-Pin Double Biax® ............................................................................................................... 5-8 4-Pin Triple Biax® .................................................................................................................. 5-8 4-Pin High Output Biax® .................................................................................................... 5-9 4-Pin 2D® .................................................................................................................................. 5-9 SELF-BALLASTED LAMPS Spiral® ......................................................................................................................................5-10 Biax® .........................................................................................................................................5-11 Reflectors ................................................................................................................................5-11 Genura® ..................................................................................................................................5-12 Decorative Shapes .............................................................................................................5-12 LAMPS AND ADAPTERS Circlite® ....................................................................................................................................5-13 2D®-Electronic .....................................................................................................................5-13 BRIGHT STIK® LIGHTING UNITS ..........................................5-13 CROSS REFERENCE ...............................................................5-16 GE ENHANCED PLUG-IN PRODUCT CONVERSION ..........5-18 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering ✹ TLCP Compliant Plug-Ins B ▲ EOL Protection Plug-Ins ★ Energy Star Screw-Ins 5-1 Compact Fluorescent Lamps NOMINAL LENGTH BULB IDENTIFICATION NOMINAL LENGTH: Overall length including base or pins. Note: Lamp drawings are not drawn to scale. Be sure to check size and dimension information when identifying each lamp. To convert inches to millimeters, multiply the dimension (in inches) by 25.4 (i.e. 1.5'’ x 25.4 = 38.1 mm). LAMP LOCATOR F5BX G23 F7BX G23 F9BX G23 F13BX GX23 2-Pin Low Wattage Biax® F13DBX F18DBX F26DBX G24q-1 G24q-2 G24q-3 4-Pin Double Biax® F9DBX G23-2 F13DBX GX23-2 F18DBX F26DBX G24d-2 G24d-3 2-Pin Double Biax® F13TBX G24q-1 F18TBX G24q-2 F26TBX G24q-3 4-Pin Triple Biax® 4-Pin 2D® GR10Q-4 4-Pin 2D® F32TBX G24q-3 F42TBX G24q-4 F57QBX G24q-5 F70QBX G24q-6 F18BX 2G11 F27BX 2G11 4-Pin High Output Biax® F39BX 2G11 F40BX 2G11 4-Pin High Lumen Biax® Plug-in Lamps 5-2 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering ✹ TLCP Compliant Plug-Ins B ▲ F50BX 2G11 EOL Protection Plug-Ins ★ Energy Star Screw-Ins F55BX 2G11 Compact Fluorescent Lamps FLE10HT3 Med FLE15HT3 Med FLE13HT3 Med FLE20HT3 Med FLE26HT3 Med FLE42HLX Med Spiral® FLE12TT3 Med Candle Candle E12 Med FLE11/ A-Line Med FLE24QBX Med FLE28QBX FLE29QBX Med Med Biax® Genura® Spiral® FLE11/R30 Med FLE20TT3 Med EL23 Med FLE10HT2 FLE13HT2 FLE15HT2 Med Med Med FLE11/R20 Med FLE14TT3 FLE15TT3 Med Med FLE15/A2/ R30 Med FLE12/ A-Line Med FLE15/R30 FLE23/A4/R40 Dimming Med Med Reflectors FLE15/R30 Med FLE14/ A-Line Med FLE15/ A-Line Med FLE20/ A-Line Med FLE26/R40 Med FLE9/ FLE15TBX/ Globe Globe Med Med Decorative Shapes FLE26/R40 Dimming Med FLE15/A3/ Globe Med FLE26/PAR38 Med FLE11/ FLE15/ Post Light Post Light Med Med FLE15TBX/ Bullet Med FLE20TBX/ Bullet Med Self-Ballasted Lamps FEA 2D Med 2D®-Electronic FCA21 Med FEA30 Med FBS25 Circlite® Bright Stik® Lamps and Adapters For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering ✹ TLCP Compliant Plug-Ins B ▲ EOL Protection Plug-Ins ★ Energy Star Screw-Ins 5-3 Compact Fluorescent Lamps BASE IDENTIFICATION G23-2 (DBX2P) GX23-2 (DBX2P) G24d-1 (DBX2P) G24q-1 (DBX4P) G24q-2 (DBX4P) G24q-3 (DBX4P) G24d-2 (DBX2P) G23 (LWBX) G24d-3 (DBX2P) GX23 (LWBX) GRY10q-3 (2D4P) GR10q-4 (2D4P) 2G11-4 (HLBX) GX24q-1 (TBX4P) GX24q-2 (TBX4P) GX24q-3 (TBX4P) GX24q-4 (TBX4P) GX24q-5 (QBX4P) E26 Med Screw GX24q-6 (QBX4P) E12 Candelabra INTRODUCTION GE Compact Fluorescent Lamps offer many advantages: • Dramatic energy cost savings… up to 77% vs. incandescent lamps of comparable light output • Extra long life… most last 8 to 10 times longer, and some last up to 20 times longer, than standard incandescent lamps • High light output comparable, and in some cases exceeding, incandescent lamps replaced • Excellent color rendering… rare earth tri-phosphor provides such high quality color you won’t believe it’s fluorescent. Most types offer a choice of color options, from warm to cool, to let you select the tone and atmosphere you need. • A choice of wattages, shapes and sizes to meet your lighting needs. Designed to fit everything from table lamps to wall sconces and ceiling fixtures. • Many lamps use amalgam technology which provides stable lumen performance when operated in any position, over a wider range of ambient temperatures. 5-4 COMPACT FLUORESCENT BRAND NAME CROSS-REFERENCE GE Dulux® S Dulux® L Dulux® D, D/E Dulux® T/E Dulux® EL Twist Dura-One PHILIPS PL-S PL-L PL-C PL-T PL-H EL Twist - ATTENTION: This brand-name cross-reference chart is provided only as a quick reference. Other lamp company brand listings may only represent a near equivalent, versus an identical match to GE Lighting brands. Individual lamp manufacturer’s performance specifications should be consulted. Lamp performance may be affected by environmental conditions, ballast type and/or other auxiliary equipment. For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering ✹ TLCP Compliant Plug-Ins B OSRAM/SYLVANIA 2D® Biax® High Lumen Biax® Double Biax® Triple Biax® Quad Biax® High Output Biax® Spiral® Genura® ▲ EOL Protection Plug-Ins ★ Energy Star Screw-Ins Compact Fluorescent Lamps PRODUCT INFORMATION PLUG-IN LAMPS SELF-BALLASTED LAMPS 2-Pin Low Wattage Biax® (pg 5-7) Spiral® (pgs 5-10 to 5-11) • Compact size offers fixture and design flexibility • GX23 and G23 bases are preheat lamps with internal starters • 13 watt version also available with internal electronic starter, providing flicker-free instant on • Available in warm and cool color temperatures • TCLP Compliant • • • • • 4-Pin High Lumen Biax® (pgs 5-7 to 5-8) Biax® (pg 5-11) • Available in a range of sizes and wattages for innovative compact luminaires • High efficiency and outstanding performance in fixtures make them ideal for 2X2, 1X1 and indirect fixtures • Available in warm to cool color temperatures; excellent color rendering • • • • • 2-Pin Double Biax® (pg 5-8) • More compact than low wattage Biax® CFLs with higher lumen output - suitable for a broad range of applications • Preheat lamps with starters; not suitable for use with dimming ballasts • 26 watt version also available with internal electronic starter, providing flicker-free instant on • Available in warm to cool color temperatures • TCLP Compliant 4-Pin Double Biax® (pg 5-8) • More compact than low wattage Biax® CFLs with higher lumen output - suitable for a broad range of applications • Dimmable and compatible with electronic ballasts • Available in warm to cool color temperatures • TCLP Compliant 4-Pin Triple Biax® (pgs 5-8 to 5-9) • GE’s shortest, most compact Biax® lamp. 17-31% shorter than similar wattage Double Biax® lamps. • 4-Pin, dimmable and compatible with electronic ballasts • Available in a wide range of wattages: from 13 to 42 watts • Available in warm to cool color temperatures • TCLP Compliant Super long life – from 10,000 to 15,000 hour rating One piece unit screws directly into incandescent sockets Wide variety of wattages to meet application needs T3 Mini Biax® CFL provides longest life with smallest overall size Selected lamps offer 3-way or dimming functionality Reflectors (pgs 5-11 to 5-12) • R20, R30 and R40 glass reflectors available to meet application needs • Medium based; fits most incandescent reflector applications • R30 and R40 lamps available with dimming functionality Genura® (pg 5-12) • Extremely long life – rated life of 15,000 hours • One piece unit screws directly into incandescent sockets • Provides more light than 75W incandescent reflector lamps • Electrodeless design Decorative Shapes (pgs 5-12 to 5-13) • Variety of shapes (A-Line, Bullet, Candle, Globe, and Post) and wattages to meet all needs • One piece unit screws directly into incandescent sockets • Candle-shaped CFLs available in both medium base and candelabra base LAMPS AND ADAPTERS Circlite® (pg 5-13) • Lamp and adapter are separate. Replaceable lamps plug into adapters that screw into standard incandescent sockets. • Lamps last 10,000 hours; adapters last 40,000 hours (4 lamp lives) 2D®-Electronic (pg 5-13) 4-Pin High Output Biax® (pg 5-9) • • • • • Long life – up to 12,000 hours One piece unit screws directly into incandescent sockets Wide variety of wattages to meet application needs T2 & T3 Spiral® CFLs provide economical solution with small overall size The 42-watt T4 Spiral® CFLprovides a 150W incandescent replacement in the smallest possible size (fits an 8.5" harp) • Lamp and adapter are separate. Replaceable lamps plug into adapters that screw into standard incandescent sockets. • Lamps last 10,000 hours; adapters last 40,000 hours (4 lamp lives) GE’s highest light output compact fluorescent lamps High efficacy 72-75 LPW Dimmable, available in 5 colors (2,700 to 5,000K) Suitable for high-bay lighting TCLP Compliant 4-Pin 2D® (pgs 5-9) • Unique shape suitable for broad range of applications • Uniform light distribution • High light output – up to 200W incandescent equivalent For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering ✹ TLCP Compliant Plug-Ins B ▲ EOL Protection Plug-Ins ★ Energy Star Screw-Ins 5-5 Compact Fluorescent Lamps HEADINGS IN THIS CATALOG SECTION The following terms and descriptions can help you when checking Compact Fluorescent lamp specifications and when ordering products. Within each product line, lamps are divided into families, within these families, lamps are then listed by wattage. Light Output - Mean Lumens: Lamp light output (lumens) at 40% of rated Color Temperature - Kelvins (K): lamp life. A measure of the visual “warmth” or “coolness” of the light from the lamp. The higher the value, the whiter or “cooler” the light appears. Light Output - Initial Lumens: Light output (as defined by FTC Lamp Label Rules) is rated average lumens. Energy Used Nominal Watts: Color Rendering Index (CRI or Ra): An indication of the ability of the lamp to render object colors in a normal, natural way. The higher the number (0-100), the better the color appearance. Rated Life Energy Used (as defined by FTC lamp label rules). To estimate energy consumption (kWh), multiply watts x hours of use and divide by 1000. Minimum Starting Temperature: @ 12hrs. per start The minimum ambient temperature at which the lamp will start reliably. Rated Life - Hours: Power Factor (PF): Life (as defined by FTC Lamp Label Rules) is rated life in hours. Nominal Length: Lamp length including base and/or pins. A measure of power quality. The ratio of total watts to total volt-amperes. A value of 1.0 is ideal. Case Quantity: Total Harmonic Distortion (THD): Number of product units packed in a case. A measure (in percent) of power quality. Indicates the distortion of the alternating current wave form. Low values (<20%) are preferred. Order Code: It is important to use this five-digit code when ordering to ensure that you receive the exact product you require. Base: Description: The type of base. The lamp‘s identification code. Nominal Length Order Base Watts in. Code Description Additional Information: Typical application and/or other important information. Volt: Footnotes: Rated voltage. Related footnotes, see page 5-14. Warning Notices: Related warnings, see pages 5-14 to 5-15. Rated Color Min. Start Case Life Lumens Temp. Temp. Power Qty Volt Hours Initial Mean K. CRI (°F) Factor THD Warning Notices Footnotes Additional Information SELF-BALLASTED LAMPS SPIRAL® Med 42 6.4 16107 FLE42HLX/VT/827 10 120 10000 2650 2275 2700 82 14 0.6 170 ✐ B BASE DOWN OPERATION ONLY, T4 Spiral®, RE 827 Phosphor, Boxed 154 1, 7, 10, 15 FL E 42 HLX / VT / 827 Identifies as Fluorescent Lamp Electronically ballasted Identifies wattage Identifies additional information (Vented, Table Lamp) Identifies lamp shape Identifies lamp’s finish or color WHEN YOU DON’T KNOW THE LAMP DESCRIPTION 1. Identify bulb shape next to lamp information. 2. Measure bulb diameter using ruler in appendix section page A-1 to determine width in eighths of an inch. 3. Identify base type using table on page 5-4. 4. Find your lamp in the table containing the bulb shape, size and base. 5-6 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering ✹ TLCP Compliant Plug-Ins B ▲ EOL Protection Plug-Ins ★ Energy Star Screw-Ins Compact Fluorescent Lamps Nominal Length Order Base Watts in. Code Description Rated Rated Color Min. Start Case Life Life Lumens Temp. Temp. Qty. Volt Hours 12 Hrs. Initial Mean K. CRI (°F) Warning Notice Footnotes Additional Information PLUG-IN LAMPS 2-PIN LOW WATTAGE BIAX® ☞ G23 GX23 5 4.2 97551 F5BX/827/ECO 97552 F5BX/827/CDECO 97553 F5BX/841/ECO 7 5.3 97554 F7BX/827/ECO 97555 F7BX/827/CDECO 97556 F7BX/835/ECO 97557 F7BX/841/ECO 9 6.6 97558 F9BX/827/ECO 97559 F9BX/827/CDECO 97560 F9BX/835/ECO 97561 F9BX/841/ECO 13 7.0 97573 F13BX/827/ECO 97567 F13BX/827/CDECO 97574 F13BX/830/ECO 97569 F13BX/835/ECO 97568 F13BX/835 100P 97571 F13BX/841/ECO 97570 F13BX/841 100P 97572 F13BX/850/ECO 97562 F13BX/E/827/ECO 97563 F13BX/E/830/ECO 97564 F13BX/E/835/ECO 97565 F13BX/E/841/ECO 97566 F13BX/E/850/ECO 100 6 100 100 6 100 100 100 6 100 100 100 6 100 100 100 100 100 100 100 100 100 100 100 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 265 265 265 425 425 425 425 600 600 600 600 825 825 825 825 825 825 825 785 825 825 825 825 785 220 220 220 350 350 350 350 500 500 500 500 710 710 710 710 710 710 710 675 710 710 710 710 675 2700 2700 4100 2700 2700 3500 4100 2700 2700 3500 4100 2700 2700 3000 3500 3500 4100 4100 5000 2700 3000 3500 4100 5000 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 80 82 82 82 82 80 40 40 40 40 40 40 40 40 40 40 40 40 40 40 36 40 36 40 36 36 40 40 40 25 25 25 10000 10000 10000 20000 20000 20000 20000 12000 12000 12000 12000 12000 12000 20000 20000 20000 20000 20000 20000 20000 14000 14000 14000 10000 10000 10000 1200 1200 1200 1250 1250 1250 1160 1800 1800 1800 2850 2850 2850 3150 3150 3150 3150 3150 3150 2900 4000 4000 4000 4800 4800 4800 1080 1080 1080 1130 1130 1130 1050 1620 1620 1620 2510 2510 2510 2840 2840 2840 2840 2840 2840 2700 3400 3400 3400 4080 4080 4080 3000 3500 4100 3000 3500 4100 6500 3000 3500 4100 3000 3500 4100 3000 3000 3500 3500 4100 4100 5000 3000 3500 4100 3000 3500 4100 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 80 82 82 82 82 82 82 B✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐B ✹ ✐ B ✹ ✐ 4-PIN HIGH LUMEN BIAX® 2G11 18 9.0 16649 F18BX/SPX30 10PK 16053 F18BX/SPX35 10PK 16940 F18BX/SPX41 10PK 10.5 17174 F18BX/SPX30/RS 17175 F18BX/SPX35/RS 17176 F18BX/SPX41/RS 12521 F18BX/SPX65/RS 27 12.8 16944 F27BX/SPX30/RS 16948 F27BX/SPX35/RS 16951 F27BX/SPX41/RS 39 16.5 16538 F39BX/SPX30/RS 15867 F39BX/SPX35/RS 16952 F39BX/SPX41/RS 40 22.5 16953 F40/30BX/SPX30 20444 F40/30BX/SPX30-36 16648 F40/30BX/SPX35 20446 F40/30BX/SPX35-36 16954 F40/30BX/SPX41 20447 F40/30BX/SPX41-36 10490 F40/30BX/SPX50RS 50 22.5 20898 F50BX/SPX30/RS 20899 F50BX/SPX35/RS 20900 F50BX/SPX41/RS 55 20.7 31951 F55BX/830 31952 F55BX/835 31953 F55BX/840 -4 -4 -4 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 B B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B Carded Carded Carded Carded Bulk Pack Bulk Pack Internal Electronic Starter Internal Electronic Starter Internal Electronic Starter Internal Electronic Starter Internal Electronic Starter ✐ ✐ Bulk Pack Bulk Pack Bulk Pack Bulk Pack For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering ✹ TLCP Compliant Plug-Ins B ▲ EOL Protection Plug-Ins ★ 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 1,2,4,6 1,2,4,6 1,2,4,6 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 1,2,6,13 Energy Star Screw-Ins 5-7 Compact Fluorescent Lamps Nominal Length Order Base Watts in. Code Description Rated Rated Color Min. Start Case Life Life Lumens Temp. Temp. Qty. Volt Hours 12 Hrs. Initial Mean K. CRI (°F) Additional Information Warning Notice Footnotes PLUG-IN LAMPS (CONTINUED) 4-PIN HIGH LUMEN BIAX® (CONTINUED) 2G11 55 20.7 45851 F55BX/AR/FS 6PK 6 45859 F55BX/AR/FS/BULK 25 10000 10000 4800 4080 4800 4080 9325 9325 67 67 10 10 50 50 50 6 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 550 550 810 810 810 810 810 900 900 900 900 1200 1200 1200 1200 1710 1710 1710 1710 1710 1710 1710 1710 470 470 685 685 685 685 685 755 755 755 755 980 980 980 980 1460 1460 1460 1460 1460 1460 1460 1460 2700 4100 2700 2700 3000 3500 4100 2700 3000 3500 4100 2700 3000 3500 4100 2700 3000 3500 4100 2700 3000 3500 4100 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐ B ✹ 50 50 50 50 50 50 50 50 50 50 50 50 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 900 900 900 900 1200 1200 1200 1200 1710 1710 1710 1710 755 755 755 755 970 970 970 970 1440 1440 1440 1440 2700 3000 3500 4100 2700 3000 3500 4100 2700 3000 3500 4100 82 82 82 82 82 82 82 82 82 82 82 82 B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐ B ✹ ▲ 10 10 10 10 10 10 10 10 10 12000 12000 12000 12000 12000 12000 12000 12000 12000 20000 20000 20000 20000 20000 20000 20000 20000 20000 900 900 900 900 900 1200 1200 1200 1200 755 755 755 755 755 1010 1010 1010 1010 2700 2700 3000 3500 4100 2700 2700 3000 3500 82 82 82 82 82 82 82 82 82 ✐ B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✹ ▲ ✐ ✐ 2-PIN DOUBLE BIAX® ☞ G23-2 GX23-2 G24d-1 G24d-2 G24d-3 9 4.3 97576 F9DBX23/827/ECO 97575 F9DBX23/841/ECO 13 4.7 97586 F13DBX23/827/ECO 97585 F13DBX/827/CD 97587 F13DBX23/830/ECO 97588 F13DBX23/835/ECO 97589 F13DBX23/841/ECO 13 5.3 97590 F13DBX/827/ECO 97591 F13DBX/830/ECO 97592 F13DBX/835/ECO 97593 F13DBX/841/ECO 18 6.1 97577 F18DBX/827/ECO 97578 F18DBX/830/ECO 97579 F18DBX/835/ECO 97580 F18DBX/841/ECO 26 6.7 97606 F26DBX/827/ECO 97607 F26DBX/830/ECO 97608 F26DBX/835/ECO 97609 F26DBX/841/ECO 97602 F26DBX/E/827/ECO 97603 F26DBX/E/830/ECO 97604 F26DBX/E/835/ECO 97605 F26DBX/E/841/ECO 4-PIN DOUBLE BIAX® ☞ G24q-1 13 5.0 97594 F13DBX/827/ECO4P 97595 F13DBX/830/ECO4P 97596 F13DBX/835/ECO4P 97597 F13DBX/841/ECO4P G24q-2 18 5.8 97598 F18DBX/827/ECO4P 97599 F18DBX/830/ECO4P 97600 F18DBX/835/ECO4P 97601 F18DBX/841/ECO4P G24q-3 26 6.4 97610 F26DBX/827/ECO4P 97611 F26DBX/830/ECO4P 97612 F26DBX/835/ECO4P 97613 F26DBX/841/ECO4P 4-PIN TRIPLE BIAX® ☞ GX24q-1 13 4.2 97623 F13TBX827/4P/ECO 97619 F13TBX/827/A/ECO 97620 F13TBX/830/A/ECO 97621 F13TBX/835/A/ECO 97622 F13TBX/841/A/ECO GX24q-2 18 4.8 97628 F18TBX827/4P/ECO 97624 F18TBX/827/A/ECO 4.8 97625 F18TBX/830/A/ECO 4.8 97626 F18TBX/835/A/ECO Fresh and Salt Water Phosphor Fresh and Salt Water Phosphor B B ✐ ✐ ✹ ✹ ✹ Carded ✹ ✹ ✹ ✹ ✹ ✹ ✹ ✹ ✹ ✹ ✹ ✹ ✹ ✹ ✹ ✹ ✹ ✹ ✹ Internal Electronic Starter Internal Electronic Starter Internal Electronic Starter Internal Electronic Starter ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ Non-Amalgam ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ Non-Amalgam ✹ ▲ ✹ ▲ ✹ ▲ ☞ New Product Codes. (These product codes will be available September 2006. Until that time, use order code found on page 5-18). 5-8 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering ✹ TLCP Compliant Plug-Ins B ▲ EOL Protection Plug-Ins ★ Energy Star Screw-Ins 151 151 1,2,6,13 1,2,6,13 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 151 1,2,17 1,2,17 1,2,17 1,2,17 1,2,17 1,2,17 1,2,17 1,2,17 1,2,17 1,2,17 1,2,17 1,2,5,17 1,2,5,17 1,2,5,17 1,2,5,17 1,2,17 1,2,17 1,2,17 1,2,17 1,2,15,17 1,2,15,17 1,2,15,17 1,2,15,17 151 151 151 151 151 151 151 151 151 151 151 151 1,2,6,17 1,2,6,17 1,2,6,17 1,2,6,17 1,2,5,6,17 1,2,5,6,17 1,2,5,6,17 1,2,5,6,17 1,2,6,17 1,2,6,17 1,2,6,17 1,2,6,17 151 1,2,6,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 Compact Fluorescent Lamps Nominal Length Order Base Watts in. Code Description Rated Rated Color Min. Start Case Life Life Lumens Temp. Temp. Qty. Volt Hours 12 Hrs. Initial Mean K. CRI (°F) Warning Notice Footnotes Additional Information PLUG-IN LAMPS (CONTINUED) 4-PIN TRIPLE BIAX® (CONTINUED) ☞ GX24q-2 18 4.8 97627 F18TBX/841/A/ECO GX24q-3 26 5.2 97618 F26TBX827/4P/ECO 97614 F26TBX/827/A/ECO 97615 F26TBX/830/A/ECO 97616 F26TBX/835/A/ECO 97617 F26TBX/841/A/ECO GX24-q3 32 5.5 97629 F32TBX/827/A/ECO 97630 F32TBX/830/A/ECO 97631 F32TBX/835/A/ECO 97632 F32TBX/841/A/ECO GX24-q4 42 6.4 97633 F42TBX/827/A/ECO 97634 F42TBX/830/A/ECO 97635 F42TBX/835/A/ECO 97636 F42TBX/841/A/ECO 10 10 10 10 10 10 10 10 10 10 10 10 10 10 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 1200 1710 1710 1710 1710 1710 2200 2200 2200 2200 3200 3200 3200 3200 1020 1440 1440 1440 1440 1440 1850 1850 1850 1850 2690 2690 2690 2690 4100 2700 2700 3000 3500 4100 2700 3000 3500 4100 2700 3000 3500 4100 82 82 82 82 82 82 82 82 82 82 82 82 82 82 10 10 10 10 10 10 10 10 10 10 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 4300 4300 4300 4300 4300 5200 5200 5200 5200 5200 3700 3700 3700 3700 3700 4470 4470 4470 4470 4470 2700 3000 3500 4100 5000 2700 3000 3500 4100 5000 60 50 50 50 50 20 20 20 5 20 48 20 5 48 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 650 1050 1050 1350 1350 2050 2050 2850 2850 2850 3900 4000 4000 3900 545 880 880 1135 1135 1720 1720 2395 2395 2395 3300 3400 3400 3300 2700 2700 3500 2700 3500 2700 3500 2700 2700 3500 2700 3000 3000 3500 ✐ B B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐ B ✹ ▲ ✐ ✹ ▲ 82 82 82 82 82 82 82 82 82 82 ✐ B B ✐B ✐B ✐B ✹ ✐B ✐B ✐B ✐B ✐ B ✹ ▲ ✐ ✹ ▲ 82 82 82 82 82 82 82 82 82 82 82 82 82 82 B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B ✐B 4-PIN HIGH OUTPUT BIAX® ☞ GX24q-5 57 7.1 48861 F57QBX/827/A/ECO 48862 F57QBX/830/A/ECO 48863 F57QBX/835/A/ECO 48864 F57QBX/841/A/ECO 93404 F57QBX/850/A/ECO GX24q-6 70 8.2 48865 F70QBX/827/A/ECO 48866 F70QBX/830/A/ECO 48867 F70QBX/835/A/ECO 48868 F70QBX/841/A/ECO 93406 F70QBX/850/A/ECO 4-PIN 2D® GR10q-4 10 3.6 21301 F102D/827/4P 16 5.5 22169 F162D/827/4P 22177 F162D/835/4P 21 5.5 21303 F212D/827/4P 22178 F212D/835/4P 28 8.1 22172 F282D/827/4P 22180 F282D/835/4P 38 8.1 21305 F382D/827/4P 25427 F38/2D/827/4P/CD 22181 F382D/835/4P GRY10q-3 55 8.1 37525 F552D/827/A/4P/B 36358 F552D/830A/T4P/B 40184 F552D/830/4P/CD 37529 F552D/835/A/4P/B 151 1,2,6,12,17 151 1,2,6,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 Non-Amalgam ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 151 1,2,6,12,17 ✹ ▲ ✹ ▲ ▲ ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ ✹ ▲ ✐ 151 151 151 151 151 151 151 151 Carded 151 151 Bulk Pack 151 Torchiere Replacement Lamp 151 Torchiere Replacement Lamp, Carded 151 Bulk Pack 151 1,2,3,6 1,2,3,6 1,2,3,6 1,2,3,6 1,2,3,6 1,2,3,6 1,2,3,6 1,2,3,6 1,2,3,6 1,2,3,6 1,2,3,6 1,2,3,6 1,2,3,6 1,2,3,6 ☞ New Product Codes. (These product codes will be available September 2006. Until that time, use order code found on page 5-18). For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering ✹ TLCP Compliant Plug-Ins B ▲ EOL Protection Plug-Ins ★ Energy Star Screw-Ins 5-9 Compact Fluorescent Lamps Nominal Length Order Base Watts in. Code Description Rated Color Min. Start Case Life Lumens Temp. Temp. Power Qty Volt Hours Initial Mean K. CRI (°F) Factor THD Warning Notices Footnotes Additional Information SELF-BALLASTED LAMPS SPIRAL® 120 8000 520 420 2700 82 120 8000 520 420 2700 82 120 8000 520 420 2700 82 5 0.6 120 5 0.6 120 5 0.6 120 ✐ B★ ✐B ★ ✐ B★ T3 Spiral®, Boxed T3 Spiral®, Carded Single Pack T3 Spiral®, Carded Twin Pack 153 153 153 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 120 8000 120 8000 120 12000 120 12000 120 12000 120 12000 120 12000 120 12000 120 8000 120 8000 520 500 550 550 550 580 580 580 825 825 420 400 440 440 440 464 464 464 660 660 4100 6500 2700 2700 2700 2700 2700 2700 2700 2700 82 82 82 82 82 82 82 82 82 82 5 5 5 5 5 5 5 5 5 5 0.6 120 0.6 120 0.6 120 0.6 120 0.6 120 0.6 120 0.6 120 0.6 120 0.6 120 0.6 120 ✐ B★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐ B★ T3 Spiral®, Boxed T3 Spiral®, Carded Twin Pack T3 Spiral®, Boxed T3 Spiral®, Carded Single Pack T3 Spiral®, Carded Twin Pack T2 Spiral®, Boxed T2 Spiral®, Carded Single Pack T2 Spiral®, Carded Twin Pack T3 Spiral®, Carded Single Pack T3 Spiral®, Carded Twin Pack 153 153 153 153 153 153 153 153 153 153 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 120 120 120 120 120 120 120 120 120 8000 8000 8000 8000 8000 8000 8000 8000 6000 825 870 870 870 950 950 950 950 850 660 715 715 715 765 765 765 765 685 2700 2700 2700 2700 2700 2700 2700 2700 2700 82 82 82 82 82 82 82 82 82 5 5 5 5 5 5 5 5 5 0.6 120 0.6 120 0.6 120 0.6 120 0.6 145 0.6 145 0.6 145 0.6 145 0.6 145 B★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐ B★ 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 25183 FLE15HT3/2/841 10 85394 FLE15HT3/2/D/2PK 3 80937 FLE15HT3/2/XL 10 47435 FLE15HT3/2/XL/CD 12 49680 FLE15HT3/2/XL2PK 3 15 86271 FLE15HT2/2/827 10 85385 FLE15HT2/2/SW/CD 12 85391 FLE15HT2/2/SW2PK 3 20 4.7 15834 FLE20HT3/2/827 10 15516 FLE20HT3/2/SW/CD 12 15518 FLE20HT3/2/SW/2PK 3 16253 FLE20HT3/2/6H/4PK 3 120 8000 120 8000 120 12000 120 12000 120 12000 120 12000 120 12000 120 12000 120 8000 120 8000 120 8000 120 6000 950 900 950 950 950 950 950 950 1200 1200 1200 1150 765 738 760 760 760 780 780 780 965 965 965 925 4100 6500 2700 2700 2700 2700 2700 2700 2700 2700 2700 2700 82 82 82 82 82 82 82 82 82 82 82 82 5 5 5 5 5 5 5 5 5 5 5 5 0.6 145 0.6 145 0.6 145 0.6 145 0.6 145 0.6 145 0.6 145 0.6 145 0.6 135 0.6 135 0.6 135 0.6 135 B★ B★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐ B★ 25186 FLE20HT3/2/841 10 85396 FLE20HT3/2/D/2PK 3 80888 FLE20HT3/2/XL 10 47442 FLE20HT3/2/XL/CD 12 49684 FLE20HT3/2/XL2PK 3 47466 FLE20HT3/2/XL/D 12 23 5.1 80889 FLE23HT3/2/XL 10 47445 FLE23HT3/2/XL/CD 12 15836 FLE26HT3/2/827 10 15517 FLE26HT3/2/SW/CD 12 15519 FLE26HT3/2/SW/2PK 3 120 8000 120 8000 120 12000 120 12000 120 12000 120 12000 120 12000 120 12000 120 8000 120 8000 120 8000 1200 1150 1300 1300 1300 1300 1600 1600 1750 1750 1750 965 945 1040 1040 1040 1040 1280 1280 1400 1400 1400 4100 6500 2700 2700 2700 6500 2700 2700 2700 2700 2700 82 82 82 82 82 82 82 82 82 82 82 5 5 5 5 5 5 5 5 5 5 5 0.6 135 0.6 135 0.6 135 0.6 135 0.6 135 0.6 135 0.6 0.6 0.6 120 0.6 120 0.6 120 ✐ T3 Spiral®, Consumer 10 Pack 153 T2 Spiral®, Boxed 153 T2 Spiral®, Carded Single Pack 153 T2 Spiral®, Carded Twin Pack 153 T3 Spiral®, Boxed 153 T3 Spiral®, Carded Single Pack 153 T3 Spiral®, Carded Twin Pack 153 T3 Spiral®, Carded 3 Pack 153 6000 Hr Life, T3 Spiral®, 153 Boxed Consumer 4 Pack T3 Spiral®, Boxed 153 T3 Spiral®, Carded Twin Pack 153 T3 Spiral®, Boxed 153 T3 Spiral®, Carded Single Pack 153 T3 Spiral®, Carded Twin Pack 153 T2 Spiral®, Boxed 153 T2 Spiral®, Carded Single Pack 153 T2 Spiral®, Carded Twin Pack 153 T3 Spiral®, Boxed 153 T3 Spiral®, Carded Single Pack 153 T3 Spiral®, Carded Twin Pack 153 6000 Hr Life, T3 Spiral®, 153 Boxed Consumer 4 Pack T3 Spiral®, Boxed 153 T3 Spiral®, Carded Twin Pack 153 T3 Spiral®, Boxed 153 T3 Spiral®, Carded Single Pack 153 T3 Spiral®, Carded Twin Pack 153 T3 Spiral®, Carded Single Pack, Daylight 153 T3 Spiral®, Boxed 153 T3 Spiral®, Carded Single Pack 153 T3 Spiral®, Boxed 153 T3 Spiral®, Carded Single Pack 153 T3 Spiral®, Carded Twin Pack 153 Med 10 4.4 15829 FLE10HT3/2/827 10 49906 FLE10HLX/2/SW/CD 12 49907 FLE10HLX/2/SW/ 3 CD/2PK 25182 FLE10HT3/2/841 10 85393 FLE10HT3/2/D/2PK 3 80936 FLE10HT3/2/XL 10 47430 FLE10HT3/2/XL/CD 12 49671 FLE10HT3/2/XL2PK 3 10 86241 FLE10HT2/2/827 10 85382 FLE10HT2/2/SW/CD 12 85389 FLE10HT2/2/SW2PK 3 13 4.7 16460 FLE13HT3/2/SW/CD 12 16459 FLE13HT3/2/SW/ 3 CD/2PK 21760 FLE13HT3/2/10PK 10 13 86256 FLE13HT2/2/827 10 85383 FLE13HT2/2/SW/CD 12 85390 FLE13HT2/2/SW2PK 3 15 4.8 15831 FLE15HT3/2/827 10 41520 FLE15HT3/2/SW/CD 12 41525 FLE15HT3/2/SW/2PK 3 00261 FLE15HT3/2/SW/3PK 3 16252 FLE15HT3/2/6H/4PK 3 5-10 ✐ ✐ ✐ B★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering ✹ TLCP Compliant Plug-Ins B ▲ EOL Protection Plug-Ins ★ Energy Star Screw-Ins 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,103 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 Compact Fluorescent Lamps Nominal Length Order Base Watts in. Code Description Rated Color Min. Start Case Life Lumens Temp. Temp. Power Qty Volt Hours Initial Mean K. CRI (°F) Factor THD Warning Notices Footnotes Additional Information SELF-BALLASTED LAMPS (CONTINUED) SPIRAL® (CONTINUED) Med 26 5.2 00262 FLE26HT3/2/SW/3PK 3 120 8000 1750 1400 2700 82 16254 FLE26HT3/2/6H/4PK 3 120 6000 1750 1400 2700 82 21845 FLE26HT3/2/10PK 25195 FLE26HT3/2/841 85397 FLE26HT3/2/D/2PK 80890 FLE26HT3/2/XL 47446 FLE26HT3/2/XL/CD 49685 FLE26HT3/2/XL2PK 29 6.3 81514 FLE29HLX/2/XL/827 47459 FLE29HLX/2/XL/CD 81515 FLE29HLX/2D3/827 10 10 3 10 12 3 10 12 10 120 8000 120 8000 120 8000 120 12000 120 12000 120 12000 120 12000 120 12000 120 10000 47448 FLE29HLX/2/D3/CD 12 120 10000 1700 1750 1600 1700 1700 1700 2200 2200 600 1600 2200 600 1600 2200 2700 2700 2650 1365 1400 1315 1360 1360 1360 1760 1760 480 1280 1760 480 1280 1760 2160 2160 2275 600 850 900 900 1200 1200 1200 1520 480 685 720 720 960 960 965 1290 2700 4100 6500 2700 2700 2700 2700 2700 2700 82 82 82 82 82 82 82 82 82 2700 82 5 0.6 120 5 0.6 120 B★ ✐ B★ 5 5 5 5 5 5 5 5 5 B★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐B ★ ✐ B★ 0.6 120 0.6 120 0.6 120 0.6 120 0.6 120 0.6 120 0.6 0.6 0.6 5 0.6 ✐ ✐ ✐ B★ T3 Spiral®, Carded 3 Pack 6000 Hr Life, T3 Spiral®, Boxed Consumer 4 Pack T3 Spiral®, Consumer 10 Pack T3 Spiral®, Boxed T3 Spiral®, Carded Twin Pack T3 Spiral®, Boxed T3 Spiral®, Carded Single Pack T3 Spiral®, Carded Twin Pack T4 Spiral®, Boxed T4 Spiral®, Carded Single Pack T4 Spiral®, Boxed, 3-way 153 153 1,7,8,9,10 1,7,8,9,10 153 153 153 153 153 153 153 153 155 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 1,7,8,9,10 T3 Spiral®, Carded Single Pack, 3-way 155 1,7,8,9,10 2700 82 2700 82 2700 82 5 0.6 170 5 0.6 170 14 0.6 170 ✐ B★ ✐ B★ ✐ B★ T4 Spiral®, Boxed T4 Spiral®, Carded Single Pack BASE DOWN OPERATION ONLY, T4 Spiral®, Boxed 153 153 154 1,7,8,9,10 1,7,8,9,10 1,7,10,15 2700 2700 2700 2700 2700 2700 2700 2700 5 5 5 5 5 5 5 -9 0.6 120 0.6 120 0.6 145 0.6 145 0.6 130 0.6 130 0.6 120 0.6 170 B★ ✐B ★ ✐B ✐B ✐B ★ ✐ B★ ✐B ★ ✐ B★ 1,7,8,9,10,12 1,7,8,9,10 1,7,8,9,10,12 1,7,8,9,10,12 1,7,8,9,10,12 1,7,8,9,10,12 1,7,8,9,10 1,7,8,9,10,12 27 6.9 49887 FLE27QBX/2/SW/CD 12 120 6000 1700 1365 2700 82 28 5.9 40351 FLE28QBX/LL/CD 3 120 12000 1750 1485 2700 82 5 0.6 130 -9 0.6 170 B★ ✐B 46270 FLE28QBX/A/827 6 120 12000 1750 1485 2700 82 29 6.3 41457 FLE29QBX/DV/827 6 120 10000 1750 1500 2700 82 45599 FLE29QBX/DV/827/CD 3 120 10000 1750 1500 2700 82 -9 0.6 170 -9 0.6 170 -9 0.6 170 B B ✐B T3 Triple Biax®, Boxed 153 Triple Biax®, Carded Single Pack 153 T3 Triple Biax®, Boxed 153 T3 Triple Biax®, Carded Single Pack 153 T3 Triple Biax®, Boxed 153 T3 Triple Biax®, Carded Single Pack 153 Triple Biax®, Carded Single Pack 153 New Quad Biax® design, 153 even shorter MOL, boxed Quad Biax®, Carded Single Pack 153 Soft White, Quad Biax®, Carded, 153 Standard Shell Ballast Shorter MOL 153 Dimming, Standard Shell Ballast 156 Dimming, Carded, Standard Shell Ballast 156 5 0.6 120 5 0.6 120 5 0.6 120 B ✐B ★ ✐ B★ 42 6.4 80891 FLE42HLX/2/XL 10 120 12000 47452 FLE42HLX/2/XL/CD 12 120 12000 16107 FLE42HLX/VT/827 10 120 10000 BIAX® Med 12 4.4 20702 FLE12TT3/827 14 5.9 49884 FLE14TBX/2/SW/CD 15 4.9 12004 FLE15TT3/827 12005 FLE15TT3/SW/CD 20 5.5 12008 FLE20TT3/827 12009 FLE20TT3/SW/CD 6.9 49885 FLE20TBX/2/SW/CD 24 5.6 23669 FLE24QBX/A/827 10 12 10 3 10 3 12 6 120 15000 120 8000 120 15000 120 15000 120 15000 120 15000 120 8000 120 12000 82 82 82 82 82 82 82 82 ✐ ✐ ✐ ✐ 1,7,8,9,10 1,7,8,9,10,12 1,7,8,9,10,12 1,7,8,9,12,14 1,7,8,9,12,14 REFLECTORS Med 11 4.7 20704 FLE11/R20 10 120 10000 370 296 2700 82 80892 FLE11/2/R20XL 10 120 10000 400 320 2700 82 47477 FLE11/2/R20XL/CD 12 120 10000 400 320 2700 82 15 5.5 49917 FLE15/A2/R30 6 120 10000 550 445 2700 82 -22 0.6 170 5.4 20708 FLE15/2/R30/SWCD 3 120 8000 720 580 2700 82 5 0.6 120 ✐ B ✐ B★ ✐ 5.5 80893 FLE15/2/R30XL 10 120 10000 750 600 2700 82 47478 FLE15/2/R30XL/CD 12 120 10000 750 600 2700 82 5 0.6 120 5 0.6 120 B★ ✐ B★ 5.6 21709 FLE15/2/DV/R30 5 0.6 110 ✐ 6 120 6000 720 580 2700 82 ✐ B★ Soft White, R20 Glass Reflector Soft White, R20 Glass Reflector, Boxed Soft White, R20 Glass Reflector, Carded Single Pack Soft White, R30 Glass Reflector Soft White, R30 Glass Reflector, Carded Single Pack Soft White, R30 Glass Reflector, Boxed Soft White, R30 Glass Reflector, Carded Single Pack Dimming, Soft White, R30 Glass Reflector, Boxed For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering ✹ TLCP Compliant Plug-Ins B ▲ EOL Protection Plug-Ins ★ 157 157 157 1,8,9,10,12 1,8,9,10,12 1,8,9,10,12 157 158 1,8,9,10,12 1,8,9,10,12 157 157 1,8,9,10,12 1,8,9,10,12 165 1,8,9,12,14 Energy Star Screw-Ins 5-11 Compact Fluorescent Lamps Nominal Length Order Base Watts in. Code Description Rated Color Min. Start Case Life Lumens Temp. Temp. Power Qty Volt Hours Initial Mean K. CRI (°F) Factor THD Warning Notices Footnotes Additional Information SELF-BALLASTED LAMPS (CONTINUED) REFLECTORS (CONTINUED) Med 15 5.6 21710 FLE15/2/DV/R30/SW/CD 3 120 6000 720 580 2700 82 5 0.6 110 ✐ B★ Med 23 5.9 15382 FLE23/A4/R40 6 120 10000 950 760 2700 82 -13 0.6 170 26 6.5 21738 FLE26/2/R40/SW/CD 3 120 6000 1300 1040 2700 82 5 0.6 120 ✐ ✐ B★ B★ 80894 FLE26/2/R40XL 47479 FLE26/2/R40XL/CD 6 120 10000 1300 1040 2700 82 3 120 10000 1300 1040 2700 82 5 0.6 120 5 0.6 120 ✐ B★ B★ 6 120 6000 1300 1040 2700 82 5 0.6 110 ✐ B★ 21718 FLE26/2/DV/R40/SW/CD 3 120 6000 1300 1040 2700 82 5 0.6 110 ✐ B★ 5.5 21739 FLE26/2/PAR38/SW/CD 3 120 6000 1200 970 2700 82 5 0.6 120 ✐ B★ 5.6 80895 FLE26/2/PAR38/XL 6 120 10000 1300 1040 2700 82 5 0.6 ✐ B★ 47483 FLE26/2/PAR38/XL 3 120 10000 1300 1040 2700 82 5 0.6 ✐ B★ 6.9 21716 FLE26/2/DV/R40 ✐ Dimming, Soft White, R30 Glass Reflector, Carded Single Pack Soft White, R40 Glass Reflector Soft White, R40 Glass Reflector, Carded Single Pack Soft White, R40 Glass Reflector, Boxed Soft White, R40 Glass Reflector, Carded Single Pack Dimming, Soft White, R40 Glass Reflector, Boxed Dimming, Soft White, R40 Glass Reflector, Carded Single Pack Soft White, Par 38 Glass Reflector, Carded Single Pack Soft White, Par 38 Glass Reflector, Boxed, Wet rated Soft White, Par 38 Glass Reflector, Carded Single Pack, Wet rated 165 1,8,9,12,14 157 158 1,8,9,10,12 1,8,9,10,12 157 157 1,8,9,10,12 1,8,9,10,12 165 1,8,9,12,14 165 1,8,9,12,14 1,8,9,12,16 166 1,8,9,12,16 166 1,8,9,12,16 ✐ B ✐B Genura® Electrodeless Design, Soft White 160 Genura® Electrodeless Design, 160 RE 830 Phosphor, Warm White 1,8,9,10 1,8,9,10 B ✐ B★ ✐B ✐ B★ ✐B Candle Shape, Candelabra Base, Boxed 157 Candle Shape, Medium Base, Boxed 157 Candle Shape, Candelabra Base, Boxed 157 Candle Shape, Medium Base, Boxed 157 Candle Shape, Candelabra Base, 157 Carded Single Pack Candle Shape, Candelabra Base, Boxed 157 Candle Shape, Medium Base, 157 Carded Single Pack Candle Shape, Medium Base, Boxed 157 A-Line Shape, Carded Single Pack 157 Globe Shape, Carded Single Pack 157 Post Light, Carded Single Pack 157 Bug Yellow Post Light, Carded Single Pack 157 A-Line Shape, Reduced Size, Boxed 157 Bug Yellow Post Light, Carded Single Pack 157 A-Line Shape, Carded Single Pack 157 Globe Shape, Carded Single Pack 157 A-Line Shape, Carded Single Pack 158 A-Line Shape, Reduced Size, Boxed 157 A-Line Shape, Reduced Size, 157 Carded Single Pack Bullet 158 Soft White, G30 Globe Slimshell Ballast 157 Soft White, G30 Globe, Reduced Overall Length 157 Post Light, Slimshell Ballast 157 1,8,10,12 1,8,10,12 1,8,10,12 1,8,10,12 1,8,10,12 GENURA® Med 23 4.9 25418 EL23/R25/SW 12273 EL23/R25/WW 6 120 15000 1100 880 2700 82 6 120 15000 1100 880 3000 82 32 0.6 130 32 0.6 130 DECORATIVE SHAPES Cand Med Cand Med Cand 5 5 7 7 9 Med 16105 FLE9/2/CAC/827 10 120 6000 430 344 2700 82 9 5.4 47488 FLE9/2/CAM/XL/CD 12 120 10000 430 344 2700 82 5-12 4.8 16098 FLE5/2/CAC/827 4.8 16099 FLE5/2/CAM/827 5.2 16103 FLE7/2/CAC/827 5.2 16104 FLE7/2/CAM/827 5.4 85388 FLE9/2/CAC/SW/CD 10 10 10 10 12 120 120 120 120 120 6000 6000 6000 6000 6000 200 200 370 370 430 160 160 296 296 344 2700 2700 2700 2700 2700 82 82 82 82 82 5 5 5 5 5 0.6 145 0.6 145 0.6 130 0.6 130 0.6 125 ✐ 5 0.6 125 5 0.6 125 ✐ B ✐ B★ 16106 FLE9/2/CAM/827 10 11 4.4 47486 FLE11/2/A17XL/CD 12 11 4.8 47484 FLE11/2/G25XL/CD 12 5.2 49894 FLE11/2/TC14/SW/CD 12 5.2 49895 FLE11/2/TC14/BUG/CD 12 12 4.8 20703 FLE12/A19/827 10 14 5 47464 FLE14/2/TC16/BUG 12 15 4.8 47487 FLE15/2/A21XL/CD 12 47485 FLE15/2/G25XL/CD 12 4.7 21733 FLE15/2/A21/SW/CD 12 5.4 12010 FLE15/A19/827 6 12011 FLE15/A19/SW/CD 3 120 6000 120 10000 120 10000 120 6000 120 6000 120 10000 120 10000 120 10000 120 10000 120 8000 120 10000 120 10000 430 550 550 520 520 550 750 825 800 850 825 825 344 440 440 420 420 440 600 660 640 689 660 660 2700 2700 2700 2700 2700 2700 2700 2700 2700 2700 2700 2700 82 82 82 82 82 82 82 82 82 82 82 82 5 5 5 5 5 5 5 5 5 5 5 5 0.6 125 0.6 0.6 0.6 120 0.6 120 0.6 120 0.6 0.6 0.6 0.6 120 0.6 145 0.6 145 B★ B★ ✐ B★ ✐ B★ ✐B ★ ✐B ✐B ★ ✐B ★ ✐ B★ ✐ B★ ✐B ✐B 15 5.3 41325 FLE15/6/T19/827 5.8 12501 FLE15TBX/L/G29 5.4 41546 FLE15/A3/G30 6 41464 FLE15/L/TC16/827 120 6000 120 12000 120 10000 120 12000 800 750 730 850 640 600 590 680 2700 2700 2700 2700 84 82 82 82 32 -9 -9 -9 0.6 170 0.6 170 0.6 170 0.6 170 ✐ 10 6 6 6 ✐ ✐ B ✐B ✐B ✐B For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering ✹ TLCP Compliant Plug-Ins B ▲ EOL Protection Plug-Ins ★ Energy Star Screw-Ins 1,8,10,12 1,8,10,12 1,8,10,12 1,8,10,12 1,8,10,12 1,8,10,12 1,8,10,12 1,8,10,12 1,8,10,12 1,8,10,12 1,8,10,12 1,8,10,12 1,8,10,12 1,8,10,12 1,8,10,12 1,8,10,12 1,8,10,12 1,8,10,12 Compact Fluorescent Lamps Nominal Length Order Base Watts in. Code Rated Color Min. Start Case Life Lumens Temp. Temp. Power Qty Volt Hours Initial Mean K. CRI (°F) Factor THD Description Warning Notices Footnotes Additional Information SELF-BALLASTED LAMPS (CONTINUED) DECORATIVE SHAPES (CONTINUED) Med 20 6.1 41456 FLE20/A2/A24/827 6 120 6000 1125 950 2700 82 41441 FLE20/A2/A24/SW/CD 3 120 6000 1125 950 2700 82 0 0.6 170 0 0.6 170 B B A-Line Shape, Slimshell Ballast 157 A-Line Shape, Carded, Slimshell Ballast 157 1,8,10,12 1,8,10,12 B ✐B Circlite, Carded, FC8T9/KB Replacement Lamp 163 Circlite, Carded Tray Pack, FC8T9/KB 163 Replacement Lamp Electronic Circlite, Carded, 164 Replacement Lamp FC8T9 1,7,10,11 1,7,10,11 ✐ ✐ LAMPS AND ADAPTERS CIRCLITE® Med 21 3.4 11307 FCA21/CD 48222 FCA21/D CD TRAY 4 120 10000 1200 1020 3000 82 4 120 10000 0.5 20 30 3.5 27251 FEA30CIR/SW/CD 4 120 10000 1900 1520 2700 82 32 0.6 170 ✐ B 32 0.5 ✐ B ✐ 1,7,10,11 2D®-ELECTRONIC Med 39 4.3 27253 FEA38/2D/3WAY/CD 4 120 10000 2780 2365 2700 82 2 3-Way, Carded Uses F382D/827 Replacement Lamp 164 1,3,7,10,11,12 BRIGHT STICK® LIGHTING UNITS 33 25 12257 FBS25/WX/PP 6 7500 725 3450 59 12263 FBS25/GS/PP 6 7500 470 3050 90 47912 FBS25/BLB/PP 6 7500 Bulb Base Nominal Length Order Watts in. Code Description Bright Stik, White Lamp-In-Holder Unit with Standard 2-Prong Plug, Integral Lamp(1)* Bright Stik, Gro & Sho, Lamp-In-Holder Unit with Standard 2-Prong Plug, Integral Lamp (1)* Bright Stik, Blacklight Blue Lamp-In-Holder Unit with Standard 2-Prong Plug, Integral Lamp (1)* Case Qty Rated Life Hours 1,10 1,10 1,10 Warning Notices Footnotes Additional Information GERMICIDAL T4 G23 GH23 T6 2G11 5 9 11 13 18 36 55 3.35 5.71 8.46 6.69 8.8 16.33 21.1 16479 15877 15879 15881 15882 15883 15885 GBX5/UVC GBX9/UVC GBX11/UVC GBX13/UVC GBX18/UVC/2G11 GBX36/UVC/2G11 GBX55/UVC/2G11 100 100 100 100 40 40 25 8000 8000 8000 8000 8000 8000 8000 3.35 5.71 8.46 6.7 12.8 16.33 21.1 42935 42936 42937 42938 42939 42940 42941 F9BX BL G23 F11BX BL G23 F13BX BL GX23 F26DBX BL G24d-3 F24BX BL 2G11 F36BX BL 2G11 F55BX BL 2G11 10 10 10 10 10 10 10 10000 10000 10000 10000 10000 10000 10000 Clear, Preheat, 2 Pin Internal Starter, UVC Source Clear, Preheat, 2 Pin Internal Starter, UVC Source Clear, Preheat, 2 Pin Internal Starter, UVC Source Clear, Preheat, 2 Pin Internal Starter, UVC Source Clear, UVC Source Clear, UVC Source Clear, UVC Source 106 106 106 106 106 106 106 9, 16 9, 16 9, 16 9, 16 9, 16 9, 16 9, 16 Blacklight UVA Source 2 pin Internal Starter Blacklight UVA Source 2 pin Internal Starter Blacklight UVA Source 2 pin Internal Starter Blacklight UVA Source 4 Pin Electronic Blacklight UVA Blacklight UVA Blacklight UVA 104 104 104 104 104 104 104 8 8 8 8 8 8 8 BLACKLIGHT T4 G23 GX23 T4 G24d-3 T6 2G11 5 11 13 26 24 36 55 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering ✹ TLCP Compliant Plug-Ins B ▲ EOL Protection Plug-Ins ★ Energy Star Screw-Ins 5-13 Compact Fluorescent Lamps FOOTNOTES # Footnote 1 Fluorescent lamp lumens decline during life. 2 Based on 60Hz reference circuit. 3 10-watt, 16-watt and 28-watt 2D® lamps may be operated in any position. 21-watt, 38-watt, 39-watt and 55-watt 2D® lamps must be used with the leg marked (a) in the diagram below the bend (b), in order to avoid overheating the end of the cap marked (c). 4 Life ratings for the F18BX preheat lamps are based on operating the lamp at 3hrs. per start on a preheat type circuit. Operation on rapid start and instant start ballasts is not recommended. 5 Cold cathode resistance is approximately 6.0 Ohms. 6 4-Pin lamp minimum starting temperature is a function of the ballast. Most ballasts are rated with a minimum starting temperature of 50°F (10°C). Ballasts are also available that provide reliable starting to 0°F (-18°C) and -20°F (-29°C). 7 Most one piece self ballasted lamps for incandescent sockets and plug-in lamps with screw-in adapters do not work with clip-on shades. 8 Lumens on one piece self ballasted lamp systems are measured base up. 9 Best performance if operated base up and at 77°F (25°C) ambient temperature. 10 Use only on 120V, 60Hz circuits. Do not use on dimming circuits, photocells or timers. Do not use in wet locations. 11 Adapters rated at 40,000 hours life. 12 Amalgam products experience stable brightness over a wider temperature range and in various operating positions. 13 Life ratings are based on operating the lamp at 3hrs. per start on a rapid start type ballast. Life rating on a preheat or instant start ballast is 25% lower. 14 Use only on 120V, 60Hz circuits. Do not use on with photocells or timers. Do not use in wet locations. 15 These lamps are only recommended for use with single lamp ballasts or parallel wired 2-lamp ballasts. 16 UL Listed for wet locations. Use only on 120V, 60Hz circuits. Do not use on dimming circuits, photocells or timers. 17 Max. bulb wall temperature not to exceed 180°C. Consult GE sales representative for further information. b c a WARNING AND CAUTION NOTICES 151 CAUTION Lamp may shatter and cause injury if broken • Remove and install by grasping only plastic portion of the lamp 152 CAUTION Risk of electric shock • Do not use where directly exposed to water • Do not open - no user serviceable parts inside Lamp may shatter and cause injury if broken • Remove and install by grasping only plastic portion of the lamp This product complies with Part 18 of the FCC Rules, but may cause interference to radios, televisions, wireless telephones, and remote controls. Avoid placing this product near these devices. If interference occurs, move the product away from the device or plug either into a different outlet. Do not install this product near maritime safety equipment or other critical navigation or communication equipment operating between 0.45-30 MHz. Not intended for use with emergency exit fixtures or lights, electronic timers, photocells, dimmers, or in totally enclosed recessed fixtures. 153 CAUTION Risk of electric shock • Do not use where directly exposed to water • Do not open - no user serviceable parts inside Lamp may shatter and cause injury if broken • Remove and install by grasping only plastic portion of the lamp This product complies with Part 18 of the FCC Rules, but may cause interference to radios, televisions, wireless telephones, and remote controls. Avoid placing this product near these devices. If interference occurs, move the product away from the device or plug either into a different outlet. Do not install this product near maritime safety equipment or other critical navigation or communication equipment operating between 0.45-30 MHz. Not intended for use with emergency exit fixture or lights, electronic timers, photocells, or with dimmers 154 CAUTION Risk of electric shock • Do not use where directly exposed to water • Do not open - no user serviceable parts inside Lamp may shatter and cause injury if broken • Remove and install by grasping only plastic portion of the lamp This product complies with Part 18 of the FCC Rules, but may cause interference to radios, televisions, wireless telephones, and remote controls. Avoid placing this product near these devices. If interference occurs, move the product away from the device or plug either into a different outlet. Do not install this product near maritime 5-14 safety equipment or other critical navigation or communication equipment operating between 0.45 - 30 MHz. Not intended for use with emergency exit fixtures or lights, in totally enclosed recessed fixtures, or with dimmers 155 CAUTION Risk of electric shock • Do not use where directly exposed to water • Do not open - no user serviceable parts inside Lamp may shatter and cause injury if broken • Remove and install by grasping only plastic portion of the lamp This product complies with Part 18 of the FCC Rules, but may cause interference to radios, televisions, wireless telephones, and remote controls. Avoid placing this product near these devices. If interference occurs, move the product away from the device or plug either into a different outlet. Do not install this product near maritime safety equipment or other critical navigation or communication equipment operating between 0.45 - 30 MHz. Not intended for use with emergency exit fixtures or lights, electronic timers, photocells, in totally enclosed recessed fixtures, or with dimmers 156 CAUTION Risk of electric shock • Do not use where directly exposed to water • Do not open - no user serviceable parts inside Lamp may shatter and cause injury if broken • Remove and install by grasping only plastic portion of the lamp This product complies with Part 18 of the FCC Rules, but may cause interference to radios, televisions, wireless telephones, and remote controls. Avoid placing this product near these devices. If interference occurs, move the product away from the device or plug either into a different outlet. Do not install this product near maritime safety equipment or other critical navigation or communication equipment operating between 0.45-30 MHz. Not intended for use with emergency exit fixtures or lights, electronic timers, photocells, or in totally enclosed recessed fixtures. 157 CAUTION Risk of electric shock • Do not open - no user serviceable parts inside • Do not use where directly exposed to water or outdoors without an enclosed fixture This product complies with Part 18 of the FCC Rules, but may cause interference to radios, televisions, wireless telephones, and remote controls. Avoid placing this product near these devices. If interference occurs, move the product away from the device or plug either into a different outlet. Do not install this product near maritime safety equipment or other critical navigation or communication equipment operating between 0.45-30 MHz. Not intended for use with emergency exit fixtures or lights, electronic timers, photocells, or with dimmers. For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering ✹ TLCP Compliant Plug-Ins B ▲ EOL Protection Plug-Ins ★ Energy Star Screw-Ins Compact Fluorescent Lamps WARNING AND CAUTION NOTICES (CONTINUED) 158 CAUTION Risk of electric shock • Do not open - no user serviceable parts inside • Do not use where directly exposed to water or outdoors without an enclosed fixture This product complies with Part 18 of the FCC Rules, but may cause interference to radios, televisions, wireless telephones, and remote controls. Avoid placing this product near these devices. If interference occurs, move the product away from the device or plug either into a different outlet. Do not install this product near maritime safety equipment or other critical navigation or communication equipment operating between 0.45-30 MHz. Not intended for use with emergency exit fixtures or lights, electronic timers, photocells, dimmers, or in totally enclosed recessed fixtures. • Do not use where directly exposed to water • Do not open - no user serviceable parts inside • Use indoors only Lamp may shatter and cause injury if broken • Remove and install by grasping only plastic portion of the lamp This product complies with Part 18 of the FCC Rules, but may cause interference to radios, televisions, wireless telephones, and remote controls. Avoid placing this product near these devices. If interference occurs, move the product away from the device or plug either into a different outlet. Do not install this product near maritime safety equipment or other critical navigation or communication equipment operating between 0.45-30 MHz. Not intended for use with emergency exit fixtures or lights, electronic timers, photocells, in totally enclosed recessed fixtures, or with dimmers. Added weight may cause instability of free-standing portable lamps. Use only with portable lamps in which the distance from the bottom of the base to the top of the lamp holder does not exceed three times the base width. Use only with portable lamps which are provided with lamp shades. 159 163 CAUTION Risk of electric shock • Do not open - no user serviceable parts inside • Do not use in wet locations • Use indoors only Risk of fire • Do not use this adapter on dimmers, electronic timers, or photocells CAUTION Risk of electric shock • Do not use where directly exposed to water • Do not open - no user serviceable parts inside • Use indoors only Lamp may shatter and cause injury if broken • Remove and install by grasping only plastic portion of the lamp Added weight may cause instability of free-standing portable lamps. Use only with portable lamps in which the distance from the bottom of the base to the top of the lamp holder does not exceed three times the base width and which are provided with lamp shades. Not intended for use with emergency exit fixtures or lights. 160 CAUTION Risk of electric shock • Do not use where directly exposed to water • Do not open - no user serviceable parts inside Lamp may shatter and cause injury if broken • Remove and install by grasping only plastic portion of the lamp This product may cause interference to radio equipment operating in the frequency range of 2.2 - 2.8 MHz. Avoid placing this product near these devices. To reduce the possibility of radio interference to maritime safety communications, this device should not be installed: 1) On board cargo vessels of more than 300 tons 2) On board cargo vessels carrying more than 12 passengers for hire 3) At any medium frequency public coast station Further, installation is not recommended on board vessels equipped with medium frequency, single sideband marine radios. If interference occurs, move this product away from the device or plug either into a different outlet. Such intereference complaints should be reported to: Application Solutions at General Electric Company, 1975 Noble Road, Cleveland, Ohio 44112, or call toll free (800) 435-4448 from 8:00 am to 6:00 pm EST. Not intended for use with emergency exit fixtures or lights, electronic timers, photocells, dimmers, or in totally enclosed recessed fixtures. 161 CAUTION Risk of electric shock • Do not use where directly exposed to water • Do not open - no user serviceable parts inside • Use indoors only Lamp may shatter and cause injury if broken • Remove and install by grasping only plastic portion of the lamp This product complies with Part 18 of the FCC Rules, but may cause interference to radios, televisions, wireless telephones, and remote controls. Avoid placing this product near these devices. If interference occurs, move the product away from the device or plug either into a different outlet. Do not install this product near maritime safety equipment or other critical navigation or communication equipment operating between 0.45-30 MHz. Not intended for use with emergency exit fixtures or lights, electronic timers, photocells, in totally enclosed recessed fixtures, or with dimmers. Use only with portable lamps which are provided with lamp shades. Added weight may cause instability of free-standing portable lamps. Use only with portable lamps in which the distance from the bottom of the base to the top of the lamp holder does not exceed three times the base width or with portable lamps which are provided with lamp shades. Not intended for use with emergency exit fixtures or lights, electronic timers, photocells, in totally enclosed recessed fixtures, or with dimmers. 164 CAUTION Risk of electric shock • Do not use where directly exposed to water • Do not open - no user serviceable parts inside • Use indoors only Lamp may shatter and cause injury if broken • Remove and install by grasping only plastic portion of the lamp This product complies with Part 18 of the FCC Rules, but may cause interference to radios, televisions, wireless telephones, and remote controls. Avoid placing this product near these devices. If interference occurs, move the product away from the device or plug either into a different outlet. Do not install this product near maritime safety equipment or other critical navigation or communication equipment operating between 0.45-30 MHz. Not intended for use with emergency exit fixtures or lights, in totally enclosed recessed fixtures, or with dimmers. Added weight may cause instability of free-standing portable lamps. Use only with portable lamps in which the distance from the bottom of the base to the top of the lamp holder does not exceed three times the base width. Use only with portable lamps which are provided with lamp shades. 165 CAUTION Risk of electric shock • Do not open - no user serviceable parts inside • Do not use where directly exposed to water or outdoors without an enclosed fixture This product complies with Part 18 of the FCC Rules, but may cause interference to radios, televisions, wireless telephones, and remote controls. Avoid placing this product near these devices. If interference occurs, move the product away from the device or plug either into a different outlet. Do not install this product near maritime safety equipment or other critical navigation or communication equipment operating between 0.45-30 MHz. Not intended for use with emergency exit fixtures or lights, electronic timers, photocells or in totally enclosed recessed fixtures. 166 CAUTION Risk of electric shock This product complies with Part 18 of the FCC Rules, but may cause interference to radios, televisions, wireless telephones, and remote controls. Avoid placing this product near these devices. If interference occurs, move the product away from the device or plug either into a different outlet. Do not install this product near maritime safety equipment or other critical navigation or communication equipment operating between 0.45-30 MHz. Not intended for use with emergency exit fixtures or lights, electronic timers, photocells, or with dimmers. 162 CAUTION Risk of electric shock For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering ✹ TLCP Compliant Plug-Ins B ▲ EOL Protection Plug-Ins ★ Energy Star Screw-Ins 5-15 Compact Fluorescent Lamps CFL CROSS REFERENCE GE Description Generic Description Osram/Sylvania Description Philips Description GE Description Generic Description Osram/Sylvania Description Philips Description ORDER THIS IF YOU CURRENTLY USE GE LAMP THESE LAMPS ® LOW WATTAGE BIAX 2-PIN ORDER THIS IF YOU CURRENTLY USE GE LAMP THESE LAMPS ® DOUBLE BIAX 2-PIN F5BX/SPX27 F5BX/SPX41 F7BX/SPX27 F7BX/SPX35 F7BX/SPX41 F9BX/SPX27 F9BX/SPX35 F9BX/SPX41 F13BX/SPX27 F13BX/SPX30 F13BX/SPX35 F13BX/SPX41 F13BX/SPX50 F13BX/E/827 F13BX/E/830 F13BX/E/835 F13BX/E/841 F13BX/E/850 F9DBX23T4/SPX27 F9DBX23T4/841 F13DBX23T4/SPX27 F13DBX23T4/SPX30 F13DBX23T4/SPX35 F13DBX23T4/SPX41 F13DBXT4/SPX27 F13DBXT4/SPX30 F13DBXT4/SPX35 F13DBXT4/SPX41 F18DBXT4/SPX27 F18DBXT4/SPX30 F18DBXT4/SPX35 F18DBXT4/SPX41 F26DBXT4/SPX27 F26DBXT4/SPX30 F26DBXT4/SPX35 F26DBXT4/SPX41 F26DBX/E/827 F26DBX/E/830 F26DBX/E/835 F26DBX/E/841 CFT5W/G23/827 CFT5W/G23/841 CFT7W/G23/827 CFT7W/G23/835 CFT7W/G23/841 CFT9W/G23/827 CFT9W/G23/835 CFT9W/G23/841 CFT13W/G23/827 CFT13W/G23/830 CFT13W/G23/835 CFT13W/G23/841 CFT13W/G23/850 CFT13W/G23/827 CFT13W/G23/835 CFT13W/G23/830 CFT13W/G23/841 CFT13W/G23/850 CF5DS/827 CFDS/841 CF7DS/827 CF7DS/835 CF7DS/841 CF9DS/827 CF9DS/835 CF9DS/841 CF13DS/827 CF13DS/830 CF13DS/835 CF13DS/841 CF13DS/850 — — — — — PL-S 5W/827 — PL-S 7W/827 PL-S 7W/835 PL-S 7W/841 PL-S 9W/827 PL-S 9W/835 PL-S 9W/841 PL-S 13W/827 PL-S 13W/830 PL-S 13W/835 PL-S 13W/841 PL-S 13W/850 — — — — — FT18DL/830 FT18DL/835 FT18DL/841 FT18DL/830/RS FT18DL/835/RS FT18DL/841/RS — FT24DL/830 FT24DL/835 FT24DL/841 FT36DL/830 FT36DL/835 FT36DL/841 FT40DL/830/RS FT40DL/835/RS FT40DL/841/RS — — — — FT55DL/830 FT55DL/835 FT55DL/841 PL-L 18W/830 PL-L 18W/835 PL-L 18W/841 PL-L 18W/830 PL-L 18W/835 PL-L 18W/841 — PL-L 24W/830 PL-L 24W/835 PL-L 24W/841 PL-L 36W/830 PL-L 36W/835 PL-L 36W/841 PL-L 40W/830/RS/IS PL-L 40W/835/RS/IS PL-L 40W/841/RS/IS — PL-L 50W/830/RS PL-L 50W/835/RS PL-L 50W/841/RS — — — HIGH LUMEN BIAX® F18BX/SPX30 F18BX/SPX35 F18BX/SPX41 F18BX/SPX30/RS F18BX/SPX35/RS F18BX/SPX41/RS F18BX/SPX65/RS F27BX/SPX3/RS F27BX/SPX35/RS F27BX/SPX41/RS F39BX/SPX3/RS F39BX/SPX3/RS F39BX/SPX3/RS F40/30BX/SPX30 F40/30BX/SPX35 F40/30BX/SPX41 F40/30BX/SPX50/RS F50/30BX/SPX30/RS F50/30BX/SPX35/RS F50/30BX/SPX41/RS F55BX/830 F55BX/835 F55BX/841 5-16 FT18W/2G11/830 FT18W/2G11/835 FT18W/2G11/841 FT18W/2G11/RS/830 FT18W/2G11/RS/835 FT18W/2G11/RS/841 FT18W/2G11/RS/865 FT24W/2G11/830 FT24W/2G11/835 FT24W/2G11/841 FT36W/2G11/830 FT36W/2G11/835 FT36W/2G11/841 FT40W/2G11/RS/830 FT40W/2G11/RS/835 FT40W/2G11/RS/841 FT40W/2G11/RS/850 FT50W/2G11/RS/830 FT50W/2G11/RS/835 FT50W/2G11/RS/841 FT55W/2G11/RS/830 FT55W/2G11/RS/835 FT55W/2G11/RS/841 CF9DD/827 — CF13DD/827 CF13DD/830 CF13DD/835 CF13DD/841 — — — — CF18DD/827 CF18DD/830 CF18DD/835 CF18DD/841 CF26DD/827 CF26DD/830 CF26DD/835 CF26DD/841 — — — — — — PL-C 13W/827/USA PL-C 13W/830/USA PL-C 13W/835/USA PL-C 13W/841/USA PL-C 13W/827 PL-C 13W/830 — — PL-C 18W/827 PL-C 18W/830 PL-C 18W/835 PL-C 18W/841 PL-C 26W/827 PL-C 26W/830 PL-C 26W/835 PL-C 26W/841 — — — — CF13DD/E/827 CF13DD/E/830 CF13DD/E/835 CF13DD/E/841 CF18DD/E/827 CF18DD/E/830 CF18DD/E/835 CF18DD/E/841 CF26DD/E/827 CF26DD/E/830 CF26DD/E/835 CF26DD/E/841 PL-C 13W/827/4P PL-C 13W/830/4P PL-C 13W/835/4P PL-C 13W/841/4P PL-C 18W/827/4P PL-C 18W/830/4P PL-C 18W/835/4P PL-C 18W/841/4P PL-C 26W/827/4P PL-C 26W/830/4P PL-C 26W/835/4P PL-C 26W/841/4P DOUBLE BIAX® 4-PIN F13DBX/SPX27/4P F13DBX/SPX30/4P F13DBX/SPX35/4P F13DBX/SPX41/4P F18DBX/SPX27/4P F18DBX/SPX30/4P F18DBX/SPX35/4P F18DBX/SPX41/4P F26DBX/SPX27/4P F26DBX/SPX30/4P F26DBX/SPX35/4P F26DBX/SPX41/4P For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering ✹ TLCP Compliant Plug-Ins B CFQ9W/G23/827 CFQ9W/G23/841 CFQ13W/GX23/827 CFQ13W/GX23/830 CFQ13W/GX23/835 CFQ13W/GX23/841 CFQ13W/G24d/827 CFQ13W/G24d/830 CFQ13W/G24d/835 CFQ13W/G24d/841 CFQ18W/G24d/827 CFQ18W/G24d/830 CFQ18W/G24d/835 CFQ18W/G24d/841 CFQ26W/G24d/827 CFQ26W/G24d/830 CFQ26W/G24d/835 CFQ26W/G24d/841 CFQ26W/G24d/827 CFQ26W/G24d/830 CFQ26W/G24d/835 CFQ26W/G24d/841 CFQ13W/G24q/827 CFQ13W/G24q/830 CFQ13W/G24q/835 CFQ13W/G24q/841 CFQ18W/G24q/827 CFQ18W/G24q/830 CFQ18W/G24q/835 CFQ18W/G24q/841 CFQ26W/G24q/827 CFQ26W/G24q/830 CFQ26W/G24q/835 CFQ26W/G24q/841 ▲ EOL Protection Plug-Ins ★ Energy Star Screw-Ins Compact Fluorescent Lamps CFL CROSS REFERENCE GE Description Generic Description ORDER THIS GE LAMP TRIPLE BIAX® 4-PIN Osram/Sylvania Description Philips Description IF YOU CURRENTLY USE THESE LAMPS F13TBX/SPX27/A/4P CFTR13W/GX24q/827 F13TBX/SPX27/A/4P CFTR13W/GX24q/830 F13TBX/SPX27/A/4P CFTR13W/GX24q/835 F13TBX/SPX27/A/4P CFTR13W/GX24q/841 F18TBX/SPX27/A/4P CFTR18W/GX24q/827 F18TBX/SPX30/A/4P CFTR18W/GX24q/830 F18TBX/SPX35/A/4P CFTR18W/GX24q/835 F18TBX/SPX41/A/4P CFTR18W/GX24q/841 F26TBX/SPX27/A/4P CFTR26W/GX24q/827 F26TBX/SPX30/A/4P CFTR26W/GX24q/830 F26TBX/SPX35/A/4P CFTR26W/GX24q/835 F26TBX/SPX41/A/4P CFTR26W/GX24q/841 F32TBX/SPX27/A/4P CFTR32W/GX24q/827 F32TBX/SPX30/A/4P CFTR32W/GX24q/830 F32TBX/SPX35/A/4P CFTR32W/GX24q/835 F32TBX/SPX41/A/4P CFTR32W/GX24q/841 F42TBX/827/A/4P/EOLCFTR42W/GX24q/827 F42TBX/830/A/4P/EOLCFTR42W/GX24q/830 F42TBX/835/A/4P/EOLCFTR42W/GX24q/835 F42TBX/841/A/4P/EOL CFTR42W/GX24q/841 CF13DT/E/827 CF13DT/E/830 CF13DT/E/835 CF13DT/E/841 CF18DT/E/IN/827 CF18DT/E/IN/830 CF18DT/E/IN/835 CF18DT/E/IN/841 CF26DT/E/IN/827 CF26DT/E/IN/830 CF26DT/E/IN/835 CF26DT/E/IN/841 CF32DT/E/IN/827 CF32DT/E/IN/830 CF32DT/E/IN/835 CF32DT/E/IN/841 CF42DT/E/IN/827 CF42DT/E/IN/830 CF42DT/E/IN/835 CF42DT/E/IN/841 — — — — PL-T 18W/827/4P PL-T 18W/830/4P PL-T 18W/835/4P PL-T 18W/841/4P PL-T 26W/827/4P PL-T 26W/830/4P PL-T 26W/835/4P PL-T 26W/841/4P PL-T 32W/827/4P PL-T 32W/830/4P PL-T 32W/835/4P PL-T 32W/841/4P PL-T 42W/827/4P PL-T 42W/830/4P PL-T 42W/835/4P PL-T 42W/841/4P CF57DT/E/IN/827 CF57DT/E/IN/830 CF57DT/E/IN/835 CF57DT/E/IN/841 CF57DT/E/IN/850 — — — — — — — — — — — — — — — HIGH OUTPUT BIAX® 4-PIN F57QBX/827/A/4P/EOL CFM57W/GX24q/827 F57QBX/830/A/4P/EOL CFM57W/GX24q/830 F57QBX/835/A/4P/EOL CFM57W/GX24q/835 F57QBX/841/A/4P/EOL CFM57W/GX24q/841 F57QBX/850/A/4P/EOL CFM57W/GX24q/850 F70QBX/827/A/4P/EOL CFM70W/GX24q/827 F70QBX/830/A/4P/EOL CFM70W/GX24q/830 F70QBX/835/A/4P/EOL CFM70W/GX24q/835 F70QBX/841/A/4P/EOL CFM70W/GX24q/841 F70QBX/850/A/4P/EOL CFM70W/GX24q/850 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering ✹ TLCP Compliant Plug-Ins B ▲ EOL Protection Plug-Ins ★ Energy Star Screw-Ins 5-17 Compact Fluorescent Lamps GE ENHANCED PLUG-IN PRODUCT CONVERSION IF YOU USED TO ORDER GE PRODUCT: PC 37654 13575 37661 37846 13576 37659 37660 37651 13577 37652 37653 41645 41646 41649 41651 41652 14583 41757 17048 41758 20434 11671 14650 17612 42065 12409 13578 18844 10574 18556 20531 18557 12956 18559 20532 30035 10580 30037 30038 12860 12861 12863 12864 12865 12866 12869 5-18 PC Description F5BX/SPX27/827 F5BX/SPX27/CD F5BX/SPX41/840 F7BX/SPX27/827 F7BX/SPX27/CD F7BX/SPX35/835 F7BX/SPX41/840 F9BX/SPX27/827 F9BX/SPX27/CD F9BX/SPX35/835 F9BX/SPX41/840 F13BX/E/827 F13BX/E/830 F13BX/E/835 F13BX/E/841 F13BX/E850 F13BX/SPX27/CD F13BX/SPX35 100P F13BX/SPX35/835 F13BX/SPX41 100P F13BX/SPX41/840 F13BX/SPX50 F13BXSPX27/827 F13BXSPX30/830 F9DBX23T4/841 F9DBX23T4SPX27/8 F13DBX/SPX27/CD F13DBX23T4/SPX27 F13DBX23T4/SPX30 F13DBX23T4/SPX35 F13DBX23T4/SPX41 F13DBXT4/SPX27 F13DBXT4/SPX30 F13DBXT4/SPX35 F13DBXT4/SPX41 F13DBX/SPX27/4P F13DBX/SPX30/4P F13DBX/SPX35/4P F13DBX/SPX41/4P F18DBXT4/SPX27 F18DBXT4/SPX30 F18DBXT4/SPX35 F18DBXT4/SPX41 F18DBX/SPX27/4P F18DBX/SPX30/4P F18DBX/SPX35/4P NOW ORDER GE PRODUCT: New PC 97551 97552 97553 97554 97555 97556 97557 97558 97559 97560 97561 97562 97563 97564 97565 97566 97567 97568 97569 97570 97571 97572 97573 97574 97575 97576 97585 97586 97587 97588 97589 97590 97591 97592 97593 97594 97595 97596 97597 97577 97578 97579 97580 97598 97599 97600 New Description F5BX/827/ECO F5BX/827/CDECO F5BX/841/ECO F7BX/827/ECO F7BX/827/CDECO F7BX/835/ECO F7BX/841/ECO F9BX/827/ECO F9BX/827/CDECO F9BX/835/ECO F9BX/841/ECO F13BX/E/827/ECO F13BX/E/830/ECO F13BX/E/835/ECO F13BX/E/841/ECO F13BX/E/850/ECO F13BX/827/CDECO F13BX/835 100P F13BX/835/ECO F13BX/841 100P F13BX/841/ECO F13BX/850/ECO F13BX/827/ECO F13BX/830/ECO F9DBX23/841/ECO F9DBX23/827/ECO F13DBX/827/CD F13DBX23/827/ECO F13DBX23/830/ECO F13DBX23/835/ECO F13DBX23/841/ECO F13DBX/827/ECO F13DBX/830/ECO F13DBX/835/ECO F13DBX/841/ECO F13DBX/827/ECO4P F13DBX/830/ECO4P F13DBX/835/ECO4P F13DBX/841/ECO4P F18DBX/827/ECO F18DBX/830/ECO F18DBX/835/ECO F18DBX/841/ECO F18DBX/827/ECO4P F18DBX/830/ECO4P F18DBX/835/ECO4P IF YOU USED TO ORDER GE PRODUCT: PC 12870 46290 46291 46292 46294 35250 35237 35251 35252 35247 35235 35248 35236 34391 34395 34400 34387 47696 34392 34396 34405 34385 48869 34393 34397 34406 34381 48870 39377 39378 39379 39380 46312 46313 46314 46315 48861 48862 48863 48864 93404 48865 48866 48867 48868 93406 PC Description F18DBX/SPX41/4P F26DBX/E/827 F26DBX/E/830 F26DBX/E/835 F26DBX/E/841 F26DBXT4/SPX27 F26DBXT4/SPX30 F26DBXT4/SPX35 F26DBXT4/SPX41 F26DBXT4SPX27/4P F26DBXT4SPX30/4P F26DBXT4SPX35/4P F26DBXT4SPX41/4P F13TBX/SPX27/A/4 F13TBX/SPX30/A/4 F13TBX/SPX35/A/4 F13TBX/SPX41/A/4 F13TBX827/4P/EOL F18TBX/SPX27/A/4 F18TBX/SPX30/A/4 F18TBX/SPX35/A/4 F18TBX/SPX41/A/4 F18TBX827/4P/EOL F26TBX/SPX27/A/4 F26TBX/SPX30/A/4 F26TBX/SPX35/A/4 F26TBX/SPX41/A/4 F26TBX827/4P/EOL F32TBX/SPX27A/4P F32TBX/SPX30A/4P F32TBX/SPX35A/4P F32TBX/SPX41A/4P F42TBX827A4P/EOL F42TBX830A4P/EOL F42TBX835A4P/EOL F42TBX841A4P/EOL F57QBX/827/A/4P/EOL F57QBX/830/A/4P/EOL F57QBX/835/A/4P/EOL F57QBX/841/A/4P/EOL F57QBX/850/A/4P/EOL F70QBX/827/A/4P/EOL F70QBX/830/A/4P/EOL F70QBX/835/A/4P/EOL F70QBX/841/A/4P/EOL F70QBX/850/A/4P/EOL For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering ✹ TLCP Compliant Plug-Ins B NOW ORDER GE PRODUCT: ▲ EOL Protection Plug-Ins New PC 97601 97602 97603 97604 97605 97606 97607 97608 97609 97610 97611 97612 97613 97619 97620 97621 97622 97623 97624 97625 97626 97627 97628 97614 97615 97616 97617 97618 97629 97630 97631 97632 97633 97634 97635 97636 48861 48862 48863 48864 93404 48865 48866 48867 48868 93406 ★ New Description F18DBX/841/ECO4P F26DBX/E/827/ECO F26DBX/E/830/ECO F26DBX/E/835/ECO F26DBX/E/841/ECO F26DBX/827/ECO F26DBX/830/ECO F26DBX/835/ECO F26DBX/841/ECO F26DBX/827/ECO4P F26DBX/830/ECO4P F26DBX/835/ECO4P F26DBX/841/ECO4P F13TBX/827/A/ECO F13TBX/830/A/ECO F13TBX/835/A/ECO F13TBX/841/A/ECO F13TBX827/4P/ECO F18TBX/827/A/ECO F18TBX/830/A/ECO F18TBX/835/A/ECO F18TBX/841/A/ECO F18TBX827/4P/ECO F26TBX/827/A/ECO F26TBX/830/A/ECO F26TBX/835/A/ECO F26TBX/841/A/ECO F26TBX827/4P/ECO F32TBX/827/A/ECO F32TBX/830/A/ECO F32TBX/835/A/ECO F32TBX/841/A/ECO F42TBX/827/A/ECO F42TBX/830/A/ECO F42TBX/835/A/ECO F42TBX/841/A/ECO F57QBX/827/A/ECO F57QBX/830/A/ECO F57QBX/835/A/ECO F57QBX/841/A/ECO F57QBX/850/A/ECO F70QBX/827/A/ECO F70QBX/830/A/ECO F70QBX/835/A/ECO F70QBX/841/A/ECO F70QBX/850/A/ECO Energy Star Screw-Ins Stage and Studio Lamps QUARTZLINE® TUNGSTEN HALOGEN .................................. 6-7 QUARTZLINE® TUNGSTEN HALOGEN HIGH VOLTAGE ....... 6-8 CINEMA LAMPS Fluorescent Lamps ............................................................................................................... 6-9 Fluorescent covRguard® Lamps ..................................................................................... 6-9 Fluorescent Biax® ...............................................................................................................6-10 CSR METAL HALIDE LAMPS Discharge-CSR/CSD (Daylight) Metal Halide, Single-Ended Cold Start...............6-11 Discharge-CSR (Daylight) Metal Halide, Single-Ended Short Arc ..........................6-11 Discharge-CSR (Daylight) Metal Halide, Single-Ended Hot Restrike ....................6-11 Discharge-CSR (Daylight) Metal Halide, Double-Ended Hot Restrike ..................6-11 CSR (Daylight) Metal Halide, Single-Ended Hot Restrike UV-Control ...................6-11 ANSI CODES ...........................................................................6-12 For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose the one with the lowest watts. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering B 6-1 Stage and Studio Lamps BULB IDENTIFICATION DIA. DIA. MOL MOL LCL DIA: Diameter of bulb at widest point. MOL: Maximum Overall Length including base or pins. LCL: Distance between the center of the arc tube and the Light Center Length reference plane. Note: Lamp drawings are not drawn to scale. Be sure to check size and dimension information when identifying each lamp. To convert inches to millimeters, multiply the dimension (in inches) by 25.4 (i.e. inches x 25.4 = millimeters). LAMP LOCATOR T12 G13 T8 G13 T12 Med Pf T14 Med 2-Pin (G9.5) Incandescent Lamps Biax® 2G11 Fluorescent Cinema Lamps T3, T5 R7s T4 R7s T6 R7s PAR36 Ferrule G6, G7 2-Pin Prefocus (GX9.5 / GY9.5) PAR36 Scrw Term PAR64 Extended Mog End Prefocus PS52 Mog (E39) T4, T6 T4, T6, T7, T8 Med 2-Pin Med Prefocus (G9.5) (P28s) T4 T5 T6 T6 Mini-Cand 2-Pin Prefocus Med 2-Pin Special (GX9.5 / GY9.5) (G9.5) Quartzline® Tungsten Halogen 6-2 For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose the one with the lowest watts. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering B T7, T8, T10 Mog Prefocus (P40s) Stage and Studio Lamps T7 T7 Med 2-Pin Med BiPost (G9.5) (G22) T20 Mog BiPost (G38) T24 Mog BiPost (G38) T26 GX38 T32 GX38 T7 Mog BiPost (G38) T8 2-Pin Prefocus (GX9.5) T8 GX9.5 T7, T8 Med BiPost (G22) T8 Med 2-Pin (G9.5) T8 Mog (E39) T8, T10 Mog BiPost (G38) T12 Med Prefocus (P28s) Quartzline® Tungsten Halogen (Continued) T4.5 X515 T6.5 SFc10-4 T9 SFc10.5-6 G7 GY9.5 Short Arc Discharge T9, T12 SFa 21-12 T16, T22.5 25x51 Cyl 165mm Lead T5, T6 GZX9.5, GZY9.5 T9.5 G22 T13 G38 T24 G38 T32 G38 T28 30x70 Cyl 165mm Lead Double-Ended Hot Restrike Single-Ended Hot Restrike CSR Metal Halide Lamps For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose the one with the lowest watts. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering B 6-3 Stage and Studio Lamps LAMP LOCATOR (CONTINUED) PAR64 Extended Mog End Prefocus T6 T6, T8 T8 T8 T8 T8 T10, T11 T10 T6 Med 2-Pin Med Prefocus Special 2-Pin Prefocus 2-Pin Prefocus Med BiPost Med Prefocus 2-Pin Prefocus Mog BiPost (G9.5) (P28s) (GX9.5) (GX9.5) (G22) (P28s) (GX9.5) (G38) T3 R7s T11 GY9.5 Quartzline® Tungsten Halogen High Voltage FILAMENT IDENTIFICATION 2C8 2CC-8 C-2V CC-2V C-5 C-6 CC-6 C-7A CC-8 C-9 C-13 C-13D BASE IDENTIFICATION Can DC Bay 2-Pin (Round) GX5.3 GX9.5 GY9.5 2-Pin Pf Min BiPin GY16 G5.3 G9.5 Mini Cand Recessed E11 Single Contact R7s SFa 21-12 SFc 10-4 SFc 10.5-6 X515 Ferrule Screw Terminal Med Pf P28s Med Side Pr 6-4 Med Screw E26 Cylinder Mog Pf P40s Ext. Mog End Pr GX16d Mog End Pr GX16d Med BiPost G22 Mogul BiPost G38 Special For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose the one with the lowest watts. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering B Mog Screw E39 Stage and Studio Lamps INTRODUCTION GE has been a leading supplier to stage and studio users for many decades, and continues its pioneering work in the development of new and innovative light sources. The primary change in recent years has been the migration from glass to quartz as the standard bulb material. The higher melting point of quartz enables bulb envelopes to be reduced in size and the halogen fillings to be run at higher pressures, leading to smaller, lighter, brighter, more energyefficient and more reliable lamps. GE ’s comprehensive range of single- and double-ended lamps is complemented by a group of PAR lamps, where the light source is enclosed in a sealed reflector unit. The beam patterns of PAR lamps range from very narrow spot to wide-angle floods. This ensures consistency from lamp to lamp, interchangeability to suit the beam pattern needs of the moment and instant replaceability without the need to refocus and re-aim fixtures. The sealed beam design prolongs the life of the inner lamp as well as protecting it from dust, vapor and other hazards, thereby ensuring high lumen maintenance over the life of the lamp. PAR lamps may be used with very simple, lightweight, economical fixtures. GENERAL INFORMATION OPERATIONAL CHARACTERISTICS CHROMISE SEAL PROTECTION Quartz halogen lamps are designed to be operated within close voltage tolerances, and excessive voltage can lead to drastically shortened life, albeit with significantly higher light output. A second important variable is temperature. The tungsten halogen cycle does not operate properly below about 482°F (250°C) and quartz may begin to devitrify above about 1832°F (1000°C). Bulb envelopes should therefore be held in the range 482-1472°F (250-800°C). The contact pins are plated to ensure good electrical connection with the lampholder. However, at temperatures above 350°C, the plating may lose adhesion, leading to deterioration in contact and possibly local hot spots, arcing and consequent irreparable damage to both lamp and holder. Note that if there is evidence that this has occurred, the lampholder should be replaced before the next lamp is fitted, otherwise it is likely to fail prematurely for the same reason. Lamps normally fail by fusing of the filament. This is often followed by arcing, leading to very high currents which can cause the envelope and seals to fail and the lamp to shatter. A quick-acting, high-breaking capacity fuse should therefore be connected to the supply line in all applications. Suitable types are given in IEC 127, 241 and 269. Many Quartzline® Stage/Studio lamps have a special chromised seal protection, which allows lamp seal temperatures up to 500° C (vs traditional 350° C), which increases life and reliability. If the package does not have this seal, lamp base temperatures for Quartzline® lamps should not exceed 350°C because, above that point, lead wires in the sealing area will deteriorate, and base cement can loosen, both causing premature lamp failure. Note overvoltaging a lamp will increase the seal heat. LAMP CODES GE Stage & Studio lamps are coded as such: Lamp Description. This may be either an American National Standards Institute (ANSI) three letter code such as EJG, or a descriptive code in the general form Q750T3/4CL. ANSI codes are assigned to lamp specifications – mechanical, electrical and photometric characteristics – filed with the Institute. They ensure interchangeability among similarly coded lamps from different manufacturers. Most of these lamps are rated for 120-volt operation. In a few cases a pair of ANSI codes are given (e.g. BFL/BFK), where the first is the official code for the lamp and the second code describes lamps the specifications of which are met or exceeded. In such cases, the lamps may be used to replace lamps with either code. Base designations conform to IEC standards. PRODUCT INFORMATION GE CSR/CSD METAL HALIDE LAMPS New GE range of metal halide lamps for use in a variety of applications including TV and film, stage, concerts, photographic and large screen presentation and color simulation. • Excellent color rendering Ra >90 • Daylight color temperature, typically 6000K • Universal burning position • High efficiency up to 100 Lm/Watt • Hot restrike and dimmable with stable color temperature • Superior color stability • Excellent lumen maintenance • Use with electronic or AC magnetic ballast/ignitor control gear • Applications include inside and outside TV and film production, stage, concerts, sporting events, photographic studios, overhead and large screen projection and color simulation. GE CINEMA FLUORESCENT LAMPS • High CRI (Color Rendering Index)… traditional fluorescent lamps have not been widely used in photography and film making because of relatively low CRI and the prominent green spike found in typical fluorescent phosphors. GE Lighting Cinema 32 and Cinema 55 lamps have corrected these deficiencies with products that now have a CRI of 95 (out of 100 max.) and colors that respond to the spectral sensitivity curves of film and electronic imaging media. • Optional Shatter Resistance… GE Cinema 32 and 55 offer the option of GE’s exclusive covRguard® shatter resistance that helps contain glass fragments if the lamps are broken. Reduce the possibility of glass related injuries to irreplaceable talent, damage to expensive sets, contamination of delicate equipment or missing critical deadlines because GE offers shatter resistance. GE’s covRguard® process wraps the Cinema lamps in a full 15 ml thick casing of GE’s exclusive Lexan™ polycarbonate that helps contain the glass, phosphor and chemicals if the lamp is broken. Unlike other shatter-resistant lamps, GE’s covRguard® lamps require no assembly. For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose the one with the lowest watts. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering B 6-5 Stage and Studio Lamps PRODUCT INFORMATION (CONTINUED) • Superior Light Output… the GE covRguard® process offers maximum protection with minimal light loss… the lowest loss of initial light of other shielded products. • Dependable UV Blocking… the GE covRguard® process also offers excellent UV blocking. CovRguard® blocks 98% of the UV that is normally transmitted from an unprotected fluorescent lamp — all UVC, all UVB and most of UVA. This is critical for protecting expensive sets and wardrobe from the fading effects of UV exposure. • Chromaticity… the Cinema 32 has a chromaticity of X=.415 and Y=.377 with a CRI of 95. The Cinema 32 mixes well with both incandescent and quartz halogen light sources without color corrections. The Cinema 55 is a broad band spectrum daylight lamp with a chromaticity of X=.325 and Y=.321 and a CRI of 96. The Cinema 55 mixes well with ambient daylight and short arc discharge HID light sources without color corrections. For more detailed information on all GE Stage and Studio lighting order “Showbiz®” 2005, PC 23766 from your GE sales representative. HEADINGS IN THIS CATALOG SECTION The following terms and descriptions can help you when checking Stage/Studio lamp specifications and when ordering products. Within each product line, lamps are divided into families, within these families, lamps are then listed by wattage. Approximate CBCP (Center Beam Candlepower): Volts: Case Quantity: Lamp data is based on operation at rated voltage. Number of product units packed in a case. For reflector type lamps. Center Beam Candlepower is the intensity (candelas) at the center or maximum intensity of the beam. Color Temperature - Kelvins (K): A measure of the visual “warmth” or “coolness” of the light from the lamp. The higher the value, the whiter or “cooler” the light appears. Order Code: It is important to use this five-digit code when ordering to ensure that you receive the exact product you require. Filament Design: Filaments are designated by a letter combination in which C is a coiled wire filament, CC is a coiled wire that is itself wound into a larger coil, and SR is a straight ribbon filament. Numbers represent the type of filament-support arrangement. Watts: LIF Code: Energy used. To find actual energy used (kWh) multiply power (watts shown) x time divided by 1000. These are assigned by the Lighting Federation of London, U.K. They ensure electrical and mechanical interchangeability of similarly coded lamps. LIF codes are divided into groups according to the primary application of the lamps. Shape: Bulb shape followed by its size (the maximum diameter of the bulb expressed in eighths of an inch). The lamp‘s identification code. The type of base (ANSI). Watts Shape Order LIF Volts Code Code Base Maximum Overall Length in inches. LCL in.: Distance between the center of the filament and the Light Center Length reference plane, in inches. Lumens Initial: Initial light output. Description: Base: MOL in.: Lamp burning hours to median life expectancy. For reflector type lamps. The total angle of the directed beam (in degrees) to where the intensity of the beam falls to 50% or 10% of the maximum value as indicated. Color Beam Spread Case Lumens Temp. Filament 10% 50% Qty. Initial CBCP K Design MOL LCL Horiz. Vert. Horiz. Vert. Description Rated Life - Hours: Beam Spread: Footnotes: See pg 6-12. Rated Life Hours Footnotes 500 3, 12 ® QUARTZLINE TUNGSTEN HALOGEN 500 T6 Med Pf (P28s) 120 11966 T17 BTL-Q500T6/CL/P 12 11000 3000 C-13 5.25 2.18 BTL- Q500 T6/CL/P Identifies the lamp ANSI code. 6-6 Identifies the lamp’s wattage. Q=Quartz Halogen Identifies the lamp shape and the bulb diameter in eighths of inches. WHEN YOU DON’T KNOW THE LAMP DESCRIPTION 1. Identify bulb shape by using tables on pages 6-2 – 6-4. 2. Measure bulb diameter using ruler in Appendix section page A-1 to determine width in eighths of an inch. 3. Identify base type using table on page 6-4. 4. Find your lamp in the table containing the bulb shape, size and base. For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose the one with the lowest watts. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering B Stage and Studio Lamps Watts Shape Base Order LIF Volts Code Code Description Color Beam Spread Case Lumens Temp. Filament 10% 50% Qty. Initial CBCP K Design MOL LCL Horiz. Vert. Horiz. Vert. Rated Life Hours Footnotes 50 50 400 300 1000 75 400 400 2000 2000 500 150 150 2000 500 150 500 400 300 1500 300 1500 300 300 1500 300 2000 2000 25 30 100 100 100 30 30 400 100 100 200 400 400 400 300 2000 300 1500 300 2000 300 1500 12 12 2, 12 12 12 12 2, 12 2, 7, 12 12 8, 12 3, 12 3, 12 12 12 12 3, 12 12 2, 12 12 12 12 12 12 12 12 12 12 3, 12 3, 12 13 13 13 13 13 13 2, 12 12 7, 12 3, 12 2, 12 2, 12 2, 12 12 12 12 12 12 12 12 12 ® QUARTZLINE TUNGSTEN HALOGEN 200 300 350 375 T4 T8 T2 T6 Cand DC Bay BA15d 2-Pin Pf (GY9.5) R7S Special 120 120 120 115 420 G7 500 T3 2-Pin Pf (GY9.5) R7S 120 120 T4 T6 Med Pf (P28s) Mini-Cand (E11) Med Pf (P28s) 120 120 120 T7 T6 Med BiPost (G22) 120 Med 2-Pin (G9.5) 120 T8 T4 525 T3 550 T6 575 T6 2-Pin Pf (GY9.5) Med Pf (P28s) R7S Special Med 2-Pin (G9.5) 120 120 120 115 115 Special 115 120 600 T5 2-Pin Pf (GY9.5) 650 G6 2-Pin Pf (GX9.5) PAR36 Ferrule Screw Term T3 T4 T8 675 T3 750 T3 T6 120 120 120 120 R7S R7S 120 120 2-Pin Pf (GY9.5) R7S R7S 120 120 120 Med 2-Pin (G9.5) 120 Med Pf (P28s) 120 Special 115 14119 39781 CP81 20881 17608 18189 33934 23735 23734 P2/31 39135 47950 11966 T17 16465 30373 39768 39789 39623 CP82 39134 20883 17607 39730 11450 93428 93429 92431 92434 92433 92435 30475 34328 41668 41672 41673 41667 41669 41671 13895 30325 P2/6 30343 P2/6 39637 CP89 20884 23756 23755 39771 39770 92771 92773 39136 39137 92432 92770 FEV-Q200/4CL/DC FKW-Q300T8 FDF/HIR-Q350T2/4 HPL375/C 115V HPL375/LL/C 115V EKB-Q420/4CL/2PP FDF-Q500T3/4CL FDN-Q500T3/4 EGE-Q500CL/P EVR-Q500CL/MC BTL-Q500T6/CL/P BTM-Q500T64CL/2P EGN-Q500T8 EHD-Q500CL/TP EHC-Q500/5CL FRG-Q500T8 EGC-Q500/5CL/P EJG/HIR-Q525T2 -1 HPL550/C 77 V FLK/LL-Q575T6 FLK-Q575T6/4CL GLA-Q575T6/4CL GLC-Q575T6/5CL HPL575/C115V HPL575/LL/C 115V HPL575/C 120V HPL575/LL/C 120V FMR-Q600T5 EKD-Q650/3CL/2PP FAY-Q650PAR36/3D FCW-Q650PAR36/6 FCX-Q650PAR36/7 DWE-Q650PAR36/1 FBE-Q650PAR36/5D FBO-Q650PAR36/5 FCM/HIR-Q650T3/4 FAD-Q650T4/4CL FBX-Q650T4/4 FRK-Q650T8 FFT/HIR-Q675T3/4 EJG-Q750T3/4CL EMD-Q750T3/4 EHF-Q750/4CL EHG-Q750CL/TP GLD-Q750T6/4CL GLE-Q750T6/4CL EGF-Q750/4CL/P EGG-Q750CL/P HPL750/C 115V HPL750/LL/C 6 24 6 12 12 24 12 12 12 6 12 12 12 24 24 24 12 6 12 24 24 24 24 12 12 12 12 24 24 12 12 12 12 12 12 6 24 24 24 6 12 12 24 24 24 24 12 12 12 12 5500 6900 13250 10540 8000 11000 13250 12800 10450 10450 11000 13000 13000 10000 12700 13000 12700 20600 16170 12800 16500 13000 14500 16500 12360 16520 12360 12600 20000 36000 9000 24000 24000 36000 67000 25200 16500 16500 16900 26400 20600 19500 20000 15000 19000 17400 20400 15750 22000 16400 3200 3200 3200 3250 3050 3200 3200 3200 2950 2950 3000 3200 3200 2900 3150 3200 3150 3250 3250 2950 3200 3050 3200 3200 3050 3200 3050 3050 3300 5000 3200 3200 3200 5000 3400 3275 3200 3200 3200 3250 3200 3200 3200 3000 3200 3050 3200 3000 3200 3050 CC-2V C-13 C-8 4-C8 4-C8 CC-6 C-8 C-8 CC-8 CC-8 C-13 C-13 C-13 CC-8 CC-8 C-13 CC-8 C-8 4-C8 CC-8 CC-8 C-13D C-13D 4C-8 4C-8 4C-8 4C-8 CC-8 CC-6 C-7A C-7A C-7A C-7A C-7A C-8 CC-8 CC-8 C-13 C-8 C-8 C-8 CC-8 CC-8 C-13D C-13D CC-8 CC-8 4-C-8 4-C-8 2.43 3.54 4.68 4.17 4.17 2.5 4.68 4.68 6 3.62 5.25 5.25 5.51 4.1 4.1 3.54 6 4.68 4.17 4.1 4.1 4.1 4.1 4.2 4.2 4.2 4.2 3.4 2.5 2.75 2.75 2.75 2.75 2.75 2.75 4.68 3.13 3.13 3.54 6.56 4.68 4.68 4.1 4.1 4.1 4.1 6 6 4.17 4.17 1.37 1.81 2.37 2.37 1.43 3.5 2 2.18 2.18 2.5 2.37 2.37 1.81 3.5 2.37 2.37 2.37 2.37 2.37 2.37 2.37 2.37 2.37 2 1.43 25 60 40 40 25 25 1.81 2.37 2.37 2.37 2.37 3.5 3.5 2.37 2.37 15 55 30 30 15 15 For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose the one with the lowest watts. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering B B B B B 6-7 Stage and Studio Lamps Watts Shape Base Order LIF Volts Code Code Description Color Beam Spread Case Lumens Temp. Filament 10% 50% Qty. Initial CBCP K Design MOL LCL Horiz. Vert. Horiz. Vert. Rated Life Hours Footnotes 1, 3, 12 1, 11, 12 1, 11, 12 1, 3, 12 13 13 13 13 13 13 1, 13 1, 13 2, 12 2, 12 2, 7, 12 2, 12 12 7, 12 10, 12 12 12 12 12 10, 12 1, 3, 12 1, 12 1, 3, 12 1, 3, 12 1, 3, 12 1, 3, 12 13 13 13 1, 13 1, 13 2, 12 2, 7, 12 3, 12 1, 3, 12 2, 12 12 3, 12 1, 3, 12 3, 12 1, 4, 12 1, 4, 12 4, 12 12 12 ® QUARTZLINE TUNGSTEN HALOGEN (CONTINUED) 750 T7 Med BiPost (G22) Med Pf (P28s) Med 2-Pin (G9.5) 1000 PAR64 ExMogEndPr PS52 Mog (E39) ED37 Mog (E39) T3 R7S T5 R7S T6 Med 2-Pin (G9.5) Med Pf (P28s) T7 R7S Med 2-Pin (G9.5) Med 2-Pin (G9.5) Med Pf (P28s) Med BiPost (G22) Mog BiPost (G38) Mog Pf (P40s) 1200 PAR64 ExMogEndPr 1500 PS52 Mog (E39) ED37 Mog (E39) T4 R7S T8 T10 2000 T10 T8 T10 5000 T20 10000 T24 12000 T26 Mog Pf (P40s) Mog BiPost (G38) R7S Mog (E39) Mog BiPost (G38) Mog BiPost (G38) Mog Pf (P40s) Mog BiPost (G38) Mog BiPost (G38) GX38 120 39190 120 11953 11954 120 39680 120 13233 13229 13228 13227 13226 13225 120 39582 120 34377 120 23797 P2/28 33280 23792 P2/29 185 23788 120 30157 30374 120 39769 CP77 120 38853 38852 39138 120 33760 120 35853 120 39792 120 11955 120 39191 120 42697 120 12554 12553 120 34812 34810 34808 120 40357 120 34378 120 23841 41229 120 30522 120 37564 120 39790 P2/27 120 37086 120 39587 120 36636 120 12555 CP53 120 41736 CP29 120 24886 120 48770 EGR-Q750T7/4CL BTN-Q750T7/CL/2P BTP-Q750T7/4CL2P BWM-Q750T7/4CLTP FFN-Q1000PAR64/1 FFP-Q1000PAR64/2 FFR-Q1000PAR64/5 FFS-Q1000PAR64/6 FGM-Q1000PAR64/3 FGN-Q1000PAR647D DKZ/DSE-Q1000PS5 DSE/Q1000 FCM-Q1000T3/4CL FFT-Q1000T3/1CL FHM-Q1000T3/4 EJD-Q1000T3/3CL DXW-Q1000T5/4CL FBY-Q1000T5/4 FEL-Q1000/4CL EGJ-Q1000/4CL/P EGK-Q1000/4/P EGM-Q1000CL/P FER-Q1000T6/4CL FCV-Q1000/4 BWN-Q1000T7/4CL BTR-Q1000T74CL2P EGT-Q1000T7/4CL CYVQ1000T7/4CLBP BVT-Q1MT7/CL/MP BVV-Q1MT7/4CL/MP GFA-Q1200PAR64/5 GFB-Q1200PAR64/2 GFC-Q1200PAR64/1 DKX/DSFQ1500PS52 DSF/Q1500 FDB-Q1500T4/4CL FGT-Q1500T4/4 DTA-Q1500T8/4CL CXZ-Q1500T10/4CL FEY-Q2000T8/4CL BWF-Q2000/4CL BWA-Q2000/4CL/BP CYX-Q2000T10/4CL BVWQ2MT10/4CL/MP DPY-Q5000T20/4CL DTY-Q10M/T24/4CL Q12MT26/4CL 120V 12 21000 12 17600 12 21000 6 21000 6 6 6 6 6 6 12 28000 10 28000 12 28000 12 26400 12 27300 12 33600 24 28000 24 26000 24 27500 12 27500 12 26500 12 21500 6 27500 6 26500 24 28500 12 28500 12 28500 6 28500 6 24500 6 28500 6 6 6 12 41000 10 41000 12 41250 12 40200 6 41000 6 44500 12 57000 6 54000 6 54000 6 59000 6 59000 6 143000 4 290000 1 420000 400000 330000 125000 40000 200000 70000 160000 450000 540000 3200 3050 3200 3200 3200 3200 3200 3200 5200 5200 3200 3200 3200 3200 3200 3350 3200 3200 3200 3200 3200 3000 3200 3200 3200 3200 3200 3200 3050 3200 3200 3200 3200 3200 3200 3200 3200 3200 3200 3200 3200 3200 3200 3200 3200 3200 3400 C-13D C-13D C-13D C-13D C-7A C-7A C-7A C-7A C-7A C-7A CC-8 CC-8 C-8 C-8 C-8 C-8 CC-8 CC-8 CC-8 CC-8 CC-8 CC-8 CC-8 CC-8 C-13D C-13D C-13D C-13D C-13D C-13D C-7A C-7A C-7A C-8 C-8 C-8 C-8 C-13D C-13 CC-8 CC-8 CC-8 C-13 C-13 C-13 C-13 C-13 5 4.75 4.75 4.5 6 6 6 6 6 6 13 13 4.68 6.56 4.68 4.68 3.75 3.75 4.1 6 6 6 5.62 4.1 4.5 4.75 5 8 7.25 7.25 6 6 6 13 13 6.56 6.56 7.87 8.5 5.62 7.5 8.25 8.5 8.46 11 15.75 16.14 2.5 2.18 2.18 2.37 5.25 5 5 3.93 6.5 10 10 200 500 200 200 800 800 800 800 200 200 750 750 400 400 400 100 150 150 300 300 300 2000 500 375 250 250 250 200 500 200 400 400 400 1000 1000 400 400 300 400 400 500 500 350 350 500 300 150 4.2 4.2 2.37 2.37 300 1500 24 26 44 71 24 43 10 14 21 45 12 20 12 14 28 48 13 27 6 7 12 24 6 11 22 16 14 36 18 16 13 8 8 24 10 10 9.5 9.5 2.37 3.5 3.5 3.5 2.37 2.37 2.18 2.5 5 3.93 3.93 3.43 5 QUARTZLINE® TUNGSTEN HALOGEN HIGH VOLTAGE 575 T6 6-8 Special 230 37128 37817 HPL575 HPL575/LL 230V 12 14900 12 11780 3200 6C-8 3050 6C-8 For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose the one with the lowest watts. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering B Stage and Studio Lamps Watts Shape Base Order LIF Volts Code Code Description Color Beam Spread Case Lumens Temp. Filament 10% 50% Qty. Initial CBCP K Design MOL LCL Horiz. Vert. Horiz. Vert. Rated Life Hours Footnotes 250 300 300 300 300 300 300 130 130 400 400 400 150 150 12 12 12 13 13 13 2, 12 4, 12 4, 12 4, 12 4, 12 4, 12 4, 12 4, 12 ® QUARTZLINE TUNGSTEN HALOGEN HIGH VOLTAGE (CONTINUED) 600 T6 Med 2-Pin (G9.5) 750 T6 Special 1000 T6 Med 2-Pin (G9.5) PAR64 ExMogEndPr 2000 T10 12000 T26 R7S GX38 20000 T32 GX38 24000 T32 GX38 230 230 230 240 230 230 240 208 220 240 220 240 39739 37824 39738 CP77 10925 10929 10931 35338 P2/27 48771 48779 48772 48773 48774 48776 48777 GKV-Q575T6/4CL HPL750 FEP-Q1000T6/4CL EXC-Q1MPAR64CP60 EXD-Q1MPAR64CP61 EXE-Q1MPAR64CP62 FEX-Q2MT8/4CL Q12MT26/4CL 230V Q12MT264/CL 240V BCM Q20MT32/4CL BCM Q20MT32/4CL BCM Q20MT32/4CL Q24MT32/4CL 220V Q24MT32/4CL 240V 24 14000 3200 C-13 12 19750 3200 6C-8 24 25000 3200 CC-8 6 352000 3200 C-7A 6 297000 3200 C-7A 6 138000 3200 C-7A 12 50000 3200 CC-8 1 420000 3400 C-13 1 420000 3400 C-13 1 580000 3200 C-13 1 580000 3200 C-13 1 580000 3200 C-13 1 800000 3400 C-13 1 800000 3400 C-13 4.1 4.2 4.1 6 6 6 5.62 16.14 16.14 22.05 22.05 22.05 22.05 22.05 2.37 2.37 2.37 15722 15723 15724 15725 15558 15710 15714 15715 47868 47869 15712 15713 47857 47864 15716 15717 15718 15719 15720 15721 F15T8/CINEMA32 F15T8/CINEMA55 F17T8/CINEMA32 F17T8/CINEMA55 F20T12/CINEMA32 F20T12/CINEMA55 F30T12/CINEMA32 F30T12/CINEMA55 F32T8/CINEMA32 F32T8/CINEMA55 F20T12/CINEMA32/HO F20T12/CINEMA55/HO F40T12/CINEMA32 F40T12/CINEMA55 F40T12/CINEMA32/HO F40T12/CINEMA55/HO F72T12/CINEMA32/HO F72T12/CINEMA55/HO F96T12/CINEMA32/HO F96T12/CINEMA55/HO 24 720 24 700 24 800 24 770 24 780 24 760 24 1450 24 1400 36 1800 36 1750 24 1130 24 1100 30 2000 30 1950 30 2900 30 2820 15 4150 15 4050 15 5800 15 5650 3200 5500 3200 5500 3200 5500 3200 5500 3200 5500 3200 5500 3200 5500 3200 5500 3200 5500 3200 5500 18 18 24 24 24 24 36 36 48 48 24 24 48 48 48 48 72 72 96 96 8000 8000 20000 20000 10000 10000 18000 18000 20000 20000 7500 7500 20000 20000 15000 15000 15000 15000 15000 15000 3200 5500 3200 5500 3200 5500 3200 5500 3200 5500 3200 5500 18 18 24 24 24 24 36 36 48 48 24 24 8000 8000 20000 20000 10000 10000 18000 18000 20000 20000 7500 7500 20 22 38 10 10 13.94 13.94 13.94 13.94 13.94 17 20 20 12 14 24 9 10 11 CINEMA LAMPS FLUORESCENT LAMPS 15 T8 Medium BiPin (G13) 17 T8 Medium BiPin (G13) 20 T12 Medium BiPin (G13) 30 T12 Medium BiPin (G13) 32 T8 Medium BiPin (G13) 35 T12 Medium BiPin (G13) 40 T12 Medium BiPin (G13) 60 T12 Medium BiPin (G13) 85 T12 Medium BiPin (G13) 110 T12 Medium BiPin (G13) FLUORESCENT COVRGUARD® LAMPS 15 T8 Medium BiPin (G13) 17 T8 Medium BiPin (G13) 20 T12 Medium BiPin (G13) 30 T12 Medium BiPin (G13) 32 T8 Medium BiPin (G13) 35 T12 Medium BiPin (G13) 15800 15801 15806 15810 15766 15774 15779 15780 47881 47882 15775 15776 F15T8/CINEMA32/CVG 24 F15T8/CINEMA55/CVG 24 F17T8/CINEMA32/CVG 24 F17T8/CINEMA55/CVG 24 F20T12/CINEMA32/CVG 24 F20T12/CINEMA/55CVG 24 F30T12/CINEMA32/CVG 24 F30T12/CINEMA/55/CVG 24 F32T8/CINEMA32/CVG 36 F32T8/CINEMA55/CVG 36 F20T12/CINEMA32/HO/CVG24 F20T12/CINEMA55/HO/CVG24 720 700 800 770 780 760 1450 1400 1800 1750 1130 1100 For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose the one with the lowest watts. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering B 6-9 Stage and Studio Lamps Watts Shape Base Order LIF Volts Code Code Description Color Beam Spread Case Lumens Temp. Filament 10% 50% Qty. Initial CBCP K Design MOL LCL Horiz. Vert. Horiz. Vert. Rated Life Hours CINEMA LAMPS (CONTINUED) FLUORESCENT COVRGUARD® LAMPS (CONTINUED) 40 T12 Medium BiPin (G13) 60 T12 Medium BiPin (G13) 85 T12 Medium BiPin (G13) 110 T12 Medium BiPin (G13) 47876 47877 15782 15783 15785 15786 15794 15798 F40T12/CINEMA32/CVG 30 F40T12/CINEMA55/CVG 30 F40T12/CINEMA32/HO/CVG30 F40T12/CINEMA55/HO/CVG30 F72T12/CINEMA32/HO/CVG15 F72T12/CINEMA55/HO/CVG15 F96T12/CINEMA32/HO/CVG15 F96T12/CINEMA55/HO/CVG15 2000 1950 2900 2820 4150 4050 5800 5650 3200 5500 3200 5500 3200 5500 3200 5500 48 48 48 48 72 72 96 96 20000 20000 15000 15000 15000 15000 15000 15000 15816 15819 15811 15814 22084 22085 F36BX/CINEMA32 F36BX/CINEMA56 F55BX/CINEMA32 F55BX/CINEMA56 F55BX/CINPLUS/32 F55BX/CINPLUS/56 2900 2900 4100 4100 2400 2400 3200 5600 3200 5600 3200 5600 21.1 21.1 21.1 21.1 21.1 21.1 8000 8000 8000 8000 8000 8000 FLUORESCENT BIAX® 36 T5 2G11-4 Pin 55 T5 2G11-4 Pin 6-10 10 10 10 10 10 10 For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose the one with the lowest watts. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering B Footnotes Stage and Studio Lamps Bulb Watts OD GE Description Footnotes/ Stnd. Safety Product Pack Notices Code Qty. Base Initial Design Color Design Color CRI Volts Lumens Temp (K) Index Arc Rated CIE ColorLengthLife LCL x y (mm) (hrs) MOL (mm) Burn (mm) Position CSR METAL HALIDE LAMPS DISCHARGE-CSR/CSD (DAYLIGHT) METAL HALIDE, SINGLE-ENDED COLD START 250 T7 575 T9 700 T9 1200 T12 CSD250/2/SE CSR575/2/T/SE CSR575/2/SE CSR700/2/SE CSR1200/2/SE 14, 63 14, 63 14, 63 14, 63 14, 63 27817 49492 15378 49491 49490 10 10 10 10 6 GY9.5 GX9.5 GX9.5 G22 G22/30X53 90 97 97 70 100 18000 49000 49000 55000 110000 8500 7200 7200 7200 7200 65+ 80+ 80+ 80+ 85+ .289 .302 .302 .302 .302 .305 5 .320 7 .320 7 .320 8 .320 10 2000 1000 1000 1000 800 65 65 75 85 12 125 155 175 Any Any Any Any Any .330 .326 .320 .342 4 .330 7 .330 7 500 750 750 39 59 59 85 135 135 Any Any Any .328 4 .328 5 .328 6 .328 7 .328 11 .328 14 .328 20 .328 24 .328 28 .328 35 200 200 750 750 750 500 500 300 250 250 39 39 60 70 107 127 142 210 255 260 75 80 110 145 200 240 260 360 450 460 Any Any Any Any Any Any Any Any Any Any .325 8 .325 3 .325 7 .325 4 .325 7 .325 10 .325 14 .325 34 .325 24 .325 32 .325 45 .325 45 300 750 750 750 500 750 500 500 300 300 300 300 75 135 145 135 145 220 355 405 450 470 500 470 H15 Any Any Any H15 Any Any H15 H15 H15 H15 H15 .328 7 .327 7 .328 11 .328 14 .328 20 .328 24 750 1000 750 500 500 300 145 145 200 240 260 360 Any Any Any Any Any Any DISCHARGE-CSR (DAYLIGHT) METAL HALIDE, SINGLE-ENDED SHORT ARC 700 G7 1200 G9 1800 G9 CSR700/SA CSR1200/SA CSR2000/SA 14, 63 14, 18, 63 14, 18, 63 15380 21849 21801 6 6 4 GY9.5 GY22 GY22 70 100 100 58000 100000 155000 5600 5800 6000 75+ 80+ 80+ DISCHARGE-CSR (DAYLIGHT) METAL HALIDE, SINGLE-ENDED HOT RESTRIKE 125 200 400 575 1200 2500 4000 6000 12000 18000 T5 T6 T6 T9.5 T13 T19.5 T24 T26.5 T32 T32 CSR125/SE/HR 14, 63 CSR200/SE/HR 14, 63 CSR400/SE/HR 14, 18, 63 CSR575/SE/HR 14, 63 CSR1200/SE/HR 14, 63 CSR2500/SE/HR 14, 63 CSR4000/SE/HR 14, 63 CSR6000/SE/HR 14, 63 CSR12000/SE/HR 14, 63 CSR18000/SE/HR 14, 63 48461 48462 21853 48463 48464 48465 48466 48467 48468 22496 10 10 10 10 6 6 6 6 4 1 GZX9.5 GZY9.5 GZZ9.5 G22 G38 G38 G38 G38 G38 G51 80 70 70 95 100 100 200 130 160 225 9400 15000 32000 48000 110000 220000 380000 540000 1100000 1650000 5600 5600 6000 6000 6000 6000 6000 6000 6000 6000 90+ 90+ 90+ 90+ 90+ 90+ 90+ 90+ 90+ 90+ .323 .323 .323 .323 .323 .323 .323 .323 .323 .323 DISCHARGE-CSR (DAYLIGHT) METAL HALIDE, DOUBLE-ENDED HOT RESTRIKE 200 400 575 700 1200 2500 4000 6000 12000 18000 T4.5 T6.5 T6.5 T6.5 T6.5 T8.5 T9.5 T12 T16 T22.5 T28 CSR200/DE CSR400/S/DE CSR575/DE CSR700/S/DE CSR1200/S/DE CSR1200/DE CSR2500/DE CSR4000/DE CSR6000/DE CSR12000/DE CSR18000/DE CSR18000/S/DE 14, 63 14, 63 14, 63 14, 63 14, 63 14, 63 14, 63 14, 63 14, 63 14, 63 14, 63 14, 63 48450 22478 48451 22493 22494 48453 48454 48455 48456 48457 48459 48460 10 10 10 10 10 6 6 6 6 4 4 4 X515 SFc 10-4 SI/M4 SFc 10-4 SI/M4 SFc 10-4 SI/M4 SFc 10-4 SI/M4 SFc 15.5-6 SI/M6 Sfa21-12 Sfa21-12 25x51 Cyl 165mm 30x70 Cyl 165mm 30x70 Cyl 165mm 30x70 Cyl 165mm 80 49 95 70 100 100 115 200 125 160 225 225 16000 26000 49000 59000 110000 110000 240000 410000 570000 1100000 1650000 1650000 6000 7500 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 90+ 80+ 90+ 85+ 90+ 90+ 90+ 90+ 90+ 90+ 90+ 90+ .323 .323 .323 .323 .323 .323 .323 .323 .323 .323 .323 .323 CSR (DAYLIGHT) METAL HALIDE, SINGLE-ENDED HOT RESTRIKE UV-CONTROL 575 800 1200 2500 4000 6000 T9.5 T9.5 T13 T19.5 T24 T26.5 CSR575/SE/HR/UV-C CSR800/SE/HR/UV-C CSR1200/SE/HR/UV-C CSR2500/SE/HR/UV-C CSR4000/SE/HR/UV-C CSR6000/SE/HR/UV-C 14, 63 14, 63 14, 63 14, 63 14, 63 14, 63 40460 10 22495 10 27764 6 40482 6 27765 6 40492 6 G22 G22 G38 G38 G38 G38 95 95 100 100 200 130 48000 64000 110000 220000 380000 540000 5800 5800 5800 5800 5800 5800 90+ 90+ 90+ 90+ 90+ 90+ .323 .325 .323 .323 .323 .323 70 70 107 127 142 210 For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose the one with the lowest watts. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering B 6-11 Stage and Studio Lamps STAGE AND STUDIO ANSI CODES REFERENCE ANSI Order Code Code Lamp Description Volts ANSI Order Code Code Lamp Description Volts ANSI Order Code Code Lamp Description Volts ANSI Order Code Code Lamp Description Volts STAGE & STUDIO ANSI CODES STAGE & STUDIO ANSI CODES STAGE & STUDIO ANSI CODES STAGE & STUDIO ANSI CODES BCM BCM BCM BTL BTM BTN BTP BTR BVT BVV BVW BWA BWF BWM BWN CXZ CYV CYX DKX DKZ DPY DSE DTA DTY DWE DXW EGC EGE EGF EGG EGJ EGK EGM EGN EGR EGT EHC EHD EHF EHG EJD EJG EJG EKB EKD EMD EVR EXC EXC EXD EXD EXE EXE FAD FAY FBE FBO FBX FBY FCM FCM FCV FCW FCX FDB FDF FDF FDN FEL FEP FER FEV FEX FEY FFN FFP FFR FFS FFT FFT FGM FGN FGT FHM FKW FLK FLK FMR FRG FRK GFA GFB GFC GKV GLA GLC GLD GLE 48772 BCM Q20MT32/4CL 48773 BCM Q20MT32/4CL 48774 BCM Q20MT32/4CL 11966 BTL-Q500T6/CL/P 16465 BTM-Q500T64CL/2P 11953 BTN-Q750T7/CL/2P 11954 BTP-Q750T7/4CL2P 11955 BTR-Q1000T74CL2P 12554 BVT-Q1MT7/CL/MP 12553 BVV-Q1MT7/4CL/MP 12555 BVWQ2MT10/4CL/MP 39587 BWA-Q2000/4CL/BP 37086 BWF-Q2000/4CL 39680 BWM-Q750T7/4CLTP 39792 BWN-Q1000T7/4CL 37564 CXZ-Q1500T10/4CL 42697 CYVQ1000T7/4CLBP 36636 CYX-Q2000T10/4CL 40357 DKX/DSFQ1500PS52 39582 DKZ/DSE-Q1000PS5 41736 DPY-Q5000T20/4CL 34377 DSE/Q1000 30522 DTA-Q1500T8/4CL 18305 DTY-Q10M/T24/4CL 41667 DWE-Q650PAR36/1 ANSI Order Code Code Lamp Description 208 220 240 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 30157 DXW-Q1000T5/4CL 39134 EGC-Q500/5CL/P 39135 EGE-Q500CL/P 39136 EGF-Q750/4CL/P 39137 EGG-Q750CL/P 38853 EGJ-Q1000/4CL/P 38852 EGK-Q1000/4/P 39138 EGM-Q1000CL/P 30373 EGN-Q500T8 39190 EGR-Q750T7/4CL 39191 EGT-Q1000T7/4CL 39789 EHC-Q500/5CL 39768 EHD-Q500CL/TP 39771 EHF-Q750/4CL 39770 EHG-Q750CL/TP 23788 EJD-Q1000T3/3CL 20883 EJG/HIR-Q525T2 -1 23756 EJG-Q750T3/4CL 33934 EKB-Q420/4CL/2PP 34328 EKD-Q650/3CL/2PP 23755 EMD-Q750T3/4 47950 EVR-Q500CL/MC 93409 EXC-Q1MPAR64CP60 10925 EXC-Q1MPAR64CP60 10928 EXD-Q1MPAR64CP61 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 185 120 120 120 120 120 120 230 240 230 10929 EXD-Q1MPAR64CP61 10930 EXE-Q1MPAR64CP62 10931 EXE-Q1MPAR64CP62 30325 FAD-Q650T4/4CL 41668 FAY-Q650PAR36/3D 41669 FBE-Q650PAR36/5D 41671 FBO-Q650PAR36/5 30343 FBX-Q650T4/4 30374 FBY-Q1000T5/4 13895 FCM/HIR-Q650T3/4 23797 FCM-Q1000T3/4CL 35853 FCV-Q1000/4 41672 FCW-Q650PAR36/6 41673 FCX-Q650PAR36/7 23841 FDB-Q1500T4/4CL 20881 FDF/HIR-Q350T2/4 23735 FDF-Q500T3/4CL 23734 FDN-Q500T3/4 39769 FEL-Q1000/4CL 39738 FEP-Q1000T6/4CL 33760 FER-Q1000T6/4CL 14119 FEV-Q200/4CL/DC 35338 FEX-Q2MT8/4CL 39790 FEY-Q2000T8/4CL 13233 FFN-Q1000PAR64/1 240 230 240 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 230 120 120 230 120 120 13229 FFP-Q1000PAR64/2 13228 FFR-Q1000PAR64/5 13227 FFS-Q1000PAR64/6 20884 FFT/HIR-Q675T3/4 33280 FFT-Q1000T3/1CL 13226 FGM-Q1000PAR64/3 13225 FGN-Q1000PAR647D 41229 FGT-Q1500T4/4 23792 FHM-Q1000T3/4 39781 FKW-Q300T8 39730 FLK/LL-Q575T6 11450 FLK-Q575T6/4CL 30475 FMR-Q600T5 39623 FRG-Q500T8 39637 FRK-Q650T8 34812 GFA-Q1200PAR64/5 34810 GFB-Q1200PAR64/2 34808 GFC-Q1200PAR64/1 39739 GKV-Q575T6/4CL 93428 GLA-Q575T6/4CL 93429 GLC-Q575T6/5CL 92771 GLD-Q750T6/4CL 92773 GLE-Q750T6/4CL Volts STAGE & STUDIO ANSI CODES (SEE SECTION – HALOGEN) DVS EHM EHP EHR EHT EHZ ESL ESM ESN ESP ESR ESS ETB ETC ETD ETE ETF ETG ETH FCL 6-12 23733 Q500T3/CL-DVS 43703 Q300T3/CL-EHM 43705 Q300T4/CL-EHP 43708 Q400T4/CL-EHR 43699 Q250CL/MC-EHT 43704 Q300T3-EHZ 44383 Q150CL/MC/2V-ESL 43695 Q250MC-ESM 44385 Q100CL/MC/2V-ESN 44384 Q150CL/DC/2V-ESP 44386 Q100CL/DC/2V-ESR 43697 Q250CL/DC-ESS 43701 Q250DC-ETB 43693 Q150CL/DC-ETC 44657 Q100DC/2V-ETD 44656 Q100MC/2V-ETE 44653 Q150DC-ETF 43694 Q150CL/MC-ETG 44654 Q150MC-ETH 23731 Q500T3/CL-FCL 130 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose the one with the lowest watts. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering B 120 120 120 120 120 120 120 120 120 120 115 115 120 120 120 120 120 120 230 115 115 120 120 Stage and Studio Lamps FOOTNOTES # Footnote 1 2 3 4 5 6 7 8 9 10 11 Filament with low noise construction. Burn position horizontal ±4 degrees. Burn position base down to horizontal. Burning position vertical base down ±45 degrees. Burning position horizontal ±15 degrees. Enclosed fixture only per UL standard 1572. In accordance to Federal Regulations (21CFR 1040.30) the following notice applies. WARNING: This lamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation if the outer envelope of the lamp is broken or puntured, and the arc tube continues to operate. Do not use where people will remain more than a few minutes unless adequate shielding or other safety precautions are used. Certain types of lamp that will automatically extinguish when the outer envelope is broken or puntured are commercially available. Frosted. Apparent lighted length slightly longer than similar clear lamp. Life dependent on service conditions; for use only in equipment specially designed to maintain bulb and base temperatures within safe limits. Available late 2003. To avoid possible overheating, this lamp is not recommended for use without force-cooling in deep-bowled fixtures. Burn vertical base down ± 30 degrees. 12 Safety Notice for exposed unshielded lamps (if shielded fixture use footnote 13) WARNING Risk of electrical shock • Turn power off before inspection,installation or removal Risk of fire • Keep combustible materials away from lamp • Use in enclosed fixture rated for this product Pressurized lamp-unexpected rupture may cause injury, fire, or property damage • Use eye protection when handling lamp • Do not touch glass with bare hands • Use in enclosed fixtures rated for this product • Do not use lamp if outer glass is scratched or broken • Operate lamp only in specified position • Do not exceed 110% of rated voltage CAUTION Risk of burn • Allow lamp/fixture to cool before handling • Turn power off before installing lamp Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Wear safety glasses and gloves when handling lamp Lamp emits UV ratiation which may cause eye/skin irritation. RG-2. • Limit unshielded exposure to less than 15 minutes per day 13 Safety Notice for PAR lamps and enclosed, shielded lamps WARNING Risk of electrical shock • Turn power off before inspection, installation or removal Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass is broken. Remove and dispose of lamp Pressurized lamp-unexpected rupture may cause injury, fire, or property damage • Use in enclosed fixtures rated for this product • Do not use lamp if outer glass is scratched or broken • Do not exceed 110% of rated voltage • Avoid direct water/liquid contact CAUTION Risk of burn • Allow lamp/fixture to cool before handling • Turn power off before installing lamp Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose the one with the lowest watts. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering B 6-13 Stage and Studio Lamps NOTES \ 6-14 For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose the one with the lowest watts. All footnote references found at the end of this section. Reduced Wattage ✐ High Color Rendering B Miniature & Sealed Beam Lamps GENERAL INFORMATION Lamp Locator - Miniature .................................................................................................. 7-2 Miniature Bases...................................................................................................................... 7-3 Sealed Beam Lamps and Bases ..................................................................................... 7-3 Introduction, Abbreviations .............................................................................................. 7-4 LAMPS Miniature Lamps .................................................................................................................... 7-5 Sealed Beam Lamps ..........................................................................................................7-16 FOOTNOTES AND SAFETY NOTES ......................................7-21 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. 7-1 Miniature & Sealed Beam Lamps LAMP LOCATOR The lamps listed here are not to scale. To determine the diameter of a bulb in inches, multiply the bulb number by one-eighth. For example T-2 means approximately 2⁄8" or 1⁄4" diameter. B-3 1⁄2 G-3 1⁄2 B-6 R-12 T-1 3⁄4 G-5 RP-11 T-2 1⁄4 T-2 G-6 S-8 T-2 1⁄2 T-2 3⁄4 S-11 TL2 3⁄4 T-3 1⁄4 TL-3 T-4 1⁄2 T-4 Electric Discharge 7-2 G-4 1⁄2 T-3 TL-3 1⁄4 T-4 3⁄4 Central Discharge T-5 Neon Glow T-1 T-3 1⁄2 T-7 Festoon Type For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. T-8 Miniature & Sealed Beam Lamps MINIATURE BASES Bases provide electrical contact to the lamp and, in most cases, also support the lamp in the fixture. For miniature and subminiature lamps, bayonet or wedge base types are generally preferred over screw types when vibration BiPin M-23 Candelabra Screw S.C. Bayonet S.C. Midget Flanged D.C. Bayonet S.C. Miniature Flanged D.C. Indexing D.C. Prefocus S.C. Prefocus Sub-Midget Flanged is present. In addition, wedge bases reduce socket size and complexity. Flanged or collared types are usually associated with requirements for filament location. Midget Screw Tel. Slide No. 3 Midget Grooved Tel. Slide No. 5 Miniature Bayonet Miniature Cap Wire Terminal (Up Position) Wedge Miniature Screw Rigid Loop Wedge Extended Leads S.C. AND D.C. PREFOCUSED BASE LAMPS The letter “A” following the base type designates that the distance from the bottom of the collar to the bottom of the base contact is 13⁄32". For “B” bases this distance is 9⁄16". The few lamps identified by the letter “S” in the “Base” column are special in that the collar location and/or the orientation of the contacts differs from the above. SEALED BEAM LAMPS 203 mm 8" 178 mm 7" 146 mm 5 3/4 " 114 mm 4 1/2" Welded PAR36 PAR46 PAR56 PAR64 200 mm 165 mm 100 mm 92 mm 64 mm 142 mm 150 mm 140 mm 140 mm 150 mm 165 mm 200 mm Halogen Inner Lamp Sealed Beam SEALED BEAM BASES Bases provide electrical contact to the lamp. The most common bases for sealed beam lamps are the screw terminal and contact lug types. Other types are also available, as illustrated. 2 Lugs 2 Contact Lugs Screw Terminals Slip-on Terminals Combination 2 Right Angled Lugs 3 Contact Lugs 3 Screw Terminals 3 Slip-on Terminals 3 Contact Angled For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. Right Angled Plastic 7-3 Miniature & Sealed Beam Lamps INTRODUCTION D.C. Double Contact PAR ECE European Common Market Pf. (European Motor SAE Vehicle Standards) Flg. Flanged Sc. HID High Intensity Discharge S.C. HIR Halogen Infrared Spec. LCL Light Center Length Tel. Min. Miniature Term. MOL Maximum Overall Length V MSCP Mean Spherical Candlepower W Nom. Nominal GE MINIATURE AND SEALED BEAM PRODUCT ORDERING INFORMATION GE Miniature and Sealed Beam Lamps are designed for those applications requiring specific bulb size, base, and voltage. These lamps are operated on vehicles (cars, trucks, boats, aircraft, tractors) or in special applications utilizing low voltage sources. Most lamps are designated by common ANSI (American National Standards Institute) lamp numbers and lamps in this section are arranged in numerical order. To assist you in identifying lamps, drawings (not to scale) are provided, along with descriptions of bulb and base sizes. Specific market segments covered in this section are products used in: Aircraft Emergency Building Lighting Marine Automotive Flashlight/Hand Lanterns Medical/Instruments Agriculture Garden/Outdoor Telephone CIM/Tractor Indicator Toys/Entertainment For additional specifications refer to Miniature and Sealed Beam Catalog obtained through your GE Sales Office. Automotive Selection Guide also available. GE MINIATURE LAMP PREFIXES DE H K PC PR Double-Ended Q Quartz Halogen Halogen SE Single-Ended Krypton Gas W,T,R,C,P European Designation Printed Circuit Application Prefocus Base (E.G., “Flashlight Lamp”) GE MINIATURE LAMP SUFFIXES FINDING AND ORDERING A LAMP A Amber NA Natural Amber AF All Frost (on outside) (automotive lighting) AS10 Ages and Selected PSB Pilot Indicator/Short Base (for candlepower) R Red B Blue SB Silver Bowl (all or some portion C1 Refers to a range of current of bulb is silver) on telephone lamps (A1, TY Letters after a quartz halogen B1, D1, E1, etc. used also) lamp mean a deviation from the CW Cool White (aircraft lighting) standard lamp - usually refers to D Lead Wires Down the electrical terminals E Extended Lead Wires U Lead wires up or no base, e.g., E-1 Different lead wire unbased sealed beam lamp material (NI plated) WW Warm White (aircraft lighting) G Green X Indicates some arbitrary deviation HD Heavy Duty from the normal product HIR Halogen Infrared Y Yellow HO High Output -1 Slip on terminals K Unique Base -2 Represents various deviations KR Krypton Fill -3 Represents deviations L, XL, LL Long Life (e.g. combination terminal) MB Miniature Bayonet W European Designation (Watts) Most Miniature Lamps have a number on the base or bulb. Generally it will match the lamp number in this catalog, which is sorted in numeric order (prefixes last). The catalog is divided into Miniature and Sealed Beam sections. Sealed Beam lamps start on page 7-16. Often the first prefix is another lamp manufacturer’s identification and can be ignored. You can verify the lamp using the drawings provided. Order codes for Blister, Unit, and Bulk Pack for OEM’s are provided. FORMULAS The following are commonly used formulas to assist any calculations you may need. For further information, contact your GE Lamp Representative. • Watts = Volts x Amps • Lumens = 12.57 x Mean Spherical Candlepower • Kelvin = Celsius + 273 • Footcandles = Candlepower/Distance squared • Hot Resistance (Ohms) = Volts/Amps (miniature lamps only) ABBREVIATIONS The abbreviations used in this catalog include: A Amperes ANSI American National Standards Institute Bay. Bayonet C.I.M. Construction & Industrial Machinery C.P. Candlepower Cand. Candelabra MSCP/MBCP Primary Application: Current uses of the lamp in general. Lamps are used in other applications than listed. Approximate output expressed as initial mean spherical candlepower (see lumen conversion). For sealed beam MBCP is the maximum intensity of the beam in candelas, generally in the beam’s center, and spread is beam size expressed in degrees. GE Lamp No.: In nearly all cases lamps are marked with a General Electric Trade Number recorded with the ANSI. See glossary of prefixes and suffixes above. Case Qty. Order Code: Quantity of lamps per Use this code when ordering case if blister pack (BP), to ensure that you receive the unit, or bulk (OEM’s).* exact product you require. Blister Order Code Case Qty. GE Unit Bulk BP/Unit/Bulk Lamp No. Parabolic Aluminized Reflector Prefocus Society of Automotive Engineers (US Motor Vehicle Standards) Screw Single Contact Special Telephone Terminals Volts Watts Filament Design Bulb: Energy used expressed as amperes (A) or watts (W) at design voltage. The prefix letter describes the shape and the number is the approximate bulb diameter. Volts: Base: Voltage at which the lamp is designed to provide the amperes, candlepower, and laboratory life characteristics. Base types are depicted on the previous pages for both Miniature and Sealed Beam. Volts Amps or Watts MSCP Bulb In inches from the top of the bulb to the bottom of the base. Rated Life Amps or Watts Primary Application MOL: C=coiled, CC=coiled coil, -6=horizontal, -8=vertical to base. See Miniature and Sealed Beam Catalog for all variations. Base Lamp burning hours to medium life expectancy. LCL Distance in inches between base reference plane and filament center. Filament Design LCL (in) C-6 1.25 Safety Footnotes See page 7-21 for explanation. MOL Rated Life Warning (in) (hrs) & Footnotes MINIATURE LAMPS 40848 14132 /10/540 862 Tractor 12.8 2.93A 60 T-31⁄4 Rt Angle Prefocus 2 T-2 is Tubular approximately ⁄8" in diameter. Sealed Beam bulb sizes are also in eighths of an inch if round (PAR). PAR36 is 36⁄8" or 4 1⁄2" in diameter. If the Sealed Beam is rectangular in shape the longest side is measured in millimeters. A 165mm Sealed Beam measures 6 1⁄2" (165mm) across the top. * Miniature Incandescent BP is 2 lamps, Miniature Halogen BP is 1 lamp, selected miniature headlamps available in 2 pack BP; PC not shown. 7-4 T 31⁄4 Identifies the shape (S=Pear, T=Tubular, G=Globe, R=Reflector) Identifies the approximate bulb diameter in eighths of an inch. For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. 2.68 1,900 306 Miniature & Sealed Beam Lamps Blister Order Code Case Qty. GE Unit Bulk BP/Unit/Bulk Lamp No. Primary Application Volts Amps or Watts MSCP Bulb Base Filament Design LCL (in) C-6 C-6 C-2R C-2R C-6 C-6 C-2V C-2V C-2R C-2F C-2R C-2R C-2R C-2R C-2V C-2R C-2V C-2R C-2R C-2R C-2R C-2F C-2F C-2F C-2R C-2R C-2F C-2F C-6 C-2R C-2R C-2R C-6 C-6 C-2V C-2V C-6 S-2 C-2R C-2R C-2R C-2V C-2F C-2F C-2F C-2F C-2F C-2F C-2F C-2F C-2F .62 .62 .72 .72 .69 .62 .46 .46 .72 .40 .78 .78 .78 .50 .50 .56 .56 .75 .75 .81 .81 .40 .40 .40 .75 .75 .40 .40 1.12 .75 .75 .75 1.12 1.12 .81 .75 1.06 – .56 .56 1.0 .56 .56 .56 .56 .56 .56 – .56 – – MOL Rated Life Warning (in) (hrs) & Footnotes MINIATURE LAMPS 25312 25319 25331 25354 25371 25377 25379 12325 17853 12316 25388 26480 39220 13689 25442 25450 25485 25529 25550 25552 25576 23218 25591 12321 25643 12324 25652 25654 25692 43606 43607 23015 39218 39219 21029 38457 38458 25736 25751 40969 40967 40968 25772 12363 25778 18618 47797 12364 25794 25796 23217 25811 25813 25829 25831 12322 25836 25838 16287 16286 36147 25848 25916 15731 25927 25931 25933 23016 25956 16489 12327 25962 16302 47827 19553 19852 19921 11807 12328 25965 16303 12356 12357 /50/ /50/ /50/ /50/ /50/ /50/1000 48/50/ 48/ / /50/ 48/50/4000 /50/ /50/ /50/ /50/ /50/4000 /50/ 48/50/ 48/ / /50/ 48/50/1000 /50/ /50/4000 48/50/4000 48/50/4000 /50/ /50/ /50/ /50/4000 /10/ 48/50/1000 48/ / 48/50/1000 48/50/500 /50/500 48/50/1000 /50/1000 /50/ /50/ /50/ / /1000 /50/ /50/4000 48/50/4000 48/50/4000 48/ / /50/4000 / /4000 / /4000 48/50/4000 48/ / 48/ / 10 12 13 14 15 19 24 24NA 27 37 43 44 47 51 53 55 57 63 64 67 68 70 73 74 81 82 85 86 88 89 89KR 90 93 94 97 98 105 112 147 149 157 158 161 168 168XL 193 193E 193E-1 194 194B 194G Indicator Radio Flashlight – 3D Cells Flashlight – 2D Cells Indicator Toy Train Auto Side Marker Auto Side Marker Hand Lantern – 4F Cells Auto Indicator Indicator, Radio, and TV Radio, TV, and Indicator Indicator Auto and Indicator Instrument Auto and Instrument Coin Machine Aircraft and Marine Auto Auto and Marine Auto Indicator Auto Auto, Aircraft Auto and Marine Indicator Indicator Indicator Auto Auto. Krypton. Long Life Auto and Marine Auto Auto and Marine Auto – Heavy Duty Auto, Heavy Duty Auto Interior – Heavy Duty Flashlight – 1AA, C or D Indicator Emergency Lighting Medical Auto, Instrument Auto, Instrument Auto Instrument Auto-Long Life Heavy Duty Truck Heavy Duty Truck Truck Clearance Auto, Instrument Auto courtesy – Blue Auto courtesy – Green 2.50 6.30 3.70 2.47 7.0 14.4 14.0 14.0 4.9 14.0 2.5 6.3 6.3 7.50 14.4 7.0 14.0 7.0 7.0 13.5 13.5 14.0 14.0 14.0 6.5 6.5 28.0 6.3 6.8 13.0 13.0 13.0 12.8 12.8 13.5 13.0 12.8 1.2 7.0 6.15 5.8 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 .50A .15A .30A .30A .40A .10A .24A .24A .30A .09A .50A .25A .15A .22A .12A .41A .24A .63A .63A .59A .59A .15A .08A .10A 1.02A 1.02A .04A .20A 1.91A .58A .58A .58A 1.04A 1.04A .69A .62A 1.00A .22A .43A .53A 1.10A .24A .19A .35A .35A .33A .33A .33A .27A .27A .27A .5 .35 .98 .5 2 .9 2 1.5 1.4 .5 .5 .9 .52 1 1 2 2 3 3 4 4 1.5 .3 .7 6 6 .3 .4 15 6 6 6 15 15 4 6 12 – 2 3.5 8.1 2 1 3 3 2 2 2 2 2 2 G-31⁄2 G-31⁄2 G-31⁄2 G-31⁄2 G-41⁄2 G-31⁄2 T-23⁄4 T-23⁄4 G-41⁄2 T-13⁄4 T-31⁄4 T-31⁄4 T-31⁄4 G-31⁄2 G-31⁄2 G-41⁄2 G-41⁄2 G-6 G-6 G-6 G-6 T-13⁄4 T-13⁄4 T-13⁄4 G-6 G-6 T-13⁄4 T-13⁄4 S-8 G-6 G-6 G-6 S-8 S-8 G-6 G-6 B-6 TL-3 T-31⁄4 T-31⁄4 G-6 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 Miniature Two Pin Miniature Two Pin Miniature Screw Miniature Screw Miniature Two Pin Miniature Two Pin Wedge Wedge Miniature Screw Wedge Miniature Bayonet Miniature Bayonet Miniature Bayonet Miniature Bayonet Miniature Bayonet Miniature Bayonet Miniature Bayonet S.C. Bayonet D.C. Bayonet S.C. Bayonet D.C. Bayonet Wedge Wedge Wedge S.C. Bayonet D.C. Bayonet Wedge Wedge D.C. Bayonet S.C. Bayonet S.C. Bayonet D.C. Bayonet S.C. Bayonet D.C. Bayonet S.C. Bayonet S.C. Bayonet S.C. Bayonet Miniature Screw Wedge Wedge Miniature Screw Wedge Wedge Wedge Wedge Wedge Wire Terminal Wire Terminal Wedge Wedge Wedge For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. .94 .94 .94 .94 1.07 .94 .91 .91 1.07 .80 1.19 1.19 1.19 .94 .94 1.07 1.07 1.44 1.44 1.44 1.44 .80 .80 .80 1.44 1.44 .80 .80 2.0 1.44 1.44 1.44 2.0 2.0 1.44 1.44 1.75 .93 1.06 1.06 1.22 1.06 1.06 1.06 1.06 1.06 1.06 1.06 1.06 1.06 1.06 3,000 5,000 15 15 500 1,000 1,500 1,500 30 2,500 3,000 3,000 3,000 1,000 1,000 500 500 1,000 1,000 5,000 5,000 100 15,000 1,000 500 500 7,000 20,000 300 750 1,500 750 700 700 5,000 800 500 5 1,500 15 50 500 4,000 1,500 3,000 15,000 15,000 15,000 2,500 2,500 2,500 69 44, 69 116 116 69 69 116 4 4 14 79 79 79, 130 4 116 127 122 122 132 132 7-5 Miniature & Sealed Beam Lamps Blister Order Code Case Qty. GE Unit Bulk BP/Unit/Bulk Lamp No. Primary Application Volts Amps or Watts MSCP Bulb Filament Design LCL (in) Wedge Wedge Wedge Wedge D.C. Index C-2F C-2F C-2F C-2F C-6 – – – .56 1.25 1.06 1.06 1.06 1.06 2.0 S.C. Bayonet D.C. Bayonet Miniature Cap Miniature Cap Miniature Cap Miniature Screw Miniature Screw Miniature Screw Wedge Miniature Bayonet Miniature Bayonet Miniature Bayonet S.C. Bayonet D.C. Bayonet S.C. Bayonet D.C. Bayonet S.C. Bayonet S.C. Bayonet D.C. Bayonet S.C. Bayonet S.C. Bayonet D.C. Bayonet D.C. Bayonet S.C. Bayonet S.C. Bayonet Miniature Bayonet S.C. Bayonet Miniature Bayonet G4 2-Pin S.C. Midget Flanged S.C. Midget Flanged S.C. Midget Flanged Midget Grooved Midget Flanged Midget Flanged Miniature Bayonet Midget Flanged S.C. Midget Flanged S.C. Midget Flanged S.C. Midget Flanged Midget Flanged Midget Grooved Midget Flanged Midget Grooved Midget Flanged Wedge C-6 C-6 C-8 C-8 C-8 C-2R C-2R C-2R C-2R C-2F C-2R C-2F C-2F C-2F C-2F C-2F C-2V C-2V C-2V C-2V C-2V C-2V C-2V C-2V C-2V C-2F C-2V C-2R C-2R C-2F C-2R C-2F C-2F C-2R C-2R C-2F C-2V C-2F C-2F C-2F C-2F C-2F C-2F C-2F C-2F C-2F 1.25 1.06 – – – – – .81 .65 .50 .62 .56 .69 .69 .75 .75 1.12 – 1.12 1.12 – 1.12 – 1.25 1.25 .62 1.12 .62 .78 .38 .38 .38 .38 2.0 1.75 1.72 1.72 1.72 .93 .93 1.07 1.06 .94 1.19 1.07 1.25 1.25 1.44 1.44 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.38 2.38 1.19 2.0 1.19 1.16 .63 .63 .63 .63 .63 .63 .94 .64 .63 .63 .81 .36 .63 .63 .63 .64 1.06 Base MOL Rated Life Warning (in) (hrs) & Footnotes MINIATURE LAMPS (CONTINUED) 12319 44859 27470 48/50/4000 194NA Auto Sidemarker. Amber 47794 48/ / 194NAXL Auto Sidemarker. Amber 12355 48/ / 194R Auto courtesy – Red 25832 48/ / 194XL Auto, Long Life 37983 37984 /50/500 198 Truck Stop, Signal 14.0 14.0 14.0 14.0 12.8 14.0 37985 37986 /50/500 199 Truck Signal 12.8 25988 /50/ 210 Instrument 6.5 12673 39224 39225 48/50/1000 211-2 Auto 12.8 23220 39223 48/ /1000 212-2 Auto 13.5 39356 39357 /50/1000 214-2 Auto 13.5 26008 /50/ 222 Flashlight – AA cells 2.25 26063 /50/ 243 Flashlight – 2 C cells 2.33 26095 /50/ 258 Toy Train, Flasher Lamp 14.0 26099 /50/ 259 Radio, TV, and Indicator 6.3 44719 /50/ 265 Indicator 28.0 42758 /50/ 267 Indicator – Flasher Lamp 6.3 32688 /50/ 293 Auto and Radio 14.0 81642 /50/ 301 Aircraft 28.0 26120 /50/ 302 Aircraft 28.0 81641 /50/ 303 Aircraft 28.0 81643 /50/ 304 Aircraft 28.0 26143 /50/ 305 Aircraft 28.0 26145 /50/ 305AF Aircraft – All frosted 28.0 26152 /50/ 306 Aircraft 28.0 81644 /50/ 307 Aircraft 28.0 26161 /50/ 307AF Aircraft – All frosted 28.0 81645 /50/ 308 Aircraft 28.0 81646 /50/ 308AF Aircraft – All frosted 28.0 26175 /10/ 309 Aircraft 28.0 81647 /10/ 311 Aircraft 28.0 81649 81650 /50/4000 313 Aircraft 28.0 81651 /50/ 315 Aircraft 28.0 81652 /50/ 316 Aircraft 6.0 80862 /10/ 317 Aircraft 12.0 28519 /50/ 327 Aircraft 28.0 28546 /50/ 328 Aircraft 6.0 28567 /50/ 330 Aircraft 14.0 28588 /50/ 334 Aircraft 28.0 29917 / /1000 338 Aircraft 2.7 29918 / /1000 345 Aircraft 6 26255 /50/ 356 Aircraft 28.0 87381 / /1000 380 Aircraft 6.3 28653 /50/ 381 Indicator 6.3 28657 /50/ 382 Indicator 14.0 28660 /50/ 385 Indicator 28.0 87306 / /1000 385AS15 Aircraft 28.0 28662 /50/ 386 Indicator 14.0 28664 25090 /50/1000 387 Indicator 28.0 28672 /50/ 388 Indicator 28.0 87398 / /1000 394 Aircraft 12 38918 /50/ 400 Aircraft 28.0 7-6 .27A 1.5 T-31⁄4 .27A 1.5 T-31⁄4 .27A 2 T-31⁄4 .27A 2 T-31⁄4 2.25A 32 S-8 .59A 3 2.25A 32 S-8 1.78A 15 B-6 .97A 12 T-3 .74A 6 T-3 .52A 4 T-3 .25A – TL-3 .27A – TL-3 .27A 1.6 G-41⁄2 .25A .65 T-31⁄4 .08A .75 G-31⁄2 .15A .33 T-31⁄4 .33A 2 G-41⁄2 .17A 3 G-5 .17A 3 G-5 .30A 6 G-6 .30A 6 G-6 .51A 15 S-8 .51A – S-8 .51A 15 S-8 .67A 21 S-8 .67A 21 S-8 .67A 21 S-8 .67A – S-8 .90A 32 S-11 1.29A 50 S-11 .17A 3.5 T-31⁄4 .90A 32 S-8 .70A 3.4 T-31⁄4 3.5W 2.63 T-3 .04A .34 T-13⁄4 .20A .34 T-13⁄4 .08A .5 T-13⁄4 .04A .34 T-13⁄4 .06A .04 T-13⁄4 .04A .055 T-13⁄4 .17A 3.5 G-31⁄2 .04A .03 T-13⁄4 .20A .4 T-13⁄4 .08A .3 T-13⁄4 .04A .15 T-13⁄4 .04A .2 T-13⁄4 .08A .3 T-13⁄4 .04A .3 T-13⁄4 .04A .3 T-13⁄4 .04A .12 T-13⁄4 .10A 1.6 T-31⁄4 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. .50 .38 .38 .44 .38 .38 .56 2,500 5,000 2,500 12,000 1,200 5,000 1,200 100 1,000 2,000 1,000 5 10 500 5,000 5,000 5,000 7,500 500 500 500 500 300 300 300 300 300 300 300 300 300 500 300 500 1000 4,000 1,000 1,500 4,000 6,000 10,000 500 50,000 20,000 40,000 10,000 25,000 40,000 7,000 7,000 10,000 1,000 132 110, 147 110 4 4 116 116 3, 70 44, 147 3, 70 79 10 79 14 79 79 78,79 79 79 Miniature & Sealed Beam Lamps Blister Order Code Case Qty. GE Unit Bulk BP/Unit/Bulk Lamp No. Primary Application Volts Amps or Watts MSCP Bulb Base Filament Design LCL (in) C-2R C-2F C-2F C-2R C-2R C-2R C-2V C-8 C-8 C-8 C-8 C-8 C-2V C-2V C-2R 2C-2V 2C-2V 2C-2R C-2F C-2F C-2F C-2R C-2R C-2R C-2R C-2R CC-6 C-2R C-2R C-2R C-2R C-2R C-2R C-2F C-2F C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 .72 .56 .56 .72 .75 .65 – – – – – – .5 .5 .72 .75 .75 .75 .56 .56 0.56 MOL Rated Life Warning (in) (hrs) & Footnotes MINIATURE LAMPS (CONTINUED) 26354 /50/ 26441 /50/ 39645 /50/ 26460 /50/ 26485 /50/ 44773 44774 /50/4000 38269 /50/ 12358 39746 40023 48/50/1000 23019 40024 48/ /1000 26205 48/ / 12672 48/ / 23020 48/ / 18442 18439 /50/4000 25199 25200 /50/4000 26549 /50/ 81653 81654 /50/1000 26567 26568 /50/1000 23023 26570 48/50/ 38866 /50/ 38196 /50/ 81670 /50/ 87407 / /1000 87336 / /1000 87321 / /1000 28706 / /1000 87276 /1000 43132 /50/ 87411 / /1000 29903 / /1000 29901 / /1000 29916 / /1000 29905 / /1000 26591 /50/ 26593 /50/ 81655 /50/ 11014 /20/ 11250 /10/ 12723 12724 /10/500 47618 / /500 49718 /10/ 18344 18345 /10/500 44840 44841 /10/500 44500 44501 /10/500 43760 43761 /10/500 43762 43763 /10/500 43764 43765 /10/500 43115 43116 /10/500 43117 43118 /10/500 43119 /10/ 43121 43122 /10/500 43123 43124 /10/500 20469 /10/ 425 456 464 502 509K 555 558 561 562 563 570 577 590 591 605 623 624 631 656 657 658 680 683 683AS15 685 685AS15 705 713 715 715AS15 718 718AS15 755 756 757 767 773 774 777 778 780 782 783 784 785 786 787 788 789 790 791 795 Hand Lantern – 4F Cells Instrument Aircraft Hand Lantern – 4F Cells Indicator Coin, Novelty Auto Lens end Auto Auto Auto Truck Bed Light Auto Strip Lighting (Xenon) Strip Lighting (Xenon) Flashlight – 5D Cells Instrument Marine Auto Indicator Indicator Indicator Aircraft Aircraft Aircraft Aircraft Aircraft Aircraft Aircraft Aircraft Aircraft Aircraft Aircraft Indicator Indicator Indicator Instrument Special Service Emergency Lighting Flashlight, Halogen Instrument Strip Light Special Service Emergency Lighting Emergency Lighting Emergency Lighting Emergency Lighting Instrument Instrument Instrument Instrument Instrument Signal 5.0 28.0 28.0 5.1 24.0 6.3 13.0 12.8 13.5 13.5 12.8 12.8 13.5 14.0 6.15 28.0 28.0 14.0 28.0 28.0 14.0 5.0 5.0 5.0 5.0 5.0 28.0 5.0 5.0 5.0 5.0 5.0 6.3 14.0 28.0 6.0 12.0 12.0 4.0 6.0 12.0 12.0 12.0 6.0 6.0 6.0 6.0 6.0 12.0 14.0 14.0 12.8 .50A 2.3 G-41⁄2 .17A 2 G-41⁄2 .17A 3 T-31⁄4 .15A .6 G-41⁄2 .18A 2.8 G-6 .25A .9 T-31⁄4 .33A – TL-31⁄4 .97A 12 T-3 .74A 6 T-3 .52A 4 T-3 2.10A 32 T-43⁄4 1.40A 21 T-43⁄4 .37A 4 T-31⁄4 .24A 2 T-31⁄4 .50A 3.4 G-41⁄2 .37A 6 G-6 .37A 6 G-6 .63A 6 G-6 .06A .62 T-31⁄4 .08A .62 T-31⁄4 .08A 0.31 T-31⁄4 .06A .03 T-1 .06A .05 T-1 .06A .05 T-1 .06A .05 T-1 .06A .05 T-1 .51A 15 S-8 .75A .09 T-1 .115A .15 T-1 .115A .15 T-1 .115A .15 T-1 .115A .15 T-1 .15A .33 T-31⁄4 .08A .31 T-31⁄4 .08A .62 T-31⁄4 2.00A 19 T-21⁄4 .67A 10 T-23⁄4 .67A 13 T-21⁄4 1.20A 5.5 T-21⁄4 3.33A 32 T-23⁄4 10W 12 T-23⁄4 1.66A 25 T-23⁄4 1.00A 22 T-21⁄4 1.00A 9 T-21⁄4 1.33A 13 T-21⁄4 2.00A 19 T-21⁄4 1.67A 16 T-21⁄4 3.33A 32 T-21⁄4 1.17A 22 T-23⁄4 1.79A 42 T-23⁄4 2.50A 61 T-23⁄4 50W 108 T-4 Miniature Screw Miniature Bayonet Wedge Miniature Screw Candelabra Screw Wedge Wedge Rigid Loop Rigid Loop Rigid Loop Rigid Loop Double End Cap Wedge Wedge Miniature Screw S.C. Bayonet D.C. Bayonet S.C. Bayonet Wedge Wedge Wedge Wire Terminal Wire Terminal Wire Terminal Sub-Midget Flanged Sub-Midget Flanged S.C. Bayonet Wire Terminal Wire Terminal Wire Terminal Sub-Midget Flanged Sub-Midget Flanged Miniature Bayonet Miniature Bayonet Miniature Bayonet Miniature Bayonet G-4 Two Pin G-4 Two Pin G-4 Two Pin G-4 Two Pin G-4 Two Pin G-4 Two Pin G-4 Two Pin G-4 Two Pin G-4 Two Pin G-4 Two Pin G-4 Two Pin G-4 Two Pin G-4 Two Pin G-4 Two Pin G-4 Two Pin S.C. Bayonet For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. .19 1.12 .78 .62 .62 .56 .77 .77 .77 .77 .77 .77 .77 .77 .77 .77 .77 .77 .77 .77 .77 1.25 1.07 15 1.07 5,000 1.06 1,500 1.07 100 1.47 1,000 1.06 3,000 1.06 500 1.72 1,000 1.72 2,000 1.72 1,000 1.72 600 1.72 1,000 1.06 2,000 1.06 3,000 1.07 15 1.44 1,000 1.44 1,000 1.44 1,000 1.06 2,500 1.06 15,000 1.06 15,000 .24 100,000 .24 100,000 .24 100,000 .38 40,000 .36 100,000 2.0 900 .24 100,000 .25 40,000 .25 40,000 .36 40,000 .36 40,000 1.19 20,000 1.19 15,000 1.19 15,000 1.13 50 1.05 1,000 1.0 50 1.0 275 1.05 100 1.05 2,000 1.05 2,000 1.0 50 1.0 50 1.0 50 1.0 50 1.0 100 1.0 100 1.05 200 1.05 200 1.05 200 2.50 200 116 116 303 68 4 4 116 79 79 79 306 124, 306 124, 306 124, 306 124, 306 124, 306 124, 306 124, 306 124, 306 124, 306 124, 306 124, 306 124, 306 124, 306 124, 306 124, 306 4, 306 7-7 Miniature & Sealed Beam Lamps Blister Order Code Case Qty. GE Unit Bulk BP/Unit/Bulk Lamp No. Primary Application Volts Amps or Watts MSCP Bulb Base Filament Design LCL (in) MOL Rated Life Warning (in) (hrs) & Footnotes C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 1.25 1.25 2.68 1,900 306 2.68 300 17, 160, 306 150 2.68 300 17, 160, 306 2.68 1,000 17, 160, 306 2.68 300 17, 160, 306 150 2.68 1,000 17, 160, 306 2.68 300 17, 160, 306 1.18 2,000 306 1.0 2,000 124, 306 2.68 200 4, 306 2.68 200 4, 306 2.68 400 4, 306 2.68 400 4, 306 2.68 300 306 2.68 300 306 1.0 500 306,124 2.68 300 306 2.68 200 4, 17, 160, 306 2.68 200 4, 17, 160, 306 2.68 200 4, 306 2.68 200 4, 306 2.68 200 4, 17, 160, 306 2.68 1,900 4, 17, 160, 306 2.68 1,900 4, 17, 160, 306 1.49 500 1.49 500 1.49 5,000 4 1.49 1,000 1.49 1,000 1.49 50 1.49 50 1.49 1,000 1.49 50 1.49 50 1.49 10,000 1.49 10,000 1.49 1,200 1.49 500 1.49 1,200 1.49 500 121 1.49 10,000 1.49 200 1.49 500 1.49 50 1.49 50 1.49 50 MINIATURE LAMPS (CONTINUED) 40848 14132 12320 20904 /10/540 48/ /540 862 880 Tractor Auto Fog. H27W/1 12.8 12.8 2.93A 2.10A 60 T-31⁄4 Rt Angle Prefocus 43 T-31⁄4 Axial Prefocus 27582 14694 20905 / /540 / /540 48/ /540 880L 880X 881 Auto Fog. H27W/1 Auto Fog. H27W/1 Auto Fog. H27W/2 12.8 12.8 12.8 2.10A 2.10A 2.10A 43 T-31⁄4 Axial Prefocus 43 T-31⁄4 Axial Prefocus 43 T-31⁄4 Rt Angle Prefocus 881L 881X 882 882X 885 886 887 888 889 890 891 892 893 Auto Fog. H27W/2 Auto Fog. H27W/2 Auto Inst. Auto Inst. Auto Fog Auto Fog Tractor Work Light Tractor Work Light Auto – Signal Auto – Signal Auto High Mounted Stop Auto, Signal Auto Fog 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 2.10A 43 T-31⁄4 2.10A 43 T-31⁄4 .35A 3.8 T-21⁄4 .35A 3.8 T-21⁄4 3.90A 100 T-31⁄4 3.90A 100 T-31⁄4 3.90A 95 T-31⁄4 3.90A 95 T-31⁄4 2.10A 43 T-31⁄4 2.10A 43 T-31⁄4 .63A 11 T-21⁄4 1.25A 28 T-31⁄4 2.93A 75 T-31⁄4 893X Auto Fog 12.8 2.93A 75 T-31⁄4 Axial Prefocus C-6 1.25 22112 20238 18455 48/10/540 894 26345 / /540 894X 22113 20914 48/ /540 896 Tractor Tractor Auto Fog 12.8 12.8 12.8 2.93A 2.93A 2.93A 75 T-31⁄4 Rt Angle Prefocus 75 T-31⁄4 Rt Angle Prefocus 75 T-31⁄4 Rt Angle Prefocus C-6 C-6 C-6 1.25 1.25 1.25 12334 27583 / /540 11646 / /540 13158 13161 /10/1000 18167 16772 /10/500 12335 20907 48/ /540 14689 20909 48/ /540 25639 / /540 25703 / /540 12336 20910 48/ /540 12337 20911 48/ /540 12308 15246 15248 48/10/500 16481 /10/ 12338 20913 48/ /540 12727 22111 1.25 1.25 .37 .77 1.25 1.25 1.25 1.25 1.00 1.00 .77 1.00 1.25 12271 / /540 898 Auto Fog 12.8 2.93A 60 T-31⁄4 Rt Angle Prefocus C-6 1.25 12272 48/ /540 899 Auto Fog 12.8 2.93A 60 T-31⁄4 Axial Prefocus C-6 1.25 901 901A 904 906 906A 908 909 912 914 915 916 916NA 917 918 920 921 921XEBP 922 923 926 927 939 Garden & Security 12.8 Garden & Security. Amber 12.8 Auto – Heavy Duty 13.5 Auto – Heavy Duty 13.0 Auto, Side Signal-Amber 13.0 Emergency Lighting 6.0 Emergency Lighting 6.0 Auto – Heavy Duty 12.8 Emergency Lighting 4.0 Emergency Lighting 12.0 Auto, Side Marker 13.5 Auto, Side Marker. Amber 13.0 Home Appliance 12.0 Garden & Security 12.8 Auto 12.8 Auto – Heavy Duty 12.8 Undercabinet Fixture 12.8 Auto – Heavy Duty 12.8 Garden & Security 12.8 Emergency Lighting 4.0 Emergency Lighting 6.0 Emergency Lighting 6.0 C-2R C-2R C-2F C-2F C-2F C-2R C-2R C-2R C-6 C-2R C-2F C-2F C-2F C-2R – C-2R C-2R C-2R C-2R C-2R C-2R C-2R 0.81 0.81 .81 .81 .81 0.81 0.81 .81 0.75 0.81 .81 .81 .81 .81 .81 .81 .81 .81 .81 0.81 0.81 0.81 14273 14007 40675 23024 40462 40463 12366 40289 40290 48505 44754 44755 44756 44757 12365 40504 40505 44769 44771 44772 23025 16288 23026 21860 44801 40179 17837 14008 26199 12307 43374 11743 85938 23027 13274 13275 40180 13483 13485 13486 16975 15285 7-8 / /540 Rt Angle Prefocus Rt Angle Prefocus Socket G-4 Two Pin Axial Prefocus Rt Angle Prefocus Axial Prefocus Rt Angle Prefocus Right Angle Axial G-4 Two Pin Axial Axial Prefocus 1.25 1.25 1.25 48/ /1000 30/ / 48/50/1000 48/50/1000 / /1000 /50/1000 /50/1000 48/50/1000 /50/ /50/1000 48/ /1000 48/50/ / /1000 30/50/2000 48/ / 48/50/1000 25/ / 48/50/1000 30/ / /50/ /50/1000 /50/1000 .31A 2.9 .31A .69A 4 .69A 6 .69A 1.50A 12 .62A 3 1.00A 12 .90A 3.5 .75A 11 .54A 2 .54A 1.5 1.20 10 .56A 6.5 1.20A 10 1.40A 21 18W 21.17 .98A 15 .91A 12.5 1.80A 7.5 1.20A 8 .90A 5.4 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 Wedge Wedge Wedge Wedge Wedge Wedge Wedge Wedge Wedge Wedge Wedge Wedge Wedge Wedge Wedge Wedge Wedge Wedge Wedge Wedge Wedge Wedge For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. Miniature & Sealed Beam Lamps Blister Order Code Case Qty. GE Unit Bulk BP/Unit/Bulk Lamp No. Primary Application Volts Amps or Watts MSCP Bulb Base Filament Design LCL (in) MOL Rated Life Warning (in) (hrs) & Footnotes T-5 B-6 B-6 B-6 S-8 Wedge S.C. Bayonet S.C. Bayonet D.C. Bayonet D.C. Index C-2R C-6 C-6 C-6 C-6 0.81 1.06 1.06 1.06 1.25 1.49 1.75 1.75 1.75 2 RP-11 S-8 S-8 S-8 S-8 RP-11 S-8 S-8 S-8 S-8 S-8 D.C. Bayonet S.C. Bayonet D.C. Bayonet D.C. Pf. (S) S.C. Bayonet S.C. Bayonet S.C. Bayonet S.C. Bayonet D.C. Bayonet D.C. Bayonet D.C. Index C-5 C-6 C-6 C-2R C-6 C-2R C-6 C-6 C-6 C-2R C-6 1.25 1.25 1.25 1.00 1.25 1.25 1.25 1.25 1.25 1.25 1.25 2.25 2.0 2.0 2.0 2.0 2.25 2.0 2.0 2.0 2 2 G-6 S-8 S-8 S-8 S-8 S.C. Bayonet S.C. Bayonet S.C. Bayonet S.C. Bayonet D.C. Index .81 1.25 1.25 1.25 1.25 1.44 2.0 2.0 2.0 2.0 S-8 D.C. Index 1.25 2.0 S-8 D.C. Index 1.25 2.0 S-8 D.C. Index 1.25 2.0 S-8 D.C. Bayonet 1.25 2.0 RP-11 RP-11 S-8 G-6 S-8 G-6 S.C. Bayonet D.C. Bayonet S.C. Bayonet D.C. Bayonet D.C. Bayonet S.C. Bayonet 2C-2R C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-2R C-2R C-2V C-2F C-2V 2C-2V 1.25 1.25 1.25 .69 1.12 .75 2.25 2.25 2.0 1.44 2.0 1.44 D.C. Bayonet 2C-2V S-8 B-6 B-6 G-5 S.C. Bayonet S.C. Bayonet S.C. Bayonet S.C. Bayonet C-2R 1.25 CC-8 1.06 2C-2R 1.06 C-6 .69 2.0 200 1.75 2,000 1.75 300 1.25 20 116 .51A 3.4 B-6 S.C. Bayonet C-6 1.12 1.75 100 116 20W 20W 20W .13A 2.75A – – – .85 11 S.C. Bayonet S.C. Bayonet D.C. Bayonet Miniature Bayonet S.C. Bayonet C-8 CC-8 CC-8 C-2V C-6 – – – .62 1.12 2.63 2.63 2.63 1.19 1.75 300 300 500 250 13 100 MINIATURE LAMPS (CONTINUED) 23684 / /2000 12367 26709 48/50/ 47800 48/ / 12373 26726 26728 48/50/500 26775 /50/ 32147 /10/ 40134 26838 48/50/ 26854 /50/ 37169 /10/ 26872 /10/ 26885 /10/ 12346 26903 26905 48/50/500 47802 48/ / 26917 26919 /50/500 26945 /10/ 12297 48/ / 26955 /50/ 12344 26960 26962 48/50/500 23334 48/ / 21028 20248 48/50/ 12294 26969 26971 48/50/500 23337 48/ / 12310 26975 26976 48/50/500 47798 48/ / 27004 27021 27023 27026 27032 27044 39904 81679 27097 41755 22523 12824 81656 81667 /10/ /50/500 /10/ /10/ /50/ /10/ /50/ /50/ 48/10/ /50/ /50/ /50/ 34265 /50/ 27150 27154 27159 27179 27193 /10/ /10/ /10/ /50/ /10/ 963 1003 1003KR 1004 1034 Emergency Lighting Auto Interior Auto Interior. Long Life Auto Interior and Marine Auto Stop Tail Signal 6.0 12.8 12.8 12.8 12.8 14.0 1062 Special Service 40.0 1073 Auto Signal 12.8 1076 Auto 12.8 1096 Instrument, Microscope 6.0 1129 Special Service 6.4 1133 Instrument 6.2 1141 Auto 12.8 1141KR Auto. Long Life 12.8 1142 Auto 12.8 1152 Special Service 12.8 1154 Auto Stop, Tail, Signal 6.4 7 13.5 1155 Auto, Truck Marker 1156 Auto Stop 12.8 1156KR Auto Stop. Long Life 12.8 1156NA Auto Stop. Amber 12.8 1157 Auto Stop, Signal 12.8 14.0 1157KR Auto Stop, Signal. 12.8 Long Life 14.0 1157NA Amber 12.8 Amber 14.0 1157 Auto Stop, 12.8 NAKR Amber. Long Life 14.0 1176 Auto Stop, Tail, Signal 12.8 14.0 1195 Auto – Nickel-plated base 12.5 1196 Auto 12.5 1203 Special Service 28.0 1224 Marine 34.0 1229 Emergency Lighting 40.0 1251 Instrument, filaments 28.0 in series 1252 Instrument, filaments 28.0 in series 1295NA Auto Signal 12.5 1308 Aircraft Reading 28.0 1309 Aircraft Interior 28.0 1315 Aircraft Emergency 2.5 Lighting 1317 Aircraft Emergency 6.00 Lighting 1383 Auto, Reading Light 13.0 1385 Special Reading Light 28.0 1388 Special Telephone Trouble 24.0 1408 Signal 10.0 1434 Instrument, Photocell 3.7 exciter 2.00A .94A .94A .94A 1.80A .59A .92A 1.80A 1.80A 4.50A 2.63A 3.91A 1.44A 1.44A 1.44A 1.34A 2.63A .75A .59A 2.10A 2.10A 2.10A 2.10A .59A 2.10A .59A 2.10A .59A 2.10A .59A 1.34A .59A 3.00A 3.00A .71A .16A .38A .23A .23A 15 15 15 15 32 3 50 32 32 30 21 32 21 21 21 21 21 3 4 32 32 24 32 3 32 3 24 2.2 24 2.2 21 6 50 50 21 3.8 15 3 3 G-6 3.00A 37 .56A 16 .52A 15 1.00A 1.75 R-12 R-12 R-12 T-31⁄4 T-5 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. .75 50 200 400 200 200 5,000 100 200 200 500 200 200 1,000 2,000 1,000 500 200 1,000 5,000 1,200 2,400 1,200 1,200 5,000 2,400 10,000 1,200 5,000 2,400 10,000 300 1,500 300 300 400 500 400 2,000 305 305 4 305 305 147 1.44 2,000 7-9 Miniature & Sealed Beam Lamps Blister Order Code Case Qty. GE Unit Bulk BP/Unit/Bulk Lamp No. Primary Application Volts Amps or Watts MSCP Bulb Base Filament Design LCL (in) MOL Rated Life Warning (in) (hrs) & Footnotes C-2V C-2V C-2F C-6 C-6 C-2R C-2F C-6 C-2F C-2F C-8Z C-2V C-2V C-6 C-6 C-6 C-6 C-6 CC-6 2C-6 CC-6 C-2V C-2V C-2V C-6 C-6 2C-6 2C-2R 2C-2R 2C-2R C-2F C-2R C-2V C-2F C-2V C-2F C-2F C-2F C-2F C-2F C-2F C-2F C-2F C-2R C-2R C-2F C-2R C-2F C-6 C-2F C-2F .50 .72 .50 1.25 1.25 1.25 .94 1.12 .62 .62 .88 1.12 – 1.25 1.25 1.12 1.00 1.00 1.25 1.25 1.25 .94 .94 .94 2.0 2.0 2.0 1.19 2.0 1.38 1.38 2.38 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1.12 – 1.25 1.25 1.25 1.12 – 1.12 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 .4 2.0 1.19 1.19 1.19 1.19 1.19 1.19 1.19 1.19 1.19 1.19 1.19 1.19 1.19 1.19 1.19 1.19 1.75 1.19 1.19 MINIATURE LAMPS (CONTINUED) 12329 27207 27252 27263 28310 81669 27305 27356 27382 81657 81678 27431 81672 40945 27439 27461 27472 27488 27491 27496 27504 27529 27209 48/50/4000 /50/ /50/ /10/ 37343 /10/500 /10/ /50/ /10/ /10/ /10/ /10/ /10/ /50/ /10/ /10/ /10/ 27489 /10/500 /10/ /10/ /50/ 27530 /10/500 27532 81658 27548 81668 27557 27566 27568 27571 87408 27630 27667 27677 12359 27688 81659 81660 81663 27749 27772 81664 27804 27816 27819 27833 81665 27868 40383 27889 27907 12331 27917 7-10 27679 81661 81666 40384 /50/ /50/ /10/ /10/ /50/ /50/ /50/ /10/ / /1000 /10/ /50/ /50/4000 48/50/ /50/ /50/1000 /50/ /50/ /50/ /50/ /50/ /50/ /50/ /50/ /50/1000 /50/ /50/1000 /10/ /50/ 48/50/ 1445 1449 1450 1460 1460X 1468 1487 1493 1495 1495X 1561 1591 1591AF 1594 1612 1619 1630 1631X 1634 1638 1662 1665 1665AF 1680 1680X 1683 1691 1691AF 1692 1764 1777 1813 1815 1816 1818 1819 1820 1822 1828 1829 1835 1843 1847 1850 1864 1866 1873 1876 1889 1891 Auto / Toy Train Ratings Toy Train Indicator Medical Microscope Illuminator Medical Instrument Indicator Instrument, Microscope Aircraft Aircraft – Gas filled Instrument, Colorimeter Auto Aircraft – All frosted Instrument, Microscope Instrument Instrument Instrument, Microscope Instrument, Colorimeter Instrument, Microscope Marine Aircraft 14.4 14.0 24.0 6.5 6.5 6.0 14.0 6.5 28.0 28.0 6.3 28.0 28.0 6.0 5.4 6.7 6.5 6.5 20.0 28.0 28.0 28.0 Aircraft 28.0 Aircraft – All frosted 28.0 Aircraft 6.0 Aircraft 6.0 Aircraft. Series filament 28.0 Aircraft. Series filament 28.0 Aircraft. Frosted 28.0 Marine 28.0 Aircraft 28.0 Aircraft Tail Light 12.8 Radio 14.4 Indicator 14.0 Aircraft and Auto 13.0 Aircraft 24.0 Indicator 28.0 Indicator 28.0 Indicator 36.0 Indicator 37.5 Indicator 28.0 Indicator 55.0 Indicator 28.0 Radio, TV 6.3 Signal 5.0 Aircraft 28.0 Radio 6.3 Aircraft 28.0 Photoelectric Scanner 3.5 Auto – Heavy Duty 14.0 Auto, Radio and Indicator 14.0 .135A .20A .035A 2.75A 2.75A 4.50A .20A 2.75A .30A .30A 4.00A .61A .61A 5.00A 1.90A 1.90A 2.75A 2.75A 1.00A 1.02A .93A .34A .80A .80A 4.10A 4.10A 1.02A .61A .61A .61A .04A 1.52A .10A .20A .33A .17A .04A .10A .10A .05A .07A .05A .022A .15A .09A .17A .25A .20A 2.50A .27A .24A .7 2 .23 23 23 30 1.4 23 6 6 24 15 – 36 10 15 23 23 24 32 32 6 21 – 32 32 32 15 – 15 .34 26 .86 1.4 3 3.3 .34 1.6 2.1 .65 1 1.1 .2 .38 .25 3 .65 3 6.5 2 2 G-31⁄2 G-31⁄2 G-31⁄2 S-8 S-8 S-8 T-31⁄4 S-8 T-41⁄2 T-41⁄2 S-11 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 T-13⁄4 S-8 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 T-31⁄4 T-5 T-31⁄4 T-31⁄4 Miniature Bayonet Miniature Screw Miniature Bayonet D.C. Pf. (A) D.C. Pf. (A) D.C. Pf. (S) Miniature Screw D.C. Bayonet Miniature Bayonet Miniature Bayonet S.C. Pf. (B) S.C. Bayonet S.C. Bayonet D.C. Bayonet D.C. Bayonet S.C. Bayonet D.C. Pf. (A) D.C. Pf. (A) D.C. Pf. (A) D.C. Bayonet D.C. Index D.C. Index S.C. Bayonet S.C. Bayonet S.C. Bayonet S.C. Bayonet S.C. Bayonet S.C. Bayonet S.C. Bayonet D.C. Bayonet Wire Terminal S.C. Bayonet Miniature Bayonet Miniature Bayonet Miniature Bayonet Miniature Bayonet Miniature Bayonet Miniature Bayonet Miniature Bayonet Miniature Bayonet Miniature Bayonet Miniature Bayonet Miniature Bayonet Miniature Bayonet Miniature Bayonet Miniature Bayonet Miniature Bayonet Miniature Bayonet S.C. Bayonet Miniature Bayonet Miniature Bayonet For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. 1.12 .62 .75 .62 .62 .62 .62 .62 .62 .62 .62 .62 .78 .62 .62 .78 .62 1.12 .56 .62 2,000 250 3,000 100 100 500 3,000 100 500 500 1,500 1,000 1,000 250 1,000 500 100 100 200 500 400 1,000 1,000 1,000 300 300 500 1,000 1,000 1,000 4,000 400 1,000 3,000 1,000 250 2,500 1,000 1,000 3,000 1,000 5,000 3,000 5,000 1,500 1,500 5,000 7,000 2,000 2,000 500 13 13 11 11 11 14 13 13 147 11 11 13, 15, 33 13 13 13 147 13 147 15 44 116 44 Miniature & Sealed Beam Lamps Blister Order Code Case Qty. GE Unit Bulk BP/Unit/Bulk Lamp No. Amps or Watts MSCP Bulb Filament Design LCL (in) Miniature Bayonet Miniature Bayonet Miniature Bayonet S.C. Bayonet S.C. Bayonet S.C. Bayonet C-2F C-2F C-2F C-2V C-8Z C-8Z .62 .62 .56 1.25 1.25 1.25 1.19 1,000 1.19 7,500 1.07 2,000 2.16 300 13, 14 2.16 300 14 2.25 300 14 T-3 T-4 T-3 T-3 T-3 T-3 T-3 T-3 T-3 T-3 T-3 T-3 T-3 T-3 T-4 T-4 T-4 T-3 T-21⁄4 S-8 Two Pin with Leads Tab Wire Terminal Wire Terminals Wire Terminals Wire Terminals Wire Terminals Double Slide Special Sleeve Special Sleeve Wire Terminals Special S.C. Bayonet S.C. Bayonet Two Pin Wire Terminal D.C. Bayonet Special Wire Leads Wedge D.C. Index .87 .75 .285 .285 .285 .285 .285 .41 – – .285 – 1.06 1.00 1.25 1.03 1.18 – .40 1.25 1.46 2.25 1.14 1.14 1.14 1.14 1.14 1.17 2.25 2.25 1.14 2.15 1.88 1.97 1.80 2.00 2.44 2.15 1.25 2.0 S-8 D.C. Index 1.25 2.0 S-8 D.C. Index 1.25 2.0 S-8 D.C. Index S-8 Wire Terminals 1.25 1.25 – 2.0 2.0 1.81 T-21⁄2 T-21⁄2 T-3 S-8 S-8 Miniature Bayonet Miniature Bayonet Wire Terminals Wire Terminals Wire Terminals 0.59 0.59 .285 – – 1.30 1.30 1.14 1.75 1.75 S-8 S-8 S-8 S-8 T-31⁄4 RP-11 S.C. Bayonet S.C. Bayonet S.C. Bayonet S.C. Bayonet Wire Term Down D.C. Pf. (S) CC-6 CC-8 C-6 C-6 C-6 C-6 C-6 C-2V CC-8 CC-8 C-6 C-8 CC-8 CC-6 C-8 CC-6 CC-6 C-8 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-8 C-8 C-6 C-6 CC-6 C-2V CC-8 CC-8 CC-8 CC-8 C-2F C-6 1.19 1.19 1.19 1.19 – 1.18 2.0 2.0 2.0 2.0 1.05 2.25 S-8 D.C. Index 1.25 2.0 S-8 D.C. Index C-6 C-6 C-6 C-6 1.25 2.0 Primary Application Volts Auto and Indicator Auto – Heavy Duty Auto, Truck Marker Aircraft Marker Aircraft Marker Special Service silver contact Aircraft Aircraft Special Service Aircraft Special Service Special Service Medical Aircraft Gunsight Aircraft Aircraft Instrument Aircraft Navigation Aircraft Navigation Aircraft – Quartz Bulb Aircraft – Navigation Aircraft – Quartz bulb Aircraft – Quartz bulb Aircraft Gunsight Auto Light Bar Auto Stop, Signal 14.4 14.0 14.0 28.0 14.0 14.0 .12A .33A .27A 1.79A 3.57A 3.57A .75 2 2 70 75 75 T-31⁄4 T-31⁄4 G-41⁄2 T-7 T-7 T-7 28.0 28.0 8.5 8.5 8.5 8.5 8.5 28.0 28.0 28.0 6.0 10.0 28.0 28.0 10.0 28.0 28.0 10.0 12.8 12.8 14.0 12.8 14.0 12.8 14.0 12.8 14.0 12.8 14.0 12.0 12.0 7.0 12.8 28.0 28.0 28.0 28.0 28.0 28.0 14.0 5.9 6.2 12.8 14.0 12.8 14.0 250W 150W 62W 62W 62W 62W 62W 25W 100W 100W 20W 100W 75W 75W 100W 250W 150W 100W .625A 2.10A .48A 2.10A .48A 2.10A .48A 2.10A .48A 2.10A .48A .833A .833A 25W 2.10A .93A .34A .643A .643A .643A .766A .35A 4.66A 4.49A 2.20A .59A 2.20A .59A 660 250 110 110 80 80 110 15 150 140 10 130 110 107 130 600 240 130 10.5 32 2 32 2 24 1.5 24 1.5 32 2 9.1 8 24 32 32 6 18 18 – 21 2.7 32 32 40 3 30 2.2 Base MOL Rated Life Warning (in) (hrs) & Footnotes MINIATURE LAMPS (CONTINUED) 27927 /50/ 1892 12332 27935 27937 48/50/4000 1893 12330 27945 27948 48/50/4000 1895 34021 /10/ 1939X 28008 /10/ 1940 45087 /10/ 1944X 18617 28011 39641 /10/ /10/ /10/ 12859 / /100 37947 / /100 44152 /10/ 13667 /10/ 28034 /10/ 28036 /10/ 41938 /10/ 32780 /10/ 38545 /10/ 38627 /10/ 21061 /10/ 39718 /10/ 44717 /10/ 47695 /10/ 38535 /10/ 12326 19280 48/10/ 12296 44760 18620 48/50/500 1946 1958 1962B 1962BG 1962DX 1962DZ 1962TY 1968 1970 1970X 1974 1978X 1982 1982SP 1983 1986 1987 1988 2040 2057 23339 2057KR 10018 48/ /500 12312 44763 44764 48/50/500 47799 48/ / Auto Stop, Signal. Long Life 2057NA Auto Stop, Signal. Amber 12899 / /600 2057 NAKR 2058U 28085 32701 /10/ /10/ /10/ / /600 / /500 2059 2059X 2074 2144 2155 Aircraft-Reading Lamps Aircraft-Reading Lamps Instrument Auto/Truck Truck /50/ /50/ /10/ /10/ / /1000 /10/ 2232 2232LL 2232SB 2233 2286D 2331 Aircraft Aircraft Long Life Aircraft. Reflectorized Aircraft Auto/Truck Instrument 12298 16291 16290 48/50/500 2357 Auto Stop, Signal 12299 15698 15699 48/50/500 2357NA Auto Stop, Signal. Amber 26697 26698 21494 34763 26702 81677 36906 44964 28100 Auto Stop. Amber. Long Life Auto/Truck Stop, Signal For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. 50 300 50 50 150 150 50 500 1,000 1,000 10,000 2,000 1,000 2,000 2,000 100 700 2,000 500 1,200 5,000 2,400 10,000 1,200 5,000 2,400 10,000 1,200 5,000 4,000 4,000 2,700 1,200 400 1,000 2,000 4,000 2,000 2,000 1,500 400 400 400 5,000 400 5,000 304 304 304 304 304 304 304 13, 304 304 13, 304 304 304 13, 304 304 304 304 304 304 306 113 304 304 304 113 13, 15 305 7-11 Miniature & Sealed Beam Lamps Blister Order Code Case Qty. GE Unit Bulk BP/Unit/Bulk Lamp No. Primary Application Volts Amps or Watts MSCP Bulb 12.8 12.8 14.0 28.0 28.0 5.0 2.23A 40 S-8 2.23A 40 S-8 .48A 2 200W 525 T-3 250W 600 T-4 2.00A TL-23⁄4 28.0 12.8 14.0 12.8 14.0 12.8 14.0 10.0 12.8 12.8 12.8 12.8 14.0 12.8 14.0 12.8 14.0 12.8 14.0 12.8 14.0 12.8 14.0 12.8 14.0 12.8 14.0 12.8 13.5 12.8 14.0 12.8 14.0 A.C. A.C. A.C. A.C. A.C. A.C. A.C. A.C. A.C. A.C. A.C. A.C. A.C. A.C. 1.29A 2.10A .48A 2.10A .48A 2.10A .48A 100W 1.60A 2.10A 2.10A 2.10A .59A 2.10A .59A 2.10A .59A 2.10A .59A 2.10A .59A 2.10A .59A 2.10A .59A 2.10A .59A 2.10A .37A 2.23A .59A 2.23A .59A 4W 4W 8W 8W 13W 13W 4W 4W 6W 6W 8W 8W 13W 13W Base Filament Design LCL (in) C-6 C-6 C-6 CC-6 CC-6 C-6 1.25 1.25 MOL Rated Life Warning (in) (hrs) & Footnotes MINIATURE LAMPS (CONTINUED) 18047 /10/ 48/ / 2396 2397 Auto Stop Auto Stop, Signal 43805 / /100 / /100 /10/ 2556 2586 2604X Aircraft Aircraft Instrument – Lens end 36508 12305 18389 /10/ 48/50/ 3011 3057 Aircraft Auto Stop, Signal 26378 48/ / 3057KR 12313 18391 48/50/ Auto Stop, Signal. Long Life 3057NA Auto Stop, Signal. Amber 14698 23028 12351 21863 27565 12306 17172 /10/ 48/ / 48/50/ 48/ / 48/50/ 3078 3155 3156 3156KR 3157 26377 48/ / 3157KR 12314 17173 48/50/ 26380 48/ / 14387 22525 48/50/ 3157 Stop, Signal. Amber. NAKR Long Life 3357/3457 Auto Stop, Signal 26379 48/ / 3457KR 14388 22526 48/50/ 25834 48/ / Auto Stop, Signal. 3357 Sub 3357NA/ Auto Stop, Signal. 3457NA 3457NA Sub 3496 Auto Japanese Vehicles 25835 25837 15657 48/ / 48/ / 48/ / 3497 3652 4157KR 47458 48/ / 4157 NAKR 5004CW 5004WW 5008CW 5008WW 5013CW 5013WW 5104CW 5104WW 5106CW 5106WW 5108CW 5108WW 5113CW 5113WW 27560 19792 19566 28154 28155 28160 28163 28168 28169 27367 28173 12774 33612 27466 28175 12775 28178 7-12 /24/ /24/ /24/ /24/ /24/ /24/ /24/ /24/ /24/ /24/ /24/ /24/ /24/ /24/ Aircraft Navigation Auto Signal Auto Stop Auto Stop. Long Life Auto Stop, Signal Auto Stop, Signal. Long Life 3157NA Auto Stop, Signal. Amber Auto Japanese Vehicles Auto-Japanese Vehicles Auto Stop, Signal. Long Life Stop, Signal. Amber. Long Life Aircraft – Cool White Aircraft – Warm White Aircraft – Cool White Aircraft – Warm White Aircraft – Cool White Aircraft – Warm White Aircraft – Cool White Aircraft – Warm White Aircraft – Cool White Aircraft – Warm White Aircraft – Cool White Aircraft – Warm White Aircraft – Cool White Aircraft – Warm White 44 2 2 32 2 24 1.5 95 21 32 32 32 3 32 3 24 2.2 24 2.2 40 3 40 3 30 2.2 43 3 45 6 32 3 24 2.2 11.9 11.1 35.4 34.6 65.2 62.8 11.9 11.1 24.7 23.9 35.4 34.6 65.2 62.8 S.C. Bayonet D.C. Index Two Pin Two Pin with Leads G-4 Two Pin S-11 S-8 S.C. Bayonet Plastic Wedge S-8 Plastic Wedge S-8 Plastic Wedge T-3 S-8 S-8 S-8 S-8 Special Plastic Wedge Plastic Wedge Plastic Wedge Plastic Wedge S-8 Plastic Wedge S-8 Plastic Wedge S-8 Plastic Wedge S-8 Plastic Wedge S-8 Plastic Wedge S-8 Plastic Wedge T-7 D.C. Index T-7 S.C. Bayonet T-31⁄4 Wedge S-8 Plastic Wedge S-8 Plastic Wedge T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 Miniature Pinless Miniature Pinless Miniature Pinless Miniature Pinless Miniature Pinless Miniature Pinless Miniature BiPin Miniature BiPin Miniature BiPin Miniature BiPin Miniature BiPin Miniature BiPin Miniature BiPin Miniature BiPin C-2V C-6 C-6 C-6 C-6 C-6 C-6 C-8 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 – C-6 C-6 C-6 C-6 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. .87 1.30 – 1.25 1.10 1.1 1.10 – 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 – – – 1.10 1.10 1.10 2.0 2.0 400 400 5,000 1.46 50 304 1.90 100 304 1.18 5,000 124, 128, 306 2.38 1,000 13 2.09 1,200 5,000 2.09 2,000 10,000 2.09 1,200 5,000 2.15 4,500 304 2.09 1,500 2.09 1,200 2.09 2,000 2.09 1,200 5,000 2.09 2,000 10,000 2.09 1,200 5,000 2.09 2,000 2.09 10,000 2.09 400 5,000 2.09 800 10,000 2.09 400 5,000 2.00 600 5,000 2.00 600 1.06 700 2.09 3,600 10,000 2.09 3,600 2.09 10,000 6.00 7,500 32, 162, 309 6.00 7,500 32, 162, 309 12.00 7,500 32, 162, 309 12.00 7,500 32, 162, 309 21.00 7,500 32, 162, 309 21.00 7,500 32, 162, 309 6.00 7,500 32, 162, 309 6.00 7,500 32, 162, 309 9.00 7,500 32, 162, 309 9.00 7,500 32, 162, 309 12.00 7,500 32, 162, 309 12.00 7,500 32, 162, 309 21.00 7,500 32, 162, 309 21.00 7,500 32, 162,309 Miniature & Sealed Beam Lamps Blister Order Code Case Qty. GE Unit Bulk BP/Unit/Bulk Lamp No. Primary Application Volts Amps or Watts MSCP Bulb Base Filament Design LCL (in) MOL Rated Life Warning (in) (hrs) & Footnotes MINIATURE LAMPS (CONTINUED) 29897 29895 87360 87351 87291 29893 29894 87274 87402 97548 / /1000 / /1000 / /1000 / /1000 / /1000 / /1000 / /1000 / /1000 / /1000 / /1000 28926 /50/ 26200 48/ / 26201 10014 48/ /1000 22432 22389 14542 48/100/200 45470 48/ / 18508 13382 18699 48/100/250 27561 48/ / 45471 48/ / 13993 11249 20559 48/100/250 18509 13384 14710 48/100/200 48/ / 45472 45866 48/ / 18510 13397 14711 48/100/200 47640 48/ / 45473 48/ / 45868 22388 20551 48/ / 48/100/ 47642 48/ / 10209 45474 40843 45591 47461 / /250 48/ / 14776 / /360 47327 41495 / /900 / /360 37735 48/ /200 48/ / 48/ / 6034BP Aircraft 6034BPGPL Aircraft 6832 Aircraft 6832AS15 Aircraft 6839 Aircraft 6839BPE Aircraft 6839BPEGPL Aircraft 7132AS15 Aircraft 7152 Aircraft 7152AS15 Aircraft 7387 Indicator 7440 Auto Japanese Vehicles 7443 Auto Japanese Vehicles 28.0 28.0 5.0 5.0 28.0 28.0 28.0 5.0 5.0 5.0 28.0 13.5 13.5 13.5 9003/HB2 Headlamp Type HB2/H4 12.8 12.8 9003SB Headlamp. White Light. 12.8 12.8 9004/HB1 Headlamp. Type HB1 12.8 12.8 9004HO Headlamp. HB1. 12.8 Higher output. 12.8 9004SB Headlamp. HB1. 12.8 White Light. 12.8 9004XL Headlamp Long life. HB1 12.8 12.8 9005/HB3 Headlamp. High Beam. 12.8 HB3 9005SB Headlamp. High. 12.8 White Light 9005XSLL Headlamp. High. HB3A. 12.8 9006/HB4 Headlamp, Low Beam. 12.8 HB4 9006HO Headlamp. Low. 12.8 Higher Output 9006SB Headlamp. Low. HB4. 12.8 White Light 9006XSLL Headlamp, Low. HB4A. 12.8 12.8 9007/HB5 Headlamp High/Low. Type HB5. 12.8 9007HO Headlamp High/Low. 12.8 High Output. 12.8 9007LL Headlamp High/Low. 12.8 Long life 12.8 9007SB Headlamp High/Low. 12.8 White Light 12.8 9011 Headlamp High. HIR1. 12.8 Infrared. 9011X HIR Headlamp High. Infrared. 12.8 9012 Headlamp Low. HIR2. 12.8 (HIR2) Infrared 9145 (H10) Auto Fog ECE H10 12.8 56110 Auto-Interior-12V 20W 13.2 58540 Auto-Interior-12V 5W 13.5 .024A .15 T-13⁄4 .024A .15 T-13⁄4 .06A .05 T-1 .06A .05 T-1 .024A .15 T-1 .024A .15 T-1 .024A .15 T-1 .075A .09 T-1 .115A .15 T-1 .115A .15 T-1 .04A .3 T-13⁄4 1.85A 37 T-7 1.85A 35 T-7 .4A 3 67W 119 T-43⁄4 60W 72 67W 119 T-43⁄4 60W 72 65W 95 T-43⁄4 45W 55 65W 95 T-43⁄4 42W 56 65W 95 T-43⁄4 45W 56 65W 95 T-43⁄4 47W 55 65W 135 T-4 BiPin BiPin Short Wire Terminal Short Wire Terminal Sub-Midget Flanged BiPin BiPin Short Wire Terminal Short Wire Terminal Short Wire Terminal BiPin M-23 Wedge / 103 x 16DQ Wedge / 103 x 16DQ Rt Angle Prefocus C-2F C-2F C-2R C-2R CC-2F CC-2F CC-2F C-2R C-2R C-2R C-2F C-6 C-6 C-6 C-8 C-8 C-8 C-8 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-8 65W 135 T-4 Rt Angle Prefocus 65W 55W 135 T-4 80 T-4 55W 55W 1.24 .64 5,000 .64 5,000 .14 100,000 .14 100,000 .36 16,000 .35 16,000 .35 16,000 .14 40,000 .14 40,000 .14 40,000 .61 7,000 1.75 300 1.75 500 1.75 1,000 3.62 150 800 3.62 80 150 4.17 150 320 4.17 150 640 4.17 40 200 4.17 150 850 3.13 800 C-8 1.24 3.13 150 4, 75, 306 Axial Prefocus Rt Angle Prefocus C-8 C-8 1.24 1.24 3.13 3.13 700 4, 306 850 4, 306 80 T-4 Rt Angle Prefocus C-8 1.24 3.13 1000 4, 306 80 T-4 Rt Angle Prefocus C-8 1.24 3.13 1.24 1.75 1.75 1.75 1.25 3.13 2,000 4, 306 4.17 150 4, 161, 306 1,100 4.17 150 4, 161, 306 320 4.17 150 4, 161, 306 1,450 4.17 110 4, 161, 306 4.17 250 3.50 150 4, 306 P43T-38 P43T-38 Axial Prefocus Axial Prefocus Axial Prefocus Axial Prefocus 1.12 1.75 1.75 1.75 1.75 79 4, 306 4, 306 4, 161, 306 4, 161, 306 4, 161, 306 4, 161, 306 4, 306 320 4, 75, 306 55W 65W 55W 65W 53W 65W 55W 65W 58W 65W 80 107 79 107 80 107 79 107 80 183 T-31⁄4 PX20D C-8 C-8 C-8 C-8 C-8 C-8 C-8 C-8 C-8 C-8 65W 55W 183 T-31⁄4 PX20D 135 T-31⁄4 PX 22D C-8 C-8 1.25 1.25 3.50 2.8 C-8 C-2R C-2R 1.24 .59 .59 3.01 1,500 4, 306 1.22 100 308 1.22 240 308 45W 1.83A .37A T-4 Axial Prefocus T-43⁄4 Axial Prefocus .50 – – – 1.12 T-43⁄4 Axial Prefocus T-43⁄4 Axial Prefocus T-43⁄4 Axial Prefocus 65 T-4 40 T-3 63 T-3 PY20D Miniature Bayonet Miniature Bayonet For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. 1.75 1.75 150 4, 306 900 4, 306 7-13 Miniature & Sealed Beam Lamps Blister Order Code Case Qty. GE Unit Bulk BP/Unit/Bulk Lamp No. Primary Application Volts Amps or Watts MSCP Bulb Base Filament Design LCL (in) MOL Rated Life Warning (in) (hrs) & Footnotes MINIATURE LAMPS (CONTINUED) 26696 /10/ 12064 12065 31675 16124 /10/ /10/ /10/ 48/ / / /144 15999 / /144 23312 25323 48/ / 12353 48/ / 12354 12084 48/50/ 12085 /10/ 23324 48/ / 40336 27328 32376 48/10/300 27569 /10/ 27329 /10/ 27330 23442 12339 27331 22132 23445 35044 23428 27332 23438 12341 /10/ / /400 48/10/400 / /400 / /400 / /400 /10/400 48/ / 18132 27334 22133 48/10/200 27342 30833 /10/200 35755 15765 15827 15828 15963 48/ /200 / /300 / /300 / /300 / /300 48/ / 48/ / 48/ / 48/ / /48/ 26374 22961 23151 23153 23154 12571 23306 27561 11601 48/ /1000 38655 / /1000 30857 48/ /1000 23303 11604 48/ /1000 92475 40778 7-14 / /1000 /10/ A-103 Aircraft-Quartz Bulb28.0 Navigation B1A Neon Glow (NE-51) 120 B2A Neon Glow (NE-51H) 120 B7A Neon Glow (NE-45) 120 C5W Auto. ECE C5W 13.5 D2R Low Beam Reflector 85 System D2S Low Beam Projector 85 System DE3021 Dome & Courtesy 14.0 DE3022 Dome & Courtesy 13.0 DE3175 Dome & Courtesy 13.0 DE3425 Dome & Courtesy 13.0 DE7576 Strip. Auto DIN 72601K 13.5 H1-55 Auto ECE. GE50310/1 13.2 H1-70/28V Auto. ECE. GE50320/1 28.0 H1-100 Off Road Auxiliary. 13.2 GE52140 H2-55 Auto .GE50410 13.2 H3-35 C.I.M. GE50390 13.2 H3-55 Auto ECE. GE50340 13.2 H3-55HD C.I.M. GE50340HD 13.2 H3-55LL Auto ECE GE50340LL. 13.2 Long Life H3-65/28V C.I.M. GE52590HD 28.0 H3-70/28V C.I.M. GE50350 28.0 H3-100 Off Road Auxiliary. 13.2 GE52130 H4-60/55 Auto. GE50440 13.2 13.2 H4-75/ Bus GE50450 28.0 70/28V 28.0 H7-55 Auto ECE, DOT GE58520 13.2 H8 Auto ECE Fog 13.2 H9 Auto ECE High Beam 13.2 H11 Auto ECE Low Beam 13.2 H11LL Auto ECE Low Beam 13.2 KPR102 Flashlight – 2D Krypton 2.4 KPR104 Flashlight – 2D Krypton 2.2 KPR113 Flashlight – 4D Krypton 4.8 KPR118 Flashlight – 6D Krypton 7.2 ML20/ Aircraft. Lumiline. 28.0 OF-28 Frosted P21W Auto Stop. (ECE). P25-1. 13.5 P21W LL Auto Stop (ECE). Long Life 13.5 P21/4W Auto Stop, Signal. 13.5 (ECE) 13.5 P21/5W Auto Stop, Signal. (ECE). 13.5 P25-2. 13.5 P21/5W Auto Stop, Signal. 13.5 LL Long Life 13.5 P21W 24V Bus Stop-European (ECE) 28.0 50W 60 T-3 Special CC-8 – 1.87 1,000 304 1/25W T-31⁄4 1/7W T-31⁄4 1/4W T-41⁄2 .37A 3.6 T-31⁄2 35W 114 T-3 Miniature Bayonet Miniature Bayonet Candelabra Screw SV8.5/8 P32d-3 – 1.06 1.19 1.19 1.53 1.45 3.09 35W 254 T-3 P32d-2 – 1.06 3.09 1,000 1, 2, 310 .24A .38A .77A .77A .74A 62W 80W 100W 2 3 9.55 9.55 9.8 123 151 219 T-21⁄4 T-21⁄4 T-31⁄4 T-4 T-31⁄2 T-31⁄2 T-31⁄2 T-31⁄2 SV7MM SV7MM SV8.5MM SV8.5MM SV8.5/8 P14.5S P14.5S P14.5S C-8 C-8 C-8 1.08 1.08 1.08 1.15 1,000 1.18 1,000 1.25 400 1.50 400 1.65 200 2.66 225 308 2.46 600 308 2.66 100 308 62W 40W 62W 62W 64W 143 60 115 111 106 T-31⁄2 T-31⁄2 T-31⁄2 T-31⁄2 T-31⁄2 X511 PK22S PK22S PK22S PK22S C-8 C-6 C-6 C-6 C-6 .48 .71 .71 .71 .71 1.22 225 1.65 200 1.65 225 1.65 600 1.65 2,000 66W 75W 92W 102 T-31⁄2 PK22S 135 T-31⁄2 PK22S 187 T-31⁄2 PK22S C-6 CC-6 C-6 .71 .71 .71 1.65 1,000 308 1.65 225 308 1.65 100 308 71W 66W 80W 73W 56.5W 40W 65W 55W 55W .70A .47A .75A .55A 20W 138 80 151 95 115 64 167 107 107 1.3 .47 4.1 5.2 – C-8 C-8 C-8 C-8 C-8 C-8 C-8 C-8 C-8 C-2R C-2R C-2R C-2R 2C-8 1.12 3.62 1.14 3.62 .98 1.06 1.08 1.07 1.07 .25 .25 .25 .25 – 2.36 2.63 2.63 2.63 2.63 1.25 1.25 1.25 1.25 5.75 1.85A 1.85A 1.85A .37A 1.85A .44A 1.85A .44A 1.00A 36.6 36.6 35 1.19 35 2.78 35 2.78 36.6 1.25 1.25 1.25 2.0 2.0 2.0 1.25 2.0 1.25 1.25 1.25 2.0 2.0 2.0 T-5 P43T-38 T-5 P43T-38 T-31⁄2 T-31⁄2 T-31⁄2 T-31⁄2 T-31⁄2 B-31⁄2 B-31⁄2 B-31⁄2 B-31⁄2 T-8 PX26D PGJ19-1 PGJ19-5 PGJ19-2 PGJ19-2 S.C. Miniature Flanged S.C. Miniature Flanged S.C. Miniature Flanged S.C. Miniature Flanged Disk S-8 S-8 S-8 S.C. Bayonet S.C. Bayonet D.C. Index S-8 D.C. Index S-8 D.C. Index S-8 S.C. Bayonet C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 C-6 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. 15,000 25,000 7,500 450 1,000 225 900 150 300 500 400 125 550 1,400 15 15 20 15 500 250 300 100 100 250 1,000 600 3,000 150 164 164 164 1, 2, 310 308 308 308 308 308 306 308 308 2, 308 2, 308 2, 308 4, 308 116 116 116 116 12 Miniature & Sealed Beam Lamps Blister Order Code Case Qty. GE Unit Bulk BP/Unit/Bulk Lamp No. Primary Application Volts Amps or Watts MSCP Bulb Base Filament Design LCL (in) MOL Rated Life Warning (in) (hrs) & Footnotes 1.25 2.0 .45 .45 .45 .25 .25 .25 .25 .25 .25 .25 .25 1.25 .75 .75 .59 1.11 1.11 1.11 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 2.0 1.47 1.47 1.08 1.11 1.11 1.69 1.11 1.19 1.11 1.69 1.11 1.19 1.11 1.19 MINIATURE LAMPS (CONTINUED) 30856 / /1000 23036 / /1000 27222 23037 /10/1000 72221 23021 /10/1000 12675 25181 48/50/ 12676 25193 48/50/ 12677 48/ / 25222 /50/ 25235 /50/ 12680 25252 48/50/ 12681 25262 48/50/ 25289 /50/ 41370 32648 48/ /500 23314 30859 48/ /2000 23322 35417 48/ /2000 23318 48/ / 12756 /50/ 12760 /50/ 29001 /50/ 12071 /50/ 12761 /50/ 12072 /50/ 29041 /50/ 12075 /50/ 12076 /50/ 12077 /50/ 12078 /50/ 12080 27562 27563 /50/ 35030 48/ /2000 37640 48/ /2000 26353 / /1000 P21/5W Bus Stop /Tail. (ECE) 28.0 28.0 PC161 Auto Instrument 14.0 PC168 Auto Instrument 14.0 PC194 Auto Inst. & Ind., H.D. 14.0 PR2 Flashlight – 2D Cells 2.38 PR3 Flashlight – 3D Cells 3.57 PR4 Flashlight – 2C Cells 2.33 PR6 Flashlight – 2D Cells 2.47 PR7 Flashlight – 3D Cells 3.70 PR12 Flashlight – 5D Cells 5.95 PR13 Lantern – 4F Cells 4.75 PR18 Flashlight – 6D Cells 7.20 PY21W Auto Stop. (ECE) – Amber 13.5 R5W LL Auto. ECE R5W GE 2619 13.5 R10W LL Auto. ECE R10W GE 2641 13.5 T4W Auto. ECE T4W GE 2662 13.5 TEL/6PSB Indicator 6.0 TEL/12PSB Indicator 12.0 TEL/24E2 Telephone 24.0 TEL/24PSBIndicator 24.0 TEL/28MB Indicator 28.0 TEL/28PSB Indicator 28.0 TEL/48C2 Telephone 48.0 TEL/48PSB Indicator 48.0 TEL/60MB Indicator 60.0 TEL/60PSB Indicator 60.0 TEL/ Indicator 120.0 120MB TEL/ Indicator 120.0 120PSB W3W Auto-European ECE 13.5 W5W Auto-European ECE 13.5 W16W Auto ECEW16W 13.5 1.00A 35 .36A 3.18 .19A 1 .35A 3 .27A 2 .50A .8 .50A 1.5 .27A .4 .30A .45 .30A .9 .50A 3.1 .50A 2.2 .55A 5.5 1.85A 22.3 5W 4.0 10W 10.0 .30A 2.8 .14A 550 .17A 2,000 .035A 600 .073A 3,000 .04A .29 .04A 1,600 .035A 750 .05A 1,800 .05A .73 .05A 1,800 .025A .36 S-8 D.C. Index T-31⁄4 T-31⁄4 T-31⁄4 B-31⁄2 B-31⁄2 B-31⁄2 B-31⁄2 B-31⁄2 B-31⁄2 B-31⁄2 B-31⁄2 S-8 G-6 G-6 T-23⁄4 T-2 T-2 T-2 T-2 T-21⁄2 T-2 T-2 T-2 T-21⁄2 T-2 T-21⁄2 Printed Circuit Socket Printed Circuit Socket Printed Circuit Socket S.C. Miniature Flanged S.C. Miniature Flanged S.C. Miniature Flanged S.C. Miniature Flanged S.C. Miniature Flanged S.C. Miniature Flanged S.C. Miniature Flanged S.C. Miniature Flanged S.C. Bayonet S.C. Bayonet S.C. Bayonet Miniature Bayonet Tel. Slide #5 Tel. Slide #5 Tel. Slide #3 Tel. Slide #5 Miniature Bayonet Tel. Slide #5 Tel. Slide #3 Tel. Slide #5 Miniature Bayonet Tel. Slide #5 Miniature Bayonet C-6 C-6 C-2F C-2F C-2F C-2R C-2R C-2R C-2R C-2R C-2R C-2R C-2R C-6 C-2R C-2R C-2R C-2V C-2F C-2F C-2F C-2F C-2F C-2F C-7A C-7A C-7A CC-7A Tel. Slide #5 CC-7A .025A 1,000 T-2 3W 1.75 T-31⁄4 Wedge 5W 4 T-31⁄4 Wedge 1.44A 24.6 T-5 Wedge C-2V C-2V C-2F For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. – – – 150 1,500 4,000 1,500 2,500 15 15 10 30 30 15 15 3 250 500 400 450 20,000 12,000 7,000 10,000 5,000 5,000 5,000 10,000 7,500 7,500 7,500 116 116 116 116 116 116 116 14, 116 80 80 80 80 80 80 80 80 1.11 7,500 80 .5 .5 .81 1.06 1,000 13 1.06 300 13 1.49 250 121 7-15 Miniature & Sealed Beam Lamps Order Code Case Qty. GE Unit Bulk Unit/Bulk Lamp No. Bulb Primary Application Design Design Volts Watts MBCP Base MOL Rated Spread to 10% MBCP Warning (in) Life (hrs) Horiz Vert & Footnotes SEALED BEAM 18511 6 4000 PAR46 24327 24339 24338 24369 38418 12 12/60 12 12 4013 4014 4019 4040 PAR46 PAR36 PAR46 PAR46 39585 40588 10540 25051 39366 39362 12961 24425 24430 24439 24448 37889 12/60 12/60 12/60 12 12/60 12/60 12 12/60 12/60 12 12/60 12/60 60 12/24 12/24 12/24 12/60 12 12/60 12/60 12/60 12/60 12 12 12/24 12/24 12 12 12/24 12 12/60 4042 4044 4044-1 4313 4340 4350 4402A 4405 4406 4410 4411 4411-1 4411-3 4412 4412A 4413 4414 4414R 4415 4415A 4416 4416-1 4416A 4416R 4419 4421 4422 4434A 4435 4436 4440X PAR36 PAR36 PAR36 PAR36 PAR36 PAR36 PAR36 PAR36 PAR36 PAR36 PAR36 PAR36 PAR36 PAR46 PAR46 PAR46 PAR36 PAR36 PAR36 PAR36 PAR36 PAR36 PAR36 PAR36 PAR46 PAR46 PAR36 PAR46 PAR46 PAR46 PAR36 39586 40589 10541 39367 39363 24423 24428 24443 37890 48032 24453 24459 24464 24477 24454 24460 22981 24478 24487 22982 24490 24499 24497 22983 24503 34901 24506 24513 24531 24525 24539 24541 24542 24572 24577 24576 24582 39932 39933 39748 12 4440X-1 PAR36 37046 37047 40176 12/60 12 4446 4460X PAR36 PAR36 24592 24596 24613 24627 24640 24638 24650 24649 41503 12 12 12 12 12/60 12/60 12 4461 4466 4478 4502 4505 4509 4509X PAR36 PAR36 PAR46 PAR36 PAR36 PAR36 PAR36 7-16 Headlamp, Low Beam Type 2C1 Tractor, Flood Emergency Bldg. Lighting Tractor Headlamp, Low. Type 2C1 12.8 12.8 6.4 6.4 6.2 12.8 12.8 Emergency Bldg. Lighting 6.4 Emergency Bldg. Lighting 12.0 Emergency Bldg. Lighting 12.0 Aircraft Landing 13.0 Electric Truck Work Light 48.0 Electric Truck Work Light 36.0 CIM Signal 28.0 Spotlight 12.8 Tractor, Flood 12.8 Backup Lamp, Tractor Flood 12.8 Tractor 12.8 Tractor 12.8 Tractor 12.8 Fog 12.8 Fog, Yellow 12.8 Tractor, Flood 12.8 Warning Signal, Garden 12.8 Warning Signal Red Lens 12.8 Fog 12.8 Fog, Yellow Lens 12.8 Spotlamp, Signal 12.8 Spotlamp, Signal 12.8 Signal, Yellow Lens Cover 12.8 Signal, Red Lens Cover 12.8 Tractor 12.8 Auto/Truck, Special 13.0 Tractor 12.8 Bus Signal, Amber Lens 12.8 Spotlamp 12.8 Signal 12.8 Tractor 12.8 12.8 Tractor 12.8 12.8 Emergency Bldg. Lighting 12.8 Tractor 12.8 12.8 Tractor 12.8 Tractor 12.8 C.I.M. Flood 13.0 Auto Headlamp, Military 28.0 Aircraft Navigation 28.0 Aircraft Landing Spotlamp 13.0 Marine Spotlamp 13.0 37.5W 60W 25W 18W 30W 37.5W 60W 12W 12W 12W 250W 80W 60W 50W 30W 35W 35W 35W 35W 35W 35W 35W 35W 18W 18W 35W 35W 30W 30W 30W 30W 35W 100W 35W 40W 30W 35W 40W 40W 40W 40W 25W 40W 40W 60W 60W 60W 50W 50W 100W 100W SAE 3 Contact Lugs 4 800 1,500 1,200 SAE Screw Terminals Screw Terminals Screw Terminals 3 Contact Lugs 3.75 2.75 3.75 4 1,100 1,100 1,100 140,000 2,500 2,100 1,000 50,000 600 600 3,000 3,000 3,000 11,000 8,800 1,100 1,500 275 9,000 7,000 35,000 35,000 26,000 4,000 1,600 23,000 600 1,000 75,000 60,000 6,000 4,500 6,000 4,500 400 6,500 5,000 6,000 1,000 1,600 10,000 45,000 110,000 110,000 Screw Terminals Screw Terminals Slip-on Terminals Screw Terminals Slip-on Terminals Slip-on Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Slip-on Terminals Combination Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Slip-on Terminals Screw Terminals Screw Terminals Screw Terminals Slip-on Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals 3 Contact Lugs 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 3.75 3.75 3.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 3.75 3.75 2.75 3.75 3.75 3.75 3 3 Slip-on Terminals 2.75 Screw Terminals 3 Screw Terminals 2.75 2.75 Screw Terminals Screw Terminals 2 Contact Lugs Screw Terminals Screw Terminals Screw Terminals Screw Terminals 2.75 2.75 4 2.75 2.75 2.75 2.75 200 320 300 200 300 300 500 150 150 150 25 400 400 400 100 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 100 100 300 320 320 320 320 300 320 320 300 300 800 400 400 25 25 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. 4 80 20 50 25 Trapezoidal 45 20 50 25 50 25 16 7 Trapezoidal Trapezoidal 50 25 6 5 80 30 80 30 Trapezoidal Trapezoidal Trapezoidal 40 7 40 7 80 20 50 25 50 25 40 5 40 5 11 4 11 4 11 4 11 4 Trapezoidal 50 7 75° Cone 55 25 5 5 10 4 40 7 33 9 40 7 33 9 80 80 22 10 22 13 Trapezoidal 80 30 56 32 40 7 11 5 12 6 12 6 23 4 302 15 15 167 4 4 4 4 4 167 167 4 167 167 4 109, 167 4 167 4 4 4 4 4 4 167 167 Miniature & Sealed Beam Lamps Order Code Case Qty. GE Unit Bulk Unit/Bulk Lamp No. Bulb Primary Application Design Design Volts Watts MBCP Base MOL Rated Spread to 10% MBCP Warning (in) Life (hrs) Horiz Vert & Footnotes SEALED BEAM (CONTINUED) 11524 24654 24653 24663 24661 24673 24671 24678 24690 24700 24721 24726 19628 24735 24742 40822 39022 24756 24764 24768 24780 24770 24788 24795 40576 24799 24802 40583 40581 24733 40823 24783 24775 40578 24828 24830 24833 25005 25007 25009 25011 12 12/60 12/60 12/60 12 12 12 4509Y 4510 4511 4515 4516 4519 4522 PAR36 PAR36 PAR36 PAR36 PAR36 PAR36 PAR46 Special Service Tractor Flood, Emergency Tractor Spotlamp Spotlamp Marine Aircraft Landing 12 12 12 4530 4531 4532 PAR46 PAR46 PAR46 Signal, Flashing Auto Headlamp, Military Aircraft 12/24 12 12/24 12 12 12 12 12/60 12/60 12 12 12 12 12 12 12 4535 4537 4537-2 4537X 4541 4543 4545 4546 4546-1 4547 4551 4552 4553 4554 4555 4557 PAR46 PAR46 PAR46 PAR46 PAR56 PAR56 PAR56 PAR36 PAR36 PAR36 PAR46 PAR64 PAR46 PAR46 PAR64 PAR64 12 12 12 12 12/24 12/24 4559 4570 4571 4572 4578 4579 PAR64 PAR46 PAR46 PAR46 PAR46 PAR46 4580 4581 4582 4587 4589 4589-1 4591 4593 4594 4595 4596 4626 4627 4635 4636-3 PAR46 PAR46 PAR46 PAR36 PAR36 PAR36 PAR36 PAR36 PAR36 PAR36 PAR36 PAR36 PAR36 PAR46 PAR46 24859 12 24862 12 24853 12 24867 12 24873 24871 12/60 23509 60 24882 12 24887 12 24891 12 24892 12 24898 12 24964 12 24966 12 33284 12 19632 16407 12/672 13.0 6.4 6.2 6.4 6.2 13.0 13.0 26.0 12.5 28.0 28.0 Spotlamp 6.4 Aircraft Landing 13.0 Spotlamp 13.0 Marine Spotlamp 13.0 Aircraft Landing 28.0 Marine Spotlamp 12.5 Marine Searchlight 12.0 Hand Lantern 4.7 Hand Lantern 4.7 Hand Lantern 4.75 Aircraft Taxiing 28.0 Aircraft Landing 28.0 Aircraft Landing 28.0 Aircraft Taxiing 28.0 Aircraft Landing 115.0 Aircraft Landing/Taxiing 28.0 28.0 Aircraft Landing 28.0 Aircraft Taxiing 28.0 Flood, Special Service 28.0 Auto Flood, Military 28.0 C.I.M. Flood 28.0 C.I.M. Headlamp 28.0 28.0 Aircraft Landing 28.0 Aircraft Landing 28.0 Aircraft/Helicopter Flood 28.0 Aircraft Taxiing 28.0 Aircraft Cockpit Flood, C.I.M. 28.0 Aircraft Cockpit Flood, C.I.M. 28.0 Aircraft Landing 28.0 Aircraft In-Air Refueling 28.0 Aircraft Navigation 28.0 Aircraft Navigation 28.0 Aircraft Landing 28.0 Aircraft Taxiing 28.0 Aircraft Flood 28.0 Aircraft Landing 16.5 Signal 14.0 100W – 25W 800 30W 2,300 30W 55,000 30W 45,000 100W 30,000 250W 290,000 5.3A 40W 250W 150W 30W 100W 100W 100W 450W 100W 100W .5A .5A 1.25A 250W 250W 250W 450W 1,000W 1,000W 400W 600W 150W 150W 150W 60W 80W 60W 450W 450W 450W 250W 50W 50W 100W 50W 100W 100W 250W 150W 100W 450W 80W 100,000 30,000 75M 14,500 95,000 200,000 200,000 200,000 470,000 250,000 225,000 6,300 6,300 20,000 75,000 500,000 300,000 90,000 600,000 540M 100M 600,000 32,000 7,000 4,500 1,600 24M 11M 400,000 400,000 20,000 40,000 5,000 5,000 90,000 1,500 70,000 60,000 150,000 25,000 3,000 325,000 90,000 Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals 2.75 2.75 2.75 2.75 2.75 2.75 3.13 25 300 300 100 300 25 25 12 6 20 80 Trapezoidal 5 5 9 4 40 7 12 10 Screw Terminals Screw Terminals Screw Terminals 3.75 3.75 3.75 Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Slip-on Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals 3 Screw Terminals 3.75 3.13 3.13 3.13 4.5 4.5 4.5 2.75 2.75 2.75 3.75 3.75 3.13 3.13 3.75 3.75 Screw Terminals Screw Terminals Screw Terminals Screw Terminals 2 Contact Lugs 3 Contact Lugs 3.75 3.75 3.75 3.75 4 4 Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Slip-on Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Combination 3.75 3.13 3.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 3.75 3.75 50 400 100 100 100 25 25 25 25 50 100 100 100 100 25 25 25 25 25 25 100 25 300 300 300 800 400 400 10 10 10 25 400 400 25 400 300 300 25 300 300 25 200 11 11 20 5 12 19 16 19 51⁄2 4 11 6 11 6 11 6 15 11 9 5 9 5 3 3 3 3 3 3 50 10 7 8 11 12 50 16 20 11 11 15 25 11 11 12 50 9 80 25 55 55 55 30 25 25 7 7 13 14 13 14 50 55 40 13 Trapezoidal Trapezoidal 12 6 80 30 13 7 14 6 11 12 40 9 80 30 14 15 9 71⁄2 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. 23 167 92, 138, 167 167 167 167 167, 302 167 138 138, 167 138, 167 302 138, 302 138, 302 138, 167 302 302 302 302 302 302 7-17 Miniature & Sealed Beam Lamps Order Code Case Qty. GE Unit Bulk Unit/Bulk Lamp No. Bulb Primary Application Design Volts Design Watts MBCP Base MOL Rated (in) Life (hrs) Spread to 10% MBCP Warning Horiz Vert & Footnotes SEALED BEAM (CONTINUED) 18517 41861 18518 6/576 6 4651 4652 165mm Headlamp, High Beam, 1A1 12.8 50W SAE 165mm Headlamp, Low Beam, 2A1 12.8 40W SAE 12.8 60W 39906 39907 12/60 4700 PAR36 Spot/Flood 113.0 100W 100M 13.0 100W 50M 45427 12 4713 PAR36 Aircraft Logo 28.0 150W 4,200 44724 12 4752 PAR36 C.I.M. Flood 28.0 60W 2,000 24973 12 4800 PAR56 Auto Headlamp, Military 28.0 50W SAE 28.0 40W 24980 12 4811 PAR36 Auto Headlamp, Military 28.0 110W SAE 28.0 55W 24981 24982 12/60 4825R PAR36 C.I.M. Stop/Tail Red Lens 28.0 50W 200 28.0 18W 40 24995 12 4880 PAR46 C.I.M. Headlamp 28.0 60W 6,000 45110 45111 12/576 4912-1 165mm Auto/Truck Fog 12.8 50W 14,000 45113 16 4913-1 165mm Farm Tractor, Flood 12.8 50W 1,350 45116 16195 12/576 4921-1 165mm Auto/Truck, Special Service 13.0 100W 25,000 11639 6 5001 PAR46 Headlamp, High Beam. 1C1 12.8 50W SAE 16152 12 5557 PAR64 Aircraft Landing/Taxiing 28.0 1,000W 540M 28.0 400W 100M 25114 12 6006 PAR56 Auto Headlamp 6.1 50W SAE 6.2 40W 18519 6 6014 PAR56 Auto Headlamp, Type 2D1 12.8 60W SAE 12.8 50W 38416 38607 12/432 6015 PAR56 Headlamp, Type 2D1 12.8 50W SAE 12.8 50W 25153 12 6045 PAR56 Signal 26.0 170W 230,000 18521 43867 6/448 6052 40190 40191 42385 39987 39988 41865 41866 45101 45102 11421 11422 22386 10211 22387 18350 15129 17674 12/60 60 12/60 12/60 12/60 12/60 6 6 6 48 12 60 7400 PAR36 7400-1 PAR36 7414Y PAR36 7613 PAR36 7613-1 PAR36 7672-1 PAR36 H4351 140mm H4351LH 140mm H4352 140mm H4360 140mm H4405 PAR36 H4460X PAR36 15133 18532 45027 46375 12 6/576 6 H4515 PAR36 H4651 165mm H4651SB 165mm 18533 49810 6/576 H4656 200mm Auto Headlamp, Type 2B1 165mm 14753 6 H4656H0 165mm 45475 6 H4656SB 165mm 7-18 2 Contact Lugs 3 Contact Lugs 4.8 4.8 3 Screw Terminals 2.75 Screw Terminals Screw Terminals 3 Contact Lugs 2.75 2.75 5 3 Contact Lugs 3 3 Screw Terminals 2.75 2 Contact Lugs Slip-on Terminals Slip-on Terminals Slip-on Terminals 2 Contact Lugs 3 Screw Terminals 4 4.53 4.53 4.53 4 3.75 3 Contact Lugs 5 3 Contact Lugs 5 3 Contact Lugs 5 Screw Terminals 12.8 65W SAE 3 Contact Lugs 12.8 55W Signal, Rotating Beacon 12.8 35W 33,000 Slip-on Terminals Signal, Rotating Beacon 12.8 35W 33,000 Screw Terminals Signal, Light Yellow Lens 12.8 18W 1,000 Screw Terminals Emergency Bldg. Lighting 6.0 8W 400 Screw Terminals Emergency Bldg. Lighting 6.0 8W 400 Slip-on Terminals Emergency Bldg. Lighting 6.0 7.2W 350 Slip-on Terminals Headlamp Low Beam Type K 12.8 55W SAE Right Angle Auto – Left Drive – Export only 12.8 55W – Right Angle Headlamp,Upper Beam,Type K 12.8 65W SAE Right Angle Tractor 12.8 37.5W 2,000 2 Right Angle Lugs Spotlamp, Shielded Bulb 12.8 30W 66,000 Screw Terminals Tractor 12.8 40W 11,000 3 Screw Terminals 12.8 40W 8,500 Spotlamp, Shielded Bulb 6.4 30W 67,000 Screw Terminals Headlamp,High Beam,Type 1A 12.8 50W SAE 2 Contact Lugs Headlamp, High. 1A. 12.8 50W SAE 2 Contact Lugs White Light Headlamp, Low Beam, 2A1 12.8 35W SAE 3 Contact Lugs 12.8 35W Headlamp, Low 2A1. 12.8 40W SAE 3 Contact Lugs High output 12.8 55W Headlamp, Low 2A1. 12.8 40W SAE 3 Contact Lugs White Light 12.8 55W 4.5 5.44 2.75 2.75 2.75 2.75 2.75 2.75 4 4 4 3 2.75 2.75 2.75 4.8 4.8 4.8 4.8 4.8 200 200 320 25 255 300 800 400 400 400 400 200 200 800 300 400 300 300 50 100 300 500 320 150 300 500 100 150 320 300 300 300 50 50 50 500 500 150 320 100 320 320 100 200 200 200 320 200 700 75 200 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. 4, 307 4, 307 12 17 50 50 7 18 65 25 - - 40 80 40 7 20 7 11 25 15 11 167, 307 4, 307 109, 307 4 138, 302 4 4 9 8 4, 307 12 12 50 30 30 30 5 5 25 20 20 20 Trapezoidal 7 4 22 10 22 13 5.5 4 307 307 307 307 167, 307 4, 307 167, 307 4, 307 4, 307 4, 307 4, 307 4, 307 Miniature & Sealed Beam Lamps Order Code Case Qty. GE Unit Bulk Unit/Bulk Lamp No. Bulb Primary Application Design Volts Design Watts 12.8 12.8 12.8 65W 55W 65W SAE 3 Contact Lugs 4.8 SAE 2 Lugs 12.8 55W SAE 2 Lugs 12.8 50W 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 6.0 6.0 6.0 6.0 6.0 6.0 12.0 6.0 12.0 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 13.0 MBCP Base MOL Rated (in) Life (hrs) Spread to 10% MBCP Warning Horiz Vert & Footnotes SEALED BEAM (CONTINUED) 18535 22879 6/576 H4666 18536 48533 6/480 H4701 18538 48534 6/480 H4703 18522 6 H5001 18523 6 H5006 19428 19559 6/432 H5024 19411 19556 6/576 H5051 19429 19558 6/448 H5054 165mm Headlamp, High. 1A. Long Life 200mm Headlamp. High/Low. 2B1. 19412 19557 6/576 H5062 165mm Headlamp, High/Low. 2A1. 48 6 H5360 H6024 41453 18525 18534 11545 6/448 14752 6 45477 6 43561 43562 23541 43564 43565 43567 43570 43571 43574 44642 44643 44924 44925 12720 12721 42841 42842 43576 43577 14616 43580 17672 14617 43583 14618 43586 49695 49731 49732 42838 42839 14619 43589 45058 43591 43592 18022 17894 17890 12/60 60 12/60 12 12/60 60 12/60 12/60 12/60 12/60 12/60 6/60 60 6/24 6/60 12 12/60 12/60 6/24 24 12/24 24 12/24 26694 26695 12/24 165mm Headlamp, High/Low Beam, 2E1 150mm Headlamp High Beam Type UF 150mm Headlamp, Low Beam Type LF PAR46 Headlamp High Beam, Type 1C1 PAR46 Headlamp, Low Beam Type 2C1 PAR56 Headlamp. High/Low. 2D1. 140mm Halogen Tractor Work Light PAR56 Headlamp, High/Low Beam, 2D1 H6054 200mm Headlamp, High/Low Beam, 2B1 H6054HO 200mm Headlamp, 2B1. High Output. H6054SB 200mm Headlamp, 2B1. White Light H7550 PAR36 Hand Lantern H7550-1 PAR36 Hand Lantern H7551 PAR36 Emergency Bldg. Lighting H7552 PAR36 Emergency Bldg. Lighting H7553 PAR36 Emergency Bldg. Lighting H7554 PAR36 Emergency Bldg. Lighting H7555 PAR36 Emergency Bldg. Lighting H7556 PAR36 Emergency Bldg. Lighting H7557 PAR36 Emergency Bldg. Lighting H7600 PAR36 Signal, Rotating Beacon H7604 PAR36 Halogen Spotlamp H7606 PAR36 Tractor, Flood H7607 PAR36 Tractor Flood H7609 PAR46 Tractor Flood H7610 PAR36 Halogen Tractor H7612 PAR46 Halogen Fog H7614 PAR36 Halogen Flood H7616 PAR36 Halogen Spotlamp H7619 PAR46 Halogen Tractor H7621-1 PAR46 Auto/Truck Special Service H7635 PAR46 Halogen Spotlamp H7635X PAR46 Halogen Spotlamp H7680 PAR46 Infrared Spotlamp HIR H7680X PAR46 Infrared-Spotlamp 13.0 HIR Long Life 4, 166, 307 3.4 150 320 150 3.4 320 307 SAE 2 Contact Lugs 4 200 4, 307 35W 35W 65W 42W 50W SAE 3 Contact Lugs 4 200 320 5 400 2000 4.8 500 4, 307 65W 42W 40W 55W 37.5W 65W 35W 65W 35W 65W 55W 65W 55W 8W 8W 8W 10W 12W 20W 8W 6W 12W 37.5W 50W 50W 65W 50W 50W 37.5W 50W 37.5W 50W 50W 50W 50W 80W SAE 3 Contact Lugs 5.44 SAE 3 Contact Lugs 4.8 SAE 3 Contact Lugs SAE 2 Contact Lugs Screw Terminals Slip-on Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Slip-on Terminals Screw Terminals Screw Terminals Screw Terminals 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 3.75 2.75 3.75 2.75 2.75 3.75 3.75 3.75 3.75 3.75 400 2000 400 2000 900 150 320 150 320 150 700 75 200 50 50 50 50 50 50 50 50 50 300 100 400 600 400 400 450 100 300 400 200 100 100 100 80W 230,000 Screw Terminals 3.75 300 2,000 2 Right Angle Lugs SAE 3 Contact Lugs 3 5 SAE 3 Contact Lugs 5.44 SAE 3 Contact Lugs 5.44 SAE 3 Contact Lugs 5.44 25,000 25,000 550 650 850 1,400 550 400 850 60,000 100,000 1,000 1,500 2,200 5,200 15,000 2,000 70,000 6,000 20,000 160,000 160,000 275,000 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. 307 4, 307 4, 307 4, 307 4, 307 Trapezoidal 307 4, 307 4, 307 4, 307 4, 307 3 3 3 3 30 20 30 20 30 20 30 20 30 20 30 20 30 20 9 41⁄2 7 5 80 30 Non-Symmetrical 80 20 Trapezoidal 40 7 70 30 7 4 Trapezoidal 50 7 4 61⁄2 4 61⁄2 61⁄2 61⁄2 61⁄2 61⁄2 307 307 307 307 307 307 307 307 307 307 307 4, 307 4, 307 4, 307 4, 307 307 307 307 4, 307 4, 109, 307 307 167, 307 301 301 7-19 Miniature & Sealed Beam Lamps Order Code Case Qty. GE Unit Bulk Unit/Bulk Lamp No. Bulb Primary Application Design Volts Design Watts 12.8 65W 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 13.0 28.0 28.0 28.0 28.0 28.0 28.0 13.0 50W 50W 50W 50W 50W 50W 37.5W 37.5W 50W 50W 100W 450W 600W 600W 450W 450W 600W 250W 13.0 28.0 28.0 28.0 12.0 12.0 12.0 12.0 250W 75,000 Screw Terminals 450W 310,000 Screw Terminals 250W 60,000 Screw Terminals 600W 650,000 Screw Terminals 20W 365 Screw Terminals 20W 120 Screw Terminals 20W 1,900 Screw Terminals 20W 11,000 Screw Terminals MBCP Base MOL Rated (in) Life (hrs) Spread to 10% MBCP Warning Horiz Vert & Footnotes SEALED BEAM (CONTINUED) 23250 13426 14892 15763 15768 15770 15772 16484 16483 17988 16976 16978 16482 16204 22109 37706 40579 42552 41097 37372 40577 34537 16 6/16 12/48 12/48 12/48 48 12/48 12 12/48 12/48 12 12 12 12 12 12 12 12 H7913 HIR H7921-1 H7935-1 H9405 H9406 H9411 H9414 H9415 H9415A H9420 H9421 Q4509 Q4554 Q4559 Q4559X Q4566 Q4597 Q4629 Q4631 39112 36271 41452 16784 29130 22227 28113 28111 28874 12 12 12 12 12/60 12 12 12 Q4632 Q4681 Q5551 Q5559 Q7558 Q7559 Q7560 Q7561 47460 15767 15769 15771 7-20 16 165mm Farm Tractor, Flood Infrared 165mm Auto/Truck Special Service 165mm Halogen Spotlamp 150mm Spotlamp, Halogen 150mm Tractor, Flood, Halogen 150mm Tractor, Trapezoidal 150mm Tractor Medium Flood 150mm Auto, Fog 150mm Auto Fog Amber 150mm Auto, Driving 150mm Auto, Truck, Special Service PAR36 Aircraft Landing PAR46 Aircraft Taxiing PAR64 Aircraft Landing PAR64 Aircraft Landing PAR46 Aircraft Logo Light PAR46 Aircraft Flood PAR64 Aircraft Logo Light PAR36 Aircraft Landing, Wing Inspection PAR36 Aircraft Logo PAR46 Aircraft Landing PAR46 Aircraft Taxiing PAR64 Aircraft Landing PAR36 Landscaping PAR36 Landscaping PAR36 Landscaping PAR36 Landscaping 4,000 2 Contact Lugs 23,900 175,000 100,000 1,350 5,400 2,700 12,000 – 47,000 4,000 140,000 65,000 600,000 765,000 150,000 16,000 20,000 80,000 Slip-on Terminals Slip-on Terminals 2 Right Angle Lugs 2 Right Angle Lugs 2 Right Angle Lugs 2 Right Angle Lugs 2 Right Angle Lugs 2 Right Angle Lugs 2 Right Angle Lugs 2 Right Angle Lugs Screw Terminal Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals Screw Terminals 4.8 800 4.53 200 4.53 100 3 100 3 400 3 400 3 400 3 200 3 200 3 200 3 200 2.75 100 2.63 100 3.75 100 3.75 100 3.32 1,000 3.32 1,000 4.81 1000 2.75 500 2.75 2.63 3.32 3.75 2.75 2.75 2.75 2.75 500 50 100 200 5000 5000 5000 5000 For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. 70 20 35 5 31⁄2 61⁄2 7 4 70 30 Trapezoidal 45 20 45 5 45 5 15 5 45 8 7 7 50 11 12 8 11 71⁄2 16 12 60 35 55 35 13 12 14 15 48 11 55 70 24 9 12 9 12 71⁄2 45 70 23 8 301 4, 109, 307 307 307 4, 307 4, 307 4, 307 4, 307 4, 307 4, 307 4, 109, 307 301 301 138, 301 139, 301 301 301 301 301 301 301 301 138, 301 301 301 301 301 Miniature & Sealed Beam Lamps FOOTNOTES # Footnote 1 2 3 4 10 11 12 13 14 15 17 23 32 33 44 68 69 70 75 78 79 80 92 109 110 113 Special ballast required per ECE R99. B3 life, not average life. Useful life hours. Life at 14 volts. Life at 5 volts. Filament vertical. Average overall length. Filament supported. This lamp may not be suitable for some uses because of its excessive wattage requirements for the bulb size. This lamp may not be suitable for some uses because of its limited mechanical strength. Filament shielded. Life at 7 volts. Designed and rated for operation in supplementary cathode preheat circuits. Connections of major and minor filament to base are reversed from those for automotive lamps with Double Contact Index bases. Burn base down to horizontal. Life at 6.6 volts. Uses lens-end TL31⁄4 bulb. Provides 7,000 to 11,000 foot-candles in a 1⁄4" diameter spot at 1⁄8" from end of bulb. Not recommended for new OEM applications - suggested for new design are wedge base. These lamps produce a random flashing indication only. The majority should flash between 40-160 flashes per minute at normal room temperature, some will be outside this range. As ambient temperature and/or input voltage changes, the flash rate may vary considerably. At rated voltage and room temperature most lamps will flash within 60 seconds. Life estimated. Based on limited test information. ANSI specifies .38" LCL and .63" MOL. Life shown is AC voltage only. DC life will be approx. 50% of AC. Light output is approx. end foot candles, not spherical MSCP. Filament segments parallel. Special fixture required for highway use. To be used with variable load flasher in applications where bulb outage indication is not required, or with an appropriate fixed load flasher. Flash rate may be altered if used with incorrect fixed load flasher. This is a flange seal wire terminal lamp. When unbased lamps such as these are handled and wired into a device, damage can be kept to a minimum by allowing sufficient clearance so that no physical strain or excessive heat is placed on the exhaust tube, exhaust tube tip, or glass seal; by taking care in mounting lamp in equipment so that any material touching the glass is compatible in thermal expansion; and by avoiding excessive tensile strain on the lead wires. 116 Life tests are performed on DC voltage only. 121 To minimize the possible adverse effects on lamp life due to excessive wattage in relationship to bulb size: Burn Base Down to Base 45° Above Horizontal. Regardless of burning position, this excessive wattage will abnormally decrease light output during lamp life. 122 This is a wire terminal lamp. The glass-to-metal seal (and tip where applicable) are susceptible to damage by thermal shock, and soldering or welding within 1⁄8" of the glass should be avoided as glass cracks and air leaks may develop. Solderability may be adversely affected by storage for an extended period in excess of six months or by storage in a high humidity environment. Lamps with tinned leads would be subject to these storage restrictions. Nickel-plated leads are not recommended for soldering; however, their ability to be welded is not affected by these storage restrictions. 124 .028" metal pins spaced 44mm (.157") apart. GE’s two-pin lamps might not be compatible with all G-4 sockets since many sockets do not provide clearance for the exhaust tip. 127 LCL measured to top of filament. 128 Output is minimum 1⁄4" spot at .100" from bulb top. 130 Subminiature wedge base lamps under 12 volts have copper-clad outer lead wires to decrease contact resistance at the expense of corrosion resistance in severe environments. 132 Paint may peel, craze or discolor when subjected to excessive moisture, heat, and freezing in housings with plugged drain holes or which otherwise leak or trap moisture. 138 Life Test Conditions: Cycled 5 minutes on, 5 off. 139 Life Test Conditions: Cycled 20 minutes on, 20 off. 147 Differs from ANSI. 160 Filament will generate specified MSCP in a non shielded bulb. 161 MSCP measured with black top. 162 Life based on three hours of burning per start. MSCP at 100 Hrs. Designed and rated for operation in supplementary cathode preheat circuits. Use these lamps with auxiliary equipment specially designed to produce proper electrical values according to established specification. For total load, add auxiliary watts to lamp watts. 164 Life to approximately 50% of initial output. Values shown apply to use on AC unless otherwise shown. Life on DC is approximately 60% of AC values when DC current is equal to R.M.S. (Root Mean Square) AC value. When equal DC and R.M.S. AC voltages and equal resistances are utilized, life will be approximately the same. 166 Contact Lugs are angled. 167 Filament shielded. WARNINGS AND CAUTION NOTICES 301 303 WARNING Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass bulb is broken. Remove and dispose of lamp. Pressurized lamp–unexpected rupture may cause injury, fire, or property damage • Use in enclosed fixture rated for this product • Do not use lamp if outer glass is scratched or broken CAUTION Risk of burn • Allow lamp/fixture to cool before handling Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container WARNING Lamp may shatter if used in wrong circuit • Do not use in 110-120 Volt household circuit 302 WARNING Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product Unexpected lamp rupture may cause injury, fire, or property damage • Avoid contact with glass during operation • Avoid direct water/liquid contact • Use in enclosed fixture rated for this product 304 WARNING Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product Lamp emits UV radiation which may cause eye/skin injury • Avoid exposure of eyes and skin to unshielded lamp Pressurized lamp–unexpected rupture may cause injury, fire, or property damage • Use eye protection when handling lamp • Do not exceed rated voltage • Do not touch glass with bare hands • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not turn on lamp until fully installed • Keep away from children • Use protective screen when handling CAUTION Risk of burn • Allow lamp/fixture to cool before handling FOR BEST PERFORMANCE • Limit seal temperature to 350°C • Maintain 250°C minimum bulb wall temperature • Remove fingerprints from bulb with grease-free solvent • Operate at design voltage For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. 7-21 Miniature & Sealed Beam Lamps WARNINGS AND CAUTION NOTICES (CONTINUED) 305 309 CAUTION Lamp may shatter and cause injury if broken • Do not use excessive force when installing lamp WARNING Risk of electric shock • Turn power off before inspection, installation or removal CAUTION Lamp may shatter and cause injury if broken • Wear safety glasses and gloves when handling lamp • Do not use excessive force when installing lamp 306 WARNING Pressurized lamp–unexpected rupture may cause injury, fire, or property damage • Use eye protection when handling lamp • Do not exceed rated voltage • Avoid direct water/liquid contact • Use in enclosed fixture rated for this product • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not turn on lamp until fully installed • Keep away from children • Use protective screen when handling CAUTION Risk of burn • Allow lamp/fixture to cool before handling 307 WARNING Pressurized lamp–unexpected rupture may cause injury, fire, or property damage • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container 308 WARNING Risk of fire • Keep combustible materials away from lamp • Use in fixture rated for this product Pressurized lamp–unexpected rupture may cause injury, fire, or property damage • Use eye protection when handling lamp • Do not exceed rated voltage • Do not touch glass with bare hands • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Do not turn on lamp until fully installed • Keep away from children • Use protective screen when handling CAUTION Risk of burn • Allow lamp/fixture to cool before handling FOR BEST PERFORMANCE • Limit seal temperature to 350°C • Maintain 250°C minimum bulb wall temperature • Remove fingerprints from bulb with grease-free solvent • Operate at design voltage 7-22 310 WARNING Risk of electric shock • Turn power off before inspection, installation or removal Risk of fire • Use in fixture rated for this product A damaged lamp emits UV radiation which may cause eye/skin injury • Turn power off if glass bulb is broken. Remove and dispose of lamp. Pressurized lamp—unexpected rupture may cause injury, fire, or property damage • Use eye protection when handling lamp • Do not exceed rated voltage • Do not touch glass with bare hands • Avoid direct water/liquid contact • Use in enclosed fixture rated for this product • Do not use lamp if outer glass is scratched or broken • Use only properly rated ballast • Operate lamp only in specified position • Do not use beyond rated life • Do not turn on lamp until fully installed CAUTION Risk of burn • Allow lamp to cool before handling • Do not turn on lamp until fully installed • Turn power off before installing lamp Lamp may rupture if used on wrong ballast • Use only properly rated ballast Lamp may shatter and cause injury if broken • Wear safety glasses and gloves when handling lamp • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in a closed container • Remove and install by grasping only plastic portion of the lamp • Do not use excessive force when installing lamp INSTRUCTIONS FDA Warning WARNING - This lamp can cause serious skin burn and eye inflammation from short-wave ultraviolet radiation if outer envelope of the lamp is broken or punctured and the arc tube continues to operate. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain types of lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available. 21 CFR 1040.30. Hg - LAMP CONTAINS MERCURY Manage in Accord with Disposal Laws See: www.lamprecycle.org or 1-800-435-4448 Lamp should be installed by an automotive service specialist. For the most up-to-date product information, see www.gelighting.com. To convert inches to millimeters, multiply by 25.4. Projection Lamps GENERAL INFORMATION Lamp Locator ........................................................................................................................ 8-2 Base Identification ............................................................................................................... 8-3 Light Center Length .............................................................................................................. 8-3 Filament Identification ...................................................................................................... 8-4 Introduction ........................................................................................................................... 8-4 General Information .......................................................................................................... 8-5 ANSI-Coded GE Projection Lamps Index .................................................................. 8-6 QUARTZLINE® MULTI-MIRROR® REFLECTORS MR-11 Faceted Dichroic Reflector. Table 1 ................................................................ 8-9 MR-13 Faceted Dichroic Reflector. Table 2 ................................................................ 8-9 MR-16 Faceted Dichroic Reflector. Table 3 ................................................................ 8-9 QUARTZLINE® REFLECTOR LAMPS MR-16 Smooth Dichroic Reflector. Table 4 ..............................................................8-10 MR-14 or MR-16 Dichroic Reflector. 2-Pin Vented Base. Table 5...................8-10 QUARTZLINE® SINGLE-ENDED 4-Pin Slide Projection. Table 6........................................................................................8-10 Applications: Projection, Microfilm, Studio, Etc. Table 7.....................................8-10 Quartzline® Single-Ended – Amp Rated. Table 8...................................................8-11 QUARTZLINE® DOUBLE-ENDED PROJECTION. TABLE 9 ......8-11 INCANDESCENT PROJECTION 4-Pin Base. Table 10 ...........................................................................................................8-11 4-Pin Base – Proximity Reflector. Table 11...............................................................8-11 4-Pin Base – Focusing Reflector. Table 12 ...............................................................8-11 Medium Prefocus Base: P28/25. Table 13................................................................8-12 Single Contact Bayonet Base: Ba15s. Table 14 .....................................................8-12 Double Contact Bayonet Base: Ba15d. Table 15 ..................................................8-12 Single Contact Prefocus Base: P30s. Table 16 .......................................................8-12 Miscellaneous. Table 17 ...................................................................................................8-12 PHOTOFLOOD Standard. Table 18. .............................................................................................................8-12 Reflector. Table 19 ...............................................................................................................8-13 Enlarger & Printer. Table 20 ............................................................................................8-13 Pulsed Xenon Arc, Gemini®, And MARC™. Table 21 ..............................................8-13 For the most up-to-date product information, see www.gelighting.com. All footnote references found at the end of this section (page 8-13). To convert inches to millimeters, multiply by 25.4. 8-1 Projection Lamps LAMP LOCATOR Mini Multi-Mirror ® Multi-Mirror ® Reflector 2-Pin-Vented Base Reflector 4-Pin Base CBA DAT / DAK DAY / DAK 4-Pin Base BCK Incandescent Projection Lamps / 4-Pin Base Quartzline® Projection Lamps DEK / DFW / DHN CAR CZA / CZB CZX / DAB Incandescent Projection Lamps / 4-Pin Base – Proximity Reflector BLX BLC BNF CDD BAH BBA BCA ECA CBX/CBS G-6 G5.3 G-7 GZ9.5 G-7 2 Button T-4 GY6.35 Quartzline® Projection Lamps – Single-Ended 8-2 T-4 GZ9.5 DRB DRS DRC Incandescent Projection Lamps / Medium Prefocus Base EXV EXX EZK EBW ECT Standard Photofloods Incandescent Projection Lamps / Single or Double Contact Bayonet Base DDB DXC EAL Double-Ended Quartzline® Projection Lamps Reflector Photofloods DFN / DFC/ DCH / DJA / DFP DLD / DFZ GX17q DJL G17q Incandescent Projection Lamps / 4-Pin Base – Focusing Reflector For the most up-to-date product information, see www.gelighting.com. All footnote references found at the end of this section (page 8-13). To convert inches to millimeters, multiply by 25.4. DPT Mog Base Incandescent Projection Lamps / Misc. Projection Lamps PXA-50 PXA-80 Gemini® 300 EZG Pulsed Xenon Arc Lamps High-Intensity Gemini® Arc Lamps DDF EJL ELC ELH ENH ESD ESJ EVW EYA EJV MARC 350 / 16T EZT EZF/EZJ High-Intensity MARC™ Arc Lamps PH/211 PH/212 PH/213 BBA PH/140 PH/111A FAL FFJ Enlarger & Printer Lamps BASE IDENTIFICATION Typical bases used on Projection lamps in this catalog are shown below along with their names and common abbreviations. Where the base is an ANSI standard type, the ANSI reference code (which is the same as the IEC base code) is also shown. ANSI reference codes conform to American National Standard C81.10. C81.30. C81.50 specifications for electric lamp bases and lampholders. Illustrations are not to scale. Candelabra (Cand.) E12/15 Recessed Single Contact R7 Double Contact Bayonet (D.C. Bay.) BA15d Glass 2-Pin G6.35 (.040” diam. Pins) GY6.35 (.050” diam. Pins) GZ6.35 (Reflector Quartzline® lamps) Single Contact Bayonet (S.C. Bay.) BA15s Candelabra Prefocus (S.C. Pref.) P30s (D.C. Pref.) P30d Miniature 2-Pin G5.3 GY5.3 2-Pin (Flat Pins) Medium E26s Medium Prefocus P28/25 GX5.3 2-Pin (Round Pins) 2-Button 4-Pin G17q (Std. Volts) GX17q (Low Volts) Mogul E39 2-Pin Prefocus GY & GZ9.5 2-Pin Vented G7.9 (Std. Volts) GX7.9 (Low Volts) LIGHT CENTER LENGTH (LCL) Light center length is the distance from the center of the light source to the point indicated below for the lamp base used. It is a measurement to which the lamp is designed and is subject to the manufacturer’s tolerances. Base Type All Screw Bases Medium Prefocus S.C. or D.C. Bayonet 2-Pin Prefocus Miniature 2-Pin Glass 2-Pin LCL Reference Bottom base contact Top of base fins Top of base pins Bottom of base ceramic Bottom of base pins Bottom of base pins Base Type 2-Button 2-Pin Vented 4-Pin Locking 4-Pin S.C. , or D.C. Candelabra Prefocus LCL Reference Top of ceramic base to top of filament coil Bottom of base ceramic to lamp optical axis Bottom edge of base cup Bottom edge of base cup Plane of locating bosses on prefocus collar For the most up-to-date product information, see www.gelighting.com. All footnote references found at the end of this section (page 8-13). To convert inches to millimeters, multiply by 25.4. 8-3 Projection Lamps FILAMENT IDENTIFICATION The configuration of the filament in all tungsten filament lamps (including Quartzline®) is identified by a prefix letter and a suffix number. The prefix letter indicates whether the filament wire is a single coil (C) or a coiled coil (CC). The suffix number indicates the form or arrangement of the filament coil or coils on its support structure. Illustrations are not to scale. C-2V CC2-V C-9 2C-8 2CC-8 C-13 C-13D C-6 Oval C-6 CC-6 C-8 CC-8 INTRODUCTION General Electric Projection Lamps are designed for a wide variety of applications... and now extending well beyond the original picture-taking and audio-visual projection uses into such fields as: fiber optical systems, graphic arts, video camera lights, airport runway markers, micrographics, photo printers and enlargers, medical/scientific instruments, and many others. The information contained in this section is designed to provide end-users, equipment manufacturers, and lamp distributors and dealers with: • Essential technical data on GE Projection Lamps (Quartzline®, Incandescent, MARC™ and Photoflood) • Suggested substitutes for improved performance or discontinued lamps The majority of Projection Lamps described herein are characterized by: • Precisely manufactured, tailored filaments… maximizing source brightness, optimum performance in precision optical devices • High light-generating efficacy (lumens per watt)… to help minimize power requirements and heat generation • Prefocus type bases, or rim-reference mounting for Multi-Mirror® lamps… to position the filament accurately in relation to the associated optics • Design life Rated Life (per ANSI Standard) • Lamps with internal or external reflectors (as in Multi-Mirror® and some 4-pin projection lamps)… permitting high-efficiency illumination system designs with a minimum of additional optical control elements Manufacturers and designers of equipment requiring lamps should select lamps of established design whenever possible for maximum economy, as well as for ease of replacement by their customers through regular trade channels. General Electric offers application engineering assistance to all customers for applying lamps in product design. Contact your local GE Lamp Representative for additional information or assistance. CAUTION NOTICE As with any product, certain precautions should be observed in the handling and use of GE Projection Lamps to provide optimum performance and safety. These are given in the Caution Notices that are printed on page 8-13. Important Notice This catalog contains accumulated data to March 2006. Additional information is constantly being uncovered through research and testing, which may modify the data given herein. This is particularly true of newer lamps. For the latest lamp design data and information, contact your General Electric Lamp Representative. The data and suggested applications contained in this catalog, as well as any additional information our representative may be able to furnish, are for general information only and are not intended and should not be taken as representations or warranties as to the suitability of a lamp for any particular 8-4 application or use in any particular equipment, nor are our representatives authorized to make any such representations or give any such warranties. Applications and conditions of use are many and varied, and beyond our control. We cannot possibly have the same degree of knowledge that the purchaser has with respect to the design of his equipment and the conditions of its use. Therefore, it is up to the purchaser to make his own determination as to the suitability of a lamp for his intended application or use and to assume the responsibility for that determination. General Electric desires to supply the best possible products at all times. For this reason, General Electric reserves the right to make changes in its products when it believes such charges will improve its products. For the most up-to-date product information, see www.gelighting.com. All footnote references found at the end of this section (page 8-13). To convert inches to millimeters, multiply by 25.4. Projection Lamps GENERAL INFORMATION General Electric Projection Lamps are briefly described in the alphabetical lamp index (pages 8-6 – 8-7). More extensive descriptive and performance data are found in the lamp tables, which are organized as “families” of lamps with one or more features in common – such as Multi-Mirror® Quartzline®, SingleEnded Quartzline®, 4-Pin Based Incandescent, Photoflood, etc. Within each table, lamps are listed alphabetically by GE Lamp Code. GE MULTI-MIRROR® QUARTZLINE® PROJECTION LAMPS Invented By GE For Optimized Projection System Performance. The Multi-Mirror® and its new companion, the Mini Multi-Mirror®, are reflector halogen Quartzline® lamps with innovative GE features that result in better system efficiency, screen uniformity, lamp-to-lamp consistency and relamping convenience. Feature • Dichroic reflector • Precise rim reference • Accurate snap-in alignment • Faceted reflector • Halogen Quartzline® lamp Benefit • Cool light beam • Efficient light reflection • Quick lamp installation • Efficient beam for brighter image • Uniform screen image • Precision beam control • Whiter and brighter light • No bulb blackening/blistering • Constant light output through life • Stable color temperature Applications • Slide Projection • Front/Rear Screen Projection • Microfilm • Overhead Projection • 16mm Movie • 8mm Movie • Film Strip • Enlargers/Printers • Fiber Optics • Medical/Scientific Instruments • Video Camera Lights • Airport Runways • Display Each GE Multi-Mirror® lamp type is optically tailored to its application. First, the appropriate type of multi-faceted reflector is determined. Then a filament tube developed, using advanced Quartzline® technology. Finally, the two are combined, using sophisticated, computerized precision-assembly techniques. The result – consistently high performance... lamp after lamp after lamp. For the most up-to-date product information, see www.gelighting.com. All footnote references found at the end of this section (page 8-13). To convert inches to millimeters, multiply by 25.4. 8-5 Projection Lamps Order Code Description Watts Bulb Volts Shape Base Table Page No. No. INDEX-ANSI CODED GE PROJECTION LAMPS BAB USE Q20MR16CG40BAB 10933 40886 40563 40564 36178 40658 BAB/PH BAH BBA BCA BCK BHB 20 300 250 250 500 250 12 115 118 118 120 120 MR16 A21 A21 A21 T6 MR14 GX5.3 2-Pin Medium Medium Medium G17q 4-Pin G7.9 2-Pin 3 18 18 18 6 5 9 12 12 12 10 10 BHC USE DYS/DYV/BHC 29140 30232 29156 32137 29604 18234 30421 29525 29380 29171 29169 BLC BLK BLX BNF BRH BRL BXB CAL CAR CAX CAX 30 30 50 75 1000 50 34 300 150 50 50 118 125 118 120 120 12 8.5 120 120 118 130 S11 S11 S11 S11 T5 T3.5 T8 T10 T10 T8 T8 D. C. Bay. Cand. D. C. Bay. D. C. Bay. R7s G6.35 2-Pin S. C. Pref. G17q 4-Pin G17q 4-Pin D. C. Bay. D. C. Bay. 15 18 15 15 9 7 16 11 11 15 15 12 12 12 12 11 10 12 11 11 12 12 118 120 118 118 120 120 T8 T8 T8 T8 T8 T10 D. C. Bay. S. C. Bay. D. C. Bay. D. C. Bay. S. C. Bay. G17q 4-Pin 15 14 15 15 14 11 12 12 12 12 12 11 120 T10 Med. Pref. 13 12 120 120 21 120 20 19 21 13.8 120 G17q 4-Pin G17q 4-Pin GX17q 4-Pin G17q 4-Pin GX5.3 2-Pin GX5.3 2-Pin GX5.3 2-Pin GX5.3 2-Pin G17q 4-Pin 10 10 12 12 3 3 3 3 11 11 11 11 11 9 9 9 9 11 GX17q 4-Pin G17q 4-Pin 12 12 11 11 CBS USE CBX/CBS 29208 29257 29266 29244 43330 29664 CBX/CBS CDD CDJ CEB CEM CZA/CZB 75 100 100 100 120 500 CZB USE CZA/CZB 29677 CZX/DAB 500 DAB USE CZX/DAB DAK USE DAT/DAK 40214 29695 29360 29364 43537 43206 43988 43950 29737 DAT/DAK DAY/DAK DCA DCH/DJA/DFP DDL DDM DDS DED DEK/DFW/DHN 400 500 150 150 150 80 80 85 500 T10 T10 T12 T12 MR16 MR16 MR16 MR16 T12 DFC USE DFN/DFC 36122 DFE 29386 DFN/DFC 80 150 30 T12 125 T12 DFP USE DHC/DJA/DFP DFW USE DEK/DFW/DHN DFZ USE DLD/DFZ 8-6 Order Code Description Watts Bulb Volts Shape Base Table Page No. No. INDEX-ANSI CODED GE PROJECTION LAMPS (CONTINUED) DHN USE DEK/DFW/DHN DHX USE DLS/DLG/DHX DJA USE DHC/DJA/DFP 29338 DJL 44854 DJT 40216 DLD/DFZ 150 50 80 120 T14 G17q 4-Pin 13.8 MR16 GX5.3 2-Pin 30 T14 GX17q 4-Pin 12 3 12 12 9 12 DLG USE DLS/DLG/DHX 29366 40161 39742 29959 29968 29947 30304 30151 30145 36952 36953 30364 32071 33248 33250 32955 DLS/DLG/DHX DNE DNF DPT DRB DRS DVY DXB DXC DXX DXX DYH DYP DYR DYR DYS/DYV/BHC 150 150 150 1000 1000 1000 650 500 500 800 800 600 600 650 650 600 22 120 21 120 118 120 120 120 120 230 240 120 120 220 240 120 T14 MR16 MR16 T20 T20 T20 G6 R40 R40 T4 T4 G7 G7 G7 G7 G7 GX17q 4-Pin G7.9 2-Pin GX7.9 2-Pin Mogul Med. Pref. Med. Pref. G5.3 2-Pin Medium Medium R7s R7s G5.3 2-Pin 2-Button GZ9.5 2-Pin Pf GZ9.5 2-Pin Pf GZ9.5 2-Pin Pf 12 5 5 17 13 13 7 19 19 9 9 7 7 7 7 7 12 10 10 12 12 12 10 13 13 11 11 10 10 10 10 10 G7 T3.5 T4 T6.4 R40 PS25 PS25 A23 PS25 MR16 MR16 MR16 MR16 T6 T4 MR16 MR16 MR16 GZ9.5 2-Pin Pf G5.3 2-Pin GZ9.5 2-Pin Pf D.C. Bay. Medium Medium Medium Medium Medium GZ6.35 2-Pin GZ6.35 2-Pin GZ6.35 2-Pin GZ6.35 2-Pin GZ9.5 2-Pin Pf G6.35 2-Pin GX5.3 2-Pin GX5.3 2-Pin GX5.3 2-Pin 7 7 7 15 19 18 18 18 18 3 3 3 3 7 7 4 3 3 10 10 10 12 13 12 12 12 12 9 9 9 9 10 10 10 9 9 4 4 3 10 10 9 DYV USE DYS/DYV/BHC 19479 37346 37695 30202 30281 40566 40567 40565 40568 21276 21277 21278 21279 37527 14874 32882 29150 29151 DYS-5 DZA DZE/FDS EAJ EAL EBV EBW PH/B2 ECA ECT EFM EFN EFP EFR EHA EHJ EJA EJL EJM 600 30 150 35/25 500 500 500 250 500 50 75 100 150 500 250 150 200 150 120 10.8 24 12 120 118 118 120 120 8 12 12 15 120 24 21 24 21 EJN USE ELD/EJN 32831 EJV 32886 EJY 35200 EKE 150 80 150 For the most up-to-date product information, see www.gelighting.com. All footnote references found at the end of this section (page 8-13). To convert inches to millimeters, multiply by 25.4. 21 MR16 GX5.3 2-Pin 19 MR16 GX5.3 2-Pin 21 MR16 GX5.3 2-Pin Projection Lamps Order Code Description Watts Bulb Volts Shape Base Table Page No. No. Order Code Description Watts Bulb Volts Shape Base Table Page No. No. INDEX-ANSI CODED GE PROJECTION LAMPS (CONTINUED) INDEX-ANSI CODED GE PROJECTION LAMPS (CONTINUED) 35800 EKP/ENA 41783 EZA/4 23071 EZC 15832 EZF/EZJ 80 30 MR16 GX5.3 2-Pin 3 9 GX5.3 2-Pin GX5.3 2-Pin GX5.3 2-Pin GX5.3 2-Pin GX5.3 2-Pin GX5.3 2-Pin GY5.3 2-Pin 3 3 3 3 3 3 3 9 9 9 9 9 9 9 18 MR14 GX7.9 2-Pin 24 T4 G5.3 2-Pin 24 MR14 GX7.9 2-Pin 5 7 5 10 10 10 EKS USE EMM/EKS 36899 36902 37462 15377 22023 38306 38476 EKX EKZ ELC ELC/500 ELC/C ELD/EJN ELH 200 30 250 250 250 150 300 24 10.8 24 24 24 21 120 MR16 MR16 MR16 MR16 MR16 MR16 MR16 ELR USE ELS/ELR 41885 ELS/ELR 42612 EML 40017 EMM/EKS 50 175 250 ENA USE EKP/ENA ENC USE ENW/ENC 38686 25475 40248 41705 19475 40598 41430 41729 41882 42614 41874 43756 11698 11322 38311 41164 10099 11110 11427 11478 11482 12092 12003 12095 11750 12097 12696 19322 13617 ENH ENL ENW/ENC ENX ENX-5 ENZ EPN EPT EPV EPX ERV ESD ESJ ETJ ETT EVD EVV EVW EWR EXL EXM EXR EXV EXW EXX EXY EYB EYB-5 EYH/FKT 250 50 80 360 360 50 35 42 90 90 340 150 85 250 1000 400 120 250 150 30 45 300 100 300 250 250 360 360 250 120 12 19 82 86 30 12 10.8 14.5 14.5 36 120 82 120 120 36 6.6A 82 6.6A 6.6A 6.6A 82 12 82 120 82 82 86 120 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 T5 T6 T4 MR16 T4 T3.5 T3.5 MR13 MR16 MR13 MR16 MR13 T3.5 T3.5 G6 GY5.3 2-Pin GX5.3 2-Pin GX5.3 2-Pin GY5.3 2-Pin GY5.3 2-Pin GX5.3 2-Pin GX5.3 2-Pin GX5.3 2-Pin GX5.3 2-Pin GX5.3 2-Pin GX5.3 2-Pin GY5.3 2-Pin GY5.3 2-Pin GY5.3 2-Pin R7s GY6.35 2-Pin GZ9.5 2-Pin GY5.3 2-Pin GZ9.5 2-Pin GZ9.5 2-Pin GZ9.5 2-Pin GX5.3 2-Pin GX5.3 2-Pin GX5.3 2-Pin GY5.3 2-Pin GX5.3 2-Pin G5.3 2-Pin G5.3 2-Pin G5.3 2-Pin 3 3 3 3 3 4 3 3 3 3 3 3 3 3 9 7 8 3 8 8 8 2 3 2 3 2 7 7 7 9 9 9 9 9 10 9 9 9 9 9 9 9 9 11 10 11 9 11 11 11 9 10 9 10 9 11 11 11 32 45 225 6.6A MR16 Wire Term. 6.6A MR16 GX5.3 2-Pin 68 MR13 GX5.3 2-Pin 3 3 2 10 10 9 120 MR16 GY5.3 2-Pin 6.6A T4 GZ9.5 2-Pin 120 T4 R7s 3 8 9 10 11 11 EZJ USE EZF/EZJ 15477 EZK 15243 EZL 29581 FAL 150 200 420 FBD USE FBG/FBD 33663 29598 14876 13598 FBG/FBD FCB FCR FCS 500 600 100 150 120 120 12 24 G6 T4 T3 T4 G5.3 2-Pin R7s GY6.35 2-Pin G6.35 2-Pin 7 9 7 7 11 11 11 11 12 24 120 120 82 13.8 T3 T4 T4 T4 MR13 MR16 GZ9.5 2-Pin Pf G6.35 2-Pin R7s R7s GX5.3 2-Pin GX5.3 2-Pin 7 7 9 9 2 3 11 11 11 11 9 10 12 13.8 24 13.8 24 82 120 35 45 125 120 120 120 120 MR11 MR11 T4 MR16 T4 MR16 T3.5 PAR20 PAR24 S11 S14 A21 A21 A21 T3 T3 GZ4 2-Pin GZ4 2-Pin GY6.35 Ceramic GX5.3 2-Pin G6.35 2-Pin GY5.3 2-Pin G5.3 Special 2-Pin Plug Special 2-Pin Plug S.C. Bay. Medium Medium Medium Medium WireTerm/Ceramic WireTerm/Ceramic 1 1 7 3 7 3 7 21 21 20 20 20 20 20 21 21 9 9 11 10 11 10 11 13 13 13 13 13 13 13 13 13 FDS USE DZE/FDS 35321 36878 29592 30276 47614 47914 FDT FDV FFJ FFM FHS FHX 100 150 600 420 300 25 FKT USE EYH/FKT 30894 25261 19886 14887 18241 21613 80853 11134 39936 30162 43220 40569 40570 40571 30124 30129 FLS 28 FLT 28 FLW 300 FML 50 FNT/100 275 FXL 410 GCA 250 GEMINI 300(EZG) 300 MARC 350-16T EZT 350 PH/111A 75 PH/140 75 PH/211 75 PH/212 150 PH/213 250 PXA 50 4000 PXA/80 8000 For the most up-to-date product information, see www.gelighting.com. All footnote references found at the end of this section (page 8-13). To convert inches to millimeters, multiply by 25.4. 8-7 Projection Lamps ANSI Codes These are 3-letter codes assigned by the American National Standards Institute. They provide a system of assuring mechanical and electrical interchangeability among similarly coded lamps from various manufacturers. General Electric uses the assigned ANSI Codes as Lamp Ordering Codes for most Projection Lamps. HEADINGS IN THIS CATALOG SECTION The following terms and descriptions can help you when checking Projection lamp specifications and when ordering products. Within each product line, lamps are divided into families. Within families, lamps are listed by ANSI code. Multiple-ANSI-Coded Projection Lamps Some GE Projection Lamps have an ordering code comprising two or more 3-letter ANSI codes – such as EM/EKS and DYS/DYV/BHC. The first code is the ANSI code, the secondary codes identify which the multiple-coded lamp can directly replace. Only the first code appears on the lamp itself. Multiple-coded lamps are so-designated by General Electric for the convenience of the customer. Maximum Overall Length (MOL) This dimension include the lamp bulb and all rigid parts of the base. Since the listed lengths include maximum tolerances, actual lamps are generally slightly shorter. Bulb Projection Lamp bulb designations use a combination of letters and numerals to indicate bulb shape and maximum diameter in eighths of an inch. For example: a “T12” bulb is Tubular-shaped and 12-eighths of an inch, or 1 1/2” in diameter. Illustrations of typical Projector Lamps and their respective bulb designations are shown in the tables of lamp families, pages 8-9 – 8-13. Base Projection Lamp base illustrations appear on page 8-3, along with their common trade names and abbreviations, plus their letter-number ANSI/IEC designations where applicable. Light Center Length (LCL) This dimension defines the location of the filament in relation to the base. It is measured from the geometric center of the filament to a specified point on, or plane through, the base. Light Center Length is subject to manufacturing tolerances. Reference points/planes from which LCL is measured are tabulated on page 8-3 for the various styles of lamp bases. Watts (or Amps) Rated Life This column shows the rated power consumption (watts) of the lamp at its design voltage. A few lamps, in Table 8, are rated in terms of current (amperes) drawn initially at their rated voltage. The watts shown for the lamps in Table 8 are the approximate initial values for operation at rated amperes. Life ratings of Projection Lamps are based on closely controlled laboratory tests of lamps, at their rated voltage, over a long period of production time. Rated Life is not necessarily the same as service life; mechanical shock and vibration, voltage fluctuation, temperature and other environmental factors may result in shorter service life. As with any median value, some individual lamps will operate longer, and some will operate shorter, than their Rated Life. (Supply voltage variation can significantly affect lamp life.) Order Code: It is important to use this five-digit code when ordering to ensure that you receive the exact product you require. Description This is a 3-letter or letter-number code uniquely identifying the lamp for ordering purposes. In some instances, lamps with 3-letter (ANSI) codes are offered in more than one design voltage, in which case the voltage required should also be specified when ordering. Source Size This is defined as the dimensions of the rectangular area, centered on the lamp axis, within which all luminous parts of the filament lie, when viewed perpendicular to the axis of the filament coil or to the plane of C-13 and C-13D filaments. Typical Working Distance For Multi-Mirror® and other reflector Quartzline® lamps and MARC™ lamps, the Working Distance shown is The value shown is based on spherical photometry, at the distance from the front surface of the reflector rim rated voltage, of lamps that have been seasoned for to the film plane, in the optical system for which the approximately 15% (or minimum of 2 hours) or more lamp was first designed. In most cases, it provides a uniform plane of light for the intended aperture. of their rated average life. Initial Lumens Volts Color Temperature The voltage shown is the design voltage of the lamp, on which the life and wattage ratings are based. Lamps are available only in the design voltage(s) shown. When ordering lamps listed for more than one voltage, be sure to specify the voltage required. (Supply voltage variation can significantly affect lamp life.) The radiation within the visible spectrum from tungsten filament lamps is similar in spectral distribution to that from a “blackbody” at specific color temperatures. The Color Temperatures shown are approximate initial values in degrees kelvin (K) for lamps operated at rated voltage. CBCP (Center Beam Candlepower): For reflector type lamps. Center Beam Candlepower is the intensity (candelas) at the center or maximum intensity of the beam. Case Quantity: Operating Position Number of product units packed in a case. For good performance, lamps must be used within specified limitations on operating position. The following abbreviations are used in the lamp tables to indicate these limits: BD = Base Down. Operate only vertical, base down. HD = Base Down to Horizontal. Do not operate base above horizontal. H22 = Operate base down to 22° base up. U = Operate in any position. Filament Typical filament configurations for Projection Lamps are shown on page 8-4, along with an explanation of the filament designation system. Additional Information Typical application and/or other important information. Bulb Shape Base Rated Color Order Case Filament Life Lumens Temp. Burn Watts Code Description Volts Qty. Design MOL LCL Hours Initial K CBCP Position Additional Information Typical Source Working Size Footnote Distance (WxH) QUARTZLINE® MULTI-MIRROR® REFLECTORS MR-16 FACETED DICHROIC REFLECTOR. 2” DIAMETER (51MM). TABLE 3. MR16 GX5.3 2-Pin 150 43537 DDL 20 20 C-6 1.75 500 3150 HD Microfilm DDL ANSI Code. 8-8 For the most up-to-date product information, see www.gelighting.com. All footnote references found at the end of this section (page 8-13). To convert inches to millimeters, multiply by 25.4. A 7.75 Projection Lamps Bulb Shape Base Rated Color Order Case Filament Life Lumens Temp. Burn Watts Code Description Volts Qty. Design MOL LCL Hours Initial K CBCP Position Additional Information Typical Source Working Size Footnote Distance (WxH) QUARTZLINE® MULTI-MIRROR® REFLECTORS MR-11 FACETED DICHROIC REFLECTOR. 1 3⁄8” DIAMETER (35MM). TABLE 1. MR11 GZ4 2-Pin 28 30894 FLS 25261 FLT 12 10 CC-6 13.8 10 CC-6 1.38 1.38 1000 500 3000 3050 HD HD Microfilm Microfilm A A HD HD HD HD HD Slide projection Slide projection Slide projection Color printer. Slide projection A A A A, R A Flood Microfilm Slide projection Microfilm Microfilm Microfilm 8mm projection 8mm projection 8mm projection 8mm projection 16mm, Color printer 8mm projection 8mm projection, fiber optics 8mm projection Microfilm 16mm projection Fiber optics, color printer Fiber optics, color printer Fiber optics, disco Microfilm Slide projection Slide projection Fiber optics, display lighting 8mm projection Overhead projection Overhead projection 8mm projection Fiber optics Microfilm Microfilm Overhead projection Enlarger, projection Enlarger, projection Fiber Optics Overhead projection A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A MR-13 FACETED DICHROIC REFLECTOR. 1 2⁄3” DIAMETER(42MM). TABLE 2. MR13 GX5.3 2-Pin 300 12092 12095 250 12097 225 15832 300 47614 EXR EXW EXY EZF/EZJ FHS 82 82 82 68 82 20 20 20 20 20 CC-8 CC-8 CC-8 CC-8 CC-8 1.75 1.75 1.75 1.75 1.75 35 15 200 350 70 3350 3450 3200 3300 6.00 6.00 6.00 6.00 MR-16 FACETED DICHROIC REFLECTOR. 2” DIAMETER (51MM). TABLE 3. MR16 GX5.3 2-Pin GZ6.35 2-Pin GX5.3 2-Pin GY5.3 2-Pin GX5.3 2-Pin GY5.3 2-Pin GX5.3 2-Pin GY5.3 2-Pin 20 10933 150 43537 80 43206 80 43988 85 43950 50 44854 50 21276 75 21277 100 21278 150 21279 200 29150 150 29151 150 35200 80 35800 200 36899 30 36902 250 37462 250 22023 250 15377 150 38306 300 38476 250 38686 50 25475 80 40248 360 41705 19475 35 41430 42 41729 90 41882 42614 340 41874 150 43756 85 11698 250 11322 250 11110 BAB/PH DDL DDM DDS DED DJT EFM EFN EFP EFR EJL EJM EKE EKP/ENA EKX EKZ ELC ELC/C ELC/500 ELD/EJN ELH ENH ENL ENW/ENC ENX ENX-5 EPN EPT EPV EPX ERV ESD ESJ ETJ EVW 12 20 19 21 13.8 13.8 8 12 12 15 24 21 21 30 24 10.8 24 24 24 21 120 120 12 19 82 86 12 10.8 14.5 14.5 36 120 82 120 82 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 C-6 C-6 CC-6 CC-6 C-6 CC-6 C-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 CC-6 C-6 CC-6 CC-6 CC-6 CC-6 CC-8 CC-8 C-6 CC-6 CC-8 CC-8 C-6 C-6 CC-6 CC-6 CC-8 CC-8 CC-8 CC-8 CC-8 1.88 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 2000 500 50 1000 1000 1000 50 50 50 50 50 40 250 25 25 200 50 50 500 40 35 175 4000 200 75 75 50 10000 500 500 75 12 40 175 50 2900 HD 3150 HD 3350 HD 3125 HD 3150 HD 3150 HD 3300 HD 3350 HD 3350 HD 3350 HD 3400 HD 3350 HD 3250 HD 3350 HD 3400 HD 3100 HD 3400 HD 3400 HD 3350 HD 3350 HD 3350 HD 3250 11700 HD 3050 HD 3200 HD 3300 HD 3300 HD 3300 HD 2900 HD 3150 HD 3150 HD 3300 HD 3350 HD 3350 HD 3300 HD 3300 H22 For the most up-to-date product information, see www.gelighting.com. All footnote references found at the end of this section (page 8-13). To convert inches to millimeters, multiply by 25.4. 5.00 7.75 6.00 6.50 6.50 6.00 1.25 1.25 1.25 1.25 1.25 1.50 1.75 1.75 5.50 1.50 1.25 1.25 1.25 6.50 6.00 6.00 1.50 1.75 11.75 1.13 1.50 6.13 6.50 11.75 1.75 1.75 1.50 11.75 8-9 Projection Lamps Bulb Shape Base Rated Color Order Case Filament Life Lumens Temp. Burn Watts Code Description Volts Qty. Design MOL LCL Hours Initial K CBCP Position Additional Information Typical Source Working Size Footnote Distance (WxH) QUARTZLINE® MULTI-MIRROR® REFLECTORS (CONTINUED) MR-16 FACETED DICHROIC REFLECTOR. 2” DIAMETER (51MM). TABLE 3. (CONTINUED) MR16 GX5.3 2-Pin 100 12003 250 11750 Wire Term. 32 41783 GX5.3 2-Pin 45 23071 GY5.3 2-Pin 150 15477 GX5.3 2-Pin 25 47914 50 14887 GY5.3 2-Pin 410 21613 2-Pin w/LEADS 150 25137 EXV 12 20 EXX 120 20 EZA/4 6.6A 20 EZC 6.6A 20 EZK 120 20 FHX 13.8 20 FML 13.8 20 FXL 82 20 Q150MR 15 20 16-15/LEADS CC-6 CC-8 C-8 C-8 CC-8 CC-6 CC-6 CC-8 C-8 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.88 50 25 1000 1000 200 250 1000 38 150 3100 3350 3100 6750 3300 6750 2900 4500 2950 3200 3600 3200 3150 3300 3400 U U HD HD U HD HD HD HD Camera Light Camera Light Airport Airport Camera Light Microfilm Microfilm Overhead projection A A A A A A A A A 4.13 8.44 11.75 1.75 HD HD HD HD Fiber Optics 8mm proj., printer Fiber Optics 8mm projection A A A A 1.10 1.75 1.50 1.25 QUARTZLINE® REFLECTOR LAMPS MR-16 SMOOTH DICHROIC REFLECTOR. 2” DIAMETER (51MM). TABLE 4. MR16 GX5.3 2-Pin 150 32882 150 32831 80 32886 50 40598 EJA EJV EJY ENZ 21 21 19 30 20 20 20 20 CC-6 CC-6 CC-6 CC-6 1.75 1.75 1.75 1.75 40 40 25 25 3350 3350 3400 3450 MR-14 (1 3⁄4” DIAMETER) OR MR-16 (2” DIAMETER) DICHROIC REFLECTOR. 2-PIN VENTED BASE. TABLE 5. MR14 G7.9 2-Pin MR16 G7.9 2-Pin GX7.9 2-Pin MR14 GX7.9 2-Pin 250 40658 150 40161 150 39742 50 41885 250 40017 BHB 120 DNE 120 DNF 21 ELS/ELR 18 EMM/EKS 24 24 24 24 24 24 CC-8 CC-8 CC-8 CC-8 CC-8 1.67 1.77 1.77 1.41 1.66 25 12 25 650 50 3350 3350 3400 3100 3400 HD HD HD HD HD 16mm projection 8mm projection 8mm projection Microfilm 16mm projection A A A A A 50 3200 HD Slide Projection. A, D 2.63 2.75 2.75 4.75 2.63 QUARTZLINE® SINGLE-ENDED 4-PIN SLIDE PROJECTION. TABLE 6. T6 G17q 4-Pin 500 36178 BCK 120 24 C-13D 3.25 1.56 APPLICATIONS: PROJECTION, MICROFILM, STUDIO, ETC. TABLE 7. T3.5 G6.35 2-Pin G6 G5.3 2-Pin G7 G5.3 2-Pin 2-Button GZ9.5 2-Pin Pf 50 18234 650 30304 600 30364 600 32071 650 33248 33250 600 19479 32955 T3.5 T4 T6 T4 30 37346 150 37695 500 37527 250 14874 175 42612 400 41164 T6 8-10 G5.3 2-Pin GZ9.5 2-Pin Pf GZ9.5 2-Pin Pf G6.35 2-Pin G5.3 2-Pin GY6.35 2-Pin BRL DVY DYH DYP DYR DYR DYS-5 DYS/DYV/ BHC DZA DZE/FDS EHA EHJ EML EVD 12 100 C-6 120 24 CC-6 120 24 CC-6 120 24 CC-6 220 24 2CC-8 240 24 2CC-8 120 24 CC-6 120 24 CC-6 1.72 2.48 2.50 2.25 2.50 2.50 2.50 2.50 1.17 1.44 1.44 1.00 1.44 1.44 1.44 1.44 50 25 75 75 50 50 150 75 1400 20000 17000 17000 16500 16500 15500 17000 3400 3300 3200 3200 3200 3200 3200 3200 U HD U HD U U HD HD A A, E A A A A A A 10.8 24 120 24 24 36 2.00 2.68 3.00 2.25 2.12 2.34 1.06 1.31 1.44 1.31 1.06 1.40 400 530 100 4000 50 50 8000 125 5000 50 14500 3100 3250 3300 3400 3200 3200 HD HD HD HD HD HD A A A, D A A A 24 24 24 100 24 24 C-6 C-6 Oval C-13D C-6 Oval C-6 C-6 Overhead projector For the most up-to-date product information, see www.gelighting.com. All footnote references found at the end of this section (page 8-13). To convert inches to millimeters, multiply by 25.4. .50 x .20 .50 x .25 .50 x .25 .45 x .45 .45 x .45 .45 x .45 .50 x .25 .15 x .05 .25 x .15 .35 x .35 .30 x .15 .21 x .19 Projection Lamps Bulb Shape Base Rated Color Order Case Filament Life Lumens Temp. Burn Watts Code Description Volts Qty. Design MOL LCL Hours Initial K CBCP Position Additional Information Typical Source Working Size Footnote Distance (WxH) QUARTZLINE® SINGLE-ENDED (CONTINUED) APPLICATIONS: PROJECTION, MICROFILM, STUDIO, ETC. TABLE 7. (CONTINUED) T3.5 G5.3 2-Pin 360 12696 19322 G6 G5.3 2-Pin 250 13617 500 33663 T3 GY6.35 2-Pin 100 14876 T4 G6.35 2-Pin 150 13598 T3 GZ9.5 2-Pin Pf 100 35321 T4 G6.35 2-Pin 150 36878 GY6.35 300 19886 Ceramic G6.35 2-Pin 275 18241 T3.5 G5.3 250 80853 EYB EYB-5 EYH/FKT FBG/FBD FCR FCS FDT FDV FLW 82 24 CC-8 2.25 1.25 86 24 CC-8 2.25 1.25 120 24 CC-6 2.50 1.44 120 24 CC-6 3.00 1.75 12 100 C-6 Oval 1.75 1.18 24 100 C-6 Oval 2.00 1.18 12 24 C-6 Oval 2.12 1.06 24 24 C-6 Oval 2.00 1.19 24 48 C-6 Oval 2.15 1.21 75 10000 3300 75 3200 200 6000 3000 50 13200 3200 50 2800 3300 50 4500 3300 50 2900 3300 100 4300 3050 50 10200 3500 HD HD HD U HD HD HD U HD A A A A A A A A A .30 x .20 .30 x .20 .55 x .17 .50 x .20 .20 x .15 .25 x .15 .23 x .15 .25 x .15 .34 x .23 FNT/100 GCA 24 100 C-6 Oval 2.25 1.31 120 12 CC-8 2.24 1.26 50 10000 3400 200 5700 3200 HD U A A .14 x .28 QUARTZLINE® SINGLE-ENDED – AMP RATED. TABLE 8. T4 GZ9.5 2-Pin 120 10099 150 11427 T3.5 GZ9.5 2-Pin 30 11478 45 11482 T4 GZ9.5 2-Pin 200 15243 EVV EWR EXL EXM EZL 6.6A 24 6.6A 24 6.6A 24 6.6A 24 6.6A 24 C-6 Oval C-6 Oval C-8 C-8 C-6 Oval 2.50 2.50 1.75 1.75 2.50 1.54 500 1.54 500 1.00 1000 1.00 1000 1.54 500 3150 4100 375 750 5000 3200 3200 2900 2950 3100 BD BD HD HD BD Airport Airport Airport Airport Airport A A A A A .25 x .12 .25 x .16 .05 x .13 .06 x .19 .28 x .19 U U U U U U U U Overhead Projection Copyboard, Studio Copyboard, Studio Spec. (PH1000H) Printer Overhead Projection Printer Copyboard A A A A A A A A .70 x .21 .90 x .17 .90 x .17 25 9800 3200 30 12500 3200 BD BD Slide Projection Slide Projection. A A, J A, I A, J A, I QUARTZLINE® DOUBLE-ENDED PROJECTION. TABLE 9. T5 T4 R7s R7s T5 T4 R7s R7s 1000 29604 800 36952 36953 1000 38311 420 29581 600 29598 29592 420 30276 BRH DXX DXX ETT FAL FCB FFJ FFM 120 230 240 120 120 120 120 120 24 24 24 24 24 24 24 24 CC-8 CC-8 CC-8 CC-8 CC-8 CC-8 CC-8 CC-8 120 120 24 C-13D 24 C-13D 3.75 3.13 3.13 3.75 2.63 3.75 2.63 3.13 0.50 60 75 75 70 90 120 85 90 30000 3350 21400 3200 21400 3200 3350 11000 3200 17000 3250 17000 3250 11000 3200 .35 x .17 .45 x .18 .60 x .17 .50 x .25 INCANDESCENT PROJECTION 4-PIN BASE. TABLE 10. T10 G17q 4-Pin 400 40214 DAT/DAK 500 29695 DAY/DAK 4.00 1.56 4.00 1.56 4-PIN BASE – PROXIMITY REFLECTOR. TABLE 11. T10 G17q 4-Pin 300 29525 CAL 150 29380 CAR 500 29664 CZA/CZB 120 120 120 24 C-13 24 2CC-8 24 C-13D 4.00 1.56 3.13 1.31 4.00 1.56 25 15 25 3200 3100 3300 BD BD BD T12 G17q 4-Pin 500 29737 DEK/DFW/ 120 DHN 24 C-13D 3.62 1.75 25 3250 HD Slide, Film Strip. Slide, Film Strip. Slide Projection Gold Top (opaque) Slide Projection. A, H, I 4-PIN BASE – FOCUSING REFLECTOR. TABLE 12. T12 GX17q 4-Pin 150 29360 DCA 21 G17q 4-Pin 150 29364 DCH/DJA/ 120 DFP GX17q 4-Pin 80 36122 DFE 30 G17q 4-Pin 150 29386 DFN/DFC 125 24 CC-6 24 CC-6 3.56 1.56 3.38 1.56 15 15 3250 3150 HD BD 8mm Projection. 8mm Projection A, I A 1.75 2.25 24 CC-8 24 CC-8 3.19 1.56 3.19 1.56 15 15 3400 3150 HD HD 8mm Projection 8mm Projection A A 2.25 2.25 For the most up-to-date product information, see www.gelighting.com. All footnote references found at the end of this section (page 8-13). To convert inches to millimeters, multiply by 25.4. 8-11 Projection Lamps Bulb Shape Base Rated Color Order Case Filament Life Lumens Temp. Burn Watts Code Description Volts Qty. Design MOL LCL Hours Initial K CBCP Position INCANDESCENT PROJECTION (CONTINUED) 4-PIN BASE – FOCUSING REFLECTOR. TABLE 12. T14 G17q 4-Pin 150 29338 DJL GX17q 4-Pin 80 40216 DLD/DFZ 150 29366 DLS/DLG/ DHX 120 30 22 24 CC-8 24 CC-6 24 CC-6 Additional Information Typical Source Working Size Footnote Distance (WxH) (CONTINUED) 3.50 1.56 3.50 1.56 3.44 1.56 15 15 15 3150 3400 3250 HD HD HD 8mm Projection 8mm Projection. 8mm Projection. A A, K A, K BD BD BD 8mm Projection. Overhead projection Overhead projection A, J A A Slide Projection Wheel Align Projection. A A, J MEDIUM PREFOCUS BASE. ANSI BASE DESIGNATION: P28/25. TABLE 13. T10 T20 Med. Pref. 500 29677 CZX/DAB Med. Pref. 1000 29968 DRB 29947 DRS 120 118 120 24 C-13D 24 C-13 24 C-13D 5.75 2.19 5.75 2.19 5.75 2.19 25 12500 3200 25 32000 3350 25 28500 3325 SINGLE CONTACT BAYONET BASE. ANSI BASE DESIGNATION: BA15S. TABLE 14. T8 S. C. Bay. 100 29257 CDD 120 43330 CEM 120 120 24 CC-2V 24 2CC-8 3.13 1.38 3.13 1.38 50 200 2000 2975 1950 3000 BD BD DOUBLE CONTACT BAYONET BASE. ANSI BASE DESIGNATION: BA15D. TABLE 15. S11 D. C. Bay. T8 D. C. Bay. T6.4 D.C. Bay. 30 29140 50 29156 75 32137 50 29171 50 29169 75 29208 100 29266 29244 35 30202 25 BLC BLX BNF CAX CAX CBX/CBS CDJ CEB EAJ 118 120 CC-2V 118 120 CC-2V 120 120 CC-2V 118 24 CC-2V 130 24 CC-2V 118 24 CC-13 118 24 CC-2V 118 24 CC-13 12 24 C6 C6 2.38 2.38 2.38 3.13 3.13 3.13 3.13 3.13 4.00 1.38 1.38 1.38 1.38 1.38 1.38 1.38 1.38 1.77 50 50 25 50 50 50 50 50 300 300 400 780 1300 775 775 1200 2000 1850 620 420 2775 2850 2900 2875 2875 2925 2975 2975 U HD HD BD BD BD BD BD U Editor Projection Toy Projection Toy Projection Optical Projection Optical Projection Slide Projection. Slide Projection Slide Projection Flashtube Modeling. A, J A A A, L SINGLE CONTACT PREFOCUS BASE. ANSI BASE DESIGNATION: P30S. TABLE 16. T8 S. C. Pref. 34 30421 BXB 8.5 24 C-8 3.13 1.63 100 690 HD Sound Reproduction. Filament offset 3⁄16” from base axis. 9.06 4.75 50 28000 3200 BD Opaque Projection A 4.94 4.94 4.94 2.25 6.94 6.94 6.00 6.94 20 9000 3200 3 8000 3400 3 5000 4800 50 400 2700 6 17000 3400 6 10500 4800 20 6500 3200 60 13650 3200 U U U U U U U U Photocopy, Inside Frost No. 1 Photoflood, Frost No B1 Blue, Inside Frost Photocopy, Inside Frost No 2, Inside Frost No. B2, Blue, Inside Frost Inside Frost Inside Frost A A A A A A A A MISCELLANEOUS. TABLE 17. T20 Mogul 1000 29959 DPT 120 12 C-13 PHOTOFLOOD STANDARD. TABLE 18. A21 Medium S11 Cand. PS25 Medium A23 Medium PS25 Medium 8-12 300 40886 250 40563 40564 30 30232 500 40566 40567 250 40565 500 40568 BAH BBA BCA BLK EBV EBW PH/B2 ECA ECT 115 24 C-9 118 24 C-9 118 24 C-9 125 120 CC-2V 118 24 C-9 118 24 C-9 120 24 C-9 120 24 C-9 For the most up-to-date product information, see www.gelighting.com. All footnote references found at the end of this section (page 8-13). To convert inches to millimeters, multiply by 25.4. 1.75 1.75 1.75 Projection Lamps Bulb Shape Base Rated Color Order Case Filament Life Lumens Temp. Burn Watts Code Description Volts Qty. Design MOL LCL Hours Initial K CBCP Position Additional Information Typical Source Working Size Footnote Distance (WxH) PHOTOFLOOD (CONTINUED) REFLECTOR. TABLE 19. R40 Medium 500 30151 DXB 30145 DXC 30281 EAL 120 120 120 24 CC-2V 24 C-9 24 CC-2V 6.63 6.63 6.63 6 6 15 2.38 3.38 4.94 4.94 4.94 15 35 65 100 3 3300 45000 3300 5500 3200 6800 Spot Beam, 15 degrees. A, Q Flood Beam, 90 degrees. A, Q Medium Beam, 60 degrees. A, Q ENLARGER & PRINTER. TABLE 20. S11 S14 A21 S.C. Bay. Medium Medium 75 30162 75 43220 75 40569 150 40570 250 40571 PH/111A PH/140 PH/211 PH/212 PH/213 125 120 120 120 120 120 120 24 24 24 1120 1150 1000 2300 7000 2900 2900 3000 3050 3400 HD U U U U Enlarger, White Enlarger, White Enlarger, White Enlarger, White Enlarger, White A A A A A 125000 6000 U Graphic Arts A, B 240000 2200 6000 5000 U Graphic Arts BDTH Light Engine, Medical BDTH Light Engine, Medical BDTH Light Engine, Medical H Replaces MARC 300/16A. A, B A, S A, S A, S A, O 1.46 H A, O 2.05 PULSED XENON ARC, GEMINI®, AND MARC™. TABLE 21. T3 WireTerm/ 4000 30124 Ceramic 8000 30129 T11 Special 175 29376 300 46909 300 10115 PAR20 Special 300 11134 2-Pin Plug PAR24 Special 350 39936 2-Pin Plug PXA 50 6 4.63 PXA/80 CXE175/BF 12 CXE300/BF/SB 14 CXE300/BF 14 GEMINI 35 300(EZG) MARC 45 350-16T EZT 6 4 4 4 4 4.63 1.67 1.67 1.67 4 1000 1000 1000 75 50 6000 5600 350000 5600 500000 5600 500000 6000 50 5000 POWER SUPPLY TO OPERATE GEMINI® AND MARC™ LAMPS For information on the special power supply used to operate these lamps, contact: Scientecular Lab Company 98 McKinney Avenue Central Islip, NY 11722-4120 (516) 232-3345 NAPS/Fortron Source 328 Ley Road, Suite 300 Ft. Wayne, IN 46808 (219) 471-1368 Fax: (219) 471-1368 WARNING AND CAUTION NOTICES A S WARNING Risk of electrical shock • Turn power off before inspection,installation or removal Risk of fire • Keep combustible material away from lamp • Use in enclosed fixtures rated for this product Pressurized lamp-unexpected rupture may cause injury, fire, or property damage • Do not exceed 110% of rated voltage • Avoid direct water/liquid contact • Use in enclosed fixtures rated for this product • Do not use lamp if outer glass is scratched or broken CAUTION Risk of burn • Allow lamp/fixture to cool before handling • Turn off power before installing lamp Lamp may shatter and cause injury if broken • Do not use lamp if outer glass is scratched or broken • Dispose of lamp in enclosed container WARNING Lamp emits UV radiation which may cause eye/skin irritation. RG-3 • Avoid exposure of eyes and skin to unshielded lamp CAUTION Lamp may shatter and cause injury if broken • Wear safety glasses and gloves when handling lamp • Do not use excessive force when installing lamp FOOTNOTES # Footnote B Pulsed Xenon lamps emit high levels of ultraviolet (UV) radiation and must be completely enclosed in an inter-locked system with all walls made of UV absorbing material. The lamp must be made inoperative before the system is opened. The operator or user should never be exposed to the high level of UV radiation emitted by PXA lamps. C Opaque Ceramic top on bulb. D Proximity Reflector. E Ultraviolet absorbing bulb. G Heat resistant glass bulb. H Collector grid. I Gold Top (opaque). J Black Top (opaque). K Dichroic reflector. L Two-filament lamp. M Filament offset 3 3⁄16” from base axis. O Should not be operated for periods of less than three minutes. Q Approximate beam spread to 1⁄2 center-beam intensity. R Red-enhanced dichroic filter. For the most up-to-date product information, see www.gelighting.com. All footnote references found at the end of this section (page 8-13). To convert inches to millimeters, multiply by 25.4. 8-13 Projection Lamps NOTES \ 8-14 For the most up-to-date product information, see www.gelighting.com. All footnote references found at the end of this section (page 8-13). To convert inches to millimeters, multiply by 25.4. n /- £ Ó - Appendix £ { Î { x È Ç /n £ Ó Î { £ £ä ££ /£Ó £Î £{ £x ,£È £Ç Ó LAMP SIZE/DIAMETER £n £ The diameter of a lamp, at its maximum dimension, is expressed in eighths of an inch. Examples: The diameter of an A19 lamp is 19-eighths of an inch, or 23⁄8", at its widest point. A T8 lamp has a diameter of 8-eighths, or one inch. *,Óä Ó£ ÓÓ LIGHT CENTER LENGTH (L.C.L.) ÓÎ Î Óx ÓÈ Ón Ó ,Îä Σ { ÎÎ Î{ Îx *,ÎÈ ÎÇ *,În x {Î Location All Screw Bases (except Mini-Can.) ...................................................... Bottom of base contact Mini-Can ................................Where diameter of ceramic base insulator is .531 inches 3-Contact Medium..............................................................................Bottom of base contact Mogul Medium Prefocus ...................................................................................Top of base fins Mogul Prefocus .....................................................................................................Top of base fins Medium BiPost.................................................................................Base end of bulb (Glass lamps) ..............................................................................................Bottom of ceramic base (Quartz lamps) Mogul BiPost .......................................................................... Shoulder of posts (Glass lamps) .........................................................................................Bottom of ceramic base (Quartz lamps) 2-Pin Prefocus.....................................................................................Bottom of ceramic base. S.C. or D.C. Bayonet Candelabra ................................................................. Top of base pins Medium Bayonet ................................................................................................ Top of base pins S.C. or D.C. Prefocus .................................... Plane of locating bosses on prefocus collar Medium 2-Pin ................................................................................. Bottom of metal base shell MAXIMUM OVERALL LENGTH (M.O.L.) {{ {x The end-to-end measurement of a lamp, expressed in inches or millimeters. *,{È {Ç È IMPORTANT NOTICE This catalog is a compilation of accumulated data. Additional information is constantly being uncovered through research and testing, which may modify the data given herein. This is particularly true of newer lamps and ballasts. Accordingly, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. For the latest lamp and ballast design data and information, contact your GE Representative. { xä x£ *-xÓ xÎ x{ xx Ç xÇ xn x Èä È£ ÈÓ ÈÎ *,È{ Èx The distance between the center of the filament, or arc tube, and a reference plane — usually the bottom of the lamp base. See L.C.L. Reference Plane Location chart below. L.C.L. Reference Plane Location Base Type ÓÇ Î ,{ä] {ä {£ {Ó LAMP SIZING GUIDE n The data and suggested applications contained in this catalog, as well as any additional information our representative may be able to furnish, are for general information only and are not intended and should not be taken as representations or warranties as to the suitability of a lamp or ballast for any particular application or use in any particular equipment, nor are our representatives authorized to make any such warranties. Applications and conditions of use are many and varied, and beyond our control. We cannot possibly have the same degree of knowledge that the purchaser has with respect to the design of his equipment and the conditions of its use. Therefore, it is up to the purchaser to make his own determination as to the suitability of a lamp or ballast for his intended application or use and to assume the responsibility for that determination. General Electric desires to supply the best possible products at all times. For this reason, General Electric reserves the right to make changes in its products, and to introduce new products or discontinue existing ones without notice. ÈÈ ÈÇ Èn È Çä Ç£ ÇÎ Ç{ Çx ÇÈ ÇÇ Çn Ç APPENDIX LISTINGS: Lamp Sizing Guide ......................................................................................................................... A-1 Sales and Customer Service Offices–U.S. and Canada ................................................ A-2 Glossary of Terms........................................................................................................................... A-3 Cost of Light–Reducing Lighting Costs................................................................................. A-9 Selecting the Best Color Lamp ...............................................................................................A-10 £ä A-1 Appendix GE LIGHTING U.S. AND CANADIAN SALES OFFICES AND CUSTOMER SERVICE CENTERS US Sales Offices OEM and Specialty Lighting Area Sales Offices Phone/Fax No. Eastern p. 216 266-2121 Southeast Specialty p. f. p. f. p. f. p. f. 860 747-7094 860 747-7849 908 203-6527 908 231-6391 856 317-5228 856 317-5236 973 256-8956 973 256-4350 Southeast OEM 980 Washington St., Ste. 332N p. Dedham, MA 02026 f. 20 Technology Pkwy. p. Norcross, GA 30092 f. Charlotte 4601 Park Rd., Ste. 400 p. Charlotte, NC 28209 f. Birmingham 31 Inverness Center Pkwy., Ste. 500 p. Birmingham, AL 35242 f. 781 320-4256 781 320-4245 770 662-4979 770 447-7218 803 462-2016 803 462-2017 205 408-9902 205 408-9903 Rocky Mt & West Coast Tampa Region/States Location Address GE Lighting Headquarters Nela Park, 1975 Noble Rd. Cleveland, OH 44112 Eastern Plainville 41 Woodford Ave. Plainville, CT 06062 NY, NJ New York 34 West Rt. 22 Branchburg, NJ 08876 NJ, East PA Cherry Hill 535 Rt. 38 East Cherry Hill, NJ 08002 NJ,, NY, DE Wayne 155 Rt. 46 West Wayne, NJ 07470 MA, RI, VT, Boston NH, ME, CT Southeast Atlanta NC, SC AL, GA FL 4300 West Cypress Ste. 700 Tampa, FL 33607 Central Cleveland 1975 Noble Rd., Bldg. 335F Cleveland, OH 44112 DC, MD, VA Washington 7272 Park Circle Dr., Ste. 300 Hanover, MD 21076 TN, KY Memphis 1760 Moriah Woods Blvd., Ste. 9 Memphis, TN 38117 Cent OH Columbus 4079 Executive Pkwy., Ste. 310 Westerville, OH 43081 So OH, KY Cincinnati 10101 Alliance Rd., Ste. 135 Cincinnati, OH 45242 p. f. p. f. p. f. p. f. p. f. p. f. 813 910-0086 813 972-9382 216 266-8358 216 266-5580 410 737-7212 410 737-7216 901 762-4332 901 762-4336 614 899-8931 614 899-8908 513 936-6591 513 936-6599 IN Indianapolis 12722 Hamilton Cross Blvd. Carmel, IN 46032 Chicago 701 E 22nd St., Ste. 300 Lombard, IL 60148 Milwaukee 400 N Executive Dr., Ste. 300 Brookfield, WI 53005 p. f. p. f. p. f. 317 574-1577 317 574-1970 630 652-4400 630 652-4486 262 797-4946 262 797-4917 Detriot p. 248 262-2762 f. 248 262-2856 Midwest WI, IA MI, NW OH Two Towne Square Southfield, MI 48076 Southwest Dallas PO Box 610847 1717 West Airfield Dr. Dallas, TX 75261-0847 CO, WY Denver 2000 S. Colorado Blvd., Ste. 100 Denver, CO 80222 KS, MO, OK Kansas City 10550 Barkley St., Ste. 200 Overland Park, KS 66212 LA, MS, AR New Orleans 201 Evans Rd., Ste. 200 Harahan, LA 70123 South TX West Houston 3530 W. 12th St., Ste. 100 Houston, TX 77008 Los Angeles 3191 Temple Ave., Ste. 200 Pomona, CA 91768 p. f. p. f. p. f. p. f. 972 574-0548 972 574-0561 303 464-2823 303 464-2879 913 967-6373 913 967-6378 504 731-5540 504 731-5535 p. f. p. f. 713 880-7496 713 880-7493 909 444-5230 909 444-5227 CANADIAN OFFICES 2728 Hopewell Place NE, p. 403 214-4435 Calgary, Alberta T1Y 7J7 f. 403 214-4772 Montreal, Quebec 555 Dr.Frederick-Philips Blvd. 3rd FL. p. 514 215-2740 St. Laurent, Quebec H4M 2X4 f. 514 215-2795 Oakville, Ontario 468 South Service Rd. East p. 877 259-0941 Oakville, Ontario L6J 2X6 f. 905 849-2911 Vancover, BC #100-8525 Baxter Place p. 604 451-3216 Burnaby, BC V5A 4V7 f. 604 451-3241 In addition to the Sales Offices in the cities listed above, GE Lamp Sales Representatives are resident in other cities. Consult your local telephone directory under GE Lighting. Midwest Southwest Central Southwest Specialty West Specialty Canada OEM Canada Specialty Automotive p. f. p. f. p. f. p. f. p. f. p. f. p. f. p. f. p. f. p. f. p. 212 575-6067 212 575-6605 678 762-0808 678 393-0919 901 762-4323 901 762-4336 630 652-4427 630 652-4486 817 427-3969 817 485-7396 972 444-2021 817 485-7396 480 836-2469 480 836-2322 714 501-5905 909 305-4662 905 849-2903 905 849-2911 905 469-6070 905 469-6637 248 262-2754 To Order Product US/Canada Current Customer Ordering and Tracking - www.geelitenet.com Customer Service Center OEM Automotive OEM Commercial & Industrial Distributors Consumer & Retail Canada (French/English) Telephone 1-800-544-4680 1-800-327-7155 1-800-327-0097 1-800-327-2080 1-800-443-4925 Facsimile 1-800-544-4830 1-800-327-0588 1-800-544-4830 1-800-544-4850 1-800-443-4930 Telesales OEM C&I Midwest C&I Central C&I Northeast C&I West C&I Southeast C&I Southwest Canada Telephone 1-800-544-4780 1-800-624-0601 1-866-355-6210 1-800-327-7085 1-800-443-6272 1-800-544-4610 1-800-624-0601 1-800-443-5081 Facsimile 1-800-327-0663 1-800-327-0663 1-800-327-0663 1-800-327-0663 1-800-327-0663 1-800-327-0663 1-800-327-0663 1-800-327-0663 Distribution Centers Atlanta Chicago Dallas Hagerstown Los Angeles Oakville Ravenna 1700 Westgate Pkwy., Atlanta, GA 30336 7770 West 71st St., Bridgeview, IL 60455 1717 West Airfield Dr., PO Box 610847, DFW Airport, TX 75261 18212 Shawley Dr., Hagerstown, MD 21740 11600 Philadelphia Ave., Mira Loma, CA 91752 1290 South Service Rd. West, Oakville, Ontario, Canada L6L 5T7 150 Loomis Pkwy., Ravenna, OH 44266 Lighting Technical Information Consumer Inquiries Commercial, Trade Magazines 1-800-GE LIGHT (435-4448) 1-800-GE LAMPS (435-2677) International Customer Service and Sales (USA Exporters Only) Calgary, Alberta A-2 251 Avenue of Americas 7th Floor, New York, NY 10020 625 S. Preston Ct. Alpharetta, GA 30022 1760 Moriah Woods Blvd., Ste. 9 Memphis, TN 38117-7128 701 East 22nd St., Ste. 300 Lombard, IL 60148 1717 West Airfield Dr. Dallas, TX 75261-4014 741 Spring Valley Dr. Hurst, TX 76054 15334 Golden Eagle Blvd. Fountain, AZ 85268 571 Rider Ct. Claremont, CA 91711 468 South Service Rd. East Oakville, Ontario L6J 2X6 468 South Service Rd. East Oakville, Ontario L6J 2X6 Two Towne Square Southfield, MI 48076 Franchise Exporters International Customers Phone Number 1-800-327-6886 1-804-965-1015 Fax Number 1-800-443-5130 1-804-965-1018 For Lamp or Technical Support Call or Click 1-800-GE LAMPS www.GELighting.com Appendix GLOSSARY OF TERMS Ambient Temperature Candlepower Light output of fluorescent lamps depends on ambient temperature which refers to the temperature INSIDE the fixture in the air surrounding the fluorescent lamp. An obsolete term for luminous intensity; current practice is to refer to this simply as candelas. See Candela. Amperes Candlepower Distribution Curve (“Amps.”) A measure of electrical current. In incandescent lamps, the current is related to voltage and power as follows: Current (Amps) = Power (Watts) / Voltage (Volts). A graphical presentation of the distribution of light intensity of a light source, usually a reflector lamp or luminaire. American National Standards Institute (ANSI) Cathode see electrode A consensus-based organization which coordinates voluntary standards for the physical, electrical and performance characteristics of lamps, ballasts, luminaires and other lighting and electrical equipment. Center Beam Candlepower (CBCP) ANSI Ballast Type A reference to the ANSI document describing the lamp which also lists the characteristics of the ballast required to operate the lamp. The following naming system is used: H - mercury lamps; M - metal halide lamps; S - high pressure sodium lamps; L - low pressure sodium lamps. Ballast An auxiliary piece of equipment required to start and to properly control the flow of current to gas discharge light sources such as fluorescent and high intensity discharge (HID) lamps. Ballast Factor (BF) This is the percentage of a lamp’s rated lumen output that can be expected when operated on a specific, commercially available ballast. For example, a ballast with a ballast factor of 0.93 will result in the lamp’s emitting 93% of its rated lumen output. A ballast with a lower BF results in less light output and also generally consumes less power. Ballast Losses Power or energy dissipated in the ballast as heat and not converted to lamp energy. Beam Angle The angular dimension of the cone of light from reflectorized lamps (such as R and PAR types) encompassing the central part of the beam out to the angle where the intensity is 50% of maximum. The beam angle sometimes called “beam spread” is often part of the ordering code for reflectorized lamps. Example: The 50PAR30/HIR/ NFL25 is a 50 watt PAR30 narrow flood lamp with a beam angle of 25 degrees. See also Field Angle. Beam Lumens The total lumens present within the portion of the beam contained in the beam angle. Biax ® GE trademark for its biaxial family of high-efficiency and long-life compact fluorescent lamps. DBX (Double Biax) TBX (Triple Biax) and QBX (Quad Biax) refer to the number of U-shaped legs present in the lamp. Canadian Standards Association (CSA) An organization that writes standards and tests lighting equipment for performance as well as electrical and fire safety. Canadian provincial laws generally require that all products sold for consumer use in Canada must have CSA or equivalent approval. Candela (cd) The measure of luminous intensity of a source in a given direction. The term has been retained from the early days of lighting when a standard candle of a fixed size and composition was defined as producing one candela in every direction. A plot of intensity versus direction is called a candela distribution curve and is often provided for reflectorized lamps and for luminaires with a lamp operating in them. Refers to the luminous intensity at the center of the beam of a blown or pressed reflector lamp (such as a PAR lamp). Measured in candelas. See also Candela. Ceramic Metal Halide (CMH ®) A type of metal halide lamp that uses a ceramic material for the arc tube instead of glass quartz, resulting in better color rendering (>80 CRI) and improved lumen maintenance. GE ConstantColor® CMH® lamps feature a 3-piece arc tube design that delivers terrific color consistency and lamp reliability. ChromaFit ® A GE brand name for metal halide lamps designed to operate on HPS ballasts, allowing a user to switch from the yellowish color of HPS to the white color of metal halide without retrofitting ballasts. These products are available in both quartz metal halide and ceramic metal halide (CMH) versions. Coefficient of Utilization (CU) In general lighting calculations, the fraction of initial lamp lumens that reach the work plane. CU is a function of luminaire efficiency, room surface reflectances and room shape. Color Rendering Index (CRI) An international system used to rate a lamp’s ability to render object colors. The higher the CRI (based upon a 0-100 scale) the richer colors generally appear. CRI ratings of various lamps may be compared, but a numerical comparison is only valid if the lamps are close in color temperature. CRI differences among lamps are not usually significant (visible to the eye) unless the difference is more than 3 -5 points. Color Temperature (Correlated Color Temperature - CCT) A number indicating the degree of “yellowness” or “blueness” of a white light source. Measured in kelvins, CCT represents the temperature an incandescent object (like a filament) must reach to mimic the color of the lamp. Yellowish-white (“warm”) sources, like incandescent lamps, have lower color temperatures in the 2700K - 3000K range; white and bluish-white (“cool”) sources, such as cool white (4100K) and natural daylight (6000K), have higher color temperatures. The higher the color temperature the whiter, or bluer, the light will be. Compact Fluorescent Lamp (CFL) The general term applied to fluorescent lamps that are single-ended and that have smaller diameter tubes that are bent to form a compact shape. Some CFLs have integral ballasts and medium or candelabra screw bases for easy replacement of incandescent lamps. ConstantColor ® A GE registered name for lamp families that show very little color shift over life, such as GE’s Precise ® MR16 lamps and GEs ceramic metal halide (CMH®) lamps. Cost of Light Usually refers to the cost of operating and maintaining a lighting system on an ongoing basis. The 88-8-4 rule states that (typically) 88% is the cost of electricity, 8% is labor and only 4% is the cost of lamps. A-3 Appendix GLOSSARY OF TERMS CovRGuard ® Electronic HID Ballast A lamp encased by a sleeve made of the highest quality GE Lexan® plastic and sealed using a patented process. The Lexan covering helps contain glass fragments if the lamp breaks. An electronic ballast capable of operating an HID lamp. GE’s Ultramax® (electronic HID ballast operates Pulse Arc® (metal halide) and CMH® (ceramic metal halide) lamps between 250W and 400W and provides higher efficiency and significantly improved lumen maintenance over magnetic ballasts. Diamond Precise ® Diamond Precise® is the GE trade name for its line-voltage MR16 ConstantColor® halogen lamp. An integral ballast and a medium screw base enable Diamond Precise® lamps to operate on standard (120 volt) circuits. The MR16 technology of Diamond Precise® allows a tighter, more intense beam than can be attained by the 50-watt PAR20 and R20 types it’s designed to replace, even though the lumen output is significantly less by comparison. Discharge Lamp A lamp where light is emitted from an electrical discharge between two electrodes as opposed to a filament lamp. Examples are: Fluorescent lamps and HID (High Intensity Discharge) lamps like Metal Halide, Mercury and High Pressure Sodium. All discharge lamps require some kind of current-limiting device, e.g. a ballast to operate them. Ecolux ® Elliptical Reflector (ER) Lamp An incandescent lamp with a built-in elliptically-shaped reflecting surface. This shape produces a focal point directly in front of the lamp which reduces light absorption in some types of luminaires. It is particularly effective at increasing the efficiency of baffled downlights. Enclosed Fixtures Energy Policy Act (EPACT) Comprehensive energy legislation passed by the U.S. Congress in 2005. The lighting portion includes minimum energy efficacy requirements for many lamp and ballast components, bans ballasts for mercury lamps from 2008 on and provides significant tax incentives in 2006 and 2007 for buildings retrofitted or constructed with low lighting power densities (watts per square foot). A term for GE lamps that pass the TCLP test. See TCLP. Edison GE’s trademark for a wide range of lighting products. Efficacy See Luminous Efficacy. e-HID ballast see Electronic HID Ballast Electrode In a discharge lamp the arc is struck between two protruding metal terminals in the chamber. These are called electrodes. The negative electrode which emits electrons to fuel the electrical discharge is called the cathode. Electrodeless Lamp See Induction Lighting and GENURA®. Electromagentic Ballast See Magnetic Ballast. Electromagnetic Spectrum A continuum of electric and magnetic radiation that can be characterized by wavelength or frequency. Visible light encompasses a small part of the electro-magnetic spectrum in the region from about 380 nanometers (violet) to 770 nanometers (red) by wavelength. Electromagnetic Interference (EMI) High frequency electronic ballasts and other electronic devices can produce a small amount of radio waves that can interfere with radio and TV. Federally-mandated requirements must be met for EMI levels before an electronic device is considered FCC compliant. (FCC is the Federal Communications Commission) Electronic Ballast A short name for a fluorescent or HID high frequency electronic ballast. Electronic ballasts use solid state electronic components and typically operate fluorescent lamps at frequencies in the range of 25-35 kHz. The benefits are: increased lamp efficacy, reduced ballast losses and lighter, smaller ballasts compared to electromagnetic ballasts. Electronic ballasts may also be used with HID lamps. A-4 Energy Star® US Department of Energy (DOE) designation for products meeting certain energy efficiency and performance standards. Among manufacturers of Compact Fluorescent Lamps, GE has the largest number of Energy Star® products as listed on the Federal Government’s website. EOL (End-of-Life Protection) A circuit that senses that a lamp has reached end of life (compact fluorescent lamps and small diameter linear fluorescent lamps) and turns off power to the lamp. Continuing to power the lamp beyond end of life can result in overheating of the lamp ends. Federal Communications Commission (FCC) The U.S. Federal agency that regulates emissions in the radio frequency portion of the electromagnetic spectrum. Part 18 of the FCC rules specifies electromagnetic interference (EMI) from lighting devices operating at frequencies greater than 9 kilohertz (kHz.). Typical electronically-ballasted compact fluorescent lamps operate in the 24 – 100 kHz frequency range. Field Angle The angular dimension of the cone of light from reflectorized lamps (such as R and PAR types) encompassing the central part of the beam out to the angle where the intensity is 10% of maximum. See Beam Angle. Fluorescent HO And VHO lamps require special ballasts that generate higher currents than standard ballasts and operate the lamps at higher wattage than standard lamps. These lamps are generally less efficient than the standard product. Metal Halide HO and XHO lamps operate on the same ballasts as standard lamps and at the same wattage but are more efficient and produce higher light output than standard lamps. Fluorescent Lamp A high efficiency lamp utilizing an electric discharge through low pressure mercury vapor to produce ultra-violet (UV) energy. The UV excites phosphor materials applied as a thin layer on the inside of a glass tube which makes up the structure of the lamp. The phosphors transform the UV to visible light. Footcandle (fc) A unit of illuminance or light falling onto a surface. It stands for the light level on a surface one foot from a standard candle. One footcandle is equal to one lumen per square foot. See also Lux. Appendix Full Spectrum Lighting Ignitor A marketing term, typically associated with light sources that are similar to some forms of natural daylight (5000K and above, 90+ CRI), but sometimes more broadly used for lamps that have a smooth and continuous color spectrum. An electronic device providing a high voltage pulse to initiate an electrical discharge. Typically, the ignitor is paired with or is a part of the ballast. Genura® GE’s electrodeless compact fluorescent lamp, Genura®, uses induction to power the discharge. The chamber generates UV (just like a discharge in a regular fluorescent lamp) that is converted by phosphors to visible light. Because Genura® uses no electrodes, the life of this unique reflector lamp is longer than typical compact fluorescent products. See Induction Lighting. Glare Visual discomfort caused by excessive brightness is called discomfort glare. If task performance is affected it is called disability glare. Glare can be direct glare or indirect (reflected) glare. Halogen Lamp A halogen lamp is an incandescent lamp with a filament that is surrounded by halogen gases, such as iodine or bromine. Halogen gases allow the filaments to be operated at higher temperatures and higher efficacies. The halogen participates in a tungsten transport cycle, returning tungsten to the filament and prolonging lamp life. All halogen lamps have a tungsten filament and, often, a quartz envelope. Halogen-IR ® (HIR) Lamp GE designation for high-efficiency tungsten halogen lamps. HIR lamps utilize shaped filament tubes coated with numerous layers of materials that transmit light but reflect the heat (infrared) back onto the filament. This reduces the power needed to keep the filament hot. Harmonic Distortion see Total Harmonic Distortion (THD) Illuminance The “density” of light (lumens/area) incident on a surface; i.e. the light level on a surface. Illuminance is measured in footcandles or lux. Incandescent Lamp A light source that generates light utilizing a thin filament wire (usually of tungsten) heated to white heat by an electric current passing through it. Indirect Lighting The method of lighting a space by directing the light from luminaires upwards towards the ceiling. The light scattered off the ceiling produces a soft, diffuse illumination for the entire area. Induction Lighting Gases can be excited directly by radio-frequency or microwaves from a coil that creates induced electromagnetic fields. This is called induction lighting and it differs from a conventional discharge, which uses electrodes to carry current into the arc. Induction lamps have no electrodes inside the chamber and generally, therefore, have longer life than standard lamps. Genura® is an example of an induction lamp. Infrared Radiation Electromagnetic energy radiated in the wavelength range of about 770 to 1,000,000 nanometers. Energy in this range cannot be seen by the human eye, but can be sensed as heat by the skin. Input Watts, Input Volts Unit of frequency of vibration, denoting cycles per second. These refer to the ballast: the input watts represents the total power consumption of the ballast. It includes the power to the lamps and the power dissipated in the ballast. The input volts of the ballast is the line voltage the ballast is designed for, e.g. 120 volts or 277 volts. Highbay Lighting Instant Start Lighting designed for (typically) industrial locations with a ceiling height of 25 feet and above. A type of ballast designed to start fluorescent lamps as soon as the power is applied. Most T8 fluorescent lamps are being operated on electronic instant-start ballasts. Slimline fluorescent lamps operate only on instant start circuits. Hertz High-Intensity Discharge (HID) Lamp A general term for mercury, metal halide (GE ConstantColor® CMH®, Multi-Vapor®, MXR or Arcstream®) and high-pressure sodium (GE Lucalox®) lamps. HID lamps contain compact arc tubes which enclose various gases and metal salts operating at relatively high pressures and temperatures. Kelvins see Color Temperature High Output/Very High Output (HO, VHO) Lamps Kilowatt Hour (kWh) Designation for lamps generating more light than standard lamps. High-Pressure Sodium (HPS) Lamp HPS lamps are high intensity discharge light sources that produce light by an electrical discharge through sodium vapor operating at relatively high pressures and temperatures. GE markets these lamps under the trade name of Lucalox ®. Hot Restart Time If there is a momentary power interruption and the HID lamp goes out, there will be a delay of 10 to 15 minutes before the lamp has cooled down sufficiently to start again. This is called the Hot Restart time. PulseArc® lamps have a significantly shorter Hot Restart time (typically 3-5 minutes) than standard metal halide lamps. Lucalox® Standby lamps will start up immediately while standard Lucalox® lamps require a few minutes. Kilowatt (kW) A measure of electrical power equal to 1000 watts. The standard measure of electrical energy and the typical billing unit used by electrical utilities for electricity use. A 100-watt lamp operated for 10 hours consumes 1000 watt-hours (100 x 10) or one kilowatt-hour. If the utility charges $.10/kWh, then the electricity cost for the 10 hours of operation would be 10 cents (1 x $.10). Lamp The term used to refer to the complete light source package, including the inner parts as well as the outer bulb or tube. “Lamp”, of course, is also commonly used to refer to a type of small light fixture such as a table lamp. Life See Rated Lamp Life. A-5 Appendix GLOSSARY OF TERMS (CONTINUED) Light Lux (lx) Radiant energy that can be sensed or seen by the human eye. Visible light is measured in lumens. A unit of illuminance or light falling onto a surface. One lux is equal to one lumen per square meter. Ten lux approximately equals one footcandle. See also Footcandle. Light Center Length (L.C.L.) Magnetic Ballast The distance between the center of the filament, or arc tube, and a reference plane — usually the bottom of the lamp base. See L.C.L. Reference Plane Location chart on page A-1. A ballast used with discharge lamps that consists primarily of transformer-like copper windings on a steel or iron core. See also Electronic Ballasts. Light Emitting Diode (LED) Maximum Overall Length (M.O.L.) A solid that directly converts electrical impulses into light. Some LED’s today incorporate fluorescent materials to change the color characteristics of the emitted light. The end-to-end measurement of a lamp, expressed in inches or millimeters. Mean Lumens The product of all factors that contribute to lowering the illumination level including reflector degradation, dirt, lamp depreciation over time, voltage fluctuations, temperature effects, burn-out factor, etc. The average light output of a lamp over its rated life. Based on the shape of the lumen depreciation curve, for fluorescent and metal halide lamps, mean lumens are measured at 40% of rated lamp life. For mercury, high pressure sodium and incandescent lamps, mean lumen ratings refer to lumens at 50% of rated lamp life. See Lumen Maintenance. Lucalox ® Mercury Lamp The GE brand name for high-pressure sodium lamps. A high-intensity discharge light source operating at a relatively high pressure (about 1 atmosphere) and temperature in which most of the light is produced by radiation from excited mercury vapor. Phosphor coatings on some lamp types add additional light and improve color rendering. Light Loss Factor (LLF) Lumen A measure of luminous flux or quantity of light emitted by a source. For example, a dinner candle provides about 12 lumens. A 60-watt Soft White incandescent lamp provides 840 lumens. Lumen Depreciation, Lumen Maintenance A measure of how well a lamp maintains its light output over time. It may be expressed numerically or as a graph of light output vs. time. Lumens Per Watt (lpW) A ratio expressing the luminous efficacy of a light source. Typical lamp efficacies: Edison’s first lamp ...................................................................................................... 1.4 lpW Incandescent lamps ..................................................................................................... 10-40 Halogen incandescent lamps .................................................................................. 20-45 Fluorescent lamps .......................................................................................................35-105 Mercury lamps ................................................................................................................ 50-60 Metal halide lamps ......................................................................................................60-120 High-pressure sodium lamps .................................................................................60-140 Note: The values above for discharge lamps do not include the effect of the ballasts, which must be used with those lamps. Taking ballast losses into account reduces “system” or lamp ballast efficacies typically by 10-20% depending upon the type of ballast used. Luminaire A complete lighting unit consisting of a lamp (or lamps), ballast (or ballasts) as required together with the parts designed to distribute the light, position and protect the lamps and connect them to the power supply. A luminaire is often referred to as a fixture. Luminaire Efficiency The ratio of total lumens emitted by a luminaire to those emitted by the lamp or lamps used in that luminaire. Luminance A photometric measure of “brightness” of a surface as seen by the observer, measured in candelas per square meter. Luminous Efficacy The light output (lumens) of a light source divided by the total power input (watts) to that source. It is expressed in lumens per watt. See Lumens per Watt. A-6 Metal Halide Lamp A high-intensity discharge light source in which the light is produced by the radiation from mercury, plus halides of metals such as sodium, scandium, indium and dysprosium. Some lamp types may also utilize phosphor coatings. GE trade names include: Multi-Vapor ®, ConstantColor® CMH®, PulseArc®, Staybright®, Watt-Miser®, ChromaFit® and Arcstream®. Mortality Curve Lamps have a rated or expected life but individual failures occur earlier and some lamps will last longer. The mortality curve depicts the expected percent surviving in a group of lamps at various points between zero hours and rated life or beyond. The curve starts with 100% at zero hours and goes to 50% surviving at the rated life (e.g. 3000 hours or 20,000 hours, etc.) However, the shape of the curve between these two end points can vary depending on the lamp type. Multi-Vapor® Multi-Vapor® A GE brand name for metal halide lamps. Nanometer A unit of wavelength equal to one billionth of a meter. National Electric Code (NEC) A nationally accepted electrical installation code to reduce the risk of fire, developed by the National Fire Protection Association. PAR Lamp PAR is an acronym for parabolic aluminized reflector. A PAR lamp, which may utilize either an incandescent filament, a halogen filament tube or a HID arc tube, is a precision pressed-glass reflector lamp. PAR lamps rely on both the internal reflector and prisms in the lens for the control of the light beam. Appendix Parallel Lamp Operation/Parallel Wiring Reflector Lamp (R) Refers to ballasts that employ multiple output current paths from a single ballast to allow lamps to operate independent of one another, allowing other lamps operated by the ballast to remain lit should companion lamp(s) fail. (See Series Lamp Operation). A light source with a built-in reflecting surface. Sometimes, the term is used to refer specifically to blown bulbs like the “R” and “ER” lamps; at other times, it includes all reflectorized lamps like PAR and MR. Phosphor Reveal ® An inorganic chemical compound processed into a powder and deposited on the inner glass surface of fluorescent tubes and some mercury and metal-halide lamp bulbs. Phosphors are designed to absorb short wavelength ultraviolet radiation and to transform and emit it as visible light. GE’s product family of incandescent lamps with the element Neodymium added to the glass bulb. Neodymium filters out much of the yellow light produced by ordinary lamps. Less yellow means whites look whiter and colors appear more vibrant in spaces lighted with Reveal lamps. Photometry Scotopic/Photopic (S/P) Ratio The measurement of light and related quantities. This measurement accounts for the fact that of the two light sensors in the retina, rods are more sensitive to blue light (Scotopic vision) and cones to yellow light (Photopic vision). The Scotopic/Photopic (S/P) Ratio is an attempt to capture the relative strengths of these two responses. S/P is calculated as the ratio of scotopic lumens to photopic lumens for the light source on an ANSI reference ballast. Cooler sources (higher color temperatures lamps) tend to have higher values of the S/P Ratio compared to warm sources. Photopic see Scotopic/Photopic Power Factor (PF) A measure of the phase difference between voltage and current drawn by an electrical device, such as a ballast or motor. Power factors can range from 0 to 1.0 with 1.0 being ideal. Power factor is sometimes expressed as a percent. Incandescent lamps have power factors close to 1.0 because they are simple “resistive” loads. The power factor of a fluorescent and HID lamp system is determined by the ballast used. “High” power factor usually means a rating of 0.9 or greater. Power companies may penalize users for using low power factor devices. Refers to ballasts that employ a single current path passing through all lamps operated by the ballast. If one lamp should fail, companion lamps operated by the same ballasts will also extinguish or dim. Precise ® Specification Series (SP) Colors The GE trade name for the compact MR-16 and MR-11 low-voltage halogen dichroic cool beam reflectorized spot and flood lamps. Preheat Circuit A type of fluorescent lamp-ballast circuit used with the first commercial fluorescent lamp products. A push button or automatic switch is used to preheat the lamp cathodes to a glow state. Starting the lamp can then be accomplished using simple “choke” or reactor ballasts. Programmed Rapid Start see UltraStart PulseArc ® GE description for a type of metal halide lamp that provides improved lumen maintenance for longer useful life and extended relamp cycles. These products are designed to operate on ballasts that have ignitors to help with lamp starting. Quartz-Halogen Lamp see Halogen Lamp Quartzline ® A GE registered trademark term for some types of halogen lamps. Rapid Start Circuit A fluorescent lamp-ballast circuit that utilizes continuous cathode heating, while the system is energized, to start and maintain lamp light output at efficient levels. Rapid start ballasts may be either electromagnetic, electronic or of hybrid designs. Full-range fluorescent lamp dimming is only possible with rapid start systems. Rated Lamp Life For most lamp types, rated lamp life is the length of time of a statistically large sample between first use and the point when 50% of the lamps have died. It is possible to define “useful life” of a lamp based on practical considerations involving lumen depreciation and color shift. Series Lamp Operation Energy-efficient, all-purpose tri-phosphor fluorescent lamp colors that provide good color rendering. The CRI for SP colors is 70 or above and varies by specific lamp type. See Lamp Color Chart on page A-10. Specification Series Deluxe (SPX) Colors Energy-efficient tri-phosphor fluorescent lamp colors that provide better color rendering than Specification Series (SP) colors. The CRI for SPX colors is 80 or higher and varies by specific lamp type. All GE CFL products use SPX phosphors. See Lamp Color Chart on page A-10. Spectral Power Distribution (SPD) A graph of the radiant power emitted by a light source as a function of wavelength. SPD’s provide a visual profile or “finger print” of the color characteristics of the source throughout the visible part of the spectrum. Spiral ® Lamp GE trademark for its helical family of high-efficiency, long-life compact fluorescent lamps. Starcoat ® GE’s special barrier coating applied on the inside of all GE T8 fluorescent lamps, as well as some other lamp types, to enhance lamp life and deliver superior lumen maintenance. Starting Temperature (Minimum) The minimum ambient temperature at which the lamp will start reliably on the ballast. TCLP Test The Toxicity Characteristic Leaching Procedure (TCLP) test, specified in the Resource Conservation and Recovery Act (RCRA) of 1990, is used to characterize fluorescent lamp waste as hazardous or nonhazardous waste. The TCLP test measures the ability of the mercury and/or lead in a lamp to leach from a landfill into ground water. A-7 Appendix GLOSSARY OF TERMS (CONTINUED) Total Harmonic Distortion (THD) Ultra Watt-Miser ® A measure of the distortion of the input current on alternating current (AC) power systems caused by higher order harmonics of the fundamental frequency (60Hz in North America). THD is expressed in percent and may refer to individual electrical loads (such as a ballast) or a total electrical circuit or system in a building. ANSI C82.77 recommends THD not exceed 32% for individual commercial electronic ballasts, although some electrical utilities may require lower THD’s on some systems. Excessive THD’s on electrical systems can cause efficiency losses as well as overheating and deterioration of system components. GE’s family of energy-saving T8 fluorescent lamps. Troffer Underwriter’s Lab (UL) A private organization which tests and lists electrical and other equipment for electrical and fire safety standards. Generally luminaires are UL listed, not lamps (except for CFL lamps with built-in ballasts.) Voltage A measurement of the electromotive force in an electrical circuit or device expressed in volts. Voltage can be thought of as being analogous to the pressure in a waterline. A long, recessed lighting unit, usually installed in an opening in the ceiling. Tungsten Halogen Lamp see Halogen Lamp Voltage Surge Ultra Transient spikes in line voltage that can be harmful to electronic equipment like computers and electronic ballasts. Surge suppressors are often used to protect against such transients. GE designation for lamps and ballasts belonging to the new generation of energysaving fluorescent systems. Warm-up Time UltraMax ® The designation for GE's electronic ballasts for both linear fluorescent systems and for HID systems (see "Electronic HID Ballast"). The family of high-efficiency GE instant-start electronic linear fluorescent ballasts are designed to optimize GEs T8 Ultra lamps for enhanced system energy savings. UltraMax ballasts have a low lamp current crest factor and virtually read and adapt to incoming voltage from 108V to 305V. Other features include UL Type CC Anti-Arc Rating and anti-striation control to eliminate lamp striations and spiraling. UltraStart GE’s line of Programmed Rapid Start ballasts, for both T8 and T5 lamps, made specifically for applications where lamps are switched on and off frequently. The “ultra soft” starting associated with these ballasts ensures long lamp life even in frequently switched applications. Additional features include high efficiency and start times comparable to Instant Start ballasts, and series operation of lamps. Ultraviolet (UV) Radiation For practical purposes, any radiant energy within the range of 100-380 nanometers. It is beyond the blue or violet region of the spectrum, and is invisible to the eye just like the silent “ultrasound” dog whistle is inaudible to the ear. UV is divided into 3 regions: UVA ..................................................................................................................... 100 to 280 nm UVB ..................................................................................................................... 280 to 315 nm UVC ..................................................................................................................... 315 to 400 nm Some wavelengths (180-220) produce ozone, some (220-300) are bactericidal, some (280-320) erythemal (redden human skin); others (320-400) cause secondary luminance (black light). A-8 HID lamps typically take a few minutes to warm-up to full brightness after starting. Watt A unit of electrical power. Lamps are rated in watts to indicate the rate at which they consume energy. See Kilowatt Hour. Watt-Miser ® A Watt-Miser® lamp is a term used by GE to indicate a reduced-wattage lamp with performance characteristics (life, light output, etc.) such that it can usually directly replace a higher-wattage product. Watt-Miser® lamps are available in a wide range of incandescent, fluorescent and HID lamp types. Appendix ’Lectricity 88% ELECTRICITY IS THE BIGGEST CHUNK OF YOUR LIGHTING COSTS Labor 8% Averaging across different lamp types and systems, we estimate that only $1 of every $25 goes toward lamps, $2 toward labor, and $22 toward electricity! The simplest way to save energy is to retrofit with energy-efficient products and systems from GE Lighting: your #1 energy-saving choice! And remember… every watt reduced in your lighting system results in a one-third watt reduction in your A/C load (while A/C is running). Lamps 4% <EA#D aTca^UXccTSfXcW <EA"%BC1F< bPeTb'_Ta UXgcdaTX] T]TaVh^eTa cWT[XUT^U cWT[P\_ 4PRW5"!C'aT_[PRTS fXcWP]5"!C'F< bPeTb"!_Ta[P\_ X]T]TaVh^eTacWT[XUT ^UcWT[P\_ 4]TaVhBPeX]V4gP\_[Tb Pbbd\X]V#$W^dab _TahTPa _TaZFW P]STgR[dSX]V02bPeX]Vb 4PRW#[P\_C !UXgcdaTaTca^UXccTSfXcW 64{b[PcTbcD[caP<PgbhbcT\bPeTb!& _TahTPaX]T]TaVhR^bcbfXcW]TPa[hcWT bP\T[XVWc^dc_dc"aTSdRcX^]X][d\T]b) C !F<^]bcP]SPaS\PV]TcXRQP[[PbcebC' ^]&&15T[TRca^]XRX]bcP]cbcPacQP[[Pbc 4PRW(F?0AWP[^VT][P\_ aT_[PRTSfXcWP&F?0A78A [P\_fX[[bPeT(_TahTPaX] T]TaVhR^bcbfXcW]TPa[hcWT bP\T[XVWc^dc_dc #aTSdRcX^] X][d\T]b 4PRW F X]RP]STbRT]c Qd[QaT_[PRTS fXcWP!%F25; fX[[bPeT"" _TahTPa _Tab^RZTc X]T]TaVh R^bcb REDUCE LABOR COSTS WITH PLANNED MAINTENANCE/GROUP RELAMPING Schedule your lighting maintenance instead of simply waiting for lamps to fail! In any large installation, failure rates increase with age in a predictable way. The optimal point for group relamping is typically when 8% to 12% of lamps have failed, usually around two-thirds of rated life. At this point, both lumen output and lamp color may have deteriorated, yet the cost of electricity remains at “full price.” The per-lamp labor cost of installing new lamps is usually significantly less when an entire site is relamped, compared to the per-lamp labor cost of replacing lamps one at a time. The result? The facility gets a face-lift and the maintenance costs over the next two or three years are generally significantly reduced. Contact your GE Account Manager or GE Distributor to understand the full benefits of planned maintenance and to get set up on a money-saving group relamping schedule. A-9 Appendix selecting the best BETTER COLOR RENDERING FOR BETTER APPEARANCE DESCRIPTIONS: “WARM” OR “COOL” When talking about white light sources (or about white paint) we use the descriptions “warm” and “cool.” White light with a yellowish tinge, reminiscent of candlelight and fireplaces, is called “warm white.” Incandescent lamps produce a warm white color. Bluish white, reminiscent of moonlight on cold snow, is considered “cool white.” Fluorescent lamps can produce warm white or cool white, or anywhere in-between, depending on the mix of phosphors used. CORRELATED COLOR TEMPERATURE (CCT) Correlated Color Temperature is a way of describing the degree of “yellowness” or “blueness” of a white light source. We relate the light source to the color of a hypothetical piece of hot metal. A piece of steel or tungsten as it is heated, will progressively change color in the sequence shown below: Cherry Red Bright Red Orange Yellow Yellowish White White Bluish White Hotter = Higher Color Temperature When we say a lamp has a color temperature of 2700K—typical of incandescent lighting—it simply means that a piece of metal heated to a temperature of 2700 kelvins (which is about 3000°C or 5400°F) would mimic the color of the lamp. Such a source would be yellowish-white. In contrast, the color of a lamp at 6000K—typical of daylight entering through a window on a sunny day—can be mimicked by doubling the temperature of the hot metal piece to 6000 kelvins. This is significantly bluer or “cooler” than the light of incandescent lamps. Note that higher CCT refers to sources described as “cooler.” Generally, 4000K and above is considered “cool white”, 3200K and below is “warm white”, and 3500K is “neutral white.” There is no such thing as the “true” color of any material; the perceived color is a function of the light under which the material is viewed and the reflectance characteristics of the material itself. However, we can make a general statement: the higher the Color Rendering Index (CRI) of a light source (also denoted by Ra) the better—and more natural—colors typically appear under the light source. In measuring CRI, scientists compare how eight specific colors appear under the source to how these same colors appear under a reference source. However, there are two reference sources: incandescent lighting is the reference for warm color lamps and daylight is the reference for cool color lamps. In this system, both incandescent lamps and daylight are considered to have “perfect” CRI’s of nearly 100 even though, as we know, materials appear quite different when viewed under these light sources. These two sources are very different in color temperature (see below) although both have CRI’s close to 100. CRI is, therefore, meaningful in comparing lamps that are close in color temperature. CRI is not a perfect measure, but it is still useful as an indicator of the quality of light from a source. Typical Color Indicators for Various Lamps Correlated Color Temperature INCANDESCENT LAMPS Typical 2500-2800K HALOGEN LAMPS Typical 2800-3000K FLUORESCENT LAMPS (ordered by CCT) C75 “Chroma Series” 7500K SPX65 (865) 6500K SP65 (765) 6500K C50 “Chroma Series” 5000K SPX50 (850) 5000K SP50 (750) 5000K SPX41 ( 841) 4100K SP41 (741) 4100K Cool White 4100K SPX35 (835) 3500K SP35 (735) 3500K SPX30 (830) 3000K 3000K SP30 (730) Warm White 3000K covRfresh 2750K SPX27 (827) 2700K Color Rendering Index 97-100 97-100 90 + 80 + 70 + 90 + 80 + 70 + 80 + 70 + 62 80 + 70 + 80 + 70 + 50 87 80 + Note: Some 4' T8 "SP" lamps, including reduced wattage types, may have a CRI >80. HIGH PRESSURE SODIUM LAMPS Lucalox® Deluxe Lucalox® METAL HALIDE LAMPS Standard and PulseArc® MVR Multi-Vapor® MXR Multi-Vapor® Arcstream® Multi-Vapor® ChromaFit™ CERAMIC METAL HALIDE LAMPS CMH® CMH® ChromaFit™ A-10 1900-2100K 2200K 22 65 3000-4300K 3200-3500K 3000-6000K 4000-4500K 65-75 65-70 75-90 65-70 3000-4200K 3000K 80-93 85 ">
Advertisement